1 PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Rubber Flooring 1.02 REFERENCED DOCUMENTS A. ASTM International: 1. F 1344 Standard Specification for Rubber Floor Tile 2. E 648 Standard Test Method for Critical Radiant Flux of Flooring Systems Using a Radiant Energy Source 3. E 662 Test Method for Specific Optical Density of Smoke Generated by Solid Materials. 4. F 2240 Standard Test Method for Rubber Property Durometer Hardness 5. F 925 Standard Test Method for Resistance to Chemicals of Resilient Flooring. 6. F 1514 Standard Test Method for Measuring Heat Stability of Resilient Flooring by Color Change 7. F 970 Standard Test Method for Static Load Limit. 8. D 2047 Standard Test Method for Static Coefficient of Friction as Measured by the James Machine. 9. F 710 Standard Practice for Preparing Concrete Floors to Receive Resilient Flooring. 10. F 1482 Standard Guide to Wood Underlayment Products Available for Use Under Resilient Flooring 11. D 3389 Standard Test Method for Coated Fabrics Abrasion Resistance (Rotary Platform, Double-Head Abrader) 12. D 2199 Standard Test Method for Determining Dimensional Stability of Resilient Floor Tile after Exposure to Heat 13. F 386 Standard Test Method for Thickness of Resilient Flooring Materials Having Flat Surfaces 14. F 373 Standard Test Method for Embossed Depth of Resilient Floor Coverings 15. F 2055 Standard Test Method for Size and Squareness of Resilient Floor Tile by Dial Gage Method 16. F 511 Standard Test Method for Quality of Cut (Joint Tightness) of Resilient Floor Tile 17. D-2859 Standard Test Method for Ignition Characteristics of Finished Textile Floor Covering Materials 18. D 1630 Standard Test Method for Rubber Property-Abrasion Resistance (Footwear Abrader) 19. C 1028 Standard Test Method for Determining the Static Coefficient of Friction of Ceramic Tile and Other Like Surfaces by the Horizontal Dynamometer Pull-Meter Method 20. F 373 Standard Test Method for Embossed Depth of Resilient Floor Coverings 21. D 624 Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers 22. D 395 Standard Test Methods for Rubber Property Compression Set 23. D 792 Standard Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement B. Other Referenced Documents 1. National Fire Protection Association (NFPA): NFPA 255, Test Method for Critical Radiant Flux of Floor Covering Systems Using a Radiant Energy Source. 2. National Fire Protection Association (NFPA) 258 Test Method for Specific Density of Smoke Generated by Solid Materials. 3. California State Title 24, Section 3306 (r) 4. California Safe Drinking Water and Toxic Enforcement Act of 1986 (Proposition 65). 5. The Collaborative for High Performance Schools (CHPS) 6. Title 16, CFR Chapter II, Subchapter D, Part 1630, Standard for the Surface Flammability of Carpets and Rugs (FF 70): 1.03 SUBMITTALS A. Product Data: Submit product data, including manufacturer's specification summary sheet for - specified products B. Shop Drawings: Submit shop drawings showing layout, finish colors, patterns and textures. C. Samples: Submit selection and verification samples for finishes, colors, and textures. D. Quality Assurance Submittals: Submit the following: 1. Test Reports: Certified test reports showing compliance with specified performance characteristics and physical properties. 2. Manufacturer's Instructions: Manufacturer's installation and maintenance instructions. E. Submit the following: 1. Maintenance Data: Maintenance data for installed products in accordance with Division 1 sections. Include methods for maintaining installed products, and precautions against cleaning materials and methods detrimental to finishes and performance. 2. Warranty: Warranty documents specified herein QUALITY ASSURANCE A. Installer Qualifications: Installer experienced in performing work of this section who has specialized in installing work similar to that required for this project. page 1 of 7
2 B. Regulatory Requirements 1. Fire Performance characteristics: Provide rubber floor covering with the following fire performance characteristics as determined by testing products in accordance with ASTM method (and NFPA method) indicated below by a certified testing laboratory or another testing and inspecting agency acceptable to authorities having jurisdiction. a. ASTM E 648 (NFPA 253), Critical Radiant Flux of Floor Covering Systems: Class 1, Greater than 0.45 w/cm2 b. ASTM E 662 (NFPA 258), Specific Optical Density of Smoke Generated by Solid Materials: Passes, (<450) C. Single-Source Responsibility: Obtain rubber floor tile and manufacturer s recommended Adhesive from a single supplier. D. Pre-Installation Meetings: Conduct pre-installation meeting to verify project requirements, Manufacturer s conditions, recommended adhesive depending on product, substrate type and type of installation, manufacturer's installation instructions and manufacturer's warranty requirements. Comply with requirements in Division DELIVERY, STORAGE, AND HANDLING A. General: Comply with requirements in Division 1. B. Ordering: Comply with manufacturer's ordering instructions and lead-time requirements to avoid construction delays. C. Delivery: Deliver materials in manufacturer's original, unopened, undamaged containers with Identification labels intact. D. Storage and Protection: Store materials protected from exposure to harmful weather conditions and acclimated to site conditions at temperature and humidity conditions recommended by manufacturer PROJECT CONDITIONS A. Environmental Requirements/Conditions: In accordance with manufacturer's recommendations, areas to receive rubber floor tile shall be clean, fully enclosed, weather tight with the permanent HVAC set at a uniform temperature of degrees F for 48 hours prior to, during and thereafter installation of rubber tile. Rubber floor tile and adhesive shall be conditioned in the same manner. Rubber tile must be un-boxed at least 48 hours prior to installation in the areas in which it will be installed. B. Existing Conditions: [Specify existing conditions affecting product use and installation] 1.07 SEQUENCING AND SCHEDULING A. Finishing Operations: Install rubber floor tile after finishing operations, including painting and ceiling operations etc., have been completed WARRANTY A. Manufacturer's Materials Warranty: Submit, for Owner's acceptance, manufacturer's standard warranty document. Manufacturer's warranty is in addition to, and not a limitation of, other rights Owner may have under Contract Documents. 1. Warranty Period: 1 year limited warranty commencing on Date of Substantial Completion. Notice of any defect must be made in writing to manufacturer within thirty (30) days after buyer learns of the defect. 2. Limited Wear Warranty: Limited wear warranty available depending on product type/design & type of use. 3. Do not use in, around or near commercial kitchens 1.09 MAINTENANCE A. Extra Materials: Deliver to Owner extra materials from same production run as products installed. Package products with protective covering and identify with descriptive labels. Comply with Division 1 Closeout Submittals (Maintenance Materials) Section. 1. Quantity: Furnish quantity of Rubber floor tile equal to 5% of amount to be installed. 2. Delivery, Storage and Protection: Comply with Owner's requirements for delivery, storage and protection of extra materials. B. Maintenance of finished floor covering to be conducted per Manufacturer s Maintenance Guide. PART 2 PRODUCTS Specifier Note: Retain article below for proprietary method specification. Add product attributes performance characteristics, material standards, and descriptions as applicable. Use of such phrases as Or Equal or Or Approved Equal, or similar phrases may cause ambiguity in specifications. Such phrases require verification (procedural, legal, and regulatory) and assignment of responsibility for determining Or Equal products RUBBER FLOOR TILE A. Manufacturer: Roppe Corporation 1. Contact: P.O. Box 1158 Fostoria, Ohio USA Phone: (419) Fax: (419) page 2 of 7
3 B. Test results: 1. ASTM F 1344: Meets all applicable test requirements (listed in section 1.02) 2. Does not contain any of the hazardous chemicals listed in California Proposition Collaborative for High Performance Schools Low-Emitting Material Criteria: Pass C. Product Warranty: Manufacturer s one year limited warranty for manufacturing defects. D. Limited Wear Warranty: Limited wear warranty available depending on product type/design & type of use. E. Proprietary Product(s): Roppe Rubber Floor Tile 1. Styles #982 Crackle Dimensions Rubber Floor Tile: 2. Style #983 Random Dimensions Rubber Tile 3. Style #984 Random Dimensions Rubber Tile e. Limited Wear warranty: Manufacturer s limited wear warranty of five years for normal commercial traffic. 4. Style # 991 Slate Design 1.) Solid color -# [insert color number], complies with ASTM F 1344, class 1A Homogeneous solid color 2.) Fiesta Tile color# [insert color number], complies with ASTM F 1344, class 1B Homogeneous through mottled class 1B Homogeneous through mottled b. Size: 19 11/16 x 19 11/16 (50cm x 50 cm) c. Nominal Thickness: 1/8 (3.175 mm) 5. Style # 992 Low Profile Raised Circular Design 1.) Solid color # [insert color number], complies with ASTM F 1344, class 1A Homogeneous solid color 2.) Fiesta Tile color# [insert color number], complies with ASTM F 1344, class 1B Homogeneous through mottled class 1B Homogeneous through mottled b. Size: 19 11/16 x 19 11/16 (50cm x 50 cm) c. Nominal Thickness: 1/8 (3.175 mm) Tile thickness without profile: 7/64 (2.78mm): Tile thickness with profile 5/45 (2.82mm): Profile thickness: 1/100 (.254mm). d. Backing: Smooth factory sanded Backing 6. Style # 993 Textured Design 1.) Solid color # [insert color number], complies with ASTM F 1344, class 1A Homogeneous solid color. 2.) Fiesta Tile # [insert color number], complies with ASTM F 1344, class 1B Homogeneous through mottled. class 1B Homogeneous through mottled. 4.) Designer s Choice see section 12 5.) Spike/Skate resistant tile see section 13 b. Size: 19 11/16 x 19 11/16 (50cm x 50 cm) c. Nominal Thickness: 1/8 (3.175 mm) 7. Style # 994 Raised Square Design 1.) Solid # [insert color number], complies with ASTM F 1344, class 1A Homogeneous solid color 2.) Fiesta Tile # [insert color number] - complies with ASTM F 1344, class 1B Homogeneous through mottled. class 1B Homogeneous through mottled page 3 of 7
4 Tile thickness without profile: 1/8" (3.17mm): Tile thickness with profile 9/64" (3.57mm): Profile thickness: 1/45" (.559mm). e. Limited Wear warranty: Manufacturer s limited wear warranty of ten years for commercial traffic. 8. #995 Hammered Design 1.) Solid color # [insert color number], complies with ASTM F 1344, class 1A Homogeneous solid color. 2.) Fiesta Tile # [insert color number], complies with ASTM F 1344, class 1B Homogeneous through mottled. class 1B Homogeneous through mottled. 9. Style # 996 Raised Circular Vantage Profile Design 1.) Solid # [insert color number], complies with ASTM F 1344, class 1A Homogeneous solid color 2.) Fiesta Tile # [insert color number], complies with ASTM F 1344, class 1B Homogeneous through mottled class 1B Homogeneous through mottled c. Nominal Thickness: Tile thickness without profile: 1/8" (3.16mm): Tile thickness with profile 5/32" (3.97mm): Profile thickness: 1/32 (.793mm). d. Backing (select one) 1.) Smooth factory sanded backing, Nominal Thickness: 1/8" (3.175 mm) 2.) Lug Back, nominal thickness: Tile thickness without profile: 11/64" (4.36mm): Tile thickness with profile 13/64 (5.16mm): Profile thickness: 1/32" (.793mm). e. Limited Wear Warranty: Raised Circular Vantage Profile Manufacturer s limited wear warranty of ten years for heavy commercial traffic. Raised Circular Vantage Profile Lug-Back Manufacturer s limited wear warranty of five years for normal commercial traffic. 10. Style # 953 Warning Tile Design a. Color: Solid color # [insert color number], complies with ASTM F 1344, class 1A Homogeneous solid color b. Size: 12" x 12" (304.8 mm x mm) Tile thickness without profile: 1/20" (1.27mm): Tile thickness with profile 1/8" (3.16mm): Profile thickness: 2/25" (2.03mm). d. Limited Wear warranty: Manufacturer s limited wear warranty of 5 years for normal commercial traffic. 11. Smooth Finish Rubber Tile : 1.) Solid color # [insert color number], complies with ASTM F 1344, class 1A Homogeneous solid color 2.) Marbleized color # [insert color number], complies with ASTM F 1344, class 1B Homogeneous through mottled b. Size and nominal thickness (select one): 1.) 12" x 12" x 1/8" (304.8 mm x mm x 3.175mm) 2.) 12" x 12" x 3/6" (304.8 mm x mm x 4.76 mm) 3.) 19 11/16" x 19 11/16" x 1/8" (50cm x 50 cm x 3.175mm) 4.) 19 11/16" x 19 11/16" (50cm x 50 cm x 4.76 mm) 5.) 36" x 36" x 1/8" (91.4 cm x 91.4 cm x mm) c. Backing: Smooth factory sanded backing d. Limited Wear warranty: Manufacturer s limited wear warranty of five years for normal commercial traffic. 12. Designer s Choice Texture Design Rubber Tile [Specifier note: The Roppe Designer s Choice system consists of 11 geometric shapes that can be combined to create manufacturer s standard patterns or a custom pattern. Each pattern consists of two or more shapes that are available in manufacturer s standard colors. Specify pattern, shapes used in pattern and color of each shape. Include a drawing of the pattern with specification documents.] a. Pattern # [insert manufacturer s standard pattern #] or specifier s custom pattern, per attached drawings. b. Shape [insert shape and size per manufacturers standard shapes] c. Color [select one color for each shape used] 1.) Solid color # [insert color number], complies with ASTM F 1344, class 1A Homogeneous solid color. 13 Spike/Skate Resistant Textured Design rubber floor tile a. Color # [insert color number], complies with ASTM F 1344, class 1A Homogeneous solid color. c. Nominal Thickness: 11/32 (8.731mm) e. Limited Wear Warranty: Manufacturer s limited wear warranty of five years for heavy commercial traffic. \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ 2.02 BONDED RUBBER CRUMB FLOOR COVERING A. Manufacturer: Roppe Corporation 1. Contact: P.O. Box 1158 Fostoria, Ohio USA Phone: (419) Fax: (419) page 4 of 7
5 B. Proprietary Products: 1. Roppe Recoil Fitness Flooring, homogeneous rubber product manufactured from Vulcanized post-industrial rubber color chips (EPDM) and vulcanized post-consumer tires, bonded with urethane binder. 2. ASTM Test results: a. D-3389 (H-18 Wheels, 500 g/load, 1000 cycles) Taber Abrasion: < 0.50 grams weight loss. b. C 1028 Static Coefficient of Friction (Slip Resistance): 0.88 dry. c. F 373, Thickness Tolerance: +/ " d. D 624 Die C, Tear Strength: 70ppi e. F 137, Flexibility: Passes 6mm Mandrel f. F 1514, Resistance to Heat: Delta E: 2.24 and AATCC Gray Scale: 3.85 average. g. F 925 Resistance to Chemicals: Pass. (Staining Agent List available from manufacturer) h. F 970 Static Load Limit: 250 psi, (modified 400 psi). i. D-2240 Hardness Shore A: 60 +/- 5 j. D 395 Compression Set: 12% or less. k. D-792 Density PCF: 65lbs/cu/ft l. Roll Material Width Tolerance: +/- _ 3. Square, Interlocking Tile & Roll Nominal thickness (select one) 5/32" (4.00mm), 1/4" (6.00mm), 3/8" (9.00mm), 1/2" (12.00mm) 4. Nominal Size (select one) a. Rolls: 48" (1.22m) x 49.5 feet (15.09m) b. Square edge tile: 36" x 36" (914.4mm x 914.4mm) c. Inter-locking tile (measured from outside tabs) 36" x 36" (914.4mm x 914.4mm) 5. Color: Manufacturer s standard colors, custom colors & percentage of EPDM color content as selected by architect. 6. Product Warranty: Manufacturer s three year limited warranty for manufacturing defects RECYCLED RUBBER TIRE FLOOR TILE A. Manufacturer: Roppe Corporation 1. Contact: P.O. Box 1158 Fostoria, Ohio USA Phone: (419) Fax: (419) B. Test results: 1. ASTM D 2047, Static Coefficient of Friction: > 0.80 dry. 2. ASTM D-2859, Pill Test: Pass 3. ASTM D-1630, Taber Abrasion: Less than.003" at 5000 cycles using H-10 wheels 4. Title 16, CFR Chapter II, Subchapter D, Part 1630, Standard for the Surface Flammability of Carpets and Rugs (FF 70): Passes C. Product Warranty: Manufacturer s one year limited warranty for manufacturing defects, Lifetime delamination warranty, 10-year limited wear warranty. D. Nominal Sizes: 12" x 12" (304.8mm x 304.8mm) Square Tile & 12" x 30' (304.8mm x 9,140.4 mm) Rolls. E. Color (select one): Earthtone (# POET), Indigo (# POIN), Crimson (# POCR), Pine (# POPN) F. Proprietary Product(s) Roppe Rop-Cord Recycled Tire Tile (select one): 1. Rop-Cord Vulcanized a. Manufactured with approximately 95% of the components of recycled truck and bus tires. b. Construction: Synthetic tire cord reinforced with a layer of fabric, vulcanized to a thin rubber backing and buffed to a non-glare tufted surface c. Nominal Thickness: nominal 5/16" (7.92mm) 2. Rop-Cord Non-Vulcanized a. Manufactured with approximately 95% of the components of recycled truck and bus tires. b. Construction: Synthetic tire cord reinforced with a layer of fabric, vulcanized to a thin rubber backing and buffed to a non-glare tufted surface c. Nominal Thickness: nominal 3/8" (9.52 mm) PART 3 EXECUTION 3.01 MANUFACTURER'S INSTRUCTIONS A. Compliance: Comply with manufacturer s requirements as published in Roppe installation instructions. B. Adhesive (Select one): 1.) [For products listed in Section 2.01 (Roppe Rubber Tile)], Roppe, 375 #435 or # 535U, as required, based on job site conditions, substrate type and planned use of finished floor. 2.) [For products listed in Section 2.02 (Roppe Recoil Rubber Flooring]), Roppe # for indoor & outdoor use. 3.) [For products listed in section 2.03 (Roppe Rop-Cord Tile)], (select one) a. Roppe # 445 for outdoor & indoor use b. Roppe # 435 for indoor use (must be used for rolling loads & lateral sheer stress). page 5 of 7
6 3.02 EXAMINATION A. Site Verification of Conditions: Confirm substrate conditions (which have been previously addressed under other sections) are acceptable for product installing in accordance with manufacturer's instructions. B. Material Inspection: In accordance with manufacturer's installing requirements, visually inspect materials prior to installing. Material with visual defects shall not be installed PREPARATION A. Adjacent Surfaces Protection: Protect adjacent work areas and finish surfaces from damage while installing. B. Surface Preparation, General: Prepare substrate in accordance with manufacturer's instructions. C. Substrate: Prepare substrate to be free of paint, old adhesive, sealers, coatings, finishes, dirt, film-forming curing compounds, and all other substances which may affect the adhesion of floor covering to the substrate. 1. Concrete Substrate: Reference Standard ASTM F 710 Standard Practice for Preparing Concrete Floors to Receive Resilient Flooring. a. Concrete Moisture Test: Per ASTM F 710 section 5, persons or testing agencies with experience in concrete moisture testing shall perform moisture tests on concrete regardless of its age or grade level or history of use, with a minimum of three tests for the first 1000 square feet and one additional test for each 1000 square feet or fraction thereof, per grade level. A diagram of the area showing the location and results of each test shall be dated and submitted to the architect, general contractor and/or end user. If the test results exceed the floor covering manufacturer s limits, installing shall not commence until results conform to limits. b. Concrete ph Test: Perform ph tests on concrete regardless of its age or grade level or history of use. Readings below 7.0 and above 10.0 can adversely affect resilient flooring or adhesives, or both. If the test results exceed the floor covering manufacturer s limits, installing shall not commence until results conform to limits. 2. Wood Substrate: Per ASTM F1482, Wood subfloor/underlayment assemblies shall be double layer construction, with a total thickness of not less than 1. a. There shall be minimum 18 inches of well-ventilated air space beneath all wood subfloors. Crawl spaces shall be insulated and protected by a moisture vapor barrier. b. Do not install over sleeper underlayment systems or wood underlayment installed over concrete. c. Do not install over Lauan panels, CCA Plywood, Fire rated plywood, plywood with knots, underlayment made of pine or other soft woods, particle board, Oriented Strand Board (OSB) MasoniteTM or other hardboard underlayment, hardwood flooring, textured or cushioned flooring, treated or otherwise coated wood material or other uneven or unstable substrates. Unacceptable surfaces shall be covered using a 1/4-inch or thicker panel underlayment per section d. d. Wood Underlayments: Use only plywood underlayment that is warranted by the underlayment manufacturer for use as an underlayment for sheet vinyl floor covering in commercial applications. Do not use Lauan. e. Refer to Division 6 Carpentry sections for wood subfloor construction. 3. Refer to manufacturer s installation instructions regarding installations over existing ceramic tile, cementitious terrazzo and metal. 4. Do not install over existing floor covering nor over substrates not approved by manufacturer INSTALLING A. Refer to Roppe 10-Part Specification Sheet for rubber tile installation instructions for detailed specifications on installing Roppe Rubber Floor Tile. B. Finish Floor Covering Designs: As selected by Architect. C. Accessories: Architect shall specify manufacturers color coordinated rubber accessories as required, including (but not limited too) Resilient wall base, stair nosing, reducers or other edgings, welding rods for heat welded seams FIELD QUALITY REQUIREMENTS A. Manufacturer's Field Services: Upon Owner's request and with minimum 72 hours notice, provide manufacturer's field service consisting of product use recommendations and periodic site visits to confirm installing of product is in accordance with manufacturer's instructions. 1. Site Visits: [Specify number and duration of periodic site visits.] page 6 of CLEANING A. Cleaning: See Roppe maintenance instructions. Remove temporary coverings and protection of adjacent work areas. Repair or replace damaged installed products. Clean installed products in accordance with manufacturer's instructions prior to owner's acceptance. Remove construction debris from project site and legally dispose of.
7 3.07 PROTECTION A. Protection: Protect installed product and finish surfaces from damage during construction. Remove and Legally dispose of protective covering at time of substantial completion. B. Keep foot traffic off new floor covering for first 48 hours. C. Keep furniture, fixtures and rolling traffic off for first 72 hours. D. No maintenance for first 72 hours INITIAL MAINTENANCE PROCEDURES A. General: Include in contract sum cost for initial maintenance procedures and execution by professional maintenance personnel after floor covering has been installed for three days as specified in the Roppe maintenance instructions. page 7 of 7
SECTION 32 1816 PLAYGROUND SURFACING TILES
SECTION 32 1816 PLAYGROUND SURFACING TILES PART 1 GENERAL 1.01 SECTION INCLUDES A. Resilient playground safety surfacing tiles. B. Coordinate with work shown in other sections so the work is installed
Division 9. SignaFlor Pad and Pour Flooring System
Division 9 SignaFlor Pad and Pour Flooring System SPECIFICATIONS Page 1. General... 2 1.1 Description 2 1.2 Quality Assurance 2 1.3 Submittals 2 1.4 Delivery and Storage 3 1.5 Warranty 3 1.6 Working Conditions
07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
07 21 19 STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 7819 Broadview Road Cleveland, OH 44131 800-522-4522 February, 2011 SPEC NOTE: This guide specification is intended for use when specifying
TotTurf Interlocking Tile TotTurf Interlocking Tile Product Specifications TOTTURF a PLAYCORE company August 2012
PART 1 General TotTurf Interlocking Tile 1.01 INTERLOCKING TILE PLAYGROUND SURFACING TotTurf Interlocking Tile playground surfacing shall consist of recycled, compression molded rubber, a color pigment
Specifications, Product Testing and Terminology
Specifications, Product Testing and Terminology The following synopsis provides a review of various material and final product testing, which is performed on our products, as well as, many of our competitors.
