A NATIONAL MEASUREMENT GOOD PRACTICE GUIDE. No.108. Guide for the Measurement of Smooth Surface Topography using Coherence Scanning Interferometry
|
|
|
- Cora Wells
- 9 years ago
- Views:
Transcription
1 A NATIONAL MEASUREMENT GOOD PRACTICE GUIDE No.108 Guide for the Measurement of Smooth Surface Topography using Coherence Scanning Interferometry
2
3 Measurement Good Practice Guide No. 108 Guide to the Measurement of Smooth Surface Topography using Coherence Scanning Interferometry Richard Leach National Physical Laboratory Leigh Brown, Xiangqian Jiang University of Huddersfield Roy Blunt IQE Ltd Mike Conroy, Darian Mauger Taylor Hobson Ltd ABSTRACT This guide describes good practice for the measurement and characterisation of smooth surface topography using coherence scanning interferometry (commonly referred to as vertical scanning white light interferometry). The guide is based on the measurement of the topography of semiconductors, epitaxial wafers and optical thin film coatings. However, the general guidelines described here can be applied to many flat, smooth surface topography measurements. For the purpose of this guide, the definition of a smooth surface is one that has an approximately random distribution of heights with a roughness (Sz) of less than 50 nm.
4 Crown copyright 2008 Reproduced with the permission of the Controller of HMSO and the Queen's Printer for Scotland ISSN National Physical Laboratory Hampton Road, Teddington, Middlesex, TW11 0LW Acknowledgements This document has been produced and funded by the UK Department of Trade and Industry s Applied Research Programme Micro and Nanotechnology Manufacturing Initiative, Project SOLADIM. Thanks also to Dr Tony Smith and Danny Mansfield (Taylor Hobson), Prof Liam Blunt (University of Huddersfield), Dr Mike Walls (Applied Multilayers), David Flack and Chris Jones (NPL), Dr Erik Novak (Veeco), Dr Carol Daniel (Lambda Photometrics) and Dr Ted Vorburger (NIST) for contributing and suggesting improvements to this guide.
5 i Contents Introduction...1 Scope of this guide...2 Introduction to coherence scanning interferometers...3 Basics of interferometry...3 Coherence scanning interferometry...5 Interferometer objective lenses...8 Terms and definitions...11 General terms used in this guide...12 Surface profile measurement...12 Areal surface texture measurement...12 Sampling area...12 Coherence scanning interferometry...13 Numerical aperture...13 User defined variables...14 Smooth surface...14 Areal surface texture parameters...14 Areal and profile parameters...15 Amplitude parameters...16 Spacing parameters...19 Hybrid parameters...20 Filtering techniques...21 Scale-limited surfaces...21
6 ii Gaussian filtering and others...22 Measurement preparation and instrument setup...25 Measurement sample preparation and instrument setup...26 Handling of calibration artefacts...26 Instrument calibration...26 Types of calibration...26 The effect of the magnification of the objective lens...28 The effect of optical zoom...29 Use of digital zoom...29 Mode of measurement...29 Fringe set up (levelling the sample)...29 Focus...30 Light source and its effect...30 Number of averaged measurements...31 Measurement optimisation settings...31 Signal to noise threshold...31 Data filling...31 Measurement speed...31 Environmental conditions...32 Positioning the instrument...32 Clean area...32 Draughts...32 Temperature gradients...32 Vibration...32 Measurement limitations when using coherence scanning interferometry...33
7 iii Sources of error in coherence scanning interferometry...33 Effect of optical properties of the surface being measured...34 Effect of the surface roughness of the surface being measured...35 Making measurements and interpreting results...37 Sample preparation and handling...38 Fixturing...38 Orientation...38 Metal coating of a sample...38 Sample replication...39 Location and number of measurements...39 Case study SOLADIM...39 Background and options...40 Significant effects...41 Good practice...44 Measurement processing...44 Appendices...47 Links to other useful sources of information...48 National and international organisations...48 Networks...49 Traceability...51 Training courses...51 International standards...52 Literature...54
8 iv List of tables Table 1. Variables investigated as part of the SOLADIM case study...40
9 v List of figures Figure 1. Schematic graph of amplitude against time showing constructive interference...4 Figure 2. Schematic graph of amplitude against time showing destructive interference...4 Figure 3. Constructive interference from one light source...5 Figure 4. A typical CSI design...6 Figure 5. Schematic of how to build up an interferogram on a surface using CSI. The vertical lines are intensity profiles at the image sensor...6 Figure 6. Commercially available coherence scanning interferometers. Clockwise from bottom left: Mahr, Phase Shift, Polytec, Taylor Hobson, Veeco, Fogale and Zygo...7 Figure 7. Schematic of a Mirau interferometer...8 Figure 8. Schematic of a Michelson interferometer...8 Figure 9. Example of the result of a profile measurement...12 Figure 10. Example of the result of an areal surface texture measurement...13 Figure 11. Illustration of the numerical aperture of a CSI objective lens...14 Figure 12. Profiles showing the same Ra with differing height distributions...15 Figure 13. A profile taken from a 3D measurement shows the possible ambiguity of 2D measurement and characterisation...16 Figure 14. An epitaxial wafer surface topographies in different transmission bands: (a) the raw measured surface; (b) roughness surface (short scale SL-surface) S-filter = 0.36 μm (sampling space), L-filter = 8 μm); (c) wavy surface (middle scale SF-surface) S- filter = 8 μm, F-operator; and (d) form error surface (long scale form surface), F- operator Figure 15. Result of the measurement of a grid type calibration artefact...27 Figure 16. A measurement of a step height artefact...28 Figure 17. The effect of field dependent dispersion on the measurement of a sinusoidal grating...33 Figure 18. A square wave grating that shows the batwing effect at the step edges...34
10 vi Figure 19. Variation in Sq with change in measurement variables...42 Figure 20. Change in surface topography with variation in measurement variable...43
11 GOOD MEASUREMENT PRACTICE There are six guiding principles to good measurement practice that have been defined by NPL. They are: The Right Measurements: Measurements should only be made to satisfy agreed and wellspecified requirements. The Right Tools: Measurements should be made using equipment and methods that have been demonstrated to be fit for purpose. The Right People: Measurement staff should be competent, properly qualified and well informed. Regular Review: There should be both internal and independent assessment of the technical performance of all measurement facilities and procedures. Demonstrable Consistency: Measurements made in one location should be consistent with those made elsewhere. The Right Procedures: Well-defined procedures consistent with national or international standards should be in place for all measurements.
12
13 Introduction 1 IN THIS CHAPTER Scope of this guide Introduction to coherence scanning interferometers
14 2 Chapter 1 Scope of this guide The purpose of this good practice guide is to assist users in the effective measurement and analysis of smooth surfaces using the technique of coherence scanning interferometry (CSI). The guide will cover the concepts of CSI, the route to repeatable and reliable measurement, an overview of appropriate analysis techniques and a guide to the interpretation of results. Throughout the guide the arbitrary definition of a smooth surface is one that has an approximately random distribution of heights with a roughness (Sz, see chapter 2) of less than 50 nm. Note that a further good practice guide (available in early 2008) will be concerned with the measurement of rough and structured surfaces. That guide will go into much more depth on the theory and practice of interferometry and should be consulted where non-smooth surfaces need to be measured. Semiconductor and Optical Layer Analysis and Definition using Interference Microscopy (SOLADIM) was a project funded by the MNT Manufacturing Initiative of the UK Department of Trade and Industry (2004 to 2007). The aim of the project was to develop measurement techniques and international specifications for surface texture measurement of epitaxial wafers and thin film coatings. Good practice guide no. 108 was compiled during the SOLADIM project to specifically look at the measurement of epitaxial wafers and thin film coatings, however, the principles can be applied to the measurement and characterisation of many flat and smooth surfaces. Throughout this guide we will concentrate on the use of coherence scanning interferometers. However, the generic principles of measurement good practice can be applied to many surface texture measuring instruments. During the formulation of this guide and development of the case study the Taylor Hobson Talysurf Coherence Correlation Interferometer (CCI) was used primarily. However, guidance is given that is entirely applicable to any CSI instrument. In 2002, the International Organization for Standardization (ISO) Technical Committee 213, dealing with Dimensional and Geometrical Product Specifications and Verifications, formed a working group (WG) 16 to address standardisation of areal (three dimensional) surface texture measurement methods. WG 16 is developing a number of draft standards encompassing definitions of terms and parameters, calibration methods, file formats and characteristics of instruments. Under this working group, a project team is developing standards for optical methods of areal surface texture measurement and one of these methods is CSI. Where possible the terms, definitions, parameters and measurement practices that are used in the draft standards have been adhered to in this guide. However, as this is a draft standard, it is subject to changes and additions. This guide will be updated to implement any changes and
15 3 Chapter 1 include any additions when the standard is formally published. The following terms that are listed in the draft standard are also used to refer to CSI: CPM CSM CR CCI MCM WLI WLSI SWLI VSI RSP RST HSI coherence probe microscope coherence scanning microscope coherence radar coherence correlation interferometry Mirau correlation microscope white light interferometry white light scanning interferometry scanning white light interferometry vertical scanning interferometry rough surface profiler rough surface tester height scanning interferometer Introduction to coherence scanning interferometers Basics of interferometry Interferometry is based on the idea that the amplitudes of two waves (for example, light, sound or water) with the same frequency will add to each other. When the two waves are in phase the result will sum to twice the amplitude (figure 1, assuming both have the same amplitude). When the two waves are out of phase by 180º the result will sum to zero amplitude (figure 2, again assuming both have the same amplitude). This adding and cancelling wave property is known as superposition and results in a set of dark and light bands known as interference fringes when viewed on a screen or through a microscope.
16 4 Chapter 1 a b c Wave a + Wave b = Wave c Figure 1. Schematic graph of amplitude against time showing constructive interference a b c Wave a + Wave b = Wave c Figure 2. Schematic graph of amplitude against time showing destructive interference In order to use superposition to construct a CSI using a single light source, a beam splitter can be used to create the two waves to be interfered. Typically in an interferometer, a wave is split into two parts, which travel different paths and the waves are then combined to create interference. When the paths differ by an even number of half-wavelengths, the superposed waves are in phase and constructive interference is observed, increasing the amplitude of the output wave. When they differ by an odd number of half-wavelengths, the combined waves are 180 out of phase and destructive interference is observed, decreasing the amplitude of the output. Anything that changes the phase of one of the beams by only 180 shifts the interference from a maximum to a minimum. A schematic of how the split beams produce constructive interference is shown in figure 3.
17 5 Chapter 1 Light Source Reference Constructive Interference Test Beam splitter Figure 3. Constructive interference from one light source Coherence scanning interferometry A schematic of a CSI is shown in figure 4. The upper beam splitter directs light from the light source towards the objective lens. The lower beam splitter in the objective lens splits the light into two separate beams. One beam is directed towards the sample and one beam is directed towards an internal reference mirror. The two beams recombine and the recombined light is sent to the detector. Due to the low coherence of the white light source, the optical path length to the sample and the reference must be almost identical, for interference to be observed. Note that coherence is the measure of the average correlation between the value of a wave at any pair of times, separated by a given delay. Temporal coherence tells us how monochromatic a source is. In other words, it characterises how well a wave can interfere with itself at a different time (coherence is discussed in detail in the follow up guide discussed at the beginning of this chapter). The detector measures the intensity of the light as the interferometric objective is actuated in the vertical direction (z axis) and finds the interference maximum. Each pixel of the sensor measures the intensity of the light and the fringe envelope obtained can be used to calculate the position of the surface. White light is used rather than monochromatic light because it has a shorter coherence length and, therefore, avoids ambiguity in determining the fringe order. Different instruments use different techniques to control the movement of the objective and to calculate the surface parameters. The accuracy and repeatability of the CSI measurement depend on many parameters including the control and linearity of the vertical actuator, the performance of the camera, the design of the metrology frame, the stability of the sample, the environment, etc.
18 6 Chapter 1 Figure 4. A typical CSI design As the objective lens is moved a change of intensity due to interference will be observed for each pixel when the distance from the sample to the beam splitter is the same as the distance from the reference mirror to the beamsplitter. If the objective is moved downwards (in figure 4) the highest points on the surface will cause interference first. This information can be used to build up a three dimensional map of the surface. Figure 5 shows how the interference is built up at each pixel in the camera array. Top Down Scan Direction Figure 5. Schematic of how to build up an interferogram on a surface using CSI. The vertical lines are intensity profiles at the image sensor
19 7 Chapter 1 There are many commercial coherence scanning interferometers available and this guide does not endorse a specific manufacturer. Figure 6 shows some examples of commercially available coherence scanning interferometers. Figure 6. Commercially available coherence scanning interferometers. Clockwise from bottom left: Mahr, Phase Shift, Polytec, Taylor Hobson, Veeco, Fogale and Zygo.
20 8 Chapter 1 Interferometer objective lenses Different designs of interferometer objective lens can be used for a CSI. Two of the most common are described in this section. In a Mirau interferometer the basic building blocks are a microscope objective lens, a reference surface and one semi-transparent optic (often called a beamsplitter). These are configured as shown in the figure 7. There are two paths from the light source to the detector. One beam reflects off the beamsplitter, travels to the reference mirror and then reflects back, travels through the beamsplitter, to the microscope objective lens and on to the detector. The other beam travels through the beam splitter, to the test surface, reflects back to the semi-transparent mirror and then reflects from the semitransparent mirror into the microscope objective lens and then the detector. Microscope Objective Lens Reference Surface Beamsplitter Test Surface Figure 7. Schematic of a Mirau interferometer A Michelson interferometer (see figure 8) is configured in a similar way to a Mirau with the exception that the reference surface is in a different position. This configuration is normally used at low magnification when the reference mirror is too large to be placed in the position shown in figure 7. Microscope objective lens Beamsplitter cube Reference surface Test surface Figure 8. Schematic of a Michelson interferometer
21 9 Chapter 1 This section has given a very brief introduction to interferometry including coherence scanning interferometry. To fully appreciate the concepts it may be necessary for the reader to have a fuller understanding of these principles than is given here. This may be achieved by reading the follow up generic good practice guide (mentioned at the beginning of this chapter) that will also be available in early 2008.
22 10 Chapter 1
23 Terms and definitions 2 IN THIS CHAPTER General terms used in this guide Areal surface texture parameters Filtering techniques
24 12 Chapter 2 General terms used in this guide This chapter outlines some of the common terms and principles used in this good practice guide. The chapter aims to assist the user with specialist terminology and promote understanding of basic surface metrology terms and definitions. Many of the general terms and definitions used in surface metrology can be found in an earlier good practice guide, number 37 (see Literature in the appendix) and it is recommended that the reader is familiar with that guide. A further guide is being developed that will cover coherence scanning interferometers in general. Surface profile measurement Surface profile measurement is the measurement of a line across the surface that can be represented mathematically as a height function with lateral displacement, z(x). With a stylus instrument profile measurement is carried out by traversing the stylus across a line on the surface. With a CSI, a profile is usually extracted in software after an areal measurement has been taken. Figure 9 shows the result of a profile measurement extracted from an areal measurement. nm Length = mm Pt = 1.89 nm Scale = 3 nm mm Figure 9. Example of the result of a profile measurement Areal surface texture measurement Areal surface texture measurement produces a three dimensional representation of a surface. The height data is represented as a height function in a plane, z(x, y). Figure 10 shows a typical representation of a smooth areal surface texture measurement. Sampling area The sampling area refers to the size of the xy plane in which an areal measurement is performed.
25 13 Chapter 2 Figure 10. Example of the result of an areal surface texture measurement Coherence scanning interferometry As we have seen in chapter 1 this is a surface topography measurement where the localisation of interference fringes during a scan of optical path length provides a way of determining a surface topography map. Numerical aperture The numerical aperture (NA) designates the spread of angles over which light illuminates a sample and the spread of angles over which light is accepted by the objective of the optical imaging system, for example, a CSI. With reference to figure 11, the NA is equal to the sine of the acceptance angle, α, multiplied by the refractive index of the surrounding medium. When operating in air, the refractive index is approximately one.
26 14 Chapter 2 Figure 11. Illustration of the numerical aperture of a CSI objective lens User defined variables User defined variables are options in the operating system of the CSI that can be changed or varied by the user thus influencing the measurement result. Examples of such variables include filtering settings and whether to use data filling techniques (see chapter 3). Smooth surface In this guide the term smooth surface refers to a surface with an approximately random height distribution and a maximum height (Sz) of less than 50 nm. Areal surface texture parameters In this section we will outline some of the areal surface texture parameters that are available for characterisation of surfaces. The parameters that are described here are applicable for use in the characterisation of smooth surfaces. There are additional parameters available, such as those to characterise relative volumes or material characteristics, and also those that would be useful in the depiction of bearing surfaces in preparation. The definition of these additional parameters can be found in the publications suggested in the Appendix and will be included in the ISO specification standards. Note that many of the parameters described here will be available in the software packages that come with commercial CSIs. Therefore, where a parameter may seem mathematically complex, for example the spatial parameters, often the
27 15 Chapter 2 user only needs a good understanding of the meaning of the parameter and may not need to know its exact derivation. Areal and profile parameters There are inherent limitations with 2D surface measurement and characterisation. A fundamental problem is that a 2D profile does not necessarily indicate functional aspects of the surface. For example, consider the most commonly used parameter for 2D surface characterisation, Ra (see NPL good practice guide number 37 for a description of profile parameters). Figure 12 shows the profiles of two surfaces, all of which return the same Ra value when filtered under the same conditions. It can be seen that the two surfaces have very different features and consequently very different functional properties. With profile measurement and characterisation it is also often difficult to determine the exact nature of a topographic feature. Figure 13 shows a 2D profile and a 3D surface map of the same component covering the same measurement area. With the 2D profile alone a discrete pit is measured on the surface. However, when the 3D surface map is examined, it can be seen that the assumed pit is actually a valley and may have far more bearing on the function of the surface than a discrete pit. Figure 12. Profiles showing the same Ra with differing height distributions The limitations of 2D surface measurement and characterisation have brought about the development of 3D surface measurement and characterisation. Three dimensional techniques give a better understanding of the surface in its functional state.
28 16 Chapter 2 Pits or valleys? Figure 13. A profile taken from a 3D measurement shows the possible ambiguity of 2D measurement and characterisation Amplitude parameters Amplitude parameters give information regarding the areal height deviation of the surface topography. There are seven parameters in the amplitude family that are described in this section. The root mean square value of the ordinate values within a sampling area, Sq The Sq parameter is defined as the root mean square value of the surface departures, z(x, y), within the sampling area, thus 1 2 Sq = z ( x, y) dxdy (2.1) A A where A is the sampling area, xy. Note that equation (2.1) is for a continuous z(x, y) function. However, when making surface texture measurements using CSIs (or indeed any surface texture measuring instrument), z(x, y) will be determined over a discreet number of measurement points. In this case equation (2.1) would be written as Sq = 1 N 1 M N i= 1 M j= 1 z 2 ij (2.2)
29 17 Chapter 2 where N is the number of points in the x direction and M is the number of points in the y direction. The equations for the other parameters below that involve an integral notation can be converted to a summation notation in a similar manner. The Sq parameter is the most common parameter that is used to characterise optical surfaces as it can be related to the way that light scatters from a surface. The arithmetic mean of the absolute height, Sa The Sa parameter is the arithmetic mean of the absolute value of the height within a sampling area, thus 1 Sa = z x y dxdy A (, ). (2.3) A The Sa parameter is the closest relative to the Ra parameter; however, they are fundamentally different and should not be directly compared. Areal, or S-parameters, use areal filters (see later section) whereas profile, or R-parameters, use profile filters. The Ra parameter is the most common profile parameter for purely historical reasons and the reader should note that Sq is a much more statistically significant parameter than Sa. Skewness of topography height distribution, Ssk Skewness is a measurement of the symmetry of the surface deviations about the mean reference plane and is the ratio of the mean cube value of the height values and the cube of Sq within a sampling area, thus Ssk = z ( x, y dxdy Sq A ). (2.4) 3 A The Ssk parameter describes the shape of the topography height distribution. For a surface with a random (or Gaussian) height distribution that has symmetrical topography, the skewness is zero. The skewness is derived from the amplitude distribution curve; it is the measure of the profile symmetry about the mean plane. This parameter cannot distinguish if the profile spikes are evenly distributed above or below the mean plane and is strongly influenced by isolated peaks or isolated valleys. This parameter represents the degree of bias, either in the upward or downward direction of an amplitude distribution curve. A symmetrical profile gives an amplitude distribution curve that is symmetrical about the centre line and an unsymmetrical profile results in a skewed curve. The direction of the skew is dependent on whether the bulk of the material is above the mean plane (negative skew) or below the mean plane (positive skew). Use of this parameter can distinguish between two surfaces having the same Sa value.
30 18 Chapter 2 As an example a porous, sintered or cast iron surface will have a large value of skewness. A characteristic of a good bearing surface is that it should have a negative skew, indicating the presence of comparatively few hills that could wear away quickly and relatively deep valleys to retain oil traces. A surface with a positive skew is likely to have poor oil retention because of the lack of deep valleys in which to retain oil traces. Surfaces with a positive skewness, such as turned surfaces, have high spikes that protrude above the mean plane. The Ssk parameter correlates well with load carrying ability and porosity. Kurtosis of topography height distribution, Sku The Sku parameter is a measure of the sharpness of the surface height distribution and is the ratio of the mean of the fourth power of the height values and the fourth power of Sq within the sampling area, thus Sku = z ( x, y dxdy Sq A ). (2.5) 4 A The Sku parameter characterises the spread of the height distribution. A surface with a Gaussian height distribution has a kurtosis value of three. Unlike Ssk this parameter can not only detect whether the profile spikes are evenly distributed but also provides a measure of the spikiness of the area. A spiky surface will have a high kurtosis value and a bumpy surface will have a low kurtosis value. This is a useful parameter in predicting component performance with respect to wear and lubrication retention. Note that kurtosis cannot differentiate between a hill and a valley. The maximum surface peak height, Sp The Sp parameter is defined as the largest peak height value from the mean plane within the sampling area. This parameter can be unrepresentative of a surface as its numerical value can vary so much from sample to sample. It is possible to average over several sampling areas and this will reduce the variation, but the value is often still numerically too large to be useful in many cases. However, this parameter will succeed in finding unusual conditions such as a sharp spike or burr on the surface or the presence of cracks and scratches that may be indicative of poor material or poor processing. The maximum pit height of the surface, Sv The Sv parameter is defined as the largest pit or valley depth from the mean plane within the sampling area. This parameter has the same disadvantages as the maximum surface peak height.
31 19 Chapter 2 Maximum height of the surface, Sz The Sz parameter is defined as the sum of the largest peak height value and largest pit or valley depth value within the sampling area. The Sp, Sv and Sz parameters give absolute values for features on the surface. They can be useful independently, but also can be used in conjunction with other parameters to describe surface topography more comprehensively. For instance, by examining both the Sq value and the Sz value, it may be possible to indicate whether the apparent roughness is due to isolated features or the overall surface roughness. Spacing parameters The spacing parameters describe the spatial properties of surfaces. These parameters are designed to assess the peak density and texture strength. These parameters are particularly useful in distinguishing between highly textured and random surface structures. Two parameters are used to characterise spatial properties given below. The auto-correlation length, Sal For this parameter it is first necessary to define the auto-correlation function as the correlation between a surface and the same surface translated by (tx, ty), given by z( x, y) z( x tx, y ty) dydy A ACF( tx, ty) = z( x, y) z( x, y) dxdy. (2.6) A The auto-correlation length, Sal, is then defined as the horizontal distance of the ACF(tx, ty) which has the fastest decay to a specified value s, with 0 s < 1. The Sal parameter is given by Sal = min tx ty. (2.7) For all practical applications involving smooth surfaces (as defined in this guide), the value for s can be taken as 0.2, although other values can be used and will be subject to forthcoming areal specification standards. For an anisotropic surface Sal is in the direction perpendicular to the surface lay. A large value of Sal denotes that that surface is dominated by low spatial frequency components, while a small value for Sal denotes the opposite case.
32 20 Chapter 2 Texture aspect ratio of the surface, Str The texture aspect ratio, Str, is a parameter used to identify texture strength, i.e. uniformity of the texture aspect. The Str parameter can be defined as the ratio of the fastest to slowest decay to correlation length, 0.2, of the surface ACF and is given by 2 2 min tx + ty Str =. (2.8) 2 2 max tx + ty In principle, Str has a value between 0 and 1. Larger values, say Str > 0.5, indicates uniform texture in all directions i.e. for no defined lay. Smaller values, say Str < 0.3, indicates an increasingly strong directional structure or lay. It is possible that the slowest decay ACFs for some anisotropic surfaces never reaches 0.2 within the sampling area. In this case, Str is invalid. Hybrid parameters The hybrid parameters are parameters based upon both amplitude and spatial information. They define numerically hybrid topography properties such as the slope of the surface, the curvature of outliers, and the interfacial area. Any changes that occur in either amplitude or spacing may have an effect on the hybrid property. The parameters have particular relevance to contact mechanics. The two hybrid parameters are mathematically quite complicated and are not presented here. They would not be expected to be of much use when characterising smooth surfaces.
33 21 Chapter 2 Filtering techniques Filtering is a way of extracting different spatial components, such as roughness, waviness and form error, from a measurement. Filtering is used to isolate specific spatial frequency bands relevant to different component information of the surface by decomposing a signal occurring in the spatial frequency or scale domain. Scale-limited surfaces Distinct from the 2D profile system, areal surface characterisation does not require three different groups (profile, waviness and roughness) of surface texture parameters as defined in ISO 4287 (1997). For example, in areal parameters only Sq is defined for the root mean square parameter rather than the primary surface Pq, waviness Wq and roughness Rq as in the profile case. The meaning of the Sq parameter depends on the type of scale-limited surface used. Two filters are defined, the S-filter and the L-filter. The S-filter is defined as a filter that removes unwanted small-scale lateral components of the measured surface such as measurement noise or functionally irrelevant small features. The L-filter is used to remove unwanted large-scale lateral components of the surface, and the F-operator removes the nominal form. The scale at which the filters operate is controlled by the nesting index. The nesting index is an extension of the notion of the original cut-off wavelength (see good practice guide number 37), and is suitable for all types of filters. For example, for a Gaussian filter the nesting index is equivalent to the cut-off wavelength, and for a morphological filter with a spherical structuring element, the nesting index is the radius of the spherical element. These filters are used in combination to create SF and SL surfaces. An SF surface (equivalent to a primary surface) results from using an S-filter and an F- operator in combination on a surface, and an SL surface (equivalent to a roughness surface) by using an L-filter on an SF surface. Both an SF surface and an SL surface are called scalelimited surfaces. The scale-limited surface depends on the filters or an operator used, with the scales being controlled by the nesting indices of those filters.
34 22 Chapter 2 Gaussian filtering and others A Gaussian filter is a good general-purpose filter and it is the current standardised approach for the separation of the roughness and waviness components from a primary surface. Both roughness and waviness surfaces can be acquired from a single filtering procedure with minimal phase distortion. The weighting function of an areal filter is the Gaussian function given by (, ) s x y π x y α λcxλcy α λ cx λ cy exp +, λcx x λcx, λcy y λcy = 0 otherwise (2.9) where x, y are the two-dimensional distance from the centre (maximum) of the weighting function, λ c is the cut-off wavelength, α is a constant, to provide 50% transmission characteristic at the cut-off λ c, and α is given by ln 2 α= π. (2.10) With the separability and symmetry of the Gaussian function, a two-dimensional Gaussian filtered surface zxycan (, ) be performed by convoluting two one-dimensional Gaussian filters through rows and columns of a measured surface z'( x, y ) (2.11) zxy (, ) = z'( xy, ) ( z'( x n, y n) sn ( ) sn ( )) Figure 14 shows a raw measured epitaxial wafer surface (a), its short scale SL surface (roughness) (b), middle scale SF surface (waviness) (c) and long scale form surface (form error surface) (d) by using Gaussian filtering with an automatic correct edged process (which has been integrated by some CSI instrument software).
35 23 Chapter 2 Figure 14. An epitaxial wafer surface topographies in different transmission bands: (a) the raw measured surface; (b) roughness surface (short scale SL-surface) S-filter = 0.36 μm (sampling space), L-filter = 8 μm); (c) wavy surface (middle scale SF-surface) S- filter = 8 μm, F-operator; and (d) form error surface (long scale form surface), F-operator. The international standard for the areal Gaussian filter (ISO ) is being developed by Technical Committee 213 of ISO (the areal Gaussian filter has been widely used by almost all instrument manufacturers). It has been easily extrapolated from the linear profile Gaussian filter standard (ISO 11562) into the areal filter by instrument manufacturers for at least a decade and allows users to separate waviness and roughness in surface measurement. For multi-processing surfaces (surface topography is a combination of initial rough machining with later ultra precision processing), the roughness data has differing degrees of precision that contains some very different observations or outliers. In this case, a robust Gaussian filter (based on the maximum likelihood estimation) can be used to suppress the influence of the outliers. Nowadays, the robust Gaussian filter can also be found in most CSI instrument software.
36 24 Chapter 2 It should be noted that the Gaussian filter is not applicable for all functional aspects of a surface, for example, in contact phenomena, where the upper envelope of the surface is more relevant. A standardised framework for filters has been established, which gives a mathematical foundation for filtration, together with a toolbox of different filters. Information concerning these filters has been published as a series of technical specifications (ISO/TS series), to allow metrologists to assess the utility of the recommended filters according to applications. So far only profile filters have been published, including, the following classes of filters: Linear filters: the mean line filters (M-system) belong to this class and include the Gaussian filter, spline filter, and the spline-wavelet filter. Morphological filters: the envelope filters (E-system) belong to this class and include closing and opening filters using either a disk or a horizontal line. Robust filters: filters that are robust with respect to specific profile phenomena such as spikes, scratches and steps. These filters include the robust Gaussian filter and the robust spline filter. Segmentation filters: filters that partition a profile into portions according to specific rules. The motif approach belongs to this class and has now been put on a firm mathematical basis. Filtering is a complex subject that will probably warrant a good practice guide of its own following the introduction of the ISO series of specification standards. The user should consider filtering options on a case-by-case basis but the simple rule of thumb is that if you want to compare two surface measurements, it is important that both sets use the same filtering methods and nesting indexes. Future standards will address default nesting indexes but at the time of writing there is still much debate in the standards committees as to their values.
37 Measurement preparation and 3 instrument setup IN THIS CHAPTER Measurement sample preparation and instrument setup Measurement optimisation settings Environmental conditions Measurement limitations when using coherence scanning interferometry
38 26 Chapter 3 Measurement sample preparation and instrument setup In this chapter, an overview of typically available user defined variables is given, and a method for selection of appropriate measurement settings and protocols is offered. The terms used in this chapter are generic and may differ in their description depending upon the instrument being used. Handling of calibration artefacts Calibration artefacts should be stored and cleaned in accordance with the manufacturer s guidelines. Cleaning methods are generally dependent upon the material of the artefacts. If there is any doubt as to the proper handling methods, advice should be sought from the manufacturer or supplier. Cleaning materials should be non-abrasive and non-corrosive to the surface. Typically a fluid such as solvent used with a non-abrasive, non-shedding cloth can be used, or a clean air supply to remove any loose contaminants (note that care must be taken as to which solvent to use with a given sample seek the advice of the manufacturer of the sample or the material supplier). Calibration artefacts should be stored alongside the instrument in a stable environment with respect to temperature and humidity. Handling of the artefacts should be kept to a minimum, and protective gloves or handling devices should be used to prevent thermal transfer and contamination. Instrument calibration Calibration of the CSI is an important factor in producing reliable and repeatable measurements. It is important to calibrate the instrument whenever a major adjustment has been made to the instrument or to the environment in which it is housed. It is recommended that a calibration schedule be written into the overall measurement protocol for the instrument. The frequency of calibration is dependent upon a number of factors such as environment of use, instrument stability and any regulatory requirements particular to the application. Types of calibration A comprehensive but not exhaustive list of available types of calibration artefacts for various CSI instruments is given in this section. It is important to note that at the time of writing there are only draft specification standards for calibrating areal surface texture measuring instruments. Indeed, there is no clear traceability route for any areal measurements. Therefore, it is only possible to check that the instrument compares to the calibration value given by the instrument manufacturer and that measurements are repeatable. Where possible surface profile measurements can be calibrated using artefacts described in ISO
39 27 Chapter 3 (2002) as these measurements can be traceable to national or international standards. NPL good practice guide number 37 describes surface profile calibration in detail for a stylus instrument and many of the calibration techniques can be applied to profiles extracted from areal measurement data. Lateral or spatial calibration Lateral or spatial calibration of a CSI determines the characteristics of the x and y measurement capability and allows for a correction to be applied. Lateral or spatial calibration is generally achieved by measuring a calibrated pattern on an artefact, for example a grid or series of concentric circles. This calibration serves to accurately set the instrument s basic magnification, which is a function of the optical sensor (camera) and associated optical elements. The result of the measurement of a grid type calibration artefact is shown for example in figure 15. Figure 15. Result of the measurement of a grid type calibration artefact Vertical calibration Vertical calibration allows for the correction of any unwanted motion effects in the vertical (z) measuring axis. This may include gain errors, periodic scanner effects (such as from gears or motors) as well as overall nonlinearities. Vertical calibration is generally achieved through the use of a step height of calibrated dimension. Ideally the step height used should be as close to the height that you are routinely measuring as is available such that the calibration is localised to the operating area for any particular sample. Note that some commercial CSIs incorporate a separate displacement measuring interferometer to measure the motion of the z axis actuator. These systems should not require step calibration, although a step should ideally be used for verification purposes. Step height calibration for profile measuring instruments according to ISO specification standards is described in NPL good practice guide number 37. This calibration can be applied to the vertical calibration of areal instruments although it is better to make an areal measurement of the step as opposed to a single line scan. If an areal step height measurement is carried out, least squares planes need to be fitted
40 28 Chapter 3 to the data where least squares lines would have been fitted for profile data. Figure 16 shows the areal measurement results of a step height artefact. Alpha = 25 Beta = nm nm nm Figure 16. A measurement of a step height artefact Form correction Form correction serves to correct errors associated with the reference optics or in the objective lens assembly. Form correction is generally achieved through single or multiple measurements taken of a reference flat surface. By maximising the area of the artefact over which measurements are taken for performing calibration, the effects of noise and residual contamination can be minimised and the quality of the calibration can be enhanced. The effect of the magnification of the objective lens The magnification of the objective lens selected for any measurement has an effect on the measurement result. Changing the magnification alters the lateral resolution and slope handling in the following ways: Lateral resolution or spacing - for any particular instrument the lateral resolution will generally increase with increase in magnification. Slope handling the higher the numerical aperture of the lens the higher the surface slope handling capabilities. Instruments are available with varying number and sizes of pixel arrays; this combined with the magnification can affect the lateral resolution and overall field of view. This should be carefully considered when selecting the correct lateral resolution for any particular application. Typical pixel arrays can range between pixels and pixels. It should be noted that some mathematical analysis techniques (for example filtering methods) work optimally with square pixel arrays.
41 29 Chapter 3 For any particular instrument a change in the field of view can be achieved either by a change of objective lens, or by utilising an optical or a digital zoom. The effect of optical zoom Optical zoom is a process where a measurement area is altered whilst utilising the same pixel array. There are two approaches to achieving a change in optical zoom without a change of objective lens. Firstly the physical introduction of a field of view multiplier optic and secondly the use of a zoom lens. A zoom lens gives the benefit of versatility in the system, giving a larger range of available measurement areas. Using extra optics to adjust the field of view will generally not improve the slope handling capabilities of the instrument, but will change the effective pixel size. Increasing the effective pixel size is especially useful when examining narrow features, where oversampling may reduce the noise present in calculations such as linewidths or tilts. This function should be treated as a change of lens and the instrument will need to be re-calibrated. This is an especially important consideration when using a zoom lens. Use of digital zoom Digital zoom is a process where the measurement area is altered whilst keeping the pixel resolution constant. A digital zoom simply uses a localised area of the pixel array (on some instruments the full array of data is maintained whilst on others this data is lost). This function has the benefits of being able to focus on an area of interest and also reducing processing time. This function can be used without the need for re-calibration of the instrument. Mode of measurement Most commercial instruments offer a number of modes of measurement within the instrument s capability. The choice of modes can affect the resolution of measurement through pixel binning and other averaging or filtering techniques. Within the scope of this document, where smooth surfaces are concerned, it is desirable to maximise the spatial resolution of the measurement and, therefore, the mode of measurement should be selected accordingly. Other modes of measurement allow the user to choose whether phase only, coherence only, or both are used to create the map of the surface. The choice of measurement mode can be fairly complicated and the user should consult the instrument manual or contact the manufacturer where there is doubt. Fringe set up (levelling the sample) Fringe set up of the sample can affect the measurement outcome; the accuracy of levelling can be determined by the fringe pattern visible during set up. The fringe set up will depend
42 30 Chapter 3 upon the nature of the surface. For flat, featureless surfaces it is ideal to have the sample as level as possible, thereby with the fringe pattern optimised (one to two fringes visible, known as nulled fringes ). In the case of curved surfaces it is important to ensure that the centre of the fringe pattern is centred over the main area of interest if possible. The number of fringes visible will have an effect on the measurement result and should be investigated for any particular sample to give an appropriate levelling target. To ensure good measurement practice, if a series of similar samples are under investigation, it is important to be consistent in measurement set up to ensure repeatable results. To aid in levelling the user may use an automatic tip/tilt levelling stage (available on some instruments or as an option). Focus For high accuracy CSI, it is necessary that every pixel of the sample passes through the focus position during the scan, and that in fact the scan starts before fringes are visible on a given pixel and does not end until all fringes have passed out of the field of view. The scan length required to achieve this is dependent on the bandwidth of the light used and the numerical aperture of the objective. When combining phase with coherence information, focus can be especially important, and some instruments use autofocus is to achieve the most consistent results. Light source and its effect The intensity of most light sources used in CSI can be varied. It is important to set the light intensity at an optimum level; this will vary from system to system and from sample to sample. It should be noted that a change in light intensity can alter measurement results and this should be taken into account when formulating measurement protocols. It should also be noted that consistent setting of light intensity will improve repeatability of measurement. If the light source intensity is too high saturation of the detector can lead to missing data and similarly, low sample reflectance can cause problems with measurement signal and, therefore, measurement data may not be complete. Typically best results are obtained when the intensity during a scan approaches, but does not exceed, the saturation limit this will give the highest signal to noise ratio. Consideration should be given to type of light source and the wavelength of the light used. Ideally the light source should be optimised for the material under investigation. Different commercial instruments have different sources with different bandwidths. The user should consult the instrument manual or the manufacturer when establishing which source or bandwidth is most suitable for which material.
43 31 Chapter 3 Number of averaged measurements Using a number of repeated measurements and calculating an average can minimise the effects of system noise and environmental changes. By increasing the number of averaged measurements, an improvement in repeatability may be achieved. Choosing the number of repeat measurements is a compromise between noise reduction and time of measurement. Experience gained during the SOLADIM project suggested that the optimum number of averaged measurements is four, although different surfaces may require a different number of measurements and there may be time constraints. The number of averaged measurements becomes increasingly important as one approaches the noise floor of the instrument. Changing the number of averaged measurements can cause significant changes in calculated results. If the instrument noise is random, the noise floor will reduce as the square of the number of measurements. Measurement optimisation settings All CSI instruments have settings to optimise a measurement. These will depend on the measurement technique used and the system used. Some of the more common settings are briefly discussed below. Signal to noise threshold This setting is generally used to remove any obviously incorrect data. The incorrect data can be from a variety of sources such as dirty optics or stray light. This option is often adjusted for unusually rough samples and would probably not be required when measuring a smooth surface. Data filling Data filling is often used when there is missing data. The nature of the surface and the implications of the data fill process should be studied and understood before this setting is selected. Measurement speed On some instruments it is possible to change the speed of measurement. This can allow the undersampling of the fringe envelope, sacrificing some repeatability for measurement speed. Speeds can from around 5 mm s -1 to 100 mm s -1. Note that changing the scan speed will also effect the vertical resolution so care must be taken.
44 32 Chapter 3 Environmental conditions Positioning the instrument The instrument hardware should be installed with consideration given to the surroundings in which it will operate and the manufacturer s specifications. The overall accuracy of the measurement results can be influenced by environmental conditions, particularly: draughts, vibration and the rate that the ambient temperature changes. The following items must be considered when positioning the instrument. Clean area All forms of airborne particle can be detrimental to the performance of a CSI but particularly smoke, dust and airborne oil particles. Ideally the instrument should be located in a clean environment and clean room clothing should be worn by all personnel in the room. It may be necessary to house the CSI in a dedicated enclosure. Draughts Avoid subjecting the instrument to draughts and airborne vibration where possible. Avoid placing the instrument directly under or next to air conditioning vents or laminar flow hoods. An environmental enclosure can be used to reduce the effect of draughts around the component measurement area. Temperature gradients Avoid positioning the instrument in areas that have a high temperature gradient or rapid temperature changes, and avoid positioning near windows or skylights where sunlight may fall on the instrument. Thermal stability will enhance repeatability of measurements over extended periods of time. Vibration Both acoustic and ground based vibration is particularly detrimental for the measurement of surface texture. It is recommended that all sources of vibration be removed. Where possible, instruments should be placed on the ground floor of a building to maximise stability. It is also important that cables should be fixed correctly to avoid transmission of vibration. Cables should not be bundled together to form a single, rigid mass as this will form a solid pillar that will transmit vibration. Some instruments are supplied with dedicated anti-vibration mounts.
45 33 Chapter 3 Measurement limitations when using coherence scanning interferometry This section briefly describes some of the potential sources of error when using a CSI. The error sources described here are only those that are inherent to CSI and do not include such things as environmental effects or mistakes in set-up and use by the operator. A further source of error will be in the calibration of the instrument (see earlier section). Some of the sources of error discussed in this chapter will not be present when measuring smooth surface topography (for example, the batwing effect) but they are included here for completeness. Sources of error in coherence scanning interferometry Ghost steps Stepped artefacts have been reported when measuring perfectly flat objects. Errors of this kind are commonly referred to as ghost steps. These steps usually correspond to a 2π phase jump or a surface height error of around half the mean wavelength. More generally phase jumps of this magnitude are referred to as 2π errors and can be thought of as a misclassification of fringe order. In these cases the error is due to a field dependent dispersion that is inherent in the geometry of some types of interferometers. Note that ghost steps are only present when combining phase with coherence information. Field dependent dispersion A similar dispersive effect to the ghost steps makes CSI sensitive to surface gradient. Tilt dependent dispersion is often the cause of 2π errors in CSI measurements even when the tilt is small compared to the NA of the objective. If errors of this kind are present then 2π errors, for example, can appear at regular intervals on regular sinusoidal profiles (see for example figure 17). μ m µm µm μm Figure 17. The effect of field dependent dispersion on the measurement of a sinusoidal grating
46 34 Chapter 3 A combination of field and tilt dependent dispersion is also responsible for errors of similar appearance to the batwing effect. In contrast with regular batwing errors, the presence of these phase jumps depends systematically on position and generally increases in severity toward the edge of the field of view. This effect also depends strongly on the polarity of the discontinuity. It is noted that (depending on the height retrieval algorithm used) in extreme cases the dispersive batwing effect can result in errors that propagate and result in a corresponding error in step height measurement. The batwing effect The batwing effect is a well-known example of an error that is observed around a step discontinuity especially for the case of a step height that is less than the coherence length of the light source. The batwing effect is so called because of the shape of the error (see for example figure 18) and it is usually explained as the interference between reflections of waves normally incident on the top and bottom surfaces following diffraction from the edge. CSI does not give the correct surface height at the positions close to the step even if the step height is significantly greater than the coherence length. Note that this effect would not be expected when measuring a smooth surface but must be considered when using a step height artefact to calibrate the instrument. n m nm µm μm Figure 18. A square wave grating that shows the batwing effect at the step edges Effect of optical properties of the surface being measured Dispersive effects of the kind mentioned are clearly a function of the quality of the optical system, however, the optical properties of the surface to be measured are also a potential source of error. Different materials exhibit different phase changes on reflection, and depending on the processing algorithms used, these will affect the surface height measurement. Phase changes are typically less than 45 degrees (corresponding to surface height errors of less than 30 nm) but can combine with dispersive effects to give 2π errors as discussed previously. This type of error is only a problem when two or more materials with different optical properties are present in a sample.
47 35 Chapter 3 Effect of the surface roughness of the surface being measured Estimates of surface roughness derived from CSI can differ significantly from other measurement techniques. The surface roughness is generally over estimated by CSI and this can be attributed to multiple scattering. Although it may be argued that the local gradients of rough surfaces exceed the limit dictated by the NA of the objective and, therefore, would be classified as beyond the capability of CSI instrumentation, measured values with high signal to noise ratio are often reported in practice. If, for example, a silicon V-groove (smooth walls, with an internal angle of degrees) is measured, a clear peak with its apex at the bottom of the profile is observed. This is due to multiple reflections (scattering) from the sidewalls. Although this example is specific to a highly polished V-groove fabricated in silicon it is believed to be the cause for over estimation of surface roughness since a roughened surface can be considered to be made up of randomly oriented grooves with varying internal angles. Note that the effect of surface roughness is usually only a problem when using coherenceonly modes and can be solved by combining phase and coherence modes.
48 36 Chapter 3
49 Making measurements and 4 interpreting results Sample preparation and handling IN THIS CHAPTER Case study SOLADIM
50 38 Chapter 4 Sample preparation and handling When using any surface texture measuring instrument samples for measurement must be clean and free from grease, smears, fingerprints, liquids and dust. Handling procedures must ensure that the sample is not contaminated with any contaminants, and handling should be kept to a minimum prior to measurement. A period of sample acclimatisation may also be needed. Any cleaning protocol should note that any fluids used in cleaning may contain contaminants which can leave a residue on the surface; this will affect the measurement detrimentally. Any contaminants may become part of the measured data if present on the surface, or result in missing data. It is important that care be taken when transporting sample surfaces for measurement. In particular the use of polythene sample bags is not recommended since the internal surfaces are often coated with a release agent, which can be transferred to the sample surface. Use of either lint free paper bags or Fluoroware containers overcomes this problem. Fixturing It is difficult to give comprehensive guidance on fixturing methods because solutions will depend on the geometry and mass of individual samples. Problems may be encountered by use of any method of fixturing other than the component s own weight. When using nonpermanent adhesives such as adhesive tape or gels for fixturing, scope for movement during measurement is introduced through factors such as creep. When introducing external forces to aid fixturing, the possibility of sample distortion may be encountered and, therefore, the measurement data altered. In addition, use of a vacuum method of fixturing may introduce vibration. Fixturing is essential when stitching together multiple measurements to prevent random movement as the translation stage is scanned. Loosely fixtured parts may also be a source of vibration. Orientation The orientation of any given sample may affect the resulting measurement data. Care should be taken that similar samples are measured in the same orientation to ensure repeatability. The lay of the surface texture and the light reflectance may have an effect on the measurement result (also some cameras have different frequency responses in different directions). Metal coating of a sample The effects of dissimilar materials (see chapter 3) can be avoided by coating the sample with a single material film, for example gold or chromium. When using this method one must ensure that an even coating is deposited over the entire sample.
51 39 Chapter 4 Sample replication Sometimes it is difficult to access a sample for measurement. For example, the sample may be too large to mount on the CSI, you may want to measure inside a cylinder or the sample may have a complex geometry that is not easily accessible by the CSI. For such samples a replication of the surface can be made using a suitable replication compound. These are usually based on polymer material and are widely available commercially. Note that as many of the replication samples are relatively soft polymers, care must be taken to avoid introducing unwanted form into the replica. Some studies have shown that replication compounds can reproduce the surface texture of a sample to within tens of nanometres. Location and number of measurements Most components will fall under the guidelines of a particular specification standard where measurement location and quantity are concerned, if there is no comprehensive guide to provide this information for a given sample, it is imperative to establish the required protocol to ensure statistical relevance in the data collected. The procedures in this guide are aimed at a routine inspection environment; greater flexibility may be used when taking measurements for process improvement or research situations. The important factor would always be consistency in protocol to ensure repeatability. Case study SOLADIM The following section is a case study that is based on work carried out as part of the SOLADIM project. A number of experiments were carried out to determine the effect of user defined variables on the measurement result when measuring semiconductor wafers. Semiconductor substrates and epitaxial wafers (a generally used term in the industry) are usually very smooth samples (Sa 0.1 nm to 1 nm) with very low values of bow and warp (of the order of micrometres across a sample). Semiconductor substrates are thin (normally 0.1 mm to 1 mm total thickness), can be any size from part wafers up to circular 300 mm diameter wafers, and are often mechanically quite fragile. However, most semiconductor substrates are good samples for CSI measurements because they are highly reflective in the visible region of the spectrum. Those materials that are transparent in the visible region of the spectrum have high refractive indexes and thus give more than adequate signal. Samples must be smooth enough to permit photolithographic definition of features in the region of tens of nanometres. Semiconductor materials are single crystals and can display features that are strongly orientated thus it is important to make a record of the lateral orientation of the sample and
52 40 Chapter 4 keep this consistent during a series of measurements. The lateral orientation of the wafer is normally indicated by a flat (usually two flats of differing lengths) or a notch ground into the periphery of the wafer. a) Because samples are thin they are often of low mass. This can create problems due to environmental factors (particularly air flow) that cause the wafer to physically move or vibrate on the stage thus producing noisy or unobtainable measurements. b) The location and quantity requirements for measurement are stated in the SEMI specification standards. Background and options A study was conducted to determine the effects of user defined measurement variables on measurement result. The study was formulated employing design of experiments to create a factorial study to determine the significant effects of some of the possible user defined variables. The study was carried out using the Taylor Hobson Talysurf Coherence Correlation Interferometer (CCI) and, therefore, the options investigated are specific to that instrument. This case study does, however, show how statistical techniques can be effectively and efficiently employed to determine good practice for any given surface. In the case of this study good practice was deduced through comparison of measurement results collected from an AFM that is an established technique in the measurement and characterisation of semiconductor materials. The following user defined variables were investigated. Variable Low Condition (-1) High Condition (+1) Intensity 40% 50% Fringe Set Up 4+ fringes 1 to 2 fringes Multiple measures Off 4 Special options Off Reduced threshold (70%) Post Process Off On Peak Only Off On Table 1. Variables investigated as part of the SOLADIM case study The high and low conditions were set at levels deemed to be feasible in routine use of the CCI. The recommendation from the manufacturer for light intensity is about 50%; other
53 41 Chapter 4 interferometers recommend that the light level be set just below light saturation. Very little adjustment of the light intensity is needed to shift from 40% to 50%; therefore, the light intensity levels at 40% and 50% have been investigated to determine if there is a marked difference in measurement result. Fringe set up refers to the degree of levelling of the sample, the more levelled the sample, the fewer the fringes used to measure the surface, the low condition was set to be four or more fringes, the typical number of fringes used in this case study during the course of the experiment was four to six. The high condition was to ensure good levelling of the surface so that only one to two fringes were present on the surface during measurement. The effect of this difference on the measurement outcome was investigated. Multiple measures refer to the software option of averaging a number of multiple measurements (in multiples of two). The low condition was set to a single measurement; the high condition was set to four measurements, to determine the impact of multiple measurements on measurement outcome. Special options refer to the software s threshold for signal to noise. The low condition threshold was set as 100%, and the thresholding tool was effectively turned off. The high condition was set as 70% threshold, to determine if the minimum incremental change in the threshold tool would produce a variation in measurement outcome. Post process is an option in the measurement window of the CCI control software. Selecting the post process option changes the way in which the software handles the data, where post process is selected, the data is all exported for analysis and no data mining is undertaken until the analysis process, ensuring higher resolution. The effect of this option is thought to affect the results of various samples differently. Therefore, it was deemed reasonable to investigate the impact of this on measurements of samples typical to those under investigation during the SOLADIM project. Peak only is another option within the measurement window of the CCI control software, the peak only option ensures that only the highest peak of intensity of the fringes is recorded and processed. The impact of this option was investigated. All measurements in this study were completed on gallium arsenide substrates. Significant effects Figure 19 and figure 20 shows the change in measurement outcome with change in measurement variable. By using statistical analysis techniques the variables that produced significant effects on the measurement outcome were determined, and from this model a suitable measurement protocol was derived. This ensured repeatable measurement of samples operator to operator and project partner to project partner. In addition to this, depending upon
54 42 Chapter 4 the nature of the sample and the measurement, it may be advisable to complete a gauge R&R study Sq (nm) Run Figure 19. Variation in Sq with change in measurement variables 32
55 43 Chapter 4 High Intensity 1-2 Fringes 1 x Measures Special ops off Post Process off High Intensity 4+ Fringes 1 x measures Special ops off Post Process off Low Intensity 4 + Fringes 4 x Measures Special ops off Post Process on Low Intensity 4+ Fringes 1 x Measures Special ops off Post Process on Low Intensity 1-2 Fringes 1 x Measures Special ops off Post Process on Figure 20. Change in surface topography with variation in measurement variable
56 44 Chapter 4 Good practice Following analysis of measurements using statistical evaluation of significant effects, the following were selected as best practice guidelines to be used during measurement of samples: Intensity The intensity should be set as close to 40% as possible, the study showed that this was the optimum intensity level for measurements of the samples studied. Fringe set up/levelling The study showed that for certain 3D surface texture parameters, better results were gained when care was taken to level the sample so that one to two fringes were visible prior to measurement. The added benefit of this is the reduction in measurement time. Multiple measures Employing multiple measures and averaging over four measurements was shown to have a positive effect on measurement outcome. Employing larger numbers of multiple measures improves the outcome further, however, the benefit of doing this is outweighed by the large increase in measurement time. Special options Employing the special options function and reducing the signal to noise ratio, did not have a significant effect in this study. It is deemed that the optimum for measuring the samples in question would be to have maximum threshold with special options off. Post process The optimum setting was shown to have the post process function turned on. Peak only The peak only option should always be turned off when measuring samples; this was shown to have the biggest effect on measurement outcome. Measurement processing Before altering the raw measurement data in any way, it is always good practice to save a copy of the data, and also visually check for potential anomalies such as optical spikes or an unacceptable percentage of missing data. The first process to apply to data is form removal where applicable (tilt, cylindricity, sphericity, bow and warp). This will remove simple geometrical form in the measurement data so that the functional surface can be examined.
57 45 Chapter 4 With the use of mathematical filters it is possible to manipulate the data in order to remove/separate out waviness and roughness. Care should be taken when applying such filters as there is the possibility of losing all data relating to function through over processing the data. As a rule the best practice would be to use no filtering following the simple form removal for smooth surfaces. Where filters are deemed necessary extreme caution should be used.
