TDG134 - GSM Gate Control
|
|
|
- Esther Leonard
- 9 years ago
- Views:
Transcription
1 USER MANUAL TDG134 TDG134 - GSM Gate Control Technical data GSM / GPRS Module: SIM900 Quad (850/900/1800/1900 MHz) GPRS multi-slot class 10/8 GPRS mobile station class B Output power: Class 4 ( MHz) Class 1 ( MHz) GSM external stylus antenna Power supply: 9 to 32 Vdc stabilized (or with Li-Ion battery 800 1,000 ma/h) Idle current: 50 ma idle, peak up to 1 A Relay output to control low tension loads, SELV type (< 60 Vdc) Max current relay contacts: 10 A Master users: 8 Gate control users: 200 Free of charge gate control call Dimensions: 103x67x28 (LxWxH) mm Weight approx.: 76 grams Operating temperature: -10 C +55 C (14 F F) Complies with EN (2006), EN V.1.3.1, EN V
2 TDG134 USER MANUAL TABLE OF CONTENTS 1. Important information Safety instructions General information Operating conditions Proper use Introduction Connectors and LEDs Installing the USB Start-up Configuration Configuration SMS Table of command and configuration SMS Managing the device through a computer Troubleshooting
3 USER MANUAL TDG Important information Please, carefully read the information in this manual before attempting to operate the device in order to protect yourself and use the equipment properly. This device shall be exclusively utilized for its intended use. In no event shall the company Futura Elettronica, or its dealers, be held responsible for any damage, either extraordinary, incidental or indirect of any nature (financial, physical, etc.), arising from the possession, use or failure of this product. In case of changes to the device, tampering, or non-compliance with the instructions in this manual the warranty will be null and void. The device contains highly integrated components that can be damaged by electrostatic discharge. Therefore, do not touch any metal part (tracks, component terminals, etc.) with your hands. Only handle the device by the edges in order to avoid touching the components on the board. Notice The user who makes the module operational by adding further components or by putting it into a housing is seen as a manufacturer and is obliged to hand out all the necessary technical documentation as well as place his name and address on the device. Products made with this equipment have to be considered as industrial products from the safety perspective. The phone costs related to sending SMS generated by the device are charged on the SIM in the device. 2. Safety instructions In accordance with the current regulations on safety, whenever using a device under tension all necessary precautions shall be taken. The device must always be installed in absence of tension. The device must be placed into a suitable housing before use. During the installation, the device must not be connected to the power source or to other devices. Before handling the device or opening the container where it has been placed, unplug the power connector and make sure the circuit is not live. Before working with any kind of tool on the device make sure it is disconnected from the power supply and that components that store energy (capacitors) are discharged. All cables connected to the device, particularly the power supply ones, have to be checked regularly for fractures or damage of the isolation shield. If cables are visibly damaged, the device has to be switched off immediately until they have been replaced. Strictly comply with the technical specifications of components or modules used with this device. If the information contained herein and/or the information on the components or modules used with the device are not clear enough, please contact a qualified technician. 3
4 TDG134 USER MANUAL Before starting the device, carefully check whether it is suitable for the intended field of application. In case of doubt, please contact a qualified technician or the Manufacturer / Dealer. The Manufacturer / Dealer cannot be held responsible for improper handling or wrong connections, therefore it cannot be held responsible for any damage that may result. Devices that operate with <35 Volts must be connected by a qualified technician. Before starting the device check there is no current leakage in the housing. If measurements are to be made with an open housing, an isolating-transformer has to be integrated for safety reasons. Alternatively, tension can be supplied by a power supply that complies with all safety regulations (limitations in current and tension). All wiring work has to be done in a tension free state. 3. General information For EU residents Environmental information related to this product This symbol on the device or package indicates it is forbidden to dispose of the product in the environment at the end of its lifecycle as it could be harmful for the environment itself. Do not dispose of the product (or batteries, if used) as unsorted waste. For more information about the recycling of this product, please contact the city hall, your local waste disposal service, or the shop where it was purchased. 4. Operating conditions Warning: before making connections to the device, carefully verify that the supply tension and the tension applied to the relay contacts correspond to those described in this manual! Important information: The device must be installed in compliance with the current safety standards. Supply the remote TDG134 only with stabilized DC tension between 9 and 32 V, to be applied to the power plug PWR (see Picture 1) keeping in mind the polarity (center positive). Use a safety current-limited power supply providing current of at least 500 ma, able to cope with absorption peaks of 1 A. The power cable must not exceed 3 meters. 4
5 USER MANUAL TDG134 The relay outputs in the device can only be used to control low tension loads SELV type (<60 Vdc). The tension applied to the contacts of each relay must not exceed 60 Vdc. The switching current on the relays must not exceed 10 A (*). The device can work in any position. Check that the section of the cables used is enough. The operating temperature of the device ranges between -10 C and +55 C (14 F F). The container used to house the device must have adequate ventilation holes! If moisture condensation occurs, wait for at least 2 hours before starting the equipment. Keep the device away from flower vases, sinks, water pipes, etc. Protect the device from moisture, spray water and heat. The device is meant for operation in clean and dry rooms. Do not expose the device to heavy vibrations. Do not use the device in presence of flammable gases, vapors or dust. The device can only be repaired by a qualified technician. When repairing the unit, original parts must be used. The use of differing spare parts can cause serious material loss or personal injury. *the tracks connecting the relay contacts to the terminal are sized considering a load activation which absorbs 10 A for short periods of time. 5. Proper use This device is designed for the remote activation, via the GSM network, of electric gates (together with the gate electric system) or any other electric unit. A different use is not allowed. 5
6 TDG134 USER MANUAL 6. Introduction The TDG134 is a GSM control system easy to install and simple to use. With this device a relay can be managed remotely (in bistable or monostable mode) through a call made to the phone number of the SIM Card in the device or by means of special SMS (with a password), sent from any mobile. It is possible to store up to 8 telephone numbers enabled to change the settings of the system the device sends reply SMS to. In order to quickly set the module, it is also possible to use a computer (with the special TDG Configurator software) connected via USB FT782M (optional) installed on the card. The device, that can be controlled by up to 200 enabled phone numbers, needs an active SIM Card from any GSM network provider using GSM 900/1800 MHz networks. When using a prepaid SIM Card always check the available credit so that the device can send the reply message to any possible command (if the function has been enabled). Typical fields of application include gate opening, control of power loads, switching on and off alarm systems, etc. 7. Connectors and LEDs As shown in figure 1, the TDG134 remote control has a 3-pin terminal to connect contacts NC, NO and C of its relay. Connect the supply tension (between 9 and 32Vdc) of the device to the outlet marked PWR (center positive). Via USB (optional) directly installed on the card you can connect a computer; with the special TDG Configurator software it is possible to make all programming and function setting or change the list of authorized users. Functions of the LEDs: LD1 = on - relay excited; off - relay unexcited LD3 = in stand alone mode: flashing - SMS reception. Computer mode: continuously on - computer mode; flashing- indicates the passage of the Monostable Activation time. LD4 = flashing call reception LD5 = on - call reception; flashing at 1 Hz frequency - network research; brief flashing every 2 seconds hooked in the network. LD3 and LD4 also report a CONFIGURATION CALL on hold (both LEDs turn on alternatively) after start-up and without phone numbers stored in the list. 6
7 USER MANUAL TDG134 Power supply connector PWR (center positive) USB interface (optional) SIM card slot SMA female connector for GSM antenna Picture 1 LD1 LD3 LD4 LD5 C NO NC OUT 8. Installing the USB A special USB interface (code FT782M), available separately, must be installed on the remote control card as shown in the picture alongside, the mini USB connector must be upwards. 9. Start-up You must fi rst obtain a valid SIM Card from a GSM network provider. Use a common mobile phone to disable the SIM Card PIN. To do so check the manual of the mobile. If the SIM Card PIN is not disabled, the device cannot work as it cannot connect to the GSM network. Before feeding the TDG134, please insert the SIM Card into the SIM Card holder (mind the orientation) making sure it is correctly blocked, then connect the antenna cable to the connector. Now connect the power supply. 7
8 TDG134 USER MANUAL 10. Configuration The device can be set as follows: - EASY SETUP (Configuration through call) - PROFESSIONAL SETUP (Configuration through SMS) - Computer SETUP (Configuration through PC connection: it needs a USB interface, code FT782M available separately) 1) EASY SETUP (Configuration through call made on start-up) When the device is supplied with power, LD5 will immediately flash at 1Hz frequency. The TDG134 will try to connect to the GSM network; when connected, LD5 will briefly flash every 2 seconds or so. After the system initialization (which may take several seconds), the device alternately illuminates the yellow LEDs LD3 and LD4 to indicate the configuration call on hold, which should take place within 3 minutes. If during this time the unit receives a call, it stores the caller s number (to which reply SMS will be sent) in the first memory location, it turns the two LEDs off and becomes operative; otherwise, at the end of the interval, it switches off the yellow LEDs and waits for the configuration SMS ( PROFESSIONAL SETUP mode). With the same phone used to make the first setup call, it is also possible to switch the relay status. This mode allows for simple commands without sending SMS or using a computer. 2) PROFESSIONAL SETUP (Configuration through SMS executable at any time) This mode takes full advantage of the device with operations as output switch, output status query, inclusion of additional phone numbers to activate the relay, inclusion of numbers for door opening function, reception of reply messages, change of output signals timing and, in general, set the TDG134 with all parameters via simple SMS. A full reset to restore the default settings can also be made via SMS. The syntax for all available commands can be found in Section 11 (Configuration SMS). 3) Computer SETUP (Configuration through PC connection) This mode easily allows you to setup the TDG134 -with no additional cost- through a computer (with a special software) connected via USB code FT782M (optional). Chapter 13 provides all the necessary information to make the best use of this configuration mode. Configuration through call Turn on the device, wait till the yellow LEDs LD3 and LD4 start to flash alternately; then, with the mobile used to control the TDG134 call the phone number corresponding to the SIM Card in the remote control. The device will reject the call and store the caller number in the first memory location. LD3 and LD4 will flash rapidly to indicate the operation. Check that the mobile used for the configuration has an active ID, i.e. the hidden call or private call has not been enabled. To return to the standard configuration with active ID, please refer to the mobile instruction s manual. To check your own mobile configuration simply call another mobile: The caller ID is active if it displays the number 8
9 USER MANUAL TDG134 or name of the calling mobile. NOTE: Yellow LEDs LD3 and LD4 lighten up alternately until the TDG133 is set up with a call within the first three minutes of start-up. If time is up and no configuration has been made, the TDG133 turns off the two LEDs and waits for the configuration SMS. The EASY SETUP mode can be restored by disconnecting and reconnecting the power supply: you will have three minutes to set up the device. 11. Configuration SMS Commands and settings can be sent from any mobile via SMS as long as the message includes the password. To speed up certain commands, it is possible for the device to store 8 numbers enabled to send commands without the password in the device. The numbers in this list are the same to which (if enabled) a few rings or alarm messages will be sent. However, there is a series of sensitive functions, that no matter who sends the SMS, require a password: in particular, functions that add or remove other numbers from the list, that change the current password, or request the list of approved numbers. As a result of a command or query, the device replies via an execution confirmation SMS or a SMS with information about the settings. Please note that all commands that do not require a password are effective only if they come from a recognized phone, that is a phone which number is in the list of those stored in the remote; an outsider needs a password. The remote accepts multiple SMS, that is SMS with more than one command regarding one or more phone numbers; commands must be separated by a comma. Here we present and describe all commands that can be sent to the device via SMS. Note: Every command must be written without spaces. - Command PWDxxxxx;pwd changes the password; xxxxx is the new password (numeric, five digits); pwd is the current password (the default password is 12345). Example: as the new password and as the current password PWD54321;12345 Note: The password is required. - Command NUMx+39nnnnnnnnnnn;pwd stores a phone number (up to 8 numbers, 19 digits each) in the device; x is its position in the list; nnnnnnnnnn is the phone number with country code (+39 for Italy); pwd is the current password. Example: How to enter number in the 8th position NUM ;12345 Note: The password is required. 9
10 TDG134 USER MANUAL - Command NUMx;pwd removes a phone number from the list; x is its position in the list; pwd is the current password. Example: How to remove from the stored list the 4th telephone number NUM4;12345 Note: The password is required. - Command NUM?;pwd requests the list of phone numbers currently stored in the device; pwd is the current password. Example: NUM?;12345 Note: The password is required. - Command RES;pwd resets the initial settings (default) of the system (stored phone numbers are not deleted); pwd is the current password. Example: RES;12345 Note: The password is required. The operation mode, the timing, and the status requests of the output relay can be managed by SMS: - Command OUT:ON activates the output relay in bistable mode; Example: How to activate output relay OUT:ON - Command OUT:OFF disables the output relay in bistable mode. Example: How to disable output relay OUT:OFF - Command OUT:ss inverts the condition of the output relay for the desired time; ss is a period of time between 1 and 59 seconds. Example: How to disable output relay (if already active) or how to activate it (if not active) for 10 seconds OUT:10 - Command OUT? requests the output relays status of the remote. Example: OUT? - In case of black-out, command RIPx stores the relay status and restores it when power is back on; x has a value of 1 to enable restoring, 0 to disable it. The default value is 1. Example: How to enable the relay status recovery on start-up RIP1 Example: How to disable the relay status recovery on start-up 10
11 USER MANUAL TDG134 RIP0 - Command RIP? requests the current setting for relay status recovery. Example: RIP? The following describes the commands of the functions for the door control mode: - Command MAC+39xxxxxxxxxx;pwd stores the phone numbers that control the gate opener function only; xxxxxxxxxxx is the phone number you want to store in the list (200 numbers max.) with international code (+39 for Italy); pwd is the current password. Note: The password is required. Example: How to store number , being the password MAC ;12345 Note 1: For the gate control function there is no specific storage position. Each number is saved in the first available position; it follows that, in order to delete a number it is necessary to type the number itself in the relevant command, not its position. - Command DAC+39xxxxxxxxxxxx;pwd deletes a phone number from the gate control list; xxxxxxxxxxx is the phone number you want to delete with its international code (+39 for Italy); pwd is the current password. Note: The password is required. Example: How to delete number being the password DAC ; Command DAC;pwd deletes all numbers in the gate control list; pwd is the current password. Note: The password is required. - Command TAC:ss defines how the relay should be activated when there is an incoming call from one of the 200 numbers or one of the 8 numbers in the list; ss is the time (in seconds) during which the relay should remain excited. The default value is 5 seconds. Example: How to set a gate control activation time of 25 seconds TAC:25 Example: Gate control activation bistable mode setting TAC:00 Note: The time value can be set between 00 and 59 seconds. Bistable activation is obtained by setting 00. The relay clicks and remains excited until the arrival of a new call from the same number in the list that has caused the activation, or from another number enabled for the gate control. As already mentioned at the beginning of Chapter 11, the system accepts messages with multiple commands separated by a comma helping the user save time and mon- 11
12 TDG134 USER MANUAL ey. There follows that the system replies to certain commands with more than one SMS. This can be avoided by means of a command placed at the beginning of the SMS sent to the TDG Command RISP at the beginning of a multiple message disables all reply messages. Example: How to disable the answer message related to the sent commands RISP,OUT:ON,RIP1 12. Table of command and configuration SMS FUNCTION SMS COMMAND DEFAULT VALUE PWD REQUI- RED PASSWORD REPLACEMENT PWDxxxxx; pwd YES STORE NUMBERS (max. 8 numbers) per number); NUMx ; pwd - YES DELETE A NUMBER NUMx; pwd - YES CHECK STORED NUMBERS NUM?; pwd - YES FULL RESET OF ALL PARAMETERS RES; pwd - YES RELAY ACTIVATION IN BISTABLE MODE OUT:ON - - RELAY DEACTIVATION IN BISTABLE MODE OUT:OFF - - CHANGE OF MONOSTABLE RELAY STATE (01-59 seconds) OUT:ss - - RELAY STATUS REQUEST OUT? - - RELAY RESET, x IS 1 TO OBTAIN RESET, 0 TO HAVE THE RELAYS DISABLED RIPx 1 - RESET QUERY RIP? 1 - STORE NUMBER FOR GATE CONTROL FUNCTION (max 200) MAC+39xxxxxx; pwd - YES DELETE NUMBER FOR GATE CONTROL STORAGE DAC+39xxxxxx; pwd - YES TOTAL DELETION OF GATE CONTROL LIST (except for the first 8 numbers) GATE CONTROL DEACTIVATION TIME ss 00 (bistable) 59 DAC; pwd - YES TAC:ss 5 - DISABLE ANSWER FOR THAT MULTIPLE MESSAGE RISP,
13 USER MANUAL TDG Managing the device through a computer By means of a computer with a specific software and USB interface code FT82M (optional) installed directly on the board, it is possible to manage all programming and function settings as well as change the list of enabled users. This speeds up the initial settings and saves on the cost of SMS. After starting the software, verify that a communication speed of 9600 Baud (8,N,1) is set. Installing and using the software The software can be downloaded at from the page of the TDG134. In order to use the management software it is first necessary to install it. Launch the Setup files and follow the installation instructions as they appear. Once this is done, start the program. After this, the window TDG Configurator appears on the screen, through this window it is possible to modify all the settings of the device, add users, change the password, etc. It is an intuitive program and the graphic interface simplifies this procedure. So as to use the available commands, supply and connect the TDG134 to the computer, then select the communication port COM (top left) created. If need be, with the Update button you can update the list related to the available ports in the computer. Afterwards, press Connect to activate the connection and wait for the screen to update with all the data on the connected module. From now on, the TDG134 can be managed from you computer (PC mode is shown by LD3 on). 13
14 TDG134 USER MANUAL If the device was connected to the computer before the storage of the first master number, the message Waiting for Call for Master Number Storage will appear on the log window (down). In order to continue with the setting, make the call so as to store the number. The execution will be confirmed with a message on the log window. In the Information tab you can find the IMEI and the firmware version of the connected device. In order to modify the access password stored on the device, type in the fields Old and New the desired password and press Run. To access the system and make all possible settings, please type the current password in the field System password, then press Confirm. If the device does not reply to the commands sent from the computer, make sure the password stored in the PC is the same as the one specified in the management program. 14
15 USER MANUAL TDG134 Management of phone numbers enabled for the control of the device and of those related to the gate control function is done through the folder Telephone Numbers. It is possible to store or delete the enabled numbers and to request the full list (visible on the right of the window) of those numbers in the device. Every selected operation ( Store, Delete or Request Full List ) must be confirmed by pressing Run. 15
16 TDG134 USER MANUAL The tab Outputs is used to enable or disable the function Restore Relay Status in absence of tension, directly manage the relay, and set its activation time in gate control mode. Pressing Activate Extended Log it is possible to visualize, in a specific window, all data in transit through the communication port. 16
17 USER MANUAL TDG134 The software version can be seen pressing? on the menu bar. Important: Management via SMS is disabled when the TDG134 is connected to the computer. 14. Troubleshooting The following table presents the possible solutions to some problems that may arise: Problem Possible reason Solution Green LED LD5 is off Green LED LD5 flashes cyclically at 1 Hz frequency The device does not send a reply to the configuration SMS During the first start-up LEDs LD1 and LD3 do not lighten alternatively The device does not react to the call from an enabled number The device cannot engage in the GSM network No supply tension or inverted polarity No GSM network available or signal intensity not enough The answer to the message with command RISP is disabled or there is no credit on the SIM card. The device has already been started The mobile used for the call has a hidden ID The PIN on the SIM Card has not been disabled Controllare il cavo di alimentazione Change the position of the external GSM antenna Do not use the RISP command in the SMS, or recharge the SIM Card. Completely reset the device using the RES command. Enable the ID on outcoming calls Disable the PIN request from the SIM Card The information in this manual is subject to change without notice. Technical Assistance In case of technical problems or questions concerning the TDG134, a hotline is available: Mon and Wed: 2 pm - 6 pm CET (Central Europe Time) Technical assistance
18 TDG134 USER MANUAL 18
19 USER MANUAL TDG134 19
20 TDG134 USER MANUAL Complies with all applicable european directives. Produced and distributed by: FUTURA ELETTRONICA SRL Via Adige, Gallarate (VA) Tel Fax web site: technical Information: Relase: 29/10/2010 V.I V.F
GSM Alarm System User Manual
GSM Alarm System User Manual For a better understanding of this product, please read this user manual thoroughly before using it. Quick Guider After getting this alarm system, you need to do the following
GSM Desktop phone DPH101. User manual v1.00
GSM Desktop phone DPH101 User manual v1.00 LEGAL NOTICE Copyright 2011 TELTONIKA Ltd. All rights reserved. Reproduction, transfer, distribution or storage of part or all of the contents in this document
19 LED Tube Controller ORDERCODE 41003
19 LED Tube Controller ORDERCODE 41003 Congratulations! You have bought a great, innovative product from Showtec. The Showtec 19 LED Tube Controller brings excitement to any venue. Whether you want simple
CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual
CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CGWTS-M001A Version 1, Release 1, December 2004 NOTICE
GSM ATT Modules Simply effective remote control
GSM ATT Modules Simply effective remote control To control electrical loads via mobile phone The benefits Remote management of electrical devices is an increasingly widespread requirement in residential
EPSON USB/Parallel Adapter User s Guide
EPSON USB/Parallel Adapter User s Guide EPSON Stylus COLOR 440 EPSON Stylus COLOR 800 EPSON Stylus COLOR 600 EPSON Stylus COLOR 850 EPSON Stylus COLOR 640 EPSON Stylus COLOR 1520 EPSON Stylus Photo EX
Model 70A00-1. GSM Cellular Communications Center
Home Automation, Inc. Model 70A00-1 GSM Cellular Communications Center Operation Manual Document Number 70I00-1 Rev A August, 2009 Contents Description... 1 Use with security systems...1 Everyday use...2
B890 4G LTE Smart Hub Getting Started Guide
B890 4G LTE Smart Hub Getting Started Guide HUAWEI TECHNOLOGIES CO., LTD. Thank You for Purchasing the B890 4G LTE Smart Hub! Before You Begin What s in the Box : 1. B890 4G LTE Smart Hub 2. Power adapter
Intelligent GSM Auto-dial Alarm System User s Manual
Intelligent GSM Auto-dial Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. [Function Instruction] [Control Panel Introduction]
AXIS T81B22 DC 30W Midspan
INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial
Configuring the Siemens TC35 modems for use with the MI2292
Configuring the Siemens TC35 modems for use with the MI2292 The following instruction describe how to set up GSM communication between an MI2292 Power Quality Analyser Plus and a computer 1. Equipment
The GD-04K universal GSM communicator and controller
The GD-04K universal GSM communicator and controller The GD-04K is a universal GSM communicator. It controls and / or reports status of different appliances remotely. Control can be performed by SMS instructions
NFC Communication Tray Model: HHX-IT3-Z
INSTRUCTION MANUAL NFC Communication Tray Model: HHX-IT3-Z ENGLISH CONTENTS Introduction...3 Important safety information...4 Know your unit...6 Transferring data to the PC...7 Care and maintenance...8
2013 VTech Printed in China 91-009656-000 US
Rechargeable Power Pack User s Manual 2013 VTech Printed in China 91-009656-000 US INTRODUCTION The Rechargeable Power Pack makes it easier than ever to keep the InnoTab 3 or InnoTab 3S charged and ready
User Guide for the Wireless Headset (HS-11W) 9235346 Issue 1
User Guide for the Wireless Headset (HS-11W) 9235346 Issue 1 DECLARATION OF CONFORMITY We, NOKIA CORPORATION declare under our sole responsibility that the product HS-11W is in conformity with the provisions
GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G USB + WI-FI
FOR MORE INFORMATION CALL 125 8880 or FROM A NON-TELSTRA PHONE, CALL 13 2200 AND SAY PRE-PAID VISIT telstra.com/ppmbb VISIT A TELSTRA STORE OR PARTNER GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G USB + WI-FI
HWg-STE HWg-STE PoE MANUAL
HWg-STE HWg-STE PoE MANUAL www.hw-group.com Page 2 HWg-STE connectors LED indicators Green: Power & Mode Yellow: Link & Activity SENSORS S1 and S2 ports for connecting temperature or humidity sensors.
GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G WI-FI
GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G WI-FI LET S GET THIS SHOW ON THE ROAD You must be excited about your brand new Telstra Pre-Paid 3G Wi-Fi. This guide will help you get connected as quickly and
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
How to connect your D200 using Bluetooth. How to connect your D200 using GPRS (SIM Card)
D200 En User Guide Content 3 Introduction 3 Scope 3 Related Documentation 4 Internet Connectivity 4 Using D200 with Mobile Phone 5 Using D200 with wireless (Wi-Fi) router 6 Using D200 with GPRS (requires
GSM remote controller v7.0 / v7.0 PRO. Operating Instructions
GSM remote controller v7.0 / v7.0 PRO Operating Instructions Table of contents 1 Delivery content...3 1.1 optional accessories...3 2 Safety...4 3 Intended use...4 4 responsibility and liability...5 5 Malfunctions...5
USER MANUAL V5.0 VT300
GPS Vehicle Tracker USER MANUAL V5.0 VT300 Updated on 26/12/2008 Contents 1 Product Overview 3 2 For Your Safety 3 3 VT300 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2 Light and
Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO
GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module
FOR MORE INFORMATION. 125 8880 or from a non-telstra phone 13 2200 and say pre-paid telstra.com/ppmbb visit a telstra store or partner
FOR MORE INFORMATION 125 8880 or from a non-telstra phone 13 2200 and say pre-paid telstra.com/ppmbb visit a telstra store or partner getting to know your telstra pre-paid 4G WI-FI (760S) LET S GET THIS
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL
Rev. D PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL 10 BORIGHT AVENUE, KENILWORTH NEW JERSEY 07033 TELEPHONE: 800-524-0273 FAX: 908-686-9317 TABLE OF CONTENTS Page
Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7
Register online today for a chance to win a FREE Tripp Lite product! www.tripplite.com/warranty Owner s Manual Internet Office & BC Personal UPS Systems Not suitable for mobile applications. Important
Rev 06 1211. GSM base station. Installation instructions
Rev 06 1211 GSM base station Installation instructions Output string format Baud rate 115200 bps Parity none Data bits 8 Stop bits 1 Flow control none The output string is a modified version of the Sureguard
PUSH BUTTON START INSTALLATION MANUAL
PUSH BUTTON START INSTALLATION MANUAL ALTHOUGH THIS PRODUCT HAS BEEN THOROUGHLY TESTED KPIERSON TECHNOLOGIES ASSUMES NO RESPONSIBILITY FOR ANY DAMAGE THAT MAY RESULT BY THE INSTALLATION OF THIS PRODUCT.
INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.
SA-2000-II HARDWARE MANUAL Access Technologies International, Inc. 1 Table of Contents 1. Introduction 3 2. Features 3 3. Specification 4 4. Identifying Supplied Parts 4 5. Panel Description 5 6. Connection
GETTING TO KNOW YOUR PRE-PAID TELSTRA WI-FI 4G
GETTING TO KNOW YOUR PRE-PAID TELSTRA WI-FI 4G LET S GET THIS SHOW ON THE ROAD You must be excited about your brand new Pre-Paid Telstra Wi-Fi 4G. This guide will help you get connected as quickly and
Instruction Guide. 4 Port Laptop-Sized USB 2.0 Mini Hub ST4200MINI. The Professionals Source For Hard-to-Find Computer Parts
USB 2.0 HUB 4 Port Laptop-Sized USB 2.0 Mini Hub ST4200MINI Instruction Guide * Actual product may vary from photo The Professionals Source For Hard-to-Find Computer Parts FCC COMPLIANCE STATEMENT This
GETTING TO KNOW YOUR 4G USB
GETTING TO KNOW YOUR Telstra Pre-paid 4G USB LET S GET THIS SHOW ON THE ROAD WHAT S INSIDE Your Telstra Pre-Paid 4G USB has been tested to the highest standards to deliver you the best possible coverage
EWR2 WIRELESS SIGNAL REPEATER
SIGNAL REPEATER User manual v1.2 Compatible with: ESIM364 v02.07.11 and up EPIR3 v01.01.00 and up EWP1 v16 and up EKB3W v8 and up EW1 v33 and up EWS1 v16 and up EWD1 v19 and up EWK1 v19 and up EWS2 v15
EST-64 GSM Remote Control Device User Manual E E S S T T A A T T E E S S W W I I N N G G
EST-64 GSM Remote Controll Deviice User Manual EESSTTAATTEE SSWIINNGG Electronic KIT to convert your gate into a GSM gate EST-64 GSM Remote Control Device Diagram 2 1. INTRODUCTION EST-64 GSM Remote Control
VIVA 4G LTE Mini Router. Quick Start Guide
VIVA 4G LTE Mini Router Quick Start Guide Thank you for choosing the VIVA 4G LTE Mini Router (hereinafter referred to as the E57) The supported functions and actual appearance are subject to the product
GSMPBX version 1.3 Datasheet
GSMPBX version.3 Datasheet Document Rev.:.3 Revision Date: 23.03.203 (preliminary data) Figure - GSMPBX Introduction The GSMPBX is designed to commute phone calls between a cellular network (GSM) and the
Android Dongle. User Manual TL869
Android Dongle User Manual TL869 2 User Manual Android TV Dongle Before using the product, please read this manual thoroughly. The specifications and software in this manual are subject to change without
GSM Remote control. Version W-BUS v9.x. Operating manual
GSM Remote control Version W-BUS v9.x Operating manual Antenna Status LED Release SMA Connection SIM card Front view Release PIN 1 PIN 8 Back view Table of contents 1 Scope of delivery...4 2 Safety instructions...5
STATUS POWER MONITOR ALARM SOS DISARM
STATUS POWER MONITOR ALARM SOS DISARM I. Features II. Preparation before use III. Host 1.LED status explanation 2. Host panel IV. System Settings 1. Coding of wireless sensors 2. Exit coding 3. Settings
Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10
Business Audio System: Music & Messaging MP3 Player by Grace Digital Audio User Guide Model No. GDI-USBM10 User Guide Contents Introduction 2 Safety & General Use Information 2 Features 3 Set Up & Operation
Important Safety Instructions
PR-D7 GB Revision 1 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean
INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM
INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM Revised: August 28, 2014 PRODUCT REFERENCE MOUNTING ACCESSORIES PIR / MOTION DETECTION UNIT MAIN UNIT POWER ADAPTER MOUNTING ACCESSORIES
INDEX. Trademarks All name and product s trademarks mentioned below are the property of their respective companies.
USB2.0 EASY IDE ADAPTER INDEX Trademarks ---------------------------------------------------------------------------- Introduction ---------------------------------------------------------------------------
Portable Bluetooth Speaker. Quick Start Guide. Model: BTS201
Portable Bluetooth Speaker Quick Start Guide Model: BTS201 Disclaimer All the information, design and specifications contained in this manual were correct at the time of publication. However, as the product
New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.
New GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Chapter 1. Features Chapter 2. Alarm Host Introduction Chapter
Contents Contents Contents Overview Charging your headset Wearing the headset Powering on the headset Connecting your headset for dictation
1 Contents Contents Contents 2 Overview 3 Charging your headset 4 Wearing the headset 4 Powering on the headset 4 Connecting your headset for dictation 5 The adapter 5 Adjusting your computer's audio settings
Nokia USB Modem. Issue 1.1
Nokia USB Modem Issue 1.1 2 Contents About your USB modem 3 Get started 3 Parts 3 Insert the SIM card 4 Insert a memory card 4 Install the connection manager 6 Uninstall from your computer 6 Internet connection
GSM Gate Opener GSM Remote Switch RTU5015 User Manual
GSM Gate, Barrier, Shutter, Garage Door and Door opener Open gate or garage door with a FREE call from your mobile phone! Remote switching machines with a FREE call from your mobile phone! GSM Gate Opener
Troubleshooting and Diagnostics
Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem
MANUAL GSM CONTROLLER
MANUAL GSM CONTROLLER CallFree2 CallFree 3G 2 outputs, 3 inputs ` Please read these instructions completely before use GSM CallFree 1/17 Revision V1.3C, Aug 2015 TABLE OF CONTENTS 1. SAFETY PRECAUTIONS...
