Importance of Proper Sampling and Preservative Techniques Analysis dependent upon quality of sampling procedure Eliminate contamination Poor sampling
|
|
|
- Colleen Boone
- 9 years ago
- Views:
Transcription
1 Proper Sampling and Preservative Techniques for Wastewater Analysis By: Tom Horn Industrial Fluid Management Laboratory/Project Director LICENSES, STATE OF OHIO Class II Wastewater Analyst # Class II Operator, Wastewater Works # Guidelines for Consideration during Sample Collection NPDES Permit Requirements Type of Sample required by Permit Tools and/or Equipment Required 1
2 Importance of Proper Sampling and Preservative Techniques Analysis dependent upon quality of sampling procedure Eliminate contamination Poor sampling can hinder plant improvements or upgrades Sampling Definitions Grab Samples Composite Samples Preservatives Chain of Custody Clean sampling Techniques (Low Level Mercury Analysis) EPA Method 1631 Low Limit Mercury Clean Sample Techniques (18 min. video) Method 1669 Sample Collection Clean Hands/Dirty Hands Technique Field Blanks 2
3 What does your Permit Require? Guidelines for Consideration During Sample Collection Types of Parameters Samples to be Grab or Composite? 24-Hour Composite or 48-Hour Composite? Tools or Equipment needed to Fulfill Requirements Correct Sampling Container Sampling Dipper Sludge Judge Composite Sampler (complete or neat) Refrigerator 3
4 Importance of Proper Sampling and Preservative Techniques Analysis dependent upon quality of sampling Sample only as representative as sampling techniques Avoid contamination which leads to high or low results Poor sampling has been know to hinder plant improvements. Engineers use data presented for calculations in upgrades. If inaccurate sample collection data is used, municipality may invest in something that may not work. 4
5 SAMPLING DEFINITIONS GRAB SAMPLE Single sample collected at a specific spot over a short period of time. These samples represent a snapshot of space and time of a sampling area. D.O., ph, temperature, residual chlorine COMPOSITE SAMPLE Sample made up of several grab samples over an allotted time, normally in timed intervals or flow proportional. p BOD-5, TSS and NH3(N) are normally collected in this manner and are excellent in determining loadings from municipal and industrial plants. 5
6 PRESERVATIVE Chemical or physical technique of holding a sample. Enables accuracy to be continued over extended period of time. E.g. Cool to 4ºC, H2S04, HCl, Na0H CHAIN OF CUSTODY Relative to sample handling and submission. This form documents a sample s history from collection to analysis. This document should contain sample date, time, who collected the sample and anyone who handled the sample from collection to analysis. CONTAINERS, PRESERVATIVES AND HOLDING S 6
7 CBOD5/BOD5 CONTAINER PRESERVATIVE HOLDING P,G COOL 4ºC 48 HOURS TOTAL SUSPENDED SOLIDS CONTAINER PRESERVATIVE HOLDING P,G do 7 days AMMONIA CONTAINER PRESERVATIVE HOLDING P,G COOL 4ºC ph<2.0 S.U.@ 4ºC 24 HOURS 28 DAYS 7
8 H PHOSPHOROUS CONTAINER PRESERVATIVE HOLDING P,G RINSED W/ HCl ph<2.0 H2SO4, & COOL 4ºC 28 DAYS OIL & GREASE CONTAINER PRESERVATIVE HOLDING GLASS ONLY PTFE CAP ph<2.0 (H2SO4,HCL) & COOL 4ºC 28 DAYS METALS (Cd, Cr, Cu, Ni, Pb, Zn) Total or Total Recoverable CONTAINER PRESERVATIVE HOLDING P,G do 6 MONTHS 8
9 Cyanide, Free or Total CONTAINER PRESERVATIVE HOLDING P, G NaOH, ph days MERCURY* Method CONTAINER PRESERVATIVE HOLDING P,G ph<2.0 (HNO3) 28 DAYS *LOW LEVEL MERCURY Method 1631 Container and preservatives to be provided by analytical laboratory Sample must be accompanied by field blank, which is laboratory mercury free water and transferred to sample container at site of sample collection 9
10 CHROMIUM -6 CONTAINER PRESERVATIVE HOLDING P,G COOL 4ºC 24 HOURS FECAL COLIFORM / E. coli CONTAINER PRESERVATIVE HOLDING P,G (STERILE) COOL 4ºC, Na2S2O3 (if chlorinated effluent) 6 HOURS CLEAN SAMPLING TECHNIQUES FOR METALS Method sampling method of choice for low level mercury method Method Method detection level of 200ppt (0.2 ug/l) Method Method detection level of ppt 10
