INSTALLATION MANUAL Climma Compact Units
|
|
|
- Camron Jordan
- 9 years ago
- Views:
Transcription
1 COMPACT & SPLIT - QUATTRO INSTALLATION MANUAL Climma Compact Units Cod. A52040NA July Ver. 1
2 18 - marzo AIR-CONDITIONERS The CLIMMA air-conditioning unit is fastened to a wood base. Pay attention at opening. Unhook the unit, unscrewing the provided clamps. Keep them to fasten the unit on the boat. NOTE: YOUR UNIT MAY NOT BE EXACTLY AS SHOWN Lift the unit using the rope handles (if fitted). Take care not to lift the unit by any part that could be easily damaged. There is a label on the unit that describes its technical specifications. NOTE Check that the technical specifications, the electrical supply, etc... on the label correspond to the technical specifications of the boat. EXAMPLE OF LABEL Page 2
3
4 AIR-CONDITIONERS 3 INSTALLATION OF THE COMPONENTS FUNCTION OF AN AIR-CONDITIONER During the cooling cycle, the refrigerant circuit takes heat from the ambient air and transfers it to the sea water. Whilst doing so, it will also dehumidify and filter the air. In the reverse-cycle mode the opposite takes place, and heat is removed from the sea water and transfered to the air in the cabin Typical one-outlet installation ARRANGEMENT - General notes Choosing the unit position, it is necessary to consider the following elements: 1 - the accessibility to the air filter for cleaning; 2 - the necessary space for the fastening of the securing clips; 3 - the connection of the condensation drains; 4 - the connection of the duct to the duct ring on the unit; 5 - the connection of the sea water circuit pipes; 6 - the intended location of the electrical box. Page 4
5 AIR-CONDITIONERS 3 INSTALLATION OF THE COMPONENTS Unit Location A.- The unit must be located in the area to be conditioned. Typical locations are under a setee or bunk. A Compact unit must never be located in an engine space. B.- The conditioned air must be ducted to one or more grills through ducts of suitable size, either insulated or non-insulated. C - The return air grille should be located so that there is unobstructed air space between it and the air intake on the unit, as in picture 1.6. D - Alternatively, the unit may be reversed, as in picture 2.6. View from above Figure 1.6 View from above Figure 2.6 Page 5
6
7 AIR-CONDITIONERS 3 INSTALLATION OF THE COMPONENTS FASTENING The Compact unit should be secured as shown. Figure 1.8 NEOPRENE CONDENSATE DRAIN The Climma Compact unit will extract a significant quantity of moisture from the air, and this must be disposed of by means of a gravity condensate drain. This drain can either be to the bilge or to a sump with float-switch and pump. DO NOT lead condensate drain directly overboard. This can lead to the ingress of potentially lethal fumes from exhaust emissions, etc. efer to the safety regulations Dis 2.8 Each unit is e with two outlets, as you can see in the picture above. The condensate drain fittings provided are for 5/8" ID hose. Do not use smaller diametermm on the hose.. Condensate drains should ideally make a vertical orientation as soon as possible after the pan fitting. If both drains are to be used, they should be joined together at a point lower than the drain pan. Do not make more than one "U" trap in the condensatebe drain as this can lead to a pneumatic lock that will prevent the drain from functioning. Figure 2.8 Page 7 www.
8 AIR-CONDITIONERS 3 INSTALLATION OF THE COMPONENTS CONDENSATE DRAIN When the blower is operating, the area surrounding the Compact unit becomes a low pressure area. A trap in the drain (Fig. A) will prevent odours from being sucked up and entering the ducting system. A A Figure 1.9 Check the efficiency of the condensate drain by pouring some water into the pan AIR FILTER The Air Filter is mounted on the Compact unit in front of the air intake, and is essential for trapping dust and lint that would otherwise clog the fins on the air intake. The Air Filter should be checked and cleaned periodically, more often with high-usage units and on vessels with an abundance of carpets and rugs and with pets on board. Page 8 www.
9 AIR-CONDITIONERS 3 INSTALLATION OF THE COMPONENTS 3.8- AIR CIRCULATION SYSTEM (see examples on page 11) 3.8.A - Return Air View from above Viiew from above The cabin air returns to the Compact unit through a return air grille of appropriate dimensions. ( ) Ducting When using flexible duct, ensure that the duct maintains its diameter and is not crushed when passing through bulkheads and around. tight corners Air ducts Stretch flexible ducts so that the maximum internal diameter is maintained. Cut duct to correct length, and do not 'concertina' duct which will reduce the internal diameter. Page 9
10 AIR-CONDITIONERS 3 INSTALLATION OF THE COMPONENTS Duct Connections The collar on the blower discharge corresponds to the minimum size of duct allowable. Do not attempt to connect a duct of smaller diameter than the duct collar on the Compact unit. The blower can be rotated 90 for installations with limited height. Example of a Compact installation Page 10 www.
11 AIR-CONDITIONERS 3 INSTALLATION OF THE COMPONENTS AIR DISTRIBUTION GUIDELINES ONE OUTLET INSTALLATION A A L1 5 Btu/h Duct Length Grille area 1 2 L1 A 7,000 4" 12' 50 sq in 10,000 5" 12' 60 sq in 12,000 5" 12' 70 sq in 16,000 6" 12' 80 sq in 1 2 L1 5 A TWO OUTLET INSTALLATION A B 5 4 B L1 L2 L1 L2 Btu/h Duct L1 L1 Grille "A" Area Duct L2 L2 Grille "B" Area 7,000 4" Max 10' Min 50 sq in Max 10' Min 3" 40 sq in 10,000 5" Max 10' Min 60 sq in Max 10' Min 3" 50 sq in 12,000 5" Max 10' Min 70 sq in Max 10' Min 4" 50 sq in 16,000 6" Max 10' Min 80 sq in Max 10' Min 4" 50 sq in 1 = Air-conditioning unit 2 = Main air duct 3 = Air splitter "T" or "Y" 4 = Secondary air duct 5 = Transition, primary grille 6 = Transition, secondary grille A = Main air delivery grill B = Secondary air delivery grill DUCT SPECIFICATIONS 1 = IDEAL 2 = ACCEPTABLE 3 = UNACCEPTABLE R min =1.5 D R1-R2 min = 2D C331 05/96 Page 11
12
13
14 AIR CONDITIONERS 5 ELECTRICAL CIRCUIT WARNING AVOID THE RISK OF THE ELECTROCUTION!!! Only qualified persons should attempt installation, troubleshooting, and repair. Ensure that power to the system is disconnected before removing covers to electrical boxes. IMPORTANT NOTE To avoid possible electrical shocks that may cause injury or death, the Compact unit must be properly connected to a safety ground, as follows: 1- Use a correctly sized 3-conductor electrical cable with ground wire section and isolation. 2- Use only marine grade cable with multi-strand tinned conductors. Do not use residential wire with solid conductors 3- The ground wire must be correctly connected to the ground terminal of the panel. 4- Check that the ground connection between the electrical box and the air-conditioner has not suffered from damage during transport. 5- Check that the ground connection of the water pump is securely and properly connected in the electrical box. 6- Check the ground continuity with a multi-meter before switching off the air-conditioner. 5 ELECTRICAL CIRCUIT FX 2 ELECTRICAL BOX All electrical connections are made inside the FX 2 Power Module box. See FX 2 Manual for specific details SUPPLY Check that the available supply corresponds to the label on the unit, on the box and on the electrical pump. Power should be supplied from a breaker of the correct rating. See spec sheet for details. All electrical wiring must be marine grade, of the correct gage, and with multi-strand tinned conductors. All connections on the FX 2 terminal strip must be made with correctly sized crimp ring connectors. Page 14
15 AIR-CONDITIONERS - IMPORTANT NOTES INSTALLATION IN THE ENGINE COMPARTMENT Climma Compact air conditioners must not be installed in engine compartments under any circumstances. It is permissible to locate a Compact unit in an area outside the conditioned space and the return air ducted in to the unit. Close attention must be made to ensure adequate insulation of ducting TROUBLESHOOTING Only qualified personell can should attempt troubleshooting, with respect to the relvant the safety regulations MULTIPLE INSTALLATION On multiple-unit installations, compressor start delays must be spaced at least 5 seconds apart, with the largest unit having the shortest delay. 7 - MAINTENANCE For the efficient functioning of the air-conditioner, observe the following checks and maintenance. " Check sea water filter weekly. " Check air filter monthly. " Check and clean condensation drain every four months. " Clean condensation pan annually. " Check sea water intake whenever boat is hauled CONDENSATE DRAIN During the cooling cycle air-conditioners produce condensate water, more so in humid weather. Check periodically that there are no leaks or obstructions on the condensate outlet and that the condensate water drains properly. Pour some water in the condensation tray and check to see that it flows freely. If the condensate drains to the bilge, it is better to let it flow towards a limited space and let it drain continually to avoid stagnation that can cause unpleasant smells AIR FILTER The filter on the air inlet must be periodically cleaned and/or replaced.. Page 15
16 AIR-CONDITIONERS 8 TROUBLESHOOTING AND REPAIR IDENTIFICATION OF THE PRODUCT Each product is identified by information shown on a small yellow label. The important details are; Model Name (ex.compact 12) Part Number (ex. MC12RCI), and Serial Number (ex ) TROUBLESHOOTING Before calling for assistance, check the system. The following problems are the most common, and are typically easily solved. If, after having checked the system, there is still a problem, call the nearest CLIMMA Assistance Centre. In North America call Veco NA at or consult the web page: THE UNIT DOESN T WORK Is the breaker tripped? Reset the on the. Is the supply voltage too low? Check the voltage value between L and THE DOESN T Is the air-conditioner switched on? Switch on the unit by means of the control panel. Are there any display LED's showing on the control? THE COOLING IS NOT SUFFICIENT Have you selected the correct operational mode? Select on the panel the cooling mode (COOL) or AUTO Have you set the thermostat correctly? the. Is the fan speed too low? Increase the fan speed or select the AUTO mode Is the air circulation insufficient? Check that there are no obstructions on the outlet or inlet grills and that the filter is clean. Is the air filter dirty? Clean or replace it. Is the compressor running only for short periods? The high pressure switch w ter circulation, and Is the air circulation insufficient? Check that there are no obstructions on the outlet and inlet grills and that the air filter is clean. Is the air filter dirty? Clean or replace it Reverse Cycle "Heat Pump" units work best in waters above 45 deg F, but at higher water temperatures there is a danger that the pressures within the system exceed the safety setting and the "HP" alarm is activated. But the FX 2 does not show the "HP" alarm on the display in heat mode, and the only indication of an error is that the compressor is not functioning. the fan speed Is the air circulation insufficient? Check that there are no obstructions on the outlet and inlet grills and that the air filter is cleaned THE SEA WATER PUMP IS NOT PUMPING Has the breaker tripped? (Pump Relay installations only) After the necessary checks, re Is the pump air-bound and in need of priming? If air enters the pump head of a centrifugal (March) pump it will stop the pumping action. The air will need to be purged from the pump by removing the discharge hose. The compressor isn't operating? The high pressure switch three times. Check the sea water circuit, switch off and the on again This indicates that the high pressure switch has operated more than three times due to insufficient water flow. The system requires a re-start to operate again.. This indicates that either there is insufficient air flow or that the freeze-stat has operated (16K only). Check air flow and/or increase fan speed. Check water flow (16K only) Page 16
