1 Pump Motors
2 Why Baldor? Industry s shortest lead times/flexible manufacturing. Baldor has the industry s shortest lead times on custom motors just ten working days. Our unique LEAN FLEX FLOW manufacturing process lets us produce any order in any quantity, quickly and efficiently. For nearly 100 years, Baldor has strived to provide customers with the best value and reliability in industrial electric motors. That dedication shows in customer preference for Baldor Reliance motors. To be considered as the most preferred... Baldor offers the industry s broadest line of stock products. Save valuable time with just one call to Baldor. We offer more than 10,000 stock motors, drives and gearboxes. Energy-efficiency leader. We began lowering the energy consumption of our motors in the 1920s, long before others were even talking about it. Today, our expansive line of Super-E premium-efficient motors ranges from 1 through 15,000 Hp. Baldor s Super-E line offers customers the highest overall efficiency levels in the industry. Baldor products are available at more locations than any other brand. Our 36 district offices across North America and hundreds of ABB offices around the world, offer immediate availability of Baldor products to thousands of customers. Continuous innovation to improve reliability. Baldor leads the motor industry in applying new technologies to improve motor reliability. Recent improvements to the line of Severe Duty motors are further proof that Baldor is the leader in motors for process industry applications. These improvements are explained in detail in the following pages. Industry s best information. Only Baldor offers customers so many choices for product information with a wide variety of catalogs and product brochures, the Baldor Web site at or you may talk to a Baldor customer service person at one of our sales offices. Table of Contents Page Why Baldor? b Baldor Pump Motors 1 Energy Efficiency 2 Pump Motor Construction 3 TEFC/ODP - Pump Motor Capabilities 4 Close Coupled Pump Motor Design Features 5 Close Coupled Single Phase TEFC & ODP 6 Close Coupled Three Phase TEFC 7 Close Coupled Three Phase ODP 10 Close Coupled Pump Motors with AEGIS Grounding Ring 13 Close Coupled Pump Washdown 14 Stainless Steel Encapsulated Motors 14 Jet Pump Motor Design Features 15 Jet Pump Motors Single Phase 16 Jet Pump Motors Three Phase 18 Jet Pump Motors Explosion-Proof 19 Close Coupled Pump Explosion-Proof Motors 20 Square Flange Pump Motor 21 SAE Hydraulic Pump Motors 21 Vertical P-Base Motors 22 Vertical P-Base TEFC 23 Vertical P-Base ODP 25 Submersible Motors 26 Immersible Motors 29 Dimension Diagrams 32 Connection Diagrams 54
3 Baldor Pump Motors Baldor Reliance is the leading supplier of Pump Motors to meet industrial and commercial applications. From industrial waste water to commercial pool pump motors Baldor Reliance pump motors provide exceptional value by increasing reliability and reducing maintenance costs. Baldor also leads the way in helping customers save money in pump applications by using energy efficient designs. Baldor Reliance Super E Pump Motors provide Premium efficiency and are designed as standard to be invertor ready with wide variable torque speed ranges. Over 525 Stock Motor Ratings Today s line of Baldor Pump motors offers customers some from the highest levels of efficiencies, in ratings from fractional to 15,000 horsepower. Baldor has ratings available immediately from stock, with non-stock motors with the industry s shortest load times. The Right Pump Motor for your Application Whether it s a premium efficient pump motor for industrial waste water, sewage treatment facility or processing applications moving fluids in harsh conditions Baldor offers customers a variety of choices. Baldor Reliance also offers pump motors designed for hazardous area locations common in the petroleum refining, chemical, processing and water treatment. Baldor Reliance Close-Coupled & Jet Pump motors are available in a wide variety of construction enclosures from industrial steel band open designs to harsh applications requiring totally enclosed cast iron design. Various mounting provisions from JM, JP and Westcoast are available as stock and custom. Motor construction can be tailored for specific applications and industries such as food processing, washdown applications or explosion proof enclosures for pumps in hazardous areas. Baldor Reliance solid shaft Vertical P-Base are the perfect power mates for centrifugal pumps, sump pumps, turbine pumps, in-line process pumps, fans, aerators, mixers, autoclaves, cooling towers and similar applications in industrial environments. These motors are available in a variety of enclosures and thrust values to suit your application. All frames have cast iron construction and premium features to protect motor components from chemicals, corrosion and abrasives, extending motor life and improving performance. Baldor Reliance LP and VP motors are designed to meet the American Petroleum Institute Standard 610. Whether your application is under water or has the potential to be underwater Baldor Reliance has a motor for you. Baldor offers submersible motors serving both municipal and industrial waste water markets for both wet and dry pit applications. Submersible motors are suitable for hazardous and nonhazardous applications on both sine wave and invertor power. Baldor Reliance custom immersible motors are designed for use in nonhazardous dry pit applications where the possibility of flooding exists. Baldor Reliance Immersible motors are the right choice for an application where the features of a submersible A Baldor Super-E motor and Inverter Control provide premium energy efficiency and improved process control to a municipal water treatment facility. motor would not be fully utilized. Immersible motors save on installation cost by eliminating support structure and shaft extensions typically required to mount a pump motor above the high water level of the pit. They also reduce maintenance costs for replacing motors that cannot operate under water. Leadership in Premium Efficiency Called a key breakthrough by the Consortium for Energy Efficiency, the CEE in 1998 recognized Baldor s Super-E as the first premium efficient motor line to meet their stringent efficiency criteria, citing For the first time, one manufacturer will carry all qualifying products. Minimum Efficiency Performance Standards (MEPS) for electric motors are becoming commonplace throughout the world. The first of these was the Energy Policy Act of 1992 (EPAct) that mandated efficiency levels for Hp general purpose motors for sale in the U.S. after October The Energy Independence and Security Act of 2007 (EISA) builds upon EPAct and raises the efficiency level for these motors to Premium efficiency and adds other configuration and Hp ratings for MEPS compliance. Baldor Reliance Super-E motors manufactured today meet or exceed EISA requirements. As countries and regions across the world establish minimum efficiency levels for motors, more companies are turning to the Baldor Reliance Super-E. This includes plant and processing applications, as well as OEM products for shipment overseas. Super-E motors meet or exceed the efficiency levels defined by The Energy Independence & Security Act of 2007 (EISA) in the U.S., NRC in Canada, and IEC IE3 level in Europe. Super-E motors meet or exceed Premium efficiencies. A wide selection of premium efficient motors, available from stock, manufactured and sold by a company committed to building better products for industries worldwide. No wonder, since the 1920s, Baldor Reliance is recognized as the leader in energy efficient industrial motors and drives. 1
4 Making Energy Efficiency Work For You Why is Energy Efficiency Important? Electric motor-driven systems used in industrial processes consume 63% of all electricity used in U.S. industrial sector according to a U.S. Department of Energy report published in A 2002 report shows that companies that practiced DOE best practices actually averaged 33 percent savings if they were to apply motor and motor system efficiency upgrades, including the use of adjustable speed drives. The potential positive impacts on companies bottom lines and the environment are significant. Purchase Price is Only a Small Piece of the Pie The pie chart to the right shows the typical life cycle cost of a 100 Hp motor operating in continuous duty over a 20-year life. As you can see, the original purchase price is almost insignificant compared to what it will cost to power the motor during its useful life. How Baldor Super-E Efficiencies Compare to Industry Standards Baldor s line of Super-E motors offers customers the highest level of overall efficiencies available from any motor manufacturer, meeting or exceeding Premium efficiency. BE$T Baldor Energy Savings Tool Makes Calculating Payback Easy In order to make payback calculations easier for customers, Baldor developed BE$T, Baldor Energy Savings Tool. The software helps calculate energy cost and energy savings for motors, as well as payback time frames. A popular feature of BE$T is that it allows users to make head-to-head comparisons of up to three motors, giving customers the information to make an informed decision through comparative analysis. BE$T, Baldor Energy Savings Tool is available as a download through Baldor s award-winning Web site ( as well as a stand-alone CD-ROM, available from your Baldor District Office. Electric Motor Efficiency Ratings $1500 What is Higher Efficiency Worth?
5 Pump Motor Construction Our pump line of motors includes single or three phase jet pump motors, square flange motors, close-coupled pump motors, and P-Base vertical solid shaft pump motors. The motors are stocked in totally enclosed fan cooled, open drip proof, and many explosion proof ratings. Applications for these run the gamut from swimming pool pumps to medium and high thrust in-line pumps used in water treatment plants. Horse powers range in size from 1/3 through 75 HP. The chart below lists standard features ( S ) of Baldor s single and three phase pump motors. ranges indicate where certain features are standard in stock products. Optional ( O ) indicates additional features available on custom motors, or through Baldor s Mod-Express. Electrical Features Single and Three Phase Pump Motor Family Jet Pump Close Coupled JM/JP Vertical P Base Solid Shaft Class F insulation with B rise O O S 1.15 Service factor or greater S S S 200 C Inverter spike resistant insulation system S S S Phase insulation S S Corona inception testing - meets Part S S Varnish dip & bake with 100% solids S S S Ground Terminal inside main conduit box S S S Mechanical Features sizes UL Component Recognized and CSA Approved S S S Steel Band S S ODP S TEFC Cast iron frame S TEFC S Conduit box rotatable 90 increments S S Die cast aluminum conduit box S S S - ODP Cast iron conduit box O S TEFC O - ODP Threaded inlet hole in conduit box O O S Neoprene conduit box lid gasket & lead separator gasket O S Seal endplate to frame joints O O S Hardware - zinc plated S S S Motor unfiltered vibration at rated voltage and frequency <0.15 in/sec peak velocity S S Motor unfiltered vibration at rated voltage and frequency <0.08 in/sec peak velocity O O S Exxon Polyrex EM polyurea grease S S S Grease inlet with grease fitting O S S Grease inlet with screw-in plug O O O Grease outlet with screw-in plug O O Grease outlet with automatic relief fitting S S Non-metallic external cooling fan S S S Castings coated with 2-part epoxy primer and epoxy finish coat O O S ASTM B hour salt spray test compliance O S Laser etched aluminum nameplate with data S S Embossed Stainless steel nameplate with data O O S Stainless steel nameplate with bearing and grease data S UL 1081 Compliant via Mod Express M30A O Limited Warranty 1 year Std Eff 18 months Premium Eff 3 year 3 year Note: Contact your Baldor District Office for certified data, dimensions and features of a specific motor. 3
