WAFER GSM-TOG REMOTE CONTROL UNIT GSM-TOG MANUAL SHANGHAI WAFER MICROELECTRONICS CO.,LTD.
|
|
|
- Rodney Newton
- 9 years ago
- Views:
Transcription
1 GSM-TOG MANUAL SHANGHAI WAFER MICROELECTRONICS CO.,LTD
2 GSM-TOG OPERATING INSTRUCTIONS PRODUCT DESCRIPTION HUOBEI GSM-TOG is an electronic board with an on-board GSM modem.the purpose of this device is to do the real time and interactive GSM remote control from authorized phone numbers. GSM-TOG has three big power relay output,maximum switching power up to 6000W,and also it has three alarm input port. On board rechargeable battery can monitor the power change for emergency alarm. CONNECTOR DESCRIPTION Three relay output from RELAY1 (NC1,NO1,COM1), RELAY2 (NC2,NO2,COM2), RELAY3 (NC3,NO3,COM3) Three alarm input port from IN1 to IN3 (only for Switch type alarm input) Power input:dc9-36v or DC18-72V (Regardless of polarity) ADVANTAGES OF HUOBEI GSM-TOG ˇ 3 channels 230V 30A 50Hz relay contacts. ˇ 3 channels Alarm input port. ˇ Battery on board for power off alarm ˇ No call charges to operate from phone calling. ˇ Work with GSM phones calling and SMS or any other phone calling ˇ Relay operates almost every electric applicance. ˇ Remote password operation and also password change. ˇ Opetional relay working mode
3 ˇ Each relay can be selected for phone calling control or SMS control ˇ Caller ID confirmation for security ˇ Quick & easy number barring. ˇ Can be operated from anywhere. ˇ Easy programming in minutes with your phone or PC software ˇ Device operation record log is saved in the memory for checked INSTALLATION Before installation,the below picture show the on board description: Status LEDs: D2: SMS LED,when receiving or sending the SMS,this LED should be flashing D4: MCU working status LED D6: GSM net LED,when connected to the GSM net,it would start to flash slowly around three second per tim Battery LED: D12 Teach LED: D5 To install the GSM-TOG, you need to power on the board with DC 9V-36V(Optional is DC18-72V and AC V). and also connect the relay output according to your project. The relay contacts can stand 230V 30A maximum, this is enough for its operation but don't try to switch higher voltages or currents. You should install the GSM-TOG in a place where there is GSM signal coming from the operator you want to use. Check it with a phone before proceeding with the installation. If you need to install the device in a place with little signal, you may consider using an external antenna that we may supply as an option to be purchased separately with 50cm cable. You should then insert the SIM Card of the operator you want to use with the right direction according to the following pictures.
4 !Note! : You must remove the PIN request from the SIM before inserting it in the unit, otherwise the device will not work. In order to do so, insert the SIM in a phone and disable the PIN request (usually there is a security menu that enables you to do so). Backup rechargeable battery power input 1.Slide back the SIM door and lift it up 2.Slide the SIM Card into the SIM door making sure that the clipped corner of the SIM card lines up with the clipped corner of the SIM holder 3.Close the SIM door 4.Slide the SIM door to lock the SIM card in place For GSM-TOG controller,we use the Rechargeable lithium ion battery (the same type battery that is mostly used in the mobile phone) Normally HUOBEI will provide the battery inside the box,but later If customer make the battery connector at the site,please take care of the polarity HUOBEI GSM-TOG PROGRAMMING You can program the GSM-TOG with SMS commands using your phone. It is safe to do so because in addition to the fact that other people may not know the number of the SIM inserted in it, we also use a Password that makes it impossible for anybody who doesn't know it to access the system by chance.(of course if you select the ACM=OFF free control mode,then any number can control the device with phone calling) There are three LED: D2 D4 D6 on the board. That is used to show the working status of the device. D6 is used to show the GSM Module working status, D4 is used to show the MCU controller working status, D2 is used to show SMS receiving and sending status, D2 will flash quicly to show the incoming message and also following three slow flash to show the sending out reply SMS. Normally D6 is flashing quickly when power up and after about some minutes,it will go to flash slowly about 3 seconds per time when the SIM card connected to the GSM net. Remember that commands must be CAPITAL LETTERS. It is PWD not pwd, CAP not Cap etc. Don't add spaces or any other character. Some complicated Instructions,that cann t be programmed by the phone SMS. That would
5 need to use the PC software to program and inquiry the status of the terminal. Simply use the USB cable connect the device to the computer and installing the USB driver (you can get the driver from HUOBEI company or our distributor) The following compand is used in the GSM-TOG : #PWD: Password #CAP: Change password #WHL: White List (add or remove numbers) #QUERY: Use the command to check the exact positon in the WHL numbers list #ACM: Free control mode or safety control mode selection #REPORT: Device Status change report #REPLY: When get the SMS relay control command,if need to reply the SMS #CHOOSE: Select which relay is under control with phone calling #GOT: Relay working output delay time #ALARM: Alarm information setting #MODE: Relay mode #CSQ: Check Signal Quality #SCA: Set service center address #STATUS: Check status #RERN: Alarm number enabled and each alarm switch is ON or OFF #OUT: Switch ON or OFF the relay #RLY: Temporarily timing control the relay ON or OFF #UDI: Alarm SMS Text defined Once you issue a command with an SMS, you will receive a confirmation SMS with OK if everything is correct or Command Error if there is an Error command. GSM-TOG SMS COMMAND LIST: #PWD Password. This command must always come first 6 digits as a password. The standard default one, when the device comes from the factory, is We suggest that you change it, using the #CAP command. In all the following examples we will use as an example of password. #CAP Change Password. Use this command to change the password with a new one that you will chose for your device ( don't forget it or you will have to send the unit back to us to reset it, and this has a cost ) The #CAP command must be issued 2 times to be sure you don't digit a wrong one. OF course it must be preceded by the old password. For example, to change the password into the new password you need to send the following SMS: #PWD123456#CAP333444#CAP333444
6 Acknowledge SMS: PWD SETUP OK If you wrote correctly, or an Error message if you made a mistake. If the old password is error,then conformation would be : Error Old Password If you input two different new password,then reply would be : Error New Password,Please Check the input again #ACM Safety control or free control mode setting. (PC$PHONE) #PWD123456#ACM=ON #PWD123456#ACM=OFF ACM=OFF, Then any number can free control the device through the phone calling ACM=ON, Then only the authorized number can control the device through the phone calling #WHL White List. This is the command that you will use most. it is used to add or remove numbers that are enabled to control the relay sets into the White List. You can add up to 200 numbers in the list. Every position must be indicated in the command and we advise you to keep a list written somewhere to know which numbers are in and in which position.you also can use the QUERY to know the exact position of one phone number. For WHL number programming,you can use the Fast teaching button to do if you don twant to send the SMS one by one. Of course,fast teaching button only can be used to program the number from WHL01 to WHL Use the fast Teach Button (JP3) to program Press the Teach button and hold the button for around 2 second, the LED D7 would be lit,and then use your phone to call the device number. when coming the call, the device would reject the calling and D5 would flash one or two times, then the number is saved into the device memory, if you need to program more, then just continue to use other phones to call the device. After program, press the button again to quit the teaching. then the LED D5 would be extinguished. (Fast button only program WHL position from WHL01 to WHL10) 2. Use the SMS to program To add a number, the syntax of the command is the following: #PWD123456#WHL02= Acknowledge would be : WHL02 SET TO OK Where 02 is the position in the list and is the number enabled. Please note that it is possible to program up to a maximum of 10 digits for a number. If it has more digits you should use the rightmost ones. For example, if your number is you should program If your number appears as you should not program the country code (+852). If your number has only 9 digits or less, it is not a problem. The important thing is that you don't exceed 10 digits. Important Note: From WHL01 to WHL08,that is Special numbers for Control and Alarm SMS receiving Especially for WHL01, that is also a System data change REPORT number So that would be better to setup your normal Control number from WHL09 to WHL200 To check which is the number in a place of the list:
7 #PWD123456#WHL05? Acknowledge : WHL05 IS OK To erase a number: #PWD123456#WHL05=0000 (or you can write over it another number you wish to add) Acknowledge : WHL05 SET TO List All numbers in the List #PWD123456#WHL=ALL? (PC) Acknowledge : WHL02 IS XXX WHL03 IS XXX WHL08 IS XXX #QUERY White List. #PWD123456#QUERY=xxxxxx This is used to check if a number is inside the WHL or not and the WHL positon #REPORT Report the system status change (PC$PHONE) When setup to: #PWD123456#REPORT=ON Then any device status change would send the alarm SMS to Alarm01 number #PWD123456#REPORT=OFF No report for the device status change #PWD123456#REPORT? Check the REPORT setting status FOR PHONE CALLING OUTPUT CONTROL #GOT Relay working output delay time. When setup the GOT Timer,first you need to setup the timer multiplier at millisecond or second or minutes. #PWD123456#TIMER-DELAY-AT-MILLISECOND #PWD123456#TIMER-DELAY-AT-SECOND #PWD123456#TIMER-DELAY-AT-MINUTE Then you need to setup the GOT timer number: This command is useful in case you need to keep the Relay output working longer. The standard time is 0,3 seconds (300 ms). You can change it with the GOT command. The syntax of the command is the following: #PWD123456#GOTX=xxx (PC$PHONE) (for Relay1,relay2 and relay3) #PWD123456#GOT1=900 (#PWD123456#GOT2=900, #PWD123456#GOT3=900 ) Acknowledge: GOT1 DELAY TIME SET TO 0900S With the above command the delay time has been set to 900 s You also can setup to GOT2,GOT3 for Relay2 and Relay3 You can check what the current relay output delay time is with the command #PWD123456#GOT? (PC$PHONE) Timer is for second
