- Views:
Transcription
1 Safe.t Technology Safe.t Seminars Safe.t Solutions Safe.t Components Solutions Safe.t Components Safe.t Systems Safe.t Technology Safe.t Seminars Safe.t Technology Safe.t Seminars Safe.t Solutions Safe.t Components t Solutions Safe.t Components Safe.t Systems Safe.t Technology.t Systems Safe.t Technology Safe.t Seminars Safe.t Solutions Safe.t Components Field equipment, enclosures and systems
2 BARTEC TECHNOR AS is a part of the BARTEC Group, one of the world s leading vendors of industrial safety technology. BARTEC TECHNOR was established in 1983 in Stavanger, Norway, and is a recognized manufacturer of equipment and systems for use in hazardous areas. BARTEC TECHNOR is trusted by many of the world s foremost companies as a preferred supplier of equipment for potentially explosive atmospheres. BARTEC TECHNOR s main clients are Contractors, System Integrators, Oil Companies and OEMs. BARTEC TECHNOR focuses on developing innovative and technologically advanced solutions to the challenges our customers are facing by combining expertise in electronic engineering with over 25 years experience at the forefront of Hazardous Area protection concepts. 2
3 Table of Contents Ex-Regulations 4 Engineering and Customer Based Product Solutions 18 Pressurized Systems and Cabinets 21 Terminal Boxes 23 Flameproof Enclosures 27 Pressurized Systems and Cabinets 35 Audible and Visual Signals 37 Lighting 45 Plugs and Sockets 51 Gas Detection 57 Reservations of failure and changes in the catalogue. Doc.no.: 122-DIV-5, Rev. D (printed edition) Editing completed February
4 Ex Regulations Explosive Atmosphere regulation Explosion Protection An explosive atmosphere is built up by a mixture of ammable gases, vapours, mists or dust with atmosphere air. If the mixture ( ammable substances/air) has the right ratio it can be ignited by a ignition source and create an explosion. Factors for creating an explosion: 1. Air (or in fact oxygen in the air) 2. Flammable material (substance) 3. Ignition source Ignition Material Air There are two main principles to avoid an explosion; primary and secondary precautions. When an ignition source is present primary explosion protection can be achieved by: - Using natural or forced ventilation to limit the explosive concentration - Avoiding ammable materials (substance) - Using inert gas in the atmosphere (e.g. Nitrogen) If still an explosive atmosphere can be created in a area, Ignition Control is the alone way of avoiding explosion. Type of Ignition Sources Hot surfaces Flames and hot gases Mechanically produced sparks Electrical equipment Transient currents Static electricity Lightning strikes Electromagnetic waves Optical radiation Ultrasound Chemical reactions People (indirectly) The techniques of equipment protection for use in explosive atmospheres are just a matter of controlling (eliminating) possible ignition sources (secondary explosion protection) 4
5 Ex Regulations Explosive Atmosphere regulation Where do we nd explosive atmospheres? Metal surface grinding, especially aluminium dust and particles Oil re neries, rigs and processing plants Gas pipelines and distribution centres Printing industries, paper and textiles Aircraft refuelling and hangars Chemical processing plants Grain handling and storage Sewage treatment plants Surface coating industries Underground coalmines Woodworking areas Sugar re neries Vessels/ships Power plants Where a potential explosive atmosphere can occur, certain safety levels need to be taken into account regarding the possible danger of an explosion in this area. The areas therefore need to be divided into zones according to presence of the ammable substances. Zone 0 Zone 1 Zone 2 A place in which an explosive atmosphere consisting of a mixture with air of ammable substances in the form of gas, vapour or mist is present continuosly or for long periods or frequently. A place in which an explosive atmosphere consisting of a mixture with air or ammable substances in the form of gas, vapour or mist is likely to occur in normal operation occasionally. A place in which an explosive atmosphere consisting of a mixture with air of ammable substances in the form of gas, vapour or mist is not likely to occur in normal operation, but - if it does occur - will persist for a short period only. Explosive atmosphere for more than 1000 h/yr. Explosive atmosphere for more than 10, but less than 1000 h/yr. Explosive atmosphere for less than 10 h/yr Zone 20 Zone 21 Zone 22 A place in which an explosive atmospere in the form of cloud of combustible dust in air is present continously, or for long periods or frequently. A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is likely to occur in normal operation occasionally. A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is not likely to occur in normal operation, but - if it does occur - will persist for a short period only. 5
6 Ex Regulations Explosive Atmosphere regulation Examples of the criteria for the mixture of ammable substances (gas) towards air in such a way that an explosion can occur are: 100 Vol% Concentration of Air 0 Vol% Mixture too lean Explosion range Mixture too rich Explosion lower limit higher 0% 100% LEL UEL 0 Vol% Concentration of ammable substances 100 Vol% Typical concentration of gases/vapours in the air where an explosion can appear (% vol. of gas in air): LEL Explosion UEL (IEC ) Methane 4.4% 16.5% Propane 1.7% 10.6% Butane 1.4% 9.3% 1. LEL (Lower Explosive Limit) 2. UEL (Upper Explosive Limit) 3. Optimum mixture 4. MIE: Minimum Ignition Energy 6
7 Ex Regulations Atex Directive Atex directive - Product Directive 1994/9/EC - User Directive 1999/92/EC Equipment Directive 1994/9/EC This directive has been mandatory in Europe from , and covers the regulations concerning equipment and protective systems for use in potentially explosive atmospheres. This directive has four chapters which are subdivided into 16 articles. In each chapter it is made reference to the Annex I to XI, which include 7 modules. For full info visit Content of directive 94/9/EC Main part Chapter Article Heading I 1-7 Scope of application, placed in service and free movement of goods II 8 9 Conformity assessment procedures III CE marking of conformity IV Concluding provisions Annexes I II III IV V VI VII VIII IX X XI Criteria determining the classi cation decision of equipment groups in categories Essential safety and health requirements for the design and construction of equipment and protective systems for use in potentially explosive atmospheres Module: EC-type examination Module: Production Quality assurance Module: Product veri cation Module: Conformity to type Module: Product Quality assurance Module: Internal control of production Module: Unit veri cation CE marking and contents of the EC declaration of conformity Minimum criteria to be taken into account by member states for the noti cation of bodies 7
