EXTRA. NHBC s technical newsletter April 2002 Issue 23. This edition includes:

Size: px
Start display at page:

Download "EXTRA. NHBC s technical newsletter April 2002 Issue 23. This edition includes:"

Transcription

1 NHBC s technical newsletter April 2002 Issue 23 This edition includes: Major changes to NHBC glazing Standards Glazing requirements amended to improve the durability of insulating glass units. Changes to NHBC Standards to align with Approved Document L and Robust Details Detailed changes made to a number of Chapters. Changes to NHBC Standards Chapter 6.8 to align with Approved Document J Chapter 6.8 now revised to ensure chimney and flues meet the new AD. What is the expected life of my new home? What durability is NHBC looking for? Use of non-entry inspection chambers Are deep inspection chambers accepted by NHBC? EXTRA STANDARDS EXTRA 1

2 CONTENTS 2 Major changes to NHBC glazing Standards 3 Approved Document L and Robust Details 3 Approved Document L - Commissioning central heating systems 3 SAP Standards Chapter 6.8 Fireplaces, chimneys and flues 4 Flooring - fixing and perimeter support 5 Timber frame certification in Scotland 5 What is the expected life of my new home? 6 Non-entry inspection chambers 6 Preparing for Floods 7 Concrete in aggressive ground 7 Pavers - which pattern is appropriate? 8 Questions & Answers Major changes to NHBC glazing Standards For more than two years NHBC has been providing cover for multiple glazing. It is now appropriate that the Standards for glazing, contained in Chapter 6.7, Doors, windows and glazing, should be reviewed and amended to reflect changes to recommended practice. This article explains what the changes are, but house builders are asked to look at the revised pages of the Chapter for further details. These are enclosed separately. The main changes are: Insulated glass units (IGUs) will need to meet the requirements of BS EN 1279, Glass in building-insulating glass units. This is the new European standard which will replace BS 5713, Specification for hermetically sealed flat double glazed units. Units to BS 5713 will continue to be acceptable until BS EN 1279 is published. Publication is expected later in IGUs should now be specified as having dual seals - single seal units will no longer be accepted. This change is intended to ensure significantly improved durability. Desiccant should be provided to every section of spacer bar. All IGUs are now required to have third party certification (e.g. Kitemarking). This applies to IGUs installed in all types of frame, including timber windows and windows fabricated under a BBA certificate. Site glazing is still permitted, but the bottom bead must be drained and ventilated. Solid bedding is accepted only for factory-glazed windows and doors where the IGU is up to 1m 2 in area. For factory-glazed windows and doors having IGUs over 1m 2 in area, the bottom bead must be drained and ventilated. It is important that NHBC inspection staff and others can verify whether the units and glazing meets with the new standard. Some aspects have to be marked on the unit or the window itself. This is often a requirement of the unit or window standard, and by not marking the manufacturer is not conforming. IGUs Marking Units to BS EN 1279 / BS ) Manufacturer s name or trademark. 2) The number of the British Standard i.e. BS ) The Kitemark. Where On the glass or spacer bar of every unit in such a way that the marking can be seen after the units are installed. Windows Marking BS 7412 for PVC-U windows 1) Manufacturer s name or trademark. 2) The number of the British Standard i.e. BS ) The Kitemark. Where In an unobtrusive position such as between the casement and frame. Marking BBA certificated windows Each window should have a label bearing the manufacturer s name or trademark and the BBA identification mark incorporating the certificate number. The new requirements will become effective from 1 October Ensure that you are fully aware of the detailed changes, and that the correct windows and IGUs are being purchased and used on site. 2 STANDARDS EXTRA

3 Approved Document L and Robust Details In Standards Extra 22 we advised of the publication of the 2002 edition of Approved Document L (AD L), Conservation of fuel and power (England and Wales), and the separate publication, Robust Details to which it refers. A major review of the NHBC Standards has been necessary to ensure that they align with both AD L and Robust Details. Although a total of nine chapters have needed some amendment, the main changes are to Chapters 6.1, External masonry walls, and 6.2, External timber framed walls. The main changes to NHBC Standards are: Door and window openings now require better sealing to prevent air leakage. Additional precautions to prevent cold bridging particularly at lintels and reveals. Sealing of sole plates of timber frame construction to prevent air leakage. Amendment to the minimum dimension for ventilation paths in cold pitched roofs. References to Robust Details, particularly in Chapter 5.2, which deals with suspended floors of both concrete and timber. AD L and the Robust Details only apply under the Building Regulations in England and Wales. In Scotland, Part J has been amended to refer to the latest edition of the BRE publication, Thermal Insulation: avoiding risks. Currently in Northern Ireland, the regulations have not changed. However, it is likely they will be amended in a similar way to those in England and Wales in due course. Builders in England and Wales should note that the 2002 edition of AD L comes into effect on 1 April, and will be applicable to some homes started before October Stop press On DTLR's behalf, the Building Research Establishment has set up a "Frequently Asked Questions" internet site as a means of delivering answers to questions that are being raised in connection with Approved Documents L1 and L2. The address is: Builders should familiarise themselves with the changes to NHBC Standards which are effective for all homes from 1 October Approved Document L - commissioning central heating systems, the Benchmark scheme. One of the changes to the 2002 edition of Approved Document L (AD L), is a new requirement for heating and hot water systems to be inspected on completion, and commissioned to ensure that they are operating efficiently. At the same time a 'suitable commissioning certificate' is to be issued to confirm this. AD L specifically refers to the certificate published by Benchmark, as being suitable. A copy of the Benchmark certificate is supplied with over 90% of all gas boilers currently sold in the UK. Benchmark certificates should be completed by suitably qualified certifiers, such as CORGI registered installers for gas, OFTEC registered technicians for oil, and HETAS registered installers for solid fuel systems. Further information on the Benchmark Scheme is available from the Central Heating Information Council at For homes built to the new AD L ensure that a suitable commissioning certificate, such as that produced by Benchmark, is completed for each installation. SAP 2001 The latest version of the Government s Standard Assessment Procedure (SAP 2001) is now available. It replaces the 1998 edition. The main changes are: the Carbon Index is introduced (this is a new means of showing compliance with the 2002 edition of Approved Document L) the upper limit of the SAP rating is raised from 100 to 120 the SAP indexing function is revised to make the rating less dependent on floor area some additional heating systems are included data tables are updated (including those for boiler efficiency and heating controls) U-values should be based on European Standards. Until 30 June 2002, builders may use either SAP 1998 or SAP 2001 to calculate energy ratings notified to the building control body. Energy ratings notified on or after 1 July 2002 must use SAP Where the energy rating was calculated using SAP 1998 and notified to the building control body before 1 July 2002, the SAP rating on the notice displayed in the home must be to SAP Builders may however, display the SAP 2001 rating (on the expanded scale) in addition. Further information and a downloadable version of SAP 2001 is available at A copy of DTLR circular letter to building control bodies is also available at STANDARDS EXTRA 3

