Manual CX9020. Embedded PC. Version: Date:
|
|
|
- Domenic Waters
- 9 years ago
- Views:
Transcription
1 Manual Embedded PC Version: Date:
2
3 Table of contents Table of contents 1 Foreword Notes on the documentation Safety instructions Documentation issue status Product overview Intended use System overview Technical data Types Architecture overview Battery compartment Micro-SD slot Micro SD card S-UPS: capacitive one-second UPS Mounting and wiring Unpacking, installation and transport Dimensions Installation on the mounting rail Power supply Mounting of passive terminals on the power supply DVI-D port USB connections LAN connections Audio interface (-N020) RS232 connections (-N030) RS422/RS485 connections (-N031) Commissioning Switching on and off Seconds UPS Overview Functions Data Types Error handling and diagnostics LEDs on the basic CPU module LEDs of the power supply in K-bus mode LEDs of the power supply in E-bus mode Faults Decommissioning Disassembly and disposal Appendix Accessories Support and Service Certifications Version: 1.5 3
4 Foreword 1 Foreword 1.1 Notes on the documentation This description is only intended for the use of trained specialists in control and automation engineering who are familiar with the applicable national standards. It is essential that the following notes and explanations are followed when installing and commissioning these components. The responsible staff must ensure that the application or use of the products described satisfy all the requirements for safety, including all the relevant laws, regulations, guidelines and standards. Disclaimer The documentation has been prepared with care. The products described are, however, constantly under development. For that reason the documentation is not in every case checked for consistency with performance data, standards or other characteristics. In the event that it contains technical or editorial errors, we retain the right to make alterations at any time and without warning. No claims for the modification of products that have already been supplied may be made on the basis of the data, diagrams and descriptions in this documentation. Trademarks Beckhoff, TwinCAT, EtherCAT, Safety over EtherCAT, TwinSAFE, XFC and XTS are registered trademarks of and licensed by Beckhoff Automation GmbH. Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owners. Patent Pending The EtherCAT Technology is covered, including but not limited to the following patent applications and patents: EP , EP , DE , DE with corresponding applications or registrations in various other countries. The TwinCAT Technology is covered, including but not limited to the following patent applications and patents: EP , US with corresponding applications or registrations in various other countries. EtherCAT is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany Copyright Beckhoff Automation GmbH & Co. KG, Germany. The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express authorization are prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design. 4 Version: 1.5
5 Foreword 1.2 Safety instructions Safety regulations Please note the following safety instructions and explanations! Product-specific safety instructions can be found on following pages or in the areas mounting, wiring, commissioning etc. Exclusion of liability All the components are supplied in particular hardware and software configurations appropriate for the application. Modifications to hardware or software configurations other than those described in the documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH & Co. KG. Personnel qualification This description is only intended for trained specialists in control, automation and drive engineering who are familiar with the applicable national standards. Description of symbols In this documentation the following symbols are used with an accompanying safety instruction or note. The safety instructions must be read carefully and followed without fail! Serious risk of injury! Failure to follow the safety instructions associated with this symbol directly endangers the life and health of persons. DANGER Risk of injury! Failure to follow the safety instructions associated with this symbol endangers the life and health of persons. WARNING Personal injuries! Failure to follow the safety instructions associated with this symbol can lead to injuries to persons. CAUTION Damage to the environment or devices Failure to follow the instructions associated with this symbol can lead to damage to the environment or equipment. Attention Tip or pointer This symbol indicates information that contributes to better understanding. Note Version: 1.5 5
6 Foreword 1.3 Documentation issue status Version Changes 0.1 Preliminary version 1.0 First publication 1.1 UPS chapter added 1.2 UPS notes added 1.3 Reworked images in chapter battery compartment 1.4 Chapter Technical Data reworked 1.5 Architecture overview added, Chapter Types reworked 6 Version: 1.5
7 Product overview 2 Product overview 2.1 Intended use The device series is a control system designed for DIN rail installation. The system can be installed in the control cabinet or terminal box as required. Only switch the PC off after closing the software Before the Embedded PC is switched off, the software currently running on it should be stopped properly in order to avoid data loss on the hard disk. Please read the section on Switching off. Switch off all system components and uncouple the Industrial PC from the system if the PC is not used for control purposes, e.g. during a function test. To disconnect first pull the first terminal behind the power supply unit (optional), then pull the connectors of the fieldbus connections. System components that have been switched off must be secured against being switched on again. The Embedded PC s power supply unit must be supplied with 24 V DC. Attention Damage to the environment or devices Do not exchange any parts when under power! The exchange of controller parts when live can lead to short-circuits or overvoltages. These can damage the controller itself and connected peripherals (terminals, monitors, input devices, etc.). When components are being fitted or removed, the supply voltage must be switched off. Software knowledge Attention System malfunctions Mandatory software knowledge! Every user must be familiar with any of the functions of the software installed on the PC that he can reach. Version: 1.5 7
8 Product overview 2.2 System overview The system The is a compact, DIN rail-mountable Ethernet control system with 1 GHz ARM Cortex A8 CPU. The connection for the Beckhoff I/O systems is directly integrated into the CPU module. The unit offers automatic bus system identifi cation (K-bus or E-bus) and independently switches in the corresponding mode. The comprises the CPU with two microsd card slots, the internal RAM and 128 kb NOVRAM as nonvolatile memory. The basic configuration also includes two switched Ethernet RJ 45 interfaces, four USB-2.0 interfaces and a DVI-D interface. The RJ 45 interfaces are connected to an internal switch and offer a simple option for creating a line topology without the need for additional Ethernet switches. The operating system is Microsoft Windows Embedded Compact 7. TwinCAT 2 automation software transforms a system into a powerful PLC and Motion Control system that can be operated with or without visualisation. Optionally, the unit can be ordered with a fi eldbus, serial or audio interface. The extended operating temperature range between -25 and +60 C enables application in climatically demanding situations. EtherCAT as a fast I/O system The Embedded PC was developed for optimum interaction with EtherCAT. Interestingly, EtherCAT offers several options for connecting conventional fieldbus systems to the : As an EtherCAT device in terminal form. The PROFIBUS master is available either as a CX1500-M310 or as a EL6731 EtherCAT terminal. In practice, this means that the PROFIBUS master can be positioned exactly where it is required within a machine. It no longer has to be implemented as a plug-in card in the IPC or a master controller in the control cabinet. PLC, Motion Control, interpolation and visualisation As a DIN rail IPC and in conjunction with the TwinCAT software from Beckhoff, the offers the same functionality as large Industrial PCs. In terms of PLC, up to four virtual IEC CPUs can be programmed with up to four tasks each. All IEC languages can be used. Moreover, all TwinCAT functionalities are available for Motion Control applications: In theory, up to 256 axes can be controlled. In addition to simple point-to-point movements, more complex multi-axis functions such as electronic gearbox, cam plates and flying saw can be implemented. In addition to real-time execution of control tasks, the TwinCAT real-time kernel ensures that enough time remains for the user interface (HMI), to communicate with the real-time components via software interfaces such as ADS or OPC. 8 Version: 1.5
