1 LAWA Public Restroom Design Guidelines and Specifications Updated Version July 7, 2008 Prepared by: Construction and Maintenance Division and Airports & Facilities Planning Division
2 TABLE OF CONTENTS CHAPTER PAGE 1. Introduction 1 2. Planning Considerations 2 3. Theme Design 7 4. Signage 8 5. Vestibule Entrances 9 6. Floors Walls Ceilings Doors/Door Hardware Toilet Compartments And Urinal Screens Countertops And Fixtures Baby Changing Stations Mechanical Requirements Plumbing Requirements Lighting Requirements Custodial Closet Fixtures and Accessories Attic Stock Revision History Synopsis Typical Plans Source List Equipment list Catalog Sheets 39
3 1. INTRODUCTION Opportunity: Los Angeles World Airports is embarking on a major public restroom renovation program. This is a milestone opportunity to provide the public with new facilities in all passenger terminals and other public areas of the airport. This opportunity will allow the creation of a unified standard so that there will be a continuity of design from terminal to terminal, consistency in conforming with ADA requirements, and the creation of more comfortable and cheerful facilities. Solution: Through the joint effort of the Construction and Maintenance Division (C&M) and Airports & Facilities Planning Division (AFPD), the following Los Angeles World Airports (LAWA) Public Restroom Design Guidelines and Specifications have been developed. The following components will be adhered to for all restroom design at LAWA: A unified material and fixture standard to reduce the cost of repair and maintenance. Aesthetic criteria guidelines. A mandatory restroom design guideline for new, addition, remodel or upgrade to any restroom facility. This standard shall cover all public area restrooms. This standard shall be reviewed annually. 1
4 2. PLANNING / CONSIDERATIONS 2.1 Design Guidelines LAWA is committed to being ahead of the curve when it comes to addressing the needs of people with disabilities and mobility issues. As part of its commitment to ensuring equal access to disabled travelers, LAWA proposes the following standards for all Vestibule entrances, door ways and ADA stall doors in order to provide access to public restrooms. ALTERATIONS TO EXISTING PUBLIC RESTROOMS: Where it is feasible to comply with clear opening widths to accommodate a 42 wide wheel chair without reducing fixture count or affecting minimum ADA regulations. NEW CONSTRUCTION OF PUBLIC RESTROOMS: Shall comply with clear opening width to accommodate a 42 wide wheel chair Toilet rooms will typically be designed as part of the core building space in new construction. The location of toilet rooms in alteration or renewal projects may be limited by building configuration or utility location, but should be located for easy access in a logical location in the facility Submittal of consultant s design shall be submitted through the project manager and forwarded to the appropriate LAWA divisions for approval. 2
5 2.1.4 LAWA approvals shall not exempt the design from complying with building, life safety, fire and ADA codes Consultant shall submit hard copies during the review process and submit CADD files complying with LAWA CADD standard for final design LAWA encourages consultants to explore new ideas, new material and techniques Consultant shall make presentation of the proposed, new material or construction techniques if they are not covered in the Public Restroom Design Guidelines and Specifications Distance and location site plan or floor plan shall be provided to show restroom service area or service radius Maximum room capacity of the lounge or waiting area shall be shown on the restroom floor plan Restroom signage, visibility, type and size shall be shown on the floor plan When consultants are responsible for design and drawings, they will be required to provide plan checked drawings and specifications In case existing restrooms need to be closed for the project, signage or escort shall be provided for directions to next closest restroom that is in service. 3
6 FAMILY RESTROOM Distance and location site plan or floor plan shall be provided to show restroom service area or service radius Toilet compartments shall provide enough space for hand carried luggage and must be equipped with a heavy-duty coat hook for backpacks (Please see Section 10.5 for further information) Every public restroom shall be equipped with a baby changing station when remodeled. TODDLER SIZE TOILET OPTIONAL AS PER LAWA REQUIREMENT When space allows, a separate single-use family restroom shall be provided. (Please see Section for further information) All material, including structure and finishes, shall be designed to resist impact, etching, graffiti, and water damage All fixtures and accessories shall be designed for easy maintenance. Damage due to vandalism and accidents are expected and occur more often than at other commercial facilities Removal of fixtures and accessories shall be fast and easy for the maintenance crew with proper tools, but shall not be easily removed by hand or with simple basic tools Space shall be provided under counters and in compartments to allow for ease of maintenance and cleaning equipment. 4
7 Finish materials and joints shall withstand the frequent friction or pressure from maintenance and cleaning and shall endure chemical erosion from custodial cleaning products Epoxy grout shall be used All horizontal surfaces shall slope to sink or floor drains The use of large size tiles is recommended to reduce area of grout joints. 5
8 2.2.0 Planning Maintenance and Upgrades Survey of existing conditions shall be made before every design project remodel or rebuild. Designer or consultant shall verify dimensions on site The CADD files of each design project will contribute to the development of an electronic facility database. The database shall include plans, elevations, locations, and inventories of fixtures, accessories, finishing material, signage, electrical and mechanical items Construction cost estimates shall be provided as budgetary (class C) during design phase and as actual (class A) before construction. Estimates shall be kept in file as a reference for future projects Cost estimates shall be a combined effort between the architect/engineer and C&M Upgrading of restrooms shall be scheduled every 5 to 8 years Coordinating the restroom upgrades concurrently with upgrades of adjacent concessions should be considered. 6
9 3. THEME DESIGN 3.1 The general style should follow the theme of each terminal or location. 3.2 The upgrade/remodel does not have to follow the existing style or color of restrooms in the same terminal/facility. Each upgrade/remodel should follow current trends and styles and use current methods and materials. 3.3 The color scheme and material texture shall follow the theme of each terminal and be acceptable to LAWA. Extreme contrast color schemes are not allowed. Lively, vibrant colors are encouraged to enhance the over all aesthetic of the terminal. 3.4 Lighting should be ample but comfortable. There should be no areas that appear dark and unlit. Special lighting may be required at baby change stations, entry vestibules, and in front of mirrors. 3.5 Certain selected vestibule entrances shall be designated for site-specific public artwork in durable materials. (See Section 5.7 for further information). EXAMPLE OF PUBLIC ART AT SAN DIEGO INTERNATIONAL AIRPORT RESTROOM VESTIBULE (ARTIST: MARY LYNN DOMINQUEZ) 7
10 4. SIGNAGE 4.1 Entranceways leading to men s sanitary facilities shall be identified by an equilateral triangle, ¼- inch thick with edges 12 inches long and a vertex pointing upward. 4.2 Entrance ways leading to women s sanitary facilities shall be identified by a circle, ¼-inch thick and 12 inches in diameter. 4.3 Unisex sanitary facilities shall be identified by a circle, ¼-inch thick 12 inches in diameter with a ¼-inch thick triangle superimposed on the circle and within the 12-inch diameter. 4.4 These geometric symbols shall be located at a height of 60 inches. 4.5 The symbols specified above shall consist of a white figure on a blue background. The blue shall be equal to Color No in the Federal Standard 595B. 4.6 Accessible stalls shall display a rectangular decal, 9 W x 3 H, white and blue sign, specifying priority for persons with disabilities. Typical location installation as shown below. Typical location of decal installation. 8
11 5. VESTIBULE ENTRANCES 5.1 Vestibules without doors shall have a clear opening of at least 48. Increase size of vestibule width in relation to size of toilet room. EXISTING VESTIBULE CONDITION AT A LAX TERMINAL 5 RESTROOM 5.2 Entrances equipped with doors at multi-fixture toilets shall have Fire Code compliant door closers or magnetic releases that are directly connected to the fire life safety system. With approval from the Fire Department, use of door closers that are equipped with local release mechanisms are acceptable. All doors shall remain opened except during maintenance operations. 5.3 Entrances featuring vestibules in lieu of hinged doors shall also be encouraged as this alternative will provide unobstructed access to passengers. EXAMPLE OF GLASS ACCENT TILE BANDS AT SEA-TAC AIRPORT S BAGGAGE CLAIM RESTROOM (TILE CREATOR: NORMANCOURTNEY) 5.4 Vestibules shall provide easy passage between the corridor and restroom while maintaining a visual barrier to protect the privacy of restroom occupants. 5.5 Floor and wall finishes shall match or be compatible with the restroom material and finishes. EXAMPLE OF PUBLIC ART AT SEA-TAC AIRPORT S MAIN TERMINAL RESTROOM VESTIBULES. (ARTIST: STEVE GARDNER) 5.6 Bumper and wall guards shall be provided in vestibule areas to reduce the amount of luggage and carts that impact and damage the walls. ADA accessibility requirements shall be considered when installing such materials. RECESSED CEILING WALL WASHERS AT RESTROOM ENTRANCES TO HIGHLIGHT PUBLIC ART 5.7 Selected vestibule entrances shall be equipped with wall washers and neutral wall finishes, for art program locations. PLAN- LAX TERMINAL 6 SOUTH-WEST WOMEN S RESTROOM 9
12 6. FLOORS 6.1 Finish floor assembly shall be ceramic tile, stone or concrete. 6.2 Floor & wall color schemes shall be coordinated. Lively, vibrant colors are encouraged to enhance the over all aesthetic of the terminal. 6.3 Finish floor assembly shall be set on a conventional Portland cement mortar installation with a waterproof membrane over the floor substrate. The waterproof membrane shall extend to the wall structure for at least 3 feet high behind all wall hung plumbing fixtures and 12 high for walls without plumbing fixtures. 6.4 When partitions or other built-in equipment penetrate waterproofing layer, the design must show the method of water seal to protect the penetration. 6.5 Floor finishes shall be durable and non-slippery. 6.6 Joints shall be less than ¼ and sealed with an approved 100% solid epoxy grout product. 6.7 Floor surfaces shall slope to the floor drain. 6.8 Floor drains shall not be located within any compartment or under any counter and shall be located as close to the center of the restroom as possible. 6.9 Care must be taken in laying out floor slopes so that code-required counter heights and clearances are maintained at all locations. 10
13 6.10 Floor drains shall be designed to fit in the space of a single tile or center to the crossing of joints Floor drains to be bronze or stainless steel to coordinate with color of flooring The opening of floor drains shall be minimized to avoid small items from being dropped in the opening Floor drains shall be self-priming Floor drains shall be removable with special tools for maintenance and repair purposes. 11
14 7. WALLS 7.1 Walls shall be constructed of galvanized steel studs of a minimum of 18-gauge thickness. 7.2 Stud spacing shall be no greater than 16 o.c. 7.3 When feasible, metal stud walls shall be set on a 6 high concrete curb. 7.4 All restroom walls shall be constructed using conventional cement mortar installation from floor to ceiling. 7.5 Lath shall be 3.4 metal lath galvanized. 7.6 Lath shall be installed over a waterproof membrane, and the waterproof membrane shall be installed over ½ water-resistant marine grade fire-resistive plywood. 7.7 Sound insulation is required in walls. 7.8 Wall finish assembly shall be ceramic tile or stone (exception may be glass mosaic tiles or other approved accent finishes). 7.9 Wall finish joints shall be no larger than 1/8. Only 100% solid epoxy shall be used to seal joints Wall finish shall be no less than 6 x 6 (exception may be glass mosaic tiles or other approved accent finishes) Wall finish assembly shall be full height (no wainscoting). 12
15 7.12 Wall base shall be one-piece cove tile to avoid water or small debris trapped at wall-floor joint Wall floor assembly shall be set on a conventional Portland cement mortar installation with a waterproof membrane over the substrate When partitions or other built-in equipment penetrate waterproofing layer, the design must show the method of water seal to protect the penetration Stainless Steel corner guards shall be provided at all outside corners. The top of the corner guard shall be no less than 42 above finish floor (AFF). Corner guard shall be installed above the base tile Backing shall be provided on all walls for dispensers, receptacles, partitions, countertops, and fixtures. 13
16 8. CEILINGS 8.1 Ceiling assembly shall be designed as required for structural safety. Suspended ceiling systems are not acceptable. 8.2 Ceiling finishes shall be of a smooth surface. Cement plaster with a paint finish. Water-resistant drywall is acceptable. Porous material is not acceptable. Other water-resistant material is acceptable if approved by the project manager and C&M. 8.3 Ceiling heights shall be 9 feet minimum, except in stall compartment areas where the soffit shall be 8 feet. Structural beams shall be installed for anchoring of ceiling-hung partitions. 8.4 Access for water shut-off valves, temperature control valves, electrical transformers, etc. shall be located in ceiling access panels to the extent possible. 14
17 9 DOORS / DOOR HARDWARE 9.1 Door size shall provide a minimum clear width opening for a 42 wide wheelchair. (Please see section for further information). 9.2 All door hardware and locks shall be in compliance with the door and lock specifications set forth by LAWA C&M. 9.3 Locks shall be provided with interchangeable core. 9.4 Deadbolts shall meet the requirements of all applicable fire codes. 9.5 No doorstops are allowed. 9.6 Door hardware shall be stainless steel. 9.7 Doors shall be equipped with push plate and pull bar with text or signs indicating direction of door swing. 9.8 Door jambs shall be in compliance with the door and lock specification set forth by LAWA C&M. 15
18 10. TOILET COMPARTMENTS AND URINAL SCREENS 10.1 Toilet compartment partitions shall be patterned Stainless Steel or solid surface Sierra Series manufactured by Bobrick or approved equal Toilet compartment partitions shall be ceilinghung with a floor-supported pilaster at every third stall. Partition pilasters supporting adjacent partitions with accessible grab bars shall extend to the floor and be equipped with a stainless steel shoe. Floor-to-ceiling pilasters shall be located at all corners of toilet stall partition that are not supported by an adjacent wall Architect to provide toilet partitions plans that provide a solid anchorage of the partition system based on the number of stalls, ceiling heights, partition construction, material, and hardware Locked partition doors shall be removable by lifting the door up and off the hinges with special tools. Doors at unoccupied stalls shall be held partially open (approximately 30 degrees) in a consistent and uniform position and shall open into the stall, except at accessible stalls, where the doors shall swing out Coat hooks shall be installed inside of each compartment wall at centerline and 6 inches below top of door except at accessible stalls where the maximum is 48 above finished floor. Coat hooks shall bear at least 15 lbs (See Diagram A). DIAGRAM A 16
19 10.6 Clearance between toilet partitions/panels and wall surfaces, panels, or pilasters shall be limited to a tolerance of ¼ ¾ Cantilevered fin-style screens are required between urinals and shall be fabricated of the same material as the compartments. Screens shall have a radius top edge to avoid placement of items on the edge of the screen. Urinal screens should be provided to match toilet partitions Toilet partitions and urinal screens are required to be fastened to the walls and other panels using continuous brackets. The brackets must equal the height of the partitions and urinal screens ADA toilet stall doors shall provide a clear width opening for a 42 wide wheelchair. (Please see Section for further information). 17
20 11. COUNTERTOPS AND FIXTURES 11.1 All countertops, lavatories and fixtures shall meet ADA accessibility codes Public restrooms shall use countertops that are self-draining, monolithic, retain water, and have a 4-inch high approved solid surfacing material back splash against adjacent walls, and a 4-inch skirt at the front. All edges and corners shall be rounded for safety. Self draining component shall be ¼ per foot Height of counters shall be mounted at 34-inches above finished floor. Counters are to be supported by a tiled fin wall at each end or provided with other structurally engineered solution to support the weight of the counter Lavatories are to be integral and placed no more than four inches from the back splash so that soap discharge will fall into the lavatory rather than onto the counter Soap dispensers shall be mounted at 45-degrees to the right of the bowl center line on self-draining counter tops, allowing soap drips to fall into the bowls On self-draining countertops, faucets shall be mounted at 45-degrees from the centerlines on the left of the soap dispenser Lavatory overflow drain holes shall be at the front of the bowl, out of view and must be integral to bowl. 18
21 12. BABY CHANGING STATIONS 12.1 All public restrooms are to be equipped with baby changing stations Fixed-type baby changers constructed of stainless steel or a solid surface material are preferred because they are maintenance free. This type should be used whenever there is sufficient space in the restroom Prefabricated baby changers which fold out of the wall, such as Koala Bear, may be used when there is not sufficient space for the type described above The prefabricated baby changers should be the type with stainless steel door and flange. 19
22 13. MECHANICAL REQUIREMENTS 13.1 Exhaust system shall have a minimum of 15 air changes per hour Supply air system shall have a minimum of 6 air changes per hour Supply air system remaining air shall come from transfer Exhaust fan type shall be mushroom type manufactured by Cook CFM for exhaust shall be determined by room volume x 15/60. 20
23 14. PLUMBING REQUIREMENTS 14.1 At least one floor drain shall be installed in each restroom, more if layout dictates Flush-mounted hose bibb, with stainless steel cover, should be located under sink for custodial use 18 above the finish floor provide key stops Only approved integrated drains and tailpieces shall be used Only approved three-piece, main, branch, riser and drain valves full port with stainless steel ball and stem shall be used Toilets and urinals shall be mounted to walls and controlled with automatic flushing sensors Sinks will have automatic on/off sensors There is to be a cleanout at each urinal. 21
24 15. LIGHTING REQUIREMENTS 15.1 General illumination lighting in passenger terminal public restrooms may be provided by compact fluorescent downlights Supplemental lighting in passenger terminal public restrooms may be provided by wall washers or cove lights at the back of the toilet compartments, above the urinals, and above the wash basins. Wall washers or cove lighting provides functioning task lighting while making the walls brighter, thereby providing a more inviting environment The emergency fixture is to be located above the wash basins. 22
25 16. CUSTODIAL CLOSETS FIXTURES AND ACCESSORIES 16.1 Custodial closets are to have a smooth surface or concrete floors, floor drains, and floormounted mop service sinks Room to be for exclusive use by custodial staff. No utilities or other functions are allowed in closets Door is to swing out into hall or room Provide adequate ventilation Refer to Section 7 for wall requirements. 17. ATTIC STOCK 17.1 Owner is to be provided with 10% allowance for attic stock REVISION HISTORY SYNOPSIS 18.1 The revision history synopsis shall be developed as the LAWA Public Restroom Design Guidelines and Specifications program develops through the years. It will be developed to allow for accurate tracking of historical data pertaining to the development of the restroom facilities. 23
26 19. TYPICAL PLANS This Optimal floor plan allows the closure of portions of the restroom for custodial as well as long term maintenance purposes while leaving the other portion of the restroom fully operational. Portions of this Optimal restroom will always be open, thereby providing a higher level of service for LAX passengers. Such restrooms may be implemented on a space-available basis. 24
27 Various floor plans have been developed to illustrate potential design solutions for restrooms of various configurations. 26
28 This reflected ceiling plan shows the use of fluorescent wall washer lighting fixtures on the ceiling above the wash basins and behind the toilets, and energy saving compact fluorescent downlights in the center of the room. All lighting fixtures shall be recessed. They may be surface mounted if existing conditions dictate. 27
29 Various floor plans have been developed to illustrate potential design solutions for restrooms of various configurations. 28
30 This Optimal reflected ceiling plan shows the use of fluorescent wall washer lighting fixtures on the ceiling above the wash basins and behind the toilets, and energy saving compact fluorescent downlights in the center of the room. All lighting fixtures shall be recessed. They may be surface mounted if existing conditions dictate. 29
31 20. SOURCE LIST BOBRICK accessories, partitions and urinal screens. Thomas Partitions & Specs 4031 Verdugo Rd, Los Angeles, CA ELECTRICAL FIXTURES One Source Distributors Outside Sales-Holly Feinstein S. Woodruff Ave. Downey, CA Main (562) Fax (562) Associated of Los Angeles Outside Sales-Victor Chiovare 2585 E. Olympic Blvd. P.O. Box Los Angeles, CA Main: (323) Fax: (323) HVAC Johnstone Supply Inglewood Ave. Hawthorne, CA (310) Toro Aire 1708 Mahalo Place Dominguez Hills, CA (310) PLUMBING FIXTURES Fergunson Enterprises 2218 Broadway Santa Monica, CA (310) Ferguson s 8532 Melrose Ave West Hollywood p: f: Plumbing and Industrial Fixture Supply East Philadelphia Whittier, CA (562) Smardan Supply Halldale Ave. Gardena, CA (310)
