NORSOK STANDARD COMMON REQUIREMENTS MECHANICAL COMPLETION AND COMMISSIONING
|
|
|
- Adrian Griffin
- 9 years ago
- Views:
Transcription
1 NORSOK STANDARD COMMON REQUIREMENTS MECHANICAL COMPLETION AND COMMISSIONING Rev. 1, May 1996
2 Rev. 1, May 1996 CONTENTS 1 FOREWORD 2 2 SCOPE 2 3 NORMATIVE REFERENCES 2 4 DEFINITIONS AND ABBREVIATIONS Definitions Abbreviations 4 5 COMPLETION PRINCIPLES Overall goal Completion phases Responsibilities Common requirements Documentation Project Completion System (PCS) Planning 6 6 MECHANICAL COMPLETION Introduction Documentation for a MC Package Handover at Mechanical completion Carry Over Work Register (COWR) Typical Mechanical completion activities 7 7 COMMISSIONING Introduction Typical commissioning preparation activities Commissioning procedure content Commissioning documentation and handover to operation 10 ANNEX A MECHANICAL COMPLETION DOCUMENTATION 11 ANNEX B COMMISSIONING DOCUMENTATION 21 NORSOK standard Page 1 of 26
3 Rev. 1, May FOREWORD NORSOK (The competitive standing of the Norwegian offshore sector) is the industry initiative to add value, reduce cost and lead time and remove unnecessary activities in offshore field developments and operations. The NORSOK standards are developed by the Norwegian petroleum industry as a part of the NORSOK initiative and are jointly issued by OLF (The Norwegian Oil Industry Association) and TBL (The Federation of Norwegian Engineering Industries). NORSOK standards are administered by NTS (Norwegian Technology Standards Institution). The purpose of this industry standard is to replace the individual oil company specifications for use in existing and future petroleum industry developments, subject to the individual company's review and application. The NORSOK standards make extensive references to international standards. Where relevant, the contents of this standard will be used to provide input to the international standardisation process. Subject to implementation into international standards, this NORSOK standard will be withdrawn. 2 SCOPE This standard defines the principles and structure of Mechanical completion and commissioning. 3 NORMATIVE REFERENCES ISO 9000 series standards 4 DEFINITIONS AND ABBREVIATIONS 4.1 Definitions Normative references Informative references Shall Should May Can Project Completion System (PCS) Shall mean normative in the application of NORSOK standards. Shall mean informative in the application of NORSOK standards. Shall is an absolute requirement which shall be followed strictly in order to conform with the standard. Should is a recommendation. Alternative solutions having the same functionality and quality are acceptable. May indicates a course of action that is permissible within the limits of the standard (a permission). Requirements are conditional and indicates a possibility open to the user of the standard. Is a computerised system for electronic documentation of Mechanical completion, commissioning and preservation by system, subsystem, area, commissioning package, MC package and/or individual tag. NORSOK standard Page 2 of 26
4 Rev. 1, May 1996 System Mechanical Completion Status Index (MCSI) Subsystem Commissioning Package MC Package Commissioning (C) Mechanical Completion (MC) Preservation Factory Acceptance Test (FAT) Mechanical Completion Certificate (MCC) Mechanical Completion Check Record (MCCR) Punch List (PL) Status "OK" Status "NA" Status "PA" Status "PB" Punch List Register (PLR) Carry Over Work Register An operational system or a non-operational system. Operational systems are dynamic process, utility or facility systems such as sea water, diesel, HVAC, telecom, main power and control system Non-operational systems are systems such as surface protection, insulation, civil, structural steel, markings and signs, cable and tubing trays. This is a listing of all items/tags with associated check record status for each MC (or commissioning) package. The MCSI should be produced from the EDP based Project completion system. A system broken down into functional subsystems. A practical scope of work unit within a system or subsystem for commissioning, constituting a functional unit which can be tested by commissioning to confirm its suitability for operation. A practical unit of the scope of work for one discipline within a commissioning package. Is the functional verification of equipment and facilities that are grouped together in systems. The checking and testing of equipment and construction to confirm that the installation is in accordance with drawings and specifications and ready for commissioning in a safe manner and in compliance with project requirements. The preventive maintenance carried out on equipment before it is taken into use. Testing to be performed at suppliers workshop to verify the equipment's performance/functionality. A MC Certificate issued by the Executor to document that his MC scope has been carried out. The MC Certificates shall be used per MC package. A discipline checklist for the various equipment. These records form the basis of the MC documentation. MC Check Records are prepared for one or more items for recording of the results from checking and testing performed during MC. A Punch List describes incomplete work or malfunction of equipment or construction. This status means that this item is cleared and there is no further work associated with this item. This status means that the check is not applicable to the item referenced in the Check Record (CR). The item may however be applicable for subsequent executors. This means that this check item is not completed, and that remaining work is category 'A', i.e. must be completed prior to commissioning. This means that this check item is not completed and that remaining work is category 'B', i.e. may be completed prior to or after commissioning. A punch list register is a listing of all punch list items, prepared at a time when installation, functions or activities should have been completed. A register where incomplete items are documented sufficiently for NORSOK standard Page 3 of 26
