1 Certificate of Compliance Certificate: (LR 89729) Master Contract: Issued to: Metso Automation USA, Inc. 44 Bowditch Dr Shrewsbury, MA USA Attention: Donna Baczewski The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Issued by: Jelena Dzeletovic Jelena Dzeletovic PRODUCTS CLASS CLASS VALVES - Actuators - For Hazardous Locations-Certified to U.S. Standard - VALVES - Actuators - For Hazardous Locations Class I, Groups C and D; Class II, Groups E, F and G; Class III; Encl. Type 4, 4X: Electric valve actuators, Valvcon series ADCWX or private brand series 91, 92, 93, 91X, 92X, 93X, CSxxx- Ex, ACSxxx-N, Q30090 NGA 300, Q30091 NGA 600, Q30096 NGA 300 B, Q30097 NGA 600 B; 150, 300 and 600 lb-in, 12Vdc/24Vdc, 2.8A/1.7A max, 24Vac/115Vac/230Vac, 60Hz, 2.5A/0.6A/0.5A max., duty cycle 100%, ambient temperature rating -40 F to 130 F. Electric valve actuators, Valvcon series VWX, IWX or private brand series 81, 81X, and CSxxx-Ex; 150 lb-in, 115Vac/230Vac, 60Hz, 0.61A/0.44A max., duty cycle 75%; 8 seconds ON, 3 seconds OFF, Class B insulation, enclosure rated Type 4X, Electric valve actuators, Valvcon series VWX, IWX or private brand series 82, 82X, and CSxxx-Ex; 300 lb-in, 115Vac/230Vac, 60Hz, 0.61A/0.44A max., duty cycle 75%; 15 seconds ON, 5 seconds OFF, Class B insulation, enclosure rated Type 4X, DQD 507 Rev Page: 1

2 Electric valve actuators, Valvcon series VWX, IWX or private brand series 83, 83X, and CSxxx-Ex; 600 lbin, 115Vac/230Vac, 60Hz, 0.61A/0.44A max., duty cycle 75%; 30 seconds ON, 10 seconds OFF, Class B insulation, enclosure rated Type 4X, Electric valve actuators, Valvcon series LADCWX or private brand series 94, 94X, CLxxxx-Ex, ACLxxxx- N, Q30092 NGA 1000, Q30093 NGA 1500, Q30094 NGA 2000, Q30095 NGA 3000, Q30098 NGA 1000 B, Q30099 NGA 1500 B, Q30100 NGA 2000 B, Q30101 NGA 3000 B; 1000, 1500, 2000, 2500 and 3000 lb-in (large enclosure), 12Vdc/24Vdc, 4.3A/2.4A max, 24Vac/115Vac/230Vac, 60Hz, 3.5A/0.9A/0.6A max., duty cycle 100%, ambient temperature rating -40 F to 130 F. Electric valve actuators, Valvcon Series LVWX, LIWX or private brand series 84, 84X, CLxxxx-Ex; 1000 lb-in, 115Vac/230Vac, 60Hz, 0.72A/0.46A max., duty cycle 75%; 25 seconds ON, 9 seconds OFF, Class B insulation, enclosure rated Type 4X, Electric valve actuators, Valvcon Series LVWX, LIWX or private brand series CLxxxx-Ex; 1500 lb-in, 115Vac/230Vac, 60Hz, 0.72A/0.46A max., duty cycle 75%; 40 seconds ON, 14 seconds OFF, Class B insulation, enclosure rated Type 4X, Electric valve actuators, Valvcon Series LVWX, LIWX or private brand series CLxxxx-Ex; 2000 lb-in, 115Vac/230Vac, 60Hz, 0.72A/0.46A max., duty cycle 75%; 55 seconds ON, 19 seconds OFF, Class B insulation, enclosure rated Type 4X, Electric valve actuators, Valvcon Series LVWX, LIWX or private brand series CLxxxx-Ex; 2500 lb-in, 115Vac/230Vac, 60Hz, 0.72A/0.46A max., duty cycle 75%; 70 seconds ON, 24 seconds OFF, Class B insulation, enclosure rated Type 4X, Electric valve actuators, Valvcon Series LVWX, LIWX or private brand series CLxxxx-Ex; 3000 lb-in, 115Vac/230Vac, 60Hz, 0.72A/0.46A max., duty cycle 55%; 75 seconds ON, 62 seconds OFF, Class B insulation, enclosure rated Type 4X, Electric valve actuators, Series Q6 600 lb-in, 12Vdc, 1.1A max., duty cycle 80%; 15 seconds ON, 3 seconds OFF, enclosure rated Type 4X, DQD 507 Rev Page: 2