17 Climma Compact Systems (See over for Compact 16 and performance data) - Unique compact and space-saving design results in unobstructed air flow into unit - Tough, impact resistant poly-carb base and fan shroud results in strong, durable product - Built-in vibration dampers incorporated in design for exceptionally low noise levels - "Scavenger" type condensate drains ensure no water sloshing in drain pan - Quiet, high efficiency rotary compressors results in low current draw and starting surge - High heat transfer condensers for exceptional performance in both cool and heat modes - Raised Lanced Fin evaporators to ensure maximum possible heat and moisture removal - Quiet but powerful rotateable blowers for high efficiency and flexibility of installation - Six manual fan speeds, plus Auto, for adaptability to any application - Uses environmentally friendly "Green Gas" refrigerant, R417a (Isceon 59) - Reverse cycle heat, for maximum heating performance in Spring and Fall - Auto, Humidity, and Fan Only modes simply selected on display - Exceptionally low current draw - Can be powered from batteries through inverter - Air intake filters remove easily and quickly for routine cleaning FX 2 Digital Control - High contrast organic LED (OLED) display - Visual symbols for easy viewing of operational status - Four position joystick with push-on, push off - Adjustable brightness on display and screen-saver Imported into North America by: Annapolis MD USA voice [email protected]
18 Compact 16 - Reverse Cycle Technical Data - All Systems Supply and Return Air Compact 7 Compact 10 Compact 12 Compact 16 Min discharge grille area 50 sq in 60 sq in 70 sq in 80 sq in Min return-air grille area 80 sq in 100sq in 120 sq in 140 sq in Duct ring diameter 4" 5" 5" 6" Blower power (nominal) 270 CFM 330 CFM 400 CFM 530 CFM Water Min cooling water flow rate 1.5 GPM 2.0 GPM 3.0 GPM 3.5 GPM Recommended pump - 110v P250 P250 P500 P500 Recommended pump - 12v Flo-Jet Johnson Johnson Johnson Hose connection diameter 5/8" 5/8" 5/8" 5/8" Condensate drain diameter 5/8" 5/8" 5/8" 5/8" Electrical Requirements Circuit 15 amp 20 amp 20 amp 25 amp Min power supply wire 14 AWG 12 AWG 12 AWG 10 AWG Capacity - cooling Nominal capacity 7,000 Btu 10,000 Btu 12,000 Btu 16,000 Btu Compressor capacity - ABYC Btu 10,000 Btu 12,350 Btu 16,500 Btu System capacity as tested 6,870 Btu 9,960 Btu 12,050 Btu 16,100 Btu Cooling capability Below decks free air space 500 cu ft 715 cu ft 850 cu ft 1,140 cu ft Above decks free air space 400 cu ft 590 cu ft 700 cu ft 950 cu ft Power 115v 60Hz Power, amps, cool (nominal) Power, watts, cool (nominal) ,100 EER, cool (nominal) Weight 56 pounds 73 pounds 75 pounds 84 pounds
19 Limited Warranty Policy Veco NA, LLC (Company) warrants that if any part of a new system that includes the accompanying product proves to be defective to the original user in material or workmanship within the limits of the schedule below, the company will, at the company's option, either replace or repair that part without charge. Compressor (excluding Controller):... 5 years from date of purchase Electronic components:... 2 years from date of purchase Mechanical components:... 1 year from date of purchase Note - Items replaced or repaired under warranty are covered only for the remainder of the term of the original warranty. This warranty does not cover: Any field labor or other costs for inspection, testing, removal, transportation, or installation of any component unless pre-authorized by the Company and issuance of a Work Order number Damage, failure, or malfunction due to, or arising from, improper, faulty, or unapproved installation, servicing, and/or application, and from failing to follow the guidelines included with the equipment and in the Installation & Instruction Manual. Those parts of a system not supplied by Veco NA. Damage, failure, or malfunction resulting from accident, misuse, abuse, neglect, mishandling, alteration, modification, Acts of God, or service by personnel other than those pre-authorized by the Company. Damage, failure, or malfunction