LOW ENERGY ELECTRON ACCELERATORS APPLICATION
|
|
|
- Ruby Louise Kennedy
- 9 years ago
- Views:
Transcription
1 LOW ENERGY ELECTRON ACCELERATORS APPLICATION V. Shvedunov Skobeltsyn Institute of Nuclear Physics Lomonosov Moscow State University 10 November 2011
2 Electron accelerators in the range MeV Some applications use bremsstrahlung (X-rays) radiation, some electron beam. For X-rays ( x) I = I exp µ 0 For electrons Different mechanisms of radiation interaction with matter are used for different applications - at level of molecules, atoms, nuclei
3 ACCELERATORS
4 Electron accelerators in the range MeV in most cases are built as direct current accelerator with max beam power up to several hundred kw and efficiency 80-90%. Basic suppliers: Nissin High Voltage Ion Beam applications Budker Institute Efremov Institute
5 Examples of electron accelerators in the range MeV ELV (Budker Institute) MeV, up to 500 kw Nissin HV 5 MeV,150 kw
6 Examples of electron accelerators in the range MeV DYNAMITRON (IBA)
7 Electron accelerators in the range 5 10 MeV in most cases are built as RF standing wave or traveling wave linear accelerator (linac) with max beam power up to hundred kw and efficiency 20-30%. Traveling Wave (TW) RF waveguide Standing Wave (SW)
8 CUT VIEW OF STANDING WAVE ACCELERATING STRUCTURES Side coupled On-axis coupled
9 Examples of electron linacs in the range 5 10 MeV TitanBeta SW linac 10 MeV, 25 kw Mitsubishi Heavy Industries TW linac 10 MeV, 25 kw IMPELA SW linac 10 MeV, 50 kw SureBeam SW linac 5 MeV,100 kw
10 Example of electron accelerator in the range 5 10 MeV - recirculating RF cavity accelerator Rhodotron, IBA 5-10 MeV up to 700 kw
11 In some applications cheap betatrons are used in the range 3 25 MeV Betatron principle 10 MeV betatron for IORT (Tomsk) MeV betatrons (Tomsk)
12 Electron accelerators in the range MeV in most cases are also built as RF linear accelerator with max beam power up to tens kw and efficiency 20-30%. In some cases microtrons and betatrons are used. Microtron
13 Examples of electron accelerators in the range MeV MEVEX, Canada, 35 MeV linac for isotopes production Varian 25 MeV Clinac 20 MeV circular microtron, Indore, India
14 Electron accelerators in the range MeV in most cases are built as multisections RF linear accelerator or as race-track microtron (RTM).
15 Examples of electron accelerators in the range MeV Scanditronix medical RTM MM-50 Danfysik 53 MeV RTM Research Instruments 100 MeV linac
16 APPLICATIONS
17 Electron accelerators application for material processing, sterilization, desinsection Chemical and biological effects at molecules level are produces by ~ev energy electrons. Initial high electrons energy is required to penetrate inside the material. Productivity: m t P = η D beam To increase penetration electron energy can be converted to X-rays energy at bremsstrahlung target, but efficiency of conversion in energy range below 10 MeV is below 10%, so high power electron beams are required.
18 Dose requirements for various radiation effects and productivity for 10 kw electron beam power 1 Gy = 1 J/kg Radiation effect Dose requirements Productivity Sprout inhibition (potatoes, onions) Gy ~ tons/hour Insect control (grains, fruits) Gy ~80-40 tons/hour Fungi and mould control 1-3 kgy ~10-3 tons/hour Bacterial spore sterilization kgy ~2-0.7 tons/hour Polymerization of monomers kgy ~2-0.4 tons/hour Anthrax killing kgy ~ kg/hour Modification of polymers kgy ~ kg/hour Degradation of cellulose materials kgy ~ kg/hour Topaz coloring MGy ~ kg/hour
19 Irradiation facility based on Dynamitron (IBA) Rated Voltage Rated beam current 550 kev 70/100/160 ma 800 kev 70/100/160 ma 1 MeV 60/100 ma 1.5 MeV 40/65 ma 2.5 MeV 40 ma 3 MeV 34/50 ma 4.5 MeV 20/34 ma 5 MeV 10/20/34 ma
20 Structure of 10 MeV/25 kw irradiation facility
21 SINP MSU experience in design, construction and application of electron accelerators for radiation technologies
22 SINP MSU 60 KW, 1.2 MEV COMPACT CW LINAC FOR RADIATION TECHNOLOGIES One- Section Two- Sections Beam energy 0.6 MeV 1.2 MeV Beam current 0 to 50 ma 0 to 50 ma Maximum beam power 30 kw 60 kw Length 0.8 m 1.3 m Gun/klystron high voltage 15 kv 15 kv Plug power consumption ~75 kw ~150 kw Electrical efficiency ~40% ~40%
23 SOME CURRENT APPLICATIONS OF 1.2 MEV COMPACT CW LINAC 1. Test of spacecraft elements (solar batteries etc) for radiation effects 2. Source of high dose rate X-rays radiation 3. R&D for radiation technologies Thermo shrinkable polyethylene film dimensions decrease after different doses. Optimal dose 120 kgy. Intensive bremsstrahlung X-rays source (30 Gy/s at average energy 300 kev)
24 SINP MSU COMPACT CW LINEAR ACCELERATOR FOR RADIATION TECHNOLOGIES WITH LOCAL RADIATION SHIELDING CWL-1-25 Under construction. Beam energy 1 MeV Average beam current 25 ma Average beam power 25 kw Operating frequency 2450 MHz Klystron average power 50 kw Wall plug efficiency 30% Beam scanning width 80 cm Accelerator dimensions 470 x 784 x 1375 mm 1) 1)Without output horn and power supply Accelerator is able to provide operation of thermo shrinkable polyethylene film facility with productivity up to tons/year
25 SINP MSU 10 MeV TECHNOLOGICAL LINAC Beam energy 10 MeV Pulsed beam current 430 ma Average beam power 15 kw Operating frequency 2856 MHz Klystron pulsed power 6 MW Klystron average power 25 kw Wall plug efficiency 20% Beam scanning width 80 cm
26 I Energy spectrum, beam image and beam profile I(45)/I(0) E (МэВ) y (mm)
27 SOME CURRENT APPLICATIONS OF 10 MEV LINAC 1. Test of spacecraft elements (solar batteries etc) for radiation effects 2. R&D for radiation technologies Example of possible application gemstones colorization
28 SINP MSU 10 MeV TECHNOLOGICAL LINAC Proposal Pulsed Linear Accelerator PLA-10-15H Pulsed Linear Accelerator PLA-10-15V Beam energy 10 MeV Pulsed beam current 430 ma Average beam power 15 kw Operating frequency 2856 MHz Klystron pulsed power 6 MW Klystron average power 25 kw Wall plug efficiency 20% Beam scanning width 80 cm Accelerator dimensions 470 x 784 x 1375 mm 1) 1) Without output horn and power supply
29 CARGO INSPECTION AND RADIOGRAPHY X-rays produced by electrons at bremsstrahlung target are used in both applications. X-rays are attenuated by inspected object and registered by X-rays detectors or by film. Basic processes responsible for X-rays attenuation
30 Cargo inspection. 40 mln. sea containers per year move in the word.
31 Cargo inspection - goals. 1. Detection of contraband. 2. Detection of fissile and radioactive materials. 3. Detection of explosive and drugs. Different approaches are necessary for each problem, but in all cases electron accelerators are used or can be used.
32 Typical dimensions. Required speed of development: 0.5 m/s
33 Main components of cargo inspection complex
34 Basic companies providing equipment and complexes for cargo inspection are: Varian Medical Systems (USA) Smiths Detection (UK) Nuctech (China) L-3 (USA) Rapiscan (USA) SAIC (USA) AS&E (USA).. Several other companies are working in this direction
35 Single energy bremsstrahlung X-rays do not permit to evaluate atomic number and can produce only gray picture Uranium µ/ρ (cm 2 /g) Iron Nitrogen Co 60 Bremsstrahlung spectrum E (MeV)
36 Dual energy bremsstrahlung X-rays do permit to evaluate atomic number and can produce color picture Uranium µ/ρ (cm 2 /g) Iron Nitrogen Bremsstrahlung spectra E (MeV)
37
38 The most widely used are X-ray sources from Varian Medical Systems. Linatron-Mi is dual energy X-Ray source fed by magnetron
39 Nuctech (China) also produces 6/9 MeV dual energy X-Ray source fed by magnetron
40 Design by SINP MSU team of 3/6 MeV linac with interlaced energies for cargo inspection X-rays head Beam energy 3.5/6 MeV Dose rate at 1 m Gy/min Operating frequency 2856 MHz Pulse repetition frequency Hz Accelerator dimensions 1000x600x900 mm Accelerator weignt 900 kg 1) 1) Including local radiation shielding Control console
41 Energy spectrum in interlaced energies mode Iav (na) E (MeV) Low High Beam spots diameters are well below 2 mm Scale: 1 square= 1 1 mm
42 ACCELERATOR WITH FAST MAGNETIC ENERGY SWITCHING FOR CARGO INSPECTION (PROPOSAL) RTM Parameters Beam energies Operating frequency End magnets field Injection energy Pulsed RF power Repetition rate, max RTM dimensions 1) RTM weight 1) 3.5, 6, 9 MeV 2998 MHz 0.63 T 25 kev <2 MW 1000 Hz 650x200x150 mm <60 kg (1) electron gun, (2) linac, (3), (4) end magnets, (5) fast extraction magnets, (6) extracted beam, (7) RTM focusing lens, (8) beam current monitor, (9) extracted beam quadrupoles, (10) bremsstrahlung target, (11) radiation shielding with collimator.
43 Radiography Film Digital Introscopic system resolution (detector size 2x2 mm) Accelerator energy, MeV Density resolution, % Spatial resolution, mm Penetrability for steel, mm
44 Varian linac for radiography
45 Nuclear reaction based applications Elemental analysis Isotopes production Explosive detection
46 Photonuclear reaction thresholds Eth (MeV) (γ,p) (γ,n) Z Electron beams with energy higher than 10 MeV are necessary to knock out nucleons from nucleus
47 Photoneutron reaction at different nuclei 12 C + γ --> 11 C + n 40 Ca + γ --> 39 Ca + n 208 Pb + γ --> 207 Pb + n
48 Photo activation technique method of elemental analysis using photonuclear reactions.
49 Nuclei level structure is unique fingerprints permitting to detect specific elements in very low quantities Level structure of gold isotope 196 Au. Level with energy kev has half life period 9.6 h. 196 Au can be produced in this isomeric state via photoneutron reaction at stable isotope 197 Au. In this way gold content in ore can be defined with high sensitivity - better than 1 g/ton
50 Photo activation technique
51 Photo activation technique Gamma ray spectrum obtained with Ge detector
52 Accelerators for photo activation technique Electron beam parameters: Beam energy from ~ 10 MeV to ~30 MeV Beam average current from ~100 µa-1 ma Conversion to bremsstrahlung X-rays
53 Isotopes production Most isotopes for medicine are produced now with cyclotrons, proton linacs and with reactors. List of radioactive isotopes used in medicine for treatment and for producing images includes more than 100 nuclei with life time from several years, e.g. 60 Co, to several seconds, e.g. 191m Ir. Photonuclear reactions offer another way for isotope production. Electron accelerator is several times cheaper than cyclotron
54 PET isotopes short living isotopes for positron emission tomography 11 C (20.4 min), 13 N (10.0 min), 15 O (2.0 min), 18 F (109.8 min) can be produced via (γ,n) reaction on target nuclei 12 C, 14 N, 16 O, 19 F Cross section of (γ,n) reaction is lower than cross section of reactions with heavy charged particles obtained with cyclotron. However for photonuclear reactions much more thick target can be used, so total isotope yield can be sufficiently high.
55 Estimations for PET isotopes yields with cyclotron and RTM Isotope Accelerator Reaction Target Saturation Yields 11 C 70/35 MeV RTM 12 C(γ,n) 11 C Graphite -- Diamond 2.6/3.9 Ci /7.1 Ci 11 MeV Cyclotron 14 N(p,α) 11 C N 2 / 0.5-1% O Ci 13 N 70/35 MeV RTM 14 N(γ,n) 13 N Melamine (C 3 H 3 N 3 ) 1.2/1.6 Ci 11 MeV Cyclotron 16 O(p,α) 13 N 5mM Water&Ethanol 100 mci 15 O 70/35 MeV RTM 16 O(γ,n) 15 O Water 3.2/2.5 Ci 11 MeV Cyclotron 15 N(p,n) 15 O N 2 / 2.5% O mci 18 F 70/35 MeV RTM 19 F(γ,n) 18 F Perfluorocarbon or SF 6 gas 2.2/3.0 Ci 11 MeV Cyclotron 18 O(p,n) 18 F H 2 18 O or 18 O Ci Radiochemistry can not be applied for (γ,n) reaction products isotope with the same as target chemical properties is produced. How to extract? For example, use of thin powder and pick-up recoil nuclei with gas stream.
56 99m Tc (the daughter nucleus of 99 Mo) is most used isotope in medical imagine. It is now obtained with nuclear reactor. Can be obtained in 100 Mo(γ,n) 99 Mo reaction. Method was experimentally verified. Production of very pure 123 I was demonstrated with electron accelerators at several centers. Reaction 124 Xe (γ,n) 123 Xe 123 I was used. Electron accelerator for medical isotopes production: Beam energy from ~ 25 MeV to ~40 MeV Beam average current from ~100 µa to ~200 µa Conversion to bremsstrahlung X-rays
57 Explosive detection with photonuclear reactions Original idea of L. Alvarez Tested by Trower W.P., NIM B79 (1993) 589 The most effective method of concealed explosive search till now is odorant method - dogs. However explosive can be detected by detecting its main constituents - nitrogen and oxygen. Anomaly concentration of nitrogen and oxygen in certain proportion means high probability of explosive presence.
58 β decaying radionuclei photoproduced on stable isotopes with abundance >1 % resulting in three or fewer nucleons. Only photonuclear reactions on carbon, nitrogen and oxygen for beam energy below 70 MeV can produce residual nuclei with half life between 10 and 100 ms.
59 Explosive detection with photonuclear reactions Lebedev Institute Max 70 MeV electron accelerator Detector Scanned electron beam Moving object
60 Explosive detection steps 1. Irradiate during 5-10 µs specific portion of object by X-ray radiation generated by electron beam at large (~object dimensions) bremsstrahlung target. 2. Get decay curve within ~ ms by mean of registration of secondary X-rays, produced by positrons, emitted by residual nuclei. 3. Go to the next part of object Irradiation of the same object part with different electron energy can be used to distinguish between C, N and O. For the same goal different secondary X-rays registration threshold energy can be used.
61 Decay curves measured for different substances Melamine Room air
62 Example of explosive detection No explosive Semtex, 125 g
63 Electron accelerator for explosive detection technique: Beam energy from ~25 to ~70 MeV Pulsed current ~20-50 ma Pulse duration ~5-10 µs Pulse repetition rate Hz Conversion to bremsstrahlung X-rays
64 SINP MSU experience in design, construction and application of electron accelerators for activation analysis, isotopes production and explosive detection
65 SINP MSU 70 MeV PULSED RACE TRACK MICROTRON WITH RARE-EARTH PERMANENT MAGNETS Injection energy 48 kev Energy gain 4.8 MeV / orbit Orbits 14 Output energy MeV Output current at 68.3 MeV 10 ma Orbit circumference increase 1λ/orbit Operating frequency 2,856 MHz Klystron power pulsed 6 MW End magnet field induction T RTM dimensions 2.2x1.8x0.9 m 3 Innovations: -large ~1 T rare-earth permanent end magnets - rectangular accelerating structure with RF quadrupole focusing - electron beam phase shifter - rare-earth permanent magnet compact quadrupole triplets - self excitation RF system A 70 Mev racetrack microtron, V.I. Shvedunov, A.N. Ermakov, I.V. Gribov, E.A. Knapp, G.A. Novikov, N.I. Pakhomov, I.V. Shvedunov, V.S. Skachkov, N.P. Sobenin, W.P. Trower and V.R. Yajlijan, Nucl. Instrum. Meth. A550 (2005)39-53
66 Photoactivation technique Gamma rays spectrum from Ge detector after irradiation of 197 Au with bremsstrahlung from 70 MeV RTM
67 55 MeV PULSED RACE TRACK MICROTRON AT SINP MSU WITH EXPLOSIVE DETECTION SYSTEM COLLABORATION WITH LEBEDEV PHYSICAL INSTITUTE Synchrotron radiation from orbits
68 Radiation therapy Use of ionizing radiation to kill tumor cells by destroying DNA via complicated physical, chemical and biological processes. Together with tumor cells normal cells on the way of radiation are also killed. Special tactic of irradiation: irradiation from several sides, using special collimators, intraoperative radiation therapy etc.
69 Cell survival curves Typical cell survival curves for high LET (densely ionizing) radiation and low LET (sparsely ionizing) radiation. LET linear energy transfer
70 Comparison of electrons and X-rays dose-depth dependencies PPD percentage depth dose
71 External X-ray radiation therapy Irradiation by bremsstrahlung radiation produced by 1-25 MeV electron beam at special target.
