NON RETURN & FLAP VALVES

Size: px
Start display at page:

Download "NON RETURN & FLAP VALVES"

Transcription

1 RUR UK NON RTURN & P VVS RUR UK The Original and est - Rubber lexible ouplings and ushes

2 INTROUTION P VVS The principle applications for flap valves are for surface water drainage associated with river, estuary and sea water outfalls to prevent backflow into the sewer and for final effluent outfalls from wastewater treatment works to prevent flood damage within the works. NON-RTURN VVS Non return valves or backwater valves are used within sewerage and drainage systems to eliminate the risk of flood damage by the backflow of sewage or flood water into properties through low level entries such as low level drain gullies, toilets and washing machine outlets. The nvironment gency in their publication on damage limitation for properties at risk from flooding and the Government guidance note Preparing for loods both recommend the installation of non-return valves (anti-flooding devices) on all such drains and sewers. The uilding Regulations 2000, pproved ocument, recommends the installation of non-return valves on drains from basements in low risk areas and on all drains in areas with a high risk of flooding or sewer surcharge. These valves are also used in commercial and industrial application where non-pressure flow control is required (e.g. fish farming) MTRIS P VVS ody & flap - Glass reinforced plastic using a isophtalic polyester resin with surface isophtalic gel coat inge - Self lubricating rtacetal plastic Seal - thylene Propylene iene Monomer (PM) to S N 1-1 Optional nitrile (NR) seal available ittings - Grade 1.01 (31) austenitic stainless Steel to S N NON-RTURN VVS RI (N100 to 00) ody & lap - PVu Seal - thylene Propylene iene Monomer (PM) to S N 1-1 Norham (N to ) ody & flap - Glass reinforced plastic using a isophtalic polyester resin with surface isophtalic gel coat inge - Self lubricating rtacetal plastic Seal - thylene Propylene iene Monomer (PM) to S N 1-1 Optional nitrile (NR) seal available ittings - Grade 1.01 (31) austenitic stainless steel to S N RUR UK The Original and est - Rubber lexible ouplings and ushes

3 NON RTURN VVS RI N100 to N00 range of PVu non return valves complying with the requirements of S N nti-flooding devices for buildings. Sizes N100 to N200 are certified by the German Institute G. These valves are watertight to a pressure of 0.5 bar (5m ead). These valves have a spigot and socket with integral seal as standard for direct connection to solid walled PVu pipe but double spigot versions are available to special order for sizes N00 and above. They can be connected to other pipe material using Mission Rubber lexible couplings (see separate technical brochure). N N - N00-00 Single lap with ocking ever N Nominal Size N RRN N100R N150 N150R N200 N N200 N Single lap without ocking ever 1 2 Nominal Size 1 2 RRN N00 N T N-00 N00 30 R = Stainless Steel lap = Outside iameter Spigot T RUR UK The Original and est - - Rubber lexible ouplings and and ushes 3

4 NON RTURN VVS Norham N to N range of grp non-return valves designed for connection to any pipe material using Mission Rubber Standard ouplings and ushes. VNTGS Resistant to 1bar (10m head) back pressure ow weight for ease of installation yet with high mechanical strength Resistant to all normal sewage effluents operating at normal temperatures (below 0 ) and not containing harmful industrial effluents. Seals at a low level of back pressure asily connected to any type of pipe material ow maintenance N N - N Wgt(kg) MUTI MUTI MUTI MUTI RUR UK The Original and est - Rubber lexible ouplings and ushes

5 P VVS range of grp flap valves designed for ease of installation due to their low weight but with exceptional mechanical strength and durability. VNTGS Resistant to 1bar (10m head) back pressure (Multi- 0. bar) Most sizes can be handled by one person due to low weight ow weight ensures ease of installation igh mechanical strength igh resistance to corrosion and ultraviolet degradation Seals at a low level of back pressure ow operating head due to low weight ow maintenance MUTI N N200 to 00 range of flap valves designed for direct connection to any type of drain or sewer pipe using Mission Rubber Standard ouplings and ushes VNTGS liminates need for concrete headwall or pipe flange for fixing e.g. can be connected to the spigot of an outfall pipe passing through gabions No drilling required ast and easy installation Wgt(kg) MUTI200N MUTIN MUTIN MUTI00N MUTIN MUTI00N Ø RUR UK The Original and est - Rubber lexible ouplings and ushes 5

6 P VVS MUTI N100 to N200 range of small diameter flap valves with a PN 10 flange and an integral foamed PM rubber gasket for direct fixing to a flange or concrete headwall. VNTGS Wgt(kg) ightweight for fast and easy installation No need for cement grout when fixing to a headwall MUTI100 MUTI125 MUTI MUTI Wall mounting kits available Ø MUTI N to 00 range of medium diameter flap valves with a PN 10 flange. Integral PM rubber sealing rings for sealing to concrete headwall. VNTGS ightweight for fast and easy installation. Resistant to 0.bar (m head) backpressure. No need for cement grout when fixing to headwall. inged design ensures full face sealing when closed. N Wgt.(kg) MUTI MUTI MUTI MUTI MUTI Wall mounting kits available RUR UK The Original and est - Rubber lexible ouplings and ushes

7 P VVS MUTI N N200 to 1 range of medium diameter flap valves with an inclined flap and PN 10 flange. Integral PM rubber sealing rings for sealing to concrete headwall. N VNTGS ightweight for fast and easy installation. Inclined flap for additional security against backflow. No need for cement grout when fixing to headwall. inged design ensures flap closure when no discharge. Ø N Wgt.(kg) MUTI200N MUTIN N700,00,0-1 MUTIN MUTI00N MUTIN Ø MUTI00N MUTI700N MUTI00N MUTI1000N MUTI0N MUTI100N N1000 MUTI1N Wall mounting kits available 25 RUR UK The Original and est - Rubber lexible ouplings and ushes 7

8 TNI T NORM P VV TNI T P OS mm Number iameter (mm) MUTI Ø1 MUTI Ø1 MUTI Ø22 MUTI Ø22 MUTI 350 MUTI 00 MUTI MUTI 20 MUTI MUTI200N 295 MUTIN 350 MUTIN 00 MUTI00N 515 MUTIN 20 MUTI00N 725 MUTI700N 20 MUTI00N 915 MUTI1000N 110 Ø21 MUTI0N 1320 Ø15 MUTI100N Ø15 MUTI1N Ø15 NOT: P = PIT IR IMTR O T OT OS langes drilled to S N 1092 PN10 pitch circle diameter as standard except those marked in red. Standard bolt holes in the flanges are not drilled to S N 1092 diameters (see table) but can be supplied to special order. GNR OTIONS lap valves should be fixed so as to avoid the accumulation of debris around the invert which could prevent the valve operating correctly. TI OTIONS Turbulaence of flow due to severe wave action will shorten the working life of a flap valve. Therefore it is recommended that careful consideration is given to the positioning of valves and they are installed within an outfall bay or otherwise protected from direct wave action by baffles. or more information please contact us Tel: +(0) ax: +(0) mail: [email protected] Mission Rubber (UK) imited, Units +5, tlas usiness Park, Starnhill lose, cclesfield, Sheffield, S35 9TG

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION THOMAS - G-FLEX GFLEX TECH SPEC CONNECTING INNOVATION JOHANNESBURG TEL: +27 11 794 7594 CAPE TOWN TEL: +27 21 556 5258 POLOKWANE TEL: 015 298 9142 DESIGNER, MANUFACTURER AND DISTRIBUTOR OF PIPE CONNECTION,

More information

Proposed Construction of Basement Flood Risk Assessment. 35 Edwardes Square London W8 6HH

Proposed Construction of Basement Flood Risk Assessment. 35 Edwardes Square London W8 6HH Proposed Construction of Basement Flood Risk Assessment 35 Edwardes Square London W8 6HH 1 Introduction This FRA has been carried out in accordance with the National Planning Policy Statement (NPPF), the

More information

Greater Dublin Strategic Drainage Study Regional Drainage Policies - Volume 2 New Development

Greater Dublin Strategic Drainage Study Regional Drainage Policies - Volume 2 New Development 7 SPECIFICATIONS There is currently no Irish specification for construction of drainage works, or water supply works. There are several publications that give guidance on drainage works, such as the Building

More information

Does Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5

Does Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5 PROTECTIVE PLUMBING - WHAT IS IT? TABLE OF CONTENTS Protective Plumbing What is it?...page 1 What is Foundation Drainage?...Page 2 What is a Sump Pumping System?...Page 4 Does Part of My Basement Floor

More information

SECTION 02630 STORM DRAINAGE SYSTEM

SECTION 02630 STORM DRAINAGE SYSTEM SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE

More information

Module 3 : Sewer Material. Lecture 3 : Sewer Material

Module 3 : Sewer Material. Lecture 3 : Sewer Material 1 P age Module 3 : Sewer Material Lecture 3 : Sewer Material 2 P age 3.1 Important Factors Considered for Selecting Material for Sewer Following factors should be considered before selecting material for

More information

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

Shower and Floor Gullies Channel Drain and Tile Drain SECTION Shower and Floor Gullies Channel Drain and Tile Drain SECTION 2 Shower and Floor Gullies, Channel Drain and Tile Drain 29 General Information Shower and Floor Gullies McAlpine has responded to market conditions

More information

Wastewater Capital Projects Management Standard Construction Specification

Wastewater Capital Projects Management Standard Construction Specification CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 Precast Concrete Pipe 10.1.1 General This section covers material requirements,

More information

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials

More information

San Antonio Water System Standard Specifications for Construction ITEM NO. 1100 SLIP-LINING SANITARY SEWERS

San Antonio Water System Standard Specifications for Construction ITEM NO. 1100 SLIP-LINING SANITARY SEWERS ITEM NO. 1100 SLIP-LINING SANITARY SEWERS 1100.1 DESCRIPTION: This item shall consist of slip-lining sanitary sewer pipe, which is accomplished by pulling or pushing liner pipe into existing sewers by

More information

Fittings and valves. Ductile cast iron valves. for water and gas supply

Fittings and valves. Ductile cast iron valves. for water and gas supply Fittings and valves Ductile cast iron valves for water and gas supply 1 Valves made of ductile cast iron Reliable, saf The basis cast iron Düker places emphasis on protection: Quality and a long life cycle,

More information

Jay R. Smith Mfg. Co.

Jay R. Smith Mfg. Co. Jay R. Smith Mfg. Co. Automatic Backwater Valve SMITH CUSTOMER DRIVEN FLOOD-GATE FEATURES Index Page Flood-Gate Features and Applications 2 How Flood-Gate Works 3 Flood-Gate Operation & Approvals 4 Valve

More information

Couplings. Drain Couplings Standard Couplings Large Diameter Couplings Adaptor Couplings Flexible Saddles Bushes

Couplings. Drain Couplings Standard Couplings Large Diameter Couplings Adaptor Couplings Flexible Saddles Bushes Drain Couplings Standard Couplings Large Diameter Couplings Adaptor Couplings Flexible Saddles Bushes Flex-Seal couplings meet a range of UK and international legislation requirements and quality standards

More information

SECTION 08000 STORM DRAINAGE TABLE OF CONTENTS

SECTION 08000 STORM DRAINAGE TABLE OF CONTENTS SECTION 08000 STORM DRAINAGE 08010 DESIGN A. Location B. Sizing TABLE OF CONTENTS 08020 MATERIALS A. Pipe Materials B. Structure Materials C. Installation D. Inlets and Outlets 08030 INSPECTIONS AND TESTING

More information

Section 02702 SEWER PIPE INSTALLATION AND TESTING

Section 02702 SEWER PIPE INSTALLATION AND TESTING PART 1 - GENERAL Section 02702 SEWER PIPE INSTALLATION AND TESTING 1-1. SCOPE. This section covers the installation and testing of all sewer pipe furnished under the following specification sections: Concrete

More information

Fabricated Drainage Products

Fabricated Drainage Products Fabricated Drainage Products Complete Drainage System Inline Drains are used At the beginning of a drain line Add a new water inlet to an existing drain line using a riser pipe and tee HARCO Surface Drainage

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

NEW CONNECTION INDUSTRIAL PRODUCTS NC.10V NC.20V NC.30V. NC. SD.10 NC. SD.20 NC. F.Clamp

NEW CONNECTION INDUSTRIAL PRODUCTS NC.10V NC.20V NC.30V. NC. SD.10 NC. SD.20 NC. F.Clamp Repair and Construction. Complete stainless steel pipe repair clamps to repair cracks, fractures, pin holes, torn sockets or welded tees, broken asbest-cement pipe coupling and more. Available for all

More information

Module 3: Sewer Material Lecture 3: Sewer Material

Module 3: Sewer Material Lecture 3: Sewer Material Module 3: Sewer Material Lecture 3: Sewer Material [NPTEL, IIT Kharagpur, Prof. M.M.Ghangrekar, Department of Civil Engineering Page 1 3.0 SEWER MATERIAL 3.1 Important Factors Considered for Selecting

