COMPACT & SPLIT - QUATTRO AIR-CONDITIONERS QUATTRO
|
|
|
- Silvester Roberts
- 9 years ago
- Views:
Transcription
1 COMPACT & SPLIT - QUATTRO AIR-CONDITIONERS COMPACT end SPLIT QUATTRO models INSTALLATION MANUAL USE & SCHEMATICS COMPACT QUATTRO SPLIT QUATTRO Cod. A /9/06 S.p.A. COMPANY WITH QUALITY SYSTEM CERTIFIED BY DNV ISO 9001/2000 Via Cantore, 6/ Giussano (MI) ITALY Tel fax [email protected]
2 1.1 - CRATING The CLIMMA air-conditioning unit is fastened to a wood plane and crated. Pay attention at opening. Unhook the unit, unscrewing the provided clamps. Keep them to fasten the unit on the boat. Raise the unit using the rope handles provided for this purpose. Don t raise it getting hold of fans and pipes, that can suffer damage. On the unit there is a label that describes its technical specifications. NOTE Check that the technical specifications, the electrical supply, etc... on the label correspond to the technical specifications of the boat. EXAMPLE OF LABEL page 2
3 2.1 Installation diagram of the Compact air-conditioner Electrical heating (EH) version ) Electrical box 05) Electrical supply 06) Air inlet grill 07) Air filter 08) Remote control panel 09) Insulating flexible duct 10) Air outlet plenum 11) Air outlet grill 12) Condensation drainpipe 13) Sea water inlet pipe 14) Sea water pump 15) Sea water intake valve 16) Sea water filter 17) Sea water intake 18) Thermostat bulb 19) Air-conditioner 20) Sea water drainpipes page 3
4 2.2 Installation diagram of the Split air-conditioner with EV Electrical heating (EH) version ) EV exchanger 02) Split compressor 03) Connecting pipes for refrigerant 04) Electrical box 05) Electrical supply 06) Air inlet grill 07) Air filter 08) Control panel 09) Insulating flexible duct 10) Air outlet plenum 11) Air outlet grill 12) Condensation drainpipe 13) Sea water outlet pipe 14) Sea water pump 15) Sea water intake valve 16) Sea water filter 17) Sea water intake 18) Thermostat bulb 19) Air-conditioner 20) Sea water drainpipes 17 page 4
5 3 INSTALLATION O F THE COMPONENTS FUNCTIONING OF THE AIR-CONDITIONERS During the cooling cycle, the refrigerant circuit takes the ambient air away and to make it over the sea water (CO models). It is possible to select the functioning cycle, the desired temperature and the fan speed from a remote control panel that can be installed in the airconditioned room. For the specific distances, refer to the directions of the remote control panel (page 149). Version with standard mechanical panel ARRANGEMENT - General notes Choosing the unit position, it is necessary to consider the following elements: 1 - the accessibility to the air filter for the cleaning; 2 - the necessary space for the fastening of the provided clamps (figure page 8); 3 - the connection of the condensation drainpipes (figure page 8); 4 - since the fan rotates, it is necessary to choose the best position to connect it to the air duct. Then, block the fan in the chosen position; 5 - the passing of the sea water circuit pipes; 6 - the passing of the electrical connection wires and the easy access to the electrical box. Position the pipe-tightening clamps of the water system so that once arranged the unit, it is possible to tighten the screws. Instead of the clamps we suggest to use all stainless steel components. page 5
6 3 INSTALLATION O F THE COMPONENTS PLACING A.- The unit has been designed to take the ambient air directly away. It must be installed in a room that must be conditioned. B.- The conditioned air (from the fan) must be piped towards one or more grills through flexible pipes or through isolated ducts of suitable section in the boat structure. C - The exchanger system takes away the ambient air. The side with the filter mustn t be in line with the aspiration grill, as in the picture 1.6. It can have have also a different position (see the picture 2.6). The second solution is the best one thanks to the best sound isolation of the system. View from above Figure 1.6 View from above Figure 2.6 page 6
7 3 INSTALLATION O F THE COMPONENTS E.- The air-conditioner is connected to the electrical box through cables of different lenght. So there must be an accessible space (next to the compressor unit for SPLIT models) to install the electrical box. F.- The thermostat bulb and the aspiration filter must be mounted on the air-refrigerating gas exchanger. This side must be accessible for the filter maintenance. G.- The maximum distance between the control panel and the electrical box is 3 m both for the thermostat capillary and for the connection cable THERMOSTAT BULB The thermostat bulb must be fastened to the air exchanger by means of special latches. The bulb must keep separated from the exchanger because it must be influenced only by the sucked up air, but not by the refrigerating circuit. Sometimes you can install the bulb not directly on the exchanger but in the room, so that it is sensitive to the ambient temperature. To fasten the bulb to the wall, you can use the special plaque. page 7
8 3 INSTALLATION O F THE COMPONENTS FASTENING The fastening must be executed as indicated. Figure 1.8 NEOPRENE CONDENSATION OUTLET The air-conditioning determines the separation of the condensation water due to the humidity of the conditioned air. This condensation must be discharged in the bilge or in a special tank and then by means of a self-priming pump in the sea. The direct bulkwark outlet is not the best solution: in fact, it can suck up unpleasant smells due to the exhaust emissions of its own or of other engines. Make reference to the safety regulations of the different countries Dis 2.8 Each unit is endowed with two outlets, as you can see in the picture above. The water condensation outlet pipe must be linked to the rubberholders of 19 mm on the condensation collection basin. If the condensation discharge pipe for exigencies of installation must be long, it is better to use the special L connection. You must avoid such an installation as you can see in the picture 1.8 because the condensation water can stop and flow back to the collection basin because of the boat rocking. Figure 2.8 page 8
9 3 INSTALLATION O F THE COMPONENTS CONDENSATION OUTLET Since during the operating the air-conditioner sucks up and causes a light vacuum in the room, the condensation outlet pipe can suck up from the pilge or the special tank unpleasant smells that can spread in the cabin. To avoid this possibility, it is possible to create a siphon (A) as you can see in the picture 1.9 to stop the air. A A Figure 1.9 To check the actual efficiency of the condensation outlet, pour some water in the basin AIR FILTER The air-conditioner sucks up the ambient air through an air-refrigerating gas exchanger endowed with many aluminium tongues. They would soon become obstructed because of powder and filth. That s why you can mount the air filter directly on the exchanger (as you can see in the picture). The filter must be easily taken off to clean or replace it. page 9
10 3 INSTALLATION O F THE COMPONENTS 3.9- AIR CIRCULATION SYSTEM (see examples on page 12) 3.9.A - Sucking up View from above min 244 x 244 Viiew from above The ambient air is sucked up through one or more grills of suitable dimensions. The minimum dimensions are 244x244. (To canalize the air flow back, call the technical assistance) B - Air circulation The efficiency of the installation depends on the air volume. So it is important to avoid narrow passages in the air circulation system, keeping the original diameter dimensions and using short pipes B - Air ducts The isolated ducts must not be bent so that the air can circulate currently. Cut out the unuseful lenght. page 10
11 3 INSTALLATION O F THE COMPONENTS 3.12.C - COMPACT - SPLIT QUATTRO The fan must be linked by means of a duct to the air distribution system, that can be constituted of one or more grills and corresponding plenums. The main duct diameter must not be inferior to the diameter of the fan fittings. The fan can be turned of 90 in case of installation of limited height. Example of a Compact installation: a plenum for air-conditioning two cabins. page 11
12 3 INSTALLATION O F THE COMPONENTS AIR DISTRIBUTION LAYOUT EXEMPLE DE DISTRIBUTION D AIR ESEMPI DI DISTRIBUZIONE ARIA ONE OUTLET - UNE SORTIE SEULEMENT - UNA SOLA USCITA A A L1 5 Btu/h 2 L1 A 1 2 L1 A x x x x L1 5 TWO OUTLET - DEUX SORTIES - DUE USCITE A 5 A B 4 B L1 L2 L1 L2 Btu/h 2 L1 A 4 L2 B x x x x x x x x112 1 = Air-conditioning unit - Unitè de climatisation - Unità condizionatore 2 = Main air duct - Gaine d air principal - Condotta d aria principale 3 = Air splitter plenum - Plenum distribution air - Plenum di divisione aria 4 = Secondary air duct - Gaine d aire secondaire - Condotta aria secondaria 5 = Air plenum - Plenum grille - Plenum per griglia 6 = Air plenum - Plenum grille - Plenum per griglia A = Main air delivery grill - Grille distribution principale - Griglia di mandata aria principale B = Secondary air delivery grill - Grille distribution secondaire - Griglia di mandata aria secondaria R min=1.5 D DUCT SPECIFICATIONS - SPECIFICATION DU GAINE - SPECIFICHE DELLA CONDOTTA 1 = SUGGESTED - CONSEILLE - SUGGERITO 2 = ACCEPTED - ACCEPTE - ACCETTATO 3 = WRONG - DECONSEILLE - SCONSIGLIATO R1-R2 min= 2D C331 05/96 page 12
13 ELECTRICAL BOX It contains the following electrical connections: - to the grid; - to the compressor-fan-checks group; - to the control panel; - to the sea water electrical pump; - to the external temperature probe. 2 INSTALLATION O F THE COMPONENTS 3.13.A - PLACING You can install the electrical box in any position. A You must install the electrical box near the air-conditioning unit, to which it is connected by means of a 2 m cable. It must be easily accessible for the maintenance or repair. Fasten the inlet cables with the suitable terminal (A). You must fasten the electrical box on the wall by means of four screws, using the holes provided in the base. page 13
14 3 INSTALLATION O F THE COMPONENTS MECHANICAL CONTROL PANEL By means of the control panel, you can set and control the following functions: 2.11.A - PLACING You must choose the correct position to connect the panel to the board by means of a 3 m cable (included) and to install the thermostat bulb on the unit exchanger. If necessary, you can install the bulb not directly on the exchanger but in the room, choosing the right position to control the temperature. To fasten the bulb on the wall, you can use the suitable plaque. A.-Switching on and off SUMMER AIR-CONDITIONING : push the COOL button with the ice star. WINTER HEATING : push the HEAT button with the orange sun. To switch off, put the switch in the central position. B.- Setting-regulation of the temperature by means of the thermostat (TEMP). The thermostat has got a 3 m capillary with a bulb. The bulb must perceive the sucked up air (it must not come into contact with the exchanger tongues; it is in fact the battery where the refrigerant spreads: the tongues cool down, so that if the bulb comes into contact with them, it will perceive a temperature value that is lower than the ambient temperature). C.- Regulation of the fan speed: by means of the button with the fan it is possible to regulate the four fan speeds. Push the button to select the fan speed: upwards arrow means speed increase and downwards arrow means speed decrease. Switching on the fan for the first time, it will run in MED speed. Then it will run according to the last selected speed B.- INTERCHANGEABLE PLAQUE The standard plaque (included) is black C - FASTENING The panel has been designed for a casing fastening. You must drill into it as indicated on the right. IMPORTANT NOTE : In the panel there is only low voltage. After having installed it, the back must not be accessible. An optional protection cover (code: M69330) is available. If the panel back is accessible because it may suffer damages DIGITAL CONTROL PANEL VEGA MKII (optional) For the technical specifications and for the installation directions, make reference to the manual VEGA MKII (code: A52000). page 14
15 3.INSTALLATION O F THE COMPONENTS PRE-CHARGED GAS PIPES WITH RAPID COUPLINGS (only for SPLIT models) SPLIT QUATTRO air-conditioners are composed by the compressor unit and by the evaporator. SPLIT 4 QUATTRO and SPLT 8 QUATTRO are pre-charged with R134A and endowed with rapid couplings. The refrigerant gas circulates between them through pre-charged copper pipes with rapid couplings for the connection. The standard pipe connected to the evaporator is 70 cm long. It is possible to separate two units by means of extension leads of different lenght. During the connectiuon, observe the instructions of labels on two sides: Compressor side and Evaporator side according to the following outlet. Handle pipes carefully to avoid breakages due to incorrect use. The least bending radius is 50 mm CONNECTING PIPES Except SPLIT 4 QUATTRO and SPLIT 8 QUATTRO models, all other models of SPLIT QUATTRO range are not pre-charged.the connection between two units is a FLARE type connection. So only qualified personnel must carry out the discharge and the charge of the system. It s not VECO S.p.a. but the installer to provide the material for this operation. The flare must be perfect (without any burr or imperfection). The lenght of the flare walls must be the same. OUTLET AND INLET PIPES SECTIONS For the section of outlet and inlet pipes, it is necessary to follow carefully the instructions on each SPLIT QUATTRO unit. page 15
16 4 SEA W ATER CIRCUIT SEA WATER ELECTRICAL PUMP Thanks to the sea water electrical pump the water volume indicated in the exchanger can circulate. The electrical pump must be noiseless. It must work continually and it must be produced with marine building materials PLACING A B STERN BOW Install the electrical pump horizontally. Its vertical outlet opening must be upwards and at least 50 cm below the water line. Sea water blade intake towards the bow C D MAX 1 mt The filter and the connection to the electrical pump must be linked without any siphon (vertically from the sea water intake to the electrical pump intake). The section of the intake pump must be as short as possible (less than 1 m for an efficient circuit) FASTENING Fasten the electrical pump by means of the suitable screws using the holes provided in the base. The flexible installation (with anti-vibrating system) makes the electrical pump more noiseless. page 16
17 4.4- SEA W ATE R CIRCUIT 4 SEA W ATER CIRCUIT The circuit follows a vertical line from the sea water intake to the unit exchanger. Then it can follow both a vertical or an horizontal direction. Anyway it is better not to create any siphon, because some air bubbles coming from the sea water intake during the sailing may remain in the circuit. The water jet of the discharge must not disturb either the guests of the boat where it is installed or the ones of the other boats. LWL page 17
18 4 SEA W ATER CIRCUIT ELECTRICAL CONNECTIONS All electrical pumps are single-phase pumps. So they need a connection to the neutral wire, to the phase and to the grounding. Check always that the voltage on the label corresponds to the voltage available on board. Execute the connection according to the diagram on the terminal board cover. Follow the sequence of the phases for the pump connection. Check that the rotation direction corresponds to the instructions of the pump SELF-PRIMING ELECTRICAL PUMP If it is not possible to follow the instructions at 3.2, it is necessary to install a self-priming electrical pump following the same instructions for the connection of a centrifugal pump. Before starting it, it is necessary to fill the electrical pump tank to make it self-priming. page 18
19 CONDIZIONATORI Modelli COMPACT e SPLIT - QUATTRO 5 ELECTRICAL CIRCUIT WARNING AVOID THE RISK OF THE ELECTROCUTION!!! Only the qualified staff can execute the troubleshooting and the repair. Keep isolated from the ground during the execution of the electrical operations, wearing dry clothes, rubber shoes, rubber carpets, etc... Don t check wires under voltage if none can bring help. IMPORTANT NOTE To avoid possible electrical shocks, that can cause harm or death to people, execute the grounding of the airconditioning system, as indicated: 1- Use a suitable electrical cable with ground wire section and isolation to give the charge from the switch on the control board of the boat to the electrical box of the system. The ground wire must be correctly connected to the ground terminal of the panel. 2- Check that the ground connection between the electrical box and the air-conditioner hasn t suffer any damage during the transport. 3- Check that the connection of the water pump to the suitable terminal of the electrical box includes also the ground connection. 4- Check the ground continuity before switching off the air-conditioner. pag. 19
20 5 ELECTRICAL CIRCUIT ELECTRICAL BOX The COMPACT & SPLIT QUATTRO air-conditioners are available in the CO configuration (Cooling Only) SUPPLY Check that the available supply corresponds to the label on the unit, on the box and on the electrical pump. A bipolar switch with suitable fuses supplies the connection board of every unit. The supply cables must be proportionated to the charge. The supply must be connected to the terminal board, for which section wires up to 4 mm are suitable. Fasten the cable using the suitable clamps. page 20
21 5 ELECTRICAL CIRCUIT 5 - FUNCTIONS OF THE BOARD ADJUSTABLE DELAY FUNCTIONS OF THE BOARD / CAPTION Paragraph Page 1 ADJUSTABLE DELAY BOARD SETTING POWER FUSE FUNCTIONING WARNING LIGHTS SELECTOR FOR MULTIPLE INSTALLATIONS When more groups are connected to the same grid and are supplied simultaneously, it is necessary to activate the delay function: you must turn its device clockwise as indicated in the figure. You can regulate the delay from 2 to 12 seconds. Figure 1 Detail of the delay device (detail 1 of the figure 1). NOTE : It is necessary to differentiate the switching on delays of different air-conditioners at least of 4 seconds one from another. page 21
22 5 EKLECTRICAL CIRCUIT 5 - FUNCTIONS OF THE BOARD BOARD SETTING FUNCTIONS OF THE BOARD / CAPTION Paragraph Page 1 ADJUSTABLE DELAY BOARD SETTING POWER FUSE FUNCTIONING WARNING LIGHTS SELECTOR FOR MULTIPLE INSTALLATIONS Detail of the setting device (detail 2 of the figure 1). Figure 1 SWITCH The board connected to the group has already been set. Set only replacement material or when you exchange boards and groups. page 22
23 5 ELECTRICAL CIRCUIT 5 - FUNCTIONS OF THE BOARD POWER FUSE FUNCTIONS OF THE BOARD / CAPTION Paragraph Page 1 ADJUSTABLE DELAY BOARD SETTING POWER FUSE FUNCTIONING WARNING LIGHTS SELECTOR FOR MULTIPLE INSTALLATIONS Detail of the power fuse and of its casing (detail 3 of the figure 1). Figure 1 A power fuse is included in the board. For the value, make reference to the value. page 23
