Chromatography-Columns & Accessories 01/2016

Size: px
Start display at page:

Download "Chromatography-Columns & Accessories 01/2016"

Transcription

1 Wöhlerstr. 2-6 D-5520 Mainz Tel / Fax / USt. Id.-Nr.: DE [email protected] 206 Chromatography-Columns & Accessories 0/206 Survey: Product Range page 2 HPLC-columns Price-Groups / EUR & Part-Numbers: HPLC-Columns HPLC-Columns New or Refill by MZ-Analysentechnik Available HPLC-Packings: µbondapak Hypersil Inertsil Kromasil LiChrosorb LiChrospher MZ-Aqua Perfect Nucleosil rbit PerfectChrom PerfectBond PerfectSil PerfectSil Target PerfectSil Target HD Superspher Waters Spherisorb Zorbax MZ-PAH - Separation of Polyaromatic Hydrocarbons MZ-PBM - Separation of Pesticides PerfectChrom - The Perfect Choice for Reliable Routine Analysis rbit - State-of-the-Art in Routine Analytics PerfectSil - High Quality by MZ-Analysentechnik PerfectSil Target - Excellent Performance + Peaksymmetry PerfectSil Target HD - Reversed Phase with Extended ph-stability PerfectSil High Quality for Bioseparation MZ-Aqua Perfect - C8 for up to 00 % Aqueous Media PerfectBond - State-of-the-Art-Replacement for classical Applications Kromasil -Special Columns - NEW! AmyCoat & CelluCoat HPLC-Guard Columns and Cartridges + Part-Numbers Accessories Syringes Rheodyne Parts & Acessories PEEK / Biocompatible Parts & Acessories Stainless Steel GPC-/SEC-Columns MZ-Gel SDplus LS - for Detection via Light Scattering MZ-Super FG - für Fluorinated Eluents MZ-Gel SDplus - für rganic Media

2 2 MZ-Analysentechnik: Developments and Trademarks PerfectSil Target PerfectChrom PerfectBond MZ-AquaPerfect MZ-PAH MZ-PBM MZ-Gel SDplus MZ Super-FG PerfectSil rbit Manufacturing of HPLC-Columns: Available Packings MZ-AquaPerfect PerfectSil Target Kromasil Superspher PerfectSil rbit LiChrosorb µbondapak PerfectChrom Hypersil LiChrospher Spherisorb PerfectBond Inertsil Nucleosil Zorbax SURVEY PRDUCT RANGE Product Range HPLC-Products - Sales & Service KRMASIL KRMASIL CHIRAL CELLUCAT AMYCAT SUMICHIRAL SUMIPAX CHIRALCEL CHIRALPAK NUCLESIL NUCLEDUR PRTECL PEEKSIL EVL CHIRAL AGP / -CBH / -HSA INERTSIL TITANSPHERE BIPTIC INERTSUSTAIN CHRMPAK CRWNPAK UNISN CADENZA Scherzo INTRADA CAPCELL PRTENAVI CERA- MSPHER SUCREBEAD ULTRN ES-VM / -PEPSIN Advanced Chromatography Technologies ACE AQ ACE C8-HL ACE CAPILLARY ACE C8-AR Extended Product Range - Sales nly Agilent Technologies Zorbax Accubond Evidex GC- Products LC-Accessories Accessories + Consumables LICHRSPHER LICHRSRB PURSPHER CHRMLITH ZIC -philic ZIC -HILIC CHRMEGABND AQUASEP FLURSEP (PERFLURPHENYL) TRIART PR C8 J'SPHERE BioPro YMC-PACK AMINEX BI-SIL BI-SILECT VYDAC EVEREST VISINHT VENTURE ALLTECH-PRDUKTE Restek GC-Columns... Hamilton LC-Product range LC-Syringes µbndapak ACQUITY XBRID- GE PRTEINPAK SYMMETRY BECKMANN ULTRASPHERE PAR- TISIL PARTISPHERE HYPERSIL GLD HYPERCARB SYNCRNIS BIBASIC BDS Supelcosil DISCVERY ASTEC ANTIBDIX PRTEMIX ZENIX SRT CARBMIX Perkin Elmer Brownlee Mitsubishi Chemical MCI Gel Diaion Sepabeads MZ-Analysentechnik delivers quick and reliably all kind of accessories for LC and GC. We handpick our suppliers for best quality at reasonable prices MZ-ANALYSENTECHNIK GMBH. Wöhlerstraße 2 6. D-5520 Mainz. Tel / Fax -20

3 3 Price List HPLC-Columns january st 206 Column Dimension Length x ID New C Refill D New Refill Price Groups (EUR) E New Refill F New Refill G New Refill H New Refill 50 x 2. mm 00 x 2. mm 25 x 2. mm x 2. mm 200 x 2. mm 250 x 2. mm x 3.0 mm 00 x 3.0 mm 25 x 3.0 mm x 3.0 mm 200 x 3.0 mm 250 x 3.0 mm x 4.0 mm 30 x 4.0 mm 40 x 4.0 mm x 4.0 mm 60 x 4.0 mm 75 x 4.0 mm x 4.0 mm 25 x 4.0 mm 50 x 4.0 mm x 4.0 mm 250 x 4.0 mm 300 x 4.0 mm x 4.6 mm 30 x 4.6 mm 40 x 4.6 mm x 4.6 mm 60 x 4.6 mm 75 x 4.6 mm x 4.6 mm 25 x 4.6 mm 50 x 4.6 mm x 4.6 mm 250 x 4.6 mm 300 x 4.6 mm Part-No. HPLC-Columns MZ four-digit Materialcode length in mm LEN IDØ ID in /0 mm Please check the following pages for materialcodes & price group of your desired packing media. Please inwuire for availability and details of refill service. The part-no. for ordering is a combination of materialcode and column dimension like in the following example: Example: PerfectSil 20 DS-2 5 µm (Materialcode 425 / Price group D) HPLC-Column 250 x 4.0 mm (Price: EUR 28.--) => Part-No.: MZ MZ-ANALYSENTECHNIK GMBH. Wöhlerstraße 2 6. D-5520 Mainz. Tel / Fax -20

4 4 Available HPLC-Packings Available HPLC-Packings January 206 In addition to HPLC-Columns for analytical purposes we pack columns in prep- and semiprep dimensions with 8-50 mm ID. All preparative columns are individually manufactured to meet the same quality standards as analytical columns as for each packing media we use an especially optimized packing protocol. Please ask for a quotation - we offer very competitive prices. Hypersil spherical 20 Å / 70 m 2 g - (BDS C8 30 Å) Thermo Scientific size ec carbon- USP code pricecontent group Hypersil SAS C 3 µm % L G Hypersil SAS C 5 µm % L E Hypersil SAS C 0 µm % L E Hypersil MS C8 3 µm % L G Hypersil MS C8 5 µm % L E Hypersil DS C8 3 µm + 0 % L 6043 G Hypersil DS C8 5 µm + 0 % L 6045 E Hypersil DS C8 0 µm + 0 % L 6040 E Hypersil CPS -CN 5 µm - 4 % L E Hypersil CPS -CN 0 µm - 4 % L E Hypersil APS -NH2 3 µm -.9 % L G Hypersil APS -NH2 5 µm -.9 % L E Hypersil APS-2 3 µm -.9 % L G Hypersil APS-2 5 µm -.9 % L E Hypersil APS-2 0 µm -.9 % L E Hypersil -Phenyl 5 µm - 5 % L 6075 E Hypersil BDS C8 5 µm + % L 695 G check our special brochure Thermo with the complete range of columns by Thermo Scientific LiChrosorb irregularly shaped 60 Å / 550 m 2 g - 00 Å / 300 m 2 g - Merck / EMD LiChrosorb Si 60 5 µm - - L3 005 E LiChrosorb Si 60 7 µm - - L3 007 E LiChrosorb Si 60 0 µm - - L3 000 E LiChrosorb Si 00 5 µm - - L E LiChrosorb Si 00 7 µm - - L E LiChrosorb Si 00 0 µm - - L E LiChrosorb RP-8 5 µm % L E LiChrosorb RP-8 7 µm % L E LiChrosorb RP-8 0 µm % L E LiChrosorb RP-8 5 µm - 7 % L 0055 E LiChrosorb RP-8 7 µm - 7 % L 0057 E LiChrosorb RP-8 0 µm - 7 % L 0050 E LiChrosorb-NH2 5 µm - 4 % L E LiChrosorb-NH2 7 µm - 4 % L E LiChrosorb-NH2 0 µm - 4 % L E LiChrosorb-CN 5 µm - 7 % L E LiChrosorb-CN 7 µm - 7 % L E LiChrosorb-CN 0 µm - 7 % L E LiChrosorb DIL 5 µm - 8 % L E LiChrosorb DIL 7 µm - 8 % L E LiChrosorb DIL 0 µm - 8 % L E µbondapak irregularly shaped 25 Å / 300 m 2 g - Waters size ec carbon- USP code pricecontent group µbondapak C8 0 µm % L 800 G Inertsil spherical 50 Å / 320 m 2 g - 00 Å / 450 m 2 g - Kromasil spherical 80 Å / 540 m 2 g - 0 Å / 320 m 2 g - GL-Sciences Inertsil 50 Å DS-2 5 µm + 8,5 % L 200 F Inertsil 00 Å DS-3 5 µm + 5 % L 2050 F Inertsil 50 Å C8 5 µm + 0,5 % L F Inertsil 50 Å C4 5 µm + 7,5 % L F Inertsil Phenyl 5 µm 0 % L 2040 F check our special brochure INERTSIL with the complete range of columns packed by GL Sciences Eka Nobel Kromasil 60 SIL 3.5 µm - - L F Kromasil 60 SIL 5 µm - - L3 050 E Kromasil 60 SIL 7 µm - - L E Kromasil 60 SIL 0 µm - - L E Kromasil 60 SIL 3 µm E Kromasil 60 SIL 6 µm E Kromasil 00 SIL 3.5 µm - - L3 050 F Kromasil 00 SIL 5 µm - - L3 05 E Kromasil 00 SIL 7 µm - - L3 052 E Kromasil 00 SIL 0 µm - - L3 053 E Kromasil 00 SIL 3 µm E Kromasil 00 SIL 6 µm E Kromasil 00 C 5 µm % L3 052 E Kromasil 00 C 7 µm % L E Kromasil 00 C 0 µm % L E Kromasil 00 C 3 µm % 0524 E Kromasil 00 C 6 µm % 0525 E Kromasil 00 C4 3.5 µm % L F Kromasil 00 C4 5 µm % L E Kromasil 00 C4 7 µm % L E Kromasil 00 C4 0 µm % L E Kromasil 00 C4 3 µm % 0534 E Kromasil 00 C4 6 µm % 0535 E Kromasil 00 C8 3.5 µm % L F Kromasil 00 C8 5 µm % L7 054 E Kromasil 00 C8 7 µm % L E Kromasil 00 C8 0 µm % L E Kromasil 00 C8 3 µm % 0544 E Kromasil 00 C8 6 µm % 0545 E Kromasil 00 C8 3.5 µm % L 0550 F Kromasil 00 C8 5 µm % L 055 E Kromasil 00 C8 7 µm % L 0552 E Kromasil 00 C8 0 µm % L 0553 E Kromasil 00 C8 3 µm % 0554 E Kromasil 00 C8 6 µm % 0555 E Kromasil 00 NH2 5 µm +.5 % L8 056 E Kromasil 00 NH2 7 µm +.5 % L E Kromasil 00 NH2 0 µm +.5 % L E Kromasil 00 NH2 3 µm +.5 % 0564 E Kromasil 00 NH2 6 µm +.5 % 0565 E

5 5 Available HPLC-Packings LiChrospher spherical 60 Å / 650 m 2 g - 00 Å / 420 m 2 g - Merck / EMD LiChrospher Si 60 5 µm - - L3 05 F LiChrospher Si 60 0 µm - - L3 00 F LiChrospher Si 00 5 µm - - L3 025 F LiChrospher Si 00 0 µm - - L3 020 F LiChrospher 00RP-8 5 µm % L7 035 F LiChrospher 00RP-8 0 µm % L7 030 F... 00RP-8 endc. 5 µm % L7 036 F... 00RP-8 endc. 0 µm % L7 03 F... 00RP-8 5 µm % L 045 F... 00RP-8 0 µm % L 040 F... 00RP-8 endc. 5 µm % L 046 F... 00RP-8 endc. 0 µm % L 04 F LiChrospher 00-NH2 5 µm % L8 055 F LiChrospher 00-NH2 0 µm % L8 050 F LiChrospher 00-CN 5 µm % L0 065 F LiChrospher 00-CN 0 µm % L0 060 F LiChrospher 00 DIL 5 µm % L F LiChrospher 00 DIL 0 µm % L F RP-Select B 5 µm +.5 % L7 085 F RP-Select B 0 µm +.5 % L7 080 F Nucleosil 00 spherical 00 Å / 350 m 2 g - Macherey-Nagel Nucleosil Si 00 3 µm - - L3 303 F Nucleosil Si 00 5 µm - - L3 305 E Nucleosil Si 00 7 µm - - L3 307 E Nucleosil Si 00 0 µm - - L3 300 E Nucleosil 00 C8 3 µm % L F Nucleosil 00 C8 5 µm % L E Nucleosil 00 C8 7 µm % L E Nucleosil 00 C8 0 µm % L E Nucleosil 00 C8 3 µm + 5 % L 3033 F Nucleosil 00 C8 5 µm + 5 % L 3035 E Nucleosil 00 C8 7 µm + 5 % L 3037 E Nucleosil 00 C8 0 µm + 5 % L 3030 E Nucleosil 00 C6H5 5 µm - 8 % L 3045 E Nucleosil 00 C6H5 7 µm - 8 % L 3047 E Nucleosil 00 -NH2 5 µm % L E Nucleosil 00 -NH2 0 µm % L E Nucleosil 00 -CN 5 µm - 5 % L E Nucleosil 00 -CN 0 µm - 5 % L E Nucleosil 00 -H 5 µm - 5 % L E Nucleosil 00 -H 7 µm - 5 % L E Nucleosil 00 -SA 5 µm % L G Nucleosil 00 -SA 0 µm % L G Nucleosil 00 -SB 5 µm - 0 % L G Nucleosil 00 -SB 0 µm - 0 % L G Nucleosil 300 spherical 300 Å / 00 m 2 g - Macherey-Nagel Nucleosil 300 C4 5 µm + 2 % L E Nucleosil 300 C4 7 µm + 2 % L E Nucleosil 300 C4 0 µm + 2 % L E Nucleosil 300 C8 5 µm - 3 % L E Nucleosil 300 C8 7 µm - 3 % L E Nucleosil 300 C8 0 µm - 3 % L E Nucleosil 300 C8 5 µm % L 3335 E Nucleosil 300 C8 7 µm % L 3337 E Nucleosil 300 C8 0 µm % L 3330 E Nucleosil 300 H 7 µm -.5 % L E MZ-Aqua Perfect spherical 20 Å / 30 m 2 g Å / 220 m 2 g - MZ-AT MZ-Aqua Perfect C8 3 µm + 5 % L 060 F MZ-Aqua Perfect C8 5 µm + 5 % L 062 D MZ-Aqua Perfect C8 7 µm + 5 % L 063 D MZ-Aqua Perfect C8 0 µm + 5 % L 064 D C8 3 µm + % L 0620 F C8 5 µm + % L 0622 D rbit 00 spherical 00 Å / 340 m 2 g - MZ-AT rbit 00 C8 3.5 µm + 9 % L 0902 E rbit 00 C8 4 µm + 9 % L 0904 E rbit 00 C8 5 µm + 9 % L 090 C rbit 00 C8 0 µm + 9 % L 0906 C rbit 00 C8 3.5 µm + 2 % L7 092 E rbit 00 C8 5 µm + 2 % L7 09 C rbit 00 C8 7 µm + 2 % L7 095 C rbit 00 C8 0 µm + 2 % L7 096 C rbit 00 C4 3.5 µm + 7 % L E rbit 00 C4 5 µm + 7 % L C rbit 00 C4 0 µm + 7 % L C rbit 00 CN 3.5 µm 6.5 % L E rbit 00 CN 5 µm 6.5 % L C rbit 00 Sil 3.5 µm - 0 % L3 093 E rbit 00 Sil 5 µm - 0 % L C rbit 00 Sil 0 µm - 0 % L C PerfectChrom MZ-AT spherical 60 Å / 550 m 2 g - 00 Å / 350 m 2 g - PerfectChrom 60 Sil 5 µm - - L3 575 C PerfectChrom 60 Sil 0 µm - - L3 577 C PerfectChrom 00 Sil 5 µm - - L3 525 C PerfectChrom 00 Sil 0 µm - - L3 527 C PerfectChrom 00 C8 3 µm + 7 % L 503 F PerfectChrom 00 C8 5 µm + 7 % L 505 C PerfectChrom 00 C8 0 µm + 7 % L 500 C PerfectChrom 00 C8 5 µm + 7 % 506 C PerfectChrom 00 C8L 5 µm % L 494 C PerfectChrom 00 C8L 0 µm % L 496 C PerfectChrom 00 C8M 5 µm + 2 % L 504 C PerfectChrom 00 C8 3 µm + 8 % L7 53 F PerfectChrom 00 C8 5 µm + 8 % L7 55 C PerfectChrom 00 C8 0 µm + 8 % L7 50 C PerfectChrom 00 C8M 5 µm + 6 % L7 54 C PerfectChrom 00 C 5 µm - 4 % L3 535 C PerfectChrom 00 C4 5 µm + 6 % L C PerfectChrom 00 C6 5 µm + 7 % L5 543 C PerfectChrom 00 CN 5 µm - 6 % L0 555 C PerfectChrom 00 CN 7 µm - 6 % L0 556 C PerfectChrom 00 CN 0 µm - 6 % L0 557 C PerfectChrom 00 CN-M 0 µm - L0 584 C PerfectChrom 00 Diol 5 µm - 5 % L C PerfectChrom 00 Diol 0 µm - 5 % L C PerfectChrom 00 NH2 5 µm % L8 55 C PerfectChrom 00 NH2 0 µm % L8 552 C Phenyl 3 µm -.5 % L 545 F Phenyl 5 µm -.5 % L 547 C Phenyl 0 µm -.5 % L 549 C Phenyl M 5 µm % L 53 C Phenyl M 0 µm % L 550 C Phenyl L 5 µm - 6 % L 532 C PerfectChrom 00 SAX 5 µm - L4 563 F PerfectChrom 00 SAX 0 µm - L4 565 F PerfectChrom 00 SCX 5 µm - L9 567 F PerfectChrom 00 SCX 0 µm - L9 569 F

6 6 Available HPLC-Packings PerfectBond PerfectSil MZ-AT spherical technical data & details: check page 6 PerfectBond DS-H 3 µm % L 94 F PerfectBond DS-H 5 µm % L 95 E PerfectBond DS-HD 3 µm % L 200 F PerfectBond DS-HD 5 µm % L 98 E PerfectBond C8 DS 5 µm % L 90 E PerfectBond C8 0 µm % L 0 E PerfectBond C8-HD 3 µm % L7 202 F PerfectBond C8-HD 5 µm % L7 204 E PerfectBond C8-H 3 µm % L7 93 F PerfectBond C8-H 5 µm % L7 92 E PerfectBond C8 5 µm % L7 08 E PerfectBond C 3 µm % L3 80 F PerfectBond C 5 µm % L3 82 E PerfectBond Ph 5 µm % L 220 E PerfectBond Ph-H 5 µm % L 222 E PerfectBond Si µm - - L C MZ-AT spherical 80Å/220m 2 g - 00Å/450m 2 g - 20Å/300m 2 g - 300Å/00 m 2 g - PerfectSil 80 DS-2 3 µm +.5 % L 663 F PerfectSil 80 DS-2 5 µm +.5 % L 660 D PerfectSil 00 Sil 5 µm - - L D PerfectSil 00 DS-3 3 µm % L 0708 F PerfectSil 00 DS-3 4 µm % L 0709 E PerfectSil 00 DS-3 5 µm % L 070 D PerfectSil 00 C8-3 5 µm % L7 075 D PerfectSil 00 Phenyl-3 5 µm % L 0735 D PerfectSil 00 NH2 5 µm % L D PerfectSil 00 CN-3 5 µm % L D PerfectSil 00 Diol 5 µm - L D PerfectSil 20 Sil 5 µm - - L3 40 D PerfectSil 20 Sil 0 µm - - L3 42 D PerfectSil 20 DS 3 µm % L 42 F PerfectSil 20 DS 5 µm % L 420 D PerfectSil 20 DS 7 µm % L 398 D PerfectSil 20 DS 0 µm % L 400 D PerfectSil 20 DS-L 3 µm % L 675 F PerfectSil 20 DS-L 5 µm % L 680 E PerfectSil 20 DS-2 3 µm % L 424 F PerfectSil 20 DS-2 5 µm % L 425 D PerfectSil 20 C 3 µm % L3 429 F PerfectSil 20 C 5 µm % L3 430 D PerfectSil 20 C4 3 µm % L F PerfectSil 20 C4 5 µm % L D PerfectSil 20 C8 3 µm +.0 % L7 44 F PerfectSil 20 C8 5 µm +.0 % L7 440 D PerfectSil 20 C8 0 µm +.0 % L7 442 D PerfectSil 20 CN 3 µm % L0 379 F PerfectSil 20 CN 5 µm % L0 380 D PerfectSil 20 Diol 0 µm L D PerfectSil 20 NH2 3 µm % L8 446 F PerfectSil 20 NH2 4 µm % L8 444 F PerfectSil 20 NH2 5 µm % L8 445 D PerfectSil 20 Phenyl 3 µm % L 447 F PerfectSil 20 Phenyl 4 µm % L 2446 F PerfectSil 20 Phenyl 5 µm % L 448 D PerfectSil 20 Phenyl-M 5 µm % L 449 D PerfectSil 20 Phenyl-L 5 µm % L 2448 D PerfectSil 200 DS 5 µm % L 48 E PerfectSil 300 Sil 5 µm - - L3 450 E PerfectSil 300 Sil 0 µm - - L3 840 D PerfectSil 300 Sil 5-20 µm D PerfectSil 300 DS C8 5 µm % L 455 E DS C8 0 µm % L 805 D DS C µm % 80 D PerfectSil 300 C4 5 µm % L E PerfectSil 300 C4 0 µm % L D PerfectSil 300 C µm % 835 D PerfectSil 300 C8 5 µm % L7 465 E PerfectSil 300 C8 0 µm % L7 820 D PerfectSil 300 C µm % 825 D PerfectSil 300 Diol 5 µm % L E PerfectSil 000 Sil 5 µm - - L3 475 D PerfectSil Target spherical 00 Å / 450 m 2 g - Spherisorb Zorbax Waters spherical 80 Å / 220 m 2 g - Spherisorb Si 5 µm - - L3 705 E Spherisorb Si 0 µm - - L3 700 E Spherisorb C 3 µm % L G Spherisorb C 5 µm % L E Spherisorb C 0 µm % L E Spherisorb C6 3 µm % L G Spherisorb C6 5 µm % L E Spherisorb C6 0 µm % L E Spherisorb C8 3 µm % L G Spherisorb C8 5 µm % L E Spherisorb C8 0 µm % L E Spherisorb DS- C8 3 µm +/- 6.2 % L 7053 G Spherisorb DS- C8 5 µm +/- 6.2 % L 7055 E Spherisorb DS- C8 0 µm +/- 6.2 % L 7050 E Spherisorb DS-2 C8 3 µm +.5 % L 7063 G Spherisorb DS-2 C8 5 µm +.5 % L 7065 E Spherisorb DS-2 C8 0 µm +.5 % L 7060 E Spherisorb -CN 3 µm - 3. % L G Spherisorb -CN 5 µm - 3. % L E Spherisorb -CN 0 µm - 3. % L E Spherisorb -NH2 3 µm -.9 % L G Spherisorb -NH2 5 µm -.9 % L E Spherisorb -Phenyl 3 µm % L 7093 G Spherisorb -Phenyl 5 µm % L 7095 E Spherisorb -Phenyl 0 µm % L 7090 E Superspher spherical 60 Å / 700 m 2 g - 00 Å / 350 m 2 g - MZ-AT PerfectSil Target Sil 00 3 µm - - L F PerfectSil Target Sil 00 5 µm - - L E PerfectSil Target DS-3 3 µm + 7 % L 0802 F PerfectSil Target DS-3 5 µm + 7 % L 080 E PerfectSil Target DS-3 0 µm + 7 % L 0806 D PerfectSil Target C8-3 3 µm + 9 % L7 082 F PerfectSil Target C8-3 5 µm + 9 % L7 08 E PerfectSil Target CN-3 5 µm - 7 % L0 088 E PerfectSil Target HD spherical 00 Å / 450 m 2 g - MZ-AT PerfectSil Target DS-3 HD 3 µm + 25 % L 0833 F PerfectSil Target DS-3 HD 5 µm + 25 % L 083 E PerfectSil Target DS-3 HD 0 µm + 25 % L 0830 E PerfectSil Target C8 HD 3 µm + 5 % L F PerfectSil Target C8 HD 5 µm + 5 % L E Merck / EMD Superspher Si 60 4 µm - - L3 024 G Superspher 60 RP-8 4 µm % L G Superspher 60 RP-8 (e) 4 µm + 3 % L G Superspher 00 RP-8 4 µm - 2 % L 0254 G RP-8 (e) 4 µm % L 0264 G RP-Select B 4 µm +.5 % L G Please check our brochure Merck for other MERCK HPLC-columns and accessories Agilent Technologies spherical 70 Å / 330 m 2 g - Zorbax Si 5 µm - - L3 045 G Zorbax TMS C 5 µm + 4 % L G Zorbax C8 5 µm + 2 % L G Zorbax C8 5 µm + 20 % L 0455 G riginal Zorbax HPLC-Columns available upon request.