1.02 DESCRIPTION A. This Section specifies furnishing and installing Cast in Place Detectable/Tactile Warning Surface tiles where indicated.
CAST IN PLACE DETECTABLE/TACTILE WARNING SURFACE TILE PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Special Conditions and Division 1 Specifications
SECTION 07 42 13 METAL WALL PANELS
Mitsubishi Plastics Composites America, Inc. 401 Volvo Parkway Chesapeake, VA 23320 Phone: (800) 422-7270 Fax: (757) 436-1896 E-mail: [email protected] www.alpolic-northamerica.com This MANU-SPEC utilizes
SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
Guide Specifications for Maple Flooring Systems
Guide Specifications for Maple Flooring Systems MFMA Guide Specification for Resilient Pre-Engineered Fixed Panel System Purpose This Guide Specification is designed to assist in the production of actual
INSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS
INSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS 1. Paragraph 1.02 Provide solid surface countertops at sinks locations. Provide solid surface window sills at drywall framing walls.
2. Division 05 Structural Steel Framing for steel framework requirements
SECTION 131200 - CLIMBING WALLS PART 1 GENERAL 1.1 SUMMARY A. This section includes the following: 1. GFRC Rock Realistic Climbing Wall System B. Related Sections 1. Division 04 Unit Masonry 2. Division
Vinyl Composition Tile Installation System
Vinyl Composition Tile Installation System Product Gauge Size Vinyl No-Wax (Dry Back) Urethane No-Wax (Dry Back) 0.045" (1.1 mm) 0.080" (2.0 mm) IMPERIAL TEXTURE 0.094" (2.4 mm) STONETEX ChromaSpin COMPANION
Bella Cera Engineered Hardwood Flooring Installation Instructions. Check for Proper Color Selection Prior to Installation
Bella Cera Engineered Hardwood Flooring Installation Instructions Check for Proper Color Selection Prior to Installation 1 Important Information before You Begin 1.1 Installer/Owner Responsibility Carefully
GigaCrete Specification PlasterMax
GigaCrete Inc. 6775 Speedway Blvd. Suite M105 Las Vegas, NV 89115 Ph (702) 643-6363 Fax (702) 643 1453 www.gigacrete.com GigaCrete Specification PlasterMax PlasterMax : Fire Rated Plaster for Direct Application
ENTRANCE MATS & GRIDS
152 Rollins Avenue #102 Rockville, MD 20852 800-762-9010 240-780-3309 (f) http://www.americanfloormats.com ENTRANCE MATS & GRIDS PART I - GENERAL 1.01 Summary A. This section includes the following types
RESILIENT TILE FLOORING INCLUDING SOLID VINYL AND LINOLEUM FLOOR TILE
THIS DOCUMENT IS INTENDED AS A SUGGESTED GUIDE FOR CREATING, MODIFYING, OR EDITING YOUR CSI FORMATTED 3-PART ARCHITECTURAL GUIDE SPECIFICATIONS. JOHNSONITE WILL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT
Installation System. Existing Resilient Sheet Floors
Vinyl Composition Tile Installation System Product Adhesive/Full Spread Adhesive/Tile-On Comment Imperial Texture MultiColor RAVE Stonetex Companion Square Feature Tile/Strips ARTEFFECTS SAFETY ZONE Vinyl
Selecting Vinyl Flooring
extension.usu.edu Smart Shopping for Home Furnishings Selecting Vinyl Flooring Dr. Leona Hawks Home Furnishings & Housing Specialist 1987 HI 03 Shopping for vinyl? There are many different varieties of
BENTLEY ELEMENTS COLLECTION LVT
This document refers to the following products: Product Size Installation direction Seams treatment Elements Tiles See specifications 90 None Elements Planks See specifications Stair Step None Note: This
FLOOR TREATMENT 09610
14805 E. Moncrieff Place Aurora, CO 80011 Phone: (800) 872-5515 Phone: (303) 371-1411 Fax: (303) 371-6958 E-mail: [email protected] www.bonakemi.com This MANU-SPEC utilizes the Construction Specifications
SECTION 07 61 13 STANDING SEAM METAL ROOFING
SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced
ROXUL Board Insulation Section 07 21 13 Master Guide Specification (CAVITYROCK ) Page 1 April 2016
Master Guide Specification (CAVITYROCK ) Page 1 Click on the pilcrow in the MS Word Toolbar to toggle ROXUL GUIDE NOTES on and off. Delete this text before incorporating the section into a Project Manual.