8 Acknowledge: GOT1=02,GOT2=05,GOT3=05 #MODE Relay Operation Mode SETUP (PC$PHONE) (for Relay1,Relay2,Relay3) #PWD123456#RELAY1=MODE0 (for Relay1,Relay2,Relay3) Acknowledge: RELAY SET TO MODE0 #PWD123456#RELAY1=MODE1 (for Relay1,Relay2,Relay3) Acknowledge: RELAY SET TO MODE1 If set to MODE0,that is Momentary pulse and If Config to MODE1,that is Ratchet relay When you want to phone call to trigger different relay,then would need to use the SMS to switch to this relay #PWD123456#CHOOSE=100 Use the above command to select the Relay that can be controlled with the phone calling From the left to right is for RELAY1 to RELAY3,and 1 is under control and 0 is free of control For example setup to #PWD123456#CHOOSE=110,Then only relay1 and relay2 is under control Acknowledge: CHOOSE=110 #PWD123456#CHOOSE? Acknowledge: CHOOSE= FOR SMS OUTPUT CONTROL #REPLY SMS reply OFF or ON #PWD123456#REPLY=ON When setup to ON,then Device will reply the OUT and RLY command after Relay is toggled #PWD123456#REPLY=OFF When setup to OFF,then Device will not reply the OUT and RLY command after Relay is toggled (This command is used to save the cost for user) #OUT Relay output control (1)ON the relay output contact #PWD123456#OUTX=ON (PC$PHONE) Where X is the number of the relay in the list (X is from 1 to 7) Acknowledge: OUTX ON OK (2)OFF the relay output contact #PWD123456#OUTX=OFF (PC$PHONE) Where X is the number of the relay in the list (X is from 1 to 7) Acknowledge: OUTX OFF OK (3)ALL the relay control at the same time #PWD123456#OUT=111 (PC$PHONE) Where the number is 1 or 0 to ON or OFF the relay. Acknowledge: #PWD123456#OUT=111 OK (4)Trigger the output relay for some seconds #PWD123456#RLY1=XXX #PWD123456#RLY2=XXX #PWD123456#RLY3=XXX
9 Acknowledge: #RLY1-ON: xxxx #RLY2-ON: xxxx #RLY3-ON: xxxx (5)Check the relay status #PWD123456#OUT? (PC$PHONE) Acknowledge: OUT 111 (the Number 1 means RELAY ON and 0 means RELAY OFF) #PWD123456#RELAY? Acknowledge: RLY1=RLY,RLY2=OFF-RLY,RLY3=OFF-RLY,RELAY1=MODE0:02,RELAY2=MODE0:0 5,RELAY3=MODE1:05 #CSQ Check GSM signal quality. (PC$PHONE) This command is useful to see what is the GSM network signal level your GSM-TOG is receiving. It ranges from 0 to 32 (if it is 0 we doubt it will ever answer...). You should have a signal above 12 to be sure of being able to control the relay sets in any condition. Better if above 16. You should add an external antenna if this is not the case, or eventually even change operator with another that serves your area better. #PWD123456#CSQ? Acknowledge: CSQ IS ALARM SETUP (5) Config the Customized Alarm SMS TEXT for input Alarm: (PC) #PWD123456#UDI1:ABC1,UDI2:ABC2,UDI3:ABC3 Acknowledge: UDI1:ABC1,UDI2:ABC2,UDI3:ABC3 OKAY (When the Alarm input is triggered,will send this customized SMS) Check the text set #PWD123456#UDI? Acknowledge: UDI1:ABC1, UDI2:ABC2 (5) Enable the alarm phone number #RERN Enables the administrator to receive the alert SMS This is the command that allows you to enable, disable and check the status of the administrator list, these are the number that will receive system alerts SMS. In the first 8 numbers of the WHL numbers list,from WHL01 to WHL08, that is administrator numbers, To allow the first 4 administrators in the Administrator List to receive system alerts SMS only,you would send the follow SMS text command to the unit. #PWD123456#RERN= :PWA=ON,REYA=ON,OUTA=ON,CSQA=ON Where 1 is a number enabled for the first 4 positions in the administrator list,and 0 is a number disabled for the last 4 positions in the list. You will receive the following confirmation from the unit RERN IS SETUP TO :PWA=ON, REYA=ON,OUTA=ON,CSQA=ON
10 and the first four administrator numbers in the list the receive SMS text alerts PWA=ON : When power is changed, will send the alert message REYA=ON : When use the RLY to change the relay status,would send the alert message OUTA=ON: When the out1 or out2 status is changed,then would send the alert message CSQA=ON:When the CSQ is lower than a configured data,then would send the alert message To check the status of the RERN list you would send the following S.M.S message to the unit #PWD123456#RERN? You will receive the following similar confirmation from the unit RERN: :PWA=ON, REYA=ON, OUTA=ON,CSQA=ON Enable or disable the input alarm: #PWD123456#ALARM-IN1=ON:2,ALARM-IN2=OFF,ALARM-IN3=ON:2 Acknowledge: ALARM-IN1=ON:2,ALARM-IN2=OFF,ALARM-IN3=ON:2 OKAY Then the ALARM-IN1 and ALARM-IN3 is enabled and ALARM-IN2 is disabled CSQ alert data setup: #PWD123456#CSQA=19 When the CSQ is lower than the Configed data,then would send the alert SMS: GSM SIGNAL LOWER THAN 19,PLEASE CHECK IT #PWD123456#CSQA? Acknowledge: CSQA IS 22 Battery working and alarm System Alert SMS: BATTERY WORKING STATUS,PLEASE CHECK When battery working,any SMS command coming,device would reply this STATUS and RESET #STATUS? Check system status This command is useful to check the system parameters and the inside clock. #PWD123456#STATUS? You will receive the following similar confirmation from the unit ACM=ON,RELAY1=MODE0:05,RLY1=OFF-RLY,RLY2=OFF-POWER,RLY3=OFF-RL Y,RERN: ,PWA=ON,REYA=ON,OUTA=OFF,CSQA=ON System RESET command (Send from the PC software) GSM-TOG-RESET GSM-TOG-RESET OKAY After Reset: All numbers would be cleared TIMER-DELAY-AT-SECOND ACM=ON,REPORT=OFF,REPLY=ON,RELAY1=MODE0:0005, RELAY2=MODE0:0005,