32 SOURCE LIST CERAMIC TILE SELF DRAINING COUNTERTOPS and BABY CHANGING STATION (Solid Surface) STAINLESS STEEL BABY CHANGING STATION Longust 1180 N Anaheim Blvd Anaheim, CA Toll-Free: ext.348 Fax: (714) GW Surfaces 2432 Palma Drive Ventura, Ca (fax) Aul Pipe & Tubing Incorporated 2701 S Bonnie Beach Pl, Los Angeles (323)
33 21. EQUIPMENT LIST RESTROOM ACCESSORIES Recessed Waste Receptacle Bobrick B-3644 Classic Series Recessed Waste Receptacle (No Paper Towel Dispenser) None Semi Recessed Waste Receptacle Bradley Series Semi Recessed Waste Receptacle (No Paper Towel Dispenser) LAWA Approved Restroom Receptacle Waste Receptacle Large Capacity (Stand Alone) Bobrick B-2280 Floor-Standing Open Top Waste Receptacle LAWA Approved Restroom Receptacle Sanitary Napkin Receptacle Bobrick B-270 Contura Series Waste Receptacle Surface Mounted None Hands Free Paper Towel Dispenser Georgia Pacific enmotion Hands Free Stainless Steel None Hand Dryer Dyson A02 Dyson Airblade A02 None Seat Cover Dispenser Bobrick B-4221 Contura Series Seat- Cover Dispenser Surface Mounted Bobrick - B
34 RESTROOM ACCESSORIES Soap Dispenser Bobrick B-830 Sureflo Soap Dispensing System None Toilet Tissue Dispenser Bobrick B-2892 Stainless Steel Twin- Jumbo Roll Toilet Tissue Dispenser None Sanitary Napkin Vendor Bobrick B Classic Series Recessed Sanitary Napkin/Tampon Vendor Bobrick TrimLine B Grab Bar (straight) Bobrick B-6806 x 36 Straight Bar None Grab Bar (corner) Bobrick B Corner 36 x 54 None Baby Changing Station (stand alone) Baby Changing Station (Recessed Mounted) Aul-Tube & Steel See Resource List LAWAABCS Stainless Steel Custom Baby Changing Station Koala Bear Kare KB110SSRE Baby Changing Station Stainless Steel Recessed-Mounted Substitute Material Corian None 33
35 RESTROOM/PLUMBING ACCESSORIES Mirrors Bobrick B-290 Glass Mirror With Stainless Steel Angle LAWA Substitute Frame Floor Drains JR Smith 2005Y (B) Floor Drain Square Top As needed. Floor/Wall Clean Out Clean-out plugs to be of As needed ABS material Hose Bibb JR Smith 5509QT As needed Trap Primer Precision Plumbing Products As needed As needed Water Shock Arresters Precision Plumbing Products SC-500A-SC- 2000F As needed Mixing Valves Symmons As needed Angle Stops Brass Craft Iron Pipe As needed Lavatory Sink Supply Risers Stainless Steel As needed 34
36 PLUMBING FIXTURES Service Sink Faucet Chicago 305-VB-R As needed Strainer Chicago 327ACP As needed Auto Faucet (Lavatory) Chicago Hytronic Traditional None. Auto Flusher (Toilet and Urinals) Sloan 111ESS (Toilet) 186-1ESS (Urinal) 111ESS (Toilet) 186-1ESS (Urinal) None. Toilet American Standard Afwall White Wall Hung None. Water Closet Seat Olsonite 95C Elongated, Open Front, White As needed 35
37 PLUMBING FIXTURES Service Sink Commercial Enameling 871 As needed Urinal American Standard Allbrook White None. 36
38 COMPARTMENTS/COUNTERS Toilet Compartments Bobrick 1090 Series Sierra Series Water & Fire Resistant Solid Color Reinforced Composite Toilet Partitions & Urinal Screens Solid Phenolic Partition (Bobrick). Urinal Screen Bobrick 1090 Series Sierra Series Water & Fire Resistant Solid Color Reinforced Composite Toilet Partitions & Urinal Screens Solid Phenolic Partition (Bobrick). Stainless steel partitions with diamond pattern. Self Draining Counter Tops Corian Self-Draining Self-Draining Counter Top with integral sink. 4 back splash 4 no drip front skirt None. Sahara (f) CERAMIC TILE Toilet wall tile Toilet Floor tile MISCELLANEOUS Automatic Air Freshner Crossville (or approved equal) Crossville (or approved equal) 12 x12 Polished 12 x 12 Unpolished Technical Concepts Model# Automatic Air Freshner None. LAWA approved alternate. LAWA approved alternate. 37
39 LIGHTING/ELECTRICAL Compact Fluorescent Frame-In-Kit Lightolier 1002F1 Lytecaster Recessed Downlighting LAWA approved alternate. Recessed Down Light Reflector Trim Lightolier 1045 Lytecaster Recessed Downlighting Reflector Trim LAWA approved alternate. 6 Compact Fluorescent Downlight LSI Lightron, Inc. Series 206CFLH Recessed downlighting. LAWA approved alternate. Linear Wall Mounted 6 x6 Fluorescent LSI Lightron, Inc. Series 99W Continuous wall mounted lighting fluorescent fixture. LAWA approved alternate. Fluorescent Perimeter Lighting LSI Lightron, Inc. Series 900 Continuous ceiling mounted fluorescent lighting fixture. LAWA approved alternate. Fluorescent Perimeter Lighting Prudential Lighting P-60-2T8-04-NS- TMW-D2 Continuous surface fluorescent lighting fixture. LAWA approved alternate. Fluorescent Perimeter Lighting Prudential Lighting IT8-04 (08 )-BLA- SC-X4B-B Continuous recessed ceiling mounted fluorescent lighting fixture (also for wall washer application). LAWA approved alternate. 38
40 22. CATALOG SHEETS RESTROOM ACCESSORIES Recessed Waste Receptacle Bobrick B-3644 Classic Series Recessed Waste Receptacle (No Paper Towel dispenser) None BOBRICK B
41 RESTROOM ACCESSORIES COMPONET MANUFACTURER MODEL DESCRIPTION ALTERNATE Semi Recessed Waste Receptacle Bradley Series Semi Recessed Waste Receptacle LAWA Approved Restroom Receptacle BRADLEY
42 RESTROOM ACCESSORIES Waste Receptacle Large Capacity (stand alone) Bobrick B-2280 Floor-Standing Open-Top Waste Receptacle LAWA Approved Restroom Receptacle BOBRICK B
43 RESTROOM ACCESSORIES Sanitary Napkin Receptacle Bobrick B-270 Contura Series Waste Receptacle Surface Mounted None BOBRICK B
44 RESTROOM ACCESSORIES Hands Free Towel Dispenser Georgia Pacific enmotion Hands Free Stainless Steel None GEORGIA PACIFIC
45 RESTROOM ACCESSORIES Hand Dryer Dyson A02 Dyson Airblade A02 None Dyson A02 44
46 RESTROOM ACCESSORIES Seat Cover Dispenser Bobrick B-4221 Contura Series Seat- Cover Dispenser Surface Mounted Bobrick - B-221 BOBRICK B-4221 BOBRICK B
47 RESTROOM ACCESSORIES Soap Dispenser Bobrick B-830 Sureflo Soap Dispensing System None BOBRICK B
48 RESTROOM ACCESSORIES Toilet Tissue Dispenser Bobrick B-2892 Stainless Steel Twin- Jumbo Roll Toilet Tissue Dispenser None BOBRICK B
49 RESTROOM ACCESSORIES Sanitary Napkin Vendor Bobrick B Classic Series Sanitary Napkin/Tampon Vendor TrimLine B-3500 BOBRICK B BOBRICK B (ALTERNATE) 48
50 RESTROOM ACCESSORIES Grab Bar (straight) Bobrick B-6806 x 36 Straight Bar None BOBRICK B-6806x36 (6806x42) 49
51 RESTROOM ACCESSORIES Grab Bar (corner) Bobrick B Corner 36 x 54 None BOBRICK B
52 RESTROOM ACCESSORIES Baby Changing Station (recessed mounted) Koala Bear Kare KB110SSRE Stainless Steel Baby Changing Station Recessed Mounted None KOALA BEAR KARE KB110SSRE (GREY) 51
53 RESTROOM ACCESSORIES Mirrors Bobrick B-290 Glass Mirror With Stainless Steel Angle Frame LAWA Substitute BOBRICK B-290 (OR LAWA SUBSTITUTE) 52
54 PLUMBING FIXTURES Floor Drains JR Smith 2005Y (B) Floor Drain Square Top As needed. JR SMITH FLOOR DRAIN 2005Y (B) OVERFLOW FLOOR SIMILAR 53
55 PLUMBING FIXTURES Hose Bibb JR Smith 5509QT Hose Bibb As needed. JR SMITH 5509 QT 54
56 PLUMBING FIXTURES Trap Primer Precision Plumbing Products As needed As needed PRECISION PLUMBING PRODUCTS 55
57 RESTROOM FIXTURES Urinal American Standard Allbrook White None. AMERICAN STANDARD
58 RESTROOM FIXTURES Service Sink Faucet Chicago 305-VB-R As needed. CHICAGO 305-VB-R 57
59 RESTROOM FIXTURES Toilet American Standard Afwall White Wall Hung None. AMERICAN STANDARD
60 RESTROOM FIXTURES Strainer Chicago 327ACP As needed. CHICAGO STRAINER 327ACP 59
