The GD-04K universal GSM communicator and controller
|
|
|
- Cleopatra Miller
- 9 years ago
- Views:
Transcription
1 The GD-04K universal GSM communicator and controller The GD-04K is a universal GSM communicator. It controls and / or reports status of different appliances remotely. Control can be performed by SMS instructions or dialling in. The module is equipped with 2 power outputs with a status or pulse reaction. For status monitoring the GD-04K module has four input terminals which react to grounding (connecting to the GND terminal). Activation / deactivation of an input terminal can be reported as an SMS, dialling in or a combination of both these options to up to 100 authorised telephone numbers. The GD-04K can also be supplemented by a GD-04A backup battery which ensures powering the module when the mains is disconnected. The module allows configuration using a PC with installed GD-Link software (or higher) locally via the USB cable or remotely. It can also be configured by programming SMS. 1. Using the GD-04K The GD-04K module uses four inputs (A D) for SMS reporting (optionally dialling) to predefined telephone numbers. It also offers 2 power relay outputs with options to control them by pre-defined SMS commands or by dialling in according to the settings from authorised numbers or from any (non-authorised) numbers. Relay control: by SMS instructions which can be independently pre-set for switching ON / OFF of each relay output. Both relays can work in status or pulse mode, the mode is selectable in the settings. If pulse mode is selected then based on activation command the output will be switched for interval between 1 s to 10 hrs. Dialling in. Both relays (X and Y) can be controlled by dialling in from a known telephone number. Up to 100 numbers can be stored in the communicator. The GD- 04K doesn t pick up an incoming call but verifies the caller s telephone number. If the caller s telephone number is authorised, the call is rejected and the relay is activated / deactivated as required (when the Impulse reaction is set then for predefined time). Dialling in with limited use. While entering authorised telephone numbers the limit of their use can also be defined for each of them. When the usage limit of a pre-defined number is reached then any other calls are ignored. Reactivation can only be allowed by an administrator (by SMS). This function is suitable as a subscription for entrance to garages and so on. Input status reporting: Sending an SMS report when some of the inputs (A D) are activated / deactivated (connected or disconnected to / from GND). Each input has an option to edit the texts which are reported. An SMS can be sent to all telephone numbers stored in the communicator. For higher alert notice SMS report can also be followed by calling to the numbers to which SMS reports have been sent. Status monitoring. By the SMS command STATUS, the status of all inputs and outputs can be checked when needed. This way is for example possible to check status of connected devices which each status change is not required to report. Caution: The GD-04K is not meant and is not certified as a security device to protect premises. GD-04K MNY51104
2 2. Device description Figure 1: 1 GSM antenna; 2 Mini USB connector for PC connection; 3 Reset jumper; 4 SIM card slot; 5 LED indicators; 6 Flexible tabs; 7 Connector for backup battery the GD-04A cover; 8 Output relay fuses; 9 Input / output and power terminals Terminal descriptions: Low voltage terminals: +12 V Terminal for 12 V DC connection from included adapter (or another external power supply which provides current of at least 0.5 A) GND The common terminal for inputs A, B, C, D and GND for the 12 V A, B, C, D input terminals: Inputs react to connection or disconnection to / from the GND terminal. GD-04K MNY51104
3 All inputs have their own time filter (from 0.5 to 10 hrs) A maximum of 30 V can be connected from an external device to the input terminals (A D). Each input can have its own name. Input activation / deactivation is reported to the predefined telephone numbers and also recorded in the event history. Up to 384 events can be stored with information about input or output activation / deactivation with the source of that event (who / what caused it). Power terminals: X1, X2 (RELAY X) NO contact of the power relay, 230 V / 2.5 A. Y1,Y2 (RELAY Y) NO contact of the power relay, 230 V / 2.5 A. LED indicators: Red indicates GSM module incoming activity Green indicates GSM module outgoing activity + RESET indication Common properties: Both outputs (X and Y) can be switched ON independently for a pre-defined time in an interval from 1 s to 10 hrs (impulse) or permanently. Both relays are galvanically separated from the communicator circuits complying with 4kV safety isolation requirements. 3. Installation and initial setup 1. Select an appropriate place for communicator installation considering the GSM signal strength. 2. The communicator s main board can be simply released by pressing the flexible tabs (6) when you open the front cover. 3. Attach the rear plastic part to the selected place. 4. Put the main PCB back onto the rear plastic part. 5. Insert the SIM card orientation is indicated on the PCB (See also chapter 8. SIM card and its use) Note: The GSM antenna mustn t be shielded by metal objects. The original antenna can be replaced by an external one meant for the GSM band 900/1800 MHz and equipped with an SMA connector, connected by a coax cable with a 50 Ω impedance if needed. 6. Connect the input / output and power wires to the communicator s terminals. Power: Connect the supplied mains adapter to the +12 V and GND terminals (the wire with a grey stripe is for the +12 V terminal). When another power is used, it must provide 12 V DC and a current of at least 500 ma. Don t turn it on yet. GD-04K MNY51104
4 Relay output contacts: These are connected to the terminals labelled X1, X2 and Y1, Y2. Each output is protected by the 5 A fuse. Example: Bulb control by relay Y: Input terminals: labelled as A - D react to (and send an SMS) connection / disconnection to / from the GND terminal. Example: switch connected to the A input terminal: 4. The GD-04A backup cover In case of AC failure an optional GD-04A module (a backup battery is built inside the bigger cover) provides 12 to 24 hours back up time. The exact time depends on GSM signal strength (the stronger the signal is the lower consumption the device has). The 2-pin connector (7) on the GD-04K module serves for connection of the backup cover. The built-in battery is charged from the main unit and fully charged is in approximately 72 hours. The backup module only supplies the GD-04K communicator and its output relays. However it doesn t supply external devices connected to the +12 V terminal. GD-04K module sends SMS report POWER FAIL in case of mains failure or disconnection and POWER RECOVERY when the mains is recovered to all service telephone numbers (see the 6. Settings chapter). Both texts are editable. If the backup battery is discharged the module is shut down (both relays are switched off). When the mains power is recovered the relays previous status is restored and the backup battery is charged. 5. Initial powering up 1. Turn the power on, the red LED starts flashing to indicate logging of the module on to the GSM network (if it doesn t, check the power supply proper connection). 2. The red LED indicator goes off when the device is logged into the GSM network (it takes typically 1 minute). When it keeps flashing, there is some obstacle blocking logging in (turn the power off and check if the SIM card is inserted properly, if it has been activated and if there is enough GSM signal strength). GD-04K MNY51104
5 3. Send the SMS command: STATUS from your cell phone to the SIM card inserted into the GSM communicator. 4. The communicator answers by SMS like this: STATUS: A0,B0,C0,D0,X0,Y0, GSM:80%, Vcc:12.1 V (which means that all inputs and both relay outputs are deactivated/switched off, the GSM signal strength is 80% and the power voltage is 12.1 V). The response speed depends on current GSM network traffic. With no response, check if the text STATUS has been written correctly and sent to the correct telephone number. 6. Settings 6.1. Local setting using PC The most comfortable way of settings the GD-04K is by computer and GD-Link (or higher) software which allows saving the settings for the later use. Programming SW is free for download from The software requires a Windows XP operating system or newer. When connected to the Internet, GD-Link checks whether a new version of the GD-Link is available. In such case an update is offered immediately. The current FW which is part of the GD-Link package is also downloaded and once the GD-04K is connected to the PC automatic upgrade is offered. A FW upgrade can be performed also manually by clicking on the option Device / Firmware update from the file. Connection procedure: Connect a PC using the supplied USB cable with the miniusb connector (2) on the communicator s main board. Start the GD-Link SW or higher. According to the settings, the required action in the initial window can be chosen or the communicator is connected automatically. If the setting is modified offline without connected GD-04K, then to go online press the button Online on the upper toolbar when the unit is connected. Figure 2 GD-04K MNY51104
6 The software includes 7 tabs: Users A tap to set up to 100 users with telephone numbers, reports and authorisation to control. Inputs A tab where all parameters related to inputs A, B, C, D can be configured such as texts for reporting via SMS, etc. Output A tab where all parameters related to X and Y outputs can be configured such as texts for control the outputs, reactions, etc. Settings A tab which includes advanced settings of the communicator, for example service telephone numbers, pre-paid SIM card credit balance checking, etc. Texts A tab meant for editing system texts reported via SMS according to user requirements. Default texts are in the English language. Information A tab where production codes and the registration key are stored. The reg key is necessary to perform remote access via GD-Link software. Events A displays event history with a date of creation and source of event. Note: For detail description of all options the software has Tooltips. It is visible when you move the mouse cursor over any parameter Remote access using a PC The GD-04K device can be also configured by a PC using GD-Link (or higher) software remotely through the Internet. For that it is necessary to know the registration code and telephone number of the SIM card used in the communicator (figure 3). To establish a remote connection with a device use the Internet button in the upper software toolbar. Warning: During remote access GPRS data is used, which can be charged by your GSM provider. Therefore before performing remote access check GPRS data payments details with the GSM provider. Remote programming allows all parameters to be set as if you are connected locally using a USB cable. Figure 3 GD-04K MNY51104
7 6.3. Remote setup using the setup webpage The GD-04K module can also be programmed by the setup webpage david.jablotron.cz/gd-04/ where you can fill in the basic parameters and send those settings to the communicator (options marked in red are not supported by the GD-04K). The setup page allows only to send new setting but it is not possible to read current setting from a device. That s why we strictly recommend to save the current settings ready to be sent to the GD-04K before leaving the web page ( Save the settings in your computer for future use -> Save ). When the communicator receives new setting then a factory RESET is performed and the setting is uploaded. All programming options which are not filled in will be erased. Therefore it is always necessary to fill in all the required options not only the one which is to be changed. The best way of programming the GD-04K remotely is by using GD-Link software and higher, see chapter Setup using SMS The GD-04K basic functions can also be programmed by SMS instructions, see the example: PC, ARX, heating ON, DRX, heating OFF where: PC is the password, every programming SMS has to begin with (default password is PC, it can be changed, maximum 2-30 characters, no diacritics), is a comma which separates every instruction or command form ARX is the instruction for relay X to be switched ON, followed by a comma DRX is the instruction for relay X to be switched OFF, followed by a comma This programming SMS sets up the X relay to be switched ON / OFF by the SMS commands heating ON and heating OFF. An overview of all programming instructions is given in table 1 (at the end of this instruction manual). Rules valid for configuration SMS instruction use: 1. If you want to send more than one programming SMS, then every SMS has to begin with a valid password. 