SECTION 07 21 16 - PRE-ENGINEERED BUILDING BLANKET INSULATION
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
Product Guide Specification
Reef Industries, Inc. 9209 Almeda Genoa Rd. Houston, Texas 77075 Toll Free (800) 231-6074 Phone (713) 507-4251 Fax (713) 507-4295 Web Site www.reefindustries.com E-Mail [email protected] Product Guide
How to Install Hardwood Flooring Over a Sub Floor
How to Install Hardwood Flooring Over a Sub Floor Installation Preparation Instructions Read the entire instructions before starting your project. 1) INSPECT EACH PLANK (see fig. a) Wood is a natural product
SCENIC VIEW SV 10 SECTION 08 87 13 SOLAR CONTROL FILMS
PART 1 GENERAL SCENIC VIEW SV 10 SECTION 08 87 13 SOLAR CONTROL FILMS 1.1 SUMMARY A. Optically clear dual reflective, neutral sputtered and aluminum metallized polyester film for solar control. 1.2 RELATED
Product Guide Specification
Stabilit America, Inc., dba Glasteel June 2005 285 Industrial Drive Moscow, Tennessee 38057 Toll Free (800) 238-5546 Phone (901) 877-3010 Fax (901) 877-1388 Web Site www.glasteel.com Product Guide Specification
SECTION 07410 METAL ROOF & WALL PANELS
This document specifies Metal Roofing Systems prefinished factory formed metal roofing marketed as MRS System 2500 steel and aluminum roofing systems and includes MRS flashing and Trim. MRS finish is a
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS 1. SCOPE 1.1 This specification covers the type, physical properties and dimensions of Expanded Polystyrene Insulation Board intended for use
Technical Services. Product MM INCH Installation direction Seams treatment GTI CONNECT (interlocking)
INSTALLATION INSTRUCTIONS FOR GTI CONNECT TILES This document refers to the following products: Product MM INCH Installation direction Seams treatment GTI CONNECT (interlocking) 635 X 635 mm 25.5 x 25.5
CLEAR-DIVISIONS CENTERFOLD
CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in
B. Related categories: The following categories contain requirements that relate to this section:
ORIENTED STRAND BOARD PART I. - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply
ARMSTRONG RESIDENTIAL VINYL TILE FLOORING WARRANTY: Professionally Installed & Do It Yourself (DIY)
ARMSTRONG RESIDENTIAL VINYL TILE FLOORING WARRANTY: Professionally Installed & Do It Yourself (DIY) THE ARMSTRONG LIFETIME LIMITED RESIDENTIAL WARRANTY FOR: Abingdon Adiamo Clear Creek Caliber Granville
APPENDIX C MOISTURE GUIDELINES & MOISTURE TESTING
APPENDIX C MOISTURE GUIDELINES & MOISTURE TESTING Appendix C Moisture Guidelines Determining moisture content is an essential part of quality control within the flooring installation process. Flooring
Code of Standard Practice for Timber Frame Structures
TFEC 2-2013 Code of Standard Practice for Timber Frame Structures August 2013 Preface This Code is intended to represent a reasonable consensus of what constitutes ordinary and acceptable practice within
FACILITY FIRE-SUPPRESSION WATER-SERVICE PIPING 21 11 00
211100_flexheadin_01_MS_0409 5/22/09 PTC 56 Lowland Street Holliston, MA 01746 Phone: (800) 829-6975 Phone: (508) 893-9596 Fax: (508) 893-6020 E-mail: [email protected] www.flexhead.com This MANU-SPEC
C. Section 014510 TESTING LABORATORY SERVICE.
SECTION 014500 QUALITY CONTROL PART 1 GENERAL 1.01 RELATED REQUIREMENTS A. Drawings and General Provisions of Contract, including General and Special Conditions and other Division 1 Specification Sections,
Amorim Rubber Flooring Specifications
Amorim Rubber Flooring Specifications Test Method Amorim Typical Value Durometer, Shore A, points of hardness ASTM D2240-97 60 Density, lbs/ft 3 ASTM D297-93 Part A, Section 16.3 64 Compressibility @ 100
CHAPTER 3 MOISTURE TESTING
CHAPTER 3 MOISTURE TESTING Part I - Moisture Testing for Wood Subfloors A. Testing Requirements 1. Test for moisture at several locations in the room a minimum of 20 per 1,000 square feet and average the
SECTION 1 GENERAL REQUIREMENTS
Page 1 of 6 SECTION 1 GENERAL REQUIREMENTS 1. SCOPE OF WORK: The work to be performed under the provisions of these documents and the contract based thereon includes furnishing all labor, equipment, materials,
Armstrong Do-It-Yourself Tile Installation System
Armstrong Do-It-Yourself Tile Installation System What tools will I need to install my tile floor? You'll need just the basics: - floor tile (make sure you have enough tile to finish the job) - adhesive
SECTION 03 35 43. Formatted Specification for the ULTRAFLOR DIAMATIC Topical Polished Concrete System DRAFT
SECTION 03 35 43 Formatted Specification for the ULTRAFLOR DIAMATIC Topical Polished Concrete System PART I GENERAL 1.01 SUMMARY A. This is the recommended specification for ULTRAFLOR DIAMATIC Topical
RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES
1807 Elmwood Avenue, Suite 275 Buffalo, New York 14207 (800) 543-5155 RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES Fiberesin Wall System Provide materials and labor to complete courts
Guide Specification SECTION 09 68 16 SHEET CARPETING PART 1 - GENERAL 1.1 SUMMARY. A. This Section includes broadloom carpet. 1.
SECTION 09 68 16 SHEET CARPETING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes broadloom carpet. 1.2 STANDARDS A. Except as modified by governing codes and by the Contract Documents, comply with
High Strain Dynamic Load Testing of Drilled Shafts
Supplemental Technical Specification for High Strain Dynamic Load Testing of Drilled Shafts SCDOT Designation: SC-M-712 (9/15) September 3, 2015 1.0 GENERAL This work shall consist of performing high-strain
NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK
ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within
Carpet Tile Installation Guidelines
NOTICE FAILURE TO FOLLOW THESE GUIDELINES CAN RESULT IN VOIDING THE CARPET WARRANTY. Installation Guidelines The following instructions should be reviewed prior to installation. Shaw Industries will not
Division 2 Section 32 14 13.19 Section 02795
Note: The text must be edited to suit specific project requirements. It should be reviewed by a qualified civil or geotechnical engineer, or landscape architect familiar with the site conditions. Edit
PREFINISHED SOLID-STRIP BAMBOO FLOORING SIGNATURE NATURALS + SIGNATURE COLORS Multiple Precise Lengths
PREFINISHED SOLID-STRIP BAMBOO FLOORING SIGNATURE NATURALS + SIGNATURE COLORS Multiple Precise Lengths 12715 Miller Road NE, Suite 301 Bainbridge Island WA 98110 Tel: 206.842.9477 Toll-free: 800.929.6333
INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles
INSTALLATION RECOMMENDATIONS Outdoor Rubber Tiles Prior to Installation: The Outdoor Rubber Tiles and accessory transition pieces intended for this installation have been shipped to you via a freight carrier
ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24, 2014 06610-1
ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING January 24, 2014 06610-1 SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS MOLDED GRATING PART 1 - GENERAL 1.1 SCOPE OF WORK A. The CONTRACTOR
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
Engineered Hardwood Flooring Installation Instructions
Engineered Hardwood Flooring Installation Instructions Tip: Check for proper color selection and style prior to Installation. No claims will be accepted after installation Important Information before
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING PART ONE GENERAL DESCRIPTION This section includes pre-formed standing seam metal roofing and related flashings, closures, trim and accessories including,
How To Level A Subfloor
Skill Level: INTERMEDIATE Give these projects a try if you're a confident DIYer with a good working knowledge of a variety of tools. They can take a day or more to complete. If you can build a birdhouse
Section 03 35 43 Polished Concrete Finishing. Vexcon
SS 120 1-13 Section 03 35 43 Polished Concrete Finishing Specifier Note: This product guide specification is written according to the Construction Specifications Institute (CSI) 3-part format. This section
Grand Mesa Plus LAMINATE - WIRE BRUSHED. GAGVGM81012A Prairie. GAGVGM80012NA Colorado. GAGVGM84012A Pecan Rustic. GAGVGM85012A Saddle Walnut
MARCH 2015 Grand Mesa Plus LAMINATE - WIRE BRUSHED Specifications 12.3mm 6.5 wide x 47-13/16 long 19.42 sf/ctn 48 ctn/plt Triple Plate Embossing Wire Brushed Texture Micro-Bevel & Waxed Edges Warranty
1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.
SECTION 075416 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. 1.2 PERFORMANCE REQUIREMENTS A. Solar Reflectance
Crystal Clear Sealant
Crystal Clear Sealant Technical Data February, 2012 Product Description 3M Crystal Clear Sealant is a one component thermoplastic elastomer which forms permanent elastic bonds when used in surface sealing
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
INSTALLATION IMPORTANT INSTALLER/OWNER RESPONSIBILITY TOOLS & EQUIPMENT NEEDED FOR INSTALLATION PRE-INSTALLATION PROCEDURES & JOBSITE CONDITIONS
IMPORTANT It is important that you read & understand the following information and instructions in their entirety before proceeding with installation. Please thoroughly inspect all Flooring products in
CLEAR-DIVISIONS VARIOFOLD
CLEAR-DIVISIONS VARIOFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS VARIOFOLD moveable The yellow highlighted areas in the
Fiberglas, Exterior Wall Thermal Insulation
PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION 623.10 CONCRETE BONDING COMPOUND.
SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION 623.10 CONCRETE BONDING COMPOUND. 623.10.1 Description. This work shall consist of preparing the surface,
SECTION 03400 PRECAST CONCRETE STRUCTURES
SECTION 03400 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for precast concrete structures, including fabrication and erection. 1.02 REFERENCE STANDARDS A. American Society for
BLACK JACK ALL WEATHER ROOF COATING
PAGE: 1 of 6 PRINT DATE: 16/09/2004 BLACK JACK ALL WEATHER ROOF COATING DESCRIPTION BLACK JACK ALL WEATHER ROOF COATING is a solvent based, full bodied black brushable compound with added fibres for reinforcement.
A. Work on this project shall consist of, but is not limited to, the following:
PART 1 - GENERAL CLEANING AND RESTORATION OF SECTION 05900-1 1.1 SUMMARY A. Work on this project shall consist of, but is not limited to, the following: 1. Clean and treat all exposed anodized architectural
Colorado State University. Durrell Center Roof Repair
Colorado State University Durrell Center Roof Repair SPECIFICATION: POLYURETHANE FOAM ROOFING l.0 GENERAL REQUIREMENTS The successful application of a polyurethane foam roofing system is dependent upon
738-B-297 POLYMERIC CONCRETE BRIDGE DECK OVERLAY. (Adopted 02-20-14)
POLYMERIC CONCRETE BRIDGE DECK OVERLAY (Adopted 02-20-14) Description The polymeric concrete bridge deck overlay shall consist of an epoxy polymer that acts together with special aggregate to form an overlay
SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS
Page 1 of 5 SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS Guarda Security Window Screens in this specification are appropriate for use in windows, storefronts, curtain walls, vents, and any other applications
Double Coated Urethane Foam Tapes
3 Double Coated Urethane Foam Tapes 4004 4008 4016 4026 4032 4052 4056 4085 Technical Data April, 2009 Product Description 3M Double Coated Urethane Foam Tapes are conformable foams that offer high shear
A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, 2012. All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA
Page 1 of 10, Addendum No. 3 Temporary Garage Structure City of Chelsea, MA November 5, 2012 CBI Job No.: 12055-A A D D E N D U M # 3 DATE: November 5, 2012 TO: FROM: PROJECT: All Bidders Jenne dos Santos,
SECTION 03 35 43 - POLISHED CONCRETE FINISHING. InovaCrete Polished Concrete Floor Finish (GUIDE SPEC)
SECTION 03 35 43 - POLISHED CONCRETE FINISHING InovaCrete Polished Concrete Floor Finish (GUIDE SPEC) PART 1 GENERAL 1.01 SUMMARY This Section includes information about: A. Polished concrete finish in
RESIDENTIAL HARDWOOD WARRANTIES
RESIDENTIAL HARDWOOD WARRANTIES Limited Warranties for Prefinished Solid and Engineered Hardwood Floors Manufacturing Defects Century Flooring* ("Century") hereby warrants to the original buyer ("Buyer"),
COMMERCIAL BUILDING APPLICATIONS
EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that
ARMSTRONG RESIDENTIAL VINYL TILE FLOORING WARRANTY: Professionally Installed & Do It Yourself (DIY) Menards Products
ARMSTRONG RESIDENTIAL VINYL TILE FLOORING WARRANTY: Professionally Installed & Do It Yourself (DIY) Menards Products THE ARMSTRONG LIFETIME LIMITED RESIDENTIAL WARRANTY FOR: Abingdon Adiamo Clear Creek
Pipe and Equipment Insulations. Zeston. PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems
Pipe and Equipment Insulations Zeston PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems Zeston PVC Insulated Fitting Covers Installation Instructions for Hot,
SC2000 CEMENT BONDING PROCEDURES
Pg.1 SC2000 CEMENT BONDING PROCEDURES Widely recognized as the world s finest cold vulcanizing cement REMA SC2000 is the solution to your industrial bonding problems. By using REMA UTR20 hardener with
A. This Section includes rubberized asphalt sheet membrane waterproofing systems.
SECTION 07110 SHEET MEMBRANE WATERPROOFING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
09 00 03 GENERAL PROVISIONS
09 00 03 GENERAL PROVISIONS A. For renovation projects, consider the building s character and existing finishes. All material patches should blend as closely as possible. Some buildings on campus have
ECOfit Interlocking Tile
ECOfit Interlocking Tile INSTALLATION AND MAINTENANCE MANUAL Manufactured in the U.S.A. by: Revised 09/04/2014 Supersedes all previous versions. Check website for updates. 877-258-0843 www.ecorecommercialflooring.com
PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta
PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification Number: 3503-11.2.610 Rev. 2 Rubber Lined Steel Pipe and Fittings Mechanically Coupled Plain End Type System Issued Revised Approved
SECTION 31 20 00 EARTH MOVING
SECTION 31 20 00 PART 1 - GENERAL 1.01 DESCRIPTION A. This Section describes the requirements for excavating, filling, and grading for earthwork at Parking Structure, new exit stair and as required to
Acceptance Codes APPENDIX - A. Acceptance Criteria
1111 Receipt of a satisfactory Test Report from WSDOT Materials Laboratory is required indicating the lot (or lots) or batch of material meets the requirement of the specifications under which it is listed.
Underwriters Laboratories Testing Information
Underwriters Laboratories Testing Information R-8078 Underwriters Laboratories Inc. R-13173 Classified Spray Fiber Surface burning characteristics applied to inorganic reinforced cement board with a maximum
09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec 03500 Master Spec. 03 49 00 Page 1
C. S. I. Spec 03500 Page 1 PART 1 - GENERAL 1.01 SUMMARY:.01 Provide special glassfiber reinforced cement (GRC) shapes in accordance with the requirements of the contract documents..02 The installing contractor
SECTION 05 42 16 COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex
(Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying cold-formed metal deck framing products and execution. The specifier needs to edit the guide
Herringbone Pattern Flooring
Herringbone Pattern Flooring If it s not marked NOFMA, it s not certified. Handling, Storage, Installation and Tips Herringbone is generally manufactured from 3/4 x 2 ¼ or ¾ x 1-1/2 standard tongue & groove
Wastewater Capital Projects Management Standard Construction Specification
CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 Precast Concrete Pipe 10.1.1 General This section covers material requirements,
3M Bumpon Protective Products Molded Shapes - Colored and Clear Series SJ5000 SJ5300 SJ5400 SJ5500 SJ5700 SJ6100
Technical Data July 2015 3M Bumpon Protective Products Molded Shapes - Colored and Clear Series SJ5000 SJ5300 SJ5400 SJ5500 SJ5700 SJ6100 Product Description 3M Bumpon Protective Products Molded Shapes
CHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
HARDWOOD WARRANTIES Limited Warranty for Prefinished Solid, Engineered, and Longstrip Floors Manufacturing Defects Finish Warranty
HARDWOOD WARRANTIES Limited Warranty for Prefinished Solid, Engineered, and Longstrip Floors Manufacturing Defects Mohawk* ("Mohawk") hereby warrants to the original buyer ("Buyer"), the goods to be free
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES 1 PART 1 - GENERAL 1.0 GENERAL 1.1 REFERENCES: SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED FIBERGLASS
12 POLYURETHANE ADHESIVE (PU 105)
12 POLYURETHANE ADHESIVE (PU 105) DISCLAIMER: Refer to page 5 of this document. 12.1 DESCRIPTION PU 105 is a high performance two-part polyurethane adhesive for both indoor installations of Mondo rubber
Asphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials
ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials SECTION 03 92 50 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings,
How To Replace A Roofing System In Florida
Florida Consumer Considerations in Replacing their Roofing System The Florida Roofing, Sheet Metal and Air Conditioning Contractors Association provides the following general information to help Florida
SECTION 03 54 00 RESURFACING CAST IN PLACE CONCRETE
Page 1 SECTION 03 54 00 RESURFACING CAST IN PLACE CONCRETE Specifier Notes: This guide specification is written according to the Construction Specifications Institute (CSI) format. The section must be
CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS
AN ERGONARMOR COMPANY TECHNICAL INFORMATION SPECIFICATION FOR INSTALLATION 07/11 SUPERSEDES 04/00 PAGE 1 OF 6 CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS 1. SCOPE 1.1 This specification