resulting from inadequate or faulty power supply to the system, or improper, faulty, or unsafe vessel wiring. Damage, failure, or malfunction due to foreign substances being injected into the system, including, but not limited to, additional refrigerant oil and/or leak detecting liquid. No responsibility is assumed for any special, incidental, or consequential damages. Note Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply. In the event of a component failure or malfunction in North America or the Caribbean, please contact Veco NA, LLC at If requested, return faulty part, freight pre-paid, together with proof of purchase. No returns will be accepted without prior authorization and the issuance of an RMA number by Veco NA. Damage due to shipping is not covered in this warranty and so it is suggested that you insure the shipment. If the part(s) is found to be defective due to faulty materials or workmanship, it will be repaired or replaced free of charge and returned freight pre-paid. If warranty service is required in areas other than North America and the Caribbean, please visit the manufacturer s web site at 7/1/09
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
COMPACT & SPLIT - QUATTRO AIR-CONDITIONERS QUATTRO
COMPACT & SPLIT - QUATTRO AIR-CONDITIONERS COMPACT end SPLIT QUATTRO models INSTALLATION MANUAL USE & SCHEMATICS COMPACT QUATTRO SPLIT QUATTRO Cod. A52040 6/9/06 S.p.A. COMPANY WITH QUALITY SYSTEM CERTIFIED
Operating Instructions Split System Air Conditioner
Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
PORTABLE AIR CONDITIONER
PORTABLE AIR CONDITIONER MAC 7500 Owner s Manual Air Conditioner Dehumidifier Oscillating Fan Please read this owner s manual carefully before operating the unit. POWERED BY 66126113.p65 17 INTRODUCTION
Quest 105, Dry155, and 205 Dual
Quest 105, Dry155, and 205 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully.
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
ICE AIR. Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE MANUAL. Wo r l d C l a s s C o m f o r t. www.ice-air.com
80 Hartford Avenue Mount Vernon New York 10553 Tel: 914-668-4700 EXT. 203 Fax: 914-668-5643 www.ice-air.com Wo r l d C l a s s C o m f o r t Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE
Ceiling Mount Air Handler Manual
www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty
Operating Instructions Air Conditioner
F566272 Operating Instructions Air Conditioner CS-C18FFH CS-C28FFH CU-C18FFH CU-C28FFH ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
Dometic turbo Direct expansion
Dometic turbo Direct expansion AIR CONDITIONING SYSTEMs installation manual Dometic Environmental Corporation Rev. 20140321 L-2484 DOMETIC TURBO DX AC INSTALLATION MANUAL CONTENTS Introduction 4 Installation
Panel Mounted Air Conditioners by Dantherm, Inc.
Panel Mounted Air Conditioners by Dantherm, Inc. CS020020A/B with USACG-6 Control PRODUCT INFORMATION MANUAL AC-2 CS020020 USACG-6 Manual Rev H Page 1 of 17 Dantherm, Inc. 110 Corporate Drive, Suite K
543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
INSTANT HOT WATER RECIRCULATING SYSTEM
INSTANT HOT WATER RECIRCULATING SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS Save manual for future reference MODEL 500800 Warning Please read carefully before proceeding with installation. Your failure
Important Safeguards
Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the
Geyser-R Heat pump water heater Installation manual
Geyser-R Heat pump water heater Installation manual 1 Version 2.9 SAFETY INFORMATION Please read carefully to prevent serious accidents or injury. The Geyser-R Heat Pump Water Heater must be installed
T-Series Air Conditioner T62 Model
INSTRUCTION MANUAL T-Series Air Conditioner T62 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200
REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:
7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: [email protected] Website: www.centrair.ca
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.
T H R U - T H E - W A L L A I R C O N D I T I O N E R S 26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. W A L L M A S T E R T H R U - T H E - W A L L A I R C O N D I T I O N E R
Air Conditioning Systems Warranty Manual. Version 1.8
Air Conditioning Systems Warranty Manual Version 1.8 1/2015 Air Conditioning System Warranty Contents Purpose 4 External Distribution... 4 Policies 5 Warranty Policy Overview... 5 Warranty Period... 5
FEEL COOL FAST. MARINE AIR CONDITIONER Installation & Operation Manual
FEEL COOL FAST MARINE AIR CONDITIONER Installation & Operation Manual 6/2012 Table of Contents INTRODUCTION... 4 PACKAGED COMPONENTS... 5 OVERVIEW... 5 INSTALLATION... 6 Unpacking and Inspection... 6
Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI
Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
Instructions & Safety Information Models A220-20D and A220-20L Version 2
Quick 220 Voltage Converting Power Supply Instructions & Safety Information Models A220-20D and A220-20L Version 2 Quick 220 Systems LLC PO Box 47489 Phoenix, Arizona 85068-7489 800-347-0394 602-938-6057
Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.
Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,
Meaco 30L and Meaco 40L dehumidifier instruction manual
Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
Operating Instructions Air Conditioner
P07-T10130 Operating Instructions Air Conditioner Indoor Unit CS-F24DD1E5 CS-F28DD1E5 CS-F34DD1E5 CS-F43DD1E5 CS-F50DD1E5 Outdoor Unit Inverter Model (HBE5 Series) CU-YL24HBE5 CU-YL28HBE5 CU-YL34HBE5 CU-YL43HBE5
Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)
UNIT OBJECTIVES Describe the concept of year-round air conditioning List three typical year-round air conditioning system types List the five ways to condition the air Determine airflow for a cooling system
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
USER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........
EXTENDED SERVICE AGREEMENTS
New from American Home Shield HEATING AND AIR CONDITIONING 5-YEAR LABOR EXTENDED SERVICE AGREEMENTS Customer Guide Last updated June 2012 2012 American Home Shield Corporation and its licensed subsidiaries.
Owner s Manual Phoenix Solution. LGR Performance Amplifier
Owner s Manual Phoenix Solution LGR Performance Amplifier Read And Save These Instructions Phoenix Solution LGR Performance Amplifier Manual Part Number TS-332 The Phoenix Solution is a LGR performance
Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español
Split-type Air-Conditioner MXZ-3A30NA MXZ-4A36NA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Français Español ATTENTION This manual mentions
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
Service & Parts Manual
Service & Parts Manual Portable Air Conditioner Models P09B and P2B ( Serial Number Beginning with an "A") Models P09B-A and P2B-A Portable Air conditioner-200 Svc Parts (4-200) Service Points and Flow
Troubleshooting Your Refrigerator
Troubleshooting Your Refrigerator With conscientious care, a refrigerator will perform for years with little or no repairs. Refrigerators are categorized according to the way frost is removed from them.
HEATER, AIR CONDITIONING AND VENTILATION
55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
Transport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL. for SPLIT SYSTEM. Bus Air Conditioning Units.
R Transport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL for SPLIT SYSTEM Bus Air Conditioning Units T--326 Rev -- OPERATOR S MANUAL BUS AIR CONDITIONING UNITS GEN IV & GEN V CONTENTS
USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat
Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage
ACW200C / ACW200CH. Innovative AutoDrain Technology. Owner s Manual Portable Air Conditioner with Heat
Owner s Manual Portable Air Conditioner with Heat ACW200C / ACW200CH It is important that you read these instructions before using your new purchase and we strongly recommend that you keep them in a safe
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
Air Conditioner 457915 B57915 459516 B59516 540315 540316 640312 640315
RECORD THIS INFORMATION FOR FUTURE REFERENCE: Number Serial Number ADB Number ADB Serial Number Date Purchased USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 CANADA Dometic
FOXAIR 60/50 ALL MODELS
FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,
Air Conditioner P O R T A B L E. Instruction Manual. Your Guarantee. For model WA-1220M WA-1220H, WA-1220E. Portable Air Conditioner / Heater
Portable Air Conditioner / Heater Your Guarantee Instruction Manual For model WA-1220M WA-1220H, WA-1220E P O R T A B L E Air Conditioner If this product is found to be faulty as a result of faulty materials
WINDOW ROOM AIR CONDITIONER
WINDOW ROOM AIR CONDITIONER Installation and Operation Manual Electromechanical Remote Control CAPACITIES 220V - 60 HZ. 12,000; 18,000; 24000 BTU/HR 220V-240V - 50 HZ. 12,000; 18,000; 24000 BTU/HR Please
USER S INFORMATION MANUAL
CONTENTS HOW YOUR SYSTEM WORKS......... 2 COOLING CYCLE....................... 2 HEATING CYCLE (HEAT PUMPS).......... 2 SYSTEM OPERATION................... 2 SETTING THE THERMOSTATS............ 2 THERMOSTATS.....................
Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split
Multi System 16 SEER, Inverter System 9,000 to 18,000 BTU/Hr Single Split 4MXW8-A 4TXM6-A March2013 42 Warnings and Cautions Warnings and Cautions. Notice that warnings and cautions appear at appropriate
Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.
Table V Troubleshooting Checklist for Refrigeration Systems TROUBLE POSSIBLE CAUSE CORRECTIVE MEASURE High condensing pressure. Low condensing pressure. Air or non-condensable gas in system. Inlet water
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
INSTALLER S & OWNER S MANUAL
INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000 DEH 3000 Part No. 4028539 Dehumidifier & Ventilation System Controller P.O. Box 8680 Madison, WI 53708 TOLL-FREE
KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle
KSV70HRF RRP AUS $1,709.00 Split System Reverse Cycle air conditioner featuring inverter technology, clean front with LED display, Bio and active carbon filter, 2 way auto swing (up, down), remote (7.1kW
HEAT PUMP FOR SWIMMING POOL Installation and Instruction Manual
HEAT PUMP FOR SWIMMING POOL Installation and Instruction Manual Revision 1.0 12.11.2013 Table of contents Table of contents... 2 1. Preface... 3 2. Specifications... 4 2.1 Performance data... 4 3. Installation
PORTABLE AIR CONDITIONER
VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner
Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008
Installation Manual Rental Services Air Handling Units July 2008 CHS-SVN01A-EN Copyright 2008 Trane All rights reserved This document and the information in it are the property of Trane and may not be
Central Air Conditioner
Central Air Conditioner USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW RESIDENTIAL AIR CONDITIONER NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. WELCOME
Owner s Manual. SRCOOL12K (120V, 60 Hz) SRXCOOL12K (230V, 50 Hz) Portable Air Conditioning Unit. Introduction 2. Important Safety Instructions 2
Warranty Registration: register online today for a chance to win a FREE Tripp Lite product www.tripplite.com/warranty Owner s Manual SRCOOLK (0V, 60 Hz) SRXCOOLK (30V, 50 Hz) Portable Air Conditioning
DBF 4XL Dryer Booster Fans
Installation and Operation Manual Item #: 401315 Rev Date: 121514 DBF 4XL Dryer Booster Fans DBF4XL Kit Includes: Dryer Booster Fan, 1 pc Fan Mounting Bracket and Hardware, 1 pc Wall Label (Mount on wasll
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS
Manual No. BLWR043 Rev. 4 September 2012 OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS CVF-8AC CVF-8AC50 CVF-6ACAN CVF-15ACAN CVF-25ACAN CVF-8A15KIT CVF-8A25KIT MODELS: CVF-8DC CVF-6DCAN CVF-15DCAN CVF-25DCAN
Reverse Cycle Inverter Split System Air Conditioner
Reverse Cycle Inverter Split System Air Conditioner Model Number TAC-09CHSA/JAI5 INSTALLATION MANUAL Contents 03 Warranty Details 04 Welcome 05 General Safety Instructions 06 Product Overview 07 Selecting
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
14. Troubleshooting Guide
14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: It is normal for a heat pump to have a build up of white frost on the outside coil during cold damp weather. The
AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS
AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS FOR AC135, AC150, AC135HP, AC150HP, ACRG12, ACTH12 RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE:
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
LOBOY 16 AIR CONDITIONERS
INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com
REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion
REDI-LINE ELECTRIC GENERATORS USER'S GUIDE Rugged, Reliable, DC to AC Power Conversion REDI-LINE ELECTRIC GENERATOR MODEL INPUT ACTUAL OUTPUT ACTUAL OUTPUT WATTS SERIAL NO. PACIFIC SCIENTIFIC MOTOR PRODUCTS
Get Me Cool Now Portable Air Conditioner User s Manual
Get Me Cool Now Portable Air Conditioner User s Manual GMCN100 SERIES Questions or Concerns? Contact technical support department at 1.877.645.0299, 8 a.m. - 5 p.m., EST, Monday - Friday or www.americancomfort.com
12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
Installation Manual. 24 VDC Rooftop Air Conditioner
SeaMach 24 VDC Rooftop Air Conditioner Installation Manual 24 VDC Rooftop Air Conditioner Chapter 1: Safety Considerations... 2 Chapter 2: General Information... 3 Chapter 3: Air Conditioning Sizing...
SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY
RV Products Division SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY Airxcel, Inc. RV Products Division P.O. Box 4020 Wichita, KS 67204 1976A376 (1-11) TABLE OF CONTENTS
DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL
DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL Service Information If service or parts are required, contact the nearest Norcold Service Center. To find an authorized Norcold Service Center
OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump
R-410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H)-System, DFC4(A/H)3-Outdoor, DFF4(A/H)H-Indoor Please read the operating instructions and safety precautions carefully
T-SERIES Air Conditioners. T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N 10-1008-177
T-SERIES Air Conditioners T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL Rev. H 2013 Pentair Equipment Protection P/N 10-1008-177 88043249 TABLE OF CONTENTS RECEIVING THE AIR CONDITIONER...3 HANDLING AND
3000W Power Inverter
3000W Power Inverter OWNER S MANUAL Model number-4573000 TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND THIS INSTRUCTIONAL MANUAL. THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING THE
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Owner s Manual Phoenix 300
PO Box 8680 Madison, WI 53708 Phoenix 300 High Capacity Dehumidifier Part number TS-218 Owner s Manual Phoenix 300 Installation, Operation and Service Instructions Read and Save These Instructions The
Installation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG
Installation and Operating Manual Model F1800C Model F1800PG Model F180C Model F180PG Model F1806C Model F1806PG www.ipsystemsusa.com Contents Safety Warnings... Items supplied... Description... Installation...4
york air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual
CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual Goodway Technologies Corporation 420 West Avenue Stamford, CT 06902-6384 (203)359-4708 Sales: 1-800-333-7467 Customer Service: 1-800-370-2855
Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC
Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C. QUICK START GUIDE Fill with
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N 10-1008-167
PROAIR Water-Cooled Air Conditioner CR43WC Model INSTRUCTION MANUAL Rev. E 2013 Pentair Technical Products P/N 10-1008-167 87976466 TABLE OF CONTENTS HANDLING & TESTING THE AIR CONDITIONER...3 INSTALLATION
WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER WITH HEATER
WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER WITH HEATER o MODEL#: ARC-14SH Instruction Manual Congratulations on your new WHYNTER product. To ensure proper operation, please read this Instruction
TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402
TECHNICAL & SERVICE MANUAL SA 79G SA 99G FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-79G-A 1 851 005 18 General (50Hz) & Europe SA-99G-A 1 851 005 19 SA 79G SA 99G REFERENCE