gpio.ipcore: Manual Copyright 2015 taskit GmbH
|
|
|
- Augustine Ernest Burns
- 9 years ago
- Views:
Transcription
1 gpio.ipcore Manual
2 gpio.ipcore: Manual Copyright 2015 taskit GmbH gpio.ipcore All rights to this documentation and to the product(s) described herein are reserved by taskit GmbH. This document was written with care, but errors cannot be excluded. Neither the company named above nor the seller assumes legal liability for mistakes, resulting operational errors or the consequences thereof. Trademarks, company names and product names may be protected by law. This document may not be reproduced, edited, copied or distributed in part or in whole without written permission. This document was generated on T16:51:18+02:00.
3 Table of Contents gpio.ipcore 1. Overview Commissioning RS USB Booting and usage Useful tools Changing root password REST interface Example 1: Access a card at the RS485 Modbus Example 2: Access to the database Scripting LUA Python Automated starting of scripts Modbus server (MBTCP) Restinio Technical data Modbus port Debug console iii
4 List of Figures gpio.ipcore 4.1. Internal structure... 5 iv
5 List of Tables gpio.ipcore 2.1. Default login information Extensions to the LUA language on gpio.ipcore MBTCP configuration Electrical charachteristics RS485 (DSUB female connector X13) RS232 (DSUB male connector X6) v
6 1. Overview Overview The gpio.ipcore forms the interface of the GPIO system in an IP network. Along with its function as a gateway between several GPIO Modbus devices and network applications on the basis of HTTP-REST protocols, the ipcore offers a flexible script interface which allows to monitor and control the Modbus hardware connected. Both together turn the device into an indepent IO controller on which it is easy to implement processes thanks to simple programmability. Common scripting languages (Python, NodeJS and Lua) are preinstalled and configured on the ipcore. Communication is possible between different scripts or with external devices, via a lightweight database. Any keys can be exported from the database via HTTP/REST. In this way, simple communication between control script and visualisation is possible indepently of any system. Simultaneous access to the Modbus is managed by the integrated Modbus TCP server. The standard RS485 Modbus can be expanded by up to two USB Modbuses. By using taskit's GPIO modules, three separate RS485 buses (two via the USB gateway) can be managed and controlled by the ipcore. Networking of several gpio.ipcore amongst themselves is possible also. 1
7 2. Commissioning Commissioning Power is supplied via a 5V USB unit which is connected to micro USB port X14 (between the two DSUBs). The ipcore can provide supply for modules at the RS485 bus. Here, the maximum current that can be supplied via the power supply unit must be taken into account. After deduction of the own consumption of max. 1W@5V, 1800mA will remain in a 2A power supply unit for the IO cards connected RS485 The RS485 bus of the ipcore is located at X13 (DSUB socket) on pins 4 (RS485+) and 6 (RS485-). A gpio.net IO card can be connected directly by means of a normal serial 1-1 cable. In a similar manner, all other cards can be hung in a row by connecting the DSUB socket to the DSUB plug USB The two USB host ports X9 can also be used to connect a gpio.net IO card. This card then serves as a gateway between the USB and all other IO cards connected to it Booting and usage After switching on the ipcore (power supply is present, push button SW1 has been briefly pressed), the Modbus TCP server, the REST interface and the database start automatically. User-defined scripts can also be executed automatically. The gpio.ipcore obtains its IP address on its own via DHCP and uses the mdns protocol (Avahi, Bonjour, Zeroconf) to publish its IP. An ipcore can be accessed on ipcore.local. The device responds to command ping ipcore.local in a shell (Windows/MAC/Linux). The REST interface can be accessed via URL by using a browser. To ensure to above method works, Bonjour (from Apple) must be installed in Windows, and Avahi must be installed in Linux. For more configurations of the system and to upload the scripts, the device can be accessed via SSH. User Password REST interface user password SSH root taskit Table 2.1. Default login information 2.4. Useful tools The use of the following tools is recommed for easy access to the gpio.ipcore in Windows: Putty, curl, winscp. Linux usually brings all necessary tools along already Changing root password We strongly advise the user to change the default password for root access. In order to do so, login via SSH using the information from Table 2.1, Default login information. 2
8 Commissioning Run the command "passwd" to set a new password for root. It asks the user to enter the old and the new password. Afterwards - before any change is done - you need to repeat the new password. All following SSH login attempts are checked against the new password. This does not change the default password for the REST interface! See Chapter 6, Restinio for details about that interface. 3
9 3. REST interface REST interface The gpio.ipcore is accessed by HTTP GET, PUT or POST commands. The URL used either directly describes a Modbus resource ( or a key in the database ( Data is transmitted in JSON format Example 1: Access a card at the RS485 Modbus Let's assume several gpio.net cards at the bus. Address 5 is a gpio.relay card. Enquiries to the REST interface (GET) either provide a list of continuative suffixes or a simple object containing the result of the enquiry: [1, 3, 4, 5, 9] ["out","in","relay","counter"] {"Value": 1} 3.2. Example 2: Access to the database Queries (GET) about any keys will result in a tuple consisting of the key (string) and its saved value (string): {"key": "mykey", "value": "null"} {"key": "mykey", "value": "data associated with mykey"} The setting (PUT/POST) of keys is performed by writing a value to any (even if nonexistent) key. There, the data type of the value is always a string. curl anyauth user user:password data "Test" ipcore.local/shared/newkey curl anyauth user user:password data "123" ipcore.local/shared/new/test 4
10 4. Scripting Scripting The behaviour of the gpio.ipcore can be automated through scripts. In the process, the database (Redis), and Modbus and the REST servers form uniform interfaces. Supported scripting languages are Lua, Python and JavaScript. Figure 4.1, Internal structure shows the interaction of the components involved. [RS485] [USB1] [USB2] /etc/m btcp.conf MBTCP- Server RS485 USB1 USB2 nodejs LEM LUA m achine Pyt hon REST- Server HTTP, JSON Java Script LUA script Pyt hon script Dat abase Figure 4.1. Internal structure The scripts may run in parallel to each other and s enquiries to the Modbus server. The necessary Modbus libraries are preinstalled for the respective languages. Processes that, for instance, check on threshold values or intervene in a regulating manner without external assistance, that is, without additional logic from outside, can be realised completely in the ipcore itself. Nonetheless, the entire hardware connected is also available to the outside via a REST interface. The system gains full flexibility through the connection between script and database and between database and the REST server. In this way, it is possible to transmit user-defined keys whose meaning is defined by a script, to an external front. Even more complex control instructions that require changes to several Modbus modules or that are to effect state changes to the standard script, can thus be given efficiently with just one HTTP access. 5
11 Scripting Python, Lua or NodeJS scripts are saved in directory /var/ipcore/. It is recommed to create a separate subdirectory for each script. cd /var/ipcore mkdir myscript cd myscript vim myscript.py chmod +x myscript.py The following scripts are examples of this: 4.1. LUA The following script searches for a gpio.ai module in all buses available and continuously records measurements issued by the standard output. #! /usr/bin/lem /etc/mbtcp.conf --[[ 1. Look for a gpio.ai module on all busses 2. Configure gpio.ai 3. Get data ]] -- return card type function get_card_type(id) _, _, ct, _, _ = string.match(id, "^(.*):(.*):(.*):(.*):(.*)$") ct = "0x".. ct ct = tonumber(ct) if ct == 0x0200 then return "AO" elseif ct == 0x0100 then return "AI" elseif (ct >= 0x0010) and (ct <= 0x009F) then return "DIO" elseif (ct >= 0x00A0) and (ct <= 0x00FF) then return "Relais" return nil -- return bus and Modbus ID of the first card matching type function find_card_type(type) bus_list = tml.get_busses() for _, bus in ipairs(bus_list) do for i = 1, 16, 1 do ret, id = tml.report_id(bus, i) if ret == 0 then if get_card_type(id) == type then return bus, i return nil local bus, mb_id = find_card_type("ai") tml.write_regs(bus, mb_id, 0x0100, {65535, 2}) print("bus: ".. bus.. " id: ".. mb_id) print("\nin0... IN7 in mv") while true do -- read IN0 to IN7 ret, v = tml.read_input_regs(bus, mb_id, 0, 8) 6
12 Scripting if ret == 0 then -- output data as mv for i = 1, #v, 1 do io.write(string.format("%7.2f ", v[i]*4096/65535)) io.write("\r") io.flush() else print("error: ".. ret) -- sleep 1 second lem.sleep_msec(1000) The Lua interpreter has been expanded by various functions for easy access to the Modbus hardware. Table 4.1, Extensions to the LUA language on gpio.ipcore provides information on the functions added by taskit GmbH. Function definition Signature Description name = lem.get_name() nil string Returns the interpreter's name and version information. time = lem.get_msec() nil number Returns system timer in milliseconds. rc, obuf = tml.modbus_command(bus, id, cmd, ibuf) rc, regs = tml.read_holding_regs(bus, id, addr, n) rc, regs = tml.read_input_regs(bus, id, addr, n) rc = tml.write_regs(bus, id, addr, regs) rc, bits = tml.read_coils(bus, id, addr, n) rc, bits = tml.read_inputs(bus, id, addr, n) rc = tml.write_coils(bus, id, addr, bits) rc, id_string = tml.report_id(bus, id) (string, number, number, table) (number, table) (string, number, number, number) (number, table) (string, number, number, number) (number, table) (string, number, number, table) number (string, number, number, number) (number, table) (string, number, number, number) (number, table) (string, number, number, table) number (string, number) (number, string) A generic Modbus command cmd is s to the server identified by bus. Parameters are stored as numbers in the table ibuf. The Modbus device is addressed using id. An error code rc and output values (e.g. Modbus registers) as table of numbers obuf are returned. Reads n holding registers starting at addr. Returns errorcode rc and a table of registers (numbers) regs. Same as tml.read_holding_regs but for input registers. Writes register set regs (table of numbers) starting at addr. Similar to tml.read_holding_regs but for read-/writable bit values. Bits are returned in table bits (numbers). A logic false is represented by 0, anything else equals true. Same as tml.read_coils but for read-only bit values. Same as tml.write_regs but for bitwise data. Bits are taken from table bits (numbers). A logic false is represented by 0, anything else equals true. Returns the identification string id_string for the addressed Modbus device (bus, id). 7
13 Scripting Function definition Signature Description bus_list = tml.get_busses() nil -> table Returns a list of available Modbus server connections as table of strings. Those strings are used as bus parameter in all tml.* commands. Table 4.1. Extensions to the LUA language on gpio.ipcore 4.2. Python In this example, a digital input and a relay of the gpio.relay card is connected to the internal database. These can then be used via the REST interface on URL ipcore.local/shared/button and The actions standing behind these URLs can, of course, turn out to be far more complex than in this example. #!/usr/bin/env python2.7 import redis from pymodbus.client.sync import ModbusTcpClient r = redis.strictredis(host = ' ', port = 6379, db = 0) mb = ModbusTcpClient(" ", 12346) oldbuttonstate = False oldrelaystate = False while True: buttonstate = mb.read_discrete_inputs(unit = 8, address = 2).bits[0] if oldbuttonstate!= buttonstate: oldbuttonstate = buttonstate if buttonstate == True: print "Button pressed" r.incr('button') relaystate = r.get('relay') if oldrelaystate!= relaystate: oldrelaystate = relaystate if relaystate == "1": print "Turning relay on" mb.write_coil(unit = 8, address = 4, value = 1) else: print "Turning relay off" mb.write_coil(unit = 8, address = 4, value = 0) 4.3. Automated starting of scripts The two previous scripts both contain in their first line a construct in the form of #! command parameter. This helps the system to start the appropriate interpreter for the script. If the data has been generated as described in the last paragraph, it can be easily started and stopped by the system automatically. The following steps are required to have myscript.py managed by the system: mkdir /service/myscript cd /service/myscript ln s /var/ipcore/myscript/myscript.py run 8
14 Scripting The script is now executed promptly and after each start of the system. Should it crash for any reason, it will be restarted. Here, there is a pause of one second to prevent a system from being blocked due to an erroneous script. The script can be stopped via svc d / service/myscript and be restarted via svc u /service/myscript. If it is meant to be removed permanently, the above directory can simply be deleted ( rm rf /service/ myscript ) without touching on the original ( /var/ipcore/myscript/myscript.py ). Lua scripts are executed by interpreter lem. This is a Lua interpreter already offering Modbus support and some auxiliary functions. The configuration file of the Modbus server is transmitted to lem as a parameter, simplifying to select the appropriate port and IP address of an individual bus in your script. 9
15 Modbus server (MBTCP) 5. Modbus server (MBTCP) For each of the ipcore's serial ports - including the two USB hosts - an instance of the Modbus TCP server (MBTCP) can be launched. The server manages access to the devices that are attached to its related serial port. It configures the hardware, queques requests and finally submits the results to their originators. MBTCP provides a standard Modbus TCP and an ASCII connection for debugging and simple programs that do not need the Modbus TCP stack. The user is free to use either. The configuration file is located in "/etc/mbtcp.conf". It contains all the vital information for the MBTCP servers and clients. By default, there are three sections: RS485, USB1 and USB2. Parameters used for LEM and the Modbus servers are stored as simple key-value pairs with an equals sign as delimiter between key and value. A sections begins with its name in square brackets and s with the start of the next section or the of file. The following except makes this more clear. [USB1] dev=/dev/usb1 mode=ascii tcp_port=12346 ascii_port=33334 host=localhost timeout=100 [RS485]... Table 5.1, MBTCP configuration describes the config items, their use and default values. Some items from this configuration are also used by the LUA machine (LEM). Item MBTCP LEM Default value Description dev yes no The device file used as Modbus connection baud_rate yes no 9600 Selects connection speed data_bits yes no 8 Bits used per character parity yes no even Method user for parity checking stop_bits yes no 1 Number of stop bits per character media yes no rs485 Selects between RS232 and RS485 handling mode yes no rtu Modbus mode on serial line (rtu or ascii) timeout yes no 1000 Max. time in ms used for packet reception host no yes Host to connect to bind yes no Interface for listening max_conn yes no 16 Max. number of open connections handled by server tcp_port yes no Port used for Modbus TCP ascii_port yes yes Port used for Modbus ASCII protocol over TCP Table 5.1. MBTCP configuration 10
16 6. Restinio Restinio Restinio is an optional service that provides the REST interfaces to Modbus and the Redis database. It is launched by default and can be stopped or restarted just like user defined scripts using the svc command. The link to its run script resides in "/service/restinio". During normal operation, Restinio does background scans of the connected Modbus devices. Thus, the REST interface offers a plug'n'play mechanism. It can be configured for each Modbus connection in Restinio's config file "/var/ipcore/restinio/restinio.conf". This file also holds the user/password combination and basic Redis setup. Since user scripts can act as HTTP servers, you might consider to disable Restinio completely. In that case, just rename the link to the run script. svc -d /service/restinio mv /service/restinio/run /service/restinio/run.disabled 11
17 7. Technical data Technical data Specification Value Unit Power supply 5 V Power consumption <700 mw Operating temperature a b C a The buzzer is limited to C but unused. b SD card socket is limited to C. Table 7.1. Electrical charachteristics 7.1. Modbus port MBTCP system uses this port as configured in "/etc/mbtcp.conf" section [RS485]. Pin Description 1 unused 2 unused a 3 unused b 4 RS GND 6 RS485-7 unused 8 unused 9 +5V c a Can be RXD of RS232 "/dev/ttys3". b Can be TXD of RS232 "/dev/ttys3". c This pin can power connected gpio.net modules. Table 7.2. RS485 (DSUB female connector X13) 7.2. Debug console This port runs a debug/emergency shell at baud 8N1. Pin Description 1 unused 2 RXD 3 TXD 4 unused 5 GND 6 unused 7 unused 8 unused 9 unused Table 7.3. RS232 (DSUB male connector X6) 12
BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter
BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6
RN-XV-RD2 Evaluation Board
RN-XV-RD2 Evaluation Board 2012 Roving Networks. All rights reserved. -1.01Version 1.0 9/28/2012 USER MANUAL OVERVIEW This document describes the hardware and software setup for Roving Networks RN-XV-RD2
Matrix 510/520 User Guide
Matrix 510/520 User Guide Introduction: Matrix 510/520 are ARM9-based Linux ready industrial computer. The key features are as follow: Matrix 520 Layout 1. ARM920T ARM Thumb Processor with 200MIPS at 180MHz,
In-System Programmer USER MANUAL RN-ISP-UM RN-WIFLYCR-UM-.01. www.rovingnetworks.com 1
RN-WIFLYCR-UM-.01 RN-ISP-UM In-System Programmer 2012 Roving Networks. All rights reserved. Version 1.1 1/19/2012 USER MANUAL www.rovingnetworks.com 1 OVERVIEW You use Roving Networks In-System-Programmer
ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
1 Serial RS232 to Ethernet Adapter Installation Guide
Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).
2015/02/07 05:41 1/23 WIZ550WEB Users' Guide
2015/02/07 05:41 1/23 WIZ550WEB Users' Guide WIZ550WEB Users' Guide Overview WIZ550web provides the lightweight webserver operating. It controls digital output or monitors digital and analogue input through
MAX T1/E1. Quick Start Guide. VoIP Gateway. Version 1.0
MAX T1/E1 TM VoIP Gateway Quick Start Guide Version 1.0 Contents INTRODUCTION 1 Hardware Needed Software Needed 1 1 NET2PHONE MAX SET UP Hardware Set Up Software Set Up Set Up Internet Protocol (IP) Address
Introduction: Implementation of the MVI56-MCM module for modbus communications:
Introduction: Implementation of the MVI56-MCM module for modbus communications: Initial configuration of the module should be done using the sample ladder file for the mvi56mcm module. This can be obtained
Installation and operation manual
Installation and operation manual Converter I-7188En-MGTCP Modbus TCP to Modbus RTU Gateway and Router I-7188En-MRTCP Modbus RTU to Modbus TCP Router. GDAŃSK 09.2006 v. 2.0.1. strona 1z1 TABLE OF CONTENTS
Command Line Interface User s Guide
Management Software AT-S85 and AT-S97 Command Line Interface User s Guide AT-MCF2000 Media Converter Series Version 1.3.0 613-000789 Rev. A Copyright 2007 Allied Telesis, Inc. All rights reserved. No part
Application Note. Terminal Server G6
MICROSENS GmbH & Co. KG Küferstr. 16 59067 Hamm/Germany Tel. +49 2381 9452-0 FAX +49 2381 9452-100 E-Mail [email protected] Web www.microsens.de Summary As of firmware version v10.6 MICROSENS Generation
3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T+ 485+ PIN6 T- 485- PIN7 R+ PIN8 R-
MODEL ATC-2004 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2004 is a 4 Port RS232/RS485 to TCP/IP converter integrated with a robust system and network management features
User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS
MODEL ATC-2000 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2000 is a RS232/RS485 to TCP/IP converter integrated with a robust system and network management features designed
A RF18 Remote control receiver MODULE
A RF18 Remote control receiver MODULE User Guide No part of this document may be reproduced or transmitted (in electronic or paper version, photocopy) without Adeunis RF consent. This document is subject
AdRadionet to IBM Bluemix Connectivity Quickstart User Guide
AdRadionet to IBM Bluemix Connectivity Quickstart User Guide Platform: EV-ADRN-WSN-1Z Evaluation Kit, AdRadionet-to-IBM-Bluemix-Connectivity January 20, 2015 Table of Contents Introduction... 3 Things
DSA-1000 / PRT-1000 Device Server / Thermal Printer
LevelOne DSA-1000 / PRT-1000 Device Server / Thermal Printer User Manual V2.0 TABLE OF CONTENTS 1. INTRODUCTION...- 3-2. DEVICE OVERVIEW...- 7-3. HARDWARE SETUP...- 10-4. SYSTEM CONFIGURATION...- 12 -,
NetBiter webscada Modbus User Manual
User Manual IntelliCom Innovation AB Pilefeltsgatan 93-95 SE-302 50 Halmstad SWEDEN Phone +46 35 17 29 90 Fax +46 35 17 29 09 email [email protected] www www.intellicom.se Revision List Revision Date
ipac-5010 User Guide + -
ipac-5010 User Guide Introduction: ipac-5010 is ARM9-based Linux ready industrial Programmable Automation Controller. The key features are as follow: 1. ARM920T ARM Thumb Processor with 200MIPS at 180MHz,
User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M)
Document code: MN67038-2_ENG Revision 1.400 Page 1 of 25 User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M) for
Acano solution. Acano Solution Installation Guide. Acano. January 2014 76-1002-03-B
Acano solution Acano Solution Installation Guide Acano January 2014 76-1002-03-B Contents Contents 1 Introduction... 3 1.1 Before You Start... 3 1.1.1 Safety information... 3 1.1.2 You will need the following
Using IDENT M System T with Modbus/TCP
Using IDENT M System T with Modbus/TCP Introduction The Pepperl+Fuchs IDENT M System T consists of two models MTT3000-F180-B12- V45-MON, which is a read only unit and the MTT6000-F120-B12-V45 which is
BLUETOOTH SERIAL PORT PROFILE. iwrap APPLICATION NOTE
BLUETOOTH SERIAL PORT PROFILE iwrap APPLICATION NOTE Thursday, 19 April 2012 Version 1.2 Copyright 2000-2012 Bluegiga Technologies All rights reserved. Bluegiga Technologies assumes no responsibility for
Wireless Communication With Arduino
Wireless Communication With Arduino Using the RN-XV to communicate over WiFi Seth Hardy [email protected] Last Updated: Nov 2012 Overview Radio: Roving Networks RN-XV XBee replacement : fits in the
Network Licensing. White Paper 0-15Apr014ks(WP02_Network) Network Licensing with the CRYPTO-BOX. White Paper
WP2 Subject: with the CRYPTO-BOX Version: Smarx OS PPK 5.90 and higher 0-15Apr014ks(WP02_Network).odt Last Update: 28 April 2014 Target Operating Systems: Windows 8/7/Vista (32 & 64 bit), XP, Linux, OS
RN-WIFLY-EVAL-UM. WiFly Evaluation Kit. 2012 Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM Version 1.32r 10/9/2012 USER MANUAL
WiFly Evaluation Kit 2012 Roving Networks. All rights reserved. Version 1.32r 10/9/2012 USER MANUAL OVERVIEW This document describes the hardware and software setup for Roving Networks evaluation kits,
ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
SecureLinx Spider Duo Quick Start Guide
SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo QUICK START GUIDE CONTENTS Overview... 2 What s In The Box... 3 Installation and Network Settings...
First Steps. Remote Access Gateway IGW/922. with DIL/NetPC ADNP/9200
Remote Access Gateway IGW/922 with DIL/NetPC ADNP/9200 First Steps SSV Embedded Systems Dünenweg 5 D-30419 Hannover Phone: +49 (0)511/40 000-0 Fax: +49 (0)511/40 000-40 E-mail: [email protected] Document
IRF2000 IWL3000 SRC1000 Application Note - Develop your own Apps with OSGi - getting started
Version 2.0 Original-Application Note ads-tec GmbH IRF2000 IWL3000 SRC1000 Application Note - Develop your own Apps with OSGi - getting started Stand: 28.10.2014 ads-tec GmbH 2014 IRF2000 IWL3000 SRC1000
SCS3205/4805 Quick Start Guide
Secure Console Server Quick Start Guide 2003 Copyright Lantronix is a trademark of Lantronix. All rights reserved. 900-287 Rev. B 8/03 QUICK START CONTENTS System Overview.......................................................2
MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual
MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual Version: 1.0.1 Dec. 2005 Table of Contents I. Introduction 2 II. Operations 2 II.1. Theory of Operation 2 II.2. Configuration (PC-PC
DiskPulse DISK CHANGE MONITOR
DiskPulse DISK CHANGE MONITOR User Manual Version 7.9 Oct 2015 www.diskpulse.com [email protected] 1 1 DiskPulse Overview...3 2 DiskPulse Product Versions...5 3 Using Desktop Product Version...6 3.1 Product
RN-131-PICTAIL & RN-171-PICTAIL Web-Server Demo Application
RN-131-PICTAIL & RN-171-PICTAIL Web-Server Demo Application 2012 Roving Networks. All rights reserved. RN-131/171-PICTAIL-UM Version 1.0 1/8/2013 OVERVIEW The RN-131 and RN-171 WiFly radio modules are
Starting a Management Session
Management Software AT-S63 Starting a Management Session AT-S63 Version 2.2.0 for the AT-9400 Layer 2+ Switches AT-S63 Version 3.0.0 for the AT-9400 Basic Layer 3 Switches 613-000817 Rev. A Copyright 2007
ACCESS 9340 and 9360 Meter Ethernet Communications Card 9340-60-ETHER
User s Guide PMCM-ETHCC-0208 2/2008 ACCESS 9340 and 9360 Meter Ethernet Communications Card 9340-60-ETHER TABLE OF CONTENTS INTRODUCTION... 2 Supported Ethernet Protocols... 2 Hardware... 2 Meter Firmware...
Alarm Messages... 15 Clearing the Hardware Alarms... 16. How to Log On... 17 Summary Page... 21 Navigation Menu... 24
Contents Introduction--1 Product Description.................................. 1 Access Procedures................................... 3 How to Recover from a Lost Password..................... 6 Upgrading
FINS Gateway For OMRON PLCs
1 Purpose This Technical Note describes how to set up a remote collaboration. A remote collaboration consists in configuring, programming or monitoring a PLC from a remote location, without the need of
Configuring the Beckhoff BK9000 Network Parameters
Configuring the Beckhoff BK9000 Network Parameters Section Title Page 1 Overview of Steps 1 2 Parts List 1 3 Required Software 1 4 Install Required Software 2 5 Configure Network Parameters 3 1 Overview
Follow these steps to prepare the module and evaluation board for testing.
2 Getting Started 2.1. Hardware Installation Procedure Follow these steps to prepare the module and evaluation board for testing. STEP1: Plug the EG-SR-7100A module into the sockets on the test board.
Internet-bridge XPort
Ing. Z.Královský Ing. Petr Štol Perk 457 Okrajová 1356 675 22 STA 674 01 T EBÍ Development & production of control equipment Tel.: 568 870982 Tel.: 568 848179 Visualization, measurement and regulation
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version
Intel Do-It-Yourself Challenge Lab 2: Intel Galileo s Linux side Nicolas Vailliet
Intel Do-It-Yourself Challenge Lab 2: Intel Galileo s Linux side Nicolas Vailliet www.intel-software-academic-program.com [email protected] Intel Software 2014-02-01 Prerequisites and objectives
This document explains how to configure and use the IOPRINT+ Print Server in the Unix TCP/IP environment.
Unix - TCP/IP This document explains how to configure and use the IOPRINT+ Print Server in the Unix TCP/IP environment. Software Requirements TCP/IP protocol, FTP (Optional: - BOOTP, Rarp, Telnet) LPD
EMS. EtherCAN CI. Ethernet/CAN Interface. User Manual THOMAS WÜNSCHE. Documentation for Ethernet/CAN interface EtherCAN CI version 2.1.
Documentation for Ethernet/CAN interface version 2.1. Document version: V3.0 Documentation date: June 16th, 2007 This documentation is not valid for version 2.0 and earlier versions. No part of this document
PMOD Installation on Linux Systems
User's Guide PMOD Installation on Linux Systems Version 3.7 PMOD Technologies Linux Installation The installation for all types of PMOD systems starts with the software extraction from the installation
CP2110-EK CP2110 EVALUATION KIT USER S GUIDE. 1. Kit Contents. 2. Relevant Documentation. 3. Software Setup
CP2110 EVALUATION KIT USER S GUIDE 1. Kit Contents The CP2110 Evaluation Kit contains the following items: CP2110 Evaluation Board RS232 Serial Cable USB Cable DVD Quick Start Guide 2. Relevant Documentation
INSTALLING KAAZING WEBSOCKET GATEWAY - HTML5 EDITION ON AN AMAZON EC2 CLOUD SERVER
INSTALLING KAAZING WEBSOCKET GATEWAY - HTML5 EDITION ON AN AMAZON EC2 CLOUD SERVER A TECHNICAL WHITEPAPER Copyright 2012 Kaazing Corporation. All rights reserved. kaazing.com Executive Overview This document
How to Log On... 15 Main Screen... 18 Control Console Menus... 21. How to Log On... 24 Summary Page... 27 Navigation Menu... 29
Contents Introduction--1 Product Description.................................. 1 Access Procedures.................................... 3 How to Recover From a Lost Password..................... 6 Upgrading
EMG Ethernet Modbus Gateway User Manual
EMG Ethernet Modbus Gateway User Manual Rev 2.2 07/2010 CONTENTS 1. Introduction 1.1. General Features 1.2 Installing the Drivers 2. Configuration 2.1 Main Device Parameters 2.1.1 RS485 Serial Communication
How To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline
Application Note Last reviewed: 03/17/2008 AN-KEP-003.doc Page 1 of 23 Introduction... 1 Recommended s and ports to use... 1 Cable Wiring... 2 MDM-TEL Configuration ( Wizard)... 3 Direct Logic Communications
IP SERIAL DEVICE SERVER
IP SERIAL DEVICE SERVER ( 1 / 2 / 4 serial port ) Installation guide And User manual Version 1.0 1Introduction... 5 1.1Direct IP mode...5 1.2Virtual COM mode...5 1.3Paired mode...6 1.4Heart beat... 6
CNC File Transfer Box. Connecting the CNC File Transfer. CNC Transfer Program
CNC File Transfer Box The CNC File Transfer connects a serial CNC device to the network so files can be easily transferred from a computer to the CNC equipment. Any computer on the network can transfer
Quick Start Guide. Quick Start Guide. taskit GmbH. for Portux920T EU / SW Portux Mini-PC Portux Panel-PC Panel-Card MoLUX Stamp
Quick Start Guide for Portux920T EU / SW Portux Mini-PC Portux Panel-PC Panel-Card MoLUX Stamp Page 1 of 15 Version 1.14 Seelenbinderstr. 33 D-12555 Berlin Germany Tel. +49 (30) 611295-0 Fax +49 (30) 611295-10
Overview of ServerView Windows Agent This chapter explains overview of ServerView Windows Agent, and system requirements.
ServerView User s Guide (For Windows Agent) Areas Covered - Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview of ServerView
Easy Setup Guide 1&1 CLOUD SERVER. Creating Backups. for Linux
Easy Setup Guide 1&1 CLOUD SERVER Creating Backups for Linux Legal notice 1&1 Internet Inc. 701 Lee Road, Suite 300 Chesterbrook, PA 19087 USA www.1and1.com [email protected] August 2015 Copyright 2015 1&1
RSA Security Analytics. S4 Broker Setup Guide
RSA Security Analytics S4 Broker Setup Guide Copyright 2010-2013 RSA, the Security Division of EMC. All rights reserved. Trademarks RSA, the RSA Logo and EMC are either registered trademarks or trademarks
Network Attached Storage User Manual
http://www.icybox.de IB-NAS902 Network Attached Storage User Manual Content Content... 2 Introduction... 3 SMB... 3 FTP... 3 DHCP... 3 More than a NAS... 3 Package content... 4 Take a look at the IB-NAS902...
CYAN SECURE WEB HOWTO. NTLM Authentication
CYAN SECURE WEB HOWTO June 2008 Applies to: CYAN Secure Web 1.4 and above NTLM helps to transparently synchronize user names and passwords of an Active Directory Domain and use them for authentication.
Application Note 2. Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP.
Application Note 2 Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP. Reverse Telnet or Serial Terminal Server MultiTX feature UK Support March 2014 1 Contents
Project management integrated into Outlook
y Project management integrated into Outlook InLoox PM 7.x Help for the configuration for MySQL-Server An InLoox Whitepaper Published: October 2011 Copyright: InLoox GmbH 2011 You find up-to-date information
Version 0.1 June 2010. Xerox WorkCentre 7120 Fax over Internet Protocol (FoIP)
Version 0.1 June 2010 Xerox WorkCentre 7120 Fax over Internet Protocol (FoIP) Thank you for choosing the Xerox WorkCentre 7120. Table of Contents Introduction.........................................
isco Connecting Routers Back to Back Through the AUX P
isco Connecting Routers Back to Back Through the AUX P Table of Contents Connecting Routers Back to Back Through the AUX Ports...1 Introduction...1 Before You Begin...1 Conventions...1 Prerequisites...1
F2103 GPRS DTU USER MANUAL
F2103 GPRS DTU USER MANUAL Add:J1-J2,3rd Floor,No.44,GuanRi Road,SoftWare Park,XiaMen,China 1 Zip Code:361008 Contents Chapter 1 Brief Introduction of Product... 3 1.1 General... 3 1.2 Product Features...
USER S GUIDE Switched Rack PDU
Contents Introduction--1 Product Description....................................... 1 Access Procedures....................................... 3 Recover From a Lost Password..............................
Hands-on MESH Network Exercise Workbook
Hands-on MESH Network Exercise Workbook Santa Clara County RACES Date: 18 March 2015 Version: 1.0 scco_wifi_intro_exonly_v150318.docx 1 Table of Contents HANDS ON! Exercise #1: Looking at your Network
Command Line Interface User s Guide
Management Software AT-S85 and AT-S97 Command Line Interface User s Guide AT-MCF2000 Media Converter Series Version 2.0.0 613-000789 Rev. C Copyright 2008 Allied Telesis, Inc. All rights reserved. No part
LockView 4.3.1 CompX Database & Network Configuration & Installation Manual
LockView 4.3.1 CompX Database & Network Configuration & Installation Manual Table of Contents CompX Database & Network Configuration & Installation Manual Introduction... 4 Installation Requirements...
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
GV-Data Capture V3 Series User's Manual
GV-Data Capture V3 Series User's Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2006 GeoVision, Inc. All rights
Application Discovery Manager User s Guide vcenter Application Discovery Manager 6.2.1
Application Discovery Manager User s Guide vcenter Application Discovery Manager 6.2.1 This document supports the version of each product listed and supports all subsequent versions until the document
RMCS Installation Guide
RESTRICTED RIGHTS Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (C)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS
Product Manual. MDM On Premise Installation Version 8.1. Last Updated: 06/07/15
Product Manual MDM On Premise Installation Version 8.1 Last Updated: 06/07/15 Parallels IP Holdings GmbH Vordergasse 59 8200 Schaffhausen Switzerland Tel: + 41 52 632 0411 Fax: + 41 52 672 2010 www.parallels.com
Installation and Configuration Guide for Windows and Linux
Installation and Configuration Guide for Windows and Linux vcenter Operations Manager 5.7 This document supports the version of each product listed and supports all subsequent versions until the document
How To Set Up A Backupassist For An Raspberry Netbook With A Data Host On A Nsync Server On A Usb 2 (Qnap) On A Netbook (Qnet) On An Usb 2 On A Cdnap (
WHITEPAPER BackupAssist Version 5.1 www.backupassist.com Cortex I.T. Labs 2001-2008 2 Contents Introduction... 3 Hardware Setup Instructions... 3 QNAP TS-409... 3 Netgear ReadyNas NV+... 5 Drobo rev1...
Tool for Automated Provisioning System (TAPS) Version 1.2 (1027)
Tool for Automated Provisioning System (TAPS) Version 1.2 (1027) 2015 VoIP Integration Rev. July 24, 2015 Table of Contents Product Overview... 3 Application Requirements... 3 Cisco Unified Communications
HomeWorks P5 Processor Ethernet TCP / IP Networking Specification
HomeWorks P5 Processor Ethernet TCP / IP Networking Specification Table of Contents Table of Contents...2 Revision History...2 Overview...3 Single Ethernet Port...3 Protocols Used...3 TCP / IP Settings...3
LockView 4.2 CompX Database & Network Configuration & Installation Manual
LockView 4.2 CompX Database & Network Configuration & Installation Manual Table of Contents CompX Database & Network Configuration & Installation Manual Introduction... 4 Installation Requirements... 5
Expert Power Control NET 4x 8212 / 8213
2010 Gude Analog- und Digitalsysteme GmbH 2010 Gude Analog- und Digitalsysteme GmbH 23.08.2010 Content 3 Table of content Kapitel 1 Security Advise 5 Kapitel 2 Description 5 Kapitel 3 Hardware 6 3.1 Content
Router CLI Overview. CradlePoint, Inc.
Router CLI Overview CradlePoint, Inc. Preface CradlePoint reserves the right to revise this publication and to make changes in the content thereof without obligation to notify any person or organization
HP A-IMC Firewall Manager
HP A-IMC Firewall Manager Configuration Guide Part number: 5998-2267 Document version: 6PW101-20110805 Legal and notice information Copyright 2011 Hewlett-Packard Development Company, L.P. No part of this
Standalone recorder instruction
Standalone recorder instruction 1,Product profile... 2 2. Hardware interface... 2 2.1 2 &4 &8 channel standalone recorder front panel... 2 2.2 8&16 channel standalone recorder device interface... 3 3,
EXPRESSCLUSTER X for Windows Quick Start Guide for Microsoft SQL Server 2014. Version 1
EXPRESSCLUSTER X for Windows Quick Start Guide for Microsoft SQL Server 2014 Version 1 NEC EXPRESSCLUSTER X 3.x for Windows SQL Server 2014 Quick Start Guide Document Number ECX-MSSQL2014-QSG, Version
AN4128 Application note
Application note Demonstration board for Bluetooth module class 1 SBT2632C1A.AT2 Introduction This document describes the STEVAL-SPBT4ATV3 demonstration board (dongle) for the Bluetooth class 1 SPBT2632C1A.AT2
Debugging Network Communications. 1 Check the Network Cabling
Debugging Network Communications Situation: you have a computer and your NetBurner device on a network, but you cannot communicate between the two. This application note provides a set of debugging steps
Installation and Configuration Guide for Windows and Linux
Installation and Configuration Guide for Windows and Linux vcenter Operations Manager 5.0.3 This document supports the version of each product listed and supports all subsequent versions until the document
Environmental Management System
Contents Introduction--1 Product Description.................................. 1 Access Procedures................................... 3 How to Recover from a Lost Password..................... 6 Upgrading
Modbus Communications for PanelView Terminals
User Guide Modbus Communications for PanelView Terminals Introduction This document describes how to connect and configure communications for the Modbus versions of the PanelView terminals. This document
PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400
PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400 PePWave Surf Outdoor Series: Surf AP 200/400-X, PolePoint 400-X, Surf 400-DX User Manual Document Rev. 1.2 July 07 COPYRIGHT & TRADEMARKS
Library ModbusRTUlib Modbus RTU master communication. TXV 003 52.02 3 rd Issue February 2010 All rights reserved
R Library ModbusRTUlib Modbus RTU master communication TXV 003 52.02 3 rd Issue February 2010 All rights reserved History of changes Date Issue Description of changes April 2009 1 First issue of ModbusRTULib_V10
Volume. Instruction Manual
Volume 1 Instruction Manual Networking EVERFOCUS ELECTRONICS CORPORATION Networking Instruction Guide 2004 Everfocus Electronics Corp 2445 Huntington Drive Phone 626.844.8888 Fax 626.844.8838 All rights
IP Card Reader Interface User Manual
IP Card Reader Interface User Manual SB Research 2009-2011 The IP Reader Interface family: Concept: The IP Card Reader Interface allows access control card readers to be connected to a network device,
How Do I Recover infiniti Remotes and Line Cards?
How Do I Recover infiniti Remotes and Line Cards? Date: June 26, 2008 Overview This FAQ contains the following information and procedures pertaining to ids Release 6.0.1 and later: Before Attempting to
Master-Touch and ValuMass. Modbus Communications. INSTRUCTION MANUAL 80202201 (Rev. 2.1)
Master-Touch and ValuMass Modbus Communications INSTRUCTION MANUAL 80202201 (Rev. 2.1) Eldridge Products, Inc. 2700 Garden Road, Building A Monterey, CA 93940 Tel: 800/321-3569 or 831/648-7777 Fax: 831/648-7780
CS 326e F2002 Lab 1. Basic Network Setup & Ethereal Time: 2 hrs
CS 326e F2002 Lab 1. Basic Network Setup & Ethereal Time: 2 hrs Tasks: 1 (10 min) Verify that TCP/IP is installed on each of the computers 2 (10 min) Connect the computers together via a switch 3 (10 min)
Prestige 314 Read Me First
Prestige 314 Read Me First Console WAN 10M PORT Prestige Rear Panel Connections CONNECTION Use an RS-232 console cable. Use the cable that came with your broadband modem. LAN 10/100M Port Number COMPUTER
USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6
KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly
Integration Guide. Microsoft Active Directory Rights Management Services (AD RMS) Microsoft Windows Server 2008
Integration Guide Microsoft Active Directory Rights Management Services (AD RMS) Microsoft Windows Server 2008 Integration Guide: Microsoft Active Directory Rights Management Services (AD RMS) Imprint