61 RESTROOM FIXTURES Auto Faucet (Lavatory) Chicago Hytronic Traditional None. CHICAGO HYTRONIC TRADITIONAL
62 RESTROOM FIXTURES Auto Flusher (Toilet) Sloan 111ESS 186-1ESS Toilet Urinal None. SLOAN 111ESS AND 186-1ESS 61
63 RESTROOM/JANITORIAL FIXTURES Service Sink Commercial Enameling 871 As needed. CECO SINKS
64 RESTROOM FIXTURES Water Closet Seat Olsonite 95C Elongated, Open Front, White As needed. OLSONITE MODEL 95C 63
65 RESTROOM FIXTURES Toilet Compartments & Urinal Screens Bobrick 1090 Series Sierra Series Water & Fire Resistant Solid Color Reinforced Composite Toilet Partitions & Urinal Screens Bobrick Sierra Series Solid Phenolic w/ heavy duty hardware, continuous brackets BOBRICK 1090 SERIES 64
66 RESTROOM FIXTURES Toilet Compartments & Urinal Screens Bobrick 1090 Series Sierra Series Water & Fire Resistant Solid Color Reinforced Composite Toilet Partitions & Urinal Screens Bobrick Sierra Series Solid Phenolic w/heavy duty hardware, continuous brackets BOBRICK 1090 SERIES 65
67 RESTROOM FIXTURES Self-Draining Counter Top Corian Vanity Tops None. CORIAN VANITY SERIES 66
68 Shower Shapes Self-Draining Solid Surface Countertop Specifications I. GENERAL 1.01 DESCRIPTION A. Work described in this section: 1. Custom manufactured self-draining countertops. B. Related work specified elsewhere: 1. Tile Work. 2. Wall coverings. 3. Plumbing REFERENCES A. Applicable standards: Standards of the following, as referenced herein: 1. American National Standards Institute (ANSI) 2. American Society for Testing Materials (ASTM) 3. National Electrical Manufacturers Association (NEMA) 4. Federal Specifications (FS) 1.03 SUBMITTALS A. Shop Drawings: Indicate dimensions component sizes, fabrication details, attachment provisions and coordination requirements with adjacent work. B. Samples: Submit minimum 2"x2" (50mm x 50mm) samples. Indicate full range of color and pattern variation. Approved samples will be retained as standards for work. C. Product data: Indicate product description, fabrication information and compliance with specified performance requirements. D. Maintenance data: Submit manufacturer's care and maintenance data, including repair and cleaning instructions. Include in project close-out documents QUALITY ASSURANCE A. Allowable tolerances: 1. Variation in component size + 1/8" (3mm). 2. Location of accessory openings + 1/8" (3mm) from indicated location DELIVERY, STORAGE AND HANDLING A. Package materials to prevent damage to components during shipment. B. Deliver no components to project site until areas are ready for installation. Store components indoors prior to installation. Handle to prevent damage to finished surfaces. 67
69 1.06 WARRANTY A. Provide manufacturer's 3 year warranty against defects in fabricated products. Warranty shall provide replacement only. Labor to replace defective products is not included. Damage caused by physical or chemical abuse will not be warranted. II. PRODUCTS 2.01 SELF-DRAINING COUNTERTOP FABRICATIONS A. Specified product: Self-Draining Countertop from ShowerShapes B. Material: Homogeneous filled acrylic; not coated, laminated or of composite construction; meeting ANSI Z124.3 & 6, Type Six, and Fed. Spec. WW-P-541E/GEN. 1. Material shall have minimum physical and performance properties specified in the chart following Section D. 2. Superficial damage to a depth of 0.010" (.25mm); shall be repairable by sanding. C. Self-draining countertop components of 1/2" (13mm) thick Hi-Macs from LG Chemical. ShowerShapes self-draining countertops have a built-in drainage slope, coved backsplash, no-drip edge and accept, single or multiple LG Hi-Macs bowls for installation on, cabinets or ShowerShapes structural steel frames. D. Location of sinks to be specified by Architect. E. Performance requirements: (SEE Performance Requirements Page) 2.02 ACCESSORY PRODUCTS A. Joint Adhesive: Manufacturer's standard two-part adhesive kit to create inconspicuous, nonporous joints, with a chemical bond. (ref: Technical Bulletin: CTDC 102) B. Wall hung unit includes ShowerShapes structural steel bracket ready for installation FABRICATION A. All pre-fabricated Self-Draining Countertop components to be supplied by manufacturer. B. Components to be fabricated by ShowerShapes to greatest extent practical to sizes and shapes indicated, in accordance with approved shop drawings and manufacturer's requirements. C. Joints between components shall be formed using manufacturer's standard joint adhesive. Joints shall be inconspicuous in appearance and without voids. D. Component edges shall have a smooth, uniform finish. Defective or inaccurate work shall be repaired or replaced. E. Finish: All surfaces shall have a uniform matte finish. 68
70 III. EXECUTION 3.01 INSTALLATION A. After accepting components, installer assumes responsibility for damage occurring during installation. Installer shall install floor plumb and level, in accordance with approved shop drawings and product installation instructions. B. Components shall be clean and defect free on Date of Substantial Completion. C. Components damaged after Completion/Acceptance can be repaired or replaced if repair cannot be made to architect's satisfaction. Repair cost will be borne by the Party causing the damage. Architect to approve cost estimate before repairs or replacements are made. D. Care and maintenance video and product warranty information can be provided by ShowerShapes to the Project manager for review with the head of maintenance upon completion of project. 69
71 RESTROOM FIXTURES Compact Fluorescent Lightolier 1002F1 LAWA approved alternate. LIGHTOLIER 1002F1 COMPACT FLUORESCENT 70
72 RESTROOM FIXTURES Automatic Air Freshner Technical Concepts Model# Automatic Air Freshner None. TECNICAL CONCEPTS AIR FRESNNER MODEL#
73 RESTROOM FIXTURES Recessed Down Light Lightolier 1045 Lytecaster Recessed Downlighting Trim LAWA approved alternate. LIGHTOLIER DOWNLIGHT
74 RESTROOM FIXTURES 6 Compact Fluorescent Downlight LSI Lightron Inc. Series 206CFLH Recessed downlighting. LAWA approved alternate. LSI LIGHTRON INC SERIES 206CFLH 73
75 RESTROOM FIXTURES Linear Wall Mounted 6 X6 Fluorescent LSI Lightron Inc. Series99W Perimeter lighting. LAWA approved alternate. LSI LIGHTRON INC SERIES 99W 74
76 RESTROOM FIXTURES Fluorescent Perimeter Lighting LSI Lightron Inc. Series900 Perimeter lighting. LAWA approved alternate. LSI LIGHTRON INC SERIES
77 RESTROOM FIXTURES Fluorescent Perimeter Prudential Lighting P-60-2T8-04-NS- Perimeter lighting. LAWA approved TMW-D2 Lighting alternate. PRUDENTIAL LIGHTING SURFACE MOUNTED FLUORESCENT 76
78 RESTROOM FIXTURES Fluorescent Perimeter Prudential Lighting IT8-04 (08 )-BLA- Perimeter lighting. LAWA approved SC-X4B-B Lighting alternate. PRUDENTIAL LIGHTING RECESSED MOUNTED FLUORESCENT 77
79 END 78
PUBLIC RESTROOMS, DESIGN INTENT
PUBLIC RESTROOMS, DESIGN INTENT 1.01 STRUCTURAL A. Where feasible, metal stud partitions will be constructed on a 6 high concrete curb. 1.02 MECHANICAL A. Restrooms will have a minimum of 15 air changes
WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST
0 RIVERSIDE DRIVE, OTTAWA, ON A0.0 COVER SHEET / DRAWING LIST A0. LEGEND AND GENERAL NOTES A0. GENERAL NOTES A0. GENERAL NOTES A0. TYPICAL WASHROOM WALL/SINK SECTION A0. DETAIL - CONTROL JOINT A0. DETAIL
INSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS
INSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS 1. Paragraph 1.02 Provide solid surface countertops at sinks locations. Provide solid surface window sills at drywall framing walls.
Seattle Tacoma International Airport Restroom Standards
Seattle Tacoma International Airport Restroom Standards Last Updated July 10, 2015 Contents Introduction... 2 General Restroom Features:... 2 Mock up During Design... 2 Doorless Entry... 2 Entry Identification
604 Water Closets and Toilet Compartments
604 Water Closets and Toilet Compartments 604.1 General. Accessible water closets and toilet compartments shall comply with Section 604. 604.2 Location. The water closet shall be positioned with a wall
Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN 46787 Phone (260) 723-5131 Sales Fax (260) 723-6396 whitley@whitleyman.
Building Type Building Code Whitley Classroom Buildings BOCA, UBC, SBCCI, NEC, ADA Structural Support Outrigger construction standard, Whitley model classrooms. Main support beams to be 12 11.8# per lineal
Bath Planning Guidelines With Access Standards
Bath Planning Guidelines With s 1: Door/Entry The clear opening of a doorway should be at least 32. This would require a minimum 2-10 door. If the existing structure precludes changing the opening then
SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
CLEAR-DIVISIONS CENTERFOLD
CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
09 00 03 GENERAL PROVISIONS
09 00 03 GENERAL PROVISIONS A. For renovation projects, consider the building s character and existing finishes. All material patches should blend as closely as possible. Some buildings on campus have
ADA Design Guide Washrooms & Showers
ADA Design Guide Washrooms & Showers Accessories Faucets Showers Toilets Lavatories interactive version available at bradleycorp.com/adaguide.pdf Accessible Stall Design There are many dimensions to consider
Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing
Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD The universal substrate for tiles Flat. Level. Plumb. Square. No matter the quality, cost, or extravagance of
CLEAR-DIVISIONS VARIOFOLD
CLEAR-DIVISIONS VARIOFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS VARIOFOLD moveable The yellow highlighted areas in the
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
Point Auditorium Design Narrative PROJECT NAME: Point Auditorium DATE: 06/25/15 TO: Lance Francis FROM: Leslie Ellsworth
INTRODUCTION: Kronberg Wall Architects is pleased to present the Design Narrative for the Point University Auditorium conversion from the existing warehouse space. General Project Description: This project
Typical storey plan with two toilet clusters SANITARY PROVISION SANITARY PROVISION. Individual washroom. Standalone, unisex individual washroom
ACCESSIBLE TOILET REQUIREMENTS Code 2007 o Where toilets are provided at every level of a building Accessible individual washroom or WC compartment can be provided Disadvantage If WC compartment is provided,
SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY
SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY Construction Criteria The unit costs for (Wet) space types are based on the construction quality and design features in the following table. This
SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
The emergency provisions affect the following Building Code sections:
On August 1, 2012 new emergency chapter 11B code provisions became effective. Attached are copies of the emergency express terms and the applicable figures. The new requirements are underlined and deleted
Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
Window Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
SECTION 22 42 00 COMMERCIAL PLUMBING FIXTURES
SECTION 22 42 00 COMMERCIAL PLUMBING FIXTURES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
How To Make A House Safe
1 RESIDENTIAL Screen Enclosures Orange County Residential Code Compliance Alternative design method for screen enclosures R301.2.1.1.3 PLAN REVIEW Engineered plans must state that the Alternative Design
BRADLEY HALO EMERGENCY PLUMBING FIXTURES
BRADLEY HALO EMERGENCY PLUMBING FIXTURES Bradley Halo Emergency Plumbing Fixtures are a new generation in safety equipment, featuring separate supply and waste piping to eye/face wash, ergonomic hand activation
BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)
BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version) Bradley Halo Emergency Plumbing Fixtures are a new generation in safety equipment, featuring separate supply and waste piping to eye/face wash,
Irvinton Village Apartments 2901 Fulton Houston, Texas 77009 Houston Housing Authority J. Allen Management Managing Agent
Irvinton Village Apartments 2901 Fulton Houston, Texas 77009 Houston Housing Authority J. Allen Management Managing Agent Scope for Irvinton Village Unit #512 Overall Scope: Demolition, Renovation, and
www.koalabear.com Toll Free: 888-733-3456
Koala presents a complete line of Baby Changing Station models with Microban antimicrobial product protection. In addition, Koala offers a comprehensive line of Child Seating options for foodservice, retail,
Building Condition Assessment Report
C2 - Nurses Resident (aka Administration) Building Condition Assessment Report Asset Address Address Construction Year Size (Gross Floor Area) Asset Type Floors Above Ground Inspection Date C2 - Nurses
Page 1 of 6 COMPLIANCE CHECKLIST. > Long Term Care Facility - Nursing Unit
COMPLIANCE CHECKLIST Page 1 of 6 > Long Term Care Facility - Nursing Unit The following checklist is for plan review of new long-term care facilities and new additions to existing long-term care facilities.
Sealant. 30" Model No. 35020. D: 17-7/8" TO 18-3/8" (454 to 466mm) W: 29-3/4" TO 30-1/4" (756 to 768mm) Under Countertop Installation
INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE London Kitchen Sinks 24" Sink model number 35030 30" Sink model number 35020 36" Sink model number 35040 Thank you for selecting Porcher. To ensure this product
12.1 Schlüter -KERDI-BOARD
I n n o v a t i v e p r o f i l e s 12.1 Schlüter -KERDI-BOARD S u b s t r a t e U N I V E R S A L S T R U C T U R A L P A N E L, B O N D E D W A T E R P R O O F I N G Application and Function Schlüter
CLEAR-DIVISIONS APERTO
CLEAR-DIVISIONS Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS moveable glass wall system. The yellow highlighted areas in the
17,280 square feet Overview:
CENTRAL OFFICE Located at 167 Boston Post Road, East Lyme, Connecticut, the Central Office was built in 1916 as the original Flanders Elementary School and remains connected to the current school. The
glass & Glazing Products
glass & Glazing Products WallMaker Create an unlimited variety of bright, beautiful and secure interior environments with the easy-to-install Stylmark WallMaker glass wall system. This versatile system
THINGS YOU SHOULD KNOW
INSTALLATION INSTRUCTIONS Value Sized Roll The quickest, easiest, cleanest way to install tile. No Mortar, No Mixing, No Mess Complete Your Project in a Day No Waiting Between Setting and Grouting THINGS
COST OF WORK FORM. Abbreviations: ea = each, LF = linear feet, SF = square feet, HSF = square feet of living area (including garage conversion space)
COST OF WORK FORM All costs shown are estimates using base grade materials, taxes, and labor. For houses where a higher quality is indicated, the costs should be increased for work requiring upgraded materials.
Your Basement Remodeling Specialist LLC
Your Basement Remodeling Specialist LLC Contents Introduction 3 Remodel Details 4 Basement Bid Scope 5 Financial Arrangements 6 Homeowners Shopping Guide 7 The following is provided with your actual quote:
KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS
St. Louis County Department of Public Works Division of Code Enforcement KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS This guideline is intended to provide the homeowner/contractor with the
Schluter -Shower System Installation Handbook 2014. Bonded Waterproofing System for Tiled Showers, Steam Showers, Steam Rooms, and Bathtub Surrounds
Schluter -Shower System Installation Handbook 0 Bonded Waterproofing System for Tiled Showers, Steam Showers, Steam Rooms, and Bathtub Surrounds Schluter -Shower System Bonded Waterproofing System for
Saferand easierinstallation
EN 85-07 Saferand easierinstallation IföSigninstallationsystem andifösignbuilt-incistern www.ifosanitar.com/sign Aneffectivesolution withmanyadvantages. Ifö Sign installation system makes life a little
FUTRUS WALL-MOUNT VANITY SINK SOLUTIONS WITH DUPONT CORIAN
FUTRUS WALL-MOUNT VANITY SINK MODEL FWS_3018R ADA PRODUCT SPECIFICATION The wall-mount vanity sink shall be made of Corian solid surface. Bathroom module shall be 30 (762 mm) in length, 18 (457 mm) in
Sun Windows General Information Sun New Construction Window Installation Instructions
Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten
Carriers, Fixtures & Piping
Regardless of application and/or installation needs, there are fixture supports available to meet even the harshest design requirements. by William M. Smith Over the years, I m sure that each of you in
Base Cabinet with Self-storing Folding Doors and Floor
Usable Kitchens When designing a kitchen for use by persons with mobility impairments, especially those who use wheelchairs, careful layout of the kitchen is crucial to maintaining accessibility. People
Installation Manual. Toilet Partitions, Dressing Compartments & Shower Stalls
Installation Manual Toilet Partitions, Dressing Compartments & Shower Stalls Metpar Corp 95 State Street, Westbury, New York, USA, 11590 Tel: 516-333-2600 Fax: 516-333-2618 Internet: http://www.metpar.com
BUILDING PERMIT SPECIFICATIONS
BUILDING PERMIT SPECIFICATIONS The below noted requirements are based upon La Plata County Building Code. These specifications are not intended as a complete set of requirements, but are intended to provide
Installation Guide. Bath and Wall Surrounds SERIES 7104 1021861-2-B
Installation Guide and Wall Surrounds SERIES 7104 1021861-2-B Thank You For Choosing Sterling We appreciate your commitment to Sterling value. Please take a few minutes to review this manual before you
3. Tile used in the toilets is generally in good shape, though somewhat dated looking. The floor tile is slippery when wet.
Architectural Elements Support Facilities A. System Description 1. Architectural support facilities include the lobby, classroom, fitness room, office area, staff toilet/showers, public toilet/lockers,
FIX TURE CARRI ERS. 140(a) MPB-2011-USA
FIXTURE CARRIERS STRUCTURAL FEET The feet are heavy duty cast ductile iron and invertible. No distinction is necessary between right and left hand. Each foot wraps around the specially formed edge of the
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
City of Wichita, Kansas Americans with Disabilities Act Transition Plan Main Library Address
City of Wichita, Kansas Americans with Disabilities Act Transition Plan Main Library Address July 005 Prepared by DMCG Disability Management Consulting Group L.L.C. 801 Jonquil Place Columbia, MO 650 In
Automatic Door Selection Guide
Automatic Door Selection Guide AAADM 1300 Sumner Avenue Cleveland, OH 44115 P: 216-241-7333 F: 216-241-0105 [email protected] Automatic Door Selection Guide General: The members of AAADM manufacture an assortment
Building Condition Assessment Report
Building Condition Assessment Report Asset C3c - Oak Terrace Cottage 121 Address Riverview Lands, 2601 Lougheed Highway, Coquitlam, BC. V5C 4J2 Construction Year Size (Gross Floor Area) 1920. 2,553 Sq.Ft.
SECTION 02630 STORM DRAINAGE SYSTEM
SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE
SCHLUTER -KERDI-BOARD
SCHLUTER -KERDI-BOARD S U B S T R AT E S U B S T R AT E, B U I L D I N G PA N E L, B O N D E D W AT E R P R O O F I N G Application and Function 12.1 Schluter -KERDI-BOARD Schluter -KERDI-BOARD is a multifunctional
Schedule of Maintenance Fees
Schedule of Maintenance Fees Effective July 1, 2015 It is the policy of the Housing Authority of Murray not to charge for NORMAL wear and tear. However, the Housing Authority reserves the right in every
8.7 Schluter -KERDI-LINE
8.7 Schluter -KERDI-LINE INNOVATIVE SOLUTIONS FOR CERAMIC AND STONE TILE LINEAR DRAINS FOR BONDED WATERPROOFING ASSEMBLIES Application and Function 8.7 Schluter -KERDI-LINE is a low profile linear floor
Wastewater Capital Projects Management Standard Construction Specification
CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 Precast Concrete Pipe 10.1.1 General This section covers material requirements,
R432. Health, Health Systems Improvement, Licensing. R432-5. Nursing Facility Construction. R432-5-1. Legal Authority. R432-5-2. Purpose.
R432. Health, Health Systems Improvement, Licensing. R432-5. Nursing Facility Construction. R432-5-1. Legal Authority. This rule is promulgated pursuant to Title 26, Chapter 21. R432-5-2. Purpose. The
SECTION 11 78 13 MORTUARY REFRIGERATORS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in
RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES
1807 Elmwood Avenue, Suite 275 Buffalo, New York 14207 (800) 543-5155 RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES Fiberesin Wall System Provide materials and labor to complete courts
What to Expect From the Examination. How to Study the Plumbing Codes
Texas State Board of Plumbing Examiners Plumbing Inspector Examination Review Course The following Examination Review Course is designed to assist an applicant in preparing for the Plumbing Inspector examination.
HEALTH FACILITY CHECKLIST SECTION 1226 [OSHPD 3] CLINICS 1226.6 PRIMARY CARE CLINICS
Compliance Checklist: [OSHPD 3] Primary Care Clinics Page 1 of 7 HEALTH FACILITY CHECKLIST SECTION 1226 [OSHPD 3] CLINICS 1226.6 PRIMARY CARE CLINICS Primary Care Clinics are Health Facilities licensed
Borges Construction Company A limited liability Corporation Page1 of 1
Page1 of 1 The following is a quote to remodel the master bathroom at your home: Materials Labor Demolition 1 Dumpster $ 225.00 $ - 2 Remove existing carpet $ - $ 50.00 3 Remove existing tile $ - $ 80.00
TOLL FREE: (866) 591-7792. E-Mail: [email protected]. www.vigoindustries.com VANITY SPECIFICATIONS. VANITY COMPONENTS Model VG09042K1
VANITY SPECIFICATIONS VANITY COMPONENTS Model VG09042K1 MODEL VG09042K1 FEATURES Freestanding cabinet Soft closing sliding cabinet drawer hardware White, single hole ceramic sink Cabinet ships assembled
IMPROVEMENT COST ESTIMATE powered by HomeFixers
IMPROVEMENT COST ESTIMATE powered by HomeFixers 123 Main St, Anytown, USA 12345 2000 SF $ 45,041.06 100.0% $22.52 per sq. ft. Stage 1: Pre-Construction $ 1,461.00 3.2% 1 House Secured $ 106.00 0.2% Lockbox
LOADING DOCK EQUIPMENT. A. Section 03100 - Concrete Forms and Accessories: Placement of anchors into concrete.
LOADING DOCK EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Loading dock equipment of the following types: 1. Dock lifts. 2. Control stations. 1.2 RELATED SECTIONS A. Section 03100 - Concrete Forms and
Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components
Infrastructure Facility Condition Summary Weighted Avg Condition Score Facility Components Systems Surveyor/ Date Done Comments G Sitework.9 Site Improvements Parking Pedestrian Paving Site Development
Gramercy Place Condo Association, Inc.
Gramercy Place Condo Association, Inc. UNIT MODIFICATION REQUEST Date of Application: Name of Owner (s): Telephone: (Home) (Cell) E-Mail: Anticipated start date: Anticipated ending date: Permission is
Module 7. Plumber: Sink Installation
Module 7 Plumber: Sink Installation 138 The picture below shows a sample sink installation station. 139 Module 7 Plumber: Sink Installation Module Overview This module will involve the proper setup and
Your Company Name. Your Company Address Your City, State, Zip Your Phone Number Your Email Address. Project Information
Your Company Address Your City, State, Zip Your Phone Number Your Email Address Customer Information John Smith 0 Sandy Lane Blvd Tampa, FL 3342 Project Information Estimate Prepared By: Jones Estimating
Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11
Cluster Box Units (CBU s) continued on pages 7-11 CLUSTER BOX UNITS FRONT LOADING Made of heavy duty aluminum and stainless steel hardware, Salsbury 3300 series U.S.P.S. approved Cluster Box Units (CBU
Certification: Building Plans Examiner. Exam ID: B3
Certification: Building Plans Examiner Exam ID: B3 Scope: A Building Plans Examiner will be responsible for reviewing submitted plans to determine if they meet the requirements of the various Building
ACCESS AUDIT OF WESTPORT HOUSE
ACCESS AUDIT OF WESTPORT HOUSE Large sign on the highway to indicate the entrance to Purbeck District Council Large and wide entrance Entrance showing sign for opening times Entrance sign Main entrance
LEASE BETWEEN RALEIGH PORTFOLIO JH RETAIL, LLC AND CITY OF DURHAM FOR SPACE IN THE BUILDING AT 2945 S. MIAMI BOULEVARD; DURHAM, NC EXHIBIT A
EXHIBIT A SCOPE OF WORK TO BE COMPLETED BY LANDLORD FOR THE DISTRICT 4 POLICE SUBSTATION AT 2945 S. Miami Boulevard, SUITES 133,134,135, and 136 Dated August 21, 2012 All work must be done in compliance
SECTION 14 20 10 - FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL
SECTION 14 20 10 - FREIGHT & PARKING GARAGE PART I - GENERAL 1.1 SECTION INCLUDES [NOTE to AE: The following lists requirements that are specific to freight elevators. These requirements are in addition
SECTION 6. Glass Storefront Doors:
SECTION 6 Glass Storefront Doors: Table of Contents 3070 Storefront Door System Description & Dimensions 6070 Storefront Door System Description & Dimensions Door Leaf Detail Optional 10 Bottom Rail Detail
Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery
Alpha System ADAPTABLE LABORATORY FURNITURE KEWAUNEE encouraging new discovery Alpha 6 partition modules with Kemresin worktops. Minneapolis, Minnesota Alpha 6 partition modules with Alpha overhead service
ATTACHMENT A STRUCTURAL INTERIOR DESIGN (SID) REQUIREMENTS
ATTACHMENT A STRUCTURAL INTERIOR DESIGN (SID) REQUIREMENTS 1.0 GENERAL INFORMATION Structural Interior Design includes all building related elements and components generally part of the building itself,
Universal Design Recommendations for Accessible University Settings. Mauricio A. Lizama, Ph.D., ATP
INFORME TÉCNICO Unidad de Diseño, Desarrollo y Evaluación de AT PRATP Septiembre, 2009 Universal Design Recommendations for Accessible University Settings Mauricio A. Lizama, Ph.D., ATP The features listed
DuPont Surfaces. DuPont TM Corian Lavatories. TECHNICAL bulletin
DuPont Surfaces DuPont TM Corian Lavatories TECHNICAL bulletin TABLE OF CONTENTS PAGE SECTION 3 Illustration of ADA Guidelines Used 3 Options for Counters Placed 34 from Floor 4 Model 810 with Front Overflow
London Farm Kitchen Sinks
INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE London Farm Kitchen Sinks 24" Sink model number 35120 30" Sink model number 35130 36" Sink model number 35140 Certified to comply with ANSI A112.19.3.M CAN/C.S.A
220.5" Basic Features. Electrical Features
8'x20' GENESIS UNIT 19.5" 220.5" Basic Features Durable, heavy duty steel construction to ISO standards Large, 5mm-thick windows with screens, blinds, removable metal window shutters Fully finished rigid
TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER 1.800.591.9360 TECHNICAL ASSISTANCE FAX: 1.626.855.4894
ACORN SAFETY P.O. BOX 3527 CITY OF INDUSTRY, CA 9744-0527 UNITED STATES OF AMERICA WWW.ACORNSAFETY.COM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FREEZE RESISTANT WALL MOUNTED EMERGENCY EYEWASH
SCHEDULE OF FINISHES AMBLE RIDGE RETIREMENT VILLAGE
SCHEDULE OF FINISHES AMBLE RIDGE RETIREMENT VILLAGE SITEWORKS FOUNDATIONS & SURFACE BED Site to be cleared and leveled. Builder s rubble to be carted away. As per Engineer s design, with USB green waterproofing.
WAW-2311 WAW-2322 WAW
COMMERCIAL PRODUCT GUIDE Plumbing Fixtures & Accessories MADE IN THE USA Willoughby Industries has manufactured commercial grade stainless steel and solid surface plumbing products for more than 65 years.
AIR RELEASE, CLEANOUT, AND SEWER MANHOLES
AIR RELEASE, CLEANOUT, AND SEWER MANHOLES **From Hartford IM BLDG(10) DESCRIPTION. This work shall consist of the construction of air release, cleanout, and sanitary sewer manholes; and the furnishing
SECTION 1 GENERAL REQUIREMENTS
Page 1 of 6 SECTION 1 GENERAL REQUIREMENTS 1. SCOPE OF WORK: The work to be performed under the provisions of these documents and the contract based thereon includes furnishing all labor, equipment, materials,
9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.
Section 9.8. Stairs, Ramps, Handrails and Guards 9.8.1. Application 9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and
PLUMBING ROUGH IN INSPECTION
This Program is made Possible through the Code Officials Education & Training Fund. Revenue for the Fund comes from Assessments on Building Permits. Please turn down cell phones and put pagers on vibrate.
Expanding Your Market
U.S. Department of Justice Civil Rights Division Disability Rights Section Expanding Your Market Maintaining Accessible Features in Retail Establishments Introduction More than 50 million Americans with
1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.
SECTION 075416 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. 1.2 PERFORMANCE REQUIREMENTS A. Solar Reflectance
SECTION 221413 FACILITY STORM DRAINAGE PIPING
SECTION 221413 FACILITY STORM DRAINAGE PIPING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
SECTION 02400 - STORM DRAIN SYSTEM
SECTION 02400 - STORM DRAIN SYSTEM CONTENTS: Part 1 - General... 1 1.01 Work Included... 1 1.02 Related Requirements... 1 1.03 Reference Standards... 1 1.04 Quality Assurance... 1 1.05 Measurement And
Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association
Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-
SECTION 32 31 13 CHAIN LINK FENCES AND GATES
PART 1 GENERAL 1.1 DESCRIPTION SECTION 32 31 13 CHAIN LINK FENCES AND GATES SPEC WRITER NOTES: 1. Delete or add information between //---// and any other items applicable to project. Cover any item added