Energy Efficiency E-modules - Guidance. Efficient Operation of HVAC Controls in the Public Sector

Size: px
Start display at page:

Download "Energy Efficiency E-modules - Guidance. Efficient Operation of HVAC Controls in the Public Sector"

Transcription

1 Energy Efficiency E-modules - Guidance Efficient Operation of HVAC Controls in the Public Sector

2 Efficient Operation of HVAC Controls in the Public Sector 2 Contents 1 Introduction 3 2 Learning Objectives and Outcomes Learning Objectives Learning Outcomes 3 3 HVAC Controls Overview The Scottish Building Standards Types of Control Systems and Features Time clocks Seven day multi-event programmable controller Optimised Start Weather Compensation Additional Control Features 6 4 Surveying Building Controls Energy Data Setpoints and Outputs The Design of the Control System User Display and Physical Control Components User Engagement 9 5 Efficient Operation of HVAC Controls in the Public Sector Maintenance Changes to the Control System Designing the Control System Zone Control Simultaneous heating and cooling Internal Sensors Occupancy control Building Energy Management Systems Other Design Considerations Commissioning of Building Controls Additional Features Variable Speed Controls Boiler Sequencing Control 12 6 Useful Links and References 13

3 Efficient Operation of HVAC Controls in the Public Sector 3 1 Introduction This guidance follows the format of the e-module Efficient Operation of HVAC Controls in the Public Sector and provides further details on the subjects covered in the module. Please note that module users working in a healthcare environment should always refer to the relevant Scottish Health Technical Memorandum (SHTM) prior to considering installation of the measures suggested in the module. The advice given in the SHTM may conflict with the advice given in this module, as it has been developed for the wider public sector. The relevant SHTM can be found on the Health Facilities Scotland website. 2 Learning Objectives and Outcomes 2.1 Learning Objectives The learning objectives for this module are to: Understand the different types of HVAC controls and their applications; and Understand typical issues which can lead to poor control of HVAC systems. 2.2 Learning Outcomes The learning outcomes for this project are to: Describe the basic principles explaining how different HVAC control systems work; Identity where different control systems are/should be used in Scottish public sector sites and buildings; Describe the main HVAC control technologies, including their typical capability and the advantages and disadvantages of each technology; Be able to identify basic HVAC control errors or malfunctions; Be able to carry out basic HVAC control alterations to meet the requirements of public sector buildings; Be able to prioritise the opportunities for improving control systems in public sector buildings; and Evaluate the key aspects in relation to HVAC control projects when building a business case.

4 Efficient Operation of HVAC Controls in the Public Sector 4 3 HVAC Controls Overview The HVAC controls, like any other aspect of building control, should ensure that a building operates safely and efficiently. Any control system operates essentially in three basic parts with: A sensor measuring some variable e.g. temperature; A controller which develops an output signal in response to the measured quantity; and A controlled device which is attempting to achieve some control set point. It is helpful to understand the main elements and features of a modern control system as part of being an effective energy manager is being able to spot when something has gone wrong with a control system. To consider how the building efficiency can be maximised, it is important to realise that alterations to, and failures in, building controls can have impacts on building user safety and comfort. Building control is a complex and specialist field so where there is uncertainty about what action to take in relation to a controls problem, it is always best to seek specialist guidance. Those control functions related to safety must always take precedence. One further point to consider is the potential for building user control. There is an ample body of evidence to suggest that building users experience a great improvement in physical and mental wellbeing where some level of user control is available. Where this is present, staff can frequently make do with or tolerate less than perfect environmental conditions, whereas if this is absent it can lead to continuous complaints and frequent readjustment of control with little perceived benefit. 3.1 The Scottish Building Standards The Scottish Building Standards sets out the minimum standards of control package for different types of HVAC systems. However it is important to realise that things can easily go wrong with control systems even when they are well designed and commissioned. Table 3.1 outlines the selected control requirements for boiler heating systems, taken from Section of the Energy Technical Handbook, Scottish Building Standard Table 3.1 Control requirements Boiler plant output and controls Less than 100kW (Package A) kW (Package B) Minimum controls Timing and temperature demand control which should be zonespecific where the building floor area is greater than 150m² Weather compensation except where a constant temperature supply is required Controls package A above plus: Optimal start/stop control is required with night set-back or frost protection outside occupied periods Boiler with two stage high/low firing facility or multiple boilers should be installed to provide efficient part-load performance For multiple boilers, sequence control should be provided and boilers, by design or application, should have limited heat loss from non-firing modules, for example by using isolation valves or dampers Individual boilers, by design or application, should have limited heat loss from non-firing boiler modules. For boilers that do not have low

5 Efficient Operation of HVAC Controls in the Public Sector 5 Boiler plant output and controls Minimum controls Greater than 500kW individual boilers (Package C) standing losses it may be necessary to install isolation valves or dampers Controls package A and B above plus: The burner controls should be fully modulating for gas-fired boilers and multi-stage oil-fired boilers 3.2 Types of Controllers and Features Control systems for HVAC systems can vary widely, from simple time clocks that are found on domestic type boilers, through to more advanced, programmable, seven day, multievent controllers. The next level of sophistication is a full Building Management System (BMS) that can use many different variables and inputs to control advanced multi-zone and multi-building HVAC systems. The complexity of controls is not always a good thing. However appealing a sophisticated approach might be, it is worth remembering that a simple system is likely to be easier and cheaper to maintain, repair and understand. This in turn might provide a lower risk route to maintaining good energy efficiency over a long period. Not surprisingly, simple HVAC systems tend to require a lesser degree of automation and complexity in their controls Time Clocks Controller Simple time clocks can take many forms. These include boiler mounted digital clocks, mechanical clocks and wall mounted digital clocks. These controllers tend to be associated with single items like boilers or ventilation fans and are generally only able to accommodate daily programmes. This means that the time settings will be repeated daily or weekly depending on manufacture. While the most basic controls will only switch the boiler or fan on and off in response to time settings, more advanced versions are able to control based on time and temperature, usually maintaining a temperature set-point during times when the controls are on Seven Day Multi-event Programmable Controller A seven day multi-event programmable controller is a more advanced type of controller. As the name suggests, this type incorporates multiple events over a period of seven days. For example, this type of controller would be appropriate for a small office where heating is required on weekdays but not at weekends, or where time schedules vary from day to day. As with the previous examples, this type of controller can also incorporate temperature setpoint controls, although they are generally still only capable of serving a single system or zone. Often, with these and other types of controllers, the temperature set-point is determined by a remote thermostat. These can be either fixed or adjustable. As well as heating systems, similar systems are used to control air conditioning systems Optimised Start Feature An optimised start feature automatically varies the system start time depending on the external temperature. For example, during warmer weather the system will activate the boilers a little later in the morning ensuring that the building achieves a set temperature by

