U.S.S. TEXAS (BB-35)
|
|
|
- Marjory Shaw
- 9 years ago
- Views:
Transcription
1 U.S.S. TEXAS (BB-35) OPTION 5 TANK INSPECTION AND REPAIR ASSESSMENT JOSEPH W. LOMBARDI OCEAN TECHNICAL SERVICES, LLC. Marine Surveyor & Consultant 10 Dalton Avenue Gloucester, Massachusetts i
2 JOSEPH W. LOMBARDI Marine Surveyor & Consultant OCEAN TECHNICAL SERVICES, LLC 10 Dalton Avenue, Gloucester, Massachusetts Office (978) Fax (866) Vessel surveyed at: La Porte, Texas Dates of Survey: January 2012 Date of Final Report: February 2013 Vessel Survey Report No Vessel surveyed: Survey commissioned by: U.S.S. TEXAS (BB-35) Texas Parks & Wildlife Battleship TEXAS State Historic Site 3523 Independence Parkway South La Porte, Texas Purpose of survey: Tank Inspection & Repair Assessment Crew on scaffolding painting shell plating at waterline of USS TEXAS in drydock. (NARA & TPWD Collections) ii
3 Table of Contents EXECUTIVE SUMMARY INTRODUCTION STEM TANKAGE COFFERDAM, A-41, Stem to Frame # TRIMMING TANK, A-1, Stem to Frame # GASOLINE TANK, A-2, Frames #5 to # BOILER ROOM # TANK B-2-2-W TANK B-2-1-W TANK B-2-4-W TANK B-2-3-W BOILER ROOMS # 3 & # 4, Frames 60 ½ / B-3, HOLD TANKAGE, Frames 60 ½ B-3-2-W, Port, Reserve Feed Water Tank B-3-1-W, Starboard, Reserve Feed Water Tank B-3-4-W, Port, Reserve Feed Water Tank B-3-3-W, Starboard Reserve Feed Water Tank B-3, INNER BOTTOM TANKAGE, Frames 60 ½ B-3, NAVAL ARCHITECT S COMMENTS ON TANK REPAIRS Suspension of Boilers within P Repair of Floor within B Repair to B-3-4-W Repair to B-3-3-W B-4, HOLD TANKAGE, Frames ½ B-4-2-W, Port, Reserve Feed Water Tank B-4-1-W, Starboard, Reserve Feed Water Tank B-4-4-W, Port, Reserve Feed Water Tank B-4-3-W, Starboard, Reserve Feed Water Tank B-4, INNER BOTTOM TANKAGE, Frames ½ B-4, NAVAL ARCHITECT S COMMENTS ON TANK REPAIRS Repair to B-3-3-W Repair of Floor Within B Repair to B-4-2-W Repair to B-4-1-W INNER BOTTOM TANKAGE, Frames 77 ½ ENGINEROOMS, C-1 & C-2, Frames Engine Supports Engineroom Deck NAVAL ARCHITECT COMMENTS ON ENGINE SUPPORTS INNER BOTTOM, Frames DESCRIPTION EMERGENCY FUEL TANK, C-94F PORT EMERGENCY FUEL TANK, C-95F STARBOARD EMERGENCY FUEL TANK, C-96F PORT EMERGENCY FUEL TANK, C-97F STARBOARD EMERGENCY FUEL TANK, C-98F PORT EMERGENCY FUEL TANK, C-99F STARBOARD KEEL NAVAL ARCHITECT S COMMENTS ON INNER BOTTOM REPAIRS TO iii
4 FRAMES, BULKHEADS & KEEL, Frames INNER BOTTOM TANKAGE, FRAMES AFTER EMERGENCY DIESEL GENERATOR ROOM, D-11, Frames NAVAL ARCHITECT S COMMENTS ON REPAIRS TO AFT EMERGENCY DIESEL GENERATOR ROOM, D-11, Frame VOID SPACE, D-99, Frames NAVAL ARCHITECT S COMMENTS ON REPAIRS TO VOID D-99V, Frames DISCUSSION OF REPAIRS TO AFT END OF SHIP, Frames 122 Aft Perpendicular ND PLATFORM & HOLD, TRIMMING TANK, D-12 ) & STOREROOMS OUT-BOARD OF STEERING ROOM (D-25), Frames NAVAL ARCHITECT S COMMENTS ON REPAIRS TO 2 ND PLATFORM, HOLD, TRIMMING TANK (D-12) & STOREROOMS OUTBOARD OF STEERING RAM ROOM (D-25), Frames ND PLATFORM & HOLD, TRIMMING TANK D-13, STEERING GEAR ROOM D-27, Frames NAVAL ARCHITECT S COMMENTS ON REPAIRS TO 2 ND PLATFORM, HOLD, TRIMMING TANK (D-13) & STEERING RAM ROOM (D-27), Frames nd PLATFORM VOID D-107, FRAMES 137 AFT PERPENDICULAR NAVAL ARCHITECT S COMMENTS ON REPAIRS TO 2 ND PLATFORM VOID D- 107, FRAMES 137 AFT PERPENDICULAR VOIDS D-101, D-102, D-103, FRAMES NAVAL ARCHITECT S COMMENTS ON REPAIRS TO VOIDS D-101, D-102 & D-103, Frames THIRD DECK, CPO QUARTERS D-111, CPO MESS ROOM D-112, CPO PANTRY D NAVAL ARCHITECT S COMMENTS ON REPAIRS TO THIRD DECK, CPO QUARTERS D-111, CPO MESS ROOM D-112, CPO PANTRY D SUMMARY APPENDIX iv
5 List of Figures Figure 1: Structurally Deficient and Critical Areas of Vessel (Demarcated within Red Lines)... 2 Figure 2: Stem Tankage... 4 Figure 3: Stem Aprons, Looking Down in A Figure 4: Keel and Bilges at Forward End of A Figure 5: Keel & floors in A Figure 6: Standing Water on Side Shell Aprons Due to Condensation in A Figure 7: Heavy Rust/scale and Condensation on Side Shell Apron in A Figure 8: Top of Gasoline Storage Tanks within A Figure 9: Looking Down to Floor at Aft Bulkhead in A Figure 10: Frontal View of Boilers in B-2 Fireroom, Looking Aft... 8 Figure 11: Base Foundation and Intact Floor of Port Side Boiler in B-2 Fireroom... 8 Figure 12: Base Foundation and Intact Floor of Starboard Side Boiler in B-2 Fireroom... 9 Figure 13: B-2-2-W. Views of Tank Showing Relatively Good Structural Condition of Scantlings... 9 Figure 14: B-2-1-W. Holed Transverse Frame within Tank Figure 15: B-2-1-W. Typical Transverse Frame within Tank, Showing Hatch to Inner Bottom Figure 16: B-2-4-W. Boiler Foundation Knee with Longitudinal Frame Figure 17: B-2-4-W. Typical Longitudinal Frame within Tank Figure 18: B-2-3-W. Typical Longitudinal Frame within Tank, Showing Boiler Foundation Figure 19: B-2-3-W. Delaminated Steel Scantling, Typical for Most Frames within this Tank Figure 20: Detail of I-beam and Threaded Rod for Boiler Supports Figure 21: View of Sides of Boilers showing I-beams, Wire and Nylon Straps for B-3 & B-4 Firerooms. 14 Figure 22: Shaded area Yellow within B-3 Signifying Areas where Floors Need Replacement Figure 23: Wasted Floor Under Rear of Port Side Boiler in B Figure 24: Shaded Area Yellow within B-4 Signifying Areas where Floors Need Replacement Figure 25: Wasted Floor Under Rear of Port Side Boiler in B Figure 26: B-3 Hold Tankage Figure 27: Typical Condition within B-3-2-W Tank Figure 28: Typical Condition within B-3-2-W Tank Figure 29: Typical Condition within B-3-2-W Tank Figure 30: Typical Condition of Transverse frames within B-3-1-W Figure 31: Forward Longitudinal frame within B-3-1-W Figure 32: Forward Transverse and Boiler Support Frame within B-3-4-W Figure 33: Aft Transverse and Boiler Support Frame within B-3-4-W Figure 34: Forward Transverse and Boiler Support Frame within B-3-3-W Figure 35: Transverse and Longitudinal Frames within B-3-3-W Figure 37: B-4 Hold Tankage Figure 38: Typical Condition of Boiler Support within B-4-2-W Figure 39: Typical Condition of De-laminated and Holed Frames within B-4-2-W Figure 40: Typical Condition within B-4-2-W Figure 41: Typical Condition with Holed Plating on Overhead within B-4-1-W Figure 42: Typical Condition within B-4-1-W Figure 43: Typical Condition within B-4-4-W Figure 44: Typical Condition within B-4-4-W Figure 45: Typical Condition of B-4-3-W Figure 46: Typical Condition of B-4-3-W Figure 47: Enginerooms C-1 and C-2 within Hold Spaces Figure 48: Side View of Main Engine with Support Wires; Typical for Both Main Engines Figure 49: Starboard Main Engine, looking Forward showing Side Supports and Overhead Wires Figure 50: Inner Bottom Tankage, Frames Figure 51: Detail Sampling of Flat Plate of Keel Figure 51A: Detail Sampling of End on View of Keel showing Diagonal Support Brackets v
6 List of Figures (cont.) Figure 52: Aft Emergency Diesel Generator Room Figure 53: Forward Bulkhead in Aft Emergency Diesel Generator Room at Frame # 115, showing Plate Replacement Figure 54: Aft Bulkhead in Aft Emergency Diesel Generator Room at Frame #120, showing Plate Replacement Figure 55: Side View of Aft Emergency Diesel Generator Suspended from Overhead Figure 56: Frontal View of Aft Emergency Diesel Generator Suspended from Overhead Figure 57: Aft side of Emergency Diesel Generator in D Figure 58: Void D-99V, Inner Bottom Tankage Figure 59: Detail Sampling of Flat Plate of Keel within D-99V from Frames Figure 60: Detail of Stern Repair Area Figure 61: Trimming Tank, D Figure 62: Typical Main Transverse and Longitudinal Frame in D-12 Trimming Tank Figure 63: Wasted Longitudinal and Transverse Frames to Starboard between Frame Notice Seepage and Run-off from Leaking Shell Plating in D-12 Trimming Tank Figure 64: Plate Replacement at Transverse Bulkhead at Frame # Figure 65: Transverse Frames in D-26P, D-26S and D-12 Trimming Tank Figure 66: Transverse frames 127 in D-26P, D-26S and D-12 Trimming Tank Figure 67: Transverse frames 128 in D-26P, D-26S and D-12 Trimming Tank Figure 68: Transverse Frame 129 and Bulkhead in D-26P, D-26S and D-12 Trimming Tank Figure 69: Base of Centerline Wasted Stanchion Resting on Wasted Pedestal over Keel in D-12 Trimming Tank Figure 70: D-13 Trimming Tank, looking Forward to Bulkhead at Frame Figure 71: D-13 Trimming Tank, looking Aft to Stern Casting Figure 72: Typical Base of Transverse Frame within D Figure 73: Heavy Steering Rams and Rudder Post in D Figure 74: Badly Corroded Scantlings Aft of Rudder Post Figure 75: Upper Portion of D-107, Showing Heavily Corroded Scantlings Figure 76: Stern Casting, Showing Daylight Through Wasted and Holed Shell Plating on Centerline Above Waterline Figure 77: Heavily Wasted Transverse Frame at Base of Compartment Figure 78: Building the Void Spaces D-101, D-102 & D Figure 79: D-101 Looking Forward to Port Figure 80: D-102 Looking Across Turtle back to Starboard Showing Wasted Vertical Stanchions Figure 81: Wasted Vertical Stanchion. Typical throughout D-101, D-102 & D Figure 82: Wasted Vertical Stanchion Figure 83: Detail of Voids D-101, D-102, D Figure 84: Bird s Eye View of Voids D-101, D-102 & D Figure 85: Bird s Eye View of D-111, D-112 & D Figure 86: Looking to Starboard in D Figure 87: Wasted Stanchion Base in D Figure 88: D-112 CPO Mess Space Figure 89: Wasted Stanchion Base in D Figure 90: Looking to Starboard in D Figure 91: Looking to Aft in D vi
7 U.S.S. TEXAS, Tank Inspection & Repair Estimates EXECUTIVE SUMMARY This report presents an assessment of the present condition of the centerline tankage as obtained from a thorough and detailed inspection carried out in January Critical problem areas have been identified as those that merit immediate consideration and repair before the re-floating/super-flooding of the vessel through dredging and the preparation for the Option 5 berthing configuration. The terms Option 5 and Option 6 refer to berthing configurations considered subsequent to Options 1 through 4 considered in the Dry Berth of the Battleship Texas State Historic Site Phase I: Conceptual Design Report (AECOM, September 2011). Option 5 is a berthing configuration that grounds the ship in the dry, directly on the sand within her current berth. Option 6 is an option that includes only selected ship repairs, and the leaves the ship in place in her wet berth with no changes to the berth itself. It is quite apparent that repairs will be required for the vessel s frames, floors, bulkheads, stanchions and shell plating after Frame # 60. These concerns/conclusions were raised in the Phase I Hull Survey; this report will characterize the scope and estimated costs for those repairs. This report covers only the centerline tanks and spaces at the stem of the vessel and from Frame # 60 to the stern; other outboard tankage within the original shell of the ship has not been inspected, nor have the extensive blister tank system outboard of the original shell of the ship been inspected. Whether Option 5 or Option 6 berthing alternatives is ultimately chosen, the end game is the same as the vessel will be required to float on her own bottom throughout. No estimate of scope and cost for repairs can be estimated outside of the inspected areas. The reporting for this report will commence at the stem for the forepeak area, proceeding aft to the B-2 to B-4 boiler rooms and inner bottom/hold tankage, thence to the pair of enginerooms and associated inner bottom tankage, proceeding aft to tankage to vicinity of Frame # 115 (After Emergency Diesel Room). The remaining structure aft of Frame # 122 to the stern will be reported starting from the keel up to the bottom of the 2 nd Deck. A description of repair methodology within each compartment, required remediation within each space, materials required, and estimated costs for repairs are included within the body of this report. Mr. Jerry Possehl, N.A. has added comments on the repairs as required within each section of the report. A separate estimate of total project costs is provided within the Appendix. The estimated total cost for repairs within this cover is $21,155, Unless these issues are addressed satisfactorily before the vessel is re-floated, there is significant risk in causing serious and irreparable damage to the vessel. 1
8 Figure 1: Structurally Deficient and Critical Areas of Vessel (Demarcated Within Red Lines) 2
9 U.S.S. TEXAS, Tank Inspection & Repair Estimates 1. INTRODUCTION This tank inspection survey of the centerline tankage of the battleship U.S.S. TEXAS was conconducted (January 2012) where she lay (aground within the slip bottom; afloat only on high water events) at the San Jacinto State Battleground Park within her side slip/berth in the Houston Ship Channel. The purpose of this tank inspection was to ascertain the scope and estimated costs for repairs needed for the vessel under Option 5 scenarios. The surveyor was tasked with identifying issues of structure, internal tankage and the present/future issues facing the ship from a material condition perspective. The surveyor was also tasked with recommending general alterations or improvements needed within this tankage to properly support overhead components (boilers, main engines, structure, etc.) on this vessel to allow a safe floating and aground condition when the ship finally comes to rest in her current berth. Inspections of the outboard blister tank appendages were not a part of this survey, nor were the balance of tankage outside of the centerline tanks. The ship s staff assisted greatly in this task of opening tank covers and hatches where they could safely enter spaces. Spaces not inspected are not noted within this report. Entry into fuel and/or ballast tanks was subject to air quality requirements under 29 CFR Code of Federal Regulation requirements and this was done with inspections carried out by a Marine Chemist. Where tank inspections were not possible, visual inspections from tank manhole covers was accomplished with photographs being taken by ISHOT 550 HD camera. The underwater appendage was not observed. The inspection of this vessel started from forward to aft, and top to bottom and shall be described following that same course here in the narrative, except after Frame # 122 where extensive repairs dictate that work commence at the keel and work up through the structure. The Code of Federal Regulations (CFR), American Boat & Yacht Council (ABYC), International Marine Organization (IMO), National Fire Protection Association (NFPA), and the Society of Naval Architects and Marine Engineers (SNAME) are utilized in compiling this report. Individual reference to subchapters of the above is not made within the body of this report. Other sources include the 'U.S. Navy Towing Manual', 'Manual on Ship Construction, George C. Manning: Van Nostrand Co., and 'Standards For Steel Hulled Vessels', American Bureau of Shipping, 'Stability and Trim for the Ship's Officer' by William E. George, Cornell Maritime Press and 'Ship Design and Construction' by the Society of Naval Architects and Marine Engineers. 3
10 2. STEM TANKAGE Figure 2: Stem Tankage 2.1 COFFERDAM, A-41, Stem to Frame 5 Space is heavily corroded, but not structurally deficient. Peeling paint and rust/scale abound. This space requires no structural repairs or modifications. Stem casting intact and in good repair on both flats. Stem aprons heavily corroded at 30-40% loss of structural integrity. Transverse framing showing 30%+ loss of integrity. Aft bulkhead intact. No evidence of leakage. Figure 3: Stem Aprons, Looking Down in A-41. 4
11 2. STEM TANKAGE (cont.) 2.2 Trimming Tank, A-1, Stem to Frame #5 Space is heavily corroded, but not structurally deficient. Peeling paint and rust/scale abound. This space requires no structural repairs or modifications. Stem aprons heavily corroded at 50%+ loss of structural integrity. Upper transverse framing showing 30%+ loss of integrity; lower transverse framing showing 40%+ loss of integrity. Aft bulkhead intact with 30-40% wastage. Keel showing 30 40% wastage in areas, but intact. Standing water 2-3 with heavy muck/rust/scale present. Condensation standing on horizontal aprons and shelves causing heavy corrosion. Figure 4: Keel and Bilges at Forward End of A-41 Figure 5: Keel and Floors in A-41 5
12 2. STEM TANKAGE (cont.) Figure 6: Standing Water on Side Shell Aprons Due to Condensation in A-41 Figure 7: Heavy Rust/scale, and Condensation on Side Shell Apron in A-41 6
13 2. STEM TANKAGE (cont.) 2.3 GASOLINE TANK, A-2, Frames #5 to #9 Space is heavily corroded, but not structurally deficient. Peeling paint and rust/scale abound. This space requires no structural repairs or modifications. Side shell aprons heavily corroded at 50%+ loss of structural integrity. Upper transverse framing showing 30%+ loss of integrity; lower transverse framing showing 40%+ loss of integrity. Aft bulkhead intact with 30-40% wastage. Keel showing 30 40% wastage in areas, but intact. Standing water 2-3 with heavy muck/rust/scale present. Condensation standing on horizontal aprons and shelves causing heavy corrosion. Figure 8: Top of Gasoline Storage Tanks within A-2 Figure 9: Looking Down to Floor at Aft Bulkhead in A-2 7
14 3. BOILER ROOM #2 Figure 10: Frontal View of Boilers in B-2 Fireroom, Looking Aft Material condition of both boilers show them to be in good repair. Bases of both boiler units are intact with structural foundations in good repair with no repairs required. The main floor over the Hold Tankage is intact with no repairs required. Bulkheads and vertical supports intact and in good condition. Figure 11: Base Foundation and Intact Floor of Port Side Boiler in B-2 Fireroom 8
15 3. BOILER ROOM #2 (cont.) Figure 12: Base Foundation and Intact Floor of Starboard Side Boiler in B-2 Fireroom 3.1 TANK B-2-2-W (port, Frames 52-56) Not previously inspected under the Option 1 Survey, this tank space with three transverse frames and two longitudinal frames is directly under boiler room fuel manifolds and miscellaneous equipment; tank components are in good structural condition with no repairs required at this time. Both transverse and longitudinal support frames are intact with minimal plate loss of 20 40% with minimal deflection of steel plate. The floor of this tankage is heavily rusted/scaled, but with no standing water present. Forward bulkhead intact showing 20-30% plate loss and the aft bulkhead intact with 30-40% plate loss with rust/scale present. Vertical scantlings on both fore and aft and outboard bulkheads intact. Centerline keel plate shows plate loss of 20-40% in spots, but is not in need of repair at this time. Evidence of previous long term standing water. Figure 13: B-2-2-W. Views of Tank Showing Relatively Good Structural Condition of Scantlings 9
16 3. BOILER ROOM #2 (cont.) 3.2 TANK B-2-1-W (stbd., Frames 52-56) Not previously inspected under the Option 1 Survey, this tank space with three transverse frames and two longitudinal frames is directly under both boiler room fuel manifolds and miscellaneous components; tank components are in good structural condition with no repairs required at this time. Both transverse and longitudinal support frames are intact with plate loss in areas averaging 20 40% with minimal deflection of steel plate. The transverse and longitudinal frames in this compartment have areas of swiss cheese (holed plating); it is not considered a threat for the immediate period (10-15 years) given the structural condition of adjacent scantlings, the strength of the floor above and the foundations for the boilers. The floor of this tankage is heavily rusted/scaled with greater than 30-50% wastage, but with no standing water present. Forward bulkhead intact showing 30-40% plate loss and the aft bulkhead intact with 30-40% plate loss with rust/scale present. Vertical scantlings on both fore and aft and outboard bulkheads intact. Centerline keel plate shows plate loss of 50% in areas of deep pitting, but is not in need of repair at this time. Figure 14: B-2-1-W. Holed Transverse Frame within Tank Figure 15: B-2-1-W. Typical Transverse Frame within Tank, Showing Hatch to Inner Bottom 10
17 3. BOILER ROOM #2 (cont.) 3.3 B-2-4-W, (PORT, Frames ½) Not previously inspected under the Option 1 Survey, this tank space with four transverse frames and two longitudinal frames is directly under the port boiler; tank components are in good structural condition with no repairs required at this time. Both transverse and longitudinal support frames are intact with plate loss in areas averaging 30 50% with minimal deflection of steel plate. Wastage of the boiler foundation is 40 60%. The floor of this tankage is heavily rusted/scaled with greater than 30-50% wastage, but with no standing water present. Forward bulkhead intact showing 30-40% plate loss and the aft bulkhead intact with 30-40% plate loss with rust/scale present. Vertical scantlings on both fore and aft and outboard bulkheads intact. Centerline keel plate shows plate loss of 50% with keelson knees showing 50 70% loss in areas of deep pitting, but is not in need of repair at this time. Figure 16: B-2-4-W. Boiler Foundation Knee with Longitudinal Frame Figure 17: B-2-4-W. Typical Longitudinal Frame within Tank 11
18 3. BOILER ROOM #2 (cont.) 3.4 B-2-3-W, (STBD, Frames ½) Not previously inspected under the Option 1 Survey, this tank space with four transverse frames and two longitudinal frames is directly under the starboard boiler; tank components are in fair - good structural condition with no repairs required at this time. Both transverse and longitudinal support frames are intact with plate loss in areas averaging 30 60% with minimal deflection of steel plate; steel plate delaminating on both sides equally. The floor of this tankage is heavily rusted/scaled with greater than 30-50% wastage, but with no standing water present. Forward bulkhead intact showing 30-40% plate loss and the aft bulkhead intact with 30-40% plate loss with rust/scale present. Vertical scantlings on both fore and aft and outboard bulkheads intact. Centerline keel plate shows plate loss of 50% in areas of deep pitting with knees showing 50%+ loss in aft area of tank, but is not in need of repair at this time. Figure 18: B-2-3-W. Typical Longitudinal Frame within Tank, Showing Boiler Foundation Figure 19: B-2-3-W. Delaminated Steel Scantling, Typical for Most Frames within this Tank 12
19 4. BOILER ROOMS #3 & #4, Frames 60 ½ /2 Material condition of boilers in both firerooms show them to be in fair repair with base plates and Hold Tankage framing rotting away. Bases of both boiler units are somewhat intact with structural foundations in good repair with no repairs required. The main floors over the Hold Tankage in both Firerooms is holed throughout with repairs required. Bulkheads and vertical supports for both firerooms are intact and in fair condition forward and aft. The condition of both boiler room floors and the condition of support frames within the Hold Tankage beneath the boilers mandates that support of the pair of boilers each in B-3 and B-4 Firerooms; this becomes necessary while the floors and Hold Tankage are rebuilt. The support for the boilers can be achieved by suspending them from the armor deck above. A possible approach would be to utilize steel cable fastened to three 24 wide x 30 long double, 2 ply nylon straps per boiler (for supporting the underneath of the boilers) thence to the overhead deck where sistered 10 x 60 I-beams could rest on the deck with 1.25 x 7 threaded rod attached to the cable ends. The cable ends would be attached to 1.25 bright wire, uncoated, fiber core (FC) wire rope improved plow steel (IPC) with a breaking load of 129,200 lbs down to the nylon straps. The threaded rod could be tensioned to just take the load of the boiler off of the sub-structure allowing repairs to be made in safety. It is estimated that using hardware of this size would result in a safety factor of four (4) and could be tested with dial indicators for working loads; anticipate three straps per boiler. Section 106 remediation to put this back to original would require removal of the support gear and welding the circular holes in the armor deck back to original. For the purposes of cost estimating, the size of the hardware used to suspend the boilers is approximated. The final method of removing the load of the boilers from the structure beneath will require design by a licensed engineer. The drawing below pertains to the end on view of the I-beam resting on the armored deck over the four boilers in B-3 & B-4 Firerooms. Figure 20: Detail of I-beam and Threaded Rod for Boiler Supports (Hardware sizes estimated) 4. BOILER ROOMS #3 & #4, Frames 60 ½ /2 (cont.) 13
20 Figure 21: View of Sides of Boilers showing I-beams, Wire and Nylon Straps for B-3 & B-4 Firerooms The boiler room deck is perforated in many areas and needs to be replaced where it is holed. This will involve the mapping and removal of the steel grating and associated piping beneath to allow access to the deck. The removal of the deck, particularly beneath the boilers will allow steel plate to be inserted into the Hold tankage space to repair both longitudinal and transverse frame plating. Other areas remote from where the overhead deck is to be repaired will require cutting/burning into those tanks below to affect repairs beneath the boilers; these cuts can be reversed by re-installing the cut-out deck plating. Remediation of 4 on either side of a cut/burn areas will be required as per 29 CFR for lead paint issues. Asbestos remediation will be required for friable lagging left on the floors of the boiler rooms and for dust in bilge spaces. Piping may require oil remediation as needed. Once the tankage below has been repaired, the deck can be repair/replaced as needed. Each Boiler Room has approximately 1,632 square feet of floor space. B-3 Boiler Room will require 800 square feet of new ½ A-36 mild steel deck plating, primarily under both boilers and in other scattered areas of the space. B-4 Boiler Room will require 800 square feet of new ½ A-36 mild steel deck plating, primarily under both boilers and in other scattered areas of the space. Deck Replacement in B-3 & B-4 Boiler Rooms Tasking: Remediation of asbestos as needed in Drying and Boiler Rooms. Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR Crop out and replace 1,600 sq. ft of ½ A-36 steel deck plate as needed. Replace stanchions and deck grating.. Prime all new work with two coats of INTERNATIONAL 300V epoxy primer. 4. BOILER ROOMS #3 & #4, Frames 60 ½ /2 (cont.) 14
21 Figure 22: Shaded Area in Yellow within B-3 Signifying Areas where Floors Need Replacement Figure 23: Wasted Floor Under Rear of Port Side Boiler in B-3 4. BOILER ROOMS #3 & #4, Frames 60 ½ /2 (cont.) 15
22 Figure 24: Shaded Area in Yellow within B-4 Signifying Areas where Floors Need Replacement Figure 25: Wasted Floor Under Rear of Port Side Boiler in B-4 5. B-3, HOLD TANKAGE, Frames 60 ½
23 Figure 26: B-3 Hold Tankage 5.1 B-3-2-W, Port, Reserve Water Feed Tank Not previously inspected under the Option 1 Survey, this tank space with four transverse frames and two longitudinal frames is directly under both boiler room fuel manifolds and miscellaneous components; tank components are in fair/good structural condition with no repairs required at this time. Both transverse and longitudinal support frames are intact with plate loss in areas averaging 40 50%; transverses deflected 1 +. The floor of this tankage is heavily rusted/scaled with greater than 30-50% wastage. Forward bulkhead intact showing 30-40% plate loss and the aft bulkhead intact with 40-50% plate loss with heavy rust/scale present. Vertical scantlings on both fore and aft and outboard bulkheads intact. Centerline keel plate shows plate loss of 50% in areas of deep pitting, but is not in need of repair at this time. Compartment is dry. Figure 27: Typical Condition within B-3-2-W Tank 5. B-3, HOLD TANKAGE, Frames 60 ½ - 69 (cont.) 17
24 5.1 B-3-2-W, Port, Reserve Water Feed Tank (cont.) Figure 28: Typical Condition within B-3-2-W Tank Figure 29: Typical Condition within B-3-2-W Tank 5. B-3, HOLD TANKAGE, Frames 60 ½ - 69 (cont.) 18
25 5.2 B-3-1-W, Starboard, Reserve Feed Water Tank Not previously inspected under the Option 1 Survey, this tank space with four transverse frames and two longitudinal frames is directly under both boiler room fuel manifolds and miscellaneous components; tank components are in fair/good structural condition with no repairs required at this time. Both transverse and longitudinal support frames are intact with plate loss in areas averaging 30 40% with minimal deflection of steel plate. The floor of this tankage is heavily rusted/scaled with greater than 30-50% wastage, but with no standing water present. Forward bulkhead intact showing 30-40% plate loss and the aft bulkhead intact with 40-50% plate loss with heavy rust/scale present. Vertical scantlings on both fore and aft and outboard bulkheads intact. Centerline keel plate shows plate loss of 40% in areas of deep pitting, but is not in need of repair at this time. Figure 30: Typical Condition of Transverse Frames within B-3-1-W Figure 31: Forward Longitudinal Frame within B-3-1-W 5. B-3, HOLD TANKAGE, Frames 60 ½ - 69 (cont.) 19
26 5.3 B-3-4-W, Port, Reserve Feed Water Tank Not previously inspected under the Option 1 Survey, this tank space with three transverse frames and two longitudinal frames is directly under the port boiler; tank transverse and longitudinal frames require extensive rebuilding and are in poor/fair structural condition with repairs required at this time. Both transverse and longitudinal support frames have plate loss in all areas averaging 50 70% with deflecttion of steel plate. The floor of this tankage is heavily rusted/scaled with greater than 30-50% wastage, but with no standing water present. Forward bulkhead intact showing 40-50% plate loss and the aft bulkhead intact with 40-50% plate loss with heavy rust/scale present. Vertical scantlings on both fore and aft and outboard bulkheads intact. Centerline keel plate shows plate loss of 40% in areas of deep pitting, but is not in need of repair at this time. Tank is sized 16 long x 24 wide. Tank repair methodology in B-3 requires that both boilers be supported as previously discussed in #4, The boiler room deck is perforated in many areas and needs to be replaced where it is holed. This will involve the mapping and removal of the steel grating and associated piping beneath to allow access to the deck. The removal of the deck, particularly beneath the boiler will allow steel plate to be inserted into the Hold tankage space to repair both longitudinal and transverse frame plating. Other areas remote from where the overhead deck is to be repaired will require cutting/burning into those tanks below to affect repairs beneath the boilers; these cuts can be reversed by re-installing the cut-out deck plating. Tasking for B-3-4-W Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR Crop and replace longitudinal plating (1/2 x 16L x 4 H) on #1 longitudinal,. 64 sq. ft x ½ Crop and replace longitudinal plating (1/2 x 16 L x 4 H) on #2 longitudinal. 64 sq. ft x ½ Crop and replace transverse plating (3/8 x 24 L x 4 H on # 1 transverse 96 sq. ft x 3/8 Crop and replace transverse plating (3/8 x 24 L x 4 H on # 2 transverse 96 sq. ft x 3/8 Crop and replace transverse plating (3/8 x 24 L x 4 H on # 3 transverse 96 sq. ft x 3/8 Replace four 1/2 plating knees for boiler foundations. 40 sq. ft x 3/8 Replace two 1/2 x 4 x 10 x 24 channel beams for boiler foundations. Prime all new work with two coats of INTERNATIONAL 300V epoxy primer. Once the tankage below has been repaired, the deck can be repair/replaced as needed. 5. B-3, HOLD TANKAGE, Frames 60 ½ - 69 (cont.) 20
27 5.3 B-3-4-W, Port, Reserve Feed Water Tank (cont.) Figure 32: Forward Transverse and Boiler Support Frame within B-3-4-W Figure 33: Aft Transverse and Boiler Support Frame within B-3-4-W 5. B-3, HOLD TANKAGE, Frames 60 ½ - 69 (cont.) 21
28 5.4 B-3-3-W, Starboard, Reserve Feed Water Tank Not previously inspected under the Option 1 Survey, this tank space with three transverse frames and two longitudinal frames is directly under the starboard boiler; tank transverse and longitudinal frames require extensive rebuilding and are in poor/fair structural condition with repairs required at this time. Both transverse and longitudinal support frames have plate loss in all areas averaging 50 70% with deflecttion of steel plate. The floor of this tankage is heavily rusted/scaled with greater than 30-50% wastage, but with no standing water present. Forward bulkhead intact showing 40-50% plate loss and the aft bulkhead intact with 40-50% plate loss with heavy rust/scale present. Vertical scantlings on both fore and aft and outboard bulkheads intact. Centerline keel plate shows plate loss of 40% in areas of deep pitting, but is not in need of repair at this time.. Tank is sized 16 long x 24 wide. Tank repair methodology in B-3 requires that both boilers be supported as previously discussed in #4, The boiler room deck is perforated in many areas and needs to be replaced where it is holed. This will involve the mapping and removal of the steel grating and associated piping beneath to allow access to the deck. The removal of the deck, particularly beneath the boiler will allow steel plate to be inserted into the Hold Tankage spaces to repair both longitudinal and transverse frame plating. Other areas remote from where the overhead deck is to be repaired will require cutting/burning into those tanks below to affect repairs beneath the boilers; these cuts can be reversed by re-installing the cut-out deck plating. Tasking for B-3-3-W Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR Crop and replace longitudinal plating (1/2 x 16L x 4 H) on #1 longitudinal,. 64 sq. ft x ½ Crop and replace longitudinal plating (1/2 x 16 L x 4 H) on #2 longitudinal. 64 sq. ft x ½ Crop and replace transverse plating (3/8 x 24 L x 4 H on # 1 transverse 96 sq. ft x 3/8 Crop and replace transverse plating (3/8 x 24 L x 4 H on # 2 transverse 96 sq. ft x 3/8 Crop and replace transverse plating (3/8 x 24 L x 4 H on # 3 transverse 96 sq. ft x 3/8 Replace four 1/2 plating knees for boiler foundations. 40 sq. ft x 3/8 Replace two 1/2 x 4 x 10 x 24 channel beams for boiler foundations. Prime all new work with two coats of INTERNATIONAL 300V epoxy primer. Once the tankage below has been repaired, the deck can be repair/replaced as needed. 5. B-3, HOLD TANKAGE, Frames 60 ½ - 69 (cont.) 22
29 5.4 B-3-3-W, Starboard, Reserve Feed Water Tank (cont.) Figure 34: Forward Transverse and Boiler Support Frame within B-3-3-W Figure 35: Transverse and Longitudinal Frames within B-3-3-W 6. B-3, INNER BOTTOM TANKAGE, Frames 60 ½
30 Tankage within the Inner Bottom (B-90W, B-91W, B-92W & B-93W) will not be repaired under Option B-3, NAVAL ARCHITECT S COMMENTS ON TANK REPAIRS 7.1 SUSPENSION OF BOILERS WITHIN B-3 Suspension of the boilers by the means proposed will replace the existing rotting foundations with significantly stronger material which is substantially indestructible. Suspension of the boilers will move the point of support of these large weights from the bottom structure to the decks above. Based on the location of the boiler spaces between the forward and after turrets and barbettes means the ship will normally be in a hogging condition and the decks overhead will be in tension. Suspending the boilers would reduce the stresses in the deck, although the positive effects would be small. 7.2 REPAIR OF FLOOR WITHIN B-3 Replacement of rusted and holed deck plating with solid plates would increase the strength of the lower hull in the midship area. Although the stresses would be relatively low in the static condition, they will increase as the ship lands on the proposed sand bed. Although the ship should land at the bow first, the midship section will see varying stresses with the possibility of a rip in the lower plates introducing water into the boiler rooms. 7.3 REPAIR TO B-3-4-W Replacement of weakened structure in the Port RFW tank will add stiffening to the structure under the boiler room deck. This will strengthen the lower flange of the midship section of the main hull girder and reduce the chance of failure while the ship waits on Option 5 and during the bottoming. 7.4 REPAIR TO B-3-3-W Replacement of weakened structure in the Starboard RFW tank will add stiffening to the structure under the boiler room deck. This will strengthen the lower flange of the midship section of the main hull girder and reduce the chance of failure while the ship waits on Option 5 and during the bottoming. 8. B-4, HOLD TANKAGE, Frames ½ 24
31 Figure 37: B-4 Hold Tankage 8.1 B-4-2-W, PORT RESERVE FEED WATER TANK Not previously inspected under the Option 1 Survey, this tank space with three transverse frames and two longitudinal frames is directly under the port boiler; tank transverse and longitudinal frames require extensive rebuilding and are in poor/fair structural condition with repairs required at this time. Both transverse and longitudinal support frames have plate loss in all areas averaging 50 70% + with deflecttion of steel plate. The floor of this tankage is heavily rusted/scaled with greater than 30-50%+ wastage, but with no standing water present. Forward bulkhead intact showing 40-50% plate loss and the aft bulkhead intact with 40-50% plate loss with heavy rust/scale present. Vertical scantlings on both fore and aft and outboard bulkheads intact. Centerline keel plate shows plate loss of 40% in areas of deep pitting, but is not in need of repair at this time.. Tank is sized 16 long x 24 wide. Tank repair methodology in B-4 requires that both boilers be supported as previously discussed in #4, The boiler room deck is perforated in many areas and needs to be replaced where it is holed. This will involve the mapping and removal of the steel grating and associated piping beneath to allow access to the deck. The removal of the deck, particularly beneath the boiler will allow steel plate to be inserted into the Hold tankage space to repair both longitudinal and transverse frame plating. Other areas remote from where the overhead deck is to be repaired will require cutting/burning into those tanks below to affect repairs beneath the boilers; these cuts can be reversed by re-installing the cut-out deck plating. Tasking for B-4-2-W Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR 8. B-4, HOLD TANKAGE, Frames ½ (cont.) 25
32 8.1 B-4-2-W, PORT RESERVE FEED WATER TANK (cont.) Crop and replace longitudinal plating (1/2 x 16L x 4 H) on #1 longitudinal,. 64 sq. ft x ½ Crop and replace longitudinal plating (1/2 x 16 L x 4 H) on #2 longitudinal. 64 sq. ft x ½ Crop and replace transverse plating (3/8 x 24 L x 4 H on # 1 transverse 96 sq. ft x 3/8 Crop and replace transverse plating (3/8 x 24 L x 4 H on # 2 transverse 96 sq. ft x 3/8 Crop and replace transverse plating (3/8 x 24 L x 4 H on # 3 transverse 96 sq. ft x 3/8 Replace four 1/2 plating knees for boiler foundations. 40 sq. ft x 3/8 Replace two 1/2 x 4 x 10 x 24 channel beams for boiler foundations. Prime all new work with two coats of INTERNATIONAL 300V epoxy primer. Once the tankage below has been repaired, the deck can be repair/replaced as needed. Figure 38: Typical Condition of Boiler Support within B-4-2-W 8. B-4, HOLD TANKAGE, Frames ½ (cont.) 26
33 8.1 B-4-2-W, PORT RESERVE FEED WATER TANK (cont.) Figure 39: Typical Condition of De-laminated and Holed Frames within B-4-2-W Figure 40: Typical Condition within B-4-2-W 8. B-4, HOLD TANKAGE, Frames ½ (cont.) 27
34 8.2 B-4-1-W, STARBOARD, RESERVE FEED WATER TANK Not previously inspected under the Option 1 Survey, this tank space with three transverse frames and two longitudinal frames is directly under the port boiler; tank transverse and longitudinal frames require extensive rebuilding and are in poor/fair structural condition with repairs required at this time. Both transverse and longitudinal support frames have plate loss in all areas averaging 50 70% + with deflecttion of steel plate. The floor of this tankage is heavily rusted/scaled with greater than 30-50%+ wastage, but with no standing water present. Forward bulkhead intact showing 40-50% plate loss and the aft bulkhead intact with 40-50% plate loss with heavy rust/scale present. Vertical scantlings on both fore and aft and outboard bulkheads intact. Centerline keel plate shows plate loss of 40% in areas of deep pitting, but is not in need of repair at this time.. Tank is sized 16 long x 24 wide. Tank repair methodology in B-4 requires that both boilers be supported as previously discussed in #4, The boiler room deck is perforated in many areas and needs to be replaced where it is holed. This will involve the mapping and removal of the steel grating and associated piping beneath to allow access to the deck. The removal of the deck, particularly beneath the boiler will allow steel plate to be inserted into the Hold tankage space to repair both longitudinal and transverse frame plating. Other areas remote from where the overhead deck is to be repaired will require cutting/burning into those tanks below to affect repairs beneath the boilers; these cuts can be reversed by re-installing the cut-out deck plating. Tasking for B-4-4-W Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR Crop and replace longitudinal plating (1/2 x 18L x 4 H) on #1 longitudinal,. 72 sq. ft x ½ Crop and replace longitudinal plating (1/2 x 18 L x 4 H) on #2 longitudinal. 72 sq. ft x ½ Crop and replace transverse plating (3/8 x 24 L x 4 H on # 1 transverse 96 sq. ft x 3/8 Crop and replace transverse plating (3/8 x 24 L x 4 H on # 2 transverse 96 sq. ft x 3/8 Crop and replace transverse plating (3/8 x 24 L x 4 H on # 3 transverse 96 sq. ft x 3/8 Crop and replace transverse plating (3/8 x 24 L x 4 H on # 4 transverse 96 sq. ft x 3/8 Replace four 1/2 plating knees for boiler foundations. 40 sq. ft x 3/8 Replace two 1/2 x 4 x 10 x 24 channel beams for boiler foundations. Prime all new work with two coats of INTERNATIONAL 300V epoxy primer. Once the tankage below has been repaired, the deck can be repair/replaced as needed. 8. B-4, HOLD TANKAGE, Frames ½ (cont.) 28
35 8.2 B-4-1-W, STARBOARD, RESERVE FEED WATER TANK (cont.) Figure 41: Typical Condition with Holed Plating on Overhead within B-4-1-W Figure 42: Typical Condition within B-4-1-W 8. B-4, HOLD TANKAGE, Frames ½ (cont.) 29
36 8.3 B-4-4-W, PORT, RESERVE FEED WATER TANK Not previously inspected under the Option 1 Survey, this tank space with four transverse frames and two longitudinal frames is directly under both boiler room fuel manifolds and miscellaneous components; tank components are in fair/good structural condition with no repairs required at this time. Both transverse and longitudinal support frames are intact with plate loss in areas averaging 30 40% with minimal deflection of steel plate. The floor of this tankage is heavily rusted/scaled with greater than 30-50% wastage, but with no standing water present. Forward bulkhead intact showing 30-40% plate loss and the aft bulkhead intact with 40-50% plate loss with heavy rust/scale present. Vertical scantlings on both fore and aft and outboard bulkheads intact. Centerline keel plate shows plate loss of 40% in areas of deep pitting, but is not in need of repair at this time. Figure 43: Typical Condition within B-4-4-W Figure 44: Typical Condition within B-4-4-W 8. B-4, HOLD TANKAGE, Frames ½ (cont.) 30
37 8.4 B-4-3-W, STARBOARD, RESERVE FEED WATER TANK Not previously inspected under the Option 1 Survey, this tank space with four transverse frames and two longitudinal frames is directly under both boiler room fuel manifolds and miscellaneous components; tank components are in fair/good structural condition with no repairs required at this time. Both transverse and longitudinal support frames are intact with plate loss in areas averaging 30 40% with minimal deflection of steel plate. The floor of this tankage is heavily rusted/scaled with greater than 30-50% wastage, but with no standing water present. Forward bulkhead intact showing 30-40% plate loss and the aft bulkhead intact with 40-50% plate loss with heavy rust/scale present. Vertical scantlings on both fore and aft and outboard bulkheads intact. Centerline keel plate shows plate loss of 40% in areas of deep pitting, but is not in need of repair at this time. Figure 45: Typical Condition of B-4-3-W Figure 46: Typical Condition of B-4-3-W 9. B-4, INNER BOTTOM TANKAGE, Frames /2 31
38 Tankage within the Inner Bottom (B-94W, B-95W, B-96W & B-97W) will not be repaired under Option B-4, NAVAL ARCHITECT S COMMENTS ON TANK REPAIRS 10.1 SUSPENSION OF BOILERS WITHIN B-4 Suspension of the boilers by the means proposed will replace the existing rotting foundations with significantly stronger material which is substantially indestructible. Suspension of the boilers will move the point of support of these large weights from the bottom structure to the decks above. Based on the location of the boiler spaces between the forward and after turrets and barbettes means the ship will normally be in a hogging condition and the decks overhead will be in tension. Suspending the boilers would reduce the stresses in the deck, although the positive effects would be small REPAIR OF FLOOR WITHIN B-4 Replacement of rusted and holed deck plating with solid plates would increase the strength of the lower hull in the midship area. Although the stresses would be relatively low in the static condition, they will increase as the ship lands on the proposed sand bed. Although the ship should land at the bow first, the midship section will see varying stresses with the possibility of a rip in the lower plates introducing water into the boiler rooms REPAIR TO B-4-2-W Replacement of weakened structure in the Port RFW tank will add stiffening to the structure under the boiler room deck. This will strengthen the lower flange of the midship section of the main hull girder and reduce the chance of failure while the ship waits on Option 5 and during the bottoming REPAIR TO B-4-1-W Replacement of weakened structure in the Starboard RFW tank will add stiffening to the structure under the boiler room deck. This will strengthen the lower flange of the midship section of the main hull girder and reduce the chance of failure while the ship waits on Option 5 and during the bottoming. 11. INNER BOTTOM TANKAGE, Frames 77 ½ - 89 Tankage within the Inner Bottom Tankage (B-98V, B-99V, C-90F, C-91F, C-92F & C-93F) will not be repaired under Option 5. 32
39 12. ENGINEROOMS, C-1 & C-2, Frames Figure 47: Enginerooms C-1 & C-2 within Hold Spaces 12.1 ENGINE SUPPORTS (C-1, STARBOARD & C-2, PORT) C-1 Starboard. This space has seen extensive restoration efforts, and is open to the public. The space is well lighted, has adequate handrails and fencing containment to keep the public above the lower flats of the engineroom, excellent footing and grab rods. The space is in superb cosmetic condition. All asbestos lagging has been properly remediated. C-2 Port. This space has not seen extensive restoration efforts, and is not generally open to the public. The space is poorly lighted, has adequate handrails but poor fencing containment to keep the public above the lower flats of the engineroom, excellent footing and grab rods. The space is in poor cosmetic condition. Most asbestos lagging has been properly remediated. Of concern is the foundation for these engines in that the weight of this structure depends upon 33
40 12. ENGINEROOMS, C-1 & C-2, Frames (cont.) 12.1 ENGINE SUPPORTS (C-1, STARBOARD & C-2, PORT) (cont.) the strength of the underlying trio of inner bottom tank scantlings. There is very little meat left within the scantlings below (engine room floor, transverse frames, longitudinal frames, keel) the main engine; therefore a rebuilding of the system of bulkheads and frames (both transverse and longitudinal) for both enginerooms is appropriate. The pair of main engine base foundations have also been impacted by corrosion issues to a lesser extent. Other major components, foundations and platforms in this space are in fine shape but all suffer from a lack of support from the inner bottom tanks. Fore and aft bulkheads for both enginerooms are holed with serious corrosion issues and must be repaired/replaced. The schedule of tasking requires the following: 1) Perform any asbestos remediation on friable asbestos before any work is contemplated. 2) Remediate any sanding wet or dried oil on floors or other surfaces within engineroom spaces prior to any hotwork. 3) Remove any obstructions, wiring, piping in way of lay-down area of supporting I-beams on protective deck. 4) Have both enginerooms and Inner Bottom Tanks cleaned and free of oil (especially C-1, C-2, C- 95, C-97, & C-99F) for hot work. Contiguous tankage that requires cleaning of any/all oil residue are as follows for hot work: C-92F, C-93F, C-84F, C-86F, C-88F, D-92F, D-97F, C-85F, C-87F, C-89F, D-91F. 5) Map prior to removal and remove any fuel piping and appurtenances in way of Inner Bottom Tankage (vertical stanchions & gratings). For the purposes of cost estimating, the size of the hardware used to suspend the engines is approximated. The final method of removing the load of the engines from the structure beneath will require design by a licensed engineer. 6) Provide twenty two (22) 2 6 x 19 bright wire slings of suspension/support, from the armored deck above and rigid steel supports from the centerline wiring trunk and outboard bulkhead, of the triple expansion steam engine and thrust block. This system of support shall provide both vertical and lateral support for the main steam engine and thrust block. This tasking must be accomplished before any work within the Inner Bottom tanks is contemplated. Install ten (five per side) 1 x 10 steel plate brackets to support lateral support of main engine; attach to engine foundations 7) The main engines weigh 1,045 tons each or 2,090,000 pounds. The support for the engines can be achieved by suspending them from the armored protective deck above utilizing twenty-two (22) 2 classified 2 6 x 19 coated or drawn galvanized bright steel cables slung under the major engine bed support components thence to the overhead deck where sistered 14 x 16 I-beams will rest on the deck with 2 x 7 threaded rod attached to the cable ends. The cable ends will be attached to 2 bright wire (as described above ), coated, fiber core (FC) wire rope improved plow steel (IPC) with a breaking load of 396,000 lbs each for a total support capacity of 8,712,000 pounds of support for a safety factor of four (4). The threaded rod can be tensioned to just take the load of 34
41 12. ENGINEROOMS, C-1 & C-2, Frames (cont.) 12.1 ENGINE SUPPORTS (C-1, STARBOARD & C-2, PORT) (cont.) the boiler off of the sub-structure allowing repairs to be made in safety. These cables include a safety factor of four (4) and will be tested with dial indicators for working loads. Section 106 remediation to put this back to original would re-quire removal of the support gear and welding the circular holes in the armor deck back to original. 8) Return space(s) to original upon completion of repairs. The drawing below pertains to the side view of the pair of I-beams for each engine resting on the armored protective deck over the main engines (both similar) in C-1 & C-2 Enginerooms. Figure 48: Side View of Main Engine with Support Wires; Typical for Both Main Engines (Hardware sizes estimated) 35
42 12. ENGINEROOMS, C-1 & C-2, Frames (cont.) 12.1 ENGINE SUPPORTS (C-1, STARBOARD & C-2, PORT) (cont.) Figure 49: Starboard Main Engine, Looking Forward Showing Side Supports and Overhead Wires (Hardware sizes estimated) Materials Eight 14 x 16 x 66 I-beams Four 2 x 32 W x 66 A-36 Flat Steel Plate Forty-four (44) 2 x 60 wire with eyes and fendering Forty-four (44) 2 classed proofed shackles, 2 classed nuts, fender washers Forty four (44) 2 x 3 long threaded rod with eyes 36
43 12.2 ENGINEROOM DECK REPLACEMENT (C-1, STARBOARD & C-2, PORT) The deck in both Enginerooms are deteriorated and require replacement to make that space watertight Completely photo document and record textual information about all piping, electrical and structural members in way spaces above engineroom floors for Section 106 requirements and present documentation to Project Manager. Verify that piping is not filled with oil, remediate as needed. Remediate red lead where steel is to be cut 4 to either side of cut/welded seam per 29 CFR. Remove all piping, deck gratings, stanchions for deck gratings, minor equipment to allow access to floor plating. Remove old floors as needed. Weld 3,600 square feet of new ½ NSTM A-36 steel plate into exposed areas over Inner Bottom tankage. Prime floor with two coats of International 300V primer. Upon completion of repairs, return all spaces to original configuration. 13. NAVAL ARCHITECT COMMENTS ON ENGINE SUPPORTS The main engines are the largest individual items on the battleship and therefore must be secured such that any movement relative to the ship is impossible. The upper decks represent the sturdiest structure on the ship and are the best support for weights of this magnitude. The suspension from the overhead will safely tie the weights to the ships main hull girder. The welded plates to the centerline bulkhead and engineroom outboard bulkheads will ensure no lateral movement, completing the fixing of the two large weights in all three dimensions. 14. INNER BOTTOM TANKAGE, FRAMES Figure 50: Inner Bottom Tankage, Frames
44 14. INNER BOTTOM TANKAGE, FRAMES (cont.) 14.1 DESCRIPTION These six tanks, under the pair of steam engines, are free flooding from various areas including the bottom plating. There are six (6) fuel tanks under the pair of main triple expansion steam engines. All tanks need to be completely rebuilt with regard to transverse and longitudinal frames, transverse bulkheads and Frames 89, 94, 99, and 104. All of these main transverse bulkheads are holed and require repair. Likewise, the main longitudinals (1-4) and transverse frames throughout are severely degraded and in some cases do not exist. The centerline keel requires repair. Bottom plating shall not be repaired under Option # EMERGENCY FUEL TANK, C-94F PORT Cut into Engineroom deck for access as needed for tank. Crop and replace portion of forward bulkhead at Frame # 89 from keel to tank boundary. 1/2 x 4 ½ x 40 A-36 steel plate. Crop and replace portion of aft bulkhead at Frame # 94 from keel to tank boundary. 1/2 x 4 ½ x 40 A-36 steel plate. Crop and replace Longitudinals # 1 4 to tank boundary. 1/2 x 4 ½ x 80 A-36 steel plate. Crop and replace main Transverses (4) from keel to tank boundary. 3/8 x 4 ½ x 160 A-36 steel plate Crop & replace intermediate Transverses (4) from keel to #4 Longitudinal 3/8 x 4 ½ x 128 A-36 steel plate Re-install disturbed overhead deck plating to original. Prime all new surfaces with International 300V primer EMERGENCY FUEL TANK, C-95F STARBOARD Cut into Engineroom deck for access as needed for tank. Crop and replace portion of forward bulkhead at Frame # 89 from keel to tank boundary. 1/2 x 4 ½ x 40 A-36 steel plate. Crop and replace portion of aft bulkhead at Frame # 94 from keel to tank boundary. 1/2 x 4 ½ x 40 A-36 steel plate. Crop and replace Longitudinals # 1 4 to tank boundary. 1/2 x 4 ½ x 80 A-36 steel plate. Crop and replace main Transverses (4) from keel to tank boundary. 3/8 x 4 ½ x 160 A-36 steel plate Crop & replace intermediate Transverses (4) from keel to #4 Longitudinal 3/8 x 4 ½ x 128 A-36 steel plate. 38
45 14. INNER BOTTOM TANKAGE, FRAMES (cont.) Re-install disturbed overhead deck plating to original. Prime all new surfaces with two coats of International 300V primer EMERGENCY FUEL TANK, C-96F PORT Cut into Engineroom deck for access as needed for tank. Crop and replace portion of aft bulkhead at Frame # 99 from keel to tank boundary. 1/2 x 4 ½ x 40 A-36 steel plate. Crop and replace Longitudinals # 1 4 to tank boundary. 1/2 x 4 ½ x 80 A-36 steel plate. Crop and replace main Transverses (4) from keel to tank boundary. 3/8 x 4 ½ x 160 A-36 steel plate Crop & replace intermediate Transverses (4) from keel to #4 Longitudinal 3/8 x 4 ½ x 160 A-36 steel plate Re-install disturbed overhead deck plating to original. Prime all new surfaces with International 300V primer EMERGENCY FUEL TANK, C-97F STARBOARD Cut into Engineroom deck for access as needed for tank. Crop and replace portion of aft bulkhead at Frame # 99 from keel to tank boundary. 1/2 x 4 ½ x 40 A-36 steel plate. Crop and replace Longitudinals # 1 4 to tank boundary. 1/2 x 4 ½ x 80 A-36 steel plate. Crop and replace main Transverses (4) from keel to tank boundary. 3/8 x 4 ½ x 160 A-36 steel plate Crop & replace intermediate Transverses (5) from keel to #4 Longitudinal 3/8 x 4 ½ x 160 A-36 steel plate Re-install disturbed overhead deck plating to original. Prime all new surfaces with International 300V primer EMERGENCY FUEL TANK, C-98F PORT Cut into Engineroom deck for access as needed for tank. Crop and replace portion of aft bulkhead at Frame # 104 from keel to tank boundary. 1/2 x 4 ½ x 40 A- 36 steel plate. Crop and replace Longitudinals # 1 4 to tank boundary. 1/2 x 4 ½ x 80 A-36 steel plate. Crop and replace main Transverses (4) from keel to tank boundary. 3/8 x 4 ½ x 160 A-36 steel plate Crop & replace intermediate Transverses (2) from keel to #4 Longitudinal 3/8 x 4 ½ x 80 A-36 steel plate. 39
46 14. INNER BOTTOM TANKAGE, FRAMES (cont.) Re-install disturbed overhead deck plating to original. Prime all new surfaces with International 300V primer EMERGENCY FUEL TANK, C-99F STARBOARD Cut into Engineroom deck for access as needed for tank. Crop and replace portion of aft bulkhead at Frame # 104 from keel to tank boundary. 1/2 x 4 ½ x 40 A- 36 steel plate. Crop and replace Longitudinals # 1 4 to tank boundary. 1/2 x 4 ½ x 80 A-36 steel plate. Crop and replace main Transverses (4) from keel to tank boundary. 3/8 x 4 ½ x 160 A-36 steel plate Crop & replace intermediate Transverses (2) from keel to #4 Longitudinal 3/8 x 4 ½ x 80 A-36 steel plate Re-install disturbed overhead deck plating to original. Prime all new surfaces with International 300V primer KEEL The keel within these Inner Bottom Tanks is badly compromised in that the vertical flat plate is badly pitted and holed throughout; the side support flanges are also badly degraded, deflected and holed. It is proposed to replace the vertical flat plate and flanges within this space. Crop and replace vertical flat plating of keel with new ¾ x 4 ½ x 64 long A-36 steel plate between Frames Figure 51: Detail Sampling of Flat Plate of Keel Crop and replace diagonal support brackets (52) for keel with new ¾ A-36 steel plate; weld to new vertical keel plate and base of old flange between every transverse frame. Re-install disturbed overhead deck plating to original. Prime all new surfaces with International 300V primer. 40
47 14. INNER BOTTOM TANKAGE, FRAMES (cont.) 14.8 KEEL (cont.) Figure 51A: Detail Sampling of End on View of Keel Showing Diagonal Support Brackets 15. NAVAL ARCHITECT S COMMENTS ON INNER BOTTOM REPAIRS TO FRAMES, BULKHEADS & KEEL, FRAMES The bottom structure under the engine rooms represents the most important area of degraded structure on the battleship. In addition to supporting the main engines, it also ties in the structure supporting the two after turrets and barbettes. In the ship's current situation, largely bottomed out in the stern, the two turrets are supported by the residual strength in the bottom structure but mainly are cantilevered off the upper decks and the above waterline side shell. When the slip is super-flooded and the battleship is again afloat, there is a possibility that the diminished strength in the lower flange of the hull girder in this area will fail. Even a small failure could cause the bottom and lower shell plating to buckle, allowing increased flooding at the least and possibly leading to more deflection of the ship aft of turret #3. If the stern were to sag, rebuilding the battleship to remedy the situation would present a problem too extreme to contemplate. Replacing the structure as proposed herein is the only sensible proposal. 16. INNER BOTTOM TANKAGE, FRAMES Tankage within the Inner Bottom Tankage (D-97 & D-98V) will not be repaired under Option 5. 41
48 17. AFTER EMERGENCY DIESEL GENERATOR ROOM, D-11, Frames Figure 52: Aft Emergency Diesel Generator Room This space contains the aft emergency diesel generator and switchboards. Condition of the floor and foundations for the diesel generator is poor with the possibility that the generator could fall through the floor and subsequent bottom shell plating. Forward and aft bulkhead are in poor repair with heavily corroded walls as this space was previously flooded for a long period of time. This room is sized approximately 20 L x 24 W. Perform oil remediation on D-11 & D-98F and make safe for hotwork. Perform asbestos & PCB remediation on this space before any work is contemplated. Perform remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR Crop and replace approximately 180 sq. ft. of bulkhead at Frame # 115 with 3/8 A-36 steel plate. Crop and replace approximately 180 sq. ft. of bulkhead at Frame # 120 with 3/8 A-36 steel plate. Remove/replace wasted door frame and install new 30 x 60 dogging door at Frame # 120, aft bulkhead. Figure 53: Forward Bulkhead in Aft Emergency Diesel Generator Room at Frame #115, Showing Plate Replacement 42
49 17. AFTER EMERGENCY DIESEL GENERATOR ROOM, D-11, Frames (cont.) Coat all surfaces with two coats of INTERNATIONAL 300V epoxy primer. Figure 54: Aft Bulkhead in Aft Emergency Diesel Generator Room at Frame #120, Showing Plate Replacement For the purposes of cost estimating, the size of the hardware used to suspend the diesel generator is approximated. The final method of removing the load of the diesel generator from the structure beneath will require design by a licensed engineer. Generator weighs a maximum of 25 tons and a safety factor of four is recommended to support the diesel generator. Install four bolted pad eyes from pair of transverse frames over diesel generator. Suspend diesel generator from overhead with two 1 6 x ton nominal breaking strength classed bright wire shackled into existing 3/8 x 3 x 10 transverse frames pad eyes. Figure 55: Side View of Aft Emergency Diesel Generator Suspended from Overhead (Hardware sizes estimated) 43
50 17. AFTER EMERGENCY DIESEL GENERATOR ROOM, D-11, Frames (cont.) Figure 56: Frontal View of Aft Emergency Diesel Generator Suspended from Overhead (Hardware sizes estimated) Upon completion of suspension of diesel generator from overhead, remove any appurtenances in way of work which may include piping, wire trunks and other equipment resting on floors. Upon completion of repairs to Inner Bottom Tank D-99F, insert new 3/8 A-36 steel deck to Aft Emergency Diesel generator Room. Crop out existing wasted deck and install 500 sq. ft of 3/8 A-36 steel decking. Prime all new surfaces with two coats of International 300V primer. Figure 57: Aft side of Emergency Diesel Generator in D-11 44
51 18. NAVAL ARCHITECT S COMMENTS ON REPAIRS TO AFT EMERGENCY DIESEL GENERATOR ROOM, D-11, Frame Suspension of the diesel generator will be relatively straight forward and removes the danger that sudden movement of the battleship would shake the machinery loose from its degraded supports. Raising of the unit will permit safe removal and replacement of the structure at a time of the projects choosing. 19. VOID SPACE, D-99, Frames Figure 58: Void D-99V, Inner Bottom Tankage This space is directly under the Aft Emergency Diesel Room and is in poor structural condition. All transverse and longitudinal frames shall be replaced, the fore and aft bulkheads shall be replaced and the keel shall be repaired. Size of space is approximately 40 W x 28 long. After removal of overhead deck plating complete the following: Ensure cleaning and certification of spaces D-98F, D-95V and D-96V are safe for hotwork. Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR Crop and replace longitudinal plating (1/2 x 28L x 4 H) on #1 longitudinal,. 112 sq. ft x ½ Crop and replace longitudinal plating (1/2 x 18 L x 4 H) on #2 longitudinal. 112 sq. ft x ½ Crop and replace longitudinal plating (1/2 x 18 L x 4 H) on #3 longitudinal. 112 sq. ft x ½ 45
52 19. VOID SPACE, D-99, Frames (cont.) Crop and replace transverse plating (3/8 x 30 L x 4 H on # 1 transverse 120 sq. ft x 3/8 Crop and replace transverse plating (3/8 x 30 L x 4 H on # 2 transverse 120 sq. ft x 3/8 Crop and replace transverse plating (3/8 x 30 L x 4 H on # 3 transverse 120 sq. ft x 3/8 Crop and replace transverse plating (3/8 x 30 L x 4 H on # 4 transverse 120 sq. ft x 3/8 Crop and replace transverse plating (3/8 x 28 L x 4 H on # 5 transverse 112 sq. ft x 3/8 Crop and replace transverse plating (3/8 x 28 L x 4 H on # 6 transverse 112 sq. ft x 3/8 Crop and replace vertical flat plating of keel with new ¾ x 4 ½ x 24 long A-36 steel plate between Frames Figure 59: Detail Sampling of Flat Plate of Keel within D-99V from Frames Crop and replace diagonal support brackets (26) for keel with new ¾ A-36 steel plate; weld to new vertical keel plate and base of old flange between every transverse frame. Crop out and replace both forward and aft bulkhead of tank with, approx. 300 sq. ft of 3/8 A-36 steel plate. Prime all new work with two coats of INTERNATIONAL 300V epoxy primer. Once the tankage below has been repaired, the deck can be repair/replaced as needed. 20. NAVAL ARCHITECT S COMMENTS ON REPAIRS TO VOID D-99V, Frames Replacement of the degraded structure will permit maintaining the shape of the stern and allow the bottoming of the battleship in Option 5 without the possibility of "crumpling" the aft end. 46
53 21. DISCUSSION OF REPAIRS TO AFT END OF SHIP, FRAMES 122 AFT PERPENDICULAR Figure 60: Detail of Stern Repair Area The Hull Survey conducted in December 2010 January 2011 and the latest inspection of January 2012 revealed serious degradation in the aft area of the ship from Frame 123 to the stern, this area of degradation extended upward from the keel, side shell transverse frames, bulkheads and vertical stanchions up to the bottom of the 2 nd Deck. The following repairs propose to remedy this situation and afford ample strength for the vessel when she if super-flooded and, later, set down on the hard within the Option 5 berm. The schedule of repairs commences from the keel upward and outward to the bottom of the 2 nd Deck and will be labeled deck-bydeck for easiest understanding. Shell plate leakage will be addressed once main transverse frames are installed in order to give the fabricators something to tie steel cofferdam to between frames. This schedule of repairs is how this type of restoration would be performed and allow strength to support upper deck weights in a systematic way ND PLATFORM & HOLD, TRIMMING TANK (D-12) & STOREROOMS OUTBOARD OF STEERING ROOM (D-25), Frames Figure 61: Trimming Tank, D-12 47
54 22. 2 ND PLATFORM & HOLD, TRIMMING TANK (D-12) & STOREROOMS OUTBOARD OF STEERING ROOM (D-25), Frames (cont.) This trimming tank is a large open space with fore and aft bulkheads and main transverse frames and vertical steel stanchions supporting the overhead. Much of the support framing and all of the stanchions require replacement. The bulkheads, likewise, require replacement. Figure 62: Typical Main Transverse and Longitudinal Frame in D-12 Trimming Tank Figure 63: Wasted Longitudinal and Transverse Frames to Starboard between Frame Notice Seepage and Run-off from Leaking Shell Plating in D-12 Trimming Tank. 48
55 22. 2 ND PLATFORM & HOLD, TRIMMING TANK (D-12) & STOREROOMS OUTBOARD OF STEERING ROOM (D-25), Frames (cont.) The schedule of repairs in D-12 shall proceed as follows: Install adequate lighting for entire compartment. Install new ladders for forward and aft scuttles to safely access D-12 Trimming Tank. Ensure that there is no disturbance of the bilge pump float switch and intake hoses. Install framework for installing wood plank floor for footing and remove as repairs proceed from forward to aft. Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR for D-26P, D-26S & D- 12 Crop and install new 3/8 steel bulkhead at Frame sq. ft. x 3/8 Figure 64: Plate Replacement at Transverse bulkhead at Frame # 123 Install new 3/8 steel bulkhead at Frame sq. ft. x 3/8 Crop and replace vertical flat plating of keel with new ¾ x 4 ½ x 28 long A-36 steel plate between Frames sq. ft x ¾ Replace five (5) centerline 6 O.D. ½ wall vertical stanchions (3 of 12, 1 of 11, 1 of 10 ) and tie into keelson plate and overhead frames. 60 ½ wall tube Crop and replace longitudinal plating (1/2 x 18 L x 4 H) on #1 longitudinal. 40 sq. ft. x ½ Crop and replace longitudinal plating (1/2 x 18 L x 4 H) on #2 longitudinal. 70 sq. ft x ½ 49
56 22. 2 ND PLATFORM & HOLD, TRIMMING TANK (D-12) & STOREROOMS OUTBOARD OF STEERING ROOM (D-25), Frames (cont.) Crop and replace longitudinal plating (1/2 x 28L x 2 H) on #3 longitudinal, 70 sq. ft. x ½ Crop and replace longitudinal plating (1/2 x 28L x 2 H) on #4 longitudinal, 70 sq. ft. x ½ Crop and replace transverse plating (3/8 x 30 L x 2 H) on Frame 123 transverse 60 sq. ft x 3/8 Crop and replace transverse plating (3/8 x 30 L x 2 H) on Frame 124 transverse 60 sq. ft x 3/8 Crop and replace transverse plating (3/8 x 30 L x 2 H) on Frame 125 transverse 60 sq. ft x 3/8 Crop and replace transverse plating (3/8 x 30 L x 2 H on Frame 126 transverse 60 sq. ft x 3/8 Crop and replace transverse plating (3/8 x 28 L x 2 H on Frame 127 transverse 60 sq. ft x 3/8 Crop and replace transverse plating (3/8 x 28 L x 2 H on Frame 128 transverse 60 sq. ft x 3/8 Crop and replace floors in D-26P & D-26S Install interior cofferdam plating between Transverse Frames 122 and 129 from overhead to keel to contain shell plate leaks. 1,680 sq. ft x ¼ Coat all new work with two coats of INTERNATIONAL 300V primer. Figure 65: Transverse Frames in D-26P, D-26S & D-12 Trimming Tank 50
57 22. 2 ND PLATFORM, HOLD, TRIMMING TANK (D-12) & STOREROOMS OUTBOARD OF STEERING ROOM (D-25), Frames (cont.) Figure 66: Transverse Frames 127 in D-26P, D-26S & D-12 Trimming Tank Figure 67: Transverse frames 128 in D-26P, D-26S & D-12 Trimming Tank 51
58 22. 2 ND PLATFORM, HOLD, TRIMMING TANK (D-12) & STOREROOMS OUTBOARD OF STEERING ROOM (D-25), Frames (cont.) Figure 68: Transverse Frame 129 and Bulkhead in D-26P, D-26S & D-12 Trimming Tank Figure 69: Base of Centerline Wasted Stanchion Resting on Wasted Pedestal over Keel in D-12 Trimming Tank 52
59 23. NAVAL ARCHITECT S COMMENTS ON REPAIRS TO 2 ND PLATFORM, HOLD, TRIMMING TANK (D-12) & STOREROOMS OUTBOARD OF STEERING RAM ROOM (D-25), Frames Rebuilding Trim Tank D-12 and the storerooms will stiffen the aft end of the keel and ensure that if the battleship is not trimmed by the bow and does land on the aft end of the keel, it will not collapse. At the moment, it would not take much force in the area of Frame 129 to crush the severely degraded structure ND PLATFORM & HOLD, TRIMMING TANK D-13, STEERING GEAR ROOM D-27, Frames The Trimming Tank D-13 is accessed via a dogging scuttle to port in the Steering Ram Room. This space has much degradation within the transverse frames; however, the frames are on 2 centers and keel area looks to be in excellent shape all the way aft to the stern casting; very strong area of support for rudder and stern overhang. The keel is in good repair showing just % wastage and will not be the subject of any repairs at this time. The overhead frames and deck are in poor to fair condition and will be replaced as the heavy steering rams and rudder post ride on this deck. Figure 70: D-13 Trimming Tank, looking forward to Bulkhead at Frame 129 Figure 71: D-13 Trimming Tank, looking Aft to Stern Casting 53
60 24. 2 ND PLATFORM & HOLD, TRIMMING TANK D-13, STEERING GEAR ROOM D-27, Frames (cont.) The Steering Gear Room (D-27) sits atop the Trimming Tank (D-13) and is an open area with the heavy hydraulic components of the steering rams and rudder post. The deck is in poor condition and must be replaced. The bottom 4 of the side shell transverse frames are also in need of repair/replacement. Figure 72: Typical Base of Transverse Frame within D-27 Figure 73: Heavy Steering Rams and Rudder Post in D-27 54
61 24. 2 ND PLATFORM & HOLD, TRIMMING TANK D-13, STEERING GEAR ROOM D-27, Frames (cont.) The schedule of repairs for D-27 is as follows: Install adequate lighting for entire compartment. Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR. Crop and replace bottom 5 of plating on Transverse Frames throughout D-27with new 3/8 A-36 plating and match frame profiles 160 sq. ft x 3/8 plate For the purposes of cost estimating, the size of the hardware used to suspend the steering gear is approximated. The final method of removing the load of the steering gear from the structure beneath will require design by a licensed engineer. Suspend steering rams (100 tons) from overhead 3/8 x 4 x 10 channel transverse frames with four 1 ½ 6 x 19classed bright improved plow steel IRWC wire with a nominal strength of 114 tons with a safety factor of four (4). Four (4) 15 1 ½ 6 x 19 classed bright improved plow steel IRWC wire with eyes Eight (8) classed 1 ½ shackles Eight 1 1/2 steel pads with 3 eyes to mount to overhead frames Crop and replace bottom plating on Transverse Frames and base half Frames under rudder crosshead with new 1/2 A-36 plating and match frame profiles Replace aft Bulkhead at Frame 137. Upon suspension of steering gear, crop and replace deck throughout compartment with new ½ A-36 steel plate. 160 sq. ft. x 1/2 plate 80 sq. ft. x ½ plate 400 sq. ft. of ½ plate Coat all new work with two coats of INTERNATIONAL 300V Primer. Figure 74: Badly Corroded Scantlings Aft of Rudder Post 55
62 25. NAVAL ARCHITECT S COMMENTS ON REPAIRS TO 2 ND PLATFORM, HOLD, TRIMMING TANK (D-13) & STEERING RAM ROOM (D-27), Frames With respect to the steering gear rams and equipment it is necessary to suspend the weights from the Second Deck in order to safely replace the deteriorated foundations. Rebuilding the foundations will ensure these large weights do not tear loose and fall through the ships bottom nd PLATFORM VOID D-107, FRAMES 137 AFT PERPENDICULAR A large space just aft of the rudder post at the very stern of the ship. This space has large apron frames from top to bottom within this tank. All scantlings are heavily corroded due to poor drainage from weatherdecks. There are holes in the shell plating above the waterline to the exterior and cofferdam tankage above is heavily wasted and badly corroded. Figure 75: Upper Portion of D-107, showing Heavily Corroded Scantlings 56
63 26. 2 nd PLATFORM VOID D-107, FRAMES 137 AFT PERPENDICULAR (cont.) Figure 76: Stern Casting, showing Daylight through Wasted and Holed Shell Plating on Centerline above Waterline Figure 77: Heavily Wasted Transverse Frame at Base of Compartment 57
64 26. 2 nd PLATFORM VOID D-107, FRAMES 137 AFT PERPENDICULAR (cont.) The schedule of repairs for D-107 is as follows: Install adequate lighting for entire compartment. Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR. Crop and replace plating on Transverse Frames throughout D-27with new 3/8 A-36 plating and match frame profiles Crop out and replace three transverse bulkhead frames in base of compartment with new 3/8 A-36 plating and match frame profiles Install interior cofferdam plating between Transverse Frames 137 and 141 from overhead to keel to contain shell plate leaks. Install ¼ A-36 doubler plate over holed plating on transom above waterline. 200 sq. ft x 3/8 plate 140 sq. ft. x 3/8 plate 600 sq. ft x ¼ plate 300 sq. ft x ¼ plate Coat all new work with two coats of INTERNATIONAL 300V Primer. 27. NAVAL ARCHITECT S COMMENTS ON REPAIRS TO 2 ND PLATFORM VOID D- 107, FRAMES 137 AFT PERPENDICULAR Most of the structural elements in this area are firmly attached at the overhead and become progressively more deteriorated as you move deeper into the ship. That it has not already been torn apart is almost solely due to the fact that the only force on the steel is gravity. If the ship were afloat and attempting to steam and maneuver, it is likely that the entire stern would have collapsed. 28. VOIDS D-101, D-102, D-103, FRAMES These three void spaces (tapered in ascending height from forward to aft) are located directly over both the Steering Room and Steering Gear Room. These crawl spaces comprise the turtleback cover to the Steering Flats. Figure 78: Building the Void Spaces D-101, D-102 & D Photo courtesy of Texas parks & Wildlife (TPWD). 58
65 28. VOIDS D-101, D-102, D-103, FRAMES (cont.) Figure 79: D-101 looking Forward to Port Figure 80: D-102. Looking across Turtle back to Starboard Showing Wasted Vertical Stanchions 59
66 28. VOIDS D-101, D-102, D-103, FRAMES (cont.) Figure 81: Wasted Vertical Stanchion. Typical throughout D-101, D-102 & D-103. Figure 82: Wasted Vertical Stanchion 60
67 28. VOIDS D-101, D-102, D-103, FRAMES (cont.) Figure 83. Detail of Voids D-101, D-102, D-103 Install adequate lighting for entire compartment. Figure 84: Bird s Eye View of Voids D-101, D-102 & D-103 Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR. Crop and replace forty-eight (48) vertical stanchions through-out D-101, D-102 & D x 3/8 x 6 x 6 I-beams Crop out and replace ninety-six (96) stanchion bases 1 steel pads throughout D-101, D-102 & D x 1 x 8 x 8 steel plate Crop out and replace wasted bulkheads at Frame # 134 & # 137. Coat all new work with two coats of INTERNATIONAL 300V Primer. 61
68 29. NAVAL ARCHITECT S COMMENTS ON REPAIRS TO VOIDS D-101, D-102, D- 103, FRAMES The structure above the Third Deck provides stiffening to the Second Deck and will strengthen the stern area if the ship unexpectedly lands with stern trim. Added structure in this area will help support the steering rams and other equipment in the steering gear room. 30. THIRD DECK, CPO QUARTERS D-111, CPO MESS ROOM D-112, CPO PANTRY D-113 Figure 85: Bird s eye view of D-111, D-112 & D-113 This space contained berthing and clothing storage and is a side-to-side wide open space with vertical stanchions supporting the base of the 2 nd Deck. Many of the vertical stanchions in this space are degraded and must be replaced, a serious structural issue. The deck itself is badly corroded pointing to past standing water from poor drainage from upper decks. The tank tops on the exterior skin of the vessel are swiss cheese and are badly corroded; internal scantlings for the cofferdam spaces outboard are badly corroded, but are not considered a threat to the structural integrity of the ship at this time. Forward and aft vertical steel bulkheads at Frames # 122 & # 131 are seriously corroded, particularly at the deck line and do not provide any vertical support to the 2 nd Deck. 62
69 30. THIRD DECK, CPO QUARTERS D-111, CPO MESS ROOM D-112, CPO PANTRY D-113 (cont.) D-111 Install adequate lighting for entire compartment. Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR. Crop and replace six (6) 5 O.D. x ½ wall vertical stanchions in D-111 Crop out and replace twelve (12) stanchion bases 1 steel pads in D-111 Crop out and replace wasted bottom 3 bulkheads at Frame # 134 & # x 5 O.D. x 86 stanchions 12 x 1 x 8 x 8 steel pads 370 sq. ft. of 3/8 A-36 plate Coat all new work with two coats of INTERNATIONAL 300V Primer. Figure 86: Looking to Starboard in D-111 Figure 87: Wasted Stanchion Base in D
70 30. THIRD DECK, CPO QUARTERS D-111, CPO MESS ROOM D-112, CPO PANTRY D-113 (cont.) D-112 Install adequate lighting for entire compartment. Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR. Crop and replace three (3) 5 O.D. x ½ wall vertical stanchions in D-112 Crop out and replace six (6) stanchion bases 1 steel pads in D-111 Crop out and replace wasted bottom 3 bulkheads at Frame # x 5 O.D. x 86 stanchions 12 x 1 x 8 x 8 steel pads 150 sq. ft. of 3/8 A-36 plate Coat all new work with two coats of INTERNATIONAL 300V Primer. Figure 88: D-112 CPO Mess Space Figure 89: Wasted Stanchion Base in D
71 30. THIRD DECK, CPO QUARTERS D-111, CPO MESS ROOM D-112, CPO PANTRY D-113 (cont.) D-113 Install adequate lighting for entire compartment. Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR. Crop and replace two (2) 5 O.D. x ½ wall vertical stanchions in D-113 Crop out and replace four (4) stanchion bases 1 steel pads in D-113 Crop out and replace wasted deck in C x 5 O.D. x 86 stanchions 4 x 1 x 8 x 8 steel pads 50 sq. ft. of 3/8 A-36 plate Coat all new work with two coats of INTERNATIONAL 300V Primer. Figure 90: Looking to Starboard in D-113 Figure 91 Looking to Aft in D
72 31. NAVAL ARCHITECT S COMMENTS ON REPAIRS TO THIRD DECK, CPO QUARTERS D-111, CPO MESS ROOM D-112, CPO PANTRY D-113 The large weight concentrations on the fantail, especially the 40mm gun mounts and gun shields, are almost solely being supported by the Second and Main Decks cantilevered off the forward portion of the ship. In order to avoid the possibility of the stern sagging it is necessary to restore the support of the fantail to the below deck structure. Although this area will not be supported by the sand in Option 5, it will lose the support of the buoyancy of the water, which is substantial. 32. SUMMARY This report attempts to put repairs that are required for the Option 5 proposal into perspective with regard to sequencing of repairs, materials required and estimated costs for this progression. The costs for the tasking described within the body of this report is attached within the Appendix. The repairs that have been described are not the total of work that needs to be accomplished under Option 5, but represents approximately a 70% threshold of repairs estimated needed to carry out this progression. Further inspection of tankage out to the sides of the ship, up to the waterline and blister tank inspections were not carried out and there remains questions about the viability of keeping the hull watertight during the super-flooding process. Section 106 concerns are mostly surrounding cuts to be made for access to spaces; the solution for any and all concerns in this area is to put the area back to the appearance and condition before work/remediation commenced. Repairs have been kept to the absolute minimum, but are thorough where structural rigidity is needed. Respectfully submitted, Joseph Lombardi Marine Surveyor Jerry Possehl Naval Architect 66
73 33. APPENDIX 67
74 SUMMARY OF TASKING Task #4 $ 1,379, Task 5.3 B-3-4-W, Port, Reserve Feed Water Tank 222, Task 5.4 B-3-3-W, Starboard, Reserve Feed Water Tank 222, Task 8.1 B-4-2-W, Port, Reserve Feed Water Tank 251, Task 8.2 B-4-3-W, Starboard, reserve Feed Water Tank 251, Task 12.1 C-1 & C-2 1,556, Task 12.2 Replacement of C-1 & C-2 Engineroom Deck 2,745, Task 14.2 C-94F, Emergency Fuel Tank 1,027, Task 14.3 C-95F, Emergency Fuel Tank 1,027, Task 14.4 C-96F, Emergency Fuel Tank 1,062, Task 14.5 C-97F, Emergency Fuel Tank 1,062, Task 14.6 C-98F, Emergency Fuel Tank 900, Task 14.7 C-99F, Emergency Fuel Tank 900, Task 14.8 Keel 503, Task 17 D-11 Aft Emergency Diesel Generating Room 438, Task 19 D-99V 639, Task 22 D-12 Trimming Tank 1,150, Task 24 D-13 & D-27 Steering Gear Room 491, Task 26 Void D , Task 28 Voids, D-101, D-102, D , Task 30.1 CPO Berthing D , Task 30.2 CPO Mess D , Task 30.3 CPO Pantry D , Total $ 16,923, General Conditions 575, Contractor mob/demob with 40 x 110 spud barge, 100 ton crane, 35 ton crane, pusher tug, two 200 kw generators, one flatbed trailer, one Hyster fork truck, six welding machines, six oxy/acetylene units, one contractor trailer, power, phones, two Porti-Pottis 450, General Liability Insurance 55, Builder s Risk Insurance 32, Total $ 18,035, Bonds (2%) 360, Total $ 18,396, Profit & Overhead 15% 2,759, Total Cost of Project $ 21,155,
75 TASKING ESTIMATED COST Task 4 Tasking for Boiler Rooms # 3 & # 4, Frames 60 ½ /2 For the purposes of cost estimating, the size of the hardware used to suspend the boilers is approximated. The final method of removing the load of the boilers from the structure beneath will require design by a licensed engineer. The support for the boilers can be achieved by suspending them from the armor deck above utilizing steel cable fastened to 24 wide x 30 long double, 2 ply nylon straps (for supporting the underneath of the boiler) thence to the overhead deck where sistered 10 x 60 I-beams will rest on the deck with 1.25 x 7 threaded rod attached to the cable ends. The cable ends will be attached to 1.25 bright wire, uncoated, fiber core (FC) wire rope improved plow steel (IPC) with a breaking load of 129,200 lbs down to the nylon straps. The threaded rod can be tensioned to just take the load of the boiler off of the sub-structure allowing repairs to be made in safety. These cables and straps include a safety factor of four (4) and will be tested with dial indicators for working loads; anticipate three straps per boiler. Section 106 remediation to put this back to original would require removal of the support gear and welding the circular holes in the armor deck back to original. Remediation of asbestos as needed in Drying and Boiler Rooms #3 & #4. 170, Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR 74, Remediation of standing oil in Boiler Rooms, piping and tanks 75, Map & remove vertical stanchions and deck grating and piping/components over deck 75, Drill twenty-four (24) 2 holes in armor deck, suspend four (4) boilers 158, Twenty-four (24) 1 ¼ x 6 x 19 bright wire, uncoated, fiber core (FC) wire (IPC) with eyes 52, Twelve 2 ply 24 x 30 nylon straps 34, Twenty-four 1 ½ classed shackles 2, Twenty-four 1 1/4 x 2 threaded rod with eyes 5, Twenty-four 1 ¼ nuts Sixteen (16) 10 x 60 x 30 steel I-beams 28, x 24 x 240 plate steel 16, Crop out and replace 1,600 sq. ft of ½ A-36 steel deck plate as needed. 600, Re-install vertical stanchions and deck grating and piping/components over deck 75, Prime all new work with two coats INTERNATIONAL 300V epoxy prime (Labor & materials) 12, Task #4 $ 1,379,
76 TASKING ESTIMATED COST Task 5.3 B-3-4-W, Port, Reserve Feed Water Tank Tasking for B-3-4-W Tank repair methodology in B-3 requires that both boilers be supported as previously discussed in #4. The boiler room deck is perforated in many areas and needs to be replaced where it is holed. This will involve the mapping and and removal of the steel grating and associated piping beneath to allow access to the deck. The removal of the deck, particularly beneath the boiler will allow steel plate to be inserted into the Hold tankage space to repair both longitudinal and transverse frame plating. Other areas remote from where the overhead deck is to be repaired will require cutting/burning into those tanks below to affect repairs beneath the boilers; these cuts can be reversed by re-installing the cut-out deck plating. Tasking for B-3-4-W Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR $ 65, Crop/replace longitudinal plating (1/2 x 16L x 4 H) on #1 longitudinal 64 sq. ft x ½ 22, Crop/replace longitudinal plating (1/2 x 16 L x 4 H) on #2 longitudinal 64 sq. ft x ½ 22, Crop/replace transverse plating (3/8 x 24 L x 4 H) on # 1 transverse 96 sq. ft x 3/8 28, Crop/ replace transverse plating (3/8 x 24 L x 4 H) on # 2 transverse 96 sq. ft x 3/8 28, Crop/ replace transverse plating (3/8 x 24 L x 4 H) on # 3 transverse 96 sq. ft x 3/8 28, Replace four 1/2 plating knees for boiler foundations. 40 sq. ft x 3/8 12, Replace two 1/2 x 4 x 10 x 24 channel beams for boiler foundations. 7, Prime all new work with two coats INTERNATIONAL 300V epoxy primer. 7, Task 5.3 $ 222,
77 TASKING ESTIMATED COST 5.4 B-3-3-W, Starboard, Reserve Feed Water Tank Tasking for B-3-3-W Tank repair methodology in B-3 requires that both boilers be supported as previously discussed in #4. The boiler room deck is perforated in many areas and needs to be replaced where it is holed. This will involve the mapping and and removal of the steel grating and associated piping beneath to allow access to the deck. The removal of the deck, particularly beneath the boiler will allow steel plate to be inserted into the Hold tankage space to repair both longitudinal and transverse frame plating. Other areas remote from where the overhead deck is to be repaired will require cutting/burning into those tanks below to affect repairs beneath the boilers; these cuts can be reversed by re-installing the cut-out deck plating. Tasking for B-3-3-W Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR $ 65, Crop/replace longitudinal plating (1/2 x 16L x 4 H) on #1 longitudinal 64 sq. ft x ½ 22, Crop/replace longitudinal plating (1/2 x 16 L x 4 H) on #2 longitudinal 64 sq. ft x ½ 22, Crop/replace transverse plating (3/8 x 24 L x 4 H) on # 1 transverse 96 sq. ft x 3/8 28, Crop/ replace transverse plating (3/8 x 24 L x 4 H) on # 2 transverse 96 sq. ft x 3/8 28, Crop/ replace transverse plating (3/8 x 24 L x 4 H) on # 3 transverse 96 sq. ft x 3/8 28, Replace four 1/2 plating knees for boiler foundations. 40 sq. ft x 3/8 12, Replace two 1/2 x 4 x 10 x 24 channel beams for boiler foundations. 7, Prime all new work with two coats INTERNATIONAL 300V epoxy primer. 7, Task 5.4 $ 222,
78 TASKING ESTIMATED COST 8.1 B-4-2-W, PORT RESERVE FEED WATER TANK Tasking for B-4-2-W Tank repair methodology in B-4 requires that both boilers be supported as previously discussed in #4, The boiler room deck is perforated in many areas and needs to be replaced where it is holed. This will involve the mapping and removal of the steel grating and associated piping beneath to allow access to the deck. The removal of the deck, particularly beneath the boiler will allow steel plate to be inserted into the Hold tankage space to repair both longitudinal and transverse frame plating. Other areas remote from where the overhead deck is to be repaired will require cutting/burning into those tanks below to affect repairs beneath the boilers; these cuts can be reversed by re-installing the cut-out deck plating. Tasking for B-4-2-W Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR $ 65, Crop/replace longitudinal plating (1/2 x 16L x 4 H) on #1 longitudinal 64 sq. ft x ½ 22, Crop/replace longitudinal plating (1/2 x 16 L x 4 H) on #2 longitudinal 64 sq. ft x ½ 22, Crop/replace transverse plating (3/8 x 24 L x 4 H) on # 1 transverse 96 sq. ft x 3/8 28, Crop/ replace transverse plating (3/8 x 24 L x 4 H) on # 2 transverse 96 sq. ft x 3/8 28, Crop/ replace transverse plating (3/8 x 24 L x 4 H) on # 3 transverse 96 sq. ft x 3/8 28, Crop/replace transverse plating (3/8 x 24 L x 4 H) on # 4 transverse 96 sq. ft x 3/8 28, Replace four 1/2 plating knees for boiler foundations. 40 sq. ft x 3/8 12, Replace two 1/2 x 4 x 10 x 24 channel beams for boiler foundations. 7, Prime all new work with two coats INTERNATIONAL 300V epoxy primer. 7, Task 8.1 $ 251,
79 TASKING ESTIMATED COST 8.2 B-4-1-W, STARBOARD RESERVE FEED WATER TANK Tasking for B-4-1-W Tank repair methodology in B-4 requires that both boilers be supported as previously discussed in #4, The boiler room deck is perforated in many areas and needs to be replaced where it is holed. This will involve the mapping and removal of the steel grating and associated piping beneath to allow access to the deck. The removal of the deck, particularly beneath the boiler will allow steel plate to be inserted into the Hold tankage space to repair both longitudinal and transverse frame plating. Other areas remote from where the overhead deck is to be repaired will require cutting/burning into those tanks below to affect repairs beneath the boilers; these cuts can be reversed by re-installing the cut-out deck plating. Tasking for B-4-4-W Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR $ 65, Crop/replace longitudinal plating (1/2 x 16L x 4 H) on #1 longitudinal 64 sq. ft x ½ 22, Crop/replace longitudinal plating (1/2 x 16 L x 4 H) on #2 longitudinal 64 sq. ft x ½ 22, Crop/replace transverse plating (3/8 x 24 L x 4 H) on # 1 transverse 96 sq. ft x 3/8 28, Crop/ replace transverse plating (3/8 x 24 L x 4 H) on # 2 transverse 96 sq. ft x 3/8 28, Crop/ replace transverse plating (3/8 x 24 L x 4 H) on # 3 transverse 96 sq. ft x 3/8 28, Crop/replace transverse plating (3/8 x 24 L x 4 H) on # 4 transverse 96 sq. ft x 3/8 28, Replace four 1/2 plating knees for boiler foundations. 40 sq. ft x 3/8 12, Replace two 1/2 x 4 x 10 x 24 channel beams for boiler foundations. 7, Prime all new work with two coats INTERNATIONAL 300V epoxy primer. 7, Task 8.2 $ 251,
80 TASKING ESTIMATED COST 12.1 ENGINE SUPPORTS (C-1, STARBOARD & C-2, PORT) Tasking for C-1 & C-2 For the purposes of cost estimating, the size of the hardware used to suspend the engines is approximated. The final method of removing the load of the engines from the structure beneath will require design by a licensed engineer. Perform asbestos remediation on friable asbestos before any work is contemplated. $ 80, Map & remove any obstructions, wiring, piping in way of lay-down area of supporting I-beams on protective deck. Re-install upon completion of work. 200, Have both enginerooms and Inner Bottom Tanks cleaned and free of oil (especially C-1, C-2, C-95, C-97, & C-99F) for hot work. Contiguous tankage that requires cleaning of any/all oil residue are as follows for hot work: C-92F, C-93F, C-84F, C-86F, C-88F, D-92F, D-97F, C-85F, C-87F, C-89F, D-91F 425, Map prior to removal and remove any vertical stanchions, deck gratings, fuel piping and appurtenances in way of Inner Bottom Tankage. 150, Install twenty (five per side of engine) 1 x 12 x various length steel plate brackets to support lateral support of main engine; attach to engine foundations 25, Drill eighty-eight (88) 3 holes in armor deck, assemble I-beams, rod & suspension wires, suspend two (2) main engines 450, Materials Eight 14 x 16 x 66 I-beams 42, Four 2 x 32 W x 66 A-36 Flat Steel Plate 28, Forty-four (44) 2 x 60 wire with eyes and fendering 132, Forty-four (44) 2 classed proofed shackles, 2 classed nuts, fender washers 6, Forty four (44) 2 x 3 long threaded rod with eyes 14, Prime all new work with two coats INTERNATIONAL 300V epoxy prime (Labor & materials) 2, Return space(s) to original upon completion of repairs. Task 12.1 $ 1,556,
81 TASKING ESTIMATED COST 12.2 ENGINEROOM DECK (C-1, STARBOARD & C-2, PORT) Tasking for C-1 & C-2 Completely photo document and record textual information about all piping, electrical and structural members in way spaces above engineroom floors for Section 106 requirements and present documenttation to Project Manager. Verify that piping is not filled with oil, remediate as needed. Remediate red lead where steel is to be cut 4 to either side of cut/welded seam per 29 CFR. Remove all piping, deck gratings, stanchions for deck gratings, minor equipment to allow access to floor plating. Remove old floors as needed. Fabricate and install 3,600 square feet of new ½ NSTM A-36 steel plate into exposed areas over Inner Bottom tankage. Prime floor with two coats of International 300V primer. Upon completion of repairs, return all spaces to original configuration. Task 12.2 $ 2,745,
82 TASKING ESTIMATED COST 14.2 EMERGENCY FUEL TANK, C-94F PORT Tasking for C-94F Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR $ 65, Cut into Engineroom deck for access as needed for tank. 30, Crop/replace portion of forward bulkhead at Frame # 89 from keel to tank boundary (1/2 x 4 ½ x 40 A-36 steel plate) 180 sq. ft. x ½ 63, Crop/replace portion of aft bulkhead at Frame # 94 from keel to tank boundary (1/2 x 4 ½ x 40 A-36 steel plate) 180 sq. ft. x ½ 63, Crop/replace Longitudinals # 1 4 to tank boundary (1/2 x 4 ½ x 80 A-36 steel plate) 360 sq. ft. x ½ 126, Crop/replace main Transverses (4) from keel to tank boundary (3/8 x 4 ½ x 160 A-36 steel plate) 720 sq. ft x 3/8 216, Crop/replace intermediate Transverses (4) from keel to #4 Longitudinal (3/8 x 4 ½ x 128 A-36 steel plate) 576 sq. ft. x 3/8 172, Prime all new work with two coats INTERNATIONAL 300V epoxy prime (Labor & materials) 12, Return space(s) to original upon completion of repairs. 280, Task 14.2 $ 1,027,
83 TASKING ESTIMATED COST 14.3 EMERGENCY FUEL TANK, C-95F STARBOARD Tasking for C-95F Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR $ 65, Cut into Engineroom deck for access as needed for tank. 30, Crop/replace portion of forward bulkhead at Frame # 89 from keel to tank boundary (1/2 x 4 ½ x 40 A-36 steel plate) 180 sq. ft. x ½ 63, Crop/replace portion of aft bulkhead at Frame # 94 from keel to tank boundary (1/2 x 4 ½ x 40 A-36 steel plate) 180 sq. ft. x ½ 63, Crop/replace Longitudinals # 1 4 to tank boundary (1/2 x 4 ½ x 80 A-36 steel plate) 360 sq. ft. x ½ 126, Crop/replace main Transverses (4) from keel to tank boundary (3/8 x 4 ½ x 160 A-36 steel plate) 720 sq. ft x 3/8 216, Crop/replace intermediate Transverses (4) from keel to #4 Longitudinal (3/8 x 4 ½ x 128 A-36 steel plate) 576 sq. ft. x 3/8 172, Re-install disturbed overhead deck plating to original. 280, Prime all new surfaces with two coats International 300V primer. 12, Task 14.3 $ 1,027,
84 TASKING ESTIMATED COST 14.4 EMERGENCY FUEL TANK, C-96F PORT Tasking for C-96F Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR $ 65, Cut into Engineroom deck for access as needed for tank. 30, Crop/replace portion of aft bulkhead at Frame # 99 from keel to tank boundary (1/2 x 4 ½ x 40 A-36 steel plate) 180 sq. ft. x ½ 63, Crop and replace Longitudinals # 1 4 to tank boundary. 1/2 x 4 ½ x 80 A-36 steel plate. 360 sq. ft x ½ 126, Crop/replace main Transverses (4) from keel to tank boundary (3/8 x 4 ½ x 160 A-36 steel plate) 720 sq. ft x 3/8 216, Crop & replace intermediate Transverses (5) from keel to #4 Longitudinal (3/8 x 4 ½ x 200 A-36 steel plate) 900 sq. ft x 3/8 270, Prime all new work with two coats INTERNATIONAL 300V epoxy prime (Labor & materials) 12, Return space(s) to original upon completion of repairs. 280, Task 14.4 $ 1,062,
85 TASKING ESTIMATED COST 14.5 EMERGENCY FUEL TANK, C-97F STARBOARD Tasking for C-97F Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR $ 65, Cut into Engineroom deck for access as needed for tank. 30, Crop/replace portion of aft bulkhead at Frame # 99 from keel to tank boundary (1/2 x 4 ½ x 40 A-36 steel plate) 180 sq. ft. x ½ 63, Crop and replace Longitudinals # 1 4 to tank boundary. 1/2 x 4 ½ x 80 A-36 steel plate. 360 sq. ft x ½ 126, Crop/replace main Transverses (4) from keel to tank boundary (3/8 x 4 ½ x 160 A-36 steel plate) 720 sq. ft x 3/8 216, Crop & replace intermediate Transverses (5) from keel to #4 Longitudinal (3/8 x 4 ½ x 200 A-36 steel plate) 900 sq. ft x 3/8 270, Prime all new work with two coats INTERNATIONAL 300V epoxy prime (Labor & materials) 12, Return space(s) to original upon completion of repairs. 280, Task 14.5 $ 1,062,
86 TASKING ESTIMATED COST 14.6 EMERGENCY FUEL TANK, C-98F PORT Tasking for C-98F Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR $ 65, Cut into Engineroom deck for access as needed for tank. 30, Crop/replace portion of aft bulkhead at Frame # 104 from keel to tank boundary (1/2 x 4 ½ x 40 A-36 steel plate) 180 sq. ft. x ½ 63, Crop and replace Longitudinals # 1 4 to tank boundary. (1/2 x 4 ½ x 80 A-36 steel plate) 360 sq. ft x ½ 126, , Crop/replace main Transverses (4) from keel to tank boundary (3/8 x 4 ½ x 160 A-36 steel plate) 720 sq. ft x 3/8 216, Crop/replace intermediate Transverses (2) from keel to #4 Longitudinal (3/8 x 4 ½ x 80 A-36 steel plate) 360 sq. ft. x 3/8 108, Prime all new work with two coats INTERNATIONAL 300V epoxy prime (Labor & materials) 12, Return space(s) to original upon completion of repairs. 280, Task 14.6 $ 900,
87 TASKING ESTIMATED COST 14.7 EMERGENCY FUEL TANK, C-99F STARBOARD Tasking for C-99F Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR $ 65, Cut into Engineroom deck for access as needed for tank. 30, Crop/replace portion of aft bulkhead at Frame # 104 from keel to tank boundary (1/2 x 4 ½ x 40 A-36 steel plate) 180 sq. ft. x ½ 63, Crop and replace Longitudinals # 1 4 to tank boundary. (1/2 x 4 ½ x 80 A-36 steel plate) 360 sq. ft x ½ 126, Crop/replace main Transverses (4) from keel to tank boundary (3/8 x 4 ½ x 160 A-36 steel plate) 720 sq. ft x 3/8 216, Crop/replace intermediate Transverses (2) from keel to #4 Longitudinal (3/8 x 4 ½ x 80 A-36 steel plate) 360 sq. ft. x 3/8 108, Prime all new work with two coats INTERNATIONAL 300V epoxy prime (Labor & materials) 12, Return space(s) to original upon completion of repairs. 280, Task 14.7 $ 900,
88 TASKING ESTIMATED COST 14.8 KEEL, FRAMES Task for Keel Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR $ 35, Cut into Engineroom deck for access as needed for tank. 15, Crop/replace vertical flat plating of keel with new ¾ x 4 ½ x 64 long A-36 steel plate between Frames sq. ft x ¾ 125, Crop/ replace diagonal support brackets (52) for keel with new ¾ A-36 steel plate; weld to new vertical keel plate and base of old flange between every transverse frame. 416 sq. ft x ¾ 166, Prime all new work with two coats INTERNATIONAL 300V epoxy prime (Labor & materials) 12, Return space(s) to original upon completion of repairs. 150, Task 14.8 $ 503,
89 TASKING ESTIMATED COST 17. AFTER EMERGENCY DIESEL GENERATOR ROOM, D-11, Frames Tasking for D-11 For the purposes of cost estimating, the size of the hardware used to suspend the diesel generator is approximated. The final method of removing the load of the diesel generator from the structure beneath will require design by a licensed engineer. Perform asbestos & PCB remediation on this space before any work is contemplated. $ 45, Perform oil remediation on D-11 & D-98F and make safe for hotwork. 28, Remove gear in way of diesel generator, forward & aft bulkhead and re-install upon completion of repairs 15, Perform remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR 20, Crop/replace portion of forward bulkhead at Frame # 115 from top of keel to overhead (1/2 x 4 ½ x 40 A-36 steel plate) 180 sq. ft. x 3/8 54, Crop/replace portion of aft bulkhead at Frame # 104 from keel to overhead (1/2 x 4 ½ x 40 A-36 steel plate) 180 sq. ft. x 3/8 54, Crop/replace wasted door frame & install new 30 x 60 dogging door at Frame # 120, aft bulkhead. 6, Generator weighs a maximum of 25 tons and a safety factor of four is recommended to support diesel generator. Install four bolted padeyes from pair of transverse frames over diesel generator.. Suspend diesel generator from overhead with two 1 6 x ton x 25 nominal breaking strength classed bright wire shackled into existing 3/8 x 3 x 10 transverse frames pad eyes. Labor to suspend generator 15, Materials Two 1 6 x 19 IPS 51.7 ton x 25 bright wires with eyes in each end 6, Four 60 ton classed shackles Four 2 x 6 x 6 steel pad eyes welded to overhead frames 1, Crop/replace 500 sq. ft. of 3/8 steel deck within compartment after suspending Generator and repair of Inner Bottom Tank below 500 sq. ft x 3/8 150, Prime all new work with two coats INTERNATIONAL 300V epoxy prime (Labor & materials) 12, Return space(s) to original upon completion of repairs. 30, Task 17 $ 438,
90 TASKING ESTIMATED COST 19. VOID SPACE, D-99, Frames Tasking for D-99V This space is directly under the Aft Emergency Diesel Room and is in poor structural condition. All transverse and longitudinal frames shall be replaced, the fore and aft bulkheads shall be replaced and the keel shall be repaired. After removal of overhead deck plating complete the following: Clean/certification of spaces D-98F, D-95V and D-96V are safe for hotwork. $ 35, Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR 65, Crop/replace longitudinal plating (1/2 x 28L x 4 H) on #1 longitudinal 112 sq. ft x ½ 39, Crop/replace longitudinal plating (1/2 x 18 L x 4 H) on #2 longitudinal 112 sq. ft x ½ 39, Crop/replace longitudinal plating (1/2 x 18 L x 4 H) on #3 longitudinal 112 sq. ft x ½ 39, Crop and replace transverse plating (3/8 x 30 L x 4 H) on # 1 transverse 120 sq. ft x 3/8 36, Crop and replace transverse plating (3/8 x 30 L x 4 H) on # 2 transverse 120 sq. ft x 3/8 36, Crop and replace transverse plating (3/8 x 30 L x 4 H) on # 3 transverse 120 sq. ft x 3/8 36, Crop and replace transverse plating (3/8 x 30 L x 4 H) on # 4 transverse 120 sq. ft x 3/8 36, Crop and replace transverse plating (3/8 x 28 L x 4 H) on # 5 transverse 112 sq. ft x 3/8 33, Crop and replace transverse plating (3/8 x 28 L x 4 H) on # 6 transverse 112 sq. ft x 3/8 33, Crop and replace vertical flat plating of keel with new ¾ x 4 ½ x 28 long A-36 steel plate between Frames , Crop and replace diagonal support brackets (14) for keel with new ¾ A-36 steel plate; weld to new vertical keel plate and base of old flange between every transverse frame. 60 sq. ft. x ¾ 24, Crop out and replace both forward and aft bulkhead of tank with approx. 300 sq. ft of 3/8 A-36 steel plate. 300 sq. ft of 3/8 90, Prime all new work with two coats INTERNATIONAL 300V epoxy prime (Labor & materials) 16, Return space(s) to original upon completion of repairs. 30, Task 19 $ 629,
91 TASKING ESTIMATED COST ND PLATFORM & HOLD, TRIMMING TANK (D-12) & STOREROOMS OUTBOARD OF STEERING ROOM (D-25), Frames (cont.) Tasking D-12 The schedule of repairs in D-12 shall proceed as follows: Install adequate lighting for entire compartment. $ Install new ladders for forward and aft scuttles to safely access D-12 Trimming Tank. 1, Install framework for installing wood plank floor for footing and remove as repairs proceed from forward to aft 2, Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR for D-26P, D-26S & D-12 45, Crop and install new 3/8 steel bulkhead at Frame sq. ft. x 3/8 36, Install new 3/8 steel bulkhead at Frame sq. ft. x 3/8 66, Crop and replace vertical flat plating of keel with new ¾ x 4 ½ x 28 long A-36 steel plate between Frames sq. ft x ¾ 80, Replace five (5) centerline 6 O.D. ½ wall vertical stanchions (3 of 12, 1 of 11, 1 of 10 ) and tie into keelson plate and overhead frames. 60 ½ wall tube 12, Crop/replace longitudinal plating (1/2 x 28 L x 4 H) on #1 longitudinal. 112 sq. ft. x ½ 39, Crop/replace longitudinal plating (1/2 x 28 L x 4 H) on #2 longitudinal. 112 sq. ft x ½ 39, Crop/replace longitudinal plating (1/2 x 28L x 2 H) on #3 longitudinal, 70 sq. ft. x ½ 24, Crop/replace longitudinal plating (1/2 x 28L x 2 H) on #4 longitudinal, 70 sq. ft. x ½ 24, Crop/replace transverse plating (3/8 x 44 L x 2 H) on Frame 123 transverse 90 sq. ft x 3/8 31, Crop and replace transverse plating (3/8 x 44 L x 2 H) on Frame 124 transverse 90 sq. ft x 3/8 31, Crop/replace transverse plating (3/8 x 40 L x 2 H) on Frame 125 transverse 80 sq. ft x 3/8 28,
92 TASKING ESTIMATED COST ND PLATFORM & HOLD, TRIMMING TANK (D-12) & STOREROOMS OUTBOARD OF STEERING ROOM (D-25), Frames (cont.) Tasking D-12 (cont.) Crop/replace transverse plating (3/8 x 40 L x 2 H) on Frame 126 transverse 80 sq. ft x 3/8 $ 28, Crop/replace transverse plating (3/8 x 38 L x 2 H) on Frame 127 transverse 60 sq. ft x 3/8 26, Crop/replace transverse plating (3/8 x 38 L x 2 H) on Frame 128 transverse 60 sq. ft x 3/8 26, Remove shelving, components from D-26P & D-26S 20, Crop/replace floors in D-26P & D-26S 336 sq. ft. x 3/8 117, Install interior cofferdam plating between Transverse Frames 122 and 129 from overhead to keel to contain shell plate leaks. 1,680 sq. ft x ¼ 420, Prime all new work with two coats INTERNATIONAL 300V epoxy prime (Labor & materials) 18, Return space(s) to original upon completion of repairs. 30, Task 22 $ 1,150,
93 TASKING ESTIMATED COST ND PLATFORM & HOLD, TRIMMING TANK D-13, STEERING GEAR ROOM D-27, frames (cont.) Tasking D-27 For the purposes of cost estimating, the size of the hardware used to suspend the steering gear is approximated. The final method of removing the load of the steering gear from the structure beneath will require design by a licensed engineer. The schedule of repairs for D-27 is as follows: Install adequate lighting for entire compartment. $ Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR. 30, Crop and replace bottom 5 of plating on Transverse Frames throughout D-27with new 3/8 A-36 plating and match frame profiles 160 sq. ft x 3/8 plate 48, Suspend steering rams (100 tons) from overhead 3/8 x 4 x 10 channel transverse frames with four 1 ½ 6 x 19 classed bright improved plow steel IRWC wire with a nominal strength of 114 tons with a safety factor of four (4). Labor to suspend steering rams and components 28, Materials Four (4) 15 1 ½ 6 x 19 classed bright improved plow steel IRWC wire with eyes 11, Eight (8) classed 1 ½ shackles Eight 1 x 6 x 6 steel pads with 3 eyes to mount to overhead frames 3, Crop and replace bottom plating on Transverse Frames and base half frames under rudder crosshead with new 1/2 A-36 plating and match frame profiles 200 sq. ft. x 1/2 plate 70, Replace aft Bulkhead at Frame sq. ft. x ½ plate 31, Install 3 x 5 x ½ doubler plate under steering component forward 15 sq. ft x ½ plate 7, Upon suspension of steering gear, crop and replace deck throughout compartment with new ½ A-36 steel plate 672 sq. ft. of ½ plate 235, Prime all new work with two coats INTERNATIONAL 300V epoxy prime (Labor & materials) 15, Return space(s) to original upon completion of repairs. 10, Task 24 $ 491,
94 TASKING ESTIMATED COST nd PLATFORM VOID D-107, FRAMES 137 AFT PERPENDICULAR (cont.) Tasking D-107 The schedule of repairs for D-107 is as follows: Install adequate lighting for entire compartment. $ Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR. 30, Crop and replace plating on Transverse Frames throughout D-27with new 3/8 A-36 plating and match frame profiles 200 sq. ft x 3/8 plate 70, Crop out and replace three transverse bulkhead frames in base of compartment with new 3/8 A-36 plating and match frame profiles 140 sq. ft. x 3/8 plate 49, Install interior cofferdam plating between Transverse Frames 137 and 141 from overhead to keel to contain shell plate leaks. 800 sq. ft x ¼ plate 200, Install ¼ A-36 doubler plate over holed plating on transom above waterline. 300 sq. ft x ¼ plate 75, Prime all new work with two coats INTERNATIONAL 300V epoxy prime (Labor & materials) 15, Return space(s) to original upon completion of repairs. 10, Task 26 $ 449,
95 TASKING ESTIMATED COST 28. VOIDS D-101, D-102, D-103, FRAMES (cont.) Tasking D-101, D-102 & D-103 Install adequate lighting for entire compartment. $ Remediate all friable asbestos as required under 29 CFR 15, Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR 30, Crop and replace forty-eight (48) vertical stanchions through-out D-101, D-102 & D x 3/8 x 6 x 6 x 320 I-beams 67, Crop out and replace ninety-six (96) stanchion bases 1 steel pads throughout D-101, D-102 & D x 1 x 8 x 8 steel base plates 24, Crop out and replace wasted bulkheads at Frame # 134 & # sq. ft x 3/8 steel plate 180, Prime all new work with two coats INTERNATIONAL 300V epoxy prime (Labor & materials) 15, Return space(s) to original upon completion of repairs. 10, Task 28 $ 342,
96 TASKING ESTIMATED COST 30. THIRD DECK, CPO QUARTERS D-111, CPO MESS ROOM D-112, CPO PANTRY D Tasking D-111 Install adequate lighting for entire compartment. $ Remediate all friable asbestos as required under 29 CFR 15, Remediation of red lead where steel is to be cut 4 to either side of cut per 29 CFR 30, Replace five (5) centerline 6 O.D. ½ wall vertical stanchions 60 ½ wall tube 12, Crop out and replace ten (10) stanchion bases 1 steel pads in D-111 (10) 1 x 8 x 8 steel pads 3, Crop out and replace wasted bottom 3 bulkheads at Frame # 134 & # sq. ft. of 3/8 A-36 plate 111, Prime all new work with two coats INTERNATIONAL 300V epoxy prime (Labor & materials) 8, Tasking D-112 Task 30.1 $ 180, Install adequate lighting for entire compartment. $ Remediate all friable asbestos as required under 29 CFR 15, Crop/ replace three (3) 6 O.D. x ½ wall vertical stanchions in D-112 (3) 6 O.D. x ½ wall x 86 stanchions 7, Crop/replace six (6) stanchion bases 1 steel pads in D-111 (12) 1 x 8 x 8 steel pads 3, Crop/replace wasted bottom 3 bulkheads at Frame # sq. ft. of 3/8 A-36 plate 45, Prime all new work with two coats INTERNATIONAL 300V epoxy prime (Labor & materials) 8, Task 30.2 $ 80,
97 TASKING ESTIMATED COST 30. THIRD DECK, CPO QUARTERS D-111, CPO MESS ROOM D-112, CPO PANTRY D-113 (cont.) 30.3 Tasking D-113 Install adequate lighting for entire compartment. $ Remediate all friable asbestos as required under 29 CFR 10, Crop/ replace three (3) 6 O.D. x ½ wall vertical stanchions in D-112 (2) 6 O.D. x ½ wall stanchions 5, Crop/replace six (6) stanchion bases 1 steel pads in D-111 (4) 1 x 8 x 8 steel pads 1, Crop/replace wasted deck in C sq. ft. of 1/2 A-36 plate 20, Prime all new work with two coats INTERNATIONAL 300V epoxy prime (Labor & materials) 3, Task 30.3 $ 40,
Thickness measurement and close-up survey guidance
Working together for a safer world Thickness measurement and close-up survey guidance Part 2, Special survey requirements Other ship types & general dry cargo ships October 2014 Part 2 Special Survey Requirements
RECONSTRUCTION OF THE HISTORIC BATTLESHIP TEXAS
RECONSTRUCTION OF THE HISTORIC BATTLESHIP TEXAS William M. Hayden, P.E. 1 (M), Allen Pac 1 (M), Julius M. Taylor, III 2 (M) 1. Waller Marine, Inc. Houston, TX 2. Taylor Marine Construction, Inc. Beaufort,
Ship Structure Committee Case Study. BULK CARRIERS: Design, Operation, and Maintenance Concerns for Structural Safety of Bulk Carriers
Member Agencies: American Bureau of Shipping Defence Research and Development Canada Maritime Administration Military Sealift Command Naval Sea Systems Command Society of Naval Architects & Marine Engineers
M/V Eleranta IMO 9081198. Water Ballast Tank Inspection Report. China Shipping International Shipyard Co. Ltd (CSIS), Changxing Island, Shanghai
M/V Eleranta IMO 9081198 Water Ballast Tank Inspection Report China Shipping International Shipyard Co. Ltd (CSIS), Changxing Island, Shanghai 24 June 2010 Report prepared by: Andrew Cass Page 1 of 17
A.1 Obligations and reporting of the gaining Society. Plans to be Submitted by the Owner to the Gaining Society
(Rev.0 July 2009) (Rev.1 June 2012) (Rev.2 Oct 2013) (Rev.3 Jan 2015) (Rev.4 July 2015) (Rev.5 Jan 2016) Procedure for Transfer of Class TABLE OF CONTENTS Procedure for Transfer of Class Application Definitions
IACS Guidelines for Surveys, Assessment and Repair of Hull Structure Bulk Carriers
No.76 No.76 (1994) (Rev.1 July (cont) 2001) (Rev.2 June 2004) (Corr.1 Sept 2007) IACS Guidelines for Surveys, Assessment and Repair of Hull Structure Bulk Carriers Page 1 of 1 IACS Rec. 2004/Corr.1 2007
Simple Damage Control Aboard
Simple Damage Control Aboard By Marc A. Barredo Damage control aboard ship involves any prudent action that will; prevent or reduce expected damage to the ship, stabilize the situation caused by the damage,
MM 45 Charter Catamaran Subchapter "T" - 49 Passenger
MM 45 Charter Catamaran Subchapter "T" - 49 Passenger Make: MM 45 Charter Catamaran Model: Subchapter "T" - 49 Passenger Length: 45 ft Price: $ 600,000 Year: 2015 Condition: New Location: Portland, United
Repair of a Hull 15 m below the Waterline
Repair of a Hull 15 m below the Waterline Fig. 1 This 189 m vessel required an underwater repair after it had its hull pierced sufficiently enough to let seawater enter its water ballast tank. Since circumstances
VLCC Structural Design - Past, Present and Future
TSCF 2007 Shipbuilders Meeting VLCC Structural Design - Past, Present and Future Seong Ki Kim 1), Minsu Cho 2), Theodore W. Kang 3) Sungkon Han 4) and ManSoo Kim 5) 1) Hull Basic Design Team, DSME, Seoul,
Corrosion protection of crude oil cargo tanks new IMO regulations
Guidance note oil cargo tanks new IMO regulations Guidance for shipowners and operators, manufacturers and ship builders 1. Background to the new requirements Following incidents resulting from structural
Case Study 10 R/V WESTERN FLYER Chronic Cracking in an Aluminum SWATH Research Vessel
Case Study 10 R/V WESTERN FLYER Chronic Cracking in an Aluminum SWATH Research Vessel Vessel Particulars LOA: 117-3 5/8 Breadth: 53-0 Depth: 25-0 Draft: 12-0 Gross Tonnage: 499 Displacement: 419 LT Complement:
SECTION 15410 GROUND WATER STORAGE TANKS
SECTION 15410 GROUND WATER STORAGE TANKS PART 1 GENERAL.01 SCOPE A. Section Includes Requirements for designing, fabricating, and erecting a welded steel ground storage tank..02 SYSTEM DESCRIPTION A. Design
SECTION 14 20 10 - FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL
SECTION 14 20 10 - FREIGHT & PARKING GARAGE PART I - GENERAL 1.1 SECTION INCLUDES [NOTE to AE: The following lists requirements that are specific to freight elevators. These requirements are in addition
FIREFIGHTING AND DAMAGE CONTROL
FIREFIGHTING AND DAMAGE CONTROL Everyone on aboardship have another big job - to work aside from their primary duties. This big job is to look out constantly for the safety of the ship and crew. When the
Engineers at Liftech designed the structure of the first container crane and have designed and reviewed thousands of container cranes since.
Engineers at Liftech designed the structure of the first container crane and have designed and reviewed thousands of container cranes since. Liftech is the structural review engineer of record for most
A MATTER OF STABILITY AND TRIM By Samuel Halpern
A MATTER OF STABILITY AND TRIM By Samuel Halpern INTRODUCTION This short paper deals with the location of Titanic s Center of Buoyancy (B), Center of Gravity (G) and Metacenter Height (M) on the night
Structural Failures Cost Lives and Time
Structural Failures Cost Lives and Time Recent failures of storage bins, silos and other structures highlight the need to increase awareness of hazards associated with these structures. Since 2010, one
Pressure Vessel Assessment Report
Project Information Client: Total Energy Location: Blackwell OK Date: 7/23/2013 Contact: Integrity Mgmt. Advisor: Chuck Easterbrooks - API 510 #2212 Cc: API / UT Inspector: Robert Van Pelt-API 510# 40899
All Marine Solutions
All Marine Solutions PREMIUM MARINE MAINTENANCE, INSTALLATION AND REPAIR Marine Plumbing Marine Water Treatment Bow and Stern Thruster Fibreglass Gelcoat Timber Paint Work Marine Fit-outs SERVICE EXCELLENCE
The Original Carbon Fiber Reinforced Polymer System
Infrastructure The Original Carbon Fiber Reinforced Polymer System Phone: 52.292.39 Toll Free: 866.38.269 Fax: 52.48.5274 282 E. Fort Lowell Rd. Tucson, AZ 8576 www.dowaksausa.com Test results are supported
UNDERWATER MAINTENANCE AND REPAIR IN LIEU OF DRY DOCKING. USS MIDWAY Museum Installation of Hull Suction and Discharge Blank Patches
UNDERWATER MAINTENANCE AND REPAIR IN LIEU OF DRY DOCKING USS MIDWAY Museum Installation of Hull Suction and Discharge Blank Patches 1 Phoenix Who we are In Water Repair Capabilities The tool kit Hull Cleaning
STABILITY WHAT IS IT AND HOW DOES IT WORK?
STABILITY WHAT IS IT AND HOW DOES IT WORK? Eastland disaster, July 1915 Stability is the ability of a vessel to return to a previous position. Positive stability would then be to return to upright and
EAST LYME HIGH SCHOOL
Overview: 1971 N 1966 GYM 1966 CLASSROOM WING 1966 AUD. 1971 GYM 1998 1998 POOL EAST LYME HIGH SCHOOL Original 1966 Building: The original East Lyme High School was constructed in 1966 and was composed
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
MOBILE OFFSHORE UNITS
Guide for Building and Classing Mobile Offshore Units GUIDE FOR BUILDING AND CLASSING MOBILE OFFSHORE UNITS JULY 2008 (Updated February 2014 see next page) American Bureau of Shipping Incorporated by Act
CLASSIFICATION NOTES
CLASSIFICATION NOTES Type Approval, Installation and Testing of Water Level Detectors on Bulk Carriers and Single Hold Cargo Ships other than Bulk Carriers General Information This edition of the classification
Materials. Estimating Steel. Players. Materials. Shop Drawings. Detailing Process. Standard shapes. Fabricated members, Built-up sections
Materials Standard shapes W sections, C channels, Structural T, Angles, Pipes, Tubes, Rods and Plates Fabricated members, Built-up sections Adding plates to beam flanges, Stiffeners to beam webs Built
Owner s Manual Gantry Cranes
Owner s Manual Gantry Cranes Fixed Height Gantry Crane MODEL NUMBER: SERIAL NUMBER: CAPACITY IN TONS: Telescoping Gantry Crane Bushman AvonTec 262-790-4200, 800338-7810, Fax 262-790-4200 www.bushmanavontec.com
U.S.S. CHICAGO (CA29) Loss in Action. 29-30 January, 1943, Guadalcanal Island. Beam
U.S.S. CHICAGO (CA29) Loss in Action 29-30 January, 1943, Guadalcanal Island Class Heavy Cruiser Length (W.L.) 582 it. Launched 10 April, 1930 Beam r.,», 66 ft. Displacement. (Standard) 10,000 Tons Draft
Rehabilitation of an Aging Concrete Reservoir Adit Tower
Rehabilitation of an Aging Concrete Reservoir Adit Tower Raymond S. Tombaugh, Senior Coatings Consultant KTA-Tator, Inc. and Mongkol Mahavongtrakul, P.E. Corrosion Control Contract Manager San Francisco
SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
Safe & Sound Bridge Terminology
Safe & Sound Bridge Terminology Abutment A retaining wall supporting the ends of a bridge, and, in general, retaining or supporting the approach embankment. Approach The part of the bridge that carries
Drum Dispensing Stations
Drum Dispensing Stations O Safely Dispense from 55 Gallon Drums over a Spill Compliant Sump. 1-2-and 4 drum models available Drums are securely held on racks by galvanized positioners Sump and frame constructed
Boiler & Pressure Vessel Inspection discrepancies and failures
Boiler & Pressure Vessel Inspection discrepancies and failures Water Heaters / Pressure Vessels Pressure Vessels are inspected once every three years. This requires a test of A: safety relief devices B:
Emergency Response Plan. at sea also valid in case of Flooding, where applicable
Plan 1. Grounding, Stranding at sea also valid in case of Flooding, where applicable 2. Application Shorebased Organisation All Ships prepared: approved: released: Revision 0 HLS Management 2006-11-24
Module Title: General Ship Knowledge
CORK INSTITUTE OF TECHNOLOGY INSTITIÚID TEICNEOLAÍOCHTA CHORCAÍ Semester 1 FINAL Examinations 2009/10 School: National Maritime College of Ireland Programme Title: Bachelor of Science (Ordinary) in Nautical
Rudder and Rudder Horn Repair on the Bulk Freighter Sophia D
Rudder and Rudder Horn Repair on the Bulk Freighter Sophia D By Uwe W. Aschemeier and Kevin S. Peters The Island of Curacao is part of the Netherlands Antillean, located in the Caribbean Sea, just off
Stay Cable Replacement of the Luling Bridge
Stay Cable Replacement of the Luling Bridge Armin Mehrabi, Bridge Engineering Solutions, PC 2009 Louisiana Transportation Engineering Conference February 8-11, 2009, Baton Rouge, LA Lower Anchorage Upper
FRAME DOOR OPENING, DOOR AND SIDE PANEL OUTER
NUBIRA/LACETTI FRAME DOOR OPENING, DOOR AND SIDE PANEL OUTER 6 1 SECTION 6 FRAME DOOR OPENING, DOOR AND SIDE PANEL OUTER CONTENTS 1. FRAME DOOR OPENING........................................... 6 2 1.1.GENERAL
Part 0 - Classification and Surveys Classification and Surveys I-0 2016-01
Code Edition I - Ship Technology Part 0 - Classification and Surveys Classification and Surveys I-0 2016-01 Part 1 - Seagoing Ships Chapter 1 - Hull Structures I-1-1 2016-01 Chapter 1 - Hull Structures
H41 Electrical Stage Aft Air Conditioner Unit Installation
Aft Air Conditioner Unit Installation 1. Place Air-Cond unit in A/C shelf with air return facing fwd direction of the boat. 2. Do not secure Air-Cond Unit on shelf, install both side of air condition ABS
Use of Steel Grades for Various Hull Members - Ships of 90 m in Length and Above
(1978) (Rev.1 1980) (Rev.2 1996) (Rev.3 May 2002) Rev.4 July 2003) (Rev.5 Sept 2007) (Rev.6 May 2010) Use of Steel Grades for Various Hull Members - Ships of 90 m in Length and Above.0 Application This
DOCKMASTER TRAINING MANUAL
DOCKMASTER TRAINING MANUAL By HEGER DRY DOCK, INC. June, 2005 DOCKMASTER S TRAINING SEMINAR TABLE OF CONTENTS LECTURE NOTES SECTION 1 DRY DOCK TYPES Page 1.1 Basin Dry Docks... 1-2 1.2 Floating Dry Docks...
SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
INSTALLATION MANUAL. Installation Instructions
INSTALLATION MANUAL Power-Pole Signature Series Shallow Water Anchor Installation Instructions CAUTION: Read this instruction manual carefully. Become familiar with the controls and know how to operate
CLASSIFICATION SYSTEM BY FIELD AND SUB-FIELD OF EXPERTISE SUPPLIERS REGISTRY OF GOODS AND SERVICES ENAP GROUP OF COMPANIES I. Suppliers are classified in three groups: Classification Equipments, materials
External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902
External Wrapping of Steel Riser Pipe Case Study HJ3 CS200902 Introduction Refineries process a wide variety of petroleum products. As part of the process, they rely on cooling towers, which recycle water
Thickness measurement and close-up survey guidance
Working together for a safer world Thickness measurement and close-up survey guidance Part 1, Thickness measurement process October 2014 Contents Part 1 Part 1 Thickness Measurement Process Chapter 1 Introduction
INSTALLING SEISMIC RESTRAINTS FOR MECHANICAL EQUIPMENT
VISCMA 412/August 2014 INSTALLING SEISMIC RESTRAINTS FOR MECHANICAL EQUIPMENT August 2014 Developed originally by the Vibration Isolation and Seismic Control Manufacturers Association under a cooperative
STRUCTURAL ASSESSMENT REPORT BOLINAS MARINE STATION - BOLINAS, CALIFORNIA
STRUCTURAL ASSESSMENT REPORT BOLINAS MARINE STATION - BOLINAS, CALIFORNIA College of Marin c/o Swinerton Management & Consulting P.O. Box 144003 835 College Avenue, Building MS-3 Kentfield, California
Residential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13
STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13 (See Supplemental Instructions for trailers with heavy duty round footplates and/or Power Leveling Systems) PHONE SUPPORT
Report on Sanctuary/Chancel Crawl Space Inspection. St. John in The Wilderness, 2896 Old Lakeshore Road Bright s Grove. Project No.
Report on Sanctuary/Chancel Crawl Space Inspection St. John in The Wilderness, 2896 Old Lakeshore Road Bright s Grove Project No. E112056 1. Background St. John in the Wilderness (SJITW) is considering
Rudder Repair and refinish
Rudder Repair and refinish Montgomery 23 Dauntless The before photograph A receipt found inside the boat showed a previous owner had enlisted a boat yard to perform maintenance on the rudder by shortening
CODES OF PRACTICE. What one needs to know concerning regulations REGULATION
What one needs to know concerning regulations CODES OF PRACTICE Many yachts that are registered in London, Southampton, Guernsey or Gibraltar, and fly the British flag, call Italian and French Riviera
1 of 9 REPORT OF A CONDITION SURVEY CARRIED OUT ON THE VESSEL: Fxxxxxxxxx
1 of 9 Aidan Tuckett B.Sc.(Hons). MARINE SURVEYOR Accredited Member of the Yacht Designers and Surveyors Association REPORT OF A CONDITION SURVEY CARRIED OUT ON THE VESSEL: Fxxxxxxxxx 2 of 9 CONTENTS.
Transportation and Lifting of Liquefied Gas Dewars
Transportation and Lifting of Liquefied Gas Dewars FN000475/OJ 1 Fermilab uses liquefied gasses or cryogenics in various forms around the lab. These liquefied gasses are sometimes transported in large
Calvert USA, Inc. Attic Stairs
Calvert USA, Inc. Attic Stairs Instructions for installation of vertical opening access stairs Model numbers: 7035 through 7047 Calvert USA, Inc., P.O. Box 841, Solomons, MD 20688, Tel. (410) 286-1430,
What is Seismic Retrofitting?
What is Seismic Retrofitting? SEISMIC RETROFITTING A Seismic Retrofit provides existing structures with more resistance to seismic activity due to earthquakes. In buildings, this process typically includes
AIR RELEASE, CLEANOUT, AND SEWER MANHOLES
AIR RELEASE, CLEANOUT, AND SEWER MANHOLES **From Hartford IM BLDG(10) DESCRIPTION. This work shall consist of the construction of air release, cleanout, and sanitary sewer manholes; and the furnishing
Carefully to Carry. There is a common failure to fully understanding the strength limits of tank tops, tween decks, hatchcovers and weather-decks
UK P&I CLUB Carefully to Carry SEPTEMBER 2006 Preparing cargo plans structural limitations There is a common failure to fully understanding the strength limits of tank tops, tween decks, hatchcovers and
Walking and Working Surface Checklist:
Walking and Working Surfaces Purpose: This information is presented to improve the level of safety in our operations, and to inform you that we will comply with the OSHA Standard 29 CFR 1910.23. Responsibility:
The Stabilizer TM. Benefits. www.griptite.com. Supplemental support system for sagging beams and floor joists within a crawl space
The Stabilizer TM Supplemental support system for sagging beams and floor joists within a crawl space Pre-drilled holes in steel plate allow for connection to beam or floor joists. Benefits Levels and
TARIFF CODE and updates standard
TARIFF CODE and updates standard No HS CODE AHTN CODE PRODUCT DESCRIPTION PRODUCT TYPE STANDARDS IDENTIFIED 7207 Semi finished products of iron or non alloy steel Containing by weight less than 0.25% of
Annex 4: FRP CONSTRUCTION STANDARDS*
Annex 4: FRP CONSTRUCTION STANDARDS* 1.1 Definitions For the purpose of these recommendations, unless expressly provided otherwise, the following definitions apply: 1.1.1 readth ()** is the maximum breadth
Designed and Engineered to Perform
History EARTH CONTACT PRODUCTS, L.L.C., is a family owned company, based in Olathe, Kansas. This company was built upon Don May s U.S. Patented fourth-generation Steel Piering System that has led to the
Active and Passive Sash Replacement
for Andersen Gliding Windows Read all instructions carefully before attempting this procedure. If you have any questions about your ability to complete the procedure, call Andersen at 1-888-888-7020 for
ATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing
1 Most basements show some signs of leaking and cracking. Through the years, problems with water, poor soils, grading, drainage and possible settling affect the integrity of a basement. Being able to recognize
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
SECTION 15140 - PIPE HANGERS AND SUPPORTS
Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the
INSTALLATION. General. Important Note. Design. Transport
General The roof trusses you are about to install have been manufactured to precise engineering standards. To ensure that the trusses perform as designed, it is essential that they be handled, erected
CONTAINMENT BOOM OBJECTIVE & STRATEGY TACTIC DESCRIPTION. Mechanical Recovery Containment and Recovery
Mechanical Recovery Containment and Recovery CONTAINMENT BOOM OBJECTIVE STRATEGY ing is a fixed- tactic. The objective is to corral spilled oil on the water, usually near the source, thus minimizing spreading
4.3.5 - Breakaway Walls
4.3.5 - Breakaway Walls Elevation of a structure on a properly designed foundation reduces the potential for water damage from flooding. When the space below the lowest elevated floor is maintained free
12 November 2008 *** I:\CIRC\MEPC\01\642.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR
INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: 020 7735 7611 Fax: 020 7587 3210 IMO E Ref. T5/1.01 MEPC.1/Circ.642 12 November 2008 2008 REVISED GUIDELINES FOR SYSTEMS
COMMERCIAL REPORT / STOCK CONDITION SURVEY. Sydenham Hill Estate Sydenham Hill London SE 23
COMMERCIAL REPORT / STOCK CONDITION SURVEY For Sydenham Hill Estate Sydenham Hill London SE 23 Submission Prepared by Gas Advisory Services Limited Date: 4 th June 2013 Gas Advisory Services Limited Phoenix
Roof Condition Analysis
Roof Condition Analysis Prepared for: J.W. Nelson John Evans Middle School - Gym Dome 2900 15th Avenue Greeley, Colorado Prepared by: Gregory Ham Coastal Specified Products 5252 Sherman Street Denver,
University of Iowa Main Power Plant 2008 Flood Preparations, Event, & Recovery
University of Iowa Main Power Plant 2008 Flood Preparations, Event, & Recovery Yellow Alert for Mayflower Residence hall Peak at 31.5 feet Power Plant floods from steam tunnel and shuts down 1993 Flood
CODE OF SAFETY FOR CARIBBEAN CARGO SHIPS CCSS CODE
CODE OF SAFETY FOR CARIBBEAN CARGO SHIPS (Cargo Ships less than 500 Gross Tonnage) CCSS CODE CARIBBEAN MEMORANDUM OF UNDERSTANDING ON PORT STATE CONTROL SECRETARIAT BARBADOS FORWORD The Code of Safety
US 51 Ohio River Bridge Engineering and Environmental Study
US 51 Ohio River Bridge Engineering and Environmental Study ITEM NOS. 1-100.00 & 1-1140.00 Prepared by: Michael Baker Jr., Inc. 9750 Ormsby Station Rd Louisville, KY 40223 August 16, 2013 Table of Contents
National Transportation Safety Board
National Transportation Safety Board Marine Accident Brief Allision of Bulk Carrier Anna Smile with Louis Dreyfus Grain Elevator Accident no. Vessel name Accident type Location DCA14LM013 Anna Smile Allision
GENERAL OCEAN TOW RECOMMENDATIONS FOR JACKUP DRILLING UNITS International Association of Drilling Contractors (I.A.D.C.) February 13, 1991
GENERAL OCEAN TOW RECOMMENDATIONS FOR JACKUP DRILLING UNITS International Association of Drilling Contractors (I.A.D.C.) February 13, 1991 Manning 1. Manning should comply with U.S. Coast Guard regulations
Basic terms deck engine room propeller shaft bow thruster rudder bulbous bow hold
Unit 1 SHIPS AND SHIPS TERMS SHIP DESIGN AND CONSTRUCTION (general introduction) hull superstructure machinery stern bow amidships beam Basic terms deck engine room propeller shaft bow thruster rudder
Metal Boat Building Structural Details
Metal Boat Building Structural Details Chris Barry IBEX 2003 Session 505 9:00 AM February 7, 2003. Introduction Goals God is in the Details Miles Van Der Rohe Scantling Determination / Optimization Action
Photo 2. View showing flour mill, machine shed, veranda and saw mill + storage shed.
May 7,2015 KSANDER & ASSOCIATES CONSULTING PROFESSIONAL ENGINEERS 130 HUINTER STREET, UNIT 103, PETERBOROUGH, ONTARIO K9H2K8 TELEPHONE (705) 743-9221 FAX 743-0904 Ontario Region Conservation Authority
Livorsi DTS Controls Single/Dual Engine Digital Throttle & Shift Installation
715 Center Street Grayslake IL 60030 P: 847-752-2700 F: 847-752-2415 E: [email protected] Livorsi DTS Controls Single/Dual Engine Digital Throttle & Shift Installation NOTICE This document is written to
Statistical Summary Marine Occurrences 2013
Statistical Summary Marine Occurrences 2013 Foreword This document provides Canadians with an annual summary of selected maritime safety data. It covers commercial vessels, which include all vessels registered
INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Requirements concerning MOORING, ANCHORING AND TOWING
INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES Requirements concerning MOORING, ANCHORING AND TOWING CONTENTS Equipment Rev.5 June 2005 A2 Shipboard fittings and supporting hull structures associated
National Transportation Safety Board
National Transportation Safety Board Marine Accident Brief Fire On Board Motor Yacht Ocean Alexander 85E06 Accident no. Vessel name Accident type Location DCA13LM029 Ocean Alexander 85E06 Fire Date July
Modular Locomotive System Instruction Manual for HBK8 George Body Kit
Modular Locomotive System Instruction Manual for HBK8 George Body Kit Roundhouse Engineering Co. Ltd. Units 6-10 Churchill Business Park. Churchill Road, Wheatley. Doncaster. DN1 2TF. England. Tel. 01302
Cuyahoga County s Clean Ohio Revitalization Fund Round 5 Application Great Lakes Shipyard Expansion Project Attachment A1 Application Summary Document
Cuyahoga County s Clean Ohio Revitalization Fund Round 5 Application Great Lakes Shipyard Expansion Project Attachment A1 Application Summary Document A1-1 ATTACHMENT A1 Great Lakes Shipyard Expansion
March 19, 2014. Ms. Jean McDonald CAP Management 910 16th Street, Suite 1010 Denver, Colorado 80202
Ms. Jean McDonald CAP Management 910 16th Street, Suite 1010 Denver, Colorado 80202 Re: Prospector s Point Walkway/Façade Repairs Martin/Martin, Inc Project No.: 13.0358.S.02 Ms. McDonald: Per your request
METHOD OF STATEMENT FOR STATIC LOADING TEST
Compression Test, METHOD OF STATEMENT FOR STATIC LOADING TEST Tension Test and Lateral Test According to the American Standards ASTM D1143 07, ASTM D3689 07, ASTM D3966 07 and Euro Codes EC7 Table of Contents
Originators of the Flexible Water Tube design
BRYAN FLEXIBLE WATER TUBE AB SERIES STEAM AND WATER BOILER 900,000 TO 3,000,000 BTUH FORCED DRAFT GAS, OIL OR DUAL FUEL FIRED Water Boiler AB120-W-FDGO Steam Boiler AB250-S-150-FDG Originators of the Flexible
The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm:
Page 1 of 6 Section 1. PURPOSE This policy is an Engineering checklist of the Local Review Program for sanitary sewer improvement projects by the Bedford Regional Water Authority ( Authority ). Section
Stilling Well Recommendations
White Paper June 24, 2009 Stilling Well Recommendations This document describes general requirements for stilling wells used for radar tank gauging applications. Automation solutions for oil & gas, defense
