1 Product Data Sheet Model 700 Daniel Danalyzer Model 700 Gas Chromatograph Danalyzer Model 700 Gas Chromatographs offer the broadest range of analysis options available today in a fieldmount gas chromatograph (GC). Whether it is heating value measurement, trace contaminant monitoring, pipeline integrity, or product quality/process control, the Danalyzer Model 700 is flexible enough to meet your analysis needs. Based on the same proven technology and software as the Danalyzer Model 500 series, the Danalyzer Model 700 design offers superior reliability and precision, lower installation and operating costs, greater application flexibility, and unmatched measurement performance. Features and Benefits One package for fiscal metering or gas quality Custody transfer analysis from C 6 + to C 9 + Contaminant monitoring - trace H 2 S, CO 2, oxygen, etc. Combine measurements and reduce analysis cost Oxygen (0-2%) Trace H 2 S (0-50 ppm) CO 2 (as fast as 90 seconds) Helium/Hydrogen (0-10%) Hydrocarbon Dew Point (±2 C) Reduced installation costs 24 VDC power standard Integrated controller electronics Pipe-mount, wall-mount, or floor mount Unmatched measurement performance Highest stated precision ±0.25 BTU/1000 for broad ambient temperature C 6 + analysis in -18 to 54 C (0-130 F) environmental conditions Wide dynamic range from percent to trace level components Reliable performance over broad ambient temperatures -30 C to 60 C ( F) Easy to use Compatible with Danalyzer Model 500 Gas Chromatographs MON2000 software setup and diagnostics Identical setup and operation for all models no additional training Lower operation and maintenance costs No shelter or instrument air required Low helium and power consumption Longest gas chromatograph valve and column warranties available Visit us online at
2 APPLICATIONS Standard Natural Gas Applications We have made our most popular energy and gas quality applications standard. Applications may vary by components of interest, analysis time, reduced hardware (economics), or improved precision. Choose the one that is right for you, or we will create one that is customized for your specific application. Energy Measurement (to C6+ and C9+) The Danalyzer Model 700 offers applications for energy measurement from C6+ hydrocarbon ranges to C9+ hydrocarbon ranges. Calculations based on GPA 2145 or ISO 6976 standards can be provided. Standard Measurement Ranges Methane 65 to 100-mole % Ethane 0 to 20-mole % Propane 0 to 10-mole % N-Butane 0 to 5-mole% Iso-Butane 0 to 5-mole % N-Pentane 0 to 1 mole % Iso-Pentane 0 to 1 mole% Neo-Pentane 0 to 1 mole% Hexane+ 0 to 0.7-mole% Nitrogen 0 to 20 mole % Carbon Dioxide 0 to 20 mole% Hexanes 0 to 1 mole% Heptanes 0 to 1 mole% Octanes 0 to 0.5 Mole% Nonane+ 0 to 0.5 mole% C 6 + C 9 + Hydrocarbon Dew Point Monitoring Accurate and reliable hydrocarbon dew point determination can now be made as an option to any C 9 + extended analysis application. The DewCalc Hydrocarbon Dew Point software is completely integral to the gas chromatograph and provides dew point temperatures and cricondentherm for up to four userentered pressures. Alternately, real-time dew point results can be provided by using analog or Modbus inputs from another device. DewCalc software is loaded with features, including: Choice of two equations of state, Peng-Robinson or Soave-Redlich-Kwong Library of 93 hydrocarbon compounds for detailed breakdown of C9+ fraction DewCalc report with analysis results and factors used Custom Applications If our standard applications do not fit your needs, the Danalyzer Model 700 can be customized to meet your measurement requirements. Simply submit a completed application data sheet found at the end of this data sheet with your request, or ask our Application Engineers for assistance. Gas Quality Analysis Natural gas contaminants reduce pipeline integrity over time. Most contaminants can be easily measured in the Model 700 for online quality assurance. Contaminant monitoring can be combined with energy measurements for complete custody transfer analysis. To the extent possible, these combined applications utilize independent gas chromatograph valves, detectors, and columns, for each primary measurement. This technique offers greater reliability, increased speed, and easier troubleshooting. This application approach also makes field upgrades and re-applications in the Danalyzer Model 700 easy by minimizing internal piping changes. Page 2
3 Standard Danalyzer Applications and Repeatability Application Code Application Name Components Measured Analysis Time % Controlled temperature 604 Standard BTU/CV C1 to C6+, CO2, N2 4 min ± ± GT Gas Turbine BTU/CV/ C1 to C6+, CO2, N2 2 min ±0.05 ±0.1 Density TS2 Gas Quality (H2S) Trace H2S (3-30 ppm) 90 sec ±2 ppm ±3 ppm LF8 Landfill Gas BTU/CV C1, N2, CO2, O2 8 min ±0.1 ±0.2 LF3 Landfill Gas (mole-sieve) C1, N2, CO2, O2 3 min ±0.1 ±0.2 % Repeatability Over F 6PS Std C6+ with % H2S C1 to C6+, CO2, N2, H2S 10 min ±0.05 ±0.1 (%) 6PO Std C6+ with % Oxygen C1 to C6+, CO2, N2, O2 10 min ±0.05 ±0.1 6HH Std C6+ with Helium/ Hydrogen C1 to C6+, CO2, N2, He/ H2 5 min ±0.05 ±0.1 6TS C6+ with ppm H2S C1 to C6+, CO2, N2, H2S 7 min ±0.0125/±2 ppm ±0.015/±3 ppm (ppm) 905 Std C9+ C1 to C9+, CO2, N2 5 min ±0.025 ±0.05 HC9 Std C9+ and Hydrocarbon C1 to C9+, CO2, N2 5 min ±0.025 ±0.05 Dewpoint 712 Standard C7+ BTU/CV C1 to C7+, CO2, N min ±0.025 ±0.05 SUPERIOR PERFORMANCE The Danalyzer Difference Modular Analytical Oven An element that is key to the Danalyzer Model 700 Gas Chromatograph s application flexibility is the modular analytical oven. Using field-proven Danalyzer valves, columns, and detectors, the analytical oven has been redesigned to make it modular and scalable. Six- or ten-port valves and detectors mount to a triangular kiosk block which facilitates valve heating and pneumatic actuation. Three temperature control zones and up to three valves and two detectors operating independently provide extreme application flexibility and range. All components in the oven are completely accessible and serviceable in the field. Gas Chromatograph Valves At the heart of the Danalyzer s superior reliability are the six- and ten-port diaphragm/piston gas chromatograph valves. These pneumatic valves are guaranteed for the life of the gas chromatograph and specified to operate over 5 million times between service. By minimizing internal movement (1/1,000 inch) of the pistons, which never come in contact with sample, abrasive mechanical wear is virtually eliminated. This unique double-diaphragm design removes the need for all springs, o-rings, or lubrication. Valve service is performed by replacing a cost-effective diaphragm set, normally completed in less than 10 minutes. Detectors The thermal conductivity detector (TCD) is the detector of choice for most applications due to its universal response to all compounds. The TCD found in the Danalyzer Model 700 Gas Chromatograph is able to go well beyond the normal measuring ranges seen in other designs by being able to do many applications Page 3
4 with low parts-per-million measurement requirements. This greatly simplifies the gas chromatograph design when a simple and rugged TCD can be used. The flame ionization detector (FID) for trace hydrocarbon measurements and the flame photometric detector (FPD) module for trace sulfur measurements are also available. Micro-packed Columns Danalyzer micro-packed columns offer a superior combination of features found in both capillary and conventional packed columns speed, sharp peak resolution, and low carrier gas consumption. In addition, this unique design provides for greatly extended column life and the longest warranty available on the market (five years on the standard C 6 + natural gas set). Stream Switching Module The Danalyzer Gas Chromatograph offers an internal sample stream switching module. Available in four- or eight-stream versions, this module utilizes the same helium-rated 24-volt solenoids used in the analytical oven. It is temperature-controlled for operation above the sample dewpoint. For applications with widely varying stream composition, double block and bleed configuration is optionally available. Local Indication and Operation Panel Analyzer health and valve status can be viewed through the glass cover of the lower enclosure. The panel displays green (OK), yellow (warning), and red (failure) LEDs, along with LEDs for all gas chromatograph valve actuations, power, and CPU health. Each valve can be actuated manually for simplified troubleshooting and fast system purging after maintenance. Touch Key Local Operator Interface (Optional) The Model 700 local operator interface (LOI) allows for maintenance and operation of a Model 700 without a laptop or PC. The LOI is a state-of-the-art high resolution color display that is touch key infrared activated and supports all core GC operations. Features of the LOI include: - Color LCD with QVGA (320 x 240 pixels) resolution - ASCII text and graphics modes - Auto-backlighting (adjustable) - 8 infrared-activated touch keys and screen saver - Eliminates external magnetic pen requirement - Maintains the Model 700 hazardous area classifications - Operates in the same ambient temperatures as the base Model Complete GC status, control and diagnostics, including full chromatogram display CONTROLLER ELECTRONICS AND COMMUNICATIONS Modular Electronics The controller electronics, option cards, and field termination boards are packaged conveniently in the lower enclosure of the Danalyzer Model 700. Separate power and output connections are made through this enclosure. Compatible Electronics and Software The Danalyzer Model 700 uses the same CPU board as the Danalyzer Model 500, thus making features, options, and operation nearly identical. No new training is required. Model 700 shown with optional touch-key LCD LOI Page 4
5 Data archiving and reports The Danalyzer Model 700, with expandable solid-state memory, virtually eliminates the need for external data storage. Every analysis is time/date stamped and archived, for retrieval via the MON2000 software. Pre-configured reports can be displayed, printed, and/ or stored internally. Results can be trended directly or exported easily in ASCII format. Security - three levels of password protected security configurable to read/write or read only for third party access Audit logs - data and event logging fully conforms to API report 21.1 for metering audit purposes and backup to primary systems (flow computer, SCADA, DCS) Event logs - a continuous record of all operator changes, with time, date, and operator name recorded Alarm logs - a continuous record of all historical alarms, time/date stamped with alarm state and description Maintenance log - a scratch pad for keeping track of maintenance or testing performed on the gas chromatograph system Standard reports include: Average reports - hourly, 24-hr., weekly, monthly and variable averages Analysis reports - physical property calculations by component and group for analysis and alarms Raw data report - retention times, peak areas, detector number, method, integration start/stop, and peak width for the analysis Calibration report - raw component data, new response factors, retention times, and deviation for last calibration Final calibration report - results of final calibration, response factor and retention time adjustments ENVIRONMENTAL CHAMBER TESTING We provide the most thorough gas chromatograph testing in the world. Prior to shipment, we test nearly every Danalyzer Model 700 in our walk-in environmental test chambers, where temperatures are cycled between 0 F and 130 F for a minimum of 24 hours. This is all part of our commitment to provide analyzers that are capable of providing reliable measurements in the field. BTU Repeatability In Environmental Chamber Model 700 C 9+ Application - Pipeline Gas COLD RAMP COLD SOAK HOT RAMP HOT SOAK Archiving - the last 35 days of each analysis and 64 calibrations can be archived automatically by time/ date stamp. Last chromatogram stored for each sample and calibration stream. BTU o F 130 o F o F :00 1:07 2:14 3:21 4:28 5:35 Stated Repeatability (oven temperature): ±0.05% CV Repeatability as tested: ±0.0165% 6:43 7:50 8:57 10:04 11:11 12:18 13:25 14:33 15:40 16:47 17:54 19:01 20:08 21:16 22:23 ELAPSED TIME 17 Jan 04 Deg C Superior measurement stability in extreme climates is tested for every Model 700 Process Gas Chromatographs before it ships. Page 5
6 MON2000 SOFTWARE The Danalyzer Model 700 Gas Chromatograph is designed to operate unattended. If adjustments are needed, our exclusive MON2000 software allows complete control of your gas chromatographs either locally or remotely. From within MON2000, a user can: Review and modify analytical settings on one screen Upload and display multiple chromatograms on the screen for comparison Upload and trend any of the measured results Export data for use in other third-party applications Overlay multiple chromatograms for troubleshooting and calibration Check original calibration against last calibration The MON2000 software is Windows -based software designed to make analyzer configuration, maintenance and data collection easy. With intuitive drop-down menus and fill-in-the-blank tables, even new users can quickly navigate through the software. The MON2000 software can display both current and multiple archived chromatograms on the screen streamlining the time needed to perform routine analyzer maintenance. MON2000 also has a number of tools built in to help users manage their analyzers such as: Automatic recording of alarms in a log file Event logs that provide a continuous record of all operator changes with time and user name stored Maintenance log scratch pad for keeping track of maintenance or testing done Download and install the latest GPA 2145 and ISO 6976 physical property factors Data collected from the Danalyzer Model 700 can be stored and displayed in a wide range of options such as trend lines on the screen and logs automatically documenting all changes made to the gas chromatograph. Data can also be exported in formats compatible with most third-party Windows applications. Simple dropdown menus Connect to any GC with a mouse click Full featured chromatogram display Powerful Yet Simple MON2000 Software Summary of application event status and time Automatic listing of measured components Quickly add chromatograms to overlay Manually adjust X/Y scale Interactive cursur Display results Save chromatograms to hard drive Page 6
7 P Q R P Q R Product Datasheet ANALYZER NETWORKING AND DATA COMMUNICATION Danalyzer Gas Chromatographs can be configured in a number of networking and data communication schemes to meet the communication requirements of the natural gas industry. Options include modem, Ethernet, as well as multi-drop RS-485 networks. It is even possible to set up automatic polling for data collection if desired. Data communication options include simple analog and discrete signals as well as Modbus serial links. To preserve the integrity of the analysis data, all Danalyzer Model 700 Gas Chromatographs are capable of storing up to 35 days of analysis or calibration data in the event of loss of communication. All Danalyzer Gas Chromatographs are designed to operate unattended. Occasionally, adjustments to the analyzer analytical method or a review of possible alarms may be needed. Using our exclusive MON2000 software loaded on either a PC or laptop running Windows, you ll have complete control of your gas chromatographs either locally or remotely. Networking Flexibility Whether you want to network gas chromatographs throughout the plant or simply link a single gas chromatograph to a flow computer system, the Danalyzer Model 700 can be configured to handle most of the scenarios: Choice of Ethernet or RS-485 network Can use same network to connect Danalyzer Model 700, Model 500, and Model 1000 Gas Chromatographs Able to connect multiple PC workstations using MON2000 Connectivity to flow computer or SCADA systems using industry standard protocols such as Modbus and OPC Secure Modbus Connectivity For online gas chromatographs, Modbus continues to be the preferred choice to connect to a gas chromatograph network. Our Modbus design avoids the use of central interface cards or computers that can act as a single-point of failure in the Modbus link. Instead, the flow computer or SCADA system can talk directly to each gas chromatograph to gather the data needed. Furthermore, the register and coil addresses can be easily customized to meet the specific data structure of the flow computer or SCADA system. There is also a program built into the MON2000 workstation to test the Modbus link if troubleshooting is needed. Simplified Network Communications - Multiple serial ports with Ethernet option can be field configured to provide redundant data highways. MODEL 700 MODEL 700 MODEL 1000 INTERNET - RS 232C - RS 485/422 - ETHERNET OPTIONAL LAPTOP FOR LOCAL COMMUNICATION MODEL 500 PRINTER / LOGGER ETHERNET - UNLIMITED NUMBER OF GC S MODEL RS 232C - RS 485/422 - ETHERNET MON2OOO WORKSTATION DCS OPC SERVER MON2OOO WORKSTATION MODEL 700 OPC SERVER MODEL 1000 MODEL 700 REDUNDANT RS 485/422 UP TO 32 GC S MODEL 500 MODEL RS 232C - RS 485/422 - ETHERNET OPTIONAL LAPTOP FOR LOCAL COMMUNICATION MODEL RS 232C - RS 485/422 - ETHERNET MON2OOO WORKSTATION Page 7
8 ACCESSORIES We offer standard and custom gas chromatograph accessories to meet your installation and application requirements. Gas Chromatograph System Enclosures Complete range of gas chromatograph enclosure solutions ranging from simple sun-shields and cabinets to skids systems and shelters 3 - Sided Shelter API 14.1 compliant solutions with heating of sample lines and calibration gas Standard Auxiliary Equipment Sample probes / pressure regulators / filters for a wide range of sample handling requirements Carrier gas systems with dual manifold regulators for uninterrupted operation Calibration gases and heating blankets GAS CHROMATOGRAPH ACCESSORIES Laptop Computer Shelf mounts easily - folds down on side (PN ) Multi-stream Heated Sample Conditioning System Carrier Manifold "Condulet" Junction Box for quick laptop PC (db9 connector) access Custom-Engineered Sample Systems Any gas chromatograph is only as good as the quality of the sample it measures. Every sample system for Danalyzer Gas Chromatographs is custom-engineered for the specific requirements of the application. Common features include: Heated and open panel designs All components rated for the area classification Automatic calibration / validation available as an option Variety of sample probes to extract a reliable and stable sample Condulet Junction Box Laptop Computer Shelf Sample Probe Calibration Gas with Heating Blanket Page 8
9 Danalyzer Model 700 Gas Chromatograph CSA Certified Danalyzer GC, 6 or 10 port valves, single or dual detectors Ordering Matrix (must select only 1 option for each column) 77X C W DC 4 SN N S N S (example) Code Approvals C CSA A ATEX Code Mounting W Wall-mount P Pipe-mount F Floor-mount Code Power DC 24 VDC AC Universal 85 to 240 VAC Manuals: (one set included with each system) Hardware manual - P/N Software manual - P/N All Danalyzer Model 700 Gas Chromatographs must be crated for shipment. * Users with rich natural gas applications may require heated sample system ovens and sample transport tubing to insure that the sample is kept above its sample dew point. Consult the factory to determine if heated sample system is needed. Code Digital/Analog I/O 4 5 Digital In; 4 Digital Out; 4 Analog In; 4 Non-isolated Analog Out 8 5 Digital In; 4 Digital Out; 4 Analog In; 8 Analog Out, 4 Non-Isolated/4 Isolated 12 5 Digital In; 4 Digital Out; 4 Analog In; 12 Non-isolated Analog Out Code Serial Communications/Local Keypad-LCD SN Standard/no keypad - LCD {(2) RS232, (1) RS422/486 Factory/Field configurable} EN Extended/no keypad - LCD {(4) RS232, (2) RS422/486 Factory/Field configurable} Code Internal Modem and/or Ethernet N No Modem or Ethernet M Modem only E Ethernet only B Modem and Ethernet X Special (consult factory) Code Internal Stream Switching (Total max. # streams = sample + calibration streams) S4 Standard Up to 4 streams S8 Standard Up to 8 streams D4 Double block and bleed - Up to 4 streams D8 Double block and bleed - Up to 8 streams ES External stream switching - (consult factory) X Special (consult factory) Code Oven Assembly/Application 612 BTU/CV C 6 + / 12 min. 604 BTU/CD C 6 + / 4 min. 6GT BTU/CV C 6 + / 2 min./turbine TS2 Trace H 2 S / 3 min.* LF8 Landfill Gas / 8 min. LF3 Landfill Gas / 3 min. (mole-sieve) 6PS Std. C 6 + with % H 2 S 6PO Std. C 6 + with % Oxygen 6HH Std. C 6 + with Helium/Hydrogen 6TS C 6 + / 12 min and ppm H 2 S / 7 min.* 905 Std. C 9 + and HC Dew X Special Code Sample Conditioning (sample streams only) 1N 1 stream plate 1G 1 stream plate, with Fast Loop/Membrane Filter/Liq. Shut-off 2N 2 stream plate 2G 2 stream plate, with Fast Loop/Membrane Filters/Liq. Shut-off 3N 3 stream plate 3G 3 stream plate, with Fast Loop/Membrane Filters/Liq. Shut-off 4N 4 stream plate 4G 4 stream plate, with Fast Loop/Membrane Filter/Liq. Shut-off 5N 5 stream plate 5G 5 stream plate, with Fast Loop/Membrane Filter/Liq. Shut-off 6N 6 stream plate 6G 6 stream plate, with Fast Loop/Membrane Filter/Liq. Shut-off 7N 7 stream plate 7G 7 stream plate, with Fast Loop/Membrane Filter/Liq. Shut-off O Heated Sample System (Order Separately) X Special (consult factory) Code Application Software S Std. GPA 2172/GPA2145 I ISO 6976;1995 X Special (consult factory) Page 9
10 Product Application Datasheet Sheet Every Danalyzer Model 700 Gas Chromatograph is custom built for the specific application requested. To request a free quotation, simply fill out the information below and send it to your world area contact information located on the back cover of this datasheet. Name: Title: Company: Address: Your Reference #: Project Name: Process Unit: Stream Name(s): Hazardous Area Classification: Phone #: Fax #: Stream Composition Units Stream 1 Stream 2 Min Normal Max Measure Min Normal Max Measure (For more than two streams, make copies of this page) Stream Temperature Stream Pressure Stream Phase (vapor/liquid) Stream Contaminants Stream 1 Stream 2 Distance to GC from sample point Power: VAC ( ) 24 VDC ( ) Mounting: Wall ( ) Pipe ( ) Stand ( ) Data communication Analog output ( ) Modbus ( ) OPC ( ) Printer ( ) Modem ( ) Analyzer network: Ethernet ( ) RS-485 Multi-Drop ( ) Other options: Carrier Gas ( ) Calibration Gas ( ) Start-up ( ) Training Class ( ) Special Instructions: Page 10
11 Specifications Power: Standard: 24 VDC, ( VDC) Optional: VAC, Hz 80 watts start-up; 33 watts nominal Environment: -29 to 60 C (-20 to 140 F) Enclosure Protection Rating: IP66 and NEMA 4X Dimensions (without sample system): Wall-mount: 914mm H x 462mm W x 483mm D (36 H x 18.2 W x 19 D) Pipe-mount: 914mm H x 462mm W x 645mm D (36 H x 18.2 W x 25.4 D) Floor-mount: 1483mm H x 419mm W x 577mm D (58.4 H x 16.5 W x 22.7 D) Mounting: Free-standing (standard); wall-mount or pipe-mount (optional) Approximate Weight (without sample system): 80 kg (175 lbs.) Area Safety Certification Options: CSA: Class 1, Division 1, Groups B, C, D, T4 USA: Class I, Zone 1, Ex d IIB+H2, T4, Enclosure Type 4 Canada: Class I, Zone 1, Ex d IIB+H2, T4, Enclosure Type 4 ATEX: Ex II 2G Ex d IIC T4 Tamb = 60 C IECEx: Ex d IIC T4 Gb Tamb = 60 C Oven: Airless heat sink, maximum 130 C (266 F) Valves: 6-port and 10-port diaphragm chromatograph valves. Other types of valves may be used, such as liquid injection or rotary valves, depending on the application Carrier Gas: Application-dependent. Typically zero-grade helium, nitrogen, or hydrogen Sample Input Pressure Range (recommended): psig Carrier Gas Input Pressure Range (recommended): psig Detector: Thermal conductivity detector (TCD), flame ionization detector (FID), TCD/TCD or TCD/FID dual detector configurations possible; flame photometric detector (FPD) available (see FPD module data sheet) Gating Options: Fixed-time automatic slope sense gating of peaks Streams: Up to eight streams (including calibration stream) internally controlled; up to 12 streams externally controlled Chromatograms stored/archived internally: Most recent analysis and/or calibration per stream Analog Inputs: Four inputs filtered with transient protection (user scalable and assignable) Analog Outputs: Four non-isolated analog outputs, 4 20 ma (standard); four additional isolated analog outputs or eight additional non-isolated analog outputs (optional) Serial Communication Ports: Three serial ports standard with option for a total of seven. Depending on the port, choice of RS-232, RS-422, and RS-485 is available as well as the Modbus protocol Digital Inputs: Five digital inputs; user assignable Digital Outputs: One gas chromatograph alarm and four user-assignable outputs (2 form A, 3 solid-state optically isolated) Parallel Printer Port: One parallel port available for printed reports Internal Modem (optional): Field-configurable; 300 to 33.6k baud rate Ethernet Card (optional): 10 mbps with RJ-45 port RAM (DATA) Memory Capacity: 128 Mb RAM (standard) Outline and Mounting Details OR 2 POLE MOUNT OPTION X Ø.50 THRU REMOVAL CLEARANCE TYPICAL SAMPLE PLATE SAMPLE PLATE RECOMMENDED FROM GROUND OR FLOOR FRONT VIEW FLOOR MOUNT UNIT SIDE VIEW FLOOR MOUNT UNIT FRONT VIEW WALL MOUNT UNIT POLE MOUNT UNIT Page 11
12 Notes: Emerson Process Management Daniel Measurement and Control, Inc. World Area Headquarters Houston, Texas, USA T: , F: USA Toll Free GC-CENTER Calgary, Alberta, Canada, T: , F: Singapore - Asia Pacific, T: , F: Stirling, Scotland - Europe, Mid-East, Africa, T: , F: Daniel Measurement and Control, Inc. and Rosemount Analytical are a wholly owned subsidiaries of Emerson Electric Co., and are divisions of Emerson Process Management. The Daniel name and logo are registered trademarks of Daniel Industries, Inc. The Emerson logo is a registered trademark and service mark of Emerson Electric Co. All other trademarks are the property of their respective companies. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by Daniel s terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time. Daniel does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Daniel product remains solely with the purchaser and end-user. Daniel products are protected by United States and international patents and patents pending Daniel Measurement & Control, Inc. All rights reserved. Unauthorized duplication in whole or in part is prohibited. Printed in the USA. Page 12 May 2010
Danalyzer Model 700 Gas Chromatograph
Danalyzer Model 700 Gas Chromatograph Page 1 www.daniel.com Danalyzer Model 700 Gas Chromatograph Danalyzer Model 700 Gas Chromatographs offer the broadest range of analysis options available today in
Emerson Gas Chromatograph Solutions For Natural Gas Transmission Applications. Superior Performance, Repeatability, and Reliability
Emerson Gas Chromatograph Solutions For Natural Gas Transmission Applications Superior Performance, Repeatability, and Reliability Struggling to Reduce Costs While Meeting Tighter Energy Measuremen What
Rosemount Analytical 1500XA Process Gas Chromatograph
NGC_PDS_1500XA Product Data Sheet Rosemount Analytical 1500XA Process Gas Chromatograph Emerson Process Management offers a complete line of gas chromatographs specifically designed for process applications.
Natural Gas Processing Solutions Using the 700XA Gas Chromatograph
Application Note Oil & Gas Natural Gas Processing Solutions Using the 700XA Gas Chromatograph Optimizing the efficiency and profitability of a natural gas processing plant requires responding to the changing
Chromatograph Maintenance and Troubleshooting Class # 5050
Chromatograph Maintenance and Troubleshooting Class # 5050 Shane Hale Business Development Manager Emerson Process Management Gas Chromatographs Division 5650 Brittmoore Drive Houston, TX 77041 USA Introduction
Process Instrumentation
Process Instrumentation Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Process Gas Chromatography Features of Process Chromatographs Agilent 7890A
Natural gas chromatograph LNG gas quality testing
Application description AD/2102760-EN Natural gas chromatograph LNG gas quality testing Introduction The portable NGC8206 is a natural gas chromatograph designed for installation in a vehicle or mounted
Process Gas Chromatograph
GC8000 Process Gas Chromatograph Process Gas Chromatograph Bulletin 11B08A01-01E www.yokogawa.com/an/ Solutions Long History of GC Technical Excellence okogawa has a long history of supplying process gas
EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases
Product information EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total hydrocarbons
Fundamentals of Gas Chromatography
Application Note Oil & Gas Fundamentals of Gas Chromatography Figure 1 - The Function Components of a Gas Chromatograph Process Line Sample System Chromatograph Oven GC Controller Probe Sample Return Slip
Micro Motion 3098 Gas Specific Gravity Meter
Product Data Sheet PS-001161, Rev. D April 2013 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.
CHROMOCTANE O N LINE ANALYZER
GECIL Process GT instruments CHROMOCTANE O N LINE ANALYZER ASTM D6733 DHA and RON and MON on line GC for Reformer unit Automatic Chromatographic system for analysis of naphta feeds and reforming gasolines
Rosemount Analytical s X-STREAM XE Web-Browser Interface Takes Process Analysis to the Next Level
Solutions for the Process Industries Rosemount Analytical s -STREAM E Web-Browser Interface Takes Process Analysis to the Next Level The -Stream E takes process gas analysis to the level of ease of use
Microcor Wireless Transmitter (MWT)
Rohrback Cosasco Systems, Inc. Microcor Wireless Transmitter (MWT) Features: Highly Secure and Reliable Self Organizing Wireless Mesh Network High Resolution Metal Loss Measurement for all process environments
S-series SQ Controller
DeltaV Distributed Control System Product Data Sheet December 2015 S-series SQ Controller Scalable controllers Quick assembly Easy-to-use Field proven architecture Designed for Electonic Marshalling Advanced
Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward
Chemical Analysis Natural Gas Analyzer A Family of optimized GC Solutions think forward Gas Chromatography Bruker Natural Gas Analyzers Natural gas is bought and sold as a bulk commodity with price based
Process gas chromatographs. Measurement made easy. Compliance Solutions for 40CFR60 Subpart Ja
Process gas chromatographs. Measurement made easy Compliance Solutions for 40CFR60 Subpart Ja Introduction ABB offers a proven analytical solution to completely meet your Refinery Flare Monitoring requirements
The DL8000 Preset Controller. The Ideal Device for Controlling and Measuring the Loading of Liquid Hydrocarbons into Transporting Tankers
The DL8000 Preset Controller The Ideal Device for Controlling and Measuring the Loading of Liquid Hydrocarbons into Transporting Tankers Reliability, ruggedness, flexibility, and accuracy all in one package
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Emerson Smart Firewall
DeltaV TM Distributed Control System Product Data Sheet Emerson Smart Firewall The Emerson Smart Firewall protects the DeltaV system with an easy to use perimeter defense solution. Purpose built for easy
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional
On-line Dissolved Gas Analysis
On-line Dissolved Gas Analysis accord. to IEC 567/ASTM 3612 Online-Monitoring of transformers Automatic on-line analysis of 11 gases The analysis is done in 2 steps with high selectivity and accuracy fully
S-series Mass Connection Solutions
DeltaV Distributed Control System Product Data Sheet March 2015 S-series Mass Connection Solutions Fast, easy and error-free cabinet wiring Modular design, improves reliability Lowers overall termination
IFC 070 Technical Datasheet
IFC 070 Technical Datasheet Electromagnetic signal converter Battery driven with low energy consumption Quick and easy to install and operate External data logger and GSM module for remote data transfer
M-series Virtual I/O Module 2
DeltaV Distributed Control System Product Data Sheet M-series Virtual I/O Module 2 Non-intrusive DeltaV I/O simulation Powerful integration solution Easy to use Modular, flexible packaging The M-series
Bristol ControlWave Redundant Control
October 19, 2007 - Page 1 Bristol ControlWave Redundant Control Redundant systems are offered for critical processes and harsh applications that require maximum operational readiness and system availability.
M-series FOUNDATION Fieldbus I/O
April 2013 Page 1 M-series FOUNDATION Fieldbus I/O Use DeltaV state-of-the-art FOUNDATION Fieldbus redundant I/O for your process control system Increases input/output Takes advantage of all smart device
Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters
Data Sheet Brooks Digital MFC's & MFM's Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters GENERAL FEATURES Wide FS flow range for measurement
3500/93 System Display
3500/93 System Display Bently Nevada* Asset Condition Monitoring Description The 3500/93 System Display is designed to meet the requirements of American Petroleum Institute (API) Standard 670 and provide
TrueAlarm Fire Alarm Systems
TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Fire Alarm System Accessories, 4190 Series PC Annunciator with Multi-Client Capability Features Fire alarm control
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
Analytical Service Certification Program
Analytical Service Certification Program for Service Experts, Representatives and Local Business Partners Visualize > Analyze > Optimize Complete Service. One Source. Rosemount Analytical is offering a
COMBIMASS. Technical Data COMBIMASS eco-bio +
COMBIMASS Technical Data THE SYSTEM COMBIMASS The field transmitters of the COMBIMASS eco series are suitable for gas flow measurement and cover a wide range of different applications. The instruments
Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen
Equipment, facilities, and service networks for data collection/logging, data transfer via e-mail/website, and system streamlining can be established without special knowledge. Energy saving system in
FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)
FLARE MONITORS Infrared Sensors for Monitoring Smokeless Flares, Pilots, and Flame Intensity FMDS2014 FLARE MONITOR (FM) Monitor smokeless flare combustion efficiency to maximize destruction of hazardous
Section 16935 TELEPHONE AUTOMATIC DIALER SYSTEM
Section TELEPHONE AUTOMATIC DIALER SYSTEM PART 1 GENERAL 1.01 SYSTEM DESCRIPTION A. Design Requirements: 1. Electronic monitoring system shall interface plant alarms to public telephone system or cellular
ROC800L Liquid Application Software
ROC800:SW1 Product Data Sheet D301576X012 January 2015 ROC800L Liquid Application Software The ROC800L Liquid Application Software Suite enables the ROC800 platform to perform API compliant liquid flow
Chassis, Power Supply, and Element Management
Chassis, Power Supply, and Element Management C-COR CHP Max5000 Converged Headend Platform Accelerate deployment of new, revenue generating advanced services Innovative technology creating converged high-
M-series MD Plus Controller
August 2013 Page 1 The DeltaV MD Plus Controller and the DeltaV I/O subsystem make rapid installation easy. Increases productivity Easy to use Has the flexibility to meet your needs Introduction The MD
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject
Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION
M A N U A L M E L - T E M P THE LOWEST COST MELTING POINT APPARATUS FOUND ANYWHERE! Low cost unit Temperature range to 500 C Aluminum casting conducts and radiates heat uniformly to capillaries and thermometer.
Daniel Venturi Tubes and Flow Nozzles Brochure
Daniel Venturi Tubes and Flow Nozzles Brochure Is unaccounted hydrocarbon draining your bottom line? When the stakes are high, any amount of unaccounted hydrocarbon drains the bottom line. That's why companies
How To Use Safety System Software (S3)
SPECIFICATION DATA Safety System Software (S3) APPLICATION Safety System Software (S 3 ) is a robust, full featured configuration, diagnostic, programming and real-time monitoring package for integrators
Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000
IMR 5000 Continuous Flue Gas Monitoring System The IMR 5000 is state-of-the-art continuous flue-gas monitoring system, and is designed for a wide variety of flue-gas monitoring applications. The IMR 5000
1500XA Gas Chromatograph
1500XA Gas Chromatograph Hardware Reference Manual 2-3-9000-757, Rev E September 2014 Applies to the Rosemount Analytical 1500XA Gas Chromatograph NOTICE ROSEMOUNT ANALYTICAL, INC. ( SELLER ) SHALL NOT
Model 500 Gas Chromatograph Hardware Reference Manual
Model 500 Gas Chromatograph Hardware Reference Manual Applies to Both Daniel Danalyzer Model 500 Rosemount Analytical Model 500 Part Number 3-9000-537 Revision K JULY 2010 Model 500 Gas Chromatograph
BTU ANALYSIS USING A GAS CHROMATOGRAPH
BTU ANALYSIS USING A GAS CHROMATOGRAPH By Joseph E. Landes Southern Petroleum Laboratories, Inc. Technical Director Hydrocarbon and Field Services 8820 Interchange Drive Houston, Texas 77054 Introduction
Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling
Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,
Uninterruptible Power Supply
96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features
G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method
G4 ICARUS HF Simultaneous Determination of Carbon and Sulfur in Solids Innovation with Integrity Combustion Method High Performance Carbon & Sulfur Analyzer Combustion Method with High-Frequency Furnace
DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS
DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS 1. Description and Phone Number Dialing: The dialer shall be a solid state component capable of dialing up to 16 telephone numbers, each up to 60 digits
KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data
KACO-monitoring watchdog insight prolog Integrated monitoring available Monitor up to 32 inverters per prolog Reliable and accurate data Email alarms to maximize uptime Historical, current and production
HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB
Product datasheet Characteristics HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB Main Range of product Product or component type Display colour Display size Supply Magelis
Centro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
AXIS 262+ Network Video Recorder
31433/EN/R4/0803 Complete Network Video Recording Solution Complete Network Video Recording Solution Picture this: A simple and reliable, plug-and-play video surveillance system for hotels, shops, banks,
LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS WWW.LANCOM4.COM
PORTABLE FLUE GAS MONITORING WWW.LANCOM4.COM i CO low CO high O 2 NO NO2 NOx CO2 H2S SO2 CxHy QUALITY CUSTOMER SOLUTIONS AMETEK LAND HAS BEEN BUILDING PRECISION MEASURING EQUIPMENT SINCE 1947. WE ARE SPECIALISTS
Metering for today s systems
Metering for today s systems The sub-meter gathers data on the building side of the utility company meter. This allows us to break out usage so data can be collected from individual circuits, a single
Regards from the Team at Rheology Solutions.
Rheology Solutions is the sole Australian distributor of this product range and we welcome the opportunity of discussing your application requirements. We hope the information you are seeking is contained
Rackmount Intelligent Pressure Scanners
Rackmount Intelligent Pressure Scanners NetScanner System 9816/98RK-1 FEATURES ±0.05% Accuracy 100 Hz EU Throughput Autonegotiating 10/100/1G Base T Ethernet - TCP and UDP Protocol Pressure Ranges up to
NETWORK ENABLED EQUIPMENT MONITOR
NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone
KNC Model 3666 Automatic Pressure Calibration System
KNC Model 3666 Automatic Pressure Calibration System Product Description The Model 3666 Automatic Pressure Calibration (APC) System by King Nutronics Corporation is a portable secondary standards laboratory
AMS ValveLink SNAP-ON Application
AMS Suite: Intelligent Device Manager Product Data Sheet AMS ValveLink SNAP-ON Application Communicate with both HART and Foundation fieldbus FIELDVUE digital valve controllers in the same application.
O C M III. Open Channel Flow Monitor
O C M III Open Channel Flow Monitor Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic flow transmitter with sensor and temperature compensation probe. B. Under this
MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments
MCP 100 MCP 150 Modular Compact Polarimeters ::: Superior Optical Instruments Your Promise Anton Paar's Solution You have always made sure that your optically active substances meet all quality standards.
PIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions
Lightweight, compact, ergonomic, safe POLARIS FID Portable TOC Analyser for Stack Emissions The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe POLARIS FID" analyser realized by
Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.
GE Measurement & Control Solutions Sentinel LCT Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement Benefits Extremely reliable and highly accurate flowmeter, designed specifically
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
1.44 kw Programmable DC Power Supplies XLN Series
Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable
Lockout Specification BW Clip Maintenance-free single gas detector
Lockout Specification BW Clip Maintenance-free single gas detector The gas detector must satisfy the following. Physical Specifications Size (d x w x h ) Physical detector size shall be no larger than
Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com
Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer
The L&J Engineering Model MCG 1500SFI Servo Gauge
PRODUCT DATA SHEET The is the most compact and lightest servo available today. Accuracy / repeatability of 1/32 inch (0.8mm) Product and Interface, custody transfer Wireless Infrared Calibration Advanced
RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP
RouteFinder SOHO SOHO Security Appliance EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP Quick Start Guide RouteFinder RF825 Series Quick Start Guide RouteFinder SOHO Security Appliance
23 The Thermal Conductivity Detector
23 The Thermal Conductivity Detector General Information TCD pneumatics Conditions that prevent the detector from operating Filament passivation Carrier, reference, and makeup gas Negative polarity Analyzing
User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
DeltaV Remote Client. DeltaV Remote Client. Introduction. DeltaV Product Data Sheet. Remote engineering and operator consoles
January 2013 Page 1 DeltaV Remote Client Remote engineering and operator consoles View Multiple DeltaV Systems from a single workstation Remote Operator Station over low speed and dial up communications
Online Infrared Flue Gas Analyzer Gasboard 3000
Online Infrared Flue Gas Analyzer Gasboard 3000 O 2 CO CO2 SO 2 NO NO x Use of measurement methods Proprietary Infrared NDIR Detectors - Micro-flow in ppm range: CO, NO, SO2, CO2 - Dual beam in % volume
Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)
Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) VPS 504 S06 (120 VAC) is: CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter R-15 (Canada) UL
USB-500/600 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.
Application of the Orifice Meter for Accurate Gas Flow Measurement page 1 DANIEL MEASUREMENT AND CONTROL WHITE PAPER Application of the Orifice Meter for Accurate Gas Flow Measurement www.daniel.com Summary
PROCESS AUTOMATION. OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS PRODUCT OVERVIEW
PROCESS AUTOMATION OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS Industrial Monitors And HMI Solutions PRODUCT OPERATING AND MONITORING wherever you want The Pepperl+Fuchs HMI
USB-500 Series Stand-Alone, Low-Cost Data Loggers
Stand-Alone, Low-Cost Data Loggers Features Stand-alone, remote data loggers Measure temperature, humidity, voltage, or current 1 or 2 channels Low cost, small size Battery powered Software Included, easy-to-use
Tank Gauging & Inventory Management Solutions
& Inventory Management Solutions Automation solutions for oil & gas, defense and aviation applications FuelsManager, Varec s industry-leading software is available in four editions: Standard, Professional,
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
Quick Start Guide 00825-0100-4764, Rev DA March 2014. Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator
Quick Start Guide 00825-0100-4764, Rev DA Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator Quick Start Guide NOTICE This document provides basic guidelines for the Rosemount 8714D. It
LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring
LNG Monitoring Fiber-Optic Leakage Detection System Pipeline leakage detection Regasification and liquefaction monitoring Tank annulus and base slab monitoring Spill containment control Intelligent Solutions
Repeaters and Mimics Data Sheet
Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.
713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.
and Transmitter All-in-one package for open channel flow measurement. 3.1 NEW Class 1, Division 1 Approved Sensor As our products are continuously improved, we reserve the right to make any change in the
A-307. Mobile Data Terminal. Android OS Platform Datasheet
A-307 Mobile Data Terminal Android OS Platform Datasheet Revision 1.1 July, 2013 Introduction A-307 Platform Overview Introduction A-307 Platform Overview The A-307 provides Original Equipment Manufacturers
3500/22M Transient Data Interface
3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and GE s System 1* machinery
FREQUENCY RESPONSE ANALYZERS
FREQUENCY RESPONSE ANALYZERS Dynamic Response Analyzers Servo analyzers When you need to stabilize feedback loops to measure hardware characteristics to measure system response BAFCO, INC. 717 Mearns Road
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
EnerVista TM Viewpoint Monitoring v7.10
EnerVista TM Viewpoint Monitoring v7.10 Guideform Specifications July 7, 2014 Page 1 of 14 1 - Product Overview 1.1 Viewpoint Monitoring Scope EnerVista Viewpoint Monitoring is an easy to setup, powerful
Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem
Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem The Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem (DPC3010) provides DOCSIS broadband service providers with a cost-effective solution for delivering high-speed
30-120 3 Phase Modular Finally the benefits of Modular ups are for all
MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion
Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications
Page 1 / 14 Technical specifications Page 2 / 14 SUMMARY 1. GENERAL OVERVIEW 1.1 MIOS and the remote management 1.2 The MIOSBOX range 1.3 Synthesis of MIOSBOX s specificities 2. DETAILED PRESENTATION OF
Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected
Niagara Security Overview Niagara Security by Tridium, is an open, web-based security management solution that allows you to manage and monitor your facility anytime, anywhere. Built on Tridium s Niagara