6 Efficient Operation of HVAC Controls in the Public Sector 6 the time it is in use but minimising the time that the boiler is operating. This approach can be very useful where the occupancy is not continuous (e.g. offices and schools). An optimum start controller operates by learning the optimum operating conditions and so will take a period to bed in. During this period reactive adjustments to the control set points will detract from the ability of the controller to properly adapt. Optimised start (and in some cases optimised stop) functions can typically save 10% of overall heating consumption Weather Compensation Feature Weather Compensation varies the boiler flow temperature depending on the external air temperature. This is often achieved by a mixing valve placed near the boiler to control the maintained temperature and reduce the distribution losses from the system. In condensing boilers it can be possible to directly compensate or adjust the maintained boiler temperature. This has an added advantage as it allows the boiler to operate in condensing mode to achieve maximum heat recovery from the flue. The addition of weather compensation can often offer paybacks within a two year period Additional Features In larger buildings there may be additional features and a greater degree of complexity to include multiple boilers and several controllable heating zones. For wet systems there may be other local control features (e.g. thermostatic valves) as well as a number of items of plant to control. These might include Air Handling Units (AHUs), chillers and local air conditioning Building Management System Where there are multiple items of plant and multiple conditioned zones, it is likely that a BMS is likely to be needed to allow the plant to be controlled efficiently and economically. These incorporate central and local controllers capable of communication and programming. A BMS can include other functions like data logging of temperatures and energy monitoring.

7 Efficient Operation of HVAC Controls in the Public Sector 7 4 Surveying Building Controls It is important to assess the performance of controls in existing buildings. The following need to be considered when surveying building controls: 4.1 Energy Data As with any other deficiency in energy management, poor HVAC control will most likely manifest itself in a building s energy consumption. A good starting point is therefore to look for poor performance in relation to other similar buildings and published guides and for unexplained increases in consumption over time. Poorly controlled heating systems will have a weak correlation with actual heating requirement as expressed in degree days. For this reason a degree day analysis should be undertaken. Half hourly electrical (and in some cases fossil fuel data) may be available for buildings. It is often useful to compare equipment start times with that denoted in the BMS. A control problem can lead a plant to operate well beyond its core hours of operation. This can often be quickly identified using half hourly energy data. 4.2 Setpoints and Outputs The next area to check is the actual setpoints and outputs of the control system. In some cases the controls may be relatively intuitive; however in others it may be necessary to spend some time understanding the display functions of a particular manufacturer s boiler controller. Hidden problems can become quickly apparent once the operation of a particular controller or BMS is well understood. Check that the current setpoints and time schedules are appropriate for the way in which the building is being used. Over time, changes to work patterns can lead to different heating or cooling requirements. Unexpectedly high or low supply temperatures may indicate a broken heating control valve or potentially a faulty sensor. Either of these is likely to have a negative impact on the energy efficiency of the system or the comfort of the occupants. Often it is found that the controls are set up with a warm up time allowance added by the operator. However, many modern controllers will already aim to have the building at the right temperature during the time schedule. It may therefore be possible to reduce the operating hours of the system, further increasing efficiency. Some BMS systems include visual displays of the heating equipment. These can be useful in interpreting what is actually happening in the system at any given moment. For example, heating coils in an Air Handling Unit (AHU) activating during summer months could be indicative of a problem with their control. Data logging functions can include room temperature and supply air temperature, and how these outputs are changing over time. For example where a room is being heated or cooled outside of its expected hours of occupancy, this will usually be apparent in the overnight temperature. Depending on the nature of the systems this may also indicate other factors such as faults in the building fabric or frost protection system.

8 Efficient Operation of HVAC Controls in the Public Sector 8 Table 4.1 outlines the common faults in a BMS system. Table 4.1 Control requirements Fault Poor or excessive fabric and frost protection Passing heating and cooling batteries in AHU Simultaneous heating and cooling Comments This can be picked up on plots of internal temperature in individual spaces or boiler flow temperature Half hourly data of gas or electricity can show equipment activating very early or through weekends even in mild weather Possible problems may be the setpoints, the strategy or potentially the external or internal sensors Passing valves on heating or cooling batteries do not properly close and therefore are continually activated at low level. This is wasteful of the energy consumed at the central boilers or chillers and can also lead to simultaneous heating and cooling This can clearly be picked up on AHU visual displays where for example cool external air is warmed by an AHU battery (check before and after temperature) despite the battery output being at 0%. The valve or actuator will need to be repaired or replaced There are a range of potential solutions to this to include: Application of a dead band within which neither heating or cooling is provided Summer and winter changeover where heating and cooling central plant or circuits are deactivated Careful adjustment of ventilation supply air temperature to minimise the chance of reheating and re-cooling at terminal units 4.3 The Design of the Control System As well as the individual controller and control features it is worth considering how well designed and assembled the control systems are. A common problem in many buildings is simultaneous heating and cooling where one system tries to heat air only for another to cool it at a later stage. This problem may not be apparent in terms of occupant comfort but can only come from observation e.g. the control of heating and cooling batteries. It is worth considering whether the building controls match the guidance provided in the Building Standard Technical Standards for new and refurbished buildings. Many building controls are developed in a piecemeal fashion. As a result a large complex building might be served by many separate control systems. In these circumstances there will probably be the opportunity for improvement. 4.4 User Display and Physical Control Components Another activity that should be undertaken is to look at the physical control components and the control displays. While a BMS can be set up correctly, if the control valves it governs are broken then the desired level of control will never be achieved. Similarly physical observation of equipment as it operates over time can also be informative. For example, if the boilers are switching duty every two minutes, this could be an indication that the sequencing control has not been properly set up within the BMS. It is also worthwhile to look at the power and control panel settings. It is common to find equipment set to manual control which should be under automatic control.

9 Efficient Operation of HVAC Controls in the Public Sector User Engagement It is important to engage with the people who can have an impact on the building controls e.g. building users. Points to discuss are how they perceive the level of comfort in the building and how they use the local controls (including blinds and windows) available to them. Also consider if the occupants are contributing to energy wastage e.g. by switching off the Thermostatic Radiator Valves (TRV) in unoccupied rooms. It is good practice to become familiar with the features of individual controllers or BMS. Achieving this familiarity before the controls survey is undertaken will help to gain maximum benefit from this exercise. This will also help to identify instances where the input of a controls engineer is required. This might be to investigate a potential fault or to reprogram a control system (especially for complex systems). This specialist input might come from a term controls contractor who is responsible for the maintenance of the building controls, or there may be a controls specialist within the organisation. It may also be appropriate for key staff to undergo training on a particular control system type, particularly where this system is replicated or applied throughout the estate.

10 Efficient Operation of HVAC Controls in the Public Sector 10 5 Efficient Operation of HVAC Controls in the Public Sector 5.1 Maintenance A good controls strategy across an estate will greatly increase the energy efficiency of the building stock. The first point in any controls strategy is good maintenance. Controls tend to suffer disproportionately where maintenance is ignored or cut back. A gradual degradation in performance usually occurs which will affect occupant comfort, usability and efficiency. Regular checks and reviews of controls and control systems are strongly recommended. The need for maintenance should be considered when a control system is being selected. The maintenance of any system represents an ongoing cost and this cost rises as the complexity of the system increases. As a result, the complexity of the controls system should match the actual requirements. This approach will also reduce the costs of repair associated with component failure. 5.2 Changes to the Control System Even when overseeing a relatively small building stock, it is likely that there will be frequent changes and improvements to the buildings. Many of these will present the opportunity or requirement for changes to controls. It is therefore important to regularly review setpoint, timer control, temperature and other settings so that they match current and not past need. While your organisation might have a core specification for new control systems, it is worth considering if this is resulting in well performing systems. When reviewing a building control system, the following should be considered: Schematic diagram of the HVAC plant; Description of plant; Control strategy; Specification clauses; BMS setpoints list; Summary of plant operation; and Control flowchart. 5.3 Designing the Control System Zone Control Zone control might be considered as part of a HVAC strategy for a number of reasons including: Changing occupancy requirements; Different temperature requirements; The growing instances of multiple tenants; Different energy performance on different floors (particularly where top floors are poorly insulated); Building orientation that creates differences in heat gains and losses; More than one building on the heating circuit; and The obvious opportunities to create separate circuits in the heating system Simultaneous heating and cooling Simultaneous heating and cooling is a common fault and one which results in a needless waste of energy. This should be avoided or minimised in the control design. For instance some systems may incorporate a summer and winter time switchover setting for which the heating or cooling provisions are deactivated respectively.

11 Efficient Operation of HVAC Controls in the Public Sector Internal Sensors Poor placement of internal and external sensors can cause considerable problems for controls, both in terms of comfort and efficiency. Internal sensors should be placed in areas that are deemed representative of the actual space temperature and away from other heat sources. Thermostats for optimum start should be located in the coldest part of the building. External sensors should be place away from direct sunlight Occupancy control Occupancy control is another important feature of any design. Occupants should be given some control over their environment. However, while occupancy control should be part of the design of the control system, it should be limited so as not interfere with the overall control strategy and efficiency of the building Building Energy Management Systems Building Energy Management Systems (BEMS) are types of BMS or parts of a wider BMS strategy. These offer the facility to gather and monitor energy data and can be a useful tool especially in buildings with substantial and complex HVAC requirements. BEMS can lead to energy savings of 10% to 20% compared to a system based on a collection of local controllers Other Design Considerations Complexity in a control system is not necessarily a good thing. For example, too many heating zones or overly sophisticated strategies may discourage the building users from using the controls effectively. Simple systems well matched to the building requirements will offer reduced maintenance costs, lower incidence of failure and lower capital cost. The user interface should be simple, intuitive and easily interpreted, even by users who are unaware of the control strategy. The building HVAC controls do not operate in isolation. They are part of the overall building services providing a safe and comfortable working environment. Therefore the efficiency of the controls will depend on other aspects of the HVAC design. For example if the boiler equipment is oversized, no matter how well the control system is designed, it will be difficult to ensure it operates efficiently. Components for BMS systems can quickly become obsolete depending on a number of factors including whether the manufacturer or vendor can continue to support the system with spare parts. It is important to consider these points at the outset of any procurement process, as it can be difficult to undertake repairs and maintenance on a system without the support of the original manufacture. 5.4 Commissioning of Building Controls Another point often overlooked or left partially complete is the commissioning of building controls. In specifying HVAC controls it is important to refer to or stipulate adherence to the Chartered Institute of Building Services Engineers Commissioning Code C. Many buildings never achieve their full energy saving potential through their controls due to poor commissioning.

12 Efficient Operation of HVAC Controls in the Public Sector Additional Features Variable Speed Controls A common energy saving measure included in many control systems for ventilation and air based heating systems is the use of variable speed control. This is usually applied via an inverter drive to motors serving fans and pumps. The relationship between fan power and fan flow is cubic, so any reduction in fan flow results in a proportionately far greater reduction in power demand. The fan efficiency laws are summarised in the equation, where P is Power in kw and Q is airflow in m³/sec: Inverter or variable speed drives (VSDs) provide a control solution to take advantage of this effect. When fans are oversized and the actual demand for ventilation is low or when the building use changes, there may be potential to reduce fan speed. In some cases it may be best to apply a fixed reduction (i.e. VSD at fixed output). In others the requirement for ventilation may vary a great deal through each day in which case a more sophisticated strategy could be employed to include occupancy sensing control through a PIR or CO 2 sensor. With this latter approach, the energy consumed by fans and by any heating providing temperature control of the supplied air can be greatly reduced Boiler Sequencing Control For multi boiler systems, one of the more common potential failings is poor sequencing control, so this can often be a good improvement for existing buildings. Boilers or assemblies of boilers often operate inefficiently when they deal with low thermal loads. This is either because of the heat losses through the boiler casing or the process of purging any combustion gas in the heat exchanger when they fire. Where this happens continuously, the losses through the flue can be substantial. Sequencing controls ensure that the boilers are brought on and off load in the most efficient manner. Sequencing controllers can come as stand-alone units which can bolt on to existing systems and modern BMS systems often have some level of sequencing control (although it may not be correctly set up). Larger sequencing systems may include isolation valves for each boiler to allow these to be hydraulically separated when offline and prevent casing losses. For existing buildings, boilers frequently coming on and off load may be an indication that the sequencing control could be improved.

13 Efficient Operation of HVAC Controls in the Public Sector 13 6 Useful Links and References Title Source Link Zero Waste Scotland Resource Efficient Scotland Heating control technology guide (CTG065) The Carbon Trust How to implement heating zone controls (CTL148) How to implement boiler sequence controls (CTL144) How to implement air quality sensors (CTL059) How to implement thermostatic radiator valves (CTL040) How to implement optimum start control (CTL035) Control strategies for Low Carbon Buildings CIBSE Guide H: Building Control Systems The Carbon Trust The Carbon Trust The Carbon Trust The Carbon Trust The Carbon Trust University of Exeter The Chartered Institute of Building _heating_zone_controls_aw.pdf _boiler_sequence_control_aw.pdf ity_aw interactive.pdf or_valves_aw.pdf um_start_control.pdf lchsmodule1notes/control_strategies.pdf

14 Efficient Operation of HVAC Controls in the Public Sector 14 Services Engineers CIBSE Commissioning Code C The Chartered Institute of Building Services Engineers Building Standards Handbook Mon Domestic Section Efficiency of MVAC equipment Scottish Government

15 Efficient Operation of HVAC Controls in the Public Sector 15

The Business Case Annual fuel cost savings of 26% worth more than 28,000 Annual fuel savings of 1.3million kwh Annual CO2 savings of over 245 tonnes

The Business Case Annual fuel cost savings of 26% worth more than 28,000 Annual fuel savings of 1.3million kwh Annual CO2 savings of over 245 tonnes North Lanarkshire Council The Business Case Annual fuel cost savings of 26% worth more than 28,000 The Sir Matt Busby Sports Complex is an important local facility for the people of Bellshill, North Lanarkshire.

More information

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues Design Guide Retrofitting Options For HVAC Systems In Live Performance Venues Heating, ventilation and air conditioning (HVAC) systems are major energy consumers in live performance venues. For this reason,

More information

GAS HEATING IN COMMERCIAL PREMISES

GAS HEATING IN COMMERCIAL PREMISES ENERGY EFFICIENCY OFFICES GAS HEATING IN COMMERCIAL PREMISES www.energia.ie www.energia.ie Typically, energy reductions of 10% or more can be made easily through maintenance and low cost improvements.

More information

Using Building Energy Management Systems (BEMS) Best Practice for Energy and Carbon Savings.

Using Building Energy Management Systems (BEMS) Best Practice for Energy and Carbon Savings. Using Building Energy Management Systems (BEMS) Best Practice for Energy and Carbon Savings. Paul Connor EngTechTMEI and Paul Butler EngTechTMEI Energy Consultant s Housekeeping and Introduction. None

More information

Energy Efficiency E-module - Guidance. Efficient Operation of Low Temperature Hot Water Boilers in the Public Sector

Energy Efficiency E-module - Guidance. Efficient Operation of Low Temperature Hot Water Boilers in the Public Sector Energy Efficiency E-module - Guidance Efficient Operation of Low Temperature Hot Water Boilers in the Public Sector Efficient Operation of Low Temperature Hot Water Boilers in the Public Sector 2 Contents

More information

CONTROL STRATEGIES FOR HVAC SYSTEMS

CONTROL STRATEGIES FOR HVAC SYSTEMS CONROL SRAEGIES FOR HVAC SYSEMS ZBIGNIEW POPIOLEK Department of Heating, Ventilation and Dust Removal echnology Silesian University of echnology, Poland 1 Definition of control: to apply a regulating influence

More information

HEATING, VENTILATION & AIR CONDITIONING

HEATING, VENTILATION & AIR CONDITIONING HEATING, VENTILATION & AIR CONDITIONING as part of the Energy Efficiency Information Grants Program Heating and cooling can account for approximately 23 % of energy use in pubs and hotels 1. Reducing heating

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-23 09 93 (November 2015) ----------------------------- Preparing Activity: USACE Superseding UFGS-23 09 23 (May 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

Automated Commissioning for Energy (ACE) Platform for Large Retail Property. Overview

Automated Commissioning for Energy (ACE) Platform for Large Retail Property. Overview Automated Commissioning for Energy (ACE) Platform for Large Retail Property $62,900 dollars of energy savings identified during the first 6 weeks Overview The ability to pull large amounts of complex data

More information

AIR COOLED CHILLER CHILLED WATER PUMP CONTROL: The chilled water pump with the lowest runtime will automatically start when the outside air temperature rises above the system enable setpoint. When the

More information

HVAC Processes. Lecture 7

HVAC Processes. Lecture 7 HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump

More information

Boiler efficiency for community heating in SAP

Boiler efficiency for community heating in SAP Technical Papers supporting SAP 2009 Boiler efficiency for community heating in SAP Reference no. STP09/B06 Date last amended 26 March 2009 Date originated 28 May 2008 Author(s) John Hayton and Alan Shiret,

More information

Operating instructions

Operating instructions Operating instructions Gas condensing boilers MGK-130 MGK-170 MGK-210 MGK-250 MGK-300 Wolf GmbH Postfach 1380 D-84048 Mainburg Tel. +49 8751/74-0 Fax +49 8751/741600 Internet: www.wolf-heiztechnik.de Document

More information

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents

More information

Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump

Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump The basics... This guide can help you make an informed

More information

Energy Efficiency HOSPITALITY. www.energia.ie

Energy Efficiency HOSPITALITY. www.energia.ie Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real

More information

Scope of Work. See www.sei.ie for resources available

Scope of Work. See www.sei.ie for resources available HVAC SWG Summary Background Pool energy-efficiency knowledge Increase cost-competitiveness Develop resources aimed at assisting in reducing HVAC energy consumption Address barriers to energy-saving HVAC

More information

Condensing Boiler Efficiency

Condensing Boiler Efficiency Condensing Boiler Efficiency Date: July 17, 2012 PRES E NT ED BY DO N L E O NA RDI LE O N A RD I I NC. HV AC T RAI N I N G & C ON SU LT IN G Concepts 1 The current state of evolution in boiler design 2

More information

Energy Saving Tips. Adjust set point temperature up a few degrees... Window contact. Occupancy sensor. A Programmable Thermostat

Energy Saving Tips. Adjust set point temperature up a few degrees... Window contact. Occupancy sensor. A Programmable Thermostat Energy Saving Tips Nowadays when Energy costs are skyrocketing and the awareness to environmental issues is increasing, we all want to reduce energy consumption and have a greener lifestyle. Heating &

More information

Energy Efficiency. Bars & RestauRants. www.energia.ie

Energy Efficiency. Bars & RestauRants. www.energia.ie Energy Efficiency Bars & RestauRants www.energia.ie 2 Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could

More information

Heating, ventilation and air conditioning (HVAC) equipment. A guide to equipment eligible for Enhanced Capital Allowances

Heating, ventilation and air conditioning (HVAC) equipment. A guide to equipment eligible for Enhanced Capital Allowances Heating, ventilation and air conditioning (HVAC) equipment A guide to equipment eligible for Enhanced Capital Allowances 2 Contents Boost Introduction your cash flow 03 1. Background Check it s on the

More information

Heating, ventilation and air conditioning equipment. A guide to equipment eligible for Enhanced Capital Allowances

Heating, ventilation and air conditioning equipment. A guide to equipment eligible for Enhanced Capital Allowances Heating, ventilation and air conditioning equipment A guide to equipment eligible for Enhanced Capital Allowances 2 Contents Introduction 03 Background 03 Setting the scene 03 Benefits of purchasing ETL

More information

Using Time-of-Day Scheduling To Save Energy

Using Time-of-Day Scheduling To Save Energy The following article was published in ASHRAE Journal, May 29. Copyright 29 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. It is presented for educational purposes only.

More information

Draft UCL Heating, Cooling and Ventilation Policy

Draft UCL Heating, Cooling and Ventilation Policy Draft UCL Heating, Cooling and Ventilation Policy Page 1 of 7 UCL Estates UCL Heating, Cooling & UCL Heating, Cooling and Document Owner UCL Estates Leadership Team is the Owner of this document. Distribution

More information

Printing and Publishing Energy Savings Guide

Printing and Publishing Energy Savings Guide Printing and Publishing Energy Savings Guide Oregon printing and publishing plants face challenges of rising operating costs, environmental and other regulations, outdated equipment and customer demand

More information

FIELD TESTS OF FUEL EFFICIENCY MAGNETS J A CRABB JULY 1997 SWEEG REPORT 80

FIELD TESTS OF FUEL EFFICIENCY MAGNETS J A CRABB JULY 1997 SWEEG REPORT 80 FIELD TESTS OF FUEL EFFICIENCY MAGNETS J A CRABB JULY 1997 SWEEG REPORT 80 List of symbols T f average temperature at the flow header, C T r average temperature at the return header, C f average water

More information

A Class Air Source Heat Pump User Guide

A Class Air Source Heat Pump User Guide A Class Air Source Heat Pump User Guide IMPORTANT THIS MANUAL MUST BE LEFT WITH THE USER AFTER INSTALLATION 8/60476/0 Issue 1.03 Contents 1: Introduction 1 2: How the Heat Pump Works 1 2.1 Tips and advice

More information

Heating, ventilation and air conditioning zone controls

Heating, ventilation and air conditioning zone controls Technology information leaflet ECA762 Heating, ventilation and air conditioning zone controls A guide to equipment eligible for Enhanced Capital Allowances Contents Introduction 01 Background 01 Setting

More information

Connolly Hospital Blanchardstown makes rapid recovery on energy technology investment

Connolly Hospital Blanchardstown makes rapid recovery on energy technology investment Connolly Hospital Blanchardstown makes rapid recovery on energy technology investment Connolly Hospital, Blanchardstown (CHB) is a major teaching hospital and provides medical, surgical and support services

More information

Example Retrocommissioning Measure: Opening Throttled Discharge Valves

Example Retrocommissioning Measure: Opening Throttled Discharge Valves Opening Throttled Discharge Valves This 21-story building, constructed in 1997, is located in Oregon and contains 589,000 gross square feet of mostly office occupancy. The HVAC system includes six large

More information

State of the Art Energy Efficient Data Centre Air Conditioning

State of the Art Energy Efficient Data Centre Air Conditioning - White Paper - State of the Art Energy Efficient Data Centre Air Conditioning - Dynamic Free Cooling - Release 2, April 2008 Contents ABSTRACT... 3 1. WHY DO I NEED AN ENERGY EFFICIENT COOLING SYSTEM...

More information

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation. 1.1.1 The Building Regulations 2010

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation. 1.1.1 The Building Regulations 2010 EFA PSBP Natural Ventilation Strategy Introduction The Baseline Designs Project will provide scheme design details for a number of Primary and Secondary School Exemplars. For the purposes of setting a

More information

ASTACEA4 Inspect complex/central air conditioning systems

ASTACEA4 Inspect complex/central air conditioning systems Overview This Unit covers the competences required to inspect complex/central air conditioning systems as defined by the CIBSE TM 44 Figure 1.1: Summary of system types and their component parts. The air

More information

Non-Domestic Building Services Compliance Guide

Non-Domestic Building Services Compliance Guide Non-Domestic Building Services Compliance Guide 2013 edition for use in England* * Note: Any reference to the Building Regulations in this guide is to the Building Regulations 2010 in England (as amended).

More information

The ABB i-bus KNX Room Master Concept Your first step into the KNX world

The ABB i-bus KNX Room Master Concept Your first step into the KNX world The ABB i-bus KNX Room Master Concept Your first step into the KNX world The Room Master Concept 1 New Step 1,000 New Options You specialize in installing electrical systems. With the ABB Room Master,

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Flat 3 Dwelling type: Mid-floor flat 30, Brunswick Square Date of assessment: 23 September 2008 HOVE Date of certificate: 23 September 2008 BN3 1ED Reference number: 8398-6021-5510-4127-8022

More information

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now Fact Sheet #6 Air Conditioning In this fact sheet you will discover: The opportunity for energy efficiency How air conditioning works Low cost actions to reduce energy usage now Investments to reduce costs

More information

Infrastructure & Cities Sector

Infrastructure & Cities Sector Technical Article Infrastructure & Cities Sector Building Technologies Division Zug (Switzerland), October 18, 2011 Saving Energy in a Data Center A Leap of Faith? New guidelines from ASHRAE (American

More information

OEH Energy Efficient HVAC for Business Training Course

OEH Energy Efficient HVAC for Business Training Course OEH Energy Efficient HVAC for Business Training Course www.environment.nsw.gov.au/training Presenter: Chris Warris, BCW Carbon and Energy Agenda for Today Overview of OEH Energy Efficiency Training Program

More information

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL

More information

Drayton Digistat +2RF

Drayton Digistat +2RF Drayton Digistat +2RF T Programmable Room Thermostat Wireless 24 Hour Model: RF700/22090 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130

More information

Priority Actions for Improving. Energy Efficiency across the

Priority Actions for Improving. Energy Efficiency across the Priority Actions for Improving Energy Efficiency across the Government Estate September 2010 1 Table of Contents Overview... 3 Theme 1 - Identifying Usage... 3 KEY ACTION 1: Identify and implement an optimal

More information

The sample report format is applicable to many different building types and systems and the examples provided cover a variety of applications.

The sample report format is applicable to many different building types and systems and the examples provided cover a variety of applications. Purpose Power Smart s Minimum Requirements for an Energy Study (see Appendix) provides a comprehensive list of the basic elements which must be included in an Energy Study Report. The intent of this sample

More information

Impact of Control System Technologies on Industrial Energy Savings

Impact of Control System Technologies on Industrial Energy Savings Impact of Control System Technologies on Industrial Energy Savings Priyam Parikh Industrial Assessment Center Texas A&M University Bryan P. Rasmussen Industrial Assessment Center Texas A&M University http://farolconsulting.com/?page_id=110

More information

Fundamentals of HVAC Control Systems

Fundamentals of HVAC Control Systems ASHRAE Hong Kong Chapter Technical Workshop Fundamentals of HVAC Control Systems 18, 19, 25, 26 April 2007 2007 ASHRAE Hong Kong Chapter Slide 1 Chapter 5 Control Diagrams and Sequences 2007 ASHRAE Hong

More information

RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary

RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary January 2013 TABLE OF CONTENTS INTRODUCTION... 3 GENERAL RECOMMENDATIONS... 3 Communication with customers in the field of environmental sustainability...

More information

Domestic Heating Energy Savings with Better Controls

Domestic Heating Energy Savings with Better Controls Domestic Heating s with Better Controls Martin O Hara Danfoss Randall Limited, Ampthill Road, Bedford, MK42 9ER, England Abstract: This paper presents results of system testing with 3 different domestic

More information

Sample - Existing Building Commissioning Plan

Sample - Existing Building Commissioning Plan Sample - Existing Building Commissioning Plan Version: Draft for Review Final Approved: Owner Site Address: Primary Site Contact Name and Telephone Number: Date Building Description The site consists of

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

Case Studies: Infrared Heating in Industrial Applications

Case Studies: Infrared Heating in Industrial Applications Case Studies: Infrared Heating in Industrial Applications Chao Chen, Puget Sound Energy ABSTRACT Puget Sound Energy (PSE) is a utility which serves more than one million electric customers and over 700,000

More information

Common Boiler Excess Air Trends and Strategies to Optimize Efficiency

Common Boiler Excess Air Trends and Strategies to Optimize Efficiency Common Boiler Excess Air Trends and Strategies to Optimize Efficiency Kevin Carpenter and Chris Schmidt, Energy & Resource Solutions Kelly Kissock, University of Dayton ABSTRACT Boilers are among the most

More information

Mechanical Systems Proposal revised

Mechanical Systems Proposal revised Mechanical Systems Proposal revised Prepared for: Dr. William Bahnfleth, Professor The Pennsylvania State University, Department of Architectural Engineering Prepared by: Chris Nicolais Mechanical Option

More information

Baxi Combi 80e & 105e

Baxi Combi 80e & 105e Baxi Combi 8e & 15e Please keep these instructions safe. Should you move house, please hand them over to the next occupier. Gas Fired Wall Mounted Combination Boiler User s Operating Instructions Natural

More information

5.6 Technical Specification: Premium Efficiency Electric Air Conditioning Equipment

5.6 Technical Specification: Premium Efficiency Electric Air Conditioning Equipment 5.6 Technical Specification: Premium Efficiency Electric Conditioning Equipment Small Premium Project Type: For Premium Conditioning Retrofit Projects: Projects that voluntarily replace existing unitary

More information

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

RVL470. Heating Controller. Building Technologies HVAC Products. Series B 2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones

More information

ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM

ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM J.S. Hu, Philip C.W. Kwong, and Christopher Y.H. Chao Department of Mechanical Engineering, The Hong Kong University of Science and Technology Clear Water Bay,

More information

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler User s Operating Instructions & Important Warranty Information Baxi Platinum Combi HE Range Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move house,

More information

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX Content Heating / Ventilation / Air Conditioning 3 The Right Room Climate 4 Optimised Energy Efficiency and well-being Room

More information

Energy efficiency in building automation and control

Energy efficiency in building automation and control Energy efficiency in building automation and control Proven applications for heating and cooling supply Answers for infrastructure. Efficient VAC control protects the environment and increases comfort

More information

Commissioning - Construction Documents (Page 1 of 6)

Commissioning - Construction Documents (Page 1 of 6) Commissioning - Construction Documents (Page 1 of 6) A. General Information Climate Zone: Building Type: Conditioned Area (sf): Reviewer's Name: Reviewer's Agency: Note: Design Review for each system/subsystem

More information

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM AIR HANDLING UNITS... 1 CHILLERS... 2 COOLING TOWERS... 2 CLOSED LOOP COOLERS... 2 MISCELLANEOUS SUPPLY FANS...

More information

A. The Commissioning Authority (CxA) has been contracted or will be contracted directly with the Owner for this project.

A. The Commissioning Authority (CxA) has been contracted or will be contracted directly with the Owner for this project. DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION 23 08 02 PART 1 GENERAL 1.01 AUTHORITY (CxA) A. The Commissioning Authority (CxA) has been contracted or will be contracted directly

More information

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Certification Mark GB Installation and GB Index Index Installation Instructions 3-14 Product Specification

More information

Information Guide Domestic Air Source Heat Pumps

Information Guide Domestic Air Source Heat Pumps Information Guide Domestic Air Source Heat Pumps Issue 41 Domestic Air Source Heat Pumps This is an independent guide produced by Mitsubishi Electric to enhance the knowledge of its customers and provide

More information

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure. LMS The modular management system for condensing boilers Control Products & Systems OEM Answers for infrastructure. LMS advanced electronics and proven software At times of dwindling resources, rising

More information

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler User s Operating Instructions Baxi Combi 130 HE Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move house, please hand them over to the next occupier.

More information

HVAC Systems: Overview

HVAC Systems: Overview HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct

More information

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser FITTING AND OPERATING INSTRUCTIONS FOR DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM General information is given in the users instruction leaflet despatched with the appliance and/or on

More information

Energy Saving Fact Sheet Boilers

Energy Saving Fact Sheet Boilers Energy Saving Fact Sheet Boilers Turn a burning issue into real energy savings You need a boiler to heat your premises and provide hot water or to generate steam for use in industrial processes. Unfortunately,

More information

When considering your heating options, keep in mind that 60% of your energy. costs are attributed to space heating. You

When considering your heating options, keep in mind that 60% of your energy. costs are attributed to space heating. You Heating Options Furnaces & Boilers September 2005 CONSUMERS GUIDE - TO HOME HEATING OPTIONS CONTENTS Heat Distribution Energy Source Boilers Proper Sizing Energy Efficiency - Standards - Rating System

More information

Ener.co & Viridian Energy & Env. Using Data Loggers to Improve Chilled Water Plant Efficiency. Randy Mead, C.E.M, CMVP

Ener.co & Viridian Energy & Env. Using Data Loggers to Improve Chilled Water Plant Efficiency. Randy Mead, C.E.M, CMVP Ener.co & Viridian Energy & Env. Using Data Loggers to Improve Chilled Water Plant Efficiency Randy Mead, C.E.M, CMVP Introduction Chilled water plant efficiency refers to the total electrical energy it

More information

Rev. No. 0 January 5, 2009

Rev. No. 0 January 5, 2009 ENERGY & ENVIRONMENTAL ENERGY ISSUES COMMITTEE 415 Main Building Telephone (574) 631-6666 Notre Dame, Indiana Facsimile (574) 631-5883 46556 USA Energy Conservation Plan For HVAC Systems Rev. No. 0 January

More information

Variable Air Volume - VAV

Variable Air Volume - VAV Mode Enable Sensor Options Variable Air Volume - VAV The temperature of this sensor will determine if the unit is in heating, cooling or vent mode during occupied operation. The following options are available:

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL CONTENTS HOW YOUR SYSTEM WORKS......... 2 COOLING CYCLE....................... 2 HEATING CYCLE (HEAT PUMPS).......... 2 SYSTEM OPERATION................... 2 SETTING THE THERMOSTATS............ 2 THERMOSTATS.....................

More information

Building Energy Systems. - HVAC: Heating, Distribution -

Building Energy Systems. - HVAC: Heating, Distribution - * Some of the images used in these slides are taken from the internet for instructional purposes only Building Energy Systems - HVAC: Heating, Distribution - Bryan Eisenhower Associate Director Center

More information

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries Hot tips and cool ideas to save energy and money! Air conditioning units or systems are often used by foundries

More information

Tips on Saving Energy in Your Business

Tips on Saving Energy in Your Business Fact Sheet #3 Tips on Saving Energy in Your Business In this fact sheet you will discover: Quick and easy changes to save energy. Cost effective ways to reduce your heating, cooling, lighting and office

More information

Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains

Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation

More information

for Plans Examiners and Building Inspectors

for Plans Examiners and Building Inspectors Building Technologies Program HVAC Controls Guide for Plans Examiners and Building Inspectors September 2011 Authors: Eric Makela, PNNL James Russell, PECI Sarah Fujita, PECI Cindy Strecker, PECI Prepared

More information

red zone management white paper Making the most of Distribution Use of System (DUoS) Charges

red zone management white paper Making the most of Distribution Use of System (DUoS) Charges red zone management white paper Making the most of Distribution Use of System (DUoS) Charges 1. Distribution charges 2. Measuring usage 3. Component parts 4. Time is of the essence 5. Solution provider

More information

The District Energy Manager and Classroom Heating

The District Energy Manager and Classroom Heating Mt. Carmel Area School District Energy Conservation Policy Adopted 6/19/06 These guidelines supersede all previous instructions. It is crucial that these energy guidelines be observed in the operation

More information

8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en

8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en 8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................

More information

University Of London - Heating and Cooling Policy

University Of London - Heating and Cooling Policy University Of London - Heating and Cooling Policy The reason for the policy The University of London is obligated to comply with energy reduction targets set by Higher Education Funding Council for England

More information

HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY

HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY Benson Kwong, CVS, PE, CEM, LEED AP, CCE envergie consulting, LLC Biography Benson Kwong is an independent consultant providing

More information

Applying Schedules and Profiles in HAP

Applying Schedules and Profiles in HAP This HAP e-help discusses the importance of properly applying schedules and profiles in HAP. We will also discuss potential misapplications of these user inputs. First, we need to understand the differences

More information

CHAPTER 8 HVAC (Heating, Ventilation, and Air-Conditioning)

CHAPTER 8 HVAC (Heating, Ventilation, and Air-Conditioning) CHAPTER 8 HVAC (Heating, Ventilation, and Air-Conditioning) Objectives Survey current HVAC system(s), operating procedures, and maintenance schedule. Analyze results of energy audit for HVAC system(s)

More information

ENHANCED LABORATORY HVAC SYSTEM

ENHANCED LABORATORY HVAC SYSTEM ENHANCED LABORATORY HVAC SYSTEM INTRODUCTION Since the early 1980's the attention to more energy efficient laboratory designs has been on the rise due to the increase in energy cost and the emergence of

More information

AQUACIAT2 HYBRID THE COMPACT DUAL-ENERGY SOLUTION HEAT PUMP & GAS BOILER. Cooling and heating capacities of 45 to 80 kw AVAILABLE 2 ND QUARTER OF 2014

AQUACIAT2 HYBRID THE COMPACT DUAL-ENERGY SOLUTION HEAT PUMP & GAS BOILER. Cooling and heating capacities of 45 to 80 kw AVAILABLE 2 ND QUARTER OF 2014 AVAILABLE 2 ND QUARTER OF 2014 HEAT PUMP & GAS BOILER C O M F O R T A I R Q U A L I T Y E N E R G Y O P T I M I S A T I O N AQUACIAT2 HYBRID Cooling and heating capacities of 45 to 80 kw THE COMPACT DUAL-ENERGY

More information

Building Management Systems

Building Management Systems Building Management Systems Summary A well designed and managed Building Management System (BMS) provides great opportunities for improvements in energy efficiency by: Enabling building managers to provide

More information

2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT

2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT Presentation Synopsis Heating, Ventilating and Air Conditioning Building Condition Assessment Vancouver, B.C. Prepared for: EPIC Prepared by: Douglas Spratt, P.Eng Douglas Spratt & Associates Ltd. www.dspratt-associates.com

More information

Best Practice Guide BPGCS007

Best Practice Guide BPGCS007 Best Practice Guide BPGCS007 ENERGY MANAGEMENT Introduction: With rising fuel costs, opening of electricity and gas markets to alternate suppliers and climate change, the requirement to monitor and reduce

More information

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings. 1100 & 1400 Energy Controllers Satchwell 1100 & 1400 for energy-efficient temperature control in smaller buildings. 02 1100 & 1400 Energy Controllers Features he 1100 and 1400 Energy Controllers are self-configuring

More information

Saving Energy For Your Organisation. Top 10 energy saving tips

Saving Energy For Your Organisation. Top 10 energy saving tips Saving Energy For Your Organisation Top 10 energy saving tips How can you increase efficiency, reduce costs and cut your carbon emissions? The UK s Climate Change Act (2008) sets a legally-binding target

More information

Electronic Diesel Control EDC 16

Electronic Diesel Control EDC 16 Service. Self-Study Programme 304 Electronic Diesel Control EDC 16 Design and Function The new EDC 16 engine management system from Bosch has its debut in the V10-TDI- and R5-TDI-engines. Increasing demands

More information

ABERDEEN CITY COUNCIL. Communities, Housing and Infrastructure

ABERDEEN CITY COUNCIL. Communities, Housing and Infrastructure ABERDEEN CITY COUNCIL COMMITTEE Communities, Housing and Infrastructure DATE 20 th January 2016 DIRECTOR TITLE OF REPORT REPORT NUMBER CHECKLIST COMPLETED Pete Leonard Buildings Performance Policy CHI/15/256

More information

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...

More information

building engineering services association specification for: Domestic Heating www.thebesa.com

building engineering services association specification for: Domestic Heating www.thebesa.com building engineering services association specification for: Domestic central Heating installation www.thebesa.com building engineering services association acknowledgments Guide to good practice: Domestic

More information

Winter heating This winter heating guide includes ways to reduce heating costs and provides advice on choosing the right heater to suit your needs.

Winter heating This winter heating guide includes ways to reduce heating costs and provides advice on choosing the right heater to suit your needs. Winter heating This winter heating guide includes ways to reduce heating costs and provides advice on choosing the right heater to suit your needs. Fuel for thought Choosing the right heating system for

More information

KNX for building and room automation simple and efficient

KNX for building and room automation simple and efficient The worldwide standard for home and building control KNX for building and room automation simple and efficient Save energy and effort with a comprehensive portfolio for electrical and HVAC applications.

More information