2. More instructions can be included in one programming SMS. The device can manage a long SMS and it means that a programming SMS can include up to 2400 characters with no diacritics or 1050 characters with diacritics. 3. Every instruction has to be separated by a comma and none must be put at the end of the instruction command. 4. Spaces in the programming SMS are ignored except the spaces in programmed texts. 5. When a programming SMS is received and processed, the GSM communicator answers back with PROGRAM OK (this text can be edited). 6. If the GSM communicator detects a syntax error in the received programming SMS it answers with PROGRAM ERROR (this text can be edited) and forwards the invalid syntax back to the sender. All valid instructions are performed and the unrecognized part of the texts is ignored. 7. Capital and small letters are treated equally. GD-04K MNY51104
8 8. Diacritics are also not recognized. 9. After a programming SMS has been received the GD-04K switches off both relays (X and Y). 7. Remote control 7.1. Relay remote control using SMS instructions Text commands for controlling (switching ON / OFF) the outputs by SMS can be customized. Up to 30 characters can be used. Pre-defined texts are used as commands with the following conditions: SMS command is without password and must exactly match the predefined text. Capital and small letters are treated equally. Using GD-Link software (or higher) can be set for SMS and for dialling-in independently for each relay whether it can be controlled by anybody or only from authorised numbers stored in the device. Multiple SMS commands can be written in one SMS, commands are separated by a comma. Example: HEATING ON, LIGHTS OFF, STATUS The communicator confirms command processing by a confirmation SMS. An unrecognized SMS can be forwarded to the service number (see Settings). When using an SMS internet gate an SMS can have other text added to the wanted command. It is then necessary to mark the beginning of the command by the symbol % and finish with %%. For example an SMS with the text: www: %heating on%% -- SMS sent by your GSM provider. is processed by the communicator to be the command: heating on Relay remote control by dialling in It is possible to set telephone numbers to control output relays by dialling in. If this authorised number calls, the relay reacts this way: If the relay has a pre-defined limited switching time (Impulse reaction) then on dialling in occurring it switches on for that time. If the switching time is set to zero, dialling in switches it ON until it is dialled in again then the relay switches OFF (or it can also be switched OFF by sending an SMS with a command meant for switching off). Using GD-Link software (or higher) can be set for SMS and for dialling-in independently for each relay whether it can be controlled by anybody or only from authorised numbers stored in the device. Up to 100 telephone numbers can control both relays if this option is enabled. For every telephone number you can set the maximum number of uses. When a preset limit has been reached, the telephone number can not be used to control more. Control by dialling in can only be realized by phone numbers with enabled caller ID visibility (telephone number is not hidden). Sending a confirmation SMS can be set to happen when the relay has been controlled by dialling in. GD-04K MNY51104
9 8. SIM card and its use A normal 2G SIM card from any provider can be used. Before you start using the SIM card with the GSM communicator, check the SIM card s functionality in your cell phone by making a call (not just dialling in) and send an SMS. Disable the PIN code requirement on the SIM card or pre-set its PIN code to Check the GSM signal strength at the installation place. It is not recommended to use pre-paid SIM cards, because it increases the risk of failure because of exhaustion of credit or expiration of credit validity. If you do decide to use a pre-paid SIM card, the device can check the credit balance automatically. The communicator checks (at a pre-defined frequency) the credit balance and if the credit is lower than the preset minimum, then the current credit balance is forwarded to the service telephone number. For correct functioning it has to be set according to the parameters given by your GSM provider. Setting is performed by the instruction: PC, CRD, xxxx, dd, hhh, pp where: PC is the programming password CRD is the command for getting the credit balance xxxx is the USSD command for credit balance requirement, depends on the GSM provider dd is the period, how often the credit balance is checked (in days) hhh is the minimum credit balance pp is the position of the credit info in the text in the GSM provider s answer Example: To check for a minimum credit of 30 EUR once a week set like this: PC, CRD, *104*#, 7, 30, 1 To check the current credit balance use the SMS command: PC, CRD To erase automatic credit balance checking, program all options to 0, this way: PC, CRD, *104*#, 0, 0, 0 Warning: The examples mentioned here for credit balance checking might not work if the GSM provider changes their format. Check the way to get a credit balance and in which format the GSM provider answers to the request. 9. Factory reset Can be performed remotely by the SMS instruction PC, RST, where PC is the programming password see table 1. Another option is to perform it using the RESET jumper (placed next to the SIM card holder). GD-04K MNY51104
