8 Steamers. Introduction
|
|
|
- Jasmin Long
- 9 years ago
- Views:
Transcription
1 8 Steamers Introduction Commercial steamers provide an easy, fast way to prepare large quantities of food. Steaming offers good nutrient retention, short cook times, and ease of preparation; little attention is needed from the chef, food can be cooked and served in the same pan, and cleanup is simple. Steamers are versatile appliances that can be used to prepare almost any food that does not require a crust. Delicate vegetables such as asparagus and broccoli are cooked without damage, frozen foods are defrosted and cooked in one step, and hard-to-cook meats such as beef ribs can be par-cooked more quickly and with less weight loss than oven roasting. In appearance, the compartment steamer resembles an oven. The cavity is typically rectangular on atmospheric steamers, and may be oval or round on pressure steamers. The door is gasketed and windowless. Controls are front-mounted. Figure 8-1 shows a typical two-compartment steamer atop a boiler base. Figure 8-1. Two-compartment convection steamer on self-contained base. Photo: Fisher-Nickel, inc. Steamers come in a variety of configurations, including countertop models, wall-mounted models and floor models mounted on a stand, pedestal or cabinet-style base. A steamer may consist of one to four stacked cavities. The cavity is usually designed to accommodate a standard 12 by 20-inch (300 mm x 500 mm) hotel pan. Smaller steamers may be designed for use with one-third size pans, and some large steamers can hold several 18 by 26-inch (460 mm x 660 mm) baking trays. The steam itself can be produced several ways. Many compartment steamers have an external (with respect to the cooking compartment) electric, gas, or service-steam powered boiler that produces potable steam under pressure. This pressurized steam is delivered to the cooking compartment as demanded by the control settings. However, in the case of a pressureless steamer (see Figure 8-1), the compartment is openly connected to a condensate drain and the steam environment within the compartment cannot sustain a pressure above atmospheric (both raw steam and condensate exit the cooking cavity
2 through this drain). In the case of a pressure steamer, only condensate is allowed to drain. Thus the cooking cavity is allowed to build up to the operating pressure of the boiler. In the larger boiler-based designs, there may be additional steam capacity (referred to as a power-take-off or PTO) to power other appliances such as a steam-jacketed kettles installed along side the steamer. Steam also may be produced by a steam generator located within (or directly connected to) the cooking cavity. This method differs from the boiler-based steamers in that the steam is produced at (or slightly above) the compartment operating pressure (i.e., atmospheric pressure). This strategy is not used for pressure steamers. A steamer may produce steam by boiling water poured directly into the cooking compartment prior to operation (this is the simplest form of an internal steam generator, typically referred to as a connectionless steamer). Heating elements are located either beneath the compartment s floor or placed directly in the bottom of the compartment. Gas burners, placed below the compartment, may produce steam in the same fashion. Steam may be supplied from an external source (e.g., centralized building steam). If this steam is clean, it can be routed directly to the steamer compartments. Otherwise, it can be run through a heat exchanger and used to generate potable steam from clean water. Boiler-based and conventional steam-generator type steamers require a drain line, water line, and a connection to an energy source typically gas or electricity. Self-contained units typically have boilers that fill automatically. Condensate from the cavity is directed to a drain tube, where it is cooled by a stream of water before flowing into the sewer (In many areas it is against code to drain water above 140 F). The new generation of connectionless steamers require no such connections beyond the electrical (or gas) hook up. Water is poured into the bottom of the cooking compartment and periodically refilled during the course of operation. When operation is suspended, the water is drained from the cavity into a pan or bucket
3 Cooking Process Steam cooking exploits the latent energy that steam at 212 F (100 C) carries, which is six times greater than water at the same temperature. When steam condenses on the surface of cold food, it transfers this latent energy to the food. If the pressure inside the steamer compartment rises, the steam can reach higher temperatures and deliver more energy to the food. This is the mechanism behind pressurized steamers, which may cook food faster than pressureless (atmospheric) steamers. As with baking, a layer of insulating vapor can form around food in a still steamer cavity. The natural convection inside the cavity tends to strip away this insulating layer of air, but it has a limited ability to do so. If food is tightly packed, or if the steamer is fully loaded with pans, convection is impeded and cooking slows down. The last few years have seen the addition of a fan to some steamers. Forced convection in a steamer (e.g., via steam being injected from the boiler) has the same effect as it does in a convection oven, namely stripping away the insulating layer of vapor around the food to speed cooking and provide even heat throughout the steamer cavity. Types of Steamers There are two basic categories of steamers on the market, pressureless (atmospheric) and pressurized. Each type is available in gas, electric and directsteam models. Pressureless Steamer Pressureless steamers, also commonly referred to as "atmospheric" steamers, maintain the cooking compartment at close to atmospheric pressure (between 0 and 2.9 psig (0 and 20 kpa)). They generally employ a large cooking cavity to facilitate the circulation of steam around the food product. Because these steamers operate at or near atmospheric pressure, the door may be safely opened at any point during the cooking cycle to check the product. Many atmospheric steamers employ a fan for forced convection steaming, to produce shorter cook times and even cooking throughout the compartment under full-load conditions