11 We have seen sampling techniques, weather conditions and other items interfere with low level mercury analysis. Items that interfere with low level mercury sampling Dental work and fillings can contaminate samples Car exhaust, industrial pollution and trains can cause contamination Rain and wind events should be considered Cigar / Cigarette smoke Rubber items like boots, gloves must be powder free nitrile BREAK! 20 minute USEPA video on low level mercury sample collection in ambient waters 11
12 Mercury Collection and Analysis in Ambient and Effluent Waters using EPA Method 1631 Sampling Equipment Office of Water SCC ppt Sampling Equipment Requirements Must be non-metallic and free from materials that contains metals, as described in Method 1669 All sampling equipment and sample containers must tb be precleaned in a laboratory or cleaning facility, as described in Method 1631 Gloves, storage bags, plastic wrap may be used new without cleaning unless equipment blank results pinpoint any of these materials as a contamination source If so, then supplies must also be precleaned or obtained from different supplier Protective Clothing Protective Coveralls, Smocks or Coats (where necessary) Disposable Tyvek, or equivalent Constructed of synthetic material to prevent possible contamination of samples by mercury adsorbed onto cotton or other clothing fibers Cost: $5 to $10 each Gloves Clean, disposable, powder-free latex, vinyl or polyethylene Sleeve protectors or shoulder-length length gloves may be used by clean hands person Cost: $15 to $20 per
13 Sample Collection Bottles Fluoropolymer (FEP, PFA) or Borosilicate Glass 125ml to 1L Fluoropolymer or fluoropolymer-lined lined screw cap New bottles cleaned prior to use Some vendors provide certified, precleaned glass bottles with various levels of cleanliness Recommend analysis of bottle blanks on a portion of bottle lot to verify cleanliness prior to sampling Used fluoropolymer bottles can be cleaned and reused Sample Collection Bottles (cont.) Store cleaned sample bottles with 0.1% HCl May empty weak acid solution and refill sample bottle with reagent water immediately prior to transport to the field Cost: 125ml to 1L Fluoropolymer: $40 to $120 each Glass: $2 to $5 each Sample Storage and Transport Storage Bags Clean, zip-lock, nonvented, colorless polyethylene Storage Cooler Clean, non-metallic, white interior Ice or refrigerant packs 13
14 Fiberglas s Pole Continuous-Flow Sampling Apparatus Te flo n Tubing C-Flex Tubing Peristaltic Pump Tubing Adaptor Clamp Ring Stand Cable Ties Filter Cartridge Teflo n We ig ht Continuous-Flow Sampling Apparatus (cont.) Used for effluent and ambient water sampling Peristaltic pump AC, 12VDC or internal battery, variable speed, single pump head Cole-Parmer, portable, Masterflex L/S with Easy Load pump head, or equivalent Cost: $800 to $1500 per pump system Continuous-Flow Sampling Apparatus (cont.) Tubing Fluoroploymer (FEP) 1/4 OD x 3/16 ID, in lengths as required to reach sampling point Cost: $1 to $2 per ft C-Flex, made w/ styrene-ethylene-butylene- silicone (SEBS) resin for use in peristaltic pump head Size 25, 5/16 OD x 3/16 ID, 1ft Cost: $1 to $2 per ft 14
15 Continuous-Flow Sampling Apparatus (cont.) Support Stand w/ Clamp Used to support end of outlet tubing Polyethylene, fiberglass or plastic-coated coated Cost: $80 to $120 Filter (dissolved metals) 0.45 um, 15 mm diameter or larger, tortuous- path capsule filter Gelman Supor # 12175, or equivalent Cost: $20 to $25 each Boat Sampling Metal-free (e.g. fiberglass) boat, along with wooden or fiberglass oars should be used For most situations, use of existing, available boat is acceptable Flat-bottom, Boston Whaler-type boat is preferred because sampling materials can be stored with reduced chance of tipping Gasoline- or diesel-fueled boat motors should be avoided because exhaust can be source of contamination Boat Sampling (cont.) Before first use, boat should be cleaned and stored in area that minimizes exposure to dust and atmospheric particles Immediately before use, boat should be washed with water at sampling site away from any sampling points to remove any dust or dirt accumulation Samples should be collected upstream & downwind of boat movement 15