72 External electron radiation therapy Irradiation by MeV electron beam scattered by foil via special applicator. Scanditronix medical RTM MM-50
73 Stereotactic radiation surgery (SRS) Providing of high dose of X-rays radiation to well localized volume using several radiation sources or single easy movable source. SRS uses dedicated miniature electron accelerator with energy 4-6 MeV, fixed at robotic arm. CyberKnife - based on 6 MeV X-band linac
74 Intraoperative radiation therapy (IORT) Providing of high dose to well localized volume using several radiation sources or single easy movable source. Similar to IORT modern SRS uses dedicated miniature electron accelerator with energy 4-6 MeV, fixed at robotic arm. Betatron Mobetron Novac7 Liac Russia USA Italy Italy
75 UPC-SINP MSU-CIEMAT collaboration for IORT dedicated 12 MeV race-track microtron
76 Conclusion Electron beams in the energy range MeV have wide and growing spectrum of applications. There are three distinctly different kind of commercial activity in this field : -accelerator design and construction; -technology development; -facility construction and technology application. Many labs conduct R&D in accelerator physics and only a few private companies manufacture commercial electron accelerators. New accelerator busyness can be successful only with new ideas in accelerator design and application.
Atomic and Nuclear Physics Laboratory (Physics 4780)
Gamma Ray Spectroscopy Week of September 27, 2010 Atomic and Nuclear Physics Laboratory (Physics 4780) The University of Toledo Instructor: Randy Ellingson Gamma Ray Production: Co 60 60 60 27Co28Ni *
Medical Applications of radiation physics. Riccardo Faccini Universita di Roma La Sapienza
Medical Applications of radiation physics Riccardo Faccini Universita di Roma La Sapienza Outlook Introduction to radiation which one? how does it interact with matter? how is it generated? Diagnostics
Nuclear Physics. Nuclear Physics comprises the study of:
Nuclear Physics Nuclear Physics comprises the study of: The general properties of nuclei The particles contained in the nucleus The interaction between these particles Radioactivity and nuclear reactions
ACCELERATORS AND MEDICAL PHYSICS 2
ACCELERATORS AND MEDICAL PHYSICS 2 Ugo Amaldi University of Milano Bicocca and TERA Foundation EPFL 2-28.10.10 - U. Amaldi 1 The icone of radiation therapy Radiation beam in matter EPFL 2-28.10.10 - U.
Basics of Nuclear Physics and Fission
Basics of Nuclear Physics and Fission A basic background in nuclear physics for those who want to start at the beginning. Some of the terms used in this factsheet can be found in IEER s on-line glossary.
Chemistry 1000 Lecture 2: Nuclear reactions and radiation. Marc R. Roussel
Chemistry 1000 Lecture 2: Nuclear reactions and radiation Marc R. Roussel Nuclear reactions Ordinary chemical reactions do not involve the nuclei, so we can balance these reactions by making sure that
Nuclear Physics and Radioactivity
Nuclear Physics and Radioactivity 1. The number of electrons in an atom of atomic number Z and mass number A is 1) A 2) Z 3) A+Z 4) A-Z 2. The repulsive force between the positively charged protons does
13C NMR Spectroscopy
13 C NMR Spectroscopy Introduction Nuclear magnetic resonance spectroscopy (NMR) is the most powerful tool available for structural determination. A nucleus with an odd number of protons, an odd number
Chapter 5 TREATMENT MACHINES FOR EXTERNAL BEAM RADIOTHERAPY
Chapter 5 TREATMENT MACHINES FOR EXTERNAL BEAM RADIOTHERAPY E.B. PODGORSAK Department of Medical Physics, McGill University Health Centre, Montreal, Quebec, Canada 5.1. INTRODUCTION Since the inception
Main properties of atoms and nucleus
Main properties of atoms and nucleus. Atom Structure.... Structure of Nuclei... 3. Definition of Isotopes... 4. Energy Characteristics of Nuclei... 5. Laws of Radioactive Nuclei Transformation... 3. Atom
1. In the general symbol cleus, which of the three letters. 2. What is the mass number of an alpha particle?
1. In the general symbol cleus, which of the three letters Z A X for a nu represents the atomic number? 2. What is the mass number of an alpha particle? 3. What is the mass number of a beta particle? 4.
Status of Radiation Safety System at
Status of Radiation Safety System at Taiwan Photon Source Joseph C. Liu Radiation and Operation Safety Division National Synchrotron Radiation Research Center, Taiwan NSRRC layout 1.5 GeV, 120m, 400 ma
............... [2] At the time of purchase of a Strontium-90 source, the activity is 3.7 10 6 Bq.
1 Strontium-90 decays with the emission of a β-particle to form Yttrium-90. The reaction is represented by the equation 90 38 The decay constant is 0.025 year 1. 90 39 0 1 Sr Y + e + 0.55 MeV. (a) Suggest,
Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9
Module 9 This module presents information on what X-rays are and how they are produced. Introduction Module 9, Page 2 X-rays are a type of electromagnetic radiation. Other types of electromagnetic radiation
Bert Windhorst Radiopharmaceutical scientist VU University Medical Center Amsterdam
18 F Production Bert Windhorst Radiopharmaceutical scientist VU University Medical Center Amsterdam 1 Outline Cyclotron technique 18 F targetry : Fluoride and Fluorine production 2 Main PET Isotopes 11
Chapter NP-5. Nuclear Physics. Nuclear Reactions TABLE OF CONTENTS INTRODUCTION OBJECTIVES 1.0 NUCLEAR REACTIONS 2.0 NEUTRON INTERACTIONS
Chapter NP-5 Nuclear Physics Nuclear Reactions TABLE OF CONTENTS INTRODUCTION OBJECTIVES 1.0 2.0 NEUTRON INTERACTIONS 2.1 ELASTIC SCATTERING 2.2 INELASTIC SCATTERING 2.3 RADIATIVE CAPTURE 2.4 PARTICLE
Chapter 18: The Structure of the Atom
Chapter 18: The Structure of the Atom 1. For most elements, an atom has A. no neutrons in the nucleus. B. more protons than electrons. C. less neutrons than electrons. D. just as many electrons as protons.
