NIAGARA Niagara Blower Heat Transfer Solutions
|
|
- Walter Sanders
- 7 years ago
- Views:
Transcription
1 NIAGARA Niagara Blower Heat Transfer Solutions No-Frost No-Frost refrigeration and liquid desiccant dehumidification specializes in the food, beverage, laboratory testing, and cold storage industries.
2 Industries Served General Specifications What is No-Frost? Desiccant concentration determines moisture removal capacity. Three different No-Frost liquid formulas are available: LV 50 through 40 F Ethylene glycol based Low viscosity No-Frost refrigeration applications KV 5 through 55 F -grade Propylene glycol based No-Frost refrigeration and dehumidification applications No-Frost technology is ideal for processing, packaging, and storage applications where consistent, frost free conditions are required. Hygrol 30 through 75 F Water treatment plant Triethylene glycol based Dehumidification applications No-Frost systems are comprised of sprayed coil or structured packing conditioner(s) and liquid concentrator(s). Laboratories Baking Dairy Meat & Poultry Distillation Column Concentrator (DCC) All units are custom fabricated to withstand the toughest environments Applications Freezers Frozen Glycol based refrigeration defrost Glycol based liquid desiccant dehumidification Maintains a sanitary, frost-free coil Permanently inhibits 99.9% of airborne pathogens Liquid desiccant absorbs moisture from air stream Heavy duty bolted construction Casing panel options: carbon steel, stainless steel, or fiberglass ASME/ANSI code design Interior parts readily accessible for inspection and cleaning Packaged and field-erected units available Spiral freezer Control panel Niagara can provide: Meat processing Field surveys Engineering design New components Retrofit manufacturing Piping layouts Wiring diagrams Contractor management Complete controls Piping & instrumentation diagrams Commissioning Finned cooling coil Refrigerant flows through finned evaporator coil tubes Desiccant mixture drenches tubes Air is induced over sprayed evaporator coil
3 Industries Served General Specifications What is No-Frost? Desiccant concentration determines moisture removal capacity. Three different No-Frost liquid formulas are available: LV 50 through 40 F Ethylene glycol based Low viscosity No-Frost refrigeration applications KV 5 through 55 F -grade Propylene glycol based No-Frost refrigeration and dehumidification applications No-Frost technology is ideal for processing, packaging, and storage applications where consistent, frost free conditions are required. Hygrol 30 through 75 F Water treatment plant Triethylene glycol based Dehumidification applications No-Frost systems are comprised of sprayed coil or structured packing conditioner(s) and liquid concentrator(s). Laboratories Baking Dairy Meat & Poultry Distillation Column Concentrator (DCC) All units are custom fabricated to withstand the toughest environments Applications Freezers Frozen Glycol based refrigeration defrost Glycol based liquid desiccant dehumidification Maintains a sanitary, frost-free coil Permanently inhibits 99.9% of airborne pathogens Liquid desiccant absorbs moisture from air stream Heavy duty bolted construction Casing panel options: carbon steel, stainless steel, or fiberglass ASME/ANSI code design Interior parts readily accessible for inspection and cleaning Packaged and field-erected units available Spiral freezer Control panel Niagara can provide: Meat processing Field surveys Engineering design New components Retrofit manufacturing Piping layouts Wiring diagrams Contractor management Complete controls Piping & instrumentation diagrams Commissioning Finned cooling coil Refrigerant flows through finned evaporator coil tubes Desiccant mixture drenches tubes Air is induced over sprayed evaporator coil
4 Industries Served General Specifications What is No-Frost? Desiccant concentration determines moisture removal capacity. Three different No-Frost liquid formulas are available: LV 50 through 40 F Ethylene glycol based Low viscosity No-Frost refrigeration applications KV 5 through 55 F -grade Propylene glycol based No-Frost refrigeration and dehumidification applications No-Frost technology is ideal for processing, packaging, and storage applications where consistent, frost free conditions are required. Hygrol 30 through 75 F Water treatment plant Triethylene glycol based Dehumidification applications No-Frost systems are comprised of sprayed coil or structured packing conditioner(s) and liquid concentrator(s). Laboratories Baking Dairy Meat & Poultry Distillation Column Concentrator (DCC) All units are custom fabricated to withstand the toughest environments Applications Freezers Frozen Glycol based refrigeration defrost Glycol based liquid desiccant dehumidification Maintains a sanitary, frost-free coil Permanently inhibits 99.9% of airborne pathogens Liquid desiccant absorbs moisture from air stream Heavy duty bolted construction Casing panel options: carbon steel, stainless steel, or fiberglass ASME/ANSI code design Interior parts readily accessible for inspection and cleaning Packaged and field-erected units available Spiral freezer Control panel Niagara can provide: Meat processing Field surveys Engineering design New components Retrofit manufacturing Piping layouts Wiring diagrams Contractor management Complete controls Piping & instrumentation diagrams Commissioning Finned cooling coil Refrigerant flows through finned evaporator coil tubes Desiccant mixture drenches tubes Air is induced over sprayed evaporator coil
5 Rooftop installation No-Frost Advantages Consistent temperature Consistent dew point Low energy usage Low operating & maintenance costs Asset protection Noncorrosive desiccant liquid Eliminates mold and bacteria Quick recovery from wash down Ensures uninterrupted production Air stream is sanitized/deodorized No-Frost desiccant spray arrangement
6 How Does No-Frost Work? Niagara local representative: About Niagara Blower Heat Transfer Solutions Headquartered in Buffalo, NY, Niagara has proudly provided engineered solutions for heat transfer applications at process, power, refining, and food & beverage facilities worldwide since Niagara boasts a fully equipped laboratory, test facility, ASME code certified factory, custom manufacturing capabilities, and over 100 years of proven success. Niagara product lines include Wet Surface Air Coolers, "No-Frost" refrigeration/dehumidification systems, and Kathabar salt based dehumidification systems. NIAGARA Niagara Blower Heat Transfer Solutions 673 Ontario St., Buffalo, NY Phone: (716) ~ Fax: (716) sales@niagarablower.com /
A Comprehensive Laboratory Test to Analyze the Compatability of Leading Cleaners and Sanitizers on Today's Industrial Refrigeration Evaporator Coils.
Technical Bulletin 430 A Comprehensive Laboratory Test to Analyze the Compatability of Leading s and Sanitizers on Today's Industrial Refrigeration Evaporator Coils. RESEARCH & DEVELOPMENT The EVAPCO Research
More informationA discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.
A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities. Richard L. Dornfeld, BSME, P.E. Staff Engineer September 25, 2014 Moisture can be a problem
More informationHow To Understand Evaporator
SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES After studying this unit, the reader should be able to Define high-, medium-, and low-temperature refrigeration.
More informationTotal Heat Versus Sensible Heat Evaporator Selection Methods & Application
Total Heat Versus Sensible Heat Evaporator Selection Methods & Application Scope The purpose of this paper is to provide specifying engineers, purchasers and users of evaporators in industrial refrigeration
More informationThermochemical Storage for Air-Conditioning using Open Cycle Liquid Desiccant Technology
Thermochemical Storage for Air-Conditioning using Open Cycle Liquid Desiccant Technology E. Laevemann, M. Peltzer, A. Hublitz, A. Kroenauer, U. Raab, A. Hauer Bavarian Center for Applied Energy Research
More informationWhy is my air conditioner dripping on my customers?
De-Mystifying HVAC Why is my air conditioner dripping on my customers? By Ron Prager One of the most frequent emergency service requests is a call for an air conditioner leaking water into the store. These
More informationAutomobile Air Conditioning Primer
Automobile Air Conditioning Primer An air conditioner is basically a refrigerator without the insulated box. It uses the evaporation of a refrigerant, like Freon, to provide cooling. The mechanics of the
More information164,491 SF Food Production Facility Situated on 10 Acres Available in
164,491 SF Food Production Facility Situated on 10 Acres Available in Buffalo, New York CONSTRUCTION Acid resistant brick and coated floors in the production area with drains; clear ceiling heights from
More informationAluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03
Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03 Aluminum Cooling Coil Nomenclature 4 C X C B 0 3 6 C C 3 C U A A Refrigerant Type 4 - R410A Product Family T-Premium (Heat Pump or Convertible
More informationChilled Water HVAC Systems
Chilled Water HVAC Systems By Ron Prager, Brinco Mechanical Services, Inc. Types of water based systems: There are three types of HVAC systems that utilize water as a heat transfer medium. The first system,
More informationNational Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction
More informationCONDENSATION IN REFRIDGERATED BUILDINGS
CONDENSATION IN REFRIDGERATED BUILDINGS By: Steve Salisbury Nov. 10, 2010 (revised Nov. 14, 2013) Introduction The following discussion reviews the basic causes of condensation in refrigerated buildings
More informationInnovent LASER Packaged Fresh Air Conditioning Units
LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent
More informationWhat is LEED? Why pursue LEED accreditation? How does LEED accomplish these goals? Sustainable sites Water efficiency Energy and Atmosphere
Green AAON for What is LEED? Sustainability and green have recently become terms used within the building industry (and others) to refer to a construction project that has low environmental impact, or
More informationHow much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.
Demystifying HVAC Test Your HVAC Knowledge By Ron Prager How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page. 1)
More informationCooling Systems 2/18/2014. Cooling Water Systems. Jim Lukanich, CWT ChemCal, Inc. Grapevine, TX
Cooling Systems Jim Lukanich, CWT ChemCal, Inc. Grapevine, TX Cooling Water Systems Water is used for cooling because of its capacity to remove and store heat and availability. Cooling water is used in
More informationBy Tom Brooke PE, CEM
Air conditioning applications can be broadly categorized as either standard or critical. The former, often called comfort cooling, traditionally just controlled to maintain a zone setpoint dry bulb temperature
More informationDEFROSTING. Service Engineers Section Technical Bulletin No 3
Service Engineers Section Technical Bulletin No 3 DEFROSTING 1. INTRODUCTION This bulletin is presented to cover the methods used and problems experienced with defrosting of coils for chill and frozen
More informationHeating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
More informationCOIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.
COIL INPUT SCREENS Example of a Water Coil Input Screen: (*please see the appendix for an example of an Evaporator, Steam or Condenser Coil input screen) PHYSICAL DATA ITEM NUMBER: Always use a 1 through?
More informationTroubleshooting Your Refrigerator
Troubleshooting Your Refrigerator With conscientious care, a refrigerator will perform for years with little or no repairs. Refrigerators are categorized according to the way frost is removed from them.
More informationHeating Ventilation and Air Conditioning Diagnostics for Single Family Homes
Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes Vincent Pedalino FSL Home Improvements Phoenix, AZ 1 HVAC Basics Ways to improve the performance of existing air conditioning
More informationSTEAM STERILIZERS FOR THE LIFE SCIENCES MADE IN THE USA
STEAM STERILIZERS FOR THE LIFE SCIENCES MADE IN THE USA We Listen to Your Needs For over 35 years R-V Industries, Inc. has partnered our engineering and manufacturing expertise with customer ideas to produce
More informationMeasuring The Right Thing For Humidity Control It s the Dew Point Stupid!
Page 1 of 6 Measuring The Right Thing For Humidity Control It s the Dew Point Stupid! By Mike Schell, AirTest Technologies Corp. A version of this article appeared in the June 2004 edition of Indoor Air
More informationThe Different Types of Air Conditioning Equipment for IT Environments
The Different Types of Air Conditioning Equipment for IT Environments By Tony Evans White Paper #59 Executive Summary Cooling equipment for an IT environment can be implemented in 10 basic configurations.
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationNational Grid Small Business Energy Efficiency Program Overview. Central New York Energy Expo March 30, 2010
National Grid Small Business Energy Efficiency Program Overview Central New York Energy Expo March 30, 2010 Agenda National Grid Cooler Retrofit Program Refrigeration 101 Smart Thermostat Controls, Anti-Sweat
More informationLIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air. Trevor Wende Vice President, Marketing Advantix Systems, Inc.
LIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air Trevor Wende Vice President, Marketing Advantix Systems, Inc. 0 Humidity: The Hidden Cost Driver Conventional A/C process Start
More informationsolarplus solar systems general features
SOLARPLUS solar systems solarplus Applications: expansion vessels for solar systems Zilmet, an internationally operating company with over 50 years of experience has grown to be the biggest European producer
More informationContents and Nomenclature
DX Coils Contents and Nomenclature Nomenclature... 1 Evaporator Coil Types EN... 2 EF... 2 ER... 2 EJ... 3 EK... 3 Evaporator Construction Connections... 4 Tubing... 4 Headers... 5 Tube Supports... 5 Coil
More informationDehumidification Frequently Asked Questions
Dehumidification Basics Why do you want to keep indoor Rh between 30-60%? ASHRAE recommends keeping the relative humidity in a home between 30-60% to limit the effects of many unwanted conditions and harmful
More informationSECTION 11 78 13 MORTUARY REFRIGERATORS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in
More informationSECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
More informationGlossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
More informationSondex Welded heat exchangers:
Sondex A/S is a Danish company specialized in the development, design and production of plate heat exchangers and freshwater distillers. Since its foundation in 1984 SONDEX has grown into a wide global
More informationSECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences
More informationCOURSE TITLE : REFRIGERATION AND AIR CONDITIONING COURSE CODE : 4029 COURSECATEGORY : A PERIODS/WEEK : 5 PERIODS/SEMESTER : 90 CREDITS : 4 OBJECTIVES
COURSE TITLE : REFRIGERATION AND AIR CONDITIONING COURSE CODE : 4029 COURSECATEGORY : A PERIODS/WEEK : 5 PERIODS/SEMESTER : 90 CREDITS : 4 TIME SCHEDULE MODULE TOPICS PERIODS 1 Introduction 22 Principles
More informationLocal Dealer: www.cebrands.com
Local Dealer: C.E. LLC - Miami, FL USA www.cebrands.com Res2012-Rev2 QUALITY YOU CAN FEEL Residential Product Line >TCA7,9 Tempstar SmartComfort TXT + Air Conditioner Featuring The Observer Communication
More informationDefining Quality. Building Comfort. Heating and Cooling Coils
Defining Quality. Building Comfort. Heating and Cooling Coils Heating and Cooling Coils Heating and Cooling Coils For over 20 years, AAON has supplied the coil needs of industrial and commercial HVAC customers.
More informationAnswers to Your Questions from the Webinar
2008 Desert Aire and USA Swimming. Used by permission. Desert Aire & USA Swimming - Aquatics Webinar - Answers to Your Questions Answers to Your Questions from the Webinar Thank you for your interest in
More informationM SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A
Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000
More informationMoisture Control. It s The Dew Point. Stupid! Its not the humidity.
Moisture Control Its not the humidity. It s The Dew Point Stupid! Mike Schell EpiphanyTec Inc. Santa Barbara, CA mschell@epiphanytec.com 805 687-3175 Matching great technology to market need! Topics SHR
More informationDECISION-MAKING TREE FOR DISASTER RECOVERY SOLINET Preservation Services
DECISION-MAKING TREE FOR DISASTER RECOVERY SOLINET Preservation Services (FAST!) Vacuum Dry Coated (FAST!) Paper Uncoated Water-Soluble Inks Large Quantity Thaw & Air-Dry Water-Stable Inks Air-Dry Small
More informationCold Room & Refrigeration System (Casserole Assembly) No of units: 1
Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency
More informationCHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS
CHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS Natural gases either from natural production or storage reservoirs contain water, which condense and form solid gas hydrates to block pipeline flow
More informationFLASH TANK ECONOMIZER PRODUCT GUIDE
FLASH TANK ECONOMIZER PRODUCT GUIDE Overview A flash tank is used to recover blowdown energy in the form of flash steam and blowdown. This can only be used with a deaerator or some other pressurized device.