7 Environmental Analysis check page 8 for guard cartridge holders 7 MZ-PAH: Separation of Polyaromatic Hydrocarbons Especially developed for the separation of Polyaromatic Hydrocarbons: MZ-PAH Columns by MZ-Analysentechnik. MZ-PAH-Columns are well-known for their outstanding performance: Excellent selectivity Guaranteed separation of 6 PAK (DIN F8) and 6 PAK (EPA Method 60) High efficiency: > 75,000 m - High reproducibility between column-to-column Long lifetime Refillable stainless steel column MZ-PAH 3 µm Length x ID Part-No. 50 x 3.0 mm MZ Refill-Service 50 x 3.0 mm MZ R Guard Cartridges 0x3.0 mm 5pc MZ00-VK x3.0 mm 5pc MZ00-VK Separation of 6 PAK / EPA-Method Column: MZ-PAH C8 5 µm 250 x 3.0 mm (LxID) MZ-PAH 5 µm Length x ID Part-No. 250 x 2. mm MZ x 3.0 mm MZ x 4.0 mm MZ Refill-Service 250 x 2. mm MZ-25002R* x 3.0 mm MZ R* x 4.0 mm MZ R* Guard Cartridges 0x2. mm 5pc MZ-VK x2. mm 5pc MZ-VK x3.0 mm 5pc MZ-VK x3.0 mm 5pc MZ-VK x4.0 mm 5pc MZ-VK x4.0 mm 5pc MZ-VK MZ-PBM: Separation of Pesticides Especially developed for the separation of nitrogen-containing pesticides: MZ-PBM - proven by being part of DIN F2. utstanding selectivity for nitrogen-containing pesticides High efficiency: > m - High reproducibility from batchto-batch thanks to a unique functionalization procedure Long lifetime Refillable stainless steel column Separation of 38 Pesticides Column: MZ-PBM C8 3 µm 250 x 3.0 mm (LxID) MZ-PBM 3 µm Length x ID Part-No. 250 x 2. mm MZ x 3.0 mm MZ x 4.0 mm MZ Refill-Service 250 x 2. mm MZ R x 3.0 mm MZ R x 4.0 mm MZ R Guard Cartridges 0x2. mm 5pc MZ22-VK x2. mm 5pc MZ22-VK x3.0 mm 5pc MZ22-VK x3.0 mm 5pc MZ22-VK x4.0 mm 5pc MZ22-VK x4.0 mm 5pc MZ22-VK

8 8 PerfectChrom The Perfect Choice for Reliable Routine Analytics Complex range of chemistries Each column tested individually Manufacturing process IS 900-certified Available as bulk media Polar Compounds Column: 20 min PerfectChrom 00 C8 50 x 4.6 mm ml/min Flow rate: Inj.volume: 0 µl Eluent: MeH:H 2 55:45 Temperatuer: 30 C Detection: 254 nm Analytes: uracil 2 acetophenone 3 methylbenzoate 4 benzene 5 toluene PerfectChrom Technical Data particle carbon Surface Pore- Price PerfectChrom... size ec contents USP area size Code group 60 Sil 5 µm - - L3 550 m 2 /g 60 Å 575 C 60 Sil 0 µm - - L3 550 m 2 /g 60 Å 577 C 00 Sil 5 µm - - L3 350 m 2 /g 00 Å 525 C 00 Sil 0 µm - - L3 350 m 2 /g 00 Å 527 C 00 C8 3 µm + 7 % L 350 m 2 /g 00 Å 503 F 00 C8 5 µm + 7 % L 350 m 2 /g 00 Å 505 C 00 C8 0 µm + 7 % L 350 m 2 /g 00 Å 500 C 00 C8 5 µm + 7 % 350 m 2 /g 00 Å 506 C 00 C8L 5 µm + 8,5 % L 350 m 2 /g 00 Å 494 C 00 C8L 0 µm + 8,5 % L 350 m 2 /g 00 Å 496 C 00 C8M 5 µm + 2 % L 350 m 2 /g 00 Å 504 C 00 C8 3 µm + 8 % L7 350 m 2 /g 00 Å 53 F 00 C8 5 µm + 8 % L7 350 m 2 /g 00 Å 55 C 00 C8 0 µm + 8 % L7 350 m 2 /g 00 Å 50 C 00 C8M 5 µm + 6 % L7 350 m 2 /g 00 Å 54 C 00 C 5 µm - 4 % L3 350 m 2 /g 00 Å 535 C 00 C4 5 µm + 6 % L m 2 /g 00 Å 539 C 00 C6 5 µm + 7 % L5 350 m 2 /g 00 Å 543 C 00 CN 5 µm - 6 % L0 350 m 2 /g 00 Å 555 C 00 CN 7 µm - 6 % L0 350 m 2 /g 00 Å 556 C 00 CN 0 µm - 6 % L0 350 m 2 /g 00 Å 557 C 00 CN-M 0 µm - L0 350 m 2 /g 00 Å 584 C 00 Diol 5 µm - 5 % L m 2 /g 00 Å 559 C 00 Diol 0 µm - 5 % L m 2 /g 00 Å 560 C 00 NH2 5 µm % L8 350 m 2 /g 00 Å 55 C 00 NH2 0 µm % L8 350 m 2 /g 00 Å 552 C 00 Phenyl 3 µm -.5 % L 350 m 2 /g 00 Å 545 C 00 Phenyl 5 µm -.5 % L 350 m 2 /g 00 Å 547 C 00 Phenyl 0 µm -.5 % L 350 m 2 /g 00 Å 549 C 00 Phenyl M 5 µm % L 350 m 2 /g 00 Å 53 C 00 Phenyl M 0 µm % L 350 m 2 /g 00 Å 550 C 00 Phenyl L 5 µm - 6 % L 350 m 2 /g 00 Å 532 C 00 SAX 5 µm - L4 350 m 2 /g 00 Å 563 F 00 SAX 0 µm - L4 350 m 2 /g 00 Å 565 F 00 SCX 5 µm - L9 350 m 2 /g 00 Å 567 F 00 SCX 0 µm - L9 350 m 2 /g 00 Å 569 F Refillable stainless steel column Best value for your money L x ID C D F [mm] New Refill New Refill New Refill 50 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Semiprep- and pre-scale available - please inquire. Part-No. MZ four-digit Materialcode length in mm LEN IDØ ID in /0 mm Example: PerfectChrom 00 C8 3 µm (503) 50 x 4.0 mm => Best.-Nr.: MZ Please inquire details for Refill-Service

9 9 ur completely new-developed product-line is based on extremely pure and ultra-stable porous silica with 00 Å mean pore size. The State-of-the-Art base silica is especially optimized for the requirements of today s routine analytics. is as well robust and shows an excellent chromatographic resolution plus it offers a high costefficiency - which may be further increased employing our Refill-service at very reasonable prices. State-of-the-Art for Routine Analytics Customers from routine analytics are thus now enabled to use the latest stationary phase technology without loss in suitability for daily use or a trade-off in chromatographic resolution. features excellent chromatographic separations with high efficiencies and symmetrical peak shape - while an excellent reproducibility from batch to batch and column to column is given. Like all HPLC-columns from MZ-Analysentechnik, HPLC-columns are manufactured under fully IS900-certified conditions and ship with a quality certificate including the original test chromatogram. can be packed in the full range of column dimensions (also available in semiprep and preparative scale) and is shipping with 3.5; 5 or 0 μm particle size and typical chemistries needed for standard separation tasks in routine analysis - see table below. L x ID 3.5 & 4 µm 5 & 0 µm [mm] New Refill New Refill Technical Data rbit Pore size 00 Å Pore volume 0,9 cm 3 /g Surface area (BET) 340 m 2 /g Morphology spherical Silica purity > 99,999 % Endcapping complete Carbon Contents CN: 6.5 %C C4: 7 %C C8: 2 %C C8: 9 %C Example: Part-no. MZ four-digit Materialcode length in mm LEN IDØ ID in /0 mm rbit C8 5 µm (090) 250 x 4.6 mm => Part-no.: MZ Please inquire details for Refill-Service Material-Codes rbit 00 C8 3.5 µm = 0902 rbit 00 C8 4 µm = 0904 rbit 00 C8 5 µm = 090 rbit 00 C8 0 µm = 0906 rbit 00 C8 3.5 µm = 092 rbit 00 C8 5 µm = 09 rbit 00 C8 7 µm = 093 rbit 00 C8 0 µm = 096 rbit 00 C4 3.5 µm = 0922 rbit 00 C4 5 µm = 092 rbit 00 C4 0 µm = 0926 rbit 00 CN 3.5 µm = 0875 rbit 00 CN 5 µm = 0875 rbit 00 Sil 3.5 µm = 093 rbit 00 Sil 5 µm = 0930 rbit 00 Sil 0 µm = x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Also available as semi-prep and prep - please inquire.

10 0 PerfectSil High Quality by MZ-Analysentechnik Steroids Column: PerfectSil DS-3 5 µm 50 x 4.6 mm Flow rate: ml/min Inj.volume: 0 µl Eluent: ACN :H 2 45:55 Temp.: 40 C Detection: 280 nm Analytes: beta-trenbolone 2 beta-estradiole 3 Diethylstilbestrole PerfectSil Well-established in various labs world-wide Highly reproducible Each column tested individually Available particle sizes: 3; 5 & 0 µm Highly pure silica skeleton > 99,999 % Large variety of available chemistries Available in 00 and 20 Å pore size Excellent chemical and mechanical stability Manufactured under fully IS 900-certified conditions Refill-service available Technical Data material particle pore surface pore carbon silica endcode size size area volume contents purity capped PerfectSil 00 Sil µm 00 Å 450 m 2 /g.05 ml/g PerfectSil 00 DS µm 00 Å 450 m 2 /g.05 ml/g 5.0 % PerfectSil 00 DS µm 00 Å 450 m 2 /g.05 ml/g 5.0 % PerfectSil 00 C µm 00 Å 450 m 2 /g.05 ml/g 9.0 % PerfectSil 00 Phenyl µm 00 Å 450 m 2 /g.05 ml/g 9.5 % PerfectSil 00 NH µm 00 Å 450 m 2 /g.05 ml/g 8.0 % PerfectSil 00 CN µm 00 Å 450 m 2 /g.05 ml/g 4.0 % PerfectSil 00 Diol µm 00 Å 450 m 2 /g.05 ml/g PerfectSil 20 Sil 40 5 µm 20 Å 300 m 2 /g.00 ml/g PerfectSil 20 Sil 42 0 µm 20 Å 300 m 2 /g.00 ml/g PerfectSil 20 DS 42 3 µm 20 Å 300 m 2 /g.00 ml/g 5.0 % PerfectSil 20 DS µm 20 Å 300 m 2 /g.00 ml/g 5.0 % PerfectSil 20 DS µm 20 Å 300 m 2 /g.00 ml/g 5.0 % PerfectSil 20 DS µm 20 Å 300 m 2 /g.00 ml/g 5.0 % PerfectSil 20 DS-L µm 20 Å 300 m 2 /g.00 ml/g 3.0 % PerfectSil 20 DS-L* µm 20 Å 300 m 2 /g.00 ml/g 3.0 % PerfectSil 20 DS µm 20 Å 300 m 2 /g.00 ml/g 7.0 % PerfectSil 20 DS µm 20 Å 300 m 2 /g.00 ml/g 7.0 % PerfectSil 20 C µm 20 Å 300 m 2 /g.00 ml/g 5.0 % PerfectSil 20 C µm 20 Å 300 m 2 /g.00 ml/g 5.0 % PerfectSil 20 C µm 20 Å 300 m 2 /g.00 ml/g 8.0 % PerfectSil 20 C µm 20 Å 300 m 2 /g.00 ml/g 8.0 % PerfectSil 20 C µm 20 Å 300 m 2 /g.00 ml/g.0 % PerfectSil 20 C µm 20 Å 300 m 2 /g.00 ml/g.0 % PerfectSil 20 C µm 20 Å 300 m 2 /g.00 ml/g.0 % PerfectSil 20 CN µm 20 Å 300 m 2 /g.00 ml/g 7.5 % PerfectSil 20 CN µm 20 Å 300 m 2 /g.00 ml/g 7.5 % PerfectSil 20 NH µm 20 Å 300 m 2 /g.00 ml/g 4.0 % PerfectSil 20 NH µm 20 Å 300 m 2 /g.00 ml/g 4.0 % PerfectSil 20 Phenyl µm 20 Å 300 m 2 /g.00 ml/g 9.5 % PerfectSil 20 Phenyl µm 20 Å 300 m 2 /g.00 ml/g 9.5 % PerfectSil 20 Phenyl-M µm 20 Å 300 m 2 /g.00 ml/g 6.0 % PerfectSil 20 Phenyl-L µm 20 Å 300 m 2 /g.00 ml/g 4.0 % Part-no. MZ four-digit Materialcode length in mm LEN IDØ ID in /0 mm Example: PerfectSil 20 DS 5 µm (42) HPLC-Column 250 x 4.6 mm => Part-no.: MZ Please inquire details for Refill-Service *please refer to PerfectSil µm for prices of PerfectSil DS-L 5 µm Dimension 3 µm 5/0 µm* L x ID New Refill New Refill 50 x 2. mm x 2. mm x 2. mm x 2. mm x 2. mm x 2. mm x 3.0 mm x 3.0 mm x 3.0 mm x 3.0 mm x 3.0 mm x 3.0 mm x 4.0 mm x 4.0 mm x 4.0 mm x 4.0 mm x 4.0 mm x 4.0 mm x 4.0 mm x 4.0 mm x 4.0 mm x 4.0 mm x 4.0 mm x 4.0 mm x 4.6 mm x 4.6 mm x 4.6 mm x 4.6 mm x 4.6 mm x 4.6 mm x 4.6 mm x 4.6 mm x 4.6 mm x 4.6 mm x 4.6 mm x 4.6 mm Also available as preparative HPLC-columns with ID 8-50 mm, please inquire.