6 TEFC/ODP - Pump Motor Capabilities Single and Three Phase Single Phase - Typical Size / Speed - RPM TEFC Hp /3 56C/J 56C/J 56C/J 56C/J 1/2 56C/J 56C/J 56C/J 56C/J 3/4 56C/J 56C/J 56C/J 56C/J 1 56C/J 56C/J 56C/J 56C/J C/J 56C/J 56C/J 56C/J 2 56C/J 56C/J 56C/J 56C/J 3 56C/J or 182JM/JP 56C/J or 184JM/JP 56C/J or 182JM/JP 56C/J or 184JM/JP 5 184JM/JP 184JM/JP or 213JM/JP 184JM/JP 184JM/JP or 213JM/JP JM/JP 215JM/JP 213JM/JP 215JM/JP JM/JP 215JM/JP 215JM/JP 215JM/JP Three Phase - Typical Size / Speed - RPM TEFC Hp /3 56C/J 56C/J 56C/J 56C/J 1/2 56C/J 56C/J 56C/J 56C/J 3/4 56C/J 56C/J 56C/J 56C/J 1 56C/J or 143JM/JP 56C/J or 143JM/JP 56C/J or 143JM/JP 56C/J or 143JM/JP C/J or 143JM/JP 56C/J or 145JM/JP 56C/J or 143JM/JP 56C/J or 145JM/JP 2 56C/J or 145JM/JP 56C/J or 145JM/JP 56C/J or 145JM/JP 56C/J or 145JM/JP 3 56C/J, 145JM/JP or 182JM/JP/HP/LP ODP ODP 56C/J or 182JM/JP/HP/LP 56C/J or 145JM/JP 56C/J or 182JM/JP/HP/LP 5 184JM/JP/HP/LP 184JM/JP/HP/LP 182JM/JP/HP/LP 184JM/JP/HP/LP JM/JP or 213JM/JP/HP/LP/VP 213JM/JP/HP/LP/VP 184JM/JP/HP/LP 213JM/JP/HP/LP/VP JM/JP/HP/LP/VP 215JM/JP/HP/LP/VP 213JM/JP/HP/LP/VP 215JM/JP/HP/LP/VP JM/JP or 254JM/JP/HP/LP/VP 254JM/JP/HP/LP/VP 215JM/JP/HP/LP/VP 254JM/JP/HP/LP/VP JM/JP/HP/LP/VP 256JM/JP/HP/LP/VP 254JM/JP/HP/LP/VP 256JM/JP/HP/LP/VP JM/JP/HP/LP/VP 284JM/JP/HP/LP/VP 256JM/JP/HP/LP/VP 284JM/JP/HP/LP/VP JM/JP/HP/LP/VP 286JM/JP/HP/LP/VP 284JM/JP/HP/LP/VP 286JM/JP/HP/LP/VP JM/JP/HP/LP/VP 324JM/JP/HP/LP/VP 286JM/JP/HP/LP/VP 324JM/JP/HP/LP/VP JM/JP/HP/LP/VP 326JM/JP/HP/LP/VP 324JM/JP/HP/LP/VP 326JM/JP/HP/LP/VP JP/HP/LP/VP 364JP/HP/LP/VP 326JM/JP/HP/LP/VP 364JP/HP JP/HP/LP/VP 365JP/HP/LP/VP 364JP/HP 365JP/HP HP/LP/VP 405HP/LP/VP 365JP/HP 404HP HP/LP/VP 444HP/LP/VP 404HP 405HP HP/LP/VP 445HP/LP/VP 405HP 444HP HP/LP/VP 447HP/LP/VP 444HP 445HP HP/LP/VP 449HP/LP/VP 445HP 447HP HP/LP/VP 449HP/LP/VP 447HP 449HP HP/LP/VP 449HP/LP/VP 449HP 449HP HP/LP/VP 449HP/LP/VP 449HP 449HP HP 449HP NOTE: West Coast pump mountings are available in 143 thru 286 frames. Motors listed with catalog numbers in this brochure are available from stock. Contact Baldor for lead times on non-stock motors. Performance data is subject to change. Drawings shown are for reference only. Please contact Baldor for current performance data or a detailed drawing on the specific motor you require. Data and drawings may be available from our website at 4
7 Baldor Reliance Close Coupled Pump Motors Baldor Reliance Pump Motors are available in Super-E, Premium efficient designs. The same engineering and manufacturing knowledge and experience that go into every horizontal Baldor Reliance Super-E motor also go into every Baldor Reliance Close Coupled Pump motor produced. Fan cover designed to provide maximum cooling and quiet operation Bi-directional cooling fan designed for low friction and windage losses End turn lacing on both ends of the winding prevent electrical failures High-pressure die cast aluminum rotor coated to reduce corrosion Locked bearing construction reduces shaft endplay Regreaseable antifriction ball bearings for long motor life Over-sized conduit box exceeding NEC standards, make connections easier Electrical grounding terminal inside conduit box Dual mounting foot holes for easy mounting in replacement applications Inverter spike resistant insulation system meets the requirements for MG 1 Part for VFD use and is considered inverter ready Mobil Polyrex EM grease for greater bearing protection and improved lubrication life Drive-end shaft extension meets requirements for Close-Coupled pump applications. All Baldor Reliance Super-E motors meet or exceed Premium efficiency requirements per MG 1 table
8 Close Coupled Pump Motors Single Phase TEFC & ODP Baldor close coupled pump motors are designed to meet the mounting requirements of JM, JP and West Coast Fit residential and industrial pump applications. Construction features include a heavy gauge steel frame, cast aluminum end plates with steel bearing seat inserts for mechanical reliability. These motors have a corrosion resistant finish and are suitable to mount in any position. These single phase designs have Class B insulation and a 1.15 service factor for long life. Single Phase, 115/ , 115/230 and 230 Volt, 3-10 HP Hp kw RPM Catalog Number High V Locked Rotor Torque Lb. Ft. Efficiency % Power Factor % Bearings 1/2 3/4 1/2 3/4 Totally Enclosed Fan Cooled, Mechanical Seal, Type JM JM JML3606T B CD0001 1, JM JML3608T C CD0017A02 2,20 Open Drip Proof, Mechanical Seal, Type JM JM JML1406T A CD JM JML1408T B CD0016A JM JML1409T C CD0017A02 1, JM JML1508T C CD0017A JM JML1509T C CD0017A JM JML1510T C CD0017A JM JML1511T C CD0017A01 1, JM JML1512T C CD0086 1,30 Open Drip Proof, Packed Pump, Type JP JP JPL1406T B CD JP JPL1408T B CD0016A JP JPL1409T C CD0017A02 1, JP JPL1508T C CD0017A JP JPL1509T C CD0017A JP JPL1510T C CD0017A JP JPL1511T C CD0017A01 1, JP JPL1512T C CD0086 1,30 Open Drip Proof, West Coast Fit, Type TCZ TCZ WCL1406T B 19.7 CD TCZ WCL1408T B 19.7 CD0016A TCZ WCL1409T C 19.7 CD0017A01 1, TCZ WCL1508T C CD0017A TCZ WCL1509T C CD0017A TCZ WCL1511T C CD0017A01 1,30 NOTE: Volt Code: Volt Code: A = 115/ V, 60Hz; B = 115/230V, 60Hz; C = 230V, 60Hz 1 Class F Insulated Motor with 1.15 Service Factor or higher that operates within Class B temperature limits at rated horsepower Service Factor 20 Class F Insulation 30 Usable at 208 Volt See pages and 58 for connection diagrams. See pages 38 and 39 for dimensions. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. DE ODE Volt Code C Dim. Conn. Diag. No. Notes 6
9 Close Coupled Pump Motors Three Phase TEFC These motors are designed and manufactured to meet the needs of circulating and transferring fluid applications. The motor flange and shaft are designed to support the pump unit. Close coupled Pump motors include Over-sized ball bearings with locked drive end construction to minimize endplay. These Super-E motors (EJPM & EJMM) meet Premium Efficiency requirements, have a 1.15 service factor and Class F insulation. TEFC - Totally Enclosed Fan Cooled, 230/460 & 575 Volts, Three Phase, 1-50 Hp Hp kw RPM Catalog Number High V Locked Rotor Torque Lb. Ft. Efficiency % Power Factor % Bearings 1/2 3/4 1/2 3/4 230/460 Volt, Foot Mounted JM EJMM3546T E CD JM JMM3546T E CD / JM EJMM3550T E CD / JM JMM3550T E CD / JM EJMM3554T E CD / JM JMM3554T E CD / JP JPM3554T E CD JM EJMM3555T E CD JM JMM3555T E CD JP JPM3555T E CD JM EJMM3558T E CD JM JMM3558T E CD JP JPM3558T E CD JM EJMM3559T E CD JM JMM3559T E CD JP JPM3559T E CD JM EJMM3610T E CD JM JMM3610T E CD JP JPM3610T E CD JM EJMM3611T E CD JM JMM3611T E CD0005 1, JP JPM3611T E CD0005 1, JM EJMM3613T E CD JM JMM3613T E CD JP JPM3613T E CD JM EJMM3615T E CD JM JMM3615T E CD0005 1, JP JPM3615T E CD0005 1,35 7 1/ JM EJMM3616T E CD / JM JMM3616T E CD0005 1, / JP JPM3616T E CD0005 1, / JM EJMM3709T F CD0005 1, / JM JMM3709T E CD0005 1,35 7 1/ JP JPM3709T E CD / TCZ WCM3709T E CD0005 1,35 7 1/ JM EJMM3710T E CD0005 1, 30, / JM JMM3710T E CD0005 1,35 7 1/ JP JPM3710T E CD0005 1,35 7 1/ TCZ WCM3710T E CD0005 1, JM EJMM3711T E CD JM JMM3711T E CD JP JPM3711T E CD TCZ WCM3711T E CD NOTE: Volt Code: E = /460V, 60Hz; E1 = 230/460V, 60Hz, usable at 208V; F = 230/460V, 60Hz; H = 575V, 60 Hz Shaded ratings are cast iron frames. 1 Class F Insulated Motor with 1.15 Service Factor or higher that operates within Class B temperature limits at rated horsepower 35 Design A See page 56 for connection diagrams. See pages 32 and 33 for dimensions. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. DE Volt Code C Dim. Conn. Diag. No. Notes 7 ODE
10 8 TEFC - Totally Enclosed Fan Cooled, 230/460 & 575 Volts, Three Phase, 1-50 Hp Hp kw RPM High V Efficiency % Power Factor % Bearings Conn. Catalog Volt C Torque Number Locked Diag. Code Dim. Lb. Ft. 1/2 3/4 Rotor 1/2 3/4 DE ODE No. Notes JM EJMM3714T E CD0005 1, JP EJPM3714T E CD0005 1, JM JMM3714T E CD0005 1, JP JPM3714T E CD0005 1, TCZ WCM3714T E CD0005 1, JM JMM3713T E CD , JP JPM3713T E CD , TCZ WCM3713T E CD , JM EJMM2394T E CD0180 1, JP EJPM2394T E CD JM JMM2394T E CD0005 1, JP JPM2394T E CD0005 1, JM EJMM2333T E CD0005 1, 30, JP EJPM2333T E CD0005 1, JM JMM2333T E CD0005 1, JP JPM2333T E CD0005 1, JM EJMM4106T E CD0005 1, JP EJPM4106T E CD JM JMM4106T E CD0005 1, JP JPM4106T E CD0005 1, JM EJMM2334T E CD0005 1, JP EJPM2334T E CD0005 1, JM JMM2334T E CD0005 1, JP JPM2334T E CD0005 1, JM EJMM4107T E CD JP EJPM4107T E CD JM JMM4107T E CD0180 1,30, JP JPM4107T E CD0180 1,30, JM EJMM4103T E CD0005 1,30, JP EJPM4103T E CD0005 1,30, JM JMM4103T E CD0005 1, JP JPM4103T E CD0005 1, JM EJMM4108T E CD JP EJPM4108T E CD JM JMM4108T E CD0180 1, 30, JP JPM4108T E CD0180 1, JM EJMM4104T E CD0005 1, JP EJPM4104T E CD0005 1, JM JMM4104T E CD0005 1, JP JPM4104T E CD0005 1, JM EJMM4109T E CD JP EJPM4109T E CD JM JMM4109T E CD0180 1, JP JPM4109T E CD0180 1, JM EJMM4110T E CD0180 1, JP EJPM4110T E CD0180 1, JM JMM4110T E CD0180 1, JP JPM4110T E CD0180 1, JM EJMM4114T E CD0180 1, JP EJPM4114T E CD0180 1, 30, JM JMM4114T E CD0180 1, JP JPM4114T E CD0180 1, JM EJMM4115T E CD0180 1, 30, JP EJPM4115T E CD0180 1, 30, JM JMM4115T E CD0180 1, JP JPM4115T E CD0180 1, 30 NOTE: Volt Code: E = /460V, 60Hz; E1 = 230/460V, 60Hz, usable at 208V; F = 230/460V, 60Hz; H = 575V, 60 Hz 1 Class F Insulated Motor with 1.15 Service Factor or higher that operates within Class B temperature limits at rated horsepower 20 Class F Insulation 30 Usable at 208 Volts 35 Design A See pages 56 and 57 for connection diagrams. See pages 32 and 33 for dimensions. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. Shaded ratings are cast iron frames.
11 TEFC - Totally Enclosed Fan Cooled, 230/460 & 575 Volts, Three Phase, 1-50 Hp Hp kw RPM Catalog Number High V Locked Rotor Torque Lb. Ft. Efficiency % Power Factor % Bearings 1/2 3/4 575 Volt, Foot Mounted 1/2 3/ JM JMM3546T H CD / JM JMM3550T H CD / JM JMM3554T H CD JM JMM3555T H CD JM JMM3558T H CD JM JMM3559T H CD JM JMM3610T H CD JM JMM3611T H CD0006 1, JM JMM3613T H CD JM JMM3615T H CD0006 1, / JM JMM3616T H CD / JM JMM3710T H CD0006 1, JM JMM3711T H CD JM JMM3714T H CD0006 1, JM JMM3713T H CD0006 1, JM JMM2394T H CD0006 1, JM JMM2333T H CD0006 1, /460 Volt, Footless JM VEJMM3546T E CD JM VJMM3546T E CD / JM VEJMM3554T E CD / JM VJMM3554T E CD JM VEJMM3558T E CD JM VJMM3558T E CD JM VEJMM3611T E CD JM VJMM3611T E CD JM VEJMM3615T E 19.7 CD JM VJMM3615T E CD0005 1,35 7 1/ JM VEJMM3710T E CD0005 1, 30, / JM VJMM3710T E CD0005 1, JM VEJMM3714T E 22.4 CD0005 1, JM VJMM3714T E CD0005 1, JM VJMM2333T E CD0005 1, JM VJMM2334T E CD0180 1, Volt, Footless JM VJMM3546T H CD / JM VJMM3554T H CD JM VJMM3558T H CD JM VJMM3611T H 18.2 CD0006 1, JM VJMM3615T H CD / JM VJMM3710T H CD0006 1, JM VJMM3714T H CD0006 1, JM VJMM2333T H CD0006 1, JM VJMM2334T H CD NOTE: Volt Code: E = /460V, 60Hz; E1 = 230/460V, 60Hz, usable at 208V; F = 230/460V, 60Hz; H = 575V, 60 Hz 1 Class F Insulated Motor with 1.15 Service Factor or higher that operates within Class B temperature limits at rated horsepower 30 Usable at 208 Volts 35 Design A See pages 56 and 57 for connection diagrams. See page 32 for dimensions. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. DE ODE Volt Code C Dim. Conn. Diag. No. Notes Shaded ratings are cast iron frames. 9
12 Close Coupled Pump Motors Three Phase - ODP These motors are designed and manufactured to meet the needs of circulating and transferring fluid applications. The motor flange and shaft are designed to support the pump unit. Close coupled Pump motors include Over-sized ball bearings with locked drive end construction to minimize endplay. Open Drip Proof frame designs include rodent screens on both ends. Super-E motors (EJMM, EJPM & VEJM) meet Premium Efficiency requirements, have a 1.15 service factor and Class F insulation. 10 ODP - Open Drip Proof, 230/460 & 575 Volts, Three Phase, 1-75 Hp Hp kw RPM High V Efficiency % Power Factor % Bearings Catalog Volt C Conn. Torque Number Locked Code Dim. Diag. No. Rotor Lb. Ft. 1/2 3/4 1/2 3/4 DE ODE Notes 230/460 Volt, C-Face Footmounted JM EJMM3116T E CD JM JMM3116T E CD JP JPM3116T E CD / JM JMM3120T E CD / JM EJMM3154T F CD0005 1, / JM JMM3154T E CD / JP JPM3154T E CD JM EJMM3155T E CD JM JMM3155T E CD JM EJMM3157T F CD0005 1, JM JMM3157T E CD JP JPM3157T E CD JM EJMM3158T E CD0005 1, JM JMM3158T E CD JP JPM3158T E CD JM EJMM3211T E CD0005 1, JM JMM3211T E CD JP JPM3211T E CD JM EJMM3212T E CD0005 1, JM JMM3212T E CD JP JPM3212T E CD TCZ WCM3212T E CD JM EJMM3218T E 18 CD JM JMM3218T E 16.5 CD0005 1, JP JPM3218T E CD0005 1, JM JMM3309T E CD / JM EJMM3219T E 16.5 CD0005 1, / JM JMM3219T E 16.5 CD / JP JPM3219T E CD / TCZ WCM3219T E CD / JM EJMM3311T E CD0005 1, 30, / JM JMM3311T E CD0005 1, / JP JPM3311T E CD0005 1, / JM JMM2506T E CD0005 1, JM EJMM3312T E CD JP EJPM3312T E CD JM JMM3312T E CD JP JPM3312T E CD TCZ WCM3312T E CD JM EJMM3313T E CD0005 1, JP EJPM3313T E CD JM JMM3313T E CD0005 1, JP JPM3313T E 22.1 CD0005 1, JM JMM2511T E CD JM EJMM3314T E CD JP EJPM3314T E CD NOTE: Volt Code: E = /460V, 60Hz; E1 = 230/460V, 60Hz, usable at 208V; F = 230/460V, 60Hz; H = 575V, 60 Hz 1 Class F Insulated Motor with 1.15 Service Factor or higher that operates within Class B temperature limits at rated horsepower 30 Usable at 208 Volts 35 Design A See pages 56 and 57 for connection diagrams. See pages 35 and 36 for dimensions. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data.