More informationCreating the Ideal Environment for Accelerated Drying Times on Construction and Restoration Projects
4.02.08 updated Creating the Ideal Environment for Accelerated Drying Times on Construction and Restoration Projects Moisture Removal Systems www.groundheaters.com www.wackerneuson.com Controlling moisture
More informationIncreasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas
Increasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas Mark Schiffhauer, ATSI Engineering Services Cameron Veitch, Combustion and Energy Systems Scott Larsen, New York State Energy
More information2015 CARNOT REFRIGERATION CO 2 PROJECTS IN DATA CENTRES, COMMERCIAL AND INDUSTRIAL REFRIGERATION CASE STUDIES
2015 CARNOT REFRIGERATION CO 2 PROJECTS IN DATA CENTRES, COMMERCIAL AND INDUSTRIAL REFRIGERATION CASE STUDIES STATE OF THE INDUSTRY GUIDE TO NATURAL REFRIGERANTS IN NORTH AMERICA 2015 1 CO 2 transcritical
More informationCONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2
WASTE HEAT BOILERS CONTENTS 1 INTRODUCTION... 3 2 CONCEPTION OF WASTE HEAT BOILERS... 4 2.1 Complex Solution...4 2.2 Kind of Heat Exchange...5 2.3 Heat Recovery Units and Their Usage...5 2.4 Materials
More informationHVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget
A PRIMER Educational HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget Contents: Introduction: The best HVAC system is durable, reliable
More informationGLYCOL CHILLER SYSTEM TROUBLESHOOTING 101
GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101 By Jim VanderGiessen Jr, Pro Refrigeration Inc. There is a good chance your glycol chiller system is often completely forgotten about, until that dreaded day you
More informationFailure code manual. content
Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一
More informationEvaporative Cooling. Terminology. Date: February 28, 2012. Concepts
Evaporative Cooling Date: February 28, 2012 P R E S E N T E D B Y R O B E R T P A D G E T E 3 M S E N G I N E E R E D M E C H A N I C A L S Y S T E M S Concepts 1. Evaporation is a cooling process. Using
More informationSECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
More informationMechanical Rooftop Custom Capabilities
Mechanical Rooftop Custom Capabilities Mechanical Construction Capabilities Price manufactures a wide range of custom gas heat and DX cooled units to meet your new construction and retrofit needs. In addition
More informationMAC-120HE-01 Air-Cooled Chiller
MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01
More informationLIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air
LIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air 0 Optimal Air Quality: Critical to Hotels Provides comfortable environment for guests no overcooling Protects building, carpets
More informationFrost. On Air-Cooling Evaporators. refrigeration applications at temperatures below freezing. These heat exchangers
The following article was published in ASHRAE Journal, February 2009. Copyright 2009 American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. It is presented for educational purposes
More informationTHE POWER OF COLD Antistaseos 2A Tel: 22575231 Kyriacos@ret.com.cy 2034, Strovolos Mob: 99622425 www.sunchill.net Heat activated absorption refrigeration cycles can be used for heat pumping Free Air Conditioning
More informationengineering quality Heat Transfer Specialists Since 1928 service delivery
engineering quality superb service, knowledge of the industry, quality assurance, trusted resource your ideas, our engineering & manufacturing capabilities, solve your heat transfer needs Heat Transfer
More informationPool Dehumidification Basics
Copyright 2009 Wescor. All rights reserved. Permission granted to reproduce for personal and educational use only. When energy costs were low, many pool owners considered only first cost when choosing
More informationCalculating System Flow Requirements
Calculating System Flow Requirements To select a pump, we need to know the flow rate (the amount of fluid to be pumped) and the system resistance or head. In the U.S., flow rates are given in gallons per
More informationGreen Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment
Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment The heating, ventilation and cooling loads of typical commercial office space can range
More informationTHE CASE FOR A REFRIGERATION PREVENTATIVE MAINTENACE PROGRAM
THE CASE FOR A REFRIGERATION PREVENTATIVE MAINTENACE PROGRAM Prepared and Presented By: Don Langston President & CEO, Aire Rite Air Conditioning & Refrigeration Inc Setting the Foundation The Refrigeration
More informationTable Z. Troubleshooting Chart for Air Conditioners. Cause
Troubleshooting Chart for Air Conditioners Type of Unit Complaint Cause With open-type compressor Electric motor will not start Power failure Check circuit for power source Compressor stuck Locate cause
More informationGround Source Heat Pumps The Fundamentals. Southington, Connecticut 860 628 4622 John F. Sima III P.E.
Ground Source Heat Pumps The Fundamentals Southington, Connecticut 860 628 4622 John F. Sima III P.E. Winter/Spring 2010 Ground Source Heat Pumps The Fundamentals TOPICS: Heat Pump Terminology Basic Physics
More informationAir Conditioner Maintenance
Central air conditioning systems are wonderful features of many homes in the US. In hot and humid climates it s hard to imagine living without AC, although this convenience has been common in only the
More informationThermoSorb Desiccant Dryers
ThermoSorb Desiccant Dryers Sierra Why dry compressed air? Contamination reduces efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. During the compression
More informationASME Packaged Indirect Fired Water Heater
Utilizes Or HTHW To Heat Domestic Water, Semi-Instantaneous or Storage Type Model BW Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining
More informationSYLLABUS FOR SIX MONTHS - FULL TIME CERTIFICATE COURSE IN REFRIGERATION AND AIR-CONDITIONING. Effective From :- UNDER DEVELOPMENT.
SYLLABUS FOR SIX MONTHS - FULL TIME CERTIFICATE COURSE IN REFRIGERATION AND AIR-CONDITIONING Effective From :- UNDER DEVELOPMENT Prepared by: Curriculum development cell Institute of Research Development
More informationSWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
More informationHow does solar air conditioning work?
How does solar air conditioning work? In a conventional air conditioning system; The working fluid arrives at the compressor as a cool, low-pressure gas. The compressor is powered by electricity to squeeze
More informationSlim Contour Unit Cooler
Slim Contour Unit Cooler with Modular Cassette Design ULA Models Questions & Answers Table of Contents What is the Slim Contour unit cooler?... 2 Why was this product developed?... 2 What are the key benefits
More informationSYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING
SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING INDEX 1. Introduction 3 2. Objectives 3 3. Employment Opportunity 4 4. Course Structure 4 5. Entry Qualification 4 6. List
More informationCommercial Packaged Rooftop Units 3- to 50-Ton LC/LG Models. Up to 17.0 SEER, Up to 12.8 EER
Commercial Packaged Rooftop Units 3- to 50-Ton LC/LG Models Up to 17.0 SEER, Up to 12.8 EER SAVING ENERGY WITH INTELLIGENCE Designed to intelligently achieve the lowest total cost of ownership Energence
More informationAIR CONDITIONING TECHNOLOGY
AIR CONDITIONING TECHNOLOGY PART 9 Water Cooled Condensers & Cooling Towers IN LAST month s article we looked at how Air Cooled Condensers are used to transfer the total heat of rejection from the air
More informationHow Ground/Water Source Heat Pumps Work
How Ground/Water Source s Work Steve Kavanaugh, Professor Emeritus of Mechanical Engineering, University of Alabama Ground Source s (a.k.a. Geothermal s) are becoming more common as the costs of energy
More informationAir-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"
Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A" Takahiro OUE *1, Kazuto OKADA *1 *1 Refrigeration System & Energy Dept., Compressor Div., Machinery Business Kobe Steel has developed an air-sourced
More information01-3 6820-11 6820-11 AIR CONDITIONER GENERAL 1. SPECIFICATIONS AIR CONDITIONER REXTON 2010.01
682011 013 GENERAL 1. SPECIFICATIONS 682011 014 682011 2. REPAIR INSTRUCTIONS 1) Precautions for Working with R134a R12 refrigerant and R134a refrigerant are not compatible. These refrigerants must never
More informationSTATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK COURSE OUTLINE. ACHP 104 Refrigeration & Air Conditioning Service II
STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK COURSE OUTLINE ACHP 104 Refrigeration & Air Conditioning Service II Prepared By: Stan Skowronek CANINO SCHOOL OF ENGINEERING TECHNOLOGY
More informationPreventive Maintenance. State Energy Assessment Workshop By: DTE Energy Partnership & Services
Preventive Maintenance State Energy Assessment Workshop By: DTE Energy Partnership & Services Do you know? World wide research has shown that one of the reasons causing 80% of the accidents is deficient
More informationHow air conditioning works
1 How air conditioning works The essential ingredients in an air conditioning system are a fan to blow air around, a cold surface to cool and dehumidify the air, a warm surface and a source of water vapour.
More informationSERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
More informationwww.howden.com AustCold INDUSTRIAL REFRIGERATION AND GAS COMPRESSION PLANT
www.howden.com AustCold INDUSTRIAL REFRIGERATION AND GAS COMPRESSION PLANT 2 1 THE DRIVING FORCE BEHIND OUR TECHNOLOGY FOR OVER THREE DECADES, HAVE BEEN A MAJOR SUPPLIER OF LARGE INDUSTRIAL SKID-MOUNTED
More informationSECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
More informationWhy Daikin? 2015 Houston, Texas USA www.daikincomfort.com
Why Daikin? Daikin: The Premium Brand industry leader Daikin is recognized as the world s number one leader in the manufacture of HVAC equipment and refrigerants. For over 90 years, Daikin has grown consistently
More informationNordic Heat Pump Product Guide
Nordic Heat Pump Product Guide About Maritime Geothermal Maritime Geothermal is a privately owned, Canadian based manufacturer of geothermal heat pumps. We began manufacturing the Nordic line of heat pumps
More informationDew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2
Instruction Manual Dew Point Tester The CVS Dew Point Tester is a chilled mirror apparatus, which operates by attaining the conditions necessary by the definition of dew point. When a gas is cooled out
More informationThe HVAC Process: Changing the Properties of Air
The HVAC Process: Changing the Properties of Air Alexander Delli Paoli, Jr. ABSTRACT This discussion addresses the physical properties of air and water vapor mixtures. The components of the heating, ventilation,
More informationThe information provided below is intended for emergency recovery and response, not general treatment recommendations.
NATIONAL ARCHIVES AND RECORDS ADMINISTRATION PRESERVATION PROGRAMS The information provided below is intended for emergency recovery and response, not general treatment recommendations GENERAL INFORMATION
More informationComparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal
Technical Bulletin By Bruce I. Nelson, P.E., President, Colmac Coil Manufacturing, Inc. Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal SUMMARY Refrigeration air coolers (evaporators)
More informationFan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain Ship. Wt. Lbs.
COMPACT UNIT FOR CEILING OR WALL MOUNT Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain. MJ-40 400 600 7 13 5/8 8 125 5 1/4" 0.65 0.35
More informationHOW TO SELECT A LOW VOLUME (L.V ) BOILER
HOW TO SELECT A LOW VOLUME (L.V ) BOILER FREQUENTLY ASKED QUESTIONS OR COMMENTS ON BOILERS Dear Potential Customer: Low Volume Operator Exempt boilers have been marketed in Ontario to eliminate the requirement
More informationNew Trends in the Field of Automobile Air Conditioning
New Trends in the Field of Automobile Air Conditioning E. Janotkova and M. Pavelek Department of Thermomechanics and Environmental Engineering Brno University of Technology, 61669 Brno, Czech Republic
More informationUSER S GUIDE For all Packaged Systems (Air Conditioners and Heat Pumps)
USER S GUIDE For all Packaged Systems (Air Conditioners and Heat Pumps) WA & WL - Series Air Conditioners WH & SH - Series Air Source Heat Pumps IH - Series Air Source Heat Pumps DATE: 02-21-12 QA - Series
More informationLesson 36 Selection Of Air Conditioning Systems
Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section
More informationREFRIGERATED COMPRESSED AIR DRYERS
INNOVATIVE COMPRESSED AIR SOLUTIONS COMPRESSED AIR SOLUTIONS REFRIGERATED COMPRESSED AIR DRYERS WITH TRUE-CYCLING OPERATION 75 2,400 scfm Capacity Models STAINLESS STEEL HEAT EXCHANGERS www.zeks.com Compressed
More informationSolar Desiccant Air Conditioner
Department of Mechanical Engineering ME 490 B Solar Desiccant Air Conditioner Luis Hernandez Joel Heywood Abhishek Kumar Yzzer Roman Advisor: Dr. Fletcher Miller Table of Contents Page 1. Abstract. 3 2.
More informationCondensing Economizers Workshop Enbridge Gas, Toronto. MENEX Boiler Plant Heat Recovery Technologies. Prepared by: Jozo Martinovic, M A Sc, P Eng
Condensing Economizers Workshop Enbridge Gas, Toronto MENEX Boiler Plant Heat Recovery Technologies Prepared by: Jozo Martinovic, M A Sc, P Eng MENEX Innovative Solutions May 15, 2008 MENEX INC. 683 Louis
More information