Modicon Fiber Optic Repeaters User s Guide. GM FIBR OPT Rev. B
|
|
|
- Shawn Gray
- 9 years ago
- Views:
Transcription
1 Modicon Fiber Optic Repeaters User s Guide GM FIBR OPT Rev. B 1
2 Contents 1.1 Introduction Electrical Cable Connections Fiber Optic Cable Connections Typical Cable System Layouts Point to Point Configuration Bus Configuration Optical Star Coupler Configuration Self Healing Ring Configuration Selecting Fiber Optic Cable Calculating the Optical Path The Optical Power Loss Budget Point-to-Point Example Star Coupler Connection Example Calculating the Minimum Cable Distance Calculating the Number of Chained Repeaters Recommended Materials Connectors Termination Kits Passive Coupler Tools Fiber Optic Cables Mounting Shelf/Panel Models Mounting Rack Mount Models Connecting the Repeater Observing Safety Precautions Rear Panel Connectors Connecting Power Connecting the Network Cable Setting the Remote I/O Shield to Chassis Jumper Applying Power Reading the Network Indicators Troubleshooting Troubleshooting Fiber Repeaters for Modbus Plus Testing Connections Troubleshooting Fiber Repeaters for Remote I/O Broken Cable Detection and Remedies Remote I/O Systems Modbus Plus Networks Specifications Glossary GM FIBR OPT Contents iii
3 Figures Figure 1 Simplified Internal Schematic of Fiber Optic Repeaters Figure 2 Example of Point to Point Connection Figure 3 Example of Repeaters in a Bus Configuration Figure 4 Example of Optical Star Configuration Figure 5 Example of Self Healing Ring Configuration Figure 6 Mounting Dimensions: Shelf/Panel Models Figure 7 Mounting Dimensions: Rack Mount Models Figure 8 Rear Panel Connectors Figure 9 Indicators Layout iv Contents GM FIBR OPT
4 Fiber Optic Repeaters User s Guide Introduction Electrical Cable Connections Fiber Optic Cable Connections Selecting Fiber Optic Cable Calculating the Optical Path Recommended Materials Mounting Methods Installing the Repeater Reading the Network Indicators Troubleshooting Specifications GM FIBR OPT Fiber Optic Repeaters User s Guide 1
5 1.1 Introduction This manual describes how to install and operate Modicon Fiber Optic Repeaters (Part Numbers 490NRP253, 490NRP254, 490NRP954, NWFR85D200, and NWFR89D200). The repeaters have the following characteristics: Model 490NRP253 provides a Fiber Optic Point-to-Point link between two Modbus Plus connections. The Repeater contains one Fiber Optic Transceiver and one electrical interface for Modbus Plus. Models 490NRP254 and NWFR85D200 provide Fiber Optic Bus and electrical Line-Drop links between Modbus Plus nodes or network segments. Each Repeater contains two Fiber Optic Transceivers and one electrical Modbus Plus interface. Models 490NRP954 and NWFR89D200 provide Fiber Optic Bus and electrical Line-Drop links between Remote I/O nodes or network segments. Each Repeater contains two Fiber Optic Transceivers and one electrical Remote I/O interface. Part Number Network Application Mounting Method Power (Nominal) 490NRP253 Modbus Plus Point-to-Point Panel or Shelf 115/230 Vac, 24 Vdc 490NRP254 Modbus Plus Bus and Line Drop Panel or Shelf 115/230 Vac, 24 Vdc NWFR85D200 Modbus Plus Bus and Line Drop 19 in Rack 125/24 Vdc 490NRP954 Remote I/O Bus and Line Drop Panel or Shelf 115/230 Vac, 24 Vdc NWFR89D200 Remote I/O Bus and Line Drop 19 in Rack 125/24 Vdc Except for their operating power and mounting methods, Modbus Plus repeater models 490NRP254 and NWFR85D200 are identical, and Remote I/O models 490NRP954 and NWFR89D200 are identical. POWER SUPPLY POWER OK ELECTRICAL RX ELECTRICAL TX MBUS+/RIO ELECTRICAL INTERFACE EXTERNAL CONNECTIONS ELECTRICAL PORT COMMUNICATION CONTROLLER FIBER CH1 RX FIBER CH1 TX CHANNEL 1 INTERFACE RX TX FIBER CH1 FIBER CH2 RX FIBER CH2 TX CHANNEL 2 INTERFACE RX TX FIBER CH2 Figure 1 Simplified Internal Schematic of Fiber Optic Repeaters 2 Fiber Optic Repeaters User s Guide GM FIBR OPT
6 1.2 Electrical Cable Connections Electrical connection to the Modbus Plus network is through the standard Modbus Plus 9 pin D connector. Connection to the Remote I/O network is through an F style connector and external Modicon Remote I/O 14 db tap. The electrical port of the Repeater has the same network connections, specifications and restrictions as other Modbus Plus or Remote I/O devices, and must be treated accordingly. Refer to the Modbus Plus System Planning and Installation Guide (GM MBPL 001), or the 984 Remote I/O Planning Guide (GM 0984 RIO) for information regarding planning your network configuration and the installation of the network electrical cable. 1.3 Fiber Optic Cable Connections The fiber optic cable is connected to the fiber optic ports by a low loss, industrial ST type connector. All of the repeaters are passive, meaning there is no regeneration of the received signal in the repeater, and no additional delay to the signal produced by the repeater. Prior to installing the Fiber Optic Repeaters, fiber optic cable must be installed. Follow the cable manufacturer s recommendations for routing, installation, and testing of the cable. Take care when terminating the ends of each fiber optic cable in order to minimize loss of the optical signal. Follow the manufacturer s guidelines for installing optical connectors. Test the cable for proper attenuation prior to the connection of the Fiber Optic Repeaters. The cable ends should be accessible at each installation site. Allow sufficient cable length for a service loop and strain reliefs. Label each cable end to facilitate future maintenance. GM FIBR OPT Fiber Optic Repeaters User s Guide 3
7 1.4 Typical Cable System Layouts This section of your manual describes four typical configurations, and is illustrative of the wide range of Fiber Optic Repeater applications Point to Point Configuration Figure 2 shows a Point to Point connection for two segments of a Modbus Plus network using Fiber Optic Repeaters. The distance between the two Repeaters is limited by the maximum allowable power loss from end to end. Power loss includes the fiber optic cable attenuation, connector losses at the Fiber Optic Receiver and Transmitter ports, and the system margin of 3 db. Methods of calculating the power loss are explained later in this guidebook. BM85 BRIDGE MULTIPLEXER IBM PC/AT 490NRP253 REPEATER COMPACT 984 (A ) with MOTION CONTROL MODBUS PLUS TAPS 490NRP253 REPEATER E PROGRAMMABLE CONTROLLER = COPPER CORE CABLE = CABLE Figure 2 Example of Point to Point Connection 4 Fiber Optic Repeaters User s Guide GM FIBR OPT
8 1.4.2 Bus Configuration Figure 3 shows the use of Fiber Optic Repeaters in a Bus configuration. This type of configuration permits chaining multiple Repeaters to extend the fiber optic link, thus increasing the distance between the nodes of the network. Such a configuration permits connection of single nodes or clusters of nodes over the fiber optic medium. The calculation of the number of chained Repeaters, and the total distance of this type of fiber optic network, is explained later in this guidebook. PANELMATE PLUS 1000 COMPACT 984 (A ) with MOTION CONTROL E PROGRAMMABLE CONTROLLER IBM PC/AT E PROGRAMMABLE CONTROLLER MODBUS PLUS TAPS 490NRP253 REPEATER 490NRP254 REPEATER 490NRP254 REPEATER 490NRP253 REPEATER = COPPER CORE CABLE = CABLE Figure 3 Example of Repeaters in a Bus Configuration GM FIBR OPT Fiber Optic Repeaters User s Guide 5
9 1.4.3 Optical Star Coupler Configuration The use of Optical Star Couplers (active or passive) can provide flexibility in the layout of Modbus Plus and Remote I/O networks. Figure 4 shows one example of an Optical Star Coupler configuration. Additional repeaters can be connected in order to extend communication between electrical links. If a passive Star Coupler is used, the use of 100/140 µm cable is recommended because of its higher available optical power E CONTROLLER 490NRP253 REPEATER #5 490NRP253 REPEATER #6 IBM PC/AT IBM PC/AT 490NRP254 REPEATER #1 OPTICAL STAR COUPLER 490NRP254 REPEATER #4 IBM PC/AT IBM PC/AT MODBUS PLUS TAPS 490NRP253 REPEATER #2 490NRP253 REPEATER #3 16 BUTTON MMI OPERATOR PANEL Compact 984 with MOT 201 Compact 984 with MOT 202 = COPPER CORE CABLE = CABLE Figure 4 Example of Optical Star Configuration 6 Fiber Optic Repeaters User s Guide GM FIBR OPT
10 1.4.4 Self Healing Ring Configuration In some cases, because of the plant layout or network topology, it may be desirable to connect the Modicon fiber optic repeaters in a self healing ring configuration. To support this configuration, the Repeaters have special features built into the signal timing that allow them to be connected in a ring. The advantage of this approach is that if there is a break in the ring, communications will continue on both legs of the cable, thus adding a level of reliability to the system. However, it is important to note that there is no sense bit, and detection of a fault is only accomplished through visual inspection of the indicator lights on each Repeater, and by inspecting the physical status of the cable. If fault tolerance with diagnostics is required from the network, the recommended approach is to use dual cable Modbus Plus Communication Adapters such as the AM S , which do have health and status bits associated with each leg of the cable. Figure 5 shows the Self Healing Ring configuration of Modbus Plus or Remote I/O links connected by Fiber Optic Repeaters over the optical medium. This configuration can be achieved by connecting the second transceiver of the first and last Repeater, in order to close the optical loop. This type of connection has all the advantages of the previously described configurations, along with built in redundancy. A broken connection between any two Repeaters in the ring will automatically reconfigure the network to continue the communication. The total length of the fiber optic cable in this case can be up to 10 km (32,000 ft), and is essentially limited by the blanking built into the Repeater to prevent the second pass of the data through the optical loop. IBM PC/AT E CONTROLLER IBM PC/AT 490NRP254 REPEATER 490NRP254 REPEATER 490NRP254 REPEATER 490NRP254 REPEATER 490NRP254 REPEATER 490NRP254 REPEATER PANELMATE PLUS 1000 = COPPER CORE CABLE = CABLE E CONTROLLER Figure 5 Example of Self Healing Ring Configuration GM FIBR OPT Fiber Optic Repeaters User s Guide 7
11 1.5 Selecting Fiber Optic Cable When selecting which type of fiber optic cable to use, several factors must be considered, among them the cable attenuation and the cable bandwidth. Cable attenuation and bandwidth are parameters specified by the cable manufacturers, and depend upon several factors: the wavelength and the spectral width of the optical signal; the cable index (use graded index only), and the bandwidth (depends upon the size of the cable [50/125 µm, 62.5/125 µm, and 100/140 µm]). The maximum attenuation for an 820nm optical signal is: 50/125 µm cable 3.5 db/km 62.5/125 µm cable 3.5 db/km 100/140 µm cable 5.0 db/km The bandwidth is the parameter limited by the dispersion of the optical signal along the length of the cable. Two types of dispersion exist: modal dispersion and material dispersion. The modal dispersion widely depends on the fiber core size, numerical aperture (NA), and the difference in the refraction coefficient between core and cladding material of fiber optic cable. This difference in refraction is called the cable index, and results in a pulse spreading because of the different traveling distances for different rays of light entering the multimode fiber. For example, a difference of 1% in refraction coefficient between core and cladding material for step index fiber produces a pulse spreading (or pulse width distortion) of 50 ns/km. Modal dispersion (and the resultant pulse width distortion) can be reduced by using a smaller core size cable; using a graded index fiber; and using a fiber with a smaller numerical aperture. Material dispersion results in pulse spreading at the end of the fiber because of the difference in velocities for different wavelengths of the light signal, and depends upon the wavelength and the spectral width of the transmit optical signal. Shown below is the total amount of pulse width distortion (or jitter ), contributed by fiber optic cable for different cable sizes for 820 nm with +50 nm of spectral width optical signal: 50/125 µm 3ns/km where X is the jitter 62.5/125 µm 5ns/km = X in nanoseconds 100/140 µm 7.5ns/km per kilometer Note The value of X is used in the formulas on Page 18 when calculating the maximum number of chained repeaters. 8 Fiber Optic Repeaters User s Guide GM FIBR OPT
12 1.6 Calculating the Optical Path The Optical Power Loss Budget The maximum length of any optical path between two fiber optic repeaters must be calculated separately, and depends on the total loss in all components used in the path, including fiber optic cable, optical connectors, star couplers, and splices. The sum of the losses in all components used in the optical path must not exceed the specified Power Loss Budget for the chosen cable type. The specified Power Loss Budget includes the loss of the two ST type connectors which connect at the two repeaters, and also includes the system margin of 3 db. Thus only other components such as additional connectors, star couplers, and splices, along with cable attenuation, should be taken into account in calculating the loss Point-to-Point Example Point to Point connection of 3 km for two repeaters with one splice using 62.5/125 µm optical cable with attenuation of 3.5 db/km. Power Loss Budget in 62.5/125 µm cable = 11 db Distance between Repeaters = 3 km Cable attenuation = 3.5 db/km Splice Loss =.25 db System loss = 3.5 db/km x 3 km +.25 db = db (less than the allowable Loss Budget of 11 db) Star Coupler Connection Example Total end-to-end connection of 1 km for two repeaters through one star coupler using 100/140 µm optical cable with attenuation of 5 db/km. Power Loss Budget in 100/140 µm cable = 16.5 db Kaptron , 4 x 4, 100/140 µm Star Coupler 8dB loss 2 ST type connectors = 1 db each Distance between Repeaters = 1 km Cable attenuation = 5 db/km System loss = 5 db/km x 1 km + 2 x 1 db + 8 db = 15 db (less than the allowable Loss Budget of 16.5 db) GM FIBR OPT Fiber Optic Repeaters User s Guide 9
13 1.6.2 Calculating the Minimum Cable Distance Because the transmit optical power greatly depends of the fiber size, the calculation of the minimum distance is important to avoid overdriving the Repeater s optical receiver. When 50/125 or 62.5/125 µm cable is used, there is no limit on the minimum distance required. The minimum distance for other fiber sizes must be calculated. Receiver Sensitivity = 30 dbm Repeater Dynamic Range = 20 db, meaning the maximum received Signal = 10dBm Minimum Distance = Maximum Optical Power (dbm) Maximum Received Signal (dbm) Cable attenuation db/km For example, if 100/140 µm fiber is used, the maximum optical power is 4 dbm: 4 dbm ( 10) dbm 5 db/km = 1.2 km Conclusion: When higher Optical Power is required when using the Optical Couplers or Splitters, then it is permissible to use the larger size fiber. For short distances and minimum distortions, use of the 62.5/125 size fiber is a better solution Calculating the Number of Chained Repeaters Because the Repeaters are passive and do not regenerate the received optical data, the number of chained repeaters is limited by the system s total pulse width (jitter) distortions. The total allowable pulse width and jitter distortion is limited to 20% of the bit period, or: for Modbus Plus for Remote I/O 200 nsec 130 nsec The Jitter contributed by Modicon s Fiber Optic Repeaters is 10 nsec per box. The Jitter contributed by the Modbus Plus or Remote I/O electrical interface is 40 nsec (receive transmit). The formula to determine the number (N) of chained Repeaters is: For Modbus Plus N = 200 nsec X(L)nsec 40 nsec 10 nsec where L is the total cable length (km), and X is the jitter in ns/km (see Page 16) For Remote I/O N = 130 nsec X(L)nsec 40 nsec 10 nsec where L is the total cable length (km), and X is the jitter in ns/km (see Page 16) 10 Fiber Optic Repeaters User s Guide GM FIBR OPT
14 1.7 Recommended Materials Modicon offers these guidelines for selecting optical materials Connectors Table 1 Suggested Connectors Connector Type Part Number Description St Bayonet 3M 6105 Epoxy, 40 to + 80 C Operational temp St Bayonet 3M 6100 Hot Melt, 40 to + 60 C Push Pull St 3M 6102 Epoxy, 40 to + 80 C ST Bayonet AMP Series Epoxy, 30 to + 70 C ST Cleave and Crimp AMP Series Cleave and Crimp, 40 to + 65 C Mechanical Line Splice 3M 2529 Fiberlok II One size fits all, 40 to Termination Kits Table 2 Suggested Termination Kits Kit Type Part Number Description Bayonet or Push Pull ST 3M 8154 Epoxy, 110 or 220 VAC, only for 3M Connectors Bayonet or Push Pull ST 3M 6150 Hot Melt, 110 or 220 VAC, only 3M Bayonet ST AMP Epoxy, 110 VAC, only AMP Connectors Bayonet ST AMP EPOXY, 220 VAC, only AMP Mechanical Line Splice 3M 2530 Fiber Splice Prep Kit, Complete with Cleaving Tool Passive Coupler The AMP Model is a pig tail option, and must be used with an enclosure (use AMP Model , a 19 Rack Mount Enclosure, 1.7 high) GM FIBR OPT Fiber Optic Repeaters User s Guide 11
15 1.7.4 Tools Table 3 Tools Product Part Number Description/Use 3M (Photodyne) Optical Source Driver 9XT Hand held optical source driver (requires a light source) 3M (Photodyne) Optical Light Source T 850 nm Light Source, ST Connectors, for 9XT 3M (Photodyne) Power Meter 17XTA 2041 Hand held Fiber Optic Power Meter 3M Optical Light Source, 660 nm, visible 7XE 0660 J Use with 9XT to troubleshoot raw fiber, requires FC/ST patch cord 3M FC/ST Patch Cord BANAV FS 0001 Connects FC connector on 7XE to ST 3M Bare Fiber Adapter, ST Compatible 8194 Permits use of above source and meter to test raw fiber (2 required) Fiber Optic Cables Modicon recommends the use of 62.5/125 graded index, multimode glass fiber for all applications, except where the use of a passive coupler requires use of 100/140 fiber for sufficient launch power to get a satisfactory signal budget. Many cable vendors offer multiple choices for a variety of code ratings. From the variety of cables offered by AMP or Belden, select the one that meets the demands of your application. Wherever possible, Modicon recommends that a multiconductor cable be considered, since it is inexpensive; it provides a backup in case a cable gets cut in the process of pulling it; and you will always find uses for the extra path(s), be it for voice, video, other communications, and/or other control applications. Most 62.5/125 cables are rated at 3.5 db loss per km. With a multiconductor cable, all the pairs come with an attenuation specification as measured. 12 Fiber Optic Repeaters User s Guide GM FIBR OPT
16 1.8 Mounting Shelf/Panel Models Fiber Optic Repeater models are available for mounting on a horizontal shelf or vertical panel. Your choice of mounting method should provide access to the Repeater for observing its status indicators. You should also locate the unit for easy access to its rear panel connectors, for ease of installation and future servicing. The bottom surface of shelf/panel models is fitted with pads for placement on a horizontal surface, such as a shelf or platform. For vertical mounting, use the brackets supplied with the unit for bolting to a panel. The brackets have tabs that insert into slots on the Repeater s bottom panel. No additional hardware is required for securing the brackets to the Repeater. You will have to furnish hardware for bolting the Repeater brackets to your panel. Four bolts are required. Typically, standard 1/4 20 (10mm) bolts will be satisfactory. The mounting brackets supplied with the unit for vertical panel mounting can also be used to secure the unit on a horizontal surface. TOP VIEW ALLOW 4.0 IN (100 MM) REAR CLEARANCE FOR ACCESS TO SWITCHES, CABLES, AND FUSE 8.3 IN (211 MM) Fiber Optic Repeater 490NRP IN (133 MM) 1.53 IN (39 MM) 11.5 IN (292 MM) IN (326 MM) IN (358 MM) REAR PANEL VIEW 2.59 IN (66 MM) Figure 6 Mounting Dimensions: Shelf/Panel Models GM FIBR OPT Fiber Optic Repeaters User s Guide 13
17 1.9 Mounting Rack Mount Models Fiber Optic Repeater models are available for installation into a standard 19-inch rack. Your choice of mounting method should provide access to the Repeater for observing its status indicators. You should also locate the unit for easy access to its rear panel connectors, for ease of installation and future servicing. You will have to furnish hardware for bolting the unit into your rack. Four bolts are required. When mounted, the unit can support itself by its front mounting bolts. It is light enough in weight that you do not have to provide rear support within the rack. FRONT PANEL VIEW 3.0 in (76 mm) 3.47 in (88 mm) in (464 mm) 19.0 in (483 mm) TOP VIEW ALLOW 4.0 IN (100 MM) REAR CLEARANCE FOR ACCESS TO SWITCHES, CABLES, AND FUSE in (438 mm) 9.15 in (232 mm) 8.48 in (215 mm) 1.44 in (37 mm) in (269 mm) Figure 7 Mounting Dimensions: Rack Mount Models 14 Fiber Optic Repeaters User s Guide GM FIBR OPT
18 1.10 Connecting the Repeater Observing Safety Precautions Before installing the Repeater, read the warning and cautions below. Follow them at all times during the installation of the Repeater. Warning DO NOT view the ends of fiber optic cable under magnification while a transmit signal is present on the cable SEVERE EYE DAMAGE MAY RESULT. Use white light ONLY! Caution If you are replacing a Repeater on an active Modbus Plus network, the communication between the two links of the network will be temporarily disabled as you replace the unit. Always plan for an orderly shutdown of your control process (if necessary) while you replace a Repeater on an active network. Caution Fiber Optic Repeaters CANNOT be operated with both 115 VAC and 24 VDC power applied at the same time (i.e., as with UPS backup), or with both 125 VDC and 24 VDC applied at the same time. Caution When DC power is used, the POWER switch on the unit is disabled. Power is supplied to the unit when source power is activated. Under DC power, the unit does not provide surge protection. Caution Do not remove the fiber optic connector covers until the fiber cable is about to be connected. Also, if any optical connector will remain unused, do not remove the connector covers from the unused connector. After connecting the fiber cable, retain the dust covers for future use. GM FIBR OPT Fiber Optic Repeaters User s Guide 15
19 Rear Panel Connectors AC/DC MODELS 24 VDC CONNECTOR CHASSIS GROUND SCREW FIBER PORT 1 FIBER PORT 2 + JP1 1 2 Tx Rx Tx Rx POWER SELECTOR PLUG AND FUSE POWER CABLE CONNECTOR POWER SWITCH REMOTE I/O SHIELD TO CHASSIS JUMPER REMOTE I/O CABLE CONNECTOR MODBUS PLUS CABLE CONNECTOR (RIO MODELS ONLY) (RIO MODELS ONLY) (MODBUS PLUS MODELS ONLY) DC/DC MODELS GROUND FIBER PORT 1 FIBER PORT 2 JP1 1 2 Tx Rx Tx Rx VDC + 24 VDC REMOTE I/O SHIELD TO CHASSIS JUMPER REMOTE I/O CABLE CONNECTOR MODBUS PLUS CABLE CONNECTOR (RIO MODELS ONLY) (RIO MODELS ONLY) (MODBUS PLUS MODELS ONLY) Figure 8 Rear Panel Connectors 16 Fiber Optic Repeaters User s Guide GM FIBR OPT
20 Connecting Power Grounding: The Repeater obtains its ground through the chassis ground screw or DC ( ) wire. Connect the Repeater to the site ground. After making and securing this connection, use a continuity tester to verify the Repeater chassis is grounded to the site ground. Connecting AC Power: Before connecting power, remove the power at its source. The AC power cable supplied with the Repeater is keyed for North American VAC power outlets. If necessary, install a different plug on the cable for the power source at your site. Remove the AC power cable from the Repeater. Set the power selector plug to the VAC or VAC position for the power source at your site. To do this, remove the power selector plug by prying under its tab using a small screwdriver. Set the plug to the proper voltage position as shown on the plug body, then reinsert it. Insert the power cable into the rear panel connector. Plug the cable into the AC power source. Connecting DC Power: Before connecting power, remove the power at its source. Connect the source to the DC power terminals, observing the proper polarity Connecting the Network Cable The electrical cable should already be run to the Repeater site, with a connector installed. If the cable and connector are not in place, refer to the Modbus Plus System Planning and Installation Guide (GM MBPL 001), or the 984 Remote I/O Planning Guide (GM 0984 RIO), for information regarding planning your network configuration and the installation of the network electrical cable. The fiber optic cables should already be run to the site, with connectors installed. If they are not in place, install them using the guidelines given earlier in this guide. Each cable should be labeled to identify the transmit/receive link to which it connects. Refer to Figure 8. Connect the Modbus Plus or Remote I/O electrical cable and the fiber optic cables to the Repeater s rear panel connectors. Secure the electrical cable connector by tightening its two screws. GM FIBR OPT Fiber Optic Repeaters User s Guide 17
21 Setting the Remote I/O Shield to Chassis Jumper The RIO cable shield to chassis jumper (on the rear of the unit) is shipped in the neutral position (midway between 1 and 2 pins.) Set the jumper to the position that will be used in your application. When the jumper is in the 2 position, the RIO cable shield is connected directly to chassis ground. When the jumper is in the 1 position, the RIO cable shield is isolated from chassis ground by a capacitor Applying Power Before applying power, verify that all power connections, electrical cable connections, and fiber optic connections are correctly installed for your application. Applying AC Power: If you are using AC line power, apply AC to the Repeater site. The Repeater s main power switch controls the power to the unit. Set the power switch to the 1 position (ON). The unit s POWER OK indicator will illuminate. Applying DC Power: If you are using DC power, switch on your DC to the Repeater. The unit s POWER OK indicator will illuminate. 18 Fiber Optic Repeaters User s Guide GM FIBR OPT
22 1.11 Reading the Network Indicators The layout of the Repeater s indicators is shown in Figure 9. Refer to the illustration applicable to your unit. 490 NRP 253 power OK fiber port modbus plus 490 NRP 254 power OK fiber port 1 fiber port 2 modbus plus FR85D200 modbus plus fiber port 2 fiber port 1 power OK 490 NRP 954 power OK fiber port 1 fiber port 2 remote I/O FR89D200 remote I/O fiber port 2 fiber port 1 power OK Figure 9 Indicators Layout The POWER OK indicator illuminates steadily when the Repeater has normal power from the AC line or DC source and its internal power supply is operating normally. The MODBUS PLUS or REMOTE I/O port indicator lights when a signal is received at the Repeater s electrical port. Each FIBER port indicator lights when a signal is received at the fiber RX port. If a port indicator fails to illuminate, it can indicate a lack of transmitted signal at another network node. Before replacing the Repeater, check the cable connections on the rear panel for a possible incorrect or loose connection. Also check the indicators on other devices on the signal path to see if the signal loss is external to the Repeater. GM FIBR OPT Fiber Optic Repeaters User s Guide 19
23 1.12 Troubleshooting Troubleshooting Fiber Repeaters for Modbus Plus The indicator lights on Modicon s Modbus Plus Fiber Optic Repeaters can be used to debug and troubleshoot an application. In fact, when the function of the indicators is understood, an installer can usually successfully bring on line good equipment, and isolate fault down to the replaceable element of a system having faulty components. This requires only a knowledge of the indicators operation and the use of known good components. This section explains how the indicators work, and how such knowledge can be used by an installer to bring up a system; or in case of fault, how to troubleshoot down to the replaceable component. An example of indicators on a Modbus Plus Repeater is shown below: power OK fiber port modbus plus Power = ON, steady green, when power is applied. Fiber port 1 = ON, steady amber, when the fiber receiver is receiving packets from another fiber optic repeater. Modbus Plus = ON, steady amber, when the repeater is receiving packets from devices on the wireside Modbus Plus network. The Modbus Plus indicator is also activated by receive signals, illustrated conceptually as: RX Optical Signal Fiber Port MB+ TX Modbus Plus Packet 20 Fiber Optic Repeaters User s Guide GM FIBR OPT
24 The following example makes use of this information in bringing up two point to point fiber optic repeaters. Connect the repeaters as shown: TX RX 490NRP253 FIBER OPTIC REPEATER FR1 RX TX 490NRP253 FIBER OPTIC REPEATER FR2 POWER POWER NOTE: Connect Transmitter to Receiver and Receiver to Transmitter. Duplex cables have markings on one of the two jackets to aid in identification. Apply power and observe: 490NRP253 FIBER OPTIC REPEATER FR1 TX RX 490NRP253 FIBER OPTIC REPEATER FR2 RX TX Pwr FP MB+ Pwr FP MB+ Both power lights should illuminate; no other lights should come on. Now connect a single Modbus Plus Node to one of the repeaters: MODBUS PLUS NODE #1 490NRP253 FIBER OPTIC REPEATER FR1 TX RX RX TX 490NRP253 FIBER OPTIC REPEATER FR2 Pwr FP MB+ Pwr FP MB+ The Modbus Plus Node generates packets, regardless of whether an application is present; therefore, the Modbus Plus receiver is getting data, and its indicator is blinking. The transmitter of FR1 passes the packets to the receiver of FR2, and its fiber port indicator will blink. Note The Repeater s blinking pattern does not follow the standard Modbus Plus network indicator flashing pattern of other Modbus Plus devices. GM FIBR OPT Fiber Optic Repeaters User s Guide 21
25 To verify proper operation of the rest of the system, relocate Modbus Plus Node 1 so it is attached to FR2, as shown below. If the system is configured correctly, the indicators should illuminate as follows: Repeater Indicator Fiber Port Modbus Plus FR1 BLINKING OFF FR2 OFF BLINKING 490NRP253 FIBER OPTIC REPEATER FR1 TX RX RX TX 490NRP253 FIBER OPTIC REPEATER FR2 MODBUS PLUS NODE #1 Pwr FP MB+ Pwr FP MB Testing Connections Most failures in any kind of network are in the medium ; that is, the wire, the fiber, and their connections. Therefore, if any of the above configurations fail to give the expected state of the indicators, your first suspicion should be that the cable, fiber, or their terminations are at fault. Test #1 Test #2 Test #3 In the above example, with Node 1 alone attached to FR1, if the Modbus Plus light on FR1 does not blink, check for continuity of the Modbus Plus cable, pin to pin. If this is correct, try attaching Node 1 to FR2. If the Modbus Plus indicator on FR2 begins to blink, then Node 1 must be transmitting, FR2 is receiving, and FR1 has failed and needs replacement. If Node 1 attached to FR2 fails to cause the Modbus Plus indicator to blink, Node 1 must be presumed to have failed. Assuming Node 1 attached to FR1 succeeds in illuminating the Modbus Plus indicator, the FP indicator of FR2 should blink. If it does not, reverse the fiber connections at either one or another (but not both) of the fiber repeaters. [The correct connection is Transmitter to Receiver, Receiver to Transmitter.] If the fiber port indicator of FR2 still fails to blink, reattach Node 1 to FR2. After Node 1 is reattached to FR2, the Modbus Plus indicator of FR2 and the FP indicator on FR1 should both be on. If this test succeeds, you have probably isolated the failure to the optical fiber now connected to the receiver of FR2, the transmitter of FR1. To confirm this suspicion, reverse the fiber connections to both FRs. If, as suspected, one fiber repeater is bad, Node 1 attached to FR2 will no longer communicate to FR1. If Node 1 is reattached to FR1, then the signal will transmit to FR2. Having isolated the fault to the fiber, you will have to use other tools, such as a light source and power meter, to verify discontinuity, and then confirm continuity after correction of the fault. 22 Fiber Optic Repeaters User s Guide GM FIBR OPT
26 Using the tests just described, most of the time you will be able to find the fault/failure in a broken system without use of elaborate test equipment. Necessary components (pre tested for reliability) for such troubleshooting are: a Modbus Plus node (It can but need not be running an application. All it must do is pass tokens to be usable.) a length of Modbus Plus cable, properly terminated Fiber Optic Repeater a fiber pigtail knowledge and implementation of the above procedures. The previous descriptions use the 490 NRP 253 Repeater, which has a single fiber port. You can use a two port Repeater in the same place as a single port unit, but the reverse is not true. When a two port unit is used as a point to point device, one fiber port is simply not connected. GM FIBR OPT Fiber Optic Repeaters User s Guide 23
27 Troubleshooting Fiber Repeaters for Remote I/O Examine this conceptual diagram of a typical Remote I/O Fiber Optic application: MASTER NODE PLC S db Tap Coaxial Cable To Other Drops or Repeaters Coax May or May Not be Connected to Other Drops or Repeaters TX Fiber RX 490 NRP NRP 954 FP2 FR1 FP1 FP1 FR2 FP2 RX Fiber TX May or May Not be Connected to Other Drops or Repeaters To Other Drops or Repeaters 14 db Tap DROP J There are well documented procedures for analyzing the wireside characteristics of this type application, and it is recommended they be used as a first line of attack and afterward whenever trouble is suspected. If the S908 is working properly, it should cause the Remote I/O indicator for FR1 to blink. If that indicator blinks as expected, then the fiber port indicator (FP1) for FR2 should blink, and the other (FP2) should be OFF. If the FP1 indicator does not blink, check for proper connection (Transmit to Receive, Receive to Transmit). If no results are obtained, substitute a known good FR for the one at FR2 and proceed from the beginning. If this fails, the fault has been isolated to faulty fiber, and fiber testing procedures must be used. 24 Fiber Optic Repeaters User s Guide GM FIBR OPT
28 Broken Cable Detection and Remedies Remote I/O Systems Unlike S908 coaxial cable, fiber optic cable contains physically separate transmit and receive lines. It is possible to lose communications through the receive line while the transmit line remains intact, as depicted here: PLC S908 RI/O COAXIAL CABLE TO DROP NRP 954 S908 BRIDGE TX RX RX TX CABLE BROKEN OR DISCONNECTED RECEIVE LINE 490 NRP 954 S908 BRIDGE S908 RI/O COAXIAL CABLE TO DROP 2 S908 RI/O HEAD B IN B OUT A break in the receive line as shown above will deprive the PLC of input data. Under ordinary circumstances, the PLC will continue to drive outputs via the intact transmit line. This could lead to outputs turning ON or OFF due to invalid (INPUT STATE: 0) input data. A method to prevent this from happening is to use STAT and SENS function blocks in the PLC s ladder logic to detect the loss of input communication. This logic can inhibit outputs from improper state changes. Here is an example: GM FIBR OPT Fiber Optic Repeaters User s Guide 25
29 Seg. 1 #1 / STAT #0187 # SENS ( ) # ( ) ( ) The STAT and SENS blocks monitor the I/O status of Drop #2 and inhibit outputs and if communications are lost. The STAT block provides access to the system s status, including the status of S908 communications. The status information is stored in a table which starts at and has a length of 187 words (as shown in the top and bottom nodes of the STAT block). The SENS block has been programmed to sense the first, or Communications Health, bit (SENS top node value = 1) of the 185th word in the status table (SENS middle node value = 40285). This bit is the communications health for Drop 2 of the S908. Coils and in the example have been configured as outputs in the I/O Map, as shown below. 26 Fiber Optic Repeaters User s Guide GM FIBR OPT
30 Utility DelDrop HoldTme ASCPort GetDrop Quit F1 F2 F3 F4 F5 F6 F7 Lev8 F8 OFF F9È I/O MAP 800 SERIES I/O Drop : 2 of 32 Rack : 1 Drop Hold Up Time: 3 (x100ms) ASCII Port : 0 Number Inputs: 16 Number Outputs : 16 Module Reference Numbers Data Module Slot Type Input Output Type Description PLC 685E PLC 685E 103 B IN B B OUT B B8 106 B8 107 B8 108 B8 109 B8 110 B8 111 B8 When the PLC s Rx line is broken as depicted, the SENS ed bit becomes 0 (OFF). The middle node output to coil is set to 0 (OFF). Coil controls normally open relays which, when power is removed, opens the circuits to coil and coil 00002, thus inhibiting these outputs. As an alternative, the logic could control a SKP block to prevent execution of that portion of the network which would ordinarily output data through coils and Refer to the Modicon 984 Programmable Controller Systems Manual (GM 0984 SYS) for further information about using STAT and SENS and SKP blocks for this application. Be sure to test your logic for correct performance. GM FIBR OPT Fiber Optic Repeaters User s Guide 27
31 Modbus Plus Networks Due to the nature of fiber optic cable, it is possible to break or disconnect the TX line independent of the RX line. The effect of this on a Modbus Plus network is shown in the following example: PC 3 (Running MBPSTAT) SEE NETWORK STATUS DISPLAY A PLC 1 PLC 2 MODBUS PLUS CABLE 490 NRP 253 MODBUS PLUS PT to PT CABLE WITH BROKEN OR DISCONNECTED TRANSMIT LINE TX RX RX TX 490 NRP 253 MODBUS PLUS PT to PT MODBUS PLUS CABLE PLC 4 PLC 5 PC 6 (Running MBPSTAT) SEE NETWORK STATUS DISPLAY B Note that the sample network consists of six nodes, three on either side of each Fiber Optic Repeater. A broken Tx line from the standpoint of nodes 1, 2, and 3 will cause the Modbus Plus network indicator LED s on every node to illuminate. This disconnect code consists of 2 flashes, followed by a 2 second pause. The two PLC s and the PC will cease data communications. The MBPSTAT program, running on the PC at node 3, displays all six nodes of the network, but no communication activity. 28 Fiber Optic Repeaters User s Guide GM FIBR OPT
32 MODBUS PLUS NETWORK STATUS version 2.30 Global Data Activity, strike any key to exit Adapter: 0 Success: 0 Failure: DISPLAY A On the other side of the break, nodes 4, 5, and 6 re form into a smaller Modbus Plus network. The Modbus Plus status LED s at each node blink rapidly, indicating normal communication among these three nodes. Note that MBPSTAT, running on the PC at Node 6, displays only the three nodes of the re formed network. MODBUS PLUS NETWORK STATUS version 2.30 Global Data Activity, strike any key to exit Adapter: 0 Success: 103 Failure: DISPLAY B GM FIBR OPT Fiber Optic Repeaters User s Guide 29
33 1.13 Specifications Product Identification The following table summarizes Fiber Optic Repeater part numbers and applications: Part Number Network Application Mounting Method Power (Nominal) 490NRP253 Modbus Plus Point-to-Point Panel or Shelf 115/230 Vac, 24 Vdc 490NRP254 Modbus Plus Bus and Line Drop Panel or Shelf 115/230 Vac, 24 Vdc NWFR85D200 Modbus Plus Bus and Line Drop 19 in Rack 125/24 Vdc 490NRP954 Remote I/O Bus and Line Drop Panel or Shelf 115/230 Vac, 24 Vdc NWFR89D200 Remote I/O Bus and Line Drop 19 in Rack 125/24 Vdc Except for their operating power and mounting methods, Modbus Plus repeater models 490NRP254 and NWFR85D200 are identical, and Remote I/O models 490NRP954 and NWFR89D200 are identical. System Specifications Data Rate, Modbus Plus Data Rate, Remote I/O Electrical Interface Optical Interface Pulse Width Distortion/Jitter Bit Error Rate Wavelength Power Loss Budget (includes 3dB of system Margin) Maximum Distance for point to point connection 1 Mbit/sec for Modbus Plus with Bi Phase S encoded data Mbit/sec for Remote I/O with Manchester encoded data Modbus Plus connection via 9 pin D connector Remote I/O via F Connector ST type Connectors < 10 nsec 10 9 over specified Optical Receiver Dynamic Range 820 nm 50/125 µm fiber 7.0 db 62.5/125 µm fiber 11 db 100/140 µm fiber 16.5 db 2km over 50 µm 3.5 db/km 3km over 62.5 µm 3.5 db/km 3km over 100 µm 5 db/km Reliability Service Life 5 years 30 Fiber Optic Repeaters User s Guide MTBF 50,000 hours 30 C, assuming fixed ground and component stress within maximum specifications GM FIBR OPT
34 Power Requirements (AC/DC Models) AC Input VAC 120 ma VAC 60 ma DC Input VDC 300 ma AC Internal Fuse Rating V V Power Requirements (DC/DC Models) DC Input VDC VDC VDC 300 ma Retention on Power Loss Inrush Current Ground Leakage Remains in regulation > 10 ms after removal of power 6 A 125 VDC VDC Optical Transmitter Specification Optical Power (Measured with 1m Test fiber) Rise/Fall Time Silence or OFF Leakage dBm average power in 50/125 µm Fiber cable dBm average power in 62.5/125 µm Fiber cable dBm average power in 100/140 µm Fiber cable 20 nsec or better 43 dbm Optical Receiver Specification Receiver Sensitivity Dynamic Range Directed Silence 30dB/m average power 20 db 36 db Environmental Specification Operating Temperature Storage Temperature Humidity 0 to 60 C 40 to + 85 C 10% 95% non condensing Radiated Susceptibility mhz, 10 V/m (IEC 801-3, level 3) Surge Withstand, Fast Transient 2 kv, 1 kv on I/O (IEC 801-4, level 3) Surge Withstand, Oscillatory Wave 2.5 kv (IEEE 472). (Surge Withstand tests into 50 ohms using V-3300 Generator, corresponds to levels twice as high into open circuit) Surge Transients 2 kv (IEC 801-5, level 3) Electrostatic Discharge 8 kv, ten discharges (IEC 801-2, level 3) GM FIBR OPT Fiber Optic Repeaters User s Guide 31
35 1.14 Glossary attenuation The decrease in magnitude of power of a signal in transmission between points. A term used for expressing the total losses on an optical fiber consisting of the ratio of light output to light input. Attenuation is usually measured in decibels per kilometer (db/km) at a specific wavelength. The lower the number, the better the fiber. Typical multimode wavelengths are 850 and 1300 nanometers (nm); single mode, at 1300 and 1550 nm. NOTE: When specifying attenuation, it is important to note if it is nominal or average, room temperature, value or maximum over operating range. bandwidth A measure of the information carrying capacity of an optical fiber, normalized to a unit of mhz/km. Fiber bandwidth depends on the length of the fiber, and is usually expressed in mhz/km, even though the length dependence is not linear for multimode fibers. bit period The time required to define a data bit at a particular bit rate. [For Modbus Plus, 1 mbit results in 1/Bit Rate = 1/1 x 10 6 = 10 6 = 1 msec. For Remote I/O, 1/1.544 x 10 6 =.648 µsec = 648 nsec.] cladding The material surrounding the core of an optical waveguide. The cladding must have a lower index of refraction in order to steer the light in the core. connector A mechanical device used to align and join two fibers together to provide a means for attaching and decoupling it to a transmitter, receiver or another fiber. Commonly used connectors include the FC, FCPC, Biconic, ST Connector Compatible, D4, SMA 905 or 906. core The central region of an optical fiber through which light is transmitted. decibel (abbr. db) Unit for measuring the relative strength of a signal. digital A data format that uses two physical levels to transmit information. A discrete or discontinuous signal. dispersion The cause of bandwidth limitations in a fiber. Dispersion causes a broadening of input pulses along the length of the fiber. Three major types are: (a) mode dispersion caused by differential optical path lengths in a multimode fiber; (b) material dispersion caused by a differential delay of various wavelengths of lights in a waveguide material; and (c) waveguide dispersion caused by light traveling in both the core and cladding materials in single mode fibers. fiber A thin filament of glass. An optical waveguide consisting of a core and a cladding which is capable of carrying information in the form of light. fiber optics Light transmission through optical fibers for communication or signalling. graded index Fiber design in which the refractive index of the core is lower toward the outside of the fiber core and increases toward the center of the core; thus, it bends the rays inward and allows them to travel faster in the lower index of refraction region. This type of fiber provides high bandwidth capabilities. link A fiber optic cable with connector attached to a transmitter (source) and receiver (detector). 32 Fiber Optic Repeaters User s Guide local area network (abbr. LAN) A geographically limited communications network intended for the local transport of data, video and voice. GM FIBR OPT
36 mechanical splicing Joining two fibers together by mechanical means to enable a continuous signal. Elastometric splicing is one example of mechanical splicing. megahertz (abbr. MHz) A unit of frequency that is equal to one million hertz. micron (abbr. µm) Another term for micrometer. One millionth of a meter. 10exp 9meter. mode A term used to describe a light path through a fiber, as in multimode or single mode. modulation Coding of information onto the carrier frequency. This includes amplitude, frequency, or phase modulation techniques. multimode fiber An optical waveguide in which light travels in multiple modes. Typical core/cladding sizes (measured in microns) are 50/125, 62.5/125, and 100/140. nanometer (abbr. nm) A unit of measurement equal to one billionth of a meter. 10exp 9 meters. numerical aperture The number that expresses the light gathering power of a fiber. point to point A connection established between two specific locations, as between two buildings. repeater A device which consists of a transmitter and receiver or transceiver, used to amplify a signal to increase the system length. receiver An electronic package which converts optical signals to electrical signals. scattering A property of glass which causes light to deflect from the fiber and contributes to losses. source The means used to convert an electrical information carrying signal to a corresponding optical signal for transmission by fiber. the source is usually a Light Emitting Diode (LED) or Laser. splicing The permanent joining of fiber ends to identical or similar fibers, without the use of a connector. See also fusion splicing and mechanical splicing. star coupler Optical component which allows emulation of a bus topology in fiber optic systems. step index fiber Optical fiber which has an abrupt ( step ) change in its reflective index, due to a core and cladding that have different indices or refraction. Typically used for single mode. transmitter An electronic package which converts an electrical signal to an optical signal. wavelength The distance between the same point on adjacent waves. GM FIBR OPT Fiber Optic Repeaters User s Guide 33
Network Design. Yiannos Mylonas
Network Design Yiannos Mylonas Physical Topologies There are two parts to the topology definition: the physical topology, which is the actual layout of the wire (media), and the logical topology, which
Gigabit Switching Ethernet Media Converters - Product User Guide
Gigabit Switching Ethernet Media Converters - Product User Guide PL0338 Issue3 Introduction These Tyco Electronics Gigabit Media Converters translate between 1000Base-T copper and 1000Base-X fiber optic
SECTION 13421 PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL. 1.01 Summary. A. Section Includes:
SECTION 13421 PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL 1.01 Summary A. Section Includes: 1. The ISS shall furnish all labor, materials, equipment, services and incidentals
OPT-700 - SERIAL TO FIBER OPTIC CONVERTER
USER S MANUAL OPT-700 - SERIAL TO FIBER OPTIC CONVERTER JUL / 05 OPT-700 VERSION 1 TM FOUNDATION OPT700ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date
2-Pair HDSL1 Adtran Fiber Optic Link System
ISSUE 2 June 01, 2004 Data Sheet #37 2-Pair HDSL1 Adtran Fiber Optic Link System Contents 1. General. 1 2. Application... 2 3. Housings.. 2 4. Installation 3 5. Provisioning. 5 6. LED Indicators. 6 7.
F2400 FOM II Series Fiber Optic Modem Technical Manual
F2400 FOM II Series Fiber Optic Modem Technical Manual T1 Revision B Copyright April 2003 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com A030430283T PROPRIETARY DATA All data
The following terms are defined within the context of the fiber optic industry
The following terms are defined within the context of the fiber optic industry Adapter A mechanical media termination device designed to align and join fiber optic connectors. Often referred to as coupling,
Attaching the PA-A1-ATM Interface Cables
CHAPTER 4 Attaching the PA-A1-ATM Interface Cables To continue your PA-A1-ATM port adapter installation, you must attach the port adapter cables. The instructions that follow apply to all supported platforms.
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation
Stand Alone POTS Fiber Optic System P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit Description & Installation Printed in USA 09/11 TO466 Rev. A Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply
Cabling & Test Considerations for 10 Gigabit Ethernet LAN
Introduction Current communication data rates in local networks range from 10/100 megabits per second (Mbps) in Ethernet to 1 gigabit per second (Gbps) in fiber distributed data interface (FDDI) and Gigabit
Module 13 : Measurements on Fiber Optic Systems
Module 13 : Measurements on Fiber Optic Systems Lecture : Measurements on Fiber Optic Systems Objectives In this lecture you will learn the following Measurements on Fiber Optic Systems Attenuation (Loss)
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
Perle 10/100 Ethernet Media Converters
Perle 10/100 Ethernet Media Converters Installation Guide S-110-XXXXXX S-110-XXXXXX-XT P/N 5500302-16 (Rev B) Overview This document contains instructions necessary for the installation and operation of
HP ProCurve High-Speed Transceivers Installation Guide
HP ProCurve High-Speed Transceivers Installation Guide Introduction The HP ProCurve High-Speed Transceivers can be installed into a number of HP ProCurve networking devices to provide 100 Mbps and 1000
FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty.
Whale 3 DC Servo drive User Manual and Installation Guide Contents 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. 2. Electric specifications. 2.1.Operation ranges. 3. Connections
Module 5. Broadcast Communication Networks. Version 2 CSE IIT, Kharagpur
Module 5 Broadcast Communication Networks Lesson 1 Network Topology Specific Instructional Objectives At the end of this lesson, the students will be able to: Specify what is meant by network topology
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
FOM-5A, 6A. Asynchronous Fiber Optic Modem
FOM-5A, 6A Asynchronous Fiber Optic Modem FEATURES Asynchronous transmission at up to 19.2 kbps Transmission range up to 3 km (1.8 mi), regardless of data rate Full- or half-duplex Transfers one control
Model GS7000 4-Port Node 1 GHz with 40/52 MHz split
Model GS7000 4-Port Node 1 GHz with 40/52 MHz split The Model GS7000 4-Port Node is our latest generation 1 GHz optical node platform and utilizes a completely new housing designed for optimal heat dissipation.
Single Port Gigabit Ethernet Media Converter Board (P/N 201350-xxx) User s Manual And Troubleshooting Guide
Single Port Gigabit Ethernet Media Converter Board (P/N 201350-xxx) User s Manual And Troubleshooting Guide August 12, 2009 Rev C Moog Components Group Springfield Operations 750 West Sproul Road Springfield,
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
IRT Eurocard. Types DAX-3200
I R T Electronics Pty Ltd A.B.N. 35 000 832 575 26 Hotham Parade, ARTARMON N.S.W. 2064 AUSTRALIA National: Phone: (02) 9489 3744 Fax: (02) 9439 7439 International: +61 2 9439 3744 +61 2 9439 7439 Email:
FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK
FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK Field busses are industrial control systems using Programmable Logic lers (PLC) to control and manage field devices found in industrial environments. The communication
Perle Protocol Transparent Media Converter Modules
Perle Protocol Transparent Media Converter Modules Installation Guide C-4GPT-DSFP CM-4GPT-DSFP Part# 5500335-10 Overview This document contains instructions necessary for the installation and operation
LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions
LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions Description The LS-1 Series of tungsten halogen light sources are versatile, white-light lamps optimized for use in the
Fiber Optic Specifications
Fiber Optic Specifications All Fiber Optic shall be Corning Altos Single Mode OS1 Outdoor Loose Tube Gel Free Cable Corning Fiber Products only will be accepted and no substitutions or alternates will
What are Fibre Optics?
Fibre Optics Fibre Optics? Fibre optics (optical fibres) are the guiding channels through which light energy propagates. These are long, thin strands of very pure glass about the diameter of a human hair
10Gb/s SFP+ LRM 1310nm FP with PIN Receiver 220meters transmission distance
Feature 10Gb/s serial optical interface compliant to 802.3aq 10GBASE-LRM Electrical interface compliant to SFF-8431 specifications for enhanced 8.5 and 10 Gigabit small form factor pluggable module SFP+
8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide
8-port 10/100Base-TX +2-port 100Base-FX Switch User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by
Designing Fiber Optic Systems David Strachan
Designing Fiber Optic Systems David Strachan Everyone knows that fiber optics can carry a huge amount of data. There are more benefits to using fiber optics in broadcast applications than you might realize.
USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)
USER MANUAL MODEL 2300M SERIES OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M) An ISO-9001 Certified Company Part# 07M2300M Doc# 077321U Rev. A Revised 4/14/03 SALES OFFICE (301) 975-1000
FlexPoint T1/E1 Copper to Fiber Line Driver
BLACK BOX NETWORK SERVICES MT660A-MM MT661A-SM MT660A-MM-E MT661A-SM-E FlexPoint T1/E1 Copper to Fiber Line Driver CUSTOMER Order toll-free in the U.S.: Call 877-877-BBOX SUPPORT (outside U.S. call 724-746-5500)
ABB RTU560A Series CMU & Modules
ABB RTU560A Series CMU & Modules 1KGT 150 648 V1.02 March 4, 2012 Slide 1 Contents RTU560A rack solutions March 4, 2012 Slide 2 560CSR01 Available for wall mounting and swing frame Supports redundant power
Troubleshooting and Auto-Negotiation Features for IMC Networks Media Conversion Products
Troubleshooting and Auto-Negotiation Features for IMC Networks Media Conversion Products Table of Contents Introduction...................................................................... 1 About Link
The Conversion Technology Experts. Fiber Optics Basics
The Conversion Technology Experts Fiber Optics Basics Introduction Fiber optic technology is simply the use of light to transmit data. The general use of fiber optics did not begin until the 1970s. Robert
DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)
Features: DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES) PATENT NUMBERS: CANADA 2,494,133, USA 7095931, 7295731 AND CHINA 1672073 Telcordia GR-468 qualified Available in versions for any wavelength
ST Series POWER SUPPLIES USER INSTRUCTIONS
Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional
FCC COMPLIANCE STATEMENT
MEDIA CONVERTER Fiber to UTP Ethernet Media Converter ET90110SC ET90110ST Instruction Guide * Actual product may vary from photo Revised: December 6, 2002 The Professionals Source For Hard-to-Find Computer
Allen-Bradley/Rockwell
MANUFACTURER DATA SHEET High Speed Counter Manufacturer: Allen-radley/Rockwell Model Number: 1746-HSCE See www.geomartin.com for additional PDF datasheets Martin Part Number: E-014901-03 VendorPartNumber:
Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011
Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.
RLH 2 Wire Digital Phone Fiber Link Card System
RLH Industries, Inc. The leader in rugged fiber optic technology. USER GUIDE! Unconditional Lifetime Warranty U-008 2014C-0924 RLH 2 Wire Digital Phone Fiber Link Card System CARD INSTALLATION INFORMATION
Fibre Channel Fiber Cabling
OVERVIEW This paper will discuss the Fibre Channel standards for fiber cables at both 1Gb and 2Gb speeds, and also some discussion of departures from standard. Items discussed will be cable types, plug
USER GUIDE. 2 Channel POTS Mux DIN Fiber Link System. Introduction SYSTEM INSTALLATION INFORMATION. The leader in rugged fiber optic technology.
The leader in rugged fiber optic technology. USER GUIDE! Lifetime Warranty U-04 015A-01 Channel POTS Mux DIN Fiber Link System SYSTEM INSTALLATION INFORMATION Introduction The Channel POTS Mux DIN Fiber
TACTICAL FIBER OPTIC MODEMS U.S. Army and ANSI Standards
This data sheet contains controlled technical data that has been cleared for public release by the U.S. Government under ITAR Exemption 22CFR 125.4(b)(13). TACTICAL FIBER OPTIC MODEMS U.S. Army and ANSI
Perle 10/100/1000 Ethernet Media Converter Module
Perle 10/100/1000 Ethernet Media Converter Module Installation Guide C-1110-XXXXX CM-1110-XXXXX C-1110-SFP CM-1110-SFP Unmanaged Module Managed Module Unmanaged Module Managed Module P/N 5500308-21 Overview
Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM
Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability is assumed
IRT Eurocard. Type DAX-3206. Audio Extractor for 270 Mb/s SDI
I R T Electronics Pty Ltd A.B.N. 35 000 832 575 26 Hotham Parade, ARTARMON N.S.W. 2064 AUSTRALIA National: Phone: (02) 9439 3744 Fax: (02) 9439 7439 International: 61 2 9439 3744 61 2 9439 7439 Email:
Optimux-34, Optimux-25
Data Sheet Optimux-34, Optimux-25 Up to 16 E1/T1 links and high-speed data or Ethernet traffic multiplexed into fiber optic uplink E3 copper uplink for Optimux-34 Single-mode, multimode, single-mode over
SYSTEM 4C. C R H Electronics Design
SYSTEM 4C C R H Electronics Design SYSTEM 4C All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, A outputs. Independent 25
FIRERAY 2000 Installation Guide
FIRERAY 2000 Installation Guide Features Range 33ft to 330 ft. 24Vdc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or Automatic reset System Description
Guide to Industrial Fiber Optics
Guide to Industrial Fiber Optics All rights reserved. No part of this manual may be reproduced, photocopied, stored on a retrieval system or transmitted without the express prior consent of Relcom, Inc.
10-3. SYSTEM TESTING AND DOCUMENTATION
10-3. SYSTEM TESTING AND DOCUMENTATION System testing and documentation must cover pre-installation testing, sub-system testing, fiber optic cable testing, video link testing, data link testing, acceptance
Amplified High Speed Fiber Photodetectors
Amplified High Speed Fiber Photodetectors User Guide (800)697-6782 [email protected] www.eotech.com Page 1 of 7 EOT AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE Thank you for purchasing your Amplified
Short Range Wireless Switch System Handheld 8 Installation and Operations Guide
Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...
Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3
Data Sheet Optimux-45, Optimux-45L Up to 28 T1 or 21 E1 channels multiplexed into a single 45 Mbps data stream Any Traffic over Fiber Combination of T1 and E1 channels Transmission over coax or fiber optic
GLOBAL COLLEGE OF ENGINEERING &TECHNOLOGY: YSR DIST. Unit VII Fiber Optics Engineering Physics
Introduction Fiber optics deals with the light propagation through thin glass fibers. Fiber optics plays an important role in the field of communication to transmit voice, television and digital data signals
16/32 Channel 1U Rack Mount CCTV Power Supply
16/32 Channel 1U Rack Mount CCTV Power Supply Manual PH-A3224-GUQ Shown 16-Channel 32-Channel PTC PH-A1612-PUQ PH-A3224-PUQ Glass Fuse PH-A1612-GUQ PH-A3224-GUQ Industrial design 12 Amp 3 Amps per channel
Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips
Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier Refer to the Lifestyle SA-2 & SA-3 Amplifier service manuals, part number 271720 for schematics, PCB layouts and parts lists. Preventative Repair Measures
ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide
31007950 7/2009 ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide 7/2009 31007950.02 www.schneider-electric.com NOTICE Read these instructions carefully, and look at the equipment to become
LDG DTS-4/4R Desktop Coaxial Switch / Remote
LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 [email protected] www.ldgelectronics.com
Technical Bulletin. Guidelines For Testing And Troubleshooting Fiber Optic Installations
The Fiber Optic Association, Inc. 1119 S. Mission Road #355, Fallbrook, CA 92028 1-760-451-3655 Fax 1-781-207-2421 Email: [email protected] http://www.thefoa.org Technical Bulletin Guidelines For Testing
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
Using installed Fieldbus Wiring to carry Ethernet Communications
Using installed Fieldbus Wiring to carry Ethernet Communications Modbus Plus, Data Highway, GE Genius, Profibus, ControlNet, DeviceNet, InterbusS and many other RS232 or RS4422 cables Key Issues when upgrading
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
INSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
OPTICAL FIBERS INTRODUCTION
OPTICAL FIBERS References: J. Hecht: Understanding Fiber Optics, Ch. 1-3, Prentice Hall N.J. 1999 D. R. Goff: Fiber Optic Reference Guide (2 nd ed.) Focal Press 1999 Projects in Fiber Optics (Applications
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
Single Channel Loop Detector
Single Channel Loop Detector Model - LD100 Series The LD100 is a single channel inductive loop detector designed for parking and access control applications. The detector is connected to an inductive loop
Ethernet over VDSL2 Converter VC-201A / VC-204
Ethernet over VDSL2 Converter VC-201A / VC-204 User s Manual Trademarks Copyright PLANET Technology Corp. 2009 Contents subject to revision without prior notice. PLANET is a registered trademark of PLANET
SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C37.94. Fiber Service Units
SOLUTIONS FOR AN EVOLVING WORLD T1/E1 and C37.94 Fiber Service Units T1/E1 & C37.94 1 April 2013 Your world is changing and so are we. At RFL, we know your needs change much faster than your infrastructure.
Connecting to the Internet
Connecting to the Internet Connecting the Gateway to the Internet Configuration of TCP/IP Protocol Installing the USB Drivers Connecting Ethernet Network Devices Connecting USB Network Devices Connecting
Optimux-134, Optimux-125
Data Sheet Optimux-134, Optimux-125 Up to 16 E1/T1 links, full bandwidth 100 Mbps Ethernet traffic and high-speed data multiplexed into fiber optic uplink 25/34 Mbps or 125/134 Mbps operation s Single-,
Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages)
Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages) 1. Be sure that your kit includes all the parts shown in the Check the Equipment section
The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects
The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects White Paper /7/0 Executive Summary Now that the TIA/EIA-568-B.- Category 6 Copper Cabling
Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports
Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports (800-0037) Doc. PUBTPASXSFPU Rev., 07/08 Contents Introduction.... Key Features... Unpacking and Inspection....3 Product
Setting Up and Testing the MAX Hardware
Page 1 of 12 Setting Up and Testing the MAX Hardware This chapter covers these topics: Planning the hardware installation Inserting an expansion card Setting up the hardware Connecting to input power Connecting
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.
ACS-101 Amplified Broadband UHF Combiner-Splitter General Description The ACS-101 (Antenna Combiner Splitter 10 to 1) is an amplified and filtered broadband splitter-combiner. It allows up to 10 base stations
AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE
AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE Thank you for purchasing your Amplified High Speed Fiber Photodetector. This user s guide will help answer any questions you may have regarding the
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
Installation Guide for Dolphin PCI-SCI Adapters
Installation Guide for Dolphin PCI-SCI Adapters Part Number: DI950-10353 Version: 1.5 Date: December 7th 2006 Dolphin Interconnect Solutions ASA Olaf Helsets vei 6 P.O.Box 150, Oppsal N-0619 Oslo, Norway
Keysight N4877A Clock Data Recovery and Demultiplexer 1:2
Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 Getting Started Getting Started with the Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 You only need a few minutes to get started
Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data
Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data Copyright 2007, American Fibertek, Inc. 0411JD Table of Contents Functional Description...3
Cisco SFP Optics for Gigabit Ethernet Applications
Cisco SFP Optics for Gigabit Ethernet Applications The industry-standard Cisco Small Form-Factor Pluggable (SFP) Gigabit Interface Converter is a hot-swappable input/output device that plugs into a Gigabit
Optimux-134, Optimux-125
Optimux-134, Optimux-125 Up to 16 E1/T1 links, full bandwidth 100 Mbps Ethernet traffic and high-speed data multiplexed into fiber optic uplink 34/25 Mbps or 134/125 Mbps operation s Single-, multi, single-
SEL Fiber-Optic Products and Applications
Fiber-Optic Products and Applications SEL Fiber-Optic Transceivers Provide Simple, Reliable, and Economical Communications Solutions Major Features and Benefits SEL fiber-optic devices provide isolation
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...
OPTICAL FIBER repeaters/ isolators
OPTICAL FIBER repeaters/ isolators FUNCTINALITY AND RELIABILITY' Optical Fiber converters give the possibilità to extend on Optical Fiber (also at the same time) every type of network/bus (LAN/Ethernet,
Operating Instructions
VMD202 Vehicle Motion Detector Operating Instructions CAUTIONS AND WARNINGS Never use the VMD202 as a safety reversing or presence detection system. The VMD202 requires that a vehicle be moving for detection.
Operation and Installation Manual
Operation and Installation Manual RCM-10 Remote Control Monitor and RSM-10 Remote Status Monitor for the CNA-100 & CNA-200 Automations Revision 1.1 9/98 WARRANTY INFORMATION The RCM-10 Remote Control
Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications
Data Sheet Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications The industry-standard Cisco Small Form-Factor Pluggable (SFP) Gigabit Interface Converter is a hot-swappable input/output
Moxa EtherDevice Switch
Moxa EtherDevice Switch EDS-205 Hardware Installation Guide Third Edition, June 2008 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited. P/N: 1802002050000 Overview The
Perle Fast Fiber to Fiber. Media Converters
Perle Fast Fiber to Fiber Media Converters Installation Guide S-100MM-XXXXX P/N 5500312-10 (Rev A) Overview This document contains instructions necessary for the installation and operation of the Perle
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
5-port 10/100Base-TX Industrial Switch (314500) User s Guide
5-port 10/100Base-TX Industrial Switch (314500) User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by
SYSTEM 45. C R H Electronics Design
SYSTEM 45 C R H Electronics Design SYSTEM 45 All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, & A outputs. Independent 25