4 Pressure Steamer Pressure steamers employ a closed system to allow the steam to build pressure inside the cooking compartment. These steamers are easily identifiable by their smaller compartments and heavy locking doors (see Figure 8-2). Although these steamers may cook smaller batches of food than pressureless steamers, cook times can be shorter, and energy efficiency higher, depending on the food product. Figure 8-2. Two-compartment pressure steamer. Photo: Fisher-Nickel, inc. Low-pressure steamers typically operate between 3 and 9 psig (20 and 62 kpa). These are high-volume steamers that are often used in schools and hospitals. High-pressure steamers generally have smaller compartments and operate at 10-15psig ( kpa). Although they hold less food, they may cook up to twice as fast as a low-pressure steamer. Pressure steamers require precise cook times because the food product cannot be checked while the steamer is operating. Advanced Steamer Technologies Pressureless steamers vary in their technological complexity. In addition to the three primary designs (boiler, steam-generator, and connectionless), manufacturers have employed different strategies for improving performance and reducing energy consumption. These emerging technologies include convection, vacuum pumps, close-system design, connectionless designs, compartment insulation and a stand-by mode. Convection. Turbulent steam strips away the insulating layer next to the food, for faster cooking that is more even throughout the cavity. There are two basic methods of producing this forced convection. Some manufacturers inject steam into the cavity through jets in the cavity wall, while others use a fan to circulate the steam within the compartment. Vacuum Pumps. Vacuum pumps have been used to reduce the pressure within the cooking compartment and lower the cooking temperature. This technology is promoted to reduce cook times and be gentler on delicate food products
5 Closed System. One manufacturer employs a unique steam-control system that monitors pressure fluctuations within the cooking compartment, which reflects how much steam is being condensed on the food during the cooking process. As pressure builds in the compartment and less steam condenses, the unit s steam generator will suspend steam production. Only when the compartment pressure lowers, indicating that the food has absorbed heat from the steam, will the steam-generator reactivate. Figure 8-3. Connectionless steamer. Photo: Stellar Steam. Connectionless Design. Connectionless steamers have a water reservoir in the bottom of the cooking compartment in lieu of a water connection. The reservoir is manually filled and drained. Connectionless steamers have an advantage in that no steam leaves the cooking cavity during operation (except through a compartment vent). Thus, steam that does not condense on the food remains within the cavity, thereby significantly improving the steamer s energy performance. This strategy also mitigates some of the difficulties associated with boiler maintenance, and allows easier access for cleaning. Figure 8-3 shows a typical connectionless steamer. One manufacturer of a connectionless steamer incorporates a vacuum that reduces the temperature of steam (below 212 F) to provide a more gentle cooking event. Compartment Insulation. Improved insulation around the cooking compartment reduces heat loss to the kitchen and can have a significant effect on standby (idle) energy consumption. Standby Mode. Some manufacturers maintain a steam generator stand-by temperature just below boiling (typically, 180 to 200 F). This allows the appliance to produce steam seconds after the steamer is loaded with food product and is a practical alternative to turning the steamer off between uses. Cook times may be slightly longer than if the steamer had been held at full input, as the cavity also absorbs heat. The increase in cook time depends on when the steamer was last used (leaving residual heat in the walls of the cavity.) Controls Steamer manufacturers offer a wide range of control packages. Some units are equipped with only the necessary controls for operation: an on/off switch, water-refill light, and simple timer. Others have an array of features such as
6 boiler temperature, high- and low-power modes, idle/hold modes and other energy-saving settings. Timers can also terminate the cooking process to ensure that food product is not over cooked. Boiler-based units may also incorporate maintenance-indicator lights and an automated boiler blow-down mechanism to cleanse the heating elements or burner tubes of scale and sediment. Some steamers use compensating timers, which automate defrosting and cooking. As an example, consider a load of frozen fish being cooked in a steamer with a compensating timer. Cavity temperature is monitored, and the timer does not begin to count down until the compartment nears 212 F (100 C), a temperature that corresponds to the frozen food having mostly thawed. At this point, the timer-preset with the desired cook time for a thawed food product has "compensated" for the food's initial condition, whether it was frozen or thawed (as well as the cavity s initial condition, cold or preheated). In a pressure steamer, the drain valve would close at this point and pressurized cooking would begin. 1 Steamer Performance An ASTM Standard Test Method for Performance of Steam Cookers 2 developed by the (FSTC) allows manufacturers and users to gauge steamer-cooking performance directly, and to evaluate steamer energy consumption as well. As hard data on steamers has expanded, it is apparent that certain technologies and designs yield better performance. The ASTM method reports several parameters of steamer performance, including preheat energy and time, idle energy rate, and cooking-energy efficiency and production capacity under heavy- (full-load) and light-loading (single-pan) conditions with both green peas and red potatoes. Preheat Energy and Time Preheat energy and duration can be useful to food service operators for managing power demands, and knowing how quickly the steamer can be ready for operation
