ST 3000 Smart Pressure Transmitter Series 900 Differential Pressure Models. Specification and Model Selection Guide. Introduction 34-ST /19/05
|
|
|
- Willis Mosley
- 9 years ago
- Views:
Transcription
1 ST 3000 Smart Pressure Transmitter Series 900 Differential Pressure Models STD924 0 to 400 inh2o 0 to 1,000 mbar STD930 0 to 100 psi 0 to 7,000 mbar STD974 0 to 3000 psi 0 to 210,000 mbar Introduction 34-ST /19/05 Specification and Model Selection Guide In 1983, Honeywell introduced the first Smart Pressure Transmitter the ST In 1989, Honeywell launched the first all digital, bi-directional protocol for smart field devices. Today, its ST 3000 Series 900 Differential Pressure Transmitters continue to bring proven smart technology to a wide spectrum of pressure measurement applications, from furnace combustion airflow rate to hydrostatic tank gauging. The ST 3000 S900 Differential Pressure Transmitter can be used with any primary flow element to provide proven, repeatable flow measurement. All ST 3000 transmitters can provide a 4-20 ma output, Honeywell Digitally Enhanced (DE) output, HART * output, or FOUNDATION Fieldbus output. When digitally integrated with Honeywell s Process Knowledge System, EXPERION PKS, ST 3000 instruments provide a more accurate process variable as well as advanced diagnostics. Honeywell s cost-effective ST 3000 S900 transmitters lead the industry in reliability and stability: Stability = +/-0.01% per year Reliability = 470 years MTBF Figure 1 Series 900 Differential Pressure Transmitters feature proven piezoresistive sensor technology. The devices provide comprehensive self-diagnostics to help users maintain high uptime, meet regulatory requirements, and attain high quality standards. S900 transmitters allow smart performance at analog prices. Accurate, reliable and stable, Series 900 transmitters offer greater turndown ratio than conventional transmitters. "Honeywell transmitters operating in the digital mode using Honeywell's Digitally Enhanced (DE) protocol make diagnostics available right at the control system's human interface. Equally important, transmitter status information is continuously displayed to alert the operator immediately of a fault condition. Because the process variable (PV) status transmission precedes the PV value, we are guaranteed that a bad PV is not used in a control algorithm. In addition, bi-directional communication provides for remote transmitter configuration directly from the human interface, enabling management of the complete loop. Maureen Atchison, DuPont Site Electrical & Instrumentation Leader
2 Page 2 Description The ST 3000 transmitter can replace any 4 to 20 ma output transmitter in use today and operates over a standard two-wire system. The measuring means is a piezoresistive sensor, which actually contains three sensors in one. It contains a differential pressure sensor, a temperature sensor, and a static pressure sensor. Microprocessor-based electronics provide higher span-turndown ratio, improved temperature and pressure compensation, and improved accuracy. The transmitter s meter body and electronics housing resist shock, vibration, corrosion, and moisture. The electronics housing contains a compartment for the single-board electronics, which is isolated from an integral junction box. The single-board electronics is replaceable and interchangeable with any other ST 3000 Series 100 or Series 900 model transmitter. Like other Honeywell transmitters, the ST 3000 features two-way communication between the operator and the transmitter through our Smart Field Configurator (SFC). You can connect the SFC anywhere that you can access the transmitter signal lines. The SCT 3000 Smartline Configuration Toolkit provides an easy way to configure instruments using a personal computer. The toolkit enables configuration of devices before shipping or installation. The SCT 3000 can operate in the offline mode to configure an unlimited number of devices. The database can then be loaded downline during commissioning. Features Choice of linear or square root output conformity is a simple configuration selection. Direct digital integration with Experion PKS and other control systems provides local measurement accuracy to the system level without adding typical A/D and D/A converter inaccuracies. Unique piezoresistive sensor automatically compensates input for temperature and static pressure.added smart features include configuring lower and upper range values, simulating accurate analog output, and selecting preprogrammed engineering units for display. Smart transmitter capabilities with local or remote interfacing means significant manpower efficiency improvements in commissioning, start-up, and ongoing maintenance functions.
3 Page 3 Specifications Operating Conditions All Models Parameter Reference Condition (at zero static) Rated Condition Operative Limits Transportation and Storage C F C F C F C F Ambient Temperature 25 ±1 77 ±2-40 to to to to to to 257 Meter Body Temperature 25 ±1 77 ±2-40 to 110* -40 to 230* -40 to to to to 257 Humidity %RH 10 to 55 0 to to to 100 Vacuum Region - Minimum Pressure mmhg absolute inh2o absolute Atmospheric Atmospheric (short term **) 1 (short term **) Supply Voltage, Current, and Load Resistance Maximum Allowable Working Pressure (MAWP) (ST 3000 products are rated to Maximum Allowable Working Pressure. MAWP depends on Approval Agency and transmitter materials of construction.) Voltage Range: 10.8 to 42.4 Vdc at terminals Current Range: 3.0 to 21.8 ma Load Resistance: 0 to 1440 ohms (as shown in Figure 2) ***STD924-AXX, BXX, EXX, FXX, JXX = 3000 psi, 210 bar STD924-CXX, DXX, GXX, HXX, KXX, LXX = 4500 psi, 310 bar ***STD930-AXX, BXX, EXX, FXX, JXX = 3000 psi, 210 bar STD930-CXX, DXX, GXX, HXX, KXX, LXX = 4500 psi, 310 bar STD974 = 4500 psi, 310 bar Static Pressure Limit = Maximum Allowable Working Pressure (MAWP) = Overpressure Limit * For CTFE fill fluid, the rating is 15 to 70 C (5 to 158 F). ** Short term equals 2 hours at 70 C (158 F). ***Static Pressure is de-rated to 2000 psi (140 bar) for temperatures below 15 C (5 F). MAWP applies for temperature range 40 to 125 deg. C. However, Static Pressure Limit is de-rated to 3000 psi from 26 deg C. to 40 deg. C. Consult factory for MAWP of ST 3000 transmitters with CSA approval Loop Resistance (ohms) NOTE: A minimum of 250 ohms of loop resistance is necessary to support communications. Loop resistance equals barrier resistance plus wire resistance plus receiver resistance. = Operating Area Operating Voltage (Vdc) Figure 2 Supply voltage and loop resistance chart
4 Page 4 Performance Under Rated Conditions* - Model STD924 (0 to 400 inh 2 O/1000 mbar) Parameter Upper Range Limit Minimum Span inh2o mbar inh2o mbar Turndown Ratio 40 to 1 Description 400 (39.2 F/4 C is standard reference temperature for inh2o range.) Note: Recommended minimum span in square root mode is 20 inh2o (50 mbar). 25 Zero Elevation and Suppression 5 to +100% URL. Accuracy (Reference Includes In Analog Mode: ±0.075% of calibrated span or upper range value (URV), whichever combined effects of linearity, is greater, terminal based. hysteresis, and repeatability) For URV below reference point (25 inh2o), accuracy equals: Accuracy includes residual error 25 inh2o after averaging successive ± readings. span inh2o or ± ( span mbar) In Digital Mode: ±0.0625% of calibrated span or upper range value (URV), For FOUNDATION Fieldbus use whichever is greater, terminal based. Digital Mode specifications. For For URV below reference point (25 inh2o), accuracy equals: HART use Analog Mode specifications. 25 inh2o ± span inh2o or ± ( span mbar) Zero Temperature Effect per In Analog Mode: ±0.1625% of span. 28 C (50 F) For URV below reference point (50 inh2o), effect equals: 50 inh2o ± span inh2o or ± ( span mbar) In Digital Mode: ±0.15% of span. For URV below reference point (50 inh2o), effect equals: 50 inh2o ±0.15 span inh2o or ± ( span mbar) Combined Zero and Span In Analog Mode: ±0.25% of span. Temperature Effect per 28 C For URV below reference point (50 inh2o), effect equals: (50 F) 50 inh2o ± span inh2o or ± ( span mbar) In Digital Mode: ±0.225% of span. For URV below reference point (50 inh2o), effect equals: 50 inh2o ± span inh2o or ± ( span mbar) Zero Static Pressure Effect per ±0.1625% of span psi (70 bar) For URV below reference point (50 inh2o), effect equals: 50 inh2o ± span inh2o or ± ( span mbar) Combined Zero and Span Static ±0.30% of span. Pressure Effect per 1000 psi (70 For URV below reference point (50 inh2o), effect equals: bar) 50 inh2o ± span inh2o or ± ( span mbar) Stability ±0.015% of URL per year * Performance specifications are based on reference conditions of 25 C (77 F), zero (0) static pressure, 10 to 55% RH, and 316L Stainless Steel barrier diaphragm.
5 Performance Under Rated Conditions* - Model STD930 (0 to 100 psi/7000 mbar) Parameter Upper Range Limit Minimum Span psi bar psi bar Turndown Ratio 20 to 1 Zero Elevation and Suppression Accuracy (Reference Includes combined effects of linearity, hysteresis, and repeatability) Zero Temperature Effect per 28 C (50 F) Combined Zero and Span Temperature Effect per 28 C (50 F) Zero Static Pressure Effect per 1000 psi (70 bar) Combined Zero and Span Static Pressure Effect per 1000 psi (70 bar) Stability 5 to +100% URL. Description 34-ST Page 5 In Analog Mode: ±0.075% of calibrated span or upper range value (URV), whichever is greater, terminal based. For URV below reference point (20 psi), accuracy equals: ± ( 20 psi or ± ( 1.4 bar In Digital Mode: ±0.0625% of calibrated span or upper range value (URV), whichever is greater, terminal based. For URV below reference point (20 psi), accuracy equals: ± ( 20 psi or ± ( 1.4 bar In Analog Mode: ±0.1625% of span. For URV below reference point (30 psi), effect equals: ± ( 30 psi or ± ( 2 bar In Digital Mode: ±0.15% of span. For URV below reference point (30 psi), effect equals: ±0.15 ( 30 psi or ±0.15 ( 2 bar In Analog Mode: ±0.25% of span. For URV below reference point (30 psi), effect equals: ± ( 30 psi or ± ( 2 bar In Digital Mode: ±0.225% of span. For URV below reference point (30 psi), effect equals: ± ( 30 psi or ± ( 2 bar ±0.1625% of span. For URV below reference point (30 psi), effect equals: ± ( 30 psi or ± ( 2 bar ±0.30% of span. For URV below reference point (30 psi), effect equals: ± ( 30 psi ±0.04% of URL per year or ± ( 2 bar * Performance specifications are based on reference conditions of 25 C (77 F), zero (0) static pressure, 10 to 55% RH, and 316L Stainless Steel barrier diaphragm.
6 Page 6 Performance Under Rated Conditions* - Model STD974 (0 to 3000 psi/210 bar) Parameter Upper Range Limit Minimum Span psi bar psi bar Turndown Ratio 30 to 1 Zero Elevation and Suppression Accuracy (Reference Includes combined effects of linearity, hysteresis, and repeatability) Accuracy includes residual error after averaging successive readings. For FOUNDATION Fieldbus use Digital Mode specifications. For HART use Analog Mode specifications. Zero Temperature Effect per 28 C (50 F) Combined Zero and Span Temperature Effect per 28 C (50 F) Zero Static Pressure Effect per 1000 psi (70 bar) Combined Zero and Span Static Pressure Effect per 1000 psi (70 bar) 0.6 and +100% URL. Description In Analog Mode: ±0.2% of calibrated span or upper range value (URV), whichever is greater, terminal based. For URV below reference point (300 psi), accuracy equals: ± ( 300 psi or ± ( 21 bar In Digital Mode: ±0.175% of calibrated span or upper range value (URV), whichever is greater, terminal based. For URV below reference point (300 psi), accuracy equals: ± ( 300 psi or ± ( 21 bar In Analog Mode: ±0.2125% of span. For URV below reference point (500 psi), effect equals: ± ( 500 psi or ± ( 35 bar In Digital Mode: ±0.20% of span. For URV below reference point (500 psi), effect equals: ±0.20 ( 500 psi or ±0.20 ( 35 bar In Analog Mode: ±0.325% of span. For URV below reference point (500 psi), effect equals: ± ( 500 psi or ± ( 35 bar In Digital Mode: ±0.30% of span. For URV below reference point (500 psi), effect equals: ± ( 500 psi or ± ( 35 bar ±0.1625% of span. For URV below reference point (500 psi), effect equals: ± ( 500 psi or ± ( 35 bar ±0.30% of span. For URV below reference point (500 psi), effect equals: ± ( 500 psi or ± ( 35 bar Stability ±0.03% of URL per year * Performance specifications are based on reference conditions of 25 C (77 F), zero (0) static pressure, 10 to 55% RH, and 316L Stainless Steel barrier diaphragm.
7 Performance Under Rated Conditions - General for all Models Parameter Output (two-wire) Supply Voltage Effect Damping Time Constant CE Conformity (Europe) Lightning Protection Option (Code LP ) Physical and Approval Bodies Parameter Barrier Diaphragms Material STD924, STD930 STD974 Process Head Material STD924, STD930 STD974 Head Gaskets Meter Body Bolting Optional Adapter Flange and Bolts Mounting Bracket Fill Fluid Electronic Housing Process Connections Wiring Mounting Description Analog 4 to 20 ma or DE digital communications mode. Options available for FOUNDATION Fieldbus and HART protocol % span per volt. Dimensions See Figures 4 and 5. Net Weight Approval Bodies - Hazardous Areas - Canadian Registration Number (CRN) Pressure Equipment Directive (97/23/EC) Adjustable from 0 to 32 seconds digital damping. 89/336/EEC, Electromagnetic Compatibility (EMC) Directive. 34-ST Page 7 Leakage Current: 10 microamps 42.4 VDC, 93 C Impulse Rating: 10/20 µ sec. 5,000 Amps (50 strikes) 10,000 Amps (20 strikes) (rise/decay) 10/1000 µ sec. 250 Amps (1000 strikes) 500 Amps (400 strikes) Description 316L SS, Hastelloy C-276, Monel, Tantalum 316L SS, Hastelloy C SS, Carbon Steel (zinc-plated), Monel, Hastelloy 316 SS, Carbon Steel (zinc-plated), Hastelloy Glass filled PTFE standard for STD924 & STD930 with Monel and Tantalum diaphragm and STD974. Teflon standard otherwise. Viton optional. Carbon Steel (Zinc plated) standard. Options include 316 SS, NACE A286 SS bolts and 304 SS nuts and B7M. Adapter Flange materials include 316 SS, Hastelloy 276 and Monel. Standard adapter flange gasket material is glass filled PTFE (STD924 & STD930 Monel and Tantalum diaphragms, and STD974). Teflon standard otherwise. Viton is optional. Carbon Steel (Zinc-plated) or Stainless Steel angle bracket or Carbon Steel flat bracket available (standard options). Silicone DC 200 oil or CTFE (Chlorotrifluoroethylene) Epoxy-Polyester hybrid paint. Low Copper-Aluminum. Meets NEMA 4X (watertight) and NEMA 7 (explosionproof). Stainless steel optional. 1/4-inch NPT; 1/2-inch NPT with adapter, standard option; DIN. Accepts up to 16 AWG (1.5 mm diameter). Can be mounted in virtually any position using the standard mounting bracket. Bracket is designed to mount on 2-inch (50 mm) vertical or horizontal pipe. See Figure 3. Approximately 9 pounds (4.1 Kg) - Approved as explosion proof and intrinsically safe for use in Class I, Division 1, Groups A, B, C, D locations, and nonincendive for Class I, Division 2, Groups A, B, C, D locations. Approved EEx ia IIC T4, T5, T6 and EEx d IIC T5, T6 per ATEX standards. See attached Model Selection Guide for options. - All ST 3000 model designs, except STG19L, STG99L, STG170, STG180, have been registered in all provinces and territories in Canada and are marked CRN: 0F8914.5C. The ST 3000 pressure transmitters listed in this Specification have no pressurized internal volume or have a pressurized internal volume rated less than 1,000 bar (14,500 psig) and/or have a maximum volume of less than 0.1 liter. Therefore, these transmitters are either; not subject to the essential requirements of the directive 97/23/EC (PED, Annex 1) and shall not have the CE mark, or the manufacturer has the free choice of a module when the CE mark is required for pressures > 200 bar (2,900 psig). NOTE: Pressure transmitters that are part of safety equipment for the protection of piping (systems) or vessel(s) from exceeding allowable pressure limits, (equipment with safety functions in accordance with Pressure Equipment Directive 97/23/EC article 1, 2.1.3), require separate examination.
8 Page 8 Figure 3 Examples of typical mounting positions
9 Page 9 Reference Dimensions: millimeters inches With Smart meter Removal Clearance for All Caps Without meter Without meter Plug Optional external ground Rotational Lock Optional Meters Optional Adapter for 1/2-inch NPT See Detail "A" Detail A High Pressure Connection 1/2-inch NPT Low Pressure Connection 1/2-inch NPT Figure 4 Typical models STD924 and STD930-A, B, E, F, J (SS, Hastelloy C) mounting dimensions for reference.
10 Page 10 Reference Dimensions: millimeters inches With Smart meter Removal Clearance for All Caps Without meter Without meter With Analog meter Plug Optional meters Optional external ground Rotational lock SQ Optional Adapter for 1/2-inch NPT See Detail "A" Plug Detail A High Pressure Connection 1/2-inch NPT Low Pressure Connection 1/2-inch NPT Figure 5 Typical models STD924 and STD930-C, D, G, H, K, L (Monel, Tantalum), and model STD974 mounting dimensions for reference
11 Page 11 Options Ordering Information Mounting Bracket The angle mounting bracket is available in either zinc-plated carbon steel or stainless steel and is suitable for horizontal or vertical mounting on a two inch (50 millimeter) pipe, as well as wall mounting. An optional flat mounting bracket is also available in carbon steel for two inch (50 millimeter) pipe mounting. Indicating Meter (ME and SM Options) Two integral meter options are available. An analog meter (option ME) is available with a 0 to 100% linear scale. The Smart Meter (option SM) provides an LCD display for both analog and digital output and can be configured to display pressure in pre-selected engineering units. Lightning Protection (Option LP) A terminal block is available with circuitry that protects the transmitter from transient surges induced by nearby lightning strikes. HART Protocol Compatibility (Option HC) An optional electronics module is available for the ST 3000 that provides HART Protocol compatibility. Transmitters with the HART Option are compatible with the AMS System. (Contact your AMS Supplier if an upgrade is required.) Indicator Configuration (Option CI) Provides custom configuration of Smart Meters. Tagging (Option TG) Up to 30 characters can be added on the stainless steel nameplate mounted on the transmitter s electronics housing at no extra cost. Note that a separate nameplate on the meter body contains the serial number and body-related data. A stainless steel wired on tag with additional data of up to 4 lines of 28 characters is also available. The number of characters for tagging includes spaces. Transmitter Configuration (Option TC) The factory can configure the transmitter linear/square root extraction, damping time, LRV, URV and mode (analog/digital) and enter an ID tag of up to eight characters and scratchpad information as specified. Custom Calibration and ID in Memory (Option CC) The factory can calibrate any range within the scope of the transmitter s range and enter an ID tag of up to eight characters in the transmitter s memory. FOUNDATION Fieldbus (Option FF) Equips transmitter with FF protocol for use in kbit/s FF networks. See document 34-ST for additional information on ST 3000 Fieldbus transmitters. Contact your nearest Honeywell sales office, or In the U.S.: Honeywell Industrial Automation & Control North Black Canyon Hwy. Phoenix, AZ In Canada: The Honeywell Centre 155 Gordon Baker Rd. North York, Ontario M2H 3N In Latin America: Honeywell Inc. 480 Sawgrass Corporate Parkway, Suite 200 Sunrise, FL (954) In Europe and Africa: Honeywell S. A. Avenue du Bourget Brussels, Belgium In Eastern Europe: Honeywell Praha, s.r.o. Budejovicka Prague 4, Czech Republic In the Middle East: Honeywell Middle East Ltd. Khalifa Street, Sheikh Faisal Building Abu Dhabi, U. A. E. In Asia: Honeywell Asia Pacific Inc. Honeywell Building, 17 Changi Business Park Central 1 Singapore Republic of Singapore In the Pacific: Honeywell Pty Ltd. 5 Thomas Holt Drive North Ryde NSW Australia 2113 (61 2) In Japan: Honeywell K.K Shibaura 1-chrome Minato-ku, Tokyo, Japan Specifications are subject to change without notice. (Note that specifications may differ slightly for transmitters manufactured before October 30, 1995.) Or, visit Honeywell on the World Wide Web at:
12 Page 12 Issue 31 Instructions Select the desired Key Number. The arrow to the right marks the selection available. Make one selection from each table, I and II, using the column below the proper arrow. Select as many Table III options as desired (if no options or approvals are desired, specify 9X). A ( ) denotes unrestricted availability. A letter denotes restricted availability. Restrictions follow Table IV. Key Number I II III (Optional) IV - _ - _ -,, + XXXX KEY NUMBER Selection Availability Span 0-10" to 0-400" H 2 O/0-25 to mbar STD924 Body Rating: 3000 psi (210 bar) 0-5 to psi/ to 0-7 bar STD930 Body Rating: 3000 psi (210 bar) to psi/0-7 to bar STD974 Body Rating: 4500 psi (315 bar) TABLE I - METER BODY Wetted Vent/Drain Process Heads Valves ** Barrier and Plugs Diaphragms Carbon Steel * 316 SS 316L SS A Carbon Steel * 316 SS Hastelloy C B Carbon Steel * 316 SS Monel C Material Carbon Steel * 316 SS Tantalum D of 316 SS 316 SS 316L SS E Construction 316 SS 316 SS Hastelloy C F 316 SS 316 SS Monel G 316 SS 316 SS Tantalum H Hastelloy C Hastelloy C Hastelloy C J Hastelloy C Hastelloy C Tantalum K Monel Monel Monel L Fill Fluid Silicone _ 1 _ CTFE _ 2 _ Process Head 1/4" NPT A Configuration 1/2" NPT with Adapter (on 1/4" NPT Head) H t t t TABLE II No Selection * Carbon Steel heads are zinc-plated. Not recommended for water service due to hydrogen migration. Use Stainless Steel heads. ** Vent/Drains are Teflon coated for lubricity.
13 Page 13 Issue 31 STD9 Availability TABLE III - OPTIONS Selection None 00 Communication Protocols HART Protocol Compatible Electronics HC e e e FOUNDATION Fieldbus Communications FF r r r b Indicating Meter Options Analog Meter (0-100 Even 0-10 Square Root) ME Smart Meter SM b Custom Configuration of Smart Meter CI m m m Local Zero LZ x x x Local Zero and Span ZS s s s b Transmitter Housing & Electronics Options Lightning Protection LP Custom Calibration and I.D. in Memory CC Transmitter Configuration TC Write Protection WP 316 SS Electronics Housing - with M20 Conduit Connections SH n n n 1/2" NPT to M SS Conduit Adapter (BASEEFA EEx d IIC) A1 n n n 1/2" NPT to 3/4" NPT 316 SS Conduit Adapter A2 i i i b Stainless Steel Housing with M20 to 1/2" NPT 316 SS Conduit A3 i i i Adapter (use for FM and CSA Approvals) Stainless Steel Customer Wired-On Tag TG (4 lines, 28 characters per line, customer supplied information) Stainless Steel Customer Wired-On Tag (blank) TB Low Temperature o C Ambient Limit LT End Cap Live Circuit Warning Label in Spanish (only with ATEX 3D) SP a a a End Cap Live Circuit Warning Label in Portuguese (only with ATEX 3D) PG a a a b End Cap Live Circuit Warning Label in Italian (only with ATEX 3D) TL a a a End Cap Live Circuit Warning Label in German (only with ATEX 3D) GE a a a Meter Body Options 316 SS Bolts and 316 SS Nuts for Process Heads SS B7M Bolts and Nuts for Process Heads B7 k k b NACE A286 SS Bolts and 304 SS Nuts for Process Heads CR 316 SS Adapter Flange - 1/2" NPT with CS Bolts S2 c c c 316 SS Adapter Flange - 1/2" NPT with 316 SS Bolts S3 k k c 316 SS Adapter Flange - 1/2" NPT with NACE A286 SS Bolts S4 k k c 316 SS Adapter Flange - 1/2" NPT with B7M Bolts S5 k k c Hastelloy C Adapter Flange - 1/2" NPT with CS Bolts T2 c c c b Hastelloy C Adapter Flange - 1/2" NPT with 316 SS Bolts T3 k k c Monel Adapter Flange - 1/2" NPT with CS Bolts V2 c c c Monel Adapter Flange - 1/2" NPT with 316 SS Bolts V3 k k c 316 SS Blind Adapter Flange with CS Bolts B3 k k c 316 SS Blind Adapter Flange with 316 SS Bolts B4 k k c 316 SS Blind Adapter Flange with NACE A286 SS Bolts B5 k k c 316 SS Blind Adapter Flange with B7M Bolts B6 k k c b Side Vent/Drain (End Vent Drain is standard) SV SS Center Vent Drain and Bushing CV Blind DIN SS Flanges Mounted with NACE Bolts B2 d d Modified DIN Process Heads SS DN w w Viton Process Head Gaskets (adapter gaskets ordered separately) VT z z Viton Adapter Flange Gaskets VF k k Transmitter Mounting Brackets Options Mounting Bracket - Carbon Steel MB Mounting Bracket - SS SB b Flat Mounting Bracket - Carbon Steel FB Services/Certificates/Marine Type Approvals Options User's Manual Paper Copy (Standard, HC, or FF ships accordingly) UM Clean Transmitter for Oxygen or Chlorine Service with Certificate 0X j j j Over-Pressure Leak Test with F3392 Certificate TP Calibration Test Report and Certificate of Conformance (F3399) F1 Certificate of Conformance (F3391) F3 b Table III continued next page
14 Page 14 Issue 31 Availability TABLE III - OPTIONS (continued) Selection Certificate of Origin (F0195) F5 FMEDA (SIL) Certificate F6 NACE Certificate (F0198) F7 o o o Marine Type Approvals (DNV, ABS, BV & LR) MT Warranty Options Additional Warranty - 1 year W1 Additional Warranty - 2 years W2 Additional Warranty - 3 years W3 b Additional Warranty - 4 years W4 Approval Body Approval Type Location or Classification No hazardous location approvals 9X Explosion Proof Class I, Div. 1, Groups A,B,C,D Factory Dust Ignition Proof Class II, III Div. 1, Groups E,F,G Mutual Non-Incendive Class I, Div. 2, Groups A,B,C,D 1C Intrinsically Safe Class I, II, III, Div. 1, Groups A,B,C,D,E,F,G Explosion Proof Class I, Div. 1, Groups B,C,D CSA Dust Ignition Proof Class II, III, Div. 1, Groups E,F,G 2J Intrinsically Safe Class I, II, III, Div. 1, Groups b A,B,C,D,E,F,G SA Intrinsically Safe Ex ia IIC T4 4G (Australia) Non-Sparking Ex n IIC T6 (T4 with SM option) Intrinsically Safe, Ex II 1G EEx ia IIC T4, T5,T6 3S Zone 0/1 Flameproof, Zone 1 Ex II 2G EEx d IIC T5, T6, 3D Enclosure IP 66/67 Non-Sparking, Zone 2 Ex II 3G EEx na, IIC T6 3N ATEX* (Honeywell). Enclosure IP 66/67 Multiple Marking** Ex II 1 G EEx ia IIC T4, T5, T6 Int. Safe, Zone 0/1, or Ex II 2 G EEx d IIC T5, T6 3H Flameproof, Zone 1, or Ex II 3 G EEx na, IIC T6 (Honeywell) Non-Sparking, Zone 2 Enclosure IP 66/67 INMETRO Flameproof, Zone 1 Ex d IIC T5 6D (Brazil) *See ATEX installation requirements in the ST 3000 User's Manual STD9 **The user must determine the type of protection required for installation of the equipment. The user shall then check the box [ ] adjacent to the type of protection used on the equipment certification nameplate. Once a type of protection has been check TABLE IV Factory Identification XXXX
15 Page 15 Issue 31 RESTRICTIONS Restriction Available Only With Not Available With Letter Table Selection Table Selection a III 3D or 3H b Select only one option from this group c I H d I E, F III DN e III 4G g I K, L includes side vent no price add h I C, G, L i III 1C or 2J j I _ 2 _ k I C_H, D_H, G_H, H_H, K_H, L_H m III SM n III 1C, 2J o III CR,S4,B5 r III TC, ME, 4G,3S s III FF, ME t III Select from Table III S2,S3,S4 III S5,T2,T3,V2,V3,B3,B4,B5,B6 w I E _ A, F _ A III SV x III FF, SM y I J, includes side vent, no price add III DN z I B, F, J, 2 III FB Note: See ST-83 for Published Specials with pricing. See ST-89 and User's Manual for part numbers. See ST-OE-9 for OMS Order Entry Information including TC, manuals, certificates, drawings and SPINS. See ST-OD-1 for tagging, ID, Transmitter Configuration (TC) and calibration including factory default values. To request a quotation for a non-published "special", fax RFQ to Marketing Applications.
16 Page 16 This page intentionally blank ST 3000 is a registered trademark of Honeywell International Inc. HART* is a trademark of the Hart Communication Foundation. FOUNDATION is a trademark of the Fieldbus Foundation. Industrial Measurement and Control Honeywell International Inc W. Union Hill Drive Phoenix, Arizona Honeywell International Inc.
SMV 3000 Smart Multivariable Flow Transmitter
SMV 3000 Smart Multivariable Flow Transmitter Measurements and Calculations: Differential Pressure Absolute or Gauge Pressure Process Temperature via 100 ohm Pt. RTD or Type J,K,T or E Thermocouple Mass
APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement
For Gauge And Absolute Pressure Measurement Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate
STX2100. Differential Pressure (Flow) Transmitter. GE Measurement & Control. Models FKC...5. Features
GE Measurement & Control STX2100 Differential Pressure (Flow) Transmitter Models FKC...5 The STX2100 differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge
RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features
GE Measurement & Control Solutions RTX 1000 Series Versatile Transmitters for a World of Pressure GE Measurement & Control Solutions is renowned for the design and manufacture of compact and rugged high
How To Make A Smart Transmitter
For Differential/Gauge/Absolute/High Pressure Measurement Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy
Model 3051 Pressure Transmitter with HART Protocol
Model 3051 Pressure Transmitter with HART Protocol Start Step 1: Mount the Transmitter Step 2: Consider Housing Rotation Step 3: Set the Jumpers Step 4: Connect the Wiring and Power Up Step 5: Configure
SmartLine. STD700 SmartLine Differential Pressure Specification 34-ST-03-101. Technical Information. Introduction
SmartLine Technical Information STD700 SmartLine Differential Pressure Specification 34-ST-03-101 Introduction Part of the SmartLine family of products, the STD700 is suitable for monitoring, control and
Wireless Gauge and Absolute Pressure Transmitters Series XYR 5000, Model WG5xx/WA5xx Specifications - Americas
Wireless Gauge and Absolute Pressure Transmitters Series XYR 5000, Model WG5xx/WA5xx Specifications - Americas 34-XY-03-01, May 2012 Function The WG/A5xx is part of the XYR 5000 family of wireless products.
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products
Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
Rosemount 751 Field Signal Indicator
Rosemount 751 Field Signal Indicator Product Data Sheet August 2014 00813-0100-4378, Rev FA Available with an LCD display or analog meter Compact, rugged, and designed for industrial environments Available
Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
Rosemount 752 FOUNDATION fieldbus Remote Indicator
Product Data Sheet September 2014 00813-0100-4377, Rev DA Rosemount 752 FOUNDATION fieldbus Remote Indicator Two-wire segment powered device Displays up to eight values Link Master Capability Optional
Rosemount 333 HART Tri-Loop
Product Data Sheet Rosemount 333 Rosemount 333 HART Tri-Loop HART-TO-ANALOG SIGNAL CONVERTER Convert a digital HART signal into three additional analog signals Easy to configure and install Accessory product
Compact pressure switch Flameproof enclosure Ex d Model PCA
Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring
Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS
EPP - 1 DECRIPTION The odel 575 is used in general water/wastewater applications. The transmitter is offered in a standard non-clogging snub nose end, flush diaphragm or protected flush diaphragm with
Rosemount 333 HART Tri-Loop
Product Data Sheet September 2014 00813-0100-4754, Rev GA Rosemount 333 HART Tri-Loop HART-to-Analog Signal Converter Convert a digital HART signal into three additional analog signals Easy to configure
PRODUCT PROFILE FEATURES
PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER
Micro Motion Model D and DL Coriolis Flow and Density Meters
Product Data Sheet PS-00388, Rev. F April 2013 Micro Motion Model D and DL Coriolis Flow and Density Meters Micro Motion Model D and DL sensors provide flow and density measurement for liquids, gases,
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters
Data Sheet Brooks Digital MFC's & MFM's Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters GENERAL FEATURES Wide FS flow range for measurement
Technical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA
Mobrey Ultrasonic MSP900SH Level and MSP900FH Flow Transmitters Product Data Sheet February 2015 IP2032, Rev BA Non-contacting measurement with no moving parts Fast and simple to install and configure
SITRANS F flowmeters SITRANS F M
Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update
Instruction Manual. T3111 T3111L T3111P T3111Ex
www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs
UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.
GE Measurement & Control UNIK 5800/5900 Flameproof/Explosion-Proof Pressure Sensing Platform The 5800 and 5900 are compact and rugged versions of the high performance UNIK 5000 pressure sensing platform
Rosemount 1199 Submersible Seal
Product Data Sheet July 2013 00813-0400-4016, Rev AA The Rosemount Submersible Seal design uses innovative DP level technology to measure level for top-down applications. For this design, the seal and
2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.
and Transmitter All-in-one package for open channel flow measurement. 3.1 NEW Class 1, Division 1 Approved Sensor As our products are continuously improved, we reserve the right to make any change in the
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
Scraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
In-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS
BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS INTRODUCTION Rupture discs are often used as primary pressure relief devices and to isolate pressure relief valves. When used as a primary pressure relief
Differential Pressure Transmitter Model DPT-10
Electronic Pressure Measurement Differential Pressure Transmitter Model DPT-10 WIKA Data Sheet PE 86.21 Applications Process engineering Pharmaceutical Food and beverage industries Special features High
Electronic Flow Switches
Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power
.55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard
Thermatel Model TA1 Mass Flow Transmitter
Thermatel Model TA1 Mass Flow Transmitter D E S C R I P T I O N Thermatel Thermal Mass Flow Transmitter, Model TA1, provides a high level of performance in mass flow measurement of air and gases. Powerful
For Multi-Parameter Meters see mvx
BULLETIN BULLETIN EM20607 VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up
B-Series Switches Pressure, Differential Pressure & Hydraulic
FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage-treatment
Rosemount 3095 MultiVariable Transmitter with MODBUS Protocol ProductDiscontinued
Product Data Sheet December 2012 00813-0100-4738, Rev JB Rosemount 3095 MultiVariable Transmitter with MODBUS Protocol ProductDiscontinued The Proven Leader in MultiVariable Measurement Industry leading
Microcor Wireless Transmitter (MWT)
Rohrback Cosasco Systems, Inc. Microcor Wireless Transmitter (MWT) Features: Highly Secure and Reliable Self Organizing Wireless Mesh Network High Resolution Metal Loss Measurement for all process environments
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
Fisher 846 Electro-Pneumatic Transducer
846 Transducer Product Bulletin Fisher 846 Electro-Pneumatic Transducer The Fisher 846 electro-pneumatic transducer is a rugged, field-mountable transducer that accepts an electrical input signal and converts
Rosemount 1199 Submersible Seal
Product Data Sheet January 2015 00813-0400-4016, Rev BB The Rosemount Submersible Seal design uses innovative DP Level technology to measure level for top-down applications. For this design, the seal and
Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]
Bulletin P-DM-1100 Series DM-1000 DigiMag Digital Differential Pressure Gage Specifications - Installation and Operating Instructions PRESSURE CONNECTIONS 21/64 [8.59] LONG Ø5 [127.00] 4-31/64 [113.89]
Submersion/Insertion Toroidal Sensor
Instruction Sheet PN 51A-228/rev.P December 2010 Model 228 Submersion/Insertion Toroidal Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION SENSOR/PROCESS
DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly
DREXELBROOK A Leader In Level Measurement Solutions USonic-R Series Ultrasonic Level Measurement System User Friendly Set the measurement range directly in inches, feet, millimeters, centimeters, or meters
DC1000 Series General Purpose UNIVERSAL DIGITAL CONTROLLERS
DC1000 Series General Purpose UNIVESA DIGITA CONTOES PODUCT SPECIFICATION SHEET OVEVIEW The DC1000 family of microprocessor based controllers combine a high degree of functionality, reliability at a very
3DLevelScanner II TECHNICAL DATA SHEET
TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
Rosemount 2088 Absolute and Gage Pressure Transmitter
Product Data Sheet Rosemount 2088 Rosemount 2088 Absolute and Gage Pressure Transmitter Performance of 0.075% with High Accuracy option Lightweight, compact design for cost effective installation Protocols
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
Micro Motion 3098 Gas Specific Gravity Meter
Product Data Sheet PS-001161, Rev. D April 2013 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.
Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020
Field proven rugged construction High overpressure capability High reliability for demanding environments Application specific customization Excellent media compatibility Shock and vibration resistant
Rosemount DP Level Transmitters and 1199 Diaphragm Seal System
Rosemount DP Level Transmitters and 1199 Diaphragm Seal System Product Data Sheet May 2016 00813-0100-4016, Rev RA Applications Level, flow, pressure, interface, density Extreme hot and cold temperatures
PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features
Features Applications The PMP 4000 Series provides a complete range of high level voltage output pressure transducers offering advanced levels of measurement accuracy, stability and flexibility from a
PIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
RPS 8000. High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:
GE Measurement & Control Solutions RPS 8000 High Accuracy Resonant Pressure Sensor For over 35 years, Druck has manufactured precision pressure sensors with a capability to meet critical applications in
Triple Waveband Infra-Red Flame Detection
Minerva S200PLUS Ex ia Intrinsically Safe & Ex d Flameproof Solar Blind Flame Detectors Triple Waveband Infra-Red Flame Detection Key Features Unrivalled black body rejection over a wide range of source
FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)
FLARE MONITORS Infrared Sensors for Monitoring Smokeless Flares, Pilots, and Flame Intensity FMDS2014 FLARE MONITOR (FM) Monitor smokeless flare combustion efficiency to maximize destruction of hazardous
BULLET. Description. Features. WirelessHART Adapter for Use with Wired HART Field Devices
March 0 Description The enables new and existing wired smart HART fi eld devices, non-smart analog fi eld devices and remote HART I/O from any supplier to communicate with host applications using technology.
OPTIMASS 1400 Technical Datasheet
OPTIMASS 1400 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only
TEIP11 I/P signal converter for standard signals. Measurement made easy
Data Sheet 10/18-0.11-EN Rev. B TEIP11 I/P signal converter for standard signals Measurement made easy Current in air pressure Proven and reliable concept Compact design Small dimensions, low weight Sturdy
4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
The Unique Accelabar Flow Meter
The Unique Accelabar Flow Meter The Accelabar is a new and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter.
Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter
3710 and 3720 Positioners Product Bulletin Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter Fisher 3710 pneumatic and 3720 electro-pneumatic positioners are designed for use with either
OPTIMASS 6000 Technical Datasheet
OPTIMASS 6000 Technical Datasheet Sensor for mass flow The high performance meter for process industries Cryogenic, high temperature and high pressure options Supreme liquid and gas performance with CT
API Flanged Safety Relief Valves Series 526 CATALOG
API Flanged Safety Relief Valves Series 26 CATALOG The-Safety-Valve.com 1 Valve finder How to find the right product group High operating to set pressure ratio, high backpressure or low total height? Yes
Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Transmitters and Alarms
Data Sheet Models MT 3809 & 3819 Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Transmitters and Alarms Broad range of flow capacities 2% Full scale accuracy Versatile
S-series SQ Controller
DeltaV Distributed Control System Product Data Sheet December 2015 S-series SQ Controller Scalable controllers Quick assembly Easy-to-use Field proven architecture Designed for Electonic Marshalling Advanced
COMBIMASS. Technical Data COMBIMASS eco-bio +
COMBIMASS Technical Data THE SYSTEM COMBIMASS The field transmitters of the COMBIMASS eco series are suitable for gas flow measurement and cover a wide range of different applications. The instruments
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Model 266MST Differential Model 266RST Absolute. Measurement made easy. 2600T series pressure transmitters. Engineered solutions for all applications
Data Sheet DS/266MST/RST-EN Rev. D Model 266MST Differential Model 266RST Absolute Measurement made easy 2600T series pressure transmitters Engineered solutions for all applications Base accuracy 0.04
Flow switches Series AD/VH
Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,
Sanitary Type Electronic Flow Switches
Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts
key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100
Pointek CLS 100 Compact design and short insertion length. Ideal for constricted spaces and for small vessels or pipes up to 100 mm (4 ). Tecum cuil Ludere ipsae. Possem Precision level detection When
Technical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex
Data Sheet 0/-8.5 EN FieldIT Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit)
Toroidal Conductivity Sensor
Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:
Pressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
Rosemount 3051 Pressure Transmitter
Rosemount 3051 Pressure Transmitter with HART Protocol Reference Manual www.emersonprocess.com/rosemount Reference Manual Title Page Rosemount 3051 Pressure Transmitter Read this manual before working
Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)
Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow) Drawing 8c Drawing 9c U391_TA10C_DoP_e_150421 www.hoentzsch.com 1 of 5 Measured
Models SFP33 & SFP32 Pressure Transmitters
SFP33 Flow-Through Pressure Transmitter SFP32 Single-Ended Pressure Transmitter DS-PR-SFP-eng April, 2016 Data Sheet Models SFP33 & SFP32 Pressure Transmitters Pressure Brooks Seal Free Pressure Measurement
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL
PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex
Model 261GS for gauge pressure Model 261AS for absolute pressure
Data Sheet SS/261GS/AS-EN Rev. 07 Model 261GS for gauge pressure Model 261AS for absolute pressure 2600T series pressure transmitters Engineered solutions for all applications Measurement made easy Standard
1701/22 FieldMonitor Management Interface Module
1701/22 FieldMonitor Management Interface Module Bently Nevada Asset Condition Monitoring Description The 1701/22 FieldMonitor Management Interface Module (FMIM) is a highlyintegrated module that provides
Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.
Dimensions LUC-M20 with F12 housing and process connection 2" approx. 86 65 78 Ø129 150 AF60 85 G2 2 NPT 22 ~148 Ø50 ~83 Additional dimensions see section dimensions. Features Quick and simple commissioning
BLUE RIBBON CORP. BC001 Birdcage Installation Manual
Product Overview: This manual is applicable for the BC001 Birdcage Submersible Level Transmitters. If the product you have has a different prefix part number than listed above please contact the factory
T0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction
Manual Supplement Rosemount 5300 and 5400 Series Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction Introduction..................................... page S-1 Safety Messages.................................
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,
Tyco PremiAir Pneumatic Actuators
A comprehensive range of pneumatic actuators, conforming to EN ISO 5211, providing compact, reliable and economical powered operation for all types of quarter turn valves. Features Mounting to valve either
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
Electronic Pressure Switch EDS 3000
For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
Typical Aluminum GFM Mass Flow Meter
MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.