10 Turn the power off (backup cover as well, if used). Put the jumper on the RESET pins Turn the power on (green LED starts flashing) and Wait until the LED indicates permanently (after approx. 5 sec), then take the jumper off the reset pins. When a reset is performed all settings are erased, including telephone numbers and texts. 10. Technical specifications Power V DC Consumption in standby approx. 25 ma (+17 ma per relay) Max. device consumption during GSM communication 200 ma GSM module operation band E-GSM 850 / 900 / 1800 / 1900 MHz GSM RF output power 2 W for GSM 850 / W for GSM 1800 / 1900 Triggering of inputs A, B, C, D connection to GND X and Y outputs load: - resistive load max. 2.5 A / 250 V AC - inductive (capacitive), bulb load max. 0.5 A / 250 V AC Can be operated according to ERC REC Safety EN EMC EN , EN and EN Radio emissions ETSI EN Operational environment II. Indoor general (-10 C to +40 C) Dimensions (no antenna) 76 x 110 x 33 mm GSM antenna connection by SMA connector This product complies with the essential requirements of: RTTE Directive 1999/5/EC, 2011/65/EU, when used for its intended purpose. The original of the conformity assessment can be found at Technical Support section. Note: Although this product does not contain any harmful materials we suggest you return the product to the dealer or directly to the producer after use. GD-04K MNY51104
11 11. Table 1 SMS programming instructions overview A programming SMS always has to begin with the password (see 6.4). Example: PC, ARX, heating ON, DRX, heating OFF Purpose / function SMS to switch relay ON SMS to switch relay OFF Relay switch-on period Telephone numbers authorised for relay control Telephone numbers authorised for relay control with a validity limit Instruction Description X and Y relay control ARX, xxx..x For relay Y enter ARY, xxx..x = text up to 30 characters, Erase text by entering ARX, Example: ARY,ventilation ON DRX, xxx..x For relay Y enter DRY, xxx..x = text up to 30 characters, Erase text by entering DRX, Example: DRY, ventilation OFF TMX, t..t For relay Y enter TMY, t..t = switch on time in seconds or minutes (m) or hours (h) from 1 to 10 hrs (3600 = 60 m = 1 h). When time is set then relay starts working as a timer switch, activated via switch-on SMSes or dialling-in, deactivated by time-limit expiration or via switch-off SMSes. When the time is set to 0 then relay behaves as a toggle contact: on, off, on, Example: TMX, , 5m ADX, x..x,x..x For relay Y enter ADY, x..x = tel. number, can be entered up to 100 tel. numbers (in a single instruction or gradually). The numbers are added to the list of authorised numbers. Example: add new numbers for relay X control: ADX, , LDX, x..x,n, For relay Y enter LDY, x..x, n where: x..x,n x..x = tel. number (up to 100 tel. numbers can be added), numbers are added to the list of authorised numbers, n = limit in the number of calls (1 to 99), exceeding the limit removes the number from the list and reports this to the service number by SMS number erased. Example: add the numbers for relay X control for a maximum of 31 calls: LDX, , 31 Factory settings None None 0 (no limit) None None GD-04K MNY51104
12 Erasing tel. numbers authorised for relay control Input activation text Input deactivation text Telephone numbers for input reports Input event calls New programming password SMS to get GD- 04K status text change Service telephone numbers EDX, x..x, x..x For relay Y enter EDY, x..x = tel. number (up to 100 number can be erased). Example: erase telephone number for controlled relay X by dialling in: EDX, SMS reporting initiated by triggering of the A D inputs ATA, xx..x For B input enter ATB etc., xxx..x = text, up to 30 characters To erase text: ATA,, (no text = no activation reporting) Example: ATC, heating on DTA, xx..x For B input enter DTB etc., xxx..x = text, up to 30 characters To erase text enter: DTA,, (no text = no deactivation reporting) Example: DTC, heating off TNA, x..x, x..x For B input enter TNB etc., x..x = tel. number, up to 100 for each input. All previously stored numbers are erased. To erase all numbers for input enter: TNA,., Example: TND, , , sets the GD-04K to report input D events to 2 numbers DNA, n For B input enter DNB etc., n = 1 (ON), 0 (OFF). If set to ON, every SMS report is followed by a call. Example: DND, 1 Other functions NPC, xx x xx x = new programming password, from 2 to up to 30 characters Example: NPC, MARTIN27 STS, xx..x xxx..x = text, up to 30 characters* Example: STS, HOW ARE YOU STN, x..x, x..x xxx..x = tel. number, Up to 2 numbers can be set, previously set numbers are erased. Service numbers are used to report faults: POWER FAIL / POWER RECOVERY LINE OK (GSM signal recovery) Other events see Optional functions To erase the service number enter: STN,., None A1, B1, C1, D1 A0, B0, C0, D0 None Disabled PC STATUS žádné GD-04K MNY51104
13 Optional functions GSM module restart DIP,a,b,c,d,e,f,g GSM Parameter a to f values can be: 1=ON, 0=OFF, x=unchanged. Description of the parameters: a Forward unrecognised SMSes to the service number b Periodic calls to the service number every 24 hours (from the moment of being set) c Forward all SMSes to the service number d Max. 10 SMSes within 15 minutes (all subsequent SMS requests ignored for the next 1 hr) e SMS reporting of relay control by dialling in f SMS reporting of relay control by SMS (e.g. heating OFF OK g Not used (always enter 0) Example: DIP,1,x,x,x,x,1,x The GD-04K will log out and then log in to the GSM network. This can be useful after a blocked SIM card has been unblocked. A restart is also triggered by briefly connecting the RESET jumper while the GD-04K is being powered up. Reset RST Resets the GD-04K to the factory default settings it can also be performed by connecting the RESET jumper during powering up - (disconnect the jumper after approx. 5 s) All disabled GD-04K MNY51104
14 NOTES: GD-04K MNY51104
15 NOTES: GD-04K MNY51104
16
The GD-04 David GSM communicator
The GD-04 David GSM communicator User manual The GD-04 module got its name from David, a biblical king who outsmarted Goliath, a giant. In our case, Goliath is meant to be the GSM network. We hope that
Operating Instructions
Operating Instructions Kühn Controls AG, Gräfenhäuser Str. 14, D-75305 Neuenbürg, Germany Tel. +49 (0)7082-94 00 00 www.kuehn-controls.de [email protected] Fax +49 (0)7082-94 00 01 Content 1. SMS
GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G WI-FI
GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G WI-FI LET S GET THIS SHOW ON THE ROAD You must be excited about your brand new Telstra Pre-Paid 3G Wi-Fi. This guide will help you get connected as quickly and
Business/Home GSM Alarm System. Installation and User Manual
Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene
GSM HOME SECURITY SYSTEM
Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : GSM-120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5.
