3 Interfacing the AlphaGUARD Radon Monitor with Campbell Scientific's CR1000 Datalogger This application note describes interfacing a CR1000 datalogger with a standard version of the AlphaGUARD Professional Radon Monitor Model P30 (not the overdrive version). The efforts to interface the AlphaGUARD Radon Monitor with the CR1000 Datalogger, and the writing of this application note were accomplished in collaboration with personnel from DRI, the environmental research arm of the Nevada System of Higher Education 1. The AlphaGUARD is manufactured by Saphymo GmbH ( 2. This document is intended as a supplement to the manufacturer s brochure and the manuals titled: User Manual Portable Radon Monitor AlphaGUARD dated 12/98 and AlphaGUARD Data Transfer Specifications version 4.0 dated 7/ Radon Detection Basics Two techniques are available for measuring radon activity; the best technique to use depends on the application. The techniques are integrative, passive radon sampling and continuous active radon sampling. Integrative, passive radon sampling does not require electrical power, whereas continuous active radon sampling does. Examples of sensors that can measure radon levels include alpha track detectors, activated charcoal adsorption devices, and the AlphaGUARD monitor. Alpha track detectors are integrative, passive radon sampling devices that do not require ac power. They contain a thin piece of plastic or film mounted in the detector. Radon flows into the detector through a filtered opening. As the radon inside the detector decays, the emitted alpha particles hit the film forming tracks on the film. The tracks are counted to determine radon concentration. These detectors are not very effective in measuring high concentrations of radon [Spe04]. Activated charcoal devices are passive sensors that do not require ac power. They consist of a canister that holds granular-activated carbon (i.e., activated charcoal). The charcoal absorbs radon that enters the canister via a screened opening. After a determined exposure period, the canister is sealed and the charcoal is analyzed using a HPGe gamma ray detector [Ger04]. Activated charcoal devices are preferable for short-term measurements (i.e., 1 to 7 days). They are not practical for locations with high humidity because the charcoal can become saturated [Ger04]. The AlphaGUARD radon monitor is a continuous active radon sampling sensor. It has an ionization chamber and uses an alpha spectroscopy to detect radon. The two common isotopes of radon (i.e., 222Rn and 220Rn) are identified through their respective energies from the alpha decays [Swa04]. The signal generated from the alpha detection is converted to a digital output. This output can be read by the AlphaGUARD, dataloggers, or a PC. Ideal applications for the AlphaGUARD include radon exhalation, radon soil-gas, indoor, outdoor, in mining environments and in-water storage radon measurements. 1 DRI Project: Ambient Radon Monitoring in Amargosa Valley, Nevada DRI Personnel: Greg McMurdy ([email protected]), Jeff Tappen ([email protected]) 2 AlphaGUARD Professional Radon Monitor Model P30 is manufactured by Saphymo GmbH, Heerstraße 149, D-60488, Frankfort Germany, In the U.S., the AlphaGUARD is available from Rad Elec, Inc., 5716-A Industry Lane, Frederick, Maryland 21704, phone (800) , (301) ; fax (301) Approximate price is 6575 EUR or US $9,886. Copyright 2009 Campbell Scientifi c, Inc W N., Logan, UT (435) App. Note: 2MI-U
4 Interfacing the AlphaGUARD with the CR AlphaGUARD Sensor Description The AlphaGUARD is designed for long-term monitoring of radon gas concentration. It has a linear response from 2 to 2,000,000Bq/m 3 (0.05 to 50,000 pci/l). See the next section and the AlphaGUARD brochure for more specifications. The AlphaGUARD measures radon concentration using 3D alpha spectroscopy. There is a lag in the signal due to the time required for radon to diffuse into the ionization chamber. When exposed to a step change in radon concentration, the AlphaGUARD will reach 30% of the new value after 10 minutes, 70% after 20 minutes and 90% after 30 minutes. The AlphaGUARD has an internal battery that will run it for approximately 