16 Vendors Brand names, suppliers and part numbers in Method 1669 are for illustration only and no endorsement is implied. Equivalent performance may be achieved using apparatus and materials other than those specified in Method Vendors - cont. Some vendor sources include: - Cole-Parmer - Gelman Sciences - Fisher Scientific - Lab Safety Supply - Nalgene Labware - Bel-Art Scienceware Products - VWR Scientific Products -Associated Bag Co. -I-Chem - Eagle Picher 16
GUIDELINES FOR USE BY CLASS A LICENSEES IN MEETING SNP REQUIREMENTS JULY 1996
QUALITY ASSURANCE (QA) AND QUALITY CONTROL (QC) GUIDELINES FOR USE BY CLASS A LICENSEES IN MEETING SNP REQUIREMENTS AND FOR SUBMISSION OF A QA/QC PLAN JULY 1996 DEPARTMENT OF INDIAN AND NORTHERN AFFAIRS
This example of a completed sampling plan worksheet has been included to illustrate the information
APPENDIX B EXAMPLE OF A COMPLETED SAMPLING PLAN WORKSHEET This example of a completed sampling plan worksheet has been included to illustrate the information necessary to document a sampling program for
Appendix D lists the Field Services Standard Operating Procedures. Appendix E lists the Biological Monitoring Standard Operating Procedures.
Page 16 of 87 3.3 Sample Collection, Storage and Preservation Figure 3 details required containers, sample volumes, preservation techniques, and holding times for proper sample collection. A discussion
RESIDENTIAL TREATMENT SYSTEMS
EFFLUENT SAMPLING FOR RESIDENTIAL TREATMENT SYSTEMS For various reasons, many wastewater treatment systems periodically require effluent sampling and characterization. Whether sampling is done to verify
Water and Wastewater. Sample Collection and Analysis
Water and Wastewater Sample Collection and Analysis December 2011 Introduction Accurate testing of drinking water is crucial to maintaining the health and safety of Islanders who rely on this resource.
Dimethylglyoxime Method Method 10220 0.1 to 6.0 mg/l Ni TNTplus 856
Nickel DOC316.53.01065 Dimethylglyoxime Method Method 10220 0.1 to 6.0 mg/l Ni TNTplus 856 Scope and application: For water and wastewater. Test preparation Instrument-specific information Table 1 shows
APPLICATION OF ICP-MS TECHNOLOGY FOR TRACE METALS ANALYSIS
MR. TELLIARD: Our next speaker is Paula Hogg. Paula is currently a lab manager at Hampton Roads Sanitation District s Central Environmental Laboratory. We would like to also thank Hampton Roads for sending
Private Water Supplies Sampling Manual. A Field Guide
Private Water Supplies Sampling Manual A Field Guide Foreword This sampling manual details standard procedures for the collection, storage and transportation of samples at private water supplies in accordance
Color, True and Apparent
Color, True and Apparent DOC316.53.01037 Platinum-Cobalt Standard Method 1, 2, 3 Method 8025 15 to 500 color units Scope and application: For water, wastewater and seawater; equivalent to NCASI method
Color, True and Apparent
Color, True and Apparent DOC316.53.01037 Platinum-Cobalt Standard Method 1, 2, 3 Method 8025 15 to 500 color units 5 to 500 color units (low range technique) Scope and application: For water, wastewater
Direct Measurement Method Method 8157 0 to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor
Oxygen, Dissolved DOC316.53.01241 Direct Measurement Method Method 8157 0 to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor Scope and application: For water, wastewater and process
Nitrogen, Ammonia. Known Addition ISE Method 1 Method 10002 Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table
Nitrogen, Ammonia DOC316.53.01234 Known Addition ISE Method 1 Method 10002 Minimum of 0.8 mg/l NH 3 N Scope and application: For wastewater 2. Ammonia ISE 1 Adapted from the Standard Methods for the Examination
Sample Management SOP 2v8 Page 1 STANDARD OPERATING PROCEDURE NO. 2 SAMPLE MANAGEMENT REVISION LOG. Revision Number Description Date
Sample Management SOP 2v8 Page 1 STANDARD OPERATING PROCEDURE NO. 2 SAMPLE MANAGEMENT REVISION LOG Revision Number Description Date 2.0 Original SOP 2.1 Revisions by McLemore after field testing 1/3/04
1 Quality Assurance and Quality Control Project Plan
1 Quality Assurance and Quality Control Project Plan The purpose of this section is to describe the quality assurance/quality control program that will be used during the system specific field testing
Application Form 2E. Facilities Which Do Not Discharge Process Wastewater
United States Environmental Protection Agency Office of Water Enforcement and Permits Washington, DC 20460 EPA Form 3510-2E Revised August 1990 Permits Division Application Form 2E Facilities Which Do
LZV585 (B) The 1-cm path is aligned with the arrow on the adapter. 5940506
Chlorine, Total DOC316.53.01029 USEPA DPD Method 1 Method 10070 0.1 to 10.0 mg/l Cl 2 (HR) Powder Pillows Scope and application: For testing higher levels of total chlorine (free and combined) in drinking
Introduction. The following definitions may help you better understand the components of the data report.
Introduction This document is designed to help our clients understand the quality control requirements and limitations of data reporting. There are three sections to this document. The first section will
Suspended Solids: Unequal Results from Equal Methods
Suspended Solids: Unequal Results from Equal Methods By John Stone As of November 2003, 40 CFR, Part 136 lists five approved methods for determining Total Suspended Solids (Residue). Major differences
USEPA Electrode Method Method 8156
ph DOC316.53.01245 USEPA Electrode Method Method 8156 Scope and application: For drinking water 1, wastewater 2 and process water. 1 Based on Standard Method 4500-H+B, ASTM Method D1293-95 and USEPA Method
Brewery Wastewater: 2010 Water and Wastewater Conference. 11.02.2011 Page 1
Brewery Wastewater: Solutions for the Problem By Fred M. Scheer 2010 Water and Wastewater Conference Madison, WI 11.02.2011 Page 1 vr74 What We Will Discuss: Biochemical i Oxygen Demand (BOD): Where does
PERSONAL PROTECTIVE EQUIPMENT (PPE)
Page 1 of 6 (PPE) Personal protective equipment (PPE) is used to protect an individual from hazards associated with their work tasks or environment. Specific types of personal protective equipment include
Saudi Aramco Project Development
Saudi Aramco Project Development Wastewater Treatment Facilities Jeddah Refinery And Marine Area December 2007 Facilities Planning Dept. OBJECTIVE: Provide an overview of the complexities of developing
Making the Most of SáOá SM Services
MAINTENANCE PRODUCTS AND SERVICES Making the Most of SáOá SM Services With S O S Services, you don t just get test results, you get accurate analysis from the people who know your Cat equipment best. Your
Best Management Practices
for The City of Paso Robles is required to implement a Phase II Municipal Water Program in order to reduce or eliminate the pollutants that enter our waterways from both storm water and non-storm water
USEPA 1 FerroVer Method 2 Method 8008 0.02 to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls
Iron, Total DOC316.53.01053 USEPA 1 FerroVer Method 2 Method 8008 0.02 to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls Scope and application: For water, wastewater and seawater; digestion is required
DETERGENTS. Application Recommendations. Application/ Concerns. Recommended Detergent. Articles Cleaned/ Soil Removed. Cleaning Method.
Application/ Concerns Application Recommendations Articles Cleaned/ Soil Removed Glass, metal, plastic labware, ceramics, tissue culture, porcelain, clean rooms, animal cages, bioreactors, tubing, benches,
Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb
Document: AND Lead 100 7 2013 Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb July, 2013 Edition 1 ANDalyze, Inc., 2012. All rights reserved. Printed in USA. Table of Contents
Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls
Nitrate DOC316.53.01066 Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls Scope and application: For water, wastewater and seawater. Test preparation Instrument-specific
FerroVer Method 1 Method 10249 0.1 to 3.0, 1.0 to 30.0 and 10.0 to 300.0 mg/l Fe Powder Pillows
Iron, Total DOC316.53.01314 FerroVer Method 1 Method 10249 0.1 to 3.0, 1.0 to 30.0 and 10.0 to 300.0 mg/l Fe Powder Pillows Scope and application: For oil and gas field waters; digestion is required for
Environmental Technology March/April 1998
Treating Metal Finishing Wastewater Sultan I. Amer, Ph.D. AQUACHEM INC. Environmental Technology March/April 1998 Wastewater from metal finishing industries contains high concentrations of contaminants
Standard Operating Procedure for Total Kjeldahl Nitrogen (Lachat Method)
Standard Operating Procedure for Total Kjeldahl Nitrogen (Lachat Method) Grace Analytical Lab 536 South Clark Street 10th Floor Chicago, IL 60605 April 15, 1994 Revision 2 Standard Operating Procedure
Standard Operating Procedure for the Determination of Total and Total Dissolved Solids CCAL 13A.2
Standard Operating Procedure for the Determination of Total and Total Dissolved Solids CCAL 13A.2 Cooperative Chemical Analytical Laboratory College of Forestry Oregon State University 321 Richardson Hall
Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater
Document: AND Sol Env 08 2013 Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater Matrix specific sample preparation and testing methods for environmental waters
Particularly Hazardous Substances (PHS) Standard Operating Procedure (SOP)
Particularly Hazardous Substances (PHS) Standard Operating Procedure (SOP) Formaldehyde, formalin, paraformaldehyde solutions, and paraformaldehyde solids Principal Investigator: Room & Building #: Department:
ESS Method 130.1: General Auto Analyzer Procedures
ESS Method 130.1: General Auto Analyzer Procedures Environmental Sciences Section Inorganic Chemistry Unit Wisconsin State Lab of Hygiene 465 Henry Mall Madison, WI 53706 Revised October 1992 ESS Method
Standard Operating Procedure for Cleaning Nylon Filters Used for the Collection of PM 2. 5 Material
PM 2.5 Nylon Filter Cleaning Date: August 25,2009 Page I of8 Standard Operating Procedure for Cleaning Nylon Filters Used for the Collection of PM 2. 5 Material Environmental and Industrial Sciences Division
Lab PPE Guide Examples of Personal Protective Equipment
Lab PPE Guide Examples of Personal Protective Equipment 1140 South Paulina St. 245 (PSB) Chicago IL 60612 Phone: 312-413-3387 Fax: 312-413-3700 www.uic.edu/depts/envh This document is to be used as a supplement
Paper Chromatography: Separation and Identification of Five Metal Cations
Paper Chromatography: Separation and Identification of Five Metal Cations Objectives Known and unknown solutions of the metal ions Ag +, Fe 3+, Co 2+, Cu 2+ and Hg 2+ will be analyzed using paper chromatography.
Chlorine, Total. DPD Method 1 Method 10101 0.09 to 5.00 mg/l Cl 2 Test 'N Tube Vials. Test preparation. Instrument-specific information
Chlorine, Total DOC316.53.01028 DPD Method 1 Method 10101 0.09 to 5.00 mg/l Cl 2 Test 'N Tube Vials Scope and application: For testing higher levels of total (free plus combined) chlorine in drinking water,
Coating and Extraction of Honeycomb Denuders
QSM Approval: Coating and Extraction of Honeycomb Denuders 1 INTRODUCTION 1.1 The following procedures are used for the coating of honeycomb denuders with citric acid and sodium carbonate solutions, and
CLEAN ROOM TRAINING CLEAN ROOM AREAS
PREPARED FOR USE AT APL CLEAN ROOM AREAS Jon Coopersmith Scott Lange Rob Lee Syed Ali Modified for Homewood use with permission from authors 1 PURPOSE - EDUCATION What s important What to do What not to
Operator Quick Guide EC SENSOR
Operator Quick Guide EC SENSOR Revision G - 24/04/2008 General Information About This Guide The information in this guide has been carefully checked and is believed to be accurate. However, Hach Ultra
Microbiological Testing of the Sawyer Mini Filter. 16 December 2013. Summary
Microbiological Testing of the Sawyer Mini Filter 16 December 2013 Summary The Sawyer Mini Filter was tested for its ability to remove three microorganisms Raoultella terrigena, Bacillus subtilis, and
HS 1003 Part 2 HS 1003 Heavy Metals Test
HS 1003 Heavy Metals Test 1. Purpose This test method is used to analyse the heavy metal content in an aliquot portion of stabilised hot acetic acid extract by Atomic Absorption Spectroscopy (AAS). Note:
Clean Laboratory Techniques
Clean Laboratory Techniques Thursday November 18 th, 2010 Vanaja Sivakumar, Ph.D. Vice President, Inorganic Manufacturing Housekeeping Everyone in attendance will receive a copy of the slide deck The webinar
Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid
Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid Introduction Many metals react with acids to form hydrogen gas. In this experiment, you will use the reactions
Solids, Volatile Dissolved and Fixed Dissolved
, 8277 Solids, Volatile Dissolved and Fixed Dissolved Gravimetric Method 1 Scope and Application: For wastewater. 1 Adapted from Standard Methods for the Examination of Water and Wastewater DOC316.53.001206
ATTACHMENT 2. BMP Monitoring Plan Template
ATTACHMENT 2 BMP Monitoring Plan Template Project SPR - 335 Water Quality Facility Investigation Response to Modified Task 4: Development of BMP Monitoring Plan Template December 2002 i Table of Contents
Enhanced Organic Precursor Removals Using Aged Filter Media Page 1. Enhanced Organic Precursor Removals Using Aged Filter Media
Enhanced Organic Precursor Removals Using Aged Media Page 1 Enhanced Organic Precursor Removals Using Aged Media O b j e c t i v e s The main goals of this project was to evaluate the dissolved organic
World-Class Oil Sampling It is Possible
www.lubecontrol.com.au World-Class Oil Sampling It is Possible Lube Control Pty Ltd Providing lubrication solutions! Unit 5/53 Norfolk Rd, Marion, SA 5043 t: (08) 8298 5563 f: (08) 8298 6253 e: [email protected]
Best Management Practices For Dental Office Waste
Best Management Practices For Dental Office Waste Publication no. 06-04-007 Revised November 2015 Central Region 15 W Yakima Ave #200 Yakima WA 98902-3452 Northwest Region 3190 160 th Ave SE Bellevue WA
Phosphorus, Reactive (Orthophosphate)
Phosphorus, Reactive (Orthophosphate) DOC316.53.01113 Amino Acid Method 1 Method 8178 0.23 to 30.00 mg/l PO 4 Reagent Solution Scope and application: For water, wastewater and seawater. 1 Adapted from
Read all instructions carefully before completing the application. Applications must be typewritten.
Appendix A Tier 2 Application A This application is designed for use by laboratories seeking accreditation for samples analyzed for compliance with a National Pollution Discharge Elimination System (NPDES)
4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES
4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES Sl. No. Contents Preamble 4.1 Aim 4.2 Introduction 4.2.1 Environmental Significance 4.3 Principle 4.4 Materials Required 4.4.1 Apparatus Required 4.4.2 Chemicals
Agarose Gel Electrophoresis with Food Color- Teacher Guide
Page 1 of 7 Project Home Gateway to the Project Laboratory Activities What the Project can do in the classroom Biotechnology Resources Favorite resources online and in print Agarose Gel Electrophoresis
Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC
Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C. QUICK START GUIDE Fill with
Experiment 12- Classification of Matter Experiment
Experiment 12- Classification of Matter Experiment Matter can be classified into two groups: mixtures and pure substances. Mixtures are the most common form of matter and consist of mixtures of pure substances.