GSM Smart Switch USER GUIDE
GSM Smart Switch USER GUIDE GSM Smart Switch allows switching almost any appliance ON and OFF remotely via mobile network. It is designed to receive start/stop commands from specially coded messages or
Falcon Protector Tracking System
Falcon Protector Tracking System Product Overview The Falcon Protector is a GPS and GSM tracking device which is specially developed and designed for vehicle tracking. With the latest SIFR III GPS module
FOR MORE INFORMATION. 125 8880 or from a non-telstra phone 13 2200 and say pre-paid telstra.com/ppmbb visit a telstra store or partner
FOR MORE INFORMATION 125 8880 or from a non-telstra phone 13 2200 and say pre-paid telstra.com/ppmbb visit a telstra store or partner getting to know your telstra pre-paid 4G WI-FI (760S) LET S GET THIS
GSM Alarm System User Manual
GSM Alarm System User Manual For a better understanding of this product, please read this user manual thoroughly before using it. Quick Guider After getting this alarm system, you need to do the following
GETTING TO KNOW YOUR PRE-PAID TELSTRA WI-FI 4G
GETTING TO KNOW YOUR PRE-PAID TELSTRA WI-FI 4G LET S GET THIS SHOW ON THE ROAD You must be excited about your brand new Pre-Paid Telstra Wi-Fi 4G. This guide will help you get connected as quickly and
Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO
GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module
GSM Remote control. Version W-BUS v9.x. Operating manual
GSM Remote control Version W-BUS v9.x Operating manual Antenna Status LED Release SMA Connection SIM card Front view Release PIN 1 PIN 8 Back view Table of contents 1 Scope of delivery...4 2 Safety instructions...5
VIVA 4G LTE Mini Router. Quick Start Guide
VIVA 4G LTE Mini Router Quick Start Guide Thank you for choosing the VIVA 4G LTE Mini Router (hereinafter referred to as the E57) The supported functions and actual appearance are subject to the product
125 8880 telstra.com/ppmbb visit a telstra store or partner GETTING TO KNOW YOUR
FOR MORE INFORMATIoN: 125 8880 telstra.com/ppmbb visit a telstra store or partner GETTING TO KNOW YOUR Telstra PRE-paid 4G wi-fi LET S GET THIS SHOW ON THE ROad WHAT S INSIDE Your Telstra Pre-Paid 4G Wi-Fi
Operating Instructions Thermo Call TC3. General Information. Use. Dear Webasto customer,
Operating Instructions Thermo Call TC3 General Information Dear Webasto customer, Thank you for purchasing the new Thermo Call TC3. This product provides you with a convenient, innovative way to operate
F2103 GPRS DTU USER MANUAL
F2103 GPRS DTU USER MANUAL Add:J1-J2,3rd Floor,No.44,GuanRi Road,SoftWare Park,XiaMen,China 1 Zip Code:361008 Contents Chapter 1 Brief Introduction of Product... 3 1.1 General... 3 1.2 Product Features...
GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G USB + WI-FI
FOR MORE INFORMATION CALL 125 8880 or FROM A NON-TELSTRA PHONE, CALL 13 2200 AND SAY PRE-PAID VISIT telstra.com/ppmbb VISIT A TELSTRA STORE OR PARTNER GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G USB + WI-FI
CCTR-805-V2 3G Car GPS Tracker-201604
CCTR-805-V2 3G Car GPS Tracker-201604 Welcome to use this real time car GPS tracker CCTR-805G.This product is with GPS module and 2G GSM / 3G WCDMA module (with LBS locate without GPS), that has many new
USER MANUAL V5.0 VT300
GPS Vehicle Tracker USER MANUAL V5.0 VT300 Updated on 26/12/2008 Contents 1 Product Overview 3 2 For Your Safety 3 3 VT300 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2 Light and
GSM Autodialer Professional GJD700 Speech & Text Autodialer
Text Edit message GSM Autodialer Professional GJD700 Speech & Text Autodialer Introduction The GSM Autodialer Professional works in conjunction with standard alarm systems and makes use of your preferred
CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual
CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CGWTS-M001A Version 1, Release 1, December 2004 NOTICE
EST-64 GSM Remote Control Device User Manual E E S S T T A A T T E E S S W W I I N N G G
EST-64 GSM Remote Controll Deviice User Manual EESSTTAATTEE SSWIINNGG Electronic KIT to convert your gate into a GSM gate EST-64 GSM Remote Control Device Diagram 2 1. INTRODUCTION EST-64 GSM Remote Control
Danfoss Link Mobile Phone Butler
MAKIG MODER LIVIG POSSIBLE Installation Guide www.heating.danfoss.com Table of Contents 1 Introduction... 3 2 Installation... 3 3 Interfaces... 4 4 Wiring... 4 5 SMS Commands... 5 6 Technical Specifications...
Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)
CN2HK LIMITED Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003) User Manual Please read this manual before operating this product. After you finish reading this manual,
GSMPBX version 1.3 Datasheet
GSMPBX version.3 Datasheet Document Rev.:.3 Revision Date: 23.03.203 (preliminary data) Figure - GSMPBX Introduction The GSMPBX is designed to commute phone calls between a cellular network (GSM) and the
MANUAL GSM CONTROLLER
MANUAL GSM CONTROLLER CallFree2 CallFree 3G 2 outputs, 3 inputs ` Please read these instructions completely before use GSM CallFree 1/17 Revision V1.3C, Aug 2015 TABLE OF CONTENTS 1. SAFETY PRECAUTIONS...