5 Rev. 1, May 1996 (COWR) MC dossier Commissioning dossier Executor work preparation and completion. The COWR is based on the Punch Lists Register and describes punch listed work to be transferred to the next project executor. MC documentation compiled in MC package. Commissioning documentation compiled in Commissioning dossier. An organisation, supplier, contractor that performs a predefined scope of work. 4.2 Abbreviations C Commissioning COWR Carry Over Work Register CR Check Record FAT Factory Acceptance Test MC Mechanical Completion MCC Mechanical Completion Certificate MCCR Mechanical Completion Check Record (MCCR) MCSI Mechanical Completion Status Index MSL Material Status List PCS Project Completion System PL Punch List PLR Punch List Register RFCC Ready for Commisioning Certificate 5 COMPLETION PRINCIPLES 5.1 Overall goal The overall goal of Mechanical completion and commissioning is to verify that the system is designed and built to fulfil its purpose and specified requirements. The completion execution and documentation shall have as a goal to fulfil "NPD" rules as given in "Regulations for production and auxiliary systems". Life cycle cost principles and safety should govern all decisions and actions. Early establishment of commissioning packages is essential for an orderly and effective project completion. The commissioning plan shall have maximum priority to enable reversed planning in all project phases. All fabrication and installation planning shall be system oriented. Mechanical completion, commissioning, FAT, Preservation and suppliers assistance requirements shall be specified in the purchase orders. Repeating of MC/C checks performed at suppliers and assembly sites should be avoided, wherever possible. 5.2 Completion phases Definition phase In this phase the following is carried out: Completion philosophy. NORSOK standard Page 4 of 26
6 Rev. 1, May 1996 Coding structure and system breakdown. Completion requirements to suppliers and contractors Engineering phase In this phase the following is carried out: Commissioning Package & MC Package definition. Define commissioning network. Produce commissioning procedures Suppliers completion phase Equipment suppliers shall execute MC, FAT and commissioning and preservation as specified in the purchase order. The completion shall be documented as part of the completion system which leads up to handover to the company/client Construction/assembly Phase Executor shall perform MC and commissioning and preservation as specified in purchase order/contract documents. The completion is documented as part of the completion system which leads up to handover to the company. 5.3 Responsibilities Responsibilities are defined in the contract. MC execution and registration/documentation, shall be performed by anyone who has a scope of work to be performed, such as equipment suppliers, fabrication contractors, installation contractor and hook-up contractors. Commissioning registration and documentation shall be performed by anyone who has this responsibility implemented in their scope of work. 5.4 Common requirements This standard shall be used as a basis for preparing plans, procedures and documentation for Mechanical completion and commissioning. The implementation of this standard requires the use of a coding system for item and system numbering, e.g. NORSOK Z-DP-002, Coding system. 5.5 Documentation Mechanical completion documentation shall be completed/executed per item/mc package. Commissioning documentation shall be documented on a commissioning package level. All check/test records shall end up in a status OK-PA-PB. NORSOK standard Page 5 of 26
7 Rev. 1, May Project Completion System (PCS) An electronic based system for administration of Mechanical completion, commissioning and Punch List Register, should be used. 5.7 Planning All MC activities shall be planned on fully integrated fabrication, Mechanical completion and commissioning schedules on system prioritised basis in order to meet the optimal sequence of completion. 6 MECHANICAL COMPLETION 6.1 Introduction This chapter forms the basis for the execution and documentation of mechanical activities. Mechanical completion takes place through all phases of the project, starting at equipment supplier and continuing through fabrication up to commissioning phase. Mechanical completion encompasses all disciplines. The detailed responsibilities are described in the contract. Executor of MC activities is responsible for establishing and compiling the MC dossiers and report status into PCS. 6.2 Documentation for a MC Package The MC package shall consist of an MC Certificate, a MC Status Index and a Punch List Register printout as described below. A Mechanical Completion Certificate (MCC) is a form completed by the Executor after all MC is carried out. The MCC is the cover sheet for each MC package. A MC package shall when signed be ready for start of commissioning. The Check Records (CR) are the forms on which the Executors record the results of all checks, inspections and tests carried out for each individual item. A Punch List Register (PLR) shall be prepared by the Executor along with the MC activity. In each MC package a printout from the PLR shall be included to document the incompleted work. A MC Status Index (MCSI) listing the status of all CRs for the completed MC package shall be included in the MC documentation dossier. 6.3 Handover at Mechanical completion Handover at Mechanical completion to commissioning shall be at commissioning package level, documented by the Ready for Commissioning Certificate (RFCC). 6.4 Carry Over Work Register (COWR) The Carry Over Work Register lists all punch items that the Project accepts as cannot be completed during present phase. The COWR is used for the release of the work from the Executor and will as such be an input to the scheduling and planning of outstanding work to be performed during later phases. NORSOK standard Page 6 of 26