Radiation and the Universe Higher Exam revision questions and answers
Radiation and the Universe Higher Exam revision questions and answers Madeley High School Q.The names of three different processes are given in List A. Where these processes happen is given in List B.
Objectives 404 CHAPTER 9 RADIATION
Objectives Explain the difference between isotopes of the same element. Describe the force that holds nucleons together. Explain the relationship between mass and energy according to Einstein s theory
Industrial Applications of Electron Accelerators
Industrial Applications of Electron Accelerators Marshall R. Cleland Ion Beam Applications IBA Technology Group 151 Heartland Boulevard Edgewood, New York 11717 Presented at the CERN Accelerator School
Chapter 13 Spectroscopy NMR, IR, MS, UV-Vis
Chapter 13 Spectroscopy NMR, IR, MS, UV-Vis Main points of the chapter 1. Hydrogen Nuclear Magnetic Resonance a. Splitting or coupling (what s next to what) b. Chemical shifts (what type is it) c. Integration
Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics
Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics PART I Geiger Tube: Optimal Operating Voltage and Resolving Time Objective: To become acquainted with the operation and characteristics
For convenience, we may consider an atom in two parts: the nucleus and the electrons.
Atomic structure A. Introduction: In 1808, an English scientist called John Dalton proposed an atomic theory based on experimental findings. (1) Elements are made of extremely small particles called atoms.
CHEM 1411 Chapter 5 Homework Answers
1 CHEM 1411 Chapter 5 Homework Answers 1. Which statement regarding the gold foil experiment is false? (a) It was performed by Rutherford and his research group early in the 20 th century. (b) Most of
Radiation therapy involves using many terms you may have never heard before. Below is a list of words you could hear during your treatment.
Dictionary Radiation therapy involves using many terms you may have never heard before. Below is a list of words you could hear during your treatment. Applicator A device used to hold a radioactive source
Radioactivity III: Measurement of Half Life.
PHY 192 Half Life 1 Radioactivity III: Measurement of Half Life. Introduction This experiment will once again use the apparatus of the first experiment, this time to measure radiation intensity as a function
Objectives. PAM1014 Introduction to Radiation Physics. Constituents of Atoms. Atoms. Atoms. Atoms. Basic Atomic Theory
PAM1014 Introduction to Radiation Physics Basic Atomic Theory Objectives Introduce and Molecules The periodic Table Electronic Energy Levels Atomic excitation & de-excitation Ionisation Molecules Constituents
Radiation Strip Thickness Measurement Systems
Radiation Strip Thickness Measurement Systems During the past years we have increased our sales of radiometric Vollmer strip thickness measurement systems, i.e. X-ray or isotope gauges, dramatically. Now,
2 ATOMIC SYSTEMATICS AND NUCLEAR STRUCTURE
2 ATOMIC SYSTEMATICS AND NUCLEAR STRUCTURE In this chapter the principles and systematics of atomic and nuclear physics are summarised briefly, in order to introduce the existence and characteristics of
History of the Atom & Atomic Theory
Chapter 5 History of the Atom & Atomic Theory You re invited to a Thinking Inside the Box Conference Each group should nominate a: o Leader o Writer o Presenter You have 5 minutes to come up with observations
DEMONSTRATION ACCELERATOR DRIVEN COMPLEX FOR EFFECTIVE INCINERATION OF 99 Tc AND 129 I
DEMONSTRATION ACCELERATOR DRIVEN COMPLEX FOR EFFECTIVE INCINERATION OF 99 Tc AND 129 I A.S. Gerasimov, G.V. Kiselev, L.A. Myrtsymova State Scientific Centre of the Russian Federation Institute of Theoretical
Coating Technology: Evaporation Vs Sputtering
Satisloh Italy S.r.l. Coating Technology: Evaporation Vs Sputtering Gianni Monaco, PhD R&D project manager, Satisloh Italy 04.04.2016 V1 The aim of this document is to provide basic technical information
Cyclotron Centre in Poland and 2D thermoluminescence dosimetry
Cyclotron Centre in Poland and 2D thermoluminescence dosimetry Jan Gajewski Institute of Nuclear Physics, Kraków, Poland Department of Radiation Dosimetry Nuclear Physics Institute Academy of Science of
The ithemba LABS Radioactive Beam Project. R A Bark
The ithemba LABS Radioactive Beam Project R A Bark Scientific Committee Local Committee Rob Bark Krish Bharuth-Ram Pete Jones Steve Karataglidis Kobus Lawrie Rudzani Nemutudi Rudolf Nchodu Paul Papka Carlos
1. Orthovoltage vs. megavoltage x-rays. (AL) External beam radiation sources: Orthovoltage radiotherapy: 200-500 kv range
1. Orthovoltage vs. megavoltage x-rays. (AL) External beam radiation sources: Orthovoltage radiotherapy: 200-500 kv range The radiation from orthovoltage units is referred to as x-rays, generated by bombarding
Development of on line monitor detectors used for clinical routine in proton and ion therapy