3 Electric valve actuators, Series QX: 150 lb-in, 12Vdc/24Vdc, 1.9A/2.4A max, duty cycle 80%; 5/3 seconds ON, 2/1 seconds OFF, enclosure rated Type 4X, 300 lb-in, 12Vdc/24Vdc, 1.9A/2.4A max, duty cycle 80%; 10/5 seconds ON, 3/2 seconds OFF, enclosure rated Type 4X, 600 lb-in, 12Vdc/24Vdc, 1.9A/2.4A max, duty cycle 80%; 15/8 seconds ON, 3/2 seconds OFF, enclosure rated Type 4X, 1000 lb-in, 12Vdc/24Vdc, 3.5A max, duty cycle 80%; 15 seconds ON, 4 seconds OFF, enclosure rated Type 4X, 1500 lb-in, 12Vdc/24Vdc, 3.5A max, duty cycle 80%; 20 seconds ON, 5 seconds OFF, enclosure rated Type 4X, 2000 lb-in, 12Vdc/24Vdc, 4.8A max, duty cycle 80%; 25 seconds ON, 7 seconds OFF, enclosure rated Type 4X, 2500 lb-in, 12Vdc/24Vdc, 4.8A max, duty cycle 80%; 30 seconds ON, 8 seconds OFF, enclosure rated Type 4X, 3000 lb-in, 12Vdc/24Vdc, 4.8A max, duty cycle 80%; 30 seconds ON, 8 seconds OFF, enclosure rated Type 4X, Notes: 1.0 Standard features: - Dual conduit entries; - Position Indication (optional on Q6); 2.0 Options: 2.1 Series VWX and LVWX actuators can have the following options: C, H, I, J, K, P, S1, S2, S3, T, U Y, and Z. Position Indication - (Standard); indicator shaft VC001355; Electronic Positioner Board - (Option code "C"); Positioner board VC002975, or VC002475; Tropical Heater and Thermostat - (Option Code H ); Heater thermostat assembly VC or VC002391; ISO Metric Output - (Option Code I ); Output coupling VC007303, VC007304, VC007204, VC007205; Speed Control/Timer Board (Option code J ); Board VC002770; Brake - (Option Code K ); Solenoid brake VC002660; Feedback Potentiometer - (Option Code P"); Potentiometer VC002067; Heater and Thermostat - (Option Code "T ); Heater thermostat assembly VC or VC002373; DQD 507 Rev Page: 3

4 Iso/Read-back board - (Option Code U ); Read back board VC002065; Keyed Output (Option code Y ); Keyed shaft VC007224, VC007324, VC or VC007480; De-clutching Hand wheel - (Override Shaft, Option Code "Z"); Hand wheel VC001604, VC or VC Series IWX and LIWX actuators can have the following options: AS, DN, H, I, K, LN, S1, S2, S3, T Y, and Z. AS-i Electronic Control Board - (Option Code AS ); Control board VC002041; DeviceNet Protocol (Option Code DN ); Network Interface Board VC002370, DeviceNet Module MA (StoneL Module # IM461135A); Tropical Heater and Thermostat - (Option Code H ); Heater thermostat assembly VC or VC002392; ISO Metric Output - (Option Code I ); Output coupling VC007303, VC007304, VC or VC007205; Brake - (Option Code K ); Brake solenoid VC002660; LonWorks Electronic Control Board - (Option Code LN ); Control board VC002040; Heater and Thermostat - (Option Code "T"); Heater thermostat assembly VC002372, VC002373; Keyed Output (Option code Y ); Keyed shaft VC007224, VC007324, VC or VC007480; VC or VC Series ADCWX actuators can have the following options: C, CL2, H, I, MB, L2, L4, R2, R3, S1, S2, S3, T, U2, UL2, U4, UL4, U6, UL6, Y, and Z. Brake - (Standard); Power Board (Standard) VC002360; Power Supply Board (Standard) VC /230Vac, VC /24Vdc, VC Vac; Electronic Positioner Board (4-20 ma or 0-10V, Option code "C"): Positioner board VC002980; Electronic Positioner Board With Battery Backup(4-20 ma or 0-10V, Option code "CL2"): Positioner board VC002980, Battery VC001573; Tropical Heater and Thermostat - (Option Code "H"); Heater thermostat assembly VC002382, VC002397, VC or VC002394; ISO Metric Output - (Option Code I ); Output coupling VC007303, VC007304, VC or VC007205; Modbus Communication (Option Code MB ); Modbus Communication Board VCB00020; On/Off Control Board With Battery Backup (Option Code "L2"): Control board VC002970, Battery VC001573; On/Off Control Board 180 Degree With Battery Backup (Option Code "L4"): Control board VC002970, Battery VC001573; On/Off Control Board (Option Code "R2"): Control board VC002970; On/Off Control Board 180 Degree (Option Code "R3"): Control board VC002970; Heater and Thermostat - (Option Code "T"); Heater thermostat assembly VC002371, VC002397, VC or VC002387; On/Off / Positioner Board Option Codes U2, U4, or U6 ; Universal On/Off / Positioner Board VCB00010; DQD 507 Rev Page: 4

5 On/Off / Positioner Board Option Codes UL2, UL4, or UL6 ; Universal On/Off / Positioner Board with Battery Back Up VCB00010 and VC001572; Keyed Output (Option code Y ); Keyed shaft VC or VC007380; VC Series LADCWX actuators can have the following options: C, CL3, H, I, MB, L3, L5, R2, R3, S1, S2, S3, T, U2, UL3, U4, UL5, U6, UL7, Y, and Z. Brake - (Standard); Power Board (Standard) VC002360; Power Supply Board (Standard) VC /230Vac, VC /24Vdc, VC Vac; Electronic Positioner Board (4-20 ma or 0-10V, Option code "C"): Positioner board VC002980; Electronic Positioner Board With Battery Backup (4-20 ma or 0-10V, Option code "CL3"): Positioner board VC002980, Battery VC002509; Tropical Heater and Thermostat - (Option Code "H"); Heater thermostat assembly VC002382, VC002397, VC or VC002394; ISO Metric Output Option code I : Output Coupling VC007303, VC007304, VC007204, VC007205; Modbus Communication (Option Code MB ); Modbus Communication Board VCB00020; On/Off Control Board 90 Degree With Battery Backup (Option Code "L3"): Control board VC002970, Battery VC002509; On/Off Control Board 180 Degree With Battery Backup (Option Code "L5"): Control board VC002970, Battery VC002509; On/Off Control Board (Option Code "R2"): Control board VC002970; On/Off Control Board 180 Degree (Option Code "R3"): Control board VC002970; Heater and Thermostat - (Option Code "T"); Heater thermostat assembly VC002371, VC002397, VC or VC002387; On/Off / Positioner Board Option Codes U2, U4, or U6 ; Universal On/Off / Positioner Board VCB00010; On/Off / Positioner Board Option Codes UL3, UL5, or UL7 ; Universal On/Off / Positioner Board with Battery Back Up VCB00010 and VC002509; Keyed Output (Option code Y ); Keyed shaft VC or VC007480; VC Series Q6 actuators can have the following options: H, I, T, Y and Z Position Indication - (Standard on Q6.2.2, Q6.2.4F, Q6.2.1, Q6.2.3 and Q6.2.2-NGA04); Indicator shaft VC001355; Brake (Standard; relay built-in on power boards); Power Board (Q6.2.2, Q6.2.4, Q6.2.4F and Q6.2.2-NGA04) VC001382; Power Board (Q6.2.1 and Q6.2.3) VC002250; Tropical Heater and Thermostat - (Option Code "H"); Heater thermostat assembly VC002388; ISO Metric Output - (Option Code I ); Output coupling VC007303, VC007304; Heater and Thermostat - (Option Code "T"); Heater thermostat assembly VC002386; Keyed Output (Option code Y ); Keyed shaft VC or VC007380; DQD 507 Rev Page: 5

6 VC Series QX actuators can have the following options:h, I, T, Y and Z Brake - (Standard; relay integral to motor harness); Additional Limit Switches - (Standard); Limit Tropical Heater and Thermostat - (Option Code "H"); Heater thermostat assembly VC or VC002394; ISO Metric Output - (Option Code I ); Output coupling VC007303, VC007304, VC or VC007205; Heater and Thermostat - (Option Code "T"); Heater thermostat assembly VC or VC002387; Keyed Output (Option code Y ); Keyed shaft VC007224, VC007324, VC or VC007480; De-clutching Hand wheel - (Override Shaft, Option Code "Z"); Hand wheel VC001604; Override shaft VC001622, VC APPLICABLE REQUIREMENTS CAN/CSA Std C22.2 No CSA Std C22.2 No (R 2004) Locations CSA Std C22.2 No. 30-M1986 (R 2007) Locations CAN/CSA Std C22.2 No. 94-M94 (R 2004) - CSA Std C22.2 No General Requirements - Canadian Electrical Code, Part II - Enclosures for Use in Class II Groups E, F, and G Hazardous - Explosion-Proof Enclosures for Use in Class I Hazardous Special Purpose Enclosures - Electrically Operated Valves ANSI/UL Std 50, 12th Edition - Enclosures for Electrical Equipment, Non-Environmental Considerations UL Std 429, 6th Edition UL Std 1002, 7th Edition Locations - Electrically Operated Valves - Electrically Operated Valves for Use in Hazardous (Classified) ANSI/UL Standard 1203, 4th Edition - Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for Use in Hazardous (Classified) Locations DQD 507 Rev Page: 6

TorqPlus TM Electric Valve Actuators and Controls

TorqPlus TM Electric Valve Actuators and Controls TorqPlus TM Electric Valve Actuators and Controls Torque 150 IN/LB 600 IN/LB The Engineered Solution Bettis TorqPlus quality line of electric actuators are designed for quarter turn applications ball,

More information

Know-how makes the difference. Electrical Actuators

Know-how makes the difference. Electrical Actuators Know-how makes the difference Electrical Actuators With Dansk Ventil Center as your business partner, you are always guaranteed a wide and well sorted product range and a unique technical know-how Product

More information

A descriptive definition of valve actuators

A descriptive definition of valve actuators A descriptive definition of valve actuators Abstract A valve actuator is any device that utilizes a source of power to operate a valve. This source of power can be a human being working a manual gearbox

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

This chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets.

This chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets. 1/99 Modutrol Motors Selection Guide This chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets. 2-POSITION SPRING

More information

Centro-Matic Automatic Lubrication Systems System Controls

Centro-Matic Automatic Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function Document No. 155-751 SKP15U.. Description Only when assembled to Series VGU Gas valves SKP15 electro-hydraulic actuators combine with

More information

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner Quick Stepper 3G ECP Positioner Versions Mechanical feed-back Pneumatic Remote feed-back Local display, Pneumatic Remote feed-back Local display, Electric / Hydraulic Remote feed-back Electric / Hydraulic

More information

Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 [email protected] www.uni-valve.com. Installation and operating manual

Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com. Installation and operating manual Uni-Valve A /S VENTILER & INSTRUMENTER Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 [email protected] www.uni-valve.com UNI-EL Electric actuator Installation and operating manual Remote position

More information

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output. Pump_PT580 Optional PT580-CFG PCM370 Optional DTM96 Buffered Dual Relay Remote Reset Local Display Condition Monitoring System PLC/DCS PT580 Digital Vibration Switch Introduction The PT580 Digital Vibration

More information

Introduction to Process Control Actuators

Introduction to Process Control Actuators 1 Introduction to Process Control Actuators Actuators are the final elements in a control system. They receive a low power command signal and energy input to amplify the command signal as appropriate to

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

THERMAL MANAGEMENT SOLUTIONS

THERMAL MANAGEMENT SOLUTIONS t2000 Series Electronic heat-tracing controller Product Overview /COMMUNICATIONS INTERACE CARRIER REQ TO SEND The DigiTrace heat trace controller is designed to provide the benefits associated with single

More information

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected Niagara Security Overview Niagara Security by Tridium, is an open, web-based security management solution that allows you to manage and monitor your facility anytime, anywhere. Built on Tridium s Niagara

More information

98371000 REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 2011 ELKHART BRASS MFG. CO., INC.

98371000 REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 2011 ELKHART BRASS MFG. CO., INC. 81471067 Electric Monitor Motor Control Panel For use with Model 8394059 SPIT-FIRE Monitor Installation, Operation, and Maintenance Instructions FOR ATEX APPLICATIONS 1302 WEST BEARDSLEY AVENUE P.O. BOX

More information

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES 2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:

More information

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24 1 X CURRENT TRANSFORMER MODEL 546 1.10" I.D. PAGE No 1-38 REV 15DEC00 TERMINAL OPTION LEAD WIRE OPTION 1.10 0 1.20 2.55 3.00 3.47 0.18 x 0.31 SLOT ( 2 PLACES) 8-32 BRASS STUD (2 PLACES) UL1015 #16 AWG LEAD

More information

INDUSTRIAL AUTOMATION EQUIPMENT EDITION 2016. www.elipse-automation.eu

INDUSTRIAL AUTOMATION EQUIPMENT EDITION 2016. www.elipse-automation.eu INDUSTRIAL AUTOMATION EQUIPMENT EDITION 2016 Your partner in an automated industry Our combination of technical know-how, product responsibility and on-time deliveries guarantees you the best WHY CHOOSE

More information

Electronic, Digital and Mechanical Vibration Switches

Electronic, Digital and Mechanical Vibration Switches PT500 Electro-Mechanical Vibration Switch Introduction The PT500 is an economical solution that provides basic vibration protection for rotating reciprocating machines. The PT500 uses an inertia sensitive

More information

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese. Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on

More information

SKR - industry relay

SKR - industry relay SKR - industry relay the universal relay SKR the time module STM the socket The strengths of the SKR industry relay lie in the mature and thoughtout construction. Over-average contact safety and life time,

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

T5000 T000 LCD Digital Fan Coil Thermostat

T5000 T000 LCD Digital Fan Coil Thermostat T5000 T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostats are designed to control heating, cooling, or year round air conditioning unit in Commercial,

More information

Intelligent valve control and monitoring. DSP-PL-001-01 - Intelligent Subsea Positioner

Intelligent valve control and monitoring. DSP-PL-001-01 - Intelligent Subsea Positioner Intelligent valve control and monitoring DSP-PL-001-01 - Intelligent Subsea Positioner Val Controls A/S Intelligent valve control based on the latest know-how concerning digital technology for advanced

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short

More information

Z-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 [email protected]

Z-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 z-trauq@qc.aira.com CURRENT TRANSFORMER MODEL J " x 7" PAGE No 2-2 REV 8DEC00 TERMINAL OPTION LEAD WIRE OPTION 8-2 BRASS SCREW TERMINALS (2 PLACES) SEE NOTE 9 6 9 8 6 Ø 2 9 (4 PLACES) UL 05 #6 AWG LEAD WIRE, STANDARD LENGTH

More information

2.12. page 223 2.12. Products for Explosion hazardous Environment

2.12. page 223 2.12. Products for Explosion hazardous Environment 2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available

More information

Commercial Semi-Instantaneous Water Heaters

Commercial Semi-Instantaneous Water Heaters FEATURES HWI Models A. O. Smith s HWI models are available for operation with steam or boiler water as the energy source. They are factory assembled with components sized, piped and checked at the factory

More information

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8). DS3002 1. General Description This data sheet describes the Modular Power (MP) Electro Hydraulic Power Units, which have been designed to provide an advanced and flexible means of brake control. The MP

More information

( ) = ( ) = {,,, } β ( ), < 1 ( ) + ( ) = ( ) + ( )

( ) = ( ) = {,,, } β ( ), < 1 ( ) + ( ) = ( ) + ( ) { } ( ) = ( ) = {,,, } ( ) β ( ), < 1 ( ) + ( ) = ( ) + ( ) max, ( ) [ ( )] + ( ) [ ( )], [ ( )] [ ( )] = =, ( ) = ( ) = 0 ( ) = ( ) ( ) ( ) =, ( ), ( ) =, ( ), ( ). ln ( ) = ln ( ). + 1 ( ) = ( ) Ω[ (

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

Specifying a Variable Frequency Drive s

Specifying a Variable Frequency Drive s Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

Signature and ISX CM870 Electronics

Signature and ISX CM870 Electronics Signature and ISX CM870 Electronics Cummins West Training Center System Description General Information The Signature and ISX CM870 engine control system is an electronically operated fuel control system

More information

FX07 Field Controller

FX07 Field Controller Product Bulletin FX07 Field Controller Issue Date March 25, 2008 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,

More information

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed. FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and

More information

Absolute Rotary Encoder E6CP

Absolute Rotary Encoder E6CP Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the

More information

Universal Voltage Terminal Photoelectric E3JM

Universal Voltage Terminal Photoelectric E3JM Universal Voltage Terminal Photoelectric Universal AC/DC Photoelectric Sensor with Built-in Timer Easy-to-wire terminal block Built-in timer offers selectable ON-delay, OFF-delay and one-shot Relay or

More information

SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS

SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1 How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module

More information

Actuator-Sensor-Interface

Actuator-Sensor-Interface Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current

More information

Electric Motor Operator for: Gate Valves / Butterfly Valves / Plug Valves M&H VALVE

Electric Motor Operator for: Gate Valves / Butterfly Valves / Plug Valves M&H VALVE Electric Motor Operator for: Gate Valves / Butterfly Valves / Plug Valves M&H VALVE Almost every business day, M&H is assembling and testing valves with Electric Motor operators. Electric motor operator

More information

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC

More information

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject

More information

JAMESBURY QUARTZ LIMIT SWITCH FOR HAZARDOUS AREAS AND GENERAL PURPOSES

JAMESBURY QUARTZ LIMIT SWITCH FOR HAZARDOUS AREAS AND GENERAL PURPOSES JAMESBURY QUARTZ LIMIT SWITCH FOR HAZARDOUS AREAS AND GENERAL PURPOSES The new improved Quartz is available in explosion/flame proof (QX), intrinsically safe and nonincendive (QN) and general purpose (QG)

More information

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large

More information

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution

More information

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) VPS 504 S06 (120 VAC) is: CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter R-15 (Canada) UL

More information

1115 4G SERIES GOVERNOR. 4-20 ma ANALOGUE DIGITAL SPEED SETTING

1115 4G SERIES GOVERNOR. 4-20 ma ANALOGUE DIGITAL SPEED SETTING 1115 4G SERIES GOVERNOR with 4-20 ma ANALOGUE & DIGITAL SPEED SETTING PO Box 28, 9300AA Roden, The Netherlands Tel: +31 505019888 Fax: +31 505013618 E-mail: [email protected] 1115 4G

More information

For Multi-Parameter Meters see mvx

For Multi-Parameter Meters see mvx BULLETIN BULLETIN EM20607 VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up

More information

kajaanipolarox Measure and Control Active Bleaching Chemicals kajaani

kajaanipolarox Measure and Control Active Bleaching Chemicals kajaani kajaanipolarox Measure and Control Active Bleaching Chemicals kajaani Measured Chemical Meas.range [g/l] Cl 2 (chlorine) 0...4 (chlorine dioxide) 0...1.5 ClO - 2 (chlorite) 0...1.5 / SO 2 or NaHSO 3 (chlorine

More information

Series 71, 72, and 76 Modutrol IV Motors

Series 71, 72, and 76 Modutrol IV Motors Series 7, 7, and 76 Modutrol IV Motors PRODUCT DATA FEATURES APPLICATION The Series 7, 7 and 76 Modutrol IV Motors are spring return and nonspring return motors used to control dampers and valves. The

More information

"A" Series Variable Displacement Piston Pumps Single Pump, "OBE" Type Electro-Hydraulic Proportional Pressure & Flow Control Type

A Series Variable Displacement Piston Pumps Single Pump, OBE Type Electro-Hydraulic Proportional Pressure & Flow Control Type Single Pump, "OBE" Type Electro-Hydraulic Proportional & Flow Type Input Signal for Safety valve Input Signal for Flow Amplifier Proportional Solenoid Sensor Valve Piston (S Input Voltage L) Performance

More information

Output torques up to 8000 Nm. General features. Protection. External coating. Working temperature range

Output torques up to 8000 Nm. General features. Protection. External coating. Working temperature range Type series booklet 8521.15/2--10 ACTELEC 31 to 800 (BERNARD) 1/4 turn electric actuators (irreversible reducer with multi -turn electric actuator ACTELEC 31: screw -nut kinematics ACTELEC 200 to 800:

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2494434 (012730_C_000) Issued to: Siemens AG DF CP R&D V 3 Werner-von-Siemens-Strasse 48 Amberg, 92224 GERMANY Attention: Michael Schroeck The products listed below

More information

ACS-30-EU-EMDR-10-MOD

ACS-30-EU-EMDR-10-MOD Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature

More information

Subaru Reference. This reference contains the following information: connector pinouts. connector pinouts

Subaru Reference. This reference contains the following information: connector pinouts. connector pinouts Subject: Source: 1993 2010 Impreza, WRX, and Sti and 2002 07 Outback Sport ABS wiring diagrams, harness routing, and connector locations and pinouts Subaru service manuals This reference contains the following

More information

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) FBR46 SERIES RoHS compliant FEATURES Miniature size About 50% smaller in volume compared with the FBR240 series used mainly in communication equipment.

More information

Pilot Water Heater 6-10 Gallon

Pilot Water Heater 6-10 Gallon Pilot Water Heater 6-10 Gallon First number in matrix refers to illustration number, the second is the part number. 20 1 10 19 21 17 13 18 16 13 14 15 7 6 5 3 12 10 10 9 8 4 11 2 26 28 29 22 23 27 25 23

More information

AXIS PS12 Outdoor Power Supply. Installation Guide

AXIS PS12 Outdoor Power Supply. Installation Guide AXIS PS12 Outdoor Power Supply Installation Guide AXIS PS12 Outdoor Power Supply Connect the AXIS PS12 Outdoor Power Supply This guide provides instructions for connecting and preparing the AXIS PS12

More information

HVAC and Lighting Control Products for Open Building Automation Systems

HVAC and Lighting Control Products for Open Building Automation Systems HVAC and Lighting Control Products for Open Building Automation Systems Distech Controls offers an extensive line of feature-rich and cost effective controllers for building automation, covering HVAC

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5 White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code June 2015 Revision 1.5 Shalhevet Bar-Asher; SolarEdge Technologies, Inc. Bill Brooks, PE; Brooks Engineering LLC

More information

PSR The compact range Description

PSR The compact range Description Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides

More information

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS PT-6000 Power Tower INSTALLATION MANUAL 10.5 9.75 12 22.75 10.75 MAXIMUM SOIL HEIGHT: DO NOT ALLOW FILL TO EXCEED THIS LEVEL! 11.5 4 4 13 Optional PT-BASE for new installations or when previous 2000/6000

More information

DISCONTINUED (2012) VB SERIES 2 POLE 5 A (MEDIUM LOAD CONTROL) POWER RELAY. RoHS compliant

DISCONTINUED (2012) VB SERIES 2 POLE 5 A (MEDIUM LOAD CONTROL) POWER RELAY. RoHS compliant POWER RELAY 2 POLE 5 A (MEDIUM LOAD CONTROL) VB SERIES RoHS compliant FEATURES UL, CSA, VDE, SEV, SEMKO, CQC recognized TV-3 rated Working class: C UL class B (130 C) insulation Type of service: continuous

More information

PARTS LIST DOMESTIC. Eclipse Ergonomic Tilting Braising Pans. BPP-30E, BPP-40E Braising Pans Circa 2003 to Present

PARTS LIST DOMESTIC. Eclipse Ergonomic Tilting Braising Pans. BPP-30E, BPP-40E Braising Pans Circa 2003 to Present IMPORTANT INFORMATION KEEP FOR OPERATOR IMPORTANT INFORMATION PARTS LIST DOMESTIC This manual provides s for: Eclipse Ergonomic Tilting Braising Pans MODELS: BPM-30E, BPM-40E BPP-30E, BPP-40E Braising

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Ω POWEROHM RESISTORS, INC. Braking Resistors for Variable Frequency Drives APPLICATION SELECTING A STANDARD DESIGN CUSTOM RATINGS

Ω POWEROHM RESISTORS, INC. Braking Resistors for Variable Frequency Drives APPLICATION SELECTING A STANDARD DESIGN CUSTOM RATINGS Braking Resistors for Variable Frequency Drives APPLICATION AC variable frequency drives are commonly used with a general purpose AC induction motor to form a reliable variable speed drive system. For

More information

40.3. Control Relays and Timers

40.3. Control Relays and Timers .3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories

More information

Electri-SAFE DataFlo Digital Electronic Positioner Installation, Operation and Maintenance Instructions

Electri-SAFE DataFlo Digital Electronic Positioner Installation, Operation and Maintenance Instructions WCAIM2025 (Part 14944) Electri-SAFE DataFlo Digital Electronic Positioner Installation, Operation and Maintenance Instructions MODELS 15 DP 72 - DataFlo Positioner Mounted On 15-72 Electri-SAFE Actuator

More information

POWER RELAY. JV Series. 1 POLE - 5A/10A Medium Load Control FTR-K1 SERIES FEATURES

POWER RELAY. JV Series. 1 POLE - 5A/10A Medium Load Control FTR-K1 SERIES FEATURES FTR-K1 SERIES POWER RELAY 1 POLE - 5A/10A Medium Load Control JV Series FEATURES UL, CSA, VDE, SEMKO, CQC recognized UL class B (130 C) wire class Low profile and space saving - Height: 12.5 mm - Mounting

More information

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control

More information

Advanced Heat-Tracing Control System

Advanced Heat-Tracing Control System Advanced Heat-Tracing Control System Product Overview Heat-tracing system NGC-30 system Remote configuration and monitoring with Raychem Supervisor software The Raychem NGC-30 is a multi-circuit electronic

More information

Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction

Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction Emergency Operating Instructions Fire Alarm S Priority 2 Alarm Fire Alarm Priority 2 Ack Ack How Acknowledge / View Events Press ACK located under flashing indicar. Repeat operation until all events are

More information

Controller board and power supply for vivimat III systems

Controller board and power supply for vivimat III systems Controller board and power supply for vivimat III systems Ref: VIVIMAT-3.0 The controller board and power supply vivimat 3.0, is the central core of the vivimat III home automation system. The vivimat

More information

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Control- and feedback head for integrated mounting on Robolux valves Type 2036 Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated

More information

AC ADJUSTABLE SPEED DRIVES MICRO SERIES INVERTERS

AC ADJUSTABLE SPEED DRIVES MICRO SERIES INVERTERS MICRO SERIES INVERTERS MICRO SERIES INVERTER DRIVES Full feature, ultra-friendly operation. Programs and reads-out in plain English. Intelligent Power Module-IGBT s with a 16 bit Intel microprocessor.

More information

Y-200 Multi-Stage Sequencer

Y-200 Multi-Stage Sequencer Y-200 Multi-Stage Sequencer Designed for use with single or multiple space heating or hot water supply systems, the Y-200 is offered in 4- and 8-stage configurations and is available loose or factory-mounted

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

How To Drive A Compact Serie 1

How To Drive A Compact Serie 1 Electric lifting cylinder Compact Series Table of Contents Glossary... 2 Compact serie SR 1... 4 Dimension SR 1... 5 Compact Serie SR 1SP... 6 Dimension SR 1SP... 7 Compact Serie SR 5... 8 Dimension SR

More information

StruxureWareTM for Buildings

StruxureWareTM for Buildings StruxureWareTM for Buildings Next generation intelligent Building Management System (ibms) Product Catalogue Make the most of your energy Plan for the future while protecting your past investments. 03

More information

Integrating your automated valves for. Improved process performance

Integrating your automated valves for. Improved process performance Integrating your automated valves for Improved process performance Table of contents StoneL introduction 2 Reliability 4 Technology 5 Customer support 6 Value 7 Integrating your valves 9 Valve communication

More information

Kobelco Extended Warranty Program. www.kobelco-europe.com

Kobelco Extended Warranty Program. www.kobelco-europe.com Kobelco Extended Warranty Program www.kobelco-europe.com Kobelco Extended Warranty is a convenient, value added way to give your Kobelco customers added security and peace of mind. Benefits of the Kobelco

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components

More information

TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR

TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR 3 Phase Air Conditioner Component R2A3**GHR DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER

More information

TSX Micro on support with sockets. Study and programming in PLC language

TSX Micro on support with sockets. Study and programming in PLC language TSX Micro on support with sockets Study and programming in PLC language TSX Micro on support with sockets 1. Presentation of the equipment The "TSX Micro on support with sockets" consists in a PLC TSX

More information

Class 2 transformer (TBT) Low Tension Conform to EN 60742. A LED turns ON when the current exceeds 1 A at the 14V output connector

Class 2 transformer (TBT) Low Tension Conform to EN 60742. A LED turns ON when the current exceeds 1 A at the 14V output connector Technical notice TECHNICAL CHARACTERISTICS Power Class 2 transformer (TBT) Low Tension Conform to EN 60742 Rechargeable battery 16 Vac, 50-60Hz 50 Va min. 250 Va max 12 V, 7AH Protection A LED turns ON

More information

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel. +45 7547 0600 [email protected] www.valcontrols.

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel. +45 7547 0600 vc@valcontrols.com www.valcontrols. HARDWARE MANUAL Ixx24-A 1/20 Table of contents 1 General... 3 1.1 Safety instructions... 3 1.2 Environment... 3 1.3 Mounting and dimension... 3 2 Communication... 4 2.1 Control loop AI0 and Transmitter

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed in a rigid metallic conduit system for surface mounting adjacent

More information

GUE, GUB Junction Boxes

GUE, GUB Junction Boxes E GUE, GUB Junction Boxes Cl. I, Div. & 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 4*, BCD, 9EFG Ex d IIC T6, IP66 Ex d IIC, IP66, ATEX certified Explosionproof

More information