24 5 E LECTRICAL CIRCUIT 5 - FUNCTIONS OF THE BOARD FUNCTIONING WARNING LIGHTS FUNCTIONS OF THE BOARD / CAPTION Paragraph Page 1 ADJUSTABLE DELAY BOARD SETTING POWER FUSE FUNCTIONING WARNING LIGHTS SELECTOR FOR MULTIPLE INSTALLATIONS Figure 1 On the board there are some functioning warning lights. The following outline shows their functions. A B C D E F G HP LED LED ON WHEN POWERBOARD SET MASTER POWER ON LED ALLARME POMPA?????????????? The figure shows the position of the functioning warning lights (detail 4 of the figure 1). page 24
25 CONDIZIONATORI Modelli COMPACT e SPLIT - QUATTRO 5 ELECTRICAL CIRCUIT 5 - FUNCTIONS OF THE BOARD SELECTOR FOR MULTIPLE INSTALLATIONS FUNCTIONS OF THE BOARD / CAPTION Paragraph Page 1 ADJUSTABLE DELAY BOARD SETTING POWER FUSE FUNCTIONING WARNING LIGHTS SELECTOR FOR MULTIPLE INSTALLATION It is possible to connect two or more systems to the same control panel. In this case it is necessary to act on the selector (5) as indicated in the following outline. ATTENTION INCORRECT SETTING PREVENTS COMPACT AND SPLIT UNITS TO WORK BECAUSE OF A PROTECTION (SEE TROUBLESHOOTING ). The figure shows the selector (detail 5 of the figure 1). Figure 1 Set MASTER (MA) when remote panel is connetted to the powerboard (default). Set SLAVE (SL) when powerboard is in multiboard configuration but remote panel is not connected. pag. 25
26 5 ELECTRICAL CIRCUIT CONNECTIONS TO THE BOARD CONNECTIONS 1c 2c 3c 4c 5c 6c 7c 8c 9c 10c 11c 12c 13c ROOM PROBE -OPTIONAL- BRIDGE DIGITAL PANEL MECHANICAL PANEL PUMP MAIN SUPPLY HP PRESSURE SWITCH SENSOR NTC -OPTIONAL- REV. VALVE OR 1ST. HEATER 2ND. HEATER FAN COMPRESSOR CONNECTION FOR RS485 page 26
27 CONDIZIONATORI Modelli COMPACT e SPLIT QUATTRO 5 ELECTRICAL CIRCUIT MULTIPLE INSTALLATION The CABIN air-conditioner fits perfectly in multiple installations. These are the features of a multiple installation: - more systems are supplied by the same sea water electrical pump; -the compressor of each system must start with a certain delay CONNECTION TO THE PUMP FOR MULTIPLE INSTALLATIONS It is available the relay box for the pump as optional. Each air-conditioner is connected to the realis box. The supply of the pump and of the air-conditioners must not be the same. The first one must be protected by an indipendent fuse. The pump must be supplied by all relays connected to each box. pag. 27
28 CONDIZIONATORI Modelli COMPACT e SPLIT QUATTRO 6 GOOD FUNCTIONING CHECK CHECK OF THE SEA WATER ELECTRICAL PUMP 1.- Put the thermostat knob on "24" (clockwise). 2.- Push the "COOL" button. 3.- Check that the electrical pump turns regularly and that the water flow is regular and corresponding to the specifications of the installation. The fan runs at the selected speed CHECK OF THE COOLING CYCLE Air-conditioner as indicated in 5.1: 1.- Turn slowly the thermostat (TEMP) anticlockwise towards 18 until the copressor starts running. 2.- Check that after few seconds the air coming from the distribution plate cools down perceptibly. If the airconditioner runs for some time, it is possible to check the functioning of the thermostat and the condensation outlet system. If it is damp, the exchanger will get wet and start drop forming the condensation, that must drain outboard. 6.3.A- CCHECK OF THE HEATING CYCLE (CYCLE REVERSAL) Air-conditioner off. Put the thermostat on 24. Put the FAN knob on MAX and push the HEAT button. Check that after few seconds the air coming out from the distribution plate warms up. If the air-conditioner runs for some time, it is possible to check the functioning of the thermostat. 6.3.B- CHECK OF THE HEATING CYCLE ( ELECTRICAL HEATING) Air-conditioner off. Put the thermostat on 24 ; put the FAN knob on MIN and push the HEAT button. Check that after few seconds the air coming out from the distribution plate warms up. If the air-conditioner runs for some time, it is possible to check the functioning of the air-conditioner. NOTE: Because of the electrical heating the compressor and the sea water pump don t work. The air coming out will be warmer if the fan speed is the lowest CHECK OF THE SEA WATER CIRCUIT During the running, it is very important to check the tightness of all the fittings below the water line. Check the flow at the outlet or by a liter-counter CHECK OF THE ELECTRICAL PUMP ABSORPTION Since technical specifications of cooling circuits are always different, it is necessary to check that the electrical pump runs by its parameters. During the functioning, measure the electrical pump absorption by means of an ammeter. The absorption must not exceed the value on the label of the electrical pump. In this case, switch off the air-conditioner and check the circuit (see 3.7) CHECK AND CALIBRATION OF THE AIR CIRCUIT DISTRIBUTION It is very important to measure and regulate the conditioned air volume. On this depends the efficiency of the system during its running in sailing. It is not necessary to switch on the compressor, but only the fan group. It is possible to execute this operation even in shipyard supplying the air-conditioner by means of the ground voltage. To obtain the hole capacity of the system, you must measure the conditioned air volume on the inlet grill of the system by means of an ammeter. SEee the following page pag. 28
29 CONDIZIONATORI Modelli COMPACT e SPLIT QUATTRO 6 GOOD FUNCTIONING CHECK MEASURING OF THE AIR VOLUME Follow these instructions: 1.- Measure the net surface in mt2 of the inlet grill without the frame. 2.- Measure the air speed on different points of the grill. 3.- Add up the different speed values and divide them by the number of measurements to obtain the air speed average (in mt/s or mt/m according to the measuring instrument). 4.- Thanks to one of the following formulas it is possible to draw the air volume in the system: V = SxSx3600 V = SxSx60 Where: V = mt3/h of conditioned air S = surface in mt2 of the grill without the frame S = air speed in mt/s or mt/m 3600 = for the speed in mt/s. 60 = for the speed in mt/m From these formulas it is possible to draw the following ones: Compare the volume in mt/3/h with the value indicated in the table of technical specifications. If the air volume is lower of 15/20% than values in the table (but not more than 15/20%), the value can be considered normal. The measurement on the outlet grill can be useful for the balancing if there are more outlet grills for a comparaison with the air volume of the outlet grill. To air-condition two or more cabins, it is necessary to calculate the air volume to introduce. To obtain this value, divide the air volume obtained from the previous measurement by all air-conditioned mt3 (ratio between conditioned air and conditioned volume). Multiply this value by volumes of each cabin to obtain a rough value of the conditioned air to introduce. Example: pag. 29
30 78/9 USE DIRECTIONS FUNCTIONING OF THE COMPACT & SPLIT QUATTRO AIR-CONDITIONERS During the cooling cycle the refrigerating circuit takes the heat away from the ambient air and makes it over to the sea water. On the contrary, in the heating cycle an electrical resistance, controlled by the ambient thermostat, generates the heat (EH version with electrical heating). There is also a second version of the COMPACT & SPLIT QUATTRO air-conditioners with inversion cycle instead of the electrical heating. For the RC models with reversal cycle the heat is taken away from the sea water, that cools down and made over to the air, that warms up. The heat pump (heating) is the best solution if the sea water temperature is above 10 C. You can select the functioning cycle, the desired temperature and the fan speed by means of the control panel, installed in the air-conditioned room and controlling the ambient temperature (only the mechanical panel has got the thermostat with the capillary. In fact, for the digital one, the sensor is in the panel) MECHANICAL CONTROL PANEL By means of the control panel, you can set and control the following functions: A.-Switching on and off SUMMER AIR-CONDITIONING : push the COOL button with the ice star. WINTER HEATING : push the HEAT button with the orange sun. To switch off, put the switch in the central position. B.- Setting-regulation of the temperature by means of the thermostat (TEMP). The thermostat has got a 3 m capillary with a bulb. The bulb must perceive the sucked up air (it must not come into contact with the exchanger tongues; it is in fact the battery where the refrigerant spreads: the tongues cool down, so that if the bulb comes into contact with them, it will perceive a temperature value that is lower than the ambient temperature). C.- Regulation of the fan speed: by means of the button with the fan it is possible to regulate the four fan speeds. Push the button to select the fan speed: upwards arrow means speed increase and downwards arrow means speed decrease. Switching on the fan for the first time, it will run in MED speed. Then it will run according to the last selected speed SUMMER FUNCTIONING (COOLING) BY MEANS OF THE MECHANICAL CONTROL PANEL Switch on the system, pushing the COOL button. Turn the thermostat knob towards - anticlockwise, until the compressor starts running. Pushing the Fan button regulate the fan speed until the desired speed MIN- MED-MAX-EXTRA-MAX. When in the cabin there is the desired temperature, turn the thermostat knob towards + clockwise until the compressor stops running. After having switched off the compressor, the fan makes the air circulate without cooling it down until the compressor starts running again WINTER FUNCTIONING BY MEANS OF THE MECHANICAL CONTROL PANEL (HEATING BY MEANS OF THE ELECTRICAL RESISTANCE - EH MODEL) Switch on the system, selecting HEAT. Turn the thermostat knob towards +. After few seconds the warm air will come out. Select the desired fan speed. Let the air-conditioner run until in the room there is the ideal temperature. Then turn the thermostat knob towards - anticlockwise until the resistance stops. As indicated in 2.1, switching off the resistance, the air-conditioner makes the air circulate without warming it up. In case of fan breakdown or obstruction of the air outlet, an internal safety device switches off the resistance to avoid the overheating. To reset the normal functioning, switch off the system pushing the COOL-OFF-HEAT button, solve the problem causing the block, wait for some minutes and switch on again the air-conditioner. In systems with electrical heating, during the functioning in Heat mode, the compressor and the pump don t run WINTER FUNCTIONING BY MEANS OF THE MECHANICAL CONTROL PANEL (HEATING BY MEANS OF THE REVERSAL CYCLE - RC MODEL) Switch on the system selecting HEAT. Turn the thermostat knob towards + until the compressor starts running. Select the fan speed. When in the cabin there is the desired temperature, turn the thermostat knob towards - anticlockwise until the compressor stops. As indicated in 2.2, switching off the compressor, the airconditioner makes the ambient air circulate without warming it up. If the sea water temperature is above 18 page 30
31 7/8/9 USE DIRECTIONS C, the high pressure safety device will snap. Switch off the system and then switch it on again and select a higher fan speed value. 8 - IMPORTANT NOTES INSTALLATION IN THE ENGINE COMPARTMENT (only for SPLIT models) The air-conditioner use can cause the going off of sparks (switches, relays, etc...) To avoid the risk of explosions, it is necessary to start the smoke-exhauster 10 minutes before switching on the air-conditioning system and they must suck up the smoke as long as the air-conditioner runs TROUBLESHOOTING Only the qualified staff can execute the troubleshooting respecting the safety regulations MULTIPLE INSTALLATION It is necessary to space out the switching on delays of the air-conditioners at least of 5 seconds one from another. 9 - MAINTENANCE For an efficient functioning of the air-conditioner, follow these advices about checks and maintenance. Intervention times can change according to the installation place, the pollution and the installation use. " Clean the sea water filter every week. " Clean the air filter every month. " Clean the condensation outlet pipe every four months. " Clean the condensation collection tray every year. " Clean the water intake every year (operation to be executed in shipyard). " Change the batteries (only for Vega MK II with remote control device) every year. These operations must be executed only after having switched off the air-conditioner and only by the qualified staff. Don t check the electrical circuit if none can bring help in case of accident. " Check hydraulic connections every year. " Consult also Installation Manual CONDENSATION WATER AND ITS OUTLET During the cooling cycle air-conditioners produce much condensation water, above all when it is damp. Check periodically that there are no leaks or obstructions on the condensation outlet and that the condensation water drains regularely. Pour in the condensation tray some water and check that it flows currently. If the condensation water drains to the bilge, it is better to let it flow towards a limited space and let it drain continually to avoid stagnation that can cause unpleasant smells AIR FILTER The filter on the exchanger air outlet must be periodically cleaned and/or substituted. This filter avoids the obstruction of the air-conditioner exchanger. The maintenance frequency depends on the running hours number and above all on the air pollution. We suggest to clean the filter every month. An obstructed air filter can cause a decrease of the system efficiency in cooling mode (COOL). In the heating cycle (RC models) in system with reversal cycle, it can block the system because of the high pressure; in EH models with electrical resistance it can block the system because of the intervention of an internal safety device SEA WATER FILTER (for the COMPACT models there is a water circuit) The water filter on the intake of the cooling water electrical pump must be periodically cleaned. Thanks to this filter the pump and the cooling circuit work correctly. The maintenance frequency depends on the running page 31
32 7/8/9 ISTRUZIONI PER L USO hours number of the system and above all on the water pollution. We suggest to check the sea water filter every week. To check that there are no obstructions, check the pump outboard discharge (N). If there is a lack of circulating water in the cooling cycle, the efficiency of the system decreases and the air-conditioner may get stuck. In the heating cycle, in RC models it can decrease the system efficiency COLD If you don t use the boat and the temperature is below 0 C, you must drain the water in the condenser, in the electrical pump, in the filter and in the connection pipes. You must: - close the sea water intake; - take off the pipe of the water intake on the condenser (between the electrical pump and the air-conditioner) to drain the condenser water; - clean the filter and drain the water in the filter and in the electrical pump. page 32
33 10. TROUBLESHOOTING A N D REPAIR IDENTIFICATION OF THE PRODUCT Each product is identified by means of a label. Make reference to the description, to the code, to the series number if you must eventually call the Assistance Centre TROUBLESHOOTING Before calling an Assistance Centre, check the system. The following problems are the most common ones and you can solve them. If the system doesn t work, even after having checked it, call the nearest CLIMMA Assistance Centre. Call the Veco Service: or consult the WEB page: THE UNIT DOESN T WORK Is the automatic switch snapped? Reset the switch on the main board. (Is the supply voltage too low? Check the voltage value between L and N of the MAIN POWER terminal on board.) THE FAN DOESN T TURN Is the air-conditioner switched on? Switch on the unit by means of the control panel. Is the fuse burned? After the necessary checks, replace the F1 fuse with another one with the same dimensions and charge THE COOLING IS NOT SUFFICIENT - CO, RC, EH VERSIONS Have you selected the correct operational mode? Select on the panel the cooling mode (COOL) or AUTO (only for the digital model). Have you correctly regulated the thermostat? Regulate the temperature on lower values. Is the fan speed too low? Increase the fan speed or select the AUTO mode for the digital version. Is the air circulation insufficient? Check that there are no obstructions on the outlet or inlet grills and that the filter is cleaned. Is the air filter dirty? Clean or replace it. Has the compressor been running only for short periods? The high pressure switch device is snapped. Check the water circulation, the filter and the sea water pump. Doesn t the compressor run? The high pressure switch device is snapped more than three times. Check the sea water circuit, switch off and then switch on again the system by means of the panel. If this happens again, call the Assistance Service THE HEATING IS NOT SUFFICIENT - EH VER- SION Have you selected the correct operational mode? Select on the panel the heating mode (HEAT) or AUTO (only for the digital model). Have you correctly regulated the thermostat? Regulate the temperature on higher values. Is the fan speed too high? Decrease the fan speed or select the AUTO mode for the digital version. Is the air circulation insufficient? Check that there are no obstructions on the outlet and inlet grills and that the air filter is cleaned. Is the air filter dirty? Clean or replace it. Has the heating been working only for few minutes? The resistance protection device is snapped. Check the air circulation, the fan speed and the air filter. If this happens again, call the Assistance Service THE HEATING IS NOT SUFFICIENT - RC VER- SION Have you selected the correct operational mode? Select on the control panel the heating mode (HEAT) or AUTO (only for the digital model). Have you correctly regulated the thermostat? Regulate the temperature on higher values. Is the fan speed too high? Decrease the fan speed or select the AUTO mode for the digital version. Is the air circulation insufficient? Check that there are no obstructions on the outlet and inlet grills and that the air filter is cleaned. Has the compressor been running only for short periods? The high pressure switch device is snapped. Check the air circulation and that there are no obstructions on the openings and on the inlet grill and that the filter is cleaned. Is the air filter dirty? Clean or replace the filter. Doen t the compressor run? The high pressure switch device is snapped more than three times. Check the air circulation. Switch off and then switch on again the system by means of the panel. If this happens again, call the Assistance Service THE SEA WATER PUMP DOESN T WORK Is the fuse burned? After the necessary checks, replace the F1 fuse with another one with the same dimensions and charge. Is the high pressure switch device snapped? Check the cooling circuit and clean the filter on the sea water intake. If this happens again, call the Assistance Service. page 33
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
INSTALLATION MANUAL Climma Compact Units
COMPACT & SPLIT - QUATTRO INSTALLATION MANUAL Climma Compact Units Cod. A52040NA July 1 2009 Ver. 1 18 - marzo - 2008 AIR-CONDITIONERS 1.1 - The CLIMMA air-conditioning unit is fastened to a wood base.
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
Important Safeguards
Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
PORTABLE AIR CONDITIONER
PORTABLE AIR CONDITIONER MAC 7500 Owner s Manual Air Conditioner Dehumidifier Oscillating Fan Please read this owner s manual carefully before operating the unit. POWERED BY 66126113.p65 17 INTRODUCTION
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA
USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
SWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
WINDOW ROOM AIR CONDITIONER
WINDOW ROOM AIR CONDITIONER Installation and Operation Manual Electromechanical Remote Control CAPACITIES 220V - 60 HZ. 12,000; 18,000; 24000 BTU/HR 220V-240V - 50 HZ. 12,000; 18,000; 24000 BTU/HR Please
SERVICE MANUAL REFRIGERATION
SERVICE MANUAL REFRIGERATION ELECTROLUX ZANUSSI S.p.A. Publication no. Spares Operations Italy 599 35 61-04 Corso Lino Zanussi, 30 021218 I - 33080 PORCIA / PN (ITALY) ITZ/SERVICE/AA Fax +39 0434 394096
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
CENTRAL AIR CONDITIONER SPLIT SYSTEM
CENTRAL AIR CONDITIONER SPLIT SYSTEM WITH ELECTRONIC CONTROL SERIES BS BS 30E BS 36 BS 43 INSTALLATION INSTRUCTIONS SUMMARY GENERAL...3 SELECTING THE LOCATION OF UNITS...5 RELATIVE LOCATION OF THE UNITS...5
REMOTE CONTROL MANUAL
REMOTE CONTROL MANUAL ENGLISH CONTENT PRECAUTIONS...1-2 USING THE REMOTE CONTROL UNIT...3 OPERATION...4-9 Thank you for purchasing our Room Air Conditioner. Before using your air-conditioner, please read
Table of Contents. 1 - Specifications...3. 2 - Installation...3. 3 - Wiring...5. 4 - User controls...7
THERMOSTATS Table of Contents Page 1 - Specifications...3 1.1 - Product range...3 ARTTH001 (DSL-610)...3 ARTTH002 (DSL-700)...3 ARTTH003 (DSL-600)...3 1.2 - Technical data...3 1.3 - Power failures...3
Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0
Air Conditioner Service Manual 2 3 Model: AC-S13CG x 2 3 Content Technical specification.. 4 Performance curve.5 Outline & dimension of indoor unit..10 Outline & dimension of outdoor unit 11 Exploded view
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications
Use and Care Manual. Model CPA12KH AIR CONDITIONER
Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage
SWIMMING POOL HEAT PUMP (THP 55, THP 100, THP 120, THP 170) INSTALLATION AND USER GUIDE
SWIMMING POOL HEAT PUMP (THP 55, THP 100, THP 120, THP 170) INSTALLATION AND USER GUIDE i Read the instructions Contents I. Package content... 3 II. Performance and properties... 3 III. System design...
CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE080528 Models KFTHP-12 KFTHP-18 KFTHP-24 CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL
Operating Instructions Air Conditioner
F566272 Operating Instructions Air Conditioner CS-C18FFH CS-C28FFH CU-C18FFH CU-C28FFH ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101
GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101 By Jim VanderGiessen Jr, Pro Refrigeration Inc. There is a good chance your glycol chiller system is often completely forgotten about, until that dreaded day you
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced
Meaco 30L and Meaco 40L dehumidifier instruction manual
Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS
IH 17025 E Sigma Island 90
INSTRUCTIONS FOR USE Kitchen extractor hood Type: IH 17025 E Sigma Island 90 Dear Customer!! You are now a user of the newest generation kitchen extractor hood type IH 17025 E Sigma Island 90. This hood
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...
PORTABLE AIR CONDITIONER (LOCAL)
EN PORTABLE AIR CONDITIONER (LOCAL) OPERATING INSTRUCTIONS Read the instructions carefully before operating the appliance or carrying out maintenance work. Observe all the safety instructions; failure
Instruction manual for Firstline FCS12000CH
Instruction manual for Firstline FCS12000CH Contents Introduction... 2 Safety Awareness... 3 Safety Awareness... 4 Name of Parts... 5 Name of Parts... 6 Remote Controller Preparation... 7 Operation of
ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.
ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2
Dehumidifier D 850E. - Instruction manual version 02
Dehumidifier D 850E - Instruction manual version 02 Content 1. Description of dehumidifier 1.1. General data 1.2. Technical data 2. Operation and usage 2.1. Usage 2.2. Location and installation 2.3. Preparing
Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner
Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
148 OLD CONCORD TURNPIKE, BARRINGTON NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:[email protected] www.seafrost.com ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)
UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery
PANASONIC TROUBLE SHOOTING GUIDE
A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling
its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.
Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please
SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2
SERVICE MANUAL Room Air Conditioner Multi Split Wall-Mounted Type Indoor FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 NOTE: Before servicing the unit, please read this at first. Always contact with
ELECTRIC POSITION for electric heat, then confirm with Fan Test below.
Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please
SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
Split Air Conditioner
Split nditioner plit itsplit ir onditioner Split Split Split Split Split User s WNER'S 'S ER'S For s: AWI/AWO-21HPR1 Delta AWI/AWO-25HPR1 Delta AWI/AWO-32HPR1 Delta AWI/AWO-53HPR1 Delta AWI/AWO-65HPR1
Troubleshooting Your Refrigerator
Troubleshooting Your Refrigerator With conscientious care, a refrigerator will perform for years with little or no repairs. Refrigerators are categorized according to the way frost is removed from them.
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
1 DESCRIPTION OF THE APPLIANCE
1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: It is normal for a heat pump to have a build up of white frost on the outside coil during cold damp weather. The
Table Z. Troubleshooting Chart for Air Conditioners. Cause
Troubleshooting Chart for Air Conditioners Type of Unit Complaint Cause With open-type compressor Electric motor will not start Power failure Check circuit for power source Compressor stuck Locate cause
Transport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL. for SPLIT SYSTEM. Bus Air Conditioning Units.
R Transport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL for SPLIT SYSTEM Bus Air Conditioning Units T--326 Rev -- OPERATOR S MANUAL BUS AIR CONDITIONING UNITS GEN IV & GEN V CONTENTS
PORTABLE AIR CONDITIONER
VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner
HEAT RECOVERY VENTILATORS MODELS 90H-V ECM HRV, 90H-V+, 60H-V+ AND ENERGY RECOVERY VENTILATOR MODEL 90H-V ECM ERV
USER GUIDE HEAT RECOVERY VENTILATORS MODELS 90H-V ECM HRV, 90H-V+, 60H-V+ AND ENERGY RECOVERY VENTILATOR MODEL 90H-V ECM ERV PLEASE READ AND SAVE THESE INSTRUCTIONS These products earned the ENERGY STAR
Reverse Cycle Inverter Split System Air Conditioner
Reverse Cycle Inverter Split System Air Conditioner Model Number TAC-09CHSA/JAI5 INSTALLATION MANUAL Contents 03 Warranty Details 04 Welcome 05 General Safety Instructions 06 Product Overview 07 Selecting
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
Calor de Hogar. Av Tecnológico 735, PB. San Salvador Tizatlalli. Metepec, 52172, Edo de México. Teléfono (722) 216 3330 (55) 1163 6038
Calor de Hogar Av Tecnológico 735, PB San Salvador Tizatlalli Metepec, 52172, Edo de México Teléfono (722) 216 3330 (55) 1163 6038 www.calordehogar.com servicio@calordehogar. com [email protected]
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Ramsond Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...
Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)
TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) WARNING - HIGH VOLTAGE AC electrical circuits are connected to this heater. Do not attempt any service work on the
Heat Pump Installation, Maintenance and Service Manual
Heat Pump Installation, Maintenance and Service Manual This booklet is to be carefully read and instructions followed for efficient and trouble free operation of the Accent Swimming Pool Heat Pump 21 Atkinson
SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT
SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
ALL IN ONE. Heat Pump Water Heater
ALL IN ONE Heat Pump Water Heater INSTALLATION AND OPERATION INSTRUCTIONS Please read this user s manual carefully before operate the unit. www.airtradecentre.com CONTENTS A. IMPORTANT REMARKS ------------------------------------------------------------------------------------------------
USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB98-29565A(1) ENGLISH ESPAÑOL
USER S MANUAL Duct Type Series MH MH FEEA Series FUEA Series ENGLISH ESPAÑOL PORTUGUÊS E HNIKA DEUTSCH ITALIANO FRANÇAIS Free Joint Multi Air Conditioner (Cooling and Heating) E S F I P D G DB98-29565A(1)
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
WALL MOUNTED SPLIT TYPE AIR CONDITIONER
WALL MOUNTED SPLIT TYPE AIR CONDITIONER MANUAL 8 OM-G12-ACSON CONTENTS - Operating Guide page 1 - G12 Remote Controller Indication page 2 - Indicator Lights page 4 - Installation of Aroma page 5 - Auto
NSN 4120-01-21 4-3692
*TM 9-4120-388-14 TECHNICAL MANUAL Operator s, Unit, Direct Support, And General Support Maintenance Manual AIR CONDITIONER, VERTICAL, COMPACT, 18,000 BTU/HR 208 VOLT, 3 PHASE, 50/60 HERTZ NSN 4120-01-21
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
ACW200C / ACW200CH. Innovative AutoDrain Technology. Owner s Manual Portable Air Conditioner with Heat
Owner s Manual Portable Air Conditioner with Heat ACW200C / ACW200CH It is important that you read these instructions before using your new purchase and we strongly recommend that you keep them in a safe
Installation & operating instructions
Installation & operating instructions Isotherm Cruise & Drawer marine freezers Type: CR 63F INOX, CR 65F, CR 65F INOX, CR 90F, CR 90F INOX, DR 55F INOX Indel Webasto Marine USA, Inc. 3400 Gateway Drive
Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI
Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner
hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS
AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM
SECTION 7D AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM TABLE OF CONTENTS Description and Operation... 7D- General... 7D- FATC Control... 7D- FATC Input/Output Routing Diagram...
Failure code manual. content
Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一
OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex
OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex Version C Single, Dual, Tri or Quad Zone Ductless Mini-Split System Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com
CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/
CW-5000/ 5200 Contents Cautions ---------------------------------------------------------------- 3 Parts introduction --------------------------------------------------- 4 Installation ------------------------------------------------------------
OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump
R-410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H)-System, DFC4(A/H)3-Outdoor, DFF4(A/H)H-Indoor Please read the operating instructions and safety precautions carefully
Dometic turbo Direct expansion
Dometic turbo Direct expansion AIR CONDITIONING SYSTEMs installation manual Dometic Environmental Corporation Rev. 20140321 L-2484 DOMETIC TURBO DX AC INSTALLATION MANUAL CONTENTS Introduction 4 Installation
Roof Top Unit. Description Model Type Use With Air Distribution Box. Heat Pump B3200 3242 3311669.018 Integral Mechanical
RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Type Number Product Number Serial Number ADB Number ADB Serial Number Date Purchased Roof Top Unit Description Model Type Use With Air Distribution Box
Installation and maintenance instructions. Danfoss Vent
Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4
DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description
Description Compact air/water heat pump for outside installation. With suction gas cooled rotary compressor. With extensive aluminium/cu lamellar tube evaporator and PVC Titanium condenser. Axial fan Refrigerant
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español
Split-type Air-Conditioner MXZ-3A30NA MXZ-4A36NA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Français Español ATTENTION This manual mentions
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
HeatSource HS1800 Heater
HeatSource HS1800 Heater Vehical Installation & Operating Instructions Propex Heatsource Ltd Unit 5, Second Avenue Buisness Park, Milbrook, Southampton, SO15 OLP Tel: 023 8052 8555 Fax: 023 8052 8800 Website:
USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
How to Maintain an Air Conditioner
How to Maintain an Air Conditioner by Fix-It Club How to Troubleshoot a Central Air Conditioning System Publications International, Ltd. Central air conditioners are made up of two separate components:
SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service
RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS SERVICE MANUAL Troubleshooting Guide and Instructions for Service (To be performed ONLY by qualified service providers) Models Covered
with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.
B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary
NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS
INFORMATION INFORMATION ON THE TECHNOLOGY The -Frost refrigerators are different from the other static refrigerators in terms of their operational system. In normal refrigerators, in the freezing section,the
