1 Specifications for Towers and Civil Works Scope of work: The scope of works includes supply of Towers and miscellaneous items for the Expansion of GSM Rural B-Mobile project. 1 General 1) This Section covers the technical requirement for towers concerned with the following facilities: - Antenna supporting structures and their foundations required 2) Documents and articles necessary for approval by the local approving authorities are as shown in the following table: Sl. No. A B C D E Items Time for Submission Quantity List of materials and Machinery-andtools. Test certificates and Reports Shop drawings and manufacturer s drawings Samples and catalogues Any other documents Before commencement of the Civil Works. Whenever occasion arises Whenever occasion arises Whenever occasion arises Whenever demanded by the Employer / Local approving authorities. Three(3) Three (3) As specified in this document As specified in this document The outline of the aforesaid documents and articles are as follows: a) List of Materials and Machinery-and- tools Main materials and machinery-and-tools to be used for the execution of the Civil Works shall be listed. The list shall state type and model of the materials and the products, name and address of the manufacturers and conformity of the Standards, and may be classified into two parts: items to be purchased locally and from other countries. No procurement shall be allowed before approval of the list. ii) Test Certificates and Reports Test certificates and reports on the tests carried out at factories, laboratories or at the Sites shall be submitted occasionally. Not only the tests specified in this
2 specification but also the tests required by the supplier shall be carried out according to the instructions. iii) Shop Drawings and Manufacturer s Drawings. The drawings specified in this Specification shall be submitted according to the Employer s instructions. The supplier shall submit revised drawings if the Employer so requires. No work shall commence before getting the Employer s approval to the relevant shop and manufacturer s drawings. iv) Samples and Catalogues. Samples and catalogues shall be specified in this specification. iv) Any other Documents. Any other documents specified in this Chapter or the documents directed by the Employer during the progress of the Civil Works shall be submitted. 1.1 Modification of Materials and Methods of Works Except in cases where the modification of design is required by Employer or the approving authorities, the supplier shall strictly comply with the approved Specifications and Drawings. If the contractor requires modification of designs or alteration of materials and methods of works specified in this document, he shall submit the report stating the reasons for the modifications and the details of such modifications clearly, comprehensively and correctly besides submitting samples of modified materials with relevant specifications from the manufacturers. No modified works shall be carried out before getting the Employer s consent. If the bidder feels that the design specified by the employer is inadequate, an alternative design may be proposed at no additional cost to the employer. 2 Design Requirements The Supplier is required to design the towers of 4 Legged with angular construction for 40M & 30M and 3-legged triangular self supporting tubular tower for the height of 20 meter, 25meter & 30meter considering the following factors: 2.1 General The supplier shall establish the design conditions of the antenna supporting structures and all the other related facilities to carry out the structural calculations and prepare the drawings and descriptions Before commencement of the works specified in section above, the supplier shall submit the following information for approval by the Employer: a) The list of standards, which the contractor intends to apply in accordance with this Specification.
3 b) Grade of steel materials to be used including reinforcing bars and their allowable design stress. c) Outline of design criteria for structural calculations based on: a. Wind load and, if derived from wind tunnel test, method and details of test. b. Seismic load where required. c. Dead load. d. Stress analysis for the telecommunication network facilities, and, if electronic computer is used, explanation on the program to be applied. e. Twist, sway and displacement. f. Snow load. g. Stress analysis for reinforced concrete of the foundation. d) Allowable bearing strength of soil and, if required, statement of the soil bearings described in this Specification. e) Typical schematic drawings showing outline of the proposed facilities and structures. f) Problems on legal conditions of each site relating the design and construction work, including aeronautic laws, if any. g) Climatic conditions of each site including items relating to wind load, ice coating load and seismic load. h) Outline of geographical condition of each site i) Detail time schedule of execution of the design. j) Other important items to be determined before structural calculation and preparing drawings and specifications After completion of preparation of the drawings and descriptions, the following information / details shall be submitted in two (2) copies to the Employer for approval: 1 Explanation on Design, including: 2 List of the standards applied. 3 Special legal conditions of each site relating design of the facilities, if any. 4 Climatic conditions of each site including items relating wind load, ice coating load and seismic load. 5 Details of wind tunnel test if carried out. 6 Type, size, dimensions weight, quantity and positions of antennas to be mounted on the antenna supporting structure, including future plan. i) Structural calculations for the facilities structures, showing: ii).calculation of load, viz. dead load, including ice coating load, wind load and seismic load where required.
4 iii). Stress analysis and section designs, including: a. Line diagram showing each member stress corresponding to various loading conditions. b. Tables on load carrying members, listing sizes, lengths, slenderness ratios, allowable stress, actual stress and the sizes and members of bolts at each connection. c. Local stress analysis and section design of the structure at the parts on which the antennas and the appurtenances are to be mounted (including adjacent members affected). d. Maximum twist, sway and displacement of the main supporting structure in the worst loading condition. i) Structural calculations for the foundations, including: Load on the foundation by the facilities structure in the various loading conditions. Calculations of stability against uplift, shearing and down-thrust stresses caused by the load. Calculations for the reinforcement. ii) Drawings, showing: Layout of the foundations and facility s structures station wise, details of the foundations and facility s structures station wise, and position, dimension and type of the antennas to be mounted on the antenna supporting structure Immediately after approval by the Employer, the supplier shall submit three (3) sets of the approved explanation on design, structural calculations, drawings and descriptions The approval of the design conditions, calculations, drawings and descriptions shall not relieve the supplier from his responsibility for the accuracy, adequacy and reliability of the facilities to be constructed Where necessity of change of the approved design conditions, calculations, drawings and / or description arises, these shall be approved by the Employer. 2.2 Structural Design 2.3 General a) Unless otherwise specified, the antenna supporting structure shall be selfsupporting with self supporting type and the foundation shall be of reinforced concrete. b) Any stress of component of facilities, of steel, bolt, reinforcing bar and concrete shall not exceed allowable stress of material specified in the Standard. c) The design for steel structure shall be based on the following concept and assumption incase if the tower structure to be constructed:
5 a. Steel structure shall be regarded as an elastic body. b. Steel structure shall be analyzed as a space framework. However, in common trussed structures, the stress may be calculated as a plane, truss of which the members are frame din one plane, substituting the space framework, and furthermore, where the common truss has small inclination, the truss may be calculated on the projection of the truss on the vertical plane. In this case, the following shall be taken into consideration: i. Where the inclination of the truss is not uniform, interaction between two inclination ii. Other influence caused by construction of the plane trusses as a space framework. c. Neither the stress caused by dead load including ice coating load, nor the stress resulting from the combined load of dead load and wind load or seismic load shall exceed allowable stress of the materials specified in the Standard. d) The stress analysis may be carried out by means of electronic computer subject to applying the proven stress analysis program. e) While designing 3-Legged Self supporting Towers of 20 and 25M a maximum weight for each section member shall not exceed 40Kg/section-leg to ease head load transportation burden to some of difficult sites. While the weight of section member above 25M tower shall not exceed 50kg/section Loads on Facility s Structure a) Dead Load Dead load means the dead weight of the antenna supporting structure and all other facility s structure, all appurtenances and other such items as antennas, which are to be mounted on the main supporting structure. Where required, dead weight of the ice, which is expected to coat on all members of the antenna supporting structure and all other facility s structure, the appurtenances, antenna, etc., shall be included in the dead load. At sites over 2,500 meters above sea level, antenna supporting structures, antennas and all other facilities shall be considered for ice coating load. Unless otherwise specified, radius thickness of the ice coating and density of the ice may be assumed as 10 mm and 0.6 g / cu.cm respectively. b) Wind Load a) Full calculation shall be taken in the wind load acting on the antenna supporting structure and all other facilities, the appurtenance and antenna, etc. to be attached
6 on the main supporting structure. The ice coating, if required, shall be included as a part of the projected area for locations over 2,500 meters above sea level. b) The combined effects of dead load and wind load shall be taken into calculation in the stress analysis so that the worst stress in all component part can be determined. Where height, direction, size and/or type of the antennas are not specified and they cannot be determined at the stage of structural calculation, these shall be so assumed that they cause the worst effects on the structure when wind load is calculated. c) Unless otherwise specified, any formulas, coefficients and factors required for calculation of the wind load shall be in accordance with the standard, or the results of tunnel test as an alternative of the Standard. d) For the purpose of design and calculations, the wind speed shall be taken at 180 Km / hour c) Seismic load i) Where required to consider, the combined effect of dead load and seismic load shall be taken into the calculation. ii) Combined effects of seismic load and wind load may not be taken into the calculation. iii) The lateral seismic factor may be assumed as k = 0.1 from the 100 year probability value of 100 gal given in the maximum expected seismicity distribution map of the world published by the Building Research Institute (Ministry of Construction, Japan) or an equally renowned institute, for the calculation. d) Soil Bearing Capacity Soil bearing capacity at all the sites is assumed as at least 10 tons / sq.m. e) Transmission Loss of Telecommunication Network. Radio transmission loss shall be as follows:- i) Wind speed 90 km/ h (25m/sec) = Radio transmission loss < 3Db. ii) Wind speed 150km/h (42m/sec) = Radio transmission loss <20Db Twist, Sway and Displacement. a) Twist means horizontal angular displacement of the main supporting structure at each antenna mounting elevation from no wind load position to worst wind load position.
7 Sway means vertical angular displacement of the central vertical axis at each antenna mounting elevation from its no wind position to the worst wind load position, divided by each corresponding elevation. b) Unless otherwise specified, twist, sway and displacement shall not exceed the following values: a. Twist : 1 deg. b. Sway : 1 deg. c. Displacement : 1/ Welding Materials The electrodes to be used for welding shall be standard products. Appropriate electrodes shall be selected for the type of steel to be welded. Welding materials other than those stipulated above shall be selected according to the method of welding to be employed Bolt Holes. The diameter of bolt holes shall be larger by 0.5 mm than the diameter of the bolt itself. Anchor bolts shall be secured by using two (2) nuts. For bolts, other than those mentioned above, and for those embedded in concrete proper precaution shall be taken to prevent nut loosening by using either double nuts or spring washers or any other acceptable methods. 2.5 Welding General This clause applies to the arc welding of structural steel elements. a. In-site welding shall be carried out after inspection of the steel fabrication and election. b. The welding shall be done only by qualified and experienced welders. 2.6 Product Inspection a) In-shop inspection report of finished products shall be submitted to the Employer for approval. b) The products shall be inspected by the Employer after the in-shop inspection by the manufacturer.. c) Faulty portions shall be promptly rectified. 3.0 Antenna Support Structure
8 3.1 General 3.2 Tower Shape a) The antenna supporting structure to be constructed shall consist of foundation, main structure, and appurtenances. b) All steel materials including bolts and nuts shall confirm to international standards. All materials of antenna supporting structure including other steel members used in the structure shall be coated by hot-dip galvanizing after all fabrication works has been completed. c) The antenna supporting structures shall be inspected by the Employer during the construction as well as after the completion of the construction works. d) A copy of the final drawings and instructions shall be submitted to the Employer promptly after the completion of the antenna supporting structures for the Employer s record The towers shall be of triangular shaped lattice self supporting towers, made of tubular members designed to cater total load of maximum 250kg( Max.) which shall consist of 3 nos. GSM antennas and 1 no. microwave/radio antenna etc The towers are to be designed for height of 15 meters, 20 meters, 25meters and 30meters for 3-legged self supporting tubular tower Each tower shall equipped with a variety of accessories, such as working plate forms (mesh type), antenna mounts, safety devices, ladders, obstruction lights, lightning protection kit etc, which can be installed at any desired height and orientation. Antenna Mounting Consistent with tower height, towers shall be arranged to support antennas at a number of different levels, 4.0 meters apart, measured vertically. This distance may be altered slightly to fit in with the geometry of the tower bracing. Each antenna mounting position shall be capable of being served by an access platform located approximately 1 meter below the centre-line of the antenna position it serves. Mounting platforms shall be provided for all antenna positions, which are to be utilized by the Bidder in meeting the radio system requirements. Mounting platforms are not required for unequipped antenna mounting positions. Antennas shall be mounted on mounting bars to be attached at each mounting level, at set specified vertical distance apart. This
9 distance shall be specified by the Bidder, but should be typically of the order of 1.5 meters. Three sectored GSM antennas shall be mounted on bars/pipes of 50mm-100mm in diameter and 3000mm in length. In addition, two similar bars/pipes shall be provided below the GSM antenna for mounting the radio antenna. Appropriately sized holes shall be provided in the tower legs at each mounting level for mounting bars to be added as required for future radio systems. Bidders shall allow for 2 pairs of holes per leg on each face at each mounting level. Antenna Feeder Runway Each tower shall be equipped with a straight, vertical antenna feeder runway extending from the ground to the top of each tower for the provision of coaxial cable and wave guide feeders as necessary. This runway shall have provision for future radio system expansion of: 10 cables -16mm Dia. 10 cables/waveguides -28mm Dia. For towers with a central runway, the lower end of the runway shall be set in a concrete foundation laid on a solid base. Typically this would consist of a concrete foundation block approximately 1.0m x 0.4m deep. The Bidder shall include design details for a suitable sized antenna feeder gantry extending from the tower structure to the equipment building. This gantry shall be of sturdy construction utilizing galvanized steel members and offer some protection to the feeder cables in the event of flying debris in high winds. Feeder cables should preferably be laid on the underside of the gantry. Platforms Working platforms shall be provided to allow access to each antenna equipped for the initial installation specified in these bidding documents. In addition rest platforms shall be provided on all towers where the vertical spacing between working platforms, or the lowest working platform and ground level, exceeds 15 meters. Rest platforms, where practicable, shall be provided at levels, which coincide with the levels of the working platform for antenna mounting positions.
10 Platform decking shall be of expanded metal mesh, or similar construction, and shall be adequately supported on steel members of appropriate size. Guard Rails Platforms shall be provided with handrails at a height of approximately 1 meter above the decking, intermediate rails at approximately 0.5 meter above the decking and kick rails at the decking level. All rails shall consist of suitably sized rolled steel angle section. Guardrails shall be provided on all platforms and shall be continuous around the outside perimeter and the runway opening of each platform and shall encompass the ladder and ladder guard so that free access to the ladder may be gained from the platforms. Handrails on platforms shall not be structural members and shall be removable to facilitate the mounting of antennas. Ladders Steel ladders with ladder guards shall be provided from ground level to the highest working platform on each tower. The ladder guard shall be so arranged that at each antenna mounting level, a section may be removed to provide access to the further platform without having cut to the vertical strips. Ladder shall, where practicable, continue fpor a distance of atleast 0ne meter above the upper surface of the platform that is served. The stainless shall not, however,, project above the top of a tower. Ladders, ladders guards and ladders support shall not infringe on the space reserved for antenna feeders. Ladders shall be adequately supported to resist lateral movement. Lightning Protection Two lightning discharge rods of height approximately 2.4 meters shall be securely fixed to the top of each tower on diagonally opposite corners. Each rod shall consist of a steel tube with four 13mm diameter rods of length 0.5 meter (approximately) welded to the top of the tube, disposed equally around the tube and splayed upwards at 45 degrees. No separate earth conductor need be provided from the discharge rods to ground and it is necessary, therefore, that all bolted connections in the tower should be free from paint and
11 reasonably clean at the time of assembly. This applies particularly to the point of attachment of the discharge rods to the top of the tower. Earthing An earthing system, generally to the provisions of internationally accepted standard shall be provided at each tower. This shall consist of at least one radial earth strap extending from each tower leg, one loop encircling the tower and a separate loop encircling the equipment building. Particular attention shall be paid to the bonding of earthing straps to tower, runway, gantry and building steelwork. Earthing strap shall consist of pure copper of nominal dimensions 3cm x 2.5 cm. The completed earth system shall have a resistance of less than 2 ohms, when measured with a specific earth resistance-measuring instrument Trial Erection Where deemed necessary by the Contractor or indicated by the Employer, the members fabricated shall be erected on trial basis in the factory at the contractor s cost before transportation in order to confirm accuracy and other requirements of the fabrication Complete Tower Each erected tower, under conditions of negligible wind, shall not deviate from the vertical position by more than one-eighth of one percent of its height Each erected tower, under conditions of negligible wind, shall be straight within 25mm of the nominal geometric position Each erected tower shall be free of inherent twist Where bolts are placed in a generally vertical position, the bolt heads shall be uppermost Lighting Where tower lighting is required the tower shall be equipped with suitable air navigation warning lighting Two 100 watt weather-proof incandescent globes shall be installed at the tower top.
12 3.5.3 Operation shall be from 220 volt AC supply and all power conduits shall be of galvanized iron construction. PVC or other plastic conduit is not acceptable. Additional Information: The weight and base details shall be as under: Tower Ht. Base Size (Approx) for 4 legged angular tower Weight for 4- legged tower Base size for 3- legged tubular tower 40M 4500mm 9800KG 4862mm 6600KG 30M 3500mm 7200KG 3874mm 4600KG 25M 3000mm 6000 KG 3500mm 4200KG 20M 2550 mm 4300KG 2800mm 3900KG Superstructure: Tower has a tapering structure except for the top 7.5m. Weight for 3 legged tubular tower *Note: Weight of tower is inclusive of all parts of Superstructure (including the weight of MW/GSM antennas mounting arrangement i.e. antenna fixtures, Horizontal cable Tray (6 m) along with foundation Bolts &Templates) and must not be less than the weights mentioned above. The bidder must adhere to following Specification in order to qualify for the supply of Tower: Material specification: MS angles of grade A as Per IS: 2062 (1999) with latest amendment and IS: 808(1989) shall he used. All MS angles are to be hot dip galvanized as per IS: 4759(1996), Standard zinc for galvanizing should conform to IS: (1991) or 1S:209(1992). Gusset /Splice Plates: MS of grade A is per IS: 2062 (1999) with latest amendments and all the plates are hot dip galvanized as per IS: 4759(1996). Standard zinc for galvanizing should conform to IS: (1991) or 1S:209(1992). Nuts, Bolts & Washers: Nuts & Bolts of grade 5.6 as per IS 6639(1972)/ IS 1364, IS: 1367 part8 (1992), and Plain washers as per IS 6610 (1972) & spring washers Type B as per IS 3063:1994 shall be used. ELIGIBILITY CRITERIA FOR TOWER TENDER 1 Bidder should be registered manufacturer of Telecom Towers or authorized agent of OEM. In addition to this Bidder must have Supplied towers to at least two countries besides the country of origin. 2. OEM can submit one bid only, either directly or through any authorized supplier. Manufacturer authorization certificate to be enclosed with the bid in case of authorized agent is submitting the bid. 3. Infrastructure approval from any PSU/Govt undertaking. Certificate to be enclosed at the time of Bidding. 4. The Manufacturer should have its own Galvanizing plant of size sufficient to galvanize in house, all tower members. 5. Bidder should have ISO 9001:2008, ISO 14001:2004, & OHSAS 18001:2007 accreditation.
13 6. Average Annual Financial Turnover of the bidder during the last 3 years, ending March 2011 should be at least Rs.5 Crores. 7. Experience of successfully executing 5 orders of similar work for Govt/PSU of valuing not less than Rs 60 Lakh each during the last 4 years ending Dec Similar work includes supply, execution, Testing and Commissioning of Telecom Towers. Completion Certificate from Govt/PSU to be enclosed with the Bid. 8. The bidder must have the experience of execution of at least 3 orders for SITC of towers in hilly terrain.
Residential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
SECTION 22 LIGHTNING PROTECTION SYSTEM
SECTION 22 LIGHTNING PROTECTION SYSTEM 22.01 SCOPE: A. These Specifications shall form a part of the Contract Documents and shall govern construction work for all buildings to be built or modified for
Specifications for Lightning Protection. ASAE Engineering Practice
Chapter 8: Lightning Specifications for Lightning Protection ASAE safety standards are not laws. They are recommended voluntary standards used by designers, engineers, manufacturers and users of the equipment,
TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR
TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR 1.1.0 SCOPE : This specification covers design, manufacture, testing at manufacture s works before
POST AND FRAME STRUCTURES (Pole Barns)
POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 62305-3 Edition 2.0 2010-12 colour inside Protection against lightning Part 3: Physical damage to structures and life hazard INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE
Sports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049
Sports and High Mast Lighting Poles 4 High Mast Lighting Poles General American LitePole offers a raising and lowering system that allows for ease of maintaining the lighting system at ground level. Ideal
MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE
MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE This specification is intended to describe the general requirements applicable to a proper structural mezzanine design. In addition, it is to serve as
INSTALLATION. General. Important Note. Design. Transport
General The roof trusses you are about to install have been manufactured to precise engineering standards. To ensure that the trusses perform as designed, it is essential that they be handled, erected
SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS
July 14, 2015 1.0 GENERAL BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS This work shall consist of furnishing all materials, equipment, labor, and incidentals necessary for conducting bi-directional
Scope of EN 1090-1 Clarification Document
Scope of EN 1090-1 Clarification Document This document has been submitted to the European Commission as the UK view on the scope of EN 1090-1. After discussions, including with the European Technical
Detailing of Reinforcment in Concrete Structures
Chapter 8 Detailing of Reinforcment in Concrete Structures 8.1 Scope Provisions of Sec. 8.1 and 8.2 of Chapter 8 shall apply for detailing of reinforcement in reinforced concrete members, in general. For
Dock Hardware & Accessory Products Catalog
Dock Hardware & Accessory Products Catalog Product Page # Product Page # Angle Brackets/Clips 8 Back Up Plate 5 Backing Plate/Hurricane Stop 10 Carriage Bolt Sets 4 Chain Retainer 10 Connector Pin Set
PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE
FORM A PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE The following suggested specifications are written as a guide to assist the specifier in writing his own specifications. Specific circumstances
TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE
TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE TECHNICAL SPECIFICATION PART 8000 - PRECAST CONCRETE TABLE OF CONTENTS Item Number Page 8100 PRECAST CONCRETE CONSTRUCTION - GENERAL 8-3 8101 General
SECTION 15410 GROUND WATER STORAGE TANKS
SECTION 15410 GROUND WATER STORAGE TANKS PART 1 GENERAL.01 SCOPE A. Section Includes Requirements for designing, fabricating, and erecting a welded steel ground storage tank..02 SYSTEM DESCRIPTION A. Design
SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
SPECIFICATIONS FOR TENDER NO: PSNR/SCP/VKS/E 1635 ANNEXURE I TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST
TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST ANNEXURE I Sl.No. Description for BHEL Requirement Offered Deviation Scope of supply, erection and commissioning: 1 The scope of this specification covers
HANDRAIL STANDARDS HANDRAILS AXESS LADDER SYSTEM KICK FLAT SYSTEM OPEN FLOORING
ENGINEERING LTD. HANDRAIL STANDARDS HANDRAILS AXESS LADDER SYSTEM KICK FLAT SYSTEM OPEN FLOORING Member of PF Group Guardrail Engineering Limited Manders Industrial Estate Old Heath Road Wolverhampton
SECTION 11014 WINDOW WASHING SYSTEMS
SECTION 11014 WINDOW WASHING SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes, but is not limited to, design and furnishing portable davits, davit sleeves, dvit bases, four (4) removable outriggers,
AIRPORT SECURITY FENCING. A. American Society for Testing and Materials (ASTM):
SECTION 02832 AIRPORT SECURITY FENCING PART 1-GENERAL 1.1 SUMMARY A. Section includes: Construct airport security chain-link fence and gate at specified areas and conforming lines, grades, details indicated
After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE
86 :: Certificate in Construction Supervision (CIVIL) 12 ROOF 12.1 INTRODUCTION The structure provided to cover the house surface (floor) is known as roof. For different situation and requirement, it is
TARIFF CODE and updates standard
TARIFF CODE and updates standard No HS CODE AHTN CODE PRODUCT DESCRIPTION PRODUCT TYPE STANDARDS IDENTIFIED 7207 Semi finished products of iron or non alloy steel Containing by weight less than 0.25% of
INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS
INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIRECTIONS GENERAL DESCRIPTION:
EARTHING AND BONDING AT SECONDARY SUBSTATIONS
DISTRIBUTION CONSTRUCTION MANUAL SECTION 4 - SUBSTATIONS ISSUE B SEPT 1996 4.4.4 EARTHING AND BONDING AT SECONDARY SUBSTATIONS 1 SCOPE This section of the Distribution Construction Manual lays down the
Lightning Protection Introduction
Lightning Protection Introduction Structural lightning protection design considerations BS 6651 (Protection of structures against lightning) clearly advises strict adherence to the provision of a conventional
For ease of reference the clauses are arranged in 12 sections as follows:-
NASC TERMS The general NASC terms under which members carry out their work are normally set out in their Standard Terms of Trading, often found on the reverse of their quotation form and referred to as
Uncovered Decks & Porches
Uncovered Decks & Porches Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed
High Strain Dynamic Load Testing of Drilled Shafts
Supplemental Technical Specification for High Strain Dynamic Load Testing of Drilled Shafts SCDOT Designation: SC-M-712 (9/15) September 3, 2015 1.0 GENERAL This work shall consist of performing high-strain
1.02 SYSTEM DESCRIPTION
1 OF 7 MODULAR MEZZANINES GUIDE SPECIFICATIONS FOR PART 1 - GENERAL 1.01 RELATED WORK A. SECTION 03 30 00: Cast in Place Concrete (and Concrete Finishing) 1. The area where mezzanine is installed shall
TS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING
TORONTO TRANSPORTATION January 2012 TS 813 GROUNDING AND BONDING TABLE OF CONTENTS 1. DRAWINGS TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET
CHAIN-LINK FENCES BID SPECIFICATIONS DESCRIPTION
CHAIN-LINK FENCES BID SPECIFICATIONS DESCRIPTION 1 This item shall consist of furnishing and erecting Chain-Link fence in accordance with these specifications and the details shown on the plans and in
Timber Decks. Technical Note. March 2007
Timber Decks Technical Note. March 2007 This Technical Note contains general information for residential timber decks and floor frame structures for veranda s, patios etc which are exposed to the weather.
SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.
SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/HTXLPE/2006) MAHARASHTRA STATE ELECTRICITY DISTRIBUTION CO.LTD.
Consultants Handbook
Consultants Handbook CONSULTANTS HANDBOOK Welcome to our Wallis Designers Lightning Protection Handbook. This handbook offers a guide for any designers of the structural Lightning protection system to
UNIVERSAL RAILING, STEEL
RAILINGS Page Universal Railing, steel 108-109 Large Module Railing, steel 110-111 Allround Railing, aluminium 112-113 Module Railing, aluminium 114-115 Standard Type Railing, aluminium 116-117 107 UNIVERSAL
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,
Embedded Parts Introduction - Anchors
In the plant construction or process plants such as chemical, petrochemical, gas or power plants various disciplines are brought into contact and built on each other. Civil, mechanical, electro technical
PivotLoc Ladder Systems
N25 ACCESS AND SAFETY EQUIPMENT SPECIFICATION CLAUSES PivotLoc Ladder Systems To be read with The Main Contract Preliminaries, General Conditions, Sub-Contract Preliminaries. MINIMUM CONTRACTOR STANDARD
SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
0845 0098 980 www.nicholsonsts.com
0845 0098 980 www.nicholsonsts.com ROOFTRAK The IFP is revolutionising the way we fix things to roofs. Technical Director of a leading UK roofing system manufacturer The ROOFTRAK-IFP A revolutionary solution
Amendment to OPSS 415 (Nov 2008) Construction Specification for Pipeline and Utility Installation by Tunnelling
Engineering and Construction Services Division Standard Specifications for Sewers and Watermains TS 415 April 2013 Amendment to OPSS 415 (Nov 2008) Construction Specification for Pipeline and Utility Installation
SERIES NG 1800 STRUCTURAL STEELWORK
MANUAL OF CONTRACT DOCUMENTS FOR HIGHWAY WORKS VOLUME 2 NOTES FOR GUIDANCE ON THE SPECIFICATION FOR HIGHWAY WORKS SERIES NG 1800 STRUCTURAL STEELWORK Contents Clause Title Page NG 1800 (08/14) General
Fall Protection Solutions
P R O V I D I N G S A F E T Y S O L U T I O N S W O R L D W I D E Fall Protection Solutions COLLECTIVE PROTECTION KEEGUARD FREE STANDING GUARD RAIL APPROVED BY CERAM AND APAVE KEE DOME SKYLIGHT FALL PROTECTION
SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS
SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS
CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS 1.0 DESIGN 1.1 Scope of Work 1.1.1 This work shall consist of furnishing Isolation Bearings and installing Isolation Bearing Assemblies at the locations
CEG/GP/1534/257/RFQ27016/ [01] Technical specification for NB 350 CB pipe :
[01] Technical specification for NB 350 CB pipe : Size :- NB 350 Plain End, ID 336 MM, OD 406 mm, Length - 5.3 meters +/- 25 mm Outer shell : Rolled and welded from 5 mm thick carbon steel coil / plates
TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)
TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.) 1. Requirement: Two (02) Nos. DC Type, 3 phase, 3 wire Projection Welding Machine is required for welding of ventilation M.S. / Stainless
UGVCL/SP/591/11KV HT AB CABLE
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
European Technical Assessment ETA-10/0153 of 10/06/2015
ETA-Danmark A/S Göteborg Plads 1 DK-2150 Nordhavn Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet ww.etadanmark.dk Authorised and notified according to Article 29 of the Regulation (EU) No 305/2011 of
METHOD OF STATEMENT FOR STATIC LOADING TEST
Compression Test, METHOD OF STATEMENT FOR STATIC LOADING TEST Tension Test and Lateral Test According to the American Standards ASTM D1143 07, ASTM D3689 07, ASTM D3966 07 and Euro Codes EC7 Table of Contents
Connection Solutions
Connection Solutions DESIGN BUILD SYSTEM Connection Solutions for Cold formed Steel Construction Complies with; AS/NZS 4600:2005 AISI S100:2007 AS/NZ 1397 ASTM A653 DESIGN & BUILD SYSTEM FRAMECAD Construction
CLAMPS CONNECTORS & EQUIPOTENTIAL RING
CLAMPS CONNECTORS & EQUIPOTENTIAL RING March 2015 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar, Kolkata
Layher. Protective Systems. More Possibilities. The Scaffolding System. Layher Keder Roof and Keder Hall Instructions for Assembly and Use
Layher Keder Roof and Keder Hall Instructions for Assembly and Use Quality management certified according to DIN EN ISO 9001:2000 by German TÜV-CERT Protective Systems Layher More Possibilities. The Scaffolding
Fixed Access Ladders. Table of Contents. 1. Legislative Requirements
Fixed Access Ladders Engineering Data Sheet 2-04 Revised: January 1997 Table of Contents 1. Legislative Requirements 2. General 3. Rungs 4. Side Rails 5. Safety Cages 6. Attachment & Anchoring 7. Platforms
Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-...
Installation guide for the SafeLine type anchorage device Tested in compliance with EN 795: 1996 No.: SE-... Version: 09.10.2008 SE 67 Subject to technical alterations! Contents 1. General information
TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks 174.6 FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.
Pages identified with the NMBS Logo as shown above, have been produced by NMBS to assist specifiers and consumers in the application of New Millennium Building Systems Deck products. Pages identified with
SECTION 260536 - CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.
SECTION 260536 - CABLE TRAYS PART 1 - GENERAL SECTION INCLUDES: A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system. B. Cable tray systems are defined to include, but
1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona
for Earthen Material and Straw Bale Structures SECTION 70 - GENERAL "APPENDIX CHAPTER 7 - EARTHEN MATERIAL STRUCTURES 70. Purpose. The purpose of this chapter is to establish minimum standards of safety
Hyperlinks are Inactive
Prepared by: NIB/EOB PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES 05503 Department: Electric T&D Section: T&D Engineering and Technical Support Approved by: G.O. Duru (GOD)
INTER PLANT STANDARD STEEL INDUSTRY
INTER PLANT STANDARD STEEL INDUSTRY CODE OF PRACTICE FOR REVAMPING OF EOT CRANES IPSS:3-02-014-03 IPSS Corresponding IS does not exist 0. FOREWORD 0.1 This Inter Plant Standard has been prepared by the
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
Cable Trays Technical Instructions & Specifications
Cable Trays Technical Instructions & Specifications Products Catalogue Objective and Structure The company s main objective is the supply of quality products, with respect to: practical design increased
Wisconsin Building Products Evaluation
Safety & Buildings Division 201 West Washington Avenue P.O. Box 2658 Madison, WI 53701-2658 Evaluation # 200813-O Wisconsin Building Products Evaluation Material Best Management Standards for Foundation
11 Guardrail. W-Beam Guardrail Pre-Installation Inspection During Installation Basis for Use. Modified Guardrail. End Treatments and Transitions
11 Guardrail W-Beam Guardrail Pre-Installation Inspection During Installation Basis for Use Modified Guardrail End Treatments and Transitions Footings and Anchors Impact Attenuators Measurement and Payment
HIGH TENSION CABLE BARRIER
Special Provision September 11, 2006 SECTION 02845 S HIGH TENSION CABLE BARRIER PART 1 GENERAL 1.1 SECTION INCLUDES A. Cable barrier materials and installation procedures. 1.2 RELATED SECTIONS A. Section
Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS
Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS 1009.1 Stairway width. The width of stairways shall be determined as specified in Section 1005.1, but such width shall not be less than 44
Design and Construction of Cantilevered Reinforced Concrete Structures
Buildings Department Practice Note for Authorized Persons, Registered Structural Engineers and Registered Geotechnical Engineers APP-68 Design and Construction of Cantilevered Reinforced Concrete Structures
4B-2. 2. The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.
Shear Walls Buildings that use shear walls as the lateral force-resisting system can be designed to provide a safe, serviceable, and economical solution for wind and earthquake resistance. Shear walls
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 13 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia ELECTIRAL GROUNDING TABLE OF CONTENT
Handling, Erection and Bracing of Wood Trusses
Handling, Erection and Bracing of Wood Trusses Follow these guidelines for safe installation of Wood Trusses. These guidelines should not be considered to be the only method for erecting and bracing of
BAGGAGE HANDLING SYSTEMS. Trastecnica S.p.A. Handling Baggage Systems Edition 2002 - Rev. 00-1 -
BAGGAGE HANDLING SYSTEMS Trastecnica S.p.A. Handling Baggage Systems Edition 2002 - Rev. 00-1 - TECHNICAL SPECIFICS INDEX Check-in with one conveyor 4 Scales 6 Belt Conveyors 8 Take away 9 Feeder and Belt
CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements
16600 Underground Electrical Duct Bank This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications
Requirements for the Attachment of Communication Cable Facilities on PPL Poles
Page 99 of 137 Requirements for the Attachment of Communication Cable Facilities on Replaces: URS-3002 URS-3004 URS-101C-304 A-157649 Page 100 of 137 Reference Notes for Drawings: General 1. The term communication
Cellar Tech Containment Well Cellar Systems www.cellartech.com
Sealed Well Cellars are protected by US patent 7637692, 7987904, 8127837, and 8256505. Additional US patents pending. Basic Containment Well Cellar Sealed Well Cellars are protected by US patent 7637692,
MAST ARMS & POLES. Ornamental Pole Top & Bases
Ornamental Pole Top & Bases Pelco s decorative pole top and bases help make the traffic signal aesthetically pleasing to the eye. Available for various pole diameters and multiple finish options. Ornamental
SAFETY FENCES, SAFETY BARRIERS AND PEDESTRIAN GUARDRAILS
SERIES NG 400 SAFETY FENCES, SAFETY BARRIERS AND PEDESTRIAN GUARDRAILS Contents Clause Title Page NG 401 Performance Criteria for Safety Fences and Safety Barriers 2 NG 402 Components for Safety Fences
This mount uses concrete parking bumpers and a Davis tripod to create a mounting solution for nonpenetrable
NON-PENETRATING FLAT ROOF MOUNT Application Note 18 For Any Davis Weather Station Installed on a Mounting Tripod Introduction This application note describes various mounting solutions for non-penetrable
60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING
60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed
GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables
Engineering Department SEPTEMBER, 2007 GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables General Requirements This section applies to all public and private utilities,
Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig. 7.21 some of the trusses that are used in steel bridges
7.7 Truss bridges Fig. 7.21 some of the trusses that are used in steel bridges Truss Girders, lattice girders or open web girders are efficient and economical structural systems, since the members experience
SECTION 15140 - PIPE HANGERS AND SUPPORTS
Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the
Awning Instructions. Standard Manual 1.5m to 4.5m
Awning Instructions Standard Manual 1.5m to 4.5m English Standard Manual Instructions Contents Warning 1.5m 3.0m Awnings 4 x Expansion bolts (2 per bracket)** 2 x brackets 1 x Awning 1 x Winder handle
Chapter 6 ROOF-CEILING SYSTEMS
Chapter 6 ROOF-CEILING SYSTEMS Woodframe roof-ceiling systems are the focus of this chapter. Cold-formed steel framing for a roof-ceiling system also is permitted by the IRC but will not be discussed;
Security Cameras, CATV, GPS & Satellite Protection. White Paper
Security Cameras, CATV, GPS & Satellite Protection White Paper Security Cameras, CATV, GPS & Satellite Protection Surge Protection Solutions for PTC 1 Security Cameras, CATV, GPS & Satellite Protection
Post and Beam Construction
Post and Beam Construction A Presentation By the Canadian Wood Council Canadian Conseil Wood canadien Council du bois Early settlers introduced the concept of post and beam construction in North America
MONDOATHENS BASKETBALL SET (Reference PK110)
MONDOATHENS BASKETBALL SET (Reference PK110) DESCRIPTION The MONDOATHENS backstop unit is mainly designed for multi-sports pavilions and installations where the highest-level basketball competitions are
METHOD STATEMENT FOR INSTALLATION OF CABLE TRAY/TRUNKING/LADDER
Page 1 of 6 FOR INSTALLATION OF CABLE TRAY/TRUNKING/LADDER 0 Issued for Review & Comments Rev. Date Description Eng. A.H Prepared by Checked by Approved by Page 2 of 6 REVISION CONTROL SHEET REV. NO. DATE
TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT
TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT 1.1 General 1.1.1 These Special Conditions of Contract supplement the General Instructions.
SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA
SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/ 1 X C-UA- LTXLPE/2006) MAHARASHTRA STATE ELECTRICITY
-1- SPECIFICATIONS 002085 CONE SETTER PLATFORM ATTACHMENT INDEX
-1-002085 CONE SETTER PLATFORM ATTACHMENT INDEX I. GENERAL EQUIPMENT : A. Intent Statement B. Cone Setter Platform II. III. 1. Understructure Frame 2. Mounting Components 3. Paint 4. Basket 5. Labels 6.
PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta
PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE By H P Gupta & D K Gupta DIFFERENT TYPES OF DAMAGES 1.Minor cracks 0.5 to 5 mm wide in load or non-load bearing walls 2.Major
LEGACY REPORT ER-5110. www.icc-es.org. ICC Evaluation Service, Inc. Reissued November 1, 2003. Legacy report on the 1997 Uniform Building Code
LEGACY REPORT Reissued November 1, 2003 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900
SunnyMec 3000 The innovative bi-axial PV tracker Data Sheet
SunnyMec 3000 The innovative bi-axial PV tracker Data Sheet Rel. 00 Gen. 2010 Pagina 1 di 10 TECHNICAL DATA Sunnymec 3000 Installed photovoltaic power ( standard efficiency module 12...14 % ) 2,3 to 3,1
Removable Aluminium posts
Post Solent Sail Shades Ltd 120 Billington Gardens Hedge End Southampton SO30 2RT Tel/Fax: 01489 788243 www.solentsailshades.co.uk Email: [email protected] Removable Aluminium posts Single Pole
Smart Electromagnetic Flowmeter Open channel Flowmeter Detector
Magne3000 PLUS Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Model NNK150/951 OVERVIE The Magne3000 PLUS Electromagnetic Flowmeter is submersible type of flowmeter mainly used for flow
Certification: Building Plans Examiner. Exam ID: B3
Certification: Building Plans Examiner Exam ID: B3 Scope: A Building Plans Examiner will be responsible for reviewing submitted plans to determine if they meet the requirements of the various Building