BHS CANDLE FILTER APPLICATIONS FOR CLARIFICATION / RECOVERY OF SOLIDS FROM CHEMICAL SLURRIES
FOR CLARIFICATION / RECOVERY OF SOLIDS FROM CHEMICAL SLURRIES TABLE OF CONTENTS 1. FINE CATALYST RECOVERY AT A REFINERY Pages 2 4 2. FINE SOLIDS REMOVAL & CLARIFICATION OF A SPECIALIZED ACIDIC SOLVENT
SPILLS & SPILL KITS. Spills -General Guidelines:
Spills -General Guidelines: If handled properly, a spill may be nothing more than a nuisance. If handled improperly, a spill can seriously disrupt your activities and the work of your colleagues. At worst,
STANDARD OPERATING INSTRUCTION. Safe Handling and Removal of Asbestos Cement Pipes Procedure
STANDARD OPERATING INSTRUCTION Safe Handling and Removal of Asbestos Cement Pipes Procedure 1 July 2012 Title System Reference Number Approved By Safe Handling and Removal of Asbestos Cement Pipes People
NPDES Permit No. IL0022071. Notice No. AAH:10120701.ajo. Public Notice Beginning Date: April 28, 2011. Public Notice Ending Date: May 30, 2011
Public Notice/Fact Sheet Issued By: Notice No. AAH:10120701.ajo Public Notice Beginning Date: April 28, 2011 Public Notice Ending Date: May 30, 2011 National Pollutant Discharge Elimination System (NPDES)
Improper storage of fuel on construction sites will increase the risk of water pollution that may occur as a result of leaks or spills.
WQ-10 Best Management Practice (BMP) Water Quality Protection Guideline Secondary Containment Design Standards Fuel Storage on Construction Sites According to the EPA, the majority of water pollution in
SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS
SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS Published in Water and Waste Digest membrane issue, November 2008 Miroslav Colic; Chief Scientist, Clean Water Technology
Longer lifetime for hydraulic oil
Longer lifetime for hydraulic oil In many applications hydraulic oils and lubricating oils are exchanged with new oil after only some thousand hours of operation. Changing the oil causes high costs and
Dry Ice Color Show Dry Ice Demonstrations
elearning 2009 Introduction Dry Ice Color Show Dry Ice Demonstrations Publication No. 95016 Add a small piece of solid carbon dioxide to a colored indicator solution and watch as the solution immediately
Guidance and Reporting Instructions on Temporary E-reporting for the MATS Rule
Guidance and Reporting Instructions on Temporary E-reporting for the MATS Rule As explained in the interim MATS e-reporting rule, which was signed by the Administrator on March 9, 2015, the EPA plans to
Best Management Practices for Mercury Waste Management in Dental Offices
Best Management Practices for Mercury Waste Management in Dental Offices Mercury Waste Best Management Practices (BMPs) for Dental Facilities are designed to comply with environmental regulations, prevent
ClikSTAR - Important facts about your new insulin delivery device.
ClikSTAR - Important facts about your new insulin delivery device. Instruction for Use ClikSTAR Insulin delivery device Before you start: Read these instructions and follow them completely each time you
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
NimbleGen DNA Methylation Microarrays and Services
NimbleGen DNA Methylation Microarrays and Services Sample Preparation Instructions Outline This protocol describes the process for preparing samples for NimbleGen DNA Methylation microarrays using the
WASTEWATER TREATMENT OBJECTIVES
WASTEWATER TREATMENT OBJECTIVES The student will do the following: 1. Define wastewater and list components of wastewater. 2. Describe the function of a wastewater treatment plant. 3. Create a wastewater
Neutralizing an Acid and a Base
Balancing Act Teacher Information Objectives In this activity, students neutralize a base with an acid. Students determine the point of neutralization of an acid mixed with a base while they: Recognize
HACH LANGE GmbH Willstätterstraße 11 40549 Düsseldorf
Supervision Certificate no. 10297 The establishment meets the requirements of 11 para 4 ElektroG (WEEE) as initial treatment plant for of waste electrical and electronic equipment in accordance with Annex
Standard Method for Sampling and Analysis of. of Chlorine Containing Bleaches. Soap Products
GUIDE SPECIFICATION FOR GENERAL CLEANING AND REMOVAL OF MOLD AND MILDEW ON EXTERIOR INSULATED AND FINISH SYSTEMS AND STUCCO DIVISION 07240 and DIVISION 09240 8/05 PART I: GENERAL 1.01 DESCRIPTION AND SCOPE
experiment5 Understanding and applying the concept of limiting reagents. Learning how to perform a vacuum filtration.
81 experiment5 LECTURE AND LAB SKILLS EMPHASIZED Synthesizing an organic substance. Understanding and applying the concept of limiting reagents. Determining percent yield. Learning how to perform a vacuum
New Jersey Sludge Sampling and Analytical Guidance Document
New Jersey Sludge Sampling and Analytical Guidance Document Prepared by: New Jersey Department of Environmental Protection Division of Water Quality Bureau of Pretreatment and Residuals January 2012 CONTENTS
QUALITY ASSURANCE / QUALITY CONTROL POLICY BREG SOIL AND WATER QUALITY LABORATORY UNIVERSITY OF DELAWARE
QUALITY ASSURANCE / QUALITY CONTROL POLICY BREG SOIL AND WATER QUALITY LABORATORY UNIVERSITY OF DELAWARE Department of Bioresources Engineering Rm 111 Worrilow Hall 531 S. College Ave. Newark, DE 19716-2140
S O SSM. Services. Cat. Management Guide. Accurate Analysis Improved Cost Control Optimized Performance
S O SSM Services Cat Management Guide Accurate Analysis Improved Cost Control Optimized Performance Contents S O S SM Services introduction... 3 Making the most of S O S Services...4-5 Good equipment health
Technical Cleaning Ó
Technical Cleaning JUSTIFICATION Cleaning of Data Centers and Communications Rooms should be performed by qualified personnel who will use techniques and equipment designed to clean without re-contaminating
Why is a Dental Amalgam. Reduction Program Being Implemented Now? PROGRAM OVERVIEW TOPICS
SAN FRANCISCO DENTAL AMALGAM REDUCTION PROGRAM How Dental Offices Can Comply with Local Regulations for Office Wastewater Discharged Into the Sewer System SEPTEMBER 2003 PROGRAM OVERVIEW TOPICS Why is
Introducing an All New Line of Cleaning Chemicals
www.alltemp.ca Introducing an All New Line of Cleaning Chemicals Coil Cleaners & Brighteners Metal Cleaning Detergents Ice Machine Cleaners Scale Removers Electronic Cell Cleaner Degreasing Solvent Leak
Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?
A Health and Safety Guideline for Your Workplace What is static electricity? What causes it? How is it hazardous? And, most importantly, how can it be controlled? All of these questions will be answered
Membrane Filtration Technology: Meeting Today s Water Treatment Challenges
Membrane Filtration Technology: Meeting Today s Water Treatment Challenges Growing global demand for clean water and increasing environmental concerns make membrane filtration the technology of choice
Line to Refrigerator Ice/Water Dispenser
Standard 18 Line to Refrigerator Ice/Water Dispenser Pump Module Bottled Water How The System Works The FLOJET Bottled Water Dispensing System was designed to pump water from a commercially available 5-gallon
DMR-QA Planning Guide 2015 DMR-QA 35: Plan for Success
DMR-QA Planning Guide 2015 DMR-QA 35: Plan for Success [ THE INDUSTRY STANDARD ] Your Partner In Defensible Data We understand that the art of our superior service is just as important as the science of
7. Chemical Waste Disposal Procedures
7. Chemical Waste Disposal Procedures Substances that Can and Cannot be Disposed of via Sink Drains or in Regular Solid Refuse Containers 1. It is prohibited to pour down a sink or floor drain, or place
Teacher Demo: Photosynthesis and Respiration: Complementary Processes
SNC1D/1P Sustainable Ecosystems/ Sustainable Ecosystems and Human Activity Teacher Demo: Photosynthesis and Respiration: Complementary Processes Topics photosynthesis and respiration gas tests for oxygen
This leaflet provides information on
This leaflet provides information on the fire and explosion hazards in the use of oxygen. It is for anyone who uses oxygen gas in cylinders. HSE8(rev2) Hazards from oxygen Oxygen gas in cylinders is used
THE ACTIVITY OF LACTASE
THE ACTIVITY OF LACTASE Lab VIS-8 From Juniata College Science in Motion Enzymes are protein molecules which act to catalyze the chemical reactions in living things. These chemical reactions make up the
Aerated Wastewater T r eatment System
GOVERNMENT Aerated Wastewater T r eatment System This Certificate of Accreditation is hereby issued by the Director-General of the NSW Ministry of Health pursuant to Clause 41(1) of the Local Government
WASTE WATER TREATMENT for surface treatment applications
WASTE WATER TREATMENT for surface treatment applications Effluent an important cost factor Effluent cannot be avoided Water and compound are essential for vibratory mass finishing. During the finishing