4 Standards Chapter 6.8, Fireplaces, chimneys and flues The Standards update pack includes pages to update Chapter 6.8, Fireplaces, chimneys and flues, to reflect changes in the 2002 edition of Approved Document J (AD J), Combustion appliances and fuel storage systems. The main changes to Chapter 6.8 are: Notice plates, containing safety information, are now required to ensure the correct application and use of the hearth and flue. Hearths have to be marked so that home owners do not apply combustible floor finishes, such as carpets, too close to the appliance. One way of achieving this is to provide a change of level at the hearth. Outlet positions from flues for solid fuel, gas and oil have changed. In particular, positions for flue outlets adjacent to a boundary have been changed. Ventilation requirements have been changed for solid fuel, gas and oil appliances. Concrete flue liners should now meet with a draft European standard. Although the changes to AD J apply in England and Wales only, it is likely that similar changes will be made to Regulations in Scotland and Northern Ireland in due course. NHBC takes the view that notice plates are a sensible way of giving home owners essential information on the safe use of the flue and hearth for the life of the home, and so NHBC is also applying this requirement in Scotland and Northern Ireland. An example of a notice plate is shown above. Plates should be installed in an obvious position that need not be intrusive, such as: next to the electricity consumer unit, or next to the chimney or hearth, or next to the water supply stop valve. The plate should be robust, legibly and permanently marked and securely fixed. Builders in England and Wales should note that the 2002 edition of AD J comes into effect on 1 April, and will be applicable to some homes started before October Builders should familiarise themselves with the changes to Chapter 6.8, which are effective for all homes from 1 October Flooring fixing and perimeter support Fixing of flooring Squeaking floors are a regular source of irritation to home owners and amongst the most common complaints. It can be exceptionally difficult to put problems right in occupied homes, particularly where carpets have been laid and rooms are full of furniture. To reduce the incidence of squeaking floors, NHBC has decided to adopt the recommendations of BS 7916, Code of practice for the selection and application of particleboard, oriented strand board (OSB), cement bonded particleboard and wood fibreboards for specific purposes. This calls for boards to be glued together and to be glued to the floor joists. The appropriate adhesive for both operations is polyvinyl acetate (PVAC). The chipboard or OSB manufacturer should be able to advise on specific recommended products. The adhesive is required in addition to mechanical fixings, which should be provided as specified in NHBC Standards, Chapter 6.4. Perimeter support to chipboard flooring We are often asked whether perimeter support to chipboard flooring needs to be provided in all situations, and builders have queried whether perimeter support can be left out if thicker boards are used on closely spaced joists. NHBC Standards are taken from BS 7916 and the matter has been referred back to the BSI committee responsible. That committee has concluded that chipboard flooring should always be supported at the perimeter, regardless of the thickness of the boards and the spacing of the floor joists. Perimeter noggings should be provided for all chipboard floors. If you are using chipboard or OSB floor decking, joints between boards should be glued and boards should be glued to the floor joists. The new requirements will come into effect from 1 October STANDARDS EXTRA

5 Timber frame certification in Scotland NHBC has made an administrative change to form HB210, Timber Frame Construction, which is used in Scotland. Until now completed forms have been delivered to NHBC s Scottish office. In future the form should be given by the certifier to the house builder who should make it available to NHBC inspection staff on site. Timber frame certifiers can obtain the new forms from either the NHBC Edinburgh office, or NHBC Technical in Amersham. Certifiers may use up supplies of old forms, but should follow the new procedure and send the completed form to the builder. When building timber frame dwellings in Scotland, ensure that a completed HB210 form is available for NHBC inspection staff on site. What is the expected life of my new home? This is a question we are often asked in NHBC Technical. Until quite recently, most homes have been built of conventional construction, usually with an outer leaf of brick and inner leaf of blockwork or timber frame. The notional design life is sixty years but with proper maintenance there is no reason why homes should not last much longer and many do. There are, of course, certain parts of the external envelope, which have a lesser design life and which may need planned maintenance and possible replacement. Examples are flat roof coverings and doors and windows. Home owners are generally aware of these limitations and accept them as part of the ongoing commitments they have to budget for. As a consequence, NHBC has not in the past specified a period for the design life or durability. More recently we have received proposals from manufacturers and builders to use novel or innovative building systems, products and materials, including some with a design life considerably less than that of conventional construction. Although Buildmark provides cover for ten years, NHBC Standards start from the presumption that home owners (and their mortgage lenders) should get homes which are reasonably durable, and certainly well beyond the tenth year. To reflect this, a change has been made to Technical Requirements R3 (Materials Requirement) and R5 (Structural Design Requirement) to ensure that homes are designed with a durability of at least 60 years for the structure. This is not likely to have any implications for traditionally constructed homes of masonry or timber frame. Note the changes to Technical Requirements R3 and R5. Builders intending to construct homes where durability may differ from the norm should discuss their proposals with NHBC Technical at the earliest opportunity. These changes apply immediately. STANDARDS EXTRA 5

6 Non-entry inspection chambers The recent introduction of a non-entry inspection chamber by a major manufacturer has caused much discussion. Other manufacturers are also known to be developing similar products. Picture supplied by Wavin Plastics Ltd. What are non-entry inspection chambers? As the name suggests, these are chambers for which all access for maintenance of the drain (i.e. rodding) is achieved from the surface. For health and safety reasons, they have a restriction just beneath the cover to deter human entry. How deep can the inspection chamber be? A new British Standard BS 7158, Specification for plastics inspection chambers for drains, is for plastic inspection chambers up to 6m deep from cover to invert. However, the one currently on the market is limited to a maximum depth of 3m, which in practice is sufficient for most housing developments. As the invert depth increases, the pressures on the chamber increase, so to avoid the risk of collapse the maximum depth recommended by the manufacturer should not be exceeded. Do they meet with Building Regulations? Non-entry inspection chambers are referred to in the new 2002 edition of Approved Document H (AD H) for England and Wales, and BS EN 752, Drain and sewer systems outside buildings. Table 11 of the AD specifies suitable dimensions for the chambers and covers, and Table 13, the maximum spacings. The maximum distance between chambers should not exceed 45m, although in most housing developments chambers are likely to be much closer. Part M of the Building Standards (Scotland) and Part N of the Northern Ireland Building Regulations do not currently recognise the use of non-entry inspection chambers. Can non-entry inspection chambers be used by NHBC registered builders? If non-entry chambers meet with BS 7158 for a specified invert depth, then they can be used. The invert depth should not exceed that specified by the manufacturer (3m for the product currently available). If you intend to use non-entry inspection chambers, ensure they meet the above criteria, and that the maximum distance between them does not exceed 45 metres. Preparing for Floods Interim Guidance for Improving the Flood Resistance of Domestic and Small Business Properties. As Standards Extra 23 goes to print, this new DTLR document is being published as Interim Guidance. Recent flooding events across the UK have had a devastating impact on many lives and businesses. Unfortunately the risk of flooding cannot be eliminated. The new guide, for the first time in a single publication, collates best practice guidance on measures for improving flood resistance of new and existing properties that are at risk. The guide is for existing home owners and small businesses with properties at risk of flooding, as well as for developers, builders, local planning authorities, building control bodies, and others involved with new construction or with renovation in areas of flood risk. It deals with assessing the risk, with temporary and permanent measures to prevent or reduce floodwaters entering a building, and with improving the flood resistance of the building. Real life case studies are also provided. The guide also gives an overview of PPG 25:Development and Flood Risk, and of the types of construction most appropriate for developments at risk of flooding. NHBC is one of several organisations that assisted in the funding of this project, led by WS Atkins Consultants Ltd. Information was drawn from a range of official sources as well as home owners, small businesses and builders. Free copies will be available from the Environment Agency's Floodline on , and electronically via the DTLR website. 6 STANDARDS EXTRA

7 Concrete in aggressive ground The industry specification for concrete at risk from sulfate attack has been defined for the past decade in BRE Digest 363, ''Sulfate and acid resistance to concrete in the ground''. Information obtained from a study of sulfate attack on concrete road bridges has led to a better understanding of the specification needed to resist chemical attack. As a result, BRE Digest 363 was withdrawn and replaced, in August 2001, with the four part BRE Special Digest 1, ''Concrete in aggressive ground''. Sites now need to be classified in terms of their Aggressive Chemical Environment for Concrete (ACEC). This is derived from the site investigation and is based upon: the sulfate content of the soil and groundwater the presence of mobile or static groundwater the acidity of the soil and groundwater and whether the site is natural or brownfield. Once the ACEC has been ascertained, the Design Chemical Class (DC Class) of the concrete can be determined. This provides the performance requirement for the concrete for the specific site conditions. The DC Class, which could be compared with the Sulfate Classes in the old BRE Digest 363 for certain acidic and ground water conditions, is determined from the ACEC, but consideration also has to be given to: the Structural Performance Level of the element (e.g. low where the element is for house foundations and high where the element is for structures retaining hazardous materials) the section thickness of the element the Additional Protective Measures provided to the element (e.g. surface protection or sacrificial layer). With the DC Class established, the concrete grade can be selected in accordance with the soon to be revised BS 5328, ''Concrete''. In general terms a concrete that was suitable to satisfy the requirements of Class 1 or Class 2 sulfate conditions under BRE Digest 363, is also likely to satisfy Design Chemical Classes DC1 and DC2 respectively. The changes incorporated in Special Digest 1 will be reflected in a revised BS 5328 which is due to be published later this year. Ultimately, in December 2003, it is likely that BS 5328 will be replaced with a new package of standards. This package will include the current BS EN 206, ''Concrete'' and BS 8500, ''Concrete'' which is in preparation. NHBC s Standards will be amended to reflect changes to the British Standards as they become available. Until then, concrete should be specified in accordance with the new guidance in BRE Special Digest 1. Concrete should be specified in accordance with BRE Special Digest 1 and the new BS Ready mixed concrete suppliers will be able to provide suitable concrete mixes for appropriate DC Classes. Pavers - which pattern is appropriate? Clay and concrete paver blocks are becoming a popular choice for builders when looking to enhance the visual appeal of a property. The paver has also become a sustainable alternative to the use of tarmac, with its surface water drainage capabilities. When installing this type of finish builders should be aware that the laying pattern needs to be appropriate for the likely traffic. There are a number of patterns that can be used but, a number of these should not be used for areas subject to vehicular traffic. British Standard 7533 "Code of practice for laying precast concrete paving blocks and clay pavers for flexible paving" states: "Where rectangular units are being used in areas subject to vehicular traffic, herringbone pattern should be used to minimise creep and to ensure better distribution of imposed wheel loads. Basket weave pattern should only be used in pedestrian areas. Running bond pattern is usually confined to pedestrian areas but has been successfully used in areas subject to occasional light vehicular traffic" The Brick Development Association ( Design Note 9 gives similar advice and paver manufacturers who hold BBA certification for their products state that the bond for rectangular pavers should be herringbone. 45 degree Herringbone 90 degree Herringbone Running Bond Basket Weave To ensure creep of the pavers is kept to a minimum, they should be laid in accordance with BS 7533, which recommends that herringbone pattern should be used in areas subject to vehicular traffic. Running bond should only be used for pedestrian areas or private driveways. STANDARDS EXTRA 7