8 Rev. 1, May 1996 The COWR Item Number and cross reference to the Punch List Register/Check Records shall be given. COWR work shall be marked up on drawings or sketches and be included in the records. COWR Material Status List (MSL) and marked up drawings/instruction shall contain sufficient information for job setting in a later phase. 6.5 Typical Mechanical completion activities Mechanical completion activities includes checking of fabrication and installation work. Executor shall complete packages related to listed disciplines and as required by the MCSI. Executor shall complete the check list items as per the MCCR's. The activities shall include but not be limited to: (see also Annex A for typical check records) Mechanical Visual inspection for complete and correct installation. Internal inspection of tanks and vessels. Alignment. Load testing of lifting equipment. Hot oil flushing. Bolt tensioning. Dimension control. Preservation Electrical Visual inspection for complete and correct installation. Insulation and continuity testing of cables. Insulation testing of generator, transformers and motors, panels, distribution board etc. Earthing checks. Static check of switches and control devices. Battery preparations. Lighting and socket outlet checks. Area completion. Heat tracing. Preservation Instrument/Telecommunication Calibration and testing of instruments prior to installation. Visual inspection for complete and correct installation. Insulation and continuity testing of cables. Cleaning, flushing, pressure and leak testing of pneumatic and hydraulic tubing. Adjustment of control, alarm and shutdown settings. Loop testing. Function testing of control systems. Function testing of field instruments. Hot oil flushing of instrument tubing. Area completion. NORSOK standard Page 7 of 26
9 Rev. 1, May 1996 Preservation Piping NDE carried out. Welding procedures. Removal of all items subject to damage during flushing, cleaning and pressure testing. Flushing of pipework. Chemical cleaning and testing of pipework. Drying of tested pipework. Preservation of tested pipework. Reinstatement of all items after testing. Final inspection of pipework. Test ISO's and P&ID's showing the extent of each pressure test. Pneumatic and hydraulic tubing. Hot oil flushing of pipework. Bolt tensioning. Pipe supports completed. Insulation. Flow coding HVAC Visual inspection for complete and correct installation. Cleaning of ductwork. Leak testing of ductwork. Alignment checks. Mechanical functions checks of equipment. Preservation. Flow coding Safety Visual inspection for complete and correct installation. Preservation. Area completion Mechanical completion of non-operational systems Mechanical completion of non-operational systems includes completion status and checks on an area basis. Disciplines included structural, surface protection, insulation, fireproofing and architectural Structural Visual inspection for complete and correct installation. QC documentation. NDE carried out. Welding. Load testing of lifting lugs and monorails. NORSOK standard Page 8 of 26
10 Rev. 1, May Surface protection, Insulation and Fire proofing Visual inspection for complete and correct application. Thickness checks carried out. Adhesion checks carried out. Preservation. Insulation. Painting. Fire proofing Architectural Visual inspection for complete and correct installation. Preservation. Doors. 7 COMMISSIONING 7.1 Introduction This chapter forms the basis for preparation and execution of commissioning. Commissioning take place when Mechanical completion is completed for a system or part of a system. Commissioning can be divided into three main activities: Commissioning preparation Commissioning execution Commissioning documentation and handover to operation Establishment of a commissioning network and definition of commissioning packages early in a Project in order to establish fabrication/installation priorities and milestones. Definition of commissioning of part systems is essential in order to achieve an early commissioning completion. 7.2 Typical commissioning preparation activities The preparatory work shall consist of activities such as: Development of commissioning organisation Development of system breakdown (partsystem) Commissioning packages definition Commissioning schedules Commissioning budget including spare parts for commissioning Commissioning preparation check record (ref. Annex B for typicals) 7.3 Commissioning procedure content Commissioning shall be executed by guidance of a detailed procedure describing: Objective Details the operating parameters to be achieved. NORSOK standard Page 9 of 26
11 Rev. 1, May Description Shall contain a brief description of the system/partsystems to be commissioned, including marked up P&ID as a basis for all functions to be tested Lists of temporary equipment and consumables Lists all consumables, temporary equipment tools and requirements for suppliers assistance Health/Environment/Safety A list of all toxic and polluting fluids and materials shall be made, describing their handling and disposal. A check list of all required safety precautions including requirements for work permit shall be made. Prior to energization of electrical equipment a livening up notice shall be issued in order to inform all involved parties of forthcoming energising Preservation Requirements for removal of existing preservatives/protection shall be made and subsequent new preservation of the system if the system shall be out of operation for a period Scope The scope shall detail the work to be done step by step including the commissioning preparation, check record (ref. Annex B). Irregularities and/or faults shall be logged. Equipment suppliers start-up procedures shall be incorporated. Performance parameters shall be included for comparison of results with actual result achieved during commissioning Planning Detailed commissioning plans for system/part system shall be worked out and shall include manhours per discipline, including supplier assistance man-hours Handover The handover shall contain a certificate and other documents agreed with operation. 7.4 Commissioning documentation and handover to operation Handover of systems from Executor to project/operation shall be according to a formal procedure which as a minimum should consist of: Completion acceptance certificate (signed by both parties). Commissioning P&ID showing the extent of the completed system. Authority certificates (if any). Operational procedures and handbooks. NORSOK standard Page 10 of 26