11 RELAY3=MODE0:0005, PWA=ON,REYA=OFF,OUTA=OFF,CSQA=OFF System on board reset button Press the Teach button and hold the button or more than 10 seconds,then the LED D5 would start to flash to RESET the device.and then release the button. Troubleshooting No LED is on after power up Check the power supply. Check the wires is connected well. GSM LED D6 is not flash slowly (GSM LED normally flash quickly when power off and when it connected to GSM net,then would flash around two seconds per time). Check your ordered device if that is the proper GSM BAND to your country.don t use the 3G card to test (including CDMA2000 or WCDMA is not suitable) Check the SIM card is properly inserted. Check the PIN.(Normally don t need to check, if SIM card can work with your mobile phone.) Check the antenna connection is fitted well. GSM Signal is not good and cann t register to GSM,try to move to another place to test. If still cann t registered to the GSM net, try to contact HUOBEI to get the technical support When LED D6 is flashing slowly,try to call the SIM card,the calling status would be in busy. MCU LED D4 is not flash slowly MCU is not working properly,check the system power No Relay working tone can be heard when phone calling the device Check if your Control number is already setup into the device. GSM-TOG is not initialized properly upon start (approx. 10s after power up). If the GOT timer is setup to a very short timer ( normally should be more than 500ms ) GSM-TOG does not communicate with PC Check the serial cable connection. Check the COM number setting on PC. Check if you select the New Line selection box Check if you input the right instruction line and that should be all use the Capital word, Check the COM parameters (9600 bps, 8N1).
12 An incoming call is ringing on GSM-TOG An incoming SMS message is on processing by GSM-TOG Relay connection example to Output Driver The relay control outputs are suitable to control different household and other devices as are air-conditioning and heating,connected directly or through external relay modules. The relay has NO and NC contacts,normally,we only need to use the NO and COM contacts. Note: Power supply for the each load mustn t exceed 30VDC/30A or 230VAC/30A Warning: GSM-TOG device is only working as a high power switch, don t power the LOAD directly.
13 This brochure provides an overview of the products and services of HUOBEI GSM Modules, For further information and queries kindly contact: Web: Tel: Copyright 2015, WAFER GSM V V1.1
WAFER GSM-RELAY REMOTE CONTROL UNIT GSM-RELAY MANUAL SHANGHAI WAFER MICROELECTRONICS CO.,LTD. http://www.waferstar.com
GSM-RELAY MANUAL SHANGHAI WAFER MICROELECTRONICS CO.,LTD GSM-RELAY OPERATING INSTRUCTIONS PRODUCT DESCRIPTION WAFER GSM-RELAY is an electronic board with an on-board GSM modem.the purpose of this device
WAFER GSM-KEY REMOTE CONTROL UNIT GSM-KEY MANUAL AC200 VERSION 5.0 SHANGHAI WAFER MICROELECTRONICS CO.,LTD. http://www.waferstar.
GSM-KEY MANUAL AC200 VERSION 5.0 SHANGHAI WAFER MICROELECTRONICS CO.,LTD PRODUCT DESCRIPTION GSM-KEY OPERATING INSTRUCTIONS WAFER GSM-KEY is an electronic board with an on-board GSM modem.the purpose of
EST-64 GSM Remote Control Device User Manual E E S S T T A A T T E E S S W W I I N N G G
EST-64 GSM Remote Controll Deviice User Manual EESSTTAATTEE SSWIINNGG Electronic KIT to convert your gate into a GSM gate EST-64 GSM Remote Control Device Diagram 2 1. INTRODUCTION EST-64 GSM Remote Control
WAFER GSM REMOTE CONTROLLER GSM-AUTO INSTALLATION MANUAL
WAFER GSM REMOTE CONTROLLER GSM-AUTO INSTALLATION MANUAL Copyright: SHANGHAI WAFER MICROELECTRONICS CO.,LTD GSM-AUTO VERSION 1.1-1209 GSM-AUTO REMOTE CONTROL Installation and Operation Instructions IMPORTANT!
GSM Controller User manual
GSM-AUTO GSM Controller User manual INDEX Description... 2 Preparing the SIM card... 3 Installation... 4 Example connections... 5 Programming commands... 7 Quick reference of programming commands....12
GSM Gate Opener GSM Remote Switch RTU5015. User Manual. Ver 1.1 Date Issued: 2009-12-18. All rights reserved by King Pigeon Hi-Tech. Co., Ltd.
GSM Gate, Barrier, Shutter, Garage Door and Door opener Open gate or garage door with a FREE call from your mobile phone! Remote switching machines with a FREE call from your mobile phone! GSM Gate Opener
GSM Gate Opener GSM Remote Switch RTU5015 User Manual
GSM Gate, Barrier, Shutter, Garage Door and Door opener Open gate or garage door with a FREE call from your mobile phone! Remote switching machines with a FREE call from your mobile phone! GSM Gate Opener
GSM-AUTO+ GSM Controller with Internal Power Supply User manual
GSM-AUTO+ GSM Controller with Internal Power Supply User manual INDEX Description... 2 Preparing the SIM card... 3 Installation... 4 Example connections... 5 Programming commands... 6 Quick reference of
GSM Gate Opener GSM Remote Switch RTU5015. User Manual. Ver 1.3 Date Issued: 2010-08-18. All rights reserved by King Pigeon Hi-Tech. Co., Ltd.
GSM Gate, Barrier, Shutter, Garage Door and Door opener Open gate or garage door with a FREE call from your mobile phone! Remote switching machines with a FREE call from your mobile phone! GSM Gate Opener
Business/Home GSM Alarm System. Installation and User Manual
Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene
GSM Alarm System User Manual
GSM Alarm System User Manual For a better understanding of this product, please read this user manual thoroughly before using it. Quick Guider After getting this alarm system, you need to do the following
MANUAL GSM CONTROLLER
MANUAL GSM CONTROLLER CallFree2 CallFree 3G 2 outputs, 3 inputs ` Please read these instructions completely before use GSM CallFree 1/17 Revision V1.3C, Aug 2015 TABLE OF CONTENTS 1. SAFETY PRECAUTIONS...
GSM Gate Opener GSM Remote Switch
GSM Gate, Barrier, Shutter, Garage Door and Door opener Open gate or garage door with a FREE call from your mobile phone! Remote switching machines with a FREE call from your mobile phone! GSM Gate Opener
STATUS POWER MONITOR ALARM SOS DISARM
STATUS POWER MONITOR ALARM SOS DISARM I. Features II. Preparation before use III. Host 1.LED status explanation 2. Host panel IV. System Settings 1. Coding of wireless sensors 2. Exit coding 3. Settings
New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.
New GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Chapter 1. Features Chapter 2. Alarm Host Introduction Chapter
GSMPBX version 1.3 Datasheet
GSMPBX version.3 Datasheet Document Rev.:.3 Revision Date: 23.03.203 (preliminary data) Figure - GSMPBX Introduction The GSMPBX is designed to commute phone calls between a cellular network (GSM) and the
TX GSM SMS Auto-dial Alarm System. Installation and User Manual
TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses
WITURA CORPORATION SDN BHD
WT 1010SA Stand Alone GSM Alarm System User Manual and Installation Instructions Version: 1.2 Updated: 4 JAN 2012 WITURA CORPORATION SDN BHD Stand Alone GSM Alarm System Instruction Manual 1 Introduction:
The GD-04K universal GSM communicator and controller
The GD-04K universal GSM communicator and controller The GD-04K is a universal GSM communicator. It controls and / or reports status of different appliances remotely. Control can be performed by SMS instructions
SMS GSM Alarm Messenger
SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up
GSM HOME SECURITY SYSTEM
Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : GSM-120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5.
GSM Autodialer Professional GJD700 Speech & Text Autodialer
Text Edit message GSM Autodialer Professional GJD700 Speech & Text Autodialer Introduction The GSM Autodialer Professional works in conjunction with standard alarm systems and makes use of your preferred
SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision 090210 [Version 2.2]
SMS Alarm Messenger SMSPro_Setup Revision 090210 [Version 2.2] ~ 1 ~ Contents 1. How to setup SMS Alarm Messenger?... 3 2. Install the SMSPro_Setup software... 5 3. Connection Type... 6 4. Connection Port
Configuring the Siemens TC35 modems for use with the MI2292
Configuring the Siemens TC35 modems for use with the MI2292 The following instruction describe how to set up GSM communication between an MI2292 Power Quality Analyser Plus and a computer 1. Equipment
CCTR-800 Portable Real Time GPS Tracker
CCTR-800 Portable Real Time GPS Tracker Welcome to use Real Time GPS tracker CCTR-800, This product is with GPS module and GSM module, It has many new and unique functions, such as real time uploading
CCTR-805-V2 3G Car GPS Tracker-201604
CCTR-805-V2 3G Car GPS Tracker-201604 Welcome to use this real time car GPS tracker CCTR-805G.This product is with GPS module and 2G GSM / 3G WCDMA module (with LBS locate without GPS), that has many new
Intelligent GSM Auto-dial Alarm System User s Manual
Intelligent GSM Auto-dial Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. [Function Instruction] [Control Panel Introduction]
Security module CG2 User manual
Security module CG2 User manual TRIKDIS, JSC Draugystes str. 17, LT-51229 Kaunas LITHUANIA E-mail [email protected] Web http://www.trikdis.lt This manual is furnished to help You understand Your security
INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM
INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM Revised: August 28, 2014 PRODUCT REFERENCE MOUNTING ACCESSORIES PIR / MOTION DETECTION UNIT MAIN UNIT POWER ADAPTER MOUNTING ACCESSORIES
User Manual. Genius GPS / GSM 810 Real Time GPS Tracker. Android App Download. Iphone App Download ENGLISH. Genius Advanced Technologies
Genius GPS / GSM 810 Real Time GPS Tracker User Manual Android App Download Iphone App Download www.geniuscaralarm.com 1 Genius GPS / GSM 810 Real Time GPS Tracker Welcome to use this real time car GPS
GSM ATT Modules Simply effective remote control
GSM ATT Modules Simply effective remote control To control electrical loads via mobile phone The benefits Remote management of electrical devices is an increasingly widespread requirement in residential
Operating Instructions
Operating Instructions Kühn Controls AG, Gräfenhäuser Str. 14, D-75305 Neuenbürg, Germany Tel. +49 (0)7082-94 00 00 www.kuehn-controls.de [email protected] Fax +49 (0)7082-94 00 01 Content 1. SMS
GSM Temperature Alerter. User Manual. Manual version 1.0
GSM Temperature Alerter User Manual Manual version 1.0 This brochure suits for 19-0415 model. 19-0415 GSM Temperature Alerter USER MANUAL 19-0415 GSM Temperature Alerter Thank you for purchasing the 19-0415.
