Unique Bonding Chemistry
|
|
|
- Fay Morris
- 9 years ago
- Views:
Transcription
1 columns Acclaim HPLC Columns Reversed-phase silica columns for pharmaceutical, nutraceutical, environmental, food, and life science applications in HPLC. High hydrophobicity, low polarity phases LC/MS compatible Very high efficiencies Symmetrical peak shapes Reproducible columnto-column manufacturing Ultrapure silica Stable bonding chemistry Unique Bonding Chemistry The Acclaim line of HPLC columns is a new line of C8 and C8 silica-based, reversed-phase columns manufactured by Dionex using exhaustive bonding and end-capping techniques. Among the many C8 columns on the market, retention behavior of analytes differs significantly due to variation in both the raw silica and the ligand bonding chemistry and density. The Acclaim columns address many of the performance issues encountered with octadecylsilylated silica gel (ODS) columns. The Acclaim line is comprised of four highly characterized C8 and C8 phases, manufactered using highpurity silica with a Å pore diameter, with very high surface coverage and very low metal content. All the phases are LC-MS compatible with very low background and good capacity ideal for use with high organic mobile phases. The C8 phases exhibit low polarity, high hydrophobicity, and good steric selectivity, which result in high-capacity columns with unique selectivity. All Dionex columns undergo extensive testing to ensure column-tocolumn reproducibility, and are shipped with certificates of analysis detailing these tests.
2 -Uracil - Propranolol - Toluene Figure. Dilution of bases. - Doxepin Figure. Extract of goldenseal root..86 na Figure. Baseline separation of catecholamines and serotonin. 5 - Amitriptyline Column: Acclaim 5 µm C8 Dimensions:.6 5 mm Mobile phase: 8/ Methanol/ mm phosphate ph 6 Temp. : C Flow rate: ml/min Detection: UV, nm Amitriptyline Mass Trace : ng Trace : ng Trace : 9 ng Peaks:. Protriptyline. Desipramine. Nortriptyline. Imipramine 5. Amitriptyline Column: Acclaim 5 µm C8 Dimensions:.6 5 mm Mobile Phase A:.% H PO in D.I. H O Mobile Phase B: Acetonitrile Eluent: (A) 7%, (B) 7% Flow rate.8 ml/min Injection Vol: µl Detection: UV, 5 nm Peaks:. Hydrastine. Berberine Column: Acclaim 5 µm C8 Dimensions:.6 5 mm Mobile phase: 57 mm citric acid, mm sodium acetate,. mm EDTA, mm sodium octanesulfonate, % methanol Flow Rate: ml/min Detection: DC Amperometry, Glassy Carbon at 7 mv vs Ag/AgCl Peaks:. Norepinephrine pmol. Epinephrine. Dihydroxybenzylamine. Dopamine 5. Serotonin Symmetrical Peak Shapes Peak tailing in RP-HPLC is a problem that affects peak resolution and integration. For basic analytes, it results in large part from the ion-exchange interaction of positively charged, basic analytes with negatively charged, exposed silanol groups. Above ph ~, the surface silanols begin to deprotonate and interact with basic analytes. This effect can be reduced by optimizing the surface coverage of the bonded phase, exhaustive end-capping of the residual silanol groups and minimizing metal contaminants that increase the acidity of the free silanol groups. The tailing on amitriptyline is a very good indicator of the number of exposed silanol groups. As the mass loading of the base onto a column decreases, the performance of a column can be seen more clearly. Figure shows the separation of a group of bases, including amitriptyline, at three analyte concentrations. The toluene is present as a marker. The responses have been normalized to show all three chromatograms with peaks at the same height. Acclaim phases give excellent results, even as the base analyte concentrations approach very low levels. Figure shows the separation of components in an extract of Goldenseal root. This application provides a good indication of the purity of the silica. The cleaner the silica, the more symmetrical the berberine peak. Figure shows the baseline separation of catecholamines using a 5-µm C8 Acclaim stationary phase and an isocratic mobile phase. The high efficiency 5-µm Acclaim columns provide good resolution that can be further enhanced by using the -µm particle size. This separation is useful for extracts of brain tissue. The 5- hydroxy precursor of serotonin can also be separated on the same column. The separation can be optimized for serotonin by increasing the concentration of methanol or using one of the shorter formats of the Acclaim columns.
3 LC-MS Compatible More scientists are turning to mass spectrometry detection as the demand for product characterization increases. Historically, many reversed-phase columns have not been compatible with mass spectrometers due to silica bleeding into the mass spectrometer. To address this issue, some column manufacturers have developed a line of specialty columns specifically for LC-MS applications. The Dionex Acclaim columns use ultrapure silica with a stable bonding procedure to deliver a single line of columns that are LC-MS compatible. Figure shows the separation of a mixture of pesticides in less than min. using a. mm i.d. mm format column. The hydrophobicity of this phase allows the use of higher solvent levels in the mobile phase for better sensitivity by electrospray mass spectrometry. Food Applications The Dionex Acclaim is a rugged and reliable product line, ideally suited to applications, such as food products, that are subjected to regulatory control. The high efficiencies of these columns combined with their high capacity produce sharp, narrow peaks that are readily quantified, as illustrated by the separation of fat-soluble vitamins A, E, D, and D from the beta- and delta-tocopherol impurities in Figure 5. The high efficiencies of these columns allow not only for better resolution between difficult peak pairs, but also for good sensitivity of the trace components. 5 5 Figure. LC-MS of pesticides. - Figure 5. Fat soluble vitamins. Column: Acclaim µm C8 Dimensions:. mm Mobile Phase: 7/% methanol/.% formic acid Flow rate.5 ml/min Detection: AQA MS, +ESI, V, C, SIM as indicated m/z mass injected Peaks:. Monuron 99 ng. Altrazine 6. ng. Propazine ng. Diuron.5 ng 5. Linuron 9 ng Column: Acclaim µm C8 Peaks:. All-trans retinol (Vitamin A). mg/ml Dimensions:.6 5 mm. δ-tocopherol (impurity) Eluent: 95/5 v/v acetonitrile/methanol. Ergocalciferol (Vitamin D ). Flow Rate:. ml/min. Cholecalciferol (Vitamin D ).6 Inj. Vol.: 5 µl 5. β-tocopherol (impurity) Temp.: C 6. α-tocopherol (Vitamin E). Detection: UV, 8 nm
4 Pharmaceuticals Acclaim columns are also well suited to pharmaceutical applications. With the tight specifications applied to the entire column manufacturing process, from the physical characteristics of the raw silica to the bonding chemistry and column testing, these columns provide good peak shapes and reproducible chromatography from one column to the next. Figure 7 and 8 show separations of benzodiazepines and antihistamines. Note the enhanced peak resolution of the antihistamine compounds in Figure 8, which allows for identification of minor contaminant peaks Column: Acclaim 5 µm C8 Dimensions:.6 5 mm Mobile Phase: 6% acetonitrile Flow rate:. ml/min Detection: UV, 5 nm Peaks:. Oxazepam. Clonazepam. Temazepam. Diazepam 75 Natural Products With the increased interest in natural products in recent years, the identification of nutraceutical marker compounds has received much attention in HPLC method development. This importance is reflected by the publication of a series of HPLC methods by the Institute for Nutraceutical Advancement (INA). The Dionex Acclaim columns are packed with a highly characterized bonded phase that interacts with polar compounds, such as those shown in Figure 9, in a predictable and reproducible manner. These columns provide excellent peak shape and good resolution for a wide variety of natural products. Figure shows the separation of isoflavones in red clover. Isoflavones are important as potential immuneenhancers and anticancer agents. Figure 7. Benzodiazepines. 6 8 Figure 8. Antihistamines. 5 Column: Acclaim 5 µm C8 Dimensions:.6 5 mm Mobile Phase A: 5 mm sodium acetate Mobile Phase B: Methanol Isocratic: (A) %, (B) 8% Temperature: 5 C Detection: UV, 9 nm Peaks:. Thenyldiamine HCI. Phenothiazine. Promethazine HCI. Pyrrobutamine phosphate Column: Acclaim 5 µm C8 Dimensions:.6 5 mm Mobile Phase A: 5 mm sodium acetate Mobile Phase B: Acetonitrile Mobile Phase C: Methanol Composition: (A) 6%, (B) 8%, (C) 6% Flow rate:. ml/min Detection: UV, 7 nm Peaks:. 7-Methylxanthine. Theobromine. Theophylline. Caffeine Figure 9. Caffeine analogs.
