1 COMPUTED MEDICAL IMAGING Nobel Lecture, 8 December, 1979 BY GODFREY N. HOUNSFIELD The Medical Systems Department of Central Research Laboratories EMI, London, England In preparing this paper I realised that I would be speaking to a general audience and have therefore included a description of computed tomography (CT) and some of my early experiments that led up to the development of the new technique. I have concluded with an overall picture of the CT scene and of projected developments in both CT and other types of systems, such as Nuclear Magnetic Resonance (NMR). Although it is barely 8 years since the first brain scanner was constructed, computed tomography is now relatively widely used and has been extensively demonstrated. At the present time this new system is operating in some 1000 hospitals throughout the world. The technique has succe ssfully overcome many of the limitations which are inherent in conventional X- ray technology. When we consider the capabilities of conventional X-ray methods, three main limitations become obvious. Firstly, it is impossible to display within the framework of a two-dimensional X-ray picture all the information contained in the three-dimensional scene under view. Objects situated in depth, i. e. in the third dimension, superimpose, causing confusion to the viewer. Secondly, conventional X-rays cannot distinguish between soft tissues. In general, a radiogram differentiates only between bone and air, as in the lungs. Variations in soft tissues such as the liver and pancreas are not discernible at all and certain other organs may be rendered visible only through the use of radio-opaque dyes. Thirdly, when conventional X-ray methods are used, it is not possible to measure in a quantitative way the separate densities of the individual substances through which the X-ray has passed. The radiogram records the mean absorption by all the various tissues which the X-ray has penetrated. This is of little use for quantitative measurement. Computed tomography, on the other hand, measures the attenuation of X-ray beams passing through sections of the body from hundreds of different angles, and then, from the evidence of these measurements, a computer is able to reconstruct pictures of the body s interior. Pictures are based on the separate examination of a series of contiguous cross sections, as though we looked at the body separated into a series of thin slices. By doing so, we virtually obtain total three-dimensional information about the body. 568
2 Fig. 1. CT scan taken through the kidneys However, the technique s most important feature is its enormously greater sensitivity. It allows soft tissue such as the liver and kidneys to be clearly differentiated, which radiographs cannot do. An example is shown in Fig. 1. It can also very accurately measure the values of X-ray absorption of tissues, thus enabling the nature of tissue to be studied. These capabilities are of great benefit in the diagnosis of disease, but CT additionally plays a role in the field of therapy by accurately locating, for example, a tumour so indicating the areas of the body to be irradiated and by monitorig the progress of the treatment afterwards. It may be of interest if I describe some of the early experiments that led up to the development of CT. Some time ago I investigated the possibility that a computer might be able to reconstruct a picture from sets of very accurate X-ray measurements taken through the body at a multitude of different angles. Many hundreds of thousands of measurements would have to be taken, and reconstructing a picture from them seemed to be a mammoth task as it appeared at the time that it would require an equal number of many hundreds of thousands of simultaneous equations to be solved. When I investigated the advantages over conventional X-ray techniques however, it became apparent that the conventional methods were not making full use of all the information the X-rays could give. On the other hand, calculations showed that the new system used the data very efficiently and would be two orders of magnitude more sensitive than conventional X-rays. For this reason I hoped that it would be possible to distinguish between the various tissues of the body, although I could not find any literature which suggested that such X-ray absorption differences existed.
3 570 Physiology or Medicine 1979 THE EARLY TEST S I decided to do some lab experiments with gamma rays to test if the system would work. The equipment was very much improvised. A lathe bed provided the lateral scanning movement of the gamma-ray source, and sensitive detectors were placed on either side of the object to be viewed which was rotated 1 at the end of each sweep. The 28,000 measurements from the detector were digitized and automatically recorded on paper tape. After the scan had been completed this was fed into the computer and processed. Many tests were made on this machine, and the pictures were encouraging despite the fact that the machine worked extremely slowly, taking 9 days to scan the object because of the low intensity gamma source. The pictures took 2 1 hours to be processed on a large computer. The results of the processing were received on paper tape and these were brought to the laboratory and caused to modulate a spot of light on a cathode ray tube point by point, in front of a camera. As paper tape was used this was a slow process and it took at best two hours to produce a photograph. Clearly, nine days for a picture was too time-consuming, and the gamma source was replaced by a more powerful X-ray tube source, which reduced the scanning time to nine hours (Fig. 2). From then on, much better pictures were obtained; these were usually of blocks of perspex. A preserved specimen of a human brain was eventually provided by a local hospital museum and we produced the first picture of a brain to show grey and white matter (Fig. 3). Fig. 2. Laboratory machine, showing X-ray tube and detector traversing along a lathe bed across a human brain. At the end of the stroke the brain would be rotated 1 and the traverse would be repeated.
4 571 Fig. 3. Picture of the first brain scanned on Laboratory machine Fig. 2. Disappointingly, further analyses revealed that the formalin used to preserve the specimen had enhanced the readings, and had produced exaggerated results. Fresh bullock s brains were therefore used to crosscheck the experiments, and although the variations in tissue density were less pronounced, it was confirmed that a large amount of anatomic detail could be seen. In parallel, tests were carried out on sections through pigs Fig. 4. First clinical prototype brain scanner installed at Atkinson Morley s Hospital, London.
5 572 Physiology or Medicine 1979 in the area of the kidneys, and this work also produced most encouraging results. Although the speed had been increased to one picture per day, we had a little trouble with the specimen decaying while the picture was being taken, so producing gas bubbles, which increased in size as the scanning proceeded. At this point in time, we found that we could see brain and body tissues clearly but we were still very worried as to whether tumours would show up at all. Unless it could do this, the machine would be of very little use. To test this, we had to build a much faster and more sophisticated machine that would scan the brains of living patients in a hospital (Fig. 4). In 1972 the first patient was scanned by this machine. She was a woman who had a suspected brain lesion, and the picture showed clearly in detail a dark circular cyst in the brain (Fig. 5). From this moment on, as more patients were being scanned, it became evident that the machine was going to be sensitive enough to distinguish the difference between normal and diseased tissue. Fig. 5. First clinical picture obtained from prototype machine. Applying the principles to scanning the body seemed to be the next logical step, a larger and faster scanner was designed capable of taking high resolution pictures of the body in 18 seconds. Fig. 1 is a typical picture taken by this machine. Since then, there has been a tendency to construct more complicated machined with a scan time of 3 seconds or less (Fig. 6).
6 Fig. 6. A machine capable of scanning at a rate of 3 sec/picture. PRINCIPLES OF THE TECHNIQUE There are three types of CT machine currently in use (Fig. 7). Basically all three systems use different methods of scanning the patient but end up by taking approximately the same pattern of readings, namely sets of readings across the patient either as parallel sets or into the form of a fan. These are taken at a multitude of different angles (Fig. 8). The system shown in Fig. 7a, translates across the body, each detector taking parallel sets of readings, at the same time as it rotates around the body. It could have 30 detectors and take 18 seconds to scan a picture. In the second system (Fig. 7b) the sets of readings taken are in the form of a fan. It does not translate across the body but only rotates around it. This system usually has approximately detectors but is faster and can take a picture in three seconds. The detectors in this picture have to be accurately stabilised. In the third system (Fig. 7c) the detectors are assembled in a fixed circle and only the X-ray tube sweeps around the body, taking a fan of readings as it does so. This system requires detectors and it also
7 574 Physiology or Medicine 1979 Translate rotate Rotate only Stationary circular detector array Fig. 7. Three different methods of scanning the patient. takes a picture in three seconds. It is not necessary to stabilise detectors in this case. The whole effect of this motion is to take approximately one million accurate absorption measurements through the body in the form of a number of sweeps across (or projections through) the body. These are taken at all angles through the slice, thus providing us with an enormous amount of information about the composition of the slice (Fig. 8). The
8 readings from the detectors are fed into a computer which derives the absorption of the material in the path of the X-ray beam. Absorption = log Intensity X-rays Detector reading The absorption coefficients of the various substances within each square millimetre of the slice can be reconstructed from the readings (i.e. from approximately 1000 back projections each of some 500 readings). They can be displayed as grey tones on a picture or printed out to an accuracy of approx. 1/4 % with respect to water. Originally the method of picture reconstruction, I like to think, was attained by common-sense practical steps. Most of the available mathematical methods at the time were of an idealised nature and rather impractical. FACTORS WHICH GOVERN THE IMPROVED SENSITIVITY O THE SYSTE M F Many will be aware of the conventional tomogram which also images a slice through the body. This is achieved by blurring the image of the material on the picture either side of the slice, by moving both the X-ray tube and photographic plate in opposite directions while the picture is being taken. If one makes a comparison of CT with conventional tomography (Fig. 9a) it is clear that in the latter only a short path of the beam (1/10th of its length AR) passes through the slice to be viewed, collecting useful information. The other 9/10ths of the beam pass through material on either side of the slice, collecting unwanted information which will produce artefacts on the picture. Referring to Fig. 9b in computed tomography, the X-ray beam passes along the full length of the plane of the slice via its edges, and thus the measurements taken by it was 100 % relevant to that slice and that slice alone. They are not affected by the materials lying on either side of the section. The material inside the CT slice is seen as a mesh of variables, which is intersected by all the beam paths at a multitude of different angles (Fig. 10). As the absorption measured by each beam path is the sum of all the mesh squares it passes through, the solution of the mesh variables is possible. If the X-ray beam is confined to the slice and there are no external variables, the entire information potential of the X-ray beam is therefore used to the full.
9 576 Fig. 9. Illustrating the improved efficiency of information collection when conventional tomography and CT are compared. Note that in the case of CT the X-ray beam passes through only the material required to be viewed
10 ACCURACY The scale shown (Fig. 11) demonstrates the accuracy to which the absorption values can be ascertained on the picture. It shows the whole range of the machine, from air (-1000) at the bottom of the scale, to bone at the top of the scale, covering some levels of absorption either side of water, which has been chosen to be zero at the centre. (This is done for convenience, as the absorption of water is close to that of tissue). To obtain readings which relate to true absorption, 1000 must be added to these readings, making air zero, and water would then be The range of tones between black and white seen on the picture can be restricted to a very small part of the scale. This window can be raised or lowered according to the absorption value of the material we wish to compare: for example, it must be raised to see the tissue of the heart or lowered to see detail within the air of the lung. The sensitivity can be increased by reducing the window width, where the absorption difference between the liver and other organs can be more clearly differentiated. Let us now consider to what accuracy one can ascertain the absorption values of CT pictures. The clarity of the picture (Fig. 1), and hence the accuracy to which one can measure absorption values, is impaired by a Fig. 11. Demonstrating the accuracy to which absorption values can be ascertained on the CT picture.
11 578 Physiology or Medicine 1979 mottled appearance (or grain) which unfortunately is fundamental to the system. It is caused by there being a limited number of photons arriving at the detectors after penetrating the body. This results in a statistical spread between readings and is a situation that must be accepted. A typical spread would be a standard deviation of 1/2 % on tissue. (Displayed on a 320x320 matrix). Present CT methods use very nearly all the available photon information that can be extracted from the X-ray beam, and we must therefore deduce that there is little room for further improvement in grain reduction. However, for industrial uses there are no X-ray dose constraints to be considered. The improvements to picture grain would be proportional to dose for a particular picture resolution. THE RELATIONSHIP BETWEEN RESOLUTION AND PICTUR NOISE (OR GRAIN) E The study of picture noise reveals a rather important fact. The picture noise concentrates mainly at the high frequencies, there being very little noise at the lower frequencies. In other words, if we reduce the resolution of the picture by filtering out the higher frequency components, the remaining low frequencies will then be very small in amplitude, enabling the sensitivity of the machine to be increased without undue noise appearing on the picture. There is therefore a trade off between noise and resolution. Noise 00 (resolution) 3/2 During the development of the whole-body CT scanner, it became clear that the availability of an accurate cross-sectional picture of the body, the CT slice, would have an important effect on the precision and implementation of radiotherapy treatment planning. For many years had existed an imbalance in the degree of precision of various aspects of the chain of events which make up a course of treatment by radiation therapy. For example, the linear accelerator, now regarded as the preferred treatment equipment for radical radiotherapy, can deliver X-ray beams with a precision of approximately ± 1.00 mm in terms of spatial aiming. It can also achieve accuracies of the order of 1% in most of the other essential parameters of its operation. CT provides us with accurate measurements for aligning these beams. In the past, radiation treatment planning has been a very lengthy procedure. Now with the aid of CT therapy planning computer programs, we can position the therapy beams automatically with precision in a few minutes. The system is linked to a CT diagnostic display console and a colour display monitor which shows the radiation isodose distributions overlaid on the basic CT scan itself (Fig. 12). The scan is used as the patient input to the system and areas of interest such as tumour, bone, lung or sensitive organs are outlined by an interactive light-pen.
12 Fig. 12. Computer calculated isodose contours for therapy treatment. Radiation beams and their computed isodose contours appear as overlays on the colour screen, and the lines of dose level are given different colours to aid the assessment of the plan. The system uses the CT density numbers for the calculation of the effect of inhomogeneities in the path of radiation beams, although the absorption coefficients have to be corrected for the X-ray energy to be used in the actual treatment. After areas to be irradiated and those to be avoided (such as the spine) have been outlined by means of a light pen, the position of the beam (shown Fig. 12 as T-shaped lines) can either be rotated around the tumour by means of the same light pen or the optimum position of the beams can be chosen automatically by program. This takes into account the CT numbers on the picture, the size and position of the tumour and the areas outlined by the operator which needs to be avoided. It automatically adjusts position and strength of the beams in order to choose the optimum contour of irradiation across the body. Fig. 13 shows a series of pictures demonstrating the regression of a seminoma (a very radio-sensitive tumour). The radiation is applied at a low level while the tumour is large, but as the lesion regresses the smaller area is taken advantage of and larger doses are then applied. In this particular case the tumour was completely removed by accurate intense radiation. These are, however, early days in the applications of CT to radiotherapy planning. It remains to be seen whether the increase in precision really results in a better five-year survival rate. In the opinion of many leading oncologists, evidence already points to such improvements, but it will be the next five years which provide the answers to these questions.
13 Fig. 13. Demonstrating the regression of a seminoma after four stages of therapy treatment. WHAT IMPROVEMENTS SHOULD WE EXPECT TO SEE IN TH FUTURE? E Various attempts have been made to achieve useful pictures of the heart. The time available for taking a picture of the heart is obviously longer than one heart beat. Some experiments were conducted some time ago using conventional CT machines but in which the traverse of the detectors was synchronised to the heart beat via an electro-cargiograph, passing over the heart in diastole (when the heart movement is at a minimum). Fig. 14 shows a picture from the experiment. The heart chambers can be discerned by a little intravenous injected contrast media. Another approach is being made at the Mayo clinic, Rochester, America, where a large machine is being constructed with 27 X-ray tubes designed to fire sequentially. It is hoped to take a sequence of pictures in a fraction of a second during one heart beat. However, the complexity and cost may rule out such a machine being used world-wide. A further promising field may be the detection of the coronary arteries. It may be possible to detect these under special conditions of scanning. Fig. 15 is an example of present high resolution CT scans of the spine using contrast media. It is more than likely that machines in the future will
14 581 Fig. 14. Scanning of the heart with detectors synchronised to the heart-beat passing over the heart in diastole. (The line artefacts are streaks caused by the wire of a pace-maker). be designed to provide considerably higher resolution than shown in this picture. Such machines would take up many of the present uses of conventional radiography but would do the job considerably better. They would have the added bonus of having more sensitive detectors than does film. As all the information on the body is stored in three dimensions, it is possible therefore to display the object at any angle; this allows it to be examined by rotating it around on the screen. The views seen around the organ to be examined may reveal information that hitherto could have been missed, when it was viewed normally in one fixed plane, normal to the axis of the body. Fig. 15 Higher resolution picture of the base of the skull.
15 NMR IMAGING So far, it has been demonstrated that a picture can be reconstructed from X-ray sweeps forming sets of line integrals taken through the body at a multitude of different angles. However, there are methods other than those using X-rays which are capable of measuring tissue variation, such as the use of protons, neutrons or nuclear magnetic resonance. These can be caused to generate sets of measurements of line integrals at different angles across the body, and in a similar manner a picture can be reconstructed from them. Fig. 16 shows what is believed to be the first picture taken of a human head using Nuclear Magnetic Resonance. It was taken in 1978 by a team led by Dr. Hugh Clow and Dr. Ian Young of EMI Central Research Laboratories, England. Since then considerable improvements have been made to both head and body pictures and progress is continuing. The principle of NMR Spectroscopy was well known in the 1960 s and was first suggested for imaging by Lauterbur in It is a new and quite different form of imaging, in which the radio frequencies emitted by the hydrogen nucleus can be measured after they have been excited in a particular way by radio frequency. The nucleus of special interest is the proton of water molecules within the body. I would now like to compare the merits of CT with those of NMR. Before doing this I must first describe the principles on which NMR operates. When hydrogen protons are placed in a magnetic field they will precess (or wobble ) around the field direction just as a spinning top precesses around its vertical gravitational field. This precession occurs at a definite frequency, known as the Larmor frequency, and is proportional to the magnetic field intensity. Fig. 16. Picture taken in 1978 of the human head using Nuclear Magnetic Resonance.
16 The usual NMR procedure for imaging is to apply a strong magnetic field along the body to be studied. (Figs. 17a & 17b). After a short period of time, the nuclei will align with their magnetic movements along the held. A radio frequency tuned to the precession frequency of the hydrogen nucleus is then applied at right angles to the main field by means of a set of coils at the side of the body (Fig. 17c). This causes some of the hydrogen nuclei to precess-all keeping in step. After the radio frequency field has been switched off, the nuclei will continue to precess in phase, generating a similar radio frequency which can be picked up in receiver coils placed at the side of the body (Fig. 17d); these signals detect the water content of the body. It will take some time for the precession to die away, as the nuclei (b)
17 584 Physiology or Medicine 1979 again realign themselves with the magnetic field. The measurement of this time is important as it gives some information about the nature of the tissue under investigation. It approximates to an exponential decay of the order of tenths of a second. (It is known as T 1 or the spin lattice relaxation time). METHOD OF PRODUCING AN NMR PICTURE The procedures above refer only to a method of tissue detection. In order to produce a picture which maps the difference of tissue within the body it is necessary to independently measure small volumes of material across it. In NMR imaging this is done by applying a small magnetic field gradient across the body in addition to the main uniform field. The frequency of the nuclei, being dependent upon the magnetic field, will resonate at different frequencies across the body according to the magnitude of the field gradient present (Fig. 18). In one method of NMR imaging, the frequencies received in the coil can be separated (by Fourier analysis) and the whole spectrum of frequencies will represent a series of line integrals across the body, each frequency representing the amount of hydrogen nuclei resonating along that particular line. As a comparison with CT this is equivalent to one X-ray sweep across the body at a particular angle. A number of sweeps can be repeated at different angles by rotating the gradient field, and sufficient data can be built up to reconstruct a picture in similar way to that in which a CT picture is constructed. Fig. 18. Field gradient applied.
18 Computed Medical Imaging 585 COMPARISONS OF NMR WITH CT It is early to predict with certainty the levels of accuracy of a future NMR system, but one could speculate in the following way to illustrate its possible advantages. Fig. 19a illustrates approximately the number of levels about noise one would expect CT to be able to discriminate in tissue when an average scan is taken. It detects mainly one variable - density. It also detects a minor one - atomic number, which relies upon the photo-electric effect for separation. The discrimination of iodine from tissue by subtraction of two pictures at different X-ray energies is the most used example. In comparison, Fig. 19b shows the variables one would expect to detect in NMR. It may be possible to separate more than one decay time (the figure indicates that these may be three). If the sensitivity above noise is such that it is possible to select three levels in each of the three decay variables, there should be 27 possible permutations to characterise the tissue to be displayed as against the nine levels of tissue discrimination usually displayed on CT picture (Fig. 19a). This illustrates the major advantage of NMR but is only speculative. Fig. 19. Comparison between CT and NMR - showing the variables one would expect to find in tissue in both systems. (b)
19 586 Physiology or Medicine 1979 However, CT has other advantages: Fat in CT is very easily discriminated with respect to tissue (over 30 levels). For comparison, it is poorly discriminated in NMR. So far there are indications that the picture resolution on CT is considerably better than in NMR, and a picture can be scanned in a considerably shorter time (2 to 3 sets.). With NMR it is usual to scan the patient over at least a minute or more to collect sufficient data for good tissue discrimination. It must be remembered that each NMR, T 1 measurement is very time consuming, as long relaxation times (tenths of a second) need to be measured, and a few hundred sets of these readings are required to reconstruct one picture. On the other hand, as far as is known, NMR is noninvasive and the long periods of scanning time that the patient may be subjected to should do him no harm. However, a systems design of NMR has not yet stabilised. There still exist many different avenues which may in the future reveal improvements in both speed and sensitivity. Despite the fact that it is not yet clearly known what the parameters are that it is measuring, it is felt that NMR has great possibilities for indicating more about the chemistry of the tissue being selected. It is a technique which could image water concentration, its impurities and its binding to macro-molecules in or between the cells of the body. It remains to be seen how this extra information can help diagnoses. Work on NMR is still in its early stages and has a long way to go. At the present time, the two techniques of CT and NMR should perhaps be seen not as potential competitors but rather as complementary techniques that can exist side by side; NMR providing us with information on the chemical composition of the tissue, and CT providing us with a means of visualising its position and shape. May I thank all those at EM1 Research Laboratories who have helped me so much in the past in my work - especially Steven Bates who worked on some of the early experiments. SELECTED REFERENCES 1. Ambrose J: Computerised transverse axial scanning (tomography). II Clinical application. Br J Radiol 46: , Ambrose J: Computerised X-ray scanning of the brain. J Neurosurg 40: , Brooks RA, Di Chiro RA: Theory of Image reconstruction in computed tomography, Radiology 117: , Cho ZH, Chan JK, Hall El, Kruger RP, McCaughey DC: A comparative study of 3-D image reconstruction algorithms with reference to number of projections and noise filtering, in Transactions of Nuclear Science, IEEE Catalog no. NS-22 (1), 1975, pp Hounsfield GN: Computerised transverse axial scanning (tomography) I. Description of system. Br J Radiol 46: , Pullen BR, Rutherford RA and Isherwood I: 1976 Medical Images: Formation Perception and Measurement. Proceedings of the Seventh L.H. Gray Conference (20-38) University of Leeds The Institute of Physics, John Wiley and Sons.
C1 Medical Imaging Modalities & Characteristics. 4005-759 Linwei Wang
C1 Medical Imaging Modalities & Characteristics 4005-759 Linwei Wang Major Types of Medical Imaging Modalities X-ray Imaging Computed Tomography (CT) Magnetic Resonance Imaging (MRI) Nuclear Imaging Positron
Magnetic Resonance Imaging
Magnetic Resonance Imaging What are the uses of MRI? To begin, not only are there a variety of scanning methodologies available, but there are also a variety of MRI methodologies available which provide
GE Medical Systems Training in Partnership. Module 8: IQ: Acquisition Time
Module 8: IQ: Acquisition Time IQ : Acquisition Time Objectives...Describe types of data acquisition modes....compute acquisition times for 2D and 3D scans. 2D Acquisitions The 2D mode acquires and reconstructs
X-Rays Benefits and Risks. Techniques that use x-rays
X-Rays Benefits and Risks X-rays are a form of electromagnetic radiation, just like light waves and radiowaves. Because X-rays have higher energy than light waves, they can pass through the body. X-rays
CT scanning. By Mikael Jensen & Jens E. Wilhjelm Risø National laboratory Ørsted DTU. (Ver. 1.2 4/9/07) 2002-2007 by M. Jensen and J. E.
1 Overview CT scanning By Mikael Jensen & Jens E. Wilhjelm Risø National laboratory Ørsted DTU (Ver. 1.2 4/9/07) 2002-2007 by M. Jensen and J. E. Wilhjelm) As it can be imagined, planar X-ray imaging has
E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE
E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE References for Nuclear Magnetic Resonance 1. Slichter, Principles of Magnetic Resonance, Harper and Row, 1963. chapter
Prof.M.Perucca CORSO DI APPROFONDIMENTO DI FISICA ATOMICA: (III-INCONTRO) RISONANZA MAGNETICA NUCLEARE
Prof.M.Perucca CORSO DI APPROFONDIMENTO DI FISICA ATOMICA: (III-INCONTRO) RISONANZA MAGNETICA NUCLEARE SUMMARY (I/II) Angular momentum and the spinning gyroscope stationary state equation Magnetic dipole
Computerized Tomography, X-rays, and the Radon Transform
1 Computerized Tomography, X-rays, and the Radon Transform 1.1 Introduction The purpose of this chapter is to give an informal introduction to the subject of tomography. There are very few mathematical
PHYSICAL METHODS, INSTRUMENTS AND MEASUREMENTS Vol. III - Medical and Industrial Tomography - W.B.Gilboy
MEDICAL AND INDUSTRIAL TOMOGRAPHY Department of Physics, University of Surrey, Guildford, Surrey, U.K. Keywords: Radiography, transmission tomography, emission tomography, microtomography, SPECT (single
Patient Prep Information
Stereotactic Breast Biopsy Patient Prep Information Imaging Services Cannon Memorial Hospital Watauga Medical Center Table Weight Limits for each facility Cannon Memorial Hospital Watauga Medical Center
Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9
Module 9 This module presents information on what X-rays are and how they are produced. Introduction Module 9, Page 2 X-rays are a type of electromagnetic radiation. Other types of electromagnetic radiation
P R E S E N T S Dr. Mufa T. Ghadiali is skilled in all aspects of General Surgery. His General Surgery Services include: General Surgery Advanced Laparoscopic Surgery Surgical Oncology Gastrointestinal
RADIOLOGY SERVICES. By Dr Lim Eng Kok 1
INTRODUCTION RADIOLOGY SERVICES By Dr Lim Eng Kok 1 Radiology is the branch of medicine that deals with the use of ionising (e.g. x- rays and radio-isotopes) and non-ionising radiation (e.g. ultrasound
Nuclear Magnetic Resonance (NMR) Spectroscopy cont... Recommended Reading:
Applied Spectroscopy Nuclear Magnetic Resonance (NMR) Spectroscopy cont... Recommended Reading: Banwell and McCash Chapter 7 Skoog, Holler Nieman Chapter 19 Atkins, Chapter 18 Relaxation processes We need
Basic Principles of Magnetic Resonance
Basic Principles of Magnetic Resonance Contents: Jorge Jovicich [email protected] I) Historical Background II) An MR experiment - Overview - Can we scan the subject? - The subject goes into the magnet -
13C NMR Spectroscopy
13 C NMR Spectroscopy Introduction Nuclear magnetic resonance spectroscopy (NMR) is the most powerful tool available for structural determination. A nucleus with an odd number of protons, an odd number
Proton Nuclear Magnetic Resonance Spectroscopy
Proton Nuclear Magnetic Resonance Spectroscopy Introduction: The NMR Spectrum serves as a great resource in determining the structure of an organic compound by revealing the hydrogen and carbon skeleton.
NUCLEAR MAGNETIC RESONANCE. Advanced Laboratory, Physics 407, University of Wisconsin Madison, Wisconsin 53706
(revised 4/21/03) NUCLEAR MAGNETIC RESONANCE Advanced Laboratory, Physics 407, University of Wisconsin Madison, Wisconsin 53706 Abstract This experiment studies the Nuclear Magnetic Resonance of protons
CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging
Physics of Medical X-Ray Imaging (1) Chapter 3 CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY 3.1 Basic Concepts of Digital Imaging Unlike conventional radiography that generates images on film through
Application of Nuclear Magnetic Resonance in Petroleum Exploration
Application of Nuclear Magnetic Resonance in Petroleum Exploration Introduction Darko Tufekcic, consultant email: [email protected] Electro-magnetic resonance method (GEO-EMR) is emerging as the
Contents. X-ray and Computed Tomography. Characterization of X-rays. Production of X-rays
J. E. Wilhjelm Ørsted TU Technical University of enmark, Bldg. 348, K-2800 Kongens Lyngby, enmark. X-ray and Computed Tomography Contents History and characterization of X-rays Conventional (projection)
4. It is possible to excite, or flip the nuclear magnetic vector from the α-state to the β-state by bridging the energy gap between the two. This is a
BASIC PRINCIPLES INTRODUCTION TO NUCLEAR MAGNETIC RESONANCE (NMR) 1. The nuclei of certain atoms with odd atomic number, and/or odd mass behave as spinning charges. The nucleus is the center of positive
Pulsed Fourier Transform NMR The rotating frame of reference. The NMR Experiment. The Rotating Frame of Reference.
Pulsed Fourier Transform NR The rotating frame of reference The NR Eperiment. The Rotating Frame of Reference. When we perform a NR eperiment we disturb the equilibrium state of the sstem and then monitor
Purchasing a cardiac CT scanner: What the radiologist needs to know
Purchasing a cardiac CT scanner: What the radiologist needs to know Maria Lewis ImPACT St George s Hospital, London [email protected] CT scanner development Slice wars 1998 Increased z-coverage
Functional neuroimaging. Imaging brain function in real time (not just the structure of the brain).
Functional neuroimaging Imaging brain function in real time (not just the structure of the brain). The brain is bloody & electric Blood increase in neuronal activity increase in metabolic demand for glucose
Medical Applications of radiation physics. Riccardo Faccini Universita di Roma La Sapienza
Medical Applications of radiation physics Riccardo Faccini Universita di Roma La Sapienza Outlook Introduction to radiation which one? how does it interact with matter? how is it generated? Diagnostics
1. In the general symbol cleus, which of the three letters. 2. What is the mass number of an alpha particle?
1. In the general symbol cleus, which of the three letters Z A X for a nu represents the atomic number? 2. What is the mass number of an alpha particle? 3. What is the mass number of a beta particle? 4.
Digital radiography conquers the veterinary world
Digital radiography conquers the veterinary world Author: Dirk De Langhe Increasingly, veterinarians are using medical imaging to diagnose their patients. There is a corresponding tendency towards replacing
The Hydrogen Atom Is a Magnet. http://www.seed.slb.com/en/scictr/watch/gashydrates/detecting.htm
The Hydrogen Atom Is a Magnet Nuclear Magnetic Resonance Spectroscopy (NMR) Proton NMR A hydrogen nucleus can be viewed as a proton, which can be viewed as a spinning charge. As with any spinning charge,
Chapter 18: The Structure of the Atom
Chapter 18: The Structure of the Atom 1. For most elements, an atom has A. no neutrons in the nucleus. B. more protons than electrons. C. less neutrons than electrons. D. just as many electrons as protons.
Atomic and Nuclear Physics
Atomic and Nuclear Physics Nuclear Physics Nuclear Magnetic Resonance LD Physics Leaflets P6.5.3.1 Nuclear magnetic resonance in polystyrene, glycerine and teflon Objects g Nuclear Magnetic Resonance on
Diffusione e perfusione in risonanza magnetica. E. Pagani, M. Filippi
Diffusione e perfusione in risonanza magnetica E. Pagani, M. Filippi DW-MRI DIFFUSION-WEIGHTED MRI Principles Diffusion results from a microspic random motion known as Brownian motion THE RANDOM WALK How
Automation of a CT Acquisition: A System-based User-Support. 1. Introduction. Bärbel KRATZ 1, Frank HEROLD 1, Malte KURFISS 1
11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic Automation of a CT Acquisition: A System-based User-Support More Info at Open Access Database
Structure and Properties of Atoms
PS-2.1 Compare the subatomic particles (protons, neutrons, electrons) of an atom with regard to mass, location, and charge, and explain how these particles affect the properties of an atom (including identity,
PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS
PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS 1. Photons 2. Photoelectric Effect 3. Experimental Set-up to study Photoelectric Effect 4. Effect of Intensity, Frequency, Potential on P.E.
NMR Techniques Applied to Mineral Oil, Water, and Ethanol
NMR Techniques Applied to Mineral Oil, Water, and Ethanol L. Bianchini and L. Coffey Physics Department, Brandeis University, MA, 02453 (Dated: February 24, 2010) Using a TeachSpin PS1-A pulsed NMR device,
Atomic and Nuclear Physics Laboratory (Physics 4780)
Gamma Ray Spectroscopy Week of September 27, 2010 Atomic and Nuclear Physics Laboratory (Physics 4780) The University of Toledo Instructor: Randy Ellingson Gamma Ray Production: Co 60 60 60 27Co28Ni *
How an electronic shutter works in a CMOS camera. First, let s review how shutters work in film cameras.
How an electronic shutter works in a CMOS camera I have been asked many times how an electronic shutter works in a CMOS camera and how it affects the camera s performance. Here s a description of the way
8.1 Radio Emission from Solar System objects
8.1 Radio Emission from Solar System objects 8.1.1 Moon and Terrestrial planets At visible wavelengths all the emission seen from these objects is due to light reflected from the sun. However at radio
TISSUE MIMICKING GEL QUALITY LE PHANTOM SERIES DESIGN. performance the ultrasound labs ofand. icking material has the same attenuation mim-
QUALITY Tissue Benefits Mimicking of s RMI recognized RMI as the ultrasound standard phantoms for quality are performance the ultrasound labs ofand hospitals, manufacturers. clinics Sophisticated and ultrasound
Baylor Radiosurgery Center
Radiosurgery Center Baylor Radiosurgery Center Sophisticated Radiosurgery for both Brain and Body University Medical Center at Dallas Radiosurgery Center 3500 Gaston Avenue Hoblitzelle Hospital, First
Trans Fats. What is a trans fat? Trans fatty acids, or trans fats as they are known, are certain
Trans Fats What is a trans fat? Trans fatty acids, or trans fats as they are known, are certain fats found in such foodstuffs as vegetable shortenings, margarines, crackers, candies baked goods and many
Lab 4: Magnetic Force on Electrons
Lab 4: Magnetic Force on Electrons Introduction: Forces on particles are not limited to gravity and electricity. Magnetic forces also exist. This magnetic force is known as the Lorentz force and it is
NMR - Basic principles
NMR - Basic principles Subatomic particles like electrons, protons and neutrons are associated with spin - a fundamental property like charge or mass. In the case of nuclei with even number of protons
Intensity-Modulated Radiation Therapy (IMRT)
Scan for mobile link. Intensity-Modulated Radiation Therapy (IMRT) Intensity-modulated radiotherapy (IMRT) uses linear accelerators to safely and painlessly deliver precise radiation doses to a tumor while
Study of the Human Eye Working Principle: An impressive high angular resolution system with simple array detectors
Study of the Human Eye Working Principle: An impressive high angular resolution system with simple array detectors Diego Betancourt and Carlos del Río Antenna Group, Public University of Navarra, Campus
Generation and Detection of NMR Signals
Generation and Detection of NMR Signals Hanudatta S. Atreya NMR Research Centre Indian Institute of Science NMR Spectroscopy Spin (I)=1/2h B 0 Energy 0 = B 0 Classical picture (B 0 ) Quantum Mechanical
Radiation therapy involves using many terms you may have never heard before. Below is a list of words you could hear during your treatment.
Dictionary Radiation therapy involves using many terms you may have never heard before. Below is a list of words you could hear during your treatment. Applicator A device used to hold a radioactive source
What is Radiology and Radiologic Technology?
What is Radiology and Radiologic Technology? Note: Prospective CSI Radiologic Technology students are encouraged to print this document out and study it thoroughly before applying for admission to the
Nuclear Magnetic Resonance
Nuclear Magnetic Resonance Practical Course M I. Physikalisches Institut Universität zu Köln May 15, 2014 Abstract Nuclear magnetic resonance (NMR) techniques are widely used in physics, chemistry, and
2. Spin Chemistry and the Vector Model
2. Spin Chemistry and the Vector Model The story of magnetic resonance spectroscopy and intersystem crossing is essentially a choreography of the twisting motion which causes reorientation or rephasing
Pulsed Nuclear Magnetic Resonance An Experiment for UCSB s Advanced Laboratory
1 Pulsed Nuclear Magnetic Resonance An Experiment for UCSB s Advanced Laboratory Foreword Pulsed nuclear magnetic resonance is fascinating in its own right, and is also an incredibly important tool for
Nuclear Magnetic Resonance Spectroscopy
Nuclear Magnetic Resonance Spectroscopy Introduction NMR is the most powerful tool available for organic structure determination. It is used to study a wide variety of nuclei: 1 H 13 C 15 N 19 F 31 P 2
World-first Proton Pencil Beam Scanning System with FDA Clearance
Hitachi Review Vol. 58 (29), No.5 225 World-first Proton Pencil Beam Scanning System with FDA Clearance Completion of Proton Therapy System for MDACC Koji Matsuda Hiroyuki Itami Daishun Chiba Kazuyoshi
Force on Moving Charges in a Magnetic Field
[ Assignment View ] [ Eðlisfræði 2, vor 2007 27. Magnetic Field and Magnetic Forces Assignment is due at 2:00am on Wednesday, February 28, 2007 Credit for problems submitted late will decrease to 0% after
R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.
R/F Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening Department of Radiology, National Cancer Center Hospital East Kaoru Shimizu Ms. Kaoru Shimizu 1. Introduction
Nuclear Magnetic Resonance
Nuclear Magnetic Resonance Author: James Dragan Lab Partner: Stefan Evans Physics Department, Stony Brook University, Stony Brook, NY 794. (Dated: December 5, 23) We study the principles behind Nuclear
Precession of spin and Precession of a top
6. Classical Precession of the Angular Momentum Vector A classical bar magnet (Figure 11) may lie motionless at a certain orientation in a magnetic field. However, if the bar magnet possesses angular momentum,
X-ray (Radiography) - Bone
Scan for mobile link. X-ray (Radiography) - Bone Bone x-ray uses a very small dose of ionizing radiation to produce pictures of any bone in the body. It is commonly used to diagnose fractured bones or
A METHOD OF CALIBRATING HELMHOLTZ COILS FOR THE MEASUREMENT OF PERMANENT MAGNETS
A METHOD OF CALIBRATING HELMHOLTZ COILS FOR THE MEASUREMENT OF PERMANENT MAGNETS Joseph J. Stupak Jr, Oersted Technology Tualatin, Oregon (reprinted from IMCSD 24th Annual Proceedings 1995) ABSTRACT The
QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET
Centers for Quantitative Imaging Excellence (CQIE) LEARNING MODULE QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET American College of Radiology Clinical Research Center v.1 Centers for Quantitative
Cathode Ray Tube. Introduction. Functional principle
Introduction The Cathode Ray Tube or Braun s Tube was invented by the German physicist Karl Ferdinand Braun in 897 and is today used in computer monitors, TV sets and oscilloscope tubes. The path of the
Monday 11 June 2012 Afternoon
Monday 11 June 2012 Afternoon A2 GCE PHYSICS B (ADVANCING PHYSICS) G495 Field and Particle Pictures *G412090612* Candidates answer on the Question Paper. OCR supplied materials: Data, Formulae and Relationships
Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL
Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL X-ray ZOOM RECONSTRUCTION Flat Panel Detector (FPD) Automatic Positioning Function For ø 40 x H 40 mm, ø 60 x H 60 mm,
Main properties of atoms and nucleus
Main properties of atoms and nucleus. Atom Structure.... Structure of Nuclei... 3. Definition of Isotopes... 4. Energy Characteristics of Nuclei... 5. Laws of Radioactive Nuclei Transformation... 3. Atom
Clinical Physics. Dr/Aida Radwan Assistant Professor of Medical Physics Umm El-Qura University
Clinical Physics Dr/Aida Radwan Assistant Professor of Medical Physics Umm El-Qura University Physics of Radiotherapy using External Beam Dose distribution PHANTOMS Basic dose distribution data are usually
BME 501 - Introduction to BME. Bioelectrical Engineering Part: Medical Imaging
BME 501 - Introduction to BME Bioelectrical Engineering Part: Medical Imaging Reference Textbook: Principles of Medical Imaging, by Shung, Smith and Tsui Lecturer: Murat EYÜBOĞLU, Ph.D. Dept. of Electrical
IONISING RADIATION. X-rays: benefit and risk
IONISING RADIATION X-rays: benefit and risk Impress Federal Office for Radiation Protection Postfach 10 01 49 D - 38201 Salzgitter Telephone: + 49 (0) 30 18333-0 Fax: + 49 (0) 30 18333-1885 Website: www.bfs.de
NMR SPECTROSCOPY. Basic Principles, Concepts, and Applications in Chemistry. Harald Günther University of Siegen, Siegen, Germany.
NMR SPECTROSCOPY Basic Principles, Concepts, and Applications in Chemistry Harald Günther University of Siegen, Siegen, Germany Second Edition Translated by Harald Günther JOHN WILEY & SONS Chichester
The Field. Radiologic technologists take x-rays and administer nonradioactive materials into patients' bloodstreams for diagnostic purposes.
Radiologic Technologist Overview The Field - Specialty Areas - Preparation - Day in the Life - Earnings - Employment - Career Path Forecast - Professional Organizations The Field Radiologic technologists
FXA 2008. UNIT G485 Module 4 5.4.3 Ultrasound. Candidates should be able to :
1 Candidates should be able to : ULTRASOUND Describe the properties of ultrasound. ULTRASOUND is any sound wave having a frequency greater than the upper frequency limit of human hearing (20 khz). Describe
Used to determine relative location of atoms within a molecule Most helpful spectroscopic technique in organic chemistry Related to MRI in medicine
Structure Determination: Nuclear Magnetic Resonance CHEM 241 UNIT 5C 1 The Use of NMR Spectroscopy Used to determine relative location of atoms within a molecule Most helpful spectroscopic technique in
Spiral CT: Single and Multiple Detector Systems. AAPM Refresher Course Nashville, TN July 28,1999
Spiral CT: Single and Multiple Detector Systems AAPM Refresher Course Nashville, TN July 28,1999 Mike McNitt-Gray, PhD, DABR Assistant Professor UCLA Radiological Sciences [email protected] X-Ray
Chapter NP-5. Nuclear Physics. Nuclear Reactions TABLE OF CONTENTS INTRODUCTION OBJECTIVES 1.0 NUCLEAR REACTIONS 2.0 NEUTRON INTERACTIONS
Chapter NP-5 Nuclear Physics Nuclear Reactions TABLE OF CONTENTS INTRODUCTION OBJECTIVES 1.0 2.0 NEUTRON INTERACTIONS 2.1 ELASTIC SCATTERING 2.2 INELASTIC SCATTERING 2.3 RADIATIVE CAPTURE 2.4 PARTICLE
Nuclear Physics. Nuclear Physics comprises the study of:
Nuclear Physics Nuclear Physics comprises the study of: The general properties of nuclei The particles contained in the nucleus The interaction between these particles Radioactivity and nuclear reactions
Feasibility Study of Neutron Dose for Real Time Image Guided. Proton Therapy: A Monte Carlo Study
Feasibility Study of Neutron Dose for Real Time Image Guided Proton Therapy: A Monte Carlo Study Jin Sung Kim, Jung Suk Shin, Daehyun Kim, EunHyuk Shin, Kwangzoo Chung, Sungkoo Cho, Sung Hwan Ahn, Sanggyu
Medical Image Processing on the GPU. Past, Present and Future. Anders Eklund, PhD Virginia Tech Carilion Research Institute [email protected].
Medical Image Processing on the GPU Past, Present and Future Anders Eklund, PhD Virginia Tech Carilion Research Institute [email protected] Outline Motivation why do we need GPUs? Past - how was GPU programming
Encoders for Linear Motors in the Electronics Industry
Technical Information Encoders for Linear Motors in the Electronics Industry The semiconductor industry and automation technology increasingly require more precise and faster machines in order to satisfy
Determination of Molecular Structure by MOLECULAR SPECTROSCOPY
Determination of Molecular Structure by MOLEULAR SPETROSOPY hemistry 3 B.Z. Shakhashiri Fall 29 Much of what we know about molecular structure has been learned by observing and analyzing how electromagnetic
Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry
Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry Jon H. Hardesty, PhD and Bassam Attili, PhD Collin College Department of Chemistry Introduction: In the last lab
How are Parts of the Brain Related to Brain Function?
How are Parts of the Brain Related to Brain Function? Scientists have found That the basic anatomical components of brain function are related to brain size and shape. The brain is composed of two hemispheres.
Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics
Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics PART I Geiger Tube: Optimal Operating Voltage and Resolving Time Objective: To become acquainted with the operation and characteristics
What If I Have a Spot on My Lung? Do I Have Cancer? Patient Education Guide
What If I Have a Spot on My Lung? Do I Have Cancer? Patient Education Guide A M E R I C A N C O L L E G E O F C H E S T P H Y S I C I A N S Lung cancer is one of the most common cancers. About 170,000
Hole s Human Anatomy and Physiology Eleventh Edition. Mrs. Hummer Hanover Area Jr./Sr. High School. Chapter 1 Introduction to Anatomy and Physiology
Hole s Human Anatomy and Physiology Eleventh Edition Mrs. Hummer Hanover Area Jr./Sr. High School Chapter 1 Introduction to Anatomy and Physiology 1 Chapter 1 Introduction to Human Anatomy and Physiology
Procedures/risks: Radiology (CT, DXA, MRI, ultrasound, X-ray)
Procedures/risks: Radiology (CT, DXA, MRI, ultrasound, X-ray) Computerized Axial Tomography (CT): Procedure: A Computerized Axial Tomography (CT) scan [of your heart] involves holding your breath for a
5 Factors Affecting the Signal-to-Noise Ratio
5 Factors Affecting the Signal-to-Noise Ratio 29 5 Factors Affecting the Signal-to-Noise Ratio In the preceding chapters we have learned how an MR signal is generated and how the collected signal is processed
Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies
Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies (Ci), where 1 Ci = 3.7x10 10 disintegrations per second.
Measuring Line Edge Roughness: Fluctuations in Uncertainty
Tutor6.doc: Version 5/6/08 T h e L i t h o g r a p h y E x p e r t (August 008) Measuring Line Edge Roughness: Fluctuations in Uncertainty Line edge roughness () is the deviation of a feature edge (as
THORACIC DIAGNOSTIC ASSESMENT PROGRAM (DAP) PATIENT INFORMATION FOR:
central east regional cancer program in partnership with cancer care ontario THORACIC DIAGNOSTIC ASSESMENT PROGRAM (DAP) PATIENT INFORMATION FOR: Thoracic dap booklet March2012.indd 1 SCHEDULED TESTS YOUR
Chapter 22: Electric motors and electromagnetic induction
Chapter 22: Electric motors and electromagnetic induction The motor effect movement from electricity When a current is passed through a wire placed in a magnetic field a force is produced which acts on
The accurate calibration of all detectors is crucial for the subsequent data
Chapter 4 Calibration The accurate calibration of all detectors is crucial for the subsequent data analysis. The stability of the gain and offset for energy and time calibration of all detectors involved
............... [2] At the time of purchase of a Strontium-90 source, the activity is 3.7 10 6 Bq.
1 Strontium-90 decays with the emission of a β-particle to form Yttrium-90. The reaction is represented by the equation 90 38 The decay constant is 0.025 year 1. 90 39 0 1 Sr Y + e + 0.55 MeV. (a) Suggest,
How To Treat Cancer With Proton Therapy
Proton therapy at the Paul Scherrer Institute PSI proton therapy for tumours of the eye (OPTIS). The patient s head is fixed using a mask and a bite block. Actual irradiation of the eye tumour lasts less
1. Orthovoltage vs. megavoltage x-rays. (AL) External beam radiation sources: Orthovoltage radiotherapy: 200-500 kv range
1. Orthovoltage vs. megavoltage x-rays. (AL) External beam radiation sources: Orthovoltage radiotherapy: 200-500 kv range The radiation from orthovoltage units is referred to as x-rays, generated by bombarding
Nuclear Magnetic Resonance
Nuclear Magnetic Resonance NMR is probably the most useful and powerful technique for identifying and characterizing organic compounds. Felix Bloch and Edward Mills Purcell were awarded the 1952 Nobel
Radiation Strip Thickness Measurement Systems
Radiation Strip Thickness Measurement Systems During the past years we have increased our sales of radiometric Vollmer strip thickness measurement systems, i.e. X-ray or isotope gauges, dramatically. Now,
1. Units of a magnetic field might be: A. C m/s B. C s/m C. C/kg D. kg/c s E. N/C m ans: D
Chapter 28: MAGNETIC FIELDS 1 Units of a magnetic field might be: A C m/s B C s/m C C/kg D kg/c s E N/C m 2 In the formula F = q v B: A F must be perpendicular to v but not necessarily to B B F must be