How To Program An Autodialer
GJD HYL005 GSM Autodialer Instruction Manual Please read these instructions before you start the installation Features: LCD display. Programmable 9 x 32 digit phone numbers for each trigger. 10 second
USB GSM 3G modem RMS-U-GSM-3G. Manual (PDF) Version 1.0, 2014.8.1
USB GSM 3G modem RMS-U-GSM-3G Manual (PDF) Version 1.0, 2014.8.1 2014 CONTEG, spol. s r.o. All rights reserved. No part of this publication may be used, reproduced, photocopied, transmitted or stored in
Memcom Emergency Telephone
Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming
F2103 GPRS DTU USER MANUAL
F2103 GPRS DTU USER MANUAL Add:J1-J2,3rd Floor,No.44,GuanRi Road,SoftWare Park,XiaMen,China 1 Zip Code:361008 Contents Chapter 1 Brief Introduction of Product... 3 1.1 General... 3 1.2 Product Features...
200 Range Dialer Installation Manual. Version 1.0
200 Range Dialer Installation Manual Version 1.0 The information contained is supplied without liability for any errors or omissions. No part may be reproduced or used except as authorised by contract
USER MANUAL V5.0 VT300
GPS Vehicle Tracker USER MANUAL V5.0 VT300 Updated on 26/12/2008 Contents 1 Product Overview 3 2 For Your Safety 3 3 VT300 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2 Light and
GSM Gate Control 1000
GSM Gate Control 000 INSTALLATION AND APPLICATION MANUAL for module version v3.3 and higher Manual version:.7 24.06.20 Features: Control of relay outputs with free calls using caller identification Capacity
How to setup a serial Bluetooth adapter Master Guide
How to setup a serial Bluetooth adapter Master Guide Nordfield.com Our serial Bluetooth adapters part UCBT232B and UCBT232EXA can be setup and paired using a Bluetooth management software called BlueSoleil
Business/Home GSM. Alarm System(III) Installation and Users guide
Business/Home GSM Alarm System(III) Installation and Users guide I. General information: GSM 900/1800/1900 bands, can be used all over the world. Full duplex communication with the base. Monitor environment
USER MANUAL V5.0 ST100
GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2
MT-350 SMS. Operation Manual. PORTech Communications Inc.
MT-350 SMS Operation Manual PORTech Communications Inc. Index 1.Hardware Setup...1 2.Software Setup...1 3.Operation Guide...2 4.How to send out a short message...3 5.Report File...6 6.Q & A...6 MT-350
GSM AD05 Slave GSM Auto Dialer- Instruction Manual
GSM AD05 Slave GSM Auto Dialer- Instruction Manual Please read these instructions before you start the installation Features LCD display Programmable 9 x 32 digit phone numbers for each trigger. 10 second
GPS Vehicle and personal location tracker. User manual
GPS Vehicle and personal location tracker User manual 1 Contents 1. Product overview... 2 2. Safety instruction... 3 3. Specification and parameters... 3 4. Getting started... 4 4.1 Hardware and accessories...
Pocket PC Phone Quick Start Guide. Read this guide before operating your Pocket PC Phone.
Pocket PC Phone Quick Start Guide Read this guide before operating your Pocket PC Phone. 1 Feature Maps Front Panel Components 4. 5. 2. 3. 6. 7. 1. 12. 11. 9. 8. 10. 1 Volume. Press to adjust the volume
GSM SMS IR CONTROLLER
Automatically monitoring Air Conditioner by SMS Text! Remotely Control Air Conditioner by SMS Text! Temperature Monitoring by SMS Text! GSM SMS IR CONTROLLER RTU5016 User Manual Ver 1.0 Date Issued: 2012-03-05
TDG134 - GSM Gate Control
USER MANUAL TDG134 TDG134 - GSM Gate Control Technical data GSM / GPRS Module: SIM900 Quad (850/900/1800/1900 MHz) GPRS multi-slot class 10/8 GPRS mobile station class B Output power: Class 4 (2 W @ 850-900
Troubleshooting and Diagnostics
Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem
GSM Elderly Guarder. User Manual. Ver 1.1 Date Issued: 2012-06-20. All rights reserved by Shenzhen Daiya Electronic Technology Co., Ltd.
GSM Elderly Guarder User Manual Ver 1.1 Date Issued: 2012-06-20 All rights reserved by Shenzhen Daiya Electronic Technology Co., Ltd. Website: Page 1 of 17 Shenzhen Daiya Electronic Technology Co., Ltd.
125 8880 telstra.com/ppmbb visit a telstra store or partner GETTING TO KNOW YOUR
FOR MORE INFORMATIoN: 125 8880 telstra.com/ppmbb visit a telstra store or partner GETTING TO KNOW YOUR Telstra PRE-paid 4G wi-fi LET S GET THIS SHOW ON THE ROad WHAT S INSIDE Your Telstra Pre-Paid 4G Wi-Fi
Rev 06 1211. GSM base station. Installation instructions
Rev 06 1211 GSM base station Installation instructions Output string format Baud rate 115200 bps Parity none Data bits 8 Stop bits 1 Flow control none The output string is a modified version of the Sureguard
Mini Amp Gizmo. User s Manual. RJM Music Technology, Inc.
Mini Amp Gizmo User s Manual RJM Music Technology, Inc. Mini Amp Gizmo User s Manual Version 1.1 March 15, 2012 RJM Music Technology, Inc. 2525 Pioneer Ave #1 Vista, CA 92081 E-mail: [email protected]
GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G USB + WI-FI
FOR MORE INFORMATION CALL 125 8880 or FROM A NON-TELSTRA PHONE, CALL 13 2200 AND SAY PRE-PAID VISIT telstra.com/ppmbb VISIT A TELSTRA STORE OR PARTNER GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G USB + WI-FI
Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM
Poseidon 3265 starting guide Poseidon 3265 Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM 1) Connecting Poseidon 3265 1.1) Check DIP switches settings. For installation
Quick Installation Guide LCD GSM ALARM SYSTEM LH http://www.usmartbuy.com
A. Manipulation Specification Quick Installation Guide 1. Arming Arming means all-around guarded when there is no person at home. All detectors are working. Once something triggers any of the detectors,
Business/Home. GSM Alarm system
Business/Home GSM Alarm system Installation and Users guide Profile For a better understanding of this product, please read this user manual thoroughly before using it. I. General information: GSM 900/1800/1900
SMS Alarm. User Manual
SMS Alarm User Manual 1 1. Introduction... 2 2. SMSA1000 Specifications... 3 3. Parts Identifications... 4 4. Packing Contents... 5 5. Battery and SIM Card Installation... 6 5.1 Open the Back Cover...
T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: 2004-07-16 Version 1.0
T-BOXN12R You can make it wireless First steps with T-BOXN12R Date: 2004-07-16 Version 1.0 Content 1. Purpose of this document... 3 2. T-BoxN12R overview... 4 3. First step... 5 3.1. Preparing your workshop
WIRELESS ALARM MONITORING. User Manual V1.2
WIRELESS ALARM MONITORING User Manual V1.2 Please read this user manual fully before attempting installation. Pictures are for indication and illustration purposes only. 1. Accessories Please make sure
User Manual. AS-Interface Programmer
AS-Interface Programmer Notice: RESTRICTIONS THE ZMD AS-INTERFACE PROGRAMMER HARDWARE AND ZMD AS-INTERFACE PROGRAMMER SOFTWARE IS DESIGNED FOR IC EVALUATION, LABORATORY SETUP AND MODULE DEVELOPMENT ONLY.
Business/Home GSM Alarm Systems
Business/Home GSM Alarm Systems Installation and Users guide Profile For a better understanding of this product, please read this user manual thoroughly before using it. - 1 - Ⅰ.General information: 1.
GETTING TO KNOW YOUR PRE-PAID TELSTRA WI-FI 4G
GETTING TO KNOW YOUR PRE-PAID TELSTRA WI-FI 4G LET S GET THIS SHOW ON THE ROAD You must be excited about your brand new Pre-Paid Telstra Wi-Fi 4G. This guide will help you get connected as quickly and
Keep it Simple Timing
Keep it Simple Timing Support... 1 Introduction... 2 Turn On and Go... 3 Start Clock for Orienteering... 3 Pre Start Clock for Orienteering... 3 Real Time / Finish Clock... 3 Timer Clock... 4 Configuring
Using your LED Plus keypad
Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced
MN3310 Evaluation Kit v1 User Guide
1 Evaluation Kit Introduction The MN3310 Evaluation Kit is designed to allow the user to quickly evaluate the Micro Modular Technologies MN3310 GPS receiver module. The evaluation kit can be used in either
Wireless Home Security System Product Manual (Model #80355)
Wireless Home Security System Product Manual (Model #80355) Installation Instructions During set-up, if no key is pressed for 15 seconds it will come out of the setup mode and you will have to start over.
GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G WI-FI
GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G WI-FI LET S GET THIS SHOW ON THE ROAD You must be excited about your brand new Telstra Pre-Paid 3G Wi-Fi. This guide will help you get connected as quickly and
LA-9011 GSM/GPS Tracker User Manual
LA-9011 GSM/GPS Tracker User Manual GSM/GPS Tracker A GSM and GPS Tracking solution to locate and track the whereabouts of your vehicle in real time via the Internet on a computer or Smart phone. The device
VIVA 4G LTE Mini Router. Quick Start Guide
VIVA 4G LTE Mini Router Quick Start Guide Thank you for choosing the VIVA 4G LTE Mini Router (hereinafter referred to as the E57) The supported functions and actual appearance are subject to the product
GSM Voice Auto Dialer& SMS sender JC-999. User Manual
1. Description 1.1 Main features GSM Voice Auto Dialer& SMS sender JC-999 User Manual (1) Large LCD display,integrated keypad, human-friendly programming; (2) Support 12 alarm receiving numbers; (3) Triggering
Configuration Programme
Configuration Programme Handbook Version 4.0 Index Introduction...3 Software Installation...4 The Configuration Programme...6 Options Menu...6 The Configurator... 8 General Settings...8 Telephone book...10
CCTR-811 Vehicle GPS Tracker
CCTR-811 Vehicle GPS Tracker Welcome to use Real Time GPS tracker CCTR-811, This product is with u-blox GPS module and GSM module, it can upload current location to website, display history tracking on
CCTR-810 Real Time Car GPS Tracker
CCTR-810 Real Time Car GPS Tracker Welcome to use this Real Time Vehicle GPS tracker CCTR-810 & tracking system. This product integrates GSM and GPS Module. So it can achieve many functions through our
Get started. Issue 1
Get started Issue 1 2008 Nokia. All rights reserved. Nokia, Nokia Connecting People, Nseries, N85, Navi, and Nokia Care are trademarks or registered trademarks of Nokia Corporation. Other product and company
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE
Thank you for choosing HUAWEI Mobile WiFi
Thank you for choosing HUAWEI Mobile WiFi Supported functions and actual appearance depend on the specific models you purchased. The illustrations are provided for your reference only. For details about
FOR MORE INFORMATION. 125 8880 or from a non-telstra phone 13 2200 and say pre-paid telstra.com/ppmbb visit a telstra store or partner
FOR MORE INFORMATION 125 8880 or from a non-telstra phone 13 2200 and say pre-paid telstra.com/ppmbb visit a telstra store or partner getting to know your telstra pre-paid 4G WI-FI (760S) LET S GET THIS
Connecting your Victron product to a computer with VE Configure
Connecting your Victron product to a computer with VE Configure www.victronenergy.com VE configure II is a program used to configure settings/options on a Multi or Quattro. It is necessary to know several
Users Manual of GSM Home Alarm System with Photo-taken
GSM-IV REMOTE CAMERA MANNAL The Excellent GSM + Camera alarm system bases on the GSM network, integrates the communication technology, can automatic screen a photo with the intruder or burglar, and send
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
Car Alarm Tracker Manual-20150814
CCTR-922 Car Alarm Tracker Manual-20150814 Welcome to use this GSM car alarm with tracker function CCTR-922. this product use 2G GSM network (LBS locate) to locate the car, it has many new and unique functions,
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
Version:G300 V2.0 11.04. Business/Home GSM Alarm System. Installation and Users' Guide. ( 99 wireless zones)
Version:G300 V2.0 11.04 Business/Home GSM Alarm System Installation and Users' Guide ( 99 wireless zones) Brief Introduction: GSM 850/900/1800/1900 bands, can be used in most parts of the world Full duplex
ENTBUS PLUS SOFTWARE FOR ENERGY MONITORING AND RECORDING INSTALLATION AND OPERATING MANUAL
ENTBUS PLUS SOFTWARE FOR ENERGY MONITORING AND RECORDING INSTALLATION AND OPERATING MANUAL Foreword Entbus services manage the collection of information and storing this information in the database. Services
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)
CN2HK LIMITED Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003) User Manual Please read this manual before operating this product. After you finish reading this manual,
CM HOST CM CardTransporter Fuel Communication and Management Software 10.10.06 Software version up to 3.1
CM HOST CM CardTransporter Fuel Communication and Management Software 10.10.06 Software version up to 3.1 CM Host Manual For CardMaster Fuel Control www.cardlockvending.com customers call 888-487-5040
GSM Elderly Guarder User Manual Ver 1.0 X-TRON
GSM Elderly Guarder User Manual Ver 1.0 X-TRON Page 1 of 18 X-TRON Page 1 of 18 Ver 1.0 File No.:XT-EASX001 Table of Contents 1. Brief introduction -------------------------------------------------------------------3
CCTR-800 Portable Real Time GPS Tracker
CCTR-800 Portable Real Time GPS Tracker Welcome to use this Real Time GPS tracker CCTR-800, This product is with GPS module and GSM module, It has many new and unique functions, such as real time uploading
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
User guide. T250i. This is the Internet version of the User's guide. Print only for private use.
User guide T250i Congratulations on your purchase of the Sony Ericsson T250i. For additional phone content, go to www.sonyericsson.com/fun. Register now to get free online storage and special offers at
To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:
PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,
MN1010 Evaluation Kit v3 User Guide
1 Evaluation Kit Introduction The MN1010 Evaluation Kit is designed to allow the user to quickly evaluate the Micro Modular Technologies MN1010 GPS receiver module. This kit can be used in either a laboratory
GSM Home Alarm System User Manual. http://www.usmartbuy.com
GSM Home Alarm System User Manual http://www.usmartbuy.com 1 1. Factory default Normally, all sensors in the big box have been coded (learnt) to the control host Operation Password: 0000 Long-Distance
Thank you for choosing Huwei E589 4G Mobile WiFi
Thank you for choosing Huwei E589 4G Mobile WiFi This guide briefly describes the functions of your Huawei E589 4G Mobile WiFi. For more details, see help on the web management page. See Accessing the
STIM202 Evaluation Kit
Table of contents: 1 FEATURES... 2 2 GENERAL DESCRIPTIONS AND SYSTEM CONTENTS... 2 3 SYSTEM REQUIREMENTS... 2 4 GETTING STARTED... 3 4.1 INSTALLATION OF NI-SERIAL CABLE ASSEMBLY DRIVER... 3 4.2 INSTALLATION
PDA Software Manual For the Windows CE and Mobile Operating Systems
PDA Software Manual For the Windows CE and Mobile Operating Systems Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560,
GPS/GSM Personal Tracking Device
GPS/GSM Personal Tracking Device User Manual INDEX Usage Packing list Before using Add/Delete/Check Preset Phone Number Change / Check Password Set langue Set SMS locate mode after calling Send a SMS trigger