9 Product overview For the familiar basic principle applies: it is a programming tool for all controllers. The complete programming of PLC, Motion Control and visualisation is transferable to all PC controls from Beckhoff, which is reassuring in cases where it becomes apparent during a project that more processing power is required after all. In this case a system with higher performance can be used. Optional interfaces: The optional interfaces can be used to connect single-channel fieldbus interfaces. Operation is limited to one interface at a time. If several fieldbus interfaces are required, they can be added as E-bus terminals (EL67xx). The following fieldbus interfaces are available: -N020 = Audio, 3 x 3.5 mm jack plugs, Line-In, Mic-In, Line-Out -N030 = RS232, D-Sub connector, 9-pin -N031 = RS422/RS485,D-Sub socket, 9-pin -B110 = EtherCAT slave, EtherCAT IN und OUT (2 x RJ 45) -M310 = PROFIBUS master, D-Sub socket, 9-pin -B310 = PROFIBUS slave,d-sub socket, 9-pin -M510 = CANopen master, D-Sub socket, 9-pin -B510 = CANopen slave, D-Sub socket, 9-pin -M930 = PROFINET RT, controller Ethernet (2 x RJ 45) -B930 = PROFINET RT, device, Ethernet (2 x RJ-45-Switch) -B950 = EtherNet/IP slave, Ethernet (2 x RJ-45-Switch) The software In combination with the TwinCAT automation software, the Industrial PC becomes a powerful IEC PLC with up to four user tasks. Additionally, Motion Control tasks can also be executed. Depending on the required cycle time, several servo axes can be controlled. The system is programmed in the same way as other bus controllers: Remote programming via Ethernet This option is used if the basic unit is equipped with Windows Embedded Compact 7. In this case, the system is programmed via a laptop or a desktop PC, which is connected to the CX via Ethernet (network or crossover cable). The programs are developed on the laptop with a standard TwinCAT software licence and then loaded into the target device. Version: 1.5 9
10 Product overview 2.3 Technical data The basic configuration of the includes a 256 MB µsd Flash card. The basic configuration includes two Ethernet RJ-45 interfaces (connected via the internal switch), four USB 2.0 interfaces and a DVI-D interface. Process data The process data must not exceed the maximum size of 3328 bytes. For some projects, the maximum process data size may be lower than 3328 bytes and it depends on the project. Technical Data Processor Internal Flash memory Internal main memory Persistent memory UPS Interfaces Diagnostics LED Clock Operating system Control software Power supply Current supply Max. power loss Dielectric strength Dimensions (H x W x D) Weight Operating/storage temperature Relative humidity Vibration/shock resistant EMC immunity/emission Protection class ARM Cortex -A8, 1 GHz 256 MB MicroSD (optional expandable), 2 x MicroSD card slot 1 GB DDR3 RAM 128 kb NOVRAM integrated 1-Sekunden-UPS integrated (optional) 2 x RJ 45 (Ethernet, internal Switch), 10/100 MBit/s, DVI-D, 4 x USB 2.0, 1 x optional interface 1 x power, 1 x TC status, 2 x bus status, 2 x flash access Internal clock with battery backup for time and date (battery replaceable) Microsoft Windows Embedded Compact 7 TwinCAT 2 PLC runtime or TwinCAT 2 NC PTP runtime 24 V DC (-15 %/+20 %) I/O terminals 2 A 5 W (including system interfaces) 500 Veff (supply/internal electronics) 84 mm x 99 mm x 91 mm approx. 590 g -25 C C / -40 C C 95 % no condensation conforms to EN /EN / 29 conforms to EN / EN IP 20 Further Information: 10 Version: 1.5
11 Product overview 2.4 Types The CPU module can be equipped with different software options for control software. The operating system is limited to "Windows Embedded Compact 7". The TwinCAT automation software transforms a system into powerful PLC and Motion Control system that can be operated with or without visualization. Further system interfaces (pre-installed in the factory) or fieldbus connections can be added to the basic CPU module. The is available in the following types: Table 1: (1 GHz 1 core) Module no operating system Windows Embedded Compact 7 no TwinCAT X X TwinCAT 2 PLC runtime TwinCAT 2 NC runtime TwinCAT 3 XAR X X X - X X - - X X X Note Software Images A list of the different software images can be found in the Software Documentation. Version:
12 Product overview 2.5 Architecture overview The architecture of the Embedded PC is described below. The Embedded PC is based on the ARMv7-A microarchitecture, which was developed by ARM. The following CPU is used in the : i.mx535 Cortex TM -A8 For details on the CPUs please refer to ARM. The memory is connected directly to the CPU. The Embedded PC is available in one memory configuration: with 1GB DDR3 RAM. The memory is not expandable. The Embedded PC has two MicroSD card slots. The CPU provides all required interfaces: 2x switched Ethernet-RJ45 4x USB 2.0 DVI-D Serial interface (CX20x0-N03x) 1 EMI for FPGA for K-/E-Bus and NOV-RAM 2x MicroSD card slots The interfaces USB, DVI, and LAN ports are standard interfaces. They can be used for operating devices that comply with the standard. Only digital signals can be transmitted over the DVI-D interface. The RJ45 interfaces are connected to an internal switch, without the need for additional Ethernet switches. Details of the individual system interfaces are described in separate sections. 12 Version: 1.5
13 Product overview 2.6 Battery compartment The battery compartment is located under the front cover of the CX20x0. The opening in which the battery bracket is mounted can be seen when the front cover is opened. The battery is then pulled carefully out of the holder with the help of the ejection tab and then removed. To insert a new battery push it into the battery compartment. Ensure correct polarity. Then close the front cover. The battery change is then complete. The battery is a CR2032 type from Panasonic. The correct specifications are: Battery type CR2032 Electrical properties (at 20 C) nominal nominal voltage capacity 3.0 V 225 mah Standard charge continuous load 0.20 ma Dimensions diameter height weight 20.0 mm 3.20 mm 3.1 g An incorrectly inserted battery may explode! Attention Only use the same battery type (CR2032) from Sanyo or Panasonic. Make absolutely sure that positive and negative terminals of the battery are inserted correctly. (Positive pole on the left) Never open the battery or throw it into a fire. The battery cannot be recharged. Battery maintenance The battery must be replaced every 5 years. Spare batteries can be ordered from Beckhoff Service. Note Version:
14 Product overview 2.7 Micro-SD slot Two µsd Flash slots are located at the front, which enables the storage medium to be replaced. This allows the storage medium to be exchanged. The card in the upper slot (Slot 1) is used for the operating system. The lower slot (Slot 2) is used for an additional µsd card. Here data or further programs can be archvied. The µsd Flash card can be removed from the module for maintenance. This should only be done in switched-off state, otherwise the system may crash. In this way it is also possible to expand the system (only operating system and program memory). MicroSD Flash cards (µsd cards) are available as accessories [} 48] in various sizes. The following images illustrate the handling of the µsd cards. The eject mechanism is based on the pushpush principle: The CFast Flash card is disengaged with a soft click by lightly pressing the card ( with a screwdriver). At the same time the card moves approx. 2-3 mm out of the housing, so that it can be pulled out. When the card is pushed back the eject mechanism locks again. The card is positioned correctly, if it is located approx. 1 mm lower than the front of the housing. 14 Version: 1.5
15 Product overview 2.8 Micro SD card The micro SD Flash Card (µsd Card) is a non-volatile memory. Data to be retained in the event of a power failure should be saved on the µsd card. The µsd card operates like a hard disk. Note Using µsd cards We strongly recommend that only µsd cards supplied by Beckhoff Automation GmbH should be used. These are industrial µsd cards with a higher number of write/read cycles and an extended temperature range (+85 C). Proper operation can only be guaranteed with µsd cards from Beckhoff Automation GmbH! Version:
16 Product overview 2.9 S-UPS: capacitive one-second UPS The _U900 family features a built-in capacitive one-second UPS. It ensures a safe storage of the persistent application data on the Compact Flash card. Up to 1 MB of persistent data can be saved. Integration into a PLC TwinCAT offers special function blocks for integrating the S-UPS into a PLC program. These are described in the chapter Commissioning>1 Second UPS. For TwinCAT 2.11R3 Build 2247 or TwinCAT 3.1 Build 4018 the required library is integrated in the installation. For older versions the library TcSUPS U900.lib has to be copied into the TwinCAT library directory. 16 Version: 1.5
17 Mounting and wiring 3 Mounting and wiring 3.1 Unpacking, installation and transport The specified storage conditions must be adhered to (see "Technical data"). Dimensions and weight of the individual modules: Dimensions (W x H x D): 144 mm x 100 mm x 91 mm Weight: approx g / 1165g / 1230 g (basic module) Unpacking Proceed as follows to unpack the unit: 1. Remove packaging. 2. Do not discard the original packaging. Keep it for transporting the device in the future. 3. Check the delivery for completeness by comparing it with your order. 4. Please keep the associated paperwork. It contains important information for handling the unit. 5. Check the contents for visible shipping damage. 6. If you notice any shipping damage or inconsistencies between the contents and your order, you should notify Beckhoff Service. Attention Danger of damage to the device! During transport in cold conditions, or if the device is subjected to extreme temperature differences, condensation on and inside the device must be avoided. Prior to operation, the device must be allowed to slowly adjust to room temperature. Should condensation occur, a delay time of approximately 12 hours must be allowed before the unit is switched on. Installation The devices are designed for installation in control cabinets. Shipping and relocation Despite the robust design of the unit, the components are sensitive to strong vibrations and impacts. During transport, your computer should therefore be protected from excessive mechanical stress. Therefore, please use the original packaging. Version:
18 Mounting and wiring 3.2 Dimensions The following drawing shows the dimensions of the devices. Dimensions 18 Version: 1.5
19 Mounting and wiring 3.3 Installation on the mounting rail Snapping onto the mounting rail The can simply be snapped onto the mounting rail. The bar clips are inserted on the top side and underside Then simply position the block on the mounting rail and push it slightly until it engages on the right-hand side. This is indicated by a distinct click. The bars are then engaged again. The engagement of the individual bars is indicated by a distinct click. Avoid damage! Do not force the module or apply excessive pressure! Attention Installation position Attention Comply with the permitted installation position and minimum distances! The maximum ambient temperature for CPU modules mounted on a top-hat rail is 60 C. The orientation in which the device is fitted must be selected in such a way that cooling air can flow vertically through the ventilation holes. The images below show the permitted and two incorrect installation positions. Mounting must provide a clearance of 30 mm both above and below a device combination to ensure adequate ventilation of the base CPU module and the power supply unit. Version:
20 Mounting and wiring Correct installation position The high performance and the compact design of the systems may result in increased heat generation. The heat is dissipated via a passive ventilation system. This system requires the unit to be mounted correctly. Ventilation openings are located at the top and bottom of the housing. The system therefore has to be installed horizontally. This ensures optimum air flow. Incorrect installation positions The system must not be operated vertically on the top-hat rail. A vertical position would lead to insufficient CPU ventilation, since the ventilation openings are located on the top and bottom of the housing. Installation of the system on its side would also lead to inadequate ventilation. invalid installation position invalid installation position 20 Version: 1.5
21 Mounting and wiring 3.4 Power supply This power supply unit is equipped with an I/O interface, which permits connection of the Beckhoff Bus Terminals. The power is supplied via the upper spring-loaded terminals labeled 24V and 0V. The supply voltage supplies the CX system ant the terminal Bus and Bus Terminal with a voltage of 24 V DC (-15 %/+20 %). The dielectric strength of the power supply unit is 500 Vrms. Since the Terminal Bus (K- and E-bus) only transfers data, a separate power supply is required for the Bus Terminals. This is provided by means of the power contacts, which are not connected to the power supply. Requirements for the 24V power supply The power supply must be capable to supply 4A at 24 V to guarantee proper function of CPU module and terminals. Version:
22 Mounting and wiring The terminals are implemented in spring force technology. Connect the cables as follows: 1. Open a spring-loaded terminal by slightly pushing with a screwdriver or a rod into the square opening above the terminal. 2. The wire can now be inserted into the round terminal opening without any force. 3. The terminal closes automatically when the pressure is released, holding the wire securely and permanently. Wire size width mm 2 AWG 20.. AWG 14 Wire stripping length mm 0.33 inch LED If the power supply unit is connected correctly and the power supply is switched on, the two upper LEDs in the terminal prism are green. The left LED (Us) indicates the CPU supply. The right LED (Up) indicates the terminal supply. The other LEDs indicate the Terminal Bus status. A detailed description of the LEDs can be found in section "LED troubleshooting". Power contact PE Attention Attention Powerkontakt "PE" The PE power contact must not be used for other potentials. "PE" und "0V" (24V CX-System supply) have to be on the same potential. (connected in the cabinet) Der Powerkontakt "PE" darf nicht für andere Potentiale verwendet werden. "PE" und "0V" (24V Systemversorgung) müssen auf dem gleichen Potential liegen. (im Schaltschrank verbunden) The wiring the cabinet has to follow the Norm EN EN :2006: Safety of machinery - Electrical equipment of machines - (PELV = Protective Extra Low Voltage)EN :2006 chapter 6.4.1:b): One side of the circuit or a point of the energy source of the circuit must be connected to protective earth system Interrupt power supply / switching off If the power supply should be disconnected the "0V" must not be disconnected. Always disconnect the 24V wire first. Otherwise there can be electrical current flow via the shield. Possibly connected devices with own power supply (e.g. panel) must have the same electrical potential for "PE" and "GND" as the CX-unit. Otherwise the CX-unit and/or the connected device can be damaged. 22 Version: 1.5
23 Mounting and wiring 3.5 Mounting of passive terminals on the power supply Note on the mounting of passive terminals Note EtherCAT Bus Terminals (ELxxxx/ESxxxx) that do not actively participate in data exchange within the Bus Terminal block are called passive terminals. These terminals can be recognised by their lack of power consumption from the E-Bus. In order to ensure optimal data exchange, these may not be connected directly in-line to the power supply! Examples of the mounting of passive terminals (coloured dark): The following drawing shows impermissible mounting: The following illustration shows the correct mounting of the passive terminal: Version:
24 Mounting and wiring 3.6 DVI-D port DVI-D port (X200) The DVI-D interface transfers digital data and is suitable for connecting a digital display. The resolution at the display or the Beckhoff Control Panel depends on the distance from the display device. The maximum distance is 5 m. Beckhoff offers various Panels with an integrated DVI extension. These make a cable length of up to 50 meters possible. Note DVI-D Interface The DVI interface does not use VGA signals, so that the connection of CRT VGA monitors to the system using a DVI to VGA adapter is not possible. DVI-D socket Pin Assignment Pin Assignment Pin Assignment 1 TMDS Data 2-9 TMDS Data 1-17 TMDS Data 0-2 TMDS Data TMDS Data TMDS Data 0+ 3 TMDS Data 2/4 Shield 11 TMDS Data 1/3 Shield 19 TMDS Data 0/5 Shield 4 not connected 12 not connected 20 not connected 5 not connected 13 not connected 21 not connected 6 DDC Clock V Power 22 TMDS Clock Shield 7 DDC Data 15 Ground ( +5V, Analog H/V Sync) 23 TMDS Clock + 8 Analog Vertical Sync 16 Hot Plug Detect 24 TMDA Clock - 24 Version: 1.5
25 Mounting and wiring Resolution at the monitor Resolution in pixels Distance of the interface from the monitor 1920 x m 1920 x m 1600 x m 1280 x m 1024 x m 800 x m 640 x m The Embedded PC also supports higher resolutions according to the DVI standard. A maximum resolution of 2560 x 1440 pixels can be set on the Embedded PC. Whether this resolution is achieved is dependent on the monitor, the cable quality and cable length. Version:
26 Mounting and wiring 3.7 USB connections USB interface (X100 / X101 / X102 / X103): The has 4 independent USB interfaces, for connecting keyboards, mice, touchscreens and other input or data storage devices. Attention is thereby to be paid to the power consumption of the individual devices: No more than 500 ma can be output per port. The USB socket is a type A socket. The USB interface complies with the USB 2.0 specification. Pin Assignment Typical assignment 1 VBUS Red 2 D- White 3 D+ Green 4 GND Black Shell Shield Drain Wire 26 Version: 1.5
27 Mounting and wiring 3.8 LAN connections LAN interface (X000/ X001) The systems have two switched LAN interfaces. Both ports are able to operate at speeds of 10 / 100 Mbit. The LEDs on the left-hand sides of the RJ45 sockets indicate the status of the LAN connection. The upper LED indicates whether the port is connected to a network. The LED flashes if data traffic takes place on the port (Link /Activity). The lower LED indicates the connection speed. The LED is off if the speed is 10 Mbit. In 100 Mbit mode the LED is green. Table 2: Configuration of the RJ45 interface, port 1 (X000) / port 2 (X001) PIN Signal Description 1 TD + Transmit + 2 TD - Transmit - 3 RD + Receive + 4 connected not used 5 6 RD - Receive - 7 connected not used 8 Note Dependence of the ports Both ports are dependent of each other. In contrast to the CX50x0 and CX20x0 systems, one switch is integrated. For a line topology no further switch is required. Version:
28 Mounting and wiring 3.9 Audio interface (-N020) This system interface provides the audio interface for the system. Two inputs, "LINE IN" (X300) and "MIC IN" (X302), are available. The "LINE OUT" (X301) connection is used as output for audio signals. It can also be used for connecting headphones with a maximum output of 200 mw. The audio interfaces are accessed via the operating system. The 3.5 mm sockets are designed for jack plugs. Standard / stereo mode: The audio module operates in stereo mode as standard, using stereo outputs/inputs and a single-channel input for the microphone. The inputs should be connected as indicated. The pin assignments are described below. Line In / Line Out stereo jack plugs (X300 / X302): Table 3: Pin assognment Line In /Line Out: Signal L R Ground Description Left channel right channel Ground The left channel is transferred via the tip of the jack plug, the right channel via the first ring. The remainder of the sleeve is used for earthing. Mic In mono jack plug (X301): 28 Version: 1.5
29 Mounting and wiring The only existing channel is transferred via the tip, the remainder of the sleeve is used for earthing. The audio settingsa can be done via the Beckhoff CX-Configuration Tool. Open the tool via Startmenue -> Control Panel -> CX Configuration Navigate to tab "Miscellaneous" to change audio settings. The checkbox "Enable Audio Device" enables or disables the interface. With "Audio Settings" a "Mixer" can be called. The volume for the output and input is selected with the slider. The input source can be selected with "Input select". Only one source (LINE or MIC) can be active at once. "OK" confirms these settings. Version:
30 Mounting and wiring 3.10 RS232 connections (-N030) The -N030 system interface provides an RS232 interface, COM1 (X300). It is implemented on a 9- pole Sub-D pin strip. If more than one interface is required the system can be extended via the Terminal Bus (K- or E-bus) or Bus Terminals (KL/EL6001) which provide serial interfaces. The pin assignment is shown at the bottom of the page. The maximum baud rate on both channels is 115 kbit. The interface parameters are set via the operating system or from the PLC program. RS232 COM interface (connector) Table 4: Pin assignment of the COM interface PIN Signal Type Description 2 RxD Signal in Receive Data 3 TxD Signal out Transmit Data 5 GND Ground Ground 7 RTS Signal out Ready to Send 8 CTS Signal in Clear to Send 30 Version: 1.5
31 Mounting and wiring 3.11 RS422/RS485 connections (-N031) The -N030 system interface provides an RS422 or RS 485 interface, COM1 (X300). It is implemented on a 9-pole Sub-D socket strip. If more than one interface is required the system can be extended via the Terminal Bus (K- or E-bus) or Bus Terminals (KL/EL6021) which provide serial interfaces. The pin assignment is shown at the bottom of the page. The maximum baud rate on both channels is 115 kbit. The interface parameters are set via the operating system or from the PLC program. COM interface (socket) Table 5: Pin assignment of the COM interface PIN Signal Type Description 2 TxD+ Data-Out + Transmit RxD+ Data-In + Receive GND Ground Ground 6 VCC VCC +5V 7 TxD- Data-Out - Transmit RxD- Data-In - Receive 422 For RS 485 pins 2 and 3 (data +) must be connected, and pins 7 and 8 (data -). Setting the interface parameters The interface is parameterised as follows in the delivery condition: Table 6: RS485 without echo, end point (terminated) standard setting Function Echo on Echo off Auto send on Always send on Auto receive on Always receive on Term on Term on Status off on on off on off on on Version:
32 Mounting and wiring Note Changing the interface parameters If parameters other than those set should be required, please choose the right order number: - -N RS485 with Echo, End-Point (Terminated) - -N RS485 without Echo, Drop-Point (not Terminated) - -N RS485 with Echo, Drop-Point (not Terminated) - -N RS422 Full Duplex, End-Point (Terminated) 32 Version: 1.5
33 Commissioning 4 Commissioning 4.1 Switching on and off Switching on The power supply for the basic CPU module comes from the power supply unit. The basic CPU module starts automatically when the power supply unit is connected to the mains. Switching on for the first time When you switch on the PC for the first time, the pre-installed operating system (optional) will be started. Switching off The Embedded PC switches off when the power supply unit is switched off. The control software typically running on Embedded PCs should be shut down or stopped correctly. A user who may not close software may also not switch the Embedded PC off, since data can be lost from the hard disk by switching off while software is running. Once the software has been stopped, the operating system can be shut down. Only then should the power supply be interrupted. Version:
34 Commissioning Seconds UPS Overview The library TcSUPS U900.lib includes functions and function blocks required for controlling the one-second UPS. Function blocks Name FB_S_UPS U900 FB_NT_QuickShutdown Description Block for controlling the one-second UPS Internal block for QuickShutdown, used by the FB_S_UPS. Functions Name F_GetVersionTcSUPS U900 Description This function can be used to read PLC library version information. Component TwinCAT on the development PC and on the control system Version TwinCAT 2.11R3 Build 2047 or higher FUNCTION_BLOCK FB_S_UPS U900 The function block FB_S_UPS U900 can be used on CX devices with one-second UPS to control the one-second UPS from the PLC. This allows the persistent data to be saved and a quick shutdown to be performed in the event of a power failure. If possible the default values of the INPUTs of the FB_S_UPS U900 should be retained. Attention Loss of data The seconds UPS can be used only for a few seconds in the event of a power failure in order, to save persistent data. The data must be saved in the fast persistent mode SPDM_2PASS, even though this can lead to real-time violations. Sufficient router memory must be configured for the storage of the persistent data! The second UPS does not have sufficient capacity for bridging power failures. Only the CFast card can be used for data storage, in view of the fact that the UPS capacity is inadequate for operating a hard disk. A QuickShutdown is performed automatically in the esups_wrpersistdata_shutdown mode (standard setting) after the storage of the persistent data. In esups_wrpersistdata_noshutdown mode only the persistent data are stored. No QuickShutdown is executed. In the esups_immediateshutdown mode a QuickShutdown is executed immediately without saving data. 34 Version: 1.5
35 Commissioning In the esups_checkpowerstatus mode only a check is performed as to whether a power failure has occurred. If this is the case, the module only switches back to the PowerOK state after the expiry of trecovertime (10s). Independent of the mode and thus independent of the saving or the shutting down of the controller, the UPS switches the main board off after the capacitors have discharged, even if the voltage has returned in the meantime. Attention Caution when using files: If other applications or the PLC keep other files open or write to them, this can lead to faulty files if the UPS switches off the controller. FUNCTION_BLOCK FB_S_UPS U900 VAR_INPUT VAR_INPUT snetid : T_AmsNetId := ''; (* '' = local netid *) iplcport : UINT := AMSPORT_R0_PLC_RTS1; (* PLC Runtime System for writing persistent data *) iupsport : UINT := 16#4A8; (* Port for reading Power State of UPS, dafault 16#4A8 *) ttimeout : TIME := DEFAULT_ADS_TIMEOUT; (* ADS Timeout *) eupsmode : E_S_UPS_Mode := esups_wrpersistdata_shutdown; (* UPS mode (w/wo writing persistent data, w/wo shutdown) *) epersistentmode : E_PersistentMode := SPDM_2PASS; (* mode for writing persistent data *) trecovertime : TIME := T#10s; (* ON time to recover from short power failure in mode es- UPS_WrPersistData_NoShutdown/eSUPS_CheckPowerStatus *) END_VAR E_S_UPS_Mode snetid : AmsNetID of the controller. iplcport : Port number of the PLC runtime system (AMSPORT_R0_PLC_RTS1 = 801, AMSPORT_R0_PLC_RTS2 = 811, AMSPORT_R0_PLC_RTS3 = 821, AMSPORT_R0_PLC_RTS4 = 831). iupsport : Port number via which the UPS status is read (standard value is 16#4A8). ttimeout : Timeout for the execution of the QuickShutdown. eupsmode : The eupsmode defines whether persistent data are to be written and whether a QuickShutdown is to be performed. Standard value is esups_wrpersistdata_shutdown, i.e. with writing of the persistent data and then QuickShutdown. See E_S_UPS_Mode. epersistentmode : Mode for the writing of the persistent data. Standard value is SPDM_2PASS. trecovertime : Time after which the UPS reverts to the PowerOK status in the case of UPS modes without shutdown. The trecovertime must be somewhat longer than the maximum holding time of the UPS, since the UPS switches off even when the voltage returns. VAR_OUTPUT VAR_OUTPUT bpowerfaildetect : BOOL; (* TRUE while powerfailure is detected *) estate : E_S_UPS_State; (* current ups state *) END_VAR E_S_UPS_State bpowerfaildetect : True during the power failure; False if the supply voltage is present. estate : Internal state of the function block, for values see E_S_UPS_State. Version:
36 Commissioning VAR_GLOBAL VAR_GLOBAL eglobalsupsstate : E_S_UPS_State; (* current ups state *) END_VAR E_S_UPS_State eglobalupsstate : Internal state of the function block as a global copy of the VAR_OUTPUT estate; for values see E_S_UPS_State. Prerequisites Development environment Target platform Hardware PLC libraries to include TwinCAT v2.11r3 Build 2047 or higher PC (i386) Seconds UPS TcSUPS U900. Lib FUNCTION_BLOCK FB_NT_QuickShutdown The function block FB_NT_QuickShutdown can be used to trigger an immediate reboot, without stopping TwinCAT or the Windows operating system. Attention: Attention Loss of data The function block FB_NT_QuickShutdown is used internally by FB_S_UPS U900. It must not be used independently, because this could result in data loss! FUNCTION_BLOCK FB_NT_QuickShutdown VAR_INPUT VAR_INPUT NETID :T_AmsNetId; START :BOOL; TMOUT :TIME := DEFAULT_ADS_TIMEOUT; END_VAR NETID : AmsNetID of the controller. START : Rising edge leads to immediate reboot of the control system. TMOUT : Time out period. VAR_OUTPUT VAR_OUTPUT BUSY :BOOL; ERR :BOOL; 36 Version: 1.5
37 Commissioning ERRID :UDINT; END_VAR BUSY : QuickShutdown is executed. ERR : Becomes TRUE, as soon as an error occurs. ERRID : Supplies the error number when the ERR output is set. Prerequisites Development environment Target platform Hardware PLC libraries to include TwinCAT v2.11r3 Build 2047 or higher PC (i386) One-second UPS TcSUPS U900. Lib Version:
38 Commissioning Functions FUNCTION F_GetVersionTcSUPS U900 This function can be used to read PLC library version information. FUNCTION F_GetVersionTcSUPS U900 : UINT VAR_INPUT nversionelement : INT; END_VAR nversionelement : Version element to be read. Possible parameters: 1 : major number 2 : minor number 3 : revision number Prerequisites Development environment Target platform Hardware PLC libraries to include TwinCAT v2.11r3 Build 2047 or higher PC (i386) Seconds UPS TcSUPS U900. Lib 38 Version: 1.5
39 Commissioning Data Types TYPE E_S_UPS_Mode esups_wrpersistdata_shutdown: write persistent data and then QuickShutdown esups_wrpersistdata_noshutdown: write persistent data only (no QuickShutdown) esups_immediateshutdown: QuickShutdown only (no writing of persistent data) esups_checkpowerstatus: determine status only (neither write persistent data nor QuickShutdown) Prerequisites Development environment Target platform Hardware PLC libraries to include TwinCAT v2.11r3 Build 2047 or higher PC (i386) Seconds UPS TcSUPS U900. Lib TYPE E_S_UPS_State esups_powerok: in all modes: supply voltage is OK esups_powerfailure: in all modes: Supply voltage faulty (applied for one cycle only) esups_writepersistentdata: in esups_wrpersistdata_shutdown mode: writing of the persistent data is active in esups_wrpersistdata_noshutdown mode: writing of the persistent data is active esups_quickshutdown: in esups_wrpersistdata_shutdown mode: QuickShutdown is active in esups_immediateshutdown mode: QuickShutdown is active esups_waitforrecover: in esups_wrpersistdata_noshutdown mode: wait for return of the voltage in esups_checkpowerstatus mode: wait for return of the voltage esups_waitforpoweroff: in esups_wrpersistdata_shutdown mode: wait for shutdown by the UPS in esups_immediateshutdown mode: wait for shutdown by the UPS Prerequisites Development environment Target platform Hardware PLC libraries to include TwinCAT v2.11r3 Build 2047 or higher PC (i386) Seconds UPS TcSUPS U900. Lib Version:
40 Error handling and diagnostics 5 Error handling and diagnostics 5.1 LEDs on the basic CPU module Display LED Meaning PWR TC FB1 FB2 HDD 1 HDD 2 Power supply The Power LED comes on when the device is connected to a live power supply unit (green). The LED blinks fast (red) if there is a power failure. The LED blinks slow (red) if there is no or an incorrect µsd card inserted. TwinCAT status LED TwinCAT is in Run mode (green) TwinCAT is in Stop mode (red) TwinCAT is in Config mode (blue) Status LED1 for fieldbus (function is written at the fieldbus interface) Status LED2 for fieldbus (function is written at the fieldbus interface) Indicates access to the µsd card in slot 1. LED flashes green during read access. LED flahes yellow during write access. Indicates access to the µsd card in slot 2. LED flashes green during read access. LED flahes yellow during write access. 40 Version: 1.5
41 Error handling and diagnostics 5.2 LEDs of the power supply in K-bus mode After switching on, the power supply immediately checks the connected Bus Terminal configuration. Errorfree start-up is signalled by the red "I/O ERR LED being extinguished. If the I/O ERR LED blinks, an error in the area of the terminals is indicated. The error code can be determined from the frequency and number of blinks. This permits rapid rectification of the error. Display LED Meaning Us 24 V Up 24V K-BUS RUN K-BUS ERR Power supply for the CPU module. The LED lights green if the power supply is correct. Power supply for terminal bus. The LED lights green if the power supply is correct. K-bus diagnostics. The green LED lights up in order to indicate fault-free operation. "Fault-free" means that the communication with the fieldbus system is also running. K-bus diagnostics. The red LED flashes to indicate an error. The red LED blinks with two different frequencies. The I/O error LED blink code Fast blinking First slow sequence Second slow sequence Start of the error code Error code Error code argument Version:
42 Error handling and diagnostics LEDs for K-bus diagnostics Error code Persistent, continuous flashing Error code argument Description EMC problems Remedy - Check power supply for overvoltage or undervoltage peaks - Implement EMC measures If a K-Bus error is present, it can be localized by a restart of the power supply (by switching it off and then on again) 3 pulses 0 K-bus command error - No Bus Terminal inserted 4 pulses 0 K-Bus data error, break behind the power supply n Break behind Bus Terminal n 5 pulses n K-bus error in register communication with Bus Terminal n - One of the Bus Terminals is defective; halve the number of Bus Terminals attached and check whether the error is still present with the remaining Bus Terminals. Repeat until the defective Bus Terminal is located. Check whether the n+1 Bus Terminal is correctly connected; replace if necessary. Check whether the Bus End Terminal 9010 is connected. Exchange the nth bus terminal 6 pulses 0 Error at initialization Exchange Bus Coupler 1 Internal data error Perform a hardware reset on the Bus Coupler (switch off and on again) 8 Internal data error Perform a hardware reset on the Bus Coupler (switch off and on again) 7 pulses 0 Process data lengths of the set and actual configurations do not correspond Check configuration and terminals for consistency Error code argument The number of pulses indicates the position of the last Bus Terminal before the fault. Passive Bus Terminals, such as a power feed terminal, are not included in the count. In the case of some errors, rectification does not cause the power supply to leave the blink sequence. The power supply can only be restarted by switching its supply voltage off and on again. The CX unit recognizes these terminals automatically on scanning, reads out the terminal types and automatically places them in the System Manager. 42 Version: 1.5
43 Error handling and diagnostics K-bus state The K-bus status is saved in the state byte (see fig. K-bus interface 1 ). If the value is 0 the K-bus is operating synchronously and without errors. If the value is <> 0 there may be a fault, or it may only be an indication that the K-bus cycle is longer than the task, in which case it would no longer by synchronous with the task. The task time should be faster than 100 ms. We recommend a task time of less than 50 ms. The K- bus update time typically lies between one and five ms. Bit 0 = K-Bus error Bit 1 = terminal configuration has changed since the start Bit 2 = process image lengths do not match Bit 8 = no valid inputs (yet) Bit 9 = K-bus input update not yet complete Bit 10 = K-bus output update not yet complete Bit 11 = watchdog Bit 15 = acyclic K-bus function active (e.g. K-bus reset) If there is a K-bus error, this can be reset via the IOF_DeviceReset function block (in the TcIoFunctions.lib). Version:
44 Error handling and diagnostics 5.3 LEDs of the power supply in E-bus mode After switching on, the power supply immediately checks the connected Bus Terminal configuration. In the E- Bus mode the L/A led lights up. It starts blinking when there is traffic on the bus. Display LED Meaning Us 24 V Up 24 V Power supply for the CPU module The LED lights green if the power supply is correct. Power supply for terminal bus. The LED lights green if the power supply is correct. L/A off E-bus not connected on flashing E-bus connected / no data traffic E-bus connected / data traffic on the E-bus. 44 Version: 1.5
45 Error handling and diagnostics 5.4 Faults Please also refer to the Safety instructions section. Possible faults and their correction Fault Cause Measures no function after the Embedded PC has been switched on Embedded PC does not boot fully Computer boots, software starts, but control does not operate correctly no power supply for the Embedded PC other causes Hard disk damaged (e.g. due to switching off while software is running), incorrect setup,other causes Cause of the fault is either in the software or in parts of the plant outside the Embedded PC 1. Check fuse 2. Measure voltage at connection, check plug wiring Call Beckhoff support Check setup Call Beckhoff support Call the manufacturer of the machine or the software. µsd card access error Faulty µsd card, faulty card slot Use a different µsd card to check the card slot Call Beckhoff support Embedded PC only works partially or temporarily Defective components in the Embedded PC Call Beckhoff support Please make a note of the following information before contacting Beckhoff service or support: 1. Precise device ID: CXxxxx-xxxx 2. Serial number 3. Hardware version 4. Any interfaces (N030, N031, B110,...) 5. TwinCAT version used 6. Any components / software used The quickest response will come from support / service in your country. Therefore please contact your regional contact. For details please refer to our website at or ask your distribution partner. Version:
46 Decommissioning 6 Decommissioning 6.1 Disassembly and disposal A hardware configuration is dismantled in 2 stages: 1. Switching off and disconnecting the power supply Before a system can be dismantled, the system should be switched off, and the power supply should be disconnected. 2. Removing from the top-hat rail: Before the individual modules are disconnected, the whole hardware block should be removed from the top-hat rail. Proceed as follows: 2.1. Release and remove the first Terminal next to the power supply unit on the tophat rail. First remove any wiring from power supply unit and then from the first terminal on the top-hat rail next to the power supply unit. If the wiring is to be reused for another system, it is advisable to make a note of the connections. Then pull the orange terminal release (see arrow) to release the terminal and pull it out Releasing the systems To release the block, release the orange DIN rail bracket on the left-hand side of the device. Push back the lower hook. An audible click indicates that the device is released. 46 Version: 1.5
47 Decommissioning After pulling the terminal release of the power supply unit, the block can be removed carefully from the tophat rail. Attention Do not use force to open the device! Opening the module housing by force would destroy it. The devices may only be opened by Beckhoff service personnel. Disposal The device must be fully dismantled in order to dispose of it. Electronic parts must be disposed of in accordance with national electronics scrap regulations. Version:
48 Appendix 7 Appendix 7.1 Accessories MicroSD cards instead of the 512 MB microsd card oder number CX CX CX CX Description 1 GByte microsd card, instead of 512 MB microsd card 2 GByte microsd card, instead of 512 MB microsd card 4 GByte microsd card, instead of 512 MB microsd card 8 GByte microsd card, instead of 512 MB microsd card spare microsd cards oder number CX CX CX CX CX Description 512 MByte microsd card 1 GByte microsd card 2 GByte microsd card 4 GByte microsd card 8 GByte microsd card Passive DVI-to-VGA adaptor Order number CX Description Passive DVI-to-VGA adaptor for the connection of standard VGA monitors to the CX system feeds out the VGA signals of the DVI-I interface of the CX module DVI-A plug, 29-pin (bottom), socket, 15-pin (top) Weight: approx. 40 g Dimensions (W x H x D): 40 x 42 x 15 mm Spare battery for CX-Systems oder number CX Description Battery for the CX-Systems - original product description: Panasonic type CR2032 3V/225mAh 48 Version: 1.5
49 Appendix 7.2 Support and Service Beckhoff and their partners around the world offer comprehensive support and service, making available fast and competent assistance with all questions related to Beckhoff products and system solutions. Beckhoff's branch offices and representatives Please contact your Beckhoff branch office or representative for local support and service on Beckhoff products! The addresses of Beckhoff's branch offices and representatives round the world can be found on her internet pages: You will also find further documentation for Beckhoff components there. Beckhoff Headquarters Beckhoff Automation GmbH & Co. KG Huelshorstweg Verl Germany Phone: +49(0)5246/963-0 Fax: +49(0)5246/ Beckhoff Support Support offers you comprehensive technical assistance, helping you not only with the application of individual Beckhoff products, but also with other, wide-ranging services: support design, programming and commissioning of complex automation systems and extensive training program for Beckhoff system components Hotline: +49(0)5246/ Fax: +49(0)5246/ Beckhoff Service The Beckhoff Service Center supports you in all matters of after-sales service: on-site service repair service spare parts service hotline service Hotline: +49(0)5246/ Fax: +49(0)5246/ Version:
50 Appendix 7.3 Certifications All products of the Embedded PC family are CE, UL and GOST-R certified. Since the product family is continuously developed further, we are unable to provide a full listing here. The current list of certified products can be found at FCC Approvals for the United States of America FCC: Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC Approval for Canada FCC: Canadian Notice This equipment does not exceed the Class A limits for radiated emissions as described in the Radio Interference Regulations of the Canadian Department of Communications. 50 Version: 1.5
Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!
Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8
C ed P d ed b Em 184
184 Modular DIN rail IPCs and Industrial Motherboards 185 186 190 s 254 Industrial Motherboards Embedded Automation 187 190 192 196 198 202 202 203 203 204 204 205 205 205 s Product overview System description
Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20
Documentation for KL2602 and KL2622 Two-channel Relay Output Terminals for 230 V AC / 30 V DC Version: 1.4 Date: 2013-03-20 Table of contents Table of contents 1 Foreword 1 1.1 Notes on the documentation
Installation and Operating instructions for. Control Cabinet Industrial PC C6240-1007. Version: 1.3 Date: 2014-12-02
Installation and Operating instructions for Control Cabinet Industrial PC C6240-1007 Version: 1.3 Date: 2014-12-02 Table of contents Table of contents 1. 2. 3. Foreword 3 Notes on the Documentation 3
1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions
Facility Pilot Server Art. No. : FAPV-SERVER-REG Facility Pilot Server Art. No. : FAPVSERVERREGGB Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically
Manual TC3 PLC HMI. TwinCAT 3. Version: Date: Order No.: 1.0 2016-01-20 TF1800
Manual TwinCAT 3 Version: Date: Order No.: 1.0 2016-01-20 TF1800 Table of contents Table of contents 1 Foreword... 4 1.1 Notes on the documentation... 4 1.2 Safety instructions... 5 2 PLC HMI... 6 Version:
Manual. Source Control. TwinCAT 3. Version Date 1.0 2015-06-22
Manual TwinCAT 3 Version Date 1.0 2015-06-22 Table of Contents Table of Contents 1 Foreword... 4 1.1 Notes on the documentation... 4 1.2 Safety instructions... 5 2 Integration of the Management... 6 2.1
ZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English
xepi 2 Diagnostic Unit and Configuration Interface Doc. Version 4.0 Installation Guide English Dear Customer, This "Installation Guide" will help you to install the hardware. If you have any further questions,
SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program
Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves
How To Use A Powerline Powerline 2.5D (Powerline) With A Power Supply (Power Supply) And Power Supply Power Supply From A Powerplant (Powerplant) With An Industrial Pc (Powerboard) With Power
Installation and Operating instructions for CP22xx Multi-touch built-in Panel PC Version: 1.3 Date: 2014-10-02 Table of contents Table of contents 1 Foreword 4 1.1 Notes on the Documentation 4 1.1.1 Liability
EtherCAT Cutting Costs with High-speed Ethernet
EtherCAT Cutting Costs with High-speed Ethernet The real-time Ethernet fieldbus for automati 2 Real-time Ethernet down to the I/O level Low system costs Flexible topology Maximum performance Easy configuration
User manual Compact Web PLC WP240 series IEC-line
User manual Compact Web PLC WP240 series IEC-line update: 09-01-2014 IEC-line by OVERDIGIT overdigit.com 1. General description The WP240 device is a PLC, programmable in IEC61131-3 language using CoDeSys
Installation and Operating instructions for 19 Inch Rack Mount Industrial PC C5102
Installation and Operating instructions for 19 Inch Rack Mount Industrial PC C5102 Version: 1.9 Date: 2014-12-02 Foreword Table of contents 1. 2. 3. 4. Foreword 4 Notes on the Documentation 4 Liability
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
LwLVision-USB 2.0. Installation Guide
LwLVision-USB 2.0 Installation Guide About this manual This manual has been carefully compiled and examined to the state-of-the-art. G&D neither explicitly nor implicitly takes guarantee or responsibility
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
Teleservice via RS232 interface XC100/XC200
User Manual 10/10 MN0500005Z-EN replaces 07/04 AWB74-1490GB Teleservice via RS interface XC100/XC00 All brand and product names are trademarks or registered trademarks of the owner concerned. Emergency
Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11
Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks. The MPU handles the absolute time and
PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version 2.1.0 (2013-11-15)
PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN User Manual Document version 2.1.0 (2013-11-15) Products taken into account Product Name Model Part number PCAN-B10011S IPEH-002041 CANopen
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
Amcrest 960H DVR Quick Start Guide
Amcrest 960H DVR Quick Start Guide Welcome Thank you for purchasing our Amcrest 960H DVR! This quick start guide will help you become familiar with our DVR in a very short time. Before installation and
CANtrol EC Modular Control System Powerful and versatile
Controls CANtrol EC Modular Control System Powerful and versatile CANtrol EC The modular control system Components of CANtrol EC 1 EC1000 Ethernet Controller 2 E-I/O EtherCAT I/O family communicating controlling
1 Technical Description Lokal-200PC
1 Technical Description Lokal-200PC 1.1 Overview laptop with in-built accummulator USB connection correlator box internal power supply laptop (if the device has been supplied by F.A.S.T.) BNC aerial connection
Operating instructions. AS-i Profibus gateway AC1411 / AC1412 7390884/00 04/2014
Operating instructions AS-i Profibus gateway AC1411 / AC1412 7390884/00 04/2014 Contents 1 Preliminary note 4 1.1 Notes on this document 4 1.2 Symbols used 4 2 Safety instructions 4 2.1 General 4 2.2 Installation
SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0
SVC400P/SVC800P 4/8 Camera Live Tracking Vehicle DVR Installation Manual Version 1.0 1. MAIN FEATURES... 2 2. PRODUCT OVERVIEW... 2 3. DIMENSIONS... 4 4. PACKAGE CONTENTS... 5 5. MOUNTING AND ENVORNMENTAL
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB
Product Manual ABB i-bus KNX IP Interface IPS/S 2.1 Intelligent Installation Systems ABB This manual describes the function of the IP Interface IPS/S 2.1 with the application program IP Interface. Subject
EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014
EZmoto V2 Product description Rev. 6 10/01/2014 1 Contents 1. Overview... 3 2. Hardware Interface Description... 3 2.1 Main features of the EZmoto... 3 2.2 Hardware block diagram... 4 2.3 Internal Hardware
Manual. CANcaseXL CANcaseXL log. Version 5.1 English
Manual CANcaseXL CANcaseXL log Version 5.1 English Imprint Vector Informatik GmbH Ingersheimer Straße 24 D-70499 Stuttgart The information and data given in this user manual can be changed without prior
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
R60 USB to CAN interface Manual (1.5 EN)
R60 USB to CAN interface Manual (1.5 EN) General information R60 USB to CAN interface Manual Version 1.5 EN, 02/2010, DOC01586 Copyright 2010 by ; all rights reserved. Eugen-Adolff-Strasse 134, D-71522
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
Hardware Manual RM CANview Ethernet
Hardware Manual RM CANview Ethernet Table of Contents 1 Legal Regulations...3 2 About the Device...4 3 Disposal...4 4 Important Information for Using CANview Ethernet...5 4.1 How to Open the Protection
Infinity C Reference Guide
1 2! Infinity C Reference Guide Table of Contents Components... 1 Hardware Setup... 5 SmartDrive Configuration... 12 Startup... 15 Login... 16 System Configuration... 19 DICOM Setup... 20 Monitoring Status...
Beckhoff onboard SATA-RAID
Installation and operating instructions for Beckhoff onboard SATA-RAID Version: 1.3 Date: 2009-07-24 Table of contents Table of contents 1. 2. 3. 4. 5. 6. 7. General notes 2 Notes on the documentation
Mobile Data Power Model: MDP-25
Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss
SIMATIC S7-300. Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E01094750-01
SIMATIC S7-300 Getting Started for First Time Users Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E01094750-01 Safety Guidelines This manual contains notices you have to observe in order to ensure your personal
Standard diagnostic and configuration interface for Beckhoff Industrial PCs
Keywords Industrial PC Embedded Preventive maintenance Monitoring TwinCAT Diagnostics Configuration MDP Programming interface Interface Standard diagnostic and configuration interface for Beckhoff Industrial
TX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
SCD Server. SCD Server Pro
SCD Server SCD Server Pro SCD Server & SCD Server Pro 9850-000387-01 - Page 1 of 8 SCD Server and SCD Server Pro The SCD Server is a 2U high DMX generator, running the ZerOS Operating System and emulating
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
FB-500A User s Manual
Megapixel Day & Night Fixed Box Network Camera FB-500A User s Manual Quality Service Group Product name: Network Camera (FB-500A Series) Release Date: 2011/7 Manual Revision: V1.0 Web site: Email: www.brickcom.com
UniStream CPU-for-Panel
UniStream CPU-for-Panel Installation Guide USC-P-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for industrial automation. This guide provides basic
mdm-mp3 minidirector with MP3 Player
minidirector with MP3 Player User Manual December 15, 2014 V1.02 Copyright Light O Rama, Inc. 2007, 2008 Table of Contents Introduction... 4 What s in the Box... 4 Hardware Utility Version... 5 Important
Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation
Quick Installation A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding This chapter intends to get your new FuzzyScan scanner working with your existing system within minutes. General instructions
AudioJoG (TM) Pro 8 Connector PIN LABEL LED Connector PIN LABEL LED. Operations Manual 3.5mm & 6.35mm Mono/Stereo Jacks
LED/Connector pin identification table AudioJoG (TM) Pro 8 Connector PIN LABEL LED Connector PIN LABEL LED Operations Manual 3.5mm & 6.35mm Mono/Stereo Jacks 3,4,5 pole XLR Male & Female 3,5 & 8 pole 180
DCS Data and communication server
8 58 PLD.TOWER PLD.RACK VISONIK DCS Data and communication server PLD.TOWER PLD.RACK Data and communication servers (DCS) are used as management stations in building automation and control (BAC). With
Modular I/O system Rugged Modular I/O System Solutions EN-50155 certified for railway applications
The systems and devices of the MODULAR I/O family are the Tecnint HTE solutions for industrial and technological application of automation, acquisition and management that require particularly robustness
OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher
OPERATION MANUAL MV-410RGB Layout Editor Version 2.1- higher Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410RGB Layout
HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: [email protected] NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
M2M 3350 GSM/GPRS Modem User s Manual & Reference Guide Revision 1 June 2007
M2M 3350 GSM/GPRS Modem User s Manual & Reference Guide Revision 1 June 2007 1999-2007 by Laipac Technology, Inc. All rights reserved The Specifications and information regarding the products in this manual
PCAN-ISA. CAN Interface for ISA. User Manual
PCAN-ISA CAN Interface for ISA User Manual Products taken into account Product Name Model Item Number PCAN-ISA Single Channel One CAN channel IPEH-002074 PCAN-ISA Dual Channel Two CAN channels IPEH-002075
PCAN-MicroMod Universal I/O Module with CAN Interface. User Manual. Document version 2.1.0 (2014-01-16)
PCAN-MicroMod Universal I/O Module with CAN Interface User Manual Document version 2.1.0 (2014-01-16) Products taken into account Product Name Part number Model PCAN-MicroMod IPEH-002080 with firmware
WinCON8000-R2/R8. Hardware User s Manual
WinCON8000-R2/R8 Compact Embedded Controller Hardware User s Manual REV 1.1 2004/10/22 1 Warranty All products manufactured by ICP DAS are warranted against defective materials for a period of one year
SAGEM F@st TM 1201/1241 V2
SAGEM F@st TM 1201/1241 V2 Quick Installation Guide 253156400-A_GIR 1201 V2 STD-gb.i1 1 14/10/2008 16:59:35 Contents 1 contents of the pack...2 2 connecting YOUR MODEM...3 2.1 Connecting your router...3
Ultra Thin Client TC-401 TC-402. Users s Guide
Ultra Thin Client TC-401 TC-402 Users s Guide CONTENT 1. OVERVIEW... 3 1.1 HARDWARE SPECIFICATION... 3 1.2 SOFTWARE OVERVIEW... 4 1.3 HARDWARE OVERVIEW...5 1.4 NETWORK CONNECTION... 7 2. INSTALLING THE
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
Documentation. EL31xx. Analog Input Terminals (16 Bit) Version: Date: 5.0 2015-10-29
Documentation Analog Input Terminals (16 Bit) Version: Date: 5.0 2015-10-29 Product overview Analog Input Terminals 1 Product overview Analog Input Terminals EL3101, EL3102, EL3104 [} 13] 1, 2 and 4 channel,
DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual
DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages
HARDWARE MANUAL. BrightSign HD120, HD220, HD1020. BrightSign, LLC. 16795 Lark Ave., Suite 200 Los Gatos, CA 95032 408-852-9263 www.brightsign.
HARDWARE MANUAL BrightSign HD120, HD220, HD1020 BrightSign, LLC. 16795 Lark Ave., Suite 200 Los Gatos, CA 95032 408-852-9263 www.brightsign.biz TABLE OF CONTENTS OVERVIEW... 1 Block Diagram... 2 Ports...
CM500 High Speed Cable Modem User Manual
User Manual February 2015 202-11472-04 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on the label
Communication Unit 560CMU05 Data sheet
RTU560 product line Communication Unit 560CMU05 Data sheet E1 10/100 MB LAN E2 10/100 MB LAN CP1, CP2 RS232C or RS485 Ethernet Controller Ethernet Controller USART Processor bus MPU ELAN520 /Flash Memory
R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement
I/Q Modulation Generator Supplement The following description relates to the Operating Manuals, version 03 of R&S AFQ100A, and version 01 of R&S AFQ100B. It encloses the following topics: LXI features,
Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8
CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps LEDs for display of supply voltage, group and bus errors as well as status and diagnostics Connection
PCAN-USB CAN Interface for USB. User Manual. Document version 2.3.2 (2015-09-03)
PCAN-USB CAN Interface for USB User Manual Document version 2.3.2 (2015-09-03) Products taken into account Product Name Model Part Number PCAN-USB IPEH-002021 PCAN-USB opto-decoupled Galvanic isolation
Quick Start Turning on the Tablet PC for the First Time
User s Manual DL46 Getting Started Congratulations on your purchase of a Tablet PC. The Tablet PC is a fully functional PC with built-in LAN, and wireless connectivity. With your Tablet PC you will be
L5354 ControlNet Communications Interface
L5354 ControlNet Communications Interface Technical Manual HA470733 Issue 2 Copyright SSD Drives Inc 2005 All rights strictly reserved. No part of this document may be stored in a retrieval system, or
4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection
User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
MANUAL PC1000R [email protected]
MANUAL PC1000R [email protected] Features The APart PC1000R is a professional multisource CD/USB/SD card music player, equipped with balanced and unbalanced analog outputs, coaxial and optical digital
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS
MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.
CM400 High Speed Cable Modem User Manual
User Manual July 2015 202-11412-02 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on the label of
Installation Guide. AXIS 2191 Audio Module Sight, Speech and Sound over IP!
Installation Guide AXIS 2191 Audio Module Sight, Speech and Sound over IP! AXIS 2191 Installation Guide Page 1 of 7 The AXIS 2191 Audio Module The AXIS 2191 Audio Module is an add-on device that provides
Vibration Monitoring System Adash 3600
" User's guide Application: Vibration Monitoring System Adash 3600! Vibration diagnostics, monitoring and protective on-line system! On-line vibration monitoring system of engines, fans, pumps, gearboxes,
Industrial Bar Code Scanners
DS6400 Industrial Bar Code Scanners Configuration SW Tool ACR4 technology PackTrack APPLICATIONS Automated warehousing Medium conveyor sorting Reading on forklift trucks Picking systems Automated shop
Versions. Q.station Q.station T. Q.station D. Q.station DT x x
Most important features: Very high data rates up to 100 khz each channel 100 khz at 16 channels, 10 khz at 128 channels 64 Q.bloxx modules connectable Ethernet interface for configuration and data output
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
GSM Interfacing Board
Campus Component Pvt. Ltd. DISCLAIMER Information furnished is believed to be accurate and reliable at the time of publication. However, Campus Component Pvt. Ltd. assumes no responsibility arising from
LDG DTS-4/4R Desktop Coaxial Switch / Remote
LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 [email protected] www.ldgelectronics.com
MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE
DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000
Engineering Tools. Backup & Restore. Data saving and restoring _ Software Manual EN. Ä.N""ä
Engineering Tools Backup & Restore Data saving and restoring _ Software Manual EN Ä.N""ä 13450101 L Contents 1 About this documentation......................................................... 4 1.1 Document
How To Use A Network Card With A Network Box (Ios) On A Microsoft Powerbook 2.5 (I2) (I3) (Io2) And I2 (Io) (Net) (Ipo) (
FACTORY AUTOMATION MANUAL BM100 BACKUP MODULE With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of
Addendum to the Operating Instructions
Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions MOVIMOT with AS-Interface and AC Motor DT/DV Unit Replacement MOVIMOT MM..C -> MM..D with MLK3A
Installation and Operating instructions for. CP70xx Control Panel. Version: 1.6 Date: 2007-10-22
Installation and Operating instructions for CP70xx Control Panel Version: 1.6 Date: 2007-10-22 Table of contents Table of contents 1. 2. 3. 4. 5. 6. General Notes 2 Notes on the documentation 2 Liability
Multi-Protocol decoder 76 200 with Load regulation
Multi-Protocol decoder 76 2 with Load regulation For locomotives with universal motors on digital layouts operating in the DCC and Motorola data format. Features 76 2 Load regulated multi-protocol decoder
How to read this guide
How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information
RN-XV-RD2 Evaluation Board
RN-XV-RD2 Evaluation Board 2012 Roving Networks. All rights reserved. -1.01Version 1.0 9/28/2012 USER MANUAL OVERVIEW This document describes the hardware and software setup for Roving Networks RN-XV-RD2
Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001
Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
Version Date Author Description 1.00 19.07.2010 Jpo First version 1.01 21.12.2010 Jpo FET output descriptions made clearer 1.02 04.02.
+3 # Version Date Author Description 1.00 19.07.2010 Jpo First version 1.01 21.12.2010 Jpo FET output descriptions made clearer 1.02 04.02.2011 Jpo Reset button added 1. Purpose of this user manual...
DK40 Datasheet & Hardware manual Version 2
DK40 Datasheet & Hardware manual Version 2 IPC@CHIP DK40 Evaluation module Beck IPC GmbH http://www.bcl.de page 1 of 11 Table of contents Table of contents... 2 Basic description... 3 Characteristics...
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
2013 Wireless Video Intercom INSTALLATION GUIDE
2013 Wireless Video Intercom INSTALLATION GUIDE INDEX System configuration and wiring VL-SWD501 System Component.. 4 VL-SWD501EX wiring schematic diagram VL-SWD501EX wiring type and length... 5.... 6 Door
LEN s.r.l. Via S. Andrea di Rovereto 33 c.s. 16043 CHIAVARI (GE) Tel. +39 0185 318444 - Fax +39 0185 472835 mailto: [email protected] url: http//www.len.
MA511 General Index 1 INTRODUCTION... 3 1.1 HARDWARE FEATURES:... 4 2 INTERFACE... 5 2.1 KEYBOARD... 6 2.2 POWER ON... 7 2.3 POWER OFF... 7 2.4 DETECTOR CONNECTION... 7 2.5 DETECTOR SUBSTITUTION...7 3
INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description
INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS stam-irs_en 01/11 STAM-IRS is a dedicated server to be used with the STAM-2 monitoring station which enables receiving transmissions sent via telephone
PU-USBX. USB over Ethernet Extender OPERATION MANUAL
PU-USBX USB over Ethernet Extender OPERATION MANUAL Safety Precautions Please read all instructions before attempting to unpack or install or operate this equipment, and before connecting the power supply.
VOICE RECORDING SYSTEM ISDN PRI / BRI
Sense Box VOICE RECORDING SYSTEM ISDN PRI / BRI / Analog SUB-SYSTEM ISDN2, ISDN30 Sense Box USER MANUAL TABLE OF CONTENTS 1. STATUTORY INFORMATION... 3 1.1 SAFETY WARNING... 3 1.2 SAFETY EXTRA LOW VOLTAGE
A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware
A+ Guide to Managing and Maintaining Your PC, 7e Chapter 1 Introducing Hardware Objectives Learn that a computer requires both hardware and software to work Learn about the many different hardware components