More information

How To Build A Backwater Valve

How To Build A Backwater Valve Photos by: Bobby Thompson, Jeff Napier Illustrations: Rudy Martinez Bobby Thompson July 16, 2009 Presented by Jeff Napier A Backwater Valve is a one way valve that is installed on a building sewer to prevent

More information

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES AIR RELEASE, CLEANOUT, AND SEWER MANHOLES **From Hartford IM BLDG(10) DESCRIPTION. This work shall consist of the construction of air release, cleanout, and sanitary sewer manholes; and the furnishing

More information

DIVISION 4300 STORM DRAINAGE

DIVISION 4300 STORM DRAINAGE DIVISION 4300 STORM DRAINAGE SECTION 4305 STORM SEWER PART 1 - GENERAL 1.01 SCOPE This section covers the construction of storm sewers for the collection and transport of stormwater runoff. 1.02 REFERENCES

More information

Saferand easierinstallation

Saferand easierinstallation EN 85-07 Saferand easierinstallation IföSigninstallationsystem andifösignbuilt-incistern www.ifosanitar.com/sign Aneffectivesolution withmanyadvantages. Ifö Sign installation system makes life a little

More information

CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD NORTH RIDGEVILLE, OH 44039 (440) 353-0819 WWW.NRIDGEVILLE.ORG

CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD NORTH RIDGEVILLE, OH 44039 (440) 353-0819 WWW.NRIDGEVILLE.ORG CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD NORTH RIDGEVILLE, OH 44039 (440) 353-0819 WWW.NRIDGEVILLE.ORG WHY IS THERE WATER IN MY BASEMENT? There are two major sources of water in a basement as the

More information

INTERCEPTORS TABLE OF CONTENTS S-WD-INTER-1 0812

INTERCEPTORS TABLE OF CONTENTS S-WD-INTER-1 0812 TABLE OF CONTENTS Pictorial Index Product Recommendations Grease Interceptors Commonly Specified Options Typical Installations Oil Interceptors Commonly Specified Options Typical Installations Sediment

More information

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

WATER & SEWER CORROSIVE RESISTANT PRODUCTS WATER & SEWER CORROSIVE RESISTANT PRODUCTS The Standard of Excellence in the Industry CASING SPACERS COUPLINGS & FLANGE COUPLING ADAPTERS REPAIR CLAMPS DUCTILE IRON SADDLES STAINLESS STEEL SADDLES TAPPING

More information

Appendix A: Acceptable pipe and fitting materials

Appendix A: Acceptable pipe and fitting materials Watercare Services Limited Water and Code of Practice Content from the NZS 4404:2010 Land development and subdivision infrastructure has been reproduced for use in the Infrastructure Design s Manual for

More information

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter Ed.15.01 Design Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter Standard 4026/60H Pressure rate PN 40

More information

SMITH MFG. CO. PROTECT YOUR INVESTMENTS. Automatic Backwater Valve SMITH MORRIS GROUP INTERNATIONAL. www.morrisgroup.co

SMITH MFG. CO. PROTECT YOUR INVESTMENTS. Automatic Backwater Valve SMITH MORRIS GROUP INTERNATIONAL. www.morrisgroup.co SMITH R SMITH MFG. CO. R MEMBER OF MORRIS GROUP INTERNATIONAL CUSTOMER DRIVEN SINCE 1926 MORRIS GROUP INTERNATIONAL www.morrisgroup.co Index Page FLOOD-GATE FEATURES Flood-Gate Features and Applications

More information

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel

More information

Plugging Home Drains to Prevent Sewage Backup

Plugging Home Drains to Prevent Sewage Backup AE-1476 Plugging Home Drains to Prevent Sewage Backup Why plug drains For homes in areas of the country prone to flooding or heavy rain, taking a few steps to prepare for water levels that could result

More information

VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)

VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01) VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,

More information

SECTION 02700 SEWERAGE AND DRAINAGE PART 1 - GENERAL 1.01 RELATED DOCUMENTS

SECTION 02700 SEWERAGE AND DRAINAGE PART 1 - GENERAL 1.01 RELATED DOCUMENTS SECTION 02700 SEWERAGE AND DRAINAGE PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including the General and Supplementary Conditions and Division 1 Specification

More information

Reticulation sewers in basements Technical guidelines

Reticulation sewers in basements Technical guidelines Reticulation sewers in basements Technical guidelines Overview What These guidelines explain our technical requirements for laying sewers in building basements. The scope of the guide is restricted to

More information

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+ Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+ The wall sleeve The wall sleeve a largely unnoticed but very important sealing part. Wall sleeves

More information

The Town of Lakeshore Basement Flooding Information to Residents

The Town of Lakeshore Basement Flooding Information to Residents The Town of Lakeshore Basement Flooding Information to Residents The following information is intended for residents that have homes connected to Municipal storm and sanitary sewers. However, rural residents

More information

BROEN UNiFlEx FiTTiNgs FOR BURNiNg gases OEN OEN ifl ifl FOR FOR BURN BURN gas gas

BROEN UNiFlEx FiTTiNgs FOR BURNiNg gases OEN OEN ifl ifl FOR FOR BURN BURN gas gas BROEN UNIFLEX Fittings FOR BURNIN ASES BROEN UniFlex TM Fittings for burning gases BROEN UniFlex TM Fittings for burning gases LAB Table of Contents Content Page Table of Content 2 Product Overview 3 BROEN

More information

Access chambers and maintenance shafts. Issue 1

Access chambers and maintenance shafts. Issue 1 Access chambers and maintenance shafts Issue 1 Contents Access chambers (worker-entry) 1 Applications 2 Benefits 2 Design information 3 Components 3 Precast base 3 Shaft 3 Taper top (option one) 3 Squat

More information

Royal Seal Gasketed Sewer Pipe

Royal Seal Gasketed Sewer Pipe Royal Seal Gasketed Sewer Pipe Royal Seal Gasketed Sewer Pipe Royal Seal gasketed sewer pipe with our specially designed Double Seal Locked-In (DSLI ) gasket is an extremely durable pipe with a leak proof

More information

Flowtite Jacking Pipe

Flowtite Jacking Pipe U.S. COMPOSITE PIPE SOUTH, LLC. MEMBER OF KTI PIPE GROUP OF COMPANIES Flowtite Jacking Pipe 18585 Samuels Rd. Zachary, La. 70791 PH. 225-658-6166 Fax 225-658-0947 www.flowtitepipe.com Flowtite GRP Pipe

More information

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION 1. SCOPE Pipe subsoil drains shall be constructed in accordance with this specification and in conformity with the lines, grades and cross-sections shown

More information

GPD Rubber Press Seals

GPD Rubber Press Seals GPD Rubber Press Seals Leading in in ideas SYSTEM-TECHNIK GPD Rubber Press Seals Design Available with a rubber thickness of 30 mm for sealing against non-pressing water and a rubber thickness of 60 mm

More information

SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER

SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER Village of Shorewood, Wisconsin SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER Prepared By: Thomas A. Zoulek, P.E., LEED A.P. Vice President Mid City Plumbing & Heating

More information

British Standard Underground Hydrant Range

British Standard Underground Hydrant Range British Standard Underground Hydrant Range 2 THE NEW AVK BRITISH STANDARD HYDRANT RANGE AVK are the renowned market leading innovators, manufacturers and suppliers of BS 750 fire hydrants into the UK,

More information

CCU Engineering Specifications. Section 003300 PRECAST CONCRETE PRODUCTS

CCU Engineering Specifications. Section 003300 PRECAST CONCRETE PRODUCTS CCU Engineering Specifications Section 003300 Effective Date: Nov. 1st, 2011 Page 1 of 5 PRECAST CONCRETE PRODUCTS PART 1 - GENERAL The following specification is intended for use for the design, selection

More information

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project: PLATE HEAT EXCHANGER Installation Manual Customer Name: Serial number: Purchase order number: Project: Table of Contents ----------------------------------------------------------------- Page: 2 3 Name

More information

GRP Pipe systems. for Water, Sewage and Industrial Applications

GRP Pipe systems. for Water, Sewage and Industrial Applications GRP Pipe systems for Water, Sewage and Industrial Applications AMIANTIT Group of Companies The AMIANTIT Group is an internationally operating organization with a track record of growth-oriented success.

More information

Sewer network renovation using glass-fiber reinforced (GRP) pipe liners

Sewer network renovation using glass-fiber reinforced (GRP) pipe liners Sewer network renovation using glass-fiber reinforced (GRP) pipe liners The BONEX method 1./ Antecedents Several hundred or thousand kilometers is the total length of the communal and industrial sewer

More information

Concrete Pipes. Concrete Pipes

Concrete Pipes. Concrete Pipes Various Types of Manufactured and Supplied by the Wolfman Company 1. Data Concrete pipes of all types are manufactured at Wolfman according to IS-27 (May 2010). IS 27 is the Israeli Standard that adopted

More information

valid as of 1 April 2014 Intec injection hose system

valid as of 1 April 2014 Intec injection hose system FRANK Product List valid as of 1 April 2014 Intec injection hose system Intec injection hose systems Intec injection hose systems ensure secure, simple and rapid sealing of horizontal and vertical construction

More information

Ultipleat High Flow Filter System

Ultipleat High Flow Filter System Data Sheet PIUFFSENa Ultipleat igh Flow Filter System Description The Ultipleat igh Flow filter is a large diameter, coreless, single open ended, pleated cartridge with an inside-to-outside flow pattern.

More information

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves 1. General company and product information 2. Flanged gate valves for water 3. Other gate valves for water 4. Combi valves 5. Service connection valves for water 6. Valves and fittings for gas 7. Fire

More information

SEPTIC TANKS FOR THE COLLECTION & SETTLEMENT OF DOMESTIC SEWAGE

SEPTIC TANKS FOR THE COLLECTION & SETTLEMENT OF DOMESTIC SEWAGE SEPTIC TANKS FOR THE COLLECTION & SETTLEMENT OF DOMESTIC SEWAGE Let us help! Free professional site visit with friendly support and advice. [email protected] to make the right decision or call

More information

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT The following are minimum requirements for installation of conventional trench sewage disposal systems in St. Mary s County,

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

How To Get A Flood Risk Reduction Rebate

How To Get A Flood Risk Reduction Rebate 1. Address Number of Property 2. Street Name of Property 3. Last Name 4. First Name 5. Phone Number 6. Preferred time to be contacted o Morning o Afternoon o Evening preference 7. Email Address 8. Are

More information

Home Drainage & Causes of Basement Flooding. Water

Home Drainage & Causes of Basement Flooding. Water Home Drainage & Causes of Basement Flooding Understanding Drainage There are two separate sewer systems Eavestroughs & Downspout Road Property Line Floor Drain Catch basin Access Cover Weeping Tile House

More information

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions. SECTION LS 2530 SANITARY SEWERS PART 1 GENERAL 1.1 SUBMITTALS A. General: Submit the following in accordance with The General Conditions. 1. Product data for drainage piping specialties. 2. Shop drawings

More information

At the end of today s seminar you should be better. Recognize the causes of Sewer Lateral backup. Identify techniques to protect your home from

At the end of today s seminar you should be better. Recognize the causes of Sewer Lateral backup. Identify techniques to protect your home from Preventing Sewer Backups Presented by IAPMO Today s Objectives At the end of today s seminar you should be better able to: Recognize the causes of Sewer Lateral backup Identify techniques to protect tyour

More information

SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS

SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS PART 1: GENERAL 1.01 COORDINATION OF WORK Connection to existing pipelines may require shutdown of AW facilities. Closely coordinate construction work

More information

foundation designed to keep water out of the basement.

foundation designed to keep water out of the basement. Preventing Sewer Backups To safeguard your home against flooding from sewer backups, you should understand your home's basic plumbing and the preventative techniques discussed in this brochure. Basement

More information

4" SUBMERSIBLE PUMPS

4 SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 50/60 HZ Multi-stage centrifugal submersible pumps for clean water in 4" wells. The 4" VSP pump series is carefully designed and manufactured for maximum resistant

More information

City of Edmonton Page 1 of 5 Foundation Drain Discharge Collection System Guideline November, 2005

City of Edmonton Page 1 of 5 Foundation Drain Discharge Collection System Guideline November, 2005 City of Edmonton Page 1 of 5 This guideline will apply to all new developments involving singledetached, semi-detached or duplex houses in the City of Edmonton effective January 1, 2006. Preamble: This

More information

SECTION 33 41 13 PUBLIC STORM UTILITY DRAINAGE PIPING

SECTION 33 41 13 PUBLIC STORM UTILITY DRAINAGE PIPING SECTION 33 41 13 PUBLIC STORM PART 1 - GENERAL 1.01 SECTION INCLUDES A. Storm drainage piping, fittings, and accessories at proposed station areas and locations other than under and immediately adjacent

More information

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere.

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere. SANITARY & WASTE WATER PUMPING SYSTEMS Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere. Wallace Pumps solve all those waste disposal problems, big or small, with

More information

Transport and Main Roads Specifications MRTS25 Steel Reinforced Precast Concrete Pipes

Transport and Main Roads Specifications MRTS25 Steel Reinforced Precast Concrete Pipes Technical Specification Transport and Main Roads Specifications MRTS25 Steel Reinforced Precast Concrete Pipes September 2014 Copyright http://creativecommons.org/licenses/by/3.0/au/ State of Queensland

More information

ELECTRIC PERISTALTIC MORTAR POINTING PUMP

ELECTRIC PERISTALTIC MORTAR POINTING PUMP ELECTRIC PERISTALTIC MORTAR POINTING PUMP pointing gun & control valve ACF405 PERISTALTIC PuMP hopper feed roller & tube pump for refurbishment & repair trades heritage & conservation bridge & underground

More information

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description Style 07 Zero Flex Rigid Coupling The unique angled pad design adjusts to standard pipe tolerances to positively clamp the pipe to resist flexural and torsional loads. Working pressures are based on standard

More information

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO) SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO) 1 Intent: The intent of trenchless sewer pipe Insertion is to rehabilitate the existing sewer

More information

DUBLIN CITY COUNCIL FLOOD FORUM

DUBLIN CITY COUNCIL FLOOD FORUM DUBLIN CITY COUNCIL FLOOD FORUM PROPERTY FLOOD PROTECTION GUIDE DCC Customer Services (Drainage) DCC Flood Forum Tel: 222 0700 Tel: 222 3294 DCC Afterhours Tel: 679 6186 0 Rev 1 Aug 2013 DUBLIN CITY COUNCIL

More information

ACO Water Management: Civils + Infrastructure

ACO Water Management: Civils + Infrastructure ACO Water Management: Civils + Infrastructure Technical data Introduction to The unit provides an aesthetically pleasing solution when linking proprietary conveyance drainage systems to vegetated infiltration

More information

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials. PART 1 GENERAL 1.1 SCOPE A. This item shall include the work necessary for the installation of storm sewer line construction. B. Reference Section 3800 Trenching and Backfill and the General Conditions,

More information

ROOF DRAINS TABLE OF CONTENTS

ROOF DRAINS TABLE OF CONTENTS Pictorial Index Product Recommendations Roof Drain Selection Factors Sizing Placement Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations TABLE OF CONTENTS ROOF

More information

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors. SUBDRAINS AND FOOTING DRAIN COLLECTORS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Subdrains B. Subdrain Cleanouts and Outlets C. Footing Drain Collectors D. Storm Sewer Service and Connections 1.02 DESCRIPTION

More information

RUBBER SLEEVE KNIFE GATE VALVE

RUBBER SLEEVE KNIFE GATE VALVE RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a wafer valve designed for a wide range of industrial applications. The double-seated design provides bi-directional shut off. The design of the valve

More information

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance 02/15 Labko GRP cesspools Instructions for installation, operation and maintenance Reliable solutions Wastewater treatment systems Contents 1 LABKO CESSPOOLS... 3 1.1 GENERAL... 3 1.2 IMPORTANT TO KNOW

More information

EWE Ball Valve-Type Tapping Valve. EWE Ball-Type Tapping Valve. EWE GBM Tapping Valves. for water and gas

EWE Ball Valve-Type Tapping Valve. EWE Ball-Type Tapping Valve. EWE GBM Tapping Valves. for water and gas The following overview shows the different EWE tapping valves to help you to make your choice: EWE valve tapping valve for vertical tapping with operating shut-off, for all types of pipe, with external

More information

Top 10+ Mistakes of DWV plumbing design

Top 10+ Mistakes of DWV plumbing design Top 10+ Mistakes of DWV plumbing design Listed below are the some of the most frequently missed items, noticed by our inspectors, at plumbing rough-in when non-plumbers attempt plumbing design. Most of

More information

Protect your home from basement flooding

Protect your home from basement flooding Protect your home from basement flooding It's important to protect your home from basement flooding because your home could be at risk of basement flooding. Why? Heavy rainstorms that fall over short periods

More information

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING 60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed

More information

SECTION 02612 NONREINFORCED CONCRETE SEWER PIPE

SECTION 02612 NONREINFORCED CONCRETE SEWER PIPE SECTION 02612 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Furnishing and installing nonreinforced concrete sewer pipe. Provide concrete sewer pipe less than 12 inches in diameter, and in other sizes

More information

08.08 Vic-Check Valves

08.08 Vic-Check Valves The check valves are a product of computer-assisted innovative engineering with quality features including a new hydrodynamically efficient profile. The Vic-Check valve utilizes a spring-assisted, single-disc

More information

V47 Series Temperature Actuated Modulating Water Valves

V47 Series Temperature Actuated Modulating Water Valves V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

UNIVERSITY OF CHICAGO ELEVATOR PIT LEAK REPAIR

UNIVERSITY OF CHICAGO ELEVATOR PIT LEAK REPAIR ITEM: UNIVERSITY OF CHICAGO ELEVATOR PIT LEAK REPAIR DESCRIPTION: General Furnish all labor, equipment, and materials necessary and incidental thereto to perform all required operations to eliminate the

More information

SECTION 221413 FACILITY STORM DRAINAGE PIPING

SECTION 221413 FACILITY STORM DRAINAGE PIPING SECTION 221413 FACILITY STORM DRAINAGE PIPING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

SANITARY SEWER SPECIFICATIONS

SANITARY SEWER SPECIFICATIONS SANITARY SEWER SPECIFICATIONS OCTOBER 2003 HARVEST-MONROVIA WATER, SEWER, AND FIRE PROTECTION AUTHORITY SECTION 1.00 1.10 Purpose The purpose of this document is to assemble the sewer specifications, policies,

More information

Flygt Ball Check Valves

Flygt Ball Check Valves 4/13 Supersedes: 6/96 The basic purpose of a check valve is to permit flow in one direction, prevent flow in the opposite direction and perform this function automatically and with minimum maintenance.

More information

a guide to PREVENTING HOME FLOODING DURING STORMS

a guide to PREVENTING HOME FLOODING DURING STORMS DISTRICT OF COLUMBIA WATER AND SEWER AUTHORITY a guide to PREVENTING HOME FLOODING DURING STORMS DCWATER.COM Updated August 15, 2012 Flooding can damage District homes and businesses. It results when the

More information

SECTION 02110 - ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL

SECTION 02110 - ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL SECTION 02110 - ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL PART 1 - GENERAL 1.1 WORK INCLUDED IN THIS SECTION A. The WORK of this Section includes the repair, demolition, and disposal of asbestos

More information

Sampling Solutions. Fuel and Lube Oil sampling Equipment. Convenient, Representative, Approved.

Sampling Solutions. Fuel and Lube Oil sampling Equipment. Convenient, Representative, Approved. Sampling Solutions Fuel and Lube Oil sampling Equipment. Convenient, Representative, Approved. Oil Samples are used to obtain a clear indication of the operating status of your machinery. One of the most

More information

1-800-327-8276 www.jfcson.com

1-800-327-8276 www.jfcson.com Trenchless Cost Effective Internal Pipe Rehabilitation 101 East Broadway, Hackensack, N.J. 07601 Folsom, NJ Linden, NJ Beltsville, MD Sylmar, CA 1-800-327-8276 www.jfcson.com In-Weg Internal Joint Sealing

More information

CAVITY DRAIN MEMBRANE SYSTEMS: SUMPS AND PUMPS GUIDANCE NOTES

CAVITY DRAIN MEMBRANE SYSTEMS: SUMPS AND PUMPS GUIDANCE NOTES CAVITY DRAIN MEMBRANE SYSTEMS: SUMPS AND PUMPS GUIDANCE NOTES Introduction: In most cases when installing the Isola Platon cavity drain system the actual level of water ingress or potential level of water

More information

SUMP PUMP. City of Ann Arbor & C O L L E C T I O N S Y S T E M G L O S S A R Y

SUMP PUMP. City of Ann Arbor & C O L L E C T I O N S Y S T E M G L O S S A R Y Foundation A foundation is the bottom part of a building. It s the element that anchors the building to the ground and transmits the building s gravity load directly to the earth. Water damage weakens

More information

Hunter Plastics Ltd Nathan Way London SE28 0AE Tel: 0181-855 9851 Fax: 0181-317 7764

Hunter Plastics Ltd Nathan Way London SE28 0AE Tel: 0181-855 9851 Fax: 0181-317 7764 CI/SfB (52.9) Xn6 Designated by overnment to issue European Technical pprovals Product THIS CERTIFICTE REPLCES CERTIFICTE No 83/1066 ND RELTES TO THE HUNTER NOUEU IR DMITTNCE LE ND HUNTER NTI-SIPHON UNIT,

More information

A Guide to Flood Resilient Repairs

A Guide to Flood Resilient Repairs A Guide to Flood Resilient Repairs A Guide to Flood Resilient Repairs Some five million people live under the threat of flooding that s one in ten houses in the UK and 200,000 are very high risk. This

More information