11 PerfectSil 00 C8-3 Carboxylic Acids Column: Perfectsil C x 4.6 mm Fluw rate:.0 ml/min Eluent: Methanol / 20 mm Phosphate Buffer (ph 7.0) = 35 : 65 Temperature: 40 C Detection: 254 nm Inj.-Volume: µl fumaric acid 2 acrylic acid 3 itaconic acid 4 methacrylic acid PerfectSil 00 NH2 Tocopherol Column: PerfectSil 00 NH2 5 µm 250 x 4.6 mm Flow rate: ml/min Inj.volume: µl Eluent: ethylacetate : hexane 30:70 Temperature: 30 C Detection: 290 nm α-tocopherol 2 β-tocopherol 3 γ-tocopherol 4 δ-tocopherol PerfectSil 00 CN-3 Separation of Phenoles Normal-phase mode Column: PerfectSil CN x 4.6 mm Flow rate:.0 ml/min Eluent: hexane / ethanol = 90/0 Temperature: 40 C Detection: 280 nm Inj.volume: µl Analytes: diethylphthalate 2 4-nonylphenole 3 2,4-dichlorophenole 4 phenole 5 bisphenole-a PerfectSil 00 Si Fluocinolon Acetonide Column: PerfectSil 00 Si 5 µm 50 x 4.6 mm Flow rate: ml/min Inj.volume: 20 µl ( & 2,5 mg/ml) Eluent: CHCl 3(aq,saturated) : CH 3 H : CH 3 CH 000:5:0 Temperature: 30 C Detection: 254 nm Triamcinolon Acetonid 2 Fluocinolon Acetonid RP-Mode Column: PerfectSil CN x 4.6 mm Flow rate:.0 ml/min Eluent: acetonitrile / 20 mm phosphate-buffer (ph 3.0) = 45/55 Temperature: 40 C Detection: 280 nm Inj.volume: µl Analytes: phenole 2 diethylphthalate 3 bisphenole-a 4 2,4-dichlorophenole 5 4-nonylphenole PerfectSil 20 DS-2 Nitrosoaminderivates Column: PerfectSil 20 DS-2 5 µm 50 x 4.6 mm Flow rate: ml/min Eluent: CH 3 CN / 0 mm KH 2 P 4 60 / 40 Temperature: 40 C Detection: 230 nm N-Nitrosodimethylamine 2 N-Nitrosodiethylamine 3 N-Nitrosodi-n-propylamine 4 N-Nitrosodiphenylamine

12 2 PerfectSil Target Excellent Performance + Peak Symmetry = Aim Achieved Chemistries: Sil DS-3 C8-3 CN-3 Available particle size: 3 & 5 μm Highly pure silica: 99,999 % High mechanical & chemical resistibility Elaborated endcapping Excellent peak symmetry for basic compounds also Exquisite reproducibility PerfectSil Each column tested individually Particularly suitable for LC/MS Manufacturing process IS 900-certified Ships with HPLC-Column Technical Data Quality Certificate Pore size including authentic test-chromatogram Target DS-3 Sil C8-3 CN-3 DS-3 00 Å Pore volume. cm 3 /g Surface area (BET) 450 m 2 /g Carbon Contents 7 % Silica purity > % Total metal impurities < 5 ppm Amitryptilin PerfectSil Target DS-3 5 µm 200 x 4.6 mm Flow rate:.5 ml/min Inj.volume: 5 µl Eluent: methanol / 20 mm phosphate buffer ph=7.0 Temperature: 40 C Detection: 254 nm uracil 2 butylparabene 3 propanolol 4 dipropylphthalate 5 naphthalene 6 acenaphthene 7 amitryptiline min Part-no. MZ four-digit Materialcode length in mm LEN IDØ ID in /0 mm 7 Material-Code PerfectSil Target... Sil 00 3 µm = 0803 Sil 00 5 µm = 0800 DS-3 3 µm = 0802 DS-3 5 µm = 080 DS-3 0 µm = 0806 Example: PerfectSil Target DS-3 5 µm (080) 200 x 4.6 mm => Best.-Nr.: MZ Please inquire for details of Refill-Service C8-3 C8-3 CN-3 3 µm = µm = 08 5 µm = 088 L x ID 3 µm 5/0 µm* [mm] New Refill New Refill 50 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Also available as preparative HPLC-columns with ID 8-50 mm, please inquire.

13 3 PerfectSil Target HD Reversed-Phase with extended ph-stability PerfectSil Target Some applications in modern reversed-phase-hplc require extreme ph-conditions, causing most of today s silica-based stationary phase materials to show degradation. With those applications in mind, we developed PerfectSil Target HD to enable permanent operation at a ph-range from ph = 2-. Without any noticeable loss of performance or sign of degradation, PerfectSil Target HD is based upon the same highly pure silica skeleton as PerfectSil Target. PerfectSil Target HD is surface-shielded against basic and acidic degradation via application of a special post-treatment procedure after functionaliation with a virtually complete multiple-step endcapping procedure. The uniform reversed-phase chemistry in combination with its fully accessible 00 Å-pore-system, an optimized packing procedure and our state-of-theart stainless steel column hardware enables us to produce and deliver HPLC-columns at the highest level of quality. Elaborated endcapping Maximum shielding of silica-surface ph-range: ph = 2- Excellent chemical stability Extended usability range utstanding reproducibility from batch-to-batch and column-to-column Excellent peak symmetries for basic substances Enables to employ extremely steep gradients Vitamins Column: PerfectSil Target DS-3 HD 5 µm 50 x 4.6 mm Flow Rate:.0 ml/min Inj.volume: 5 µl Eluent: ACN : 0,2% H 3 P 4 + 5mM IPCC-06 / 0:90 Temperature: 40 C Detection: 20 nm Technical Data Target HD Pore size 00 Å Pore volume. cm 3 /g Specific Surface (BET) 450 m 2 /g Carbon Contents DS-3 HD: 25.0 % C8 HD: 5.0 % ph-stability ph 2- Endcapping complete Silica Purity > % Metal impurities < 5 ppm Analytes: Nicotinamide 2 Pantothenic acid 3 Pyridoxine 4 Riboflavinphosphate 5 Thiamine L x ID 3 µm 5/0 µm* [mm] New Refill New Refill 50 x x x x x x x x x x x x x x x x x x x x x x x x Part.-No. MZ four-digit Materialcode length in mm LEN IDØ ID in /0 mm Example: PerfectSil Target DS-3 HD 3 µm (0833) 50 x 4.0 mm => Best.-Nr.: MZ Please inquire for details of Refill-Service Material-Code PerfectSil Target... DS-3 HD 3 µm = 0833 DS-3 HD 5 µm = 083 DS-3 HD 0 µm = 0830 C8 HD 3 µm = 0843 C8 HD 5 µm = x x x x x x x x x x x x Also available as preparative HPLC-columns with ID 8-50 mm, please inquire.

14 4 PerfectSil 300 High Quality for Bioseparations State-of-the-art technology Ultra pure silica 99,999 % High-end surface chemistry Enables steep gradients Very low phase bleeding Suitable for LC/MS-applications High mechanical stability Excellent chemical stability Highly reproducible Refillable high-quality stainless-steel hardware Each column tested individually Available particle size: 5 & 0 μm 300 Å pore size for biopolymers Manufacturing process fully IS 900-certified Peptide Hormones Column: PerfectSil 300 C4 5 µm 250 x 4.6 mm Flow rate: ml/min Inj.volume: 0 µl Eluent: A: 0. % TFA/water B: 0.09 % TFA in ACN:water 90:0 (v/v) Gradient: 0 min: A:B 90:0 linear to 8 min: A:B 75:25 linear to 4 min: A:B 70:30 isocratic to 5-20 min recalibration A:B 90:0 Detection: 25 nm PerfectSil 300 Analytes: dead time marker / inj. 2 vasotocine 3 vasopressine 4 isotocine 5 oxytocine min 5 Technical Data code particle pore- surface pore carbon silica endsize size area volume contents purity capped PerfectSil 300 Sil µm 300 Å 00 m 2 /g.05 ml/g PerfectSil 300 Sil µm 300 Å 00 m 2 /g.05 ml/g PerfectSil 300 Sil µm 300 Å 00 m 2 /g.05 ml/g PerfectSil 300 DS C µm 300 Å 00 m 2 /g.05 ml/g 9.0 % PerfectSil 300 DS C µm 300 Å 00 m 2 /g.05 ml/g 9.0 % PerfectSil 300 DS C µm 300 Å 00 m 2 /g.05 ml/g 9.0 % PerfectSil 300 C µm 300 Å 00 m 2 /g.05 ml/g 3.0 % PerfectSil 300 C µm 300 Å 00 m 2 /g.05 ml/g 3.0 % PerfectSil 300 C µm 300 Å 00 m 2 /g.05 ml/g 3.0 % PerfectSil 300 C µm 300 Å 00 m 2 /g.05 ml/g 5.0 % PerfectSil 300 C µm 300 Å 00 m 2 /g.05 ml/g 5.0 % PerfectSil 300 C µm 300 Å 00 m 2 /g.05 ml/g 5.0 % PerfectSil 300 Diol µm 300 Å 00 m 2 /g.05 ml/g 5.0 % Part-no. MZ four-digit Materialcode length in mm LEN IDØ ID in /0 mm Example: PerfectSil 300 DS 5 µm (455) HPLC-column 250 x 4.6 mm => Part-no.: MZ Please inquire for details of Refill-Service L x ID 5 µm 0/5-20 µm* [mm] New Refill New Refill 50 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Also available as preparative HPLC-columns with ID 8-50 mm, please inquire.

15 MZ-Aqua Perfect C8 for up to 00% Aqueous Applications Elaborate C8-chemistry combined with new hydrophilic endcapping Compatible with up to 00% aqueous eluents Enables design of extremely steep gradients Short recalibration time Excellent reproducibility Highly pure & totally porous base silica Spherical particles with low polydispersity High chemical and mechanical resistibility Manufacturing process fully IS 900-certified Low backpressure Technical Data particle size 3/5/7/0 µm High durability morphology spherical pore size 20 / 200 Å surface area (BET) 30 / 220 m 2 /g carbon contents 5 / % C Water Soluble Vitamins Column: MZ-Aqua Perfect C8 3 µm 200 x 4.0 mm Flow rate:.25 ml/min Inj.volume: 0 µl Eluent: A: 0.05 M H 3 P 4 B: 0.05 M H 3 P 4 in H2:ACN 70:30 Gradient: 0-3 min isocratic 00 % A 3-6 min linear to 00 % B 6-2 min isocratic 00 % B 2-5 min recalibration 00 % A Temperature: RT Detection: 230 nm Analytes: thyamin (B) 2 ascorbic acid (C) 3 nicotinic acid (B) 4 nicotinamide (B3) 5 pyridoxal 6 pyridoxine (B6) 7 folic acid 8 cyanocobalmine (B2) 9 riboflavine (B2) min Applications tricyclic antidepressants theophylline water-soluble vitamins organic acids catecholamines caffeine all kind of C8 applications Part-No. MZ four-digit Materialcode length in mm LEN IDØ ID in /0 mm Example: MZ-AquaPerfect 5 µm (062) 250 x 4.6 mm => Part-no.: MZ Please inquire details for Refill-Service Materialcodes MZ-AquaPerfect C8 3 µm = 060 C8 5 µm = 062 C8 7 µm = 063 C8 0 µm = C8 3 µm = C8 5 µm = 0622 L x ID 3 µm 5/7/0 µm [mm] New Refill New Refill 50 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Also available as preparative HPLC-columns with ID 8-50 mm, please inquire.

16 6 PerfectBond State-of-the-Art- + Best Value-Replacement for Classical Applications ur recently introduced product-line PerfectBond is based on a series of selected state-of-the-art silica ( % purity), to provide modern replacements for traditional stationary phases. The PerfectBond product-range is continuously extended, enabling us to offer our customers reliable and cost-effective replacements for various well-known classical stationary phases. Classical stationary phases like μbondapak are still frequently used for many applications. Mainly because of their unique selectivity and retentivity - and despite disadvantages like high back-pressure Chlorophenoles Column: PerfectBond DS-HD 5 µm 250 x 4.0 mm Flow rate: ml/min Temperature: 30 C Detection: 280 nm Eluent: A: 50 % Methanol/H 2 + 0, % H 3 P 4 B: 00 % Methanol Gradient: 0-0 min isocratic 00 % A 0-20 min linear to 80 % B min isokratic 80 % B min equilibration 00 % A please check table and figures on page 3 for part-no. and price Analytes: 2-chlorophenole 2 4-chlorophenole 3 3-chlorophenole 4 2,6-dichlorophenole 5 2,3-dichlorophenole 6 2,5-dichlorophenole 7 2,4-dichlorophenole 8 3,4-dichlorophenole 9 3,5-dichlorophenole 0 2,3,6-trichlorophenole 2,3,4-trichlorophenole 2 2,4,6-trichlorophenole 3 2,4,5-trichlorophenole 4 2,3,5-trichlorophenole 5 2,3,5,6-tetrachlorophenole 6 2,3,4,5-tetrachlorophenole 7 pentachlorophenole resulting from the nature of irregularly shaped particle morphology. In case of μbondapak we offer PerfectBond C8 as excellent replacement: based on spherical and totally porous base silica, all chromatographic performance values are widely enhanced. PerfectBond is based upon an ultra pure, state-of-the-art-silica, which is absolutely spherical and functionalized under IS-900-certified conditions. We carefully select base silica, chemistry and carbon load to get an optimum match of the classical material. This enables us to deliver replacements for traditional stationary phases with the same retentivity and selectivity as the original material. PerfectBond -HPLC-columns feature lower backpressure and enhanced efficiency than the original. Replace your classic column with a PerfectBond - HPLC-Column and note the improved costefficiency reslting from longer column-lifetime and possibilities of refill-service. ur range of PerfectBond -HPLC-columns is continuously growing. Please inquire, if or when we can provide a state-ofthe-art replacement for your classical HPLC-column. Technical Data PerfectBond -Series particle size code price group pore size surface area chemistry carbon contens endcapping morphology silica purity PerfectBond DS-H 3 µm 94 F 20 Å 70 m 2 /g C8 0.0 % + spherical % PerfectBond DS-H 5 µm 95 E 20 Å 70 m 2 /g C8 0.0 % + spherical % PerfectBond DS-HD 3 µm 200 F 50 Å 320 m 2 /g C8 8.5 % + spherical % PerfectBond DS-HD 5 µm 98 E 50 Å 320 m 2 /g C8 8.5 % + spherical % PerfectBond C8 DS 5 µm 90 E 25 Å 300 m 2 /g C8 0.0 % + spherical % PerfectBond C8 0 µm 0 E 25 Å 300 m 2 /g C8 0.0 % + spherical % Replacement for µbondapak C8 0 µm PerfectBond C8-HD 3 µm 202 F 50 Å 320 m 2 /g C8 0.5 % + spherical % PerfectBond C8-HD 5 µm 204 E 50 Å 320 m 2 /g C8 0.5 % + spherical % PerfectBond C8-H 3 µm 93 F 20 Å 70 m 2 /g C8 6.5 % + spherical % PerfectBond C8-H 5 µm 92 E 20 Å 70 m 2 /g C8 6.5 % + spherical % PerfectBond C8 5 µm 08 E 25 Å 300 m 2 /g C8 7.0 % + spherical % PerfectBond C 3 µm 80 F 20 Å 70 m 2 /g C 5.0 % - spherical % PerfectBond C 5 µm 82 E 20 Å 70 m 2 /g C 5.0 % - spherical % PerfectBond Ph 5 µm 220 E 20 Å 200 m 2 /g Phenyl 6.0 % + spherical % PerfectBond Ph-H 5 µm 222 E 20 Å 70 m 2 /g Phenyl 5.0 % + spherical % PerfectBond Si µm 027 C 00 Å 320 m 2 /g Si - - spherical % Amino Acids / Peptides Column: PerfectBond C8 0 µm 300 x 4.0 mm Flow rate:.3 ml/min Inj.volume: 5 µl Eluent: 0,M Phosphate- Buffer ph 3,2 : ACN / 89: (v/v) Detection: Fluorescence 385/55 nm Analytes: Cysteine 2 Cysteinglycine 3 Homocysteine 4 Glutathione 5 N-Acetylcysteine Please ask us for the optimum Perfect- Bond -replacement for your classical stationary phase media: phone

17 7 High Performance Packings by EKA CHEMICALS AB, Schweden Best value for your money Kromasil is produced in multi-kilogram lots with excellent batch-to-batch reproducibility. Thanks to its outstanding performance combined with great price, Kromasil is first choice for the whole range of applications in modern HPLC. Kromasil HPLC-Columns 00 C C4 C8 C8 NH 2 60 SIL 00 SIL Semiprep & Prep 5/7 μm 0/3/6 μm 5/7 μm 0/3/6 μm Dimension New Refill New Refill New Refill New Refill 40 x 8 mm 25 x 8 mm 250 x 8 mm 250 x 0 mm 50 x 20 mm 250 x 20 mm please inquire please inquire Also available: columns with ID 30; 40 & 50 mm - please inquire Kromasil -Bulk Media 60 SIL & 00 SIL /g 0 g 50 g 00 g > 00 g 3.5 µm 5 µm 7 µm please inquire 0 µm 3 µm 6 µm C / C4 / C8 / C8 / NH2 / CN / Diol /g 0 g 50 g 00 g > 00 g 7 µm 0 µm 3 µm please inquire 6 µm ther chemistries and particle sizes available. Please ask for an individual quotation, if you need larger quantities of Kromasil -bulk media. Kromasil Chiral - CelluCoat & AmyCoat Kromasil Chiral is based upon an ultrastable silica skeleton. CelluCoat and AmyCoat are chirally-functionalized via covalently-bound polymeric layer of tris-(3,5-dimethylphenyl)carbonyl cellulose (CelluCoat ) respectively tris-(3,5- dimethylphenyl) carbonyl amylose (Amy- Coat ). The excellent chemical and mechanical stability of these recently developed materials enables operation at high flow rates in combination with high efficiencies. NEW! Preconditioned chiral columns CelluCoat RP and AmyCoat RP ready-to use for reversed-phase-applications. * HN NH HN HN NH HN * tris-(3,5-dimethylphenyl)carbamoyl amylose Kromasil Chiral Test-Kit 50 x 4.6 mm 3 µm 2, column each: AmyCoat AmyCoat RP CelluCoat CelluCoat RP 3 µm Length x ID 3 µm 5 µm 0 µm 25 µm 50 x 4.6 mm, x 4.6 mm,36.--, x 4.6 mm -,36.--,045.--, Chiral Bulk Media & Prep Scale available - please inquire.

18 8 Guard Columns GUARD CLUMNS Guard Cartridges Analytical / Narrowbore Part-No. price/ MZ-guard cartridges for analytical/narrow-bore HPLC-columns are available in dimensions with 3 different lengths and 4 different ID s. Please check below for suitable cartridge holders. MZ Guard Cartridges 5 pieces see below 6.-- ID: 2. mm, 3.0 mm, 4.0 mm and 4.6 mm four-digit length ID in Length: Materialcode 5 mm, 0 mm and in 20 mm mm /0 mm Part-Number for Cartridges (please check page 4ff for materialcodes): four-digit Materialcode LEN IDØ MZ VK LE ID length in mm ID in /0mm Cartridge Holder Analytical / Narrowbore Part-No. price/ suitable for MZ-Columns ID 2.; 3.0; 4.0 & 4.6 mm Example: guard cartridges (5 pcs.) Inertsil DS-2 5 μm (Materialcode 200) Dimension 20 x 4,0 mm (LxID) => Part-No.: MZ200-VK2040 cartridge holder integrated (suitable for VI cartridges of 20 and 0 mm length) cartridge holder integrated (suitable for VI cartridges of 5 mm length) cartridge holder free standing for standard fitting FG (suitable for cartridges of 20 mm length) cartridge holder free standing for standard fitting FG (suitable for cartridges of 0 mm length) cartridge holder free standing for standard fitting FG (suitable for cartridges of 5 mm length) SYRINGES HPLC-Syringes Exmire HPLC-High Quality Sampling Syringes smallest volume amount code price/ 5 µl 0. µl MSR µl 0.2 µl MSR µl 0.5 µl MSR µl.0 µl MSR µl 2.0 µl MSR µl 5.0 µl MSR µl 0.0 µl MSR

19 9 We offer the complete product range from RHEDYNE. The following list includes the most frequently requested parts. Please inquire for prices of parts not listed here. Part-No. Product Price/ RH rotor seal Vespel for 700/7000/ RH stator fü r 700/ RH rotor seal Tefzel for 700/7000/ RH RheBuild Kit for RH702 sample loop stainless steel 0 μl RH7022 sample loop stainless steel 20 μl RH7023 sample loop stainless steel 50 μl RH7024 sample loop stainless steel 00 μl RH7025 sample loop stainless steel 200 μl RH7026 sample loop stainless steel 500 μl RH7027 sample loop stainless steel ml RH7028 sample loop stainless steel 2 ml 2.-- RH7029 sample loop stainless steel 5 ml RH7000 switching valve RH way switching valve RH positions switching valve RH725 sample injector, RH7725 sample injector with MBB, front-loading, follow-up of 725 RH7725i sample injector with position sensing switch and MBB,77.-- RH825 syringe loading injector, front-loading for micro-hplc RH rotor seal for 825/ RH RheBuilt Kit for 7520/ RH3725i sample injector PEEK, front-loading, preparative scale RH3725i-038 sample injector stainless steel,69.-- front-loading, preparative scale RH900 sample injection valve PEEK, rear-loading, for analytical HPLC RH9725 sample injector PEEK with MBB (ex-925), front-loading, for analytical HPLC RH sample loop PEEK 5 μl RH sample loop PEEK 0 μl RH sample loop PEEK 20 μl RH sample loop PEEK 50 μl RH sample loop PEEK 00 μl RH sample loop PEEK 200 μl RH sample loop PEEK 500 μl RH sample loop PEEK ml RH sample loop PEEK 2 ml RH µm column inlet filter, ID 3.0 mm 2.-- RH Replacement filter discs for RH7335 5/pk 40.--

20 20 Tools & Accessories - PEEK / Biocompatible HPLC-ACCESSRIES Part-No. Product Price/ AP033 PEEK-tubing AD /6 x 0.3 mm ID 3 m AP037 AD /6 x 0.7 mm ID 3 m AP0325 AD /6 x 0.25 mm ID 3 m AP0350 AD /6 x 0.50 mm ID 3 m AP0375 AD /6 x 0.75 mm ID 3 m AP053 PEEK-tubings kit AD /6 x 0.3 mm ID 50; 00; 200 mm AP057 - pre-cut - AD /6 x 0.7 mm ID 50; 00; 200 mm AP pieces of each length AD /6 x 0.25 mm ID 50; 00; 200 mm AP0550 AD /6 x 0.50 mm ID 50; 00; 200 mm AP0575 AD /6 x 0.75 mm ID 50; 00; 200 mm AP500 fingertight-fittings PEEK 0 pcs coupler universal fingertight PEEK AP mm ID ( red ) piece 9.-- AP mm ID ( yellow ) piece 9.-- AP mm ID ( blue ) / universal piece 9.-- AP mm ID ( orange ) piece 9.-- AP520 union PEEK /6 set 8.-- (incl. 2 fingertight-fittings) AR Clean-Cut for cutting polymeric tubings AR Replacement blade for Clean-Cut AR Guillotine-Cutter AR Replacement blade for Guillotine-Cutter AP530 tee-piece PEEK /6 set (incl. 3 fingertight-fittings) AP Last-drop mobile phase-filter with 2,5 µm PTFE- Fritt AP540 cross PEEK /6 set (incl. 4 fingertight-fittings) AP560 plug PEEK /6 piece 4.50 fingertight elbow for PEEK-tubing AP AN550 plug Nylon /6 0 pieces 7.-- AN pieces AP