12 Annex A Rev. 1, May 1996 ANNEX A CONTENTS MECHANICAL COMPLETION DOCUMENTATION (TYPICALS) (INFORMATIVE) Documentation for a MC package...15 MC certificate (MCC)...16 Piping completion status...17 MC check record - Instrument installation and inspection...18 MC check record - Electrical motors...19 MC check record - Centrifugals/schrewpump, compressor and hydr.motor...20 Punch list...21 MC documentation for a Commissioning package...22 Ready for commissioning certificate (RFCC)...23 NORSOK standard Page 11 of 26
13 Annex A Rev. 1, May 1996 Documentation for a MC - Package Punch List MCCR MCSI MCC for MC - Pack Mechanical Completion Certificate (MCC): States that all discipline related inspections and tests for a MC package have been carried out according to relevant contract documents. Mechanical Completion Status Index (MCSI): A Computerised listing of all Tag/Cable/Test/MCCR in a MC Pack, which gives MC scope of work and status for a completed package. Mechanical Completion Check Record (MCCR): Discipline checklist for the various equipment. These records form the basis of the MC - documentation. MC Punch List (PL): Is the form on which the supplier and contractor record any outstanding work. NORSOK standard Page 12 of 26
14 Annex A Rev. 1, May 1996 MC CERTIFICATE MCC (Rev. 1, May 1996) <Project> MC Package No. MCC Description : MCC Area : MCC Site : Comm. Package No. System : Sub System : SCOPE OF ACCEPTANCE Discipline code: Mechanical Complete as per attached MCSI MCC status: Date: It is hereby certified that the plant/equipment referenced has been inspected, tested and accepted in accordance with the attached MC check Records and other documents, but with the exception of outstanding word according to attached Punch List register. COMMENTS: VERIFIED SUPPLIER FABRICATION HOOK-UP Name Sign Date Name Sign Date NORSOK standard Page 13 of 26
15 Annex A Rev. 1, May 1996 DESIGN PRESS. (bar) TEST PRESS. (bar) PIPING COMPLETION STATUS PIPING COMPLETION STATUS (Rev. 1, May 1996) Sheet No. System Tag No. MC Package No. Subsystem Comm. Package No. <Project> PIPES EARTHING FLUSHED PRESSURE CHEMICAL PRESERVED VIDEO HOT OIL SUPPORTED GRP.PIPES TESTED CLEANED INSPECTION FLUSHED NDE CLEARED RE- INSTALLED ISO No. Spool No. Area Line No. P&ID No. Remarks It is hereby certified that the plant/equipment referenced has been inspected, tested and accepted in accordance with the attached acceptable records and other documents, but with the exception of the outstanding work according to attached punch list register. VERIFIED SUPPLIER FABRICATION HOOK-UP Name Sign Date Name Sign Date NORSOK standard Page 14 of 26
16 Annex A Rev. 1, May 1996 MC CHECK RECORD INSTRUMENT INSTALLATION AND INSPECTION (Rev. 1, May 1996) Sheet No. Tag No. : MC Package No. Description : Area : PO No. : System : Comm.Package No. Manufacturer : Subsystem : <Project> INSTALLATION CHECK SUPPL. FABR. HOOK-UP Punchlist item No. 01 Check instrument against data sheet 02 Check CE marking 03 Check calibration certificate 04 Installation check 05 Leakage test 06 Flushing carried out COMMENTS: VERIFIED SUPPLIER FABRICATION HOOK-UP Name Sign Date Name Sign Date NORSOK standard Page 15 of 26
17 Annex A Rev. 1, May 1996 MC CHECK RECORD ELECTRICAL MOTORS (Rev. 1, May 1996) Sheet No. Tag No. : MC Package No. Description : Area : PO No. : System : Comm.Package No. Manufacturer : Subsystem : <Project> EQUIPMENT INSPECTION, DE-ENERGISED STATE Check for no voltage and proper earthing applied 01 Check nameplate data and (ex)-markings against data sheet 02 Check CE-marking 03 No mechanical damage 04 No fluid leaks 05 Nuts and bolts tight 06 Terminal boxes and glanding correct 07 All labelling and warning marks correct 08 Internal earthing correct and securely tight 09 All internal cabling and aux. wiring neat and healthy 10 Heaters correctly installed 11 Check motor insulation resistance. Record lowest reading (MOHM): 12 Check bearing lubrication 13 Check free rotation with driven equip. uncoupled 14 Check cooling system, dust and debris removed 15 Communication arrangement and brushes correct (DC only) 16 Motor preservation correct 17 Push button station: a) Property supported b) No mechanical damage c) Labelling & identification correct 18 Preservation carried out. SUPPL. FABR. HOOK-UP Punchlist item No. COMMENTS: VERIFIED SUPPLIER FABRICATION HOOK-UP Name Sign Date Name Sign Date NORSOK standard Page 16 of 26
18 Annex A Rev. 1, May 1996 MC CHECK RECORD CENTRIFUGAL, SCHREWPUMP, COMPRESSOR AND HYDR.MOTOR (Rev. 1, May 1996) Sheet No. Tag No. : MC Package No. Description : Area : PO No. : System : Comm.Package No. Manufacturer : Subsystem : <Project> 01 Dataplate complies with data sheet 02 Check CE-marking 03 Skid installation correct 04 Dowels fitted in pump feet 05 Alignment Jack screws fit for driver 06 Correct shimspack for driver fitted 07 Alignment checked, see procedure 08 Jack screws retracted after alignment 09 Transmission checked 10 Coupling guard checked 11 Lubricant or preservation oil filled 12 Constant oiler removed 13 Grease nipples fitted 14 Gland packing fitted 15 Gland cooling fitted 16 Mechanical seal fitted 17 Pumpcase drain valve installed 18 Pumpcase vent valve installed 19 Drain line from skid pan installed 20 Inlet/Outlet checked 21 Skid mounted valves checked 22 Paintwork completed 23 NDE carried out 24 Material certificate checked 25 Pressure test carried out COMMENTS: INSPECTION ITEM SUPPL. FABR. HOOK-UP Punchlist item No. VERIFIED SUPPLIER FABRICATION HOOK-UP Name Sign Date Name Sign Date NORSOK standard Page 17 of 26