7 Typical preheat times can be between 5 and 20 minutes. Longer preheat times can discourage operators from turning units off between loads. Cook times can also be adversely affected by the unit s need to reheat the cavity walls as well as cook the food product. Some boiler-based units utilize compensating timers to address the challenge of reheating the cold compartment. Connectionless steamers, however, do not suffer this dilemma as the compartment is continually exposed to steam produced by the boiling water in the cooking compartment. Table 8-1 summarizes typical preheat time and energy consumption for various types of steamers. Table 8-1. Input Rate and Preheat Test Results for Different Steamers. 3 Elec 1 Elec 2 Gas 1 Gas 2 Energy Input Rate 26.3 kw 19.1 kw 254 kbtu/h 199 kbtu/h Preheat Time Heat-Up Time (min) Fill Time (min) Preheat Energy Consumption 5.3 kwh 1.0 kwh 28.1 kbtu 22.8 kbtu Idle Energy Rate Steamers spend the majority of the operating time in an idle, or stand-by condition. The idle energy rate of a steamer provides a good indication of its overall energy consumption use. Even in a busy restaurant, steamers may be idle 75% of the time. Figure 8-4 illustrates the range of normalized idle rates for three-pan, single-compartment steamers Frozen Green Pea Cooking-energy efficiency Frozen green pea cooking-energy efficiency is determined by cooking a full load of frozen peas (8 pounds (3.6 kg) of peas per pan) from a temperature of 0 ± 5 F to 180 F. Frozen green peas are representative of a typical frozen food product found on restaurant menus. As a test product, green peas are consistent in quality and readily available. More importantly, they yield consistent testing results that in turn provide reliable energy efficiency data
8 Normalized Idle Rate (kw) * Figure 8-4. Normalized electric pressureless steamer idle energy rates Test Steamer Number *Idle rates are normalized for 3-pan steamers. Red Potato Cooking-Energy Efficiency Red potato cooking-energy efficiency is determined by cooking a full load of red potatoes (8 pounds (3.6 kg) per pan) from room temperature (75 ± 5 F) to 195 F. As a tough-to-cook food product, red potatoes challenge the production capacity of a steamer more so than frozen green peas. With a low surface to volume ratio and a slower rate of condensation, potato-cooking tests can reveal far greater differences in cooking-energy efficiency between one steamer and another. In particular, the benefit of pressure steaming over atmospheric steaming becomes quite apparent when comparing red potato cooking energy efficiencies. Figures 8-5 and 8-6 compare the green pea and red potato cooking energy efficiencies for different types of steamers
9 Cooking-Energy Efficiency (%) Figure 8-5. Typical frozen green pea cooking-energy efficiencies of steamers Gas Boiler Based (Atmospheric) Gas Boiler Based (Pressure) Gas Steam Generator Electric Steam Generator Connectionless Cooking-Energy Efficiency (%) Figure 8-6. Typical red potato cooking-energy efficiencies of steamers Gas Boiler Based (Atmospheric) Gas Boiler Based (Pressure) Gas Steam Generator Electric Steam Generator Connectionless
10 Frozen Green Pea and Whole Potato Production Capacities Production capacity is the amount of food that can be cooked in a steamer in a given time. This figure is typically presented in product literature as the number of pounds of frozen vegetables that can be cooked per hour. Potatoes are a more stubborn food product and tend towards longer cook times than frozen peas. Figure 8-7 compares the frozen green pea production capacity for various electric pressureless steamers Figure 8-7. Normalized electric pressureless steamer production capacity. Normalized Production Capacity (lb/h)* Test Steamer Number *Production capacity is normalized for 3-pan steamers. Water Consumption and Condensate Temperature Water consumption is monitored during both green pea and red potato cooking-energy efficiency tests to determine the rate of water usage. Water consumption characterization is useful for estimating water and sewage costs associated with appliance operation
11 Condensate temperature is monitored during both cooking-energy efficiency tests. Measurement of condensate temperature is useful to verify that the temperature does not exceed regional building code limits. 3 Heavy-Load vs. Light-Load Efficiencies The ASTM test method specifies different loading scenarios for heavy-load (full-compartment) and light-load (single-pan) tests. The heavy-load tests represent a steamer s maximum performance. The cooking compartment is filled to capacity with food product and the steamer exhibits its peak efficiency during these tests. Light-load cooking-energy efficiency serves to ease comparisons between units of differing maximum compartment capacities. The cooking scenario also illuminates the wide disparity between steamers of differing cooking technologies. For example, boiler-based atmospheric steamers tasked with cooking a single pan of red potatoes can exhibit cooking energy efficiencies as low as 3%. Connectionless units typically exhibit cooking energy efficiencies of 30% or more under similar loading conditions. Benchmark Energy Performance Pressureless steamers exhibit dramatic differences in energy-efficiency, primarily depending on how the steam is produced and/or introduced and then maintained within the cooking compartment. The first-generation boilerbased steamers continually forced steam into the cooking compartment, whether or not the unit was cooking. Additionally, the boilers themselves rarely incorporated any insulation. This led to cooking energy efficiencies in the 25 to 30% range (determined under the full-load potato testing conditions of ASTM F ). Second-generation steamers employed an insulated compact steam-generator, which had significantly less heat loss than traditional boiler systems. The performance of these second-generation steamers still suffered from continuously supplying steam to the cooking compartment, leading to high idle energy consumption. Both of these approaches use an open-system design in which any steam injected into the compartment that does not condense on the food escapes down the drain as unused steam. Cooling water is injected into the steamer
12 drain line to condense the wasted steam before it is expelled to the main sewer line. This continuous flow of steam down the drain places a continuous demand on the boiler as cold water (to replenish the wasted steam) is added to the boiler. Connectionless steamers do not need the water and drain connections typically associated with steam cookers. Water is manually poured into a reservoir at the bottom of the cooking compartment at the beginning of each day and as needed. Heating elements inside or underneath the reservoir create steam by simply boiling the water, which then fills the compartment during the cooking process. Connectionless steamers are inherently more energy efficient than boiler-based or conventional steam-generator type steamers since any steam that does not condense on the food remains in the cooking compartment. Connectionless steamers typically exhibit cooking energy efficiencies that exceed 50% (ASTM full-load potato test). Figure 8-8 compares the cooking-energy efficiency for several types of electric pressureless steamers. Note that steamers numbered 4 through 12 are connectionless Cooking-Energy Efficiency Figure 8-8. Electric pressureless steamer cooking-energy efficiency Test Steamer Number
13 Steamer Energy Consumption Projected energy consumption for gas and electric steamers are presented in Table 8-2 and 8-3. Based on in-kitchen monitoring at the Pacific Gas and Electric Company Production-Test Kitchen in San Ramon, California, average energy consumption rates for steamers reflect a duty cycle of 15% for gas units and 20% for electric units Daily energy consumption for steamers was calculated by multiplying the median rated energy input for each steamer category by the respective duty cycle and the hours of operation. Duty cycle is defined as the average rate of energy consumption expressed as a percentage of the rated energy input or the peak rate at which an appliance can use energy. Typical operating hours were gleaned from in-kitchen energy-use monitoring experiences and observations as well as on the PREP study 23 and a proprietary end-use monitoring report. Projected annual energy consumption was determined by assuming a 6-day per week, 52-week per year operation. Table 8-2. Projected Energy Consumption for Gas Steamers. Nominal Size Rated Energy Input Duty Cycle Avg. Energy Consumption Typical Operating Hours Annual Energy Consumption (kbtu/h) (%) (kbtu/h) (h/d) a (kbtu) b PRESSURE: Boiler-Based 6 pan (Median) c ,000 PRESSURELESS: Boiler-Based 6 pan (Median) c ,000 a Operating hours or appliance "on time" is the total period of time that an appliance is operated from the time it is turned "on" to the time it is turned "off". b The annual energy consumption calculation is based on the average energy use rate x the typical operating hours x 6 days per week x 52 weeks per year. c The duty cycle is based on monitoring two gas convection steamers with input rates of 250 kbtu/h and 200 kbtu/h in a real-world production kitchen. An associated average energy consumption rate of 32 kbtu/h was calculated. 18,
14 Table 8-3. Projected Energy Consumption for Electric Steamers. Nominal Size Rated Energy Input Duty Cycle Avg. Energy Consumption Typical Operating Hours Annual Energy Consumption (kw) (%) (kw) (h/d) a (kwh) b (kbtu) c PRESSURE: Boiler-Based 6 pan (Median) d ,800 74,500 PRESSURELESS: Boiler-Based 6 pan (Median) d ,800 74,500 Connectionless 6 pan (Median) e ,920 37,300 a Operating hours or appliance "on time" is the total period of time that an appliance is operated from the time it is turned "on" to the time it is turned "off". b The annual energy consumption calculation is based on the average energy use rate x the typical operating hours x 6 days per week x 52 weeks per year. c Conversion Factor: 1kW = kbtu/h. d The duty cycle is based on monitoring two steamers in a real-world operation. 20,21 d The duty cycle for connectionless steamers is based on monitoring two steamers in a real-world operation. 22 A more robust energy model will be incorporated into subsequent revisions of the ASTM Test Method for the Performance of Steam Cookers (F1484). In this model, cooking energy use is broken down between heavy-and light-load conditions. Annual energy use is calculated based on preheat, idle, cooking energy rate, and production rate test results from applying ASTM F Ventilation Requirements Steamers are classified as light duty from the perspective of exhaust ventilation. For a sidewall-canopy hood, the design ventilation rate for steam equipment would range from 150 to 200 cfm (75 to 100 L/s) per linear foot of hood. Research and Development Pressureless steamers have a large energy performance bandwidth, due to the inherent inefficiency of traditional boiler-based models and the efficient selfcontained design of the new generation of connectionless steamers (Figure
15 8-7). Additionally, some of the electric connectionless steamers with high heavy-load cooking energy efficiencies demonstrate relatively high idle energy rates (steamer 10 in Figure 8-4). Since most steamers spend a significant amount of their operating time in idle, or stand-by mode, reducing idle losses would be a cost-effective way to reduce daily energy consumption. The option of a stand-by switch, where the temperature of the compartment idles below 212 F is one strategy. Increasing the level of insulation is another. While steamers are seldom used for cook-to-order in most food service operations, the shorter cook times associated with boiler-based models gives them a perceived advantage over their connectionless counterparts. One strategy for reducing connectionless steamer cook times is to add a fan that circulates the steam throughout the compartment. By adding a convection component, these manufacturers hope to not only increase the production capacity of their models, but also hope to improve the cooking uniformity. However, more development is needed in this area to optimize the design and truly compete with the boiler-based models. Manufacturers of compartment steamers have applied dramatic development efforts since the 1996 edition of this technology assessment, particularly in the area of electric counter-top models. However, there is distinct need for the development of gas-fired connectionless steamers that can raise the efficiency bar over conventional gas-fired boiler-based steamers. Industry Market Focus The latest generation of countertop-pressureless (atmospheric) steamers offer a significant improvement in energy efficiency and cooking performance, resulting in a lower operating cost. Pressureless steamers are available in compartment sizes ranging from 3 to 6 pans and may be stacked. There are currently two types of high-efficiency pressureless steamers: connectionless and steam-generator. With respect to the connectionless variety, the absence of water and drain connections makes installation simple and lowers maintenance costs. The compartment is simply drained at the end of the day no periodic de-liming is required. However, some connectionless steamers exhibit somewhat longer cook times than their steam-generator counterparts
16 New steam-generator designs employ more of a closed system, which strive to provide steam to the cavity only as it is needed. One advantage of steamgenerator type steamers is faster cook times and higher production rates although steamer cook times are seldom a critical-path issue for most commercial kitchens. The latest generation of steam-generator type steamers uses less water and offers lower idle energy rates than their predecessors, allowing them to reasonably compete with their connectionless counterparts (Steamer number 3 in Figure 8-7)
17 References 1. Avery, A.C., A Modern Guide to Foodservice Equipment. CBI Publishing Company, Inc. Boston. 2. American Society for Testing and Materials, Standard Test Method for the Performance of Steam Cookers. ASTM Designation F In annual book of ASTM Standards, West Conshohocken, PA. 3. Selden, M., Development and Validation of a Uniform Testing Procedure for Steam Cookers. Report , April. 4. Yap, D., Bell, T., Knapp, S., AccuTemp Steam n Hold, Model 208-D8-300 Electric Steamer Performance Test: Application of ASTM Test Method F Report , September. 5. Bell, T., Yap, D., Southbend Simple Steam, Model EZ-3 Electric Steamer Performance Test: Application of ASTM Test Method F Report , December. 6. Bell, T., Miner, S., Nickel, J., Zabrowski, D., Stellar Steam CAPELLA Electric Steamer Performance Test: Application of ASTM Test Method F Food Service Technology Report , January. 7. Bell, T., Miner, S., Vulcan VPX3 Electric Steamer Performance Test: Application of ASTM Test Method F Food Service Technology Center Report , May. 8. Bell, T., Miner, S., Vulcan VPX5 Electric Steamer Performance Test: Application of ASTM Test Method F Food Service Technology Center Report , May. 9. Knapp, S., Nickel, J., AccuTemp Steam n Hold, Model 208-D8-300 and 400 Electric Steamers In-Kitchen Appliance Performance. Report , October. 10. Bell, T., Nickel, J., Cleveland Range Inc., Electric Steamer Performance Test: Application of ASTM Test Method F Food Service Technology Center Report , November. 11. Bell, T., Miner, S., Nickel, J., Zabrowski, D., Market Forge, ET- 3E Electric Steamer Performance Test: Application of ASTM Test Method F Report , April. 12. Bell, T., Miner, S., Nickel, J., Zabrowski, D., Market Forge, ET- 5E Electric Steamer Performance Test: Application of ASTM Test Method F Report , April
18 13. Yap, D., Ardley, S., Groen HyperSteam, Model HY-3E Electric Steamer Performance Test: Application of ASTM Standard Test Method F Report , May. 14. Bell, T., Nickel, J., Market Forge STP-6E Electric Steamer Performance Test: Application of ASTM Test Method F Food Service Technology Center Report , December. 15. Bell, T., Nickel, J., Market Forge STP-6E Electric Steamer Performance Test: Application of ASTM Test Method F Food Service Technology Center Report , December. 16. Bell, T., Miner, S., Nickel, J., Zabrowski, D., Vulcan-Hart Gas Steamer Performance Test, Model VL2GSS (Pressure) and Model VS3616G (Atmospheric) Steamer Performance Test: Application of ASTM Test Method F Food Service Technology Report , December. 17. Bell, T., Miner, S., Nickel, J., Zabrowski, D., Vulcan-Hart Gas Steamer Performance Test, Model VHX24G-3 Steamer Performance Test: Application of ASTM Test Method F Food Service Technology Report , January. 18. Pieretti, G., Blessent, J., Kaufman, D., Nickel, J., Fisher, D., Cooking Appliance Performance Report - PG&E Production-Test Kitchen. Pacific Gas and Electric Company Department of Research and Development Report , May Cleveland Model 42-CKGM-250 Gas Pressureless Steamer: Appliance Performance in Production. Publication Pending. 20. Selden, M., Production-Test Kitchen Appliance Performance Report: Cleveland Electric Pressureless Steamer. Pacific Gas and Electric Department of Research and Development Report , June. 21. Cesio, C., Nickel, J., Conner, M., Groen Model HY-6E Hyper- Steam Electric Pressureless Steamer In-Kitchen Appliance Performance Report. Report , August. 22. Knapp, S., Nickel, J., Bell, T., AccuTemp Steam n Hold, Model 208-D8-300 and 400 Electric Steamers: In-Kitchen Appliance Performance Report. Report , December. 23. Claar, C.N., Mazzucchi, R.P., Heidell, J.A., The Project on Restaurant Energy Performance (PREP) End-Use Monitoring and Analysis. Prepared for the Office of Building Energy Research and Development, DOE, May. Information in this module also references Manufacturers Product Literature, catalogues, and appliance specification sheets
9 Steam Kettles. Introduction. Cooking Process
9 Steam Kettles Introduction Steam kettles are an improved, self-contained version of the large stockpot used for range top cooking. And they are put to many of the same tasks. Steam kettles are often
Southbend Simple Steam, Model EZ-3 Electric Steamer Performance Test
Southbend Simple Steam, Model EZ-3 Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.99.83 Food Service Technology Center Manager: Don Fisher Final Report,
Evaluating the Water Savings Potential of Commercial Connectionless Food Steamers. FINAL REPORT June 2005. Angelo Karas Victor Kong Don Fisher
Evaluating the Water Savings Potential of Commercial Connectionless Food Steamers FINAL REPORT June 2005 Prepared by: Angelo Karas Victor Kong Don Fisher Fisher-Nickel, inc. Food Service Technology Center
Case Studies in Restaurant Water Heating
Case Studies in Restaurant Water Heating Donald Fisher, Fisher-Nickel, Inc. William Pietrucha, Pacific Gas and Electric Company ABSTRACT This paper presents an overview of hot water use and the associated
5 Range Tops. Introduction
5 Range Tops Introduction Figure 5-1. Six-burner range top with range oven. It can be said that the commercial range top is the most widely used piece of commercial cooking equipment. In addition to being
Heating Water by Direct Steam Injection
Heating Water by Direct Steam Injection Producing hot water by direct steam injection provides a solution where large volumes of hot water at precise temperatures are required, and where energy and space
On-Site Energy Monitoring of a Two-Group Espresso Machine Special Report
On-Site Energy Monitoring of a Two-Group Espresso Machine Special Report FSTC Report 5011.00.91 Food Service Technology Center Manager: Don Fisher Final Report December 2000 Prepared by: Richard Young
Ice Machine Field Study: Energy and Water Saving with Ice Machine Upgrade and Load Shifting
Ice Machine Field Study: Energy and Water Saving with Ice Machine Upgrade and Load Shifting FSTC Report 501310087 Food Service Technology Center September 2011 Prepared by: Angelo Karas David Cowen Don
ENERGY EFFICIENCY ENERGY EFFICIENCY: Saving Dollars While Clearing the Air
: Saving Dollars While Clearing the Air After labor and food, energy is the largest controllable cost in a restaurant s operation. And energy is a great place to start in becoming a green restaurant because
Boiler Preparation, Start-Up and Shutdown
Boiler Preparation, Start-Up and Shutdown Learning Outcome When you complete this module you will be able to: Describe the basic preparation of a boiler for start-up, and the start-up and shutdown procedures.
Printing and Publishing Energy Savings Guide
Printing and Publishing Energy Savings Guide Oregon printing and publishing plants face challenges of rising operating costs, environmental and other regulations, outdated equipment and customer demand
A. GENERAL INFORMATION No. 33 (1) GUIDELINES FOR COMBI-OVENS
A. GENERAL INFORMATION No. 33 (1) GUIDELINES FOR COMBI-OVENS A combi-oven is a versatile piece of equipment that combines three modes of cooking in one oven: steam, circulated hot air or a combination
Effects of Ultra-High Turndown in Hydronic Boilers By Sean Lobdell and Brian Huibregtse January 2014
Effects of Ultra-High Turndown in Hydronic Boilers By Sean Lobdell and Brian Huibregtse January 2014 Today, hydronic boilers are producing greater efficiencies than previously thought possible, all due
Energy saving tips for home
Energy saving tips for home Contents 1 Heating and cooling 2 Computers, TVs and general appliances 4 Kitchen and cooking 6 Washing and drying 8 Lighting 9 Outdoors 9 We re all looking for ways to cut back
Energy Efficiency HOSPITALITY. www.energia.ie
Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real
Energy Saving Fact Sheet Boilers
Energy Saving Fact Sheet Boilers Turn a burning issue into real energy savings You need a boiler to heat your premises and provide hot water or to generate steam for use in industrial processes. Unfortunately,
USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book
USERS GUIDE LOGIC Heat 12, 15, 18, 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
SAVE ENERGY AT HOME INSULATE AND AIR SEAL
SAVE ENERGY AT HOME INSULATE AND AIR SEAL Check the roof insulation level and add insulation to maintain minimum R-38 (6 of blown cellulose or equal). Use R-19 between frame or R-10 rigid insulation for
Energy Efficient Operations and Maintenance Strategies for Boilers
Energy Efficient Operations and Maintenance Strategies for Boilers Large, complex and widely used, industrial boilers are major consumers of fuel. Proper operations and maintenance (O&M) procedures must
Thermal Coupling Of Cooling and Heating Systems
This article was published in ASHRAE Journal, February 2011. Copyright 2011 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Posted at www.ashrae.org. This article may not
Cooling system components, removing and installing
Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,
DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING
By Philip Sutter Pick Heaters, Inc. DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING INTRODUCTION Many process plants currently use steam or hot water to heat jacketed devices such as tanks,
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
By Donald Fisher, P.Eng., Associate Member ASHRAE
By Donald Fisher, P.Eng., Associate Member ASHRAE Decisions to purchase a commercial kitchen ventilation (CKV) system often are based on rule-of-thumb estimates using a $/cfm index (i.e., annual energy
Cooking A World of New Tastes
Cooking A World of New Tastes S E G M E N T 2 Cooking With Moist Heat Steaming Boiling Glazing Segment 2 Cooking With Moist Heat 19 S E G M E N T 2 Cooking With Moist Heat Learning Objectives Apply steaming
ENERGY COSTS A LOT, DON T WASTE IT. Professer. O.Courant SAVE UP TO 15% ON YOUR MONTHLY ELECTRICITY BILL. Konn servi lénerzi, ou ki pou sorti gagnan
ENERGY COSTS A LOT, DON T WASTE IT SAVE UP TO Konn servi lénerzi, ou ki pou sorti gagnan SAVE UP TO SOME HANDY TIPS TO SAVE ENERGY How to use energy efficiently at home and save money? Bad habits are hard
TIPS ON ENERGY SAVING
TIPS ON ENERGY SAVING IN HOME APPLIANCES AND ELECTRICITY SAFETY The Domestic Sector accounts for 30% of total energy consumption in the country. There is a tremendous scope to conserve energy by adopting
INSTALLATION & OPERATION MANUAL
INSTALLATION & OPERATION MANUAL GAS CONVECTION STEAMERS MODELS VSX5G, VSX5GC, VSX7GC & VSX10GC MODELS VSX 5G VSX5GC VSX7GC VSX10GC ML-114046 ML-114947 ML-114948 ML-114949 Model VSX10GC For additional information
Energy Efficiency. Bars & RestauRants. www.energia.ie
Energy Efficiency Bars & RestauRants www.energia.ie 2 Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could
Steam System Efficiency. Bill Lumsden Leidos Engineering
Steam System Efficiency Bill Lumsden Leidos Engineering Steam System Efficiency Steam System Efficiency Key Take-aways: Review of the properties of ice, water, and steam Learn the basics of steam trap
Heating oven with mechanical convection
FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous
A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN
A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN Application 1 The first step in selecting an industrial oven is defining the required heat application that your oven will be used for. Heat processing is extensively
Codes and High Performance Hot Water Systems. Gary Klein Affiliated International Management, LLC 916 549 7080 gary@aim4sustainability.
Codes and High Performance Hot Water Systems Gary Klein Affiliated International Management, LLC 916 549 7080 [email protected] Annual Energy Use for Heating Water Natural Gas Gallons Per Day
Case Studies: Infrared Heating in Industrial Applications
Case Studies: Infrared Heating in Industrial Applications Chao Chen, Puget Sound Energy ABSTRACT Puget Sound Energy (PSE) is a utility which serves more than one million electric customers and over 700,000
Water Efficiency. Water Management Options. Boilers. for Commercial, Industrial and Institutional Facilities. Boiler Water Impurities
Water Efficiency Water Management Options Boilers for Commercial, Industrial and Institutional Facilities Boiler Water Impurities All boiler make-up water contains impurities. As clean steam is released
Base Cabinet with Self-storing Folding Doors and Floor
Usable Kitchens When designing a kitchen for use by persons with mobility impairments, especially those who use wheelchairs, careful layout of the kitchen is crucial to maintaining accessibility. People
STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE
Page 1 of 9 PURPOSE Steam is the most commonly used heating medium for maintaining process temperatures. Compared to other heating media, steam contains a significant amount of heat energy, and this heat
Sample Customer 123 Conservation Way TAMPA FL 33626 Tracking Number: 000675309
Thank you for completing the Online Home Energy Audit. Based on the answers that you provided in the questionnaire, the following is a complete analysis of your household's energy consumption. We have
Small Business Energy Efficiency and Specialty Equipment
Small Business Energy Efficiency and Specialty Equipment Scott Schultz, LEED AP, CEM Energy Program Engineer, SAIC, an Ameren Illinois ActOnEnergy Partner August 28, 2013 Practical Items If you can't hear
SWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
Operating instructions
Operating instructions Gas condensing boilers MGK-130 MGK-170 MGK-210 MGK-250 MGK-300 Wolf GmbH Postfach 1380 D-84048 Mainburg Tel. +49 8751/74-0 Fax +49 8751/741600 Internet: www.wolf-heiztechnik.de Document
High-efficient gas boiler CompactGas
High-efficient gas boiler CompactGas Patented alufer for a high efficiency and low emission. 1 CompactGas (1000-2800). Advantages at a glance. The Hoval CompactGas fulfils all expectations with regard
SUPER WAVE OVEN. ROASTS, BAKES, BROILS, AIR FRIES, GRILLS, BOILS & STEAMS 1300 Watt Power/12.5 Quart
SUPER WAVE OVEN ROASTS, BAKES, BROILS, AIR FRIES, GRILLS, BOILS & STEAMS 1300 Watt Power/12.5 Quart Customer Service: 1-800-423-4248 Printed in China Super Wave Oven ITEM NO.8217SI. The Sharper Image name
Convection TCO600. For your safety and continued enjoyment of this product, always read the instruction book carefully before using.
Convection Toaster Oven TCO600 For your safety and continued enjoyment of this product, always read the instruction book carefully before using. IMPORTANT SAFEGUARDS SAVE AND READ THESE INSTRUCTIONS When
GAS HEATING IN COMMERCIAL PREMISES
ENERGY EFFICIENCY OFFICES GAS HEATING IN COMMERCIAL PREMISES www.energia.ie www.energia.ie Typically, energy reductions of 10% or more can be made easily through maintenance and low cost improvements.
8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en
8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................
ENERGY SAVING TIPS IN DOMESTIC SECTOR
ENERGY SAVING TIPS IN DOMESTIC SECTOR LIGHTING SYSTEM 1. One of the best energy-saving devices in the light switch. Turn off lights when not required. 2. Fluorescent tube lights and CFLs convert electricity
THE CASE FOR A REFRIGERATION PREVENTATIVE MAINTENACE PROGRAM
THE CASE FOR A REFRIGERATION PREVENTATIVE MAINTENACE PROGRAM Prepared and Presented By: Don Langston President & CEO, Aire Rite Air Conditioning & Refrigeration Inc Setting the Foundation The Refrigeration
HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS
HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS William K. Scullion, Application Engineering Leader, MEGTEC Systems, De Pere, WI Introduction Competitive pressures continuously motivate us to examine our
Hot Water Heating: Technologies and Use
Hot Water Heating: Technologies and Use Skip Hayden Integrated Energy Systems CanmetENERGY Better Buildings by Design 2010 Burlington Vermont February 2010 Natural Resources Canada Ressources naturelles
Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now
Fact Sheet #6 Air Conditioning In this fact sheet you will discover: The opportunity for energy efficiency How air conditioning works Low cost actions to reduce energy usage now Investments to reduce costs
Description of functions
Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the
The recipe for a wattsmart restaurant
The recipe for a wattsmart restaurant Based on the ENERGY STAR Guide for Restaurants: Putting Energy Into Profit ENERGY STAR, a U.S. Environmental Protection Agency program, helps us all save money and
Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard
Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Introduction SRU s (Sulfur Recovery Units) are critical pieces of equipment in refineries and gas plants. SRUs remove sulfur compounds from certain
Food Production Methods
Food Production Methods Module- 28 Lec- 28 Dr. ShishirSinha Dept. of Chemical Engineering IIT Roorkee Objectives Describe the goal of production for foodservice operation Describe the obstacles to the
ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user
For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents
Middleby Marshall, Model PS570 Conveyor Oven Performance Test
Middleby Marshall, Model PS570 Conveyor Oven Performance Test Application of ASTM Standard Test Method F 1817-97 CKVL Report 0011107 April 2003 Prepared by: Rich Swierczyna Paul Sobiski Architectural Energy
Natural Gas Energy Efficiency Opportunities for Commercial & Industrial Customers. Michael Pace Lead Engineer C & I Efficiency Programs
Natural Gas Energy Efficiency Opportunities for Commercial & Industrial Customers Michael Pace Lead Engineer C & I Efficiency Programs Agenda Energy Efficiency Opportunities for Small/Mid Commercial Facilities
Managing Heat Stress in Poultry
Managing Heat Stress in Poultry Amy E. Halls, Monogastric Nutritionist Shur-Gain, Nutreco Canada Inc. Heat stress has several serious and economical effects on poultry. In broilers and turkeys, it can
Increasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas
Increasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas Mark Schiffhauer, ATSI Engineering Services Cameron Veitch, Combustion and Energy Systems Scott Larsen, New York State Energy
MODELS GAS AVAILABLE. Combi ovens for catering
GAS MODELS AVAILABLE Combi ovens for catering The new range of products from Rapid, available also as gas heated models, features the highest technology for heating thanks to pre-mixed air blown burners.
Energy Efficiency in Steam Systems
Energy Efficiency in Steam Systems Fundamentals of Energy Efficiency: An Introductory Workshop April 2008 John S. Raschko, Ph.D. Mass. Office of Technical Assistance www.mass.gov/envir/ota (617) 626-1093
Baxi Combi 80e & 105e
Baxi Combi 8e & 15e Please keep these instructions safe. Should you move house, please hand them over to the next occupier. Gas Fired Wall Mounted Combination Boiler User s Operating Instructions Natural
RESEARCH HIGHLIGHT. The Impact of Heat Pump Water Heaters on Whole-House Energy Consumption
RESEARCH HIGHLIGHT December 2014 Technical Series 14-104 The Impact of Heat Pump Water Heaters on Whole-House Energy Consumption INTRODUCTION Heat pump water heaters are one of the most energyefficient
Rusty Walker, Corporate Trainer Hill PHOENIX
Refrigeration 101 Rusty Walker, Corporate Trainer Hill PHOENIX Compressor Basic Refrigeration Cycle Evaporator Condenser / Receiver Expansion Device Vapor Compression Cycle Cooling by the removal of heat
Example Retrocommissioning Measure: Opening Throttled Discharge Valves
Opening Throttled Discharge Valves This 21-story building, constructed in 1997, is located in Oregon and contains 589,000 gross square feet of mostly office occupancy. The HVAC system includes six large
USER MANUAL Two Tier Steamer Model: 16145 Helpline No: 015394 88100
Lakeland Alexandra Buildings, Windermere, Cumbria LA23 1BQ Tel: 015394 88100 Web: www.lakeland.co.uk USER MANUAL Two Tier Steamer Model: 16145 Helpline No: 015394 88100 INTRODUCTION Thank you for choosing
Some Criteria for Choosing a Steam Boiler for a Microbrewery
Some Criteria for Choosing a Steam Boiler for a Microbrewery Jack Coe Rite Engineering and Manufacturing Corporation Breweries rely on steam heating for a number of functions, primarily to heat the brew
L_PTL12_C01_E_P_TOKIOK_L_PTL12_C01_E_P_TOKIOK 01.08.11 11:50 Seite 17. Leonard Hausgeräte 2012 Leonard domestic appliances 2012
L_PTL12_C01_E_P_TOKIOK_L_PTL12_C01_E_P_TOKIOK 01.08.11 11:50 Seite 17 Leonard Hausgeräte 2012 Leonard domestic appliances 2012 Vorlage Druck QMI L_PTL12_C01_E_P_TOKIOK_L_PTL12_C01_E_P_TOKIOK 01.08.11 11:50
Heating oven with mechanical control
ED series 53 Drying ovens / Heating ovens Heating oven with mechanical control The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C (572 F). Thanks
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression
Response: The combi boiler. Response: The fit anywhere combi
Response: The combi boiler The Ideal Response is a wall mounted, fanned flue combination boiler which serves a home's central heating system and delivers hot water on demand. It has been designed to be
ELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
The Different Types of Air Conditioning Equipment for IT Environments
The Different Types of Air Conditioning Equipment for IT Environments By Tony Evans White Paper #59 Executive Summary Cooling equipment for an IT environment can be implemented in 10 basic configurations.
Cooking at the Speed of light!
Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide
Recover Heat from Boiler Blowdown Water
Prepared for California Energy Commission (CEC) Prepared By: Southern California Gas Company (A Sempra Energy Utility) E3M Inc. May 2012 i Disclaimer The CEC and its contractor, Southern California Gas
With the background of fulfilling public commitments for ECONO-PILOT ENERGY-SAVING SYSTEM FOR WATER PUMPS
ECONO-PILOT ENERGY-SAVING SYSTEM FOR WATER PUMPS SAWAI Tsuneji *1 TAKAHASHI Hiroshi *1 INOUE Ken-ichi *2 We have developed the Econo-Pilot energy-saving system for water pumps, which reduces the power
Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669
Report Date: 04/03/2014 Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669 About this Advisory Report Energy use in our homes is responsible for almost
Integrated Solar Radiant Systems
Integrated Solar Radiant Systems William Shady PE President Topics Radiant heating Indoor air quality Radiant Cooling Project Photos Questions and answers The goal for our clients Healthy Comfort Why Radiant
Use and Care Instructions Dual Gas Steam Generator & Convection Steamer
Use and Care Instructions Dual Gas Steam Generator & Convection Steamer 24CGA10.2 24CGA6.2 Series: Gemini Model Nos. 24CGA6.2, 24CGA10.2 1333 East 179 th Street Cleveland, Ohio 44110 Phone: (216) 481-4900
Vacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
5.2. Vaporizers - Types and Usage
5.2. Vaporizers - Types and Usage 5.2.1. General Vaporizers are constructed in numerous designs and operated in many modes. Depending upon the service application the design, construction, inspection,
Analysis of Energy Consumption. ACME Limited
Analysis of Energy Consumption at ACME Limited by A.N. Energy Consultancy A report written using the BizEE Benchmark energy auditing software package developed by BizEE Software Ltd www.bizeesoftware.com
High Capacity Hot Air Dryer
High Capacity Hot Air Dryer MADE IN AUSTRIA autumn 2015 www.zimmer-austria.com page 1 Hot air dryer type: Compact HC The modular construction of the high efficiency and powerful hot air nozzle dryer is
Laddomat 21-60 Charging unit
Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the
That s it, that s what we do: air knife drying. Ray Ralph, President R.E. Morrison Equipment Inc.
Post Shrink Tunnel Drying Air Knife Belt Cleaning Systems Conveyorized Drying Systems Bolt-On Air Knife Systems Air Knife Belt Defrosters Crate and Tote Drying Booster Blowers Vacuum Pumps for Carton Erecting
Draining and filling cooling system
Page 1 of 9 Draining and filling cooling system Special tools and workshop equipment required Adapter -V.A.G 1274/8- Pipe -V.A.G 1274/10- Drip tray -V.A.G 1306- or drip tray for workshop hoist -VAS 6208-
Technical data. Danfoss DHP-A
Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs
M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A
Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000
Frequently Asked Questions
Frequently Asked Questions System and Valve Basics: 1. Q: What is good cooling coil performance? A: The temperature range is controlled within +/- 0.5 F (0.28 C) off the cooling coil at set point or below.
Zip Hydroboil Plus Cuts energy consumption dramatically
Instant Boiling Water Zip Hydroboil Plus Cuts energy consumption dramatically Extended Range Zip is the clear UK market leader in instant boiling water systems with our products in daily use in tens of
INSTRUCTION MANUAL. Boil-Out TABLE OF CONTENTS SAFETY WARNINGS 2-3 RESPONSIBILITY 3 INTRODUCTION 3 PRE-BOIL OUT PROCEDURES 3-5 BOIL OUT PROCESS 5-9
TABLE OF CONTENTS Description Page Number SAFETY WARNINGS 2-3 RESPONSIBILITY 3 INTRODUCTION 3 PRE-BOIL OUT PROCEDURES 3-5 BOIL OUT PROCESS 5-9 Indeck Keystone Energy, LLC. 5451 Merwin Lane, Suite 100 Erie,