21 2 Tools & Accessories - Stainless Steel Part-No. Product Price/ AS030 Stainless Steel tubing AD /6 x 0.3 mm ID 3 m AS038 AD /6 x 0.8 mm ID 3 m 8.-- AS0325 AD /6 x 0.25 mm ID 3 m 8.-- AS0350 AD /6 x 0.50 mm ID 3 m 8.-- AS0370 AD /6 x 0.75 mm ID 3 m 8.-- AS030 AD /6 x.00 mm ID 3 m 8.-- AS050 Stainless Steel tubing AD /6 x 0.3 mm ID 50 mm 2.50 AS034 - pre-cut - AD /6 x 0.3 mm ID 00 mm 4.40 AS020 AD /6 x 0.3 mm ID 200 mm 5.50 AS0525 AD /6 x 0.25 mm ID 50 mm 2.50 AS025 AD /6 x 0.25 mm ID 00 mm 4.40 AS0225 AD /6 x 0.25 mm ID 200 mm 5.50 AS0550 AD /6 x 0.50 mm ID 50 mm 2.50 AS050 AD /6 x 0.50 mm ID 00 mm 4.40 AS0250 AD /6 x 0.50 mm ID 200 mm 5.50 AS0570 AD /6 x 0.75 mm ID 50 mm 2.50 AS070 AD /6 x 0.75 mm ID 00 mm 4.40 AS0270 AD /6 x 0.75 mm ID 200 mm 5.50 AS00 stainless steel ferrules /6 0 pcs 9.-- AS00 stainless steel ferrules /6 00 pcs AR0 stainless steel ferrules /6 Rheodyne 0 pcs 9.-- AS200 fitting screws stainless steel short 0 pcs AS20 fitting screws stainless steel long 0 pcs AS220 fitting screws stainless steel extra large 0 pcs AS stainless steel tubing cutter AS pliers for stainless steel tubings AS Last-drop mobile phase-filter with 2.0 μm stainless steel frit AR Rheotool HPLC-ACCESSRIES AS330 plug stainless steel /6 piece 6.-- AS300 ZDV-union stainless steel /6 piece AC EasyFlange Kit AS30 tee-piece stainless steel /6 piece AS320 cross stainless steel /6 piece Accessories for HPLC-Columns AS00 sieve (glass fibre) analytical 0 pcs 5.-- AS05 PTFE sealing gasket 25 pcs 2.-- AS00 sieve (metal) analytical 5 μm 0 pcs 8.-- AS005 sieve (metal) analytical 3 μm 0 pcs 9.-- AS020 sieve sandwich 3 μm for column end 2.; 3.0; 4.0 & 4.6 mm ID Set 3.-- (2 metal sieves. 3 glass fibre sieves. sealing gasket) AS02 sieve sandwich 5 μm Set 3.-- AC EasyFlange Combi-Kit.

22 22 MZ-Gel SD LS - for Detection via Light Scattering MZ-Gel SDplus LS is a proprietary development of MZ-Analysentechnik based on highly-crosslinked and totally porous high-performance styrene-divinyl-benzene copolymer. It is derived from MZ-Gel SDplus as base material by a special post-treatment to meet the special requirements of detection via light-scattering. Therefore MZ- Gel SDplus LS features an extremely low phase-bleeding plus the extraordinary capabilities like the HPLC-like separation efficiency of the well-known original material. Molecular Mass Range & Exclusion Limit Porosity Molecular Mass Range Exclusion Limit 50 Å < 2,000 3, Å < 3,000 5, Å < 20,000 20,000 0e3 Å,000-40,000 70,000 0e4 Å 4, , ,000 0e5 Å 0,000-2,000,000 4,000,000 0e6 Å 200,000-0,000,000 > 0,000,000 Linear,000 -,000,000 > 2,000,000 Materialcodes MZ-Gel SDplus LS Porosity 3 µm 5 µm 0 µm 50 Å Å Å ,000 Å Å Å Å Linear Analytical 8 mm ID price/ Length x ID Particle Size Porosity New Refill 300 x 8 mm 3 µm 50 Å; 00 Å; 500 Å; 0 3 Å,22.--, µm 50 Å; 00 Å; 500 Å; 0 3 Å; 0 4 Å; 0 5 Å; 0 6 Å µm linear, µm 50 Å; 00 Å; 500 Å; 0 3 Å; 0 4 Å; 0 5 Å; 0 6 Å µm linear x 8 mm 5 µm 50 Å; 00 Å; 500 Å; 0 3 Å; 0 4 Å; 0 5 Å; 0 6 Å,404.--, µm linear,63.--, µm 50 Å; 00 Å; 500 Å; 0 3 Å; 0 4 Å; 0 5 Å; 0 6 Å, µm linear,259.--, x 8 mm 5 µm all porosities + linear µm all porosities + linear Part-No. MZ four-digit Materialcode length in mm LEN IDØ ID in /0 mm Microbore 250 x 3 mm 5 µm all porosities + linear x 3 mm 5 µm all porosities + linear x 2 mm 5 µm all porosities + linear x 2 mm 5 µm all porosities + linear Example: MZ-Gel SDplus LS 00 VKLE Å 5 µm ID (506); SEC-Column four-digit 300 x 8.0 mm length ID in Materialcode in mm /0mm => Part-no.: MZ Please inquire details for Refill-Service Narrowbore 4.6 mm ID (saving up to 70 % of solvent) 300 x 4,6 mm 3 µm 50 Å; 00 Å; 500 Å; 0 3 Å,25.--, µm 50 Å; 00 Å; 500 Å; 0 3 Å; 0 4 Å; 0 5 Å; 0 6 Å µm linear x 4,6 mm 3 µm 50 Å; 00 Å; 500 Å; 0 3 Å µm all porosities + linear µm all porosities + linear all prices in EUR excl. VAT. MZ-ANALYSENTECHNIK GMBH. Wöhlerstraße 2 6. D-5520 Mainz. Tel / Fax -20

23 23 MZ Super-FG: SEC-Columns for Fluorinated Eluents MZ Super-FG SEC-Columns are based on especially modified Silica. They are the ideal media for separations performed in fluorinated mobile phases like TFE or HFIP. Technical Data MZ-Gel Super FG Particle Size 7 µm Pressue Stability max. 300 bar Max. Flow Rate: Analytical 8 mm ID 3 ml/min Preparative 20 mm ID 20 ml/min Temperature Stability max. 80 C ph-stability 2 9 Pore Volume ml/g Porosity Molecular Mass Range Exclusion Limit Linear MZ-Super FG-columns are available as four different porosities, plus linear mix. The table shows the molecular mass range and the exclusion limit. Prices and rdering information Analytical Price/ New Refill 300 x 8 mm 7 µm all porosities µm linear x 8 mm 7 µm all porosities, µm linear,222.--, x 8 mm 7 µm all porosities Preparative 300 x 20 mm 7 µm all porosities 2,07.--, µm linear 2, , x 20 mm 7 µm all porosities + linear Part-No. MZ four-digit Materialcode length in mm LEN IDØ ID in /0 mm Example: MZ Super-FG linear 7 µm (9000); SEC-Column 300 x 8.0 mm => Best.-Nr.: MZ Please inquire details for Refill-Service Porosity Code , , Linear 9000 MZ VKLE ID. MZ-ANALYSENTECHNIK four-digit GMBH length ID. Wöhlerstraße in 2 6. D-5520 Mainz. Tel / Fax -20 Materialcode in mm /0mm

24 24 MZ-Gel SD - for rganic Media MZ-Gel SDplus by MZ-Analysentechnik is a high-performance styrene-/divinylbenzene-copolymer, tightly classed with a narrow pore size distribution. The excellent quality of this highly cross linked packing media enables us to pack GPC-columns with both a long lifetime and extraordinary high column efficiencies. For example: columns with 3 μm particle size are delivered with guaranteed theoretical plate-numbers: > 00,000 m - Analytical 8 mm ID Price/ Length x ID Particle Size Porosity New Refill 300 x 8 mm 3 µm 50 Å; 00 Å; 500 Å; 0 3 Å, µm 50 Å; 00 Å; 500 Å; 0 3 Å; 0 4 Å; 0 5 Å; 0 6 Å µm linear µm 50 Å; 00 Å; 500 Å; 0 3 Å; 0 4 Å; 0 5 Å; 0 6 Å µm linear x 8 mm 5 µm 50 Å; 00 Å; 500 Å; 0 3 Å; 0 4 Å; 0 5 Å; 0 6 Å,279.--, µm linear,468.--, µm 50 Å; 00 Å; 500 Å; 0 3 Å; 0 4 Å; 0 5 Å; 0 6 Å, µm linear, x 8 mm 5 µm all porosities + linear µm all porosities + linear Microbore 250 x 3 mm 5 µm all porosities + linear x 3 mm 5 µm all porosities + linear x 2 mm 5 µm all porosities + linear x 2 mm 5 µm all porosities + linear Codes MZ-Gel SDplus Porosity 3 µm 5 µm 0 µm 50 Å Å Å ,000 Å Å Å Å Linear Narrowbore 4.6 mm ID (saving up to 70 % of solvent) 300 x 4.6 mm 3 µm 50 Å; 00 Å; 500 Å; 0 3 Å, µm 50 Å; 00 Å; 500 Å; 0 3 Å; 0 4 Å; 0 5 Å; 0 6 Å µm linear x 4.6 mm 3 µm 50 Å; 00 Å; 500 Å; 0 3 Å µm all porosities + linear µm all porosities + linear Preparative 20 mm ID 300 x 20 mm 0 µm 50 Å; 00 Å; 500 Å; 0 3 Å; 0 4 Å; 0 5 Å; 0 6 Å 2,037.--, µm linear 2, , x 20 mm 0 µm all porosities + linear Analytical Narrowbore Microbore Part-No. MZ four-digit Materialcode length in mm LEN IDØ ID in /0 mm 8 mm 4.6 mm 3.0 mm 2.0 mm.6 mm Example: MZ-Gel SDplus 00 Å 5 µm (505); MZ VKLE ID SEC-Column 300 x 8.0 mm => Part.-No.: four-digit MZ length ID in Materialcode in mm Please inquire details for Refill-Service /0mm

Unique Bonding Chemistry

Unique Bonding Chemistry columns Acclaim HPLC Columns Reversed-phase silica columns for pharmaceutical, nutraceutical, environmental, food, and life science applications in HPLC. High hydrophobicity, low polarity phases LC/MS

More information

Strength in Technology HPLC COLUMNS. Product Guide

Strength in Technology HPLC COLUMNS. Product Guide Strength in Technology HPLC COLUMNS Product Guide [ m V ] Cefadroxil 3 5 0 3 0 0 UniverSil C18 250x4.6mm 5µm Cefachlor Surface Area - 175m 2 /g 2 5 0 Pore Size - 140Å Voltage 2 0 0 Cefradine % Carbon -

More information

USP L Phase Listing. Octadecyl silane chemically bonded to porous silica or ceramic micro-particles, 3 to 10 μm in diameter, or a monolithic rod.

USP L Phase Listing. Octadecyl silane chemically bonded to porous silica or ceramic micro-particles, 3 to 10 μm in diameter, or a monolithic rod. L1 USP L Phase Listing Octadecyl silane chemically bonded to porous silica or ceramic micro-particles, 3 to 10 μm in diameter, or a monolithic rod. Eurosil-Bioselect 300 C18 * Eurospher 100 C18 * Hipak

More information

Thermo Scientific Syncronis HPLC Columns. Technical Manual

Thermo Scientific Syncronis HPLC Columns. Technical Manual Thermo Scientific Syncronis HPLC Columns Technical Manual Thermo Scientific Syncronis HPLC Columns When developing a new method, one of the most important goals for the chromatographer is to achieve a

More information

Bulk Materials for Preparative and Process Chromatography

Bulk Materials for Preparative and Process Chromatography Bulk Materials for Preparative and Process Chromatography Silica Based HPLC Bulk Media Characteristics Available in both reversed and normal phases High chemical stability for low leaching High loading

More information

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep Guide to Reverse Phase SpinColumns Chromatography for Sample Prep www.harvardapparatus.com Contents Introduction...2-3 Modes of Separation...4-6 Spin Column Efficiency...7-8 Fast Protein Analysis...9 Specifications...10

More information

SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0) 1234 758322. [email protected].

SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0) 1234 758322. i.chianella.1998@cranfield.ac. SPE and HPLC Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0) 1234 758322 [email protected] Solid-Phase Extraction- SPE Simple, fast and efficient sample preparation

More information

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation Application Note Determination of Nitrite and Nitrate in Fruit Juices by UV Detection Category Food Matrix Fruit Juice Method HPLC Keywords Ion pair chromatography, fruit juice, inorganic anions AZURA

More information

Materials for Pharmaceutical Manufacturing

Materials for Pharmaceutical Manufacturing Materials for Pharmaceutical Manufacturing GRACE WHITEPAPER Vydac 150HC Purification Media Greater Loading Capacity and Resolution for Improved Productivity in Peptide Purification Technical Development:

More information

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006) October 2006 RESTRICTED LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006) DRAFT FOR DISCUSSION World Health Organization 2006 All rights reserved. This draft is intended for

More information

Comparison of the Reversed-Phase Selectivity of Solid Core HPLC Columns

Comparison of the Reversed-Phase Selectivity of Solid Core HPLC Columns omparison of the Reversed-Phase Selectivity of Solid ore HPL olumns M. Dolci, L. Pereira, Thermo Fisher Scientific, Runcorn, heshire, UK Technical Note 20788 Key Words Accucore, solid core, column characterization,

More information

Ultra Performance LC with Photo Diode Array Detection for the Development of Methods: Impurity Profiling and Long Term Stability Studies

Ultra Performance LC with Photo Diode Array Detection for the Development of Methods: Impurity Profiling and Long Term Stability Studies Ultra Performance LC with Photo Diode Array Detection for the Development of Methods: Impurity Profiling and Long Term Stability Studies Pittsburgh Conference Orlando, FL 14MAR06 Observations The pressure

More information

Protein Separation Technology

Protein Separation Technology [ ] Protein Separation Technology Protein Separation Technology The analysis and characterization of protein samples requires the detection of small chemical differences between large molecules. Most often

More information

HPLC Column Selection

HPLC Column Selection HPLC Column Selection A Comparison of Reversed- Columns d on the widely accepted work and data of Drs. Lloyd Snyder and John Dolan. 1,2 Grace has developed this column selection tool for choosing reversed

More information

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs Application Note: 439 UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs Guifeng Jiang, Thermo Fisher Scientific, San Jose, CA, USA Key Words Accela UHPLC System MSQ Plus MS Detector Drugs

More information

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research J. Jones, J. Denbigh, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20581 Key Words SPE, SOLA,

More information

Efficiently analyze your most challenging compounds. Deliver high-quality results faster. Agilent ZORBAX Column Selection Guide for HPLC

Efficiently analyze your most challenging compounds. Deliver high-quality results faster. Agilent ZORBAX Column Selection Guide for HPLC Efficiently analyze your most challenging compounds. Deliver high-quality results faster. Agilent ZORBAX Column Selection Guide for HPLC Agilent ZORBAX Column Selection Guide for HPLC Here it is your single

More information

Solid Phase Extraction Products PAGE: 1. Introduction of Solid Phase Extraction (SPE) Why Choose Nano-Micro Tech SPE

Solid Phase Extraction Products PAGE: 1. Introduction of Solid Phase Extraction (SPE) Why Choose Nano-Micro Tech SPE Solid Phase Extraction Products PAGE: 1 Introduction of Solid Phase Extraction (SPE) SPE has been used increasingly in chemical analysis and purification broadly, and become the most popular technology

More information

The Theory of HPLC. Gradient HPLC

The Theory of HPLC. Gradient HPLC The Theory of HPLC Gradient HPLC i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference manual. Aims

More information

TCI Chiral HPLC Column

TCI Chiral HPLC Column TCI Chiral HPLC Column ~ Spiral Polymer New Chiral Stationary Phase ~ Tokyo Chemical Industry Co.,Ltd. Chromatography Department 29 Tokyo Chemical Industry Co., Ltd. Features of TCI Chiral A unique new

More information

Thermo Scientific Chromatography Columns and Consumables 2014-2015. Your world of. chromatography

Thermo Scientific Chromatography Columns and Consumables 2014-2015. Your world of. chromatography Thermo Scientific Chromatography Columns and Consumables 214-215 Your world of chromatography predictability LC Columns and Accessories Thermo Scientific Chromatography Columns and Consumables 214-215

More information

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan Fast, Reproducible LC-MS/MS Analysis of and Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 685 Key Words Accucore C18, dextromethorphan, dextrorphan, SOLA CX Abstract

More information

Analytical HPLC Column Introduction

Analytical HPLC Column Introduction hplc columns introduction Analytical HPLC Column Introduction Grace Key Column Families Single-Source Solution for Discovery to Recovery Applications HPLC is commonly used in a wide range of applications,

More information

Analysis of Fat-Soluble Vitamin Capsules using UltraPerformance Convergence Chromatography (UPC 2 )

Analysis of Fat-Soluble Vitamin Capsules using UltraPerformance Convergence Chromatography (UPC 2 ) Analysis of Fat-Soluble Vitamin Capsules using UltraPerformance Convergence Chromatography (UPC 2 ) Andrew Aubin Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S Fast analysis of

More information

Gas Chromatography Liner Selection Guide

Gas Chromatography Liner Selection Guide Gas Chromatography Liner Selection Guide Peter Morgan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20551 Key Words Liner, focus Abstract The liner serves an important function in allowing

More information

Application Note. Determination of Amino acids by UHPLC with automated OPA- Derivatization by the Autosampler. Summary. Fig. 1.

Application Note. Determination of Amino acids by UHPLC with automated OPA- Derivatization by the Autosampler. Summary. Fig. 1. Application Note Determination of Amino acids by UHPLC with automated PA- Derivatization by the Autosampler Category Bio Analysis Matrix - Method UHPLC Keywords Proteinogenic Amino acids, Canonical Amino

More information

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water Application Notes # LCMS-35 esquire series Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water An LC-APCI-MS/MS method using an ion trap system

More information

HPLC Column Comparison Screening Study for Reversed Phase Columns

HPLC Column Comparison Screening Study for Reversed Phase Columns HPLC Column Comparison Screening Study for Reversed Phase Columns Carmen T. Santasania, Eric M. Snyder, Matilal Sarker, and Tracy L. Ascah Supelco, 595 North Harrison Road, Bellefonte, PA 16823, USA T403058

More information

HPLC Flash TLC GC SPE www.discoverysciences.com

HPLC Flash TLC GC SPE www.discoverysciences.com Chromatography Essentials HPLC Flash TLC GC SPE www.discoverysciences.com Table of Contents HPLC Columns 5 HPLC Accessories 6 30 Flash Products 3 34 TLC Products 35 37 GC Columns 38 45 GC Accessories 46

More information

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS Stephen Lock 1 and Matthew Noestheden 2 1 AB SCIEX Warrington, Cheshire (UK), 2 AB SCIEX Concord, Ontario (Canada) Overview A rapid,

More information

A feasibility study of the determination of B-group vitamins in food by HPLC with Mass Spectrometric detection. LGC/R/2011/181 LGC Limited 2011

A feasibility study of the determination of B-group vitamins in food by HPLC with Mass Spectrometric detection. LGC/R/2011/181 LGC Limited 2011 A feasibility study of the determination of B-group vitamins in food by HPLC with Mass Spectrometric detection LGC/R/2011/181 LGC Limited 2011 GC11/0005A A feasibility study of the determination of B-group

More information

The Essential CHROMacademy Guide. Mobile Phase Optimization Strategies for Reversed Phase HPLC

The Essential CHROMacademy Guide. Mobile Phase Optimization Strategies for Reversed Phase HPLC The Essential CHROMacademy Guide Mobile Phase Optimization Strategies for Reversed Phase HPLC Webcast Notes Type your questions in the Submit Question box, located below the slide window You can enlarge

More information

Standard Analytical Methods of Bioactive Metabolitesfrom Lonicera japonica Flower Buds by HPLC-DAD and HPLC-MS/MS

Standard Analytical Methods of Bioactive Metabolitesfrom Lonicera japonica Flower Buds by HPLC-DAD and HPLC-MS/MS Standard Analytical Methods of Bioactive Metabolitesfrom Lonicera japonica Flower Buds by HPLCDAD and HPLCMS/MS Jongheon Shin College of Pharmacy Seoul National University Summary The standard analytical

More information

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates Paula Hong and Kenneth J. Fountain Waters Corporation, 34 Maple St., Milford, MA, USA APPLICATION

More information

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control Dr. Frank Steiner, 1 Andreas Brunner, 1 Fraser McLeod, 1 Dr. Sergey Galushko 2 1 Dionex Corporation, Germering,

More information

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance Thermo Scientific SOLA SPE cartridges and plates Technical Guide Join the revolution unparalleled performance Join the revolution next-generation SPE Thermo Scientific SOLA products revolutionize Solid

More information

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008) Method OIV-MA-AS313-22 Type II method Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008) 1. Introduction

More information

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide chromatography Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide The following guide provides considerations, tips and general guidelines for developing SPE methods using the Thermo

More information

This handbook presents the basic principles of reversed-phase HPLC for the

This handbook presents the basic principles of reversed-phase HPLC for the Third Edition, 2002 This handbook presents the basic principles of reversed-phase HPLC for the analysis and purification of polypeptides. For further details regarding reversed-phase HPLC separations of

More information

[ Care and Use Manual ]

[ Care and Use Manual ] ACQUITY UPLC CSH Columns Contents I. Getting started a. Column Connectors b. Column Installation c. Column Equilibration d. ecord Installation e. Initial Column Efficiency Determination f. VanGuard Pre-Columns

More information

Eleanor Riches Waters Corporation, Manchester, UK INTRODUCTION

Eleanor Riches Waters Corporation, Manchester, UK INTRODUCTION X E V O T Q MS W IT H AT MOS P H E RIC P R E S SU R E P HOT O IO NIZ AT IO N (A P P I) SOU RC E: T H E IONIZATION OF COMPOUNDS WITH DIVERSE STRUCTURES USING VITAMINS AS A MODEL Eleanor Riches Waters Corporation,

More information

Agilent ZORBAX HPLC Column Selection Guide for Biotechnology. Resolution that Lasts

Agilent ZORBAX HPLC Column Selection Guide for Biotechnology. Resolution that Lasts Agilent ZORBAX HPLC Column Selection Guide for Biotechnology Resolution that Lasts Bioanalytical Chromatography from Agilent Technologies The variety and number of bioanalytical HPLC applications continue

More information

Purification of reaction mixtures using flash chromatography.

Purification of reaction mixtures using flash chromatography. Purification of reaction mixtures using flash chromatography. This technical note details the use of ISOLUTE Flash chromatography columns for the purification of reaction mixtures. What is flash chromatography?

More information

Size Exclusion Chromatography

Size Exclusion Chromatography Size Exclusion Chromatography TOYOPEARL Resins for SEC TOYOPEARL TOYOPEARL TOYOPEARL HW-55 TOYOPEARL HW-65 TOYOPEARL TOSOH BIOSCIENCE TOSOH BIOSCIENCE LLC 56 Keystone Drive Montgomeryville, PA 896-967

More information

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax. Standard Method for Analysis of Benzene and Toluene Content in Hydrocarbon Waxes by Headspace Gas Chromatography EWF METHOD 002/03 (Version 1 Reviewed 2015) 1 Scope 1.1 This test method covers the qualitative

More information

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns Product Manual for SolEx TM HRP Cartridges and SolEx TM HRP RSLC Columns Page 1 of 15 Product Manual for SolEx TM HRP Cartridges SolEx HRP (P/N 074400)

More information

SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY CHAPTER 5 SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY CHAPTER 5 Simultaneous determination of Telmisartan

More information

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension International Journal of PharmTech Research CODEN (USA): IJPRIF ISSN : 0974-4304 Vol.2, No.2, pp 1634-1638, April-June 2010 Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination

More information

Innovative vs Traditional

Innovative vs Traditional And in the red corner, introducing the challenger NASDAQ April 4 2011 243.47 $ 1.38 $ 0.58 % 0.07 $ 0.02 $ 39.4 % Technology DVD Digital Streamline Instant Play Internet Access Unlimited Selection No Late

More information

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation Craig Aurand 1, David Bell 1, Anders Fridstrom 2, and Klaus Buckendahl 2 1 Supelco, Div.

More information

Application Note. Separation of three monoclonal antibody variants using MCSGP. Summary

Application Note. Separation of three monoclonal antibody variants using MCSGP. Summary Application Note Separation of three monoclonal antibody variants using MCSGP Category Matrix Method Keywords Analytes ID Continuous chromatography, Biochromatography; FPLC Protein A-purified monoclonal

More information

ABRF 2004 Poster# P55-S Displacement Chromatography Effects Can Cause Highly Selective Sampling of Peptides During Solid Phase Extraction Cleanup

ABRF 2004 Poster# P55-S Displacement Chromatography Effects Can Cause Highly Selective Sampling of Peptides During Solid Phase Extraction Cleanup ABRF 2004 Poster# P55-S Displacement Chromatography Effects Can Cause Highly Selective Sampling of Peptides During Solid Phase Extraction Cleanup by Andrew J. Alpert PolyLC Inc./ 9151 Rumsey Road, ste.

More information

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols. An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols. Jaap de Zeeuw, Ron Stricek and Gary Stidsen Restek Corp Bellefonte, USA To analyze basic compounds at

More information

High-Throughput 3-D Chromatography Through Ion Exchange SPE

High-Throughput 3-D Chromatography Through Ion Exchange SPE High-Throughput 3-D Chromatography Through Ion Exchange SPE Application Note 205 Luke Roenneburg and Alan Hamstra (Gilson, Inc.) Introduction 2-dimensional (2-D) separation is the separation of a sample

More information

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants Metabolomic Profiling of Accurate Mass LC- Data to Identify Unexpected Environmental Pollutants André Schreiber 1, David Cox 1, Nadia Pace 1, Christopher Borton 2 1 AB SCIEX, Concord, ntario, Canada; 2

More information

Application Note. Purifying common light-chain bispecific antibodies using MCSGP. Summary

Application Note. Purifying common light-chain bispecific antibodies using MCSGP. Summary Application Note Purifying common light-chain bispecific antibodies using MCSGP Category Matrix Method Keywords Analytes ID Continuous chromatography, biochromatography Antibodies MCSGP Bispecific antibody,

More information

Carbohydrate Analysis: Column Chemistries and Detection

Carbohydrate Analysis: Column Chemistries and Detection Carbohydrate Analysis: Column Chemistries and Detection Joe Romano Waters Corporation Carbohydrates in Feeds Methodology Forum AOAC 2007 Annual Meeting Anaheim, CA September 18, 2007 2007 Waters Corporation

More information

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection 52 May/June 2012 Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection by Karen Rome and Allyson McIntyre, AstraZeneca, Macclesfield, SK10 2NA, UK Quantitative analysis

More information

Analysis of Vegetable Oils by High Performance Liquid Chromatography

Analysis of Vegetable Oils by High Performance Liquid Chromatography Analysis of Vegetable Oils by High Performance Liquid Chromatography Using Evaporative Light Scattering Detection and Normal Phase Eluents Andrew J. Aubin, Cecilia B. Mazza, Donald A. Trinite, and Patricia

More information

Application Note. Increasing the activity of monoclonal antibody isoforms by MCSGP. Summary

Application Note. Increasing the activity of monoclonal antibody isoforms by MCSGP. Summary Application Note Increasing the activity of monoclonal antibody isoforms by MCSGP Category Matrix Method Keywords Countercurrent chromatography, FPLC Antibodies MCSGP FPLC, Biobetters, MCSGP, countercurrent

More information

INSTRUCTIONS 56-1190-98. Edition AC

INSTRUCTIONS 56-1190-98. Edition AC Sephacryl S-100 High Resolution Sephacryl S-200 High Resolution Sephacryl S-300 High Resolution Sephacryl S-400 High Resolution Sephacryl S-500 High Resolution INSTRUCTIONS Sephacryl High Resolution chromatography

More information

HPLC Basics, Equipment, and Troubleshooting

HPLC Basics, Equipment, and Troubleshooting HPLC Basics, Equipment, and Troubleshooting HPLC Basics, Equipment, and Troubleshooting explains chromatography in practical terms from the ground up HPLC Basics, Equipment, and Troubleshooting HPLC Basics,

More information

Contents. List of Contributors XIII The structure of The HPLC-Expert" Preface XVII

Contents. List of Contributors XIII The structure of The HPLC-Expert Preface XVII V List of Contributors XIII The structure of The HPLC-Expert" Preface XVII XV 1 LC/MS Coupling 1 1.1 State of the Art in LC/MS 1 Oliver Schmitz 1.1.1 Introduction 1 1.1.2 Ionization Methods at Atmospheric

More information

Pipette Tips PACKARD BIOSCIENCE MultiPROBE II COMPATIBLE

Pipette Tips PACKARD BIOSCIENCE MultiPROBE II COMPATIBLE User Guide for Reversed-Phase Pipette Tips PACKARD BIOSCIENCE MultiPROBE II COMPATIBLE Notice The information in this document is subject to change without notice and should not be construed as a commitment

More information

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from uman Plasma Krishna Rao Dara, Dr. Tushar N. Mehta, Asia Pacific Center of Excellence, Thermo Fisher Scientific, Ahmedabad, India Application

More information

Diffusion and Fluid Flow

Diffusion and Fluid Flow Diffusion and Fluid Flow What determines the diffusion coefficient? What determines fluid flow? 1. Diffusion: Diffusion refers to the transport of substance against a concentration gradient. ΔS>0 Mass

More information

Scharlau Chromatography Supplies. Scharlab The Lab Sourcing Group

Scharlau Chromatography Supplies. Scharlab The Lab Sourcing Group Scharlau Chromatography Supplies Scharlab The Lab Sourcing Group Scharlau HPLC & LC/MS columns and supplies HPLC & LC/MS Scharlau columns. KromaPhase For over 30 years, Spanish scientists have been working

More information

Certificate of Analysis

Certificate of Analysis National Institute of Standards & Technology Certificate of Analysis Standard Reference Material 870 Column Performance Test Mixture for Liquid Chromatography This Standard Reference Material (SRM) is

More information

IAM Chromatography. HPLC Separation Tools for Membrane Protein Purification and Drug Membrane Permeability Prediction

IAM Chromatography. HPLC Separation Tools for Membrane Protein Purification and Drug Membrane Permeability Prediction IAM Chromatography Immobilized Artificial Membrane (IAM) technology is an innovative approach to chromatography in which the chromatographic surface emulates the lipid environment of the cell membrane.

More information

Hydrophilic-Interaction Chromatography (HILIC) for LC-MS/MS Analysis of Monoamine Neurotransmitters using XBridge BEH Amide XP Columns

Hydrophilic-Interaction Chromatography (HILIC) for LC-MS/MS Analysis of Monoamine Neurotransmitters using XBridge BEH Amide XP Columns Hydrophilic-Interaction Chromatography (HILIC) for LC-MS/MS Analysis of Monoamine Neurotransmitters using XBridge BEH Amide XP Columns Jonathan P. Danaceau, Kenneth J. Fountain, and Erin E. Chambers Waters

More information

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY 9.1 POLICY This test method may be used to confirm the presence of zolpidem (ZOL), with diazepam-d 5 (DZP-d 5 ) internal standard, in

More information

A Guide to HPLC and LC-MS Buffer Selection

A Guide to HPLC and LC-MS Buffer Selection A Guide to HPLC and LC-MS Buffer Selection HPLC Columns John Dolan Your decision has lasting effects. Choose wisely. HPLC Columns Ultra Inert Base-Deactivated HPLC Columns For Performance, Selectivity

More information

[ Care and Use Manual ]

[ Care and Use Manual ] Analytical columns and cartridges i. Introduction Waters offers a large selection of analytical columns and cartridges packed with silica-based packing materials. Follow this instruction sheet to obtain

More information

A Guide to the Analysis and Purification of Proteins and Peptides by Reversed-Phase HPLC

A Guide to the Analysis and Purification of Proteins and Peptides by Reversed-Phase HPLC A Guide to the Analysis and Purification of Proteins and Peptides by Reversed-Phase HPLC HPLC Columns David Carr Your decision has lasting effects. Choose wisely. HPLC Columns Ultra Inert Base-Deactivated

More information

Quality by Design Approach for the Separation of Naproxcinod and its Related Substances by Fused Core Particle Technology Column

Quality by Design Approach for the Separation of Naproxcinod and its Related Substances by Fused Core Particle Technology Column Journal of Chromatographic Science Advance Access published October 11, 2012 Journal of Chromatographic Science 2012;00:1 7 doi:10.1093/chromsci/bms162 Article Quality by Design Approach for the Separation

More information

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder Lecture Chromo-3: Gas Chromatography CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder Outline Introduction Instrument overview Carrier gas Sample

More information

Electrospray Ion Trap Mass Spectrometry. Introduction

Electrospray Ion Trap Mass Spectrometry. Introduction Electrospray Ion Source Electrospray Ion Trap Mass Spectrometry Introduction The key to using MS for solutions is the ability to transfer your analytes into the vacuum of the mass spectrometer as ionic

More information

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis Thermo Scientific SOLAµ SPE Plates Technical Guide Consistent excellence for bioanalysis SOLAµ - delivering reproducible low volume extractions. Everytime! Thermo Scientific SOLAµ plates are designed for

More information

Application Note. Determination of 17 AQC derivatized Amino acids in baby food samples. Summary. Introduction. Category Bio science, food Matrix

Application Note. Determination of 17 AQC derivatized Amino acids in baby food samples. Summary. Introduction. Category Bio science, food Matrix Application Note Determination of 17 AQC derivatized Amino acids in baby food samples Category Bio science, food Matrix Baby food Method UHPLC Keywords Proteinogenic amino acids, canonical amino acids,

More information

PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative

PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative PLOT Columns Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative PLOT Column Selection 93 Features & Benefits of Restek PLOT Columns Features

More information

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process Save Hours in Sample Preparation Reduce the time to prepare and inject samples

More information

A Complete Solution for Method Linearity in HPLC and UHPLC

A Complete Solution for Method Linearity in HPLC and UHPLC Now sold under the Thermo Scientific brand A Complete Solution for Method Linearity in HPLC and UHPLC Frank Steiner, Fraser McLeod, Tobias Fehrenbach, and Andreas Brunner Dionex Corporation, Germering,

More information

Articaine & Epinephrine Injection according to USP method

Articaine & Epinephrine Injection according to USP method Application Note Biotech & pharmaceutical The most reliable LC-EC applications for Pharmaceutical & Biotech analysis ever formulated Aminoglycosides Amikacin Framycetin Sulphate Gentamicin Sulphate Kanamycin

More information

ANALYTICAL METHODS INTERNATIONAL QUALITY SYSTEMS

ANALYTICAL METHODS INTERNATIONAL QUALITY SYSTEMS VALIDATION OF ANALYTICAL METHODS 1 GERT BEUVING INTERNATIONAL PHARMACEUTICAL OPERATIONS TASKS: - Internal auditing - Auditing of suppliers and contract manufacturers - Preparing for and guiding of external

More information

Aspects of industrial purification of peptides using large-scale chromatography. Lars Andersson and Jonas Persson

Aspects of industrial purification of peptides using large-scale chromatography. Lars Andersson and Jonas Persson Aspects of industrial purification of peptides using large-scale chromatography Introduction By Lars Andersson and Jonas Persson PolyPeptide Laboratories (Sweden) AB PO Box 30089 SE-200 61 LIMHAMN SWEDEN

More information

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods SPE Introduction How to Choose an SPE Product 1. Characterize the Sample Factors such as the analyte s polarity relative to the matrix, the presence of charged functional groups, solubility, molecular

More information

Journal of Chemical and Pharmaceutical Research

Journal of Chemical and Pharmaceutical Research Available on line www.jocpr.com Journal of Chemical and Pharmaceutical Research J. Chem. Pharm. Res., 2010, 2(1): 91-99 ISSN No: 0975-7384 A Stability-Indicating RP-LC method for the Determination of Related

More information

SSENTIALS RESTEK. A new species of column. Restek Certified. SPP speed. USLC resolution. Restek s EZGC Online Suite. Reference Materials

SSENTIALS RESTEK. A new species of column. Restek Certified. SPP speed. USLC resolution. Restek s EZGC Online Suite. Reference Materials Now in 2.7 and 5 µm particles! Speed Up and mplify GC Method Development With Restek s EZGC nline Suite SSENTIALS RESTEK Must-Have Solutions for Your Lab 2014.4 SPP speed. USLC resolution. A new species

More information

General Chromatography

General Chromatography General Chromatography SPE....................... 296 316 SPE Introduction................... 296 299 Alltech SPE Sorbent Introduction.......... 300 301 Alltech Extract-Clean and Ultra-Clean Columns. 302

More information

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies Application Note Small Molecule Pharmaceuticals Authors Jignesh Shah, Tiantian Li, and Anil Sharma Agilent Technologies,

More information

Monoclonal Antibody Fragment Separation and Characterization Using Size Exclusion Chromatography Coupled with Mass Spectrometry

Monoclonal Antibody Fragment Separation and Characterization Using Size Exclusion Chromatography Coupled with Mass Spectrometry Monoclonal ntibody Fragment Separation and haracterization Using Size Exclusion hromatography oupled with Mass Spectrometry uthors Haiying hen Katherine McLaughlin Sepax Technologies, Inc. 5 Innovation

More information

Tamsulosin Hydrochloride Capsules

Tamsulosin Hydrochloride Capsules . nal Revision Bulletin Official October 1, 2011 Tamsulosin 1 standard solution, and shake well. Centrifuge at 1500 rpm for 10 min, and use the supernatant, passing it if Tamsulosin Hydrochloride Capsules

More information

Henry Shion, Robert Birdsall, Steve Cubbedge, and Weibin Chen Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Henry Shion, Robert Birdsall, Steve Cubbedge, and Weibin Chen Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS Development of Integrated Informatics Workflows for the Automated Assessment of Comparability for Antibody Drug Conjugates (ADCs) Using LC-UV and LC-UV/MS Henry Shion, Robert Birdsall, Steve Cubbedge,

More information

SPE Reference Manual & Users Guide. Reference Manual & Users Guide

SPE Reference Manual & Users Guide. Reference Manual & Users Guide SM SPE Reference Manual & Users Guide SPE Reference Manual & Users Guide Reference Manual & Users Guide SPE Table of Contents Page No. 1. Objective and Purpose of This Guide 1 2. Solid Phase Extraction

More information

Reversed Phase Chromatography

Reversed Phase Chromatography Reversed Phase Chromatography Principles and Methods 18-1134-16 Edition AA Reversed Phase Chromatography Contents 1. Introduction... 5 Theory of reversed phase chromatography... 6 The matrix... 9 The ligands...

More information

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate

More information