8 Questions & Answers Below are the answers to a selection of questions we have recently been asked in NHBC Technical. Noggings for lateral restraint straps Question Can noggings to lateral restraint straps be kept down from the top of the joists to accommodate services? Answer NHBC Standards clause 6.4-S10 requires full depth noggings where lateral restraint straps are fixed to the underside of joists and noggings of at least half depth where the straps are fixed on top of the joists. In both cases the noggings are in contact with the straps. However, these arrangements can be difficult to accommodate services. full depth packing 50mm max reduced depth nogging where there are services service restraint strap at either the top or bottom of the joists full depth noggings where there are no services Noggings act as struts to resist movement of the wall and should not be weakened by excessive notching or drilling. Where services are located in the top of the floor zone and are obstructed by a nogging, that nogging may be kept down from the top of the joists by 50mm. Adjacent noggings/packing should be the full depth of the joist as shown in the diagram above. Gaps around PVC-U windows Question What is the maximum gap that should be permitted for sealant around a PVC-U window? Answer A gap should be provided to allow for thermal expansion of the window. A gap of 5-10mm (evenly distributed) should be provided around PVC-U windows. In the case of large windows or patio doors a maximum gap of 15mm may be permissible. Dpc trays to rendered walls Question On fully rendered masonry walls, do cavity trays need to be provided over openings? If so do they require weepholes and stop ends? Answer Wind driven rain may penetrate rendered masonry through minor cracks, around openings, and at architectural details. Cavity trays with stop ends are required over all openings. Weepholes do not need to be provided where masonry walls are fully rendered. End support to chipboard flooring Question Where end joints in chipboard flooring occur between joists, how should the joints be supported? Answer End joints should usually be located over a joist; failure to provide adequate support will significantly weaken the floor. For all thicknesses of flooring, joist centres and types of chipboard, an H frame should be provided under all end joints occurring between joists. The frame should be securely fixed to adjacent joists. 8 NHBC Technical Buildmark House, Chiltern Avenue, Amersham, Bucks HP6 5AP Tel: Fax: technical@nhbc.co.uk HB /03

Energy Company Obligation (ECO): Technical Monitoring Questions

Energy Company Obligation (ECO): Technical Monitoring Questions Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified

More information

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37 Contents Pages Full fill cavity walls 2-13 Partial fill cavity walls 14-25 Solid externally insulated walls 26-37 Appendix (BRE confirmation of Ψ and y-values) 38-40 Page 1 of 40 APA Construction Details

More information

Module 3.7. Thermal bridging

Module 3.7. Thermal bridging Module 3.7 Thermal bridging Learning Outcomes On successful completion of this module learners will be able to - Describe construction details which influence thermal bridging. 2 Introduction to thermal

More information

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01. Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice

More information

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. This leaflet provides guidance on how to attain compliance with The Building (Amendment) Regulations (Northern Ireland) 2006, Part

More information

Approved Document Q: Security

Approved Document Q: Security Approved Document Q: Security Requirement Q1 Unauthorised access Consultation draft September 2014 1 The approved documents What is an approved document? The Secretary of State has approved a series of

More information

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing Good Craftsmanship Guide Carpentry and Joinery- Carcassing Introduction This Good Craftsmanship Guide highlights key problems with the major elements of Carpentry and Joinery - Carcassing, and gives guidance

More information

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Cl Sfb (27-9) Rn7 M2 December 2004 Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Fesco, Fesco S, Retrofit, Retrofit S, Fesco Fillet, PF,

More information

Rockwool Flexi Insulation Application Guide

Rockwool Flexi Insulation Application Guide Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed

More information

WARMFILL CAVITY WALL INSULATION WARMFILL CAVITY WALL INSULATION FOR MASONRY CAVITY WALLS

WARMFILL CAVITY WALL INSULATION WARMFILL CAVITY WALL INSULATION FOR MASONRY CAVITY WALLS Warmfill Limited Unit 5, Port of Larne Business Park Redlands Road Larne BT40 1AX Tel: 028 9042 8260 Fax: 028 9042 7641 e-mail: sales@warmfill.com website: www.warmfill.com APPROVAL INSPECTION TESTING

More information

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery Part 3 Ancillary technologies Chapter CONTENTS SCOPE Clause Page DESIGN Design standards D1 1 Statutory requirements D2 1 System design D3 1 Building integration D4 2 Noise D5 2 Access and controls D6

More information

Financial Services Authority

Financial Services Authority Financial Services Authity Notice of undertaking Introduction As a qualifying body, we, the Financial Services Authity (the FSA), can challenge firms using terms which we view as unfair under the Unfair

More information

Guide to the safe installation of downlighters in dwellings

Guide to the safe installation of downlighters in dwellings Guide to the safe installation of downlighters in dwellings Technical guidance for designers and installers 01 Guide to the safe installation of downlighters in dwellings Technical guidance for designers

More information

KINGSPAN INSULATION KINGSPAN KOOLTHERM K12 FRAMING BOARD INSULATION

KINGSPAN INSULATION KINGSPAN KOOLTHERM K12 FRAMING BOARD INSULATION Kingspan Insulation Limited Pembridge Leominster Herefordshire HR6 9LA Tel: 01544 388601 Fax: 01544 388888 e-mail: general.enquiries@kil.kingspan.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

Agrément Certificate 06/4300 Product Sheet 1

Agrément Certificate 06/4300 Product Sheet 1 Domestic and General Insulation Ltd Energy House Magnis Works Roman Road Hereford HR4 9QR Tel: 0844 543 0043 Fax: 01432 268680 e-mail: headoffice@dgi.org.uk website: www.dgi.org.uk APPROVAL INSPECTION

More information

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING 6.CW.1A TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS wood or gas standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING The Fireplace Ltd is able to design and fabricate custom brick open masonry

More information

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,

More information

Timber Frame Walls Rethinking Construction

Timber Frame Walls Rethinking Construction Insulation Fifth Issue November 2007 Timber Frame Walls Rethinking Construction INSULATION BEST PRACTICE FOR THE 21ST CENTURY Summary 9 mm OSB sheathing 3 mm skim coated 15 mm plasterboard Rock or glass

More information

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory

More information

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

CHESTERFLEX ROOF WATERPROOFING MEMBRANES CI/SfB (47) Ln2 Chesterfelt Ltd CHESTERFLEX ROOF WATERPROOFING MEMBRANES Certificate No 94/3062 DETAIL SHEET 2 Product THIS DETAIL SHEET RELATES TO CHESTERFLEX ROOF WATERPROOFING MEMBRANES, POLYESTER REINFORCED

More information

2014 British Columbia Building Code Changes

2014 British Columbia Building Code Changes District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most

More information

Loss Prevention Standard

Loss Prevention Standard Loss Prevention Standard LPS 1581: Issue 2.1 Requirements and tests for LPCB approval of nonload This Loss Prevention Standard is the property of BRE Global Ltd. and is made publicly available for information

More information

Installation Instructions

Installation Instructions Installation Instructions Pedestal Models FS 500 LE FS 800 LE Insert Models IS 500 LE IS 800 LE Pecan Engineering Pty Ltd 13 Acorn Road Dry Creek South Australia 5094 Email info@pecan-eng.com.au Phone:

More information

Code of Practice for fire resisting metal doorsets

Code of Practice for fire resisting metal doorsets COP 1005 Code of Practice for fire resisting metal doorsets Scope The aim of this document is to provide guidance on the best practice for, and a better understanding of, hinged or pivoted fire resisting

More information

CI/SfB (31.9) BETTER BY DESIGN PRODUCT GUIDE COMPLETE GUIDE TO THE IG PRODUCT RANGE. www.iglintels.com

CI/SfB (31.9) BETTER BY DESIGN PRODUCT GUIDE COMPLETE GUIDE TO THE IG PRODUCT RANGE. www.iglintels.com CI/SfB (31.9) Hh2 BETTER BY DESIGN PRODUCT GUIDE COMPLETE GUIDE TO THE IG PRODUCT RANGE www.iglintels.com BETTER BY DESIGN IG produce the UK s largest range of steel lintels backed by industry leading

More information

Building Warrant Issues

Building Warrant Issues Building Warrant Issues Frequently Asked Questions Introduction This section is intended to help anyone who is unfamiliar with the building standards system in Scotland. The information contained in it

More information

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010 Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance

More information

BER Assessors Dwellings Technical Bulletin

BER Assessors Dwellings Technical Bulletin BER Assessors Dwellings Technical Bulletin Issue No. 2/12 April 2012 Contents: 1. SUPPLEMENTARY ELECTRIC WATER HEATING IN SUMMER... 2 2. PITCHED ROOF U-VALUE CALCULATIONS... 8 2.1. PITCHED ROOF, INSULATED

More information

TECHNICAL MANUAL. New Homes

TECHNICAL MANUAL. New Homes TECHNICAL MANUAL New Homes V2 Contents Part 1...5 Introduction and statutory requirements...5 General introduction, layout and use of the manual....5 Functional Requirements...6 Compliance with Building

More information

Proposed Minimum Subterranean Termite Treatment Standards

Proposed Minimum Subterranean Termite Treatment Standards Proposed Minimum Subterranean Termite Treatment Standards Introduction This document is intended to serve as a model for states considering the adoption of standards for soil application of termiticides.

More information

House building is changing fast NHBC unveils new Standards Chapters on curtain walling and cladding, and light steel framed walls and floors

House building is changing fast NHBC unveils new Standards Chapters on curtain walling and cladding, and light steel framed walls and floors W42_Stand_Extra_32 15/3/05 9:17 am Page 2 NHBC s technical newsletter April 2005 Issue 32 This edition includes: 2 House building is changing fast NHBC unveils new Standards Chapters on curtain walling

More information

Energy Efficient Windows

Energy Efficient Windows Energy Efficient Windows All properties lose heat through their windows. But energy-efficient glazing keeps your home warmer and quieter as well as reducing your energy bills. That might mean double or

More information

The WANZ Guide to Window Installation

The WANZ Guide to Window Installation The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 Ver. 1.1 Page 2 of 74 Contents Overview Page 5 Objective Page 5 Scope Page 5 Opening Preparation Page 7 Step P1 Preliminary Check

More information

Rev 1-12.2013. Code of Practice. SIP Technology. www.uksips.org

Rev 1-12.2013. Code of Practice. SIP Technology. www.uksips.org Rev 1-12.2013 Code of Practice SIP Technology www.uksips.org What are Structural Insulated Panels (SIPS)? SIPS are prefabricated, high performance, lightweight, building panels that can be used in floors,

More information

Building Regulations for the Conservation of Fuel and Power

Building Regulations for the Conservation of Fuel and Power Insulation CI/SfB Rn7 M2 First Issue April 2014 Building Regulations for the Conservation of Fuel and Power ENGLAND EXISTING DWELLINGS 2013 EDITION Low Energy Low Carbon Buildings Contents Page Introduction

More information

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 E1 E2 E3 E4 E Protection against sound from other parts of the building and adjoining buildings Protection against

More information

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Services Enclosures and Protected Shafts - Maintaining Compartmentation Introduction When a fire resisting element is used to provide fire compartmentation, every opening that allows services to pass through the element must be adequately protected by sealing, or fire stopping

More information

Building Control Guidance Note

Building Control Guidance Note Elements Renovation / Replacement. Issued 25/01/13 Rev a Page 1 of 9 (Applies to both Domestic and Non-Domestic Premises) Works relating to thermal elements can arise in building an extension, a material

More information

Building Control Guidance Note

Building Control Guidance Note Issued 01/01/13 Rev Page 1 of 5 If you intend to convert an existing loft space into additional rooms you will need to apply for Building Regulation Approval. You may also need Planning Permission if you

More information

Guide to working on Public Sewers

Guide to working on Public Sewers Guide to working on Public Sewers affected by Building Works Introduction Severn Trent Water Ltd requires the work to be done in order to protect the public sewer and minimise the risk of us having to

More information

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS NOISE TECHNICAL FACT SHEET FACT SHEET 5 SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS The sound insulation of exterior walls and roof-ceiling systems refers to their ability to reduce external

More information

The Scottish Building Standards TECHNICAL HANDBOOK CONSERVATORIES

The Scottish Building Standards TECHNICAL HANDBOOK CONSERVATORIES The Scottish Building Standards TECHNICAL HANDBOOK CONSERVATORIES The Scottish Building Standards TECHNICAL HANDBOOK CONSERVATORIES Crown copyright 2006 Cover designed and produced by Astron Text pages

More information

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with Section Separating Floors Timber frame floor with I-Beams Product: Earthwool Acoustic Roll and Floorfoam Easy Edge Strip Timber frame floor with solid timber joists Product: Earthwool Acoustic Roll and

More information

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS. Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS. Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance

More information

DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES

DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES WBCA 403 DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES A guide to assist those intending to install or who are involved in installing conservatories. Includes information about: conservatory and component

More information

Timber Frame Construction

Timber Frame Construction Timber Frame Construction Introduction Design and Detailing What is timber? Failure modes History of timber frame construction Forms of timber frame construction Live and dead loads Wind loads Roof construction

More information

Glass and Building Regulations Impact Safety

Glass and Building Regulations Impact Safety Glass and Building Regulations Impact Safety England and Wales Approved Document N Scotland Part P Northern Ireland Part V Foreword For new buildings, and for buildings subject to major refurbishment,

More information

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS The following guidelines are intended to assist with the permit acquisition process with regard to Plumbing Alterations. Not all information, or additional

More information

Building over or close to a public sewer

Building over or close to a public sewer Building over or close to a public sewer thameswater.co.uk/developerservices thameswater.co.uk/developerservices 1 Questions and answers Did you know Thames Water is legally responsible for more than 100,000

More information

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003) NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining Section Timber Frame Walls Single layer between studs Product: Earthwool FrameTherm Rolls and Slabs Tf01 Single layer between studs with service void Product: Earthwool FrameTherm Rolls and Slabs Tf02

More information

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION Bill Robinson BSc. C. Eng. M. I. Struct. E. Timber Design Services 1 IS440 Timber frame

More information

Protecting your property from Flooding. SCOTTISH ENVIRONMENT PROTECTION AGENCY www.sepa.org.uk

Protecting your property from Flooding. SCOTTISH ENVIRONMENT PROTECTION AGENCY www.sepa.org.uk SCOTTISH ENVIRONMENT PROTECTION AGENCY www.sepa.org.uk Protecting your property from Flooding Contents Introduction... 3 The sources of flooding... 4 Assessing the risk of flooding... 5 How water can enter

More information

Repairing your business or home after a flood how to limit damage and disruption in the future.

Repairing your business or home after a flood how to limit damage and disruption in the future. Repairing your business or home after a flood how to limit damage and disruption in the future. This factsheet provides customers who have been flooded or are likely to be affected by flooding with a guide

More information

Standards Committee T echnical Technical Conference

Standards Committee T echnical Technical Conference Standards Committee Technical Conference Agenda Overview of claims costs Years 0 2 claims and resolutions Years 3 10 claims What are we commonly seeing now? An example of what we might see in future? Summary

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 14, Clifton Road, Anfield, LIVERPOOL, L6 4BQ Dwelling type: Groundfloor flat Date of assessment: 27 January 2009 Date of certificate: 27 January 2009 Reference number: 21389078626951619080

More information

Solo for Self Build. A guide to the cover

Solo for Self Build. A guide to the cover Solo for Self Build A guide to the cover Choosing the plot, arranging planning permission and finance, designing and building your dream home and finally moving in. Building your own home is, without doubt,

More information

SIP (STRUCTURAL INSULATED PANEL)

SIP (STRUCTURAL INSULATED PANEL) SIP (STRUCTURAL INSULATED PANEL) KINGSPAN TEK ACORN SIP ABSTRACT BUILDING SERVICES Ltd Kingspan TEK is the manufacturer and supplier of the panels and components. Acorn SIP are the Architects who individually

More information

Low Carbon Domestic Refurbishment

Low Carbon Domestic Refurbishment www.breeam.com Briefing Paper Low Carbon Domestic Refurbishment Kiruthiga Balson, Gavin Summerson and Steven Stenlund 2 BRE Global Ltd 2014 Permission is granted for this report to be distributed only

More information

Rockwool Cladding Roll

Rockwool Cladding Roll Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F

More information

STEP-BY-STEP. construction guide. Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet.

STEP-BY-STEP. construction guide. Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet. STEP-BY-STEP construction guide Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet. Welcome to our CONSERVATORY AND SUNROOM CONSTRUCTION GUIDE What is the specification

More information

plumbing products guide

plumbing products guide plumbing products guide radiator pipe guide & seals A significant development in the drive to reduce air leakage and heat loss. Installations such as that shown are all too common. The detail is poorly

More information

Dunbrik A1 Concrete Flue Liners for domestic chimneys Installation Guide

Dunbrik A1 Concrete Flue Liners for domestic chimneys Installation Guide Dunbrik A1 Concrete Flue Liners for domestic chimneys Installation Guide Topguard bird cowl Cannon head chimney pot Weather flaunching on capping brickwork with drip overhang Lead flashing & saddle tray

More information

DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP

DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP CONTENTS WHAT IS RISING DAMP STEP 1 SURVEY STEP 2 METER READINGS STEP 3 CONCLUSION STEP 4 PREPARATION FOR TREATMENT STEP 5 TYPE OF TREATMENT STEP 6

More information

LAYING BLOCK AND BRICK

LAYING BLOCK AND BRICK LAYING BLOCK AND BRICK Products highlighted in this section: SAKRETE Type N Mortar Mix SAKRETE Type S Mortar Mix Brick And Block Laying Basics The first step in building a brick or block wall is to construct

More information

Chapter 5.4. Waterproofing of basements and other below ground structures

Chapter 5.4. Waterproofing of basements and other below ground structures Chapter Waterproofing of basements and other below ground structures Waterproofing of basements and other below ground structures CONTENTS SCOPE DESIGN Clause Page D1 Design standards D1 2 D2 Statutory

More information

Condensation. Some Causes, Some Advice

Condensation. Some Causes, Some Advice Condensation Some Causes, Some Advice The Problem Condensation on windows and in conservatories, and the damage it does to paintwork, curtains, wall coverings and window fittings, are problems frequently

More information

Guidance Note on the Need for Planning Permission for the Development of Existing Houses and Flats (effective from 6 February 2012)

Guidance Note on the Need for Planning Permission for the Development of Existing Houses and Flats (effective from 6 February 2012) de Guidance Note on the Need for Planning Permission for the Development of Existing Houses and Flats (effective from 6 February 2012) Introduction The rules governing permitted development (that is, whether

More information

BUILDING SAFETY UNIT

BUILDING SAFETY UNIT POLICY Page 1 of 5 SUBMITTAL REQUIREMENTS FOR ONE AND TWO FAMILY DWELLINGS, ADDITIONS AND RENOVATIONS All submittals shall be site specific and designed to the provisions of the 2012 International Residential

More information

Getting the job done: Moving your gas supply. Why would I need to alter my gas supply? What to expect. Working on your property

Getting the job done: Moving your gas supply. Why would I need to alter my gas supply? What to expect. Working on your property Altering the position of your gas supply Moving your gas supply Northern Gas Networks owns all of the gas pipelines in the North East, most of Yorkshire and northern Cumbria, servicing 2.7 million customers.

More information

Tested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special)

Tested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special) THE B6 GLAZING SYSTEM GLAZING SYSTEMS FOR SEPTEMBER 2013 THE B6 HEEL BEAD SEAL SECURITY GLAZING SYSTEM Page 1 DESCRIPTION The B6 Heel Bead Seal Security Glazing System is suitable for installing all types

More information

The WANZ Guide to Window Installation

The WANZ Guide to Window Installation The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 2 of 60 Contents Overview 5 Objective 5 Scope 5 Opening Preparation 7 Step P1 Preliminary Check 8 Step P2 Cut the Underlay 9 Step

More information

Chapter 3 Pre-Installation, Foundations and Piers

Chapter 3 Pre-Installation, Foundations and Piers Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory

More information

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5 Accredited Construction Details (Scotland) 2010 For the limitation of thermal bridging and air infiltration in low and medium rise domestic buildings Introduction & Principles Issued in support of Junction

More information

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available. APR 1200 Acoustic Partition Roll CI/Sfb Ref: APR002 Glass mineral wool roll designed to provide high levels of sound insulation in walls and floors to meet Part E (England & Wales) and Section 5 (Scotland)

More information

CE66. Windows for new and existing housing

CE66. Windows for new and existing housing CE66 Windows for new and existing housing Contents Introduction 3 The BFRC Rating 4 Measuring window performance 4 Energy Saving Trust standards 5 General specifications 5 New housing 5 Energy Saving Trust

More information

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength. INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS Multi-Layer Technology provides increased strength. Specifically designed for interior applications. Compatible with most internal

More information

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs. Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12

More information

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01 Section Built-up Metal Roofs Rail and bracket system Product: Earthwool FactoryClad range Bu01 Standing seam system Product: Earthwool FactoryClad range and Earthwool Universal Slab Bu02 Built-up Metal

More information

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1 Top plate Stud Soffit lining 45mm min nog Fix scotia bead Building underlay/james Hardie rigid air barrier Soffit Detail Building underlay/james Hardie rigid air barrier Bottom plate 25mm wide cant strip.

More information

Residential Foundations and Basements

Residential Foundations and Basements Residential Foundations and Basements Disclaimer All of the following information is based on the 2006 International Residential Code with Kentucky Amendments. As some information is paraphrased, article

More information

Advice Series. the maintenance and repair of historic buildings

Advice Series. the maintenance and repair of historic buildings Advice Series the maintenance and repair of historic buildings Jacqui Donnelly - Architectural Conservation Advisor, Department of the Environment, Heritage & Local Government Current publications in the

More information

We re about to build.

We re about to build. We re about to build. Get out there boys! every new home is a possible new dinner menu! What do we need to know about dealing with termites? A Managed Approach is Best! There are more than three hundred

More information

Fact sheet 6: for farmers

Fact sheet 6: for farmers Fact sheet 6: for farmers Fuel Oil Storage February 2011 Are you planning to substantially alter your fuel oil store, or add a new one? If so, this fact sheet will help you meet the requirements of The

More information

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors Improving the flood resistance of your home Advice sheet 6: Flood-resilient This sheet provides guidance on identifying different types of floor, assessing the routes floodwater may enter, and describes

More information

Advantages and Disadvantages of Timber Frame Construction

Advantages and Disadvantages of Timber Frame Construction Appendix 1: Table A1.1 Advantages and Disadvantages of Timber Frame Construction Advantages of Timber Frame Construction Quick erection times Reduced site labour Reduced time to weather the structure Earlier

More information

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669 Report Date: 04/03/2014 Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669 About this Advisory Report Energy use in our homes is responsible for almost

More information

ECHO System for Basements

ECHO System for Basements ECHO System for Basements Homeowners looking for more space are all too familiar with the cold, damp and dingy basement. Now, the Enclosure Conditioned Housing (ECHO) System TM, winner of the Ottawa-Carleton

More information

Chapter 2 Basis of design and materials

Chapter 2 Basis of design and materials Chapter 2 Basis of design and materials 2.1 Structural action It is necessary to start a design by deciding on the type and layout of structure to be used. Tentative sizes must be allocated to each structural

More information

Monocouche Best Practice Guide. New-Build Housing Managing movement to avoid cracking

Monocouche Best Practice Guide. New-Build Housing Managing movement to avoid cracking Monocouche Best Practice Guide New-Build Housing Managing movement to avoid cracking Avoiding Cracking For The Designer Visible cracks in render are unsightly and although not hazardous to the construction

More information

Post and Beam Construction

Post and Beam Construction Post and Beam Construction A Presentation By the Canadian Wood Council Canadian Conseil Wood canadien Council du bois Early settlers introduced the concept of post and beam construction in North America

More information

9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards. Section 9.8. Stairs, Ramps, Handrails and Guards 9.8.1. Application 9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and

More information

INSTA-POLYPEARL CAVITY WALL INSULATION INSTA-POLYPEARL PLUS AND INSTA-POLYPEARL PLATINUM CAVITY WALL INSULATION

INSTA-POLYPEARL CAVITY WALL INSULATION INSTA-POLYPEARL PLUS AND INSTA-POLYPEARL PLATINUM CAVITY WALL INSULATION InstaFibre Ltd Insta House Ivanhoe Road Hogwood Business Park Finchampstead Wokingham Berkshire RG40 4PZ Tel: 0118 932 8811 Fax: 0118 932 8314 APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Flat 3 Dwelling type: Mid-floor flat 30, Brunswick Square Date of assessment: 23 September 2008 HOVE Date of certificate: 23 September 2008 BN3 1ED Reference number: 8398-6021-5510-4127-8022

More information

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012 2012 Ontario Building Code Requirements for New Construction Bradford West Gwillimbury Building Division March 5, 2012 1 Ontario Building Code changes Applicable to permits applied for after December 31,

More information

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability 1/9/13 By Brett T. Fagan, P.E. Presented by Marie Horan, P.E. Building Diagnostics, Inc. Building Diagnostics Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

More information

Chimneys in Thatched Properties

Chimneys in Thatched Properties Chimneys in Thatched Properties Compliance with Building Regulations when installing or repairing a chimney or re-thatching a roof that abuts a chimney The increasing problem of thatch fires Over the last

More information

DOMESTIC & GENERAL INSULATION LTD BLOWN-IN CAVITY WALL INSULATION THERMABEAD, THERMABEAD CARBON SAVER AND THERMABEAD DIAMOND CWI

DOMESTIC & GENERAL INSULATION LTD BLOWN-IN CAVITY WALL INSULATION THERMABEAD, THERMABEAD CARBON SAVER AND THERMABEAD DIAMOND CWI Domestic & General Insulation Ltd Units 1-2 Shipston Close Worcester WR4 9XN Tel: 0844 543 0043 Fax: 01432 268680 e-mail: headoffice@dgi.org.uk website: www.dgi.org.uk APPROVAL INSPECTION TESTING CERTIFICATION

More information

Residential Inspection Guidelines

Residential Inspection Guidelines Residential Inspection Guidelines 201 Pre-Pour Foundation Dimensions Building Location Certificate - if required in the building consent Construction and Advice Notes Check the building dimensions against

More information