10 days. The unit can be AC powered with an AC to 12 Vdc wall charger from Radio Shack or CSI pn Alternatively the AlphaGUARD may be DC powered using CSI pn CSI pn14291 has a mating barrel connector on one end and red and black stripped and tinned leads to be connected to 12 Vdc and ground on the other end. 3. Specifications Figure 1. Front view of the AlphaGUARD Professional Radon Monitor Model P30 (standard version). The best source of specifications on the AlphaGUARD is the manufacturer s brochure which may be found at A few specifications are listed below for your convenience. Campbell Scientific recommends you refer to the manufacturer's brochure to verify critical specifications. Measurement Range: Operating temperature: Operating pressure: Operating RH: Operating voltage: Current drain: 2 to 2,000,000 Bq/m 3 (0.05 to 50,000 pc/liter) +14 to +122 F (-10 to +50 C) 700 to 1100 mbar 0 to 99% RH 12 Vdc (or 110 Vac with converter to 12 Vdc) unknown (unit will run on internal battery for 10 days) 2 Copyright 2009 Campbell Scientifi c, Inc. App. Note: 2MI-U 815 W N., Logan, UT (435)
5 4. Installation Interfacing the AlphaGUARD with the CR1000 The AlphaGUARD must be switched on manually (On/Off switch). Using the Menu, Change, and Accept buttons and the display, set the AlphaGUARD measuring cycle to 10 minutes and the baud rate to 9600 baud. The datalogger will time stamp the data but if it is important that the display indicate the correct time, set the AlphaGUARD clock using the serial interface software DataEXPERT provided with the unit. The AlphaGUARD user manual indicates the automatic background correction of the AlphaGUARD can only be executed at the beginning of a measuring series. Therefore with measurements lasting longer than six months, the set up of a new measuring series should be manually enforced, by turning the power switch OFF and then on again after every half year. Setting the system clock with DataEXPERT will also initiate a new measuring series. 5. Wiring The following wiring diagram is built for the program in Section 6 which is where the CR1000 s COM1 port (C1 & C2) will request and capture data from AlphaGUARD s RS-232 port. The color scheme indicated in the last column is specific to the two foot long DTE cable which is one of two cables that come in Campbell Scientific s model SC110 (or pn16721). AlphaGUARD Function TABLE 1: AlphaGUARD to CR1000 Wiring AlphaGUARD 9-pin CR1000 Terminal CR1000 Function CSI SC110 DTE color TxD 2 C2 RxD White RxD 3 C1 TxD Brown GND 5 GND GND Yellow GND Shell GND Clear Figure 2. Above shows the AlphaGUARD connected to a CR1000 datalogger. Copyright 2009 Campbell Scientifi c, Inc W N., Logan, UT (435) App. Note: 2MI-U
6 Interfacing the AlphaGUARD with the CR Example Program for the CR1000 This CR1000 program is for the standard version of the AlphaGUARD, not the overdrive version. It was tested on an AlphaGUARD with serial number 1635 EF. 'CR1000 Series Datalogger ' ' Program for Alphaguard Radon detector Public fpval Public sign Public mantissa Public exp1 Public exponent Public Radon,RadonErr,AirTemp,RelHum,BaroPress Public Akkustd,KBeqstd,Totalstd Public ASerial as string * 6,Aversion as string * 4 Public PTemp, batt_volt ' Public HexV(80) as String *2 ': for debugging DataTable (Test,1,-1) DataInterval (0,15,Sec,10) Minimum (1,batt_volt,FP2,0,False) Sample (1,PTemp,FP2) EndTable Public Str3 As String * 80 Public CurrDate as String * 12 Public DataDate as String * 12 Public Atemp, Arh Public start As Long,i, rtnbyte(2), array(129) As Long Alias array(8) = year Alias array(9) = month Alias array(10)=days Alias array(11)=hrs Alias array(12)=minutes Alias array(13)=seconds Alias array(14)=mesyear Alias array(15)=mesmonth Alias array(16)=mesday Alias array(17)=meshr Alias array(18)=mesmin Alias array(19)=messec Alias array(20)=notused Alias array(28)=cycletime Alias array(35)=dataqa Alias array(36)=sysqa 4 Copyright 2009 Campbell Scientifi c, Inc. App. Note: 2MI-U 815 W N., Logan, UT (435)
7 Interfacing the AlphaGUARD with the CR1000 Function FLP2 (mant,expo) sign = IIF(expo AND &H80,1.0,-1.0) mantissa = mant/256.0 exp1 = (expo AND &H7F) - 64 exponent = PWR(2,exp1) FLP2 = (sign * mantissa) * exponent EndFunction Function FLP4 (mant1,mant2,mant3,expo) sign = IIF(expo AND &H80,1.0,-1.0) mantissa = (mant3 + ((mant2*256)) + ((mant1*65536)))/ exp1 = (expo AND &H7F) - 64 exponent = PWR(2,exp1) FLP4 = (sign * mantissa) * exponent EndFunction BeginProg 'Open COM1 at 9600 baud SerialOpen (Com1,9600,3,10,1000) ' format for binary, 8-bit, no parity. Scan (10,Sec,0,0) PanelTemp (PTemp,250) Battery (Batt_volt) If TimeIntoInterval (0,1,Min) start = 1 endif If start Then ' Output string to query Alphaguard SerialFlush(com1) ' Clean out buffers Str3 = CHR(2) SerialOutBlock (Com1,Str3,1) Delay (0,100,mSec) str3= CHR(3) + CHR(83) + CHR(3) + CHR(91) SerialOutBlock (Com1,Str3,4) ' Wait for return of data from Alphaguard Delay (0,4,Sec) i=1 rtnbyte(2)=serialinchk(com1) While rtnbyte(2) i=i+1 SerialInBlock(Com1,array(1),1) MoveBytes (array(i),3,array(1),0,1) Copyright 2009 Campbell Scientifi c, Inc W N., Logan, UT (435) App. Note: 2MI-U
8 Interfacing the AlphaGUARD with the CR1000 ' following line useful for debugging ' hexv(i) = Hex(array(i)) rtnbyte(2)=serialinchk(com1) Wend start=0 CurrDate = right("0" & Hex(year),2) & right("0" & Hex(month),2) & right("0" & Hex(days),2) CurrDate = CurrDate & right("0" & Hex(hrs),2) & right("0" & Hex(minutes),2) & right("0" & Hex(seconds),2) DataDate = right("0" & Hex(mesyear),2) & right("0" & Hex(mesmonth),2) & right("0" & Hex(mesday),2) DataDate = DataDate & right("0" & Hex(meshr),2) & right("0" & Hex(mesmin),2) & right("0" & Hex(messec),2) Radon = FLP2(array(32),array(31)) RadonErr = FLP2(array(34),array(33)) AirTemp = FLP2(array(40),array(39)) RelHum = FLP2(array(46),array(45)) BaroPress = FLP4(array(42),array(43),array(44),array(41)) Akkustd = FLP4(array(48),array(49),array(50),array(47)) KBeqstd = FLP4(array(52),array(53),array(54),array(51)) Totalstd = FLP4(array(56),array(57),array(58),array(55)) ASerial = CHR(array(60)) & CHR(array(61)) & CHR(array(62)) & CHR(array(63)) & CHR(array(64)) & CHR(array(65)) AVersion = CHR(array(66)) & CHR(array(67)) & CHR(array(68)) & CHR(array(69)) EndIf NextScan EndProg 7. Maintenance and Troubleshooting 8. References See AlphaGUARD User Manual. [Ger04] Gervino, G., Bonetti, R., Cigolini, C., Marino, C., Prati, P., Pruiti, L. (2004). Environmental radon monitoring: comparing drawbacks and performances of charcoal canisters, alpha-track and E-PERM detectors. Nuclear Instruments and Methods in Physics Research A, Vol. 518, pp [Spe04] [Swa04] Speelman, W., (2004). Master of Science full thesis, Department of Physics, University of the Western Cape, Australia. Modeling and Measurement Of Radon Diffusion Through Soil for Application On Mine Tailings Dams, pp Swakon, J., Kozak, K., Paszkowski, M., Gradzinski, R., Łoskiewicz, J., Mazur, J., Janik, M., Bogacz, J., Horwacik, T., Olko, P. (2004). Radon concentration in soil gas around local disjunctive tectonic zones in the Krakow area. Journal of Environmental Radioactivity, Vol. 78, Issue 2, pp Copyright 2009 Campbell Scientifi c, Inc. App. Note: 2MI-U 815 W N., Logan, UT (435)
ViZion Installation Guide
ViZion Installation Guide v2.0 1 ViZion Installation Guide Table of Contents Inventory Hardware Setup Understanding Synchronization Cable Begin by taking an inventory of the required equipment DR Unit
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
RS-232 COMMUNICATIONS
Technical Note D64 0815 RS-232 COMMUNICATIONS RS-232 is an Electronics Industries Association (EIA) standard designed to aid in connecting equipment together for serial communications. The standard specifies
LLAC4 Four-Channel, Low-Level AC Conversion Module Revision: 3/12
LLAC4 Four-Channel, Low-Level AC Conversion Module Revision: 3/12 Copyright 2004-2012 Campbell Scientific, Inc. Warranty PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific,
Ramon 2.2 Radon-Monitor
Ramon 2.2 Radon-Monitor Applications Measurement Modes - Technology - Quality 1 1) Application of the Ramon 2.2: The Ramon2.2 Radon monitor is a unique device and it can be best described as an automatic,
APPLICATION NOTE. EKO MS-710 and MS-712 Broadband Infrared Spectroradiometers (WISER Series) with CR3000 Datalogger 4/14. App.
App. Note Code: 2RA-K APPLICATION NOTE EKO MS-710 and MS-712 Broadband Infrared Spectroradiometers (WISER Series) with CR3000 Datalogger 4/14 Copyright 2013-2014 Campbell Scientific, Inc. Table of Contents
[USING THE NM150 WITH ADULTICIDING] July 13, 2015
Reason Adulticiding 3.5 includes support for the New Mountain NM150 Weather Station. Adulticiding fogger log point details include temperature, wind speed, and wind direction. These can be recorded from
Using a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System
Using a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System ECU DB9 USB 20-060_A.DOC Page 1 of 18 9/15/2009 2009 Precision Airmotive LLC This publication may not be copied
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 1. Introduction Thank you for purchasing this 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter. It is an
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version
PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL
Rev. D PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL 10 BORIGHT AVENUE, KENILWORTH NEW JERSEY 07033 TELEPHONE: 800-524-0273 FAX: 908-686-9317 TABLE OF CONTENTS Page
Model 201 Wiegand Touchpad Reader Installation Guide
Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
TruPower-Portable-500W. Solar Starter kit
TruPower-Portable-500W Solar Starter kit This Solar starter kit is an easy to use solar power supply system that is the complete solution for all your solar power needs. It is a solar generator that converts
WEB log. Device connection plans
WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20151210* Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited,
XP Series Balances Operation Manual
XP Series Balances Operation Manual North and South America: 6542 Fig Street Arvada, Colorado 84 1-8-321-1135 Tel: 33-431-7255 Fax: 33-423-4831 U.K. and Ireland: Denver House, Sovereign Way Trafalgar Business
Wireless Security Camera
Wireless Security Camera Technical Manual 12/14/2001 Table of Contents Page 1.Overview 3 2. Camera Side 4 1.Camera 5 2. Motion Sensor 5 3. PIC 5 4. Transmitter 5 5. Power 6 3. Computer Side 7 1.Receiver
RC2200DK Demonstration Kit User Manual
Demonstration Kit User Manual Table of contents TABLE OF CONTENTS... 1 QUICK INTRODUCTION... 2 INTRODUCTION... 3 DEMONSTRATION BOARD... 4 POWER SUPPLY SECTION... 5 RS-232 INTERFACE... 6 CONNECTORS... 7
Bluetooth to Serial Adapter
Bluetooth to Serial Adapter Third Edition, Oct 2007 Version 3.0 771-BTS1009C3-001 Contents 1.0 Features....P.2 2.0 Package Content....P.2 3.0 Hard Drives Requirement.P.2 4.0 Specifications.P.3 5.0 Pin
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
Knowledge Base Article. Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers
Knowledge Base Article Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers Copyright 2009-2012, ISONAS Security Systems All rights reserved Table of Contents 1: INTRODUCTION...
How to read this guide
How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information
Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English. 1-800- RAIN BIRD (800-724-6247) or visit www.rainbird.
Rain+Birdt Simple To Set r (SST) Setup & Operation Instructions English Installation...2 Tools and Supplies Needed...2 Step 1. Mount r...2 Step 2. Connect Power...2 Indoor r...2 Outdoor r...2 Step 3. Connect
Advanced Data Capture and Control Systems
Advanced Data Capture and Control Systems Tronisoft Limited Email: [email protected] Web: www.tronisoft.com RS232 To 3.3V TTL User Guide RS232 to 3.3V TTL Signal Converter Modules P/N: 9651 Document
Ordering Part Numbers:
TECHNICAL DATASHEET #TDAX021500 HYDRAULIC FAN CONTROLLER Application Platform 3 erature Sensors 4 Digital Command Interfaces 1 PWM Input and 1 Analog Input 1 Proportional or ON/OFF Current Output RS232
T-100-R Installation Guide
T-100-R Installation Guide Table of Contents Page 2 Overview T-100-R Z-Wave Thermostat 3-4 Installation HVAC System Setup 6 Installer Settings Menu Items 7-9 Installer Settings Summary 10-11 Wiring Standard
Temp. & humidity Transmitter Instructions
Temp. & humidity Transmitter Instructions AQ3485/AQ3485Y www.aosong.com 1 Product Overview AQ3485/ AQ3485Y outdoor network temperature and humidity transmitter is accurate measurement of relative humidity
RS - SPM. Serial parallel translator module
ReSatron GmbH Boisheimer Str. 162 D-41751 Viersen Telefon (+49) 02162-45 06 80 Telefax (+49) 02162-45 03 04 email: [email protected] RS - SPM Serial parallel translator module RSSPM000215SPM-021 - Subject
ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme 2015 - Alle Rechte vorbehalten
ALL-USB-RS422/485 USB to Serial Converter RS422/485 User Manual ALL-USB-RS422/485 USB to RS-422/485 Plugin Adapter This mini ALL-USB-RS422/485 is a surge and static protected USB to RS-422/485 Plugin Adapter.
How To Use A Ci 2001A/B (I2) With A Power Supply (I3)
Weighing Indicator CI-2001A/B OWNER S MANUAL CONTENTS PRECAUTIONS 4 INTRODUCTION 6 THE FEATURES OF CI-2001A/B 6 TECHNICAL SPECIFICATION 7 DIMENSIONS 8 FRONT PANEL(CI-2001A) 9 FRONT PANEL(CI-2001B) 11 REAR
MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS
MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.
4-Channel Thermometer / Datalogger
USER GUIDE 4-Channel Thermometer / Datalogger RTD and Thermocouple Inputs Model SDL200 Introduction Congratulations on your purchase of the Extech SDL200 Thermometer, an SD Logger Series meter. This meter
Model SRMD Setra Remote Monitoring Display
Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for
EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information
London Electronics Limited Warren Court, Chicksands, Shefford, Bedfordshire SG17 5QB Tel +44(0)1462-850967 Fax +44(0)1462-850968 www.london-electronics.com [email protected] Ethernet to RS232
Bluetooth Serial Adapter
RN-BT-SRL-UM Bluetooth Serial Adapter 0 Roving Networks. All rights reserved. RN-BT-SRL-UM-.0 Version.0 //0 USER MANUAL RN-BT-SRL-UM-.0 OVERVIEW Roving Networks offers a variety of Bluetooth serial adapters
RN-XV-RD2 Evaluation Board
RN-XV-RD2 Evaluation Board 2012 Roving Networks. All rights reserved. -1.01Version 1.0 9/28/2012 USER MANUAL OVERVIEW This document describes the hardware and software setup for Roving Networks RN-XV-RD2
App. Note Code: 1M-C APPLICATION NOTE. BACnet to Modbus / Modbus to BACnet Protocol Conversion. Copyright (C) June 2010 Campbell Scientifi c, Inc.
APPLICATION NOTE App. Note Code: 1M-C BACnet to Modbus / Modbus to BACnet Protocol Conversion Copyright (C) June 2010 Campbell Scientifi c, Inc. This application note describes using Alerton's BCM-MDBS
DCDC-USB. 6-34V 10A, Intelligent DC-DC converter with USB interface. Quick Installation Guide Version 1.0c P/N DCDC-USB
DCDC-USB 6-34V 10A, Intelligent DC-DC converter with USB interface Quick Installation Guide Version 1.0c P/N DCDC-USB Introduction The DCDC-USB is a small yet powerful DC-DC power supply designed to power
IntesisBox KNX LG Air Conditioning
IntesisBox KNX LG Air Conditioning Gateway for integration of LG Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB) bus. Direct connection to LG outdoor unit
REGTRONIC OPERATING INSTRUCTIONS
REGTRONIC OPERATING INSTRUCTIONS 1.FEATURES Electrical connection: M12 8-pin connector Preset pressure range 0.05-10 bar with possible full scale regulation. 10 100 mbar adjustable deadband Supply pressure:
Modbus Server SAMSUNG Air Conditioners
IntesisBox Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung Air Conditioning Systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel ) Master TCP Master
MICROSYNC. User Manual. Microgate s.r.l. Via Stradivari, 4 Stradivaristr. 39100 BOLZANO - BOZEN ITALY
MICROSYNC Microgate s.r.l. Via Stradivari, 4 Stradivaristr. 39100 BOLZANO - BOZEN ITALY Pagina 2 di 20 Contents 1. INTRODUCTION... 3 2. DESCRIPTION... 4 3. SWITCHING ON/OFF... 5 4. BASIC USE... 6 5. SYNCHRONIZING
User Guide Reflow Toaster Oven Controller
User Guide Reflow Toaster Oven Controller Version 1.5-01/10/12 DROTEK Web shop: www.drotek.fr SOMMAIRE 1. Introduction... 3 2. Preparation of THE REFLOW CONTROLLER... 4 2.1. Power supply... 4 2.2. USB
Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.
Preliminary TECHNICAL DATASHEET #TDAX020700 HYDRAULIC VALVE CONTROLLER 24 I/O 5 Analog and 6 Digital Inputs 1 Temperature Sensor and 1 RPM Sensor Interface 2 PWM Inputs 6 Proportional and 4 ON/OFF Current
MoTeC USA GPS. Part # M GPS BL Available in 10 Hz or 20 Hz. USER MANUAL Version 1.4
MoTeC USA GPS Part # M GPS BL Available in 10 Hz or 20 Hz. USER MANUAL Version 1.4 MoTeC USA GPS Copyright Motec Systems USA 2008 The information in this document is subject to change without notice. While
Communication Setup Application Note
Communication Setup Application Note This Application Note describes how to install and set up communication between the inverter and the SolarEdge Monitoring Server. This document contains the following
DT105X / PB105 Series
DT105 / Series Cash Drawer Trigger & Printer Beeper User's Manual TM951031-05 Contents Information... 1 Technical And Operational Description... 3 Connections Load Test Specifications......... 5 7 8 Communication
2100 POS System. 2100 User Guide
2100 POS System 2100 User Guide Thank you for selecting UTC RETAIL s innovative Model 2100 Point of Sale solution! This guide is designed to acquaint you with the features and functionality of the 2100
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
GSM Interfacing Board
Campus Component Pvt. Ltd. DISCLAIMER Information furnished is believed to be accurate and reliable at the time of publication. However, Campus Component Pvt. Ltd. assumes no responsibility arising from
Business/Home GSM Alarm System. Installation and User Manual
Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene
Sensing element Polymer humidity capacitor Operating range humidity 0-100%RH; temperature -40~80Celsius Accuracy
Standard AM2302/DHT22 AM2302/DHT22 with big case and wires Digital relative humidity & temperature sensor AM2302/DHT22 1. Feature & Application: *High precision *Capacitive type *Full range temperature
IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions
IMMS-CCC IMMS-CCC Hardwire Central Interface Installation Instructions TABLE OF CONTENTS... Choose a Location... 1 Connections... 2 Operations... 3 Software Configuration... 4 Troubleshooting... 5 Loopback
User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual
ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) User Manual Table of Contents 1 Introduction 2 General specification 3 Installation 4 Pin assignment & function of connectors 5 Drawing
TDAS G5-DB Hardware User s Manual
TDAS G5-DB Hardware User s Manual July 2003 Rev. 1A Table of Contents DTS Support... 3 Introducing the TDAS G5-DB... 4 Summary of TDAS G5-DB Features... 4 Basic Care and Handling... 4 Shock Rating...5
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
User Manual for CH-PFC76810
AA Portable Power Corp www.batteryspace.com, Email: [email protected] User Manual for CH-PFC76810 1. Overview The CH-PFC76810 charger is suitable for charging lithium ion battery packs such as those
PROXIMITY CARD READERS C-10, C-20, C60, C70
Installation Manual PROXIMITY CARD READERS C-10, C-20, C60, C70 VERSION 1.0 CONTENTS 1. General information................................. 3 2. Technical data......................... 4 3. Connection
1. SAFETY INFORMATION
RS-232 Sound Level Meter 72-860A INSTRUCTION MANUAL www.tenma.com 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter
How To Set Up A 366101 Modem (Marc) Model 366101 (Marc) Model 2 (Marr) Model 1 (Marm) Model 4 (Mariar) Model 8 (Marp) Model 6 (Mar
DIN Rail Mounted Leased Line Modem Users Manual 366-101 Rev. 2 Copyright 2008 Miille Applied Research Co., Inc. Houston, Texas This page is left blank intentionally Page i TABLE OF CONTENTS LIST OF FIGURES...
Rev 06 1211. GSM base station. Installation instructions
Rev 06 1211 GSM base station Installation instructions Output string format Baud rate 115200 bps Parity none Data bits 8 Stop bits 1 Flow control none The output string is a modified version of the Sureguard
Mobile Satellite Solutions. A WiWorld Partner SATELLITE TV ANTENNA CONTROLLER RFM-1000/1100 TECHNICAL MANUAL STOW SEARCH
Mobile Satellite Solutions A WiWorld Partner SATELLITE TV ANTENNA CONTROLLER RFM-1000/1100 TECHNICAL MANUAL SEARCH STOW Ver. 1 June 2012 WARNING Make all electrical and coax connections from the controller
EDI Distributor Control Interface Wiring and Setup Instructions
Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls
INSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
WEB log. Device connection plans
WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20160425* Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited,
PERF10 Rubidium Atomic Clock
Owner s Manual Audio Stanford Research Systems Revision 1.0 February, 2011 2 Certification Stanford Research Systems certifies that this product met its published specifications at the time of shipment.
4 Port VGA Video Audio Switch with RS232 control
4 Port VGA Video Audio Switch with RS232 control VS410RVGAA *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario
User's Guide DylosLogger Software Version 1.6
User's Guide DylosLogger Software Version 1.6 The DylosLogger software allows users of Dylos Air Quality Monitors equipped with PC interface to easily record, download, and graph data. The COM port is
SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT
SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT FOR INTELLITOUCH AND EASYTOUCH CONTROL SYSTEMS INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Technical
LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server
Products: EFA with EFA Scan, DVRM and DVMD with Realtime Monitor or Stream Explorer DVMD-B1 LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server Remote control of test and
Connecting the Console Port to a PC
This document covers tasks associated with connecting a console port to a PC, and includes the following topics: Console (rollover) Cable and Adapters Making the physical connection Connecting using HyperTerminal
FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.
56 / Accessories for inverters Accessories for inverters / Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards. FRONIUS STRING
2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide
2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide 1. Introduction Thank you for purchasing this 2-Port RS232/422/485 Combo Serial to USB Adapter.
PM1122 INT DIGITAL INTERFACE REMOTE
PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT front panel description: 1. Clear wireless remotes knob: push this button for more than 2 seconds to clear the list of all assigned wireless remote settings
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
IntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet
NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet The NX-591NE-GSM is a microprocessor-controlled GSM interface module used to connect the NetworX series of control panels to GSM cellular networks
ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system
pool/spa control system ScreenLogic Wireless Connection Kit Installation Guide P/N 520663 - Rev B 8 Technical Support Contact Technical Support at: Sanford, North Carolina (8 A.M. to 5 P.M.) Phone: (800)
WIRELESS STATUS MONITOR
INSTALLATION INSTRUCTIONS WIRELESS STATUS MONITOR (WSM or AUWSM) The most current version of this document is available for download at: http://www.ir-swa.com P/N: M053-032-D Schlage 245 W. Roosevelt Road,
Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7
1 de 7 1. Introduction This Technical Note explains how to configure the Modbus Gateway for Vantage Pro2. The Modbus Gateway allows the easy connection of a PLC (Programmable Logic Controller), RTU (Remote
Integrating Digiquartz MET3 and MET3A Broadband Meteorological Systems with Leica GX1200 Series GPS Receivers
Integrating Digiquartz MET3 and MET3A Broadband Meteorological Systems with Leica GX1200 Series GPS Receivers The standard by which other standards are measured Paroscientific, Inc. 4500 148 th Ave. N.E.
1 Serial RS232 to Ethernet Adapter Installation Guide
Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).
M3 ORANGE Snap-On. User Guide. Product Model: A-SNO-ATYP-060-R00. Compatible Device: M3 ORANGE. Version 2.2 Released in March 2013
M3 ORANGE Snap-On User Guide Product Model: A-SNO-ATYP-060-R00 Compatible Device: M3 ORANGE Version 2.2 Released in March 2013 Contents Copyright and Agreement... 3 Notice. 4 Warnings and Cautions for
SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY
SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY! WARNING - SHOCK HAZARD! TO PREVENT THE POSSIBILITY OF SEVERE PERSONAL INJURY, DEATH, OR EQUIPMENT DAMAGE DUE TO ELECTRICAL
Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc
Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular
Installation Instructions. Wireless Adapter/Repeater. Introduction. 30-3001-887 Rev C
/Repeater Installation Instructions 30-3001-887 Rev C Workstation Ethernet bcx Controller Repeater Repeater Introduction Schneider Electric has designed a device that allows Andover Continuum controllers
* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2
COMMERCIAL INSTALL GUIDE 2 Contents How to Use This Guide: The first section of this guide is designed to assist you with the installation of your DECK Monitoring hardware. The revenue grade meter and
In-System Programmer USER MANUAL RN-ISP-UM RN-WIFLYCR-UM-.01. www.rovingnetworks.com 1
RN-WIFLYCR-UM-.01 RN-ISP-UM In-System Programmer 2012 Roving Networks. All rights reserved. Version 1.1 1/19/2012 USER MANUAL www.rovingnetworks.com 1 OVERVIEW You use Roving Networks In-System-Programmer
SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2
SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2 USER MANUAL Rev. P1.11 September 13, 2006 DeltaV is a trademark of Emerson Process Management, Inc Emerson Process Management, Inc. 1998,
Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 [email protected] www.uni-valve.com. Installation and operating manual
Uni-Valve A /S VENTILER & INSTRUMENTER Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 [email protected] www.uni-valve.com UNI-EL Electric actuator Installation and operating manual Remote position
1.1 Connection. 1.1.1 Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking
POS function Marchen POS-DVR surveillance system is a professional surveillance integrated with POS system. By bringing video and POS transaction data together, the POS-DVR surveillance system provides
Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps
Solar Home System User Manual AEHSHS0110W2L Solar Home System 2 Lamps All rights reserved Specifications subject to change without prior notice 2 Dear Customer, Thank you for purchasing Schneider Electric
INSTALLATION & SERVICE MANUAL. Display Panel
INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed
Disclaimers. Important Notice
Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means,
Universal Vehicle Power Supply 9007AX01. Installation Instructions
Universal Vehicle Power Supply 9007AX01 Installation Instructions Disclaimer Honeywell International Inc. ( HII ) reserves the right to make changes in specifications and other information contained in
Vicon Flash Upgrade Software
INSTRUCTION MANUAL Notes Refer to XX134 NO. XX134-13-01 REV. 1212 Vicon Flash Upgrade Software It is possible to upgrade software for the SurveyorVFT and Surveyor -Mini Camera Domes through a PC using
Wespot. SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE
Wespot SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE EN This manual is published by OPTEX, without any warranty. Improvements and changes to this manual necessitated by typographical errors, inaccuracies
OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder
P R O D U C T G R O U P OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder Manual # 600-0901 November 30, 1999 Rev. D - 99068 DESCRIPTION The ST-888 Mobilecall Display Decoder is a desktop