58 46 Chapter 4
59 Appendices 5
60 48 Appendices Links to other useful sources of information National and international organisations National Physical Laboratory The National Physical Laboratory (NPL) is the UK s National Measurement Institute and is a world-leading centre of excellence in developing and applying accurate measurement standards, science and technology. For more than a century NPL has developed and maintained the nation s primary measurement standards. These standards underpin an infrastructure of traceability throughout the UK and the world that ensures accuracy and consistency of measurement. NPL ensures that cutting edge measurement science and technology have a positive impact in the real world. NPL delivers world-leading measurement solutions that are critical to commercial research and development, and support business success across the UK and the globe. Good measurement improves productivity and quality; it underpins consumer confidence and trade and is vital to innovation. NPL undertakes research and shares its expertise with government, business and society to help enhance economic performance and the quality of life. NPL s measurements help to save lives, protect the environment, enable citizens to feel safe and secure, as well as supporting international trade and companies to innovation. Support in areas such as the development of advanced medical treatments and environmental monitoring helps secure a better quality of life for all. NPL is a world-leading centre in the development and application of highly accurate measurement techniques. As the UK's national standards laboratory, NPL underpins the National Measurement System (NMS), ensuring consistency and traceability of measurements throughout the UK. NPL offers a unique range of measurement services, contract research, consultancy and training services. Other areas of expertise include the design and characterisation of engineering materials, and mathematical software, especially its application to measurement and instrumentation. For more information on the wide range of metrology services, facilities and research work carried out at NPL either visit the NPL web site at or contact the NPL Helpline: Tel: , Fax: , [email protected]
61 49 Appendices National Institute of Standards and Technology (NIST) NIST is the equivalent of NPL in the United States of America. The NIST web site is and often contains documents relevant to this guide in.pdf format. EURAMET - European Association of National Metrology Institutes The European Association of National Metrology Institutes (EURAMET) is the Regional Metrology Organisation (RMO) of Europe. On 1st July 2007 EURAMET e.v. became the successor to EUROMET the previous RMO which had coordinated European metrology needs for over 20 years. EURAMET coordinates the cooperation of National Metrology Institutes (NMIs) of Europe in fields like research in metrology, traceability of measurements to the SI units, international recognition of national measurement standards and of the Calibration and Measurement Capabilities (CMC) of its members. EURAMET currently has 32 members (including NPL), 5 associate members and operates 12 Technical Committees, one for each physical metrology subject field, plus committees dealing with interdisciplinary metrology and quality matters. More details and information about the many cooperative projects run by EURAMET and its members can be found on the EURAMET web site: Networks Dimensional Metrology Awareness Club (DMAC) and the Engineering Measurement Awareness Network (EMAN) The EMAN network is a means of encouraging knowledge exchange between industry, academia and NPL. In collaboration with other networks, both within NPL and elsewhere in the UK, it aims to address the measurement issues in industry and manufacturing. The network comprises four Special Interest Groups: Dimensional - covering coordinate and machine tool metrology, form and surfaces (known as DMAC) Force, Torque & Hardness Pressmet - covering pressure and vacuum measurement Weighing & Density The activities of the network are steered by members. Although most meetings are related to one of the above special interest group titles, events have been held covering topics ranging
62 50 Appendices from data acquisition, exporting to the US, and materials testing. The purpose of the network is: to facilitate information flow to enable solutions for engineering measurement problems to encourage collaborations between NPL, equipment manufacturers and suppliers, and people making engineering measurements for members to influence the direction of the National Measurement System Engineering Measurement Programme at NPL. EMAN is an industry-focused club. The club is managed by NPL on behalf of the DIUS and has the following objectives: to provide a focused platform for interaction across all the technical areas covered by the Engineering Measurement Programme; to enable members to learn about the latest developments in their own as well as related areas of dimensional metrology; to provide a mechanism to encourage and facilitate interaction and exchange of ideas with other member organisations and to give members the opportunity to provide input to, and influence the development of future NMS programmes. For further information visit the EMAN web site at Software Support for Metrology Programme (SSfM) SSfM is a metrology-focused programme comprising projects designed to meet the requirements of National Measurement System programmes. The overall aim of the SSfM Programme is to tackle a wide range of generic issues, some of which are problems in metrology that require the application of established software engineering practices, whilst others require advances in mathematics, software engineering or theoretical physics. The programme, thus, includes work in metrology, mathematics, software and theoretical physics, with strong links between the various disciplines. The SSfM Club is aimed at users and suppliers of metrology software, giving them a say in the direction of the Programme. It is the focal point for the distribution of general information arising from the Programme. Further details can be found at
63 51 Appendices Traceability Traceability in measurement is the concept of establishing a valid calibration of a measuring instrument or measurement standard, by a step-by-step comparison with better standards up to an accepted or specified standard. In general, the concept of traceability implies eventual reference to an appropriate national or international standard. The National Physical Laboratory is the United Kingdom's national measurement institute. It operates at the heart of the National Measurement System (NMS) which is the infrastructure designed to ensure accuracy and consistency in every physical measurement made in the UK. Chains of traceability link UK companies measurements directly to national standards held at NPL. For the majority of industrial applications, companies can establish a link to national measurement standards through the calibration and testing services offered by United Kingdom Accreditation Service (UKAS) accredited laboratories, which are in turn traceable to NPL. However, for challenging or novel measurements to the highest standards of accuracy, which are not catered for by UKAS accredited laboratories, NPL can often provide a traceable measurement solution directly to industry. UKAS is the sole national body recognised by government for the accreditation of testing and calibration laboratories, certification and inspection bodies. A not-for-profit company, limited by guarantee, UKAS operates under a Memorandum of Understanding with the government through the Department of Innovation, Universities and Skills. UKAS accreditation demonstrates the integrity and competence of organisations providing calibration, testing, inspection and certification services. Further information on UKAS can be found at Training courses Good measurement supports the technical infrastructure, which leads to new and competitive products with efficient processes. However, knowing how to use a measurement tool is not the same as knowing how to use measurement as a tool. Measurement is a science to be applied with skill, not a manual. Understanding the principles of measurement can lead to better decisions on product purchasing, reduced need for expensive technical support and reduced operational mistakes with expensive consequences. A better understanding of measurement will reduce the risks to your business.
64 52 Appendices NPL is able to provide a variety of practical application-based bespoke training courses from optical and laser technology to statistical modelling. The majority of our courses are organised to meet the specific requirements of the customer. To enquire about NPL developing you a bespoke course please contact the NPL Helpline. NPL also has a training framework for Dimensional Metrology. The NPL-Training for Dimensional Metrology is divided into four levels, covering measurement users to measurement strategy definers, always through a practical hands-on approach: Level 1 Measurement User: Uses measurement knowledge and expertise Level 2 Measurement Applier: Applies measurement knowledge and expertise Level 3 Measurement Developer: Develops and extends measurement knowledge and expertise Level 4 Measurement Definer: Defines new and leading edge application of measurement knowledge For further information visit the NPL training at or contact the NPL Helpline: Tel: , Fax: , [email protected] International standards International Organization for Standardization (ISO) The International Organization for Standardization (ISO) is a worldwide federation on national standards bodies from some 140 countries. The mission of ISO is to promote the development of standardisation and related activities in the world with a view to facilitating the international exchange of goods and services, and to develop cooperation in the sphere of intellectual, scientific, technological and economic activity. ISO s work results in international agreements that are published as International Standards. Further information of ISO can be found at
65 53 Appendices ISO surface texture standards The following ISO specification standards relate to the measurement of profile using stylus instruments and are included in this guide for completeness. At the time of publication of this guide the standards for areal surface texture measurements and CSIs are being drafted by ISO TC 213 (see chapter 1 Scope of this guide). ISO 3274 (1996) Geometrical product specifications (GPS) Surface texture: Profile method Nominal characteristics of contact (stylus) instruments ISO 4287 (1997) Geometrical product specifications (GPS) Surface texture: Profile method Terms, definitions and surface texture parameters ISO 4288 (1996) Geometrical product specifications (GPS) Surface texture: Profile method Rules and procedures for the assessment of surface texture ISO 5436 (2000) Geometrical product specifications (GPS) Surface texture: Profile method Measurement standards Part 1 Material measures ISO (1996) Geometrical product specifications (GPS) Surface texture: Profile method Metrological characteristics of phase correct filters ISO (1996) Geometrical product specifications (GPS) Surface texture: Profile method; Surface having stratified functional properties Part 1: Filtering and general measurement conditions ISO (1996) Geometrical product specifications (GPS) Surface texture: Profile method; Surface having stratified functional properties Part 2: Height characterization using the linear material ratio curve ISO (2000) Geometrical product specifications (GPS) Surface texture: Profile method; surfaces having stratified functional properties Part 3: Height characterization using the material probability curve ISO (1996) ISO (1996) Geometrical product specifications (GPS) Surface texture: Profile method Motif parameters General interest PD 6461 (1995) Vocabulary of metrology Part 1. Basic and general terms (international) PD 6461 (1995) Vocabulary of metrology Part 2. Vocabulary of legal metrology fundamental terms PD 6461 (1995) Vocabulary of metrology Part 3. Guide to the expression of uncertainty in measurement
66 54 Appendices Semiconductor Equipment and Materials International (SEMI) SEMI is a volunteer-driven organisation for the exchange of information amongst users and suppliers in the semiconductor industry and flat panel display industries. Approximately 1300 technologists worldwide participate in the development of specifications and standards for these technologies. The documents are published as the SEMI Book of Standards and are available on the web at Literature Surface texture books Bennett J M, Mattson L 1999 An introduction to surface roughness and scattering 2 nd Edition (Optical Society of America: Washington D. C.) Blunt L, Jiang X 2003 Advanced techniques for assessment surface topography (Kogan Page Science) Leach R K 2001 The measurement of surface texture using stylus instruments, NPL Good Practice Guide No. 37 (available from Mainsah E, Greenwood J A, Chewynd D G 2001 Metrology and properties of engineering surfaces (Kluwar Academic Publishers) Smith G T 2001 Industrial metrology: surface and roundness (Springer-Verlag) Stout K J, Blunt L 2000 Three dimensional surface topography (Prenton Press) Thomas T R 1999 Rough surface 2 nd edition (Imperial College Press: London) Whitehouse D J 1994 Handbook of surface metrology (Taylor & Francis) Whitehouse D J 1993 Handbook of surface and nanometrology (CRC Press) General measurement and instrumentation books Flack D R, Hannaford J 2005 Fundamental good practice in dimensional metrology NPL Good Practice Guide No. 80 (available from Smith S T, Chetwynd D G 1992 Foundations of ultraprecision mechanism design (Gordon & Breach Science Publishers) Williams D C 1993 Optical methods in engineering metrology (Chapman & Hall)
67
68
Plastic Film Texture Measurement With 3D Profilometry
Plastic Film Texture Measurement With 3D Profilometry Prepared by Jorge Ramirez 6 Morgan, Ste156, Irvine CA 92618 P: 949.461.9292 F: 949.461.9232 nanovea.com Today's standard for tomorrow's materials.
Perthometer. Surface Texture Parameters New Standards DIN EN ISO / ASME
Perthometer. Surface Texture Parameters New Standards DIN EN ISO / ASME MAHR GMBH, Germany - EDITION 09/01/99 Contents Real surface... Geometrical Product Specification Definition Profile filter P t Profile
Application Note #503 Comparing 3D Optical Microscopy Techniques for Metrology Applications
Screw thread image generated by WLI Steep PSS angles WLI color imaging Application Note #503 Comparing 3D Optical Microscopy Techniques for Metrology Applications 3D optical microscopy is a mainstay metrology
Optical Methods of Surface Measurement
Optical Methods of Surface Measurement Ted Vorburger, Guest Researcher National Institute of Standards and Technology (NIST) Measurement Science and Standards in Forensic Firearms Analysis 2012 NIST, Gaithersburg,
ENGINEERING METROLOGY
ENGINEERING METROLOGY ACADEMIC YEAR 92-93, SEMESTER ONE COORDINATE MEASURING MACHINES OPTICAL MEASUREMENT SYSTEMS; DEPARTMENT OF MECHANICAL ENGINEERING ISFAHAN UNIVERSITY OF TECHNOLOGY Coordinate Measuring
MEASUREMENT OF END FACE GEOMETRY ON FIBER OPTIC TERMINI...2
MEASUREMENT OF END FACE GEOMETRY ON FIBER OPTIC TERMINI...2 IMPORTANCE OF END FACE GEOMETRY...2 FIBER OPTIC CONNECTOR END FACE GEOMETRY MEASUREMENT TECHNIQUES...2 INTERFEROMETRIC MICROSCOPE TYPES...3 MEASUREMENT
AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light
AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light Name: Period: Date: MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question. 1) Reflection,
Calibration of AFM with virtual standards; robust, versatile and accurate. Richard Koops VSL Dutch Metrology Institute Delft
Calibration of AFM with virtual standards; robust, versatile and accurate Richard Koops VSL Dutch Metrology Institute Delft 19-11-2015 VSL Dutch Metrology Institute VSL is the national metrology institute
Interference. Physics 102 Workshop #3. General Instructions
Interference Physics 102 Workshop #3 Name: Lab Partner(s): Instructor: Time of Workshop: General Instructions Workshop exercises are to be carried out in groups of three. One report per group is due by
Application Report: Running µshape TM on a VF-20 Interferometer
: Running µshape TM on a VF-20 Interferometer General This report describes how a fiber interferometer from Arden Photonics Ltd was used together with the µshape TM Generic software package. The VF-20
Optical Metrology. Third Edition. Kjell J. Gasvik Spectra Vision AS, Trondheim, Norway JOHN WILEY & SONS, LTD
2008 AGI-Information Management Consultants May be used for personal purporses only or by libraries associated to dandelon.com network. Optical Metrology Third Edition Kjell J. Gasvik Spectra Vision AS,
Personal Identity Verification (PIV) IMAGE QUALITY SPECIFICATIONS FOR SINGLE FINGER CAPTURE DEVICES
Personal Identity Verification (PIV) IMAGE QUALITY SPECIFICATIONS FOR SINGLE FINGER CAPTURE DEVICES 1.0 SCOPE AND PURPOSE These specifications apply to fingerprint capture devices which scan and capture
FTIR Instrumentation
FTIR Instrumentation Adopted from the FTIR lab instruction by H.-N. Hsieh, New Jersey Institute of Technology: http://www-ec.njit.edu/~hsieh/ene669/ftir.html 1. IR Instrumentation Two types of instrumentation
1051-232 Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002
05-232 Imaging Systems Laboratory II Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002 Abstract: For designing the optics of an imaging system, one of the main types of tools used today is optical
Optical Standards. John Nichol BSc MSc
Optical Standards John Nichol BSc MSc The following notes are presented to explain: Spherical Aberration The Airy Disk Peak to Valley, RMS and Strehl Ratio Standards of Optics produced by Nichol Optical
DETECTION OF SUBSURFACE DAMAGE IN OPTICAL TRANSPARENT MATERIALSS USING SHORT COHERENCE TOMOGRAPHY. Rainer Boerret, Dominik Wiedemann, Andreas Kelm
URN (Paper): urn:nbn:de:gbv:ilm1-2014iwk-199:0 58 th ILMENAU SCIENTIFIC COLLOQUIUM Technische Universität Ilmenau, 08 12 September 2014 URN: urn:nbn:de:gbv:ilm1-2014iwk:3 DETECTION OF SUBSURFACE DAMAGE
Good Practice Guide No. 37. The Measurement of Surface Texture using Stylus Instruments. Richard K Leach. Issue 2
Good Practice Guide No. 37 The Measurement of Surface Texture using Stylus Instruments Richard K Leach Issue 2 Measurement Good Practice Guide No. 37 The Measurement of Surface Texture using Stylus Instruments
A Guide to Acousto-Optic Modulators
A Guide to Acousto-Optic Modulators D. J. McCarron December 7, 2007 1 Introduction Acousto-optic modulators (AOMs) are useful devices which allow the frequency, intensity and direction of a laser beam
Solving Simultaneous Equations and Matrices
Solving Simultaneous Equations and Matrices The following represents a systematic investigation for the steps used to solve two simultaneous linear equations in two unknowns. The motivation for considering
Introduction to Surface Roughness Measurement
Introduction to Surface Roughness Measurement Thank you for reading the Introduction to Surface Roughness Measurement. This document includes the definition of and technical information on the parameters
MANUAL TR-110 TR-110
MANUAL TR-110 TR-110 CONTENTS 1. GENERAL INTRODUCTION 2 2. WORK PRINCIPLE 3 3. STANDARD DELIVERY 4 4. NAME OF EACH PART 5 5. OPERATION 6 5.1 Preparation before operation 6 5.2 Switch on, Switch off and
Lecture 14. Point Spread Function (PSF)
Lecture 14 Point Spread Function (PSF), Modulation Transfer Function (MTF), Signal-to-noise Ratio (SNR), Contrast-to-noise Ratio (CNR), and Receiver Operating Curves (ROC) Point Spread Function (PSF) Recollect
PHYS 39a Lab 3: Microscope Optics
PHYS 39a Lab 3: Microscope Optics Trevor Kafka December 15, 2014 Abstract In this lab task, we sought to use critical illumination and Köhler illumination techniques to view the image of a 1000 lines-per-inch
User checks and maintenance of laboratory balances
Technical Note 13 March 2014 Issued: July 1995 Amended and reissued: July 2005, July 2007, October 2007, May 2010, March 2013, March 2014 User checks and maintenance of laboratory balances Copyright National
3D TOPOGRAPHY & IMAGE OVERLAY OF PRINTED CIRCUIT BOARD ASSEMBLY
3D TOPOGRAPHY & IMAGE OVERLAY OF PRINTED CIRCUIT BOARD ASSEMBLY Prepared by Duanjie Li, PhD & Andrea Novitsky 6 Morgan, Ste156, Irvine CA 92618 P: 949.461.9292 F: 949.461.9232 nanovea.com Today's standard
Measuring Line Edge Roughness: Fluctuations in Uncertainty
Tutor6.doc: Version 5/6/08 T h e L i t h o g r a p h y E x p e r t (August 008) Measuring Line Edge Roughness: Fluctuations in Uncertainty Line edge roughness () is the deviation of a feature edge (as
A comparison of radio direction-finding technologies. Paul Denisowski, Applications Engineer Rohde & Schwarz
A comparison of radio direction-finding technologies Paul Denisowski, Applications Engineer Rohde & Schwarz Topics General introduction to radiolocation Manual DF techniques Doppler DF Time difference
DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS RAYLEIGH-SOMMERFELD DIFFRACTION INTEGRAL OF THE FIRST KIND
DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS RAYLEIGH-SOMMERFELD DIFFRACTION INTEGRAL OF THE FIRST KIND THE THREE-DIMENSIONAL DISTRIBUTION OF THE RADIANT FLUX DENSITY AT THE FOCUS OF A CONVERGENCE BEAM
Non-Contact Vibration Measurement of Micro-Structures
Non-Contact Vibration Measurement of Micro-Structures Using Laser Doppler Vibrometry (LDV) and Planar Motion Analysis (PMA) to examine and assess the vibration characteristics of micro- and macro-structures.
Diffraction of a Circular Aperture
Diffraction of a Circular Aperture Diffraction can be understood by considering the wave nature of light. Huygen's principle, illustrated in the image below, states that each point on a propagating wavefront
Encoders for Linear Motors in the Electronics Industry
Technical Information Encoders for Linear Motors in the Electronics Industry The semiconductor industry and automation technology increasingly require more precise and faster machines in order to satisfy
Metrology of silicon photovoltaic cells using coherence correlation interferometry
Loughborough University Institutional Repository Metrology of silicon photovoltaic cells using coherence correlation interferometry This item was submitted to Loughborough University's Institutional Repository
Holography 1 HOLOGRAPHY
Holography 1 HOLOGRAPHY Introduction and Background The aesthetic appeal and commercial usefulness of holography are both related to the ability of a hologram to store a three-dimensional image. Unlike
Optical modeling of finite element surface displacements using commercial software
Optical modeling of finite element surface displacements using commercial software Keith B. Doyle, Victor L. Genberg, Gregory J. Michels, Gary R. Bisson Sigmadyne, Inc. 803 West Avenue, Rochester, NY 14611
Module 13 : Measurements on Fiber Optic Systems
Module 13 : Measurements on Fiber Optic Systems Lecture : Measurements on Fiber Optic Systems Objectives In this lecture you will learn the following Measurements on Fiber Optic Systems Attenuation (Loss)
Fraunhofer Diffraction
Physics 334 Spring 1 Purpose Fraunhofer Diffraction The experiment will test the theory of Fraunhofer diffraction at a single slit by comparing a careful measurement of the angular dependence of intensity
EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab
EXPERIMENT O-6 Michelson Interferometer Abstract A Michelson interferometer, constructed by the student, is used to measure the wavelength of He-Ne laser light and the index of refraction of a flat transparent
6.4 Normal Distribution
Contents 6.4 Normal Distribution....................... 381 6.4.1 Characteristics of the Normal Distribution....... 381 6.4.2 The Standardized Normal Distribution......... 385 6.4.3 Meaning of Areas under
ING LA PALMA TECHNICAL NOTE No. 130. Investigation of Low Fringing Detectors on the ISIS Spectrograph.
ING LA PALMA TECHNICAL NOTE No. 130 Investigation of Low Fringing Detectors on the ISIS Spectrograph. Simon Tulloch (ING) June 2005 Investigation of Low Fringing Detectors on the ISIS Spectrograph. 1.
Sound Power Measurement
Sound Power Measurement A sound source will radiate different sound powers in different environments, especially at low frequencies when the wavelength is comparable to the size of the room 1. Fortunately
DESCRIPTIVE STATISTICS. The purpose of statistics is to condense raw data to make it easier to answer specific questions; test hypotheses.
DESCRIPTIVE STATISTICS The purpose of statistics is to condense raw data to make it easier to answer specific questions; test hypotheses. DESCRIPTIVE VS. INFERENTIAL STATISTICS Descriptive To organize,
Introduction to Fourier Transform Infrared Spectrometry
Introduction to Fourier Transform Infrared Spectrometry What is FT-IR? I N T R O D U C T I O N FT-IR stands for Fourier Transform InfraRed, the preferred method of infrared spectroscopy. In infrared spectroscopy,
Introduction to Add-Drop Multiplexers
3 Introduction to Add-Drop Multiplexers In this chapter different channel routing technologies are reviewed, highlighting the advantages and drawbacks of the different devices and configurations. The parameters
Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications
Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications Saulius Marcinkevičius Optics, ICT, KTH 1 Outline Optical near field. Principle of scanning near field optical microscope
Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ.
Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ., Raleigh, NC One vital step is to choose a transfer lens matched to your
TABLET ROUGHNESS INSPECTION WITH 3D PROFILOMETRY
TABLET ROUGHNESS INSPECTION WITH 3D PROFILOMETRY Prepared by Benjamin Mell 6 Morgan, Ste156, Irvine CA 92618 P: 949.461.9292 F: 949.461.9232 nanovea.com Today's standard for tomorrow's materials. 2011
Characterizing Digital Cameras with the Photon Transfer Curve
Characterizing Digital Cameras with the Photon Transfer Curve By: David Gardner Summit Imaging (All rights reserved) Introduction Purchasing a camera for high performance imaging applications is frequently
Section 5.0 : Horn Physics. By Martin J. King, 6/29/08 Copyright 2008 by Martin J. King. All Rights Reserved.
Section 5. : Horn Physics Section 5. : Horn Physics By Martin J. King, 6/29/8 Copyright 28 by Martin J. King. All Rights Reserved. Before discussing the design of a horn loaded loudspeaker system, it is
Fundamentals of modern UV-visible spectroscopy. Presentation Materials
Fundamentals of modern UV-visible spectroscopy Presentation Materials The Electromagnetic Spectrum E = hν ν = c / λ 1 Electronic Transitions in Formaldehyde 2 Electronic Transitions and Spectra of Atoms
X-ray thin-film measurement techniques
Technical articles X-ray thin-film measurement techniques II. Out-of-plane diffraction measurements Toru Mitsunaga* 1. Introduction A thin-film sample is two-dimensionally formed on the surface of a substrate,
CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL
CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL Robert Bagnell 2006 This tutorial covers the following CLSM topics: 1) What is the optical principal behind CLSM? 2) What is the spatial resolution in X, Y,
Understanding astigmatism Spring 2003
MAS450/854 Understanding astigmatism Spring 2003 March 9th 2003 Introduction Spherical lens with no astigmatism Crossed cylindrical lenses with astigmatism Horizontal focus Vertical focus Plane of sharpest
Geometric Optics Converging Lenses and Mirrors Physics Lab IV
Objective Geometric Optics Converging Lenses and Mirrors Physics Lab IV In this set of lab exercises, the basic properties geometric optics concerning converging lenses and mirrors will be explored. The
Fibre Bragg Grating Sensors An Introduction to Bragg gratings and interrogation techniques
Fibre Bragg Grating Sensors An ntroduction to Bragg gratings and interrogation techniques Dr Crispin Doyle Senior Applications Engineer, Smart Fibres Ltd. 2003 1) The Fibre Bragg Grating (FBG) There are
Resolution for Color photography
Resolution for Color photography Paul M. Hubel a and Markus Bautsch b a Foveon, Inc., 282 San Tomas Expressway, Santa Clara, CA, USA 955; b Stiftung Warentest, Luetzowplatz -3, D-785 Berlin-Tiergarten,
Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff
Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff December 2012 Specifying Advanced Plasma Deposited Hard Coated Optical Bandpass and Dichroic Filters. Introduction
Scanners and How to Use Them
Written by Jonathan Sachs Copyright 1996-1999 Digital Light & Color Introduction A scanner is a device that converts images to a digital file you can use with your computer. There are many different types
2. Simple Linear Regression
Research methods - II 3 2. Simple Linear Regression Simple linear regression is a technique in parametric statistics that is commonly used for analyzing mean response of a variable Y which changes according
Physics 441/2: Transmission Electron Microscope
Physics 441/2: Transmission Electron Microscope Introduction In this experiment we will explore the use of transmission electron microscopy (TEM) to take us into the world of ultrasmall structures. This
digital quality control fail pass at your fingertips Smart Metrology Solutions.
digital quality control fail pass µphase smartgage The clever innovation in digital metrology by FISBA, which lets you smarten up your quality management and economize your production processes, yet spares
E190Q Lecture 5 Autonomous Robot Navigation
E190Q Lecture 5 Autonomous Robot Navigation Instructor: Chris Clark Semester: Spring 2014 1 Figures courtesy of Siegwart & Nourbakhsh Control Structures Planning Based Control Prior Knowledge Operator
Introduction to Optics
Second Edition Introduction to Optics FRANK L. PEDROTTI, S.J. Marquette University Milwaukee, Wisconsin Vatican Radio, Rome LENO S. PEDROTTI Center for Occupational Research and Development Waco, Texas
Reflection and Refraction
Equipment Reflection and Refraction Acrylic block set, plane-concave-convex universal mirror, cork board, cork board stand, pins, flashlight, protractor, ruler, mirror worksheet, rectangular block worksheet,
LIST OF CONTENTS CHAPTER CONTENT PAGE DECLARATION DEDICATION ACKNOWLEDGEMENTS ABSTRACT ABSTRAK
vii LIST OF CONTENTS CHAPTER CONTENT PAGE DECLARATION DEDICATION ACKNOWLEDGEMENTS ABSTRACT ABSTRAK LIST OF CONTENTS LIST OF TABLES LIST OF FIGURES LIST OF NOTATIONS LIST OF ABBREVIATIONS LIST OF APPENDICES
Measuring large areas by white light interferometry at the nanopositioning and nanomeasuring machine (NPMM)
Image Processing, Image Analysis and Computer Vision Measuring large areas by white light interferometry at the nanopositioning and nanomeasuring machine (NPMM) Authors: Daniel Kapusi 1 Torsten Machleidt
Length, Finland, MIKES (VTT Technical Research Centre of Finland Ltd, Centre for Metrology / Mittatekniikan keskus)
absolute mise en pratigue: mise en pratigue: absolute absolute Level or Range 633 633 nm 0.04 fm 2 95% No 1 474 474 THz 24 khz 2 95% No 1 532 532 nm 0.08 fm 2 95% No 50 563 563 THz 0.08 MHz 2 95% No 51
LARGE MEASUREMENT RANGE MECHANICAL COMPARATOR FOR CALIBRATION OF LONG GAUGE BLOCKS
XVII IMEKO World Congress Metrology in the 3rd Millennium June 22 27, 2003, Dubrovnik, Croatia LARGE MEASUREMENT RANGE MECHANICAL COMPARATOR FOR CALIBRATION OF LONG GAUGE BLOCKS Tanfer Yandayan TUBITAK-Ulusal
First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between
Optical Differences Between Telescopes and Microscopes Robert R. Pavlis, Girard, Kansas USA icroscopes and telescopes are optical instruments that are designed to permit observation of objects and details
Fiber Optics: Fiber Basics
Photonics Technical Note # 21 Fiber Optics Fiber Optics: Fiber Basics Optical fibers are circular dielectric wave-guides that can transport optical energy and information. They have a central core surrounded
To measure an object length, note the number of divisions spanned by the object then multiply by the conversion factor for the magnification used.
STAGE MICROMETERS Introduction Whenever there is a need to make measurements with an eyepiece graticule, there is also a need to ensure that the microscope is calibrated. The use of a stage micrometer
OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT
OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT PA/PH/OMCL (12) 77 7R QUALIFICATION OF EQUIPMENT ANNEX 8: QUALIFICATION OF BALANCES Full document title and reference Document type Qualification
Reflectance Measurements of Materials Used in the Solar Industry. Selecting the Appropriate Accessories for UV/Vis/NIR Measurements.
T e c h n i c a l N o t e Reflectance Measurements of Materials Used in the Solar Industry UV/Vis/NIR Author: Dr. Jeffrey L. Taylor PerkinElmer, Inc. 710 Bridgeport Avenue Shelton, CT 06484 USA Selecting
Efficiency, Dispersion and Straylight Performance Tests of Immersed Gratings for High Resolution Spectroscopy in the Near Infra-red
Changing the economics of space Efficiency, Dispersion and Straylight Performance Tests of Immersed Gratings for High Resolution Spectroscopy in the Near Infra-red J. Fernandez-Saldivar 1, F. Culfaz 1,
Current Standard: Mathematical Concepts and Applications Shape, Space, and Measurement- Primary
Shape, Space, and Measurement- Primary A student shall apply concepts of shape, space, and measurement to solve problems involving two- and three-dimensional shapes by demonstrating an understanding of:
Experiment 3 Lenses and Images
Experiment 3 Lenses and Images Who shall teach thee, unless it be thine own eyes? Euripides (480?-406? BC) OBJECTIVES To examine the nature and location of images formed by es. THEORY Lenses are frequently
Big Ideas in Mathematics
Big Ideas in Mathematics which are important to all mathematics learning. (Adapted from the NCTM Curriculum Focal Points, 2006) The Mathematics Big Ideas are organized using the PA Mathematics Standards
Today. next two weeks
Today Temporal and spatial coherence Spatially incoherent imaging The incoherent PSF The Optical Transfer Function (OTF) and Modulation Transfer Function (MTF) MTF and contrast comparison of spatially
GRID AND PRISM SPECTROMETERS
FYSA230/2 GRID AND PRISM SPECTROMETERS 1. Introduction Electromagnetic radiation (e.g. visible light) experiences reflection, refraction, interference and diffraction phenomena when entering and passing
Chapter 10. Key Ideas Correlation, Correlation Coefficient (r),
Chapter 0 Key Ideas Correlation, Correlation Coefficient (r), Section 0-: Overview We have already explored the basics of describing single variable data sets. However, when two quantitative variables
Automatic and Objective Measurement of Residual Stress and Cord in Glass
Automatic and Objective Measurement of Residual Stress and Cord in Glass GlassTrend - ICG TC15/21 Seminar SENSORS AND PROCESS CONTROL 13-14 October 2015, Eindhoven Henning Katte, ilis gmbh copyright ilis
CALCULATIONS & STATISTICS
CALCULATIONS & STATISTICS CALCULATION OF SCORES Conversion of 1-5 scale to 0-100 scores When you look at your report, you will notice that the scores are reported on a 0-100 scale, even though respondents
Some additional standards and specifications that directly or indirectly affect surface finish requirements include:
Surface Finish Charts Surface Finish Affects Performance The surface finish of process vessels, piping and related components can be a critical factor in their performance, maintenance costs, and service
Encoded Phased Array Bridge Pin Inspection
Encoded Phased Array Bridge Pin Inspection James S. Doyle Baker Testing Services, Inc. 22 Reservoir Park Dr. Rockland, MA 02370 (781) 871-4458; fax (781) 871-0123; e-mail [email protected] Product
Grazing incidence wavefront sensing and verification of X-ray optics performance
Grazing incidence wavefront sensing and verification of X-ray optics performance Timo T. Saha, Scott Rohrbach, and William W. Zhang, NASA Goddard Space Flight Center, Greenbelt, Md 20771 Evaluation of
Data Exploration Data Visualization
Data Exploration Data Visualization What is data exploration? A preliminary exploration of the data to better understand its characteristics. Key motivations of data exploration include Helping to select
Active Vibration Isolation of an Unbalanced Machine Spindle
UCRL-CONF-206108 Active Vibration Isolation of an Unbalanced Machine Spindle D. J. Hopkins, P. Geraghty August 18, 2004 American Society of Precision Engineering Annual Conference Orlando, FL, United States
Evaluating System Suitability CE, GC, LC and A/D ChemStation Revisions: A.03.0x- A.08.0x
CE, GC, LC and A/D ChemStation Revisions: A.03.0x- A.08.0x This document is believed to be accurate and up-to-date. However, Agilent Technologies, Inc. cannot assume responsibility for the use of this
A technical overview of the Fuel3D system.
A technical overview of the Fuel3D system. Contents Introduction 3 How does Fuel3D actually work? 4 Photometric imaging for high-resolution surface detail 4 Optical localization to track movement during
A NEW LOOK AT RISLEY PRISMS. By Craig Schwarze Senior Systems Engineer OPTRA Inc.
As seen in Photonics Spectra June 2006: A NEW LOOK AT RISLEY PRISMS By Craig Schwarze Senior Systems Engineer OPTRA Inc. Introduction With laser beams finding more and more applications that require aiming
Signal to Noise Instrumental Excel Assignment
Signal to Noise Instrumental Excel Assignment Instrumental methods, as all techniques involved in physical measurements, are limited by both the precision and accuracy. The precision and accuracy of a
3.5.4.2 One example: Michelson interferometer
3.5.4.2 One example: Michelson interferometer mirror 1 mirror 2 light source 1 2 3 beam splitter 4 object (n object ) interference pattern we either observe fringes of same thickness (parallel light) or
WOOD WEAR TESTING USING TRIBOMETER
WOOD WEAR TESTING USING TRIBOMETER Prepared by Duanjie Li, PhD 6 Morgan, Ste156, Irvine CA 92618 P: 949.461.9292 F: 949.461.9232 nanovea.com Today's standard for tomorrow's materials. 2015 NANOVEA INTRO
WHITE PAPER. Methods for Measuring Flat Panel Display Defects and Mura as Correlated to Human Visual Perception
Methods for Measuring Flat Panel Display Defects and Mura as Correlated to Human Visual Perception Methods for Measuring Flat Panel Display Defects and Mura as Correlated to Human Visual Perception Abstract
Video Camera Image Quality in Physical Electronic Security Systems
Video Camera Image Quality in Physical Electronic Security Systems Video Camera Image Quality in Physical Electronic Security Systems In the second decade of the 21st century, annual revenue for the global
Whitepaper. Image stabilization improving camera usability
Whitepaper Image stabilization improving camera usability Table of contents 1. Introduction 3 2. Vibration Impact on Video Output 3 3. Image Stabilization Techniques 3 3.1 Optical Image Stabilization 3
Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications
Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications Janet E. Semmens Sonoscan, Inc. 2149 E. Pratt Boulevard Elk Grove Village, IL 60007 USA Phone: (847)
Trigonometric functions and sound
Trigonometric functions and sound The sounds we hear are caused by vibrations that send pressure waves through the air. Our ears respond to these pressure waves and signal the brain about their amplitude
4. CAMERA ADJUSTMENTS
4. CAMERA ADJUSTMENTS Only by the possibility of displacing lens and rear standard all advantages of a view camera are fully utilized. These displacements serve for control of perspective, positioning
Comparing Digital and Analogue X-ray Inspection for BGA, Flip Chip and CSP Analysis
Comparing Digital and Analogue X-ray Inspection for BGA, Flip Chip and CSP Analysis David Bernard & Steve Ainsworth Dage Precision Industries Abstract Non-destructive testing during the manufacture of