Operating Instructions
Operating Instructions Kühn Controls AG, Gräfenhäuser Str. 14, D-75305 Neuenbürg, Germany Tel. +49 (0)7082-94 00 00 www.kuehn-controls.de [email protected] Fax +49 (0)7082-94 00 01 Content 1. SMS
ZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
WPR400 Wireless Portable Reader
P516-098 WPR400 Wireless Portable Reader User guide Para el idioma español, navegue hacia www.schlage.com/support. Pour la portion française, veuillez consulter le site www.schlage.com/support. Contents
T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: 2004-07-16 Version 1.0
T-BOXN12R You can make it wireless First steps with T-BOXN12R Date: 2004-07-16 Version 1.0 Content 1. Purpose of this document... 3 2. T-BoxN12R overview... 4 3. First step... 5 3.1. Preparing your workshop
Rousseau 10. User Guide
Rousseau 10 User Guide Base station overview ➀ LED signals White, permanent light: - Base station ready, you can register a handset Slow flashing white light: - Paging call in progress - Active call (you
Getting started with
PART NO. CMA113 MADE IN CHINA 1. Measuring CAT II 2. Max. voltage 250V ~ 3. Max. current 71 Amp Getting started with Electricity consumption monitoring single phase for homes and some smaller light commercial
Point of view HDMI Smart TV dongle Mini RF Keyboard
Point of view HDMI Smart TV dongle Mini RF Keyboard English Contents Contents... 1 General notices for use... 2 Disclaimer... 2 Box Contents... 2 1. HDMI TV dongle... 3 1.1. Product display... 3 1.2. Instructions
SoftRAID 5 QUICK START GUIDE. for OWC ThunderBay
SoftRAID 5 QUICK START GUIDE for OWC ThunderBay TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.2 FEATURES 1.3 ABOUT THIS MANUAL SYSTEM SETUP...2 2.1 GETTING STARTED 2.2 INITIALIZING,
Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS
+ Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,
FCC COMPLIANCE STATEMENT
MEDIA CONVERTER Fiber to UTP Ethernet Media Converter ET90110SC ET90110ST Instruction Guide * Actual product may vary from photo Revised: December 6, 2002 The Professionals Source For Hard-to-Find Computer
ES-CAM2A IP Camera. www.etiger.com
ES-CAM2A IP Camera www.etiger.com EN Box content - ES-CAM2A x1 - Mounting bracket x1 - AC Adaptor x1 - User Manual x1 and apps Before using the ES-CAM2A, download the app isecurity+ on the App Store or
TYXIA. *2702178_Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF 642-1 channel
Installation and User Guide TYXIA Wireless receiver TYXIA RF 642-1 channel DELTA DORE Bonnemain - 35270 COMBOURG - France E-mail : [email protected] Unit compliant with the requirements of directives:
Safety Precautions WARNINGS
Safety Precautions This guide contains a variety of safety markings related to the safe and correct operation of the USB Data Transfer Cable. Be sure to read this guide and any related manuals carefully
E&P HYDRAULICS Remote control EPRC-01 Level System Camper
USER S GUIDE E&P HYDRAULICS Remote control EPRC-01 Level System Camper 1 Copyright 2012, E&P Hydraulics This manual is copyrighted, with all rights reserved. Under the copyright laws, this may not, in
Kinivo 301BN HDMI Switch
Kinivo 301BN HDMI Switch User Manual 2012 Kinivo LLC. All rights reserved. Kinivo is a trademark of Kinivo LLC. Bluetooth word mark and the Bluetooth logo are registered trademarks of Bluetooth SIG. All
SPY-BATT Battery Tutor Device Installation Manual Rev. 1.1-07/04/2016
SPY-BATT Battery Tutor Device Installation Manual Rev. 1.1-07/04/2016 1. GENERAL DESCRIPTION The SPY-BATT is a device that allows to monitor the state of your battery. The SPY-BATT stores over time the
FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7
FAQs Conserve package Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7 FAQs Gateway Can I have someone install my system for me? If you are concerned
Installation & Operation Manual HANDS-FREE BLUETOOTH MEDIA INTEGRATION KIT. Perfect for ANDROID TM
GET CONNECTED Installation & Operation Manual HANDS-FREE BLUETOOTH MEDIA INTEGRATION KIT TranzIt BLU HF ISFM2351 Perfect for ANDROID TM Note to Readers, The information contained within the following documentation
Wave/PC Interactive System USB Adapter Kit. Installation Guide
Wave/PC Interactive System USB Adapter Kit Installation Guide Safety Information 1. Read these instructions for all components before using this product. 2. Keep these instructions for future reference.
CCTR-805-V2 3G Car GPS Tracker-201604
CCTR-805-V2 3G Car GPS Tracker-201604 Welcome to use this real time car GPS tracker CCTR-805G.This product is with GPS module and 2G GSM / 3G WCDMA module (with LBS locate without GPS), that has many new
Key. ➍ Micro USB Port ➎ Operating System Toggle Keys ➏ Foam Screen Protectors. ➊ On/Off switch ➋ Bluetooth Connect Button (flashes when searching)
INSTRUCTION MANUAL ➏ ➋ ➊ Product Features ➎ ➍ ➌ Built-in wireless Bluetooth 3.0 keyboard Compatible across ios, Android, and Windows, enabling you to mix and match with devices Ultra-thin, lightweight
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
125 8880 telstra.com/ppmbb visit a telstra store or partner GETTING TO KNOW YOUR
FOR MORE INFORMATIoN: 125 8880 telstra.com/ppmbb visit a telstra store or partner GETTING TO KNOW YOUR Telstra PRE-paid 4G wi-fi LET S GET THIS SHOW ON THE ROad WHAT S INSIDE Your Telstra Pre-Paid 4G Wi-Fi
Nokia Bluetooth Headset BH-200 User Guide
Nokia Bluetooth Headset BH-200 User Guide 1 9246085 Issue 2 DECLARATION OF CONFORMITY We, NOKIA CORPORATION declare under our sole responsibility that the product HS-58W is in conformity with the provisions
ViviCam 25 Digital Camera User s Manual
ViviCam 25 Digital Camera User s Manual 2010 Sakar International, Inc. All rights reserved. Windows and the Windows logo are registered trademarks of Microsoft Corporation. All other trademarks are the
Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)
CN2HK LIMITED Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003) User Manual Please read this manual before operating this product. After you finish reading this manual,
Model: 308-1412 Manual DC: 080215 WIRELESS COLOR FORECAST STATION
Model: 308-1412 Manual DC: 080215 WIRELESS COLOR FORECAST STATION FRONT VIEW SENSOR TX141TH-Bv2 LED TX Sensor Battery Cover Sensor Battery Compartment 2 AA Buttons Battery Compartment 3 AAA BACK VIEW Battery
Installation & Operation Manual
GET CONNECTED Installation & Operation Manual DEVICE INTEGRATION AND CHARGING KIT TranzIt USB IS32 Note to Readers, The information contained within the following documentation is subject to change without
GSM Autodialer Professional GJD700 Speech & Text Autodialer
Text Edit message GSM Autodialer Professional GJD700 Speech & Text Autodialer Introduction The GSM Autodialer Professional works in conjunction with standard alarm systems and makes use of your preferred
Type Message Description Probable Cause Suggested Action. Fan in the system is not functioning or room temperature
Table of Content Error Messages List... 2 Troubleshooting the Storage System... 3 I can t access the Manager... 3 I forgot the password for logging in to the Manager... 3 The users can t access the shared
SNMP Web Management. User s Manual For SNMP Web Card/Box
SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...
Wi-Fi Router Huawei E5. User Guide
Wi-Fi Router Huawei E5 User Guide 1 Content Modem Description Specification SW installation guide User manual Troubleshooting Terms 2 Modem Description Huawei E5830 HSDPA Wifi-router and a USB modem combined
How To Program An Autodialer
GJD HYL005 GSM Autodialer Instruction Manual Please read these instructions before you start the installation Features: LCD display. Programmable 9 x 32 digit phone numbers for each trigger. 10 second
4 Port VGA Video Audio Switch with RS232 control
4 Port VGA Video Audio Switch with RS232 control VS410RVGAA *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario
Online UPS. PowerWalker VFI 1000R/1U
Online UPS PowerWalker VFI 1000R/1U Manual Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4.
Sierra Wireless AirCard Watcher Help for Mac OS X
Sierra Wireless AirCard Watcher Help for Mac OS X Sierra Wireless AirCard Watcher allows you to manage and monitor the connection between your modem and the network. With Watcher, you can: Determine signal
Installation and Operation Back-UPS 1250, 1300, 1500
Installation and Operation Back-UPS 1250, 1300, 1500 Inventory bu001a Safety and General Information This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with
PREFACE SUMMARY. Mobile Network (GPRS) communication established. No power to the unit or the unit cannot start
PREFACE Thank you for purchasing the GPS turtle. This manual shows how to operate the device: read this manual carefully before using the device. Please note that specification and information contained
WUA-0605 300Mbps Wireless USB Network Adapter
WUA-0605 300Mbps Wireless USB Network Adapter User Manual V1.0 Certification FCC CE FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
BM-Dustdetector. Operation Manual
BM-Dustdetector Operation Manual BM Environmental Engineering VOF The Netherlands: Emrikweg 31 2031 BT Haarlem Phone : +31 23 5424708 Fax : +31 23 5322358 e-mail : [email protected] Technical Support see above
4-Port Pocket. USB KVM Switch with USB 2.0 Hub
4-Port Pocket USB KVM Switch with USB 2.0 Hub Manual - 1 - Index 1. INTRODUCTION... 3 1.1 FEATURES... 3 1.2 PHYSICAL DIAGRAM... 4 1.3 PACKAGE CONTENTS... 4 2. SPECIFICATIONS... 5 2.1 ERAL... 5 2.2 LED
XPanel V2. Remote Control Panel. User Manual. XILICA Audio Design
XPanel V2 Remote Control Panel User Manual XILICA Audio Design Important Safety Instructions 1. READ THESE INSTRUCTIONS All the safety and operating instructions should be read before the product is operated.
Thank you for choosing HUAWEI Mobile WiFi
Thank you for choosing HUAWEI Mobile WiFi Supported functions and actual appearance depend on the specific models you purchased. The illustrations are provided for your reference only. For details about
Security module CG2 User manual
Security module CG2 User manual TRIKDIS, JSC Draugystes str. 17, LT-51229 Kaunas LITHUANIA E-mail [email protected] Web http://www.trikdis.lt This manual is furnished to help You understand Your security
Changers Kalhuohfummi User Manual
Changers Kalhuohfummi User Manual Contents 02 Contents 1. The Changers Kalhuohfummi an introduction to your solar battery 2. Introduction to energy tracking 3. Content and compatibility 4. Controls and
USER MANUAL V5.0 ST100
GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2
Business/Home GSM Alarm System. Installation and User Manual
Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene
EDK 350 (868 MHz) EDK 350U (902 MHz) EnOcean Developer Kit
EDK 350 (868 MHz) EDK 350U (902 MHz) EnOcean Developer Kit EDK 350 User Manual Important Notes This information describes the type of component and shall not be considered as assured characteristics. No