8 Ex Regulations Atex Directive The directive 1994/9/EC is dividing the equipment into groups and categories. - Equipment Group I applies for mining. This group is subdivided into categories M1 & M2. - Equipment Group II applies for all others (surface) areas. This group is subdivided into categories 1, 2 and 3. Note: Equipment group III applies to dust atmospheres according to EN/IEC Group Mining Industries Group Regular industries (gas + dust hazardous areas) Category M1 Category M2 Category 1 Category 2 Category 3 Very high level of protection (safe with 2 faults) Equipment to conform with the Atex Directive 94/9/EC Must remain functional under speci c explosive atmosphere concentration High level of protection (safe with 1fault) De-energized under speci c explosive atmosphere concentration Very high level of protection (safe with 2 faults) Marking I M1 I M2 II 1 G (Gas) II 1 D (Dust) High level of protection (safe with 1 fault) II 2 G (Gas) II 2 D (Dust) Normal level of protection (safe during normal operation) II 3 G (Gas) II 3 D (Dust) Electrical Equipment Area Zone Equipment Category How to comply The manufacturer must evaluate the equipment according to valid standard/directives, and create a technical le and subsequently issuing an EC D.O.C (Declaration of Conformity) EC-type examination certi cate from NB (Noti ed Body, DNV, Nemko, INERIS e.g.) EC-type examination certi cate from NB (Noti ed Body, DNV, Nemko, INERIS e.g.) Production requirements The manufacturer needs to ensure a production quality The manufacturer needs to have a production quality system and obtain a Production Quality Assurance Noti cation from NB (Noti ed Body) Non-electrical equipment Area Zone Equipment Category How to be in compliance with the Atex Directive To be veri ed by the manufacturer and issue a Technical File Manufacturer to issue EC D.O.C. To be veri ed by manufacturer and submit technical le to NB (Nemko, DNV, INERIS e.g.) Manufacturer to issue EC D.O.C. To be certi ed by NB, EC-type examination certi cate from NB (Noti ed Body, DNV, Nemko, INERIS e.g.) Manufacturer to issue EC D.O.C. 8
9 Ex Regulations Atex Directive Marking Con rmation that the equipment ful l CE all valid EU directives 0470 Ref. no. for NB (production licence) European conformity certi cate II Equipment group 2 Category G For use in gas atmosphere D For use in dust atmosphere Atex Marking IECEx Marking Note: The equipment also needs to be marked with the conventional protection mode (Ex ) according to EN/IEC (EN/IEC or for dust atmospheres) Operating instruction/user manual; The operating instructions of the manufacturer must clearly de ne the intended use of the equipment by the operator. The minimum requirements for the operating instruction are amongst others: - Information about safety aspects - Installation - Putting into service - Use - Assembling and dismantling - Maintenance (servicing and emergency repair) Adjustment - Manufacturer s Declaration of Conformity (EC D.O.C.) Equipment and protective systems can be placed on the market, only if marked with the CE mark and complete with operating instructions and the manufacturer s Declaration of Conformity. The CE conformity marking and the issued Declaration of Conformity con rm that the equipment complies with all requirements and assessment procedures speci ed in the EC Directives. Note: According to Directive 94/9/EC the mandatory evidence of complying with this is given in the EC D.O.C. including the operating instructions. 9
10 Ex Regulations Atex Directive User Directive 1999/92/EC This directive gives the minimum requirement for improving the safety and health protection of workers potentially at risk from explosive atmospheres. The main issues to be addressed; - Assessment of explosion risk - Zone classi cation - Explosion protection documents (including requirements for personnel to do engineering, equipment selection, installation, maintenance, repair etc.) Structure of Directive 1999/92/EC Ruling part Section Article Heading I 1-2 General provisions II 3-9 Obligations of the employer 3 Prevention of and protection against explosions 4 Assessment of the explosion risks 5 General obligations 6 Duty of coordination 7 Places where explosive atmosphere may occur 8 Explosion protection document 9 Special requirements for work equipment and workplaces III Other requirements Annexes I Classi cation of places where explosive atmospheres may occur 1. Places where explosive atmospheres may occur 2. Classi cation of hazardous places II A Minimum requirements for the improvement of the safety and health protection of employees who could be endangered by III B explosive atmospheres 1. Organizational measures 2. Explosion protection measures Criteria for the selection of equipment and protective systems Warning signs for marking areas in which explosive atmospheres can occur For further information (Directive 1999/92/EC and user guide) please visit; Marking of Hazardous places 10
11 Ex Regulations Ignition Sources Classi cation of Ignition Sources for gas and vapour Hot Surfaces Ignition Temperature Sparks Ignition Energy Temperature Class T1... T6 Gas Group A... C Temperature Class Temperature Class Maximum Surface Temperature (at max. ambient temperature) T1 450 C T2 300 C T3 200 C T4 135 C T5 100 C T6 85 C Energy Classi cation Minimum Ignition Energy European Groups USA/Canada Groups Gas / Vapour < 20 Joules A Acetylene, Carbon disulphide C < 20 Joules B Hydrogen < 60 Joules B C Ethyl ether, Ethylene < 180 Joules A D Acetone, Butane, Ethanol, Gasoline, Hexane, Methanol, Methane, Naphtha, Propane 11
12 Ex Regulations Ignition Sources Standards valid for Electrical Apparatus for Explosive Gas Atmospheres EN (old) EN (current) General requirements EN EN Flameproof enclosures d EN EN Pressurized enclosures p EN EN Powder lling q EN EN Oil immersion o EN EN Increased safety e EN EN Intrinsic safety i EN EN Type of protection n EN EN Encapsulation m EN EN Intrinsically safe systems EN Electrical equipment for Zone 0 EN EN Intrinsically safe eld bus systems EN Optical radiation op EN Standards valid for electrical apparatus for Explosive dust atmosphere Standard EN (IEC) Protection name Protection method General requirement for Dust equipment / td Protected by enclosures pd Protected by pressurization id Protected by intrinsic safety md Protected by encapsulation Standards valid for non-electrical equipment Protection type EN Marking letter Basic method and requirements EN * Flow restricting enclosure EN fr Flameproof enclosure EN d Constructional safety EN c Control of ignition sources EN b Protected by liquid immersion EN k * Will be replaced by ISO/EN Internal combustion engine motors EN EN EN Gas, group II Mines, group I Dust, group II 12
13 Ex Regulations Protection Methods Marking Flameproof enclosures (IEC/EN ) The enclosures are constructed so that internal explosions can not be transmitted to the external atmosphere Ex d Increased safety (IEC/EN ) Prevention of ignition sources by fail safe design (only simple electric components) Ex e Intrinsic safety (IEC/EN ) Limitation of the energy stored in the electrical circuits category ia and ib, simple apparatus, associated apparatus, safety barriers Installation: Safety values (Uo, Io, Po, Lo, Co) and clearances Ex ia/ib/ic Type n (IEC/EN : Zone 2) No ignition source in normal operation (no sparks, no hot surfaces) Oil immersion (IEC/EN ) Electrical parts are submerged in oil Ex na, Non-sparking Ex nc, Protected sparking Ex nr, Restricted breathing Ex nl, Energy limited Ex o Pressurized apparatus (IEC/EN ) Electrical parts are purged and pressurized with a protective gas (air or inert gas) Installation: Purge and pressure control/shut down device Ex px, Gb (to safe area) Ex py, Gb (to Gc) Ex pz, Gc (to safe area) Powder lling (IEC/EN ) Electrical parts are submerged in a quartz powder Ex q Encapsulation (IEC/EN ) Electrical parts are encapsulated in a speci c resin. Ex ma/mb 13
14 Ex Regulations Equipment Protection Level EPL (Equipment Protection Level) according to IEC/EN standard De nition: The level of protection assigned to equipment based on its likelihood of becoming a source of ignition and distinguishing the differences between explosive gas atmospheres, explosive dust atmospheres, and the explosive atmosphere in mines susceptible to redamp. Link between Zones, Atex categories and EPL: Area towards Equipment EPL EN Group Level of protection Directive 94-9-EC Product directive (Atex 100) Equipment Equipment group category Ma Very high M1 I I Mb High M2 Ga Very high EN X Zones Gb II High 2G 1 Occasionally N/A 1G 0 Often/longer periods Directive 99/92/EC User directive (Atex 137) Extent of protective Hazardous quantities measure (Risk) Without speci c methane Safe with 2 faults, rare concentration and foreseen With speci c methane Safe with 1 fault, concentration foreseen Safe with 2 faults, rare and foreseen Safe with 1 fault, foreseen Gc Enhanced 3G 2 Rear/most likely never Normal II Safe with 2 faults, rare Da Very high 1D 20 Often/longer periods and foreseen Db III Safe with 1 fault, High 2D 21 Occasionally foreseen Dc Enhanced 3D 22 Rear/most likely never Normal Why EPL (Atex categories); Historically it has been acceptable to install equipment into speci c zones based on the type of protection. In some cases it has been shown that the type of protection may been divided into different levels of protection that can be correlated against each Zone. A better risk assessment would consider all factors. When using a risk assessment approach instead of the in exible approach of the past linking equipment to Zones the inherent ignition risk of the equipment is clearly indicated, no matter what type of protection is used. An example using a risk assessment approach: Plant operators often make intuitive decisions on extending (or restricting) their Zones in order to compensate for this in exibility. A typical example is the installation of Zone 1 Type navigation equipment in Zone 2 areas of offshore oil production platforms, so that the navigation equipment can remain functional even in the presence of a totally unexpected and prolonged gas release. On the other hand, it is reasonable for the owner of a remote, well secured, small pumping station to drive the pump with a Zone 2 Type motor, even in Zone 1, if the total amount of gas available to explode is small and the risk to life and property from such as explosion can be discounted. The situation became more complex with the publication of the rst edition of IEC which introduced additional requirements to be applied for equipment intended to be used in Zone 0. Prior to this, Ex ia was considered to be the only technique acceptable in Zone 0. It has been recognized that it is bene cial to identify and mark all products according to their inherent ignition risk. This makes equipment selection easier and a risk assessment approach, more appropriate. 14
15 Ex Regulations Marking for Ex equipment New marking for Ex equipment ATEX OLD Gas Atmosphere New IEC :2007/EN :2009 II 2 G Ex/Ex d IIB T6 Ex d IIB T6 Gb or Ex db IIB T6* II 2(1) G Ex/Ex d [ia IIC] IIB T6 Ex d [ia IIC Ga] IIB T6 Gb or Ex db [ia IIC] IIB T6* II 2 G Ex/Ex ia IIC T4 Ex ia IIC T4 Gb or Ex ib IIC T4* II 2 G Ex/Ex e II T4 Ex e IIC T4 Gb or Ex eb IIC T4* ATEX OLD Dust Atmosphere New IEC :2007/EN :2009 II 2 D Ex td A21 IP65 T120 C Ex t IIIC T120 C Db or Ex tb IIIC T120 C* II 2(1) D Ex td [iad] A21 IP65 T120 C Ex t [ia Da] IIIC T120 C Db or Ex tb [ia] IIIC T120 C* II 1 D Ex isd A20 IP65 T120 C Ex ia IIIC T120 C Ga or Ex ia IIIC T120 C* *IEC alternate marking EPL Ga Gb Gc EPL Da Db Dc ameproof enclosure db protected by enclosure ta tb tc increased safety eb intrinsic safety ia ib intrinsic safety ia ib ic encapsulation ma mb encapsulation ma mb pressurization pb pc non-sparking protected sparking restricted sparking energy limited oil immersion pressurization powder lling ob pxb pyb qb nac ncc nrc nlc pzc The Ex marking for explosive gas atmospheres and explosive dust atmospheres shall be separate and not combined: II 1 G - Ex ia IIB T4 II 1 D - Ex ia IIIC T120 C or alternatively: II 1 GD Ex ia IIB T4 Ga Ex ia IIIC T120 C Da 15
16 EX Regulations IP Rating IP Degree of Protection according to EN/IEC First gure Second gure 0 No protection 0 No protection 1 Protected against a solid object 50 mm or greater 1 Protected against vertically dripping water 2 Protected against a solid object 12 mm or greater 2 Protected against vertically dripping water, when tilted 15 degrees 3 Protected against a solid object 2,5 mm or greater 3 Protected against water spraying at an angle up to 60 degree 4 Protected against a solid object 1 mm or greater 4 Protected against water splashing from any direction 5 Dust protected 5 Protected against jets of water from any directions 6 Dust tight 6 Protected against powerful jets of water from any directions 7 Protected against immersion between a depth of 150 mm and 1000 mm 8 Protected against submersion Example IP66 16
17 EX Regulations IP Rating IP - rst character NEMA Enclosure type IP - second character A 1 2 3, 3X, 3S, 3SX 3R, 3RX 4, 4X 5 6 6P 12, 12K, 13 B IP0_ IP_0 IP1_ IP_1 IP2_ IP_2 IP3_ IP_3 IP4_ IP_4 IP5_ IP_5 IP6_ IP_6 IP_7 IP_8 A B A B A B A B A B A B A B A B A B 17
18 Engineering and Customer based product/solution Engineering and Customer based product development Our engineers have a comprehensive level of experience in developing and designing Ex equipment for most applications, and hold a high level of professional competence in this eld. In accordance with our vision, we wish you as our customer to receive the full bene t of this competence through working with us to nd creative and cost effective solutions to your particular needs, thus increasing safety and pro tability for your business. This kind of cooperation also helps to ensure effective implementation of new technology in our market sector. We call this Customer based product development. Our competitive advantage is that we can quickly implement a tailor made solution, from design straight to product certi cation, and deliver the product in small or large production batches. Solutions through technology! From Idea to Solution: Concept study Engineering Prototyping Ex certi cation Documentation Production Delivery BARTEC TECHNOR s Engineering and Customer based activities are divided into the following categories: Standard panels/enclosures Engineering and assembly of standard products Special solutions Mainly engineering and assembly of standard products but with some parts which need to be engineered as tailor made Tailor made solutions These are products or solutions are engineered and designed especially according to the customer s requirements 18
19 Engineering and Customer based product/solution Standard panels/enclosures Engineering and building of a solution based on standard Ex components (with or without incorporation of standard industrial components), such as control panels, switch gears, motor starters etc. Typical examples are: Ex d panels Ex e/ed panels Ex p Ex n (Zone 2 only) Special solution Modifying existing Ex components to be adapted to certain tailor requirements, such as: CCTV applications, Remote I/O panels, HMI applications (LCD display and PC solutions), pressurized systems, wireless measuring systems, light equipment etc. Typical examples can include: Ex d solutions Ex e/ed solutions Ex p Ex n (for Zone 2) Tailor made solutions (are mainly OEM products/solutions) Creating and engineering of solution totally from the very beginning. Typical applications are communication systems including wire, bre optical, wireless transfer, CCTV solutions, measuring systems, different types of switch/control gear, light equipment etc. The range of OEM products are designed to meet the clients demands, and are usually used within an industry where an explosive atmosphere may be present. If you come up with a unique product idea which is going to be used in hazardous area, we can use our long-standing competence and experience within the Ex eld to ensure that you achieve your vision. We can tailor make products using all Ex protection methods in close relationship with our clients and have them veri ed/certi ed for II 3 G/D (Zone 2/ 22), II 2 G/D (Zone 1/ 21), II 1 G/D (Zone 0/ 20) or a combination of these. For certi cation we are using partners such as INERIS, DNV, Nemko, IMQ etc. BARTEC TECHNOR can offer you more than 20 years of experience with tailor made Ex products. 19
20 Engineering and Customer based product/solution This is how we can carry out a project: Analyse the needs and valid directives/regulations Develop initial ideas for the project covering the following: - Mechanical (including IP NEMA rating, extreme temperature range, involved materials etc) - Electrical - Method of Ex protection - Budget price Create a model of the solution - 2D or 3D format Generation of prototypes for validation, if necessary Ex certi cation (certi cate to be issued by Noti ed Bodies/Certi cation Bodies) - Atex - IECEx - Gost - Others (North America, South America etc.) Creating product documentation including: - Production documentation - Production procedures - CE veri cation - Declaration of Conformity - User manual - Other relevant demands for equipment to be used in hazardous area Our client can receive the product from our production facilities as a part product or a fully functional product. These can be delivered as follows: - The product labelled with BARTEC TECHNOR - The product labelled under the name of the client (this solution requires a production license in the name of the product owner) The client will receive a product that meets the requirements for use in hazardous area without requiring his own competence regarding Ex or production setup for such products. 20
21 Project Shedule Pressurized Cabinets and Systems Pressurized cabinets and systems (Ex p) A typical project schedule for a pressurized system can be as follows: Analysing the speci c requirements from the client and clarifying these with the client. This includes details such as environment conditions, material strength, physical dimensions, electrical requirements, etc. An important task at this stage is also to verify that all client s requirements can be solved within the actual Ex standards and directives. Construction of the actual panel/cabinet according to the demands and speci cations from the client. Selecting the correct control systems according to the demands and speci cations given by the client, such as required cooling, limitation in purge time, how much air/ inert gas is available etc. At this point, any shut-down requirements need to be addressed and taken into consideration before the actual control system is selected. When the client has approved the construction-plans, the actual panel/ cabinet can be manufactured. Then the physical assembly of the system can start in our specialised manufacturing facility with skilled personnel, including the internal components (including possible free issue items) which are to be protected by pressurisation and the purge/ex p control system. Adjusting of control system parameters so that the pressurised control system functions correctly according to all requirements. Ful lling all purge and temperature tests according to the mandatory standards (EN/IEC and ). Final functional test. Creating the required documentation package, including all client requirements. Write the user manual, as a minimum to meet the requirements in EN/IEC and and the Directive 94/9/EC (ATEX Directive). Applying for the Certi cate of Conformity. Issuing the EC Declaration of Conformity (EC D.O.C.). Handover (eventual FAT: Final Acceptance test) and delivery of the complete system. 21
22 22
23 Terminal Boxes TNCN Junction boxes, Ex e/i, Stainless steel 316L 24 23
24 Terminal Boxes TNCN The TNCN range of stainless steel 316L Ex e enclosures are designed for use in any environment where an explosive atmosphere may be present and are especially recommended for chemical agent environments, seawater corrosion resistance and extremes of low and high temperature. Speci cations Material Stainless steel 316L IP Rating IP66 (IP67 and IP68 upon request) Ambient temperature -20ºC to +40ºC (T5) Option: -20ºC to +60ºC (T6/T4) -50ºC to +60ºC Approvals - Atex DNV-2001-OSL-ATEX-0176 DNV-2008-OSL-ATEX-42438U - IECEx IECEx DNV U IECEx DNV CSA CSA Brazilian 09/UL-BRCN GOST GOST Certi cate Standards EN/IEC: , EN: , Ex-Code Ex e II T6/T4 / Ex [ia] IIC T6 Ex td A21 T85ºC - T110ºC II 2 GD and EPL Gb/Db Cover gasket Silicone (temp. -50ºC to +200ºC) Surface treatment Acidized as standard Electropolished as an option Material thickness Min. 1.5 mm (depending on the box size) Earthing Internal earth bar/bracket External earth bracket Drain Plug Optional Gland Plate Optional 24 Fixing dimensions Box type X (mm) Y (mm) Type A Width (cm) Terminal box: maximum heat dissipation - number of terminals Box type Maximum heat dissipation Max. dissipated power at Tamb=40 C W W W W W W W W The maximum dissipated power level for terminal box sizes not listed in the above table is equal to the nearest smaller size box. TNCN Range of stocked boxes B Height (cm) C Depth (cm) Volume (dm 3 ) Weight (kg) ** ** TNCN Measurement Table range of stocked boxes. Other sizes are available upon request. The boxes are delivered as standard with left hinged covers held to the enclosure by screws. Quick locks, screws only, or other systems can be delivered upon request. ** No hinges screws only
25 Terminal Boxes TNCN A or B Width/ Height (cm) C Depth (cm) M20 M Entry Matrix This table lists our recommendations for the maximum quantity of glands for installation in 1 face (the width column in the table) on TNCN Junction Boxes. Note: MCT-frames can be tted in boxes with a minimum depth of 20 cm. Dimensions TNCN / TNCN Top/Bottom Side (L+R) Box A B C D
26 26
27 Flameproof Enclosures TNCD Enclosure, Ex d/de, Stainless steel 316L TNXCD Cylindrical Enclosure, Ex d/de, Stainless steel 316L DE8WH Enclosure, Ex d/de, painted carbon steel TNBCD Enclosure, Ex d/de, Stainless steel 316L DE8BC Enclosure, Ex d/de, painted carbon steel or Stainless steel 316L
28 Flameproof Enclosures TNCD The TNCD range of enclosures are manufactured in SS316L and are designed to meet the requirements for Ex d IIC equipment in harsh environments on and offshore. Can be con gured as Ex d direct entry or as an Ex de combination for indirect entry. Speci cations Material Stainless Steel 316L IP Rating IP66 (IP67 upon request) Ambient temperature -20ºC to +40ºC (T6), Option -40ºC to +60ºC Approvals - Atex NEMKO 03ATEX263U DNV-2003-OSL-ATEX-0135 Standards EN/IEC: , Ex-Code Ex d IIC/IIB T6 T4 Ex de IIC/IIB T6 - T4 II 2 G/D or II 2(1/2)G/D Lid gasket Viton Surface treatment Shot blasted Earthing between Ex d and Ex e/i Through the ange assembly enclosures Cover With or without hinges, depending on size Measurement table for Ex d IIC Explosion proof enclosures TNCD Internal dimensions A B C D Ø a b c Width Height Depth Total Weight Window Width Height Depth TNCD (mm) (mm) (mm) depth kg (mm) (mm) (mm) (mm) / / / / / /100/ /100/ Viewing window TNCD Viewing windows are available in the following diameters: 65mm, 100mm and 154mm. The window is placed in the centre of the lid. Windows (Ø65) can also be placed on the sides or back wall. Range of Ex e connection boxes (optional) TNCC E Width (mm) F Heigth (mm) G Depth (mm) Kg Weight Dimensions 28
29 Flameproof Enclosures TNXCD The TNXCD range of Ex d / de IIC enclosures are manufactured in SS316L and are designed as slim, compact, multipurpose enclosures. Typical applications CCTV camera housing. Speci cations Material Stainless steel 316L IP Rating IP66 (IP67 and IP68 upon request) Ambient temperature -20ºC to +40ºC Option: -50ºC to +60ºC Approvals - Atex, Empty enclosure DNV-2003-OSL-ATEX-0436-U - Atex, Complete enclosure DNV-2004-OSL-ATEX-0115 Standards EN/IEC: , , Ex-Code empty enclosure Ex d IIC/Ex de IIC, II 2 G Earthing between Ex d and Ex e enclosure Through the ange assembly Entries Ex e glands and Ex d bushings, or Ex d glands only Gland Size Ex e M25 Gland Size Ex d According to speci cation Bushing Ex d Max M42, number and core size acc. to spec. TNXCD Dimensions Total length (mm) TNXCD Ex d A B C D E F Ø Tube length Diameter Internal dia. Internal Junction Weight (kg) (mm) (mm) (mm) length box Window/Dome (mm) XCD N/A XCD N/A XCD N/A XCD N/A XCD N/A XCD N/A TNXCD Total length (mm) TNXCD Ex de A B C D E F Ø Tube length Diameter Internal dia. Internal Junction Weight (kg) (mm) (mm) (mm) length box Window/Dome (mm) XCD XCD XCD XCD XCD XCD Available with window, Dome or SS316 top 29
30 Flameproof Enclosures DE8WH The DE8WH range of Ex d IIC enclosures range comprises many standard sizes of enclosures manufactured in painted carbon steel. Can be con gured as Ex d direct entry or as an Ex de combination for indirect entry. If required, several enclosures can be assembled on a frame with separate or common Ex e/i junction boxes. The enclosures can be delivered empty with U component certi cate or supplied fully assembled according to client demands. Speci cations Material Carbon steel IP Rating IP65 Ambient temperature 20 C to +40 C Option: -20 C to +50 C -20 C to +60 C Approvals - Atex INERIS 03ATEX0121X Standards EN/IEC: , , , , EN: , Ex-Code Ex d IIC or de IIB T6 to T4 IP6X - T85 C to T135 C ATEX II 2 GD or 2 (1) GD Ex d [ia] or d [ia] ia or de [ia] or de [ia] ia IIB T6 IP6X T85 C Surface treatment RAL 7032 Painting - Special painting on request. Drain plug Upon request Measurement table for Ex d IIC Explosion proof enclosure Reference DE8WH Width A Height B Door Ø Depth H Useful Depth P Fixing points A1 x B1 Diameter of xing holes Base plate useful surface I x J Max. dissipation W DE8WH x800 Ø x DE8WH x552 Ø x DE8WH x400 Ø x DE8WH x210 Ø x DE8WH x305 Ø 9 Ø DE8WH x305 Ø 9 Ø Weights Empty kg Dimensions 30
31 Flameproof Enclosures TNBCD The TNBCD range of enclosures are manufactured in SS316L and are designed to meet the requirements for Ex d IIB equipment in harsh environments on and offshore. Can be con gured as Ex d direct entry or as an Ex de combination for indirect entry. Speci cations Material Stainless Steel 316L IP Rating IP66 (IP67 and IP68 upon request) Ambient temperature 20ºC to +50ºC (T6) Option -50ºC to +60ºC Approvals - Atex NEMKO 03ATEX264U DNV-2003-OSL-ATEX-0136 Standards IEC/EN: , Ex-Code Ex d IIC/IIB T6 T4 II 2 G/D or II 2(1/2)G/D Lid gasket Viton Surface treatment Shot blasted Earthing between Ex d and Ex e/i Through the ange assembly enclosures Cover With or without hinges, depending on size Range of for Ex d IIB Explosion proof enclosures TNBCD A Width ( xing) (mm) B Height ( xing) (mm) C Depth (mm) TNBCD Weight Kg Ø Window (mm) # Window (mm) Internal dimensions a Wide (mm) b Height (mm) / x / x c Depth /100/ x /100/ x Measurement table for Ex e connection boxes (optional) Dimensions TNCC E (mm) F (mm) G (mm) (mm) Weight (kg) 31
32 Flameproof Enclosures DE8BC The DE8BC range of Ex d IIB enclosures range comprises many standard sizes of enclosures manufactured in painted carbon steel or SS316L. Can be con gured as Ex d direct entry or as an Ex de combination for indirect entry. If required, several enclosures can be assembled on a frame with separate or common Ex e/i junction boxes. The enclosures can be delivered empty with U component certi cate or supplied fully assembled according to client demands. Speci cations Material Carbon steel or stainless steel 316L IP Rating IP65 as standard Ambient temperature 20 C to +40 C Option: +50 C, +60 C Approvals - Atex INERIS 03ATEX0005X INERIS 09ATEX9017U Standards EN/IEC: , , , , EN: , Ex-Code Ex d IIB or de IIB T6 to T4 IP6X +40 C T85 C to T135 C ATEX II 2 GD or 2 (1) GD Ex d [ia] or d [ia] ia or de [ia] or de [ia] ia IIB T6 IP6X T85 C Surface treatment SS316L are shot blasted Carbon steel are painted RAL 7032 Drain plug Upon request Measurement table for DE8BC, Ex d IIB Explosion proof enclosure Reference DE8BC Width A Height B Depth C Useful Depth C1 Fixing points H1 x L1 Dia meter of xing holes Base plate useful surface H x L Max. dissipation W Weights empty kg DE8BC x326 Ø x DE8BC x346 Ø x DE8BC x426 Ø x DE8BC x526 Ø x DE8BC x526 Ø x DE8BC x526 Ø x DE8BC x630 Ø x DE8BC x734 Ø x DE8BC x868 Ø x DE8BC x868 Ø x DE8BC x900 Ø x Windows for DE8BC Dimensions References Dimensions REG 100 x 50* 100 x 50 REG 100 x 100* 100 x 100 REG 200 x 45* 200 x 45 REG 235 x 75* 235 x 75 REG D45 ø 45 REG D60 ø 60 REG D150 ø 150 *Horizontal arrangement as standard 32
33 Flameproof Enclosures DE8BC Dimensions for DE8BC, Ex d enclosures with enclosed Ex e box Type Type Ex e box TNCN/TNCC* D H I J No. of M42x1,5 holes DE8BC32 TNCC DE8BC351 TNCC DE8BC43 TNCC DE8BC44 TNCC DE8BC54 TNCC DE8BC64 TNCC DE8BC75 TNCC DE8BC86 TNCC DE8BC107 TNCC DE8BC108 TNCC DE8BC148 TNCC * Stainless steel 316L 33
34 34
35 Pressurized Systems TNCNP Cabinets Pressurized System, Ex p, Stainless steel 316L 37 35
36 36
37 Pressurized Systems TNCNP Cabinets The TNCNP range of Ex p pressurized systems are designed and purpose built according to each client s requirements. The equipment allows for use of standard (non-ex) electrical components in zone 1 and 2. BARTEC TECHNOR delivers a variety of turn-key solutions with enclosures made in Stainless steel 316L complete with purge control apparatus, testing and certi cation. Speci cations Material Stainless steel 316L IP Rating IP66-67 Ambient temperature -20ºC to +40ºC Option: -50ºC to +60ºC Approvals - Atex, Complete enclosures DNV-2003-OSL-ATEX Atex, Empty enclosures DNV-2003-OSL-ATEX-0027U Standards EN/IEC: , Ex-Code Ex p II II 2 G Lid/Door gasket Silicone (temp. to +200ºC) Surface treatment Acidized as standard Electro polished as option * Without Ex p control unit: IP66-67 With Ex p control unit tted: IP65 Dimensions 37
38 38
39 Audible and Visual Signals TNFCD, TNFAD, TNFCDM Flashing beacons, Ex d/de, Stainless steel 316L 40 TNDSP-25 Ex bell Ex bell, Ex de, Antistatic Polyamide 43 39
40 Audible and Visual Signals TNFCD/TNFAD/TNFCDM The TNFCD range of ashing beacons are designed to withstand harsh offshore environments. They are suitable for areas where an explosive atmosphere may be present and the need for warning is required. TNFCD ashing beacons are available as Ex de indirect entry, Ex d direct entry or as Non-Ex. Special applications can be designed upon request. Speci cations Material TNFCD/TNFCDM Stainless steel 316L TNFAD Seawater resistant aluminium IP Rating IP66 (IP67 upon request) Ambient temperature -50ºC to +60ºC Approvals - Atex NEMKO 01ATEX430 Standards EN/IEC: , , Ex-Code Ex d IIC T4 or Ex de IIC T4, II 2 G/D Surface treatment Shot blasted Earthing Inside and outside Cable entry TNFCD/TNFAD Standard M25 Cable entry TNFCDM Standard M25, M20 or ying lead upon request Real humidity 100% Dome colours Red, yellow, Blue, Green, Orange, Clear Flash frequency 1 Hz Flash energy TNFCD/TNFAD 10 joule TNFCDM 5 joule Weight TNFCD 5.1 Kg TNFAD 2.5 Kg TNFCDM 2.5 Kg Electrical data TNFCD/TNFAD Rated Voltage VAC VAC 24-48VDC Voltage Range ±10% ±10% ±20% Rated current 110mA 220mA 24VDC: 670mA 48VDC: 330mA Power consumption 24VA 24VA 16VA Frequency 50/60 Hz 50/60 Hz Typical start current >1A in max 1msec. Triggering Direct, Telephone, 24-48VDC, Fail safe Fuse 1-2 A time-lag fuse is recommended Siren card for acoustic warning 8W, 20W or 25W for Ex loudspeaker (8 ohm, 20 ohm or 100V line) Electrical data TNFCDM Rated Voltage VAC VAC 24VDC 48VDC Voltage Range VAC ±20% ±20% ±20% Power consumption 100mA 380mA 200mA Triggering Direct Typical start current 1A in max 1msec 40
41 Audible and Visual Signals TNFCD/TNFAD/TNFCDM Dimensions 41
42 42
43 Audible and Visual Signals TNDSP-25 Ex bell The TNDSP Ex d electronic speaker is con gured with traditional mechanical bell sound. With no moving parts it is the ideal replacement for standard mechanical Ex protected alarms or bells. Speci cations Material Antistatic polyamide, bracket in SS316L IP Rating IP66 Operating temperature -20ºC to +40ºC Approvals - Atex Nemko 03ATEX1357 Standards EN/IEC: , , Ex-Code Ex de IIB + H 2 T5 II 2 G Earthing Internal M4 Entries 1xM20 + 1xM25 plugged Connections 2.5mm² max Power 25W Power consumption 19.6W (8W, 1kHz sine wave) Sound level P112 db Rated current Max 2 Amp. Operating voltage 24VDC ( VDC) EMC protection EN / EN Upon request Other sound effects Colour Black Sound Characteristics for TNDSP-25-Ex bell Dimensions 43
44 44
45 Lighting TNXCX Floodlight, Ex d/de, Stainless steel 316L 46 TNCLS Level Gauges, Ex em, Stainless steel 316L 49 45
46 Lighting TNXCX The TNXCX Ex d IIC low pro le Xenon helideck oodlights are manufactured in stainless steel 316L and are developed to withstand harsh offshore environments while providing safe, powerful illumination with no glare (e.g. to pilots or crew). High quality internal electronics provide a reliable and long-life light source to minimize maintenance. Speci cations Material Stainless steel 316L Aluminium available upon request IP66, IP67 upon request IP Rating Ambient temperature -50ºC to +50ºC Approvals - Atex DNV-2004-OSL-ATEX Standards EN/IEC: , , EN CAP437 Ex-code Ex d/ex de IIC/IIB, II 2 G / D, T4 Suitable for Zone 1 and 2 Entries Ex e glands M25 or M20, or blanking plugs Gland Size Ex e Lamp Operating voltage Power consumption Weight Lens M25 / M20 / Blanked Xenon D25 / 35 Watt VAC, VAC, 254 VAC at 50/60 Hz or 12 VDC, 24 VDC 50 Watt Approx. 10 kg. Glass X X # # X - - # 254 = 254VAC 230 = 220/240VAC 120 = 110/120VAC 24 = 24VDC 12 = 12VDC E = Explosion Proof, I = Industrial For XCX130: 1 = Ex de with TNCN and 2xØ25 2 = Ex de c/w EEx e bottom 5xØ25 entries 3 = Ex d with 1xM25 bottom entry 4 = Ex d with 1xM25 bottom entry and ying lead (5m) Diameter 130 = 130 mm X = Xenon light source Material types: C = SS316L, A = Aluminium TNX Typical oodlight with connection box or ying lead: XCX1301E-230 XCX1304E-12 TNXCX130 Ex de oodlight SS316L TNXCX130 Ex d oodlight SS316L TNCN connection box and cable bushing Flying lead cable (5m) 2 nos Ex e M25 entries One Ex d M25 entry DxL = 130x423 mm., 230VAC DxL = 130x378mm., 12VDC 46
47 Lighting TNXCX Dimensions Ex de Ex d Flying Lead Mounting bracket SS316L material Ordering code: TPS14007 Canopy for extra protection against glaring (optional) SS316L Material Ordering code: TPS
48 48
49 Lighting TNCLS The TNCLS range of Ex em LED backlights are designed for use to illuminate level gauges in all kinds of industry where an explosive atmosphere may be present. TNCLS offers a long life, low maintenance LED solution to enable the operator to accurately read the level through the gauge glass. Speci cations Material Stainless steel 316L IP Rating IP66 Temperature -20ºC to + 45ºC (T4) Approvals - Atex DNV-2002-OSL-ATEX-0195 Standards EN/IEC: , , Ex-Code Ex em II T4 II 2 G Surface treatment Acidized Earthing M6 inside and outside Cable entry Max. 2xM25 in top and / or bottom, and/or sides Power comsumption Approx. 3VA per module Voltage VAC or 254VAC Frequency Hz Humidity 100% Terminals Minimum 4x2.5 m² Lumination colour Yellow Size-qty. modules Total length (A) mm Light exposure (B) mm Weight kg Size-qty. modules Total length (A) mm Light exposure (B) mm Weight kg Dimensions Several units can be assembles to one column Type key: TNCLS L-X L = Module lendth X = No. of modules Total length: A = L*X Other sizes upon request 49
50 50
51 Plugs and Sockets Flameproof Connector Starline Explosion Proof Connector, Ex d/de, Hard anodic coating 52 51
52 Plugs and Sockets Starline Flameproof Connector BARTEC TECHNOR is an approved distributor and stockist of the Amphenol Starline & Starline Ex range of heavy duty connectors for power, signal and hybrid applications. Typical applications include: Petro-chemical plants. Off-shore oil drilling. Automotive paint booths. Aircraft Refuelling Pits. Pharmaceutical Manufacturing Equipment Speci cations Operating temperature from -20ºC to +40ºC IP68 Hard anodic coating provides high dielectric strength and superior heat/corrosion resistance. High amperage of 1135 Amps at 1000VAC or DC rating available Solder, crimp and pressure terminals available Standards/Requirements ATEX Certi ed for use in Zone 1 IIC hazardous areas Certi cate SIRA03ATEX1101X II 2 GD Ex d IIC T6 Ex de IIC T6 Coupling / mounting Double lead Acme threads provide complete coupling in one turn of the coupling nut, and do not clog under adverse weather conditions. Large wiring space provided in cable housings and conduit tting bodies. Code Logic Starline Ex ## code for grommets used w/type 2 or 4 hardware styles/ A, B or C etc. for Ex d gland sizes Insert con guration Termination Method N for crimp contact/ R for pressure/blank for solder Cable Type Omit if unarmored. -BS or -BSR Ex 13 3 C P N -01 BS Product Series Pre x Hardware style 13 for Male plug/ 15 for Female Inline/ 17 for Female panelmount 18 for Panel Mount Circular Flange 19 for Thru Bulkhead-Dual Mate Receptacle Connector Shell Size (12, 16, 20, 24, 28, C20, C24, C28) Contact Gender P for Male pin/ S for Female Socket Optional Alternate Key Position Example: EX-13-3-C PN Male plug with Ex gland for a cable with 0.95 /24.1mm O.D., 20ea #12/4.0mm male contacts EX SN Female Inline with basketweave grip for a cable with 0.95 /24.1mm O.D., 20ea #12/4.0mm female contacts EX SN Female Panelmount. 20ea #12/4.0mm female contacts EX-13-3-C-16-22PR-BS Male plug with Ex gland for an armored cable with 1.25 /31.75mm O.D. 4ea #4/25.0mm male contacts EX-17-3-C-16-22SR-BS Female Panelmount with cable adapter with an Ex gland for armored cable to match above 52
53 Plugs and Sockets Starline Flameproof Connector Plug with Mechanical Clamp EX Style Dimension Shell A B C D E F G /4 (222.3) 1-3/4 (44.5) 1-1/2 (38.1) 2 (50.8) 15/16 (23.8) 2-3/8 (60.3) N/A /16 (223.8) 1-3/4 (44.5) 2 (50.8) 2-1/16 (52.4) 1-7/16 (36.5) 3 (76.2) N/A /8 (225.4) 1-3/4 (44.5) 2-1/2 (63.5) 2-1/8 (54.0) 1-15/16 (49.2) 3-3/4 (95.3) N/A /16 (227.0) 1-3/4 (44.5) 3 (76.2) 2-3/16 (55.6) 2-7/16 (61.9) 4-1/2 (114.3) N/A 28 9 (228.6) 3 1/16 (77.8) 4 3/16 (106.4) 2 1/4 (57.2) 2-7/8 (73.0) 5-1/8 (130.2) N/A Plug with Ex d Gland EX Style Dimension Shell A B C Gland Thread /16 (154) 3-9/16 (91) 2-1/8 (54) M /16 (205) 3-9/16 (91) 2-5/8 (67) M /16 (205) 3-9/16 (91) 3-1/8 (79) M /16 (205) 3-9/16 (91) 3-5/8 (92) M /16 (205) 3-9/16 (91) 4-1/8 (105) M75 Plug with Kellems Grip EX Style Dimension Shell A B C D E F G /8 (187.3) 1-3/4 (44.5) 1-1/2 (38.1) 1-1/4 (31.8) 15/16 (23.8) 1-1/2 (38.1) 8 (203.2) /8 (187.3) 1-3/4 (44.5) 2 (50.8) 1-1/4 (31.8) 1-7/16 (36.5) 2 (50.8) 10-1/2 (266.7) /8 (187.3) 1-3/4 (44.5) 2-1/2 (63.5) 1-1/4 (31.8) 1-15/16 (49.2) 2-1/2 (63.5) 14-1/2 (368.3) /8 (187.3) 1-3/4 (44.5) 3 (76.2) 1-1/4 (31.8) 2-7/16 (61.9) 3 (76.2) 17-1/2 (444.5) /8 (187.3) 1-3/4 (44.5) 3-1/2 (88.9) 1-1/4 (31.8) 2-7/8 (73.0) 3-1/2 (88.9) 19 (482.6) In-line Receptacle with Mechanical Clamp EX Style Dimension Shell A B C D E F G /4 (222.3) 1-3/4 (44.5) 1-1/2 (38.1) 2 (50.8) 15/16 (23.8) 2-3/8 (60.3) N/A /16 (223.8) 1-3/4 (44.5) 2 (50.8) 2-1/16 (52.4) 1-7/16 (36.5) 3 (76.2) N/A /8 (225.4) 1-3/4 (44.5) 2-1/2 (63.5) 2-1/8 (54.0) 1-15/16 (49.2) 3-3/4 (95.3) N/A /16 (227.0) 1-3/4 (44.5) 3 (76.2) 2-3/16 (55.6) 2-7/16 (61.9) 4-1/2 (114.3) N/A 28 9 (228.6) 1-3/4 (44.5) 3-1/2 (88.9) 2 1/4 (57.2) 2-7/8 (73.0) 5-1/8 (130.2) N/A In-line Receptacle with Ex d Gland EX Style Dimension Shell A B C Gland Thread /8 (143) 1-7/16 (37) 1-1/2 (38) M /8 (194) 1-7/16 (37) 2 (51) M /8 (194) 1-7/16 (37) 2-1/2 (64) M /8 (194) 1-7/16 (37) 3 (76) M /8 (194) 1-7/16 (37) 3-1/2 (89) M75 53
54 54
55 Plugs and Sockets Starline Flameproof Connector In-line Receptacle with Kellems Grip EX Style Dimension Shell A B C D E F G /8 (187.3) 1-3/4 (44.5) 1-1/2 (38.1) 1-1/4 (31.8) 15/16 (23.8) 1-1/2 (38.1) 8 (203.2) /8 (187.3) 1-3/4 (44.5) 2 (50.8) 1-1/4 (31.8) 1-7/16 (36.5) 2 (50.8) 10-1/2 (266.7) /8 (187.3) 1-3/4 (44.5) 2-1/2 (63.5) 1-1/4 (31.8) 1-15/16 (49.2) 2-1/2 (63.5) 14-1/2 (368.3) /8 (187.3) 1-3/4 (44.5) 3 (76.2) 1-1/4 (31.8) 2-7/16 (61.9) 3 (76.2) 17-1/2 (444.5) /8 (187.3) 1-3/4 (44.5) 3-1/2 (88.9) 1-1/4 (31.8) 2-7/8 (73.0) 3-1/2 (88.9) 19 (482.6) Panel Mount Receptacle (Potting Required) EX Style Dimension Shell A B C D E H /4 (120.7) 1-3/4 (44.5) 1-1/2 (38.1) (42) 2-1/4 (57.2) M /4 (120.7) 1-3/4 (44.5) 2 (50.8) (52) 2-5/8 (66.7) M /4 (120.7) 1-3/4 (44.5) 2-1/2 (63.5) (62) 3 (76.2) M /4 (120.7) 1-3/4 (44.5) 3 (76.2) (72) 3-1/2 (88.9) M /4 (120.7) 1-3/4 (44.5) 3-1/2 (88.9) (82) 4 (101.6) M90 Fixed In-line Receptacle with Mechanical clamp EX Style Dimension Shell A B C D E F /4 (222.3) 1-3/4 (44.5) 1-1/2 (38.1) 2 (50.8) 15/16 (23.8) 2-3/8 (60.3) /16 (223.8) 1-3/4 (44.5) 2 (50.8) 2-1/16 (52.4) 1-7/16 (36.5) 3 (76.2) /8 (225.4) 1-3/4 (44.5) 2-1/2 (63.5) 2-1/8 (54.0) 1-15/16 (49.2) 3-3/4 (95.3) /16 (227.0) 1-3/4 (44.5) 3 (76.2) 2-3/16 (55.6) 2-7/16 (61.9) 4-1/2 (114.3) 28 9 (228.6) 1-3/4 (44.5) 3-1/2 (88.9) 2 1/4 (57.2) Fixed In-line Receptacle with Ex d Gland Dimension Shell A B C Gland Thread /8 (143) 1-7/16 (37) 1-1/2 (38) M /8 (194) 1-7/16 (37) 2 (51) M /8 (194) 1-7/16 (37) 1-/12 (64) M /8 (194) 1-7/16 (37) 3 (76) M /8 (194) 1-7/16 (37) 3-1/2 (89) M75 EX Style Fixed In-line Receptable with Kellems Grip EX Style Dimension Shell A B C D E F G /8 (187.3) 1-3/4 (44.5) 1-1/2 (38.1) 1-1/4 (31.8) 15/16 (23.8) 1-1/2 (38.1) 8 (203.2) /8 (187.3) 1-3/4 (44.5) 2 (50.8) 1-1/4 (31.8) 1-7/16 (36.5) 2 (50.8) 10-1/2 (266.7) /8 (187.3) 1-3/4 (44.5) 2-1/2 (63.5) 1-1/4 (31.8) 1-15/16 (49.2) 2-1/2 (63.5) 14-1/2 (368.3) /8 (187.3) 1-3/4 (44.5) 3 (76.2) 1-1/4 (31.8) 2-7/16 (61.9) 3 (76.2) 17-1/2 (444.5) /8 (187.3) 1-3/4 (44.5) 3-1/2 (88.9) 1-1/4 (31.8) 2-7/8 (73.0) 3-1/2 (88.9) 19 (482.6) 55
56 56
57 Gas Detection TN Mobile Gas Detection System, Ex de, Stainless steel 316L 57
58 Gas Detection TN The Mobile Gas Detection System is specially designed as a protection and shutdown system for use in connection with hot work in Ex Zones 1 and 2 within on- and offshore installations. The unit is designed to shut down the connected electrical equipment and give acoustic and visual alarm when gas is detected. Speci cations Material sensor unit Stainless steel 316L Material trolley and electrical equipment Stainless steel 316L Operating temperature -20ºC to +40ºC Approvals ATEX Approved lifting lugs 2 Ex protection control unit Ex de IIC T5 II 2 G Ex protection sensor Ex de IIC T6 II 2 G Sensor cable Radox Tenuis-TW/S EMC Dimension trolley incl. equipment H x W 1275 x 500mm Total weight (control unit) 105 kg Mobility (control unit) Wheeled, lifted PLC OMRON Sensor Simtronics GD10, Other sensors upon request Rated voltage VAC Max. current 16A Frequency 50/60 Hz Gas monitoring 0-100% LEL Level shut down 10% LEL Earth fault monitoring/ shut off 30mA Dimensions Control unit Shutdown unit (separate) 58
59
60 Safe.t Solutions Safe.t Components Safe.t System Safe.t Systems Safe.t Technology Safe.t Seminars Safe Safe.t Solutions Safe.t Components Safe.t System Safe.t Systems Safe.t Technology Safe.t Seminars Saf Safe.t Seminars Safe.t Solutions Safe.t Components Saf UK-D-TEC-02/11-BARTEC WerbeAgentur BARTEC TECHNOR AS Dusavikveien 39 P.O.Box Stavanger Norway Phone: Fax:
Terminal Box. Specifications TNCN
Terminal box The /TNCC range comprises many standard sizes of enclosures manufactured in stainless steel 316L for maximum environmental protection. The main body is manufactured from minimum 1,5 mm sheet
EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL
PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex
HAZARDOUS AREA TECHNICAL GUIDE
Page 1 HAZARDOUS AREA TECHNICAL GUIDE The Redapt Hazardous Area Technical Guide provides an overview for the design and use of equipment used within potentially explosive atmospheres created by gases,
Explosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures
SX 8 The SX range comprises 14 sizes of enclosure manufactured in either stainless steel or mild steel. 11 sizes are available in depths of 140 or 200mm and 8 sizes are available in depths of 140, 200
2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
Making sense of Intrinsic Safety and Intrinsically Safe Tools
Making sense of Intrinsic Safety and Intrinsically Safe Tools What is Intrinsically Safe? Intrinsic safety is a protection standard employed in potentially explosive atmospheres. Devices that are certified
Linear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
Technical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
Ex q Powder Filling. This is a technique primarily used for oil filled switch-gear. The spark is formed under oil and venting is controlled.
Methods of explosion protection for electrical equipment Flammable atmospheres can be ignited by sparks or not surfaces arising from the use of electrical power. Other possible sources of ignition are
Instructions for Safe Use
Instructions for Safe Use (Certification N:o VTT 08 ATEX 029) Thank you for choosing Slam Trans portable transformer for your job site. Purpose of this manual is to provide you all the necessary safety
David O Brien, CMP Products ([email protected])
David O Brien, CMP Products ([email protected]) 1) Main Function of Cable Glands 2) Common Issues with Cable Glands 3) Compliance / Standards, changing times 4) How do we select Cable Glands?
Compact pressure switch Flameproof enclosure Ex d Model PCA
Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring
Technical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
Basics of Explosion Protection
Basics of Explosion Protection INTRODUCTION Understanding Global Explosion Protection Class and Division System Class-Zone System CENELEC Zone System IEC A INTRODUCTION Basics of Explosion Protection Basics
IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel
Explosion protection Description Flameproof enclosures BARTEC B or EJB series are designed to be installed in industrial plants, where potential hazardous atmospheres occur. These areas are either classified
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
SEISMIC VELOCITY TRANSDUCER T1-40
SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute
2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design
.8 Ex-Recess-mounted, ceiling emergency light fittings in compact metal design RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX 50... N 18-36 W (Zone 1,, 1, ) The explosion-protected lighting concept for clean rooms
Control and Distribution Boxes made of Stainless Steel Series 8150
www.stahl.de > Circumferential protection channel prevents water entry > Extended temperature range due to high-quality seal s > Optionally with hinges / cam locks or screw-on cover > Hinge versions with
A good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
Plug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
Terminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.
> Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The
Floodlight Range Installation Guide
SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected
Technical data sheet TDS0070
Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush
Linear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
Guide to enclosures for potentially explosive atmospheres
Guide to enclosures for potentially explosive atmospheres Guide to enclosures for potentially explosive atmospheres The safety of every application, in every environment, thanks to ATEX-certified steel,
distributing & controlling system solutions
distributing & controlling system solutions your safety our reality Users > Oil and gas industry production storage transport > Petrochemical industry > Chemical industry > Pharmaceutical industry > Food
INTERNATIONAL STANDARD
IEC 61892-7 INTERNATIONAL STANDARD Edition 2.0 2007-11 Mobile and fixed offshore units Electrical installations Part 7: Hazardous areas INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XA ICS 47.020.60
Solutions through technology
Solutions through technology Reservations of failure and changes in this catalogue. Print: Gunnarshaug - Rev. B Editing completed January 2009. 1 Technor ElectroTech Group is an international technology
Plug and Socket Devices SolConeX 16 A Series 8570
www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle
Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)
Features Variants options Glass fiber reinforced polyester (GRP) enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 16 enclosure size options Various terminal
3500/93 System Display
3500/93 System Display Bently Nevada* Asset Condition Monitoring Description The 3500/93 System Display is designed to meet the requirements of American Petroleum Institute (API) Standard 670 and provide
Operating Instructions
Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4
ATEX Fans 08/02/2008. Data subject to change without prior notice
ATEX Fans Introduction 1. What is ATEX? 1 2. Zones 1 3. Groups and Categories 2 3.1. Group I 2 3.2. Group II 2 3.2.1. Group II, Category 1 2 3.2.2. Group II, Category 2 3 3.2.3. Group II, Category 3 3
Explosion Proof Combination Signal - 110 db (A) / 5 Joule Series YL60
www.stahl.de Explosion Proof Combination Signal - 110 db (A) / 5 Joule > Omnidirectional high output sounder 110 db (A) / 1 m > 5 Joule xenon strobe > 2 stage alarm, independently selectable 2nd stage
FGM 160 ATEX EC type examination certificate
Document number: 75.120.223 Document title: FGM 160 ATEX EC type examination certificate Scope: EN 60079-0, 1, 7, 11, 26 Additional Information (when applicable) F 2015.06.03 New certificate issue Nemko
Technical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
Technical Data. General specifications Switching element function Rated operating distance s n 4 mm
0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
Operating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
Electrical Equipment in Hazardous Areas: Field Inspections
Electrical Equipment in Hazardous Areas: Field Inspections Bill Rankin Electrical Engineer / Senior Electrical Inspector Abstract Electrical equipment and installations that fall within explosive gas atmospheres
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
Inductive slot sensor
0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Extended temperature range Application Danger! In safety-related applications the sensor must be operated with a qualified
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
Solenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
Flameproof Audible Signal 115 db (A) Series YA90
Clifford Snell www.stahl.de > Max sound output 115 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > 32 selectable tones meeting international regulations > Light
Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
3DLevelScanner II TECHNICAL DATA SHEET
TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
How To Protect An Explosion
The basics of explosion protection preface It is a fact that gases, vapours and mists escape during the production, processing, transportation and storage of flammable substances in the chemical and petrochemical
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
Safety instructions VEGADIS DIS81.CEIA/V****
Safety instructions VEGADIS DIS81.CEIA/V**** CSA 14.2662675 Ex d IIC T6 T1 Gb 0044 Document ID: 48926 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 3 4 Application
Fire Alarm System Accessories
Approved by APPROVED Fire Alarm System Accessories FM Approved* Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer
FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)
FLARE MONITORS Infrared Sensors for Monitoring Smokeless Flares, Pilots, and Flame Intensity FMDS2014 FLARE MONITOR (FM) Monitor smokeless flare combustion efficiency to maximize destruction of hazardous
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,
Session 12 Ex Protection Concepts
Session 12 Ex Protection Concepts Ex Protection Concepts Electrical Electrical Symbol Typical Typical Zones IEC Standard Basic concept of protection IEC EPL Increased safety e Gb 1,2 IEC 60079-7 No arcs,
IECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
B-Series Temperature Switches
FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage-treatment
Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm
Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications
EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES
EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES Gas explosion protection II 2G Ex d IIC T6 Gb (suitable for Zone1 and Zone 2) Dust explosion protection II 2D Ex tb IIIC
8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****
Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** FM 3046039 Class I Div 1, Groups A, B, C and D Class II Div 1, Groups E, F and G; Class III Class I, Zone 0, AEx ia IIC Ga, Ga/Gb, Gb Document ID:
Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)
Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow) Drawing 8c Drawing 9c U391_TA10C_DoP_e_150421 www.hoentzsch.com 1 of 5 Measured
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
99/92/EC (ATEX 137) USE
ATEX DIRECTIVE 99/92/EC (ATEX 137) USE The last few years have seen many changes to the regulations that apply to industry: Directive 94/9/EC (ATEX 95): Products. Directive 98/24/EC: Chemical Agents. Directive
Rosemount 752 FOUNDATION fieldbus Remote Indicator
Product Data Sheet September 2014 00813-0100-4377, Rev DA Rosemount 752 FOUNDATION fieldbus Remote Indicator Two-wire segment powered device Displays up to eight values Link Master Capability Optional
400 Series Buccaneer BUCCANEER POWER. bulgin
bulgin BUCCANEER FOR POWER Contact Retainer Sealing Gasket O Ring Contacts Locking Ring Retaining Nut Panel Body Contacts Contact Carrier O Ring Main Body Cable Gland Collet Gland Nut Sealed to IP68 when
Givare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
Explosion Protected White Paper Series #1: Imaging Challenges in Explosive Environments
Video Systems Explosion Protected White Paper Series Imaging Challenges in Explosive Environments Explosion Protected White Paper Series #1: Imaging Challenges in Explosive Environments Introduction Extraordinary
ACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently
(68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please
Isolating Barriers for our sensors A5S1 in Ex-areas Series D461
D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex
Mureva Assembly surface mounted wiring devices
1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label
Operating Instructions
Operating Instructions Control unit Ex p > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Designated Use...4 5 Technical Data...4 6 Transport, Storage
Mini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
Product Brochure. Certified Mining Motors
Product Brochure Certified Mining Motors Profile Baldor Electric Company (a member of the ABB group) is a world leader in motors for the mining industry. In the continuous (24/7) operation of underground
Worcester DS/DM Series UltraSwitch Switch box
Worcester DS/DM Series UltraSwitch Switch box Features DS/DM Series Ultraswitch Description The DS/DM Series UltraSwich from Flowserve Worcester provides cost efficient, accurate and reliable position
Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS 05.0008 Ex t IIIC T Da, Da/Db, Db IP 66
Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS 05.0008 Ex t IIIC T Da, Da/Db, Db IP 66 0044 37321 Contents 1 Area of applicability 4 2 General information 4 2.1 Zone 20 instruments
Technical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject
98371000 REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 2011 ELKHART BRASS MFG. CO., INC.
81471067 Electric Monitor Motor Control Panel For use with Model 8394059 SPIT-FIRE Monitor Installation, Operation, and Maintenance Instructions FOR ATEX APPLICATIONS 1302 WEST BEARDSLEY AVENUE P.O. BOX
Day / Night IR Color Camera User Manual V2.1.0
Day / Night IR Color Camera User Manual V2.1.0 1 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to DS-2CC102P(N)-IR1(IR3)(IR5),
Scraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D
MT MOTORI ELETTRICI Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D TABLE OF CONTENTS 1. Introduction 2. Scope of application 3. Installation
BULLET. Description. Features. WirelessHART Adapter for Use with Wired HART Field Devices
March 0 Description The enables new and existing wired smart HART fi eld devices, non-smart analog fi eld devices and remote HART I/O from any supplier to communicate with host applications using technology.
Control- and feedback head for integrated mounting on Robolux valves Type 2036
Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated
Threaded Resistance Thermometers Model TR10-D, Miniature Design
Electrical Temperature Measurement Threaded Resistance Thermometers Model TR10-D, Miniature Design WIKA Data Sheet TE 60.04 Applications Machine building, plant and tank construction Power transmission
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
OLI. Oil level indicator
OLI Oil level indicator Oil level indicator Unexpected or accidental oil leakages may occur randomly along transformer s lifetime. Clear indication of oil level inside transformer tank and on load tap
Professional Series ATEX Portable Radios
Systemcom A/S [email protected] +47 900 20 366 Professional Series ATEX Portable Radios Product Launch, July 2005 Professional Series ATEX Objectives Provide our customers with best-in-class