19 Annex A Rev. 1, May 1996 PUNCH LIST DISCIPLINE (Rev. 1, May 1996) Package Description : Area : MC Package No. <Project> PO No. : System : Comm.Package No. Manufacturer : Subsystem : Status A: Must be completed prior to milestone Status B: Can be left to a later stage, If appr. by Company Page of CLEARED BY (INIT.) DESCRIPTION (TAG NUMBER, DRAWING OR DOCUMENT REF.) VERIFIED SUPPLIER FABRICATION HOOK-UP Name Sign Date Name Sign Date NORSOK standard Page 18 of 26
20 Annex A Rev. 1, May 1996 MC Documentation for an Commissioning-Package Punch List Register MCSI RFCC for Commissioning Package No. From : Executor Accep. : Commissioning Ready for Commissioning Certificate (RFCC): Formal document for transfer a Commissioning Package from MC Executor to Commissioning. Mechanical Completion Status Index (MCSI): A Computerised listing of all Tag/Cable/Test(MCCR) with status for the completed package. MC Punch List Register: Is the form which describes any incomplete work per MC package. NORSOK standard Page 19 of 26
21 Annex A Rev. 1, May 1996 READY FOR COMMISSIONING CERTIFICATE RFCC (Rev. 1, May 1996) <Project> System : Subsystem : Commissioning Package No. : Commissioning Package Description : Mechanical completed as per attachment : - MCSI - Punch List Register - Preservation Status Site: RFCC Status: Status verified by executor Block letters: Signature: Date: Yes No Punch list items Comments: Accepted ready for Commissioning by Com.responsible Block letters: Signature: Date: NORSOK standard Page 20 of 26
22 Annex B Rev. 1, May 1996 ANNEX B COMMISSIONING DOCUMENTATION (TYPICALS) (INFORMATIVE) CONTENTS Commissioning preparation check record - Electrical equipment...26 Commissioning preparation check record - Water Mist. System...27 Commissioning preparation check record - Field check (HVAC)...28 Commissioning preparation check record - Diesel Engine...29 Commissioning preparation check record - Field P&ID Check...30 NORSOK standard Page 21 of 26
23 Annex B Rev. 1, May 1996 COMM. PREPARATION CHECK RECORD ELECTRICAL EQUIPMENT (Rev. 1, May 1996) Check Record No.: <Project> System : Site Code : Area: Subsystem : Comm.Package No. : Tag No : Description : P.O. No. : Supplier : Chkp. Check Status No. Description Supplier Onshore Offshore 01 Mechanical Completion Status. 02 Preservation removed. 03 Equipment cleaned. 04 Earthing correctly installed. Megger-test performed. 05 Living Up Notice (LUN) obtained. 06 In Operation Tag fitted. 07 All Safety Requirements satisfied. Executor Name Date: Verified by: Date: Supplier: Onshore: Offshore: NORSOK standard Page 22 of 26
24 Annex B Rev. 1, May 1996 COMM. PREPARATION CHECK RECORD WATER MIST SYSTEM (Rev. 1, May 1996) Check Record No.: <Project> System : Site Code : Area: Subsystem : Comm.Package No. : Tag No : Description : P.O. No. : Supplier : Chkp. Check Status No. Description Supplier Onshore Offshore 01 Mechanical Completion status. 02 Maintenance access. 03 Operation access. 04 Equipment cleaned. 05 Preservation removed. 06 Valve stroked (Do Not Release). 07 Water tank filled. 08 Air bottle charged. 09 Operating instruction visible. 10 Piping/nozzle system: Use MC Check Record. Executor Name Date: Verified by: Date: Supplier: Onshore: Offshore: NORSOK standard Page 23 of 26
25 Annex B Rev. 1, May 1996 COMM. PREPARATION CHECK RECORD FIELD CHECK (HVAC) (Rev. 1, May 1996) Check Record No.: <Project> System : Site Code : Area: Subsystem : Comm.Package No. : Tag No : Description : P.O. No. : Supplier : Chkp. Check Status No. Description Supplier Onshore Offshore 01 Mechanical Completion status. 02 Maintenance access. 03 Operational access. 04 Equipment cleaned. 05 Preservation removed. 06 Inspection hatches. 07 Flexible connections. 08 Bulkhead penetrations. 09 Supports set. 10 Sufficient insulation. 11 Flow directions correct. 12 All instruments hooked up. 13 All safety precautions carried out. 14 Dust blinds removed. 15 Check according to D&ID Executor Name Date: Verified by: Date: Supplier: Onshore: Offshore: NORSOK standard Page 24 of 26
26 Annex B Rev. 1, May 1996 COMM. PREPARATION CHECK RECORD DIESEL ENGINE (Rev. 1, May 1996) Check Record No.: <Project> System : Site Code : Area: Subsystem : Comm.Package No. : Tag No : Description : P.O. No. : Supplier : Chkp. Check Status No. Description Supplier Onshore Offshore 01 Mechanical Completion status. 02 Maintenance access. 03 Operational access. 04 Dustblindes removed. 05 Safety valves installed. 06 Blinds correct status. 07 Preservation removed. 08 Externally clean. 09 Check all filters. 10 Lubricants filled. 11 Aux. Lubricant Oil pump run. 12 Engine hand cranked 2 turns. 13 Alignment checked. Use MC Check Record. 14 Coupling filled. 15 Radiator checked. 16 Coolant filled. 17 Aspirating system checked. 18 Exhaust system checked. 19 Start system checked. 20 Crank case vent checked. 21 Fuel supply system checked/filled. 22 Remote shut down ready. Executor Name Date: Verified by: Date: Supplier: Onshore: Offshore: NORSOK standard Page 25 of 26
27 Annex B Rev. 1, May 1996 COMM. PREPARATION CHECK RECORD FIELD P&I DIAGRAM CHECK (Rev. 1, May 1996) Check Record No.: <Project> System : Site Code : Area: Subsystem : Comm.Package No. : Tag No : Description : P.O. No. : Supplier : Chkp. Check Status No. Description Supplier Onshore Offshore 01 All pressure tests included in Commissioning pack. 02 Adjust and set pipe supports. 03 Valves and equipment flow direction correct. 04 Blinds installed in correct position. 05 Orifice plates installed. 06 All instruments hooked up. 07 Insulation and heat tracing sufficient. 08 Check free movement of manual valve handles. 09 Remove dustblinds against safety valves etc. 10 Install required temporary filters. 11 Install required temporary blindings. 12 Install required temporary piping/hoses. 13 Required video inspection carried out. 14 Remove preservation where necessary. 15 Mark piping with Comm. tape/warning signs. Executor Name Date: Verified by: Date: Supplier: Onshore: Offshore: NORSOK standard Page 26 of 26
COMMISSIONING OF HVAC SYSTEMS
FORM CL-01 SYSTEMS / EQUIPMENT INCLUDED : SYSTEM STARTUP CHECKLIST I - PRE - STARTUP INSPECTION EQUIPMENT MOUNTING & SETTING CONTROL, INTERLOCK & POWER WIRING ALIGNMENT OF MOTORS & DRIVES PIPING, CONNECTIONS
26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
PUMP MAINTENANCE SCHEDULE AND CHECKLISTS
PUMP MAINTENANCE SCHEDULE AND CHECKLISTS Providing a maintenance schedule defined specifically by run hours or yardage pumped serves only as a general guideline given the large amount of variables a unit
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
Mechanical Installation
Page -1-1. INTRODUCTION AND PURPOSE 1.1. This specification covers the installation, testing and precommissioning of mechanical equipment. Work is to be performed in conjunction with the manufacturer s
Mechanical Engineering Technician- Plant Technician
Mechanical Engineering Technician- Plant Technician A competent Mechanical Engineering Technician- Plant Maintenance is expected to: 1. Ability to plan and execute work in a safe and responsible manner
IMPORTANT SAFETY NOTICE
IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will minimize your risk of injury. ITT Goulds
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will
SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT)
SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT) MAINTENANCE TYPE: STATUTORY 1.0 SCOPE OF SERVICES The Contractor shall provide maintenance Services for
Essentials Welding QA/QC Plan Sample
Essentials Welding QA/QC Plan Sample Good for smaller projects and bid qualifications Has All the Essential Elements of a well-founded Quality Control Plan Contact: Ed Caldeira 410-451-8006 Pat [Pick the
BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION
Air Conditioning Central Heating & Cooling BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION INSTALLATION AND SERVICE MANUAL 2 PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: PHONE NUMBER: INSTALLATION
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 24 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia S TABLE OF CONTENT SCOPE 2 DEFINITIONS
NORSOK STANDARD H-001 Rev. 4, Nov. 2001. Heating, ventilation and air-conditioning
NORSOK STANDARD H-001 Rev. 4, Nov. 2001 Heating, ventilation and air-conditioning This NORSOK standard is developed by NTS with broad industry participation. Please note that whilst every effort has been
& Start-up Directory
& Start-up Directory INTEGRATED SERVICE SOLUTIONS Index C H A P T E R 1 INTRODUCTION 4 C H A P T E R 2 COMMISSIONING & START UP SERVICE 5 2.1 Standard Implementation Path 6 2.2 The Home Office Phase 7
Fire Pump Plan Review March 2010
Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:
NORSOK STANDARD COMMON REQUIREMENTS CRITICALITY CLASSIFICATION METHOD
NORSOK STANDARD COMMON REQUIREMENTS CRITICALITY CLASSIFICATION METHOD Rev.1, May 1996 Please note that whilst every effort has been made to ensure the accuracy of the NORSOK standards neither OLF nor TBL
Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)
17 Engine-Lubrication system (Page GR-17) Lubrication system components, removing and installing Oil pan, removing and installing Oil pressure and oil pressure switch, checking Dynamic oil pressure warning
Engineered Solutions
Engineered Solutions Long established partnerships bring together the world s leading instrumentation companies within BKW. Our manufacturing facility enables us to quickly adapt standard instruments to
SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
SECTION 11 78 13 MORTUARY REFRIGERATORS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in
PBX Series Quick Fit Connector Bimetallic Steam Traps
6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
BERMAD Fire Protection
400E-2M/700E-2M IOM Bermad Electrically Controlled Deluge Valve with EasyLock Manual Reset Model: 400E-2M/700E-2M INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 400E-2M/700E-2M Bermad
Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier
Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier A. Requirement This document is to be used to specify the physical and operational
HVAC Preventative Maintenance Basics. Presented by Mike Crawley
HVAC Preventative Maintenance Basics Presented by Mike Crawley Air Handlers/Package Units: Coils have to be clean! The main purpose of any coil is to absorb or reject heat If coils are dirty; air flow
ELECTRIC/DIESEL FIRE PUMP CHECK LIST
BUILDING NAME: DESIGNER: SCO REPRESENTATIVE: PUMP MANUF.: LOCATION: INSTALLER: DATE: OWNER NAME: INSTALLATION Certificate for flushing and hydrostatic test furnished Piping been hydrostatically tested
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business
Assembly overview - fuel tank
Assembly overview - fuel tank vw-wi://rl/n.en-gb.k02589829.wi::33090894.xml?xsl=3 Page 1 of 2 Assembly overview - fuel tank 1 - Fuel tank 2 - Sleeve When removing, support using engine and gearbox jack
Evaluate, Clean, and Tune Guidance
Evaluate, Clean, and Tune Guidance The Evaluate, Clean and Tune (ECT) process serves three essential purposes in the Weatherization Assistance Program (WAP). The first is to evaluate the existing system
SECTION 23 81 43 HEAT PUMPS
SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 32 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia INSTALLATION, FLUSHING AND TABLE OF
CEILING CASSETTE FAN COIL UNIT
CEILING CASSETTE FAN COIL UNIT Operation and Installation Manual MHCFC4W-04, 08, 12, 16 Four way ceiling cassette fan coil unit Please read this manual before using the fan coil unit. Installation and
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
1300 MAXTRAK SPECIFICATION
CONE CRUSHER Crusher type: Liners: Standard concave: Lubrication: Adjustment: Control: Concave options: 1300 Automax Crusher. Manganese steel alloy mantle and concave. Medium Coarse. Pumped system having
EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.
EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board. This Troubleshooting Guide covers the electric coolant valve and control
Consortiwm Awdurdodau Lleol Cymru Consortium Local Authorities Wales
Consortiwm Awdurdodau Lleol Cymru Consortium Local Authorities Wales SPECIFICATION FOR LAUNDRY EQUIPMENT MAINTENANCE Maintenance Module 32 March 2011 issue This document has been compiled by the Engineering
Standard Hydraulic Piping Flushing Procedure
Page 1 of 6 1.0 Scope This procedure covers the minimum technical requirements for cleaning and flushing of Hydraulic and Piping, and related accessories. 2.0 Introduction In hydraulic fluid power systems,
TRANSNET PIPELINES. TPL 25 Tarlton Commissioning Plan
TPL 25 Tarlton Commissioning Plan Issue Date: 03/07/2015 Revision No.: A Project No.: 11992 Date: 03/07/2015 Document Title: TPL25 Tarlton Commissioning Plan Author: Edward Standen Revision Number: A Checked
The city of Milwaukee s Sample Preventative maintenance manual for Electronically monitored boilers
The city of Milwaukee s Sample Preventative maintenance manual for Electronically monitored boilers Table of Contents Introduction... 1 Intention... 2 Authority and responsibility letter... 3 Organizational
3620 W 11th Streetб Houston, TX 77008 Telephone: 713-635-6291 Email: [email protected] Website: www.kellogg-american.com
Unpackaging & Handling Be sure to carefully inspect the unit before accepting the shipment. If any damage has occurred document it with the trucking company immediately. Contact your Kellogg Distributor
Topics of the Presentation
Drill Rig Safety Topics of the Presentation Personnel safety and monitoring PPE Health (Drugs and Alcohol) Drill Rig operation Safe set up procedures Safe operation of machine Safety related accidents
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF) Please read these instructions thoroughly before installation and ensure they are passed
Operators manual Basic water heater
Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,
REMOVAL AND INSTALLATION
303-01C-1 REMOVAL AND INSTALLATION Engine Body On Special Tool(s) Adapter For 303-D043 303-D043-02 or equivalent Special Tool(s) 303-01C-1 Turbocharger Lifting Bracket 303-1266 Wrench, Fan Clutch Nut 303-214
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
Integrated Custom Systems
Integrated Custom Systems Compact panels Standard Manifolds & Assemblies Electronic pressure control Custom manifolds & Assemblies Automated test benches S t r e a m l i n e y o u r p r o c e s s Complete
Annex-A TECHNICAL SPECIFICATION
Annex-A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 0.4kV (2,000kVA) DIESEL GENERATOR 1 1.0 SCOPE This specification covers the requirements of design, manufacture, delivery
JUBILEE TECHNICAL TRAINING CENTRE TAKORADI POLYTECHNIC 2015 TRAINING PROGRAMMES
JUBILEE TECHNICAL TRAINING CENTRE TAKORADI POLYTECHNIC 2015 TRAINING PROGRAMMES Main Courses Duration: 26 weeks 1. NVQ Level 2 Performing Process Operation in Replicating Environment 2. NVQ Level 2 Performing
Preventive Maintenance. State Energy Assessment Workshop By: DTE Energy Partnership & Services
Preventive Maintenance State Energy Assessment Workshop By: DTE Energy Partnership & Services Do you know? World wide research has shown that one of the reasons causing 80% of the accidents is deficient
Chapter 7 Hydraulic System Troubleshooting
Chapter 7 Hydraulic System Troubleshooting General The following troubleshooting information is provided as a general guide to identify, locate and correct problems that may be experienced with the hydraulic
Competency Framework for Marine Engineer Class 6. Competency Framework for Marine Engineer Class 6
Table of Contents (MEC 6)... 1 Function: Operate Vessel Machinery and Systems... 1 Diesel engines.... 1 Operational procedures.... 3 Operate and monitor a vessel s engines and auxiliary equipment.... 4
Hydraulic control unit series 0086-372-01
Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3
Factory owners must ensure the boiler is:
Factory owners must ensure the boiler is: * Registered with the Boilers and Pressure Vessels Division, Labour Department * Examined by an appointed examiner and has a valid certificate of fitness * Supervised
DIESEL TRUCK MECHANIC 47.0605 GENERAL SKILLS. *A. 001 Define specific safety terms.
DIRECTIONS Evaluate the student by checking the appropriate box to indicate the degree of Competency. The rating for each task should reflect employability readiness rather than the grades given in class.
Maintaining Fire Protection Systems
Maintaining Fire Protection Systems Fire continues to be a major threat to your business and your personal safety. Each year several thousand people are injured or killed by fires and billions of dollars
D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.
SECTION 263354 STATIC UPS TESTING AND COMMISSIONING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes 1. System start-up services. 2. Battery charging. 3. Load bank testing. 4. Battery load testing. 5.
! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
Installation, operation and maintenance manual
Installation, operation and maintenance manual TWO POST LIFT HCT2.1AL30 HCT2.1AL40 HCT2.5AL30 HCT2.5AL40 READ THIS ENTIRE MANUAL BEFORE INSTALLATION TO ENSURE A CORRECT OPERATION AND LONG SERVICE LIFE
Magnum Mobile Generator MMG55 Specifications
Empowering Real People Magnum Mobile Generator MMG55 Specifications ENGINE John Deere PE5030TF270 - turbocharged, diesel engine o Prime - 72 hp @ 1800 rpm o Standby - 80 hp @ 1800 rpm o 4 cylinder o 3.0
SECTION 263235 STANDBY GENERATOR TESTING AND COMMISSIONING
SECTION 263235 STANDBY GENERATOR TESTING AND COMMISSIONING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standby generators. 2. Automatic Transfer Switches (ATS). 3. System start-up services. 4.
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction
Cooking at the Speed of light!
Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide
INSTALLATION COMMISSIONING
SPECIFICATION PREFACE SHEET DEPARTMENT: Engineering / Electrical SHEET 1 OF 13 AREA: Norðurál Grundartangi Reduction Plant SPEC No: REV: C2 STANDARD TECHNICAL SPECIFICATION FOR INSTRUMENTATION INSTALLATION
Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank
Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank This specification describes requirements for a Diesel Fuel Day Tank System consisting of one or more fuel tanks, an Electronic
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 19 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES
P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.
This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product
Cooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering
Model: 400E-2M Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset Installation Operation Maintenance Application Engineering BERMAD 1. Safety First BERMAD believes that the safety
Attachment J-C18.1. HVAC Work Instructions
. RFP: Attachment J-C18.1 HVAC Work Instructions NNC13ZFD017J SOW Item No. Title Page C18-02 Control Air Systems Annual PM 2 C18-03 Split System AC Indoor Section Annual PM 3 C18-04 Condensing Unit Semi-Annual
A. The Commissioning Authority (CxA) has been contracted or will be contracted directly with the Owner for this project.
DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION 23 08 02 PART 1 GENERAL 1.01 AUTHORITY (CxA) A. The Commissioning Authority (CxA) has been contracted or will be contracted directly
This kit may void factory warranty please check with manufacturer.
Mfg Company TM Thank you for purchasing a Sinister Manufacturing Company EGR delete kit. Precision manufactured using aircraft quality 304 stainless steel and billet aluminum; this EGR kit is designed
SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT
SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT INTRODUCTION No matter how reliable fire protection equipment may seem, periodic maintenance is needed to ensure proper operation. Fire protection
BERMAD Fire Protection
Model: 400E-2M BERMAD Electrically Controlled Deluge Valve with Easy Lock Manual Reset Installation Operation Maintenance Safety First BERMAD believes that the safety of personnel working with and around
Section 7 Adjustment, Repair and Replacement
Section 7 Adjustment, Repair, and Replacement Page 7-1 Section 7 Adjustment, Repair and Replacement Section Contents Page Overview...7-5 Belts Belt Guard Removal/Installation...7-7 Belt Removal/Installation...7-11
Preventative Maintenance Plan. Guide. The Simple, Smart Way To Properly Care For Home Systems And Appliances.
Preventative Maintenance Plan Guide The Simple, Smart Way To Properly Care For Home Systems And Appliances. Protect. Prevent. Preserve. Prolong. What AHS Preventative Maintenance Plans Can Do For Your
ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR 1910.147 THE CONTROL OF HAZARDOUS ENERGY (LOCKOUT / TAGOUT) SECTION: 2400
OSHA REGULATION: 29 CFR 90.7 THE CONTROL OF HAZARDOUS ENERGY (LOCKOUT / TAGOUT) DATE: 0/5/2008 DATE: /2/202 A. POLICY. This procedure follows requirements set forth in 29 CFR 90.7. 2. It is the policy
PIPING DRAWINGS BASICS N.P.TODKAR
PIPING DRAWINGS BASICS N.P.TODKAR There are two types of views used in the piping drawings: a) Orthographic- Plans and Elevations b) Pictorial - Isometric Views Piping layout is developed in both plan
D Youville College July 31, 2008 New Academic Building Cannon Design Project No. 002935.00
SECTION 22 6119 - COMPRESSED-AIR EQUIPMENT FOR LABORATORY AND HEALTHCARE PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged, oilless scroll air compressors. 1.2 DEFINITIONS A. Actual Air: Air
Installation Instructions for Alarm Module Kit A043F059
Instruction Sheet 07-2013 Installation Instructions for Alarm Module Kit A043F059 1 Introduction The information contained within is based on information available at the time of going to print. In line
Float and Thermostatic Traps Series H, C and X
Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT
POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT
POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric
OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES
OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES Reference: National Fire Protection Association (NFPA) Pamphlet No. 58 Liquefied Petroleum Gas Code, 2001, Chapter 11 Type of Facility: Petroleum
FPS4 APPENDIX A (INTERIM) SPECIFICATION FOR THE INSPECTION AND TESTING OF AUTOMATIC FIRE SPRINKLER SYSTEMS
FPS4 APPENDIX A (INTERIM) SPECIFICATION FOR THE INSPECTION AND TESTING OF AUTOMATIC FIRE SPRINKLER SYSTEMS To be used in conjunction with the Fire Protection Association Australia FPS4-2000: Agreement
Acumen Enterprises, Inc.
Hourly rates Discount w/o Rebate Electrician $78.00 10% $70.20 $70.73 HVAC Technician $78.00 10% $70.20 $70.73 Insulator $42.00 10% $37.80 $38.08 Sheet Metal Worker $74.00 10% $66.60 $67.10 Plumber/Pipefitter
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description
Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR
Assessment of Elevator and Escalator Maintenance & Repair Program Final Elevator Audit Submission Bethesda Station - Escalator A09X04 (Station)
Bethesda Station - Escalator A09X04 (Station) Ride Quality Test Results The Parametricoder is a time and displacement encoding system that measures mechanical performance characteristics on escalators.
A Job Safety Execution Plan is required. mixtures of the above called, natural gas liquids (NGL's) refined products and their components
TITLE Pipelines and Terminals Manual/Volume 3 - SECTION 02: SUBJECT 20: PURPOSE AND SCOPE During the normal lifetime of a pipeline it becomes necessary to add or remove piping, modify existing piping or
Series 30000 Hose Reels
Operating Instructions and Parts List for Series 30000 Hose Reels - MANUAL DRIVEN - - POWER DRIVEN - SAFETY PRECAUTIONS Personal injury and/or equipment damage may result if proper safety precautions are
PC1131 Electric Air Compressor
Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1131 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in
How To Fix A Car With A Carbide Engine
Section 12 Adjustment, Repair, and Replacement Page 12-1 Section 12 Adjustment, Repair and Replacement Section Contents Page Overview...12-5 Belts Belt Guard Removal/Installation...12-7 Belt Removal/Installation...12-11
System Saver 318 Air Compressor for Mack E-Tech and ASET Engines
Maintenance Manual 31 System Saver 318 Air Compressor for Mack E-Tech and ASET Engines Revised 08-05 NON-THROUGH DRIVE THROUGH DRIVE Service Notes About This Manual This manual provides service and repair
Electric Panel Pump Control System. Operation, Maintenance and Installation Manual
Manual No. 5EP-OM1-1 Electric Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION... 2 SEQUENCE
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 23 Rev: 01 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 DEFINITIONS
The Embassy of the United States of America invites you to submit an offer for supply and install the following A/Cs:
RFQ number PR4877728 The Embassy of the United States of America invites you to submit an offer for supply and install the following A/Cs: A- Supplying and installing 30 high wall A/C split unit 3HP- 24,000
CalMod Design-Build Electrification Services
SECTION 28 16 00 INTRUSION DETECTION SYSTEM PART 1 - GENERAL 1.1 DESCRIPTION A. This section describes the detailed technical requirements for the Intrusion Detection System (IDS), where the Contractor
SECTION 807 PUMP STATION REHABILITATION
SECTION 807 PUMP STATION REHABILITATION 807-1 DESCRIPTION: Rehabilitation of pump stations shall be defined as the cleaning, removal, repair and/or replacement of any and/or all components including but
Cooling system components, removing and installing
Volkswagen Touareg 3.2 - Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! Hot steam may escape when opening expansion tank.