GSM-AUTO+ GSM Controller with Internal Power Supply User manual
GSM-AUTO+ GSM Controller with Internal Power Supply User manual INDEX Description... 2 Preparing the SIM card... 3 Installation... 4 Example connections... 5 Programming commands... 6 Quick reference of
Intelligent GSM Auto-dial Alarm System User s Manual
Intelligent GSM Auto-dial Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. [Function Instruction] [Control Panel Introduction]
How to connect your D200 using Bluetooth. How to connect your D200 using GPRS (SIM Card)
D200 En User Guide Content 3 Introduction 3 Scope 3 Related Documentation 4 Internet Connectivity 4 Using D200 with Mobile Phone 5 Using D200 with wireless (Wi-Fi) router 6 Using D200 with GPRS (requires
Business/Home GSM. Alarm System(III) Installation and Users guide
Business/Home GSM Alarm System(III) Installation and Users guide I. General information: GSM 900/1800/1900 bands, can be used all over the world. Full duplex communication with the base. Monitor environment
GSM Controller User manual
GSM-AUTO GSM Controller User manual INDEX Description... 2 Preparing the SIM card... 3 Installation... 4 Example connections... 5 Programming commands... 7 Quick reference of programming commands....12
INSTALLATION MANUAL XM3 Reader
INSTALLATION MANUAL XM3 Reader Conditions Transactions, deliveries et cetera will be according to the general terms of delivery as deposited at the Chamber of Commerce at Meppel, The Netherlands. Registration
GDI User and programming manual V 2.0
G S M D O O R I N T E R C O M GDI User and programming manual V 2.0 Basic technical parametres: Power supply: 12 (9-24) V AC/DC, 500mA (optionally integrated ACU 2000mAh for cca 48h of operation) GSM :
GSM Gate Control 1000
GSM Gate Control 000 INSTALLATION AND APPLICATION MANUAL for module version v3.3 and higher Manual version:.7 24.06.20 Features: Control of relay outputs with free calls using caller identification Capacity
How to setup a serial Bluetooth adapter Master Guide
How to setup a serial Bluetooth adapter Master Guide Nordfield.com Our serial Bluetooth adapters part UCBT232B and UCBT232EXA can be setup and paired using a Bluetooth management software called BlueSoleil
Intelligent Alarm System
Intelligent Alarm System User Manual Ver 12-3 Dear users, Thank you for having selected the intelligent alarm system. Please read through this manual before installation so as to operate properly. The
Business/Home. GSM Alarm system
Business/Home GSM Alarm system Installation and Users guide Profile For a better understanding of this product, please read this user manual thoroughly before using it. I. General information: GSM 900/1800/1900
Sierra Wireless AirCard Watcher Help for Mac OS X
Sierra Wireless AirCard Watcher Help for Mac OS X Sierra Wireless AirCard Watcher allows you to manage and monitor the connection between your modem and the network. With Watcher, you can: Determine signal
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
Intelligent GSM Auto-Dial Alarm System
Auto-dial Alarm System Intelligent GSM Auto-Dial Alarm System Profile For a better understanding of this product, please read this user manual thoroughly before using it. 2013.2.V1.0 Auto-dial Alarm System
STATUS POWER MONITOR ALARM SOS DISARM
STATUS POWER MONITOR ALARM SOS DISARM I. Features II. Preparation before use III. Host 1.LED status explanation 2. Host panel IV. System Settings 1. Coding of wireless sensors 2. Exit coding 3. Settings
Installation and setup guide V 1.0
V o I P G S M G A T E BlueGate SIP 1 Installation and setup guide V 1.0 1. General description 1.1 Technical parametres Dimensions 100 x 130 x 37 mm Weight 850 g Operating position various Operating condition
Rev 06 1211. GSM base station. Installation instructions
Rev 06 1211 GSM base station Installation instructions Output string format Baud rate 115200 bps Parity none Data bits 8 Stop bits 1 Flow control none The output string is a modified version of the Sureguard
User Manual. Genius GPS / GSM 810 Real Time GPS Tracker. Android App Download. Iphone App Download ENGLISH. Genius Advanced Technologies
Genius GPS / GSM 810 Real Time GPS Tracker User Manual Android App Download Iphone App Download www.geniuscaralarm.com 1 Genius GPS / GSM 810 Real Time GPS Tracker Welcome to use this real time car GPS
User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
TDG134 - GSM Gate Control
USER MANUAL TDG134 TDG134 - GSM Gate Control Technical data GSM / GPRS Module: SIM900 Quad (850/900/1800/1900 MHz) GPRS multi-slot class 10/8 GPRS mobile station class B Output power: Class 4 (2 W @ 850-900
GSM ATT Modules Simply effective remote control
GSM ATT Modules Simply effective remote control To control electrical loads via mobile phone The benefits Remote management of electrical devices is an increasingly widespread requirement in residential
Car Alarm Tracker Manual-20150814
CCTR-922 Car Alarm Tracker Manual-20150814 Welcome to use this GSM car alarm with tracker function CCTR-922. this product use 2G GSM network (LBS locate) to locate the car, it has many new and unique functions,
GUARD SENIOR. manual
GUARD SENIOR LISA manual Table of Contexts Basic description... 2 General Precautions... 2 SIM card install... 2 PC software install... 3 Running GUARD SENIOR LISA software...15 Configuration window...
Ericsson W25. Mobile Networks. Quick Installation Guide
Ericsson W25 Fixed Wireless Terminal for WCDMA/HSDPA Mobile Networks Quick Installation Guide Table of Contents INTRODUCTION... 3 Package Contents... 3 Requirements... 3 INSTALLATION... 4 Unit Preparation...
CCTR-810 Real Time Car GPS Tracker
CCTR-810 Real Time Car GPS Tracker Welcome to use this Real Time Vehicle GPS tracker CCTR-810 & tracking system. This product integrates GSM and GPS Module. So it can achieve many functions through our
GSM remote controller v7.0 / v7.0 PRO. Operating Instructions
GSM remote controller v7.0 / v7.0 PRO Operating Instructions Table of contents 1 Delivery content...3 1.1 optional accessories...3 2 Safety...4 3 Intended use...4 4 responsibility and liability...5 5 Malfunctions...5
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
WITURA CORPORATION SDN BHD
WT 1010SA Stand Alone GSM Alarm System User Manual and Installation Instructions Version: 1.2 Updated: 4 JAN 2012 WITURA CORPORATION SDN BHD Stand Alone GSM Alarm System Instruction Manual 1 Introduction:
808 Vehicle Real Time GPS Tracker
808 Vehicle Real Time GPS Tracker Welcome to use this Real Time GPS tracker CCTR-808, This product is with GPS module and GSM module, It has many new and unique functions, such as real time uploading current
LA-9011 GSM/GPS Tracker User Manual
LA-9011 GSM/GPS Tracker User Manual GSM/GPS Tracker A GSM and GPS Tracking solution to locate and track the whereabouts of your vehicle in real time via the Internet on a computer or Smart phone. The device
Link Gate SIP. (Firmware version 1.20)
Link Gate SIP (Firmware version 1.20) User guide v1.0 1 Content 2 1. Technical parameters - Dimensions 133 x 233 x 60 mm - Weight 850 g - Operating position various - Operating condition temperature: +5
Plena Voice Alarm System. Software Manual Configuration Software
Plena Voice Alarm System en Software Manual Configuration Software Plena Voice Alarm System Software Manual Table of Contents en 3 Table of Contents Table of Contents...3 1. Introduction...7 1.1 Purpose...7
RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP
RouteFinder SOHO SOHO Security Appliance EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP Quick Start Guide RouteFinder RF825 Series Quick Start Guide RouteFinder SOHO Security Appliance
USER MANUAL V5.0 ST100
GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2
IRIS Touch 600 Range Dialler Installation Manual. Version 1.3
IRIS Touch 600 Range Dialler Installation Manual Version 1.3 The information contained is supplied without liability for any errors or omissions. No part may be reproduced or used except as authorised
Thank you for purchasing the Huawei E5332 Mobile WiFi. This quick start guide will help you to get started right away.
Thank you for purchasing the Huawei E5332 Mobile WiFi. This quick start guide will help you to get started right away. You can connect your Huawei E5332 to the internet through any WiFi enabled device
FN2001-A1 Network module (SAFEDLINK) Mounting Installation
FN00-A Network module (SAFEDLINK) Mounting Installation A6V050_f_en_-- 05-0-6 Building Technologies Division Legal notice Legal notice Technical specifications and availability subject to change without
INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM
INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM Revised: August 28, 2014 PRODUCT REFERENCE MOUNTING ACCESSORIES PIR / MOTION DETECTION UNIT MAIN UNIT POWER ADAPTER MOUNTING ACCESSORIES
200 Range Dialer Installation Manual. Version 1.0
200 Range Dialer Installation Manual Version 1.0 The information contained is supplied without liability for any errors or omissions. No part may be reproduced or used except as authorised by contract
Type Message Description Probable Cause Suggested Action. Fan in the system is not functioning or room temperature
Table of Content Error Messages List... 2 Troubleshooting the Storage System... 3 I can t access the Manager... 3 I forgot the password for logging in to the Manager... 3 The users can t access the shared
Mobile Satellite Solutions. A WiWorld Partner SATELLITE TV ANTENNA CONTROLLER RFM-1000/1100 TECHNICAL MANUAL STOW SEARCH
Mobile Satellite Solutions A WiWorld Partner SATELLITE TV ANTENNA CONTROLLER RFM-1000/1100 TECHNICAL MANUAL SEARCH STOW Ver. 1 June 2012 WARNING Make all electrical and coax connections from the controller
ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System
ELITE-L Series ELITE - Low Voltage / Dry contact Remote Control System Applications Garden Lighting Pond pumps Remote outdoor Switching Access control Industrial control Features 4 switched channels 1000W
B890 4G LTE Smart Hub Getting Started Guide
B890 4G LTE Smart Hub Getting Started Guide HUAWEI TECHNOLOGIES CO., LTD. Thank You for Purchasing the B890 4G LTE Smart Hub! Before You Begin What s in the Box : 1. B890 4G LTE Smart Hub 2. Power adapter
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
User s Manual. Powerline 200M Ethernet Bridge
User s Manual Powerline 200M Ethernet Bridge Index 1. Powerline Networking Installation...2 1.1 Simple step to install Powerline Networking...2 1.2 Application Block Diagram...3 1.3 Benefits...5 1.4 Features...5
USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES
USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES 204.CAxxx 204.CBxxx 204.UBxxx 204.WBxxx MP36289 1 ZP90856-GB-6 INDICE 1 SYSTEM DESCRIPTION... 4 1.1 MODES OF OPERATION... 4 2 USER INTERFACE... 6 2.1
EWR2 WIRELESS SIGNAL REPEATER
SIGNAL REPEATER User manual v1.2 Compatible with: ESIM364 v02.07.11 and up EPIR3 v01.01.00 and up EWP1 v16 and up EKB3W v8 and up EW1 v33 and up EWS1 v16 and up EWD1 v19 and up EWK1 v19 and up EWS2 v15
New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.
New GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Chapter 1. Features Chapter 2. Alarm Host Introduction Chapter
Installation Instructions For Controllers with MS/TP Automatic MAC Addressing. Patent Pending 000-019-01
Installation Instructions For Controllers with MS/TP Automatic MAC Addressing Patent Pending 000-019-01 KMC Controls Important notices Disclaimer 2009, KMC Controls, Inc. TotalControl, BACstage and FullBAC
CCTR-811 Vehicle GPS Tracker
CCTR-811 Vehicle GPS Tracker Welcome to use Real Time GPS tracker CCTR-811, This product is with u-blox GPS module and GSM module, it can upload current location to website, display history tracking on
A RF18 Remote control receiver MODULE
A RF18 Remote control receiver MODULE User Guide No part of this document may be reproduced or transmitted (in electronic or paper version, photocopy) without Adeunis RF consent. This document is subject
Thank you for choosing HUAWEI Mobile WiFi
Thank you for choosing HUAWEI Mobile WiFi Supported functions and actual appearance depend on the specific models you purchased. The illustrations are provided for your reference only. For details about
DVB-T2 DIGITAL TV BOX
DVB-T2 DIGITAL TV BOX QUALITY OF DIGITAL TELEVISION MT4159 User Manual EN 2 Index Index...2 Introduction...3 Front panel...3 Rear panel...3 Remote control...4 Hardware configuration...5 Connecting tuner
PCS300 Universal IP Reporting Module V1.0
PCS300 Universal IP Reporting Module V1.0 Reference and Installation Manual Patents: One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111,
Red Box and Flarm interface for LX 5000 with optionally SD-card interface and IGC approved flight recorder User manual
LX Red Box and Flarm interface for LX 5000 with optionally SD-card interface and IGC approved flight recorder User manual 1 Introduction...3 2 Technical data...3 2.1 Part list...4 2.1.1 Flarm Red Box...4
500r+ Installation and User Guide
500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and
Microprocessor Home Security System
numbers of sensor s activations in the zone and after which activations the zone will be discarded (ignored). On every system s arming the counter is cleared in self. 6.3.11. 2 - Triger Timer - enter a
Tebis application software
Tebis application software Input products / ON / OFF output / RF dimmer Electrical / Mechanical characteristics: see product user manual Product reference Product designation TP device RF devices WYC81xQ
IN-OUT Thermometer with Cable Free Sensor and Clock
IN-OUT Thermometer with Cable Free Sensor and Clock MODEL: RAR232 USER'S MANUAL INTRODUCTION Congratulations on your purchase of the RAR232 In-Out Thermometer with 433MHz cable free sensor and calendar
Link SIP Door Phone. Manual V1.0. Linkcom France. 1 11 rue du Soleil Levant 92140 CLAMART Copyright 2008 Linkcom Tous droit réservés
Link SIP Door Phone Manual V1.0 1 Table of Contents 1. BASIC DESCRIPTION...3 1.1. FEATURES... 3 1.2. MODULE ASSEMBLY... 3 2. MODULE FEATURES...4 2.1. BASIC MODULE... 4 2.2. RELAYS CONNECTION... 4 2.3.
Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A
COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850
BlueGate SIP. VoIP GSM Gate. Quick Installation guide v 1.0
ALPHATECH TECHNOLOGIES s.r.o. Jeremenkova 88, Praha 4, Czech Republic www.alphatechtechnologies.cz BlueGate SIP VoIP GSM Gate Quick Installation guide v 1.0 Technical parametres Dimensions Weight Operating
GSM Desktop phone DPH101. User manual v1.00
GSM Desktop phone DPH101 User manual v1.00 LEGAL NOTICE Copyright 2011 TELTONIKA Ltd. All rights reserved. Reproduction, transfer, distribution or storage of part or all of the contents in this document
GLENSOUND ELECTRONICS LTD
GLENSOUND ELECTRONICS LTD GS-MPI004 GSM Beltpack Unit & GS-MPI005 GSM Subrack Unit DATE 25/03/08 ISSUE No. 2 HANDBOOK CONTENTS DESCRIPTION PAGE No. Panel Drawings & Block Diagram...2 GS-MPI004 Front &
GPS Vehicle and personal location tracker. User manual
GPS Vehicle and personal location tracker User manual 1 Contents 1. Product overview... 2 2. Safety instruction... 3 3. Specification and parameters... 3 4. Getting started... 4 4.1 Hardware and accessories...
HP StorageWorks MSL2024, MSL4048, and MSL8096 Tape Libraries firmware release notes. Firmware version 4.60 (MSL2024), 6.90 (MSL4048), 9.
HP StorageWorks MSL2024, MSL4048, and MSL8096 Tape Libraries firmware release notes Firmware version 4.60 (MSL2024), 6.90 (MSL4048), 9.30 (MSL8096) Part number: AK378-96019 First edition: June 23, 2009
Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6
Alarm over IP IRIS Touch Home Installation Manual Version 1.0 ENGLISH Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 1. Introduction No more bulky batteries, just one sleek unit
MOBILE CALL GSM Alarm System User s Manual
MOBILE CALL GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Contents Function Introduction Alarm Host Diagram
Arduino Wifi shield And reciever. 5V adapter. Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the shield:
the following parts are needed to test the unit: Arduino UNO R3 Arduino Wifi shield And reciever 5V adapter Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the
Huawei E5220 Mobile Hotspot User Guide Contents
Huawei E5220 Mobile Hotspot User Guide Contents Getting to Know Your Mobile WiFi... 2 Application Scenarios... 2 Appearance... 2 Indicator... 2 SSID and Wireless Network Encryption Key... 2 Installing
IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited
(Rev. 1.0) China Aerospace Telecommunications Limited Contents 1. Introduction......3 2. Specifications...4 2.1 External Interface... 4 2.2 Status Indicator...... 5 2.3 Technical Parameters... 6 3. Device
MidiStream. UHF Wireless MIDI System Operating Manual
MidiStream UHF Wireless MIDI System Operating Manual Introduction Congratulations on your purchase of the MidiStream UHF wireless MIDI system. The MidiStream system is very easy to use, but please take
Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips
Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier Refer to the Lifestyle SA-2 & SA-3 Amplifier service manuals, part number 271720 for schematics, PCB layouts and parts lists. Preventative Repair Measures