How to use your Water Heater
|
|
|
- Kristin Hubbard
- 9 years ago
- Views:
Transcription
1 How to use your Water Heater Infinity 32 HD 250 E Infinity 26 HD 200 E Infinity 26 Internal HD 200 I Infinity 24 Your installer is responsible for correct installation. Installation instructions are located in a pouch attached to the inside front panel of the water heater. Temperature ontrolled Operation 24 Hr Hot Water In all areas
2 ONTENTS FEATURES & BENEFITS... 2 IMPORTANT INFORMATION... 3 OPERATION WITHOUT TEMPERATURE ONTROLLERS... 7 TEMPERATURE ONTROLLERS... 8 STANDARD TEMPERATURE ONTROLLERS... 9 Using the Infinity with 1 Standard Temperature ontroller Using the Infinity with 2 or more Standard Temperature ontroller To Turn Off your hot water system DELUXE BATHFILL TEMPERATURE ONTROLLERS Deluxe Bathfill Kitchen Temperature ontroller (M-70-2A) Deluxe Bathfill Bathroom Temperature ontroller Monitor Deluxe Bathfill Bathroom Temperature ontroller (B-70-2A) Using the Infinity with 1 Deluxe Bathfill Temperature ontroller Setting the Sound Volume Kitchen Bathfill ontroller Using the Infinity with 2 Deluxe Bathfill Temperature ontrollers Setting the Sound Volume Bathfill Kitchen ontroller Deluxe Bathfill Bathroom ontroller Using the Infinity with 3 Deluxe Bathfill Temperature ontrollers and 1 Standard Temperature ontroller (Infinity 26, Heavy Duty 26 and Heavy Duty 26-Internal Only) Using the Infinity with 3 Deluxe Temperature ontrollers and 1 Standard Temperature ontroller Shower Saver / Bath Fill Function TROUBLE SHOOTING WARRANTY
3 FEATURES AND BENEFITS ongratulations on purchasing the latest in Technology Advanced Temperature ontrolled Rinnai Hot Water System. The Rinnai Infinity NEVER RUNS OUT of hot water. Whilst electricity, water and gas supplies are connected, hot water is available whenever hot water taps are open. Built into the main micro-processor is the facility to LIMIT THE MAXIMUM TEMPERATURE of the hot water supplied. The water temperature may be limited to various maximum temperatures. This is particularly useful when the hot water unit is installed where young children or the infirm may be using the hot water. The Infinity is delivered with a preset temperature of 55. If required, the temperature limits can be changed by an authorised person. For further information, please contact Rinnai. The Rinnai Infinity is a power flued appliance. This makes it OMPAT, saving both floor and wall space. The temperature of outgoing hot water is ONSTANTLY MONITORED by a BUILT-IN SENSOR. If the temperature of the outgoing hot water rises to more than 3 above the selected temperature the burner is turned OFF and only turned ON again when the temperature falls to below the selected temperature. The burner lights automatically when the hot water tap is opened, and goes out when the tap is closed. IGNITION IS ELETRONI, so there is no pilot light. When the hot water tap is off, no gas is used. Deluxe Bathfill or Standard Temperature ontrollers are available as an optional extra. Depending on the models chosen, these offer the following additional features: Localised Temperature ontrollers for up to one kitchen and three bathrooms Bath fill function (Deluxe Bathfill Bathroom ontrol Only) Voice Prompting (Deluxe Bathfill ontrol Only) lock (Deluxe Bathfill ontrol Only) Temperatures selected at the controllers are retained in the SYSTEM MEMORY. Operating NOISE LEVEL IS VERY LOW. ERROR MESSAGES ARE DISPLAYED on the Temperature ontrollers, assisting with service
4 IMPORTANT INFORMATION Always check water temperature by hand before entering the shower or bath. At low water flows, the hot water unit may go out without warning. OFF If freezing conditions are expected, turn off water and gas, and drain all water from the appliance. Do not touch the unit cover or the flue outlet. Do not insert objects into the flue outlet. Water Off Gas Off Drain Water If power and the automatic frost protection are connected, freezing will be prevented. ( K Series only) DRAIN FILTER WATER GAS Keep flammable materials, trees, shrubs etc. away from the flue outlet. EXTERNAL INTERNAL On cold days steam may be discharged from the flue outlet. This is normal with a high efficiency appliance and does not indicate a fault. The hot water unit controls the water temperature automatically. To do this it sometimes needs to change the water flow accordingly. The water flow from the hot water tap may vary after the selected temperature at the Temperature ontroller is altered. The water flow may also vary from summer to winter, as incoming water temperatures differ. EXTERNAL INTERNAL 48º 55º Do not spray water directly into the flue terminal
5 IMPORTANT INFORMATION Do not clean the Temperature ontrol with solvents. Use a soft damp cloth. When the hot water tap is open, and hot water is flowing, the water temperature can only be increased to a maximum of 43 on the Temperature ontroller with priority. 43 o ONLY Depending on the weather conditions and the length of the pipe between the hot water unit and the tap in use, there may be a variation between the temperatures displayed at the Temperature ontroller(s) and the temperature of the water at the tap. There is no need to turn the Temperature ontroller(s) off after use. However, if you prefer to turn the Temperature ontroller(s) off, selected temperatures will be stored in the system memory at all times whilst mains power remains connected. 48 If a temperature is higher than 50, and has been selected at the Kitchen ontroller and then priority of temperature selection is transferred to a Bathroom ontroller and back again, the temperature on the Kitchen ontroller will drop to 50. This is a safety feature. Do not push the ON/OFF button on the Kitchen ontroller after having transferred priority of temperature selection to the Bathroom ontroller as the system will no longer heat the water. Turn OFF then ON. WARNING Someone may be about to enter a shower or fill the bath
6 IMPORTANT New Zealand has a service and spare parts network in all areas. Our Service network personnel are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance needs service, please ring the 0800 Rinnai service contact number on the back of this booklet. Rinnai recommend that this appliance should be serviced every 3 years. This appliance shall be installed in accordance with: Manufacturer s Installation Instructions. urrent AS/NZS urrent AS/NZS 3000 Local Water Authority Regulations. Local Gas Fitting Regulations. Municipal Building odes. NZS 5261 Gas Appliance Installation ode. Any other relevant Statutory Regulations. This Infinity must be installed correctly by an authorized person. The installation of gas, water, and electricity must conform to local regulations. The installation must also comply with the instructions supplied by Rinnai. Your heater has been approved by the Australian Gas Association A.G.A. Approval Number shown on Data plate. Please keep this instruction booklet in a safe place for future reference. All dimensions referred to in these instructions are in millimeters, unless otherwise specified. N10378 Distributed and Serviced in Australia under a Quality system certified as complying with ISO 9002 by Standards Australia Quality Assurance Services - 5 -
7 IMPORTANT INFORMATION Excessively hot water is dangerous, especially for young children and the infirm. The Infinity allows you to control the temperature of your hot water to safe levels. DANGER Water temperatures over 50 can cause severe burns instantly or death from scalds. hildren, disabled, and the elderly are at highest risk of being scalded. Feel water before bathing or showering. HOT BURN Burns from hot water taps can result in very severe injuries to young children. Hot water at 65 (the average hot water temperature in New Zealand) can severely burn a child in less than half a second. At 50 it takes five minutes. Burns can occur when children are exposed directly to hot water or when they are placed into a bath which is too hot. DO DON T Do stay with children whenever they are in the bathroom. (Take the phone off the hook). Do take them out of the bathroom if you need to answer the phone or door. Do test the temperature of the water with your elbow before placing your child in the bath. Do make sure that the tap is turned off tightly. Do consider setting your Infinity at a maximum temp. of 50. (ontact Rinnai New Zealand) Do install a child proof tap cover OR, Do install a child resistant tap. Don t leave a toddler in the care of another small child. The older child may not have set the water temperature to a safe level. onsider child-resistant taps or inexpensive tap covers, both of which prevent a small hand being able to turn on the tap. onsider reducing the temperature of the water coming from the hot water tap to 50. This approach can be extremely valuable because it requires a one time action for a longterm reduction in the risk of scalds. This type of automatic protection is important during times when a parent or carer has been distracted
8 OPERATION WITHOUT TEMPERATURE ONTROLLERS The Infinity has no pilot light and when installed without Temperature ontrollers, the Infinity will operate automatically as soon as a hot water tap is opened. The burner ignites with electronic ignition and the flame extinguishes as soon as water flowing through the appliance stops. Simply, open a hot water tap. HOT OLD 55 The Infinity is factory pre-set to 55. If you require greater control over the temperature of your hot water, contact Rinnai about our temperature controllers to allow precise digital temperature control in the range 37 ~ 55. ontrollers can be easily fitted at any time after installation
9 TEMPERATURE ONTROLLERS The purpose of the Temperature ontrollers is to enable the user to have complete control over the hot water unit. Used correctly, the hot water unit will supply hot water at the temperature selected, even when the water flow is varied, or when more than one tap is used. Adjustments to the operation of your hot water unit can be made with any of the Temperature ontrollers. Each Temperature ontroller can be individually programmed. Various water temperatures ( ) can be selected as follows: Kitchen ontroller: 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 48, 50, 55 Bathroom ontroller Hot Water Delivery: 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 48, 50 Bath fill Delivery: 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48 If a temperature between 43 and 50 is selected on a Bathroom ontroller and this temperature is then decreased to below 43 and increased again whilst the water is running, the maximum selectable temperature will become 43. This provides additional safety for the consumer. Suggested temperatures are: Kitchen 50 Shower 42 Bath fill 40 These temperatures are suggested starting points for selection. You may find higher or lower temperatures are more comfortable. Maintaining lower temperatures helps to save energy. To obtain water temperatures lower than 37 simply add cold water. Temperature ontrollers are an optional extra. Standard and Deluxe Bathfill Temperature ontrollers can be fitted. Standard ontrollers allow temperature selection only. Deluxe Bathfill ontrollers have temperature selection, bath fill and clock functions. Temperature ontrollers allow the temperature to be set from various locations. The temperature selected will be available to all outlets. ontroller Options Model Infinity 26 Infinity 32 Infinity 24 Deluxe Bathfill Temperature ontrollers M-70-2A, B-70-2A, Standard Temperature ontrollers M-91-1A - 8 -
10 STANDARD TEMPERATURE ONTROLLER Standard Kitchen Temperature ontroller (M-91-1A) Temperature ontrollers are not required to operate the Infinity unit. They are an optional extra providing control of water temperature. Up to 4 Standard ontrollers can be fitted to one Infinity unit. They are normally installed in the areas where the majority of hot water is used, for example, the kitchen, bathroom, ensuite and laundry. Instead of the laundry, the 4 th ontroller could also be installed in the toilet or additional bathroom
11 OPERATION WITH STANDARD TEMPERATURE ONTROLLERS Using the Infinity with 1 Standard Temperature ontroller Press the ON/OFF button on the Temperature ontroller. The yellow ON indicator will glow on the Temperature ontroller. This indicates that the hot water unit is ready to supply hot water when a tap is open. To operate the hot water unit, simply turn any hot water tap on. This will automatically light the burner providing hot water. The red IN USE indicator will glow on the Temperature ontroller. Adjusting Temperature Simply press the HOTTER or OOLER button until the required temperature is displayed on the Digital Monitor. AUTION HEK WATER TEMPERATURE BEFORE USE. A parent should always check the temperature before a child is placed in contact with hot water. When any hot water tap is open, temperature cannot be adjusted except between 37 and 43. For safety reasons, temperature priority cannot be transferred between controllers when a hot water tap is open
12 OPERATION WITH STANDARD TEMPERATURE ONTROLLERS Using the Infinity with 2 or more Standard Temperature ontrollers Switching the System ON : The hot water system and all controllers can be switched ON and OFF from any controller by pressing the ON/OFF Button as shown. When the system is turned ON the water Temperature display will be lit. During normal operation the system is left ON. Using Hot Water Ensure the system is switched ON. When the system is ON, the temperature displays will be lit. Ensure the transfer button is lit. If not press the TRANSFER button once. This will transfer priority to this controller which will then have control of the water delivery temperature. Select the desired temperature using the hot water temp buttons. The selected temperature will be displayed on all controller monitors. This is the water temperature which will be supplied to all outlets. Temperatures no higher than 50 should be able to be selected on controllers installed in bathrooms, ensuites or toilets. This is to help reduce the risk of burns from hot water. If this is not the case, the controllers have been incorrectly installed. ONTAT YOUR INSTALLER. Open the Hot Water Tap. The Infinity unit will be activated and the in use indicator will light up. HOT OLD When any hot water tap is open, temperature can not be adjusted except between 37º and 43º. For safety reasons, temperature priority can not be transferred between controllers when hot water tap is open
13 OPERATION WITH STANDARD TEMPERATURE ONTROLLERS To TURN OFF your hot water system During normal operation the system is left ON. Simply press the ON/OFF button on any Temperature ontroller (where fitted). This will shut the Infinity down completely including the Temperature ontroller digital displays. The ON indicator will go out. If hot water taps are opened when the Infinity is OFF, cold water will flow from the taps. Additional SAFETY features Whilst the hot water tap is open, the following safety features apply. Temperature selection cannot be transferred. Water temperature can only be adjusted between 37 and 43 from the controller that has control. Other controllers are unable to change the delivery temperature of the water heater. The temperature of outgoing hot water is constantly monitored by a built-in sensor. If the temperature of the outgoing hot water rises to more than 3 above the selected temperature shown on the Digital Monitor or the pre-set limit when Temperature ontrollers are not fitted, the burner will automatically go out. The red operation indicator will also go out. The burner will ignite again once the outgoing hot water temperature falls to that shown on the Digital Monitor (or the pre-set limit of the Infinity unit)
14 DELUXE BATHFILL TEMPERATURE ONTROLLER Deluxe Bathfill Kitchen Temperature ontroller Monitor Each time a button is pressed, a beep will sound. The beep sound and the bath fill complete buzzer can be muted by pressing the Temperature ontroller Up and Down buttons simultaneously for more than 3 seconds. This can be done for each Temperature ontroller. To return to original settings, repeat this step
15 DELUXE BATHFILL TEMPERATURE ONTROLLER Deluxe Bathfill Kitchen Temperature ontroller (M-70-2A) This temperature controller is installed in the kitchen. Each button confirms its operation with a beep and / or voice. AUTION Be careful not to get water in the speaker as it may cause damage
16 DELUXE BATHFILL TEMPERATURE ONTROLLER Deluxe Bathfill Bathroom Temperature ontroller Monitor Each time a button is pressed, a beep will sound. The beep sound and the bath fill complete buzzer can be muted by pressing the Temperature ontroller Up and Down buttons simultaneously for more than 3 seconds. This can be done for each Temperature ontroller. To return to original settings, repeat this step
17 DELUXE BATHFILL TEMPERATURE ONTROLLER Deluxe Bathfill Bathroom Temperature ontroller (B-70-2A) This temperature controller is installed in the bathroom. Each button confirms its operation with a beep and / or voice. AUTION Be careful not to get water in the speaker as it may cause damage
18 ON/OFF ON/OFF ON/OFF M -70-1A M -70-1A DELUXE BATHFILL TEMPERATURE ONTROLLERS Using the Infinity with 1 Deluxe Bathfill Temperature ontroller When one Temperature ontroller is required, the kitchen model must be used (M-70-2A). Transfer lock Hour Min. Hot water temp. Sound ooler Hotter Switching the system ON The hot water system and controller can be switched on and off pressing the ON/OFF button as shown. When the system is turned on, the monitor will be lit. During normal operation the system is left on. Transfer Hot water temp. lock Hour Min. Sound ooler Hotter Setting the lock The clock is of the 12 hour /PM type. Press the lock button. The digital monitor will flash 12:00. lock Hour Min. ON/OFF Sound Set the time using the Hour and Min. buttons. The time is displayed on the monitor as the buttons are pressed. The numbers on the monitor will continuously change if you keep the buttons depressed. When you get close to the desired time, press the button intermittently. lock Hour Min. Sound Press the lock button again to activate the clock. lock Hour Min. ON/OFF Sound The time is always displayed regardless of whether the Temperature ontroller is turned ON or OFF. The clock may need to be reset after a power failure
19 M -70-1A M -70-1A DELUXE BATHFILL TEMPERATURE ONTROLLERS Setting the Sound Volume The Sound Button located behind the flip panel is not used when one Kitchen ontroller is connected. Using Hot Water The hot water delivery temperature can be controlled from the Kitchen ontroller (M-70-2A). lock Hour Min. Transfer Hot water temp. ON/OFF Sound ooler Hotter Ensure the system is switched ON. If not, press the ON/OFF button behind the flip panel once. The Transfer button will light up. Select the desired temperature using the Hot water temp. buttons. The selected temperature will be displayed on the controller monitor. ON/OFF Transfer Hot water temp. lock Hour Min. Sound ooler Hotter Open the hot water tap. The hot water unit will activate and the red combustion symbol will light up on the monitor. HOT OLD AUTION HEK WATER TEMPERATURE BEFORE USE. A parent should always check the temperature before a child is placed in contact with hot water. When any hot water tap is open, temperature cannot be adjusted except between 37 and 43. For safety reasons, temperature priority cannot be transferred between controllers when a hot water tap is open
20 ON/OFF ON/OFF M -70-1A M -70-1A OPERATION WITH DELUXE BATHFILL TEMPERATURE ONTROLLERS Using the Infinity with 2 Deluxe Bathfill Temperature ontrollers When 2 Temperature ontrollers are used, they must be models M-70-2A (Kitchen) and B-70-2A (Bathroom). Transfer Hot water temp. lock Hour Min. Sound ooler Hotter Switching the System ON The hot water system and both controllers can be switched on and off from either controllers by pressing the ON/OFF button as shown. When the system is turned on, the monitor will be lit. During normal operation the system is left on. Transfer Hot water temp. lock Hour Min. Sound ooler Hotter Setting the lock The clock is of the 12 hour /PM type and is set on the Kitchen ontroller (M-70-2A). lock Hour Min. Sound Press the lock button. The digital monitor will flash 12:00. Set the time using the Hour and Min. buttons. The time is displayed on the monitor as the buttons are pressed. The numbers on the monitor will continuously change if you keep the buttons depressed. When you get close to the desired time, press the button intermittently. lock Hour Min. Sound lock Hour Min. Press the lock button again to activate the clock. ON/OFF Sound The time displayed on the Kitchen ontroller is automatically displayed on all Bathroom ontroller(s) when the Bathroom ontroller(s) are ON. If the controllers are OFF, the time is only displayed on the Kitchen ontroller. The clock may need to be reset after a power failure
21 ON/OFF M -70-1A ON/OFF ON/OFF M -70-1A M -70-1A OPERATION WITH DELUXE BATHFILL TEMPERATURE ONTROLLERS Setting the Sound Volume The sound volume for all Temperature ontrollers can be set individually. Note that this can be done with the Temperature ontrollers switched off. Press the Sound Button located behind the flip panel. Transfer lock Hour Min. Hot water temp. Sound ooler Hotter The volume will change as follows: Using Hot Water Voice Volume Initial Setting Medium Press Once High Press Again Off Press Again Low The hot water delivery temperature can be controlled from either the Kitchen ontroller (M-70-2A) or the Bathroom ontroller (B-70-2A). Deluxe Bathfill Kitchen ontroller Transfer Ensure the system is switched on. When the system is ON, the monitors will be lit. ensure the Transfer button is lit. If not, press the Transfer button once. Select the desired temperature using the Hot water temp. buttons. The selected temperature will be displayed on both the Kitchen and Bathroom ontrollers at the top of each monitor. Open the hot water tap. The hot water unit will activate and the red combustion symbol will light on both the kitchen and bathroom monitors. Hot water temp. lock Hour Min. Sound ooler Hotter Transfer Hot water temp. lock Hour Min. Sound ooler Hotter AUTION HEK WATER TEMPERATURE BEFORE USE. A parent should always check the temperature before a child is placed in contact with hot water. HOT OLD When any hot water tap is open, temperature cannot be adjusted except between 37 and 43. For safety reasons, temperature priority cannot be transferred between controllers when a hot water tap is open
22 OPERATION WITH DELUXE BATHFILL TEMPERATURE ONTROLLERS Deluxe Bathfill Bathroom ontroller Ensure the system is switched ON. When the system is ON, the monitors will be lit. Ensure the Transfer button is lit. If not, press the Transfer button once. Select the desired temperature using the Hot water temp. buttons. The selected temperature will be displayed at the top of all controller monitors. Open the hot water tap. The hot water unit will activate and the red combustion symbol will light on both bathroom and HOT OLD kitchen monitors. AUTION HEK WATER TEMPERATURE BEFORE USE. A parent should always check the temperature before a child is placed in contact with hot water. When any hot water tap is open, temperature cannot be adjusted except between 37 and 43. For safety reasons, temperature priority cannot be transferred between controllers when a hot water tap is open The Shower Saver / Bath fill function enables a shower to be run for desired period or a bath to be filled to the desired level at the desired temperature automatically. There are 2 steps to perform : Step 1. Program the shower / bath volume and temperature into the Bathroom ontroller(s) (B-70-2A). Step 2. Activate the automatic Shower Saver / Bath fill function and follow the voice prompts. AUTION When using the Shower Saver / Bath fill function to fill a bath for the first few times, it is recommended that you are present during the filling process. Step 1 - Programming the bath volume and temperature When the controllers are first turned on, the default shower / bath fill temperature is 40 o and the shower / bath volume is 30 litres (indicated by the first level marker at the bottom of the monitor). The shower / bath volume can then be changed up to a maximum of 400. These settings are displayed at the bottom of the Bathroom ontroller monitor and can be changed by the user as described as follows
23 OPERATION WITH DELUXE BATHFILL TEMPERATURE ONTROLLERS (a) Ensure the system is switched ON. When the system is ON, the monitors will be lit. Ensure the Transfer button is lit. If not, press the Transfer button once. (b) Select the desired temperature using the Shower / Bath temp. buttons located behind the flip panel. The selected temperature will be displayed on the bottom of the bathroom controller monitor and will remain until it is next changed. (c) Select the desired shower / bath volume using the Water Buttons located behind the flip panel. The selected volume will be displayed at the bottom of the bathroom controller monitor numerically, and graphically by the long bar against the level markers. During the first bath fill, it is recommended that the lowest bath fill volume is used. During subsequent bath fills this can be increased depending on the volume of your bath and the desired level. The relationship between shower / bath volume in litres and the position of the long bar against the level markers is as follows. Eg. 120 litres denoted numerically and by the second level marker from the bottom of the monitor, as shown below. Volume (L) Position of long bar & 60 litre option 1 not available on the 1 infinity 24 Remember that the bath level markers on the display are not a true representation of your bath. ie. the half-way mark on the monitor is not necessarily the half-way mark on your bath. The average bath size is 160 litres. Be careful not to overfill the bath! (d) After approx. 5 seconds, the numeric volume displayed will revert to the shower saver / bath fill temperature previously set. The long bar on the level markers will remain
24 OPERATION WITH DELUXE BATHFILL TEMPERATURE ONTROLLERS Step 2 Activate the automatic Shower saver / Bath fill function and follow the voice prompts. (a) Ensure the system is switched on. When the system is ON, the monitors will be lit. Ensure the Transfer button is lit. If not, press the Transfer button once. (b) Press Shower Saver / Bath fill button. The Shower Saver / Bath fill button will light up and the buzzer will sound. The Bath indicator on the Kitchen ontroller monitor will light up. The voice will say The hot water system is ready. Open the hot water tap. (c) Open the hot water tap for the shower or bath. The combustion indicator on all Temperature ontroller(s) will light up and the shower will run or the bath will start to fill. AUTION HEK WATER TEMPERATURE BEFOR USE. A parent should always check the temperature before a hild is placed in contact with hot water. During Shower Saver / Bath fill, the time display on the Bathroom ontroller will show the remaining shower / bath fill volume and will count down the volume remaining. If you wish to stop the water flow whilst the shower saver / bath fill function is in operation, simply press the Shower Saver / Bath fill button. The Shower Saver / Bath fill button If you wish to stop the water flow whilst the shower saver / bath fill function is in operation, simply press the Shower Saver / Bath fill button. The Shower Saver / Bath fill button will flash and the voice will say Turn off all hot water taps and press the Bath fill button. Follow these instructions. (d) When the shower / bath fill is finished to the programmed volume & temperature (see Step 1 ): the flow from the shower / bath hot water tap will stop; the Shower Saver / Bath fill button on the Bathroom ontroller(s) and the Bath indicator on the Kitchen ontroller monitor will flash; the buzzer will sound; the voice will say Bath fill is complete. Turn off the bath hot water tap and push the Bath button. (e) IMPORTANT When filling a bath, close the hot water tap for the bath when the bath is full. This is very important to prevent over filling of the bath. (f) Press the Shower Saver / Bath fill button. This is also important. It tells the hot water unit that the customer is aware that the shower or bath fill function has been completed and that the hot water tap for the shower or bath has been shut. The hot water unit will not allow hot water to flow from any fixture until the Shower / Bath fill button has been pressed. The Shower Saver / Bath fill button light on the Bathroom ontroller and the Bath indicator on the Kitchen ontroller monitor will go out. AUTION NEVER LEAVE YOUNG HILDREN UNATTENDED IN THE BATH. When using the Shower saver / Bath fill function, ALWAYS close the hot water tap for the bath after the bath has filled and flow has stopped
25 ON/OFF ON/OFF M -70-1A M -70-1A OPERATION WITH DELUXE BATHFILL TEMPERATURE ONTROLLERS Using the Infinity with 3 Deluxe Bathfill Temperature ontrollers (Not available for use with Infinity 24 models) When 2 or 3 Temperature ontrollers are used for the Infinity, there must be one M-70-2A (Kitchen) and two B-70-2A (Bathroom). Transfer lock Hour Min. Hot water temp. Sound ooler Hotter Switching the System On The hot water system and three controllers can be switched on and off from any controller by pressing the ON/OFF button as shown. When the system is turned on, the monitors will be lit. During normal operation the system is left on. Transfer lock Hour Min. Hot water temp. Sound ooler Hotter Setting the clock See page 21 for details on setting the clock. Setting the Sound Volume See page 22 for details on setting the sound volume. Using Hot Water The hot water delivery temperature can be controlled from either the Kitchen ontroller (M-70-2A) or Bathroom ontrollers (B-70-2A). See pages 21 to 22 for details on setting the hot water delivery temperature for the Kitchen and Bathroom ontrollers. Shower Saver Bath Fill Function See pages 22 to 24 for details on the Shower Saver / Bath fill function. With two or more Bathroom ontrollers fitted (one in each bathroom) only one bath can be filled at a time. AUTION HEK WATER TEMPERATURE BEFORE USE. A parent should always check the temperature before a child is placed in contact with hot water. When any hot water tap is open, temperature cannot be adjusted except between 37 and 43. For safety reasons, temperature priority cannot be transferred between controllers when a hot water tap is open Repeat the relevant procedures above for the third (Bathroom) ontroller
26 ON/OFF ON/OFF M -70-1A M -70-1A OPERATION WITH DELUXE BATHFILL TEMPERATURE ONTROLLERS Using the Infinity with 3 Deluxe Bathfill Temperature ontrollers and 1 Standard Temperature ontroller (Infinity 26, Heavy Duty 26 & Heavy Duty 26 - Internal only) When 3 to 4 Temperature ontrollers are used for the Infinity, there must be one M-70-2A (Kitchen), one or two B-70-2A (Bathroom), and one M-91-1A (Standard). Transfer lock Hour Min. Hot water temp. Sound ooler Hotter Switching the System On The hot water system and three controllers can be switched on and off from any controller by pressing the ON/OFF button as shown. When the system is turned on, the monitors will be lit. During normal operation the system is left on. Transfer lock Hour Min. Hot water temp. Sound ooler Hotter Setting the clock See page 21 for details on setting the clock. Setting the Sound Volume See page 22 for details on setting the sound volume. Using Hot Water The hot water delivery temperature can be controlled from the Kitchen ontroller (M-70-2A), Bathroom ontroller (B-70-2A) or Standard ontroller (M-91-1A). See pages 21 to 22 and page 10 for details on setting the hot water delivery temperature for the Kitchen and Bathroom ontrollers. Shower Saver / Bath Fill Function The Shower saver / Bath fill function can only be used on Temperature ontroller B-70-2A. See pages 22 to 24 for details on the Bath fill function. AUTION HEK WATER TEMPERATURE BEFORE USE. A parent should always check the temperature before a child is placed in contact with hot water. When any hot water tap is open, temperature cannot be adjusted except between 37 and 43. For safety reasons, temperature priority cannot be transferred between controllers when a hot water tap is open
27 TROUBLESHOOTING The hot water unit has the ability to check its own operation continuously. If a fault occurs, an Error ode will flash on the Digital Monitor if you have Temperature ontrollers. This assists with diagnosing the fault, and may enable you to overcome a problem without a service call. Please quote the code displayed when enquiring about service. (Refer to Warranty page for Warranty onditions.) ode Fault Remedy Displayed - Noticeable reduction in water flow Inlet water filter needs to be cleaned. Service call.** 03 Power interruption during Bath fill (water will not flow on power Turn off all hot water taps. Press ON/OFF twice. reinstatement) 10 Air intake or flue blocked Service all 11 No ignition / No gas supply heck gas is turned on at water heater and gas meter or cylinder. * ** 12 Flame Failure / Low gas flow heck gas is turned on at water heater and gas meter. heck that nothing is obstructing flue outlet. Turn on gas supply to water heater.* 14 Remaining Flame Safety Device Service all 16 Over Temperature Warning Service all 32 Outgoing Water Temperature Sensor Service all Faulty 33 Heat Exchanger Outlet Sensor Faulty Service all 52 Gas Modulating Valve Faulty Service all 61 ombustion Fan Failure Service all 65 Water Flow ontrol Faulty Service all (does not stop flow properly) 71 Micro-processor Failure Service all 72 Micro-processor Failure Service all * In all cases, you may be able to clear the Error ode simply by turning the hot water tap OFF, then ON again. If this does not clear the Error ode, try pushing the ON/OFF button OFF, then ON again. If the Error ode still remains, contact Rinnai or your nearest service agent for advice. ** Faults caused by insufficient gas/water supply or gas/water quality and installation errors are not covered by the manufacturer s warranty. Troubleshooting Without ontrollers If you have no Temperature ontrollers and experience the following symptoms, please carry out the suggestions below. If the symptom continues, please contact Rinnai for advice. Fault The unit does not attempt to start at all. The unit starts then shuts down immediately. The unit starts then the water goes cold Remedy heck the power is on at the unit. heck the cold water valve at the unit is on. heck the power is still on. heck the gas valve at the unit and the gas meter is fully open.** Open your hot water tap fully. heck the power is still on. Open your hot water tap further or try another tap. (Your unit has a minimum flow of 3L/min. required to operate the unit.) ** Faults caused by insufficient gas/water supply or gas/water quality and installation errors are not covered by the manufacturer s warranty
28 WARRANTY The benefits conferred by this warranty are in addition to all other rights and remedies in respect of the product which you have under the Trade Practices Act and similar State or Territory Laws. Given installation is in accordance with the manufacturers specification, this appliance is warranted by Rinnai for the cost of labour and components in the event of defects arising from faulty materials and/or workmanship with the ensuing warranty conditions. Domestic Use : Labour : Parts : ommercial Use : Labour : Parts : Heat Exchanger 3 Years 10 Years (pro-rata) Heat Exchanger 3 Year 5 Year (pro-rata) All Other Parts 3 Years 3 Years All Other Parts 3 Year 3 Year *All terms are effective from date of purchase. Faults arising from improper installation, gas supply, water quality *, plumbing fittings and other outside influences are not the responsibility of Rinnai Australia and service calls for these issues will be charged for. * The recommended water quality levels are as follows: Description Maximum Recommended Levels ph 6.5 to 9 TDS (Totally dissolved solids) Up to 600 mg/litre Total Hardness Up to 200 mg/litre hlorides Magnesium alcium Sodium Iron Up to 300mg/litre Up to 10 mg/litre Up to 20 mg/litre Up to 150 mg/litre Up to 1 mg/litre Please record below the following information for your own records. Your Retailer : Address : Phone : Date of Purchase : Your Installer : Installer s License No. : Address : Phone : Date of Installation : ertificate of ompliance No. : Model No. : REU _ Serial No. : Please remember to send in your Warranty ard. SERVIE ONTAT POINTS RINNAI NEW ZEALAND LTD. 691 MT ALBERT RD ROYAL OAK AUKLAND PO BOX AUKLAND PHONE (09) FAX (09) National Hot Water Service 0800Rinnai Website: [email protected]
Continuous Flow Water Heaters
Operation Manual Continuous Flow Water Heaters For Rinnai continuous flow water heaters manufactured from 2010 onwards (serial number 09.12 xxxxxx) Internal Rinnai continuous flow water heaters must be
Operation / Installation Manual
Operation / Installation Manual Rinnai continuous flow water heaters To Suit Water Heater Models - INFINITY 32 REU-VR3237WG INFINITY 26 REU-VR2626WG INFINITY 26 Plus REU-VRM2630WD INFINITY 26i REU-VR2632FFUG
Owner s Guide and Installation Instructions
Owner s Guide and Installation Instructions Continuous Flow Gas Water Heater 874, 876 series 612 to 620, E16 models This water heater must be installed and serviced by a qualified person. Please leave
Owner s Guide and Installation Instructions
Owner s Guide and Installation Instructions Electronic Continuous Flow Gas Indoor Water Heater 864, series 027 models INSTALLER: The ONLY suitable flue parts are certified Rheem coaxial flue components
ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user
For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents
Owner s Guide and Installation Instructions Continuous Flow Gas Water Heater 884, 886 series 024 models
Owner s Guide and Installation Instructions Continuous Flow Gas Water Heater 884, 886 series 024 models This water heater must be installed and serviced by a qualified person. Please leave this guide with
Owner s Guide and Installation Instructions
Owner s Guide and Installation Instructions Continuous Flow Gas Water Heater 871, 875 Series 624, E24, E26 Models This water heater must be installed and serviced by a qualified person. Please leave this
WARRANTY BOOKLET. Commercial Water Heaters. Register online at www.rinnai.com.au
WARRANTY BOOKLET Commercial Water Heaters Register online at www.rinnai.com.au Rinnai Commercial Water Heating Products Warranty Warranty Terms The benefits to the consumer given by this warranty are
WARRANTY BOOKLET. Continuous Flow Water Heaters. Register online at www.rinnai.com.au
WARRANTY BOOKLET Continuous Flow Water Heaters Register online at www.rinnai.com.au Rinnai Continuous Flow Water Heating Products Warranty Warranty Terms The benefits to the consumer given by this warranty
User's Instructions. Alpha HE CB25/33 and HE SY25
User's Instructions Alpha HE CB25/33 and HE SY25 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Boiler Range For Technical help or for Service call... ALPHA HELPLINE Tel:
For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
Baxi Combi 80e & 105e
Baxi Combi 8e & 15e Please keep these instructions safe. Should you move house, please hand them over to the next occupier. Gas Fired Wall Mounted Combination Boiler User s Operating Instructions Natural
Continuous Flow Water Heaters
WARRANTY BOOKLET Continuous Flow Water Heaters Register online at www.rinnai.com.au Rinnai Continuous Flow Water Heating Products Warranty Warranty Terms The benefits to the consumer given by this warranty
E-gas Instant Gas Water Heaters
The Proven Preferred Choice! E-gas Instant Gas Water Heaters Training & Information Manual: There are important functional and operational differences between the conventional hot water geyser and the
Endless Hot Water 24/7
Endless Hot Water 24/7 Chromagen Continuous Flow Gas Water Heaters Live in eternal comfort with endless, efficient hot water from Eternity Get hot water on demand with an Eternity continuous flow gas water
8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en
8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................
Troubleshoot resources for homeowner http://waterheatertimer.org/troubleshoot-bosch-tankless-water-heater.html
Troubleshoot resources for homeowner http://waterheatertimer.org/troubleshoot-bosch-tankless-water-heater.html Installation / Operating Instructions GOOD.BEETER>BOSCH Water Wizard 600 Continuous Flow Gas
Owner s Guide and Installation Instructions Continuous Flow Gas Water Heater CG26 series
Owner s Guide and Installation Instructions Continuous Flow Gas Water Heater CG26 series This water heater must be installed and serviced by a qualified person. Please leave this guide with the householder.
USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...
2 Contents Components Attachments Guidance Installation Operation Maintenance Service Technical Troubleshooting Symbols used to mark instructions...3 Included Attachments...4 Congratulations...5 Getting
Service Manual. REU-VR2632FFUD - 26i REU-VR2632 FFU-HD-E- HD50i. Continuous Flow Water Heater. Important.
Service Manual REU-VR2632FFUD - 26i REU-VR2632 FFU-HD-E- HD50i Continuous Flow Water Heater Important. Read these instructions carefully before attempting installation or use of this appliance. All work
Bosch Temperature Controllers Operation HANDBOOK
MODELS YPRM67XBN-Main Controller (Premium) YPRS67XBN -Bathroom Controller (Premium) YPRM66XB -Main Controller (standard) YPRS66XB -Bathroom Controller (standard) YPRM67XB -Main Controller (Premium) YPRS67XB
USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book
USERS GUIDE LOGIC Heat 12, 15, 18, 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
For the owner. Instructions for use. ecotec. Wall hung room sealed fan assisted condensing boilers
For the owner Instructions for use ecotec Wall hung room sealed fan assisted condensing boilers GB Contents Specified use Notes on these instructions Specified use... Notes on these instructions.... Storage
Bradlee Boilers Ltd. Instruction Manual for starting up Bradlee Hire Boiler from Cold
Bradlee Boilers Ltd Instruction Manual for starting up Bradlee Hire Boiler from Cold To be read in conjunction with Bradlee Boiler guide to Commissioning Boilers Document Ref: HM001 1. Ensure that all
Response: The combi boiler. Response: The fit anywhere combi
Response: The combi boiler The Ideal Response is a wall mounted, fanned flue combination boiler which serves a home's central heating system and delivers hot water on demand. It has been designed to be
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler
User s Operating Instructions & Important Warranty Information Baxi Platinum Combi HE Range Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move house,
AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T
Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler
User s Operating Instructions Baxi Combi Instant 8e & 15e Gas Fired Wall Mounted Combination Boiler Please keep these instructions safe. Should you move house, please hand them over to the next occupier.
Operation / Installation Manual
Operation / Installation Manual To Suit Models: REU-V2520FFU... R53 REU-V2520FFUC... C53 REU-V2532FFU... R85 REU-V2532FFUC... C85 REU-V2520FFUD... R53PLUS REU-V2520FFUCD... C53PLUS REU-V2532FFUD... R85PLUS
Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler
User s Operating Instructions Baxi Combi 130 HE Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move house, please hand them over to the next occupier.
CONTINUOUS FLOW HOT WATER
CONTINUOUS FLOW HOT WATER THE RINNAI INFINITY STORY SO FAR... In the early 2004 s Rinnai launched the first fully electronic gas continuous flow hot water system in Malaysia. Appropriately named the Rinnai
2 YEAR WARRANTY S7200PAU USE & CARE MANUAL ADVANCED CERAMIC TECHNOLOGY. To register your product go to www.remington-products.com.
USE & CARE MANUAL PLEASE READ PRIOR TO USE To register your product go to www.remington-products.com.au ADVANCED CERAMIC TECHNOLOGY 2 YEAR WARRANTY S7200PAU 1 IMPORTANT SAFEGUARDS Warning: When the straightener
BoilerMate SP. benchmark. user instructions A - C L A S S
A - C L A S S BoilerMate SP user instructions benchmark TM The code of practice for the installation, commissioning & servicing of central heating systems In the interest of continuously improving the
NOW 6 STAR EFFICIENT. factor RHEEM CONTINUOUS FLOW GAS HOT WATER HOT WATER THAT NEVER RUNS OUT YEAR WARRANTY L/MIN ENERGY GAS
RHEEM CONTINUOUS FLOW GAS HOT WATER REVISED MAY 2013 GAS 6 ENERGY RATING 1-6 PERSONS 12-54 L/MIN CAPACITY 10 YEAR WARRANTY 3 NOW 6 STAR EFFICIENT HOT WATER THAT NEVER RUNS OUT factor COMES ON STEADY, HOT
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
Operating instructions
6302 6959 02/2006 GB For the user Operating instructions Logano G215 WS Oil and gas-fired boilers Please read thoroughly before use. Overview Regulations and directives Installation: 90/396/EEC gas appliance
What you can expect from your Solar Hot Water System
Owner s Manual Your Solar Hot Water System Thank you for your investment in the FAFCO Solar Hot Water System. Since 1969 our goal has been to design, test, and produce solar heating systems that save you
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
FUTURE CALL PICTURE CARE PHONE MODEL: FC-1007 USER MANUAL
FUTURE CALL PICTURE CARE PHONE MODEL: FC-1007 USER MANUAL Please follow instructions for repairing if any otherwise do not alter or repair any parts of device except specified. IMPORTANT SAFETY INSTRUCTIONS
INSTALLATION INSTRUCTIONS & OWNERS GUIDE
318442-10 Mar 2013 INSTALLATION INSTRUCTIONS & OWNERS GUIDE RHEEM LOW PRESSURE VITREOUS ENAMEL ELECTRIC HOT WATER HEATERS Congratulations for choosing a Rheem Water Heater It is important that you take
Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual
Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2.0 May 2009 Hyco SpeedFLOW UnVENTED WATER HEATER Models SF10K (10 Litres) and SF15K (15 Litres) 1. Introduction
Hi-Spec. sustainable solutions under one roof HEATING HOT WATER VENTILATION. Warm Air Heaters. with System E-T & Basic Control USERS INSTRUCTIONS
sustainable solutions under one roof HEATING HOT WATER VENTILATION Hi-Spec Warm Air Heaters Publication No. ZZ 0782-11 June 2012 with System E-T & Basic Control USERS INSTRUCTIONS J25 - G.C. No. 42-416-99
Vaillant s plain English guide to. simple, concise and precise
Vaillant s plain English guide to simple, concise and precise Introduction Contents Installing a new boiler 05 Servicing and repairing 13 What s a diverter valve? Why do you need a TRV? And happens when
Due to continual improvement in design or otherwise, the product you purchase may differ slightly from the illustrations in this book.
Kambrook 461 Plummer Street, Port Melbourne 3207, Australia Customer Service Line (free call) 1800 800 634 Customer Service Fax 1800 621 337 Kambrook New Zealand, Private Bag 94411, Greenmount, Auckland,
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Important Safeguards
Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the
Wireless Phone Jack System
926 Manual V2.0(1J9643) 6/10/99 1:39 PM Page 1 RC926 Wireless Phone Jack System (Digital Satellite System # D916) The Wireless Phone Jack System works with most telephone line devices, such as: Answering
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Condensing Water Heater Operation Manual Model NPE-180A/ 210A/ 240A NPE-180S/ 210S/ 240S * Lead Free Keep this manual near this water heater for future reference whenever maintenance or service is required.
Apricus Solar Collector Owner s Manual
Apricus Solar Collector Owner s Manual Australia (Edition 1.1 - March 09) Thank you for purchasing an Apricus solar water heating system. We sincerely hope that your enjoy your solar powered showers, sound
WTSL-SN-1 Alarm Control Unit with Wi-Safe 2 Installation and User Guide
WTSL-SN-1 Alarm Control Unit with Wi-Safe 2 Installation and User Guide "sona control unit install" For use with Wi-Safe 2 Smoke, Heat and Carbon Monoxide Alarms 1 PLEASE READ THIS GUIDE IN FULL BEFORE
Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance
Bench Autoclave Standard Operating Procedure For Installation, Use and Maintenance 1. Introduction This SOP is intended for use with the following model, in a laboratory context: Type: Nuve Bench Top Steam
SERVICE INSTRUCTIONS
SERVICE INSTRUCTIONS 18, 20,24, 26L Integrity Electronic Gas Continuous Flow Water Heater TM031 Reevvi issi ion:: B Publissheed:: Feebrruaarryy 0088 871018 871020 871024 871024-B 871024-C 871026 871026-B
PROFESSIONAL SILK CERAMIC HAIR DRYER USE & CARE MANUAL PLEASE READ PRIOR TO USE 2400 WATTS SILK CERAMIC GRILLE 5 YEAR WARRANTY AC9096AU
PROFESSIONAL USE & CARE MANUAL PLEASE READ PRIOR TO USE SILK CERAMIC HAIR DRYER 2400 WATTS SILK CERAMIC GRILLE 5 YEAR WARRANTY AC9096AU IMPORTANT SAFEGUARDS Warning: When the hair dryer is used in a bathroom,
User Guide and Important Warranty Information. Heatmax Combi HE Range. Condensing Combination Boiler
You can rely on User Guide and Important Warranty Information Heatmax Combi HE Range Condensing Combination Boiler Please keep these instructions in a safe place. If you move house, please hand them over
Duo-tec Combi HE A Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler
User s Operating Instructions & Important Warranty Information Duo-tec Combi HE A Range Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions in a safe place. If you move
Getting the best from your urn
444448538 Standard 444448539 Deluxe Getting the best from your urn Remove any plastic film from the urn before use. Any water in the urn is due to testing and is normal. The urn must be used on a flat
Installation/Operating Instructions. MODELS Bosch 17e Bosch 21e Bosch 25e Bosch 26e INSTALLATION MANUAL
MODELS Bosch 17e Bosch 21e Bosch 25e Bosch 26e (YS1770RA series, YS2170RA series, YS2670RABZ, YS2670RA series) INSTALLATION MANUAL This appliance must be installed in accordance with the manufacturer s
Direct Vent Tankless Water Heater. Operation and Installation Manual
Direct Vent Tankless Water Heater Operation and Installation Manual R50LSi... REU-VA2019FFUD R75LSi... REU-VA2528FFUD(A) R94LSi... REU-VA2535FFUD R98LSi... REU-VA3237FFU R98LSi-ASME... REU-VA3237FFU-ASME
TABLE OF CONTENTS 2 CONGRATULATIONS 3 THE BOSCH STORY 3 PRODUCT OVERVIEW 3 PRODUCT DIAGRAM 4 OPERATING INSTRUCTIONS 5 TROUBLE SHOOTING 6
1 TABLE OF CONTENTS 2 CONGRATULATIONS 3 THE BOSCH STORY 3 PRODUCT OVERVIEW 3 PRODUCT DIAGRAM 4 OPERATING INSTRUCTIONS 5 TROUBLE SHOOTING 6 CARE & SERVICING OF THE UNI T 6 10 BASIC STEPS FOR INSTALLATION
Please read and keep these instructions. Run water through your machine before first use
47070 Rev 1 24/3/05 2:23 PM Page 1 12 cup filter coffee maker Please read and keep these instructions getting the best from your new coffee maker Safety first Caution must be used when handling hot water,
Owner s Manual. & Installation guide. Installation Details Owner s Information Warranty. 4 Star Gas Hot Water Heater
Owner s Manual & Installation guide Models 135THM4N 135THM4P 170THM4N 170THM4P Installation Details Owner s Information Warranty For advice, repairs and service, call: 1800 080 055 Carefully remove all
Owner s Manual. Installation Details Owner s Information. 80L to 400L Electric Storage Water Heaters
Models: RIN80E24 RIN80E36 RIN125E24 RIN125E36 RIN160E24 RIN160E36 RIN250E36 RIN315E36 RIN400E36 Installation Details Owner s Information For advice, repairs and service, call: 1300 555 545 Carefully remove
SF15K SF05KSS, SF10KSS
Product Instruction Manual Speedflow SF05K, SF10K & SF15K SF05KSS, SF10KSS & SF15KSS Undersink unvented water heater V15.6/6 Version 3.2 Jan 2015 Thank you for purchasing a Hyco Speedflow unvented water
Operating instructions
Operating instructions Gas condensing boilers MGK-130 MGK-170 MGK-210 MGK-250 MGK-300 Wolf GmbH Postfach 1380 D-84048 Mainburg Tel. +49 8751/74-0 Fax +49 8751/741600 Internet: www.wolf-heiztechnik.de Document
USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat
Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage
Rousseau 10. User Guide
Rousseau 10 User Guide Base station overview ➀ LED signals White, permanent light: - Base station ready, you can register a handset Slow flashing white light: - Paging call in progress - Active call (you
Tankless Water Heater
Tankless Water Heater USER S INFORMATION MANUAL Models WGRTNG199 / WGRTLP199 WGRTCNG199 / WGRTCLP199 NOTICE: Westinghouse reserves the right to make product changes or updates without notice and will not
Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.
EHYHBH05AA EHYHBH08AA EHYHBX08AA English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview: Operation...
Owner s Guide and Installation Instructions
Owner s Guide and Installation Instructions Outdoor Domestic Mains Pressure Gas Storage Water Heater G270SS, G340SS & G390SS Series This water heater must be installed and serviced by a qualified person.
Artisan Thermostatic bath shower mixer. Fitting Instructions & Contents List
Artisan Thermostatic bath shower mixer Fitting Instructions & Contents List Please keep these instructions for future reference and request of replacement parts Contents Page 1. Introduction 03 2. Specification
To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)
OPERATION MANUAL Split System Ducted Air Conditioner To suit Daikin FDY "F" Series and FD "F" Series AIR CONDITIONER A hr o C (and other models incorporating BRC1B62/52 Remote Controller) Dear Owner, Thank
Look after your boiler so it can look after you
Look after your boiler so it can look after you This guide covers the steps you can take to ensure that your Vokèra boiler continues to operate efficiently and safely. No-one knows your boiler better than
Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)
Use & Care Manual With Installation Instructions for the Installer Electric Tankless Water Heaters The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations
TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. 2 Inch PowerVent LED Indicator Explanations & Troubleshooting Table
New Robertshaw control valve was introduced in May 2008 as a replacement part. See last page for troubleshooting this replacement part. All voltage inputs are 120V. All electrical connectors are Molex
Electric Water Heater
Electric Water Heater Operation and Installation Manual (LIMITED WARRANTY AND TANK REPLACEMENT POLICY) The following information should be noted at time of installation and retained for future reference.
TANKLESS WATER HEATER INSTALLATION DIAGRAMS
TANKLESS WATER HEATER INSTALLATION DIAGRAMS Installation Diagrams Tankless Installation / Optional Return Small 10-15 Gallon Point-of-Use Water Single and Optional Return : One single, small capacity water
Whole House Water Treatment System. Installation, Operation and Maintenance Manual. Multi-Pure Model TO15000
Multi-Pure Whole House Water Treatment System Installation, Operation and Maintenance Manual Multi-Pure Model TO15000 Warning Please read manual carefully before proceeding with installation. It is recommended
Dehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
CM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?
WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?...an explanation for householders A programmable room thermostat is both a programmer and a room thermostat. A programmer allows you to set On and Off time periods
Service Manual REU - 16 FUA - E. Infinity 16 i. Continuous Flow Water Heater. Important.
Service Manual REU - 16 FUA - E Infinity 16 i Continuous Flow Water Heater Important. Read these instructions carefully before attempting service of this appliance. All work must be carried out by competent
Safe Method: Gas Safety in Catering Establishments
Safe Method: Gas Safety in Catering Establishments Safety Point Why? What do you do? Gas equipment and services must only be installed, maintained and repaired by a Gas Safe registered installer. Check
User Guide and Important Warranty Information. Suprima 30L - 100L. Wall Mounted Fan Assisted Balanced Flue Gas Boiler
User Guide and Important Warranty Information Suprima 30L - 100L Wall Mounted Fan Assisted Balanced Flue Gas Boiler These instructions are for use with boilers whose serial numbers end C (or higher) only.
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
INSTANT HOT WATER RECIRCULATING SYSTEM
INSTANT HOT WATER RECIRCULATING SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS Save manual for future reference MODEL 500800 Warning Please read carefully before proceeding with installation. Your failure
HEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
Morco House Riverview Road Beverley HU17 0LD
Morco House Riverview Road Beverley HU17 0LD Morco Products Ltd Tel: 01482 325456 Fax: 01482 212869 Email [email protected] Web www.morcoproducts.co.uk Combi Boilers - Poor Hot Water Delivery Combi
User Manual THR840DUK Digital Thermostat
User Manual THR840DUK Digital Thermostat 50051982-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-24). If you are not experienced in wiring electrical
Gas Instantaneous Water Heater
6 720 607 884 (2009/05) GB Installation Manual and Operating Instructions Gas Instantaneous Water Heater WR8..P... WR11..P... With piezo ignition and double safety system consisting of flue gas monitor
Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3
EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3 English Table of Contents Table of Contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview:
INSTANTANEOUS GAS FIRED
INSTANTANEOUS GAS FIRED Celt Star C Britony II T Britony FlexiFlue Hot water on demand Instantaneous gas fired water heaters Instant hot water from the world leader Back in 1925 Chaffoteaux & Maury invented
Heat Pump Water Heater IOM Manual
Heat Pump Water Heater IOM Manual Installation Operation & Maintenance This manual is intended as an aid to qualified service personnel for proper installation, operation and maintenance of the heat pump
Instruction manual for Firstline FCS12000CH
Instruction manual for Firstline FCS12000CH Contents Introduction... 2 Safety Awareness... 3 Safety Awareness... 4 Name of Parts... 5 Name of Parts... 6 Remote Controller Preparation... 7 Operation of
Home comfort: water heating
Home comfort: water heating Water heating usage Hot water. It s one of those luxuries we give little thought to until we run out. This information is provided to help you get the most value and comfort
evohome Wireless Radiator Zoning Kit Installation & User Guide
evohome Wireless Radiator Zoning Kit Installation & User Guide Getting the most from your evohome system Installation & User Guide 1 Getting the most from your evohome system Thanks for choosing an evohome
Owners Guide and Installation Instructions.
ELECTRIC Owners Guide and Installation Instructions. VULCAN Loads of hot water, oads of savings This water heater must be installed and serviced by an authorised person. Please leave this guide with householder.
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer