FIRE SERVICES GUIDELINE Open Air Storage of New or Used Tyres
|
|
|
- Bryan Caldwell
- 9 years ago
- Views:
Transcription
1 FIRE SERVICES GUIDELINE Open Air Storage of New or Used Tyres 1. PURPOSE 1.1 The primary purpose of this guideline is to provide advice and to make recommendations for the safe storage of new or used rubber tyres on sites in the open air. It also serves to assist operational fire fighters to be aware of the issues that may affect their standard operational procedures. 1.2 This guideline is aimed specifically at operators to help them run the sites as safely as possible, and to ensure that fire protection is provided based on accepted engineering principles, tests, data, fire incidents and field experience. 1.3 This guideline has been produced for advisory purposes only, and does not establish a binding legal or regulatory scheme in respect of the safe storage of tyres. 2. SCOPE 2.1 This guideline is suitable for all sites within Victoria that store, or plan to store, new or used tyres in the open air. Advice and recommendation s pertaining to indoor storage of new and used rubber tyres, is included in Fire Services Guideline - Indoor Storage of New or Used Tyres. [Bibliography Ref 7.1] 3. BACKGROUND - Fire and Environmental Hazards 3.1 Rubber tyres are made of compounds that cause rapid combustion, including carbon, oil, benzene, toluene, rubber, and sulphur. While, tyres are not easy to ignite because they are designed to absorb the heat generated by the friction of road contact, once ignition takes place, this same ability of tyres to absorb heat makes extinguishment difficult. The high carbon content and steel cords serve as a heat sink, absorbing and storing heat within the tyre. Although extinguishment process cools the tyre from open flaming to a smouldering stage, the stored tyre heat can re-ignite the tyres. 3.2 Tyres have a heat of combustion of about 35kJ/g, or roughly twice that of ordinary combustibles such as paper or wood. Once ignited, fire development is rapid and high temperatures can be expected due to the large exposed surface area of tyre piles and the available ventilation. Burning is likely to persist for extended periods. In all fires there is a high probability of re-ignition of the tyre pile, even if the fire is controlled. 3.3 While Tyres are stable and not considered to be a hazardous material, once there is a fire, the tyre product breaks down into hazardous compounds including gases, heavy metals, and oil, generating a great deal of smoke. Experience at large tyre fires in the US indicates that for every million tyres consumed by fire, approximately 208,000 litres of unburned run-off oil can pollute the environment unless contained. The average passenger car tyre is estimated to produce more than 7.5 litres of oil. Tyre fire run-off is a significant environmental pollutant that can get into ground water and contaminate well water. In addition to run-off oil, at least 32 toxic gases are produced by tyre fires. [Bibliography Ref 7.2] March 2014 Version 5 Page 1
2 3.4 Storage and stacking arrangements of rubber tyres create difficult challenges for fire fighting, since the tyres hollow toroidal (hollow doughnut shaped) form provides ventilation and allows flames to grow on its inner surface while at the same time shielding flames from sprinkler and fire hose spray. [Bibliography Ref 7.2 & 7.3] 3.5 The many ways tyres may be stored outdoors make it impossible to apply any single or set of rules that cover all circumstances adequately. In general the provision of automatic fire protection is impractical for outdoor storage. Emphasis is therefore placed upon: Adequate separation distance from site boundaries and buildings to resist the spread of fire Where in a Bushfire Prone Area (BPA) adequate bushfire protection, with the design limiting received radiant heat flux level from a passing bushfire to a maximum of 12.5 kw/m 2 Limiting pile sizes and providing access between piles to restrict the fire size and facilitate effective fire fighting operations Effective fire prevention practices to minimise the risk of fire Protection of the environment from damage in the event of a fire 4. PLANNING RECOMMENDATIONS 4.1 Site Selection It is important for operators to liaise with all relevant authorities and interested parties over proposals for new storage sites. These include: The Metropolitan Fire Brigade (MFB) or The Country Fire Authority (CFA) The appropriate Planning Authority (usually Local Council) The Environment Protection Authority (EPA) WorkSafe Victoria An ideal site for the storage of tyres will not be within the catchment area of any water used for water supply purposes, or where there may be a risk of ground water contamination, should a fire occur The site should also be on flat or gently undulating land, have soil with low levels of salt, have access to an adequate supply of salt free water, be devoid of dense vegetation and trees, have no overhead power lines, and not located in environmentally sensitive areas Priority should be given to locating potential storage sites outside of a Bushfire Management Overlay (BMO) Consideration of siting should be made with reference to prevailing wind conditions, particularly if the proposed site is near residential, health/care facilities, industrial or commercial developments. The proximity of major infrastructure such as roads, railways, navigable waterways, water reservoirs/dams storing potable drinking water, airports, etc., should be considered if dense smoke and toxic products of combustion from a fire could obscure travel routes or adversely impact the health and safety of neighbours. When considering siting with respect to prevailing winds, designers should also consider the impact that a tyre fire could have with regard starting secondary fires in nearby forest/woodland or significant bushland, as a result of fire brands/embers being carried in the prevailing winds from the initial fire location Disused quarries, sandpits, natural crevices, etc, which promote deep pile storage of tyres, should be avoided An impervious layer should also be applied to sites with pervious soil. 4.2 Tyre Pile Size and Separation Distances March 2014 Version 5 Page 2
3 4.2.1 Storage pile sizes should be minimised to restrict the available fuel in the event of a fire Long and narrow tyre piles should be employed in preference to large square piles. Maximum pile dimensions of 20m long x 6m wide x 3m high is recommended The separation distances provided by aisles between individual piles should be designed to inhibit fire spread due to radiant heat and/or direct flame contact during adverse windy conditions. Adequate aisle dimensions are critical for safe fire fighter access during the deployment of hose streams for exposure protection and where possible fire extinguishment, and for the operation of excavation equipment. A minimum separation distance of 20m between piles is recommended, but is not guaranteed to prevent fire spread Storage pile heights should be determined by the stability of the pile, both for normal storage conditions and in the event of a fire, and must not exceed 3m Separation distance of the storage piles to buildings will depend on the building construction. For buildings without appropriate fire resistant construction, this distance should not be less than 20m to allow for fire fighter access and to help prevent fire spread to adjacent buildings. This distance could be reduced on a case by case basis, as part of a fire risk assessment, if the building is constructed of appropriate fire resistance levels Separation distance to boundaries facing public roads should be not less than 6m and not less than 20m to the far boundary of the public road. Separation distance between the edge of storage piles to other boundaries should be no less than 20m. Where in a BPA however, this separation distance may need to be increased as a function of satisfying the required bushfire protection measures of not exceeding a received radiation of 12.5 kw/m Any increases in recommended pile dimensions or decreases in recommended separation distances should be assessed as part of a fire risk assessment as detailed in Part 5 of this guideline. 4.3 Ignition Source Control It is recommended that operators develop and document procedures to control possible ignition sources on site, which should include as a minimum: 4.4 Security A hot work permit procedure for all cutting, welding, grinding type activities Regular inspection and repair of electrical equipment, vehicles, machinery, security fences, etc. Maintain site clear of fine fuels or minimise the accumulation of fine fuels from around stored tyres Restriction of smoking to designated areas No open fires No storage of other flammable or combustible materials, hazardous materials or other easily ignitable material within 30m of any tyre storage. Maintain separation distances to buildings and boundaries The perimeter of the site should be surrounded by a firmly anchored fence or other effective method of security which prevents unauthorised access and is constructed to discourage entry. 4.5 Fire Protection Operators should provide first aid fire fighting equipment for use by staff which may include water and foam fire extinguishers, water and foam hose reels, etc. Research indicates that early extinguishment of a tyre fire may be possible in the first five minutes using water, Class A foam or wetting agents. Staff should be provided with appropriate training on the use, limitations, maintenance, etc., of the March 2014 Version 5 Page 3
4 equipment provided. Refer to Appendix 1, which was developed from the source document at Bibliography Ref Operators should provide a hydrant system compliant with the provisions of AS and maintained in accordance with AS 1851 Section 4. [Bibliography Ref 7.4] For sites that comply with the maximum recommended pile dimensions and minimum separation distances, sufficient firewater for exposure protection and fire extinguishment may be provided by a fire hydrant system designed and installed in accordance with AS and the NCC Volume 1 [Bibliography Ref 7.12]. This should be confirmed by the operator as part of the site fire risk assessment 4.6 Water Supplies The quantities of fire water and foam required to manage the identified fire scenarios for the site, as well as the equipment required to deliver the fire water and foam, should be determined by performing a site fire risk assessment, as detailed in Part 5 of this guide Where town water is unavailable or insufficient, an adequate static water supply of a minimum of 2 x 250,000L tanks located in diagonally opposed positions on site is recommended. Fire pumps for stockpiles in remote locations needs to be considered. The location and capacity of pumps and tanks should be determined as part of a site fire risk assessment, in conjunction with the Fire Services Water provided for fire systems should be potable or Class A recycled water and should be salt free, due to the production of dioxins. [Bibliography Ref 7.5] 4.7 Site Containment of Contaminated Firewater, oil and liquid by-products of combustion An impervious layer should be applied to sites with pervious soil. [Bibliography Ref 7.11] Bund walls or catchment pits should be provided to contain surface run off from the site during fire fighting activities. The containment capacity should be determined as part of the site fire risk assessment and in conjunction with the responding fire service. Note that the required containment capacity is likely to exceed that required by EPA Bund Guideline, Bibliography Ref Emergency response procedures developed by the operator should include the use of excavation equipment such as bulldozers, excavators, etc, to separate unburnt tyres from the burning pile and to build containment berms and oil run off ponds. 4.7 Access for fire brigade appliances Access for emergency vehicles should be provided as detailed in Fire Services Safety Guidelines. [References 7.6 and 7.7] Large sites should have at least two separate and opposing entry points for fire appliance access. 5. Fire Risk Assessment 5.1 The fire risk assessment should be performed in consultation with the relevant fire authority. The fire risk assessment should also be performed in consultation with appropriately qualified and / or experienced consultants 5.2 The fire risk assessment will determine all fire hazards at the site, determine the likelihood that a fire will occur, then determine the consequences of the nominated fire incidents, in terms of life safety, property protection and the environment. 5.3 The fire risk assessment will determine all the resources and equipment required to manage the consequences of the identified fire scenarios. March 2014 Version 5 Page 4
5 5.4 It is expected that, depending on site conditions, equipment available, emergency response procedures, available staff and level of training, etc, the fire risk assessment may require appropriate fire modelling and emission and dispersion modelling to determine possible off site extents of toxic products of combustion. 6. Emergency Preparedness 6.1 Emergency Plan Operators should develop and document an emergency plan which includes all the matters contained in Appendix 2, which has been developed with reference to Bibliography Ref 7.8. The emergency plan should be prepared in consultation with the responding fire service It is recommended that operators develop and document a tactical fire plan for the site that includes: Location of fire hydrants, boosters, fire service tapping(s), fire pumps, static water tanks, etc. Location of all first aid fire fighting equipment, including the location and quantity of stocks of Class A and Class B foam concentrate held Fire fighting actions appropriate to the site Control of fire fighting run off Location of drains, isolation valves, etc Location of access points to the site Location of hazardous materials or dangerous goods stored on site Deployment procedures for excavating equipment, operators, etc. 6.2 Emergency Procedures Emergency procedures should be developed to cover all foreseeable emergencies for the site The emergency procedures should include, as a minimum: The means of raising the alarm Contact details of the emergency services, the EPA, etc. Actions to be taken by employees in the event of an emergency Deployment procedures for excavating equipment, operators, etc. The operator s expectation of actions by the Fire Services Emergency response procedures developed by the operator should include the use of excavation equipment such as bulldozers, excavators, etc, to separate unburnt tyres from the burning pile and to build containment berms and oil run off ponds. 6.3 Emergency Equipment The operator should determine equipment required to contain and manage emergency incidents. For outdoor tyre storage sites this would include equipment such as bulldozers, excavators, tracked loaders, etc., which are required to separate unburnt tyres from the burning pile, and to build containment berms and oil run off ponds. Guidance is provided in Bibliography Ref For equipment that is not always available on site, appropriate arrangements should be in place with equipment suppliers and equipment operators, with deployment procedures developed Operators of excavation equipment should be trained in the use of Self Contained Breathing Apparatus (SCBA), and operators should ensure that sufficient SCBA equipment is available and maintained at all times. Fire Services personnel will not operate on-site excavation equipment, or provide PPE for site equipment operators All staff, including equipment providers and operators, should be appropriately trained in the site emergency plan and emergency response procedures. March 2014 Version 5 Page 5
6 7. Bibliography Reference has been made to the following documents in preparation of this guideline: 7.1 Draft Fire Services Guideline Indoor Storage of New or Used Tyres Special Report: Scrap and Shredded Tire Fires, US Fire Administration/Technical Report Series, USFA-TR-093/December FM Global Property Loss Data Sheet 8-3, Rubber Tire Storage, January AS Fire Hydrant Systems System Design, Installation and Commissioning 7.5 Fire Safety for Tyre Sites, Home Office/The Scottish Office, CFA Guidelines for Subdivision Planning, available at MFB Guideline GL-13, Hardstand and Emergency Vehicle Access for Fighting Appliances, 12 August 2008, and MFB Guideline GL-27, Planning Guidelines for Emergency Vehicle Access and Minimum Water Supplies within the Metropolitan Fire District, 14 April 2009 (available at Safety/Workplace/Fire-Safety-Guidelines.html) 7.8 Dangerous Goods Act 1985, Code of Practice for the Storage and Handling of Dangerous Goods, 2013, WorkSafe Victoria 7.9 GL 013, General Guidelines for the Outdoor Storage of Used Tyres, Amendment A, 28 December 2005, South Australian Fire Services 7.10 Policy No 2, Guidelines for Bulk Storage of Rubber Tyres, Version 1.01, 21 April 2008, Structural Fire Safety Unit, NSW Fire Brigades 7.11 Bund Guideline, EPA Publication Number 347, December 1992 (available at National Construction Code Series, Volume 1, Building Code of Australia, Class 2 to Class 9 Buildings March 2014 Version 5 Page 6
7 Appendix 1 TYRE PRODUCT COMBUSTION STAGES CHRONOLOGY, from Bibliography Ref 7.2 Stages of Tyre Combustion Ignition/Propagation Stage Time 0 to 5 minutes 15 to 30 minutes Compression Stage 30 to 60 minutes Equilibrium/Pyrolysis and Smouldering Stages 60 minutes and beyond Whole Tyre Fire Progress Active tyre burning of individual tyres but has not extended to the entire pile. Once the fire extends to the pile, the flame spread is two square feet every five minutes The top layers of the tyres will collapse on themselves. The visible flaming is reduced. The fire then is seated deep in the pile. Fuel consumption and heat production equalizes. Combustion is efficiently producing sufficient heat to consume most combustion products. Downward pressure of the encompassing pile causes the run-off oil flow to increase. Shredded Tyres Tyre shreds are readily ignited and involve the entire pile quickly. Fire spreads along the surface of the pile very quickly. Burns like coal pile with hot coal bed in center and a clay-like ash crust on top of pile. Clay-like ash crust protects burning core from water stream penetration. Action Early extinguishment with water, class A foam or wetting agents may be possible. Separate unburned tyre/product from the burning pile, downwind first Focus efforts on separation; build containment berms and oil run-off collection ponds. Contain fire spread. Contain run-off oil. Option 1 using the excavator separate burning debris into manageable piles and extinguish with fog streams. Option 2 allow tyre/product fire to burn until the pile can be buried. March 2014 Version 5 Page 7
8 Appendix 2 Emergency Plan Content [Bibliography Ref 7.8] The Emergency Plan should include the following: 1 Name, location, postal address and nature of operations 2 Detailed map of the facility and surrounding area detail 3 Inventory of stored materials 4 Min & Max number of persons expected at the facility 5 Infrastructure likely to be affected by an incident and details of possible off site impacts on neighbours, including residential, commercial and industrial premises 6 Emergency Planning assumptions 7 Description of measures to control the consequences of each hazard and major incident 8 Details of emergency contact personnel 9 Allocation of personnel for implementing the plan 10 Arrangements for mutual aid between adjacent facilities 11 Procedures for early warning to the emergency services of an incident 12 Details of on-site and off-site warning systems 13 Contact details for emergency services 14 Details of on-site communication systems 15 Details of emergency resources on site 16 Arrangement for obtaining additional external resources 17 Procedures for safe evacuation and muster of personnel 18 Details of control points and procedures for essential services 19 Procedures for containment of any incident 20 Procedures for decontamination following an incident March 2014 Version 5 Page 8
FLAMMABLE LIQUIDS COMPLIANCE NOTE
Issued by: Heather Rice Page: 1 of 7 COMPLIANCE NOTE INTRODUCTION This document provides additional guidance to support the Arrangement on Flammable Liquids (Ref No. CYC/HS/A27) CONTENTS Section Topic
ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR 1910.252 WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600
OSHA REGULATION: 9 CFR 90.5 WELDING, CUTTING, AND BRAZING ( HOT WORK ) A. POLICY. This procedure follows requirements set forth in 9 CFR 90.5.. This policy applies to all Hot Work operations being done
Pollution Incident Response Management Plan
Pollution Incident Response Management Plan POLLUTION INCIDENT RESPONSE MANAGEMENT PLAN 1. Introduction This Pollution Incident Response Management Plan (PIRMP) has been prepared to describe the processes
TYPICAL FIRE SAFETY INSPECTION VIOLATIONS
TYPICAL FIRE SAFETY INSPECTION VIOLATIONS The following is a list of typical violations often found by inspectors and a generic solution. You can use this list to improve the safety of your facility, to
Pollution Incident Response Plan
Pollution Incident Response Plan Introduction Schmidt Quarries is committed to ensuring all aspects of our quarrying activities comply with the environmental legislative requirements in NSW. This Pollution
STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders
STORE HAZARDOUS SUBSTANCES SAFELY Suitable containers incompatibles gas cylinders Oxy-Acetylene welding flammable substances 35 36 STORE HAZARDOUS SUBSTANCES SAFELY STORE HAZARDOUS SUBSTANCES SAFELY Storing
Construction Management Statement. Residential development at Bywell House, St Mary s Hill, Ascot
Construction Management Statement Residential development at Bywell House, St Mary s Hill, Ascot Parking of Vehicles of Site Personnel, Operatives and Visitors Site staff, visitors to the development and
Based on the initial size-up and any information available, Command will formulate an action plan to deal with the situation.
Hazardous Materials Response Clear Creek Fire Authority This plan provides a basic philosophy and strategic plan for hazardous materials situations. All Clear Creek Fire policies and procedures, unless
An inventory of hazardous materials used in your workplace will prove useful.
Introduction Fire Protection is an organized approach designed to prevent fires. In the event of a fire, a fire protection program will help prevent or minimize personal injuries, losses, and harm to the
FIREFIGHTER SAFETY. Stay safe during substation fires
FIREFIGHTER SAFETY Stay safe during substation fires FIREFIGHTERS AND SUBSTATIONS Electrical substations reduce the high voltages used to move electricity over long distances to the lower voltages that
INFORMATION BULLETIN BUSINESS FLOOD PLANNING AND MITIGATION GUIDE ACE GLOBAL RISK ENGINEERING. Flood risk assessment. Introduction
ACE GLOBAL RISK ENGINEERING INFORMATION BULLETIN BUSINESS FLOOD PLANNING AND MITIGATION GUIDE Introduction The most common cause of flooding is due to established water storage areas (natural and man-made)
UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS
Fire Safety Technical Guide UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS 1.0. BACKGROUND 1.1. The Regulatory Reform (Fire Safety) Order (known Fire Safety Order) applies to England and Wales (Northern
Safe Operating Procedure
Safe Operating Procedure (Revised 07/09) HOT WORK PERMIT OPERATIONS (For assistance, please contact EHS at (402) 472-4925, or visit our web site at http://ehs.unl.edu/) Authority In recognition of the
Chapter 5.8.3. Fire safety 5.8.3
Chapter 5.8.3 5.8.3 TABLE OF CONTENTS INTRODUCTION.................................................................... 1 PURPOSE OF THIS SUB-CHAPTER......................................................
OREGON FIRE CODE Interpretations and Technical Advisories
OREGON FIRE CODE Interpretations and Technical Advisories A collaborative service by local and state fire professionals, along with our stakeholders and customers, to provide consistent and concise application
ANNEX 2 Emergency / Pollution Incident Response Plan
ANNEX 2 Emergency / Pollution Incident Response Plan Volume 5 of 5 Appendix 21.1 Annex 2 EPIRP Page 1 of 9 1 WIND FARM CONSTRUCTION ENVIRONMENTAL EMERGENCY / POLLUTION RESPONSE PLAN... 3 1.1 Policy...
Hazardous Waste Determination and Management Plan
Hazardous Waste Determination and Management Plan Prepared By: Triumvirate Environmental Developed: November 2014 Updated: Program Approval Associate Vice President of Public Safety & Administrative Services
The following definitions apply with regard to requirements specified in this document:
GUIDELINES FOR INSTALLATION OF TEMPORARY AND PERMANENT ABOVEGROUND DIESEL FUEL TANKS FOR EMERGENCY AND STANDBY POWER SYSTEMS LOCATED OUTSIDE OF BUILDINGS For Use by Unidocs Member Agencies or where approved
MAGB HEALTH, SAFETY AND ENVIRONMENT GROUP POLLUTION INCIDENT RESPONSE PLAN
MAGB HEALTH, SAFETY AND ENVIRONMENT GROUP POLLUTION INCIDENT RESPONSE PLAN SCOPE: This guidance sets out best practice for producing a Pollution Incident Response Plan to deal with an environmental incident
SAFETY MANAGEMENT SYSTEM FOR MAJOR HAZARD FACILITIES - BOOKLET 3: Part 7.17
EMERGENCY PLANNING EXTRACTION FROM: SAFETY MANAGEMENT SYSTEM FOR MAJOR HAZARD FACILITIES - BOOKLET 3: Part 7.17 An extraction from: Safety Management System for Major Hazard page 1 of 14 7.17 Emergency
Fire Safety Risk Assessment Checklist for Residential Care Premises
Checklist for Residential Care Premises Name of Premises: Address of Premises: Name of Responsible Person: What area / location does the assessment cover? Does the assessment cover the whole site YES or
Service Standard 6.1.5. Live Fire Training
Service Standard 6.1.5 Live Fire Training Date of Issue 19 August 2013 Version Number 1.0 1. Purpose 1.1 The ongoing training of members is the cornerstone of good fire suppression in today s world. However,
WASTE Application Form - Dublin Waste to Energy SECTION J ACCIDENT PREVENTION & EMERGENCY RESPONSE
SECTION J ACCIDENT PREVENTION & EMERGENCY RESPONSE Describe the existing or proposed measures, including emergency procedures, to minimise the impact on the environment of an accidental emission or spillage.
Compressed Gas Cylinder Program
Department of Environmental Health & Safety Procedures Compressed Gas Cylinder Program March 2010 Compressed Gas Cylinder Program Page 1 of 8 Table of Contents I. Introduction II. III. IV. Policy Scope
Application & Customer Site Management Plan to Use Recycled Water from a Standpipe
Application & Customer Site Management Plan to Use Recycled Water from a Standpipe This application forms part of Western Waters Recycled Water Temporary Supply Agreement (TSA) as a Customer Site Management
BEHANS LAND RESTORATION LIMITED RESTORATION OF FORMER QUARRY BLACKHALL, CO. KILDARE OUTLINE CONTINGENCY PLAN MAY 2008
BEHANS LAND RESTORATION LIMITED RESTORATION OF FORMER QUARRY BLACKHALL, CO. KILDARE OUTLINE CONTINGENCY PLAN MAY 2008 JBA Prepared by : John Barnett and Associates / SLR Consulting 7 Dundrum Business Park
1.0 Purpose... 4. 2.0 Definitions...4. 3.0 Hot Work Operations. 5
HOT WORK PROGRAM Introduction The University of Kentucky recognizes a potential for fire from hot work operations. For that reason this program should be implemented in all departments at the University
Outdoor Storage of Raw Materials SC-33
Objectives Cover Contain Educate Reduce/Minimize Description Raw materials, by-products, finished products, containers, and material storage areas exposed to rain and/or runoff can pollute stormwater.
Warehouse Checklist. Warehouse Construction
PAGE 1 Warehouse Checklist Recent NFPA statistics estimate that in 1998 approximately 36,000 fires occurred in structures used for storage, accounting for $687mm of damage (over 10% of total fire damage
EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM
EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29CFR1910.36-29CFR1910.38-29CFR1910.157-29CFR1910.165 NFPA-10 BASIS: The OSHA Emergency Action Planning and the
HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids
Flammable Liquids Storage Introduction This guideline is designed to help you store flammable liquids safely. It is based on the requirements of the Ontario Fire Code, Part 4, and of the Regulations for
LIQUID WASTE TREATMENT FACILITY MENDIS ROAD, HUDSON CREEK DRAFT GUIDELINES FOR A PUBLIC ENVIRONMENTAL REPORT
LIQUID WASTE TREATMENT FACILITY MENDIS ROAD, HUDSON CREEK DRAFT GUIDELINES FOR A PUBLIC ENVIRONMENTAL REPORT Introduction The purpose of this Public Environmental Report (PER) is to provide the Government
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011, Updated March 2012 COLORADO SPRINGS FIRE DEPARTMENT Division of the Fire Marshal If you have any questions or
WHS LEGISLATIVE COMPLIANCE GUIDELINES
WHS LEGISLATIVE COMPLIANCE GUIDELINES CONTENTS 1 Introduction... 2 2 Scope... 2 3 Responsibilities... 2 3.1 Manager WHS Unit... 2 3.2 Management of Faculties, Divisions and Research Institutes... 2 4 Maintaining
Liberty Mutual Insurance RISK ENGINEERING PROCEDURE. REP 07 Incident Planning For external use
Liberty Mutual Insurance RISK ENGINEERING PROCEDURE REP 07 Incident Planning For external use Risk Engineering Procedure Incident Planning CONTENTS Page PURPOSE... 3 BACKGROUND... 4 INCIDENT PLANNING PREPARATION...
Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal
Ontario Fire Code SECTION 5.13 DIP TANKS Illustrated Commentary Office of the Ontario Fire Marshal Dip Tanks Illustrated Commentary 1 5.13.1. Location 5.13.1.1. Dip tank operations involving flammable
Decree of the Ministry of the Environment. on fire safety of garages
E4 THE NATIONAL BUILDING CODE OF FINLAND Fire safety of garages Guidelines 2005 Decree of the Ministry of the Environment on fire safety of garages Adopted in Helsinki, 22 March 2005 Pursuant to the Decision
Temporary Batch Plants
Categories EC SE TC WE NS WM Erosion Control Sediment Control Tracking Control Wind Erosion Control Non-Stormwater Management Control Waste Management and Materials Pollution Control Legend: Primary Category
Ingredion ANZ Pty Ltd
Ingredion ANZ Pty Ltd 170 Epping Road, Lane Cove, NSW 2066 EPL: 518 Page 1 of 8 1. Purpose and Background POLLUTION INCIDENT RESPONSE The purpose of this Pollution Incident Response Management Plan (PIRMP)
Safety and Health Office WORKPLACE SAFETY CHECKLIST
Location: Date: Inspected by: Safety and Health Office WORKPLACE SAFETY CHECKLIST WORK ENVIRONMENT Ventilation Removal of fumes and dust Temperature and humidity control Noise levels Vibration Lighting
Course of Construction Questionnaire
Course of Construction Questionnaire CLIENT DETAILS Broker: Contact: Insured s name: Policy number: Address undergoing works: Insured s contact phone number: 1) Name and address of Contractor: 2) Contractor
FIRE SAFETY GUIDANCE NOTE Regulatory Reform (Fire Safety) Order 2005
FIRE SAFETY GUIDANCE NOTE Regulatory Reform (Fire Safety) Order 2005 Number: GN66 This Guidance Note provides advice on the requirements of the Regulatory Reform (Fire Safety) Order 2005 and how to complete
Flammable Liquids Storage
A Health and Safety Guideline for Your Workplace Flammable Liquids Storage Introduction This guideline is designed to help you store flammable liquids safely. It is based on the requirements of the Ontario
9/15/2011. Presented by: Jason Reason, CIH, CSP, CHMM Senior Industrial Hygienist Indiana Occupational Safety and Health Administration
OSHA Combustible Dust Inspections Presented by: Jason Reason, CIH, CSP, CHMM Senior Industrial Hygienist Indiana Occupational Safety and Health Administration Overview Background Information OSHA Combustible
PRODUCT SAFETY DATA SHEET According to 91/155 EC 1. IDENTIFICATION OF THE SUBSTANCE / PREPARATION AND OF THE COMPANY / UNDERTAKING
G.W.B.PRODUCT LTD, 276 YORK WAY, LONDON N79PH TEL:020 7619 1650 FAX:020 7609 9196 EMAIL:[email protected] www.gwbproducts.co.uk -1-1. IDENTIFICATION OF THE SUBSTANCE / PREPARATION AND OF THE COMPANY /
Fire Pump Plan Review March 2010
Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:
FIRE SAFETY FOR OFFICE WORKERS
FIRE SAFETY FOR OFFICE WORKERS This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation. Featured are: INTRODUCTION: A brief description of the program and the subject
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business
APPENDIX 4. Risk Tables
APPENDIX 4 Tables Preliminary Qualitative Criteria The qualitative risk assessment criteria have been developed to identify key risks to the environment, society, heritage and business reputation. The
FLA S FIRE SAFETY INITIATIVE
Improving Workers Lives Worldwide FLA S FIRE SAFETY INITIATIVE Preventing fires and saving lives by empowering workers and factory managers SCENARIO 1 OCCURS AT FACTORY ABC, WHICH HAS NOT IMPLEMENTED NECESSARY
Civil Engineering Sector Labour-Management Health and Safety Committee
PROCEDURE FOR THE STORAGE AND HANDLING OF FUEL ON CONSTRUCTION SITES Civil Engineering Sector Labour-Management Health and Safety Committee July 2008 PROCEDURE FOR THE STORAGE AND HANDLING OF FUEL ON CONSTRUCTION
HYDROCARBON SPILLS PROCEDURE SIG-ENV-PR003
Page: 1 of 6 PROCEDURE SIG-ENV-PR003 Revision Approved Date Description 1 AV 01/04/99 New EP 2 AV 07/06/00 Revision of EP 3 AV 04/04/03 Revision of EP 4 Stuart Roseby DRAFT 5 Stuart Roseby 25/07/2005 Approved
Emergency planning at a major hazard facility
Guidance Note Emergency planning Advice for operators of major hazard facilities on developing an emergency plan. April 2011 1. Introduction 1 1.1 Features of a successful emergency plan 1 1.2 Key concepts
Planning for Bushfire Risk Mitigation General Code
Planning for Bushfire Risk Mitigation General Code March 2008 Contents 0H1. Introduction 14H1 1H1.1 Purpose... 2H1.2 Aim... 3H2. Principles 17H2 4H2.1 Shared Responsibility... 5H2.2 Prevention, Preparedness,
HOT WORK PERMIT PROGRAM TRAINING. John Braun
HOT WORK PERMIT PROGRAM TRAINING John Braun 1.0 INTRODUCTION 1.2 Purpose The Hot Work Permit Program has been developed for University employees that work on or around hot work activities. This program
STANDARD SITE LICENCE CONDITIONS FOR RESIDENTIAL PARK HOME SITES IN GUILDFORD CARAVAN SITES AND CONTROL OF DEVELOPMENT ACT 1960 (AS AMENDED)
STANDARD SITE LICENCE CONDITIONS FOR RESIDENTIAL PARK HOME SITES IN GUILDFORD CARAVAN SITES AND CONTROL OF DEVELOPMENT ACT 1960 (AS AMENDED) CONDITIONS ATTACHED TO SITE LICENCE NO: (insert ref) (insert
Environmental Management Plan
Environmental Management Plan This environmental management plan outlines Red Bus Services objectives and strategies for protecting the environment. This plan sets out how Red Bus Services intends to comply
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011 COLORADO SPRINGS FIRE DEPARTMENT Division of the Fire Marshal If you have any questions or comments regarding the
Denver Fire Department Idle Pallet Storage Guidelines Per NFPA 13_Chpt 12
Idle wood and plastic pallets introduce a severe fire condition. Stacking idle pallets in piles is the best arrangement of combustibles to promote rapid spread of fire, heat release, and complete combustion.
PREVENTING GROUNDWATER POLLUTION: SECONDARY CONTAINMENT
PREVENTING GROUNDWATER POLLUTION: SECONDARY CONTAINMENT PREVENTING GROUNDWATER POLLUTION IS EVERYONE S JOB! Even if our drinking water comes from rivers, lakes, or reservoirs, we need to be mindful of
CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES
CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES Review the following information pertaining to Construction Fire Safety Planning: B.C. Building Code Sections 8.1 up to and including Subsection 8.2.3 B.C.
Gas Standards and Safety. Guidance Note GAS INSTALLATIONS SUPPLIED FROM BIOGAS FACILITIES - ACCEPTANCE REQUIREMENTS GAS ACT 2000
Gas Standards and Safety Guidance Note January 2015 (GN106) Version 1.0 GAS INSTALLATIONS SUPPLIED FROM BIOGAS FACILITIES - ACCEPTANCE REQUIREMENTS GAS ACT 2000 A guide to assist in the design of biogas
(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations;
(1979) (Rev.1 1990) (Rev.2 1996) (Rev.3 Jan 2012) Safety features.1 Fire protection and extinction.1.1 General Fire protection arrangements and fire extinguishing systems are to be in accordance with the
Safe use of liquefied petroleum gas (LPG) at small commercial and industrial bulk installations
Safe use of liquefied petroleum gas (LPG) at small commercial and industrial bulk installations When the risks are properly identified and managed, LPG can be safely used as a fuel source for many applications.
c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.
Walmart Standards for Suppliers Section 7. Health and Safety 7. Health and Safety Suppliers must provide workers with a safe and healthy work environment. Suppliers must take proactive measures to prevent
Fire Safety In High Rise Building
Fire Safety In High Rise Building CLASSIFICATION OF BUILDINGS AS PER NATIONAL BUILDING CODE 1. GROUPING. Group A - Residential : Lodgings, Dwellings, Dormitories, Flats, Hotels. Group B Group C - Educational
Company Name Chemical Spill Prevention & Clean-up Procedures Program. Last Revised On 00/00/0000
Company Name Chemical Spill Prevention & Clean-up Procedures Program Last Revised On 00/00/0000 PURPOSE The following program will discuss how prevent chemical spills from occurring and setting forth procedures
Name Of Occupancy Date. Yes No Describe
FIRE PREVENTION INSPECTION CHECKLIST For Class A Occupancy (For Assembly Buildings, Bars, Restaurants, Gyms, Churches, Arenas, Theatres or wherever people gather) Name Of Occupancy Date Physical Address
BP WIND ENERGY POLICIES AND PROCEDURES
BP WIND ENERGY POLICIES AND PROCEDURES Document Control Details 1.0 Purpose/Scope 1.1 This procedure provides the minimum requirements to be followed for the storage of flammable or combustible materials
contractors, etc. and establish relationships with lease and rental companies.
The following may serve as a checklist when preparing for a Tropical Storm or Hurricane. Although Tornadoes usually provide little advance warning, locations subject to Tornadoes may apply much of the
Chemical Storage and Spill Response Guidelines
Chemical Storage and Spill Response Guidelines 9TP-SD-066/3.0 Supporting Document Applicable to Transport Projects Delivery Office Quality Management System Status: Approved Version: 3.0 Branch: Business
Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009
Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009 By Carsten Palle, VID Fire-Fill, www.vid.eu Presented at ISTSS
Ethanol Vehicle and Infrastructure Codes and Standards Citations
Ethanol Vehicle and Infrastructure Codes and Standards Citations This document lists codes and standards typically used for U.S. ethanol vehicle and infrastructure projects. To determine which codes and
EACH CLASS of fire A, B, C, or D has a different source. Some
Classes of Fires and Types of Extinguishers EACH CLASS of fire A, B, C, or D has a different source. Some principles apply to putting out all fires. However, certain procedures and products are used only
Flammable Liquids Storage
A Health and Safety Guideline for Your Workplace Flammable Liquids Storage Introduction This guideline is designed to help you store flammable liquids safely. It is based on the requirements of the Ontario
Dip Tanks. RS 1030 (9/13) 2013 Nationwide Mutual Insurance Company Page 1 of 9 All Rights Reserved
This Data Sheet discusses the fire and explosion hazards associated with dip tanks as well as several fire prevention tactics. EPA information is included as an added benefit only. The information from
Caravan Park FIRE SAFETY
Caravan Park FIRE SAFETY PUBLISHED MAY 2012 Contents Foreword 2 Introduction 3 Definitions 5 Background 8 Key stakeholder responsibilities 9 Guideline structure 10 Application of the guideline 12 Alternative
Presented by: Rich Perry Marsh Risk Consulting
Flammable and Combustible Liquids Presented by: Rich Perry Marsh Risk Consulting What s the Big Deal? Flammable and combustible liquids are easily ignited Ignite with explosive force Burn readily and give
Nu G Medical Waste System Technology (Pyrolysis / Thermal Decomposition)
Product Description: Nu G Medical Waste System Technology (Pyrolysis / Thermal Decomposition) The NU G System uses pyrolysis thermal decomposition to treat infectious wastes typically generated in hospitals.
GUIDELINES FOR PROCESSING AND USING REFUSE DERIVED FUEL (RDF) IN CEMENT INDUSTRY
1 GUIDELINES FOR PROCESSING AND USING REFUSE DERIVED FUEL (RDF) IN CEMENT INDUSTRY August, 2012 Government of Pakistan Pakistan Environmental Protection Agency (Ministry of Climate Change) Islamabad 2
Material Safety Data Sheet
1 IDENTIFICATION OF THE SUBSTANCE AND COMPANY a) SUBSTANCE: Natural Gas b) COMPANY: Bord Gáis Éireann PO Box 51 Gasworks Road Cork Telephone: (021) 453 4000 Emergency Telephone: 1850 20 50 50 2 COMPOSITION/INFORMATION
PROCEDURES PREVENTION OF ACCIDENTAL IGNITION
Page No: 1 of 7 6.0 PURPOSE (192.751) All possible precautions shall be exercised to prevent the accidental escape and ignition of gas. Whenever possible, potential sources of ignition should be eliminated
Section 14. Forklift Safety Contents 14.1 Operator Safety
Section 14. Forklift Safety Contents 14.1 Operator Safety... 14-1 14.2 Inspection and Maintenance... 14-2 14.3 Handling the Load... 14-3 14.4 Fueling Liquefied Petroleum (LP) Gas Forklifts... 14-3 14.5
FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST
FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST Date of Inspection: Conducted by: Location: Reviewed by: Date of Review: Comments or additional corrective action taken as a result
FIRE RISK ASSESSMENT
The Regulatory Reform (Fire Safety) Order 2005 FIRE RISK ASSESSMENT Employer or other responsible person Name of Premises Address Post Code Telephone N o Name of Assessor(s) Date of Assessment Date of
Guide to Certification for Retail Hardware Stores
Guide to Certification for Retail Hardware Stores A Guide for the Person in Charge DECEMBER 2011 TECHNICAL GUIDE 2 Table of contents Table of contents... 2 Preface... 3 Purpose of this publication... 4
HOT WORK PERMIT PROCEDURES
COLUMBIA UNIVERSITY ENVIRONMENTAL HEALTH & SAFETY HOT WORK PERMIT PROCEDURES COLUMBIA UNIVERSITY MEDICAL CENTER February 2010 1 TABLE OF CONTENTS A. PURPOSE 3 B. SCOPE 3 C. POLICIES AND PROCEDURES 3-4
Propane Gas Underground Systems: Residential Infrastructure Requirements and Energy Benefits
Propane Gas Underground Systems: Residential Infrastructure Requirements and Energy Benefits AIA Best Practices The Propane Education & Research Council and HanleyWood are registered providers with the
Errata NFPA 1. Fire Code. 2015 Edition
Errata NFPA 1 Fire Code 2015 Edition Reference: 2.2, Table 6.1.14.4.1(a) and (b), 13.3.1.6, 13.7.2.13.2.1, 14.11.3.3, 18.5.2, 18.5.3, 20.1.2, 20.1.5.12, 25.1.1, 25.3, 25.4, A.3.3.164.2, and A.13.3.2.9.1
FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes
FLAMMABLE AND COMBUSTIBLE LIQUIDS OSHA Changes Introduction This module covers the two primary hazards associated with flammable and combustible liquids: explosion and fire. In order to prevent these hazards,
Requirements for Hydrogen Storage and Use
Requirements for Hydrogen Storage and Use I. INTRODUCTION Fire and Life-Safety Group (FLS) The following is a summary of the fire and building code requirements for the storage and use of hydrogen. These
WORKING IN CONFINED SPACES GUIDELINES
WORKING IN CONFINED SPACES GUIDELINES Contents 1 Introduction... 2 2 Scope... 2 3 Definitions... 2 4 Responsibilities... 3 4.1 Permit Authoriser... 3 4.2 Permit Receiver... 3 4.3 Responsible UOW Officer...
FLAMMABLE AND COMBUSTIBLE LIQUIDS
GAP.8.1.0 A Publication of Global Asset Protection Services LLC FLAMMABLE AND COMBUSTIBLE LIQUIDS INTRODUCTION National Fire Protection Association (NFPA) documents describe a level of fire protection
FIRE PREVENTION PLAN
FIRE PREVENTION PLAN 1 FIRE PREVENTION PLAN OSHA s Fire Prevention Plan regulation, found at 29 CFR 1910.38(b) and 29 CFR 1926.24, requires Northern Clearing, Inc. to have a written fire prevention plan
General Fire Code Requirements Within Commercial Tenant Spaces
FIRE DEPARTMENT in cooperation with Scope: General Fire Code Requirements Within Commercial Tenant Spaces This handout is designed to assist owners, architects, contractors and others in understanding
Suffolk County Department of Health Services. Division of Environmental Quality
Suffolk County Department of Health Services Division of Environmental Quality Guidelines For the Construction of Storage Areas for Portable Containers ~~~~ Clare B. Bradley, M.D., M.P.H. Suffolk County
Annual Storm Water Pollution Prevention Plan and Spill Prevention, Control and Countermeasures Plan Compliance Inspection
Annual Storm Water Pollution Prevention Plan and Spill Prevention, Control and Countermeasures Plan Compliance Inspection September 22, 2014 Prepared By: Facilities Management Environmental Resources University
LANCASTER UNIVERSITY. MANUAL OF SAFETY Section 29 POLICY ON FIRE RISK ASSESSMENTS
LANCASTER UNIVERSITY MANUAL OF SAFETY Section 29 POLICY ON FIRE RISK ASSESSMENTS 1 Introduction 1.1 The Fire Precautions (Workplace) Regulations, require the University to carry out fire risk assessments
GUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS
GUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS 1.0 PURPOSE 1.1 To provide an overview of fire extinguisher use
EAST LINDSEY DISTRICT COUNCIL ~ RESIDENTIAL CARAVAN SITES CONDITIONS OF SITE LICENCE
Residential Site Licence Conditions of Licence February 2014 EAST LINDSEY DISTRICT COUNCIL ~ RESIDENTIAL CARAVAN SITES Index of conditions CONDITIONS OF SITE LICENCE 1. Period of use 2. Bases 3. Siting