13 ODP - Open Drip Proof, 230/460 & 575 Volts, Three Phase, 1-75 Hp Hp kw RPM High V Efficiency % Power Factor % Bearings Catalog Volt C Conn. Torque Number Locked Code Dim. Diag. No. Rotor Lb. Ft. 1/2 3/4 1/2 3/4 DE ODE Notes JM JMM3314T E CD JP JPM3314T E CD TCZ WCM3314T E CD JM EJMM2513T E CD0180 1, JP EJPM2513T E CD JM JMM2513T E CD0005 1, JP JPM2513T E CD0005 1, JM JMM2524T E CD JM EJMM2514T E CD0180 1, JP EJPM2514T E CD0180 1, JM JMM2514T E CD JP JPM2514T E CD JM EJMM2515T E CD0180 1, JP EJPM2515T E CD0180 1, JM JMM2515T E CD0005 1, JP JPM2515T E CD0005 1, JM EJMM2516T E CD0180 1, JP EJPM2516T E CD0180 1, JM JMM2516T E CD JP JPM2516T E CD JM EJMM2531T F CD JP EJPM2531T E CD0180 1, JM JMM2531T E CD JP JPM2531T E CD JM EJMM2534T F CD0005 1, JP EJPM2534T F CD0005 1, JM JMM2534T E CD JP JPM2534T E CD JM EJMM2535T F CD0005 1, JP EJPM2535T E CD0005 1, JM JMM2535T E CD JP JPM2535T E CD JM EJMM2538T F CD0180 1, JP EJPM2538T F CD0180 1, JM JMM2538T E CD JP JPM2538T E CD JM EJMM2539T F CD0005 1,30, JP EJPM2539T E CD0180 1, JM JMM2539T E CD0005 1, JP JPM2539T E CD0005 1, JM EJMM2542T E CD JP EJPM2542T F CD JM JMM2542T E CD JP JPM2542T E CD JM EJMM2543T F CD0180 1, JP EJPM2543T E CD0180 1, JM JMM2543T E CD JP JPM2543T E CD JM JMM2546T E CD JP JPM2547T E CD JP JPM2551T E CD NOTE: Volt Code: E = /460V, 60Hz; E1 = 230/460V, 60Hz, usable at 208V; F = 230/460V, 60Hz; H = 575V, 60 Hz 1 Class F Insulated Motor with 1.15 Service Factor or higher that operates within Class B temperature limits at rated horsepower 30 Usable at 208 Volts 35 Design A See pages 56 and 57 for connection diagrams. See pages 35 and 36 for dimensions. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. 11
14 ODP - Open Drip Proof, 230/460 & 575 Volts, Three Phase, 1-75 Hp Hp kw RPM High V Efficiency % Power Factor % Bearings Conn. Catalog Volt C Torque Number Locked Diag. Code Dim. Lb. Ft. 1/2 3/4 Rotor 1/2 3/4 DE ODE No. Notes 260/460 Volt, C-Face Footless JM VEJMM3116T E CD JM VJMM3116T E CD / JM VEJMM3154T F CD / JM VJMM3154T E CD JM VEJMM3157T F CD0005 1, JM VJMM3157T E CD JM VJMM3158T E CD JM VEJMM3211T E CD0005 1, JM VJMM3211T E CD JM VJMM3212T E CD JM VEJMM3218T E CD JM VJMM3218T E CD0005 1, / JM VJMM3219T E CD / JM VEJMM3311T E CD0005 1, 30, / JM VJMM3311T E CD0005 1, JM VJMM3312T E CD JM VEJMM3313T E CD0005 1, JM VJMM3313T E CD JM VJMM3314T E CD Volt, Foot Mounted JM JMM3158T H CD JM JMM3211T H CD JM JMM3212T H CD JM JMM3218T H 16.5 CD0006 1, / JM JMM3219T H 16.5 CD / JM JMM3311T H CD0006 1, JM JMM3312T H CD JM JMM3313T H CD0006 1, JM JMM3314T H CD NOTE: Volt Code: E = /460V, 60Hz; E1 = 230/460V, 60Hz, usable at 208V; F = 230/460V, 60Hz; H = 575V, 60 Hz 1 Class F Insulated Motor with 1.15 Service Factor or higher that operates within Class B temperature limits at rated horsepower 30 Usable at 208 Volts 35 Design A See page 56 for connection diagrams. See page 35 for dimensions. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. 12
15 Close Coupled Pump Motors with AEGIS Grounding Ring These motors are designs and manufactured for commercial and industrial pump applications where adjustable speed drives are utilized. They feature Class H insulation with an AEGIS bearing protection ring installed internally. Motors include oversized ball bearings with locked drive end construction to minimize endplay. All models meet or exceed Premium efficiencies, are Inverter Ready, and have a 3-year warranty. TEFC Totally Enclosed Fan Cooled Foot Mounted, 230/460 Volts, Three Phase, 3-20 Hp Hp kw RPM Catalog Number High V Locked Rotor Torque Lb. Ft. Efficiency % Power Factor % Bearings 1/2 3/4 1/2 3/4 DE ODE Volt Code C Dim. Conn. Diag. No JM EJMM3610T-G E CD JM EJMM3611T-G E CD JM EJMM3613T-G E CD JM EJMM3615T-G E CD / JM EJMM3709T-G F CD / JM EJMM3710T-G E CD JM EJMM3711T-G E CD JM EJMM3714T-G E CD JM EJMM2394T-G E CD JM EJMM2333T-G E CD JM EJMM4106T-G E CD JM EJMM2334T-G E CD0005 NOTE: Volt Code: E= /460 volts; E1=230/460 volts, usable at 208 volts. Shaded ratings are cast iron frames. See page 34 for Layout drawing. See page 56 for Connection Diagrams. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. Close Coupled Pump Motors with AEGIS Grounding Ring ODP Open Drip Proof Foot Mounted, 230/460 Volts, Three Phase, 3-15 Hp Hp kw RPM Catalog Number High V Locked Rotor Torque Lb. Ft. Efficiency % Power Factor % Bearings 1/2 3/ JM EJMM3116T-G E CD / JM EJMM3154T-G E CD JM EJMM3157T-G E CD JM EJMM3158T-G E CD JM EJMM3211T-G E CD JM EJMM3212T-G E CD JM EJMM3218T-G E 18 CD / JM EJMM3219T-G E 16.5 CD / JM EJMM3311T-G F CD JM EJMM3312T-G E CD JM EJMM3313T-G F CD JM EJMM3314T-G F CD JM EJMM2513T-G E CD0180 NOTE: Volt Code: E= /460 volts; E1=230/460 volts, usable at 208 volts; F=230/460 volts. See page 35 for Layout drawing. See page 56 for Connection Diagrams. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. 1/2 3/4 Volt Code C Dim. Conn. Diag. No DE ODE
16 Close Coupled Pump Washdown Duty Motors Baldor close-coupled pump Washdown Duty motors are for commercial and industrial water pump applications, or food processing applications that are exposed to high-pressure washdowns. Features over-sized ball bearings with locked drive end construction to minimize shaft movement. Contaminant and moisture-prevention features include a moisture sealant on the bolt heads between the frame and endplates, neoprene gaskets, and a Forsheda running contact V-ring. TEFC - Totally Enclosed Fan Cooled, TENV - Totally Enclosed Non-Ventilated - 230/460 Volts, Three Phase, 1-15 Hp Hp kw RPM Encl. Catalog Number High V Locked Rotor Torque Lb. Ft. Efficiency % Power Factor % Bearings 1/2 3/4 1/2 3/ JM TENV JMWDM3546T E CD JM TEFC JMWDM3550T E CD JM TENV JMWDM3554T E CD JM TEFC JMWDM3555T E CD JM TEFC JMWDM3558T E CD JM TEFC JMWDM3559T E CD JM TEFC JMWDM3611T E CD JM TEFC JMWDM3613T E CD JM TEFC JMWDM3615T E CD JM TEFC JMWDM3616T E CD JM TEFC JMWDM3710T E CD JM TEFC JMWDM3711T E CD JM TEFC JMWDM3714T E CD JM TEFC JMWDM3713T E CD0005 NOTE: Volt Code: E = /460V, 60Hz See page 56 for Connection Diagram. See page 37 for dimensions. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. DE ODE Volt Code C Dim. Conn. Diag. No. Close Coupled Pump SSE Super-E Stainless Steel Encapsulated Motors 14 TEFC - Totally Enclosed Fan Cooled, TENV - Totally Enclosed Non-Ventilated - 230/460 Volts, Three Phase, 1-10 Hp Hp kw RPM Encl. Catalog Number High V Locked Rotor Torque Lb. Ft. Efficiency % Power Factor % Bearings 1/2 3/4 1/2 3/ JM TENV JMSSEWDM3546T E CD JM TENV JMSSEWDM3550T E CD JM TEFC JMSSEWDM3554T E CD JM TEFC JMSSEWDM3555T E CD JM TEFC JMSSEWDM3558T E CD JM TEFC JMSSEWDM3559T E CD JM TEFC JMSSEWDM3611T E CD JM TEFC JMSSEWDM3613T E CD JM TEFC JMSSEWDM3615T E CD JM TEFC JMSSEWDM3709T E CD JM TEFC JMSSEWDM3710T E CD JM TEFC JMSSEWDM3711T E CD JM TEFC JMSSEWDM3714T E CD0180 NOTE: Volt Code: E = /460V, 60Hz; E1 = 230/460V, 60Hz, usable at 208V See page 56 for Connection Diagrams. See page 37 for dimensions. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. DE ODE Volt Code C Dim. Conn. Diag. No.
17 Baldor Reliance Jet Pump Motors Baldor Reliance jet pump motor are available in open drip proof or totally enclosed industrial steel band constructions. Motor construction can be tailored for specific applications and industries such as food processing, washdown applications or explosion-proof enclosures for pumps in hazardous areas. Fan cover designed to provide maximum cooling and quiet operation Bi-directional cooling fan designed for low friction and windage losses Antifriction ball bearings for long motor life End turn lacing on both ends of the winding prevents electrical failures Locked bearing construction reduces shaft endplay Gasketed conduit box to prevent moisture ingress Electrical grounding terminal inside conduit box Heavy-gauge steel frame construction High-pressure die cast aluminum rotor coated to reduce corrosion Mobil Polyrex EM grease for greater bearing protection and improved lubrication life Non-drive end shaft extension is slotted to aid in pump assembly and maintenance. Drive end shaft extension made of 400 series stainless steel and threaded meeting 56J dimensions. 15
18 Jet Pump Motors Single Phase - ODP Jet Pump motors are designed for Residential and industrial pump applications. Construction features include a sturdy steel frame, cast aluminum end plates with steel bearing seat inserts for mechanical reliability. Opposite drive end shaft is slotted for convenience. Open Drip Proof, 115/230 Volt, Single Phase, 1/3-3 HP Hp kw RPM High V Efficiency % Power Factor % Bearings Catalog Volt Torque Number Code S.F. C Conn. Locked Dim. Diag. No. Notes Rotor Lb. Ft. 1/2 3/4 1/2 3/4 DE ODE 56J, Foot Mounted 1/ J CJL1205A B CD0307-1/ J CJL1301A B CD0307-1/ J CJL1303A B CD0307-1/ J CJL1304A B CD / J CJL1306A B CD0307-3/ J CJL1307A B CD J CJL1309A B CD J CJL1313A B CD J CJL1317A B CD J, Footless 1/ J JL1205A B CD0203-1/ J JL1301A B CD / J JL1303A B CD0307-1/ J JL1304A B CD / J JL1306A B CD0307-3/ J JL1307A B CD J JL1309A B CD J JL1313A B CD J JL1317A B CD J JL1323A C CD C, Footless 1/ C VL1205A B CD0052-1/ C VL1301A B CD / C VL1303A B CD0052-1/ C VL1304A B CD / C VL1306A B CD0052-3/ C VL1307A B CD C VL1309A B CD C VL1318A B CD C VL1313A B CD C VL1317A B CD C VL1323A C CD NOTE: Volt Code: B = 115/230V, 60Hz; C = 230V, 60Hz; D= V, 60Hz 30 Usable at 208 Volts All threaded shaft single phase motors are connected single rotation CCW when viewing drive end. See pages 58, 59 and 60 for connection diagrams. See page 41 for dimensions. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. 16
19 Jet Pump Motors Single Phase - TEFC Jet Pump motors are designed for Residential and industrial pump applications. Construction features include a sturdy steel frame, cast aluminum end plates with steel bearing seat inserts for mechanical reliability. Opposite drive end shaft is slotted for convenience. Totally Enclosed Fan Cooled, 115/230 Volt, Single Phase Phase, 1/3-2 HP Hp kw RPM Catalog Number High V Locked Rotor Torque Lb. Ft. NOTE: Volt Code: B = 115/230V, 60Hz 20 Class F Insulation 30 Usable at 208 Volts All threaded shaft single phase motors are connected single rotation CCW when viewing drive end. See pages 59 and 60 for connection diagrams. See page 42 for dimensions. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. Efficiency % Power Factor % Bearings 1/2 3/4 1/2 3/4 DE ODE Volt Code S.F. C Dim. Foot Mounted 1/ J CJL3501A B CD / J CJL3504A B CD / J CJL3507A B CD Footless 1/ J JL3405A B CD0094-1/ J JL3501A B CD J JL3503A B CD J JL3504A B CD J JL3506A B CD J JL3507A B CD J JL3509A B CD J JL3510A B CD / J JL3513A B CD / J JL3514A B CD0098A J JL3515A B CD J JL3516A B CD Conn. Diag. No. Notes 17
20 Jet Pump Motors Three Phase - ODP Jet Pump motors are designed for Residential and industrial pump applications. Construction features include a sturdy steel frame, cast aluminum end plates with steel bearing seat inserts for mechanical reliability and a stainless steel threaded shaft for long life. Opposite drive end shaft is slotted for convenience. Open Drip Proof, 230/460 Volt, Three Phase, 1/3-3 HP Hp kw RPM Catalog Number High V Locked Rotor Torque Lb. Ft. Efficiency % Power Factor % Bearings 1/2 3/4 1/2 3/4 NOTE: Volt Code: E = /460V, 60Hz; E1 = 230/460V, 60Hz, usable at 208V 1 Class F Insulated Motor with 1.15 Service Factor or higher that operates within Class B temperature limits at rated horsepower. 20 Class F Insulation All threaded shaft single phase motors are connected single rotation CCW when viewing drive end. See page 56 for connection diagrams. See page 43 for dimensions. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. DE ODE Volt Code S.F. C Dim. Footless 1/ J JM E CD0005-1/ J JM E CD0005-1/ J JM E CD0005-3/ J JM E CD0005-3/ J JM E CD J JM E CD J JM E CD0005 1, / J JM E CD / J JM E CD J JM E CD J JM E CD Foot Mounted 1/ J CJM E CD0005-1/ J CJM E CD0005-1/ J CJM E CD0005-3/ J CJM E CD0005-3/ J CJM E CD J CJM E CD / J CJM E CD J CJM E CD J CJM E CD Conn. Diag. No. Notes 18
21 Jet Pump Motors Three Phase - TEFC Jet Pump motors are designed for Residential and industrial pump applications. Construction features include a sturdy steel frame, cast aluminum end plates with steel bearing seat inserts for mechanical reliability and a stainless steel threaded shaft for long life. Opposite drive end shaft is slotted for convenience. Totally Enclosed Fan Cooled, 230/460 Volt, Three Phase, 1/3-3 HP Hp kw RPM Catalog Number High V Locked Rotor Torque Lb. Ft. Efficiency % Power Factor % Bearings 1/2 3/4 1/2 3/4 DE ODE Volt Code S.F. C Dim. Footless 1/ J JM E CD0005-1/ J JM E CD0005-1/ J JM E CD0005-1/ J JM E CD0005-3/ J JM E CD0005-3/ J JM E CD J JM E CD J JM E CD / J JM E CD / J JM E CD J JM E CD J JM E CD J JM E CD0005 1, 20 Foot Mounted 1/ J CJM E CD0005-3/ J CJM E CD NOTE: Volt Code: E = /460V, 60Hz; E1 = 230/460V, 60Hz, usable at 208V 1 Class F Insulated Motor with 1.15 Service Factor or higher that operates within Class B temperature limits at rated horsepower. 20 Class F Insulation All threaded shaft single phase motors are connected single rotation CCW when viewing drive end. See page 56 for connection diagrams. See page 44 for dimensions. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. Jet Pump Explosion-Proof Motors Baldor offers explosion-proof motors available from stock in single and three phase, 1/2 hp through 2 hp, in frame 56J. They are UL and CSA approved for Class I Group D and Class II Group F and G. Single Phase, 115/230 Volt, 1/2-2 Hp Hp kw RPM Catalog Number XP Cls & Grp XP Temp Code High V Locked Rotor Torque Lb. Ft. Efficiency % Power Factor % 1/2 3/4 1/2 3/ J JL5003A 2 T / CD J JL5006A 2 T / CD J JL5009A 2 T / CD J JL T / CD J JL T / CD0001 Three Phase, 230/460 Volt, 1-2 Hp Hp kw RPM Catalog Number XP Cls & Grp XP Temp Code High V Locked Rotor Torque Lb. Ft. Efficiency % Power Factor % 1/2 3/4 1/2 3/ J JM T / CD J JM T / CD J JM T / CD Class I, Group D, Class II, Group F & G CAUTION: These Explosion-proof motors are not suitable for use with adjustable speed drives. 30 Usable at 208 Volts Inverter Duty Explosion-proof motors must be used. All threaded shaft single phase motors are connected single rotation CCW when viewing drive end. See pages 56 and 57 for connection diagrams. See page 49 for dimensions. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. See inside back cover for explosion-proof classification information Voltage Voltage C Dim. C Dim. Conn. Diag. No. Conn. Diag. No. Conn. Diag. No. Notes Notes Notes 19
22 Close-Coupled Pump, Explosion-Proof Motors Where close-coupled pump shaft configurations are required in hazardous locations, Baldor offers explosion-proof motors available from stock in three phase, 3 hp through 10 hp, in frames 145JM through 215JM. They are UL and CSA approved for Division 1, Class I, Group D, Class II, Group F & G, and are rated at a 1.0 Service Factor. Three Phase, 230/460 Volt, 3-10 Hp Hp kw RPM Catalog Number XP Cls & Grp XP Temp Code High V Locked Rotor Torque Lb. Ft. Efficiency % Power Factor % 1/2 3/4 1/2 3/ JM JMM7075T 1 T2C / CD JM JMM7026T 1 T2C / CD JM JMM7072T 1 T2C / CD JM JMM7073T 1 T2C / CD JM JMM7045T 1 T2C / CD JM JMM7074T 1 T2C / CD Class I, Group D CAUTION: These Explosion-proof motors are not suitable for use with adjustable speed drives. See page 56 for connection diagrams. See page 49 for dimensions. Inverter Duty Explosion-proof motors must be used. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. See inside back cover for explosion-proof classification information Voltage C Dim. Conn. Diag. No. Close-Coupled Pump, Drill Rig Duty, Explosion-Proof Motors Baldor motors designed for on and off shore drill rig service, bulk fuel terminals, and transfer stations where close-coupled pump shaft configurations are required. For use in high humidity hazardous-duty applications driving pumps, compressors, blowers and fans. These motors feature Labyrinth-type recessed shaft slinger for increased bearing protection. Explosion-proof breather/drain to prevent build up of condensation. Class F insulation. Corrosion resistant finish with two part epoxy coating. Rated for 55 C ambient and 1.15 service factor (EJPM71170T-I has 1.0 S.F.). UL and CSA approved for Division 1, Class I, Group C & D. Available from stock 3 hp to 10 hp with 182JP to 184JP mounting. Three Phase, 230/460 Volt, 3-10 Hp Hp kw Actual RPM Catalog Number XP Cls & Grp XP Temp Code High V Locked Rotor Torque Lb.Ft. Efficiency % 1/2 3/4 1/2 pf Power Factor % JP EJPM7142T-I 4 T3C / CD0005 1, 19, JP EJPM7144T-I 4 T3C / CD0005 1, 19, TCZ EJPM71147T-I 4 T3C / CD0005 1, 19, TCZ EJPM71170T-I 4 T3C / CD , 97 4 Class I, Group C & D CAUTION: These Explosion-proof motors are not suitable for use with adjustable speed drives. 1 Class F insulated motor with 1.15 Service Factor or higher that operates within Class "B" temperature limits at rated horsepower Inverter Duty Explosion-proof motors must be used /50 Hertz motor. 60 Hertz data shown, contact your local Baldor Reliance office for 50 Hertz data 30 Usable at 208 volts 97 One size smaller flange and shaft See page 56 for connection diagrams. See page 50 for dimensions. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. See inside back cover for explosion-proof classification information 3/4 pf pf Voltage C Dim. Conn. Diag. No. Notes 20
23 Square Flange Pump Motor Single Phase - ODP Square flange pump motors are designed for drop in replacement in pump applications where square flange mounting plate is required,such as swimming pools. They have a stainless steel shaft extension for long life, a drip cover and slotted opposite drive end shaft for convenience. Open Drip Proof, 115/230 Volt, 1/2-2 HP Hp kw RPM Catalog Number High V Locked Rotor Torque Lb. Ft. NOTE: Single Phase Volt Code: B = 115/230V, 60Hz Three Phase Volt Code: E = /460V, 60Hz; E1 = 230/460V, 60Hz, usable at 208V 30 Usable at 208 Volts See pages 56 and 59 for connection diagrams. See page 45 for dimensions. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. Efficiency % Power Factor % Bearings 1/2 3/4 Single Phase 1/2 3/4 DE ODE Volt Code S.F. C Dim. 1/ Y JSL325A B CD / Y JSL425A B CD Y JSL525A B CD / YZ JSL625A B CD YZ JSL725A B CD Three Phase 1/ YZ JSM E CD / YZ JSM E CD YZ JSM E CD / YZ JSM E CD YZ JSM E CD Conn. Diag. No. Notes SAE Hydraulic Pump Motors Three Phase - TEFC Continuous Duty Baldor SEA Hydraulic Pump mount motors are design to mount into hydraulic pumps for lifts, trash compactors and other machinery. They include a rigid base mount with SAE A or B pump mount face and shaft. The conduit box is F3 top-mounted for easy connections. These motors are designed for continuous duty but may also be used on intermittent duty applications. Their electrical design includes a robust Class F Insulation and 1.15 Service Factor. Totally Enclosed Fan Cooled, 230/460 Volts, Three Phase, 5-10HP Hp kw RPM Catalog Number High V Locked Rotor Torque Lb. Ft. NOTE: Volt Code: E = /460V, 60Hz 35 Design A See page 56 for connection diagrams. See page 46 for dimensions. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. Efficiency % Power Factor % Bearings 1/2 3/4 1/2 3/ TYZ HPM3615T E CD TYZ HPM3710T E CD TYZ HPM3714T E CD DE ODE Volt Code C Dim. Conn. Diag. No. Notes 21
24 Vertical P-Base Motors Applications Baldor Reliance solid shaft Vertical P-Base AC motors are the perfect power mates for centrifugal pumps, sump pumps, turbine pumps, in-line process pumps, fans, aerators, mixers, autoclaves, cooling towers and similar applications in general industrial environments. Additional performance and protection features are available in standard modification packages for customized applications in special environments such as petroleum refining, chemical, processing and water treatment. Baldor Reliance LP & VP motors are designed to meet the American Petroleum Institute Standard 610. Efficiency There is no need to limit your energy savings to horizontal applications. Significant energy savings and short pay-back periods are also available to you for vertical applications. Baldor Reliance Vertical AC motors are available in Super-E, Premium efficient designs. The same engineering and manufacturing knowledge and experience that go into every horizontal Super-E motor also go into every Vertical P-Base Super-E motor produced. The Super-E design is capable of inverter operation at 1.0 S.F. For selection and application assistance, contact your local Baldor office. Enclosures Baldor Reliance Vertical P-Base AC motors are available in a variety of enclosures and thrust values to suit your application. All frames are cast iron. For the harshest industrial environments, we offer a Severe Duty mechanical package especially designed to meet the challenges of severe applications. Premium features protect motor components from chemicals, corrosion, and abrasives, extending motor life and improving performance. Baldor Reliance Vertical P-Base AC motors are also available with special Arctic Duty motor construction. This enables the motors to operate successfully in temperatures down to -60 C. Arctic Duty Vertical motor construction is available in 182T through 449T with UL listing for Class 1, Groups C and D and through 5000 frame with non-ul listed construction. Baldor Reliance Vertical AC motors are available for normal thrust ( HP), medium thrust ( LP), extended thrust in-line pump ( LP) and exteded thrust vertical turbine pump ( VP) ratings. All motors are manufactured to tolerances which meet or exceed requirements in every frame size and horsepower rating. Contact your local Baldor office for additional infomration, pricing and availability. Enclosed Motors Thrust values based on L10 = 17,500 hours Normal Thrust Medium Thrust High Thrust Thrust (lbs.) (lbs.) (lbs) Direction 4 pole 2 pole 4 pole 2 pole 4 pole 2 pole Into Motor Out of Motor Into Motor Out of Motor Into Motor Out of Motor Into Motor Out of Motor Into Motor Out of Motor Into Motor Out of Motor Into Motor Out of Motor Into Motor Out of Motor Into Motor Out of Motor Open Motors Thrust values based on L10 = 17,500 hours Normal Thrust Medium Thrust High Thrust Thrust (lbs.) (lbs.) (lbs) Direction 4 pole 2 pole 4 pole 2 pole 4 pole 2 pole Into Motor Out of Motor Into Motor Out of Motor Into Motor Out of Motor Into Motor Out of Motor Into Motor Out of Motor Into Motor Out of Motor
25 Vertical P-Base Motors Three Phase - TEFC These motors are designed and manufactured for normal, medium and high thrust in-line pump applications typical of waste water treatment plants, petro chemical industries, pulp and paper mills and agricultural irrigation. Motor design includes severe duty construction with corrosion-resistant epoxy finish, cast-iron construction, designed for vertical mounting. Rotatable conduit box, stainless steel nameplates, shaft seals. Energy efficient windings. Two lifting lugs for balanced lifting. All Baldor-Reliance Vertical P-Base motors have 1.15 Service Factor and are Inverter-Ready. Normal thrust VHECP motors meet or exceed Premium efficiency levels. TEFC - Totally Enclosed Fan Cooled, 230/460 Volts, Three Phase, 3-75 Hp Hp kw RPM Catalog Number High V F.L. Torque Lb. Ft. NOTES: Volt Code: E = /460V, 60Hz; E1 = 230/460V, 60Hz, usable at 208V 35 = Design A See pages 56 and 57 for connection diagrams. See page 47 for dimensions. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. F.L. L.R. Efficiency % Power Factor % Bearings Max Down 1/2 3/4 F.L. 1/2 3/4 F.L. DE ODE Thrust Lbs. Normal Thrust HP VHECP3660T E CD HP VHECP3661T E CD HP VHECP3663T E CD HP VHECP3665T E CD HP VHECP3769T E CD HP VHECP3770T E CD HP VHECP3771T E CD HP VHECP3774T E CD HP VHECP2394T E CD HP VHECP2333T E CD HP VHECP4106T E CD HP VHECP2334T E CD HP VHECP4107T E CD HP VHECP4103T E CD HP VHECP4108T E CD HP VHECP4104T E CD HP VHECP4109T E CD HP VHECP4110T E CD HP VHECP4114T E CD HP VHECP4115T E CD HP VHECP4310T E HP VHECP4314T E HP VHECP4313T E HP VHECP4316T E Volt Code C Dim. Conn. Diag. No. Notes Shaded ratings are cast iron frames. 23
26 TEFC - Totally Enclosed Fan Cooled, 230/460 Volts, Three Phase, 3-75 Hp Hp kw RPM Catalog Number High V F.L. L.R. F.L. Torque Lb. Ft. Efficiency % Power Factor % Bearings Max Down 1/2 3/4 F.L. 1/2 3/4 F.L. DE ODE Thrust Lbs. Medium Thrust LP VLCP3660T QJ E CD LP VLCP3661T QJ E CD LP VLCP3663T QJ E CD LP VLCP3665T QJ E CD LP VLCP3769T QJ E CD LP VLCP3770T QJ E CD LP VLCP3771T QJ E CD LP VLCP3774T QJ E CD LP VLCP2394T QJ E CD LP VLCP2333T QJ E CD LP VLCP4106T QJ F CD LP VLCP2334T QJ E CD LP VLCP4107T QJ E CD LP VLCP4103T QJ E CD LP VLCP4108T QJ E CD LP VLCP4104T QJ E CD LP VLCP4109T QJ E CD LP VLCP4110T QJ E CD High Thrust VP VPCP4114T QJ E CD VP VPCP4115T QJ E CD VP VPCP4310T E VP VPCP4314T E VP VPCP4313T E VP VPCP4316T E NOTES: Volt Code: E = /460V, 60Hz; E1 = 230/460V, 60Hz, usable at 208V 35 = Design A See pages 56 and 57 for connection diagrams. See page 47 for dimensions. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. Volt Code C Dim. Conn. Diag. No. Notes Shaded ratings are cast iron frames. 24
27 Vertical P-Base Motors Three Phase - ODP These pump motors are well suited for normal thrust, solid shaft pumping applications where an open enclosure is required. They are capable of 100% thrust in either direction. Rugged cast iron construction includes frame and endplates. The motor has two lifting lugs for balanced lifting and a rotatable conduit box for easy connections. An epoxy finish and stainless nameplate provide long life. These motors have Class F insulation with a 1.15 service factor and operate within Class B temperature limits at rated load. Open Drip Proof, 230/460 Volts, Three Phase, 3-60 Hp Hp kw RPM Efficiency % Power Factor % Bearings Catalog F.L. High V Torque Volt C Conn. Diag. Number Lb. Ft. 1/2 3/4 F.L. 1/2 3/4 F.L. Code Dim. DE ODE No. F.L. L.R. Notes Normal Thrust HP VHM3210T E CD HP VHM3211T E CD HP VHM3212T E CD HP VHM3218T E CD HP VHM3219T E CD HP VHM3311T E CD HP VHM3312T E CD HP VHM3313T E CD HP VHM3314T E CD HP VHM2513T E CD HP VHM2514T E CD HP VHM2515T E CD HP VHM2516T E CD HP VHM2531T E CD HP VHM2534T E CD HP VHM2535T E CD HP VHM2538T E CD HP VHM2539T E CD HP VHM2542T E CD HP VHM2543T E CD HP VHM2546T E CD NOTES: Volt Code: E = /460V, 60Hz; E1 = 230/460V, 60Hz, usable at 208V 35 = Design A See pages 56 and 57 for connection diagrams. See page 48 for dimensions. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. Shaded ratings are cast iron frames. 25
28 Submersible Motors Baldor offers submersible motors serving both municipal and industrial wastewater markets for both wet & dry pit applications. Wet pit motors use the effluent for cooling and can run 15 minutes in air. Dry pit motors are designed to run continuously in air or submerged when properly applied. Baldor also offers designs suitable for rugged slurry pump applications, aerators and mixers. These motors are tough and corrosion resistant, with cast iron frame and end shields, 316 stainless steel hardware and 416 stainless steel shaft. In addition, they are U/L listed and CSA certified for Class 1 Division 1 Groups C & D, with a T3C temperature code. Manufactured with a Type 21 tandem seal design, it will withstand 100 psi (sum of operating depth and reflected pump pressure) at the lower/outer seal. Dual moisture probes will detect any moisture in the oil chamber. These motors are covered by a 5 year prorated warranty. Submersible Motor Features: Energy efficient and Premium efficient designs 1.15 S.F. on Sine Wave, 1.0 S.F. on inverter Class F insulation UL & CSA Listed on Sine wave power for Div. 1, Class I, Group C & D, T3C Temp Code 10:1 Variable Torque capable on Inverter with UL & CSA Listing for Div. 1, Class I, Group D, T2A Temp Code Cast Iron Construction P-Base mounting flange 416 Stainless Steel Shaft Type 21 carbon ceramic mechanical shaft seals. Outer/lower seal must be lubricated by the pump on Dry Pit applications. O-rings and Sealed fits in stator housing and end plates Non-wicking, potted cable cap assembly securely attaches and seals the power leads to the frame. Cable cap design allows for easy removal and reconnection of the power cable. Drive end oil chamber provides a barrier against moisture ingress into the bearings as well as lubricating the upper seal. Oil chamber is filled prior to shipment. Moisture probes mounted in oil chamber to detect ingress of moisture. Moisture control relay supplied by customer. (2) Integral cast in lifting provisions for easy, balanced lifting and mounting of the motor Deep groove Conrad type ball bearings, Class 3 fit per AFBMA std. 20 (2) N.C. Thermostats 416 Corrosion resistant stainless steel nameplate and exterior hardware 25 foot power & control cables Neoprene jacketed power and control cables 5 Year Prorated Warranty from date of Manufacture. Common Options: Class H insulation system Inner and outer seals options Shaft materials One size smaller flange and shaft Special paint (Coal tar epoxy paint) Cable lengths to 100 feet (Longer lengths require approval) Water Jacket Design (to reduce frame size requirements) Labyrinth Slinger on D.E. suitable for XP Submersible Motors - Capabilities Maximum Horsepower per frame (based on 1800 rpm) for UL Approved and Non-UL Approved designs Submersible Motors - Bearing Thrust Capabilities Minimum bearing L10 life = 17,500 hours with the below listed conditions min in air Three Phase Continuous in air Efficient 15 min in air 15 min in air Single Phase Continuous in air 180TY TY TY TY TY TY TY 210TY 250TY 320TY 360TY RPM Max Impeller Weight Max Radial Including Impeller Max Axial (In or Out) Thrust Radial Distance from Flange Face (lbs) (lbs) (lbs) (inches) Note: Max Axial load tested in combination with Max Radial load Size 7222 Back-to-Back angular contact bearings available on 360 frames for higher thrust load capabilities.
29 Submersible Motor Construction Potting: Epoxy-filled, non-wicking cable cap assembly Exterior Threads: To provide conduit or added cable seal or support Power and Control Cables: Neoprene jacketed; 25 feet of cable as standard; other lengths available Motor Leads: Class F temperature rated lead material. Leads are butt spliced within epoxy filled cable cap to provide secure non-wicking design. Integral Lifting Lugs: Construction: All cast iron Bearings: Single row, deep groove or double row angular contact, Conrad type Stator: Double dip and bake process insulation system Class F minimum Inner and Outer Seals: Two independently mounted Type 21 mechanical face type seals. O-Rings (Qty 4): Sealed deep groove joints/registers in stator housing and end plates. Oil Chamber: Acts as a barrier to trap moisture and provide sufficient time for shut down. Also provides lubrication for upper seal Moisture Probes: Mounted in oil chamber to detect ingress of moisture. Moisture control relay supplied by customer. Shaft: 416 Stainless Steel and hardware Available Slurry Seal Design: Pumping highly viscous fluids is the most demanding type of pumping application on shaft seal life. It requires a better sealing solution to protect the seals from the abrasive fluid. Unlike the tandem inner and outer seal in typical submersible applications, slurry seals are contained completely within the motor s oil chamber to protect the seals. 27
30 Submersible Explosion-Proof Motors Baldor Submersible motors are designed for wet pit applications that require Continuous Duty in water/sewage and 15 Minute Duty in air. Single phase designs are suitable for use on Sine wave power only. Connection box and capacitors supplied with single phase motors for customer remote mounting. Three Phase designs are suitable for 10:1 Variable torque for Division 1, Class I, Group D, T2A temperature code. Single Phase, 115/230 Volt, 1-5 Hp Hp kw RPM Catalog Number XP Cls & Grp XP Temp Code High V Locked Rotor Torque Lb. Ft. Efficiency % Power Factor % 1/2 3/4 PF PF PF 1/2 3/4 Motor Connected Voltage Voltage Dim Sheet Conn. Diag. Number TY C18G T3C / TY C18G T3C / TY C18G T3C / TY C18G T3C / TY C18G T3C / TY C18G T3C / TY C18G T3C / TY C21G T3C / TY C21G T3C Notes 28 Three Phase, 230/460 Volt, Hp Hp kw RPM Catalog Number XP XP Cls Temp & Code Grp High V Locked Rotor Torque Efficiency % Power Factor % 1/2 3/4 1/2 3/4 PF PF PF Motor Voltage Connected Voltage Dim Sheet Conn. Diag. Number Lb. Ft TY P18G T3C / TY P18G T3C / TY P18G T3C / TY P18G T3C / TY P18G T3C / TY P18G T3C / TY P18G T3C / TY P18G T3C / TY P18G T3C / TY P18G T3C / TY P21G T3C TY P18G T3C / TY P18G T3C / TY P21G T3C / TY P21G T3C / TY P21G T3C / TY P21G T3C / TY P21G T3C / TY P21G T3C / TY P25G T3C / TY P21G T3C / TY P21G T3C / TY P25G T3C / TY P25G T3C / TY P25G T3C / TY P25G T3C / TY P25G T3C / TY P32G T3C TY P25G T3C TY P32G T3C TY P32G T3C TY P32G T3C TY P32G T3C TY P32G T3C TY P36G T3C TY P36G T3C TY P36G T3C Class I, Group C & D 82 Single voltage motor. Cannot reconnect. 97 One size smaller flange and shaft See pages 54, 55, 56 and 57 for connection diagrams. See pages 51, 52, and 53 for dimensions. Efficiencies shown are nominal. Data subject to change without notice. Contact Baldor for certified data. Notes
31 Immersible Motors Baldor Reliance custom Immersible motors are designed for use in non-hazardous area Dry Pit applications where the possibility of flooding exists. Such applications are typical in the industrial water and wastewater industry. The motor features totally enclosed, blower-cooled enclosures and are designed with a unique sealing system that exceeds IP67 enclosure requirements. This system allows reliable operation for a period of two weeks while submerged under a maximum depth of thirty feet of water. Immersible motors save customers from having to use more expensive submersible design motors. They also save on installation costs by eliminating support structure and shaft extensions typically required to mount the pump motor above the high water level of the pit. Baldor Reliance Immersible motors reduce down time and replacement costs after each submersion. Non immersible motor designs would have to be rebuilt or replaced after being submerged. The immersible motor solution only needs to pass a routine inspection of the bearings and seals on the main motor. On 250T frames and up, there is minimal replacement costs of the 1/2HP blower motor to get back up and running. Traditional Dry Pit Pump installation: A standard TEFC motor is mounted more than 20 feet above pump. Immersible Motor Solution: The motor mounts directly on pump. When submerged it will operate for two weeks at max depth of 30 feet. Construction & installation costs are reduced by eliminating support structure for non-immersible motors. Immersible motors are the ideal choice for industrial pumping applications where the possibility of flooding exists. Contact your local Baldor office for pricing and availability. 29
32 Immersible Motor Operating Conditions: Continuous in Air Non-hazardous area applications 14 days submerged in up to 30 feet of water Suitable for 10:1 Variable Torque speed Range on inverter power. Immersible Motor Features: Premium efficient designs P-Base or C-face mounting Vertical or horizontal mounting available Cast Iron Construction (2) vertical lifting provisions for easy, balanced lifting and mounting of the motor Single shielded, deep groove Conrad type bearings, Class 3 fit per AFBMA std ,000 Hr L10 life min., for flexible direct coupled applications, normal thrust Top mounted thrust bearing designs available to meet HP, LP & VP thrust requirements. Top mounted bearing in LP or VP designs meets the requirements of A.P.I. Spec # 610 Dual Lip Seals with grease packed cavity on drive end to prevent moisture entry The motor exceeds the IP67 requirements of two weeks submersion at a depth of thirty feet. Patented immersible motor sealing system. Includes Submersible type cable cap assembly to protect motor connections from moisture while allowing for easy removal of the power cable Potted leads between c/box and frame seals the motor frame when submerged 10:1 VT speed range when operating on adjustable frequency power Winding temperature detectors (thermostats) to protect against blower motor shutoff while running in air Space heater to prevent build up of condensation inside the motor frame Corrosion resistant stainless steel nameplate and exterior hardware 25 foot power cable, other lengths available 18 Month Warranty from date of Manufacture Ratings Capabiltites Chart 460Volt, 3 Phase designs 3600 RPM 1800 RPM 1200 RPM 900 RPM HP NOTES: 210 frame are TENV 250 and above are TEBC Immersible motors are the ideal choice for industrial pumping applications where the possibility of flooding exists. Contact your local Baldor office for pricing and availability. 30
33 Immersible Motor Construction Features Separately powered 1/2 HP Baldor Reliance Washdown Duty blower motor(250 & up). Operates continuously in air. Connected to customer supplied float switch for safe shut-off prior to submersion. Blower motor is replaced after being submerged. Drip Cover and Safety screen protects the fan from damage. Space Heaters prevent condensation build up inside of the motor frame. All mating fits have rabbet joints with O-rings to ensure a watertight design. Sealing compound on fits and hardware Totally Enclosed Blower Cooled enclosure (TENV in 210 frame) eliminates fan end shaft extension hole in the frame for better sealing. Meets or exceeds IP67 enclosure requirements. All mounting hardware shall be high strength, SAE Grade 5, and plated for protection. Normal Thrust applications use single shielded bearing construction, deep groove Conrad type, with a Class 3 internal fit conforming to AFBMA std 20. Bearing L10 life of 100,000 hrs minimum for flexible direct coupled applications. Grease inlet and outlet on both ends of motor. 25 Feet of power cable is provided as standard. (2) Vertical lifting ears provide for easy balanced lifting and mounting of the motor. Corrosion resistant stainless steel nameplate and exterior hardware. Conduit box uses Submersible motor cable cap design to securely protect motor conections from water ingress while allowing the power cable to be removable. Features include: Epoxy filled non-wicking cap assembly and O-rings between cap and box. Premium efficient electrical design windings provide for lower cost operation. Rugged finned cast iron construction provides maximum cooling for smaller motor design and protects the motor while operating harsh environments. Potted leads between frame and conduit box seals the motor frame when submerged. N.C. Thermostats embedded in the motor winding protect the motor from overheating if the Blower motor is shut off while operating in air. Dual lip seals with grease packed cavity on drive end. 31
34 Dimensions Close-Coupled Pump Motors TEFC JM Mount 143JM - 326JM C EQ AH ET ES BB KEY XO AB P NAMEPLATE U BD O EL EM AK D 4 HOLES TAP BF AJ DIA. H HOLES 2F 2F B BA EN TAP AA LEAD HOLE E A E A B D E 2F H Key O P U AA AB AH AJ Steel Band Construction BF Tap AK BA BB BD XO 143JM / JM / JM / JM / JM / JM / Cast Iron 254JM / JM / JM / JM / JM / JM / Shaft Dimensions EL EM EN EQ ES ET Steel Band Construction 143JM x JM x JM x JM x JM x JM x Cast Iron 254JM x JM x JM x JM x JM x JM x NOTE: Dimension for reference only. Contact Baldor or for a detailed dimension drawing for your specific catalog number. 32
35 Dimensions Close-Coupled Pump Motors TEFC JP Mount 215JP - 326JP C EQ AH ET ES BB KEY XO AB P NAMEPLATE U BD O EL EM AK D 4 HOLES TAP BF AJ DIA. H HOLES 2F 2F B BA EN TAP AA LEAD HOLE E A E A B D E 2F H KEY O P U AA AB AH AJ Steel Band Construction BF TAP AK BA BB BD XO 215JP / Cast Iron 254JP / JP / JP / JP / JP / JP / Shaft Dimensions EL EM EN EQ ES ET Steel Band Construction 215JP x Cast Iron 254JP x JP x JP x JP x JP x JP x NOTE: Dimension for reference only. Contact Baldor or for a detailed dimension drawing for your specific catalog number. 33
36 Dimensions Close-Coupled Pump Motors Totally Enclosed, Fan-Cooled 254JM through 326JM A B D E 2F H Key 0 P U AA AB AC AJ AK BA BB BD 254JM-JP Typ / JM-JP JM-JP Typ / JM-JP JM-JP JM-JP / JM-JP JM-JP / Note: (Section B) 254JM Catalog # VJMM2333T AB=9.15, AC=7.31. Catalog # VJMM2334T AB= 10.04, AC = Tap BF XO 254JM JM Shaft Dimensions AH EL EM EN EQ ES ET JP Shaft Dimensions AH EL EM EN EQ ES ET 700Typ / Typ / JM 254JM 900Typ / Typ / JM 284JM 286JM / JP / JM 326JM JP / JP 256JP 254JP 256JP 284JP 324JP NOTE: Dimension for reference only. Contact Baldor or for a detailed dimension drawing for your specific catalog number. 34
37 Dimensions Close-Coupled Pump Motors Open Drip Proof JM Mount 143JM - 326JM C SLINGER NAMEPLATE BB EQ AH ( ) ET ES Key XO AB 45 P 45 Thermal (When Req'd) EL EM U EN Tap AK BD O D 15 4 Holes Tap-BF AJ Dia. BC H Hole 2F B BA AA Lead Hole E AC A E 143JM 145JM 182JM 184JM 213JM 215JM 254JM 256JM 284JM 286JM 324JM 326JM A B D E 2F H Key O P U AA AB AC AH AJ AK BB BD BF Tap BA 143JM 145JM 182JM 184JM 213JM 215JM 254JM 256JM 284JM 286JM 324JM 326JM EL EM EN EQ ES ET x x x x x x NOTE: Dimension for reference only. Contact Baldor or for a detailed dimension drawing for your specific catalog number. 35
38 Dimensions Close-Coupled Pump Motors Open Drip-Proof JP Mount 213JP - 326JP C SLINGER NAMEPLATE BB EQ AH ( ) ET ES Key XO AB 45 P 45 Thermal (When Req'd) EL EM U EN Tap AK BD O D 15 4 Holes Tap-BF AJ Dia. BC H Hole 2F B BA AA Lead Hole E AC A E A B D E 2F H Key O P U AA AB AC AH AJ AK BB BD BF 213JP JP JP JP JP JP JP JP Tap BA EL EM EN EQ ES ET 213JP x JP x JP x JP x JP x JP x JP x JP x NOTE: Dimension for reference only. Contact Baldor or for a detailed dimension drawing for your specific catalog number. 36
39 Dimensions Washdown Duty Close-Coupled Pump 143JM through 215JM TENV Enclosure TEFC Enclosure C EQ AH ET ES BB KEY AB XO P C EQ AH ET ES BB KEY H HOLES 2F 2F B BA EM EL U BD AK EN TAP O D AA LEAD HOLE (NPT) E A E 4 HOLES TAP BF AJ DIA. H HOLES 2F 2F B BA EL EM U BD AK EN TAP A B D E 2F H KEY O P U AA AB AH AJ BF TAP AK BA BB BD XO 143JM / JM / JM / JM / JM / JM / EL EM EN EQ ES ET 143JM x JM x JM x JM x JM x JM x NOTE: Dimension for reference only. Contact Baldor or for a detailed dimension drawing for your specific catalog number. 37
40 Dimensions Close-Coupled Pump Motor Single Phase TEFC 182JM - 184JM A B D E 2F H (Dia.) Key O P U AA (Dia.) AB AC AJ (Dia. B.C.) AK BA BB BD 182JM (L) X X JM (L/LC) BF Tap XO 182JM 184JM Shaft Dimensions AH EL EM EN EQ ES ET X NOTE: Dimension for reference only. Contact Baldor or for a detailed dimension drawing for your specific catalog number. 38
41 Dimensions Close-Coupled Pump Motor Single Phase ODP 182JM - 184JM 182JP - 184JP Mechanical Seal, Type JM A B D E 2F H (Dia.) Key O P U AA (Dia.) AB AC AJ (Dia. B.C.) AK BA BB BD 182JM (L) x JM (LC) 213JM JM x (L/LC) Note: L = Single Capacitor, LC = Dual Capacitor Catalog number JML1512T has the following dimensions: AA = 1.06, AB = 8.64, AC = 7.28, XO = 2.39 BF Tap XO 182JM 184JM Shaft Dimensions AH EL EM EN EQ ES ET X Packed Pump, Type JP A B D E 2F 182JP H (Dia.) 213JM x JM Key O P U AA (Dia.) AB AC AJ (Dia. B.C.) AK BA BB BD 2.18 (L) x JP (LC) 213JP x (L/LC) 215JP 7.00 Note: L = Single Capacitor, LC = Dual Capacitor Catalog number JP L1512T has the following dimensions: AA = 1.06, AB = 8.64, AC = 7.28, XO = 2.39 BF Tap XO 182JP 184JP 213JP 215JP Shaft Dimensions AH EL EM EN EQ ES ET X X NOTE: Dimension for reference only. Contact Baldor or for a detailed dimension drawing for your specific catalog number. 39
42 Dimensions Close-Coupled Pump Motor Single Phase ODP West Coast Fit 182TCZ - 215TCZ A B D E 2F H (Dia.) Key O P U AA (Dia.) AB AC AJ (Dia. B.C.) AK BA BB BD 182TCZ (L) x TCZ (LC) 213TCZ TCZ x (L/LC) Note: L = Single Capacitor, LC = Dual Capacitor BF Tap XO 182TCZ 184TCZ 213TCZ 215TCZ Shaft Dimensions AH EL EM EN EQ ES ET x x NOTE: Dimension for reference only. Contact Baldor or for a detailed dimension drawing for your specific catalog number. 40
43 Dimensions Jet Pump Motors Single Phase ODP with Drip Cover 56J & 56C 56J, Foot Mounted A B D E 2F BA O P BD XO CJL1205A CJL1301A CJL1303A CJL1304A CJL1306A CJL1307A CJL1309A CJL1313A CJL1317A J, Footless P BD XO JL1205A JL1301A JL1303A JL1304A JL1306A JL1307A JL1309A JL1313A JL1317A C, Footless P BD XO VL1205A VL1301A VL1303A VL1304A VL1306A VL1307A VL1309A VL1318A VL1313A VL1317A VL1323A C Shaft Dimensions NOTE: Dimension for reference only. Contact Baldor or for a detailed dimension drawing for your specific catalog number. 41
44 Dimensions Jet Pump Motor Single Phase TEFC 56J 56C, Foot Mounted Note: XO = 1.56 on type 34L motors with a single capacitor. XO = 2.31 on type 34LC with dual capacitors. 56C, Footless 56J P AB AC BD XO 1.56 (L) Type (LC) 56J Type (L / LC) Note: L = Single Capacitor, LC = Dual Capacitor 42 NOTE: Dimension for reference only. Contact Baldor or for a detailed dimension drawing for your specific catalog number.
45 Dimensions Jet Pump Motor Three Phase ODP with Drip Cover 56J Stainless Steel Threaded Shaft, Foot Mounted 56J A B E O P AB AC BD Type J Type Stainless Steel Threaded Shaft, Footless 56J A B E O P AB AC BD Type J Type NOTE: Dimension for reference only. Contact Baldor or for a detailed dimension drawing for your specific catalog number. 43
46 Dimensions Jet Pump Motor Three Phase TEFC 56J 56J, Foot Mounted 56J, Footless 56J P AB AC BD Type J Type NOTE: Dimension for reference only. Contact Baldor or for a detailed dimension drawing for your specific catalog number.
47 Dimensions Single Phase Square Flange Pump Motor Open Drip Proof 56Y & 56YZ Catalog Number P BD XO JSL325A 56Y JSL425A 56Y JSL525A 56Y JSL625A 56YZ JSL725A 56YZ Three Phase - 56YZ NOTE: Dimension for reference only. Contact Baldor or for a detailed dimension drawing for your specific catalog number. 45
48 Dimensions Hydraulic Pump Mount Motor Three Phase TEFC 184TYZ Hydraulic Pump Mount Motor Three Phase TEFC 215TYZ 46 NOTE: Dimension for reference only. Contact Baldor or for a detailed dimension drawing for your specific catalog number.
49 Dimensions P-Base Vertical Solid Shaft Pump Motors Cast Iron Construction TEFC 182HP - 365HP (Normal Thrust) 182LP - 324LP (Medium Thrust) 326VP - 365VP (High Thrust) 182HP 184HP 213HP 215HP 254HP 256HP 284HP 286HP 324HP 326HP 364HP 365HP Key P U V Min AA NPT AB AC AH AJ AK BB BD BE Normal Thrust Tap BF EU 182LP 184LP 213LP 215LP 254LP 256LP 284LP 286LP 324LP 326LP 324VP 326VP 364VP 365VP Key P R* S* U NOTES: * Please refer to Keyway Detail at the end of the AC section. Drawings shown are for reference only. Dimension for reference only. Contact Baldor or for a detailed dimension drawing for your specific catalog number. V Min AA AB AC AH AJ AK BB BD BE Tap BF EU Medium Thrust 1.00 NPT NPT NPT NPT NPT High Thrust 2.00 NPT NPT
50 Dimensions P-Base Vertical Solid Shaft Pump Motors Cast Iron Construction ODP 182HP HP (Normal Thrust) 182HP 184HP 213HP 215HP 254HP 256HP 284HP 286HP 324HP 326HP Key P U V Min AA NPT AB AC AH AJ AK BB BD BE.25 x x x X X Note: (Catalog # VHM2534T has the following dimensions: P = 13.91, AB = 10.02, AC = 8.28 Dimension for reference only. Contact Baldor or for a detailed dimension drawing for your specific catalog number. Tap BF EU 48
51 Dimensions Jet Pump Explosion-Proof Motors 56J Close-Coupled Pump Explosion-Proof Motors 143JM-215JM Rolled Steel Construction A B D E 2F H O P U AA AB AC AJ AK BA BB BD Tap (400Type) (5.61) (6.53) (5.00) (5.91) 56J / JM JM / JM JM / JM JM /2-13 AH EL EM EN EQ ES ET 143JM 145JM JM 184JM JM 215JM NOTE: Dimension for reference only. Contact Baldor or for a detailed dimension drawing for your specific catalog number. 49
52 Dimensions Close Coupled Pump Drill Rig Duty 182JP Close Coupled Pump Drill Rig Duty One Size Smaller Flange & Shaft 184JP Mounting NOTE: Dimension for reference only. Contact Baldor or for a detailed dimension drawing for your specific catalog number. 50
53 Dimensions Submersible 140TY 320TY s MINIMUM SUBMERGED DEPTH MINIMUM SUBMERGED DEPTH Dimensions are in inches C L P T U V W AG AH AJ AK AL 140TY TY TY TY TY BD BE BF XR X Lead Connection B.E. Keyway BB Y XD A B Length Weight 140TY / / TY / / TY / / TY / / TY / NOTE: Dimension for reference only. Contact Baldor or for a detailed dimension drawing for your specific catalog number. 51
54 Dimensions Submersible 180TY-320TY s One Size Smaller Flange & Shaft MINIMUM SUBMERGED DEPTH MINIMUM SUBMERGED DEPTH Dimensions are in inches C L P T U V W AG AH AJ AK AL 180TY TY TY TY BD BE BF XR X Lead Connection B.E. Keyway BB Y XD A B Length Weight 180TY / / TY / / TY / / TY / NOTE: Dimension for reference only. Contact Baldor or for a detailed dimension drawing for your specific catalog number. 52
55 Dimensions Submersible 360TY-L360TY s MINIMUM SUBMERGED DEPTH Dimensions are in inches C L P T U V W AG AH AJ AK AL 180TY TY BB BD BE BF XT Lead Connection B.E. Keyway X Y XD SQ. LGTH 180TY / TY / NOTE: Dimension for reference only. Contact Baldor or for a detailed dimension drawing for your specific catalog number. 53
56 Connection Diagrams
57 Connection Diagrams
58 Connection Diagrams CD0001 CD0005 and CD0006, and
59 Connection Diagrams CD0008 CD0017A02 CD0180 and
60 Connection Diagrams CD0016A01 CD0017A01 CD0052 CD
61 Connection Diagrams CD0094 CD0098A02 CD0203 CD0225 CD0307 CD
62 Connection Diagrams CD0449 CD0661 CD0703 CD
63 UL AND CSA EXPLOSION-PROOF CLASSIFICATIONS Motors misapplied in hazardous environments can cause a fire or explosion resulting in destruction of property, serious CAUTION! injury or death. Only the end user or a qualified underwriter is to identify and select the proper class, group, division, and temperature code motor to meet the requirements of each installation. Baldor personnel can advise what listings and approvals Baldor motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments. 1. Hazardous Locations For details on area classification and equipment suitability please consult NFPA70 National Electric Code Articles Class I Group C locations are those which contain flammable gas, vapor, combustible liquid produced vapor mixed with air that may burn or explode, either having a maximum experimental safe gap (MESG) value greater than 0.45 mm and less than or equal to 0.75mm or a minimum igniting current ratio (MIC ratio) greater than 0.40 and less than or equal to Ethylene is a typical Group C gas. For other substances in this group, please consult NFPA 497. Class I Group D locations are those which contain flammable gas, vapor, combustible liquid produced vapor mixed with air that may burn or explode, either having a (MESG) value greater than 0.75 mm or a (MIC ratio) greater than Propane is a typical Group D gas. For other substances in this group, please consult NFPA 497. Class II Group E locations with atmospheres containing combustible metal dusts such as aluminum, magnesium and their alloys or other combustible dusts with particle sizes and conductivity that present similar hazards. For other substances and guidance relative to this group, please consult NFPA 499. Class II Group F locations with atmospheres containing combustible carbonaceous dusts with more than 8% entrapped volatiles. Coal, carbon black, charcoal and coke dust are examples from this group. For other substances and guidance relative to this group, please consult NFPA 499. Class II Group G locations with atmospheres containing combustible dusts not included in Group E or F, including flour, grain, wood, plastic and chemicals. For other substances and guidance relative to this group, please consult NFPA Class II Temperature Codes are typically the lower of either the ignition temperature of the combustible dust that is present or 165 C. These low surface temperature requirements (higher temperature codes) required in Class II F&G require that over temperature protection be used. Explosion-Proof Motors rated 1 1/2 HP or less have internally mounted automatic thermal overloads when indicated by suffix A. Caution must be observed when applying these to machinery applications to prevent accidental injury should the thermal device automatically reset and restart the motor. Explosion-Proof Motors rated 1 HP and larger without automatic thermal overloads have thermostats in the windings. These thermostats are pilot circuit devices to be connected to the magnetic starter circuit. 3. Surface temperatures of Baldor Explosion-Proof Motors will not exceed the following UL and CSA maximums under fault conditions. The T Code identifies the maximum absolute motor surface temperature that will be developed under all conditions of operation. Division 1 considers external surface temperature and includes overloads and locked rotor conditions. Division 2 considers internal and external surface temperatures during normal operation. Maximum Motor Surface T Code Temperature ºC ºF T T T2A T2B T2C T2D T Maximum Motor Surface T Code Temperature ºC ºF T3A T3B T3C T T4A T T Stock Motors are not suitable for applications in temperatures below -25 C (-13 F). Custom motor designs available for applications in temperatures down to -60C. Contact your Baldor Sales office for further information. 5. All Explosion-Proof motors are supplied with Explosion-Proof UL and CSA approved conduit boxes as standard. 6. Baldor-Reliance AC Explosion Proof Motors, on pages 19-20, are not approved for use on adjustable speed drives, only Inverter Duty Explosion Proof motors can be used. Custom Explosion proof ratings available, contact your Baldor-Reliance Sales Representative. Explosion Proof motors in this brochure use the following symbols to designate their Division 1, Class and Group certification capabilities. These assignments are for use with this brochure. XP Class & Group Symbol ➀ ➁ ➂ ➃ ➄ Description Class I, Group D Class I, Group D, Class II, Group F & G Class I, Group D, Class II, Group E, F & G Class I, Group C & D Class I, Group C & D, Class II, Group F & G
64 Contact your nearest Baldor District Office at these World Wide locations or visit UNITED STATES ARIZoNA PHoENIX 4211 S 43RD PLACE PHOENIX, AZ PHONE: FAX: ARKANSAS CLARKSVILLE 706 WEST MAIN STREET CLARKSVILLE, AR PHONE: FAX: CALIFoRNIA LoS ANGELES 6480 FLOTILLA STREET COMMERCE, CA PHONE: FAX: HAYWARD FORBES STREET HAYWARD, CA PHONE: FAX: CoLoRADo DENVER 3855 FOREST STREET DENVER, CO PHONE: FAX: CoNNECTICUT WALLINGFoRD 65 SOUTH TURNPIKE ROAD WALLINGFORD, CT PHONE: FAX: FLoRIDA TAMPA/PUERTo RICo/ VIRGIN ISLANDS 3906 EAST 11TH AVENUE TAMPA, FL PHONE: FAX: GEoRGIA ATLANTA 62 TECHNOLOGY DRIVE ALPHARETTA, GA PHONE: FAX: ILLINoIS CHICAGo 340 REMINGTON BLVD. BOLINGBROOK, IL PHONE: FAX: INDIANA INDIANAPoLIS 5525 W. MINNESOTA STREET INDIANAPOLIS, IN PHONE: FAX: IoWA DES MoINES 1943 HULL AVENUE DES MOINES, IA PHONE: FAX: MARYLAND BALTIMoRE 7071A DORSEY RUN RD ELKRIDGE, MD PHONE: FAX: MASSACHUSETTS BoSToN 6 PULLMAN STREET WORCESTER, MA PHONE: FAX: MICHIGAN DETRoIT 5993 PROGRESS DRIVE STERLING HEIGHTS, MI PHONE: FAX: MINNESoTA MINNEAPoLIS GEORGE WEBER DR, SUITE 400 ROGERS, MN PHONE: FAX: MISSoURI ST LoUIS LAKEFRONT DRIVE EARTH CITY, MO PHONE: FAX: KANSAS CITY 9810 INDUSTRIAL BLVD. LENEXA, KS PHONE: FAX: NEW YoRK AUBURN ONE ELLIS DRIVE AUBURN, NY PHONE: FAX: NoRTH CARoLINA GREENSBoRo 1220 ROTHERWOOD ROAD GREENSBORO, NC PHONE: FAX: ohio CINCINNATI 2929 CRESCENTVILLE ROAD WEST CHESTER, OH PHONE: FAX: CLEVELAND 8929 FREEWAY DRIVE MACEDONIA, OH PHONE: FAX: oklahoma TULSA 5555 E. 71ST ST., SUITE 9100 TULSA, OK PHONE: FAX: oregon PoRTLAND SE CAPPS ROAD CLACKAMAS, OR PHONE: FAX: PENNSYLVANIA PHILADELPHIA 1035 THOMAS BUSCH MEMORIAL HIGHWAY PENNSAUKEN, NJ PHONE: FAX: PITTSBURGH 159 PROMINENCE DRIVE NEW KENSINGTON, PA PHONE: FAX: TENNESSEE MEMPHIS 4000 WINCHESTER ROAD MEMPHIS, TN PHONE: FAX: TEXAS DALLAS TH STREET SUITE 100 GRAND PRAIRIE, TX PHONE: FAX: HoUSToN W. LITTLE YORK ROAD SUITE 300 HOUSTON, TX PHONE: FAX: UTAH SALT LAKE CITY 2230 SOUTH MAIN STREET SALT LAKE CITY, UT PHONE: FAX: WISCoNSIN MILWAUKEE 1960 SOUTH CALHOUN ROAD NEW BERLIN, WI PHONE: FAX: INTERNATIoNAL SALES FoRT SMITH, AR P.O. BOX 2400 FORT SMITH, AR PHONE: FAX: CANADA EDMoNToN, ALBERTA STREET EDMONTON, ALBERTA T6E 6R8 PHONE: FAX: ToRoNTo oakville, ontario 2910 BRIGHTON ROAD OAKVILLE, ONTARIO, CANADA L6H 5S3 PHONE: FAX: MoNTREAL, QUEBEC 5155 J-ARMAND BOMBARDIER SAINT-HUBERT, QUÉBEC CANADA J3Z 1G4 PHONE: FAX: VANCoUVER, BRITISH CoLUMBIA 1538 KEBET WAY PORT COQUITLAM, BRITISH COLUMBIA V3C 5M5 PHONE FAX: WINNIPEG, MANIToBA 54 PRINCESS STREET WINNIPEG, MANITOBA R3B 1K2 PHONE: FAX: MEXICo LEoN, GUANAJUATo KM. 2.0 BLVD. AEROPUERTO LEON, GUANAJUATO, CP37545 MEXICO PHONE: FAX: Baldor Electric Company BR456 Baldor Electric Company P.O. Box 2400 Fort Smith, AR U.S.A. Ph (479) Fax (479) International Fax (479) Printed in U.S.A. 2/14 LITHO 20,000
The Energy Independence and Security Act of 2007. The law s requirements for 1 to 500 horsepower AC motors Effective December 19, 2010
The Energy Independence and Security Act of 2007 The law s requirements for 1 to 500 horsepower AC motors Effective December 19, 2010 January 23, 2009 To Our Customers, Baldor Electric Company 5711 R.S.
We will discuss common industrial applications with guides for the proper use of electric motors on these.
INTRODUCTION: Baldor Electric Company has prepared this Specifiers Guide to help you cover all the bases when you are specifying electric motors. It will cover in a generic way most of the subjects which
Motor Accessories. C-Face Kits for Field Conversion NEMA AC Motors
C-Face Kits for Field Conversion NEMA AC s Features: Complete kits with all hardware necessary for converting Baldor 56 though 449T frame ridgid base motors to C-Face mounting with base. For Baldor conversion,
Baldor Electric Company Premium Efficiency Motor Specification Totally Enclosed Fan Cooled Motor 1-250 HP Rev June 6, 2001
Table of Contents 1.0 Purpose 2.0 Scope Baldor Electric Company Premium Efficiency Motor Specification Totally Enclosed Fan Cooled Motor 1-250 HP Rev June 6, 2001 3.0 Motor Requirements 3.1 Applicable
Baldor Explosion Proof AC and DC Motors
Baldor Explosion Proof AC and DC Motors Why Baldor? For nearly 100 years, Baldor has strived to provide customers with the best value and reliability in industrial electric motors. That dedication shows
Product Brochure. Certified Mining Motors
Product Brochure Certified Mining Motors Profile Baldor Electric Company (a member of the ABB group) is a world leader in motors for the mining industry. In the continuous (24/7) operation of underground
Baldor Electric Position on DOE Small Motor Rule
Baldor Electric Position on DOE Small Motor Rule WP0035 WP0034 Page 1 of 6 US Integral DOE Small HP Motor Rule Rule Baldor Electric Position on DOE Small Motor Rule 10/28/14 On March 9, 2010 the US Department
Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com
Model 62A MODEL 41A MODEL 44A AURORA 40A/60A Series SINGLE STAGE END PUMPS www.aurorapump.com SINGLE STAGE END PUMPS AURORA 40A/60A Series Single Stage End Suction Pumps Capacities to 4500 G.P.M. (1022
TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP
TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:
Baldor Electric Company Premium Efficiency Motor Specification Open Drip-Proof Motors 1-500 HP Rev June 6, 2001
Table of Contents 1.0 Purpose 2.0 Scope Baldor Electric Company Premium Efficiency Motor Specification Open Drip-Proof Motors 1-500 HP Rev June 6, 2001 3.0 Motor Requirements 3.1 Applicable Codes and Regulations
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS Frames 143T - 449TZ 5100 North IH 35 Round Rock, Texas 78681 Phone: 800-451-8798 512-255-4141 Fax: 512-244-5512 RECEIVING 1. Check
AC METRIC (IEC) MOTORS THREE PHASE
AC METRIC MOTORS These high efficiency motors meet North American performance standards and EPACT energy efficiency mandates, and have.5 service factors. Typically used for replacement on machine tools,
AC Electric Motors best practice
If you want to learn more about best practice machinery maintenance, or world class mechanical equipment maintenance and installation practices, follow the link to our Online Store and see the Training
General Information. ME-business can be accessed through: www. marathonelectric.com.
MARATHON ELECTRIC Since 1913, Marathon Electric s name has been recognized for engineering excellence, custom-designed products and an extensive product line of industrial quality motors. Available in
300 Series PA Pump and Cooler Assemblies
Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate
What Do All Those Things on an AC Motor Nameplate Mean?
What Do All Those Things on an AC Motor Nameplate Mean? Introduction: Ever order a motor on power, speed, and enclosure? PO says maybe "5 hp, 1,800 rpm, TEFC." New-motor nameplate says "HP 5, RPM 1748,
Baldor Electric ProSPEC MASTERFORMAT SPECIFICATION May 3, 2005. A. This specification covers integral horsepower squirrel cage AC induction motors.
SECTION 16221 - TEFC AC INDUCTION MOTORS PART 1 - GENERAL 1.1 SUMMARY A. This specification covers integral horsepower squirrel cage AC induction motors. B. This specification is intended to specify superior
A Proven Approach to Reducing Electricity Costs
A Proven Approach to Reducing Electricity Costs The Answer for an Energy Driven Economy First in Energy Efficiency Since 1920 The history of energy efficiency in industrial motors is really the story of
Multistage high-pressure multistage centrifugal pumps
Series description Wilo-Helix V 2 4 6 8 Wilo-Helix V 19-27 7 6 6 Hz - North America 22 2 18 5 16 14 4 12 3 1 V 1 V 19 V 27 8 2 6 1 5 1 15 2 25 3 4 2 35Q[US gpm] H[ft] H[m] Design Vertical multi-stage,
Axial and Mixed Flow Pumps for Large Volume Pumping
Vertical Industrial and Process Axial and Mixed Flow for Large Volume Pumping Encased (Can ) Water and Process Liquid Vertical Turbine for Water Supply from Drilled Wells Vertical close coupled single
Explosion-Proof Electric Unit Heaters
Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,
Fundamentals of Inverter Fed Motors
Fundamentals of Inverter Fed Motors Technical Manual 10/02 MN780 Contents Page The Growing Use Of Inverters.................................................................. 1 How Inverters Affect Motors....................................................................
BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.
SUBMERSIBLE PUMP selection A submersible pump consists of the following basic elements: < Bowl Assembly < Motor < Cable < Drop Pipe < Surface Plate (with)(without) discharge elbow DATA REQUIRED FOR SELECTION
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
DC MOTORS NEMA FRAME SCR RATED
NEMA FRAME SCR RATED NEMA FRAME MOTORS SCR RATED High voltage permanent magnet DC motors are typically used with an SCR (thyristor) controller in applications requiring adjustable speed and constant torque
EVANS ENTErprises, Inc.
EVANS ENTErprises, Inc. Since 1954 THE LEADER IN ELECTRO-MECHANICAL SALES, SERVICE AND INTERGRATION Our Mission Our purpose at Evans Enterprises is to serve customers by providing increased value of product
Motor Specifications. Nameplate
Motor Specifications Nameplate The nameplate of a motor provides important information necessary for selection and application. The following drawing illustrates the nameplate of a sample 30 horsepower
Horizontal Jet Pumps 1/3-1-1/2 HP
Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The
Specifying a Variable Frequency Drive s
Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable
CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ
GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html
Vertical Pumps for the Oil & Gas Industry
Vertical Pumps for the Oil & Gas Industry ITT API Expert ITT Commitment ITT is committed to the Oil and Gas market, which is the largest segment of our business. We have been investing in technology to
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
Motor and Drives Price Book
Motor and Drives Price Book Effective: 06-14-15 QUALITY STATEMENT TECO-Westinghouse Motor Company is committed to serving the needs of our customers BETTER THAN ANYONE ELSE by providing products and services
SINGLE PHASE MOTORS. INSTALLATION AND MAINTENANCE MANUAL March 21, 2006
SINGLE PHASE MOTORS INSTALLATION AND MAINTENANCE MANUAL March 21, 2006 Irvine, California (800) 474-0520 Indianapolis, Indiana (800) 866-7973 Hamilton, Ontario (800) 809-0330 e-mail: [email protected]
FULL PRODUCT GUIDE. performance quality service trust
FULL PRODUCT GUIDE performance quality service trust Vertical Turbine, Lineshaft & Submersible Pumps 6 & Larger Delivering Vertical Turbine Pump Reliability, Quality and Service Since 1969 Pump Type 6-30
CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html
Series description: Wilo-Drain TC 40
Series description: Wilo-Drain TC 40 H[m] Wilo-Drain TC 40 10 8 6 4 2 TC 40/8 TC 40/10 0 0 2 4 6 8 10 12 14 Q[m³/h] Design Submersible sewage pump Application Pumping heavily contaminated fluids for House/site
SJT / SJM / SJP Large Vertical Pumps
SJT / SJM / SJP Large Vertical Pumps The Heart of Your Process SJT, SJM, SJP Large Vertical Pumps Product Overview SJT Turbine Ns 1800 < 5000 nq 35 < 110 SJM Mixed Flow Ns 5800 < 8300 nq 113 < 161 SJP
Flygt 3068, 50Hz. Technical Specification
Flygt 3068, 50Hz Technical Specification Table of Contents Table of Contents B-pump...2 Product description...2 Motor rating and performance curves...4 C-pump...6 Product description...6 Motor rating
BSM MOTOR DRIVEN CENTRIFUGAL PUMPS
PRINCIPLE OF OPERATION A hydraulically and dynamically balanced impeller with raised vane sections discharges liquid as a result of the centrifugal force developed in rotation. The head developed is entirely
EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.
EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE. A Regal Brand EVERGREEN SOLUTIONS Powered by ECM Technology Upgrade/Replace PSC motors with Evergreen IM Residential/Light Commercial HVAC Systems Reduce
The conditions below apply to the curves shown on the following pages.
GENERAL INFORMATION STAINLESS STEEL, SILVERLINE, EVERGREEN & GOLDLINE SERIES PERFORMANCE CURVE CONDITIONS The conditions below apply to the curves shown on the following pages. a. The Performance curves
GE Energy. Motors Product Line
GE Energy Motors Product Line Expect More We ve manufactured motors for over 125 years. In 1879, GE founder, Thomas Edison constructed the first electric motor ever made for a 110 to 120 Volt line at Menlo
Application Information
AGENCY LISTINGS UL and CSA Marathon Electric s Fire Pump and Explosion Proof motors are UL Listed. Other motor types are UL Recognized, including models with inherent overheating protection as noted (i.e.
HORIZONTAL PUMPING SYSTEM
HORIZONTAL PUMPING SYSTEM BORETS U.S. INC. PERFORMANCE TECHNOLOGY INNOVATION Horizontal Pumping System What is HPS? HPS classification, Pumps, Stages, Impellers, Curves/Performance, Components Why use
XRI Severe Duty 143-449T Frame. IEC Globetrotter 63-225M Frame
XRI Severe Duty 143-449T Frame NEMA Premium /XRI - As a leading supplier of premium efficiency motors, we help conserve money and our environment. Marathon s designs are 100% compliant with CEE efficiency
CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100
CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL
FAIRBANKS NIJHUIS FIRE PUMPS. www.fairbanksnijhuis.com
FAIRBANKS NIJHUIS FIRE PUMPS www.fairbanksnijhuis.com FAIRBANKS NIJHUIS Long established as a leading fire pump manufacturer, Fairbanks Nijhuis offers a broad range of horizontal and vertical split case,
VERTICAL TURBINE AND PROPELLER PUMPS
VERTICAL TURBINE AND PROPELLER PUMPS INTRODUCTION Vertical Turbine and Propeller Pumps Model 7000 Series Turbine Pump Model 800 Series Axial Flow Propeller Pump Model 800 Series Mixed Flow Propeller Pump
I hope you find them useful and I would appreciate any comments or thoughts you might have for future improvements, corrections or topics.
COWERN PAPERS Baldor Electric Company 5711 R.S. Boreham Jr. Street Fort Smith, AR 72901 Phone (479) 646-4711 Fax (479) 648-5792 www.baldor.com Enclosed you will find a set of papers that I have written
BASIS RANGE TMB SERIES
BASIS RANGE SERIES magnetic driven pumps BASIS The pumps belong to Argal s BASIS range and feature, single stage, centrifugal impeller and magnetic drive. The range of pumps includes five models to deliver
OJ L 191, 23.7.2009, p. 26. OJ L 2, 7.1.2014, p. 1.
Table of Contents 1. Purpose of the guidelines and disclaimer... 2 1.1. The Regulations... 2 2. Scope... 2 3. Historic developments... 4 4. Scope and Requirements... 5 4.1. Scope... 5 4.2. Requirements...
Installation, Operation and Maintenance Instructions
Installation, Operation and Maintenance Instructions for AC Induction Motors 56-6800 Frames (NEMA) 63 280 Frames (IEC) MARATHON ELECTRIC Contact Motor Customer Service at: Phone: (75) 675-33 www.marathonelectric.com
The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,
The Company QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design, manufacturing and service needs in the field of submersible pumps. Our engineering
ZOP, ZOT SIGMA PUMPY HRANICE GEAR PUMPS 426 1.99 21.04
SIGMA UMY HRANICE GEAR UMS SIGMA UMY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +420 581 661 111, fax: +420 581 602 587 Email: [email protected], 426 1.99 21.04 Application In
Low Voltage Transformers Sealed, General Purpose, Dry Type
Low Voltage Transformers Sealed, General Purpose, Dry Type Catalog 7400CT9601R4/08 08 Class 7400 CONTENTS Description..............................................Page Introduction.................................................
IEC Three Phase AC Motors (Aluminum Frame) Installation & Operating Manual
IEC Three Phase AC Motors (Aluminum Frame) Installation & Operating Manual 7/09 MN301 Table of Contents Section 1 General Information.................................................. 1-1 Overview........................................................
V47 Series Temperature Actuated Modulating Water Valves
V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate
The Silencer. Silencer Outdoor Air Blower, The Name That Says It All. Quality Product. Call 1-800-848-3077 for more information
The Silencer The Silencer is our most popular outdoor-rated air blower for one simple reason. It s quiet! Turn on your Silencer day or night, and you won t disturb the neighbors or ruin your relaxing spa
SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS 426 2.98 12.06
SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS LV SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +420 581 661 111, fax: +420 581 602 587 Email: [email protected]
4" SUBMERSIBLE PUMPS
4" SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 50/60 HZ Multi-stage centrifugal submersible pumps for clean water in 4" wells. The 4" VSP pump series is carefully designed and manufactured for maximum resistant
Pumps SELECTION OF A PUMP
Pumps SELECTION OF A PUMP A water system needs to move the water produced from the source to its customers. In almost all cases in Minnesota, the source is at a lower elevation than the user so the water
CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.
CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc. 1 Centrifugal Pump- Definition Centrifugal Pump can be defined as a mechanical device used to transfer liquid of various types. As
UPBLAST & HOODED PROPELLER ROOF VENTILATORS
The Industrial Choice. Model D53 / B53 Model HD53 / HB53 UPBLAST & HOODED ELLER ROOF VENTILATORS Direct Drive & Belt Driven Model D53 / B53 Upblast Exhaust Fans Model HD53 / HB53 Hooded Supply & Exhaust
An SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps
An SPX Process Equipment Operation Universal II Industrial Series Rotary Positive Displacement ECP Pumps New levels of performance. Reduced operational and maintenance costs. For more than half a century,
JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.
Redi-Flo2, 2 Environmental Submersible Pumps MP1 Submittal Data QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS Technical Data Motor Type: Water-Filled, variable speed submersible Maximum Fluid
GE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping
GE Oil & Gas Texsteam * Pumps: precise chemical injection pumping 2 With a wide range of capacities and operating pressures, GE s versatile Texsteam pumps can handle challenging chemical pumping requirements
VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6
- B 1 Product Detail Engineering Data... B2 Structural Support... B6 Engineering Specifications... B9 - B 2 Engineering Data REMARK: Do not use for construction. Refer to factory certified dimensions &
Transformer oil cooler ALFA A02
A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using
COOLING TECHNOLOGY INSTITUTE
PAPER NO: CATEGORY: TP09-18 FANS COOLING TECHNOLOGY INSTITUTE RECENT DEVELOPMENTS IN MOTOR TECHNOLOGY ALLOW DIRECT DRIVE OF LOW SPEED COOLING TOWER FANS ROBBIE MCELVEEN BILL MARTIN RYAN SMITH BALDOR ELECTRIC
RPM AC Cooling Tower Inverter Duty PM Motors (FL250, FL280, FL440 and FL580)
RPM AC Cooling Tower Inverter Duty PM Motors (FL250, FL280, FL440 and FL580) (Specifically designed for operation with VS1CTD Adjustable Speed Cooling Tower Controls) Installation & Operating Manual 2/12
AC Submersible Pump Motors Installation & Operating Manual
AC Submersible Pump Motors Installation & Operating Manual 2/12 Any trademarks used in this manual are the property of their respective owners. Table of Contents Section 1 General Information... Overview...
Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages
Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages 2448LSG_P1 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
Electronic, Digital and Mechanical Vibration Switches
PT500 Electro-Mechanical Vibration Switch Introduction The PT500 is an economical solution that provides basic vibration protection for rotating reciprocating machines. The PT500 uses an inertia sensitive
SVA SIGMA PUMPY HRANICE SELF PRIMING PUMPS 426 2.98 16.05
SIGMA PUMPY HRANICE SELF PRIMING PUMPS SVA SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +40 581 661 111, fax: +40 581 60 587 Email: [email protected] 46.98 16.05 Applications
O-I DUBI PLANT FANS Quotation Spec Data & Specifications
TECHNICAL DATA O-I DUBI PLANT FANS Quotation Spec Data & Specifications 1 page for the global informations + 12 pages for the fans data Revision 2 end april Global informations: These fans are a replacement
Documenting Results to Validate Energy Savings Projects: Case Study of Direct Drive Cooling Tower Installations: Before and After
Documenting Results to Validate Energy Savings Projects: Case Study of Direct Drive Cooling Tower Installations: Before and After Roman Wajda, Baldor Electric Company ABSTRACT Documenting the actual energy
Uniquely designed and engineered specifically for the pulp and paper industry.
Universal SPU2 Series Uniquely designed and engineered specifically for the pulp and paper industry. For more than half a century, Waukesha Cherry-Burrell has been a leader in the design, manufacturing
TECHNICAL BROCHURE BAQUABII. * Available up to 100 GPM systems. Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS
TECHNICAL BROCHURE BAQUABII * Available up to 1 GPM systems Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS FEATURES The AB2 variable speed pump controller and complete booster package kits, provide
N-PUMP SERIES FOR MAXIMUM RELIABILITY AND EFFICIENCY IN WASTEWATER HANDLING. Flygt
N-PUMP SERIES FOR MAXIMUM RELIABILITY AND EFFICIENCY IN WASTEWATER HANDLING Flygt The Concept N-Pump series. Bringing NEW levels of efficiency to wastewater handling applications Reduced pumping efficiency,
APPENDIX F VIBRATION TESTING PROCEDURE
APPENDIX F VIBRATION TESTING PROCEDURE Appendix F SPS-F-1 of 14 VIBRATION PERFORMANCE TESTING I. General Perform a vibration analysis on all motor driven equipment listed below after it is installed and
Centrifugal Fans and Pumps are sized to meet the maximum
Fans and Pumps are sized to meet the maximum flow rate required by the system. System conditions frequently require reducing the flow rate. Throttling and bypass devices dampers and valves are installed
Scraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
SPP Pumps Inc. Atlanta
SPP Pumps Inc. Atlanta UL Listed, FM Approved Fire Pump Sets Horizontal Split Case Pumps Flows from 200-5000 US GPM Vertical Turbine Flows to 5000 US GPM In-Line Pumps Flows to 750 US GPM End Suction Flows
SUBM Electrical Submersible Pumps and Motors
SUBM Electrical Submersible Pumps and Motors Pleuger Water-Filled Design Byron Jackson Oil-Filled Design Experience In Motion Pump Supplier to the World Flowserve is the driving force in the global industrial
- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS
Rotary Phase Converters
FACTS from Ronk Electrical Industries, Inc. Bulletin 11981 Rotary Phase Converters ROTOVERTER Pat. No. 3,670,238 ROTO-CON Pat. No. 4,158,225 What are the ROTO-CON and ROTOVERTER power converters? The ROTO-CON
Heating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
SIGMA GROUP a. s. Divize průmyslová čerpadla
SIGMA GROUP a. s. Divize průmyslová čerpadla SIGMA GROUP a. s. INDUSTRIAL PUMP DIVISION Jana Sigmunda 79, 783 50 LUTÍN SEWAGE PUMPS NFPH, NFVH, NFJH, NFRH, NFPV, NFVV, NFJV, NFRV, NFPW NFVW Tel.: +420
UM Series UniModule. Pre-assembled, C-face Clutches and Brakes. Original Design Sizes 210 & 215. GEN 2 Design Sizes 50, 100 & 180
re-assembled, C-face Clutches and Brakes UniModules offer the ultimate in Clutch/ Brake performance and convenience. UniModules offer the same performance as EM s without the assembly required. Completely
Standard offering (pumps)
MDM PUMPS LTD Spring Lane Malvern, Worcs. England. WR14 1BP This outlines what we typically supply. Tel: +44 (0)1684 892678 Fax: +44 (0)1684 892841 E-mail: Website: Standard offering (pumps) [email protected]
POLARIS AIR COMPRESSOR SERIES. engineering. excellence. stellar. performance. A World Leader for Centrifugal Compressors
POLARIS AIR COMPRESSOR SERIES engineering excellence stellar performance P - 3 0 0 RELIABLE 100% OIL-FREE ENGINEERED AIR A World Leader for Centrifugal Compressors It s simple: The Polaris Air Compressor
ANGLgear. right angle drives Inch and Metric Series. The Original Right Angle Gear Drive Made in the U.S.A.
ANGLgear right angle drives Inch and Metric Series The Original Right Angle Gear Drive Made in the U.S.A. INDEX INTRODUCTION Intro to ANGLgear Inch & Metric Series pg. 2-3 2 Flange Units, Inch Series pg.
CORNELL PUMP COMPANY WATER TRANSFER HYDRAULIC FRACTURING EFFICIENT BY DESIGN
WATER TRANSFER HYDRAULIC FRACTURING HYDRAULIC FRACKING Setting the Standard For Fracking Cornell s pumps are designed and engineered for the most rugged and demanding installations. From the Antrim to
Flygt Ball Check Valves
4/13 Supersedes: 6/96 The basic purpose of a check valve is to permit flow in one direction, prevent flow in the opposite direction and perform this function automatically and with minimum maintenance.
ENGINEERING BULLETIN No. EB 039 Product: Cooling Towers, Closed Circuit Coolers & Evaporative Condensers Date: June 2003
For Distribution ENGINEERING BULLETIN No. EB 039 Product: Cooling Towers, Closed Circuit Coolers & Evaporative Condensers Date: June 2003 Purpose: Variable Frequency Drives The purpose of this Engineering
Power Recovery Turbines
Power Recovery Turbines Fixed and Variable Geometry Vertical Horizontal Bulletin PS-90-1 (E) Pump Supplier To The World Flowserve is the driving force in the global industrial pump marketplace. No other
SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor
INSTALLATION, OPERATION AND MAINTENANCE MANUAL For SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor Yeomans Chicago Corporation 3905 Enterprise Court P.O. Box 6620 Aurora, IL 60598-0620 Phone:
Testing Capabilities. Worldwide Designers & Manufacturers of Air Moving Equipment
Testing Capabilities Twin Twin City City Fan Fan Companies, Companies, Ltd. Ltd. Worldwide Designers & Manufacturers of Air Moving Equipment TestingCapabilities Twin City Fan Companies, Ltd. In today s