Development of on line monitor detectors used for clinical routine in proton and ion therapy A. Ansarinejad Torino, february 8 th, 2010 Overview Hadrontherapy CNAO Project Monitor system: Part1:preliminary
Industrial tracers - Finding leaks and blockages
Cancer Treatment Alpha radiation is used to treat various forms of cancer. This process, called unsealed source radiotherapy, involves inserting tiny amounts of radium-226 into cancerous organs. The alpha
Coating Thickness and Composition Analysis by Micro-EDXRF
Application Note: XRF Coating Thickness and Composition Analysis by Micro-EDXRF www.edax.com Coating Thickness and Composition Analysis by Micro-EDXRF Introduction: The use of coatings in the modern manufacturing
Radioactivity & Particles
Radioactivity & Particles Introduction... 2 Atomic structure... 2 How are these particles arranged?... 2 Atomic notation... 4 Isotopes... 4 What is radioactivity?... 5 Types of Radiation: alpha, beta and
KE A = PE MAX 1/2M v 2 = k q1 q2 /R
CHAPTER 13 NUCLEAR STRUCTURE NUCLEAR FORCE The nucleus is help firmly together by the nuclear or strong force, We can estimate the nuclear force by observing that protons residing about 1fm = 10-15m apart
Structure and Properties of Atoms
PS-2.1 Compare the subatomic particles (protons, neutrons, electrons) of an atom with regard to mass, location, and charge, and explain how these particles affect the properties of an atom (including identity,
Production of X-rays and Interactions of X-rays with Matter
Production of X-rays and Interactions of X-rays with Matter Goaz and Pharoah. Pages 11-20. Neill Serman Electrons traveling from the filament ( cathode) to the target (anode) convert a small percentage
Development of Radiation Resistant Quadrupoles Based on High Temperature Superconductors for the Fragment Separator
Development of Radiation Resistant Quadrupoles Based on High Temperature Superconductors for the Fragment Separator R. Gupta and M.Harrison, Brookhaven National Laboratory A. Zeller, Michigan State University
3 Atomic Structure 15
3 Atomic Structure 15 3.1 Atoms You need to be familiar with the terms in italics The diameter of the nucleus is approximately 10-15 m and an atom 10-10 m. All matter consists of atoms. An atom can be
Unit 1 Practice Test. Matching
Unit 1 Practice Test Matching Match each item with the correct statement below. a. proton d. electron b. nucleus e. neutron c. atom 1. the smallest particle of an element that retains the properties of
Atomic Calculations. 2.1 Composition of the Atom. number of protons + number of neutrons = mass number
2.1 Composition of the Atom Atomic Calculations number of protons + number of neutrons = mass number number of neutrons = mass number - number of protons number of protons = number of electrons IF positive
World-first Proton Pencil Beam Scanning System with FDA Clearance
Hitachi Review Vol. 58 (29), No.5 225 World-first Proton Pencil Beam Scanning System with FDA Clearance Completion of Proton Therapy System for MDACC Koji Matsuda Hiroyuki Itami Daishun Chiba Kazuyoshi
INFRARED MONITORING OF 110 GHz GYROTRON WINDOWS AT DIII D
GA A23981 INFRARED MONITORING OF 110 GHz GYROTRON WINDOWS AT DIII D by Y. GORELOV, J. LOHR, R.W. CALLIS, and D. PONCE MAY 2002 DISCLAIMER This report was prepared as an account of work sponsored by an
From lowest energy to highest energy, which of the following correctly orders the different categories of electromagnetic radiation?
From lowest energy to highest energy, which of the following correctly orders the different categories of electromagnetic radiation? From lowest energy to highest energy, which of the following correctly
Atomic Structure: Chapter Problems
Atomic Structure: Chapter Problems Bohr Model Class Work 1. Describe the nuclear model of the atom. 2. Explain the problems with the nuclear model of the atom. 3. According to Niels Bohr, what does n stand
Short overview of TEUFEL-project
Short overview of TEUFEL-project ELAN-meeting may 2004 Frascati (I) Contents Overview of TEUFEL project at Twente Photo cathode research Recent experience Outlook Overview FEL Drive laser Photo cathode
Electrons in Atoms & Periodic Table Chapter 13 & 14 Assignment & Problem Set
Electrons in Atoms & Periodic Table Name Warm-Ups (Show your work for credit) Date 1. Date 2. Date 3. Date 4. Date 5. Date 6. Date 7. Date 8. Electrons in Atoms & Periodic Table 2 Study Guide: Things You
Vacuum Evaporation Recap
Sputtering Vacuum Evaporation Recap Use high temperatures at high vacuum to evaporate (eject) atoms or molecules off a material surface. Use ballistic flow to transport them to a substrate and deposit.
Monday 11 June 2012 Afternoon
Monday 11 June 2012 Afternoon A2 GCE PHYSICS B (ADVANCING PHYSICS) G495 Field and Particle Pictures *G412090612* Candidates answer on the Question Paper. OCR supplied materials: Data, Formulae and Relationships
Seminar 7. Medical application of radioisotopes - radiotherapy
Seminar 7 Medical application of radioisotopes - radiotherapy Radioisotopes in medical diagnosis. Gamma camera. Radionuclide imaging (PET, SPECT). Radiotherapy. Sources of radiation. Treatment planning.
An example: helium isotopes. An example: helium isotopes. Limits to Detection/Measurement. Lecture 14 Measurements II: Mass spectrometry
Limits to Detection/Measurement Ionization is fundamentally a Probabilistic Process Just like radioactive decay So is transmission through the analyzer There is an intrinsic statistical uncertainty Proportional
Lecture 2 Macroscopic Interactions. 22.106 Neutron Interactions and Applications Spring 2010
Lecture 2 Macroscopic Interactions 22.106 Neutron Interactions and Applications Spring 2010 Objectives Macroscopic Interactions Atom Density Mean Free Path Moderation in Bulk Matter Neutron Shielding Effective
Noble Gases. Outline Nobel Gas Elements Radon and Health Chemistry Homework
Radon and Other Noble Gases The elements in the last column of the periodic table are all very stable, mono-atomic gases. Until 1962, they were called inert gases because they did not react with other
SCH 3UI Unit 2 Outline Up to Quiz #1 Atomic Theory and the Periodic Table
Lesson Topics Covered SCH 3UI Unit 2 Outline Up to Quiz #1 Atomic Theory and the Periodic Table 1 Note: History of Atomic Theory progression of understanding of composition of matter; ancient Greeks and
Environmental Health and Safety Radiation Safety. Module 1. Radiation Safety Fundamentals
Environmental Health and Safety Radiation Safety Module 1 Radiation Safety Fundamentals Atomic Structure Atoms are composed of a variety of subatomic particles. The three of interest to Health Physics
A VERSATILE COUNTER FOR CONVERSION MÖSSBAUER SPECTROSCOPY
A VERSATILE COUNTER FOR CONVERSION MÖSSBAUER SPECTROSCOPY I. BIBICU 1, G. NICOLESCU 2, L. CIOLACU 2, L. SERBINA 2 1 National Institute for Materials Physics, Bucharest 77125, Romania, [email protected] 2
Basic Radiation Therapy Terms
Basic Radiation Therapy Terms accelerated radiation: radiation schedule in which the total dose is given over a shorter period of time. (Compare to hyperfractionated radiation.) adjuvant therapy (add-joo-vunt):
Masses in Atomic Units
Nuclear Composition - the forces binding protons and neutrons in the nucleus are much stronger (binding energy of MeV) than the forces binding electrons to the atom (binding energy of ev) - the constituents
Gamma Ray Detection at RIA
Gamma Ray Detection at RIA Summary Report: Physics & Functional Requirements Cyrus Baktash Physics goals Experimental tools: Techniques & Reactions Functional Requirements Physics Questions (Discussed
Mars Atmosphere and Volatile EvolutioN (MAVEN) Mission
Mars Atmosphere and Volatile EvolutioN (MAVEN) Mission MAVEN Science Community Workshop December 2, 2012 Particles and Fields Package Solar Energetic Particle Instrument (SEP) Davin Larson and the SEP
OBJECTIVE OUTLINE PHOTONEUTRON PRODUCTION
NEUTRON SHIELDING DESIGN AND EVALUATIONS Nisy E. Ipe, Ph.D. Consultant, Shielding Design, Dosimetry & Radiation Protection San Carlos, CA, U.S.A. Email: [email protected] http://www.shieldingconsultant.com/
Development and Experimental Performance Evaluation of a Dose-Rate meter for Pulsed Beam.
5 th International Workshop on Radiation Safety at Synchrotron Radiation Sources Development and Experimental Performance Evaluation of a Dose-Rate meter for Pulsed Beam. A. Vascotto 1, K. Casarin 1, S.
X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission
Principles of Imaging Science I (RAD119) X-ray Production & Emission X-ray Production X-rays are produced inside the x-ray tube when high energy projectile electrons from the filament interact with the
The Models of the Atom
The Models of the Atom All life, whether in the form of trees, whales, mushrooms, bacteria or amoebas, consists of cells. Similarly, all matter, whether in the form of aspirin, gold, vitamins, air or minerals,
Physics 1104 Midterm 2 Review: Solutions
Physics 114 Midterm 2 Review: Solutions These review sheets cover only selected topics from the chemical and nuclear energy chapters and are not meant to be a comprehensive review. Topics covered in these
ABSORPTION OF BETA AND GAMMA RADIATION
ABSORPTION OF BETA AND GAMMA RADIATION The purpose of this experiment is to understand the interaction of radiation and matter, and the application to radiation detection and shielding Apparatus: 137 Cs
Synthetic Sensing: Proximity / Distance Sensors
Synthetic Sensing: Proximity / Distance Sensors MediaRobotics Lab, February 2010 Proximity detection is dependent on the object of interest. One size does not fit all For non-contact distance measurement,
PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS
PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS 1. Photons 2. Photoelectric Effect 3. Experimental Set-up to study Photoelectric Effect 4. Effect of Intensity, Frequency, Potential on P.E.
EXPERIMENTAL CONDITIONS FOR CROSS SECTION MEASUREMENTS FOR ANALYTICAL PURPOSES. L. Csedreki 1. Abstract. I. Introduction
ACTA PHYSICA DEBRECINA XLVI, 25 (2012) EXPERIMENTAL CONDITIONS FOR CROSS SECTION MEASUREMENTS FOR ANALYTICAL PURPOSES L. Csedreki 1 1 Institute of Nuclear Research of the Hungarian Academy of Sciences,
Overview of Proton Beam Cancer Therapy with Basic Economic Considerations
Overview of Proton Beam Cancer Therapy with Basic Economic Considerations Wayne Newhauser, Ph.D. Proton Therapy Project, Houston Cyclotron 235 MeV 300 na Extraction Channel Radial Probe Energy Degrader
Basic Nuclear Concepts
Section 7: In this section, we present a basic description of atomic nuclei, the stored energy contained within them, their occurrence and stability Basic Nuclear Concepts EARLY DISCOVERIES [see also Section
Chapter 17: Radioactivity and Nuclear Chemistry
Chapter 7: Radioactivity and Nuclear Chemistry Problems: -20, 24-30, 32-46, 49-70, 74-88, 99-0 7.2 THE DISCOVERY OF RADIOACTIVITY In 896, a French physicist named Henri Becquerel discovered that uranium-containing
Tom Wilson Product Marketing Manager Delivery Systems Varian Medical Systems International AG. CERN Accelerator School, May 2015
INDUSTRIAL DESIGN Tom Wilson Product Marketing Manager Delivery Systems Varian Medical Systems International AG VARIAN ONCOLOGY SYSTEMS 1 VARIAN ONCOLOGY SYSTEMS CERN Accelerator, May 2015 Industrial Design
Introduction to Geiger Counters
Introduction to Geiger Counters A Geiger counter (Geiger-Muller tube) is a device used for the detection and measurement of all types of radiation: alpha, beta and gamma radiation. Basically it consists
K O M A C. Beam Commissioning of 100-MeV KOMAC Linac. Korea Multi-purpose Accelerator Complex 양 성 자 가 속 기 연 구 센 터
LINAC14, Geneva Beam Commissioning of 100-MeV KOMAC Linac Yong-Sub Cho for KOMAC accelerator team September 2, 2014 KOMAC, KAERI 0 Outline KOrea Multi-purpose Accelerator Complex Facility Introduction
2. John Dalton did his research work in which of the following countries? a. France b. Greece c. Russia d. England
CHAPTER 3 1. Which combination of individual and contribution is not correct? a. Antoine Lavoisier - clarified confusion over cause of burning b. John Dalton - proposed atomic theory c. Marie Curie - discovered
X Ray Flourescence (XRF)
X Ray Flourescence (XRF) Aspiring Geologist XRF Technique XRF is a rapid, relatively non destructive process that produces chemical analysis of rocks, minerals, sediments, fluids, and soils It s purpose
Cancer Therapy with Particle Beams
Cancer Therapy with Particle Beams The potential to use high energy particle beams to treat many types of cancer has been known even before their creation. The availability of these treatments has been
Lectures about XRF (X-Ray Fluorescence)
1 / 38 Lectures about XRF (X-Ray Fluorescence) Advanced Physics Laboratory Laurea Magistrale in Fisica year 2013 - Camerino 2 / 38 X-ray Fluorescence XRF is an acronym for X-Ray Fluorescence. The XRF technique
Principles of dosimetry The ionization chamber
Principles of dosimetry The ionization chamber FYS-KJM 4710 Audun Sanderud Department of Physics Ionometry 1) Ionometry: the measurement of the number of ionizations in substance The number of ionizations
GAMMA-RAY SPECTRA REFERENCES
GAMMA-RAY SPECTRA REFERENCES 1. K. Siegbahn, Alpha, Beta and Gamma-Ray Spectroscopy, Vol. I, particularly Chapts. 5, 8A. 2. Nucleonics Data Sheets, Nos. 1-45 (available from the Resource Centre) 3. H.E.
Medical Physics and Radioactivity
Medical Physics and Radioactivity Radioactivity Unstable nucleus Electromagnetic wave particle Atoms which emit electromagnetic radiation or a particle by the spontaneous transformation of their nucleus
HIGH CURRENT OPERATION OF THE ACSI TR30 CYCLOTRON
HIGH CURRENT OPERATION OF THE ACSI TR30 CYCLOTRON 18 th International Conference on Cyclotrons and their Applications, Sicily, 2007 Vasile Sabaiduc, Project Manager, RF Senior Engineer Advanced Cyclotron
Chapter NP-1. Nuclear Physics. Atomic Nature of Matter TABLE OF CONTENTS INTRODUCTION OBJECTIVES 1.0 PROPERTIES OF SUBSTANCES
Chapter NP-1 Nuclear Physics Atomic Nature of Matter TABLE OF CONTENTS INTRODUCTION OBJECTIVES 1.0 PROPERTIES OF SUBSTANCES 1.1 CHEMICAL AND PHYSICAL PROPERTIES 2.0 COMPOSITION OF ATOMS 2.1 ATOMIC STRUCTURE
Institute of Accelerator Technologies of Ankara University and TARLA Facility
Institute of Accelerator Technologies of Ankara University and TARLA Facility Avni Aksoy Ankara University [email protected] On behalf of IAT & TARLA Team Contents Brief history of TAC project Institute
Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13
Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis Tushita Patel 4/2/13 Breast Cancer Statistics Second most common cancer after skin cancer Second leading cause of cancer
Basic Concepts in Nuclear Physics
Basic Concepts in Nuclear Physics Paolo Finelli Corso di Teoria delle Forze Nucleari 2011 Literature/Bibliography Some useful texts are available at the Library: Wong, Nuclear Physics Krane, Introductory
Nuclear Medicine & PET Research. F Production. Radiochemie.nl Cursus 18 F chemie
18 F Production 1 Outline Cyclotron technique 18 F targetry : Fluoride and Fluorine production 2 Main PET Isotopes 11 C : 20 min, b + ( 970 KeV ), 14 N(p,a) 11 C 13 N : 10 min, b + ( 1190 KeV ), 16 O(p,a)
Introduction to Nuclear Physics
Introduction to Nuclear Physics 1. Atomic Structure and the Periodic Table According to the Bohr-Rutherford model of the atom, also called the solar system model, the atom consists of a central nucleus
The photoionization detector (PID) utilizes ultraviolet
Chapter 6 Photoionization Detectors The photoionization detector (PID) utilizes ultraviolet light to ionize gas molecules, and is commonly employed in the detection of volatile organic compounds (VOCs).
Status of High Current Ion Sources. Daniela Leitner Lawrence Berkeley National Laboratory
http://ecrgroup.lbl.gov Status of High Current Ion Sources Daniela Leitner Lawrence Berkeley National Laboratory October, 27th, 2003 1 Content Overview of available high current sources Requirements for
Lesson 43: Alpha, Beta, & Gamma Decay
Lesson 43: Alpha, Beta, & Gamma Decay The late 18s and early 19s were a period of intense research into the new nuclear realm of physics. In 1896 Henri Becquerel found that a sample of uranium he was doing
Instrumentation. (Figure 2)
X-Ray Fluorescence Lab Report Nydia Esparza Victoria Rangel Physics of XRF XRF is a non destructive analytical technique that is used for elemental and chemical analysis. X-Ray Fluorescence Spectroscopy
Instructors Guide: Atoms and Their Isotopes
Instructors Guide: Atoms and Their Isotopes Standards Connections Connections to NSTA Standards for Science Teacher Preparation C.3.a.1 Fundamental structures of atoms and molecules. C.3.b.27 Applications
PHYA5/1. General Certificate of Education Advanced Level Examination June 2012. Unit 5 Nuclear and Thermal Physics Section A
Centre Number Surname Candidate Number For Examinerʼs Use Other Names Candidate Signature Examinerʼs Initials General Certificate of Education Advanced Level Examination June 2012 Question 1 2 Mark Physics