Systems Ventilation Solutions
|
|
|
- Ashlynn Dickerson
- 9 years ago
- Views:
Transcription
1 Systems Ventilation Solutions
2 2
3 Contents Introduction What are Systems Product Selector MEV System Solutions Xplus 2 - EC ow Energy Multi-point Domestic and Commercial Ventilation System Xplus 250 / 400 DC 8CV Constant Volume Multi-point Extract MEV Eight Selectable Speeds Xplus 2 (AC) Multi-point Domestic and Commercial Ventilation System Xplus (AC) Multi-point Domestic and Commercial Ventilation System MVHR System Solutions Xcell 150QV / QVW Mechanical Ventilation with Heat Recovery Xcell 150U EC BP with summer bypass Wholehouse Heat Recovery Unit for Smaller Dwellings Xcell 200QV / QVW Vertical Mechanical Ventilation with Heat Recovery Xcell 300QV / QVW / QVI Mechanical Ventilation with Heat Recovery and Summer Bypass Xcell 350V EC BP Mechanical Ventilation with Heat Recovery and Summer Bypass Xcell 400QV / QVW / QVI Mechanical Ventilation with Heat Recovery and Summer Bypass Xcell 150 / 150R Horizontal Hideaway Heat Recovery Unit MVHR Xcell 200 / 200R / 200BP / 200RBP Horizontal Hideaway Heat Recovery Unit Xcell 600BP HE EC Horizontal ow Profile Heat Recovery Units Xcell 600 / 600BP Horizontal Hideaway Heat Recovery Unit Xcell 1000 BP HE EC Horizontal ow Profile Heat Recovery High Efficiency Units Xcell 1000 / 1000BP Horizontal ow Profile Heat Recovery Units Xcell 1500BP / 2000BP Horizontal ow Profile Heat Recovery Units Decentralised System Ventilation Premier Ultra DC2 & DC3 Fan Range Decentralised Extract System Premier Ultra CF20/40T CV Fan Range Decentralised Extract System EverDri Ultra DC Positive Pressure Ventilation ovolt XHR150 Safety Extra ow Voltage (SEV), Single Room Heat Recovery Ventilator AutoFlow Passive Air-Input Units Sensors and Switches Domestic Controls for Xplus 64 Domestic Controls for Xcell 65 Commercial Controls for Xcell System X Wholehouse Heat Recovery Ducting Kits Ducting Profile 150 Insulated Foam Circular System 70 Circular Rigid Plastic Insulated & Un-insulated 71 Flexible Ducting 72 Profile 25M / Profile 29 Ducting Metal / Plastic Flat Ducting Systems 73 for Premier Single Point Extraction Profile 54 / 60 / 90 Ducting Plastic Flat Ducting Systems For MEV & MVHR Ducting Extract & Input Grilles 76 Output Terminals Wiring Diagrams
4 System ventilation saving energy, saving money, saving the world ew building techniques, new building regulations and new consumer demands - all of them based on the need to reduce carbon emissions and heating bills - are driving rapid changes in ventilation technology. The concept of system ventilation is allowing architects, specifiers, builders and heating professionals to respond to these needs. ew homes are increasingly air tight. The latest revision of Part of the Building Regulations introduced lower limits on building permeability in 2010 and will require further reductions in 2013 and then again in The aim is to retain heat within the home, cutting energy losses and fuel bills as well as reducing CO 2 emissions. Yet air exchange is essential for the health and well-being of the occupants and for the building itself. An average family of four can release around 15 litres of moisture into the air every day. If the ventilation in the house is not sufficient to deal with this, condensation can build up - leading to problems such as streaming windows, peeling wallpaper and mould growth. These damp and moist conditions can create ideal breeding grounds for dust mites which are known to aggravate health problems such as asthma and other bronchial complaints. In extreme conditions, the damp can affect the structure of the building. Ventilation is therefore essential - not only to control condensation but to remove odours and atmospheric pollutants and to keep the air fresh. Unplanned and uncontrolled air exchange is precisely what Part is designed to halt. Part F of the Building Regulations therefore sets standards for ventilation, air quality and the control of condensation. System ventilation, which takes a whole building approach to ventilation needs, is providing the answer to balancing the apparently competing demands of air-tightness and adequate air exchange. At the same time it is also making a contribution to reducing CO 2 emissions and cutting fuel bills. 4
5 fresh air pure and simple 5
6 What are Systems System ventilation Mechanical extraction ventilation (MEV) can give precise, controlled, air extraction. It can take moisture and polluted air from area such as toilets, bathrooms, kitchens and utility rooms and vent it to the external atmosphere. Depending upon the building design and system requirements it can feature either a single unit extracting internal air through ducts from a number of wet rooms or it can have a separate fan running at a faster continuous extract rate in several locations in the house. When mechanical ventilation is combined with heat recovery to give MVHR - mechanical ventilation with heat recovery - it also gives excellent energy conservation. As much as 90 per cent of the heat in the air being expelled from the building can be recovered to warm the fresh incoming air, with obvious benefits in terms of reduced energy demands and therefore lower fuel bills. Typically fuel bills lower by 5% and up to 10% on E.S.T. Best Practice (3 air tightness). Xpelair (AEP) offer and recommend system design services to provide efficient functional designs prior to installation. Research and development System ventilation is the answer to today s ventilation requirements - and tomorrow s as well. The Government is committed to all new homes being zero carbon by 2016 and at Xpelair we are playing our part in meeting that commitment. We continue to invest in research and development to meet the rapidly changing needs both of our professional customers and, ultimately, of householders. Our focus is on delivering a healthy indoor climate with minimum cost, minimum energy use and the minimum impact on the global environment. 6
7 Xpelair, BRE and Appendix Q The environmental benefits of our MVHR systems have been recognised by the Building Research Establishment (BRE). Some of our latest products are listed on the BRE SAP Appendix Q website which promotes energy efficient ventilation products that offer benefits in SAP and DER (Dwelling Emission Rate) calculations. In the database on the website, individual products replace the normal/default settings for each ventilation option. Each product is tested to provide a specific fan power performance that can be used to calculate 'energy saving' which is re-entered into the SAP calculation process. The BRE s Appendix Q register and the EST Best Practice documents highlight the market s most efficient domestic ventilation products and Xpelair is delighted to be among them. 50 years of experience For more than 50 years the Xpelair name has been synonymous with fans and air movement. Over that time the company has continued to develop new products and new technologies to ensure the air we all breathe is clean, fresh and healthy. Today, the need to reduce carbon emissions has led us to take a leading role in the development of the MVHR market in the UK and beyond. In addition to offering an extensive product range we provide customers with first-class support services. As part of Applied Energy Products, which is also home to Redring and Creda Heating, we are backed by superb technical facilities. Our specification team can give expert pre-sales advice on product selection. A free design service is available from our application design department which can work from your plans to provide drawings including space heating, ventilation and water heating products. For after sales support we have both an in-house team that can offer advice over the phone and a team of service engineers for carrying out repairs and maintenance on site. 7
8 Product Selector Domestic & on Domestic ight Commercial Applications Kitchens Wet rooms Domestic Toilets Dwelling Size m Peak airflow m 3 /h Peak airflow l/s MEV Xplus AW Xplus 2EC 92498AG Xplus AW Xplus 250 DC 8CV 92290AW Xplus 400 DC 8CV 92100AW Products MVHR Appendix Q Xcell 150U EC BP 92392AW Xcell 350U EC BP (RH) 92393AW Xcell 350U EC BP (H) 92395AW Xcell 150QV 92420AW Xcell 150QVW 92461AW Xcell 150QV 96735AW Xcell 150QVW 96736AW Xcell 200QV 92461AW Xcell 200QVW 92462AW Xcell 200QV 96737AW Xcell 200QVW 96738AW Xcell 300QV 92463AW Xcell 300QVW 92464AW Xcell 300QVI 92465AW Xcell 300QV 92470AW Xcell 300QVW 92471AW Xcell 300QVI 92472AW Xcell 400QV 92475AW Xcell 400QVW 92476AW Xcell 400QVI 92478AW Xcell 400QV 92479AW Xcell 400QVW 92480AW Xcell 400QVI 92482AW MVHR Xcell AA Xcell 150R 92100AA Xcell 150V 92004AA Xcell AA Xcell 200R 91978AA Xcell 200BP 91979AA Xcell 200RBP 91980AA Xcell AA Xcell 600BP 92003AA Xcell 600 BP HE EC 92544AA Xcell 1000 (AC) 92563AW Xcell 1000 BP (AC) 92564AW Xcell 1000 BP HE EC 92545AA Xcell 1500 BP (AC) 92565AW Xcell 2000 BP (AC) 92462AW Based on Part F of the Building Regulations and CIBSE Guidelines. 8
9 Kitchens 1 on-domestic Wet rooms Toilets Dwelling Size m Peak airflow m 3 /h Peak airflow l/s
10 MEV System Solutions Mechanical Extract Ventilation (MEV) can comprise either a whole building central extract system or low energy extract fans in individual use rooms This system is designed for the simultaneous ventilation of separate areas in a house or building. Using a single energy efficient fan, the unit is located in the loft or airing cupboard, with ducts run to quietly remove pollutants at source from areas such as bathrooms, kitchens, utility rooms and WCs. Alternatively, individual trickle fans can be installed in the kitchen, bathrooms, showers and WCs to form an MEV system in refurbished properties. Atmosphere Discharge Dwelling Extract 10
11 fresh air pure and simple 11
12 Xplus 2 - EC ow Energy Multi-point Domestic and Commercial Ventilation System Key Features Extra long life Ultra EC motor 3 installer adjustable speed settings Up to six 125mm Ø extract spigot connections ong life motor external rotor motor for lower whole life cost 5 year Ultra EC motor guarantee (UK) To suit apartments and average family homes The Range The Xpelair Xplus 2 EC is a low energy centralised extraction system for dwellings. It removes the need for small individual ventilation products in the bathrooms, toilets and kitchens. The Product can be installed on a wall (typically in an airing cupboard), in the attic (typically on the gable end or floor), in an apartment ceiling or floor voids depending on the product having a low height profile. Xplus 2 EC has a highly energy efficient backward curved impeller and control functionality designed to reduce energy consumption. The extract speeds can be set by the installer to match the required Part F extract rates for the size and layout of the dwelling. Energy Guide Product Exhaust terminal configuration Fan power (Watts) Energy saving % KITCHE + Xplus 2 (AC) 3 additional wet rooms (37 l/s) 23.9 /A KITCHE + Xplus 2 EC 3 additional wet rooms (37 l/s)
13 Select the right setting for your application Product Selector Xplus 2 - EC Reference number 92498AG Motor type EC Maximum extract performance (FID, m 3 /h) 550 Maximum extract performance (m Maximum system pressure (Pa) 350 Power usage maximum (W) V AC 50-60Hz 79 Specific fan power (average) 0.21 Speeds 3 Speed control type Selected 240V inputs and on-board variability oise (db(a)@3m) Speed 1/2/3 20.6/35.2/47.1 umber of intake spigots 6 umber of exhaust spigots 1 Spigot diameter (mm) 125 Colour Green Installation orientation Vertical or horizontal Body material Plastic Weight (kg) 3.4kg Guarantee (years, UK) 5 Kg carbon saving per annum 30* *Based on comparison with a standard AC MEV unit on a 79m 2 semi detached house, gas heated, build 2006 using SAP 2005 software using best practice (3) tightness. Performance Static Pressure in Pa Trickle Speed Band S1 & S2 Speed Band Airflow m 3 /h Trickle Maximum Speed S1 & S2 Maximum Airflow (C.F.M.) Dimensions (mm) Static Resistance w.g Performance Table (m 3 /hr) Pa Trickle Medium/High Speed Speed (fully adjustable) (fully adjustable) SAP Appendix Q Guide Exhaust terminal configuration KITCHE + 1 additional wet room Fan speed setting Specific fan power (W/l/s) Energy Saving Trust Best Practice performance compliant 100% Variable 0.21 Yes KITCHE + 2 additional wet rooms 100% Variable 0.19 Yes KITCHE + 3 additional wet rooms 100% Variable 0.19 Yes 510 KITCHE + 4 additional wet rooms KITCHE + 5 additional wet rooms 100% Variable 0.21 Yes 100% Variable 0.24 Yes 480 KITCHE + 6 additional wet rooms 100% Variable 0.27 Yes Controller Options: Model COS 3SP-SW XPIRA DT20B XRH AQS MOS 2 Speed Switch 3 Speed Switch PIR Sensor Time Delay Unit Remote Humidistat Air Quality Sensor Manual Override Switch Reference number 90108AW 91457AA 21871AA 21850AW 21856AW 92097AW 90199AW Xplus 2 (EC) 13
14 Xplus 250 / 400 DC 8CV Constant Volume Multi-point Extract MEV Eight Selectable Speeds Key Features UltraDC technology for low energy use Extra long life motor for lower whole life costs 8 externally selectable speeds at installation to provide installed continuous extract performances for the requirements of Part F1 Constant volume feature means extract performance remains consistent irrespective of system resistance up to 300Pa 5 year UK Carbonite guarantee for peace of mind The Range Two Xplus multispeed models with constant volume UltraDC technology. Energy efficient and long lasting. Xpelair Xplus UltraDC 8CV is designed with installer selectable settings to satisfy Part F1 installed performances for continuous ventilation in domestic dwellings. The trickle speed is selectable at installation, based on the sum of the continuous extract rate requirements from table 1.1a of Part F1. Xplus offers constant volume centrifugal performance with a long life UltraDC motor. The installer selects the performance required - Xplus selects the speed necessary to meet the performance based on the system resistance. This ensures a constant extract performance and lower energy use than AC equivalents. Three 125mm input spigots are provided for connection to Xpelair Xflex ducting. Xpelair Y pieces can be used for further branch ducts. 125mm RegulAir ceiling spigots with RegulAir factory set extract grilles ensure the correct extract rate from bathrooms and toilets without system balancing. A louvred grille with filtered inlet is used in the kitchen. The built-in boost option allows the installer to select advanced sensors: humidity control, adjustable overrun timer, passive infrared sensor or Air Quality Sensor (AQS) to provide boost override. 14
15 Select the right setting for your application Product Selector Xplus 250 DC Xplus 400 DC Reference number 92290AW 92100AW UltraDC long life motor Yes Yes Constant volume Yes Yes Maximum extract performance (FID, m 3 /h) Maximum extract performance (m Maximum system pressure (Pa) Power usage (W) Speed 1/2/3/4/5/6/7/8 3.5/4.2/5/5.5/9.5/11.3/12.2/ /26.3/28/30.8/49.1/60.3/65.6/ V AC 50-60Hz Specific fan power (average W/l/s) 0.4 /A oise (db(a)@3m) Speed 1/2/3/4/5/6/7/8 26/31.2/32.7/36/40.2/43.1/45.2/ /50.5/50.7/50.6/50.7/50.8/50.9/50.9 Boost override speed Increases performance by one speed Increases performance by one speed Outlet spigot Ø Ø125mm Ø125mm Inlet spigots 125mm 3 3 Colour Black Black Body material Plastic Plastic Guarantee (years, UK) 5 5 Kg carbon saving 16* 70* *Based on comparison with a standard AC MEV unit on a 79m 2 semi detached house, gas heated, build 2006 using SAP 2005 software using best practice (3) tightness. Performance Xplus 250 DC Volume (C.F.M.) Static Pressure in Pa Flow rate in l/s w.g. Performance Table (m 3 /hr) Xplus 250 DC Xplus 400 DC Speeds m 3 /h m 3 /h m 3 /h m 3 /h SAP Appendix Q Guide (Xplus 250 DC only) Exhaust terminal configuration Fan speed setting Specific fan power (W/l/s) Energy Saving Trust Best Practice performance complient Flow rate in m 3 /h KITCHE + 1 additional wet room Yes Xplus 400 DC Volume (C.F.M.) KITCHE + 2 additional wet rooms Yes Static Pressure in Pa Flow rate in l/s w.g. KITCHE + 3 additional wet rooms KITCHE + 4 additional wet rooms Dimensions (mm) OUT Yes Yes OUT Flow rate in m 3 /h Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 Speed 7 Speed Controller Options: Model COS XPIRA DT20B XRH AQS MOS 2 Speed Switch PIR Sensor Time Delay Unit Remote Humidistat Air Quality Sensor Manual Override Switch Reference number 90108AW 21871AA 21850AW 21856AW 92097AW 90199AW Xplus 250 & 400 DC 8CV 15
16 Xplus 2 (AC) Multi-point Domestic and Commercial Ventilation System Key Features 190mm low profile design 4 installer adjustable speed settings 6 125mm Ø extract spigot positions External rotor motor Moulded high performance scroll Integral fixing points Suitable for temperatures up to 50 C 100% recyclable The Range The Xplus 2 is a high performing central extract system designed to continuously extract stale, moist air from all wet areas, such as kitchens and bathrooms. The unit is primarily used in domestic applications but can also be used for commercial applications, where continuous extract is required. The multi-spigot design offers the installer greater flexibility when choosing where to site the unit and also due to the spigot configuration, allows any ducting to be connected from any direction, therefore reducing airflow restriction and noise. The unit is suitable for either horizontal or vertical installation. The Xplus 2 has 1-125mm Ø discharge spigot to atmosphere and up to 6-125mm Ø spigots from the dwelling, depending on the total volume required. 3 blanking plates are also supplied. Xpelair accessories such as Profile 60 rectangular flat duct together with 125mm Ø rigid and flexible insulated/uninsulated ducting can be used in conjunction with the Xplus 2 unit to provide a complete ventilation system. 16
17 Select the right setting for your application Product Selector Xplus 2 Reference number 92430AW Motor type AC Maximum extract performance (FID, m 3 /h) 471 Maximum extract performance (m Maximum system pressure (Pa) 400 Power usage maximum (W) V AC 50-60Hz Speed 1/2/3/4 13.4/23.9/35/58.2 Specific fan power (W/l/s) Speed 1/3 0.31/0.44 Speeds 4 Speed control type Capacitor loading by selected value oise (db(a)@3m) Speed 1/2/3/4 20.1/30.7/37.1/45.1 umber of intake spigots 6 umber of exhaust spigots 1 Spigot diameter (mm) 125 Colour Blue Installation orientation Vertical or horizontal Body material Plastic Weight (kg) 4.95kg Guarantee (years, UK) 2 Performance Performance Table (m 3 /hr) Static Pressure in Pa Airflow (C.F.M.) Static Resistance w.g Pa Speed 1 Speed 2 Speed 3 Speed Speed 1 Speed 2 Speed 3 Speed 4 Airflow m 3 /h 0.0 Dimensions (mm) Energy Guide Product 510 Exhaust terminal configuration Fan power (Watts) KITCHE + Xplus 2 (AC) 3 additional wet rooms (37 l/s) 23.9 Energy saving % /A 480 Controller Options: Model COS 3SP-SW XPIRA DT20B XIC1 XRH AQS MOS 2 Speed Switch 3 Speed Switch PIR Sensor Time Delay Unit Speed Controller Remote Humidistat Air Quality Sensor Manual Override Switch Reference number 90108AW 91457AA 21871AA 21850AW 21858AW 21856AW 92097AW 90199AW Xplus 2 (AC) 17
18 Xplus (AC) Multi-point Domestic and Commercial Ventilation System Key Features Higher performance Xplus 2 190mm low profile design 6 125mm Ø extract spigot positions External rotor motor Moulded high performance scroll Integral fixing points Suitable for temperatures up to 50 C 100% recyclable The Range The Xplus is a high performing central extract system designed to continuously extract stale, moist air from all wet areas, such as kitchens and bathrooms in villas and commercial wet rooms. The unit is primarily used in domestic applications but can also be used for commercial applications, where continuous extract is required. The multi-spigot design offers the installer greater flexibility when choosing where to site the unit and also due to the spigot configuration, allows any ducting to be connected from any direction, therefore reducing airflow restriction and noise. The unit is suitable for either horizontal or vertical installation. The Xplus has 1-125mm Ø discharge spigot to atmosphere and up to 6-125mm Ø spigots from the dwelling, depending on the total volume required. 3 blanking plates are also supplied. Xpelair accessories such as Profile 60 rectangular flat duct together with 125mm Ø rigid and flexible insulated/uninsulated ducting can be used in conjunction with the Xplus unit to provide a complete ventilation system. 18
19 Select the right setting for your application Product Selector Xplus Reference number 92483AW Motor type AC Maximum extract performance (FID, m 3 /h) 483 Maximum extract performance (m Maximum system pressure (Pa) 400 Power usage maximum (W) V AC 50-60Hz Speed 1/2/3 24.7/36.8/97.8 Specific fan power (FID W/l/s) Speed 1/3 0.54/0.72 Speeds 3 Speed control type Capacitor loading by selected value oise (db(a)@3m) Speed 1/2/3 23.9/27.1/47.3 umber of intake spigots 6 umber of exhaust spigots 1 Spigot diameter (mm) 125 Colour Blue Installation orientation Vertical or horizontal Body material Plastic Weight (kg) 4.95kg Guarantee (years, UK) 2 Performance Static Pressure in Pa Speed 1 Speed 2 Speed 3 Airflow m 3 /h Performance Table ow Medium High ow Medium High Speed Speed Speed Speed Speed Speed Wg CFM CFM CFM Pa CFM CFM CFM Dimensions (mm) Airflow (C.F.M.) Static Resistance w.g 480 Controller Options: Model COS 3SP-SW XPIRA DT20B XIC1 XRH AQS MOS 2 Speed Switch 3 Speed Switch PIR Sensor Time Delay Unit Speed Controller Remote Humidistat Air Quality Sensor Manual Override Switch Reference number 90108AW 91457AA 21871AA 21850AW 21858AW 21856AW 92097AW 90199AW Xplus (AC) 19
20 MVHR System Solutions The most effective solution that meets the requirements of both Part F and Part is Mechanical Ventilation with Heat Recovery (MVHR). This system continuously extracts polluted air from kitchens, bathrooms, WCs and utility rooms. The polluted air is passed through a heat exchanger that has the ability to recover as much as 90% of the heat from a ventilated room, which is used to pre-warm incoming fresh air. A key benefit of Heat Recovery ventilation is it is the perfect solution to noise ingress issues as no window trickle ventilation is required. Overall, Heat Recovery ventilation ensures a drier, warmer and more comfortable home or commercial environment. To complement this, condensation issues are virtually eliminated along with an environment where hazardous pollutants might cause health issues. Typically fuel bills lower by 5% and up to 10% on E.S.T. Best Practice (3 air tightness). Carbon emissions reduce by 5-15% on current SAP 2005 and SBEM building software. Atmosphere Discharge Dwelling Supply Dwelling Extract Atmosphere Intake 20
21 fresh air pure and simple 21
22 Xcell 150QV / QVW Mechanical Ventilation with Heat Recovery Key Features Ultra EC technology for low energy use High efficiency counterflow cell with up to 90% efficiency EPP high structural integral body G4 filters The unit is supplied with a 1m length of 20mm Ø (O/D) plastic condensate tubing SAP Appendix Q isted Ultra EC technology for low energy use The Range The ew Xpelair Xcell 150QV is one of a range of a new generation of Carbonite energy efficient Mechanical Ventilation units with Heat Recovery (MVHR) designed for modern tight buildings. It is ideal for apartments and houses, is suitable for handed installations and has a standard 600mm width. The Xcell 150QV has a lightweight EPP construction and can be wall or loft mounted. The design combines a highly insulated EPP structural foam body with four 125mm Ø extract spigot connections with barbed connections and has a 90% energy efficient heat exchanger, EC ultra low energy multi-speed external rotor motors and long life G4 filters. Inspection of the filters is easily achieved by removal of the rotating, easy fit access panel without switching the unit off. Xcell 150QV / QVW Atmosphere Intake Dwelling Extract Atmosphere Discharge Dwelling Supply 4-125mm Ø Spigots 22
23 Select the right setting for your application Product Selector Xcell 150QV Xcell 150QV Xcell 150QVW Xcell 150QVW Right Hand eft Hand Right Hand eft Hand Reference number 92420AW 96735AW 92460AW 96736AW Motor type EC EC EC EC Maximum supply / extract performance (FID, m 3 /h) Maximum supply / extract performance (m Maximum system pressure (Pa) Power usage maximum (W) V AC 50-60Hz Specific fan power (average W/l/s) 0.74* 0.74* 0.74* 0.74* Efficiency (%) Speeds Speed control type Remote variable DC Remote variable DC Remote variable DC Remote variable DC oise (db(a)@3m) ow/medium/max 26.1/40.9/ /40.9/ /40.9/ /40.9/49.1 Spigot diameter (mm) Installation orientation Vertical Vertical Vertical Vertical Body material Plastic Plastic Plastic Plastic Weight (kg) 17.5kg 17.5kg 17.5kg 17.5kg Guarantee (years, UK) Kg carbon saving 160** 160** 160** 160** *Specific fan power is subject to system design resistance. **Based on comparison with 3 standard intermittent AC fans on a 79m 2 semi detached house, gas heated, build 2006 using SAP 2005 software using best practice (3) tightness. Performance Static Pressure in Pa Airflow (C.F.M.) Performance Band Static Resistance w.g Performance Table Pa Max Speed m 3 /h Airflow m 3 /h Speed 1 Speed Dimensions (mm) SAP Appendix Q Guide S.F.P (W/l/s) Heat recovery efficiency E.S.T. Best Practice performance compliant 4-Ø125 Spigots KITCHE + 1 additional wet room 100% Variable % Yes 595 KITCHE + 2 additional wet rooms 100% Variable % Yes KITCHE + 3 additional wet rooms 100% Variable % Yes 425 Side View 600 Front View KITCHE + 4 additional wet rooms 100% Variable % Yes Controller Options: Model MS2 Q3SP QC02 QHS 2 Speed Manual Controller Automatic 3 Speed Controller C0 2 Sensor Humidity Sensor Reference number 23513AW 96005AA 96003AA 96009AA Xcell 150QV/QV Xcell 150QVW/QVW 23
24 Xcell 150U EC BP with summer bypass Wholehouse Heat Recovery Unit for Smaller Dwellings Key Features Appendix Q recognised for SAP calculation improvements UltraEC technology for low energy use Extra long life motor for lower whole life costs Summer bypass provides free cooling for summer evenings Up to 88% heat recovery efficiency 5 year UK only Carbonite guarantee for peace of mind The unit has a 1 1 / 4 Ø condensate connection The Range The Xcell 150U EC BP is ideal for new residential flats and apartments. A key feature is its slim, compact case design for mounting vertically in an airing cupboard or utility room. At the heart of the Xcell 150U EC BP is the Xcell counter flow heat exchanger cell with a high heat recovery rate of up to 92%. For the user this heat saved means lower energy use. The latest Xpelair UltraEC (Electronically Commutated) motor technology further ensures that energy running costs are also a fraction of AC motor equivalents. The Xcell unit performance is set up digitally at installation to exactly match the dwelling size and layout. The constant volume long-life motors then maintain the chosen balance between intake and extract rates. A three speed switch provides a choice of daytime running, reduced night time performance and boost speed. During the summer months an automatic summer bypass facility provides free cooling in the winter. Xcell 150U EC BP Atmosphere Intake Atmosphere Discharge 4-125mm Ø Spigots Dwelling Extract Dwelling Supply 24
25 Select the right setting for your application Product Selector Xcell 150U EC BP Reference number 92392AW Summer bypass Yes (automatic) Motor type EC Maximum supply / extract performance (FID, m 3 /h) 165 Maximum supply / extract performance (m Maximum system pressure (Pa) 155 Efficiency (%) 88 Speeds selected during installation Between % in 1% steps Speed control type Preset onboard Typical performance (m 3 /h) Speed 1/2/3 75/95/155 oise (db(a)@3m) Speed 1/2/3 35/44/52 Power usage (W) V AC 50-60Hz Speed 1/2/3 27/39/106 Specific fan power (W/l/s) 1.1 Installation orientation Vertical Body material Plastic Spigot diameter (mm) 125 Colour Grey Unit only weight (kg) 28 UK only Carbonite guarantee (years) 5 Kg carbon saving (per year) 100* *Based on comparison with 3 standard intermittent AC fans on a 79m 2 semi detached house, gas heated, build 2006 using SAP 2005 software using best practice (3) tightness. Performance Airflow (C.F.M.) Performance Table Static Pressure in Pa Performance Band Static Resistance w.g Pa Max Speed m 3 /h Airflow m /h Speed 1 (holiday/absent) Speed 2 (normal) Speed 3 (boost) C.F.M. Cubic feet per minute In. wg Inches water gauge 0 SAP Appendix Q Guide KITCHE + 1 additional wet room KITCHE + 2 additional wet rooms S.F.P (W/l/s) Heat recovery efficiency 100% Variable % 100% Variable % KITCHE + 3 additional wet rooms 100% Variable % Dimensions (mm) KITCHE + 4 additional wet rooms 100% Variable % KITCHE + 5 additional wet rooms 100% Variable % Controller Model Reference number Xcell 150U EC BP 3SP 3 Speed Switch 92396AA 25
26 Xcell 200QV / QVW Vertical Mechanical Ventilation with Heat Recovery Key Features Ultra EC technology for low energy use High efficiency counterflow cell with up to 90% efficiency EPP high structural integral body G4 filters The unit is supplied with a 1m length of 20mm Ø (O/D) plastic condensate tubing SAP Appendix Q isted Ultra EC technology for low energy use The Range The ew Xpelair Xcell 200QV is one of a range of a new generation of Carbonite energy efficient Mechanical Ventilation units with Heat Recovery (MVHR) designed for modern tight buildings. It is ideal for apartments and houses, is suitable for handed installations and has a standard 600mm width. The Xcell 200QV has a lightweight EPP construction and can be wall or loft mounted. The design combines a highly insulated EPP structural foam body with four 125mm Ø extract spigot connections with barbed connections and has a 90% energy efficient heat exchanger, EC ultra low energy multi-speed external rotor motors and long life G4 filters. Inspection of the filters is easily achieved by removal of the rotating, easy fit access panel without switching the unit off. Xcell 200QV Atmosphere Intake Dwelling Extract Atmosphere Discharge Dwelling Supply 4-125mm Ø Spigots 26
27 Select the right setting for your application Product Selector Xcell 200QV Xcell 200QV Xcell 200QVW Xcell 200QVW Right Hand eft Hand Right Hand eft Hand Reference number 92461AW 96737AW 92462AW 96738AW Motor type EC EC EC EC Maximum supply / extract performance (FID, m 3 /h) Maximum supply / extract performance (m Maximum system pressure (Pa) Power usage maximum (W) V AC 50-60Hz Specific fan power (average W/l/s) 0.74* 0.74* 0.74* 0.74* Efficiency (%) Speeds Speed control type Remote variable DC Remote variable DC Remote variable DC Remote variable DC oise (db(a)@3m) ow/medium/max 26.1/40.9/ /40.9/ /40.9/ /40.9/49.1 Spigot diameter (mm) Colour White White White White Installation orientation Vertical Vertical Vertical Vertical Body material Plastic Plastic Plastic Plastic Weight (kg) 17.5kg 17.5kg 17.5kg 17.5kg Guarantee (years, UK) Kg carbon saving 160** 160** 160** 160** *Specific fan power is subject to system design resistance. **Based on comparison with 3 standard intermittent AC fans on a 79m 2 semi detached house, gas heated, build 2006 using SAP 2005 software using best practice (3) tightness. Performance Static Pressure in Pa Performance Band Airflow (C.F.M.) Dimensions (mm) Airflow m 3 /h SAP Appendix Q Guide KITCHE + 1 additional wet room Performance Table Pa Max Speed m 3 /h S.F.P (W/l/s) Heat recovery efficiency 100% Variable % E.S.T. Best Practice performance compliant Yes 4-Ø125 Spigots KITCHE + 2 additional wet rooms 100% Variable % Yes 595 KITCHE + 3 additional wet rooms 100% Variable % Yes KITCHE + 4 additional wet rooms 100% Variable % Yes 425 Side View 600 Front View KITCHE + 5 additional wet rooms 100% Variable % Yes Controller Options: Model MS2 Q3SP QC02 QHS 2 Speed Manual Controller Automatic 3 Speed Controller C0 2 Sensor Humidity Sensor Reference number 23513AW 96005AA 96003AA 96009AA Xcell 200QV/QV Xcell 200QVW/QVW 27
28 Xcell 300QV / QVW / QVI Mechanical Ventilation with Heat Recovery and Summer Bypass Key Features QVI/QVI includes summer bypass eft and right hand versions available for handed applications RF controllers available High efficiency counterflow heat recovery cell with up to 91% efficiency Powder coated stainless steel G4 Specification The unit is supplied with a 1m length 20mm Ø (O/D) plastic condensate tubing SAP Appendix Q isted 5 year guarantee The Range The new Xpelair Xcell 300QV is one of a new generation of Carbonite energy efficient Mechanical Ventilation units with Heat Recovery (MVHR) designed modern tight buildings. It is ideal for 3-5 bed houses and large apartments. The Xcell 300QV can be wall or loft mounted. The design combines a highly insulated EPP structural foam body with four 150mm Ø spigot connections, up to 91% energy efficient heat exchanger. UltraEC low energy multi-speed single inlet external rotor motors and long life G4 filters. The Xcell 300QV range will deliver a refreshed indoor environment day-in day-out whilst efficiently recovering up to 91% of the outgoing heat energy. The Xcell 300QV Range has been designed with easy user maintenance in mind, the filters can be accessed for inspection without the unit being electrically isolated. The stylish case can be occasionally wiped clean. Fresh air intake from atmosphere and dwelling extract filters (G4 Specification) are housed within the unit to filter the airstreams before they pass through the heat recovery cell. The filters are accessed through the easy turn access panel. Xcell 300QV Dwelling Extract Atmosphere Discharge Atmosphere Intake Dwelling Supply 4-150/160mm Ø Spigots 28
29 Select the right setting for your application Product Selector Xcell 300QV Xcell 300QVW Xcell 300QVI Xcell 300QV Xcell300QVW Xcell300QVI Right Hand Right Hand Right Hand eft Hand eft Hand eft Hand Reference number 92463AW 92464AW 92465AW 92470AW 92471AW 92472AW Maximum supply / extract performance (FID, m 3 /h) Maximum supply / extract performance (m 3 Maximum static pressure (Pa) Speeds Speed control type Remote DC Remote DC Remote DC Remote DC Remote DC Remote DC oise (db(a)@3m) Speed 1/2/3 29/34/44 29/34/44 29/34/44 29/34/44 29/34/44 29/34/44 Power usage (W) Speed 1/2/3 33/61/130 33/61/130 33/61/130 33/61/130 33/61/130 33/61/ V AC 50-60Hz Specific fan power (average W/l/s) Weight (kg) Guarantee (years) Kg carbon saving (per year) 1520* 1520* 1520* 1520* 1520* 1520* *Based on comparison with 3 standard intermittent AC fans on a 557m 2 detached 6 wet room house, gas heated, build 2006 using SAP 2005 software using best practice (3) tightness. Performance Static Pressure in Pa Volume (C.F.M.) Min Speed Max Speed Performance Band Airflow m 3 /h Static Resistance w.g Performance Table Pa Max Speed m 3 /h SAP Appendix Q Guide KITCHE + 1 additional wet room KITCHE + 2 additional wet rooms S.F.P (W/l/s) Heat recovery efficiency 100% Variable % 100% Variable % E.S.T. Best Practice performance compliant Yes Yes Dimensions (mm) KITCHE + 3 additional wet rooms 100% Variable % Yes 70 KITCHE + 4 additional wet rooms 100% Variable % Yes 660 KITCHE + 5 additional wet rooms 100% Variable % Yes KITCHE + 6 additional wet rooms 100% Variable % Yes KITCHE + 7 additional wet rooms 100% Variable % Yes Controller Options: Model MS2 Q3SP QC02 QHS QTS QRFT RF QRFT RF QSD 2 Speed Manual Automatic 3 Speed C02 Sensor Humidity Sensor Timer 3 Speed Transmitter Receiver Smoke Alarm Controller Controller Controller Controller Reference number 23513AW 96005AA 96003AA 96009AA 96004AA 96006AA 96007AA 96021AA Xcell 300QV Xcell 300QVW Xcell 300QVI Xcell 300QV Xcell 300QVW Xcell 300QVI 29
30 Xcell 350V EC BP Mechanical Ventilation with Heat Recovery and Summer Bypass Key Features Appendix Q recognised for SAP calculation improvements UltraEC technology for low energy use Extra long life motor for lower whole life costs Summer bypass provides free cooling for summer evenings Up to 93% heat recovery efficiency The unit is supplied with a 1m length 12mm Ø (O/D) plastic tubing 5 year UK only Carbonite guarantee for peace of mind The Range Mechanical ventilation with heat recovery (MVHR) is a whole house solution which silently provides constant background flow of fresh tempered air to the living spaces of a tight home whilst extracting condensation, smells and VOCs (volatile organic compounds) from kitchens, bathrooms, utility rooms and toilets. The Xpelair Xcell 350V EC BP is one of a new breed of high efficiency Carbonite MVHR units and with variable performance of up to 370m 3 /h, making it ideal for larger property applications. The ew Xcell 350V EC BP meets the requirements of the Building Regulations and is SAP Appendix Q recognised, with specific fan powers of only 0.71 W/l/s and benefits the energy saving conscious with a typical carbon saving of up to 1153kg per annum. At the heart of the Xcell 350V EC BP is the Xcell counter flow heat exchanger cell with an average heat recovery rate of up to 93%. For the user this heat saved means lower heating energy use. The latest Xpelair UltraEC (Electronically Commutated) motor technology further ensures that energy running costs are a fraction of AC motor equivalents. Dwelling Extract Xcell 350V EC BP Atmosphere Discharge Atmosphere Intake Dwelling Supply 4-160mm Ø Spigots 30
31 Select the right setting for your application Product Selector Xcell 350V EC BP Xcell 350V EC BP Right Hand eft Hand Reference number 92393AW 92395AW Summer bypass Yes (automatic) Yes (automatic) Motor type EC EC Appendix Q specific fan powers (W/l/s) Efficiency (%) Speed control type Onboard between % in 1% steps Onboard between % in 1% steps Maximum static pressure (Pa) Maximum supply / extract performance (m Typical performance (m 3 /h) low/medium/high 100/270/ /270/360 oise (db(a)@3m) low/medium/high 10/30/36 10/30/36 Power (W) V AC 50-60Hz low/medium/high 20/109/246 20/109/246 Installation orientation Vertical Vertical Body material Steel Steel Spigot diameter (mm) 160 (internal) 160 (internal) Colour Grey/turquoise Grey/turquoise Unit only weight (kg) UK only Carbonite guarantee (years) 5 5 Weight (kg) Kg carbon saving (per year) 1153* 1153* *Based on comparison with 3 standard intermittent AC fans on a 557m 2 detached 6 wet room house, gas heated, build 2006 using SAP 2005 software using best practice (3) tightness. Performance Static Pressure in Pa Volume (C.F.M.) W W W Speed band 3 230W Speed band 5 Speed band 4 243W In. wg Performance Table Pa Max Speed m 3 /h W 100 Speed band 2 220W Speed band 1 35% 50% 70% 90% 100% 22W 52W 120W Flow rate in m 3 /h C.F.M. Cubic feet per minute In. wg Inches water gauge 0 SAP Appendix Q Guide KITCHE + 1 additional wet room S.F.P (W/l/s) Heat recovery efficiency 100% Variable % E.S.T. Best Practice performance compliant Yes Dimensions (mm) KITCHE + 2 additional wet rooms 100% Variable % Yes KITCHE + 3 additional wet rooms 100% Variable % Yes KITCHE + 4 additional wet rooms 100% Variable % Yes KITCHE + 5 additional wet rooms 100% Variable % Yes 275 KITCHE + 6 additional wet rooms 100% Variable % Yes Controller Model Reference number Xcell 350V EC BP 3SS 3 Speed Controller 92396AA 31
32 Xcell 400QV / QVW / QVI Mechanical Ventilation with Heat Recovery and Summer Bypass Key Features The Range QVI/QVI includes summer bypass eft and right hand versions available for handed applications RF controllers available High efficiency counterflow heat recovery cell with up to 91% efficiency Powder coated stainless steel G4 Specification The unit is supplied with a 1m length 20mm Ø (O/D) plastic condensate tubing SAP Appendix Q isted 5 year guarantee The new Xpelair Xcell 400QV is one of a new generation of Carbonite energy efficient Mechanical Ventilation units with Heat Recovery (MVHR) designed modern tight buildings. It is ideal for 3-5 bed houses and large apartments. The Xcell 400QV can be wall or loft mounted. The design combines a highly insulated EPP structural foam body with four 150mm Ø spigot connections, up to 91% energy efficient heat exchanger. UltraEC low energy multi-speed single inlet external rotor motors and long life G4 filters. The Xcell 400QV range will deliver a refreshed indoor environment day-in day-out whilst efficiently recovering up to 91% of the outgoing heat energy. The Xcell 400QV Range has been designed with easy user maintenance in mind, the filters can be accessed for inspection without the unit being electrically isolated. The stylish case can be occasionally wiped clean. Fresh air intake from atmosphere and dwelling extract filters (G4 Specification) are housed within the unit to filter the airstreams before they pass through the heat recovery cell. The filters are accessed through the easy turn access panel. Xcell 400QV Dwelling Extract Atmosphere Discharge Atmosphere Intake Dwelling Supply 4-150/160mm Ø Spigots 32
33 Select the right setting for your application Product Selector Xcell 400QV Xcell 400QVW Xcell 400QVI Xcell 400QV Xcell 400QVW Xcell 400QVI Right Hand Right Hand Right Hand eft Hand eft Hand eft Hand Reference number 92475AW 92476AW 92478AW 92479AW 92480AW 92482AW Electrical power rating Speed 1/2/3 33/61/130 33/61/130 33/61/130 33/61/130 33/61/130 33/61/ V AC 50-60Hz Maximum supply / extract performance (FID, m 3 /h) Maximum supply / extract performance (m 3 Speeds Speed control type Remote DC Remote DC Remote DC Remote DC Remote DC Remote DC oise (db(a)@3m) 29/34/44 29/34/44 29/34/44 29/34/44 29/34/44 29/34/44 Maximum static pressure (Pa) Weight (kg) Guarantee (years) Kg carbon saving (per year) 1520* 1520* 1520* 1520* 1520* 1520* *Based on comparison with 3 standard intermittent AC fans on a 557m 2 detached 6 wet room house, gas heated, build 2006 using SAP 2005 software using best practice (3) tightness. Performance Performance Table Dimensions (mm) Static Pressure in Pa Airflow (C.F.M.) Performance Band Static Resistance w.g Pa Max Speed m 3 /h Min Speed Max Speed Airflow m 3 /h Controller Options: Model MS2 Q3SP QC02 QHS QTS QRFT RF QRFT RF QSD 2 Speed Manual Automatic 3 Speed C0 2 Sensor Humidity Sensor Timer 3 Speed Transmitter Receiver Smoke Alarm Controller Controller Controller Controller Reference number 23513AW 96005AA 96003AA 96009AA 96004AA 96006AA 96007AA 96021AA Xcell 400QV Xcell 400QVW Xcell 400QVI Xcell 400QV Xcell 400QVW Xcell 400QVI 33
34 Xcell 150 / 150R Horizontal Hideaway Heat Recovery Unit MVHR Key Features 2 models are available: 125mm diameter spigots or 204 x 60mm rectangular 217mm low profile height 6 speed options with boost operation 125mm Ø spigot connections External rotor motors Suitable for temperatures up to 40 C Condensation drain pipe The Range Designed for apartments and smaller dwellings the Xpelair Xcell 150 is ideal for recess fitting in ceilings or in lofts with limited space. The Xcell 150 has multi-speed fans which can be set according to the size and number of wet rooms in the home. Xcell 150R is fitted with system-side Profile 60 multi spigots for direct connection to Xpelair flat ducting. Xcell 150 Atmosphere Discharge Atmosphere Intake Dwelling Supply Dwelling Extract 4-125mm Ø Spigots 34
35 Select the right setting for your application Product Selector Xcell 150 Xcell 150R Reference number 91981AA 91976AA Motor type AC AC Maximum supply / extract performance (FID, m 3 /h) Maximum supply / extract performance (m Maximum system pressure (Pa) Power usage maximum (W) V AC 50-60Hz Specific fan power (maximum W/l/s) 3.2* 3.2* Efficiency (%) Speeds 6 6 Speed control type Transformer output Transformer output oise (db(a)@3m) Speed 1/6 27/34 27/34 Spigot diameter (mm) 125 Rectangular 204 x 60mm Installation orientation Horizontal Horizontal Body material Galvanised Steel Galvanised Steel Weight (kg) 25kg 25kg Guarantee (years, UK) 3 3 *Specific fan power is subject to system design resistance. Performance Performance Table Airflow (C.F.M.) Pa Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 m 3 /h m 3 /h m 3 /h m 3 /h m 3 /h m 3 /h Static Pressure in Pa Static Resistance w.g Dimensions (mm) OPTIOA DRAI COECTIOS EITHER SIDE SIDE 'A' SIDE 'B' Airflow m 3 /h Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 OPTIOA DRAI COECTIOS EITHER SIDE SIDE 'A' SIDE 'B' TERMIA BOX TOP Ø125 SPIGOTS Controller Options: 480 FIXIG CETRES 160 F/C 3 SIDE 'A' TOP VIEW 2 SIDE 'B' ED VIEW 4 1 OPTIOA DRAI Model COS XIC1 COECTIOS 2 Speed Switch Speed Controller* 416 EITHER SIDE Reference number 90108AW 21858AW FIXIG CETRES Xcell 150 Xcell 150R One COS Switch is included with each product *imit to 80% speed trim back on speed 1 low Alternate airflow installation interchange, 1 with 4 and 2 with 3 35
36 Xcell 200 / 200R / 200BP / 200RBP Horizontal Hideaway Heat Recovery Unit Key Features ow profile heat recovery unit High efficiency counterflow heat recovery cell with up to 90% efficiency Fitted with four 150mm Ø extract spigot connections Top or bottom access Fresh air intake and dwelling extract filters (EU4) The unit is supplied with a 1m length 12mm Ø (O/D) plastic condensate tubing 3 year guarantee Complete with 4 speed tapped motor. 2 speeds can be selected on installation The Range Designed for the smaller dwelling the Xpelair Xcell 200 is ideal for recess fitting in ceilings or in lofts with limited space. The Xcell 200 has fans the speed of which can be set according to the size and number of wet rooms in the home. Xcell 200R is fitted with system-side Profile 60 multi spigots for direct connection to Xpelair flat ducting. Versions with a motorised summer 100% bypass are available. These use cool summer evening air to give free cooling when the outside air temperature is lower than indoors. Xcell 200 Atmosphere Intake By-Pass Actuator (when fitted) Atmosphere Discharge Dwelling Extract Drain Tube (10Ø) 4-150mm Ø Spigots Dwelling Supply 36
37 Select the right setting for your application Product Selector Xcell 200 Xcell 200R Xcell 200BP Xcell 200RBP Reference number 91977AA 91978AA 91979AA 91980AA Maximum supply / extract performance (FID, m 3 /h) Maximum supply / extract performance (m Maximum system pressure (Pa) Room side spigots Circular Rectangular Circular Rectangular House side spigot size (mm) Ø x 60 Ø x 60 External spigot size (mm) Ø x 60 Ø x 60 Summer bypass o o Yes Yes Specific fan power (maximum W/l/s) 3.4* 3.4* 3.4* 3.4* Efficiency (%) o. speeds options Speed control type Tapped motor Tapped motor Tapped motor Tapped motor Maximum sound pressure high/low 38/30 38/30 38/30 38/30 (db(a)@3m) Power (W) high/low 268/ / / / V AC 50-60Hz Installation orientation Horizontal Horizontal Horizontal Horizontal Body material Galvanised Steel Galvanised Steel Galvanised Steel Galvanised Steel Weight (kg) Guarantee (years) *Specific fan power is subject to system design resistance. Performance Dimensions (mm) Volume (C.F.M.) TERMIA BOX SIDE Ø150 SPIGOTS TERMIA BOX SIDE 350 ED A ED B Static Pressure in Pa FRESH AIR I EXHAUST AIR SUPPY AIR EXHAUST AIR I Speed 1 Speed 2 Speed 3 Speed 4 3 Extract Performance m /h Performance Table Pa Speed 1 Speed 2 Speed 3 Speed 4 m 3 /h m 3 /h m 3 /h m 3 /h Controller Options: ED A BOTTOM EXHAUST AIR ED A FRESH AIR I TOP DRAI TUBE Ø10 Ø10 DRAI TUBE BOTTOM VIEW REMOVABE DRAI TRAY ED B 250 SUPPY AIR ED B EXHAUST AIR I 754 BYPASS ACTUATOR (WHERE FITTED) TERMIA BOX FRESH AIR I ED TOP VIEW A EXHAUST AIR DRAI TUBE Ø FIXIG CETRES EXHAUST AIR I ED B 724 SUPPY AIR Model COS COS/BP 2 Speed Switch 2 Speed Switch Summer/Winter Reference number 90108AW Spares Xcell 200 Xcell 200R Xcell 200BP* Xcell 200RBP* One COS Switch is included with Xcell 200/R *Supplied with One COS/BP 2 Speed Switch and Summer/Winter option 37
38 Xcell 600BP HE EC Horizontal ow Profile Heat Recovery Units Key Features Variable duty curves Bottom access Circular spigots Acoustically lined Integral slotted mounting points 2 year warranty Multi-room extract spigot option Unit or remote mounted speed selector ow profile design for ceiling/floor voids High efficiency EC motors Backward curved fans The Range Xpelair Xcell 600 BP HE EC heat recovery unit is designed to offer flexible, user friendly features making selection and installation easier. The unique speed selector provides a simple means of setting exact air volumes for specific system requirements. Thermal efficiencies of up to 94% are achievable depending on system balance and air temperature differences. Re-heat / cooling coils are also available. Xcell 600BP HE EC Atmosphere Intake By-Pass Actuator (when fitted) Extract Air Exhaust Air Drain Tube (10Ø) 200mm Ø Spigots Supply Air 38
39 Select the right setting for your application Product Selector Xcell 600 BP HE EC Reference number 92544AA Spigot size (mm) 200 Summer bypass Standard Efficiency (maximum %) 94 o. speeds infinite Performance (l/s) Max sound pressure high/low 34/28 Weight (kg) 82 (including coil) Guarantee (years) 2 Options Available Internal Mounting External Mounting Electric Heating PHW Heating CW Cooling Side Access Top Access Bottom Access Rectangular Spigots Technical Data Control ominal Breakout Run Total Typical ominal Volts Airflow dba@ Current Motor S.F.P. Heat (l/s) 1.5m (Amps) Watts (W/l/s) Output (kw) Accessories Available Speed Selectors (remote or unit mounted) Attenuators IP65 pre-wired terminal box ouvred wall terminals Quick clamps Dimensions (mm) PIR control Temp. controls Humidity control CO 2 control Constant Volume controls Matching air valves Motorised duct dampers Sound Power Data Control Speed dba@ Hz. Volts 1.5m k 2k 4k 8k Coil Data Heating Based on 80 O C Flow / 50 O C Return O/S Air Recuperator Coil Output Flow H.P.D. Temp. O c.a.t. O c.a.t. O c (kw) (l/s) (kpa) HEAT EXCHAGER SECTIO THRO ITEGRA MOUTIG POIT DETAI COI ø SPIGOTS SIDE EEVATIO Heating Based on 40 O C Flow / 35 O C Return O/S Air Recuperator Coil Output Flow H.P.D. Temp. O c.a.t. O c.a.t. O c (kw) (l/s) (kpa) Cooling Based on 6 O C Flow / 12 O C Return O/S Air Recuperator Coil Output Flow H.P.D. Temp. O c.a.t. O c.a.t. O c (kw) (l/s) (kpa) Controller Options: Model ECO4 HR Control System XCCO XPIRA XRH PS XCD XPS EC3SS COS/BP CO 2 Sensor Temp. Control System CO 2 Sensor PIR Humidity Pressure Motorised 0-10V Speed 3 Speed 2 Speed Switch Sensor Sensor Sensor Control Controller Controller Summer/Winter Damper Reference number 92578AA 73433AA 21871AA 21856AW 92508AA Various 92581AA 92549AA Spares Xcell 600 BP HE EC 39
40 Xcell 600BP HE EC Horizontal ow Profile Heat Recovery Units Performance XCE 600 BP HE EC Performance Curves V 10V 250 7V Pa V 5.5V l/s m 3 /hr XCE 600 BP HE EC Energy Saving Curves Return Air 20 O C - Balanced Airflow 600m 3 /hr Supply & Exhaust kw/hr Outside Air Temperature DEG.C % Efficiency Outside Temperature (DEG.C) XCE 600 BP HE EC Free Cooling Curves kw/hr Delta t Data based on 600m3/hr airflow (Pro-rata for lower airflows). Delta t = temperature difference between outside, (fresh), and inside air. e.g. 24 O C inside v 14 O C outside = 10 Delta t 40
41 Specification Casings Unit casings shall be manufactured from best quality galvanised sheet steel with access from top or bottom. Reinforced slotted safety fixing points shall be incorporated to facilitate drop-rods or mounting bolts within overall unit width. All permanent fixings shall be riveted and all removable items shall be retained via setscrews and nutserts. Fan mounting plate shall incorporate damped panel technology and shall be easily removable via access panel. Insulation Optional insulation shall be CFC and HFC-free, class O open cell expanded foam, for thermal and acoustic purposes, with a maximum thermal conductivity of w/m 2 k, fully in compliance with ondon Borough and CAA airport authority flammability and toxicity requirements. Adhesive is a light and ageing resistant modified acrylic synthetic resin with high temperature tolerance. Fans Fans shall be single-inlet, single width, direct drive centrifugal type with high efficiency, low noise, backward-curved impellers. Motor/impeller assemblies shall be statically and dynamically balanced, in two planes, in accordance with BS 5265, Part 1, 1979 to G2.5. Fans shall be mounted individually onto fan decks to facilitate easy removal. Motors Motors shall be totally enclosed, high-efficiency, EC, external rotor type with power factors of better than 0.9. Max. ambient operating temp. 50 C. Bearings shall be sealed-for-life, maintenance-free, ball bearing type with a minimum life expectancy of 100,000 hours under design operating conditions. Insulation shall be to Class B with enclosure to IP44. Electrical supply shall be 220/240V 1ph. 50Hz. Speed Selectors Speed control shall by means of 0-10V input giving infinite speed control allowing accurate adjustment to suit site conditions. Optional Terminal Boxes Electrical connections can be wired via an external terminal box, with removable cover, in accordance with current wiring regulations. ote: Refer to the installation manual for wiring diagrams. Filters Filters shall be EU2/3 to Eurovent 4/5. Media shall be extended surface area, continuous filament with F1 fire resistance to DI 53438, dust holding capacity of 400 g/m 2, shall be supported by an integral wire frame and shall have disposable/washable options. Withdrawal shall be via removable bottom access panel. Heaters & Coils Electric heaters shall be open coil, low inertia type fitted with auto-resetting thermal overloads for higher efficiency and greater safety. Outputs from 0.5kW to 6.0kW shall be available on single phase supply operating from on/off, stepped or thyristor controls. (Full control panels are available for unit or remote mounting to specification). Heating & cooling coils shall be 10mm dia. copper tube expanded into aluminium fins for maximum heat transfer. Recuperators (heat recovery cell) Recuperators shall be manufactured from 100% re-cyclable plastic and offer temperature efficiencies up to 94% depending on thermal / humidity conditions and balanced airflow. Summer bypass facility shall be fitted as standard. 41
42 Xcell 600 / 600BP Horizontal Hideaway Heat Recovery Unit Key Features Up to 70% heat recovery Crossflow heat recovery cell Integral slotted mounting points 2 year warranty Optional summer bypass available 6 speeds available Bottom access Circular spigots ow profile design for ceiling/floor voids Acoustically lined The Range Designed for larger properties commercial and institutional application the Xpelair Xcell 600 provides high performance and excellent heat recovery efficiency. Both models feature multi-speed fans chosen for their quiet operation and proven reliability. The heat recovery cell is a high efficiency design having a typical energy recovery rate of up to 70%. The unit is fitted with two heavy duty filters, and an anti-bacterial stainless steel outlet on condensate tray. BP models have a built-in motorised manual summer 100% bypass. This uses cool summer evening air to give free cooling when the outside air temperature is lower than indoors. A remotely positioned speed selector is provided with the unit. Xcell 600 Atmosphere Intake By-Pass Actuator (when fitted) Atmosphere Discharge Dwelling Extract Drain Tube (10Ø) 4-200mm Ø Spigots Dwelling Supply 42
43 Select the right setting for your application Product Selector Xcell 600 Xcell 600BP Reference number 92002AA 92003AA Maximum supply / extract performance (FID, m 3 /h) Speed 1/2/3/4/5/6 268/400/470/534/578/ /400/470/534/578/641 Maximum supply / extract performance (m 3 Speed 1/2/3/4/5/6 85/270/335/420/460/525 85/270/335/420/460/525 Room side spigots Circular Circular House side spigot size (mm) Ø200 Ø200 External spigot size (mm) Ø200 Ø200 Summer bypass o Yes Efficiency (%) o. speeds 6 6 Speed control type Transformer output Transformer output Maximum static pressure (Pa) oise (db(a)@3m) high/low 34/28 34/28 Power (W) V AC 50-60Hz high/low 339/90 339/90 Specific fan power (maximum W/l/s) 1.9* 1.9* Roof space fitment Yes Yes Body material Galvanised Steel Galvanised Steel Weight (kg) Guarantee (years) 3 3 *Specific fan power is subject to system design resistance. Performance Dimensions (mm) Static Pressure in Pa TERMIA BOX SIDE FRESH AIR I ED A EXHAUST AIR Ø150 SPIGOTS SUPPY AIR ED B TERMIA BOX SIDE EXHAUST AIR I Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 ED A BOTTOM TOP ED B DRAI TUBE Ø BYPASS ACTUATOR (WHERE FITTED) TERMIA BOX FRESH AIR I ED TOP VIEW A EXHAUST AIR DRAI TUBE Ø FIXIG CETRES EXHAUST AIR I ED B 724 SUPPY AIR Performance Table Pa Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 m 3 /h m 3 /h m 3 /h m 3 /h m 3 /h m 3 /h EXHAUST AIR ED A FRESH AIR I Ø10 DRAI TUBE BOTTOM VIEW REMOVABE DRAI TRAY SUPPY AIR ED B EXHAUST AIR I Controller Options: Model COS COS/BP 2 Speed Switch 2 Speed Switch Summer/Winter Reference number 90108AW Spares Xcell 600 Xcell 600BP* One COS Switch is included with Xcell 600 *Supplied with One COS/BP 2 Speed Switch and Summer/Winter option 43
44 Xcell 1000 BP HE EC Horizontal ow Profile Heat Recovery High Efficiency Units Key Features Variable duty curves Bottom access Circular spigots Acoustically lined Integral slotted mounting points 2 year warranty Multi-room extract spigot option Unit or remote mounted speed selector ow profile design for ceiling/floor voids High efficiency EC motors Backward curved fans The Range Xpelair packaged heat recovery units are designed to offer flexible, user friendly features making selection and installation easier. The unique speed selector provides a simple means of setting exact air volumes for specific system requirements. Thermal efficiencies of up to 94% are achievable depending on system balance and air temperature differences. Re-heat / after cooling coil is also available. Xcell 1000 BP HE EC Atmosphere Intake By-Pass Actuator (when fitted) Extract Air Exhaust Air Drain Tube (10Ø) 315mm Ø Spigots Supply Air 44
45 Select the right setting for your application Product Selector Xcell 1000 HE EC Reference number 92544AA Spigot size (mm) 315 Summer bypass Standard Efficiency (maximum %) 94 o. speeds infinite Performance (l/s) 250 Max sound pressure high/low 34/28 Weight (kg) 118 (including coil) Guarantee (years) 2 Options Available Internal Mounting External Mounting Electric Heating PHW Heating CW Cooling Side Access Top Access Bottom Access Rectangular Spigots Technical Data Control ominal Breakout Run Total Typical ominal Heat Volts Airflow dba@ Current Motor S.F.P. Output 1.5m (Amps) Watts (W/l/s) Output (kw) Accessories Available Speed Selectors (remote or unit mounted) Attenuators IP65 pre-wired terminal box ouvred wall terminals Quick clamps Dimensions (mm) PIR control Temp. controls Humidity control CO 2 control Constant Volume controls Matching air valves Motorised duct dampers Sound Power Data Control Speed dba@ Hz. Volts 1.5m k 2k 4k 8k Coil Data Heating Based on 80 O C Flow / 50 O C Return O/S Air Recuperator Coil Output Flow H.P.D. Temp. O c.a.t. O c.a.t. O c (kw) (l/s) (kpa) HEAT EXCHAGER SECTIO THRO ITEGRA MOUTIG POIT DETAI COI SPIGOTS SIDE EEVATIO Heating Based on 40 O C Flow / 35 O C Return O/S Air Recuperator Coil Output Flow H.P.D. Temp. O c.a.t. O c.a.t. O c (kw) (l/s) (kpa) Cooling Based on 6 O C Flow / 12 O C Return O/S Air Recuperator Coil Output Flow H.P.D. Temp. O c.a.t. O c.a.t. O c (kw) (l/s) (kpa) Controller Options: Model ECO4 HR Control System XCCO XPIRA XRH PS XCD XPS EC3SS COS/BP CO 2 Sensor Temp. Control System CO 2 Sensor PIR Humidity Pressure Motorised 0-10V Speed 3 Speed 2 Speed Switch Sensor Sensor Sensor Control Controller Controller Summer/Winter Damper Reference number 92578AA 73433AA 21871AA 21856AW 92508AA Various 92581AA 92549AA Spares Xcell 1000 BP HE EC 45
46 Xcell 1000 BP HE EC Horizontal ow Profile Heat Recovery High Efficiency Units Performance 500 XCE 1000 BP HE EC Performance Curves Pa V 8.5V 10V V 100 4V l/s m 3 /hr kw/hr. XCE 1000 BP HE EC Energy Saving Curves Outside Air Temperature DEG.C kw/hr XCE 1000 BP HE EC Free Cooling Curves Delta t Data based on 1000m3/hr airflow (Pro-rata for lower airflows). Delta t = temperature difference between outside, (fresh), and inside air. e.g. 24 O C inside v 14 O C outside = 10 Delta t Temperature Efficiency Curve % Efficiency Outside Temperature (deg.c) Return Air 20 O C - Balanced Airflow 1000m 3 /hr Supply & Exhaust 46
47 Specification Casings Unit casings shall be manufactured from best quality galvanised sheet steel with access from top or bottom. Reinforced slotted safety fixing points shall be incorporated to facilitate drop-rods or mounting bolts within overall unit width. All permanent fixings shall be riveted and all removable items shall be retained via setscrews and nutserts. Fan mounting plate shall incorporate damped panel technology and shall be easily removable via access panel. Insulation Optional insulation shall be CFC and HFC-free, class O open cell expanded foam, for thermal and acoustic purposes, with a maximum thermal conductivity of w/m 2 k, fully in compliance with ondon Borough and CAA airport authority flammability and toxicity requirements. Adhesive is a light and ageing resistant modified acrylic synthetic resin with high temperature tolerance. Fans Fans shall be single-inlet, single width, direct drive centrifugal type with high efficiency, low noise, backward-curved impellers. Motor/impeller assemblies shall be statically and dynamically balanced, in two planes, in accordance with BS 5265, Part 1, 1979 to G2.5. Fans shall be mounted individually onto fan decks to facilitate easy removal. Optional Terminal Boxes Electrical connections can be wired via an external terminal box, with removable cover, in accordance with current wiring regulations. ote: Refer to the installation manual for wiring diagrams. Filters Filters shall be EU2/3 to Eurovent 4/5. Media shall be extended surface area, continuous filament with F1 fire resistance to DI 53438, dust holding capacity of 400 g/m 2, shall be supported by an integral wire frame and shall have disposable/washable options. Withdrawal shall be via removable bottom access panel. Heaters & Coils Electric heaters shall be open coil, low inertia type fitted with auto-resetting thermal overloads for higher efficiency and greater safety. Outputs from 0.5kW to 6.0kW shall be available on single phase supply operating from on/off, stepped or thyristor controls. (Full control panels are available for unit or remote mounting to specification). Heating & cooling coils shall be 10mm dia. copper tube expanded into aluminium fins for maximum heat transfer. Motors Motors shall be totally enclosed, high-efficiency, EC, external rotor type with power factors of better than 0.9. Max. ambient operating temp. 50 C. Bearings shall be sealed-for-life, maintenance-free, ball bearing type with a minimum life expectancy of 100,000 hours under design operating conditions. Insulation shall be to Class B with enclosure to IP44. Electrical supply shall be 220/240V 1ph. 50Hz. Recuperators (heat recovery cell) Recuperators shall be manufactured from 100% re-cyclable plastic and offer temperature efficiencies up to 94% depending on thermal / humidity conditions and balanced airflow. Summer bypass facility shall be fitted as standard. Speed Selectors Speed control shall by means of 0-10V input giving infinite speed control allowing accurate adjustment to suit site conditions. 47
48 Xcell 1000 / 1000BP Horizontal ow Profile Heat Recovery Units Key Features 5 duty curves Side access Circular spigots Multi-room extract spigot option Unit or remote mounted speed selector ow profile design for ceiling/floor voids High efficiency external rotor motors Acoustically lined Integral slotted mounting points 2 year warranty Summer bypass (100%) and free cooling when external temps are lower Heavy duty filters Condensation drain The Range Xpelair packaged heat recovery units are designed to offer flexible, user friendly features making selection and installation easier. The unique speed selector provides a simple means of setting exact air volumes for specific system requirements. Thermal efficiencies of up to 70% are achievable depending on system balance and air temperature differences. Re-heat / after cooling coil is also available. Xcell 1000 Atmosphere Intake By-Pass Actuator (when fitted) Extract Air Exhaust Air Drain Tube (10Ø) 200mm Ø Spigots Supply Air 48
49 Select the right setting for your application Product Selector Xcell 1000 Xcell 1000BP Reference number 92563AA 92564AA External spigot size (mm) Summer bypass o Yes Efficiency (%) o. speeds 5 5 Maximum supply / extract performance (m Maximum static pressure (Pa) oise (db(a)@3m) low/high 25/35 25/35 Power (W) V AC 50-60Hz Roof space fitment Yes Yes Weight (kg) Guarantee (years) 2 2 Pa. Performance XCE 1000 Performance Curves Flow rate in l/s Performance Table Speed Max Speed m 3 /h Flow rate in m /h Dimensions (mm) HEAT EXCHAGER SECTIO THRO ITEGRA MOUTIG POIT DETAI COI SPIGOTS 100 ITERA MOUTIG Controller Options: Model MSC5-6 COS/BP 9 Speed Controller 2 Speed Switch Summer/Winter Reference number 64297AA Xcell 1000 Xcell 1000BP* *Supplied with One COS/BP 2 Speed Switch and Summer/Winter option 49
50 Xcell 1500BP / 2000BP Horizontal ow Profile Heat Recovery Units Key Features Side access Circular spigots Multi-room extract spigot option Unit or remote mounted speed selector ow profile design for ceiling/floor voids High efficiency external rotor motors Acoustically lined Integral slotted mounting points 2 year warranty Summer bypass (100%) and free cooling when external temps are lower Heavy duty filters Condensation drain The Range Xpelair packaged heat recovery units are designed to offer flexible, user friendly features making selection and installation easier. The unique speed selector provides a simple means of setting exact air volumes for specific system requirements. Thermal efficiencies of up to 70% are achievable depending on system balance and air temperature differences. Re-heat / after cooling coil is also available. Xcell 1500BP / 2000BP Atmosphere Intake By-Pass Actuator (when fitted) Extract Air Exhaust Air Drain Tube (10Ø) 315/400mm Ø Spigots Supply Air 50
51 Select the right setting for your application Product Selector Xcell 1500BP Xcell 2000BP Reference number 92565AA 92566AA External spigot size (mm) Summer bypass Yes Yes Efficiency (%) o. speeds 5 5 Maximum supply / extract performance (m Maximum static pressure (Pa) Power (W) V AC 50-60Hz maximum Roof space fitment Yes Yes Weight (maximum kg) Guarantee (years) 2 2 Performance XCE 1500 Series Performance Curves XCE 2000 Series Performance Curves Pa. 150 Pa Flow rate in l/s Flow rate in l/s Flow rate in m 3 /h Flow rate in m 3 /h Sound Power Data Xcell 1500BP Series In-Duct Sound Power Data (w) db ref w Volts Speed dba 3m Hz k 2k 4k 8k Xcell 2000BP Series In-Duct Sound Power Data (w) db ref w Volts Speed dba 3m Hz k 2k 4k 8k Electrical Data Xcell 1500BP Volts ominal dba Max. Start Motor 3m Current Current Watts (l/s) Watts (Amps) (Amps) Xcell 2000BP Volts ominal dba Max. Start Motor 1.5m Current Current Watts (l/s) Watts (Amps) (Amps) Dimensions (mm) HEAT EXCHAGER SECTIO THRO ITEGRA MOUTIG POIT DETAI COI / 1115/ SPIGOTS 100 ITERA MOUTIG Controller Options: Model MSC5-10 COS/BP 9 Speed Controller 2 Speed Switch Summer/Winter Reference number 64299AA Xcell 1500BP* Xcell 2000BP* *Supplied with One COS/BP 2 Speed Switch and Summer/Winter option 51
52 Decentralised System Ventilation Single point ventilation solutions This system is designed for the simultaneous ventilation of separate areas in a house or building or as a multi-point extractor system for larger areas. Using a single energy efficient fan, the unit is located in the loft or airing cupboard, with ducts run to quietly remove pollutants at source from areas such as bathrooms, kitchens, utility rooms and WCs. Premier Ultra The Premier Ultra DC2/DC3 and CV20/40T has been specially designed for through the wall and ducted applications, suitable for internal bathrooms, toilets and other small rooms. Designed for continuous and intermittent use. ovolt XHR150 In existing buildings, single room heat recovery ventilators can be quicker and less disruptive to fit than ducted whole house heat recovery systems. EverDri Ultra DC The effects of moisture created by everyday living can quickly lead to the deterioration of the fabric of a building. Cooking, washing, showering and breathing all create water vapour - up to two gallons for a family of four per day. Without a home being able to breathe, this moisture has nowhere to go. AutoFlow Building refurbishment with replacement double glazing can often lead to condensation problems if there is inadequate ventilation. 52
53 fresh air pure and simple 53
54 Premier Ultra DC2 & DC3 Fan Range Decentralised Extract System Key Features Intermittent operation selectable Extra long life UltraDC motors Easy fit motor cassette feature Filterless, easy maintenance Meets Building Regulations for continuous and intermittent use Suitable for wall or ceiling mounting Removable impeller for cleaning and ease of maintenance Humidity control (CF model) 5 year motor guarantee SEV and integrated transformer models IPX5 suitable for wet zones 1&2 The Range The Premier Ultra DC2/3 has been specially designed for through the wall and ducted applications. It is also suitable for internal bathrooms, toilets and other small rooms. Finished in white, the DC2/3 can be flush or surface mounted, with a 100mm circular spigot for rear entry or via the knock out connection for flat vertical ducting system. A simple to remove front cover, removable impeller and easy fit motor cassette feature simplifies maintenance and assists in quick and simple installation. The DC2/3 incorporates a constant trickle feature, which means that when units are installed in every wet area of the property it can be classed as a whole house system, allowing it to comply with current building regulations for either intermittent or continuous extract. The Premier has versatile standard built-in options, which allows the installer to select a combination of features: humidity control, adjustable overrun timer and Quick Visit delay start and pullcord boost override. Wall mounting 54
55 Select the right setting for your application Product Selector Premier Ultra VDX200T DC2 & DX200T DC3 Premier Ultra VCF20T DC2 & CF20T DC3 (with humidistat control) Reference number VDX200T DC AW DX200T DC AW VCF20T 92335AW CF20T DC AW Humidistat % RH. Factory set at 70% RH Selectable installed performances 6l/s 8l/s 15l/s 6l/s 8l/s 15l/s installed with WD100+CFWG100 kit Sound pressure level (db(a)@3m) Electrical power rating (W) V AC 50-60Hz Specific fan power (maximum W/l/s) IP rating IPX5 IPX5 Weight (Kg) Transformer on V model ocated outside of spray area Zone 0,1,2 ocated outside of spray area Zone 0,1,2 Guarantee (years, UK) 5 5 Kg carbon saving (per year) 17* 17* *Based on comparison with 3 standard intermittent AC fans on a 79m 2 semi detached house, gas heated, build 2006 using SAP 2005 software using best practice (3) tightness. Performance Static Resistance Pa Flush wall mounting Ceiling mounting Trickle 1 Trickle 2 Boost Flow rate m 3 /h Ducted applications Ventilation shaft mounting Ventilation Type Switch umber Constant ight activated Delay Over-run Pullcord Over-ride *Humidity Trickle Speed Switch Speed Timer Timer Switch Speed Over-ride Intermittent WC Bathroom Bathroom WC Constant WC Bathroom Bathroom WC l/s - 15 l/s 15 l/s l/s - 15 l/s 15 l/s l/s 15 l/s 15 l/s l/s 15 l/s 15 l/s l/s l/s 15 l/s l/s 15 l/s - 15 l/s 15 l/s l/s 15 l/s 15 l/s 15 l/s l/s l/s 15 l/s *Humidity Over-ride only available on the VCF20T DC2 version. Switch 1: Continuous trickle On/Off. Switch 2: Set trickle Speed. Switch 3: Delay timer On/Off. Switch 4: ot used Both models are suitable for a constant kitchen ventilation rate of 15 l/s. ote: The VCF20 DC2 & CF20T DC3 Pull Cord Switch will always over-ride the humidity speed or the remote switch speed setting. Dimensions (mm) sq Controller Options: Model COS XPIRA 2 Speed Switch PIR Sensor Reference number 90108AW 21871AA VDX200T DC2 & DX200T DC3 VCF20T DC2 & CF20T DC3 55
56 Premier Ultra CF20/40T CV Fan Range Decentralised Extract System Key Features 1 fan for all applications Constant volume irrespective of system resistance up to 100Pa Extra long life Ultra EC motors Filterless, easy maintenance Meets Building Regulations for continuous and intermittent use Suitable for wall or ceiling mounting Humidity control 5 year motor guarantee IPX5 suitable for wet zones 1&2 The Range The Premier CF20/40T CV model features Ultra EC technology offering reduced energy use, a choice of installed performances and a longer life than a conventional AC motor. The fan is designed to comply with the requirements of Part F1 to provide Intermittent Ventilation in Kitchens, Utility rooms, Bathrooms and Sanitary Rooms, Humidity Controlled intermittent Ventilation + manual over-ride in Kitchens and Bathrooms, Intermittent Ventilation in Internal rooms and Decentralised Continuous Ventilation in Kitchens, Utility Rooms, Bathrooms and Sanitary Rooms. Performance is set at installation via a series of internal dip switches. The Constant Volume nature of the fan means that performance remains constant irrespective of the installed condition up to a system pressure of 100Pa. The fan can be surface or flush mounted in walls and ceilings using the universal mounting accessories provided. The fan is provided with a back draught shutter for intermittent applications. It is not to be fitted for the lower velocity continuous decentralised applications. Control options include integral Humidistat, pullcord over-ride, run on timer and 'quick visit' delay start facility. Xpelair offers a 5 year UK only guarantee. Wall mounting 56
57 Select the right setting for your application Product Selector Premier Ultra CF20/40T CV Reference number 92293AW Humidistat Yes Selectable installed performances 6l/s 8l/s 13l/s 15l/s 30l/s 60l/s installed with WD100+CFWG100 kit oise Electrical power rating (W) V AC 50-60Hz Specific fan power (average appendix Q W/l/s) 0.45 IP rating IPX5 Weight (Kg) 2.7 Guarantee (years, UK) 5 Kg carbon saving (per year) 17* *Based on comparison with 3 standard intermittent AC fans on a 79m 2 semi detached house, gas heated, build 2006 using SAP 2005 software using best practice (3) tightness. Switch Functions Switch 1 - switches continuous trickle On/Off. Switch 2 - sets trickle speed to low or high level (6l/s or 8l/s - CF20, 8l/s or 13l/s - CF40). Sets boost speed on CF40 to slow or fast (30l/s or 60l/s). Switch 3 - enables delay on timer. Switch 4 - In Off position configures fan as CF20, in On position configures fan as CF40. *ote: Humidity speed activated by the humidistat will always over-ride pull cord operation. Remote switch operation will always over-ride pull cord operation. Performance Flush wall mounting Ceiling mounting Ducted applications Ventilation shaft mounting SAP Appendix Q Guide Unit configuration ocation S.F.P (W/l/s) Fan speed cetting I ROOM 2.5m ducted & 1 bend Kitchen 0.43 Kitchen Speed 1 6l/s Speed 2 8l/s Speed 3 13l/s Speed 4 15l/s Speed 5 30l/s Speed 6 60l/s I ROOM 2.5m ducted & 1 bend Wet Room 0.56 Wet Room Dimensions (mm) THROUGH WA with duct kit Kitchen 0.34 Kitchen THROUGH WA with duct kit Wet Room 0.50 Wet Room sq Controller Options: Model COS XPIRA 2 Speed Switch PIR Sensor Reference number 90108AW 21871AA CF20/40T CV 57
58 EverDri Ultra DC Positive Pressure Ventilation Key Features Moisture removal on non trickle ventilated dwellings UltraDC technology for low energy use Extra long life motor for lower whole life costs 4 settings to provide installed performances for varying home sizes Senses air temperature and automatically changes speed and air input Automatically switches off at 25 0 c 5 year UK Carbonite guarantee for peace of mind The Range The effects of moisture created by everyday living can quickly lead to the deterioration of the fabric of a building. Cooking, washing, showering and breathing all create water vapour - up to two gallons for a family of four per day. Without a home being able to breathe, this moisture has nowhere to go. Mould growth on cooler surfaces like window frames and in unventilated spaces such as the back of wardrobes not only looks bad, it can be bad for your health too. The EverDri system is based on a continuous supply of fresh, dry air into the home. This creates a slight positive pressure which forces moisture and contaminant laden air out through natural leakage points in the building. The long life low energy UltraDC motor contained in the system is permanently switched on and automatically temperature regulated to ensure continual air quality. The units are designed to meet Public Sector and Refurbishment Sector requirements for positive pressure ventilation. The EverDri is quick and easy to install and can quickly provide benefits to the entire dwelling. UltraDC motor means that very low running costs can be achieved while maintaining outstanding efficiency. The EverDri system is ideal for existing properties, particularly those with brick walls without a cavity or insulation and with low or intermittent heating periods. 58
59 Select the right setting for your application Product Selector EverDri Ultra DC Reference number 90998AA oft spacing installation Yes Ducted Yes Supply performance (m 3 /h) speed speed speed speed speed 1 86 Supply performance (l/s) speed 5 72 speed 4 60 speed 3 48 speed 2 36 speed 1 24 Power (W) V AC 50-60Hz speed 5 17 speed 4 13 speed 3 10 speed 2 7 speed 1 4 UK only Carbonite guarantee (years) 5 Weight (Kg) 6.24 Kg carbon saving 19* * Typical carbon saving of up to 19kg per annum when compared to a standard decentralised AC equivalent system. Equivalent energy and carbon usage when compared to a standard intermittent extracted dwelling. Performance Air circulation XED - oft unit installed in a house Air volume delivery lit/sec Power (Watts) Operation (Setting) o 24 < 19 C o 36 > 19 C o 36 < 19 C o 48 > 19 C o 48 < 19 C o 60 > 19 C o 60 < 19 C o 72 > 19 C 4 Small 7 Small 7 Average 11 Average 11 arge 13 arge 13 Extra arge 17 Extra arge o All speeds automatically turn off at 25 C setting < ow > High Dimensions (mm)
60 ovolt XHR150 Safety Extra ow Voltage (SEV), Single Room Heat Recovery Ventilator Key Features Suitable for decentralised ventilation and replacement of intermittent fans Up to 80% heat recovery efficiency for reducing energy cost 3 year UK Carbonite guarantee for peace of mind ight time boost inhibitor via a daylight sensor The Range In existing buildings, single room heat recovery ventilators can be quicker and less disruptive to fit than ducted whole house heat recovery systems. Xpelair ovolt XHR150 units can be installed quickly using a standard core drill. Suitable for domestic applications in bathrooms, utility rooms, bedrooms and living rooms. Also suitable for commercial applications such as hotels, offices and meeting rooms. Xpelair ovolt XHR150 is the energy efficient alternative to extract ventilation. It is an effective remedy for damp problems associated with household condensation. The two speed unit removes moist air from the room, which then passes through a heat recovery cell, giving up its heat to the incoming air flow. As it is warmed, the Relative Humidity (RH) reduces dramatically, providing a flow of dry air which in turn acts as a sponge to soak up further moisture in the room. Intake is fixed at less than the extract rate to ensure a slightly negative pressure on the room, so that moist air does not migrate to the rest of the dwelling. XHR150 is more energy efficient than normal fans both in terms of heating and fan running costs. It also complies with current Building Regulations. 60
61 Select the right setting for your application Product Selector XHR150PC XHR150HP Reference number 90821AA 90820AA Integral pullcord Yes Yes Automatic control from remote humidistat o Yes Maximum efficiency (%) Speeds 2 2 Maximum supply / extract performance (m 3 boost trickle Maximum supply / extract performance (l/s) boost 9 9 trickle 3 3 dba boost trickle Power (W) V AC 50-60Hz boost trickle 9 9 Specific fan power (W/l/s) boost trickle 3 3 Hole diameter (mm) Wall thickness range (mm) UK only Carbonite guarantee (years) 3 3 Weight (Kg) Transformer (IP24) on both models ocated outside of spray area ocated outside of spray area Zone 0,1,2 Zone 0,1,2 Kg carbon saving 55* 55* *Typical carbon saving when compared to non-heat recovery standard AC extract fans. ote: imited to low exposure building use, i.e. no high rise above two storey. Dimensions (mm)
62 AutoFlow Passive Air-Input Units Key Features Suitable for decentralised ventilation design atural air-input ventilator for intelligently controlled air input Air temperature sensitive opening and closing mechanism for minimising heat loss 2 year UK only Carbonite guarantee for peace of mind The Range Building refurbishment with replacement double glazing can often lead to condensation problems if there is inadequate ventilation. With central systems, be it central extract using multipoint system or a positive pressure system, it is often now necessary to provide passive ventilators in airtight rooms. Xpelair AutoFlow is a simple and neat passive ventilation unit designed for installation at high level through a wall using a core cutter. Xpelair AutoFlow is self regulating, adjusting the airflow in relation to the outside temperature. A self contained, temperature sensitive thermostatic piston controls the opening of the indoor vent disc. In automatic operation the aperture decreases with declining outdoor temperature and increases with rising outdoor temperature. The unit comes complete with wall tube and outside weather protected wall grille. Diagram showing how AutoFlow opens with increasing temperature 62
63 Select the right setting for your application Product Selector AutoFlow 80 AutoFlow 100 AutoFlow 160 Reference number 91295AW 91296AW 91297AW Operating temperature range (ºC) -5/+10-5/+10 5/+10 Maximum vent opening (mm) Maximum ventilation rate (m 3 /h) Pressure drop at max flow rate (Pa) Diameter (mm) Hole diameter (mm) UK only Carbonite guarantee (years) Weight (Kg) Performance AutoFlow 80 AutoFlow 100 Volume (C.F.M.) Pressure drop in Pa Amount of air AutoFlow 160 Volume (C.F.M.) Thermostat bulb operation 20 Pressure drop in Pa Pressure drop in Pa Amount of air Ventilator opening (mm) Degrees centigrade Amount of air Dimensions (mm) Model A B C D AutoFlow AutoFlow AutoFlow
64 Sensors and Switches Domestic Controls for Xplus Xplus Products Ref Xplus Products Ref Xplus Products Ref Change Over Switch COS 90108AW Used to select between high and low speed operation Surface or recess mounting 85mm (w) x 85mm (h) Used with Xplus 2, Xplus 2 EC & Xplus Manual Change Over Switch MOS 90199AW Switch 1: high/low speed Switch 2: On/Off (auto or manual sensor bypass) Surface or recess mounting 85mm (w) x 85mm (h) Used with Xplus 2, Xplus 2 EC & Xplus Speed Switch X3SC 91457AA Suitable for Xplus 250DC, Xplus 400DC & Xplus 2 EC models Time Delay Controller DT20B 21850AW Usually connected to the lighting circuit Fan switches On with the light. Provides continued ventilation run-on period after the light has been switched Off User adjustable up to 20 min Surface or recess mounting White finish Supply voltage V 50Hz Delay timer period 30 secs - 20 mins Amp inductive load 240V AC 100mm (w) x 86mm (h) x 45mm (d)) Used with Xplus 2, Xplus 2 EC, Xplus 2-340, Xplus 250 DC 8CV & Xplus 400 DC 8CV Humidity Sensor XRH 21856AW Stand alone humidistat switches On when RH rises to preset level and Off when it declines Fan operation indicator light Pullcord operated override switch Surface or recess mounting White finish Supply voltage V 50Hz Amp inductive load 240V AC 160mm (w) x 86mm (h) x 45mm (d) Used with Xplus 2, Xplus 2 EC, Xplus 2-340, Xplus 250 DC 8CV & Xplus 400 DC 8CV Passive Infra Red Sensor XPIRA 21871AA Position to switch the fan on when body movement is detected. Ideal for infrequently used public spaces Built-in run-on timer to avoid nuisance tripping For indoor use only 86mm (w) x 86mm (h) Used with Xplus 2, Xplus 2 EC, Xplus 2-340, Xplus 250 DC 8CV & Xplus 400 DC 8CV AC Variable Speed Controller XIC1 For fine tuning airflows For use with Xplus 2, Xplus & Xcell 150/R 21858AW Air Quality Sensor AQS 92097AW Provides fully automatic control Detects contaminants such as cigarette smoke, body odours, toilet odours and cooking smells Activates ventilation system when preset threshold level is exceeded Can control up to six fans and accessories. Integral timer adjustable from 3-30mins ED status indicator Surface or recess mounting Supply voltage V 50Hz. Amp inductive load 240V AC Alarm connection has maximum inductive load of AC 160mm (w) x 86mm (h) x 41mm (d Used with Xplus 2, Xplus 2 EC, Xplus 2-340, Xplus 250 DC 8CV & Xplus 400 DC 8CV 64
65 Sensors and Switches Domestic Controls for Xcell 150 to 400 Xcell Products Ref 150 to 400 Xcell Products Ref 150 to 400 Xcell Products Ref 2 Speed Switch MS AW 2 speed selector (normal or boost) Surface or Recess mounting 100mm (w) x 86mm (h) x 45 (d) IP42 Used with Xcell 150/200/300/400 QV only 1 max. per system Humidity Sensor QHS 96009AW Surface mounted IP25 Used with Xcell QVW 4 max. per system or 3 max. per system with 1 CO 2 sensor Used with Xcell QVI 8 max. per system or 4 max. per system with 1 CO 2 sensor Change Over Switch COS Used to select between high and low speed operation Surface or recess mounting 85mm (w) x 85mm (h) Used with Xcell 150/R & 200/BP 90108AW 3 Speed Switch Q3SP 96005AA 3 speed selector (trickle, normal or boost) Surface mounting Filter inspection indicator Motor failure indicator 74mm (w) x 74mm (h) IP20 Used with Xcell 150/200/300/400 QVW only CO 2 Sensor QCO AA Monitors indoor air quality Surface mounting 80mm (w) x 120mm (h) x 31 (d) IP20 Used with Xcell QVW/QVI 1 max. per system 3 Speed Selector 3SP SW Used with Xcell 150U & 350V 92396AA Time Controller with 3 Speed Switch Q7TS 96004AA Time controller with 3 speed selector (trickle, normal or boost) Surface mounting 150mm (w) x 90mm (h) x 35mm (d) IP20 Used with Xcell 300/400 QVI only Smoke Detector QSD 96021AA Flush Ceiling Mounted IP20 Used with Xcell QVI 4 max. per system RF 3 Speed Switch Transmitter QRFT 96007AA Requires QRFR receiver 96006AA Remote manual speed controller Up to 6 remote controllers can be used Surface mounting 85mm x 85mm Used with Xcell 300/400 QVI only RF Receiver QRFR One per MVHR IP20 Used with Xcell 300/400 QVI only 96006AA 65
66 Sensors and Switches Commercial Controls for Xcell 600 to 2000 Xcell Products Ref 600 to 2000 Xcell Products Ref 600 to 2000 Xcell Products Ref Change Over Switch COS Used to select between high and low speed operation Surface or recess mounting 85mm (w) x 85mm (h) Used with Xcell 600, Xcell 600BP, Xcell 600BP HE EC, Xcell 1000 AC, Xcell 1000 BP, Xcell 1000BP HE EC, Xcell 1500BP & Xcell 2000BP 90108AW Manual Change Over Switch MOS 90199AW Switch 1: high/low speed Switch 2: On/Off (auto or manual sensor bypass) Surface or recess mounting 85mm (w) x 85mm (h) Used with Xcell 600, Xcell 600BP, Xcell 600BP HE EC, Xcell 1000 AC, Xcell 1000 BP, Xcell 1000BP HE EC, Xcell 1500BP & Xcell 2000BP 9 Step Speed Controller MSC AA MSC AA Single phase speed control Thermal protection included Used with Xcell 600, Xcell 600BP, Xcell 1000 AC, Xcell 1000 BP, Xcell 1500BP & Xcell 2000BP 3 Speed Controller EC3SS 92549AA Using an external selector switch 1 of 3 preset speeds can be selected Used with Xcell 600BP HE EC & Xcell 1000BP HE EC Variable EC Speed Controller XPS XPS 0-10V Speed Controller Used with Xcell 600BP HE EC & Xcell 1000BP HE EC 92581AA Humidity Sensor XRH 21856AW Stand alone humidistat switches On when RH rises to preset level and Off when it declines Fan operation indicator light Pullcord operated override switch Surface or recess mounting White finish Supply voltage V 50Hz Amp inductive load 240V AC 160mm (w) x 86mm (h) x 45mm (d) Used with Xcell 600, Xcell 600BP, Xcell 600BP HE EC, Xcell 1000 AC, Xcell 1000 BP, Xcell 1000BP HE EC, Xcell 1500BP & Xcell 2000BP Heat Recovery ECO4 HR Control System Control System 92578AA Fully automatic CO 2 control system with temperature control Fully compatible with BACET or O BMS Used with Xcell 600BP HE EC & Xcell 1000BP HE EC Change Over Switch & Summer Bypass COS/BP Switch 1: high/low speed Switch 2: On/Off (to select bypass function for summer/winter mode) Surface or recess mounting 85mm (w) x 85mm (h) Used with Xcell 600BP, Xcell 600BP HE EC, Xcell 1000 BP, Xcell 1000BP HE EC, Xcell 1500BP & Xcell 2000BP Available as a spare only Passive Infra Red Sensor XPIRA 21871AA Position to switch the fan on when body movement is detected. Ideal for infrequently used public spaces Built-in run-on timer to avoid nuisance tripping For indoor use only 86mm (w) x 86mm (h) Used with Xcell 600, Xcell 600BP, Xcell 600BP HE EC, Xcell 1000 AC, Xcell 1000 BP, Xcell 1000BP HE EC, Xcell 1500BP & Xcell 2000BP 66
67 Sensors and Switches Commercial Controls for Xcell 600 to 2000 Xcell Products Ref CO 2 Sensor XCCO 73433AA Standalone sensor switches at CO 2 level Used with Xcell 600BP HE EC & Xcell 1000BP HE EC Pressure Sensor PS 92508AA For use with constant volume pressure control Used with Xcell 600BP HE EC & Xcell 1000BP HE EC Motorised Control Damper XCD100 XCD125 XCD150 XCD200 Used with Xcell 600, Xcell 600BP, Xcell 600BP HE EC, Xcell 1000 AC, Xcell 1000 BP, Xcell 1000BP HE EC, Xcell 1500BP & Xcell 2000BP 92609AA 92593AA 92594AA 92595AA 67
68 System X Wholehouse Heat Recovery Ducting Kits Models Ref Xpelair SystemX Kit AA ayout assumptions: Xcell unit in the airing cupboard on first floor Exhaust from family bathroom and one en-suite on first floor, kitchen general vent and cloakroom on ground floor Intake to three bedrooms on first floor, and hall or lounge on ground floor 2 external terminations are required but not included. Use either roof cowl or wall termination set Key Features RegulAir no commissioning grilles Sound and heat insulated ducting The Range Comprises: First fix 5x 2.5m Profile 150 straight duct 2x Profile 150 9º bend 2x Pushfit collar 4x SnapClamp collar 1x 150x150x150 Y splitter 3x 150x125x125 Y splitter 2x 125x125x125 Y splitter 1x 10m Xflex TFD125 26x Worm drive clip 13x Profile 60 flat duct 6x Profile 60 plenum box 9x Profile 60 coupling 3x Profile 60 vertical 90º bend 1x Profile 60 T piece 1x Profile 60 adjustable horizontal bend 26x Profile 60 mounting bracket 11x RegulAir ceiling spigot Second fix 2x Kitchen / utility extract grille 4x RegulAir XEI 125 input grille 1x RegulAir XEP x RegulAir XEH x RegulAir XEV 8 valve Xpelair SystemX Kit AA ayout assumptions: Xcell unit in the airing cupboard on first floor Exhaust from family bathroom and two en-suites on first floor, kitchen general vent and cloakroom on ground floor Intake to four bedrooms on first floor, and hall and lounge on ground floor 2 external terminations are required but not included. Use either roof cowl or wall termination set Xpelair Profile 150 ideally compliments the Xpelair Xcell range of Mechanical Ventilation with Heat Recovery (MVHR) units. Roof cowl Profile 150 roof cowl 2 off required to complete installation 91277AA Designed for quick, easy and mess-free installation. The thick but flexible foam system is lightweight, fire retardant and slim in profile. Straight ducts are supplied in 2.5m lengths and a full range of collar fit bends are available. Where the system is connected to a terminal spigot or where periodic inspection is necessary, SnapClamp collars engage tightly or release completely in seconds allowing fast fitting and release as necessary. A range of matching cowled terminations are available. Atmosphere Discharge Dwelling Supply Dwelling Extract Wall termination set 91455AA Required to complete installation: 2x 150mm Wall duct WD 2x Wall grille 2x Profile º bend 2x 2.5m Profile 150 straight duct 2x Pushfit collar Comprises: First fix 8x 2.5m Profile 150 straight duct 2x Profile º bend 2x Pushfit collar 4x SnapClamp collar 3x 150x150x150 Y splitter 5x 150x125x125 Y splitter 3x 125x125x125 Y splitter 1x 10m Xflex TFD125 38x Worm drive clip 17x Profile 60 flat duct 9x Profile 60 plenum box 12x Profile 60 coupling 4x Profile 60 vertical 90º bend 1x Profile 60 T piece 1x Profile 60 adjustable horizontal bend 34x Profile 60 mounting bracket 12x RegulAir ceiling spigot Second fix 1x Kitchen / utility extract grille 1x RegulAir XEP x RegulAir XEI 125 input grille 1x RegulAir XEP x RegulAir XEH x RegulAir XEV 8 valve Atmosphere Intake 68
69 fresh air pure and simple 69
70 Ducting Profile 150 Insulated Foam Circular System Product Insulated Foam Straight duct P150SD 150mm diameter / 2.5m length Ref 91272AA Insulated Foam Bends 90 O P150B90 150mm diameter 91273AA The Range Xpelair Profile 150 ideally compliments the Xpelair Xcell range of Mechanical Ventilation with Heat Recovery (MVHR) units. Designed for quick, easy and mess-free installation. The thick but flexible foam system is lightweight, fire retardant and slim in profile. Straight ducts are supplied in 2.5m lengths and a full range of collar fit bends are available. Where the system is connected to a terminal spigot or where periodic inspection is necessary, SnapClamp collars engage tightly or release completely in seconds allowing fast fitting and release as necessary. A range of matching cowled terminations are available. Performance Resistance at 225m 3 /h Component Resistance (Pa) Roof cowl as outlet 1.9 Roof cowl as intake Wall cowl as intake Duct per metre º bend º bend º bend 0.4 Insulated Foam Bends 45 O / 30 O / 15 O P150B45 150mm diameter 45 O P150B30 150mm diameter 30 O P150B15 150mm diameter 15 O Un-insulated Y Piece Splitter / Reducers See page 71 Snap Clamp Collar P150SCC 150mm diameter / 100mm length Over centre quick release clamp Pushfit Collar P150PFC 150mm diameter / 100mm length Roof Cowl P150RC Complete with flashing for roof pitch O 91274AA 91275AA 91276AA 91280AA 91279AA 91277AA Wall Cowl P150WC Brown PVC 92436AA 70
71 Ducting Circular Rigid Plastic Insulated & Un-insulated Product Ref Product Ref Insulated Circular Plastic Smooth Ducting CPD mm diameter CPD mm diameter 91474AA 91475AA Un-insulated Circular Connector CPC mm diameter CPC mm diameter CPC mm diameter 92535AA 91485AA 91486AA Un-insulated Circular Plastic Smooth Ducting CPD mm diameter CPD mm diameter CPD mm diameter 92538AA 92539AA 92540AA Un-insulated Diffuser Circular Connector CPCD mm diameter CPCD mm diameter 92536AA 23349AA 90 O Insulated Bend CPB mm diameter CPB mm diameter 90 O Un-insulated Bend CPB mm diameter CPB mm diameter CPB mm diameter 45 O Insulated Bend CPE mm diameter CPE mm diameter 45 O Un-insulated Bend CPE mm diameter CPE mm diameter Insulated Circular T-pieces ITC mm diameter ITC mm diameter Un-insulated Circular T-pieces ITC mm diameter ITC mm diameter ITC mm diameter 91478AA 91479AA 92546AA 92547AA 92548AA 91480AA 91481AA 92542AA 92543AA 91476AA 91477AA 92550AA 92551AA 92552AA Un-insulated Circular Plastic Adapters CPA125/ mm diameter reduction CPA150/ mm diameter reduction CPA180/ mm diameter reduction CPA200/ mm diameter reduction Un-insulated Y Piece Splitter / Reducers YPS x 100 x 100 YPS2 100 x 100 x 125 YPS x 125 x 125 YPS4 125 x 125 x 150 YPS x 150 x 150 YPS6 150 x 150 x 200 YPS x 200 x 200 Thermally Insulated Duct Wrap TIS 1.2 x 1m sheet TIS x 25m sheet TIS mm diameter / 2m length TIS mm diameter / 2m length TIS mm diameter / 2m length Fire Stop Sleeve FSS mm diameter FSS mm diameter 91487AA 91488AA 92520AA 91489AA 91281AA 91282AA 91283AA 91284AA 91285AA 91286AA 91287AA 91494AA 92541AA 92554AA 92555AA 92556AA 92522AA 23314AA 71
72 Ducting Flexible Ducting Product Ref Product Ref Xflex Glass Fibre Fabric Flexible Ducting FD100/ AA 100mm diameter / 3m length FD125/ AA 125mm diameter / 3m length FD150/ AA 150mm diameter / 3m length FD200/ AA 200mm diameter / 3m length FD100/ AA 100mm diameter / 6m length FD125/ AA 125mm diameter / 6m length FD150/ AA 150mm diameter / 6m length FD200/ AA 200mm diameter / 6m length FD250/ AA 250mm diameter / 6m length FD315/ AA 315mm diameter / 6m length Glass fibre fabric on a PVC coated close pitch steel wire helix. 54 minute fire integrity from within as measured to BS 476: Part 20 - (1987) Can be interlocked and sealed with duct tape to form an airtight seal Attached to spigots using worm drive clips Worm Drive Clips WDC5 100mm diameter WDC mm diameter Steel clips for connecting flexible ductwork to spigots Supplied in packs of 10 Un-insulated Flexible Square Ducting FPF5 54 x 110mm to suit Profile m long FPF 60 x 204mm to suit Profile m long FPF9 90 x 220mm to suit Profile m long 89682AA 89685AA 92510AA 91484AA 92354AA ote: Flexible ducting should be limited in use and is not approved for 100% use in BRE Appendix Q approved test methods. ew Aluminium Flexible Ducting Xflex AU100/10 100mm diameter / 10m length AU125/10 125mm diameter / 10m length AU150/10 150mm diameter / 10m length AU200/10 200mm diameter / 10m length Tough foil construction on a high strength wire helix Over 40 minute fire rating BS 476: Part 20 (1987) 91435AA 91436AA 91437AA 91438AA Thermal Flexible Ducting Xflex TFD100/ AA 100mm diameter / 10m length TFD125/ AA 125mm diameter / 10m length TFD150/ AA 150mm diameter / 10m length TFD200/ AA 200mm diameter / 10m length Double skinned insulated aluminium duct with high density fibreglass insulation to minimise condensation formulation 25 minute fire integrity from within as measured to BS 476: Part 20 - (1987) Can be interlocked and sealed with duct tape to form an airtight seal 72
73 Profile 25M / Profile 29 Ducting Metal / Plastic Flat Ducting Systems for Premier Single Point Extraction Profile 25M Flat Metal Dims (230x25mm) Ref Profile 29 Flat White P.V.C Dims (234x29mm) Ref FMD Flat ducting 2.4 metre length 89758AA XFV90 Vertical 90º bend 91110AA FMH90 Horizontal 90º bend 89759AA XFV45 Vertical 45º bend 91111AA FMTB Transition / air brick 89760AA XFEP Elbow bend/plenum 91112AA FMP Plenum box 89761AA XFRRA Round to rectangular adaptor 91113AA FMV90 Vertical 90º bend 89762AA FMH45 Horizontal 45º bend 89763AA XFS Universal support clip 91114AA FMC Coupling (boxed in 6 s) 89764AA FDA Flat ducting adaptor kit 90547AA Profile 29 Flat White P.V.C Dims (234x29mm) Ref XFAA ong airbrick adaptor 91102AA XFD Flat channel duct 1m Flat channel duct 1.5m Flat channel duct 2m 91104AA 91105AA 91106AA XFAF Airbrick fascia terracotta White Brown Cotswold stone 91126AA 91127AA 91128AA XFC Flat channel connector 91107AA XFH90 Horizontal 90º bend 91108AA XFAS Airbrick soldier course 91246AA XFH45 Horizontal 45º bend 91109AA 73
74 Profile 54 / 60 / 90 Ducting Plastic Flat Ducting Systems For MEV & MVHR Product Ref Profile 54: 54x110mm Profile 60: 60x204mm Profile 90: 90x220mm Profile 54 FPD AA Flat ducting, 1.5 metre length Profile 60 FPD AA Flat ducting, 1 metre length FPD AA Flat ducting, 1.5 metre length Profile 90 FPD AA Flat ducting, 1 metre length FPD AA Flat ducting, 1.5 metre length Profile 54 FPH AA Horizontal 90º bend Profile 60 FPH AA Horizontal 90º bend Profile 90 FPH AA Horizontal 90º bend Profile 54 FPV AA Vertical 90º bend Profile 60 FPV AA Vertical 90º bend Profile 90 FPV AA Vertical 90º bend Product Profile 54: 54x110mm Profile 60: 60x204mm Profile 90: 90x220mm Profile 54 FPP5100 Plenum bend 100mm Ø spigot Profile 60 FPP100 Plenum bend 100mm Ø spigot FPP125 Plenum bend 125mm Ø spigot FPP150 Plenum bend 150mm Ø spigot Profile 90 FPP9125 Elbow / plenum box 125mm Ø spigot FPP9150 Elbow / plenum box 150mm Ø spigot Profile 54 FPT5 Rectangular T piece Profile 60 FPT Rectangular T piece Profile 90 FPT9 Rectangular T piece Profile 54 PRA5 Round to rectangular adaptor 100mm Ø spigot Profile 60 PRA Round to rectangular adaptor 125mm Ø spigot Ref 92457AA 89752AA 91259AA 91483AA 92321AA 92322AA 92455AA 90091AA 92515AA 92511AA 91482AA Profile 54 FPH545 Horizontal 45º adjustable bend 92456AA Profile 90 PRA9 Vertical 90º bend 150mm Ø Spigot 92320AA Profile 60 FPH45 Horizontal 45º adjustable bend Profile 90 FPH945 Horizontal 90º adjustable bend 89750AA 92319AA Profile 54 FPC5 Flat channel connector Profile 60 FPC Flat channel connector 92452AA 89757AA Profile 90 FPC9 Flat channel connector 92316AA 74
75 Profile 54 / 60 / 90 Ducting Plastic Flat Ducting Systems For MEV & MVHR Product Profile 54: 54x110mm Profile 60: 60x204mm Profile 90: 90x220mm Ref Product Ref Profile 54: 54x110mm Profile 60: 60x204mm Profile 90: 90x220mm Profile 54 FPV O vertical bend Profile 60 FPV45 45 O vertical bend Profile 54 FPB5 Mounting strap (10 per pack) Price per item 92517AA 92537AA 92519AA Profile 60 FPA6 Adapter Profile Also suitable for double air brick connection using FPA A Profile 90 FPA9 Double air brick connection 92313AA 92323AA Profile 60 FPB Mounting strap (10 per pack) Price per item Profile 90 FPB9 Mounting strap (10 per pack) Price per item Profile 54 FPA5 Adapter profile Also suitable for single air brick connection via cut to length FPB ducting Profile 60 FPA6S Double air brick adapter use 2x air brick FPGR/T/W/B 89756AA 92314AA 92513AA 92573AA Profile 60 FPA6 FPA9 Profile 60 double air brick adapter Use wall outlet grille FPG AA Profile 60/90 FPG9 Terracotta double air brick wall outlet grille to insert in to FPA9 Profile 60 FPG Brown single air brick wall outlet grille to insert in to Profile 60 ducting 92313AA 92323AA 92324AA 89751AA Profile 54/60 FPGRW Airbrick grille white FPGRB Airbrick grille brown FPGRT Airbrick grille terracotta XFAF Cotswold stone 92559AA 91127AA 92558AA 91128AA Profile 54 PBF5 Fire damper collar Profile 60 PBF Fire damper collar Profile 90 PBF9 Fire damper collar 92514AA 91975AA 92516AA Profile 54/60 FPG5 Airbrick grille brown with surround to insert in to Profile 60 ducting 92512AA 75
76 Ducting Extract & Input Grilles Product Ref Product Ref Product Ref RegulAir Ceiling Spigot XECS 91452AA For use in en-suites, bathrooms, kitchens and utility rooms A 125mm first fix spigot that fits flush to the ceiling, allowing decoration without masking Self supporting - no fixings required Complete with rubber seal RegulAir Exhaust grilles Factory set to the exhaust volume requirement for a room. o site balancing is necessary and the performance cannot be tampered with after insulation Pushed into the 125mm ceiling adaptor after decorating is complete as part of the second fix. Additional fixings not necessary Complete with rubber seal RegulAir XEE AA Bathroom/utility grille Preset volume regulator. 8l/s trickle ventilation Electric damper opens to 16l/s RegulAir XEI AA For use in bedrooms, halls and living rooms etc White painted steel finish Hinged diffuser 125 with a distribution pattern allowing installation in the corner of the room 125mm diameter to fit into RegulAir ceiling adaptor Also available in 100mm diameter RegulAir XEP AA Bathroom/utility grille Preset volume regulator. 8l/s trickle ventilation Pullcord opens to 16l/s XEH AA Bathroom/utility grille Preset volume regulator. 8l/s trickle ventilation on-electric humidistat opens to 16l/s XEP AA Sanitary accommodation grille Preset volume regulator. 6l/s trickle ventilation Pullcord opens to 12l/s RegulAir XEV 91446AA 6-12 sanitary accommodation Preset volume regulator. 6l/s trickle ventilation PIR opens to 12l/s RegulAir XEI AA RegulAir XEV induct constant airflow valve. Duct mounted regulator maintains a constant return flow volume to bedrooms etc. fits 125mm Profile 150 or Xflex duct. XEV4 4l/s XEV8 8l/s XEV12 12l/s 91447AA 91448AA 91449AA Important One of the return ducts should not be fitted with a constant airflow valve to maintain balance extract/ intake. This is normally one of the returns to the ground floor. Circular Air Valves (Supply Extract) CAV AA 100mm diameter white plastic CAV AA 125mm diameter white plastic CAV AA 150mm diameter white plastic VD100SS 92488AA 100mm diameter stainless steel Valve has adjustable centre disc Multi inlets/outlets Flexible ducting (FD) can be terminated at the valve Circular Air Valve Fire Damper CAV125FD 91495AA 125mm diameter Circular air valve with integral fire damper Fire Damper XFC AA 100mm diameter XFC AA 100mm diameter XFC AA 100mm diameter XFC AA 100mm diameter For ducts, walls and ceilings. Should not be fitted into flexible ducting. Wall or duct in which XFC is fitted should have a rated fire integrity in accordance with Building Regulations Part B Provides full 1 hour fire check Closing temperature 72 O C ow temperature drop Tested at Warrington Fire Research Centre to BS476 Part 20 Condensation Trap XCT AA For use with 100mm dia ducting Prevents condensed water running back down the duct towards the fan in vertical PVCu pipe ducted applications. (ot suitable for use in a flexible duct run) Collected water must be piped to a convenient disposal point Colour: Grey 20mm drain off point Material: PVCu ength: 85mm Iris Manual Damper DIRU mm diameter DIRU mm diameter 92506AA 92507AA 76
77 Ducting Output Terminals Product Ref Product Ref Product Ref Ceiling Kit XCMK 90066AA Allows a sealed ceiling mounting of ducted products Compete with ceiling adaptor tube 105.7m diameter, rubber gasket and foam strip Used with: Premier Vent Cowl VC AA Provides weather protection for a 100mm PVCu rigid ducted outlet Pushfit and should be secured with solvent adhesive. Material: PVCu Colour: Grey Used with: Premier Cowl diameter: 200mm wø201 x h101 x inner Ø110mm Wall Ducts WD AA 100mm diameter WD AA 125mm diameter WD AA 150mm diameter WD AA 200mm diameter For bridging cavities or lining solid exterior walls Bull-ose Vent Grille BVG100SS 100mm diameter, Stainless Steel 92486AA Easy-Fix Termination Kit EFT 90427AA Designed to be installed from inside a building through a cored out to Ø115mm (nominal) hole drilled in brickwork Easily cut to length Simple installation save times and cost Four sealing rings provide a watertight seal in the external wall Used with: Premier ength: 465mm Wall Vent Kit VK AW To bridge a cavity or line a solid wall hole Complete with wall duct (WD), 155mm square external back-draught shutter, foam strip and wall fixings Grille w155 x h155 Wall hole diameter 117mm Airbrick Adaptor XAA 89777AA A fabricated G.S.M 340mm sleeve to bridge a cavity and line a solid wall Connects to 100mm duct Includes an air brick GSM adaptor Colour: Terracotta Used with all 100mm fans w220 x h65 x d340 Ø 100mm Termination Ducting Kit WT AA 100mm diameter WT AA 150mm diameter For use in through wall applications, ducting can be terminated on the spigot Complete with exterior wall grille (CFWG), wall duct (WD), spigot plate (SP), fixing screws and plugs Wall hole diameter 117mm Wall Grille Gravity Shutter XXWG AW White Plastic XXWG AA Grey Plastic GV100SS 92485AA Stainless Steel Protected duct outlet fitted with gravity flaps 100mm diameter connection Dimensions: w155 x h155 x d15mm Wall Grille CFWG AB Grey CFWG AW White CFWG AB Grey CFWG AW White Surface mounted exterior wall outlet grille For use with 100mm/150mm nominal size ducting Fixing screws provided Dimensions: w150 x h150 x d13mm (CFWG100), w217 x h217 x d24mm (CFWG150) Round Telescopic Pipe XFWT 100mm diameter 91247AA Coweled Outlet C0100SS 100mm diameter Stainless Steel with non-return flap 92484AA 77
78 Ducting Output Terminals Product Ref Product Ref Product Ref ouvred Wall Grille GW AA 125mm diameter white GB AA 125mm diameter brown XEK 91454AA White 125mm frame with removable grille/filter. At least one XEK grille must be used in the system to maintain balanced extract / intake Air Replacement Door Grilles DG-W 89529AA White DG-B 89530AA Brown Tight closing bathroom / toilet doors prevent air circulation to the fan. Air replacement grilles permit air to flow into the room with the door shut Slimline design Consists of two grilles and fixings Minimum door thickness 35mm Dimensions: w454 x h90mm overall, w435 x h77mm hole Circular Silencers SI SI AA 100mm duct diameter x 200mm diameter SI AA 125mm duct diameter x 225mm diameter SI AA 150mm duct diameter x 250mm diameter SI AA 200mm duct diameter x 300mm diameter SI AA 250mm duct diameter x 350mm diameter SI AA 315mm duct diameter x 415mm diameter G.S.M construction Use in multiples for attenuation Fire Blocks FB AA w200 x h200mm FB AA w300 x h300mm For use with air replacement grille (ARG) Fitted between two grilles in a fire door or compartment Spec fire rated 60 mins to BS478 Part 8 Air-Replacement Grilles ARG AA w200 x h200mm ARG AA w300 x h300mm For use with all commercial fans Fitted to doors or partition walls to provide adequate air replacement for a fan Can be used in conjunction with Fire Block FB in fire doors and panels to prevent the breach of fire protected areas or compartments Each set comprises of 2 grilles Grille Box GB20/ AA 100 diameter, 200mm box GB20/ AA 125 diameter, 200mm box GB20/ AA 150 diameter, 200mm box GB30/ AA 200 diameter, 300mm box GB30/ AA 250 diameter, 300mm box GB45/ AA 315 diameter, 450mm box GB50/ AA 315 diameter, 500mm box GB60/ AA 400 diameter, 600mm box Used in conjunction with egg-crate ceiling grille and ceiling diffuser grille to connect to ductwork Use Xflex FD or TFD to attach to spigot and secure with worm drive dip Spigot Plates SP AA 100 diameter, 180mm box SP AA 125 diameter, 175mm box SP AA 150 diameter, 200mm box SP AA 200 diameter, 250mm box SP AA 250 diameter, 300mm box SP AA 315 diameter, 365mm box Fixes to the interior surface of wall to connect to Xflex ducting Connect duct using worm drive clips Material: plastic Air Volume Dampers AVD AA 200mm Square AVD AA 300mm Square AVD AA 450mm Square AVD AA 500mm Square Clips directly to an eggcrate grille or ceiling diffuser grille to adjust the volume of air entering the room ever adjustment Depth 44mm Used together with Grille Box and Xflex ducting Material: Aluminium Mill finish External ouvre Grilles EG AA w300 x h300mm EG AA w450 x h450mm EG AA w500 x h500mm EG AA w670 x h670mm Weather resistant recess mounting fixed louvre grille for exterior walls Aluminium construction Fitted birdguard 78
79 Ducting Output Terminals Product Ref Product Ref Product Ref Egg-crate Ceiling Grilles CG20S 89675AA 200mm square satin silver CG30S 89532AA 300mm square satin silver CG45S 89533AA 450mm square satin silver CG50S 89827AA 500mm square satin silver CG60S 90295AA 600mm square satin silver CG20W 89823AW 200mm square white CG30W 89824AW 300mm square white CG45W 89825AW 450mm square white CG50W 89826AW 500mm square white arge free area Aluminium construction Fixing screws provided (not size 600) Use with grille boxes and Xflex ducting Air Operated ouvre Shutter XG mm diameter XG mm diameter XG mm diameter XG x 200mm diameter XG x 250mm diameter XG x 315mm diameter XG x 400mm diameter Plastic construction Fixed to outside of exterior wall Air operated Colour: white 89691AA 89692AA 89693AA 89694AA 89695AA 89696AA 90294AA Spigot Plates FWS AA 150 diameter, 225mm square FWS AA 200 diameter, 225mm square FWS AA 250 diameter, 300mm square FWS AA 350 diameter, 300mm square FWS AA 400 diameter, 400mm square FWS AA 400 diameter, 450mm square Interlock with four way diffusers Sloping spigot and barbs for easy duct attachment Built-in air volume damper in spigot sizes up to 300mm Ceiling Diffuser Grilles DG20S 89816AA 200mm square satin silver DG30S 89818AA 300mm square satin silver DG45S 89820AA 450mm square satin silver DG50S 89822AA 500mm square satin silver DG60S 90292AA 600mm square satin silver DG20W 89815AW 200mm square white DG30W 89817AW 300mm square white DG45W 89819AW 450mm square white DG50W 89821AW 500mm square white DG60W 90603AW 600mm square white Adjustable grille vanes. Fixing screws provided (not size 600) Use with grille boxes and Xflex ducting Aluminium construction Four Way Ceiling Diffusers FW AA 225 x 225mm diameter FW AA 300 x 300mm diameter FW AA 350 x 350mm diameter FW AA 400 x 400mm diameter FW AA 450 x 450mm diameter FW AA 500 x 500mm diameter* *Outer frame dimensions 600x600mm Rigid lightweight polypropylene frame Four drop-in diffuser cassette can be set up for angled or downward diffusion Each cassette can be fitted eight ways providing multi directional air patterns Secret fixings adjust to varying plasterboard and tile thickness without surface screws argest size drops into 600x600mm ceiling grid system Solid Duct Fasteners XMK AA 100mm duct diameter XMK AA 125mm duct diameter XMK AA 150mm duct diameter XMK AA 200mm duct diameter XMK AA 250mm duct diameter XMK AA 315mm duct diameter XMK AA 400mm duct diameter Metal clamping, vibration absorbent foam Roof Termination Set RC125/150 Suitable for 125 Ø or 150 Ø Ducting RC200/250 Suitable for 200 Ø or 250 Ø Ducting 92311AA 92312AA 79
80 Wiring Diagrams Xplus 2 Controlled by a 3 Speed Selector Switch Unit Connection Terminals 1 Phase (230Vac) (50Hz) ~ Brown (Bn) Blue (Bl) (G/Y) Green / Yellow (G/Y) Double Pole Isolating Switch (By Others) Fuse (G/Y) (Bn) (BI) 3 Speed Selector Switch (BI) (G/Y) (Bn) (Bn) (Bn) Select speeds required: Maximum Speed Boost Speed Trickle Speed Minimum Speed ote: Wiring to be in accordance with current IEE regulations BS7671 or appropriate standards in your country. Refer also to the fiting & wiring instructions for the fans and controllers. Xplus 2 Internal Terminals Controlled by a Change Over Switch Unit Connection Terminals 1 Phase (230Vac) (50Hz) ~ Brown (Bn) Blue (Bl) (G/Y) Green / Yellow (G/Y) Double Pole Isolating Switch (By Others) Fuse (Bn) COS (90108AW) (BI) (G/Y) (Bn) (Bn) Select speeds required: Maximum Speed Boost Speed Trickle Speed Minimum Speed ote: Wiring to be in accordance with current IEE regulations BS7671 or appropriate standards in your country. Refer also to the fiting & wiring instructions for the fans and controllers. 80
81 Xplus Controlled by a 3 Speed Selector Switch Unit Connection Terminals 1 Phase (230Vac) (50Hz) ~ Brown (Bn) Blue (Bl) (G/Y) Green / Yellow (G/Y) Double Pole Isolating Switch (By Others) Fuse (G/Y) (Bn) (BI) 3 Speed Selector Switch (BI) (G/Y) (Bn) (Bn) (Bn) Select speeds required: Maximum Speed Trickle Speed Minimum Speed ote: Wiring to be in accordance with current IEE regulations BS7671 or appropriate standards in your country. Refer also to the fiting & wiring instructions for the fans and controllers. Xplus Internal Terminals Controlled by a Change Over Switch Unit Connection Terminals 1 Phase (230Vac) (50Hz) ~ Brown (Bn) Blue (Bl) (G/Y) Green / Yellow (G/Y) Double Pole Isolating Switch (By Others) Fuse (G/Y) (Bn) (BI) COS (90108AW) (BI) (G/Y) (Bn) (Bn) Select speeds required: Maximum Speed Trickle Speed Minimum Speed ote: Wiring to be in accordance with current IEE regulations BS7671 or appropriate standards in your country. Refer also to the fiting & wiring instructions for the fans and controllers. Xplus Internal Terminals 81
82 Wiring Diagrams Xplus 2 - EC Controlled by a 3 Speed Selector Switch 1 Phase (240Vac) (50Hz) E ~ Green / Yellow (G/Y) Blue (Bl) Brown (Bn) Double Pole Isolating Switch (By Others) Fuse (G/Y) (BI) (Bn) Unit Connection Terminals P Trickle Speed Control ote: Wiring to be in accordance with current IEE regulations BS7671 or appropriate standards in your country. Refer also to the fiting & wiring instructions for the fans and controllers. (Bn) (Bn) P S1 S2 Trickle Speed Medium Speed High Speed S 1 Speed Control S 2 Speed Control 3 Speed Selector Switch Controlled by a Change Over Switch 1 Phase (240Vac) (50Hz) E ~ Green / Yellow (G/Y) Blue (Bl) Brown (Bn) Double Pole Isolating Switch (By Others) Fuse (G/Y) (BI) (Bn) Unit Connection Terminals P Trickle Speed Control ote: Wiring to be in accordance with current IEE regulations BS7671 or appropriate standards in your country. Refer also to the fiting & wiring instructions for the fans and controllers. (Bn) (Bn) P S1 S2 Trickle Speed Medium Speed High Speed S 1 Speed Control S 2 Speed Control COS (90108AW) Selector Switch 82
83 Xplus 2 - EC Controlled by Humidistats or PIR Sensors 1 Phase (240Vac) (50Hz) E ~ Green / Yellow (G/Y) Blue (Bl) Brown (Bn) Double Pole Isolating Switch (By Others) Fuse (G/Y) (BI) (Bn) Unit Connection Terminals P Trickle Speed Control ow Speed Medium Speed Or High Speed P S1 S2 Trickle Speed Medium Speed High Speed S 1 Speed Control S 2 Speed Control Sensor ow Speed Sensor ow Speed Sensor Installation Wiring ote: Wiring to be in accordance with current IEE regulations BS7671 or appropriate standards in your country. Refer also to the fiting & wiring instructions for the fans and controllers. Xplus 250 / 400 DC 8CV Wiring Instructions GREY BACK Wired through a COS Switch BACK GREY 83
84 Wiring Diagrams Xcell 150 / 150R / 150V Controlled by a 2 Speed Selector Switch Xcell 150QV() / 200QV() MS2 Controller AW Controlled by a 2 Speed (MS2) Controller Unit Connection Terminals 10v O/P 0V 10v MS2 Sp. Controller AW E 1 Phase ( Vac) (50/60Hz) ~ Green/ Yellow (GY) Blue (Bl) Brown (Bn) Fuse (GY) (Bl) (Bn) O/P 0V Fused Switch Spur (By Others) Xcell Internal Terminals 84
85 Xcell 150QV() / 200QV() Controlled by a 3 Speed controller ote: When using an easy turn access panel contact switches remove these two links. T T CO 2 Temp Power Indicator Intake Fan Exhaust Fan 1 1 Xcell 150 QVW() / Xcell 200 QVW() PCB Green / Yellow (G/Y) Fuse Blue (Bl) Brown (Bn) ~ T PWM T PWM Type CO 2 O-OFF BDE Temp S1 S2 OT 24V OT D1 D2 D3 T Double Pole Isolating Switch (By Others) 1 Phase ( V 50/60Hz) Q3SP 3 Speed Selector Ref.96005AA S1 S2 D1 D2 D3 T Jumper Postion 1.Open 2.Closed 3.Open 4.Closed 5.Open 6.Closed 7.Open 8.Open 9.Open 10.Open Xcell 150QVW() / Xcell 200QVW() Controlled by a 3 Speed Controller & a CO 2 ote: When using an easy turn access panel contact switches remove these two links. T T CO 2 Temp Power Indicator Intake Fan Exhaust Fan 1 Xcell 150QVW() / Xcell 200QVW() PCB 1 Green / Yellow (G/Y) T PWM T PWM Type CO 2 O-OFF BDE Temp S1 S2 OT 24V OT D1 D2 D3 T Fuse Blue (Bl) Brown (Bn) ~ CO 2 Indoor Air Quality Ref.96003AA S1 S2 D1 D2 D3 Q3SP 3 Speed Selector Ref.96005AA T Jumper Postion 1.Open 2.Closed 3.Open 4.Closed 5.Open 6.Closed 7.Open 8.Closed 9.Open 10.Closed Double Pole Isolating Switch (By Others) 1 Phase ( V 50/60Hz) 85
86 Wiring Diagrams Xcell 150QVW() / 200QVW() Controlled by a 3 Speed controller, CO 2 Sensor & 3 Humidity Sensors (Maximum) ote: When using an easy turn access panel contact switches remove these two links. T T CO 2 Temp Power Indicator Intake Fan Exhaust Fan 1 Xcell 150QVW() / Xcell 200QVW() PCB 1 Green / Yellow (G/Y) T PWM T PWM CO 2 O-OFF BDE Temp Type S1 S2 OT 24V OT D1 D2 D3 T Fuse Blue (Bl) Brown (Bn) ~ Indoor Air Quality Ref AA RH 2 GD 1 V+ 3 RH 2 GD 1 V+ QHS Humidistat Sensor(s) Ref.96009AA (up to 3 maximun) 3 RH 2 GD 1 V+ S1 S2 D1 D2 D3 Q3SP 3 Speed Selector Ref.96005AA T Jumper Postion 1.Open 2.Closed 3.Open 4.Closed 5.Open 6.Closed 7.Open 8.Closed 9.Open 10.Closed Double Pole Isolating Switch (By Others) 1 Phase ( V 50/60Hz) 86
87 Xcell 150QVW() / 200QVW() Controlled by a 3 Speed controller & 4 Humidity Sensors (Maximum) ote: When using an easy turn access panel contact switches remove these two links. T T CO 2 Temp Power Indicator Intake Fan Exhaust Fan 1 Xcell 150QVW() / Xcell 200QVW() PCB 1 Green / Yellow (G/Y) T PWM T PWM CO 2 O-OFF BDE Temp Type S1 S2 OT 24V OT D1 D2 D3 T Fuse Blue (Bl) Brown (Bn) ~ 3 RH 2 GD 1 V+ 3 RH 2 GD 1 V+ 3 RH 2 GD 1 V+ 3 RH 2 GD 1 V+ S1 S2 D1 D2 D3 T Jumper Postion 1.Open 2.Closed 3.Open 4.Closed 5.Open 6.Closed 7.Open 8.Closed 9.Open 10.Closed Double Pole Isolating Switch (By Others) 1 Phase ( V 50/60Hz) QHS Humidistat Sensor(s) Ref.96009AA (up to 4 maximun) Q3SP 3 Speed Selector Ref.96005AA 87
88 Wiring Diagrams Xcell 150U EC BP Controlled by a 3 Speed Selector Switch Green / Yellow (G/Y) Double Pole Isolating Switch (By Others) (G/Y) Unit Connection Terminals 1 Phase (230Vac) (50Hz) ~ Blue (Bl) Brown (Bn) Fuse (BI) (Bn) (Bn) 3 OW M (Bn) 2 MED H (Bn) 1 HIGH 3 Speed Selector Switch ote: Wiring to be in accordance with current IEE regulations BS7671 or appropriate standards in your country. Refer also to the fiting & wiring instructions for the fans and controllers. Xcell 200 / 200R / 200BP / 200RPB Controlled by a 2 Speed Selector Switch 88
89 Xcell 200 / 200R / 200BP / 200RPB 2 Speed and Summer / Winter Bypass Selector Switch Xcell 300QV() / Xcell 400QV() Controlled by a 2 Speed (MS2) Controller MS2 Controller AW Unit Connection Terminals 10v O/P 0V 10v O/P E 1 Phase ( Vac) (50/60Hz) ~ Green/ Yellow (GY) Blue (Bl) Brown (Bn) Fuse (GY) (Bl) (Bn) 0V Fused Switch Spur (By Others) Internal Terminals 89
90 Wiring Diagrams Xcell 300QVW() / Xcell 400QVW() Controlled by a 3 Speed controller ote: When using an easy turn access panel contact switches remove these two links. T T CO 2 Temp Power Indicator Intake Fan Exhaust Fan 1 1 Xcell 300 QVW() / Xcell 400 QVW()PCB Green / Yellow (G/Y) Fuse Blue (Bl) Brown (Bn) ~ T PWM T PWM CO 2 O-OFF BDE Temp Type S1 S2 OT 24V OT D1 D2 D3 T Double Pole Isolating Switch (By Others) 1 Phase ( V 50/60Hz) Q3SP 3 Speed Selector Ref.96005AA S1 S2 D1 D2 D3 T Jumper Postion 1.Open 2.Closed 3.Open 4.Closed 5.Open 6.Closed 7.Open 8.Open 9.Open 10.Open 90
91 Xcell 300QVW() / Xcell 400QVW() Controlled by a 3 Speed controller & 4 Humidity Sensors (Maximum) ote: When using an easy turn access panel contact switches remove these two links. T T CO 2 Temp Power Indicator Intake Fan Exhaust Fan 1 Xcell 300QVW() / Xcell 400 QVW()PCB 1 Green / Yellow (G/Y) T PWM T PWM CO 2 O-OFF BDE Temp Type S1 S2 OT 24V OT D1 D2 D3 T Fuse Blue (Bl) Brown (Bn) ~ 3 RH 2 GD 1 V+ 3 RH 2 GD 1 V+ 3 RH 2 GD 1 V+ 3 RH 2 GD 1 V+ S1 S2 D1 D2 D3 T Jumper Postion 1.Open 2.Closed 3.Open 4.Closed 5.Open 6.Closed 7.Open 8.Closed 9.Open 10.Closed Double Pole Isolating Switch (By Others) 1 Phase ( V 50/60Hz) QHS Humidistat Sensor(s) Ref.96009AA (up to 4 maximun) Q3SP 3 Speed Selector Ref.96005AA 91
92 Wiring Diagrams Xcell 300QVW() / Xcell 400QVW() Controlled by a 3 Speed controller, CO 2 Sensor & 3 Humidity Sensors (Maximum) ote: When using an easy turn access panel contact switches remove these two links. T T CO 2 Temp Power Indicator Intake Fan Exhaust Fan 1 Xcell 300QVW() / Xcell 400QVW() PCB 1 Green / Yellow (G/Y) T PWM T PWM CO 2 O-OFF BDE Temp Type S1 S2 OT 24V OT D1 D2 D3 T Fuse Blue (Bl) Brown (Bn) ~ Indoor Air Quality Ref AA RH 2 GD 1 V+ 3 RH 2 GD 1 V+ QHS Humidistat Sensor(s) Ref.96009AA (up to 3 maximun) 3 RH 2 GD 1 V+ S1 S2 D1 D2 D3 Q3SP 3 Speed Selector Ref.96005AA T Jumper Postion 1.Open 2.Closed 3.Open 4.Closed 5.Open 6.Closed 7.Open 8.Closed 9.Open 10.Closed Double Pole Isolating Switch (By Others) 1 Phase ( V 50/60Hz) 92
93 Xcell 300QVI() / Xcell 400QVI() 7 Day Timer Switch (Xcell QVI model only) RAM 726 CO1 CO2 + - RM RM + - Ø-1ØU + - Ø-1ØU Input_4 Input_3 Input_2 Input_1 Input_Ø + - Output_4 Output_3 Output_2 Output_1 Output_Ø Smoke Detector Humidity Sensor CO 2 Sensor 24V DC Inputs Brown Blue White Black Red 24V DC Outputs S230V 50Hz ink wire between Input 0 and input 2 Off 2 Off Auto P Remove link wire between Input 0 and Input 1 when connecting a 7 day Timer Switch only Auto Off Humidity Sensor (Xcell QVI model only) CO1 CO2 + - RM RM + - Ø-1ØU + - Ø-1ØU Input_4 Input_3 Input_2 Input_1 Input_Ø + - Output_4 Output_3 Output_2 Output_1 Output_Ø Smoke Detector Humidity Sensor CO 2 Sensor 24V DC Inputs 24V DC Outputs Remove link wire between input 1 and input 2 when connecting a Humidity Sensor Humidity Sensor 3 RH (0-10V) 2 GD (0-10V) 1 V+ Manual Re-set Switch (not supplied) 93
94 Wiring Diagrams Xcell 300QVI() / Xcell 400QVI() CO 2 Sensor (Xcell QVI model only) CO1 CO2 + - RM RM + - Ø-1ØU + - Ø-1ØU Input_4 Input_3 Input_2 Input_1 Input_Ø + - Output_4 Output_3 Output_2 Output_1 Output_Ø Smoke Detector Humidity Sensor CO 2 Sensor 24V DC Inputs 24V DC Outputs Remove link wire between input 0 and input 1 when connecting a CO 2 Sensor AC AC V DC - T in T out 0-10V/PWM CO V/Term. CO 2 Sensor Manual Re-set Switch (not supplied) Smoke Alarm (Xcell QVI model only) CO1 CO2 + - RM RM + - Ø-1ØU + - Ø-1ØU Input_4 Input_3 Input_2 Input_1 Input_Ø + - Output_4 Output_3 Output_2 Output_1 Output_Ø Smoke Detector Humidity Sensor CO 2 Sensor 24V DC Inputs 24V DC Outputs + 24V - Smoke Alarm Remove link wire between RM and RM Ony remove link wire between input 0 and input 1 if required, see individual wiring diagrams 94
95 Xcell 300QVI() / Xcell 400QVI() RF Receiver (Xcell QVI model only) White White Blue Red 3A 230V~50Hz Xcell 350V EC BP /H & R/H Controlled by a 3 Speed Selector Switch Green / Yellow (G/Y) Double Pole Isolating Switch (By Others) (G/Y) Unit Connection Terminals 1 Phase (230Vac) (50Hz) ~ Blue (Bl) Brown (Bn) Fuse (BI) (Bn) 3 Speed Selector Switch (92396AA) (Bn) (Bn) (Bn) Blue Wire Brown Wire Black Wire Black/White or Grey Wire ote: Wiring to be in accordance with current IEE regulations BS7671 or appropriate standards in your country. Refer also to the fiting & wiring instructions for the fans and controllers. 95
96 Wiring Diagrams Xcell 600 / 600BP 2 Speed Selector Switch 2 Speed and Summer / Winter Bypass Selector Switch Xcell Speed Selector Switch 2 Speed and Summer / Winter Bypass Selector Switch 96
97 Premier Ultra FA TERMIAS FA TERMIAS FUSE T IVE EUTRA FUSE O/OFF SWITCH T IVE EUTRA DOUBE POE ISOATIG SWITCH Diagram 1 DOUBE POE ISOATIG SWITCH Diagram 3 FA TERMIAS O/OFF SWITCH FUSE AMP (IF REQUIRED T IVE EUTRA DOUBE POE ISOATIG SWITCH Diagram 2 EverDri Ultra DC ovolt XHR150 97
98 Wiring Diagrams Premier DX200T DC3 / CF20T DC3 FA TERMIAS FUSE T DOUBE POE ISOATIG SWITCH Diagram 1 FA TERMIAS FUSE T IK DOUBE POE ISOATIG SWITCH Diagram 2 FA TERMIAS DOUBE POE ISOATIG SWITCH Diagram 3 FUSE O/OFF SWITCH T Diagram 1 Use for intermittent ventilation of bathrooms and continuous ventilation of bathrooms, utility room and WC s Diagram 2 Use for continuous ventilation of kitchens Diagram 3 Use for continuous ventilation of WC s 98
99 Premier VDX200T DC2 / VCF20T DC2 TRASFORMER 23462AA TERMIAS DOUBE POE ISOATIG SWITCH Diagram 1 FUSE T 0 24 T FA TERMIAS TRASFORMER 23462AA TERMIAS DOUBE POE ISOATIG SWITCH Diagram 2 FUSE T 0 24 T IK FA TERMIAS TRASFORMER 23462AA TERMIAS DOUBE POE ISOATIG SWITCH Diagram 3 FUSE O/OFF SWITCH T 0 24 T FA TERMIAS Diagram 1 Use for intermittent ventilation of bathrooms and continuous ventilation of bathrooms, utility room and WC s Diagram 2 Use for continuous ventilation of kitchens Diagram 3 Use for continuous ventilation of WC s 99
100 Morley Way Peterborough PE2 9JJ United Kingdom Tel: +44 (0) Fax: +44 (0) Web: X081 01/02/2010
Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard
Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard Duplexvent DV72 EC MVHR is designed to provide constant volume ventilation levels to exceed the latest Building Regulations 2010. The
MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand
9041381- Issue 6 4/11 MODEL: DV72 Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation: Configuration
HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible
HRU ECO 4 System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible Weight As a result of the unique clamping construction in combination with the plastic/synthetic
squrboxbox heat recovery squrboxbox I technical information
heatrecoveryrange heat recovery squrboxbox I technical information squrboxbox Low depth high performance Only 350mm deep & up to 430l/s, providing the most effective low depth solution. Quietest solution
CADB and CADT-D / DI / DC Series
HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised
Mistrale. Fusion Terminal
Mistrale Fusion Terminal PUBLICATION NATURAL VENT. 1 SEPT 2015 Features - Slimline energy efficient ventilation solution - Standard and high capacity terminals provide 128 or 256 L/s capacity - Compliant
Operation and Installation Manual. Max Series
Operation and Installation Manual Max Series Models 95MAX 155MAX 155ECM 155MAXRX 200MAX 200MAXRX MAXTOP 195DCS 300DCS 200ERV 200ERVD New Auto Dehumidistat Function prevents unwanted use of the dehumidistat
How To Make Your House Breathe
RENEWABLES VENTILATION UNITS Nothing lost plenty of healthy fresh air gained Innovative ventilation units that offer healthy indoor air and significantly lower energy bills 04 2015 STIEBEL ELTRON is full
NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!
Flexit SL4 R Air Handling Unit with rotating recovery system Energy-efficient New control system NEW! Patent applied for! - Simple settings - Flexible installation - User friendly F O R H E A LT H Y I
8W! SILENT-100 Series. 26,5 db BATHROOM EXTRACT FANS. Bathroom and toilet extract fans SILENT-100. Low noise! Water protected! Energy efficient!
Bathroom and toilet extract fans SILENT-100 BATHROOM EXTRACT FANS SILENT-100 Series SILVER versions The SILENT-100 CZ and CRZ can be supplied Range of axial extractors with airflow rates of approx. 95
Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts
Lo w p r o f i l e small air handlers and extract fan units Duties to 0.55m 3 /sec Available with the Electroline fitted control panel Ceiling void friendly - unit heights from 190mm to 350mm Airline VES
BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS
CI/SfB (57) Uniclass L753 October 2015 BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS... PRODUCT RANGE AND OVERVIEW..................................................................................
Under sill units. Type FSL-B-ZAS
.1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
Flexit air handling unit K2 R
Flexit air handling unit K2 R with integrated kitchen hood PATENTED The quietest on the market Modern design Energy-efficient Installation in the kitchen A FOR A HEALTHY ENVIRONMENT Requirement-controlled
Horizontal ventilation units
THE ART OF AIR INNOVATION SINCE 1983 FOR HOMES AND BUSINESSES Horizontal ventilation units Healthy indoor air increases your well-being Today people spend much of their life indoors. It is therefore important
condensation mould high humidity
condensation mould high humidity The Cyclone 7 is a major advancement in extract fan technology, designed to deliver high performance in controlling humidity levels in kitchens, bathrooms and utility rooms
FULL DC INVERTER SYSTEMS
FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation
Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery
Part 3 Ancillary technologies Chapter CONTENTS SCOPE Clause Page DESIGN Design standards D1 1 Statutory requirements D2 1 System design D3 1 Building integration D4 2 Noise D5 2 Access and controls D6
Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590. Rapide Inline Ceiling Extractor Fan, Chrome Fascia 41800040580
Any Queries Call : 08000 23 23 23 Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590 Rapide Inline Ceiling Extractor Fan, White Fascia Illuminated 41800040670 Rapide Inline Ceiling Extractor
Dehumidification Frequently Asked Questions
Dehumidification Basics Why do you want to keep indoor Rh between 30-60%? ASHRAE recommends keeping the relative humidity in a home between 30-60% to limit the effects of many unwanted conditions and harmful
HRU ECO 4 Technical Guide
HRU ECO 4 Technical Guide System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible Climate for life. Technical Guide for a Climate for Life The Itho Group was
Installation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
Delivering exceptional performance and Ecovalue. Ecocent
1 Delivering exceptional performance and Ecovalue. Ecocent 2 The Ecocent Hot Water System As the cost of providing heating and hot water continues to increase, homes and businesses are seeking out more
Zehnder Focus 200. Ventilation device
Ventilation device Use The Zehnder Focus (F) 200 comfort ventilation unit was specially developed for use in demanding residential and commercial buildings. It combines maximum comfort, simple operation
Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE
Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall
RRV934. Multi-controller. Synco living
s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard
Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move
Air conditioning unit 2. Product information for the new Truma air conditioning unit October 2006 Edition Comfort on the move Air conditioning systems Manoeuvring systems Energy systems Heating systems
RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features
RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,
8W! consumption. 26,5 db IP45. BATHROOM EXTRACT FANS SILENT-100 DESIGN 3C Series
SILENT-1 Series Range of axial extractors with airflow rates of 85 m 3 /h, for connection to 1 mm diameter circular ducting. Motor mounted on silent-elastic-blocks which absorb the vibrations and allow
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
york air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
IMPROVING INDOOR AIR QUALITY IN NEW HOMES. MECHANICAL EXTRACT VENTILATION (MEV & dmev)
IMPROVIG IDOOR AIR QUAITY I EW HOMES MECHAICA EXTRACT VETIATIO (MEV & dmev) UAIRE S PEDIGREE Proud to Build British uaire is a world leader in the design and manufacture of fans and ventilation systems.
Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC
Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C. QUICK START GUIDE Fill with
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling. fantech
Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling 2 Ductless Ventilation & Fresh Air Solutions We can fill your home with healthy, fresh air Indoor Air Pollution is real, and it
DESIGNED TO PERFORM NEW BUILDING REGULATIONS APPROVED DOCUMENT F: APRIL 2006. Always Innovating ESTABLISHED 1955
DESIGNED TO PERFORM NEW BUILDING REGULATIONS APPROVED DOCUMENT F: APRIL 2006 Always Innovating ESTABLISHED 1955 So versatile Elegant design goes eye to eye with the quality and attention to detail demanded
Heating and cooling. Insulation. Quick facts on insulation:
Heating and cooling Heating and cooling your home can be one of the biggest users of energy. Efficency in this area can bring great savings. Heating and cooling depend on many contributing factors. The
Gas Condensing Boilers
Gas Condensing Boilers www.johnsonandstarley.co.uk QuanTec Ultra Efficient Condensing Gas Boilers Including HR28C with Integral Passive Flue Gas Heat Recovery As market leaders and innovators, Johnson
The space saving solution.
10 KICKSPACE KICKSPACE. Over 70% of people think that they would benefit from additional kitchen space (ICM Research 2012) Kitchen kindly supplied by Second Nature kitchens - www.sncollection.co.uk The
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
Fans That Sense & Extract Volatile Organic Compounds and Humidity
Premium Choice Ventilation Fans Featuring Fans That Sense & Extract Volatile Organic Compounds and Humidity Indoor Air Quality Concerns Today s homes are built to be tighter and more energy efficient than
ASTACEA4 Inspect complex/central air conditioning systems
Overview This Unit covers the competences required to inspect complex/central air conditioning systems as defined by the CIBSE TM 44 Figure 1.1: Summary of system types and their component parts. The air
Comfosystems Systems with heat recovery for a comfortable indoor climate
Comfosystems Systems with heat recovery for a comfortable indoor climate always around you Heating Cooling Fresh Air Clean Air Zehnder everything you need to create a comfortable, healthy and energy-efficient
RPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
Ecojoist. Practical benefits of Ecojoist. www.eleco.com/gang-nail
Ecojoist Practical benefits of Ecojoist. www.eleco.com/gang-nail Gang-Nail Systems, an Eleco plc company, offer integrated solutions f the timber engineering industry which assist in reducing design, production
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
WHOLE-HOUSE VENTILATION SYSTEMS
Technology Fact Sheet WHOLE-HOUSE VENTILATION SYSTEMS Improved control of air quality Buildings for the 21st Century Buildings that are more energy efficient, comfortable, and affordable that s the goal
Energy Efficient Air Distribution Systems
(57.7) X from Polypipe Ventilation Energy Efficient Air Distribution Systems VSPweb On-line Planner Providing Duct Systems for: Mechanical Ventilation with Heat Recovery Mechanical Extract Ventilation
Bring the fresh in. Dedicated Outside Air Systems
Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health
UDSA - UDSBD unit heater
APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the
Flexit SPIRIT K2R. Air handling unit with integrated kitchen hood
Flexit SPIRIT K2R Air handling unit with integrated kitchen hood The quietest on the market Modern design Energy-efficient Installation in the kitchen Flexit SPIRIT - a new generation of air handling units
The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair
The Concept A Europe-wide research and development programme identified the need for a high performance cassette fan convector, powered by low pressure hot water and compatible with universal suspended
CE6500 Energy Recovery Ventilator
ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge
M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace
TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially
HEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.
ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2
A Prototype Alternative Ventilation System for Retrofit, Rehab and Renovation of Rural Alaska Houses
A Prototype Alternative Ventilation System for Retrofit, Rehab and Renovation of Rural Alaska Houses Robert L Crosby Jr, Biorealis Systems, Inc. Abstract: Bristol Bay Housing Authority (BBHA) currently
KONRAD. Hybrid Fancoil Series
KONRAD Hybrid Fancoil Series Konrad is an innovative radiator which cools you down and warms you up. Indeed, it cools in summer and heats in winter; but it makes it with an incomparable quietness. Thanks
Ventilation Solutions Kitchens. fantech
Ventilation Solutions Kitchens 2 Kitchens Today s kitchens have become much more than a place for cooking and food preparation. The kitchen is the heart of the home. It s the center of activity for the
Decree of the Ministry of the Environment on fire safety of ventilation systems
THE NATIONAL BUILDING CODE OF FINLAND MINISTRY OF THE ENVIRONMENT Housing and Building Department Decree of the Ministry of the Environment on fire safety of ventilation systems Adopted in Helsinki, 18
DIMENSIONS SELV MODELS
25 CURZON - 1mm CENTRIFUGL FNS DIMENSIONS B Ø C D E Measured in mm : 216 B : 195 C : 5 D : 52 E : 98 Ø* * : 8/1 * (8mm without adaptor 1mm with adaptor) CURZON - 1mm CENTRIFUGL FNS 14 12 1 8 6 4 2 14 12
Domestic AC Fans 230V Installation and Operating Guide. eco 230V AC Base Models: icon eco15 72683501 icon15 72591501 icon30 72591601 icon60 72591701
Domestic AC Fans 230V Installation and Operating Guide eco 230V AC Base Models: ico eco15 72683501 ico15 72591501 ico30 72591601 ico60 72591701 ico Domestic Fan 230V Installation, Maintenance and Use ico
Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner
Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of
TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES
TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S NATURAL GAS 40-130 MBH INPUT Due to continuous product improvement, specifications are subject to change
Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools
Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL
Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC
Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide
Mechanical and Natural Ventilation
BBSE3006: Air Conditioning and Refrigeration II http://www.hku.hk/bse/bbse3006/ Mechanical and Natural Ventilation Dr. Sam C. M. Hui Department of Mechanical Engineering The University of Hong Kong E-mail:
TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans
IN-LINE MIXED LOW DUT ANS ultra-quiet Series (16 to 1 models) Low profile Mixed-flow fans with sound-absorbent insulation. Extremely quiet. ertified of Approval Noise Abatement Society (TD-35, TD-5, TD-8
Te c h n i c a l G u i d a n c e D o c u m e n t
F Ventilation Building Regulations 2009 Te c h n i c a l G u i d a n c e D o c u m e n t Contents Page Introduction 2 Transitional Arrangements 2 The Guidance 2 Existing Buildings 2 Technical Specifications
Rochdale Building Control Guide. Approved Document F Means of ventilation
Rochdale Building Control Guide Approved Document F Means of ventilation Coming into effect 1 st October 2010 As we build homes that are more airtight it is increasingly becoming important to ensure that
Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY
Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. QUALITY AIR STARTS HERE. AccuExchange Energy Recovery Ventilator Improve your home s indoor environment by exchanging stale
Combi Unit Genius. The energy efficient Building Service Centre
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Combi Unit Genius The energy efficient Building Service Centre systemair Central Building Services
IH 17025 E Sigma Island 90
INSTRUCTIONS FOR USE Kitchen extractor hood Type: IH 17025 E Sigma Island 90 Dear Customer!! You are now a user of the newest generation kitchen extractor hood type IH 17025 E Sigma Island 90. This hood
warm air for the healthiest, most comfortable home environment possible. This occurs with a system efficiency of up to 90%.
Lifebreath delivers a complete indoor climate control package Indoor comfort in a small package The patented Lifebreath Clean Air Furnace combines the fresh air benefits of the Heat Recovery Ventilator
Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes
Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,
Innovent LASER Packaged Fresh Air Conditioning Units
LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent
Dehumidifier D 850E. - Instruction manual version 02
Dehumidifier D 850E - Instruction manual version 02 Content 1. Description of dehumidifier 1.1. General data 1.2. Technical data 2. Operation and usage 2.1. Usage 2.2. Location and installation 2.3. Preparing
HR System Hoods. For a pleasant atmosphere in the kitchen. Climate for life.
HR System Hoods For a pleasant atmosphere in the kitchen Climate for life. HR System Hoods For a pleasant atmosphere in the kitchen The Itho Group was founded in 1919. In the years since, the company has
about your house How to Get the Ventilation That You Need in Your House Figure 1 Infiltration and exfiltration of air in a house
about your house CE 64 How to Get the Ventilation That You Need in Your House Canadian houses are relatively airtight, and have been for years. The old farmhouses where people lived several generations
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
NUAIRE VENTILATION SYSTEMS FLATMASTER AND FLATMASTER 2000 SYSTEMS
NuAire Ltd Western Industrial Estate Caerphilly Mid Glamorgan CF83 1NA Tel: 02920 858 200 Fax: 02920 858 300 e-mail: [email protected] website: www.nuaire.co.uk NUAIRE VENTILATION SYSTEMS APPROVAL INSPECTION
Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H
HR SERIES HEAT RECOVERY VENTILATOR (HRV) Home Owners Guide Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR100V HR160H & HR220H READ AND SAVE THIS GUIDE PP0924 09/2013 ABOUT S&P S&P is the world's
UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)
UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery
The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity
Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings
Electric Flow Boiler
Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler
Gree Solar Hybrid Hi Wall Inverter Air Conditioner
Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar
CRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
Lesson 36 Selection Of Air Conditioning Systems
Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section
CHAPTER 4 VENTILATION
CHAPTER 4 VENTILATION SECTION 401 GENERAL 401.1 Scope. This chapter, in conjunction with the building code, shall govern the ventilation of spaces within a building intended to be occupied. Mechanical
WhisperGreen Select Ventilation Fans
FV-05-11VKS1, FV-05-11VK1, FV-11-15VK1 FV-05-11VKSL1, FV-05-11VKL1, FV-11-15VKL1 WhisperGreen Select Ventilation Fans n Customizable, all-in-one fan and fan/led light combinations n Pick-A-Flow speed selector
AIR DEHUMIDIFYING 2011. Condensation drying for industry and trade
AIR DEHUMIDIFYING 2011 Condensation drying for industry and trade Condensation drying for industry and trade 2011 DH 18 domestic dehumidifiers Development, production and sales: All from a single source
DUCTED AIR CONDITIONING SOLUTIONS
DUCTED AIR CONDITIONING SOLUTIONS H I G H E N E R G Y E F F I C I E N C Y B A C K E D B Y A 5 Y E A R F U L L P A R T S & L A B O U R W A R R A N T Y DUCTED RANGE WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical