Electri-SAFE DataFlo Digital Electronic Positioner Installation, Operation and Maintenance Instructions
|
|
|
- Eugenia Mathews
- 9 years ago
- Views:
Transcription
1 WCAIM2025 (Part 14944) Electri-SAFE DataFlo Digital Electronic Positioner Installation, Operation and Maintenance Instructions MODELS 15 DP 72 - DataFlo Positioner Mounted On Electri-SAFE Actuator 20 DP 72 - DataFlo Positioner Mounted On Electri-SAFE Actuator Inputs DP - 1K (120 A) DP - 10 (120 A) DP - 13 (120 A) DP - 5V (120 A) DP - 1 (120 A) DP- XV (120 A) DP - 4 (120 A) 1000 ohm Resistance Input 10 to 50 milliampere Input 135 ohm Resistance Input 0 to 5 VDC Input 1 to 5 milliampere Input 0 to 10 VDC Input Voltages 120A VAC Power Circuits 4 to 20 milliampere Input DESCRIPTION OF ACTUATOR GENERAL This Installation, Operation, and Maintenance manual makes reference to Valve closed and open positions. When the Electri-SAFE actuator is mounted with positioner housing up, and the actuator mounted inline with the valve piping. Then the CLOSED POSITION = FULL CLOCKWISE (CW), and the OPEN POSITION = FULL COUNTERCLOCKWISE (CCW). DESCRIPTION /McCANNA Series DP 72 actuators are electrohydraulic quarter-turn valve actuators which can be set to hold positions between full closed and full open. These units feature a normally open solenoid valve which returns the actuator to its initial, or fail-safe, position when electrical power is removed from the actuator. The actuator design utilizes a double-rack, single-pinion concept, with each rack integrally cast to a piston. Both pistons are supported and centered by large, stainless steel guide rods. A /McCANNA Electri-SAFE Electronic Positioning Circuit board is used to set positions between full closed and full open. It is mounted in the positioning housing attached to the top of the actuator. The positioner board has many programmable features and custom settings. These are outlined in the Technical and Programming Reference Manual. ENVIRONMENTAL CONSIDERATIONS CAUTION: The Electri-SAFE DataFlo Digital Electronic Positioner is sensitive to electrical noise on signal or supply lines and in the environment. For maximum positioner sensitivity, the electrical noise level should be as low as possible. Follow installation, calibration and adjustment guidelines carefully and use shielded wire for all signal wiring. Flowserve recommends that all products that must be stored prior to installation be stored indoors, in an environment suitable for human occupancy. Do not store product in areas where exposure to relative humidity above 85%, acid or alkali fumes, radiation above normal background, ultraviolet light, or temperatures above 120 F or below 40 F may occur. Do not store within 50 feet of any source of ozone. Temperature and humidity are the two most important factors that determine the usefulness and life of electronic equipment. Temperature Operating solid-state electronic equipment near or beyond its high temperature rating is the primary cause for most failures. It is, therefore, very important that the user be aware of and take into consideration, factors that affect the temperature at which the electronic circuits will operate. Operating an electronic device at or below its low temperature rating generally results in a unit operating poorly or not at all, but it will usually resume normal operation as soon as rated operating temperatures are reached. Low temperature problems can be easily cured by addition of a thermostatically controlled heater in the positioner housing.
2 The Worcester/McCANNA DataFlo Digital Electronic Positioner is rated for operation between -40 F (with heater and thermostat) and 150 F. Humidity Most electronic equipment has a reasonable degree of inherent humidity protection and additional protection is supplied by the manufacturer, in the form of moisture-proofing and fungicide coatings. Such protection, and the 3 to 4 watts of heat generated by the circuit board assembly, will generally suffice for environments where the average relative humidity is in the area of 80% or less and ambient temperatures are in the order of 70 F average. Where relative humidity is consistently 80 to 90% and the ambient temperature is subject to large variations, consideration should be given to installing a heater and thermostat option in the enclosure. The heater should not increase the enclosure temperature to the point where the circuit board assembly s temperature rating of 150 F is exceeded. In those instances where the internal heater would bring the circuit board s operating temperature near or above its maximum rating, the user might consider purging the enclosure with a cool, dry gas. The initial costs can usually be paid off quickly in the form of greatly extended equipment life, low maintenance needs, and much less process downtime. Input Circuit Noise Protection Shielded wiring should be used as conductors for all signal input circuit wiring regardless of length. The shields should never be used in place of one of the input wires, and the shields should be grounded to equipment housings at one end of the wiring run only. Grounding both ends of shielding can eliminate the shielding benefits because of current ground loops. If two or more shielded cables come to the Positioner from different locations, ground the shields at the Positioner. a WARNING: SERIES 72 ACTUATORS ARE ELECTRO-MECHANICAL DEVICES SUBJECT TO NORMAL WEAR AND TEAR. ACTUATOR LIFE IS DEPENDENT UPON APPLICATION AND ENVIRONMENTAL CONDITIONS. IF APPLIED IN HAZARDOUS SERVICES SUCH AS, BUT NOT LIMITED TO, MEDIA TEMPERATURE EXTREMES, TOXINS, FLAMMABLE, OR OTHER SERVICES WHERE IMPROPER OR INCOMPLETE OPERATION COULD PRODUCE A SAFETY HAZARD, IT IS INCUMBENT UPON THE SYSTEM DESIGNER AND THE USER TO PROVIDE PROPER WARNING DEVICES SUCH AS TEMPERATURE SENSORS, OXYGEN SENSORS AND FLOW SENSORS. INSTALLATION Mechanical Assembly of Actuator to a or McCANNA Valve: The Series DP 72 actuator assembly is in its full clockwise position when no electrical power is supplied. Applying electrical power and a position input signal will cause the actuator to rotate in a counterclockwise rotation. The Series DP 72 actuator is a heavy unit. Make sure that the unit and the valve it is mounted to is supported properly in accordance with good piping practices. When mounting the actuator to a non- Worcester/McCANNA valve, please refer to the manufacturer s recommendations for installation and operation. The actuator is normally installed with its major axis parallel to the pipe line (this is mandatory when mounting actuator to 90 V1 diverter/three-way (D44 & T44) valves and CPT valves). The actuator can be oriented above, beside, or below the valve without affecting its operation. Actuators come with an ISO locating ring used for optional ISO mounting. For mounting to 818/828 Series valves, insert ISO locating ring into groove on bottom of actuator before attaching to bracket. Note: Ring can be permanently held in groove by applying Loctite to ring before inserting in groove. Determine mode of operation desired (normally open or normally closed) of the valve. Determine desired quadrant for bracket attachment and direction of mounting of actuator (in-line or cross-line). Fail-Safe Actuators - The normal method of mounting is to have the actuator in-line with the pipeline and the valve and actuator in the power off/fail-closed position. For FAIL-OPEN cross-line operation, rotate the valve ball and stem 90, so coupling lines up with actuator shaft. Mount actuator cross line to pipe line. For FAIL-OPEN in-line operation using an in-line coupling, rotate the valve ball and stem 90, so coupling lines up with actuator shaft. Mount actuator in-line with the pipeline. Attach mounting bracket to actuator using four (4) cap screws and lockwashers provided in mounting kit. To avoid any damage to the Series 72 aluminum actuator body, ONLY the proper length screws supplied with the mounting kit should be used. For small size top-mount style valves, attach the mounting bracket such that bracket nameplate will be to the side of the valve. Attach bracket/actuator assembly to valve as follows: CAUTION: Ball valves can trap pressurized media in the cavity. If it is necessary to remove any valve body bolts, stem nuts, or remove valve from the line, and if the valve is or has been in operation, make sure there is NO pressure to or in the valve and operate valve one full cycle. It is not necessary to remove any valve body bolts or remove valve from line in order to mount actuator on valve models: 44 ( 1 /4"-2"), 45 (2 1 /2"-4"), 51/52 ( 1 /2"-4"), 151/301 (3"-4"), 59 ( 1 /4"-3"), WK70/WK74 and H71 ( 1 /2"-2"), 818/828 (2"-3"), 82/83 ( 1 /2"-3"), 94 ( 1 /2"-4"): Rotate valve ball and stem to position necessary to achieve desired operation. If any valve information is marked on stop plate or handle, it will be necessary to transfer this information to the bracket nameplate. 2 Electri-SAFE DataFlo Digital Electronic Positioner WCAIM2025
3 For 1 /4"-2" 44, 1 /2"-2" WK70/WK74, 1 /4"-1 1 /2" 59 and 1 /2"-1 1 /2" H71 series top-mount style valves and 1 /2"-2" 51/52 and 1 /2"-1 1 /2" 82/83 Series valves with high-cycle stem packing as standard, remove handle nut, lock washer, handle, separate stop plate (if any), retaining nut and stop pin(s) and discard. Add the two additional Belleville washers provided with the mounting kit. Install with their larger diameter sides touching each other. Add the self-locking nut to the stem and tighten while holding the stem flats with wrench. Tighten until Belleville washers are flat, the nut will bottom, and then back nut off 1 /3 of a turn. The two additional Belleville washers and the self-locking nut are included in the mounting kit. CAUTION: The self-locking stem nut is difficult to tighten, and must fully flatten Belleville washers before backing off. For 2" 59, H71, 82/83, and 2 1 /2" 45, 82/83 series valves, and valves 3" and larger with square stem, remove handle assembly, retaining nut, stop and stop screws. Replace with valve stem spacer and replace retaining nut. If the valve has graphite stem packing, replace the valve stem spacer with two Belleville washers, and replace retaining nut. Belleville washers are installed with their larger diameter sides touching each other. Do not use stem spacer when Belleville washers are used. Using a wrench to prevent stem from turning, tighten retaining nut until stem packing is fully compressed or Bellevilles, if used, are fully flattened, then back off nut 1 /6 turn. Excessive tightening causes higher torque and shorter seal life. Large valves with V51 high cycle stem packing option installed (identified by two Belleville washers installed and handle assembly, stop, and stop screws removed), and 818/828 Series valves do not require stem area disassembly. For 1 /2"-2" 94 valves, remove handle (if any). Do not remove gland plate or gland bolts. For 3"-4" 94 and 2"-3" E818/828 valves, remove handle assembly, stop, and spacer (if any). Do not remove gland plate or gland bolts. For 2"-3" 818/828 valves, remove handle assembly, locking plates and hardware, and stop screw (if any). Do not remove stop plate. Center coupling on valve stem. Lower mounting bracket/actuator assembly over coupling and onto valve, making sure that male actuator shaft engages slot in coupling. Secure bracket to valve using cap screws and lockwashers, or bolts and nuts provided in mounting kit. Tighten securely. For small size top-mount style valves, bracket nameplate will be to side of valve. Install set screws (if any) in the coupling and tighten securely. Electrical Wiring of Actuator and Positioner The actuator housing contains power and switch terminals for field wiring. The terminal strip is for incoming power connectors and optional limit switch wiring for indication of actuator position. Users can use these optional switches for wiring to their indicating lights and/or logic. See wiring label on inside of cover and/or wiring diagram below for power connections. See wiring label on inside of cover and/or technical reference manual for optional switch wiring. All electrical connections and calibration functions should be performed by a qualified individual who is trained in the installation and operation of electrical equipment. All wiring to terminal strips shall be inserted only to mid-point of terminal strip. 120 VOLT AC POWER - minimum required power is 110 volts AC, maximum is 130 volts AC. NOTE: This table shows the minimum rating to prevent inrush current from blowing the fuse. Minimum Fuse Rating for Over Current Protection Actuator Size Voltage Fuse Rating VAC 10 A VAC 10 A Loosen the 12 captive screws and remove the flat cover and gasket on the conduit connection end of the actuator. Remove the red plastic conduit connection plug and attach a suitable conduit pipe to the 3 /4" NPT conduit connection on the actuator limit switch. NOTE: Connections and seals are to meet specifications listed in the National Electrical Code Chapter 5 for the environment in which the actuator will be installed. Use #18 awg wire as a minimum wire size. Attach the AC neutral wire (white) to the terminal strip location labeled 7 and the AC hot wire (black) to the terminal strip location labeled 8. Attach the ground wire to the green colored grounding screw in the actuator housing. Replace the gasket and flat cover, and tighten the 12 captive screws. INPUT SIGNAL The positioner housing contains terminals for field wiring of input signals to operate the actuator. The Digital Positioner signal input circuit is protected by a 1 /16 amp fuse, F1. Location of the fuse is shown on the Digital Electronic Positioner Circuit Board photograph in the Technical Reference Manual. See the Technical Reference Manual for additional detailed input circuit specifications. NOTE: After input signal connections have been made, securely tighten all terminal screws. Keep wiring away from all rotating parts and ensure wires are not pinched when the covers are installed. WCAIM2025 Electri-SAFE DataFlo Digital Electronic Positioner 3
4 For all Signal Input/Output Connections: Remove the red plastic conduit connection plug and attach a suitable conduit pipe to the 3 /4" NPT conduit connection to the positioner housing. NOTE: Connections and seals are to meet specifications listed in the National Electrical Code Chapter 5 for the environment the actuator will be installed in. Loosen the retained housing cover screws and remove the top cover of the positioner housing. DP72-1, DP72-4, DP72-10 (milliamp Input Signal for Digital Positioner) This Positioner is available for use with the standard milliamp signals: 1 to 5, 4 to 20, and 10 to 50 milliamp. The Positioner board is factory calibrated for one of the three milliamp signal ranges. Comparison of resistance measurements made at terminals B and C against the resistances shown below provides a quick way to determine the milliamp range for which a particular board is calibrated. If fuse F1 is blown, an open circuit will be indicated. 1 to 5 milliamp models approximately 1000 ohms 4 to 20 milliamp models approximately 220 ohms 10 to 50 milliamp models approximately 100 ohms Connect the more positive (+) or High signal lead to positioner terminal B. See wiring label on inside of positioner cover, and/or in appendix of technical reference manual, and/or wiring diagram on following page. Connect the less positive (-) or Common lead to positioner terminal C. Connect one end of the shield wire to the positioner housing. Note that only one end of the shield wire should be connected to a grounded housing. Do not replace the positioner cover until the unit has been calibrated and the unit is operational. See the paragraph for Calibration and Adjustment on the next page. DP72-13, DP72-1K (Potentiometer Input for Digital Positioner) Potentiometer input circuit boards are made in two versions, one for low resistance command circuits - DP ohms nominal, and one for high resistance command circuits - DP72-1K 1000 ohms nominal. NOTE: The Input Potentiometer is not the Feedback Potentiometer, but is an additional Potentiometer provided by and externally located by the end user. Connect the signal leads to positioner terminals A, B and C. See wiring label on inside of positioner cover, and/or in appendix of technical reference manual, and/or wiring diagram on page 5. A Close command is generated when the potentiometer is rotated to its full CCW position, and an Open command when the potentiometer is rotated to its full CW position. If the command signal is derived from other than a rotary pot, it is only necessary to keep in mind that a Closed (full CW) valve is called for when the command potentiometer presents the least resistance between terminals B and C and the most resistance between terminals A and B. A full Open (full CCW) valve would be the reverse condition; the least resistance between terminals A and B and the most resistance between terminals B and C. If the Command potentiometer is reasonably linear, the actuator/valve will be approximately 50% open when the potentiometer shaft is halfway through its travel and the resistance s between terminals C to B and B to A are equal. If applicable, connect one end of the shield wire to the positioner housing ground screw. Note that only one end of the shield wire should be connected to a ground source. 4 Electri-SAFE DataFlo Digital Electronic Positioner WCAIM2025
5 Do not replace the positioner cover until the unit has been calibrated and the unit is operational. See the paragraph for Calibration and Adjustment. DP72-5V, DP72-XV- Direct Voltage Input Signal for Digital Positioner This Positioner is available for use with the standard direct voltage signals: 0 to 5 VDC or 0 to 10 VDC. The Positioner board is factory calibrated for one of these two signal ranges and field changes are not advised. Comparison of resistance measurements made at terminals B and C against the resistances shown below provides a quick way to determine the voltage range for which a particular board is calibrated. If fuse F1 is blown, an open circuit will be indicated. 0 to 5 volt DC models approximately 800 ohms 0 to 10 volt DC models approximately 1100 ohms Connect the more positive (+) or High signal lead to positioner terminal B. See wiring label on inside of positioner cover, and/or in appendix of technical reference manual, and/or wiring diagram below. Connect the less positive (-) or Common lead to positioner terminal C. Connect one end of the shield wire to the positioner housing ground screw. Note that only one end of the shield wire should be connected to a grounded housing. Do not replace the positioner cover until the unit has been calibrated and the unit is operational. See the paragraph for Calibration and Adjustment below. CALIBRATION AND ADJUSTMENT When properly adjusted, the actuator will stop at the full CCW and full CW positions as a result of having reached one of the respective limits of the input signal span. The full CCW over travel limit Switch will be used only as a backup to stop the actuator pump motor should a failure of an electronic component occur. Adjustment of Over-travel Limit Switch The Positioner has been shipped with a limit switch factory calibrated to stop the actuator in the full CCW position (approx. 92 ). It is located in the actuator housing, behind the flat cover. If it has been determined that the limit switch requires adjustment, perform the adjustment as follows: NOTE: Be very careful when adjusting the switch. It can be damaged by the actuator switch probe if the switch is adjusted (tightened) too far in toward the probe. If in doubt of switch position, loosen (back out) the switch adjustment screw to its loose limit before performing the following steps. If not already done, remove the actuator and positioner housing covers. When power is first applied, the unit will be in the Run Mode. The positioner display should be flashing between POS and a number between 0 and 100. There are three switches (keys) on the positioner circuit board which are labeled SEL(black) for select, DN(white) for down, and UP(white) for up. These are the keys used to calibrate, program, and position the Digital Positioner Board locally. On the positioner board, simultaneously press the SEL and UP keys for three seconds to enter the Manual Mode. The display should alternate between POS and 0.0. WCAIM2025 Electri-SAFE DataFlo Digital Electronic Positioner 5
6 Press and hold the UP key until the actuator goes full CCW and stops moving. The actuator should be full CCW, and there should be no motor noise. If the motor continues to run, turn the limit switch adjustment screw clockwise until the motor stops running. Turn the adjustment screw clockwise an additional 1 /4 turn to set the switch. Verify the switch setting by: Press the DN key to rotate the actuator shaft about 20 degrees CW. Turn the limit switch adjusting screw counterclockwise 1 /2 turn. Press and hold the UP key until the actuator shaft rotates to full CCW and stops moving. If the actuator is not at full open: Press the DN key to rotate the actuator shaft about 20 degrees CW. Turn the limit switch adjusting screw counterclockwise 1 /2 turn. Press and hold the UP key until the actuator shaft rotates to full CCW and stops moving. Repeat until the actuator is full open and there is no motor noise. The actuator shaft must travel a couple of degrees beyond the 90 degree full CCW position for the Positioner to control the full range of operation. Place a straightedge along the flats on the actuator shaft to verify that the actuator has gone past the 90 degree position when stopped by the limit switch. To return to the RUN mode, press and hold the SEL key for three to five seconds. Calibration Procedures for Positioner See the Technical Reference Manual for more detailed programming information. When power is first applied the unit will be in the Run Mode. The display should be flashing between POS and a number between 0 and 100. Simultaneously press and hold the SEL and DN switches (keys) for three seconds to enter the calibration mode. When first entering the Calibration Mode, CAL will be displayed for two seconds and the security code will be checked. If the required security code is not zero ( 0000 ), the display will begin alternating between code and Enter the security code as described in paragraph and per paragraph of the Technical Reference Manual. If the required security code is zero, it will not need to be entered by the user, i.e., it will be bypassed and the display will automatically flash SEtL, and you can skip to paragraph b). Note: if the security code is forgotten, the special number 4800 can be used to gain entry. However, this number will now be the new security code and if another code number is still desired, it will have to be reprogrammed. a. If and after a security code has been entered, press and release SEL to accept code. The display will now flash SEtL and a value. b. Simultaneously press and release the SEL and UP keys, then adjust input signal to lower input value, e.g., 4 ma. Press and release SEL to lock in value. c. Press and release the DN key, the display will now flash SEtU and a value. Simultaneously press and release SEL and UP, and then adjust input signal to higher input value, e.g., 20 ma. Press and release SEL to lock value. d. Press and release DN, the display will now flash PoC and a number between 0.0 and 5.0. Simultaneously press and release SEL and UP. Rotate the actuator to the full clockwise CW position by pressing and holding the DN key. Release the DN key when full rotation has been achieved. Important: Be careful not to go past the CW 0 degree position. (Position a straightedge along the flats on the positioner shaft to verify the shaft position). The display should read between.200 and.400. If not: rotate the face gear located on the positioner shaft (that drives the potentiometer) until you read between.200 and.400. The gear is held in place by means of a friction fit and a snap ring. No tools are needed nor is it necessary to loosen or remove the snap ring to move the gear. Steady gentle finger pressure will move the gear to allow you to adjust the feedback pot. Press and release SEL to lock in value. e. Press and release the DN key, the display will now flash PoCC and the feedback voltage value. To edit, simultaneously press and release SEL and UP switches then: Use the UP switch to manually rotate the actuator to the CCW 90 position. (Do not go past 90 - Place a ruler on the positioner shaft flat for indication.) If the shaft rotates past 90, use the DOWN switch to bring the shaft back to the 90 position. Press the SEL switch to lock in the 90 feedback reading. Control returns to the Calibration menu. f. Press and release the DN key, the display will now flash Cyt and a cycle time reading. Simultaneously press and release the SEL and UP keys. At this time the actuator will perform one cycle to measure its cycle time displaying PoC as the actuator travels to the full CW position and PoCC for the CCW position. g. To return to the RUN mode, press and hold the SEL key for three to five seconds. OPERATION When power is applied to the positioner, it enters the Run Mode and begins controlling the valve position according to its setpoint input. The valve position is controlled to within the dead band setting of setpoint. See the discussion on dead band in the Technical Reference Manual. Programmable parameters are available to control the behavior of the positioner. Parameters are used to detect alarm conditions, to change the setpoint curve, to set positioning precision and other functions. An RS485 connector located on circuit board is supplied for computer interface to program all parameters. See the Technical Reference Manual for further reference. 6 Electri-SAFE DataFlo Digital Electronic Positioner WCAIM2025
7 The positioner normally receives the setpoint signal from an external source. However, the positioner can also operate with an operator entered setpoint by using the Manual Setpoint Mode, described in the Technical Reference Manual. As the positioner controls valve position, various alarm conditions can occur. The positioner contains a circuit that will provide an opticallyisolated alarm output that will activate when any alarm occurs. This output can be used simply for operator notification or as a signal to other processes. Parameters can be programmed to take an action when certain alarms occur. The alarm state can be viewed on the positioner display. See the Technical Reference Manual for further reference. An optional current output module can be used to indicate shaft position. A programmable parameter can be set to specify the output current range as either 4 to 20 ma or 0 to 20 ma. See the Technical Reference Manual for further reference. MAINTENANCE GENERAL INFORMATION A properly functioning Electri-SAFE Positioner will always be in the full CW position whenever power is removed from terminals 7 and 8 in the actuator housing. If a problem cannot be solved, the unit should be returned to the factory for service. All electrical troubleshooting should be performed by a licensed electrician or qualified electrical technician. Initially check for loose wiring inside both electrical housings. Check wiring against figures located in the Technical Reference Manual. ELECTRI-SAFE TROUBLESHOOTING For troubleshooting and diagnostics, see the Technical Reference Manual. WCAIM2025 Electri-SAFE DataFlo Digital Electronic Positioner 7
8 Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flowserve product is designed to perform its intended function safely during its useful life. However, the purchaser or user of Flowserve products should be aware that Flowserve products might be used in numerous applications under a wide variety of industrial service conditions. Although Flowserve can (and often does) provide general guidelines, it cannot provide specific data and warnings for all possible applications. The purchaser/user must therefore assume the ultimate responsibility for the proper sizing and selection, installation, operation, and maintenance of Flowserve products. The purchaser/user should read and understand the Installation Operation Maintenance (IOM) instructions included with the product, and train its employees and contractors in the safe use of Flowserve products in connection with the specific application. While the information and specifications contained in this literature are believed to be accurate, they are supplied for informative purposes only and should not be considered certified or as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construed as a warranty or guarantee, express or implied, regarding any matter with respect to this product. Because Flowserve is continually improving and upgrading its product design, the specifications, dimensions and information contained herein are subject to change without notice. Should any question arise concerning these provisions, the purchaser/user should contact Flowserve Corporation at any one of its worldwide operations or offices. For more information about Flowserve Corporation, contact or call USA FLOWSERVE CORPORATION FLOW CONTROL DIVISION 1978 Foreman Drive Cookeville, Tennessee USA Phone: Facsimile: Flowserve Corporation, Irving, Texas, USA. Flowserve and are registered trademarks of Flowserve Corporation. WCAIM2025 9/03 Printed in USA
Experience In Motion. Valtek Spring Cylinder Linear Actuators
Experience In Motion Valtek Spring Cylinder Linear Actuators Valtek Spring Cylinder Linear Actuator Flowserve spring cylinder linear actuators are powerful, compact, high-performance pneumatic actuators
I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.
FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and
Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation
Instruction Manual 1052 Size 20 Actuator (F & G) Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation Contents Introduction... 1 Scope of manual... 1 Description... 1 Specifications...
Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual
0 P a g e H.264 Color or Day/Night SurroundVideo Installation Manual Inside the box: A. Arecont Vision SurroundVideo camera B. Mounting template C. RJ45 female to female coupler D. Hex key E. Security
JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator
JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator The Janus Pantheon mini operator does not typically require the provision of any additional site requirements other than
Stainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...
OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS INTRODUCTION...1 Scope...1 Description...1 Valve Identification...2 1.0 VALVE INSTALLATION...2 2.0 VALVE MAINTENANCE...3 Actuator Disassembly...3
Powers Controls TH 192 HC Heating/Cooling Room Thermostat
Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional
Part I - Installation
400 Series Pressure and Differential Pressure Switches Types: H400, H402, H403, H400K, H402K, J400, J402, J403, J400K, J402K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read
Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family
Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Part of the Kiva Lighting Family Custom Lighting and Fans Since 1992 1312 12th St NW Albuquerque,
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions
4057250/8 IM-P405-16 AB Issue 8 ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions 1 General safety information 2 General product information 3 Installation 4 Operation
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE Cable Processor Module overview WARNING! When tipping the Cable Processor Module back, (after removing the toggle arm pin), use extreme caution not to drop
VX 2400 Dimmer User's Manual
TM VX 2400 Dimmer User's Manual 21-2119C Manual Revision 1.01 Software Version 1.0 10 March 1994 Table of Contents 1. General Description...3 1.1. Standard Features:...3 2. Installing Options...4 2.1.
Powers Controls TH 192 S Single Temperature Room Thermostat
Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
Worcester DS/DM Series UltraSwitch Switch box
Worcester DS/DM Series UltraSwitch Switch box Features DS/DM Series Ultraswitch Description The DS/DM Series UltraSwich from Flowserve Worcester provides cost efficient, accurate and reliable position
1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.
1 1. SAFETY RULES 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning. 2. All wiring must be in accordance with the National
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information
Safety Safety Is Your Responsibility DANGER To avoid personal injury or death, carefully read and understand all instructions pertaining to the Anthony Liftgates product. Do not attempt to install, operate,
Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat
Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual
INSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
! WARNING. Before using product, read and understand instructions.
McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes
Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)
TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) WARNING - HIGH VOLTAGE AC electrical circuits are connected to this heater. Do not attempt any service work on the
1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT".
1 1. SAFETY RULES 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning. 2. All wiring must be in accordance with the National
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
Service Information CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS NOTE
Service Information Calibration & Adjustments CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS Part Number DYN1-10752-000-0-12/24 DYN1-10752-001-0-12/24* DYN1-10753-000-0-12/24
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions
TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions TRACETEK TraceTek TTDM Replacement Parts General Information These instructions detail the steps to
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
GPS AutoSteer System Installation Manual
GPS AutoSteer System Installation Manual Supported Vehicles John Deere Sprayers 4720 4630 4730 4830 AutoTrac Ready PN: 602-0227-01-A LEGAL DISCLAIMER Note: Read and follow ALL instructions in this manual
Electric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12" DUAL BEVEL COMPOUND MITER SAW B27A
PAGE 1 OF 6 BASE ASSEMBLY 00 0 EXAMPLE: Component Parts (Small #) Are Included When Ordering The Assembly (Large #). SPECIFY CATALOG NO. AND NO. WHEN ORDERING PARTS 1 02-80-0050 Thrust Bearing (1) 2 05-80-0510
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive
Specifying a Variable Frequency Drive s
Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators
M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators Product Bulletin Code No. LIT-1201742 Issued February 12, 2015 The M9102 and M9104 Series Actuators are directmount,
Vogt Valves The Connection Bulletin for Extended Body Forged Steel Valves Welded Bonnet, Bolted Bonnet, Class 800 & Class 1500 CB 22
The Connection Bulletin for Extended Body Forged Steel Valves Welded Bonnet, Bolted Bonnet, Class 800 & Class 1500 CB 22 Extended Body Forged Steel Valves An extended body gate valve specifically designed
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
A descriptive definition of valve actuators
A descriptive definition of valve actuators Abstract A valve actuator is any device that utilizes a source of power to operate a valve. This source of power can be a human being working a manual gearbox
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011
WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers Installation Guide February, 2011 Pace Scientific Inc www.pace-sci.com Tel: 704-799-0688 [email protected] 1 Disclaimer The following warranty
A99B Series Temperature Sensors
FANs 125, 121, 930, 930.5 Product/Technical Bulletin A99 Issue Date 0615 A99B Series Temperature s The A99B Series Temperature s are passive PTC (Positive Temperature Coefficient) sensors. The A99B sensors
EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.
EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board. This Troubleshooting Guide covers the electric coolant valve and control
Fuel Injection Pump, Rotary (005-014)
Fuel Injection Pump, Rotary View Related Topic Page 1 of 30 Fuel Injection Pump, Rotary (005-014) Table of Contents Summary General Information Preparatory Steps Remove Front Gear Train Rear Gear Train
Digi-Motor Installation Guide
Digi-Motor Installation Guide Installation Video...located at marsdelivers.com Digi-Motor Installation Guide Digi-Motor For technical assistance with your Azure Digi-Motor, call the MARS technical support
TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output
133-683 JUNE 28, 2006 TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output DESCRIPTION APPLICATION The Fireye 65UV5-1004 flame scanner is a microprocessor based flame
IF IT FLOWS THE BOWIE PUMP CAN PUMP IT
IF IT FLOWS THE BOWIE PUMP CAN PUMP IT Bowie Industries, Inc. Bowie, TX 76230 USA Page 1 Bowie Pumps Manual General Pump Information..Page 2 300 Series Pumps.. Page 5 400 Series Pumps.Page 11 500 Series
with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.
B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary
FCD MMASS0008-00 (Part V400) AN ISO 9001 REGISTERED COMPANY. Ball Valve Actuator Selection
FCD MMASS0008-00 (Part V400) AN ISO 9001 REGISTERED COMPANY Ball Valve Actuator Selection Automation of McCANNA Ball Valves Increasing labor rates throughout the world are just one reason why valve automation
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
IOM SERIES 820-E/P Electro-Pneumatic Positioner
FLUID CONTROL DIVISION Parker Hannifin Corporation 95 Edgewood Avenue New Britain, CT 06051 Telephone (860) 827-2300 IOM SERIES 820-E/P Electro-Pneumatic Positioner INSTALLATION, OPERATING & MAINTENANCE
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html TECHNICAL SERVICE DEPARTMENT Effective October 2007, we transitioned to the White Rodgers (Intelli-Vent TM )Thermostat Control for
* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2
COMMERCIAL INSTALL GUIDE 2 Contents How to Use This Guide: The first section of this guide is designed to assist you with the installation of your DECK Monitoring hardware. The revenue grade meter and
MP8000 Series Pneumatic Valve Actuators
14-1161- 9, Rev. A Technical Bulletin MP8000 Issue Date March 2016 MP8000 Series Pneumatic Valve Actuators Pre-Assembly Details Page 3 MP8000 Actuator Components 3 Tools Required to Assemble an MP8000
INSTALLATION & OPERATING INSTRUCTIONS
INSTALLATION & OPERATING INSTRUCTIONS WARNING RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND-FAULT CIRCUIT-INTERRUPTER. THE UNIT SHOULD BE INSTALLED BY A QUALIFIED SERVICE REPRESENTATIVE.
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Electric Vacuum Pump Kit 28146 Thank you for choosing STAINLESS STEEL BRAKES CORPORATION for your braking needs. Pleases take the time to read and carefully follow these instructions
TECHNICAL BULLETIN. Kämmer LinedFlow - 132000 Corrosive Application Valves. Experience In Motion FCD KMENTB3221-01 04/12
TECHNICAL BULLETIN Kämmer LinedFlow - 132000 Corrosive Application Valves FCD KMENTB3221-01 04/12 Experience In Motion Description ¼-inch NPT test port Large guided stem area Bellows seal eliminates stem
TorqPlus TM Electric Valve Actuators and Controls
TorqPlus TM Electric Valve Actuators and Controls Torque 150 IN/LB 600 IN/LB The Engineered Solution Bettis TorqPlus quality line of electric actuators are designed for quarter turn applications ball,
S03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators
S, S Series Low-Torque Spring- Return Direct-Coupled Actuators S, S, S, S, S, S INSTALLATION AND OPERATING INSTRUCTIONS S, S Series Low-Torque Spring-Return Direct-Coupled Actuators (DCA) are used for
TC-9102 Series Surface Mount Temperature Controllers
TC-9102 Series Surface Mount Temperature Controllers General Description & Applications The TC-9102 Series Temperature Controller offers a versatile solution for a wide variety of applications that may
60" TulleTM. Instruction Manual. A Kichler Select ceiling fan
60" TulleTM A Kichler Select ceiling fan Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Customer Service 866.558.5706 8:30 AM to 5:00 PM EST, Monday - Friday
HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install
HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install Carrier-Grade Instructions HP Part Number: AM275-9001A Published: July 2012 Edition: 3 Copyright 2009, 2012 Hewlett-Packard Development Company,
TR21, TR22, TR23, and TR24 Wall Modules
TR21, TR22, TR23, and TR24 Wall Modules FEATURES INSTALLATI INSTRUCTIS The TR21, TR22, TR23, and TR24 family of wall modules include: Models with setpoint adjustment. Models with humidity output. Models
CortezTM A Kichler Décor Ceiling Fan
CortezTM A Kichler Décor Ceiling Fan Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Customer Service 866.558.5706 8:30 AM to 5:00 PM EST, Monday - Friday Instruction
Installation Instructions
0.1.2....6.7..9 1 0.1.2....6.7..9 1 Installation Instructions Quick-Mount Visual Instructions for Mechanical Installation Quick-Mount Visual Instructions 1. Rotate the damper to its fail-safe position.
Reliance DuraStar ORDINARY LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS
STORAGE and HANDLING The LED Illuminator meets or exceeds all applicable specifications when shipped from the factory. All units should be inspected upon receipt to ensure that no damage has been incurred
ATL Fuel Level Sender Probes
T E C H N I C A L S P E C I F I C A T I O N The ATL EL-AD-151 (Resistance Output) and EL-AD-152 (Voltage Output) Fuel Level Senders are highly advanced sensors for continuously measuring the contents of
RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions
Heat-Tracing Remote Monitoring Module for the NGC Control System Installation Instructions Tools Required 3 mm slotted screwdriver 3/8 hex key (for -4X only) Approvals Nonhazardous locations Type NM LISTED
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8
AMERBRITE UNDERWATER WHITE LED POOL LAMP
AMERBRITE UNDERWATER WHITE LED POOL LAMP FOR USE ONLY WITH PENTAIR AMERLITE LUMINAIRE INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V
Installation Smart-UPS VT MGE Galaxy 3500 Maintenance Bypass Panel 10-40 kva 400 V Contents Safety.................................................. 1 Save these instructions...................................
Addendum to the Operating Instructions
Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions MOVIMOT with AS-Interface and AC Motor DT/DV Unit Replacement MOVIMOT MM..C -> MM..D with MLK3A
12-Volt Negative Ground Installation Instructions
12-Volt Negative Ground Installation Instructions For Part Number: 1141, 1164, 1165, 1181 CAUTION!!! Before installing, please read the following important information... 1. The Ignitor is designed for
FAQ s on Siemens Magmeters
FAQ s on Siemens Magmeters 1. The cables for the coils and electrodes for the magmeters look the same. Does it matter which cable is used for coils and which one is used for the electrodes? Both cables
PART 1 - INTRODUCTION...
Table of Contents PART 1 - INTRODUCTION... 3 1.1 General... 3 1.2 Sensor Features... 3 1.3 Sensor Specifications (CDE-45P)... 4 Figure 1-1 CDE-45P Sensor Dimensions (standard, convertible style)... 4 PART
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors
Char-Lynn Spool Valve Hydraulic Motors Repair Information W Series Geroler Motors with Parking Brake 004 Nut Key Ring, Retaining Bearing Ring, Retaining Ring, Retaining Washer (Thick), Pressure Washer,
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
Installation Instructions 4508 4508S
SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect
Owner's Copy. 104873 December 14, 2011 ELECTRICAL INSTRUCTIONS FOR ADVANTEX EA OR EX MODELS
104873 December 14, 2011 Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045 (830)629-2900 / 1-800-729-3839 / Fax (830)620-6711 E-MAIL: [email protected] INTERNET: www.detex.com ELECTRICAL
EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications
EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin
Servo Info and Centering
Info and Centering A servo is a mechanical motorized device that can be instructed to move the output shaft attached to a servo wheel or arm to a specified position. Inside the servo box is a DC motor
Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series
Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series Operating Instructions WARNING CONCERNING THE REMOVAL OF COVER: CAUTION: TO PREVENT THE RISK OF ELECTRIC
Armature Actuated Brakes
Armature Actuated s P/N 8-078-890-05 effective 05/02/14 Installation and Service Instructions Series AAB Armature Actuated s Sizes 72 through 170 Model Numbers 33[ ]-1, 33[ ]-2, 33[ ]-3, 33[ ]-4, 33[ ]-5
This page is subject to proprietary rights statement on last page
FLT93 Series Flow and Level Switches Instructions for Conversion/Replacement of Through-Hole Electronics (P/N 5294 type) With New Surface Mount Electronics (P/N 5208 type) This guide is provided to owners
Flowserve - Edward Valves Quick Closing Isolation Valves -The Equiwedge Alternative
Flowserve - Edward Valves Quick Closing Isolation Valves -The Equiwedge Alternative Problem Fast isolation of a large bore main steam or feedwater line during a pipe rupture that seals flow in both directions.
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Toroidal Conductivity Sensor
Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:
DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
Series 30000 Hose Reels
Operating Instructions and Parts List for Series 30000 Hose Reels - MANUAL DRIVEN - - POWER DRIVEN - SAFETY PRECAUTIONS Personal injury and/or equipment damage may result if proper safety precautions are
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
Trunnion-Design Ball Valves
Trunnion-Design Ball Valves 12" 20" (DN 300 500) Series 7150 12" (DN 300) Series 730S 12" 20" (DN 300 500) Series 7300 14" 24" (DN 350 600) Series 9150 14" 24" (DN 350 600) Series 9300 Installation, Maintenance
3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE
4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia