Security System Installation Guide
|
|
|
- Julian Ray
- 9 years ago
- Views:
Transcription
1 Security System Installation Guide
2 Cooper Security Ltd. 009 Every effort has been made to ensure that the contents of this book are correct. However, neither the authors nor Cooper Security Limited accept any liability for loss or damage caused or alleged to be caused directly or indirectly by this book. The contents of this book are subject to change without notice. Printed and published in the U.K. This manual applies to the i-on40 control unit with version.00 software. For Your Safety This book contains several passages alerting you to potential problems or hazards. Each of these are marked by the words Note, Caution or WRNING.: Note: Describes conditions that may affect the proper functioning of the equipment (but will not damage the equipment). Caution: Describes actions that will physically damage the equipment and prevent its proper function. WRNING: Describes actions that are hazardous to health, or cause injury or death. Please pay particular attention to these marked passages. Other Publications for the i-on40: User Guide Instructions for setting and unsetting an alarm system based on the i-on40. dministrator s Guide Detailed notes for the system administrator of an alarm system based on the i-on40. The following guides are available from the Cooper Security website: Programming Reference Guide detailed description of the Installer s programming options available on the i-on40. Web Server Setup Guide Instructions on how to configure a Windows PC or laptop to use the i-on40 s built-in web server for installation programming. i-on Flashloader Installation and User Guide This booklet shows you how to install i-on Flashloader on your PC and use it to update the software on your i-on40 control unit. Page ii
3 CONTENTS. Introduction... Communications... Level Setting or Partitioned System.... efore You egin... Preparation... Siting the Unit... Guided Tour... Opening the End Station Case... End Station PC... Keypad Controls and Displays... Opening the Keypad... Power vailability Installation... 5 Step. Fit the Control Unit ox... 5 Caution: Static Electricity... 5 Fitting... 5 Step. Fit and Connect the Keypad(s)... 5 Siting the Keypad(s)... 5 Fitting... 5 Connecting Keypads to End Station... 6 Keypad ddressing... 7 acklight Control... 7 Tone Volume... 7 Step. Connect End Station to Mains... 7 Mains Cabling... 8 Mains Connection... 8 Step 4. Connect Wired Zones... 8 Four Wire Closed Circuit Connections... 8 Fully Supervised Loop Connections... 8 Step 5. Connect Wired Peripherals... 9 Remote Loudspeaker (Optional)... 9 Wired External Sounders (Optional)... 9 Wired Outputs (Optional)... 9 Step 6. Fit a Plug-y Communicator... 0 Step 7. Fit and Connect attery... 0 Programming efore Installation... Step 8. Initial Power-Up... Step 9. Commission the System Programming... Entering the Installer Menu... Leaving the Installer Menu... Important! Saving Changes... Restoring the ccess Codes ( st stage Reset)... Restoring Factory Defaults... 4 Installer Menu... 5 Zone Types & ttributes... 6 Output Types... 8 Exit Modes Maintenance Technical Specification... General... Capacities... Security... Radio... Power Supply... Electromagnetic Compatibility... Outputs... Fuses... Electrical Safety... Compliance Statements... Compatible Equipment... 4 Page iii
4 This page is intentionally blank. Page iv
5 . Introduction The i-on40 is the control unit for a hybrid wired/wirefree alarm system intended for domestic and light commercial use. The control unit comprises an end station and up to four separate wired keypads. The end station has an S plastic case which contains the radio transceiver, power supply and backup battery. The keypad(s) connect to the end station by standard alarm cable. The keypads allow end users to set and unset the system, and the installer to configure the control unit. The keypads also contain integral proximity tag readers, allowing end users to control the system without having to remember access codes. range of wireless peripherals is available for operation with the control unit. These include a door contact/universal transmitter, a passive infra red detector, smoke detector, external siren, 4 button remote control, and remote radio keypad. The control unit supports up to 6 wired alarm zones, 4 wirefree alarm zones, up to 6 hardwired outputs, 50 four-button remote controls, 50 two-button radio panic alarms, and 50 users. See page. Communications The i-on40 provides sockets for an add-on communication module. The available modules are: i-sd0 speech dialler and public switched telephone network (PSTN) module that allows the control unit to send recorded speech messages and report alarm information using standard protocols such as Fast Format, SI and Contact ID. This module also allows remote maintenance. i-dig0 switched telephone network (PSTN) module that allows the control unit to report alarm information using standard protocols such as Fast Format, SI and Contact ID. This module also allows remote maintenance. i-gsm0 GSM module that allows alarm reporting, speech messaging and SMS text messaging over the mobile phone network n Ethernet module that allows alarm reporting and remote maintenance over the internet GPRS module that allows internet protocol access over the mobile phone network. Level Setting or Partitioned System The i-on40 offers two basic ways of behaving as an alarm system: Part Setting. In a Part Setting system the i-on40 can set in one of four ways: either Full set or three varieties of Part Set. In Full set the control unit pays attention to all detectors. In each of the three Part Sets the control unit ignores detectors that do not have the appropriate Part Set attribute (see page 7 ). Partitioned System. In a Partitioned system the i-on40 provides the equivalent of four, smaller, independent alarm systems. Each system is a Partition of the i-on40. You can allocate any zone to each Partition. Each zone can also belong to more than one Partition. Each Partition can have a Full Set level and one Part Set Level. During installation the installer can allocate keypads, sounders or outputs to any of the partitions. This manual shows the simple procedure required to install the control unit and its keypad. When you have completed the physical installation please consult the Programming section for details of configuring the system to meet your exact requirements. For a detailed description of the Installer s programming menu please read i-on40 Programming Reference Guide available from Page
6 . efore You egin Preparation efore installation you should carry out a survey of the site. You need to know how many and what kind of detectors will be transmitting to the control unit. You also need to assess where the control unit must be placed in order to receive radio signals from the detectors successfully. To do this you should conduct signal strength tests. Cooper Security produce the Scantronic 790r hand held signal strength meter for this purpose. lternatively, you can power the control unit from a battery and use its built-in testing facility to measure the signal strength from a detector that you temporarily place at each planned location. Siting the Unit Do site the unit: Upright (battery at the bottom). Within a protected zone. s high as possible. However, do make sure that the unit is on a similar level to the other transmitters or receivers. Do NOT site the unit: In the entry or exit zones, or outside the area covered by the alarm system. Close to or on large metal structures. Closer than one metre to mains wiring, metal water or gas pipes, or other metal surfaces. Lower than two metres from the floor (ideally). Inside metal enclosures. Next to electronic equipment, particularly computers, photocopiers or other radio equipment, CT 5 data lines or industrial mains equipment. Note: Some window glasses, especially those sold as insulating or energy conserving may be coated with thin metal or conducting films. These glasses are particularly poor at transmitting radio waves. If fitting two or more keypads make sure that you do not place the keypads within one metre to each other. (The proximity tag readers in each keypad will interfere with each other.) Remember not to place keypads on opposite sides of the same wall. Guided Tour Opening the End Station Case To gain access to the interior of the end station undo the two screws at the top of the case. Pull the top of the lid down, and then lift the lid out of the retaining lugs at the bottom of the case. Figure Opening the end station. WRNING: When connected to the mains with power applied mains voltages are present on the shrouded heads of the terminal screws of the mains connector ( 8 in figure ) Figure Control Unit. Central fixing keyhole.. erials.. Fixing holes. 4. Connector pins for Lid Tamper. 0 9 Page
7 5. Printed circuit board (PC). 6. Cable entry holes for detector and keypad wiring. 7. Transformer. 8. Mains connector block. 9. Cable entry hole for mains. 0. ack Tamper switch (if fitted). End Station PC 0. Siren test output (not used in UK). Keypad Controls and Displays 4 5 C D 4 ghi 7 pqrs abc 5 jkl def 6 mno 8 tuv 9 wxyz Figure End Station Printed Circuit oard. erials (CUTION: do not bend).. Tamper connector.. US socket (Mini ). 4. Ethernet link activity LEDs. 5. 0VC input (from transformer). 6. attery connector. 7. Kick Start pins. 8. Ethernet socket. 9. Heartbeat LED 0. RS485 terminator.. Code reset pins.. Plug by connector pins -6.. Plug by connector pins to. 4. Comms activity LED. 5. Sockets for plug on module Figure 5 Controls and Displays. LCD display ( x 0 characters).. Programming keys.. Navigation keys 4. lert LEDs 5. Setting and unsetting keys. 6. Panic larm (P) keys. 7. Number/text keys. 8. Set/Unset LEDs. Opening the Keypad To open the keypad first gently prise off the trim on the front and remove the two screws. Next, carefully lever the front of the keypad (containing the pcb and display) away from the keypad rear housing Figure 4 End Station Main Connectors. ux power.. Outputs (relay).. ux power. 4. Keypad bus. 5. Wired zone connectors. 6. Ethernet connector. 7. Loudspeaker. 8. Wired siren tamper return. 9. Outputs (transistorised). Figure 6 Opening the Keypad Page
8 4 Figure 7 Keypad Rear Housing. Central keyhole.. Rear tamper shroud.. Cable entry. 4. Fixing holes Power vailability i-on40 efore connecting any external devices to the control unit, you must make sure that the control unit can provide sufficient current to power the system during a mains failure for the time required to meet Grade PD666 or EN50-. The amount of current available from the control unit depends on the battery fitted. The current taken by the control unit pcb and keypads is given in Technical Specifications on page. For example: in an alarm system with an i- on40 control unit, two i-kp0 keypads, and 5 wired PIRs the system takes the following total current: Device Current Control unit PC 0m 5 x PIRs at 0m each 00m x i-kp0 at 0m each 60m (backlights off) Total 490m fully charged 7h battery can provide 580m for hours. In this example a 7h battery should exceed the Grade requirements. ET V 0V 4a 4b 4 CD-ON CKLIGHT ON RIGHT Figure 8 Keypad PC. Sounder.. Sounder volume control.. Tamper switch. 4. Jumpers for addressing and LED function: 4a ddressing 4b LED functions 5. RS485 termination jumper 6. Connector for control unit (note that the ET terminals are inactive). Page 4
9 . Installation Exposure to Radio Frequency Radiation The radiated output power of this device is below those levels considered safe by European exposure limits. Nevertheless, when fitting the product place it in such a manner as to minimise the potential for human contact during normal operation. To minimise exposure, users should be more than 00 mm from the device during normal operation Step. Fit the Control Unit ox Caution: Static Electricity Like many other electronic products, the control unit contains components that are sensitive to static electricity. Try not handle the PC directly. If you must handle the PC, take the standard precautions against damage by static electricity. Fitting the back of the end station on a wall. Use No0/M5 countersunk screws at least 6mm long. Figure 9 shows the fixing holes and cable entries. Protect the unit from dust and drilling debris when drilling the fixing holes. Step. Fit and Connect the Keypad(s) Siting the Keypad(s) Do site the keypad(s): Within the area protected by the alarm system. t a convenient height and location for the user. Out of sight of potential intruders. Do NOT site the keypad(s): Next to electronic equipment, particularly computers, photocopiers or other radio equipment, CT 5 data lines or industrial mains equipment. Where the cable run from the end station will be longer than 00m (see Cable Configuration and Length). Note: Do not site two or more keypads closer than one metre together, otherwise their prox readers will interfere and be unable to read tags. Fitting Use M4 5mm countersunk screws in at least three fixing holes when mounting the back of the keypad on the wall. Figure 9 Fixing Holes and Cable Entries. Fixing holes.. Cable entries. Cooper Security recommend that you use at least four fixing holes when mounting Figure 0 Screw Keypad ack ox to Wall Page 5
10 abc def 4 ghi 5 jkl 6 mno 7 pqrs 8 tuv 9 wxyz abc def 4 ghi 5 jkl 6 mno 7 pqrs 8 tuv 9 wxyz abc def 4 ghi 5 jkl 6 mno 7 pqrs 8 tuv 9 wxyz abc def 4 ghi 5 jkl 6 mno 7 pqrs 8 tuv 9 wxyz abc def 4 ghi 5 jkl 6 mno 7 pqrs 8 tuv 9 wxyz abc def 4 ghi 5 jkl 6 mno 7 pqrs 8 tuv 9 wxyz abc def 4 ghi 5 jkl 6 mno 7 pqrs 8 tuv 9 wxyz abc def 4 ghi 5 jkl 6 mno 7 pqrs 8 tuv 9 wxyz Connecting Keypads to End Station Star i-on40 Daisy Chain Cable Type In general, the control unit requires standard 7/0. un-screened four core alarm cable for wiring to keypads. For maximum performance in harsh environments use twisted pair cable with a characteristic impedance of 00-0ohms eg: CT5 or cable designed for RS485. Use one pair for data bus &. Use the other pair for V & 0V. Screened cable may prove necessary if the installation site has equipment that produces high levels of R.F. (Radio Frequencies), for example welding equipment. If screened cable is required, you should keep to the following guidelines:. void earth loops by connecting the screen on the cable to mains earth at the end station but not at the keypad.. The continuity of the cable screen is most important and screens MUST be continuous along the full length of the cable.. If the cable enters any metal enclosure, ensure the screen is isolated from the case. 00m terminate terminate 50m Figure Keypad Wiring Configurations For star configurations the cable length from control unit to the most distant keypad should not exceed 00m. For a daisy chain configuration the total cable length should not exceed,000m, Connection Figure shows the wiring connections at the keypad and control unit. Cable Segregation Segregate the keypad cabling from any other wiring, such as mains supply cables, telephone cables, computer network cables and R.F. cables. Use cable ties to keep cables separated. Keep the keypad cable clear of cables supplying sounders or extension loudspeakers. ET V 0V Cable Configuration and Length You can connect up to four wired keypads to the end station. You may connect the keypads either in daisy chain (serially), or in star (parallel) configuration at the end station connector. Figure Keypad Connection Temination The i-on40 data bus uses the RS485 interface. ecause of this the ends of the line in some configurations may be terminated to improve performance in electrically noisy environments or where there are long cable runs. oth control panel and keypads have a termination link on their PCs (see 0 in Fig for the Page 6
11 4 ghi 7 pqrs 4 ghi 7 pqrs abc 5 jkl def 6 mno 8 tuv 9 wxyz abc 5 jkl def 6 mno 8 tuv 9 wxyz 4 ghi 4 ghi 7 pqrs 7 pqrs abc 5 jkl abc 5 jkl def def 6 mno 8 tuv 9 wxyz 6 mno 8 tuv 9 wxyz 4 ghi 7 pqrs abc 5 jkl def 6 mno 8 tuv 9 wxyz 4 ghi 7 pqrs 4 ghi 7 pqrs abc 5 jkl def 6 mno 8 tuv 9 wxyz 4 ghi 7 pqrs abc 5 jkl def 6 mno 8 tuv 9 wxyz 4 ghi 7 pqrs abc 5 jkl def 6 mno 8 tuv 9 wxyz abc 5 jkl def 6 mno 8 tuv 9 wxyz 4 ghi 7 pqrs abc 5 jkl 4 ghi 7 pqrs def 6 mno 8 tuv 9 wxyz abc 5 jkl def 6 mno 8 tuv 9 wxyz i-on40 control unit and 5 in Fig 8 for the keypad). Fitting a jumper to the pins adds a termination to the cable. In a daisy chain configuration terminate each end of the chain (see Fig ). In a star configuration: If there are only two keypads then this is the same as a daisy chain configuration. If required terminate at each keypad. If there are more than two keypads ND two cables are long while the remaining keypad cables are short (less than 0m) then it is possible to terminate at the two keypads with long cables. If there are more than two keypads UT each keypad cable is more than 0m then DO NOT terminate. Keypad ddressing Each keypad connected to an end station must have a unique address. See Figure 8 on page 4 for the position of the addressing jumpers. CD-ON The set/unset LEDs shows the setting status of the system. (Full set is left hand led.) L ON RIGHT The key backlights are disabled. They will glow briefly for five seconds when a user presses a key. L ON RIGHT The key backlights glow all the time at normal intensity. L ON RIGHT Figure Keypad ddressing Jumpers acklight Control You can control the appearance of the keypad backlights and set/unset LEDs by fitting links over the appropriate jumpers on the keypad pcb (see Figure 8 on page 4 for the position of the jumpers). The jumpers have the following functions: CD-ON The set/unset LEDs are disabled. 4 The keypad backlights glow all the time, extra bright. Tone Volume To alter the volume of non-alarm tones from the keypad adjust the keypad sounder volume control ( in Fig 8): Louder Note: This control changes the volume of non-alarm tones (for example Exit/Entry tone). The volume of alarm tones is fixed. Softer Step. Connect End Station to Mains WRNING: ENSURE THT THE MIN SUPPLY IS DISCONNECTED ND ISOLTED EFORE MKING NY MINS CONNECTIONS. ll mains electrical connections must be carried out by a qualified electrician and must comply with the current local regulations (e.g. IEE). Page 7
12 Mains Cabling Make sure that the mains supply cable does not run vertically behind the aerials within the end station case. If you wish run mains cable through the side of the case, make sure that they are horizontal for the last metre before entering the case. Step 4. Connect Wired Zones Four Wire Closed Circuit Connections >m >m Tamper Zone Tamper Zone larm Zone larm Zone Figure 4 Mains Cabling Clearance Note: To avoid mains interference, the mains cable must enter the control unit through its own cable entry hole ( 9 in Fig ) and must not be mixed with other cables. Mains Connection Figure 5 shows the mains connection. Connect to a suitable supply using a double pole disconnect device in accordance with EN Caution: Do not apply power at this point. nchor the mains cable with a strain-relief tie. There is a eye located near the mains cable entry hole for this purpose. N L 0V ~50Hz 00m T50m 50V Figure 5 Mains Connection Figure 6 Closed Circuit Loop Zone Wiring Fully Supervised Loop Connections Figure 7 shows the wiring connections for Fully Supervised Loop zones. Note that the resistance values shown are examples. The allowed values for larm Contact/End of Line are: 4k7/k. k0/k0, k/k, or 4k7/4k7. Use the same pair of values for LL FSL wired zone circuits. When programming select the correspondings value in Installer Menu - System Options - Wired Zone Type If you wish to connect two or more detectors to a FSL zone, the diagram at the bottom of Figure 7 shows the connections required. Figure 8 shows an example of wiring double doors with two door contacts to one FSL zone. Each door contact is a reed switch, connected between the outer terminals. The inner (shaded) terminal is not connected, and provides a spare terminal. Page 8
13 Step 5. Connect Wired Peripherals 00 Ohms V + 0V 4K7 Tamper In Tamper Out Strobe +ve Zone larm contacts Tamper contacts K EOL Strobe -ve Trigger -ve Zone 4K7 larm contacts Tamper contacts K EOL 4K7 Zone larm contacts Tamper contacts larm contacts Tamper contacts K EOL +LS -LS To zone contacts Max 0 devices per circuit (not recommended) Figure 7 Fully Supervised Loop Zone Wiring lue Yellow 4K7 Spare Red lack Figure 8 Example: Wiring Two Door Contacts to One FSL Zone. K EOL Figure 9 Connecting Wired Peripherals The end station pcb provides four connectors for wired outputs. Outputs and are voltage free relay outputs. Outputs and 4 are driven by transistors, and are capable of sinking a maximum 500m when active. y default outputs and 4 are 0V when active, +V when inactive. If you wish to reverse the polarity of these two outputs use Installer Menu - Outputs - Wired Outputs Output (4) - Polarity. Remote Loudspeaker (Optional) If you wish to add a wired Loudspeaker unit, then connect it as shown in Figure 9. Wired External Sounders (Optional) Wired external sounders differ in their methods of connection. Figure 9 shows an example of a general method of using the outputs to connect a wired sounder. Note: If you do not wish to connect a wired external sounder then make sure you link TR to 0V. This prevents the control unit reporting ell Tamper unnecessarily. Wired Outputs (Optional) Figure 9 shows an example of using the wired outputs to drive an indicator LED. Page 9
14 Step 6. Fit a Plug-y Communicator The control unit can be connected to a separate communicator or speech dialler (for example, the Scantronic 8400, 8440, 660 or RedCare STU). Figure 0 shows the connections provided by the communications wiring harness. Com Connector Cable, Part number 4850 Com Connector Cable, Part number O/P0 (rown) O/P (Orange) O/P (Yellow) O/P (Green) Figure 0 Plug-y Communicator Wiring Note: Comms O/P4 will be active when the system is unset. This is normal. To fit a communicator, follow the instructions below. Caution: Follow the instructions in the order shown, or you may damage the control unit and/or communicator.. Disconnect mains and battery power from the control unit and remove the case lid, if the system has already been installed.. Make any necessary connections from the communicator to the communication wiring harness. The default is a V positive voltage when the output is inactive. Refer to the next section if you are using a dual-path communicator.. Plug the Communication Wiring Harness onto the communications connector on the main PC. If the system has already been installed: 4. Re-connect the battery. 5. Fit the case lid. 6. pply mains power. 7. Test communicator operation. Line Monitoring for a Dual-Path Communicator If a standalone dual-path (landline and mobile) communication device, such as a RedCRE STU, is connected to the plug-by connector, you need to do the following to obtain correct line fault reporting (this is not necessary if you are using a plug-on module):. Wire a panel output programmed as type "TS Test" to the TS Test input of the communicator.. Wire the Line Fault output of the communicator to the Line Fault input of the plug-by connector. The communicator must provide +Vdc to indicate a line fault (for example, if the Line Fault output at the communicator uses a relay, connect the common terminal of the relay to +Vdc and the normally-open terminal to the Line Fault input of the plug-by connector). The panel will generate an "TE L.F. Single" alert if only one of the networks is not available, or "TE L.F. ll" if both networks are not available. Step 7. Fit and Connect attery Fit a 7h Lead cid battery into the battery compartment in the bottom of the control unit, see Figure. Make sure that you secure the battery to the case with the strap provided. Connect the battery leads, red to the positive, black to the negative terminals of the battery. Figure Fitting the attery Page 0
15 Note: Connecting the battery without mains power will not start the system. (See Programming Control Unit efore Installation below if you wish to start the system on battery power.) Programming efore Installation If you prefer, you can make the control unit learn the detectors and other peripherals before installing the system in its final location. You will need to temporarily connect a keypad to the end station. It is possible to operate the end station from battery power (or a Vdc supply) without connecting the unit to a mains supply. However, in order to start the end station processor running you must briefly short the Kick Start pins together after connecting the battery. When programming the system while it is running on battery only, remember to leave the Installer Menu before removing power. If you do not do so all your changes will be lost, see Important! Saving Changes on page If you wish to program the control unit from a laptop or PC you can do this by connecting the control unit to your PC via Ethernet. You will need a CT 5 patch cable and a laptop or PC with a standard web browser. See the separate publication i- on40 Web Server Set Up Guide for instructions on how to set up your PC/laptop and the control unit. Step 8. Initial Power-Up WRNING: During initial power-up all the keypad sounders and any internal loudspeaker will give an alarm tone. If you are working at the top of a ladder make sure that the sudden noise does not startle you and cause a fall.. pply mains power to the control unit. The keypads and internal sounder give an alarm tone. The heartbeat LED (see fig ) starts flashing. The display initially shows: Language? English. Press u or n to show other languages on the bottom line of the display. for example: Language? Nederlands. Press Y to select the language you want. From this point on, the display operates in the selected language. If you want to change the language later use Installer Menu - System Options - Language. The display shows: COUNTRY DEFULTS *UK 4. Press u or n to show other countries, for example: COUNTRY DEFULTS Italy 5. Press Y to select the country you want. The display shows: : Partition mode : Part set mode 6. Press or to select either a partitioned system or a Part Setting system. The display shows: Load Profile? 7. Either: Press Y to load the Profile. Or: Press X to start with a blank system The end station loads your choice of profile, and then shows: WIRED ZONE TYPE *-wire FSL k/4k7 8. Press u or n to show the range of wiring types available, for example: WIRED ZONE TYPE 4-wire CC 9. Press Y to select the wiring type you intend to use for the wired zones The display shows: I-ON40 00:00 0/0/009 Note that the alert LEDs round the navigation glow red. This is because the end station lid is off and the tamper is active. 0. Remove both battery and mains power. Re-apply battery power followed by mains. The sounders stop. t this point you can carry on to commission the system. See the next page. Note: Setting the time and date is an administrative user function. See i-on40 dministrator s Guide for instructions. Page
16 Step 9. Commission the System fter installing the control unit you should commission the alarm system as follows:. Use the Installer Menu (see Chapter 4) to teach the control unit the identity of its radio detectors and any other peripherals. See the installation instructions supplied with each detector or peripheral.. Install detectors and peripherals at their selected locations.. Use the Installer Menu Test (see Chapter 5) option to: a) carry out a walk test of the detectors. b) test the operation of any other peripherals. 4. Program the system to suit user requirements. See the i-on40 Programming Reference for a detailed description of the Installer Menu. 5. ssemble and close the end station: a) Hook the lid of the control unit into the bottom of the back box. b) Close the lid and then tighten the two fixing screws. Figure Replacing the end station lid. 6. Leave the Installer Menu. The red LEDs should go out, and the rim of the navigation keys glow green. The system is now ready to hand over to the user. 7. Instruct the user on how to operate the system. See the i-on40 User Guide and the i-on40 dministrator s Guide. If necessary, show them how to set the time and date on the system. Page
17 4. Programming This section is summary of the Installer Menu on the i-on40. Please see the i-on40 Programming Reference for a more detailed description. Entering the Installer Menu. Make sure the system is unset and showing the standby screen (time and date).. Key in the Installer access code. When delivered from the factory the default Installer access code is The default user code is 4. s you start to key in the code the display shows: Enter ccess Code: (* ) When you key in the last digit of the Installer access code the display shows: User Code Required ( ) Note: You will see this screen the first time you enter the Installer menu on a new control unit, or if you have restored Factory Defaults.. Key in the default user code (see Note below). The display shows: Installer Menu Detectors/Devices> 4. Press u or n to display more items from the menu. Each item appears on the bottom line of the display in turn, for example: Installer Menu Outputs > 5. Press > to select that item of the menu. The option you selected now appears on the top line. If there are any suboptions for that selection, then the first of them appears on the bottom line, for example: Outputs Edit Outputs > You can press u or n to display the other sub-options. Note: If you key in an access code incorrectly, the display shows four stars. Key in the code again. If you key in a total of ten incorrect codes then the system locks you out for 90 seconds. Leaving the Installer Menu If you wish to leave the Installer Menu at any time.. Press X until the display shows the words Leave installer mode?. Leave installer mode?. Press Y to leave Installer menu. (Press X if you do not want to leave the menu.) The display shows the time and date. i-on40 :00 0/0/008 The system is ready for use. Note: If you attempt to leave the Installer Menu when a detector tamper is active then the keypad displays a fault message telling you which detector is causing the problem. Press X to return to the Installer Menu. You must either close the detector tamper or delete it from the system before you can leave the Installer Menu. Important! Saving Changes When you make changes to the Installer Menu the control unit holds those changes in temporary memory until you leave the Installer Menu. s you leave the Installer Menu the control unit writes those changes into a permanent store. If you remove all power EFORE you leave the Installer Menu then the control unit will lose your changes. Note that this does not apply if you restore Factory Defaults, that change takes place immediately. Restoring the ccess Codes ( st stage Reset) If the user and/or Installer codes are lost then:. If possible, enter the Installer menu. Note: If you cannot enter Installer Menu then the end station will start a tamper alarm when you open the end station lid.. Remove mains power, then open the case and disconnect the battery. Note: This procedure will not work if the control unit lid tamper remains closed. Page
18 . Identify the Reset Codes pins on the main PC (see Figure ). 4. Short the Reset Codes pins together using a screwdriver or jumper link. (Keep the short on until step 6.) 5. pply mains power. The control unit loads the factory default access codes: User : 4, Installer: fter a short pause the keypad display shows the time and date. The red LEDs glow to show an alert that the panel lid is open. The system may start a tamper alarm. 6. Remove the short from the Reset Codes pins. 7. Reconnect the battery. 8. Close the end station lid (to restore the tamper switch). 9. Key in 4 to silence the sirens (if necessary). Press Y twice (if necessary) to acknowledge any alerts. If the red LEDs around the navigation key still glow then there may be an alert for a missing battery that needs acknowledgement. To force the end station to check the battery: 0. Enter Installer Menu and then leave it again.. Press Y, key in 4, press Y again. The navigation key LEDs should now glow green. Restoring Factory Defaults If you wish to restore all factory default options then:. From the Installer Menu select System Options Restore Defaults Factory Defaults. The display asks for confirmation.. Press Y to load defaults. (Press X to go back to the Installer Menu without changing defaults.) The display asks you to select Partition Mode or Part Set Mode.. Press or to select the desired mode. The display asks you to select the zone wiring type. 4. Press u or n to display the desired wiring type on the bottom line of the display and then press Y to select it. The system loads all defaults except for ccess Codes and the Log (see Note). The display returns to the Installer Menu. Note: The log is protected and cannot be erased by the Installer. Page 4
19 Installer Menu DETECTORS/DEVICES Detectors dd/del Detectors Zone Delete all Edit Zones Zone Name Type Partitions ttributes 6 Wired Keypads Keypad Name Partitions Key... Radio Keypads dd/del Radio Keypad Edit Keypads External Sirens dd/delete Ext. Siren Edit external siren Info Modules Teach Info Module Updates Ready-to-set LED WMs dd/del WM View WM 5 COMMUNICTIONS RC Reporting 5 Call Mode Phone book IP Network 5 ccount Number Report Type Fast Format channels CID/SI Events 4 Restorals 4 urg Comms Rearm CN FF ck time Send tamper as burg 4 Dynamic Test Call Static Test Call Speech Dialler Call Mode Messages Phone ook Triggers Destinations Call cknowledge OUTPUTS Radio outputs dd Outputs Edit Outputs Output Name Type Wired outputs Output...4 Name Type Polarity Partitions* Plug-by outputs Output... Name Type Polarity Partitions* Communications (cont d) SMS 5 Call Mode Messages Phone ook Triggers Line Fail Response IP Network (Own) Web Server GPRS 5 Ethernet 5 Downloading ccount Connection Type Rings to nswer 5 nswer on one ring 5 ccess Mode 5 Phone ook 5 Secure Callback 5 Modem aud Rate 5 SETTING OPTIONS Full Set Name Exit Mode Part Set Name Exit Mode Part Set larm Response Part Set Final Exit Part Set Entry Route Part C, D (See Part Set ) Exit time Entry time Strobe on Set Strobe on Unset PRTITIONS Partition...4 Name Exit Mode Exit Time Entry Time larm Response Part Set Exit Mode Part Set larm Response Part Set Final Exit Part Set Entry Route Strobe on Set Strobe on Unset 6 TEST Sirens & Sounders Wired Keypad Walk Test Zone Resistances Signal Strengths Detectors Radio Keypads External Sirens WMs Remotes 8 Panic larms 8 Outputs Radio Outputs Wired Outputs Plug-by outputs Remotes Panic larms Prox Tags RC Reporting Speech Dialler 5 PSU Current 4 SYSTEM OPTIONS Wired Zone type User ccess P keys active Quick Set Quick Omit User code reqd User reset Zone alarms 7 Zone tampers System tampers DD4 Confirmation Confirmation time fter Entry Entry Keypad Lock Sounder on Siren on Unconfirmed reset Confirmed reset Global Confirm Profiles Language Restore Defaults Installer Code Installer Text Remote Needs Entry P Response uto Rearm 7 Siren Delay Siren Time Loudspeaker Volume Entry larm Delay Supervision Jamming Force Set Tamper Omit CSID Code Silence lerts 7 VIEW LOG 8 OUT Panel Comms Panel Ethernet ppears only in a Partitioned system (or when zones have a type other than Not Used. ppears only in a Level Setting system. ppears only when Report Type=Fast Format 4 ppears when Report Type=CID or SI 5 Options visible depend on communications module fitted. 6 ppears when zone is given a type other than Not Used. 7 ppears only when System Options DD4 Confirmation is off. 8 ppears only when device learned in. Page 5
20 Zone Types & ttributes (Hint: You can select a zone type quickly by keying the number shown in brackets after the type s name, for example: 05 to select larm bort, 0 to select Panic larm, to select External PSU /C Fail. The number does not appear on the keypad display.) Not Used (00) The alarm system will not respond when an event triggers this detector. Panic larm (0). Operating a device programmed as Panic larm (P) will start an audible alarm. If a communications module is fitted there may also be an alarm transmission to the larm Receiving Centre (RC), depending on how you have programmed the RC Reporting option. P alarms operate whether the system is set or unset. Fire larm (0). Smoke or heat detectors connected to Fire larm zones cause the sirens to give a pulsing fire signal. Fire alarms operate whether the system is set or unset, and will always trigger communications, if a communications module is fitted and enabled. Normal larm (0). zone programmed as Normal larm will start an alarm when the system is set. (See Zone ttributes on page 7.) 4 Hour larm (04). ctivating this zone causes an alarm whether the system is set or unset. Final Exit (05). Zones of this type must be the last detector to be activated on exit, or the first to be activated on entry. You can use zones of this type to finally set the system, or to start the entry procedure. Note: If you give a Final Exit zone any of the Part Set attributes then you can program that zone to behave like a Normal larm zone if the user part sets the system. Entry Route (06). Use this zone type for detectors sited between the Final Exit door/detector and the keypad. If an Entry Route zone is triggered when the system is set, an alarm will occur. If the entry/exit timer is running when an Entry Route zone is triggered then no alarm occurs until the entry/exit timer expires. Note: If you give an Entry Route zone one of the Part Set attributes then you can program that zone to behave like a Final Exit zone if the user part sets the system. Technical larm (07). Use this zone type when you want to monitor equipment, for example a freezer, without raising a full alarm. If a technical alarm zone is activated (and the control unit correctly programmed) then the control unit starts communication and logs the event. If the technical alarm occurs while the system is set, then system makes no audible alarm. When a user unsets the system the keypad shows an alert. If a technical alarm zone is activated while the system is unset then the system starts an alert immediately and gives a brief tone from the keypad every few seconds. When a user enters a valid access code the keypad stops the tone and displays the zone causing the alarm. When the user acknowledges the alert by pressing Y the control unit resets the technical alarm ready for the next event. Key Switch Momentary (08). Use this zone type to connect a momentary keyswitch to a single zone. In a Part Setting system the keyswitch can Full Set or unset. In a Partitioned system you can allocate the keyswitch to one or more partitions. Each time a user operates the keyswitch the control unit changes the current set state. Key Switch Latched (09). Use this zone type to connect a fixed position keyswitch to a single zone. In a Part Setting system the keyswitch can Full Set or unset. s with Momentary keyswitches, you can allocate the zone to one or more Partitions (see above). When the user closes the keyswitch contacts the control unit sets the allocated Partition. When the user opens the contacts the control unit unsets the allocated Partition. Page 6
21 Notes:. The keyswitch zone types are intended for use on zones that connect to an access control keypad, electronic key or other type of hardwired device used to set or unset the system.. When the user operates the keyswitch while the system is unset then the control unit starts the programmed exit mode.. When the user operates the keyswitch while the system is set then the control unit unsets the system immediately. 4. The user cannot reset the system from a Keyswitch zone. 5. Do not assign more than one Latched Key Switch zone to a partition. Tamper (0) Use this zone type to monitor the tamper status of external equipment. The control unit monitors a Tamper zone at all times. When triggered in the unset condition, only internal sounders operate. When triggered in the set condition, the alarm response determines whether external sounders, strobe and communications also respond to the alarm. External PSU /C Fail () Use this zone type to monitor the /C Fail output of an external power supply unit. If a power supply unit triggers a zone with this type then the control unit waits for a random time between 5 and 59 minutes before activating any output programmed as C Fail and causes an alert that displays External mains fail on the keypad. If the alarm system is set then the control unit logs the event, starts any programmed communication, but does not start an alarm. External PSU attery Fault () Use this zone type to monitor the attery Fault output of an external power supply unit. If an external PSU triggers a zone with this type then the control unit activates any output programmed as attery Fault and causes an alert that displays External attery Fault on the keypad. If the alarm system is set then the control unit logs the event, starts any programmed communication, but does not start an alarm. External PSU Low Volts (). Use this zone type to monitor the Low attery output of an external power supply unit. If a power supply triggers a zone with this type then the control unit activates any output programmed as Low attery and causes an alert that displays External Low attery on the keypad. If the alarm system is set then the control unit logs the event, starts any programmed communication, but does not start an alarm. External PSU Fault (4). Use this zone type to monitor the fault output of an external PSU. If a power supply triggers a zone with this type then the control unit activates any output programmed as External PSU Fault and causes an alert that displays External power fault on the keypad. If the alarm system is set then the control unit logs the event, starts any programmed communication, but does not start an alarm. Zone ttributes Note: a)this menu does not appear if a zone has the type Not Used. b) Some attributes are not available for certain zone types. The display shows the available attributes for the zone type you select. Chime When enabled by the user, the system gives a non-alarm warning tone when any zones programmed as Chime are opened. This facility operates only while the system is unset. Soak Test Use this zone attribute if you want to place under long term test a detector that you suspect is giving false alarms. Zones with this attribute are disabled for 4 days after you return the control unit to user/unset mode. If the zone remains inactive for the whole fourteen days then after midnight on the 4th day the control unit returns the zone to normal use. If the zone is activated during those 4 days while the system is set then the control unit logs the event as a Soak Test Fail Zn (n is the zone number) without sounding any sirens or starting communications. The Page 7
22 control unit also lights the red LEDs around the navigation key on the keypad to alert the user. You can apply the soak test attribute to Normal larm, Entry Route and Tamper zone types. Double Knock Zones programmed with this attribute will cause an alarm only if the zone is EITHER triggered, restored and triggered again within a five minute period, OR if the zone remains active for 0 seconds. You can apply the Double Knock attribute to the Normal larm and Entry Route zone types. Part Set (Not visible in a partitioned system.) When a user presses button (part set), the control unit sets only those zones where the Part Set attribute = Yes. Part Set C (Not visible in a partitioned system.) When a user presses button C the control unit sets only those zones where Part Set C attribute = Yes. Part Set D (Not visible in a partitioned system.) When a user presses button D the control unit sets only those zones where Part Set D attribute = Yes. Part Set (Not visible in a Part Setting system.) When a partition is Part Set, zones in that partition with this attribute are set. Note that if a zone is in more than one partition, all partitions have to be set or part set before this zone will be set. Omittable This attribute applies to Normal larm, 4hr and Technical zone types only. ) When a zone has this attribute, a user can omit it before setting the system. ) If a user tries to set the system when a zone with this attribute is open (active) the control unit alerts them and pauses the setting procedure. The user can acknowledge the alert by pressing Y and continue setting. You must enable this feature in the System Options User ccess Quick Omit menu. Force Set Omit When this attribute is set to Yes a user with a remote control can set the system while the zone is open (active). (You must enable this feature in the System Options Force Set menu. Output Types You can select an output type quickly by keying the number shown in brackets after the type s name, for example: 04 to select Open/Close, 0 to select Panic larm, 9 to select General Fault. (The number does not appear on the keypad display.) With Normal polarity a transistorised output applies 0V when active and +V when inactive. With Inverted polarity the output applies +V when active. Type: ctive when: Not Used (Never) (00) Fire larm (0) Panic larm (0) urglar larm (0) Open/Close (04) larm bort (05) Technical larm (06) Confirmed larm (07) RF Low attery (08) The control unit starts a fire alarm. The control unit starts a panic alarm. ny of the following zones are triggered: Normal larm Tamper (in a set system) Entry Route Tamper Zone (in a set system) Entry time expires 4 hour (in a set system) The system is unset. Inactive when the system is set. n alarm in the selected partition has been aborted by the user within the 90s abort period. Deactivates when the alarm is reset. There is a technical alarm. There is a confirmed alarm. Deactivates when the system is reset. wirefree detector reports a low battery. The output remains active until all detectors stop reporting low batteries. Page 8
23 Type: RF Supervision (09) RF Jamming (0) RF Fault () Panel /C Fail () Panel attery Fault () External PSU Low Volts (4) External PSU Fault (5) ctive when: There is a supervision failure on any radio zone. The output remains active until all supervision failures are reset. The control unit detects jamming. The output remains on until all jamming disappears. There are any of the following faults: RF Low attery, RF supervision, RF jamming. Either Mains power is absent for between 5 and 59 minutes, OR a zone of type External PSU /C Fail has been triggered. The control unit deactivates the output if a user keys in a valid access code after mains power has been restored. The control unit detects a fault with its backup battery, OR a zone of type External PSU attery Fault has been triggered. If the alert was caused by an External PSU attery Fault zone then the control unit deactivates the output when the zone has been restored and a user has acknowledges the fault by entering a valid access code. If the alert was caused by a fault with the control unit s backup battery then the control unit deactivates the output when it detects a good battery and a user acknowledges the alert. Note: To cause the control unit to check its backup battery enter and leave the Installer Menu. n external power supply has triggered an External PSU Low Volts zone. The control unit deactivates the output when the zone has been restored and a user has acknowledges the fault by entering a valid access code. n external power supply fault signal triggers a Power output fault zone. The control unit deactivates Type: Tamper (6) Zone Omit (Setting) (7) Zone Omit (System) (8) General Fault (9) TS Test (0) Siren () Strobe () Entry Exit Follow () ctive when: the output when the zone has been restored and a user has acknowledges the fault by entering a valid access code. The control unit detects tamper on any device; deactivates when tamper is reset. The user Omits a zone while setting the system. The output deactivates when the control unit restores the zone. (Operates only when DD4 is enabled.) In the event of an unconfirmed alarm, the system will rearm itself when the confirmation timer expires. If the zone that caused the unconfirmed alarm is still active at the time of the rearm, the control unit will omit that zone and activate the output. The control unit will restore the zone and output when a user or engineer resets the system. There is any event that causes an alert indication on the keypad. (This output type appears only for Plug-by outputs.) The line fault input signal goes to V. The operation of the Line Fault input and the TS test output must comply with the requirements of SI form 75. The control unit starts a full alarm, a panic alarm or a fire alarm (the siren has a distinctive tone during a fire alarm). The control unit deactivates this output at the end of the siren time. The control unit starts a Full alarm, panic alarm or fire alarm. The output remains active until the user disarms the system. The entry or exit time starts and deactivates at the end of the entry/exit time, or if the entry/exit time is terminated. The output can be used for a separate entry/exit buzzer. Note that the output does not Page 9
24 Type: rmed (4) PIR Set Latch (5) Shock Sensor Reset (6) Walk Test (7) Smoke Sensor Reset (8) 4 Hour larm (9) Setting Complete (0) Unset Complete () Full Set Ready () Full Set () Part Set (4) ctive when: operate if the exit mode is silent set or instant set. The system is full or part set. The system is set. Inactive when the system is unset or an alarm condition occurs. The output is active for one second when a reset is performed or when the control unit leaves installer mode. Exit time starts. The output remains active for five seconds. Use this output to reset shock sensors (for example, the "Viper"). user starts Installer- or User Walk Tests. lso active during the time between silencing and resetting the system. This output can be used on movement detectors that are able to switch off the Walk Test lamp in any state other than a Walk Test. This output is active (0V) all the time except when a user acknowledges a fire alarm: after which the control unit deactivates the output for three seconds. This output type is designed to be connected to low-voltage smoke detector reset terminals. The control unit starts a 4 hour alarm. The control unit finishes setting. ctive for 0 seconds. Someone unsets the system or disarms it after an alarm. The output is active for 0 seconds. None of the detectors are reporting alarm signals. The system is full set. If the system is partitioned, then the output is active only when all assigned partitions are Full Set. The system is part set. Type: Part Set (5) Part Set C (6) Part Set D (7) ctive when: i-on40 Setting Part Set. Deactivated on unsetting Part Set. (vailable only in a Part Setting system) Setting Part Set C. Deactivated on unsetting Part Set C. (vailable only in a Part Setting system) Setting Part Set D. Deactivated on unsetting Part Set D. (vailable only in a Part Setting system) Set Fail (8) set command fails. Remains active until the user acknowledges the set fail. Zone Follow (9) Zone larm (40) User Defined (4) specified zone has been triggered. If you select this type for a zone then the display shows an extra Follow option for the output. Use this option to select the zone you wish the output to follow. (You can follow a not used zone.) The selected zone causes an alarm. Deactivated when the alarm has been reset. When programming this output type the installer can select a specific zone for the output to follow. (You can follow a not used zone.) The user switches the output on or off from the keypad, or a remote control. ssign this output type to any outputs that you want the user to control. Page 0
25 Exit Modes When choosing an exit mode for a partition or a part set, the available options are: Final Door Set Timed Set Instant Set Silent Set Use this option to complete setting the system by closing a door fitted with a Final Exit zone detector. Note that the exit time is infinite in this option. The system allows a seven second settling time after closing a final door. Note: Do not try to make a PIR zone act as a Final Exit. Radio PIR detectors have a lock out period after each activation in order to conserve battery power. When you set (or part set) the system a PIR may still be in lockout, during which it cannot send a signal to complete the setting process. Use this option to make the system set after a delay. Use the Exit time menu to choose the delay. The system sets immediately and without any tones. The system sets after the exit time programmed in the Entry/Exit Time menu but does not give any exit tones. When the system sets the keypad gives a double beep. The keypad gives a double beep confirmation tone at the end of all setting modes. 7. Maintenance The control unit should be inspected once per year. t each inspection: Check the control unit for obvious signs of damage to the case or its lid. Check the action of the back tamper. Check the condition of the control unit standby battery. Check the cabling to the keypad(s) for signs of damage or wear. Check the keypads for obvious signs of damage. Test the action of all buttons on all keypads. Clean the keypad surface and display. To clean the keypad wipe the surface with a clean soft dry cloth. Do not use water, solvents or any proprietary cleaning materials. Monitor the signal strength and battery condition of all detectors, radio keypads, remote controls, Ps and radio sounders. Test each device. Replace batteries as recommended by the manufacturer s instructions. Gently clean the lenses of any PIRs with a clean, soft dry cloth. Do not use water, solvents or any proprietary cleaning materials. Walk test all detectors. Test any external sounders and strobes. Page
26 General Product name Product Description Manufacturer Environmental Operating temperature Humidity Case material Dimensions: End station Keypad Weight: End station Keypad 8. Technical Specification Capacities i-on zone hybrid endstation with remote keypads. Cooper Security Ltd. Class II. Tested -0 to +55 C. 0 to 75% RH, noncondensing. S LG-F4. 84 x 45 x 94, mm HxWxD. 5 x 56 x 4, mm HxWxD. kg (without stand-by battery). 0.6 kg Zones 6 wired, 4 radio Keypads 4 wired, 4 radio Outputs 6 wired (comprising two voltage free contacts, 4 transistorised of which are provided on separate wiring harnesses). 8 radio output channels. Internal Clock ±0 minutes over one year (depending on the accuracy of the mains supply frequency). Remote 50 controls Panic larms 50 External 4 Radio Sirens Log capacity Up to,000 events: 750 mandatory events, 50 non-mandatory. Stored in EEPROM memory, available for at least 0 years without power. Security Security Grade Radio detector differs Grade. 6,777,4 ( 4 -). Radio Programmable. Supervision Number of 50 plus installer access codes ccess code 0,000 differs. 4 digit differs codes, all four digits may be any number 0 to 9. Code blocking locked for 90s after 0 incorrect codes in series. Proximity tag 4,94,967,96 ( ) differs Radio Radio Section Transmitter range Power Supply Operating frequency MHz Narrowband. EN EN The range of the transmitters compatible with this control unit depends on the environment in which they are installed. s a guideline, most transmitters will work up 00m range in free space conditions. This product complies with the requirements of EN50-6 Type power supply at Grade and environmental class. Mains power 0VC +0%/-5%, supply 70m max, 50Hz. End station.7vdc,.5 max psu End station 0m min. consumption 0m max Communicator 50m max consumption Keypad 0m (backlight off) consumption 45m (backlight on) 65m (backlight on max) Standby V, 7h sealed lead acid. attery Standby time: See Power vailabillity on page 4. Max recharge less than 7 hours. time: attery 70m charge limit V ux supply (inc LS) 4V4 supply V Keypad bus.7vdc 850m max. 4.4V 0m.7V 400m max Page
27 Monitoring includes Mains fail, battery low voltage, battery failure. Electromagnetic Compatibility Immunity Emissions Outputs O/P - O/P - 4 O/P 5-6 LS (loudspeaker) Fuses Conforms to EN Conforms to EN Voltage free, single pole relay contacts rated Open collector transistor, +VDC when inactive, 0V when active. 500m max. Open collector transistor +VDC when inactive, 0V when active, 50m max. Min impedance 6 Ohm, current consumption from Vux = 80m in alarm. The control unit has a replaceable T50m mains fuse. Electrical Safety Conforms to EN Compliance Statements This product is suitable for use in systems designed to comply with PD 666: 004 at grade and environmental class II. This product complies with the requirements of EN50- at grade and environmental class II. This product complies with the requirements of EN50-6:008 at grade and environmental class II. When fitted with an i-sd0 this equipment is compliant with EN It allows the alarm transmission system to meet the performance requirements of EN 50- :006 TS provided that: a) It is installed in accordance with the installation instructions. b) The connected PSTN is functioning normally. If the installer selects a noncompliant configuration then they must remove or adjust compliance labelling Page
28 Compatible Equipment 70rEUR rEUR-00 70rEUR-00 7rEUR-00 74rEUR-00 70rEUR-00 76rEUR-50 76rEUR-60 74rEUR-00/0 74rEUR-05/06 78rEUR-00/04 79rEUR-5 760ES 76rEUR rEUR-50 Multi-function transmitter Two button P/tilt switch transmitter Two button P Pet tolerant PIR PIR Transmitter (Small case) Smoke Detector Transmitter Long range hand held P Short range hand held P CC/FSL Door Contact Transmitter (white) CC/FSL Door Contact Transmitter (brown) Spyder shock sensor (white/brown) Sentrol glass break detector (no tamper) External Wireless sounder Two Channel Receiver Eight Channel Receiver 770rEUR-00 77rEUR EUR EUR UK-00 i-fb0 i-kp0 i-rc0 i-rk0 i-sd0 i-dig0 i-gsm0 xcelr xcelrpt xcelw xcelwpt i-on40 Wireless ccessory Module Info Module GPRS module Ethernet module Speaker boxed Four button remote control Keypad Relay Card Radio Keypad PSTN Communication module with speech dialling PSTN Communication (RC only). GSM communications module Radio PIR Pet tolerant radio PIR Wired PIR Pet tolerant wired PIR Product Support (UK) Tel: +44 (0) vailable between: 08:5-:0 and :00-7:00 Monday to Friday. Product Support Fax: (0594) Part Number Issue Page 4
Security System Installation Guide
Security System Installation Guide Cooper Security Ltd. 00 Every effort has been made to ensure that the contents of this book are correct. However, neither the authors nor Cooper Security Limited accept
Security System Installation and Programming Guide
Security System Installation and Programming Guide Cooper Security Ltd. 2009 Every effort has been made to ensure that the contents of this book are correct. However, neither the authors nor Cooper Security
Security System User Guide
Security System User Guide Contents 1. Introduction... 1 Controls and Displays... 3 Displays... 3 Controls:... 4 2. Everyday Operation... 5 Access to the System... 5 Entering and Leaving the Protected
9452/9453 Installation and User Guide
9452/9453 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4-Channel Minicom 496330 Issue 1 1 of 10 9452/3 Introduction The 9452 and
500r+ Installation and User Guide
500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and
TS510 & TS500. Installation & User Guide. Compatible Equipment
Installation & User Guide Compatible Equipment TS510 REM - Remote Keypad 9040 - Loudspeaker DC54/58 - Digital Communicator SD1+ - Speech Dialler 496525 Issue A 1 of 10 TS510 and TS500 Overview Introduction
HARDWIRED CONTROL PANELS
USER GUIDE 9651 HARDWIRED CONTROL PANELS Contents 1. Introduction...3 The Alarm System...3 The Keypad...3 About This Guide...5 2. Everyday Operation...6 How Do I Know if the System is Working?...6 Setting
ACTIVE 5 ENGINEERING MANUAL
ACTIVE 5 ENGINEERING MANUAL C & K Systems Ltd C031-066 Issue 3 THE ACTIVE 5 INSTALLATION MANUAL. Date: Feb 1997 INTRODUCTION. The Active 5 is a microprocessor controlled intruder alarm panel. It features
ACP10 10 Zone Intruder Alarm System
ACP10 10 Zone Intruder Alarm System Installation Manual Contents 1. System Overview... 4 System Configuration... 4 Control Panel... 4 Remote Keypads... 5 LED Remote Keypad... 5 LCD Remote Keypad... 5 USB-Link...
i 70 Installation Manual V1.04 Contents Grade 2 Wireless Intruder Alarm System YOUR SECURITY IS OUR PRIORITY Installation Instructions 2
YOUR SECURITY IS OUR PRIORITY Contents Installation Instructions 2 Operation Instructions Trouble shooting Technical Specification 8 25 31 i 70 Grade 2 Wireless Intruder Alarm System Global Security Devices
CONTENTS 4. HOW TO UNSET THE PANEL...7
Pi-8 USER MANUAL CONTENTS 1. THE KEYPAD AND ITS OPERATION...3 1.1 DESCRIPTION OF THE KEYPAD LEDS... 3 1.1.1 READY LED (RED)...3 1.1.2 TAMPER LED (RED)...3 1.1.3 POWER LED (GREEN)...3 1.1.4 CIRCUIT LEDs
9448 Installation and User Guide
9448 Installation and User Guide Compatible Equipment 9040 Internal Sounder 660 Speech communicator 496327 Issue 1 1 of 6 9448 INTRODUCTION The 9448 is a 3 zone control panel with separate Entry/Exit and
9x5x PROGRAMMING GUIDE
9x5x PROGRAMMING GUIDE HARDWIRED CONTROL UNITS 9853, 9752, 9751 Hardwired Control Unit Programming Guide This document applies to control panels using software version 4.2.x. Cooper Security Ltd. 2005
TS590. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT 0 ESC
TS590 Intruder Alarm Control Panel 7:0 0 Jan _ ~ A B 5 6 C 7 8 9 D 0 ESC Setting the System Enter your passcode XXXX then leave the protected area. Unsetting the System Go directly to the keypad and en
SECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
User s Information Guide R1A
HSC505-R Home Security Controller - User Manual Release R1a Pi HSC505 and Pi HSC505R Home Security Controller User s Information Guide R1A Page 1 QD Dynamics (Pty) Ltd reserves the right to make changes
1pcs. 1pcs. 2pcs 1pcs 1pcs 2pcs
Home security alarm system LX-HS06 Instruction Brief introduction LX-HS06 is a set of entirely new English home security alarm system, it uses advanced MCU control and SMD technology. it innovate multiple
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual
SUPA8 Quick Setup & User Manual QUICK SETUP & INSTALLATION CONTENTS FACTORY DEFAULTS... 1 INSTALLATION OF THE SECURITY SYSTEM... 2 COMMISSIONING THE DIALLER PANEL... 5 ZONE INPUT CONNECTIONS... 7 PANEL
IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18
INHEP DIGITAL IDS S E C U R I T Y Users Guide to Keypad Functions MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Away Arm Stay
D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST
D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head Office only WWW.NESS.COM.AU Australia s largest
USER GUIDE HARDWIRED CONTROL UNIT
USER GUIDE HARDWIRED CONTROL UNIT 1. Introduction...3 Alarm System...3 Keypad...4 Proximity Tags...4 Mains Power Failures...6 About this Guide...7 2. Everyday Operation...8 Setting the System...8 General
Galaxy 2 Series. User Guide. Honeywell Security
Galaxy 2 Series User Guide Honeywell Security Table of Contents Table of Contents... iii Introduction...1 Controlling Your Alarm System...2 Users... 2 Groups... 2 Keypads...3 Prox Tags/Cards... 3 Wireless
NESS D16. 16 Zone Control Panel and Dialler OWNER S MANUAL
NESS D16 16 Zone Control Panel and Dialler OWNER S MANUAL REVISION 2, JULY 2001 Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head Office only WWW.NESS.COM.AU Australia
Master User Guide Premier Elite 24/48/88/168/640
Master User Guide Premier Elite 24/48/88/168/640 INS177-7 Overview Premier Elite Series Master User Guide Contents 1. Overview... 4 Introduction... 4 Keypads... 6 Emergency Keys... 7 The Quick Arm Keys...
IDS X-Series User Manual 700-398-01D Issued July 2012
1 2 Contents 1. Introduction to the IDS X-Series Panels... 7 2. Before Operating Your Alarm System... 7 3. Understanding the Keypad LEDs... 8 3.1 Viewing Data on an LED Keypad... 12 3.1.1 LED Status Indicators...
Accenta/Optima. Engineer s Manual. Honeywell Security. 8SP399A - Accenta mini panel with remote LCD keypad and communicator outputs.
Reset Chime Omit Prog Set Power PA Day ZONE PA PA Accenta/Optima Engineer s Manual Power Gen" ACCENTA! " # $ % & Zones Power Attack Tamper Day 0 1 2 3 5 6 7 8 Chime Omit Reset Prog 4 9 Set Accenta/! mini
Using your LED Plus keypad
Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced
Users Guide to Keypad Functions
Users Guide to Keypad Functions MANUAL NO. 700-175-01J ISSUED JAN 2002 VERSION 1.41 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Panic Fire Medical Away Arm Stay Arm Stay Arm &
SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL
SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL PINKERTON Quick Setup & User Manual QUICK SETUP & INSTALLATION CONTENTS FACTORY DEFAULTS...1 INSTALLATION OF THE SECURITY SYSTEM...2 COMMISSIONING
WIRELESS HOME ALARM SYSTEM (WHA1)
WIRELESS HOME ALARM SYSTEM (WHA1) IMPORTANT : PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING TO INSTALL AND OPERATE THIS ALARM SYSTEM. SAFETY Please note: Before you start to install this alarm, we
Control/Communicator Installation Manual
DAS NETWORX NX-8 Control/Communicator Installation Manual Page General Description... 2 Ordering Information... 2 Option Definitions... 2 Programming the LED Code Pads... 4 Programming the NX-8... 8 Types
NetworX NX-6V2. LED Keypad User Manual
NetworX NX-6V2 LED Keypad User Manual POWER Light is on when AC power is present; flashes to indicate a low battery condition. ARMED Light is on when armed; off when disarmed; flashes to indicate a previous
Ademco Vista-20P/First Alert FA-168C Basic Commands
Zones 64 total Ademco Vista-20P/First Alert FA-168C Basic Commands Wireless Yes, Zones 09 to 48 + 16 Keyfob Zones (Zones 49 to 64) Batteries Downloadable Partitions 2 12 volt Rechargable inside main Panel,
tattletale User Guide Consumer unit version 2.48 1 P a g e
tattletale User Guide Consumer unit version 2.48 1 P a g e Contents Basic 1... 4 Base Unit Features... 4 Initial Setup... 4 Arming... 5 Disarming... 5 Quiet Button... 5 Settings... 5 Settings 2... 6 Quick
ICP-CC488. Installation Guide ICP-CC488 Control Panel
ICP-CC488 EN Installation Guide ICP-CC488 Control Panel ICP-CC488 Installation Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems,
THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panels with Integrated Communicator INS159-9
THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL Security Control Panels with Integrated Communicator INS59-9 Contents Premier 4// Installation Manual Contents. System Overview... 4 System Architecture...4
Programming & Installation PIEZO WARNING. EN50131-3 : 2009 EN50131-6 : 2008 EN50131-5-3 : 2005 Security Grade 2 Environmental Class II RINS1347-2
Programming & Installation EN50131-3 : 2009 EN50131-6 : 2008 EN50131-5-3 : 2005 Security Grade 2 Environmental Class II PIEZO WARNING The Enforcer control panel contains a 100 dba siren, please be aware
PK5500 v1.1 Installation Instructions
PK5500 v1.1 Installation Instructions 1 2 3 4 5 6 7 8 9 * 0 # WARNING: Please refer to the System Installation Manual for information on limitations regarding product use and function and information on
astec Integrated Alarm System USER GUIDE
astec Integrated Alarm System USER GUIDE 020008599 CONTENTS Full Set, Part Set and Disarm 3 Instant Full Set 3 Part Set with exit time 4 Bell Test 4 Bypassing zones 4 Switch Lights on/off 4 Bypass (24
IMPORTANT USER INFORMATION
TM C P 8 L L C D U S E R M A N UA L TM Contents Introduction................................. 1 Display Status Blanking........................ 2 IMPORTANT USER INFORMATION.............. 2 Full Setting
Solution 16 plus. User Guide Security System
Solution 16 plus EN Security System Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd ( Bosch ). All rights are reserved.you may download
INSTALLATION AND PROGRAMMING GUIDE HARDWIRED CONTROL PANEL
INSTALLATION AND PROGRAMMING GUIDE 9651 HARDWIRED CONTROL PANEL 9651 Hardwired Control Panel Installation and Programming Guide Cooper Security Ltd. 2004 Every effort has been made to ensure that the contents
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
How To Control A Car Alarm On A Car With A Remote Control System
MODEL CA100 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM Black Antenna Wire 6 Pin 6 Pin Mini Connector Valet Switch Blue LED Indicator Blue Wire: (-) 200mA Unlock
Master User Guide Premier 24/48/88/168. Issue 6
Master User Guide Premier 24/48/88/168 Issue 6 Overview Premier Series Master User Guide Contents 1. Overview...4 Introduction... 4 Keypads... 6 Emergency Keys...7 The Quick Arm Keys...8 Keypad Lock...8
HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide
HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide PIMA Electronic Systems Ltd. 5 Hatzoref Street, Holon 58856, Israel +972-3-5587722 +972-3-5500442 [email protected] http://www.pima-alarms.com
SECURIT 800L+ CONTROL PANEL
INSTALLATION MANUAL SECURIT 800L+ CONTROL PANEL With additional options CONTENTS Warnings 2 Standards 2 Warranty Statement 2 Product Description 2 Available Parts 2 Intended use 2 Specifications 3 Processor
Solution-16 Operators Manual ISSUE 1.60
Solution-16 Operators Manual ISSUE 1.60 !"#$%&"'()*+ Operators Manual Copyright 2002 by, SYDNEY, AUSTRALIA Document Part Number MA880O DOCUMENT ISSUE 1.60 Printed 22 March 2002 This documentation is provided
Crow Limited Warranty. Print Version 017
Crow Limited Warranty (Crow) warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the last day of the week and year whose
SECURITY SYSTEM NOTES
SECURITY SYSTEM NOTES Installing/Service Company For Service Call Central Station Duress Code FUNCTION CODES Function Code Controls Function This system is is not partitioned. EMERGENCY ACTIVATION KEYS
Wireless Home Security System Product Manual (Model #80355)
Wireless Home Security System Product Manual (Model #80355) Installation Instructions During set-up, if no key is pressed for 15 seconds it will come out of the setup mode and you will have to start over.
THANK YOU FOR VOTING TEXECOM MASTER USER MANUAL. Security Control Panels with Integrated Communicator. Issue 6
THANK YOU FOR VOTING TEXECOM MASTER USER MANUAL Security Control Panels with Integrated Communicator Issue Contents Premier 4// Master User Manual Contents. About the System... Introduction... About this
Intruder alarm system Engineering Information
ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE 8 ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE 8 Power Power Chime Omit Chime Omit Prog Prog Set Set PA PA Chime Omit Prog Chime Omit Set PA Prog Set PA Intruder alarm
PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.
WIRELESS AUTODIAL HOME ALARM SYSTEM AM2000 Instructions for use Important! Please read these instructions carefully. IMPORTANT 1 IDENTIFICATION PLEASE CONTACT BEFORE RETURNING THIS PRODUCT TO THE RETAILER
VR8. User Guide Intruder Alarm System
VR8 EN User Guide Intruder Alarm System VR8 User Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd ( Bosch ). All rights
Accenta/Optima. User Guide. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number: Honeywell Security
Accenta/Optima User Guide ZONE 1 2 3 4 5 6 7 8 9 Chime Omit Prog PA 0 1 2 3 4 5 6 7 8 9 CHIME OMIT RESET PROG SET Accenta + TA PA DAY POWER PA! " # $ % & 0 1 2 3 5 6 7 8 Chime Omit Reset Prog 4 9 Set PA
ABUS WIRELESS ALARM SYSTEM
ABUS WIRELESS ALARM SYSTEM These installation instructions are published by Security-Center GmbH & Co. KG, Linker Kreuthweg 5, D-86444 Affing/Mühlhausen. All rights including translation reserved. Reproductions
TX GSM SMS Auto-dial Alarm System. Installation and User Manual
TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses
SECURITY SYSTEM NOTES
SECURITY SYSTEM NOTES Installing/Service Company For Service Call Central Station Duress Code FUNCTION CODES Function Code Controls Function EMERGENCY ACTIVATION KEYS (check if enabled) Fire Auxiliary
!"#$%&"'()**+),-+)).( /'0%1##1%&"'(21'$1#( ISSUE 1.40
!"#$%&"'()**+),-+)).( /'0%1##1%&"'(21'$1#( ISSUE 1.40 MA8XXI 34&0(5167(410(877'(&'9#$:7:(;"
CS848E Receiver for 868GEN2 Devices Installation Sheet
CS848E Receiver for 868GEN2 Devices Installation Sheet EN 1 2 1 3 4 2 3 EN: Installation Sheet Description The CS848E Receiver adds wireless capabilities to the CS line of control panels. The CS848E allows
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
Business/Home GSM Alarm System. Installation and User Manual
Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene
EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual
EDA-Z5008 & Z5020 Radio Fire Alarm System User Manual Electro-Detectors Ltd. Electro House, Edinburgh Way Harlow, Essex, CM20 2EG UK Tel: 01279 635668. Fax 01279 450185 Email: [email protected]
FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM
FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM Page 0 Table of Contents Introduction 1 System Basics.. 1 Burglary Protection.. 1 Fire Protection.. 1 Security Codes. 1 Zones and Partitions
INSTALLATION MANUAL 5-051-719-00 CONTENTS
INSTALLATION MANUAL CHALLENGER VIII CONTROL PANEL 5-051-719-00 CONTENTS Warnings 2 Standards 2 Product Description 2 Available Parts 2 Intended use 2 Specifications 3 Processor Version 3 Power Supply 3
HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS
ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS USER MANUAL USER MANUAL ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS INTRODUCTION The (HA-841K) is a complete
Diamond + User Manual. Wireless Alarm System. Default codes: User code: 1234 Master Manager Code: 2222
Diamond + Wireless Alarm System User Manual Default codes: User code: 1234 Master Manager Code: 2222 CONTENTS CHAPTER 1: INTRODUCTION... 4 CHAPTER 2: KEYPADS / READERS... 5 CHAPTER 3: THE KEY-FOB... 6
THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panels. Issue 12
THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL Security Control Panels Issue 12 Contents Veritas 8, 8C & R8 Installation Manual Contents 1. Quick Reference and Factory Settings... 3 Programming Guide...
How To Program An Autodialer
GJD HYL005 GSM Autodialer Instruction Manual Please read these instructions before you start the installation Features: LCD display. Programmable 9 x 32 digit phone numbers for each trigger. 10 second
User Manual Wireless Alarm System RINS1548-4. PIEZO WARNING The wireless system contains a loud siren, please be aware of this after an activation
EN50131-1:2006+A1:2009 EN50131-3:2009 EN50131-6:2008 EN50131-5-3:2005+A1:2008 PD6662:2010 Security Grade 2 Environmental Class II Software Version >9.13 User Manual Wireless Alarm System RINS1548-4 PIEZO
POWER POWER ABC DEF GHI JKL ABC DEF GHI JKL COMMAND YZ COMMAND POWER ABC DEF GHI JKL COMMAND YZ USER'S GUIDE
POWER POWER POWER ABC DEF GHI JKL ABC DEF GHI JKL MNO PQR STU VWX MNO PQR STU VWX YZ COMMAND YZ COMMAND ABC DEF GHI JKL MNO PQR STU VWX COMMAND YZ USER'S GUIDE Security Command User's Guide for 9XR Command
SFC-200 SERIES LCD FIRE ALARM PANEL
SFC-200 SERIES LCD FIRE ALARM PANEL User Guide LT-954SUM SFC-200 Series LCD Version User Guide Contents Introduction... 1 About this Manual... 1 Technical Support... 1 Main Display... 1 The Buzzer and
CAPTAIN 6. USER GUIDE System ver. 6.0. 6 Zones Intruder Alarm System. PIMA Electronic Systems Ltd. www.pima-alarms.com
CAPTAIN 6 6 Zones Intruder Alarm System USER GUIDE System ver. 6.0 PIMA Electronic Systems Ltd. www.pima-alarms.com P/N 4410049, G2 XX en, Jan. 2010 2 CAPTAIN 6 User Guide SAFETY INSTRUCTIONS Your CAPTAIN-i
User Guide. Model: MAS-WA-SYS
User Guide Model: MAS-WA-SYS CONTENTS Section : Getting started... 4. General system overview. Introduction to the system.3 Items included with the system.4 Introduction to the Wireless Alarm Panel.5 Introduction
Solution 880 Operators Manual ISSUE 1.10
Solution 880 Operators Manual ISSUE 1.10 Solution 880 Operators Manual Copyright 2001 by, SYDNEY, AUSTRALIA Document Part Number MA408O DOCUMENT ISSUE 1.10 Printed 25 May 2001 This documentation is provided
EURO User Manual. Castle Care-Tech 2012 (RINS1531) Issue 2. Page 1
Contents Introduction 1 Using EURO Panel with Code or Tag 7-9 Intelligent Setting 13 Silencing the Alarm 20 Setting Individual Areas 14-17 Chime Facility 22 Omitting Inputs 18-19 Keypad Hold Up/Personal
Always on the Lookout Perfect Protection against Burglary
Always on the Lookout Perfect Protection against Burglary Terxon wired and hybrid alarm systems One system offers all possibilities Rely on experts With a qualified specialist installation contractor on
Blue Point Engineering
lue Point Engineering 10-Ch udio Controller Description: This board is designed to control the sequence or random playback by remote user switch or relay contact of 1 to 10 channels of audio files that
Memcom Emergency Telephone
Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming
D200+ Auto-Dialler Installation/Operators Manual
D200+ Auto-Dialler Installation/Operators Manual Bell System (Telephones) Ltd. Presley Way, Crownhill, Milton Keynes, MK8 0ET D200+ Software Version 1.0 Contents General Description...3 Central Station
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way
Master User Guide Premier Elite Series
Master User Guide Premier Elite Series INS177-8 Overview Premier Elite Series Master User Guide Contents 1. Overview... 5 Introduction... 5 Keypads... 7 Emergency Keys... 8 The Quick Arm Keys... 9 Keypad
HILLS Series LED Code Pad User Manual
HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2
INSTRUCTION MANUAL PC255O
INSTRUCTION MANUAL PC255O Canadian Department of Communications Notice NOTICE: The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment
CAD-05 Kit GSM Auto Dialer. Owner s Manual
CAD-05 Kit GSM Auto Dialer Owner s Manual CAD-05 Kit Manual.indd 1 Warnings: This device complies with Part 15 of the FCC rules, Operation of this device is subject to the following conditions: 1. This
Intruder alarm system Operating Instructions
New remote keypad Intruder alarm system Operating Instructions 0 2 3 4 5 6 7 8 9 CHIME OMIT RESET PROG SET Power Power 0 2 3 5 6 7 8 Chime Omit Prog 4 9 Set AccentaG3 mini Servicing organisation details
INSTALLATION GUIDE HARDWIRED CONTROL UNIT
INSTALLATION GUIDE HARDWIRED CONTROL UNIT 9751 Hardwired Control Unit Installation Guide This document applies to control panels using software versions 4.x. and 5.x. Cooper Security Ltd. 2009 Every effort
Solution 862 Operators Manual. Issue 1.00
Solution 862 Operators Manual Issue 1.00 Solution 862 Operators Manual Copyright 1998 by Electronics Design and Manufacturing Pty Limited, SYDNEY, AUSTRALIA Document Part Number MA406O Document Issue
MOBILE CALL GSM Alarm System User s Manual
MOBILE CALL GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Contents Function Introduction Alarm Host Diagram
How To Use An F145C-1 With A Sim Sims 2 (Aq) And A Sims 1 (Aux) (Aipa) (For Aq) (F145C) (Ios) (Power
First Alert FA145 Installer Notes M. Leuck 1. Programming can only be done by 6139 Alpha keypads, standard 6128 keypad cannot be used to program zones 2. Program new Master Code in section *20 (old version)
INSTALLATION GUIDE. www.security.soundstream.com FCC ID NOTICE
AL.1 AUTO SECURITY SYSTEM INSTALLATION GUIDE www.security.soundstream.com FCC ID NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: 1. This device
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One
Fire Alarm Control Panel. Family. Operating Manual
Fire Alarm Control Panel Family Operating Manual CONTENTS System Description AH-03312 System Characteristics... Fire Signal Receiving Board Description-4L... Fire Signal Receiving Board Description-8L...
LW-2000-3A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets
LW-2000-3A Wireless Auto Dial Alarm System Sentry Plus User Manual By Global Gadgets Main Features Simple to use keypad for operation and control. The system can store up to 9 telephone numbers: positions
ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems
ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems Content Introduction Preventing unauthorized access by perimeter surveillance Monitoring unauthorized access by indoor surveillance
Challenger Version 8 Basic Alarm System.
Challenger Version 8 Basic Alarm System. This document provides details of the programming requirements for getting a basic alarm system that uses PIN codes to arm/disarm/reset etc., up and running. A
Installation Guide for Hive Active Heating
Installation Guide for Hive Active Heating Important note: Installation should only ever be carried out by a qualified engineer. Technical Support If you need to contact Hive s Technical Support team during
First Alert FA140C/142C Installer Notes M. Leuck
First Alert FA140C/142C Installer Notes M. Leuck 1. Programming can only be done by 6139 Alpha keypads, standard 6128 keypad cannot be used to program zones 2. Program new Master Code in section *20 (old