1 Desalination Dossier
2 Water for human progress
3 Desalination Dossier References of Reverse Osmosis Plants
4 Name of the Plant (Country) Client Water type and Treatment Capacity (CMD - MGD) Final Use Year of Operation DB O&M DBOO Jorf Lasfar (Morocco) OCP SW DAF+UF+RO 75, MGD Industrial UC Granadilla (Spain) Gobierno de Canarias SW RO 14, MGD UC Al-Zawrah (United Arab Emirates) FEWA SW DAF+UF+RO 45, MGD 2015 Al Ghubrah (Oman) OPWP SW DAF+RO 191, MGD 2015 X 20 years Ceuta III (Spain) MARM SW RO 10, MGD 2014 El Morro (Chile) GoldCorp. Inc. SW DAF+UF+RO 64, MGD Industrial 2012 E Águilas-Guadalentín (Spain) ACUAMED SW RO 210, MGD Irrigation years Rincón de León (Spain) EPSAR SS UF+UVD+RO 25, MGD Irrigation years La Llagosta (Spain) AGBAR BW RO 12, MGD 2010 Sant Joan Despí (Spain) AGBAR BW UF + RO 206, MGD 2010 La Aldea (Spain) Consejo Insular de Aguas de Gran Canaria SW RO 5, MGD years Campo de Dalías (Spain) ACUAMED SS MF + RO 12, MGD Irrigation 2008 Dhekelia IV Refurbishment and Extension (Cyprus) Caramondani Desalination Plants SW RO 60, MGD 2008 EPM Los Jameos (Spain) Los Jameos, S.L. SW RO MGD year Valdelentisco (Spain) ACUASEGURA SW RO 200, MGD Irrigation years Dhekelia III Refurbishment (Cyprus) Caramondani Desalination Plants SW RO 40, MGD 2007 EPM Melilla (Spain) MMA SW RO 20, MGD 2007 X 12 years Rincón de León (Spain) EPSAR SS UF + RO 25, MGD Irrigation years Madinat Yanbu (Saudi Arabia) Royal Commission for Jubail and Yanbu SW RO 50, MGD 2006 EPM Hotel HL Paradise (Spain) Isla del Paraíso, S.L. SW RO MGD years Alicante I &II (Spain) MMA SW RO 65, MGD II I X 15 years Ceuta I & II (Spain) ACEMSA MOPTMA SW RO 23, MGD II 2004 I X 4 years 30 years
5 Name of the Plant (Country) Client Water type and Treatment Capacity (CMD - MGD) Final Use Year of Operation DB O&M DBOO Formentera I & II (Spain) Ministerio de Fomento MMA SW RO 4, MGD II I years & 9 months Hotel Costa Calero (Spain) Costa Canaria, S.A. SW RO MGD years Hotel Timanfaya (Spain) Playa Blanca 2000, S.A. SW RO MGD years Hotel Calimera (Spain) Calimera Aktivhotels SW RO MGD years Zarzis I & II - (Tunisia) SONEDE BW RO 15, MGD II I year Jerba I & II - (Tunisia) SONEDE BW RO 15, MGD II I year San Nicolás de Tolentino (Spain) Consejo Insular de Aguas de Gran Canaria SW RO 5, MGD years & 10 months Sta. Cruz Tenerife (Spain) MMA SW RO 20, MGD years & 4 months Oliva Beach (Spain) Riusa II, S.A. SW RO MGD years Dhekelia I & II (Cyprus) Caramondani Desalination Plants SW RO 40, MGD II I EPM Agragua I & II (Spain) AGRAGUA, S.A. SW RO 15, MGD Irrigation II I X 22 years Ibiza (Spain) Gobierno de las Islas Baleares SW RO 9, MGD years & 4 months Bajo Almanzora (Spain) Junta de Andalucía BW NF 30, MGD year Hotel Lanzarote Park (Spain) Costa Los Limones SW RO MGD years Hotel Riu Paraíso (Spain) Riusa II, S.A. SW RO MGD years Galdar (Spain) Ayuntamientos de Galdar y Agaete SW RO 3, MGD 1989 X 8 years La Oliva I (Spain) Suministros de Agua La Oliva, S.A. SW RO 1, MGD year Costa Lanzarote (Spain) Costa Lanzarote Promociones, S.A. SW RO MGD years Lanzarote II (Spain) MOPU SW RO 7, MGD 1986 LEGEND: Type of Water and Treatment: SW Seawater MF Microfiltration BW Brackish Water SS Secondary Sewage RO Reverse Osmosis UF Ultrafiltration NF Nano-filtration DAF Dissolved air flotation Capacity: 1 MGD 3,785 CMD (m 3 /d) Year of Operation: UC Under Construction Type of Contract: DBOO: Design, Build, Own and Operate (or BOOT) DBO: Design, Build and Operate (or + O&M) DB: Design and Build (or / EPM). : Engineering, Procurement and Construction (Turn-Key). EPM: Engineering, Procurement and Management (Main Subcontractor without construction) O&M: Operation and Maintenance Contract E: Engineering
6 SWDP Jorf Lasfar MOROCCO Capacity: 75,800 m 3 /day (20 MGD) Type of treatment: DAF+UF+RO Year of operation: Under construction cadagua
7 Client: Location: Capacity: Raw water: Use: Contract type: Office Chérifien des Phosphates (OCP) Jorf Lasfar (Morocco) 75,800 m 3 /d - (20 MGD) Seawater TDS=37,000 mg/l Industrial/ Process Description Process Line Main Equipment SEAWATER COLLECTION 2+1 Horizontal centrifugal pumps PRE-TREATMENT 5+1 DAF 3+1 Coarse bar screens with 15 mm openings 3+1 Self-cleaning fine screens with 3 mm openings 5+1 Horizontal centrifugal pumps supplying UF 3+1 Self-cleaning mesh filters 20 UF racks 2 Ultrafiltered water tank, 1,000 m Horizontal centrifugal filtered water pumps 16 Cartridge filters with 5 m selectivity 1 Dosing system: sodium hypochlorite, ferric chloride, dispersant, and sodium bisulphite, sulphuric acid and sodium hydroxide UNDER CONSTRUCTION REVERSE OSMOSIS 5+1 Booster pumps 5+1 High pressure horizontal pumps 5+1 Energy recovery systems using pressure exchangers 5+1 High pressure booster pumps st stage RO Racks x 16,114 m 3 /d 5+1 Feed pumps to 2 nd stage nd stage RO Racks x 5,360 m 3 /d 1 Membrane cleaning system 1 Permeate tank, 200 m 3 POST-TREATMENT 1 Dosing systems: calcium hydroxide, CO 2 and sodium hydroxide PRODUCT WATER PUMPING 2+1 Horizontal centrifugal pumps PRODUCT WATER STORAGE 2 Tanks, 5,000 m 3 WASTEWATER TREATMENT 1 Treatment plant of the effluents generated at the facility Desalination Dossier
8 SWDP Granadilla SPAIN Capacity: 14,000 m 3 /day (3.69 MGD) Type of treatment: RO Year of operation: Under Construction cadagua
9 Client: Location: Capacity: Raw water: Use: Contract type: Gobierno de Canarias Tenerife (Spain) 14,000 m 3 /day (3.69 MGD) Seawater - TDS = 38,600 mg/l Process Line Process Description Main Equipment SEAWATER INTAKE 6+2 Submersible Pump, m 3 /h at 60 m 1+1 Diaphragm metering pump PRE-TREATMENT 2 Air scouring blowers, Nm 3 /h/unit 3 Sand bed horizontal DM gravity filters 3 Dispersant, sodium bisulphite and ferric chloride dosing systems 2+1 Selectivity cartridge filters, µ5 m REVERSE OSMOSIS 2+1 High pressure pumps 16 Pressure Exchange Chambers 2 Booster Pumps 2 7 elements racks X 7,700 m 3 /day, conversion 40% 1 membranes displacement and cleaning system UNDER CONSTRUCTION POST-TREATMENT 3 Hydroxyde, CO2 and sodium hypochlorite dosing systems PRODUCT WATER PUMPING 2+1 Multistage Pumps, 390 m 3 /h at 228 m 2+1 Multistage Pumps, 225 m 3 /h at 165 m PRODUCT WATER STORAGE 1 Double glass regulator tank, 7,000 m 3 Desalination Dossier
10 SWDP Al-Zawrah UNITED ARAB EMIRATES Capacity: 45,500 m 3 /day (12 MGD) Type of treatment: DAF+UF+RO Year of operation: 2015 cadagua
11 Client: Location: Capacity: Raw water: Use: Contract type: Federal Electricity & Water Authority (FEWA) Ajman (United Arab Emirates) 45,500 m 3 /day (12 MGD) Seawater - TDS = 42,000 mg/l Process Description Process Line Main Equipment SEAWATER INTAKE 5 Centrifugal pumps, 1,240 m 3 /h, 315 kw, 15 mwc with DAF-47 mwc without DAF 2 Intake screens PRE-TREATMENT 2 Pre-chlorination system 4 Floculation and DAF units 3 DAF recirculation pumps 5 UF feed pumps, 1,238 m 3 /h, 250 kw, 37 mwc 3 Self cleaning filters 14 UF racks x 5,015 m 3 /h, conversion ratio 95,38%, PENTAIR Seaflex 100 No. of modules per train 2 UF backwash pumps 1 UF backwash tank, 150 m 3 2 UF air scour YEAR OF OPERATION: 2015 REVERSE OSMOSIS 4 High pressure pumps, 488 m 3 /h unit capacity, 1,400 kwe, 627 mwc, KSB 4 RO racks x 11,480 m 3 /h, conversion factor 40%, Toray 100 No. of modules per train 4 Energy recovery systems, 13 modules of Pressure exchangers ERI PX Flushing system 1 Cleaning system POST-TREATMENT 2 Post-chlorination system EFFLUENT TREATMENT 1 Flushing system Desalination Dossier
12 SWDP Al Ghubrah OMAN Capacity: 191,000 m 3 /day (50.4 MGD) Type of treatment: DAF+RO Year of operation: 2015 cadagua
13 Client: Location: Capacity: Raw water: Use: Contract type: Oman Power and Water Procurement Company (OPWP) Al Ghubrah (Oman) 191,000 m 3 /day (50.4 MGD) Seawater - TDS = 37,000-45,000 mg/l DBOO (O&M 20 years) Process Description Process Line Main Equipment SEAWATER INTAKE 2 Intake Pipes (1.5 km each) 3+1 Vertical pumps 4 Passive screens PRE-TREATMENT 7+1 DAF 7+1 Horizontal centrifugal pumps supplying DMF 52 Dual media filters (DMF) REVERSE OSMOSIS 16 Cartridge filter vessels with 5 µm selectivity 1 Dosing system: sodium hypochlorite, ferric chloride, sodium silicofluoride, antisclant, sodium bisulphite, sulphuric acid and sodium hydroxide 7+1 High pressure horizontal pumps 7+1 Energy recovery systems using pressure exchangers 7+1 High pressure booster pumps st pass RO Racks x 30,536 m 3 /d 7+1 Feed pumps to 2nd pass nd pass RO Racks x 16,911 m 3 /d 1 RO Membrane cleaning system YEAR OF OPERATION: 2015 POST-TREATMENT 1 Dosing systems: calcium hydroxide, CO 2 and sodium hypochlorite PRODUCT WATER PUMPING 2 Product water tanks, 2x200 m Horizontal centrifugal pumps EFFLUENT TREATMENT PLANT 3+1 Centrifuges (dewatering of DAF solids) WASTEWATER TREATMENT 1 Treatment plant for the wastewater generated at the facility Desalination Dossier
14 SWDP Ceuta III SPAIN Capacity: 10,000 m 3 /day (2.64 MGD) Type of treatment: RO Year of operation: 2014 cadagua
15 Client: Location: Capacity: Raw water: Use: Contract type: Ministerio de Medio Ambiente, y Medio Rural y Marino (MARM) Ceuta (Spain) 10,000 m3/d (2.64 MGD) Seawater - TDS = 39,800 mg/l Process Description Process Line Main Equipment SEAWATER INTAKE 2+1 Horizontal Centrifugal pumps PRE-TREATMENT 3 Sand filters 5 Sodium hypochlorite, Ferric chloride, sulfuric acid, antiscalant and sodium bisulphite dosing systems 2+1 Cartridge filters HIGH-PRESSURE PUMPING 2 Driving engines 3+1 Booster Pumps 2+1 High pressure Pumps 2 Booster Pumps YEAR OF OPERATION: 2014 REVERSE OSMOSIS 2 RO Racks x 5,000 m 3 /day, FILMTEC SW30HR RO Racks, 2 stages - FILMTEC Recovery rate: 90% 1 Sodium hydroxide dosing system CHEMICAL CLEANING 1 Chemical cleaning device POST-TREATMENT 2 Sodium hypochlorite and lime dosing systems PRODUCT WATER PUMPING 2+1 Centrifugal pumps EFFLUENT TREATMENT 1 Backwashing treatment device 2 Submergible pumps 1 Sludge thickening device 1 Neutralization system Desalination Dossier
16 SWDP El Morro CHILE Capacity: 64,000 m 3 /day (16.89 MGD) Type of treatment: DAF+UF+RO Year of completion: 2012 cadagua
17 Client: Location: Capacity: Raw water: Use: Contract type: GoldCorp Inc. Punta Cachos (Chile) 64,000 m 3 /day (16.89 MGD) Seawater TDS=35,337 mg/l Industrial/ E Process Description Process Line Main Equipment PRE-TREATMENT 5+1 DAF 5+1 Horizontal centrifugal pumps supplying UF 11+1 Self-cleaning disc filters 10+1 UF racks 1 Ultrafiltered water tank, 250 m Horizontal centrifugal filtered water pumps 9 Cartridge filters with 5 m selectivity REVERSE OSMOSIS 5+1 High pressure horizontal pumps 1 Dosing system: sodium hypochlorite, ferric chloride, antiscalant, and sodium metabisulphite, sulphuric acid and caustic soda 5+1 Energy recovery systems using pressure exchangers 5+1 High pressure booster pumps st stage RO Racks x 12,917 m 3 /d 1 Membrane cleaning system YEAR OF COMPLETION: 2012 POST-TREATMENT 1 Dosing systems: calcium hydroxide and carbon dioxide PRODUCT WATER TRANSFER PUMPING 2+1 Horizontal centrifugal pumps WASTEWATER TREATMENT 1 Neutralization tank, 200 m 3 Desalination Dossier
18 SWDP Águilas - Guadalentín SPAIN Capacity: 210,000 m 3 /day (55.48 MGD) Type of treatment: RO Year of operation: 2012 cadagua
19 Client: Location: Capacity: Raw water: Use: Contract type: Aguas de las Cuencas Mediterráneas, S.A. (ACUAMED) Murcia (Spain) 210,000 m 3 /day (55.48 MGD) Seawater - TDS = 39,700 mg/l /Irrigation + O&M (15 years) Process Description Process Line Main Equipment SEAWATER INTAKE Open Sea Intake Seawater Intake Pipe 1 L= 870 m, DN-2000 HDPE seabed laid pipe, capacity 20.4 ML/h Seawater Intake Pumping St. 6+1 Submersible Centrifugal Pumps, 4,090 m 3 /h at 48 m, 760 kw. PRE-TREATMENT 2 Stage Dual Media Filtration First Step Filtration 20 DM Gravity Filters, 200 m 2 /ud 1st Filters Backwashing System 2+1 Backwashing water pumps / Air scouring blowers Intermed. Filtered water Pumping 12+1 Centrifugal Pumps Second Step Filtration 44 DM Pressure Filters, 3.6 m diam x L = 13 m 2nd Filters Backwashing System 2+1 Backwashing water pumps / Air scouring blowers Reactive Dosing Antiscalant, sodium bisulphite, sodium carbonate, sodium hypochlorite, coagulant, polyelectrolyte, sulfuric acid and ferric chloride dosing systems. YEAR OF OPERATION: 2012 REVERSE OSMOSIS Fine Filtration 24 Cartridge filters Reactive Dosing 4 Sulphuric acid, sodium bisulphite, antiscalant and sodium hydroxide Booster Pumping Station 12 Centrifugal Pumps 700 m 3 /h at 120 m, 315 kw High Pressure Pumping Station 12 Centrifugal Pumps, 700 m 3 /h at 605 m, 1,550 kw RO Racks 1st Pass 12 RO Racks x 16,800 m 3 /day, Recovery rate 45%, 190 pressure vessels, 7 elements/ vessel. Filmtec SW 30HR LE400i Energy Recovery Devices 36 Pressure Exchange devices - DWEER Energy Recovery Pumping 12 Centrifugal Pumps, 840 m 3 /h at 47 m, 160 kw Pumping Feed Second Pass 4 Centrifugal Pumps, 1,500 m 3 /h at 127 m, 750 kw RO Racks 2nd Pass 5 RO Racks x 25,000 m 3 /d, Recovery rate 90%, 138 pressure vessels, 7 elements/ vessel DOW. Filmtec LE440i Chemical Cleaning and Flushing 2 Tank + pumps for cleaning and neutralization POST- TREATMENT 1 Calcium contact bed and CO 2 for LSI and SA adjustment. Product Pumping Station Centrifugal pumps EFFLUENT TREATMENT 1 Clarification of backwash effluent, thickening & dewatering of sludge 1 ph adjustment of wasted cleaning chemical solution 1 Sodium Hypochlorite dosing system Desalination Dossier
20 WWTP Rincón de León SPAIN Capacity: 50,000 m 3 /day (UF) (13.21 MGD) 8,800 m 3 /day (UVD) (2.12 MGD) 25,700 m 3 /day (RO) (6.77 MGD) Type of treatment: UF + UVD + RO Year of operation: 2010 cadagua
21 Client: Location: Entidad Pública de Saneamiento de Aguas Residuales de la Comunidad Valenciana (EPSAR) Alicante (Spain) (I) ULTRAFILTRATION Capacity: 50,000 m 3 /day Raw Water: SS Effluent Conductivity: 3,500 µs/cm (II) UV DISINFECTION Capacity: 8,800 m 3 /day Raw Water: SS Effluent Conductivity: 3,500 µs/cm (III) REVERSE OSMOSIS Capacity: 25,700 m 3 /day Raw Water: Ultrafiltrated water Conductivity 3,500 µs/cm Use: Contract type: Irrigation + O&M Process Line Process Description Main Equipment PRE-TREATMENT 2 Lines of mixing and flocculation chambers, m 3 /line 60 Sand filters. Continuous washing 3 Protection filters 6 Ultrafiltration cassettes, 60 modules/cassette UV DISINFECTION 1 UV radiation system, 32 lamps 6 Ferric chloride, polyelectrolyte, nitric acid, sodium hypochlorite, sodium bisulphite and sodium hydroxide dosing systems. 2 Submersible pumps YEAR OF OPERATION: 2010 REVERSE OSMOSIS 5 Feed pumps 5 Cartridge filters 3 RO Racks - TRISEP 8040-X201-TSA 2 Two Staged RO Racks - Filmtec BW /34i 2 Antiscalant and sulfuric acid dosing systems 3 Blending pumps 5 Booster pumps CHEMICAL CLEANING 1 Chemical cleaning equipment NEUTRALIZATION 1 Neutralization system ENERGY RECOVERY DEVICES 2 Energy recovery devices Desalination Dossier
22 BWDP La Llagosta SPAIN Capacity: 12,960 m 3 /day (3.42 MGD) Type of treatment: RO Year of operation: 2010 cadagua
23 Client: Location: Capacity: Raw water: Use: Contract type: Sociedad General de Aguas de Barcelona (AGBAR) Barcelona (Spain) 12,960 m 3 /day (3.42 MGD) Brackish water - TDS=1,254 mg/l. Process Description Process Line Main Equipment INTAKE Intake pumping from Donadeu Well 1 Submersible Pump (from deep well), 540 m 3 /h at 10 mlc 75 kw Intake pumping from Montcada-Regants Well 1 Submersible Pump (from deep well), 180 m 3 /h at 10 mlc 24 kw PRE-TREATMENT Raw water tank pumping 2+1 Vertical pump, 360 m 3 /h at 40 mlc 75 kw UV disinfection in cartridge filters 4 UV Rays items to unitary Capacity 360 m 3 /h Cartridge filters 4 Unitary capacity 360 m 3 /h. Material: GRP REVERSE OSMOSIS Nº RO Racks / Composition / Capacity 4 1 pass 2 stages, Recovery Rate 75%, final capacity per train: 135 m 3 /h 1st Stage Set-up 16 Pressure vessels, 6 membranes/vessel, Dow spiral wound 2nd Stage Set-up 8 Pressure vessels, 6 membranes/vessel, Dow spiral wound High-Presssure Pumps 4 Horizontal Pumps, 180 m 3 /h at 130 mlc 110 kw Chemical cleaning system 1 Tank of 8 m 3, (2x100%) horizontal pumps, 144 m 3 /h at 55 mlc 30 kw YEAR OF OPERATION: 2010 POST-TREATMENT Osmotic Balance Tank 1 Tank of 100 m 3, diameter 3.5 m and height 12 m Ethylene tretrachloride removal 2 Stripping towers. Diameter 2.2 m and height 7.5 m. Fan for 4,000 m 3 /h of air per tower. Capacity to be treated per tower: 270 m 3 /h Remineralization 1 Liquid/gas storage tank and CO 2 distribution grids in the product water tank. 1 Lime storage silo of 40 m 3 and dosing system. 1 Lime saturator (Metal clarifier Accentrifloc). Diameter 4.4 m. SUPPLY Product water pumping 3+1 Vertical pump, 180 m 3 /h at 65 mlc 55 kw Desalination Dossier
24 DWTP Sant Joan Despí SPAIN Capacity: 206,064 m 3 /day (54.44 MGD) Type of treatment: UF+RO Year of operation: 2010 cadagua
25 Client: Location: Capacity: Raw Water: Use: Contract type: Sociedad General de Aguas de Barcelona (AGBAR) Barcelona (Spain) 206,064 m 3 /day (54.44 MGD) Brackish water - TDS= 1,100 to 1,300 mg/l Process Description Process Line Main Equipment PRETREATMENT (ULTRAFILTRATION) UF Racks/Configuration/Capacity sets/train and 57 modules of UF membranes/set. 1,193 m 3 /h and train UF Permeate Pumps 9 Horizontal Centrifugal, 1,365 m 3 /h at 13 mlc, 75 kw UF Water Pumps to RO 10+2 Vertical Centrifugal, 954 m 3 /h at 60 mlc, 250 kw CIP System - Dosing System: Caustic Soda, Phosphoric Acid, Sodium Bisulphite, Hypochlorite Cartridge Filters Pre-Desinfection 5 UV units, high density lamps, pressurized, unitary capacity 1,908 m 3 /h Cartridge Filters Pre-Desinfection 5 Unitary capacity 1,908 m 3 /h, PP cartridges, 2.5x50, 5 nominal micron RO Pre-Desinfection 5 UV units, high density lamps, pressurized, 1,908 m 3 /h unitary flow RO Chemical Products System - Dosing: Sulphuric Acid, Sodium Bisulphite, Antiscalant REVERSE OSMOSIS SYSTEM RO racks/composition/capacity 10 1 pass, 3 stages, total conversion 90%, m 3 /h unit 1st Stage Configuration 90 Pressure vessels, 7 membranes/vessel, 630 membranes per train 2nd Stage Configuration 40 Pressure vessels, 7 membranes/vessel, 280 membranes per train 3rd Stage Configuration 28 Pressure vessels, 7 membranes/vessel, 196 membranes per train High Pressure Pumps (1st Stage) 10 Centrifugal Pumps, 954 m 3 /h at 131 mlc, 500kW Inter-Stage Pumps (booster) (3rd Stage) 10 Pump Group-Motor, 230 mv/h at 50 mlc, 55kW Chemical Cleaning System 1 Tank 70 m 3 working capacity, (2+1S) 405 m 3 /h pumps at 60 mlc Shifting System 1 Tank 100 m 3 working capacity YEAR OF OPERATION: 2010 POST- TREATMENT Remineralization System: Calcite Filters and CO 2 Calcite Filters 4 Cells 6x4 m 2, regular bed 2.50 m high, maximum 2.80 m high CO 2 Systems 1 Liquid/Gas Storage Tank and linear injection Desalination Dossier
26 WWTP Campo de Dalías SPAIN Capacity: I MF: 28,600 m3/day (7.54 MGD) II RO: 12,000 m3/day (3.16 MGD) Type of treatment: MF + RO Year of operation: 2008 cadagua
27 Client: Location: Aguas de las Cuencas Mediterráneas, S.A. (ACUAMED) Almería (Spain) (I) MICROFILTRATION Capacity: 28,600 m 3 /day (7.54 MGD) Raw Water: SS Effluent Conductivity= 3,800 µs/cm (II) REVERSE OSMOSIS Capacity: 12,000 m 3 /day (3.16 MGD) Raw Water: Microfiltered water Conductivity= 3,800 µs/cm Use: Contract type: Irrigation Process Line Process Description ADRA EL EJIDO ROQUETAS Main Equipment PRE-TREATMENT Self-backwashing sand filters Microfiltration modules Ferric chloride, sulfuric acid, sodium hypochlorite, sodium, bisulphite and sodium hydroxide dosing systems REVERSE OSMOSIS Feed pumps Cartridge filters RO Racks, 3,500 m 3 /day/unit. PERMETEC YEAR OF OPERATION: 2008 CHEMICAL CLEANING Chemical cleaning equipment Antiscalant and sulfuric acid dosing systems Desalination Dossier
28 SWDP Dhekelia IV CYPRUS Capacity: 60,000 m 3 /day (15.85 MGD) Type of treatment: RO Year of operation: 2008 cadagua
29 Client: Location: Capacity: Raw water: Use: Contract type: Caramondani Desalination Plants Dhekelia (Cyprus) 60,000 m 3 /day (15.85 MGD) Seawater - TDS = 42,000 mg/l EPM Process Description Process Line Main Equipment PRE-TREATMENT Seawater Pumping 4 Centrifugal Pumps Pre-treatment 3 Gravity Dual Media Filters (sand+anthracite) 4 Cartridge Filters Filtered seawater Pumping Centrifugal Pumps (two groups for HPP and ERS) 1 st RO PASS RO Racks 0 6,000 m 3 /day per unit High Pressure Pumping 3 H.P. Centrifugal Pumps Energy Recovery System 9 Booster Pumps YEAR OF OPERATION: nd RO PASS Second Pass Feedwater Pumping 5 Centrifugal Pumps RO Racks 5 4,000 m 3 /day BORON REMOVAL Boron Removal Feedwater Pumping 4 Centrifugal Pumps Treated Water Pumping 4 Centrifugal Pumps IX vessels 9 2,800 mm. diameter Resin Type Rohm & Hass - AMBERLITE IRA 743 Desalination Dossier
30 SWDP Valdelentisco SPAIN Capacity: 200,000 m 3 /day (52.8 MGD) I - 75,000 m 3 /day II - 137,500 m 3 /day Type of treatment: RO Year of operation: I II cadagua
31 Client: Location: Capacity: Raw water: Use: Contract type: Aguas de la Cuenca del Segura, S.A. (ACUASEGURA) Murcia (Spain) 200,000 m 3 /day (52.83 MGD) I: 75,000 m 3 /day II: 137,500 m 3 /day Seawater - TDS=38,500 mg/l I - II - /Irrigation + OM Process Description Process Line I II Main Equipment SEAWATER INTAKE Open Sea Intake Seawater Intake Pipe 1 1 L= 1,474 m, DN-18000, Partial tunnelling + HDPE laid pipe, capacity 16.8 ML/h Seawater Intake Pumping St. 1 1 Pit built in deep tower 5 m diameter x 5 m high, depth 25 m Submersible Centrifugal Pumps, 1,800 m 3 /h at 45 m, 415 kw. Chemical Dosings 4 4 Sulphuric Acid, Ferric Chloride, Sodium Hypochlorite, Polyelectrolyte dosing systems PRETREATMENT Booster Pumping to Filters 6 11 Centrifugal Pump with frequency converter, 1,030 m 3 /h at 60 m, 250 kw. Coarse Filtration Step Dual Media Pressure Filters (sand + anthracite), 3.6 m day x L= 10.5 m Chemical Dosings 3 3 Sodium Hydroxide, Sodium Bisulphite, Antiscalant dosing systems Fine Filtration Cartridge Filters, capacity 1,000 m 3 /h/each REVERSE OSMOSIS High Pressure Pumping 6 11 Pump Groups - Motor - Pelton Turbine, 515 m 3 /h at 640m, 1,600 kw. Interstage Pumping (booster) 6 11 Centrifugal Pump with frequency converter, 660 m 3 /h at 110m, 315 kw. Reverse Osmosis 6 6 Two Stage Racks x 12,500 m 3 /day, conversion rate 50%, DOW. 1 st Stage 85 pressure vessels, 7 elements/vessel, 595 elements/stage, SW30HRLE400i 2 nd Stage 57 pressure vessels, 7 elements/vessel, 399 elements/stage, SW30HRLE400i 5 Two Stage Racks, conversion rate 50%, HYDRANAUTICS. 1 st Stage 78 pressure vessels, 7 elements/vessel, 595 elements/stage, SWC4 MAX. 2 nd Stage 52 pressure vessels, 7 elements/vessel, 399 elements/stage, SWC5 MAX. Chemical Cleaning and Flushing 2 2 Tank for cleaning and neutralization 35 m 3, 2+1S 400 m 3 /h 50m YEAR OF OPERATION: Phase I / Phase II POST- TREATMENT 1 1 Calcium Hydroxide Storage and Dosing and CO 2 for LSI and SA adjustment. EFFLUENT TREATMENT 1 1 Thickening & Dewatering of sludge from backwash effluent. ph adjustment of wasted cleaning chemical solution. SEAWATER OUTFALL 1 1 1,259 m, DN-1600, HPPE pipe Desalination Dossier
32 SWDP Dhekelia III CYPRUS Capacity: 40,000 m 3 /day (10.57 MGD) Type of treatment: RO Year of operation: 2007 cadagua
33 Client: Location: Capacity: Raw water: Use: Contract type: Caramondani Desalination Plants Dhekelia (Cyprus) 40,000 m 3 /day (10.57 MGD) Seawater - TDS = 42,000 mg/l EPM Process Description Process Line Main Equipment SEAWATER INTAKE Seawater pumping 4 Centrifugal pumps PRE-TREATMENT 3 Gravity Dual Media Filters (sand + anthracite) 4 Cartridge Filters Filtered seawater pumping 3+3 Centrifugal pumps (two groups for HPP and ERS) FIRST RO PASS YEAR OF OPERATION: 2007 High pressure pumping 3 HP Centrifugal pumps Energy Recovery System 9 Booster Pumps Second pass feedwater pumping 4+4 Centrifugal pumps (two groups in series) Boron removal feedwater pumping 4 Centrifugal pumps Treated water pumping 4 Centrifugal pumps Desalination Dossier
34 SWDP Melilla SPAIN Capacity: 20,000 m 3 /day (5.28 MGD) Type of treatment: RO Year of operation: 2007 cadagua
35 Client: Location: Capacity: Raw water: Use: Contract type: Ministerio de Medio Ambiente (MMA) Melilla (Spain) 20,000 m 3 /day (5.28 MGD) Seawater - TDS=38,500 mg/l DBOO (O&M 12 years) Process Description Process Line Main Equipment SEAWATER PUMPING 3+1 Submersible centrifugal pumps PRE-TREATMENT 3 Sodium hypochlorite, coagulant and polyelectrolyte dosing systems. 6 Pressure dual media filters (sand + anthracite) - 1 st stage Filtered water pumping 3+1 Centrifugal pumps 4 Pressure dual media filters (sand + anthracite) - 2 nd stage Filters backwashing system 2+1 Backwashing water pumps 1+1 Air scouring blowers 3 Sulfuric acid, antiscalant, sodium bisulphite dosing systems. 4 Cartridge filters YEAR OF OPERATION: 2007 REVERSE OSMOSIS High-Pressure pumping 3+1 Pump - Motor -Turbine Groups Reverse Osmosis 3 RO Racks; Recovery: 45%. Filmtec SW30HR LE-400 Shifting System/Chemical cleaning 2+1 Centrifugal pumps POST-TREATMENT 2 Lime and CO 2 remineralization systems 1 Sodium hypochlorite dosing system Treated water pumping 2+1 Centrifugal pumps Desalination Dossier
36 WWTP Rincón de León SPAIN Capacity: 50,000 m 3 /day (UF) (13.21 MGD) 25,000 m 3 /day (RO) (6.60 MGD) Type of treatment: UF + RO Year of operation: 2006 cadagua
37 Client: Location: Entidad Pública de Saneamiento de Aguas Residuales de la Comunidad Valenciana (EPSAR) Alicante (Spain) (I) ULTRAFILTRATION Capacity: 50,000 m 3 /day (13.21 MGD) Raw Water: SS Effluent Conductivity= 2,800 S/cm (III) REVERSE OSMOSIS Capacity: 25,000 m 3 /day (6.60 MGD) Raw Water: Ultrafiltrated water Conductivity= 2,800 µs/cm Use: Contract type: Irrigation. + O&M Process Description Process Line ULTRAFILTRATION Main Equipment 2 Lines of mixing and flocculation chambers 2 Lamellar settling tanks 3 Protection filters 6 Ultrafiltration modules 6 Ferric chloride, polyelectrolyte, nitric acid, sodium hypochlorite, sodium bisulphite and sodium hydroxide dosing systems. REVERSE OSMOSIS 5 Feed pumps 5 Cartridge filters 4 RO Racks - TRISEP 3 Blending pumps 2 Antiscalant and sulfuric acid dosing systems YEAR OF OPERATION: 2006 CHEMICAL CLEANING 1 Chemical cleaning equipment NEUTRALIZATION 1 Neutralization system Desalination Dossier
38 SWDP Madinat Yanbu Al-Sinaiyah SAUDI ARABIA Capacity: 50,400 m 3 /day (13.32 MGD) Type of treatment: RO Year of operation: 2006 cadagua
39 Client: Location: Capacity: Raw water: Use: Contract type: Royal Commission for Jubail and Yanbu Yanbu (Saudi Arabia) 50,400 m 3 /day (13.32 MGD) Seawater - TDS = 42,000 mg/l EPM Process Description Process Line Main Equipment PRE-TREATMENT 14 Gravity dual media filters (sand + anthracite) 5 Ferric chloride, polyelectrolyte, sulfuric acid, sodium bisulphite and antiscalant dosing systems 8 Cartridge filters REVERSE OSMOSIS High-Pressure Pumping 6 Pump-Motor-Turbine Groups Reverse Osmosis 6 RO Racks x 8,400 m 3 /day, Toyobo Membranes Recovery Rate: 38.5% POST-TREATMENT Chemical Cleaning 1 Chemical cleaning equipment Post-Treatment 3 Chlorine, lime and caustic soda dosing systems Testing Unit 1 RO Membrane Test Unit YEAR OF OPERATION: 2006 Desalination Dossier
40 SWDP Alicante I - II SPAIN Capacity: 65,000 m3/day (17.17 MGD) Type of treatment: RO Year of operation: I / II cadagua
41 Client: Location: Capacity: Raw water: Use: Contract type: Ministerio de Medio Ambiente (MMA) Alicante (Spain) 65,000 m 3 /day (17.17 MGD) Seawater -TDS = 42,500 mg/l DBOO (O&M 15 years) Process Description Process Line I-II Main Equipment SEAWATER PUMPING Well pumps PRE-TREATMENT 10 Sand filters 5 Sodium hypochlorite, ferric chloride, sulfuric acid, sodium bisulphite and antiscalant dosing systems Cartridge filters HIGH-PRESSURE PUMPING Pump-Motor-Pelton Wheel Turbine Groups REVERSE OSMOSIS 7 RO Racks x 7,200 m 3 /d, RO membranes Toray SU-820 FA 2 RO Racks, RO membranes Toray TM CHEMICAL CLEANING 1 Chemical cleaning equipment Design Pressure: 69 bar (1,000 psi); Recovery Rate > 42-43% YEAR OF OPERATION: Phase I / Phase II POST-TREATMENT 2 Sodium hypochlorite and lime dosing systems Desalination Dossier
42 SWDP Ceuta I - II SPAIN Capacity: 23,286 m 3 /day (6.15 MGD) Type of treatment: RO Year of operation: I / II cadagua
43 Client: Location: Capacity: Raw water: Use: Contract type: I - Ministerio de Obras Públicas, Transporte y Medio Ambiente (MOPTMA) II - Aguas de Ceuta Empresa Municipal, S.A. (ACEMSA) Ceuta (Spain) 23,286 m 3 /day (6.15 MGD) Seawater - TDS = 38,000 mg/l I - + O&M II - DBOO (O&M 30 years) Process Description Process Line I-II Main Equipment SEAWATER PUMPING 5 Centrifugal pumps PRE-TREATMENT 4+3 Pressure sand filters 2 Filter backwashing brine pumps 3 Sodium hypochlorite, sodium bisulphite and antiscalant dosing systems 4+2 Cartridge filters HIGH-PRESSURE PUMPING 4+1 Pump-Motor-Turbine Groups 1 Inter-stage Booster pumping group REVERSE OSMOSIS 3 RO Racks x 5,333 m 3 /day, FILMTEC SWHR-380; Recovery rate: 40-42% 1 RRO Racks x 7,286 m 3 /day, FILMTEC SWHR-380; Recovery rate: 55% 1 Brine concentrator YEAR OF OPERATION: Phase I / Phase II CHEMICAL CLEANING 1 Chemical cleaning equipment POST-TREATMENT 2 Sodium hypochlorite and lime dosing systems PRODUCT WATER PUMPING 4+1 Centrifugal pumps Desalination Dossier
44 SWDP Formentera I - II SPAIN Capacity: 4,000 m 3 /day (1.06 MGD) Type of treatment: RO Year of operation: I / II cadagua
45 Client: Location: Capacity: Raw water: Use: Contract type: I - Ministerio de Medio Ambiente (MMA) II - Ministerio de Fomento Formentera (Spain) 4,000 m3/day (1.06 MGD) Seawater -TDS=42,000 mg/l + O&M Process Description Process Line I-II Main Equipment SEAWATER PUMPING 4+2 Multistage submersible pumps PRE-TREATMENT 3+2 Pressure sand filters 3 Sodium hypochlorite, sodium bisulphite and antiscalant dosing systems 3+1 Cartridge filters HIGH-PRESSURE PUMPING 3+2 Pump-Motor-Turbine Groups REVERSE OSMOSIS 2 RO Racks x 1,000 m 3 /day, Dupont B10T-6845 Design Pressure: 83.7 bar (1,200 psi); Recovery Rate: 40% 1 RO Racks x 2,000 m 3 /day, Toray SU-820 FA Design Pressure: 70 bar (1,000 psi); Recovery Rate: 45% PRODUCT STORAGE TANK m 3 painted carbon steel tank 1 17,500 m 3 concrete tank YEAR OF OPERATION: Phase I / Phase II CHEMICAL CLEANING 1 Chemical cleaning equipment POST-TREATMENT 1 Remineralisation system by calcium carbonate and CO 2 1 Sodium hypochlorite dosing system Desalination Dossier
46 BWDP Zarzis I - II TUNISIA Capacity: 15,000 m 3 /day (3.96 MGD) Type of treatment: RO Year of operation: I / II cadagua
47 Client: Location: Capacity: Raw water: Use: Contract type: La Société Nationale d Exploitation et de Distribution des Eaux (S.O.N.E.D.E.) Zarzis (Tunisia) 15,000 m 3 /day (3.96 MGD) Brackish water - TDS = 6,000-8,000 mg/l I - + O&M / II - Process Description Process Line I-II Main Equipment PRE-TREATMENT 1 Oxidation / aeration pond 2 Sludge blanket recirculation settlers 4 Gravity dual media filters (sand + anthracite) 4 Sodium hypochlorite, coagulant, soda and lime dosing systems 3 Filtered water pumps 3 Cartridge filters REVERSE OSMOSIS 3 High-Pressure Pumps POST-TREATMENT 3 Degassers 3 Sulfuric acid, antiscalant and sodium bisulphite dosing systems. 3 RO Racks x 5,000 m 3 /d. Hydranautics CPA3 Design Pressure: 14 bar; Recovery Rate. 75% 1 Caustic soda dosing system. YEAR OF OPERATION: Phase I / Phase II Desalination Dossier
48 BWDP Jerba I - II TUNISIA Capacity: 15,000 m 3 /day (3.96 MGD) Type of treatment: RO Year of operation: I / II cadagua
49 Client: Location: Capacity: Raw water: Use: Contract type: La Société Nationale d Exploitation et de Distribution des Eaux (S.O.N.E.D.E.) Jerba (Tunisia) 15,000 m 3 /day (3.96 MGD) Brackish water - TDS = 5,500-7,000 mg/l I - + O&M / II - Process Description Process Line I-II Main Equipment PRE-TREATMENT 1 Oxidation / aeration pond 2 Sludge blanket recirculation settlers 4 Gravity dual media filters (sand + anthracite) 4 Sodium hypochlorite, coagulant, soda and lime dosing systems 3 Filtered water pumps 3 Cartridge filters REVERSE OSMOSIS 3 High-Pressure Pumps POST-TREATMENT 3+1 Degassers 3 Sulfuric acid, antiscalant and sodium bisulphite dosing systems. 3 RO Racks x 5,000 m 3 /day, Hydranautics CPA3 Design Pressure: 14 bar; Recovery Rate. 75% 1 Caustic soda dosing system. YEAR OF OPERATION: I / II Desalination Dossier
50 SWDP San Nicolás de Tolentino SPAIN Capacity: 5,000 m 3 /day (1.32 MGD) Type of treatment: RO Year of operation: 2001 cadagua
51 Client: Location: Capacity: Raw water: Use: Contract type: Consejo Insular de Aguas de Gran Canaria Canary Islands (Spain) 5,000 m3/day (1.32 MGD) Seawater -TDS=38,000 mg/l + O&M Process Description Process Line Main Equipment SEAWATER PUMPING 3 Centrifugal pumps PRE-TREATMENT 2 Pressure sand filters 4 Sodium hypochlorite, sulfuric acid, sodium bisulphite and antiscalant dosing systems 2 Cartridge filters HIGH-PRESSURE PUMPING 1 Pump-Motor-Turbine Group REVERSE OSMOSIS 1 RO Racks x 5,000 m 3 /d, Hydranautics SWC-3; Recovery Rate: 45% YEAR OF OPERATION: 2001 CHEMICAL CLEANING 1 Chemical cleaning equipment POST-TREATMENT 1 Lime dosing system Desalination Dossier
52 SWDP Sta. Cruz de Tenerife SPAIN Capacity: 20,700 m 3 /day (5.46 MGD) Type of treatment: RO Year of operation: 2001 cadagua
53 Client: Location: Capacity: Raw water: Use: Contract type: Ministerio de Medio Ambiente (MMA) Santa Cruz de Tenerife (Spain) 20,700 m 3 /day (5.46 MGD) Seawater - TDS = 39,000 mg/l + O&M Process Description Process Line Main Equipment SEAWATER PUMPING 8 Centrifugal pumps PRE-TREATMENT 8 Pressure sand filters - 1 st Filtration Stage 4 Pressure dual media filters (sand+anthracite) - 2 nd Filtration Stage 6 Sodium hypochlorite, ferric chloride, sulfuric acid, sodium bisulphite, coagulant and antiscalant dosing systems 6 Cartridge filters HIGH-PRESSURE PUMPING 4 Pump-Motor-Turbine Groups (1 st pass) YEAR OF OPERATION: 2001 LOW-PRESSURE PUMPING 3 Motor-Pump Groups (2 nd pass) REVERSE OSMOSIS 3 RO Racks. Hydranautics SWC-3. Design Pressure: 69 bar (1,000 psi); Recovery Rate: 42%, 6,900 m 3 /day 3 RO Racks. Hydranautics ESPA2. Design Pressure: 12 bar (174 psi); Recovery Rate: 85%, 4,284 m 3 /day CHEMICAL CLEANING 1 Chemical cleaning equipment POST-TREATMENT 3 Sodium hypochlorite, lime and CO 2 dosing systems. Desalination Dossier
54 SWDP Dhekelia I - II CYPRUS Capacity: 40,000 m 3 /day (10.57 MGD) Type of treatment: RO Year of operation: I / II cadagua
55 Client: Location: Capacity: Raw water: Use: Contract type: Caramondani Desalination Plants Dhekelia (Cyprus) 40,000 m 3 /day (10.57 MGD) Seawater - TDS = 42,000 mg/l EPM Process Description Process Line I-II Main Equipment OPEN SEA INTAKE SEAWATER PUMPING 3+2 Centrifugal pumps PRE-TREATMENT 6+5 Gravity dual (sand+anthracitte) media filters 6 Coagulant, polyelectrolyte, sodium hypochlorite, sulfuric acid, sodium bisulphite and antiscalant dosing systems 7+6 Cartridge filters HIGH PRESSURE PUMPING 5+4 Pump-Motor-Turbine Groups YEAR OF OPERATION: I / II REVERSE OSMOSIS 4+4 RO Racks x 5,000 m3/d - Dupont B10T-6880 TWIN Design Pressure: 82.7 bar (1,200 psi) Recovery Rate: 50% CHEMICAL CLEANING 1 Chemical cleaning equipment POST-TREATMENT 3 Sodium hypochlorite, CO 2 and lime dosing systems Desalination Dossier
56 SWDP Agragua I - II SPAIN Capacity: 15,000 m3/day (3.96 MGD) Type of treatment: RO Year of operation: I / II cadagua
57 Client: Location: Capacity: Raw water: Use: Contract type: Agragua, S.A. Gran Canaria (Spain) 15,000 m 3 /day (3.96 MGD) Seawater -TDS=38,000 mg/l Irrigation I - II - DBOO (O&M 22 years) Process Description Process Line I-II Main Equipment SEAWATER PUMPING 3 Centrifugal pumps PRE-TREATMENT 3 Pressure sand filters 5 Coagulant, sodium hypochlorite, sulfuric acid, sodium bisulphite and antiscalant dosing systems 3 Cartridge filters HIGH PRESSURE PUMPING 3 Pump-Motor-Turbine Groups REVERSE OSMOSIS 2 RO Racks x 5,000 m 3 /d - Dupont B10T RO Racks x 5,000 m3/day Filmtec SW30HR-380 Design Pressure: 69 bar (1,000 psi); Recovery Rate: 45% YEAR OF OPERATION: I / II CHEMICAL CLEANING 1 Chemical cleaning equipment POST-TREATMENT 2 Sodium hypochlorite and lime dosing systems Desalination Dossier
58 SWDP Ibiza SPAIN Capacity: 9,000 m3/day (2.38 MGD) Type of treatment: RO Year of operation: 1996 cadagua
59 Client: Location: Capacity: Raw water: Use: Contract type: Gobierno de las Islas Baleares Ibiza (Spain) 9,000 m 3 /day (2.38 MGD) Seawater - TDS=38,000 mg/l O&M Process Description Process Line Main Equipment SEAWATER PUMPING 6 Centrifugal pumps PRE-TREATMENT 4 Sodium hypochlorite, polyelectrolyte, sulfuric acid and sodium bisulphite dosing systems 8 Pressure sand filters 4 Cartridge filters HIGH-PRESSURE PUMPING 3 Pump - Motor -Turbine Groups REVERSE OSMOSIS 3 RO Racks x 3,000 m3/day - Toray SU 820 Design pressure: 68 bar. Recovery Rate: 40% YEAR OF OPERATION: 1996 CHEMICAL CLEANING 1 Chemical cleaning equipment. POST-TREATMENT 2 Lime and sodium hypochlorite dosing systems. Desalination Dossier
60 BWDP Bajo Almanzora SPAIN Capacity: 30,000 m 3 /day (7.93 MGD) Type of treatment: Nanofiltration Year of operation: 1996 cadagua
61 Client: Location: Capacity: Raw water: Use: Contract type: Junta de Andalucía Almería (Spain) 30,000 m 3 /day (7.93 MGD) Brackish water - TDS=1,776 mg/l. + O&M Process Description Process Line Main Equipment PRE-TREATMENT 3 Sulfuric acid, antiscalant and sodium bisulphite dosing systems. 4 Cartridge filters HIGH-PRESSURE PUMPING 4 Centrifugal pumps NANOFILTRATION 3 Racks x 10,000 m3/d - Filmtec NF Design pressure: 10.3 bar (150 psi) ; Recovery Rate: 78% CHEMICAL CLEANING 1 Chemical cleaning equipment YEAR OF OPERATION: 1996 Desalination Dossier
62 SWDP Galdar - Agaete SPAIN Capacity: 3,500 m3/day (0.92 MGD) Type of treatment: RO Year of operation: 1989 cadagua
63 Client: Location: Capacity: Raw water: Use: Contract type: Ayuntamientos de Galdar y Agaete Gran Canaria (Spain) 3,500 m 3 /day (0.92 MGD) Seawater - TDS=38,000 mg/l DBOO (O&M 8 years) Process Description Process Line Main Equipment SEAWATER PUMPING 3 Centrifugal pumps PRE-TREATMENT 4 Pressure sand filters 5 Coagulant, sodium hypochlorite, sulfuric acid, sodium bisulphite and antiscalant dosing systems 3 Cartridge filters HIGH-PRESSURE PUMPING 3 Pump-Motor-Turbine Groups REVERSE OSMOSIS 2 RO Racks x 1,750 m 3 /d - Dupont B10T-6845 Design Pressure: 69 bar (1,000 psi) Recovery Rate: 45% YEAR OF OPERATION: 1989 CHEMICAL CLEANING 1 Chemical cleaning equipment POST-TREATMENT 2 Sodium hypochlorite and lime dosing systems. Desalination Dossier
64 SWDP Lanzarote II SPAIN Capacity: 7,500 m3/day (1.98 MGD) Type of treatment: RO Year of operation: 1986 cadagua
65 Client: Location: Capacity: Raw water: Use: Contract type: Ministerio de Obras Públicas y Urbanismo (MOPU) Lanzarote (Spain) 7,500 m 3 /day (1.98 MGD) Seawater TDS=37,000 mg/l Process Description Process Line Main Equipment SEAWATER PUMPING 5 Centrifugal pumps PRE-TREATMENT 4 Pressure sand filters 3 Coagulant, sulfuric acid and antiscalant dosing systems 4 Cartridge filter HIGH-PRESSURE PUMPING 4 Pump-Motor-Turbine Groups REVERSE OSMOSIS 3 RO Racks x 2,500 m3/d - Dupont B10T-6840 Design Pressure: 82.7 bar (1,200 psi) Recovery Rate: 45% YEAR OF OPERATION: 1986 CHEMICAL CLEANING 1 Chemical cleaning equipment POST-TREATMENT 2 Sodium hypochlorite and sodium carbonate dosing system Desalination Dossier
66
67 Water for human progress
68 Offices in Spain BILBAO (HEAD OFFICE) Gran Vía, 45 7th & 8th Bilbao - SPAIN Phone: Fax: [email protected] MADRID (GENERAL MANAGEMENT) Ribera del Loira, 42 - Parque Empresarial Puerta de las Naciones Madrid - SPAIN Phone: Fax: [email protected] International offices POLAND Cadagua SA Oddział w Polsce - ul. Dzielna, Warszawa - POLAND Phone: Fax: [email protected] PORTUGAL Rua Adelino Amaro da Costa, 9º C/V Esq Amadora - PORTUGAL Phone: Fax: UNITED ARAB EMIRATES Suite No. 103E Ibn Battuta Gate Office (next to Ibn Battuta Mall) Jebel Ali P.O. Box Dubai - UAE Phone: Fax: [email protected] OMAN P.B. No: 1884, Jibroo - Al Nadha Press Building Al Wattayah Street - OMAN Phone: / Fax: [email protected] KINGDOM OF SAUDI ARABIA B.O. Bldg. 4th Floor, P.O. Box 2923 Al Sahafa District, Riyadh KSA Phone: (+966) /27 /28 - Fax: (+966) MOROCCO Boulevard d Anfá 140, 1st, apart Nº Casablanca - MOROCCO Phone: +212 (0) Fax: +212 (0) [email protected] UNITED STATES OF AMERICA 9600 Great Hills Trail, Suite 200 E, Austin TX (USA) Phone: /88 - Fax: [email protected] PERU Coronel Andres Reyes Edificio Onyx - Oficina San Isidro Lima (Perú) Phone: Fax: CHILE Avda. Andrés Bello, 2711, Piso 18, Las Condes - Santiago (Chile) Phone: /80/81 - Fax:
References of Reverse Osmosis Plants
References of Reverse Osmosis Plants Al Ghubrah (Omán) Oman Power and Water Procurement Company DAF RO El Morro (Chile) GoldCorp (Chile) UF + RO Jorf Lasfar (Morocco) Office Chérifien des Phosphates (Morocco)
7 Years Operation of BWRO Plant with Raw Water from Coastal Aquifer for Agriculture Irrigation
7 Years Operation of BWRO Plant with Raw Water from Coastal Aquifer for Agriculture Irrigation Authors: Carlos García, Francisco Molina and Domingo Zarzo Valoriza Agua, C/Molina de Segura, nº8, 30004,
DOW Ultrafiltration. Case History. High Turbidity and Temperature Fluctuation No Obstacle for DOW Ultrafiltration
Case History High Turbidity and Temperature Fluctuation No Obstacle for Site Information Location: HeBei, China Capacity: 12 m 3 /h (5283 gpm) Purpose: Pretreat sea water prior to RO system Time in Operation:
The Grand Miramare Hotel Santa Margherita (Portofino) Italy March 19 22, 2013. Inspiring Innovation and Excellence
The Grand Miramare Hotel Santa Margherita (Portofino) Italy March 19 22, 2013 Inspiring Innovation and Excellence About the IDA Desalination Academy The IDA Desalination Academy aspires to increase knowledge
Membrane Filtration Technology: Meeting Today s Water Treatment Challenges
Membrane Filtration Technology: Meeting Today s Water Treatment Challenges Growing global demand for clean water and increasing environmental concerns make membrane filtration the technology of choice
Highly Colored Water Removal Using Nanofiltration Membranes at the Colored Water Treatment Facility. Adam Zacheis, Project Manager Carollo Engineers
Highly Colored Water Removal Using Nanofiltration Membranes at the Colored Water Treatment Facility Adam Zacheis, Project Manager Carollo Engineers Topics 1. Background - Mesa Water District (Mesa) Water
INTERSTAGE ENERGY RECOVERY TURBINE APPLICATION MARCO ISLAND, FLORIDA
IWC-00-15 INTERSTAGE ENERGY RECOVERY TURBINE APPLICATION MARCO ISLAND, FLORIDA JULIA NEMETH, PE Harn R/O Systems, Incorporated Venice, Florida STEVEN DURANCEAU, PHD, PE Boyle Engineering Corporation Orlando,
Indiana s Newest Filtration Facility; East Chicago
Indiana s Newest Filtration Facility; East Chicago Innovation and Value-Added Benefits Behind East Chicago s Membrane Treatment Facility Eric Horvath, PE and Kara M. Boyles, PhD, PE August 1, 2012 Presentation
Pall Aria Integrated MF/RO Systems for Cost-Effective Treatment of Sea and Brackish Waters
Pall Aria Integrated MF/RO Systems for Cost-Effective Treatment of Sea and Brackish Waters Pall Aria Integrated MF/RO Systems for Cost-Effective Treatment of Sea and Brackish Waters Water scarcity resulting
Applying Life Cycle Assessment to Drinking Water Treatment
Applying Life Cycle Assessment to Drinking Water Treatment W.Takashima*, S.Takizawa**and M. Fujiwara* *Japan Water Research Center, Minato-ku, Tokyo, 105-0001, Japan ([email protected]) ** University
FILMTEC Membranes Strategies for Using FILMTEC Elements to Lower Your Total Cost of Seawater Desalination
Tech Fact FILMTEC Membranes Strategies for Using FILMTEC Elements to Lower Your Total Cost of Seawater Desalination As demand for drinking water continues to increase particularly in regions of the world
MARBELLA SEAWATER DESALINATION PLANT: CONSTRUCTION AND START - UP EXPERIENCE. Juan María Sánchez, Juan Velasco, Jose M. Kindelan and Jaime Andreu
MARBELLA SEAWATER DESALINATION PLANT: CONSTRUCTION AND START - UP EXPERIENCE AUTHORS: Juan María Sánchez, Juan Velasco, Jose M. Kindelan and Jaime Andreu ABSTRACT: Marbella seawater desalination Plant
Water Treatment and Reverse Osmosis Systems
Water 2012 Treatment Pure Aqua, and Inc. Reverse All Rights Osmosis Reserved. ystems Worldwide Experience uperior Technology About the Company Pure Aqua is a company with a strong philosophy and drive
ECOAZUR BLUEWATER WATER PURIFICATION PLANTS
ECOAZUR BLUEWATER WATER PURIFICATION PLANTS CONTACT EcoAzur Calle 11a #492 x 60 y 62 Tel: +52-999-920-1972 Col. Residencial Pensiones Email: [email protected] C.P. 97217 Merida, Yucatan, Mexico Website:
HUBER Vacuum Rotation Membrane VRM Bioreactor
HUBER Vacuum Rotation Membrane VRM Bioreactor VRM The rotating plate membrane for clean water applications. The future-oriented solution designed for the ever increasing requirements in wastewater treatment
How To Water System
Mid-Monroe Water System: Soluble Iron and Manganese Removal via Oxidation & Filtration Daniel Rickard, P.E. Engineering Project Manager Pennsylvania-American Water Company Who Is American Water We are
RO Reverse Osmosis equipments
RO SYSTEMS RO Reverse Osmosis equipments A range of Reverse Osmosis equipment designed to provide the highest performances with flow rates demand from 50 to 1000 l/h. Every component of the equipment is
EASTERN IRRIGATION SCHEME, VICTORIA: OPERATION OF AN ULTRA-FILTRATION PLANT FOR A CLASS A RECYCLED WATER SCHEME. David Aitken. Earth Tech Engineering
EASTERN IRRIGATION SCHEME, VICTORIA: OPERATION OF AN ULTRA-FILTRATION PLANT FOR A CLASS A RECYCLED WATER SCHEME Paper Presented by : David Aitken Authors: David Aitken, Plant Operator, Liz Roder, Operations
MEMBRANE TECHNOLOGY TREATING OILY WASTEWATER FOR REUSE
MEMBRANE TECHNOLOGY TREATING OILY WASTEWATER FOR REUSE Jeff Peeters, P.Eng. ZENON Environmental Inc. SAWEA 2005 Workshop Al-Khobar Holiday Inn Hotel, Saudi Arabia November 29, 2005 Presentation outline
Municipal Standard Solutions. Water Treatment WATER TECHNOLOGIES
Municipal Standard Solutions Water Treatment WATER TECHNOLOGIES Standard Units and Tailor-made Systems Veolia provides the complete range of services required to design, build, maintain and upgrade water
The most complete solutions in GRP PIPES AND FITTINGS. ABRERA WATER TREATMENT PLANT (Barcelona) PROJECT REPORT DWTP 2010 / D - 7
The most complete solutions in GRP PIPES AND FITTINGS 1 ABRERA WATER TREATMENT PLANT (Barcelona) 2010 / D - 7 PROJECT REPORT DWTP ABRERA DRINKING WATER TREATMENT PLANT Project Managers Plant Owner: Aigües
ITT Water Equipment Technologies. ITT Flowtronex. Water Equipment Technologies & Flowtronex
ITT Water Equipment Technologies ITT Flowtronex Water Equipment Technologies & Flowtronex 1975 Water Equipment Technologies (WET) is created to provide advanced filtration technologies. 1988 WET, in conjunction
IMPACT OF CHEMICALS ADDITION IN WATER/WASTEWATER TREATMENT ON TDS CONCENTRATION AND SLUDGE GENERATION Jurek Patoczka, PhD, PE Hatch Mott MacDonald 27 Bleeker Str., Millburn, NJ 07041 (973) 912 2541 [email protected]
7. TECHNICAL ASPECTS OF DESALINATION PLANT
7. TECHNICAL ASPECTS OF DESALINATION PLANT 7.1 DESALINATION TECHNOLOGIES Desalination technologies can be classified according to the process involved, for example: Those involving phase change in water,
4 th & Carey Groundwater. Remediation Project and Reverse Osmosis Water Treatment System
4 th & Carey Groundwater Remediation Project and Reverse Osmosis Water Treatment System Contaminated City Well Well #8 4 th and Carey Groundwater contamination from industry was discovered in the Southeast
Facility Classification Standards
Facility Classification Standards Approval Date: April 3, 2009 Effective Date: April 3, 2009 Approved By: Nancy Vanstone, Deputy Minister Version Control: Replaces Facility Classification Standards dated
Cambria Emergency Water Supply
Cambria Community Services District Cambria Emergency Water Supply Title 22 Engineering Report July 2014 This document titled "Cambria Emergency Water Supply Title 22 Engineering Report", dated June 2014,
Life Cycle Assessment of Three Water Scenarios: Importation, Reclamation, and Desalination
Life Cycle Assessment of Three Water Scenarios: Importation, Reclamation, and Desalination Erin Lyons, Peng Zhang, Troy Benn, Miles Costanza, Ke Li, John Crittenden Department of Civil and Environmental
ABENGOA WATER. Annual Report 2012. Table of Contents
Table of Contents Table of Contents Chairman s Report 5 Abengoa Water s Profile 9 Mission, vision, and values Organizational structure International presence Financial Data 15 Activities 19 Activities
ASSESSMENT OF WASTEWATER TREATMENT AND WATER REUSE PRACTICES IN THE GULF COUNTRIES
ASSESSMENT OF WASTEWATER TREATMENT AND WATER REUSE PRACTICES IN THE GULF COUNTRIES Mohamed F. Hamoda Professor of Water Resources and Environmental Engineering Department of Civil Engineering, Kuwait University
Chemistry at Work. How Chemistry is used in the Water Service
Chemistry at Work How Chemistry is used in the Water Service WATER TREATMENT Everyday, more than 100 water treatment works in Northern Ireland put approximately 680 million litres of water into the supply
TREATMENT OF PHOSPHATE FERTILIZER PLANT WASTE WATER IN FLORIDA FOR DISCHARGE AND RE USE PURPOSES
TREATMENT OF PHOSPHATE FERTILIZER PLANT WASTE WATER IN FLORIDA FOR DISCHARGE AND RE USE PURPOSES JOHN F. BOSSLER, SIEMENS Water Technologies Corp., Hoffman Estates, IL RONALD TRAVIS, SIEMENS Water Technologies
PERFECT TECHNOLOGY MAKES THE DIFFERENCE JUDO REFERENCES
PERFECT TECHNOLOGY MAKES THE DIFFERENCE JUDO REFERENCES JUDO Filtration systems More than Up-to-date Filter technique Filter Types JEF-F for decolouring JEF-E for deferrization JEF-M for demanganization
Removing Heavy Metals from Wastewater
Removing Heavy Metals from Wastewater Engineering Research Center Report David M. Ayres Allen P. Davis Paul M. Gietka August 1994 1 2 Removing Heavy Metals From Wastewater Introduction This manual provides
Use of Color Removal Membranes on Waste Water Treatment in the Pulp and Paper Industry
Use of Color Removal Membranes on Waste Water Treatment in the Pulp and Paper Industry R.BODA*, W.T.BATES**, C.R.BARTELS, PhD*** * HYDRANAUTICS A NITTO DENKO COMPANY, 11 Laurel Court, Glasgow G72 7BD,
Wastewater Reuse. Typical treated wastewater is:
Wastewater Reuse Most metal finishing industries have in-house wastewater treatment to economically dispose of the acids, alkali, oils, and dissolved metals in the rinse water and occasional tank solution
Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media
Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media ASME Research Committee Power Plant and Environmental Chemistry Overland Park, Kansas April 2-4, 2007 Prepared by: W. H. Stroman Primary
EMERGENCY VAPOR SCRUBBER SYSTEMS
EMERGENCY VAPOR SCRUBBER SYSTEMS Toxic gases such as chlorine, sulfur dioxide and ammonia are commonly used for water and wastewater treatment, and in many industrial fabrication processes. The Uniform
Basics of Reverse Osmosis
What is Reverse Osmosis? Reverse Osmosis is a technology that is used to remove a large majority of contaminants from water by pushing the water under pressure through a semi- permeable membrane. This
Amiad s AMF² pre-treatment technology ensures efficient and reliable nanofiltration of Scottish Highland loch water
technical article Document Ref: 0411001-NFPT-text-RevG Status: Re-issued to Elsevier Science Company: Amiad Filtration Systems Limited Issue Date: 10 February 2006 Copy Deadline: 10 February 2006 Publication:
Winnipeg Sewage Treatment Program Integrated Management System
Winnipeg Sewage Treatment Program Integrated Management System SEWPCC Facility s. DOCUMENT NUMBER: CD-RC-RF-02 Rev Prepared by Reviewed by Date Approved by Date 2014/04/02 Philippe Biesse Bruno Valla 2014/04/02
CWD BALDWIN PLANT NEW RESIDUALS HANDLING SYSTEM
CWD BALDWIN PLANT NEW RESIDUALS HANDLING SYSTEM OTCO Water Workshop March, 2011 Frank Woyma Plant Manager Nick Pizzi Vice-President EE&T ENVIRONMENTAL ENGINEERING & TECHNOLOGY, INC. Objectives Review the
Technology Selection Tools for Boiler Feedwater Applications (US Units)
Technical Paper Technology Selection Tools for Boiler Feedwater Applications (US Units) Authors: Robert Gerard and Roch Laflamme, GE Water & Process Technologies Introduction During the last decade, the
GUIDELINES FOR LEACHATE CONTROL
GUIDELINES FOR LEACHATE CONTROL The term leachate refers to liquids that migrate from the waste carrying dissolved or suspended contaminants. Leachate results from precipitation entering the landfill and
Wastewater Nutrient Removal
Wastewater Nutrient Removal An overview of phosphorus and nitrogen removal strategies Presented by: William E. Brown, P.E. Peter C. Atherton, P.E. Why are nutrients an issue in the environment? Stimulates
Tampa Bay Seawater Desalination Plant
Tampa Bay Seawater Desalination Plant Project History How The Plant Works Desal Fun Facts 2575 Enterprise Road, Clearwater, FL 33763-1102 Phone: 727.796.2355 / Fax: 727.791.2388 www.tampabaywater.org Tampa
Saudi Aramco Project Development
Saudi Aramco Project Development Wastewater Treatment Facilities Jeddah Refinery And Marine Area December 2007 Facilities Planning Dept. OBJECTIVE: Provide an overview of the complexities of developing
More inside :: Tackle even the toughest water treatment piping challenges with
More inside :: Tackle even the toughest water treatment piping challenges with Corzan Industrial Systems Corrosion to pipes, valves and fittings caused by chemicals and microbes can greatly impact the
SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS
SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS Published in Water and Waste Digest membrane issue, November 2008 Miroslav Colic; Chief Scientist, Clean Water Technology
Cambridge Wastewater Treatment Facility
Cambridge Wastewater Treatment Facility Emergency Situations If you have a water or sewer emergency that relates to the City s utility system call the Public Works office at 763-689-1800 on normal working
Economic Siting Factors for Seawater Desalination Projects along the Texas Gulf-Coast
Economic Siting Factors for Seawater Desalination Projects along the Texas Gulf-Coast Mark Graves and Ken Choffel 1 Abstract Technological advances in desalination, shifting market conditions, and increasingly
ACTIFLO Process For Wet Weather and Wastewater Treatment
ACTIFLO Process For Wet Weather and Wastewater Treatment ACTIFLO Microsand Ballasted Clarification Process ACTIFLO is a high rate, compact process developed by Veolia Solutions & Technologies. The process
James City Service Authority Five Forks Water Treatment Facility
W e w o r k i n p a r t n e r s h i p w i t h a l l c i t i z e n s t o a c h i e v e a q u a l i t y a n d r e l i a b l e w a t e r s o u r c e. Design Team n Jcsa Owner/Operator n Buchart Horn Prime
Reverse Osmosis Membranes for Wastewater Reclamation By Craig R. Bartels, PhD Hydranautics, 401 Jones Road, Oceanside California, USA 92054
Reverse Osmosis Membranes for Wastewater Reclamation By Craig R. Bartels, PhD Hydranautics, 401 Jones Road, Oceanside California, USA 92054 Abstract Wastewater reclamation has become a viable alternative
Technical Paper Presented at Southwest Chemistry Workshop, Farmington, NM, June 23-24, 2009
Technical Paper Presented at Southwest Chemistry Workshop, Farmington, NM, June 23-24, 2009 Pall Integrated Membrane System Enhances Boiler Feed Water Make-Up Quality and Lowers Operating Costs Ram Karlapudi,
Description of the Water Conserv II Facility
Description of the Water Conserv II Facility Introduction The Water Conserv II (WCII) Water Reclamation Facility provides service to a majority of the southwest section of Orlando. The WCII facility has
Nine Industrial Scale V SEPs. Feed Tank V SEP. Feed Pumps (Three) Concentrate. Tank. V SEP Treatment System
River Treatment for Ultrapure Production A cost-effective and environmentally-sound solution Abstract New Logic International installed its Vibratory Shear Enhanced Processing (VSEP) Phase I system in
Desalination. Reverse Osmosis Multistage Flash Multi-Effect Distillation
Desalination Reverse Osmosis Multistage Flash Multi-Effect Distillation Experience In Motion Supplier to the World Flowserve is the driving force in the global industrial pump marketplace. No other pump
PERFORMANCE TESTING OF A 380 ML/D RETROFITTED MEMBRANE/UV OXIDATION WTP. Introduction
PERFORMANCE TESTING OF A 38 ML/D RETROFITTED MEMBRANE/UV OXIDATION WTP Brian Sahely, M.A.,Sc., P.Eng, AECOM Canada Ltd. 56 Cancross Court, Suite A, Mississauga, ON L5R 3E9 [email protected] Phone:
Innovation and Progress in Water Treatment Technology
Innovation and Progress in Water Treatment Technology Degree of separation of ultrafiltration Summary of the various processes The water will be pressed through the between the raw water side and the filtrate
Water Solutions for Downstream Oil & Gas
Water Solutions for Downstream Oil & Gas WATER TECHNOLOGIES Solutions that ensure your productivity Veolia Water Technologies is dedicated to serving the oil and gas industry globally. With a wide array
Case Study: Optimizing Scale Inhibition Costs in Reverse Osmosis Desalination Plants
Case Study: Optimizing Scale Inhibition Costs in Reverse Osmosis Desalination Plants Mohannad Malki, American Water Chemicals, Inc. Abstract Over the last few decades, advancements in technology and engineering
1. Inspection and monitoring... 3
1 Index 1. Inspection and monitoring... 3 1.1 Handling of new elements... 3 1.1.1 Storage of original packaged RO elements... 3 1.1.2 Packing... 3 1.2 Initial start- up checks of a plant... 3 1.2.1 Preparation
Lenntech. Dow Water Solutions. FILMTEC Membranes. Product Information Catalog
Dow Water Solutions FILMTEC Membranes Product Information Catalog Lenntech [email protected] Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Form No. 609-00204-1108 FILMTEC Membranes 1. Product
DOMESTIC WASTEWATER SYSTEMS
Environmental PROTECTION Systems DOMESTIC WASTEWATER SYSTEMS Highest quality sewage treatment systems from the name you can trust Hynds Aerated Wastewater Systems Hynds Lifestyle Systems are an elite range
AQUAPRO INDUSTRIAL CO.,LTD. Reverse Osmosis Parts Introduction
Reverse Osmosis Parts Introduction Reverse Osmosis Flow Chart AQUAPRO INDUSTRIAL CO.,LTD Triple Membrane WATER IMPROVER WATER IMPROVER 2 Reverse Osmosis Electrical Diagram AC-220V Power (2.0 point) (W)
CHEMICAL CLEANING EXPERIMENTS FOR PERFORMANCE RESTORATION OF NF MEMBRANES OPERATED ON SEAWATER FEED 1
CHEMICAL CLEANING EXPERIMENTS FOR PERFORMANCE RESTORATION OF NF MEMBRANES OPERATED ON SEAWATER FEED 1 A. Mohammed Farooque, Ahamed S. Al-Amoudi and Ata M. Hassan Saline Water Conversion Corporation P.O.Box
Royal Caribbean International Advanced Wastewater Purification Systems
Royal Caribbean International Advanced Wastewater Purification Systems Royal Caribbean International is installing advanced wastewater purification (AWP) systems on all of its ships. These technologically
Appendix B: Water Treatment Scenarios from AMD Treat
Appendix B: Water Treatment Scenarios from AMD Treat 103 of 104 Jeddo Tunnel Abandoned Mine Drainage Passive vs. Active Treatment Cost Estimates Provided by Office of Surface Mining AMD Treat Software
WASTE WATER TREATMENT SYSTEM (OPERATING MANUALS )
Page 1 of 76 1.0 PURPOSE The purpose of the Wastewater Treatment System is to remove contaminates from plant wastewater so that it may be sent to the Final Plant Effluent Tank and eventually discharged
TALLINN WATER TREATMENT AND SEWERAGE Tuuli Myllymaa
TALLINN WATER TREATMENT AND SEWERAGE Tuuli Myllymaa Tallinn is the capital of Estonia. It has approximately 450,000 inhabitants and the town area is about 150 km 2. Tallinn Water Ltd., owned by the City
Practice Tests Answer Keys
Practice Tests Answer Keys COURSE OUTLINE: Module # Name Practice Test included Module 1: Basic Math Refresher Module 2: Fractions, Decimals and Percents Module 3: Measurement Conversions Module 4: Linear,
Advanced Wastewater Treatment and Disposal Systems. Water and Wastewater Utility Operation and
Advanced Wastewater Treatment and Disposal Systems Water and Wastewater Utility Operation and Management for Tribes Preliminary Treatment Primary Treatment Secondary Treatment Tertiary Treatment Disinfection
Water Softening for Hardness Removal. Hardness in Water. Methods of Removing Hardness 5/1/15. WTRG18 Water Softening and Hardness
Water Softening for Removal 1 in Water High concentration of calcium (Ca2+) and magnesium (Mg2+) ions in water cause hardness Generally, water containing more than 100 mg/l of hardness expressed as calcium
Genesee Advanced Water Treatment Facility
Genesee Advanced Water Treatment Facility Preliminary Engineering Report November 3, 2014 Hatch Mott MacDonald 143 Union Blvd., Suite 1000 Lakewood, Colorado 80228 303.831.4700 www.hatchmott.com Advanced
Feasibility study of crystallization process for water softening in a pellet reactor
International A. H. Mahvi, Journal et al. of Environmental Science & Technology Feasibility study of crystallization... Vol. 1, No. 4, pp. 1-4, Winter 5 Feasibility study of crystallization process for
How To Develop A Water Technology Business In Kemira
Johan Grön Executive Vice President, R&D and Technology Environmental technology opportunities Global megatrends Clean water and water intensiveness Global markets and business opportunities Water technology
Iron and Manganese BACTERIA AND IRON AND MANGANESE
Iron and Manganese Iron and manganese control is the most common type of municipal water treatment in Minnesota. Iron and manganese occur naturally in groundwater. Neither element causes adverse heath
Application Note NEW LOGIC RESEARCH. Treating Fuel Storage Tank Bottom Water With VSEP. Overview
Treating Fuel Storage Tank Bottom Water With VSEP Overview Fuel storage tank bottom water (FSTBW) is one of several types of petroleum contaminated wastewater sources that can be treated using V SEP technology.
WASTEWATER TREATMENT OBJECTIVES
WASTEWATER TREATMENT OBJECTIVES The student will do the following: 1. Define wastewater and list components of wastewater. 2. Describe the function of a wastewater treatment plant. 3. Create a wastewater
COMPANY PROFILE & CAPABILITY STATEMENT
COMPANY PROFILE & CAPABILITY STATEMENT November 2014 Contents 1. Introduction... 1 1.1. Corporate Summary... 2 2. Extent of Capabilities... 3 2.1. General... 3 2.2. Water Treatment... 3 2.3. Municipal
Treatment of Arsenic Residuals from Drinking Water Removal Processes
EPA/6/R/33 June 2 Treatment of Arsenic Residuals from Drinking Water Removal Processes by Michael J. MacPhee Gail E. Charles David A. Cornwell Environmental Engineering & Technology, Inc. Newport News,
Troubleshooting Your RO
Troubleshooting Your RO Summary: There can be many reasons why a RO system suffers a loss in performance, and is unable to produce the proper quantity and/or quality of permeate water. Similar to a doctor
Membrane Bioreactor Performance Compared to Conventional Wastewater Treatment
Technical Paper Membrane Bioreactor Performance Compared to Conventional Wastewater Treatment Authors: Thomas C. Schwartz and Brent R. Herring, Woodard and Curran Incorporated Ricardo Bernal and Janet
Flexible Microscreen Filter. Hydrotech Discfilter
Flexible Microscreen Filter Hydrotech Discfilter Hydrotech Discfilter The world s leading microscreen filter is the ideal filtration system for fine solids removal and product recovery thanks to its superior
WATER REUSE IN SPAIN: DATA OVERVIEW AND COSTS ESTIMATION OF SUITABLE TREATMENT TRAINS
INNOVA-MED CONFERENCE Water Reclamation and Reuse 8-9 October 2009, Girona, Spain WATER REUSE IN SPAIN: DATA OVERVIEW AND COSTS ESTIMATION OF SUITABLE TREATMENT TRAINS Raquel Iglesias Esteban (Hydrology
Oasis Clearwater ENVIRONMENTAL SYSTEMS WASTEWATER TREATMENT ENGINEERS
Oasis Clearwater ENVIRONMENTAL SYSTEMS WASTEWATER TREATMENT ENGINEERS The evolution continues in decentralised wastewater technology... The Process Decentralised wastewater treatment systems are defined
PRICE LIST Brutto incl.moms Januar 2011
PRICE LIST Brutto incl.moms Januar 2011 Rev. 1 2011 SELMAR Technologies S.r.l. Reverse Osmosis Watermakers PROGRESS - Thermal circuit breaker - Salinity meter SEL-MC40 15 360 18A-12V (9A-24V) 64 x 25 x
www.ceyka.com.tr KİMYA SANAYİ VE DI TİC.LTD. Tİ.
KİMYA SANAYİ Ceyka is an engineering and international trade company that provides industrial chemicals, recyling plants,water/wastewater/mining chemicals, environmental technologies and equipments. MEMBRANE
Membrane Types and Factors Affecting Membrane Performance
Advanced Membrane Technologies Stanford University, May 07, 2008 Membrane Types and Factors Affecting Membrane Performance Mark Wilf, Ph.D. Tetra Tech Outline Membrane filtration (low pressure applications)
REVERSE OSMOSIS PROCESS AND SYSTEM DESIGN. H. Ohya Department of Chemical Engineering, Yokohama National University, Japan
REVERSE OSMOSIS PROCESS AND SYSTEM DESIGN Y. Taniguchi Water Reuse Promotion Center, Japan H. Ohya Department of Chemical Engineering, Yokohama National University, Japan Keywords : Brine, B-value, Compaction,
CERTIFICATION TO OPERATE WATER AND WASTEWATER TREATMENT SYSTEMS APPLICATION INSTRUCTIONS
COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION STATE BOARD FOR CERTIFICATION OF WATER AND WASTEWATER SYSTEMS OPERATORS CERTIFICATION TO OPERATE WATER AND WASTEWATER TREATMENT SYSTEMS
Water Specialists for the Petrochemical Sector. ovivowater.com. creating value in water through innovation, creativity and expertise
Water Specialists for the Petrochemical Sector creating value in water through innovation, creativity and expertise ovivowater.com Ovivo - Industrial Services A New Global Force in Water As society and
Subject: Technical Letter 22 April 1977 Removal of Water Supply Contaminants -- Copper and Zinc
STATE OF ILLINOIS Department of Registration and Education JOAN G. ANDERSON DIRECTOR. SPRINGFIELD BOARD OF NATURAL RESOURCES AND CONSERVATION JOAN G. ANDERSON CHAIRMAN BIOLOGY THOMAS PARK CHEMISTRY H.
PRINCIPLES AND PRACTICES OF REVERSE OSMOSIS
PRINCIPLES AND PRACTICES OF REVERSE OSMOSIS O.J. Morin Black and Veatch, Florida, USA Keywords : Acidity, Alkaline scale, Anion, Anionic, Antiscalant, Aquifer, Avogadro's number, Brackish water, Buffer,
POTW PHOSPHORUS REMOVAL PROCESSES
POTW PHOSPHORUS REMOVAL PROCESSES Ohio Lake Erie Phosphorus Task Force - December 20, 2007 ROBERT M. BONNETT, PE Northeast Ohio Regional Sewer District OUTLINE SOURCES AND FORMS IN WASTEWATER TYPICAL POTW
Cyanotoxin Removal in Drinking. Recreational Waters. Judy Westrick April 14, 2011 2011 Northeast Regional Cyanobacteria Workshop
Cyanotoxin Removal in Drinking Water Treatment Process and Recreational Waters Judy Westrick April 14, 2011 2011 Northeast Regional Cyanobacteria Workshop NEIWPCC Overview Water Treatment Source and Recreational
Energy Audits Waste Water Treatment Plants
Energy Audits Waste Water Treatment Plants Ohio Water Environment Association Conference June 20, 2012 Presented by: Samuel J. Morgan, P.E., LEED AP CT Consultants, Inc. World Energy Trend US Total Energy