5 Manufacturing Reproducibility Scientists working on products for human consumption, whether they are pharmaceuticals, food products, or nutraceuticals, are under a great deal of pressure to produce fast and accurate results. Whether these scientists are working under the International Conference on Harmonization (ICH) guidelines or fall under the jurisdiction of the FDA, it is important that their analytical methods are rugged and reliable. To meet the needs of these scientists, each Acclaim column is manufactured according to stringent specifications to ensure column-tocolumn reproducibility. Each column is shipped with a lot validation sheet showing the test results and specifications for the lot of bonded silica packed into the column and an individual test chromatogram detailing the extensive testing to which it has been subjected. The lot validation includes a chromatography-based metals test and tests for polar selectivity, hydrophobic steric selectivity, and base asymmetry. Production columns are tested for capacity and efficiency, and closely monitored for metal contamination. Acclaim guard cartridges are packed with the same validated, 5-µm, bonded silicas that are used to pack the analytical columns. By using analytical-quality bonded phase in the guard cartridges, selectivity changes due to mismatched guards and columns are minimized Figure. Isoflavones in red clover. SPECIFICATIONS Column Acclaim 5 µm, C8 Dimensions:.6 x 5 mm Mobile Phase A:.% H PO in D.I. H O Mobile Phase B: Acetonitrile Gradient: % B to 76% B over 5 min Flow rate:. ml/min Injection Vol: µl Detection: UV, 6 nm Peaks:. Genistin 5. Ononin. Sissotrin. Formononotin 5. Biochanin A C8 C8 USP Listing L L7 Starting Material Ultrapure silica Ultrapure silica Particle Size µm, 5 µm µm, 5 µm Particle Shape Spherical Spherical Particle Size Distribution (/9).. Total Carbon Content (%) 8.. Carbon Surface Coverage (µmol/m )..7 End-Capped Yes Yes Metal Impurity (ppm) Na, Fe, Al < < Pore Volume (ml/g).9.9 Average Pore Diameter (Å) Surface Area (m /g) ph range 8 8 Temperature <6 C <6 C 769
6 Ordering Information To order in the U.S., call (8) 6-69, or contact the Dionex regional office nearest you. Outside the U.S., order through your local Dionex office or distributor. Refer to the following part numbers. PART NUMBERS Analytical Columns Part Number Acclaim, C8, µm Analytical (. 5 mm) 59 Acclaim, C8, µm Analytical (. mm) 59 Acclaim, C8, µm Analytical (. 5 mm) 59 Acclaim, C8, µm Analytical (.6 5 mm) 595 Acclaim, C8, µm Analytical (.6 mm) 596 Acclaim, C8, µm Analytical (.6 5 mm) 597 Acclaim, C8, µm Analytical (. 5 mm) 598 Acclaim, C8, µm Analytical (. mm) 599 Acclaim, C8, µm Analytical (. 5 mm) 59 Acclaim, C8, µm Analytical (.6 5 mm) 59 Acclaim, C8, µm Analytical (.6 mm) 59 Acclaim, C8, µm Analytical (.6 5 mm) 59 Acclaim, C8, 5 µm Analytical (. 5 mm) 59 Acclaim, C8, 5 µm Analytical (. mm) 595 Acclaim, C8, 5 µm Analytical (. 5 mm) 596 Acclaim, C8, 5 µm Analytical (. 5 mm) 597 Acclaim, C8, 5 µm Analytical (.6 5 mm) 598 Acclaim, C8, 5 µm Analytical (.6 mm) 599 Acclaim, C8, 5 µm Analytical (.6 5 mm) 59 Acclaim, C8, 5 µm Analytical (.6 5 mm) 59 Acclaim, C8, 5 µm Analytical (. 5 mm) 59 Acclaim, C8, 5 µm Analytical (. mm) 59 Acclaim, C8, 5 µm Analytical (. 5 mm) 59 Acclaim, C8, 5 µm Analytical (. 5 mm) 595 Acclaim, C8, 5 µm Analytical (.6 5 mm) 596 Acclaim, C8, 5 µm Analytical (.6 mm) 597 Acclaim, C8, 5 µm Analytical (.6 5 mm) 598 Acclaim, C8, 5 µm Analytical (.6 5 mm) 599 Guard Columns Part Number 5-µm guard cartridges are used with both -µm and 5-µm analytical columns. Acclaim, C8, 5 µm Guard Cartridges ( mm), ea. 599 Acclaim, C8, 5 µm Guard Cartridges (. mm), ea. 598 Acclaim, C8, 5 µm Guard Cartridges ( mm), ea. 597 Acclaim, C8, 5 µm Guard Cartridges (. mm), ea. 596 Acclaim Guard Kit (holder and coupler) 5956 Acclaim SST Guard Cartridge Holder 5956 Guard to Analytical Column Coupler 5957 Acclaim is a registered trademark of Dionex Corporation. Dionex Corporation Dionex Corporation Dionex U.S. Regional Offices Dionex International Subsidiaries 8 Titan Way Salt Lake City Technical Center Sunnyvale, CA (8) Austria () Belgium () 5 9 Canada (95) China (85) 8 8 Denmark P.O. Box 6 55 West South, Suite A Westmont, IL (6) France 9 Germany Italy (6) Japan (6) The Netherlands (6) Sunnyvale, CA Salt Lake City, UT Houston, TX (8) Switzerland (6) United Kingdom (76) Atlanta, GA (77) -8 * Designed, developed, and manufactured under an NSAI registered ISO 9 Quality System. (8) 77-7 (8) Marlton, NJ (856) LPN - PDF 5/ Dionex Corporation
Thermo Scientific Syncronis HPLC Columns. Technical Manual
Thermo Scientific Syncronis HPLC Columns Technical Manual Thermo Scientific Syncronis HPLC Columns When developing a new method, one of the most important goals for the chromatographer is to achieve a
Comparison of the Reversed-Phase Selectivity of Solid Core HPLC Columns
omparison of the Reversed-Phase Selectivity of Solid ore HPL olumns M. Dolci, L. Pereira, Thermo Fisher Scientific, Runcorn, heshire, UK Technical Note 20788 Key Words Accucore, solid core, column characterization,
LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research
LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research J. Jones, J. Denbigh, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20581 Key Words SPE, SOLA,
Guide to Reverse Phase SpinColumns Chromatography for Sample Prep
Guide to Reverse Phase SpinColumns Chromatography for Sample Prep www.harvardapparatus.com Contents Introduction...2-3 Modes of Separation...4-6 Spin Column Efficiency...7-8 Fast Protein Analysis...9 Specifications...10
Determination of Calcium and Magnesium in Brine
Application Note Determination of Calcium and Magnesium in Brine INTRODUCTION To prevent membrane poisoning, new membrane technology in chlor-alkali cells requires feed brine that is relatively free of
The Determination of Sugars in Molasses by High-Performance Anion Exchange with Pulsed Amperometric Detection
Application Note 9 The Determination of Sugars in Molasses by High-Performance Anion Exchange with Pulsed Amperometric Detection INTRODUCTION The accurate measurement of the amount of sugar in final molasses
UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs
Application Note: 439 UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs Guifeng Jiang, Thermo Fisher Scientific, San Jose, CA, USA Key Words Accela UHPLC System MSQ Plus MS Detector Drugs
Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan
Fast, Reproducible LC-MS/MS Analysis of and Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 685 Key Words Accucore C18, dextromethorphan, dextrorphan, SOLA CX Abstract
A Complete Solution for Method Linearity in HPLC and UHPLC
Now sold under the Thermo Scientific brand A Complete Solution for Method Linearity in HPLC and UHPLC Frank Steiner, Fraser McLeod, Tobias Fehrenbach, and Andreas Brunner Dionex Corporation, Germering,
LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)
October 2006 RESTRICTED LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006) DRAFT FOR DISCUSSION World Health Organization 2006 All rights reserved. This draft is intended for
Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control
Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control Dr. Frank Steiner, 1 Andreas Brunner, 1 Fraser McLeod, 1 Dr. Sergey Galushko 2 1 Dionex Corporation, Germering,
The Essential CHROMacademy Guide. Mobile Phase Optimization Strategies for Reversed Phase HPLC
The Essential CHROMacademy Guide Mobile Phase Optimization Strategies for Reversed Phase HPLC Webcast Notes Type your questions in the Submit Question box, located below the slide window You can enlarge
Gas Chromatography Liner Selection Guide
Gas Chromatography Liner Selection Guide Peter Morgan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20551 Key Words Liner, focus Abstract The liner serves an important function in allowing
Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis
Thermo Scientific SOLAµ SPE Plates Technical Guide Consistent excellence for bioanalysis SOLAµ - delivering reproducible low volume extractions. Everytime! Thermo Scientific SOLAµ plates are designed for
The Theory of HPLC. Gradient HPLC
The Theory of HPLC Gradient HPLC i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference manual. Aims
# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water
Application Notes # LCMS-35 esquire series Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water An LC-APCI-MS/MS method using an ion trap system
Articaine & Epinephrine Injection according to USP method
Application Note Biotech & pharmaceutical The most reliable LC-EC applications for Pharmaceutical & Biotech analysis ever formulated Aminoglycosides Amikacin Framycetin Sulphate Gentamicin Sulphate Kanamycin
for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns
for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns Product Manual for SolEx TM HRP Cartridges and SolEx TM HRP RSLC Columns Page 1 of 15 Product Manual for SolEx TM HRP Cartridges SolEx HRP (P/N 074400)
Analysis of Fat-Soluble Vitamin Capsules using UltraPerformance Convergence Chromatography (UPC 2 )
Analysis of Fat-Soluble Vitamin Capsules using UltraPerformance Convergence Chromatography (UPC 2 ) Andrew Aubin Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S Fast analysis of
Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation
Application Note Determination of Nitrite and Nitrate in Fruit Juices by UV Detection Category Food Matrix Fruit Juice Method HPLC Keywords Ion pair chromatography, fruit juice, inorganic anions AZURA
Bulk Materials for Preparative and Process Chromatography
Bulk Materials for Preparative and Process Chromatography Silica Based HPLC Bulk Media Characteristics Available in both reversed and normal phases High chemical stability for low leaching High loading
Protein Separation Technology
[ ] Protein Separation Technology Protein Separation Technology The analysis and characterization of protein samples requires the detection of small chemical differences between large molecules. Most often
A Guide to HPLC and LC-MS Buffer Selection
A Guide to HPLC and LC-MS Buffer Selection HPLC Columns John Dolan Your decision has lasting effects. Choose wisely. HPLC Columns Ultra Inert Base-Deactivated HPLC Columns For Performance, Selectivity
Advantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites
Advantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites Carmen T. Santasania and David S. Bell SUPELCO, 595 North Harrison Road, Bellefonte, PA 16823 T404045 GUS Abstract
Application Note. Determination of Amino acids by UHPLC with automated OPA- Derivatization by the Autosampler. Summary. Fig. 1.
Application Note Determination of Amino acids by UHPLC with automated PA- Derivatization by the Autosampler Category Bio Analysis Matrix - Method UHPLC Keywords Proteinogenic Amino acids, Canonical Amino
Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates
Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates Paula Hong and Kenneth J. Fountain Waters Corporation, 34 Maple St., Milford, MA, USA APPLICATION
SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0) 1234 758322. [email protected].
SPE and HPLC Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0) 1234 758322 [email protected] Solid-Phase Extraction- SPE Simple, fast and efficient sample preparation
Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis
Application Note AN844 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Page 1 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis Introduction Catecholamines
Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection
Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection Derek Hillbeck, Thermo Fisher Scientific, Runcorn, UK Application Note 2999 Key
Application Note # LCMS-92 Interlaboratory Tests Demonstrate the Robustness and Transferability of the Toxtyper Workflow
Application Note # LCMS-92 Interlaboratory Tests Demonstrate the Robustness and Transferability of the Toxtyper Workflow Abstract There is high demand in clinical research and forensic toxicology for comprehensive,
Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method
Simultaneous Quantitation of 4 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method Xiang He and Marta Kozak, Thermo Fisher Scientific, San Jose, CA Application Note 76 Key Words TSQ Quantum Access
Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension
International Journal of PharmTech Research CODEN (USA): IJPRIF ISSN : 0974-4304 Vol.2, No.2, pp 1634-1638, April-June 2010 Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination
SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma
SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from uman Plasma Krishna Rao Dara, Dr. Tushar N. Mehta, Asia Pacific Center of Excellence, Thermo Fisher Scientific, Ahmedabad, India Application
Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance
Thermo Scientific SOLA SPE cartridges and plates Technical Guide Join the revolution unparalleled performance Join the revolution next-generation SPE Thermo Scientific SOLA products revolutionize Solid
Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation
Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation Craig Aurand 1, David Bell 1, Anders Fridstrom 2, and Klaus Buckendahl 2 1 Supelco, Div.
columns IonPac CS18 Cation-Exchange Column
columns IonPac CS Cation-Exchange Column The IonPac CS is a cation-exchange column of moderate capacity and hydrophobicity, recommended for isocratic and gradient separations of polar amines such as alkanolamines,
Certificate of Analysis
National Institute of Standards & Technology Certificate of Analysis Standard Reference Material 870 Column Performance Test Mixture for Liquid Chromatography This Standard Reference Material (SRM) is
Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection
52 May/June 2012 Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection by Karen Rome and Allyson McIntyre, AstraZeneca, Macclesfield, SK10 2NA, UK Quantitative analysis
Analysis of Vegetable Oils by High Performance Liquid Chromatography
Analysis of Vegetable Oils by High Performance Liquid Chromatography Using Evaporative Light Scattering Detection and Normal Phase Eluents Andrew J. Aubin, Cecilia B. Mazza, Donald A. Trinite, and Patricia
Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry
Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry BY GHULAM A. SHABIR Introduction Methods Validation: Establishing documented evidence that provides a high
Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring
PO-CON1359E Ultra Fast UHPLC-LCMSMS Method Development in HPLC 2013 MASS-09 Anja Grüning 1 ; Brigitte Richrath 1 ; Klaus Bollig 2 ; Sven Vedder 1 ; Robert Ludwig 1 1 Shimadzu Europa GmbH, Duisburg, Germany;
Materials for Pharmaceutical Manufacturing
Materials for Pharmaceutical Manufacturing GRACE WHITEPAPER Vydac 150HC Purification Media Greater Loading Capacity and Resolution for Improved Productivity in Peptide Purification Technical Development:
CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY
CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY 9.1 POLICY This test method may be used to confirm the presence of zolpidem (ZOL), with diazepam-d 5 (DZP-d 5 ) internal standard, in
What is Eluent Generation?
What is Eluent Generation? Monika Verma Thermo Fisher Scientific, Sunnyvale, CA, USA White Paper 70607 Executive Summary Eluent generation is an electrolytic process that allows the production of high
IC-MS and LC-MS Determination of Ionic Liquids, Counterions, and Impurities
ICMS and LCMS Determination of Ionic Liquids, Counterions, and Impurities Leo Wang, Detlef Jensen, and William Schnute Dionex Corporation, Sunnyvale, CA, USA; Dionex Corporation, Olten, Switzerland INTRODUCTION
Purification of reaction mixtures using flash chromatography.
Purification of reaction mixtures using flash chromatography. This technical note details the use of ISOLUTE Flash chromatography columns for the purification of reaction mixtures. What is flash chromatography?
Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate
Cantaurus, Vol. 7, 5-8, May 1999 McPherson College Division of Science and Technology Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate Janet Bowen ABSTRACT Sulfate is used in
Tamsulosin Hydrochloride Capsules
. nal Revision Bulletin Official October 1, 2011 Tamsulosin 1 standard solution, and shake well. Centrifuge at 1500 rpm for 10 min, and use the supernatant, passing it if Tamsulosin Hydrochloride Capsules
Intergovernmental Group- on Tea 10 th Session New Dehli, 12-14 May 2010
ISO Standards for Tea Intergovernmental Group- on Tea 10 th Session New Dehli, 12-14 May 2010 Andrew Scott, Chairman ISO TC/34 SC 8 Tea 1 2 Tea Over 3 million tonnes produced In over 30 countries Providing
Separation of Peptides from Enzymatic Digestion on Different Acclaim Columns: A Comparative Study
Application Update Now sold under the Thermo Scientific brand Separation of Peptides from Enzymatic Digestion on Different claim Columns: A Comparative Study INTRODUCTION Separation of peptides which can
An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.
An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols. Jaap de Zeeuw, Ron Stricek and Gary Stidsen Restek Corp Bellefonte, USA To analyze basic compounds at
Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction
Advantages of Using Triple Quadrupole over Single Quadrupole Mass Spectrometry to Quantify and Identify the Presence of Pesticides in Water and Soil Samples André Schreiber AB SCIEX Concord, Ontario (Canada)
Cliquid Drug Screen & Quant Software for Routine Forensic Toxicology. great interest in forensic, toxicological and clinical research laboratories.
Application Note Cliquid Drug Screen & Quant Software A Fast and Sensitive LC/MS/MS Method for the Quantitation and Confirmation of 30 Benzodiazepines and Nonbenzodiazepine Hypnotics in Forensic Urine
Application Note. Determination of 17 AQC derivatized Amino acids in baby food samples. Summary. Introduction. Category Bio science, food Matrix
Application Note Determination of 17 AQC derivatized Amino acids in baby food samples Category Bio science, food Matrix Baby food Method UHPLC Keywords Proteinogenic amino acids, canonical amino acids,
HPLC Column Comparison Screening Study for Reversed Phase Columns
HPLC Column Comparison Screening Study for Reversed Phase Columns Carmen T. Santasania, Eric M. Snyder, Matilal Sarker, and Tracy L. Ascah Supelco, 595 North Harrison Road, Bellefonte, PA 16823, USA T403058
Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS
Application Note: 446 Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS Jonathan McNally and Michael Belford, Thermo Fisher Scientific, San Jose, CA James Kapron, Thermo Fisher Scientific,
Monoclonal Antibody Fragment Separation and Characterization Using Size Exclusion Chromatography Coupled with Mass Spectrometry
Monoclonal ntibody Fragment Separation and haracterization Using Size Exclusion hromatography oupled with Mass Spectrometry uthors Haiying hen Katherine McLaughlin Sepax Technologies, Inc. 5 Innovation
Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS
Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS Stephen Lock 1 and Matthew Noestheden 2 1 AB SCIEX Warrington, Cheshire (UK), 2 AB SCIEX Concord, Ontario (Canada) Overview A rapid,
Solid Core Technical Compendium
150-C4 150-C18 Phenyl-Hexyl XL-C18 PFP 150-Amide-HILIC C0 Urea-HILIC Phenyl-X HILIC Polar Premium C8 XL-C8 aq C18 RP-MS Solid Core Technical Compendium Want fast, high-resolution separations, plus a range
Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants
Metabolomic Profiling of Accurate Mass LC- Data to Identify Unexpected Environmental Pollutants André Schreiber 1, David Cox 1, Nadia Pace 1, Christopher Borton 2 1 AB SCIEX, Concord, ntario, Canada; 2
SUCRALOSE. White to off-white, practically odourless crystalline powder
SUCRALOSE Prepared at the 41st JECFA (1993), published in FNP 52 Add 2 (1993). Metals and arsenic specifications revised at the 63rd JECFA (2004). An ADI of 0-15 mg/kg bw was established at the 37th JECFA
Appendix 5 Overview of requirements in English
Appendix 5 Overview of requirements in English This document is a translation of Appendix 4 (Bilag 4) section 2. This translation is meant as a service for the bidder and in case of any differences between
Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs
Thermo Scientific Prelude SPLC System FPO Making LC/MS accessible to clinical research and toxicology labs Specifically designed to make the power of LC/MS accessible Analysis of target compounds in complex
Environmental Analysis Using the ICS-3000 Ion Chromatography System
Environmental Analysis Using the ICS- Ion Chromatography System Ion chromatography (IC) is well established as a routine method for the analysis of ionic analytes in environmental samples. IC has been
MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process
- Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process Save Hours in Sample Preparation Reduce the time to prepare and inject samples
A Guide to the Analysis and Purification of Proteins and Peptides by Reversed-Phase HPLC
A Guide to the Analysis and Purification of Proteins and Peptides by Reversed-Phase HPLC HPLC Columns David Carr Your decision has lasting effects. Choose wisely. HPLC Columns Ultra Inert Base-Deactivated
Solid Phase Extraction Products PAGE: 1. Introduction of Solid Phase Extraction (SPE) Why Choose Nano-Micro Tech SPE
Solid Phase Extraction Products PAGE: 1 Introduction of Solid Phase Extraction (SPE) SPE has been used increasingly in chemical analysis and purification broadly, and become the most popular technology
Sample Preparation Using Solid Phase Extraction
Sample Preparation Using Solid Phase Extraction Dr. Shulamit Levin Based on: Yung-Fong (Henry) Cheng Waters Corporation 34 Maple Street Milford, MA 0757 Present at EAS'98 Workshop Troubleshooting of Sample
ABRF 2004 Poster# P55-S Displacement Chromatography Effects Can Cause Highly Selective Sampling of Peptides During Solid Phase Extraction Cleanup
ABRF 2004 Poster# P55-S Displacement Chromatography Effects Can Cause Highly Selective Sampling of Peptides During Solid Phase Extraction Cleanup by Andrew J. Alpert PolyLC Inc./ 9151 Rumsey Road, ste.
How To Test For Contamination In Large Volume Water
Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples Keywords Application Note ENV0212 This collaboration study was performed
Hydrophilic-Interaction Chromatography (HILIC) for LC-MS/MS Analysis of Monoamine Neurotransmitters using XBridge BEH Amide XP Columns
Hydrophilic-Interaction Chromatography (HILIC) for LC-MS/MS Analysis of Monoamine Neurotransmitters using XBridge BEH Amide XP Columns Jonathan P. Danaceau, Kenneth J. Fountain, and Erin E. Chambers Waters
Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS
Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS UCT Part Numbers: ECQUEU750CT-MP - QuEChERS, Mylar packs containing 4 g magnesium sulfate, 1 g sodium chloride, 0.5 g sodium citrate dibasic
[ Care and Use Manual ]
ACQUITY UPLC CSH Columns Contents I. Getting started a. Column Connectors b. Column Installation c. Column Equilibration d. ecord Installation e. Initial Column Efficiency Determination f. VanGuard Pre-Columns
ß-CYCLODEXTRIN SYNONYMS
ß-CYCLODEXTRIN Prepared at the 44th JECFA (1995), published in FNP 52 Add 3 (1995) superseding specifications prepared at the 41st JECFA (1993), published in FNP 52 Add 2 (1993). Metals and arsenic specifications
Vitamin C quantification using reversed-phase ion-pairing HPLC
Vitamin C quantification using reversed-phase ion-pairing HPLC Thomas Grindberg and Kristy Williams Department of Chemistry, Concordia College, 901 8 th St S, Moorhead, MN 56562 Abstract Vitamin C, an
Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection
Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection Application Note 1097 Liu Qian, Zheng Hongguo and
Affi-Prep Protein A Matrix Instruction Manual
Affi-Prep Protein A Matrix Instruction Manual Catalog Numbers 156-0005 156-0006 Bio-Rad Laboratories, 2000 Alfred Nobel Dr., Hercules, CA 94547 LIT-230 Rev B Table of Contents Section 1 Introduction...1
ERDOSTEINE - MONOGRAPH.
STRUCTURAL FORMULA (±1S-(2-[N-3-(2-oxotetrahydro thienyl)]acetamido)-thioglycolic acid) C 8 H 11 NO 4 S 2 M.W. = 249.307 DESCRIPTION Color : White to ivory white Appearance : Microcrystalline powder SOLUBILITY
Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)
Method OIV-MA-AS313-22 Type II method Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008) 1. Introduction
Strength in Technology HPLC COLUMNS. Product Guide
Strength in Technology HPLC COLUMNS Product Guide [ m V ] Cefadroxil 3 5 0 3 0 0 UniverSil C18 250x4.6mm 5µm Cefachlor Surface Area - 175m 2 /g 2 5 0 Pore Size - 140Å Voltage 2 0 0 Cefradine % Carbon -
Determination of Fat in Dried Milk Products Using Accelerated Solvent Extraction (ASE)
Application Note 340 Determination of Fat in Dried Milk Products INTRODUCTION Many extraction techniques for the determination of fat in food are labor-intensive or require long extraction times. The Roese-Gottlieb
Pipette Tips PACKARD BIOSCIENCE MultiPROBE II COMPATIBLE
User Guide for Reversed-Phase Pipette Tips PACKARD BIOSCIENCE MultiPROBE II COMPATIBLE Notice The information in this document is subject to change without notice and should not be construed as a commitment
HPLC Column Classification
Vol. 31(2) [Mar. Apr. 2005] of the USPC or the USP Council of Experts 637 HPLC Column Classification Brian Bidlingmeyer, * Agilent; Chung Chow Chan, { Eli Lilly and Company; Patrick Fastino, { FDA; Richard
Introduction. Methods. Sample Processing
PO-CON1656 High-sensitivity, high-throughput quantitation of catecholamines and metanephrine in plasma by automated WCX-SP coupled to LC/MS/MS for clinical research ASMS 2016 MP-080 Ichiro HIRANO 1, Atsuhiko
Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software
Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software Frank Tontala, Thermo Fisher Scientific, Germering, Germany Technical Note 708 Key Words Chromeleon Chromatography Data System,
Quantitative Analysis of Explosives in Surface Water Comparing Off-Line Solid Phase Extraction and Direct Injection LC/MS/MS
Application note Explosives by Direct Injection LC/MS/MS Quantitative Analysis of Explosives in Surface Water Comparing Off-Line Solid Phase Extraction and Direct Injection LC/MS/MS API 5000 LC/MS/MS System
SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY
CHAPTER 5 SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY CHAPTER 5 Simultaneous determination of Telmisartan
Implementing New USP Chapters for Analytical Method Validation
Implementing New USP Chapters for Analytical Method Validation March 2010 Ludwig Huber Fax.: +49 7243 602 501 E-mail: [email protected] Today s Agenda Handling Method Changes vs. Adjustments
Analyzing Small Molecules by EI and GC-MS. July 2014
Analyzing Small Molecules by EI and GC-MS July 2014 Samples Appropriate for GC-MS Volatile and semi-volatile organic compounds Rule of thumb,
A New QuEChERS Dispersive SPE Material and Method for Analysis of Veterinary Drug Residue by LC-MS-MS
A New QuEChERS Dispersive SPE Material and Method for Analysis of Veterinary Drug Residue by LC-MS-MS Olga Shimelis, Michael Ye, and Len Sidisky Supelco, Div. of Sigma-Aldrich, Bellefonte, PA 16823 USA
Contents. List of Contributors XIII The structure of The HPLC-Expert" Preface XVII
V List of Contributors XIII The structure of The HPLC-Expert" Preface XVII XV 1 LC/MS Coupling 1 1.1 State of the Art in LC/MS 1 Oliver Schmitz 1.1.1 Introduction 1 1.1.2 Ionization Methods at Atmospheric
Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder
Lecture Chromo-3: Gas Chromatography CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder Outline Introduction Instrument overview Carrier gas Sample
Determination of Tetracycline Antibiotics in Milk Using a Simple Strong Cation-Exchange SPE Cleanup Procedure and LC-MS/MS Analysis
Determination of Tetracycline Antibiotics in Milk Using a Simple Strong Cation-Exchange SPE Cleanup Procedure and LC-MS/MS Analysis UCT Product Numbers: CSDAU26: 2mg / 6mL SPE cartridge SLDA1ID21-3UM:
Electrospray Ion Trap Mass Spectrometry. Introduction
Electrospray Ion Source Electrospray Ion Trap Mass Spectrometry Introduction The key to using MS for solutions is the ability to transfer your analytes into the vacuum of the mass spectrometer as ionic
Henry Shion, Robert Birdsall, Steve Cubbedge, and Weibin Chen Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS
Development of Integrated Informatics Workflows for the Automated Assessment of Comparability for Antibody Drug Conjugates (ADCs) Using LC-UV and LC-UV/MS Henry Shion, Robert Birdsall, Steve Cubbedge,
Determination of Caffeine in Beverages HPLC-1
Determination of in s HPLC-1 Introduction This experiment provides an introduction to the application of High Performance Liquid Chromatography (HPLC) to the solution of complex analytical problems. Cola