Surface Multi-Purposes Low Power Wireless Electromyography (EMG) system Design

Size: px
Start display at page:

Download "Surface Multi-Purposes Low Power Wireless Electromyography (EMG) system Design"

Transcription

1 Surface Multi-Purposes Low Power Wireless Electromyography (EMG) system Design Mai S. Mabrouk Biomedical Engineering Misr University for Science and Technology Al Motamyez Distinct 6 October, Egypt Olfat A. Kandil Physical Therapy, Biomechanics Dept. Misr University for Science and Technology Al Motamyez Distinct 6 October, Egypt ABSTRACT The progress in the field of electronics and technology as well as the processing of signals coupled with advance in the use of computer technology has given the opportunity to record and analyze the bio-electric signals from the human body in real time that requires dealing with many challenges according to the nature of the signal and its frequency. This could be up to 1 khz, in addition to the need to transfer data from more than one channel at the same time. Moreover, another challenge is a high sensitivity and low noise measurements of the acquired bio-electric signals which may be tens of micro volts in amplitude. For these reasons, a low power wireless Electromyography (EMG) data transfer system is designed in order to meet these challenging demands. In this work, we are able to develop an EMG analogue signal processing hardware, along with computer based supporting software. In the development of the EMG analogue signal processing hardware, many important issues have been addressed. Some of these issues include noise and artifact problems, as well as the bias DC current. The computer based software enables the user to analyze the collected EMG data and plot them on graphs for visual decision making. The work accomplished in this study enables users to use the surface EMG device for recording EMG signals for various purposes in movement analysis in medical diagnosis, rehabilitation sports medicine and ergonomics. Results revealed that the proposed system transmit and receive the signal without any losing in the information of signals. Keywords Electromyography, wireless, Biceps brachii muscle, surface electrodes, Data acquisition instrument. 1. INTRODUCTION Advances in electronics, signal processing techniques, and in computer technology have made it possible to record and process human bioelectrical signals in real time. Measuring human bioelectrical signals sets some requirements for the measuring system [1]. In most cases, the whole measurement signal bandwidth is needed to be transmitted and because the sampling frequency is normally in the range of 1 khz or even more and several measurement channels may be in use simultaneously, relatively high data transmit rates are needed. Today s low power wireless data transfer techniques are, however, able to meet this challenging demand [2]. Electromyography (EMG) is described as a device for recording the muscle activity that can be used to measure the change in the electrical potential between two points of a muscle using EMG electrodes connected to these two points [3]. It produces electrical signals as a result of muscle contraction that represents the neuromuscular activity. This means that the muscle will generate electrical signal every time it contracts. The amplitude of the electrical signal generated by the muscle activation will vary according to the force applied to move the joint, the velocity of muscle contraction and the angle of muscle pull when it contracts [4][5]. The discovery and development of the EMG signals started early in the 1666 by Francesco Redi, who was the first scientists to start, develop and research the EMG signals. He published a documentary informing that highly specialized muscles of the electrical ray fish generated electricity. After over hundred years later Walsh was able to demonstrate that the muscle tissues of an Ele fish can generate electrical spark. In 1792, A. Galvai published a paper based on electricity being able to initiate muscle contractions. In 1849, Dubios- Raymond found that it is possible to record the electrical activity of a muscle. After over 50 years later Marey was the first to record the electrical signal of muscle activation and he was the one who gave the electrical signal generated by the muscle the term Electromyography [6]. In the 1922, Gasser and Erlanger used an Oscilloscope to show the EMG signal from a muscle. However, due to the nature of the EMG signal and the noise affecting the signal, only rough information of the EMG signal could be seen and analyzed. Between the 1930s and 1950s the detection of the EMG signals improved significantly, since researches and developers started to use improved electrodes for the study of the muscles functions. After 1960 clinician started to use surface EMG electrodes for specific muscle treatments, of these were Hardyck and his research team in In the 1980 s there was a generation of new Microprocessor based EMG devices that were available at a reduced cost, and easier to use. In the last 15 years, research and development of the EMG signals has resulted in 10

2 a better understanding of the muscles and EMG signal functionality. The use of EMG during dynamic activities of various velocities necessitates the use of wireless rather than wired EMG [7]. Wireless technologies such as Wi-Fi and Bluetooth have also been incorporated into today s existing EMG equipment to provide the user with extended mobility from the PC on PCbased systems. Acquired EMG signals can now be picked up on the body and sent wirelessly to a PC where it is recorded, processed and analyzed [8, 9]. The electrical EMG signals generated by the muscles similar to other human biopotentials have very low amplitude. The amplifier in EMG device is used to amplify the EMG signals collected from the human muscle to a TTL level (±5 volts) so that it can be read by a computer using the data acquisition instrument (DAQ instrument). It is used to digitalize the analogue EMG signal so it can be read and stored into the computer. Thus, many critical factors must be considered when collecting the EMG signals, for example, noise and artifact problems could distort the signal. Additional DC current could also add offset to the EMG signal. Providing an adequate ground reference is also a significant problem. EMG setup and the need for technical support, experience to deal with sophisticated design and cost, make it optional in the clinical settings. For these reasons, there is a need to develop the setup design to include EMG device as a routine physical diagnostic test. In this work, a system of wireless EMG setup is designed to collect signals from biceps brachii muscle with the required technical support for data processing and analysis. The EMG device is used to collect the EMG signals from the biceps muscle. Moreover, the three surface electrodes are used to collect the EMG signals from the chosen muscle. Despite the relatively long-term use of EMG by investigators in a wide variety of disciplines, little information is available in the literature as to the preferred location of electrode sites. Obviously, for fine wire work the electrode is placed directly in the muscle belly of the muscle of interest. In these cases, similar criteria as used for diagnostic EMG are acceptable. For surface electromyography, however, the decision as to where to put the electrode is much less clear. Some have advocated the use of the site where the muscle can be the most easily stimulated (motor point) as where the maximum amplitude of potentials will be located. Electrode contacts should lie parallel to the muscle fibers not across them. The duration of the electrical events and the velocity of conduction, the electrode center to center separation should be between 2 to 10 mm. Caution is provided to differences in distal versus proximal muscle fibers. Recording contacts should be as large as feasible, meaning that one linear dimension should be at least equal to about half the distance between the pair of electrodes. Bipolar recording contacts should be as similar as possible in size, and impedance. Specific rules apply to the selective recording or rejection of electrical potentials [10]. The chemical electrode transducer is the means by which muscle activity may be detected. A great variety of electrodes are used in EMG but common to all electrodes is a metal electrolyte interface. The electrode is formed of metal, and the electrolyte may be an electrolytic solution or paste, as used with surface electrodes, or the tissue fluids in contact with the embedded electrode. It is at the site of the electrode electrolyte interface that an exchange occurs between the ionic current of the various tissue media and the electron current flow of recording instrumentation. The quality of an electrode as a transducing element depends on the ability of the interface to exchange ions for electrons and vice versa, with equal ease, thus preventing the formation of a charge gradient at the electrode electrolyte interfaces [11]. In the work at hands, the first two electrodes are connected across the biceps muscle to collect the EMG signal of the muscle. The third electrode is located at the elbow region of the same arm of the biceps muscle. This electrode is used to set body reference voltage. The biceps muscle was chosen as a typical superficial and for accessibility of the muscle for project demonstration. Only maximal voluntary isometric task was performed using right dominant biceps. The EMG amplifier must be designed to accommodate two surface EMG electrodes. In order to interpret the information acquired by the EMG amplifier, then DAQ instrument is used to send the data to the computer. The main components of the EMG system are proposed and the data acquisition system is also described in details. 2. METHODS The main idea of this system is to collect the Electromyography (EMG) signals from any muscles in the body such as the Biceps brachii muscle using surface electrodes, using isometric contraction at right angle elbow position and then transmit it to PC via wireless technology. These EMG signals are recorded to be used for movement analysis of the specified muscle. An EMG signal represents the electrical activity of the muscle due to the potential difference following electrode placement when a muscle is contracted. The wireless EMG system is divided into three stages: The first stage is acquiring the EMG signal; the second stage is transmitting the EMG signal using RF wireless. The third stage is receiving it for further analysis. In order to interpret the information acquired by the EMG electrodes, Analogue to digital converter (ADC) is used to digitize acquired EMG signals and Data Acquisition (DAQ) instrument is used to transmit the data to the computer and plot transmitted data for medical diagnosis, figure 1 describes the block diagram of the proposed overall Wireless Electromyography (EMG) system design. Fig 1: Block diagram of the proposed overall Wireless Electromyography (EMG) system design. 11

3 2.1 Wireless EMG System The EMG signal is acquired by placing conductive elements (electrodes) to the skin surface of the specified muscle. Three silver surface electrodes were used to acquire EMG signals of the biceps muscle. The first electrode is placed on the skin above the middle of the length of the desired muscle. Let's call this the mid muscle electrode. Next, a second electrode is placed before the insertion of the muscle. We'll call this the end muscle electrode. Last, the third electrode is placed on a bony part of the body nearby the muscle group. We'll call this the reference electrode; electrode placement is shown in Figure 2. The basic communications system consists of the following stages: - Transmitter: the sub-system that takes the information signal and processes it prior to transmission. The transmitter modulates the information onto a carrier signal, amplifies the signal and broadcasts it over the channel. The transmitter circuit diagram is shown in figure 3. - Channel: The medium which transports the modulated signal to the receiver. Air acts as the channel for broadcasts like radio. - Receiver: The sub-system that takes in the transmitted signal from the channel and processes it to retrieve the information signal. The receiver must be able to discriminate the signal from other signals which may use the same channel (called tuning), amplify the signal for processing and demodulate (remove the carrier) to retrieve the information. It also then processes the information for reception [12]; the receiver circuit diagram is shown in figure 4. The amplified EMG recordings are fed to the shift amplifier to identify the positive and negative parts of the signal and set them to the standard TTL level (±5 volts) to be transferred to the computer [14]. The amplified EMG recordings are then fed to the phase-locked loop (PLL). The HEF4046B is used as a phase-locked loop circuit that consists of a linear Voltage Controlled Oscillator (VCO) and two different phase comparators with a common signal input amplifiers and a common comparator input [15]. The TX/RX (SHY-J6122TR) 433 MHZ Modules are used for both transmit and receive operation. The two modules come together; one is receiver and the other is transmitter with a transmit power of 1W (10m), operating frequency of MHZ and operating voltage of 5V. Antenna (TLB N) with a frequency range (433MHz), input Impedance (50Ω), max-power (50W), vertical polarization Vertical, weight (5g) and height (45mm) is used as an electrical device which couples radio waves in free space to an electrical current used by a radio receiver or transmitter. Two first-order low pass filters connected or cascaded together to form a second-order or two-pole filter network is used before the transfer of EMG recordings to the computer. Fig 3: Circuit Diagram of Transmitting stage. Fig 2: Electrode placement. The EMG signal level is too low to be directly captured by a computer which uses the standard TTL level (±5 volts). Therefore, an amplification of the signal is required to increase the signal amplitude up to the TTL level. AD524 amplifier is used because of its high Common Mode Rejection Ratio (CMRR) in addition to; it is used to reject a small level signal noise which is common in both input signals and displaying the output signal as difference in voltage between the two input signals. Also, it is a very high input impedance buffer amplifier required for buffering the input voltage and preventing any voltage drop so that the same voltage at the electrodes appears at the differential inputs without any loss [13]. Fig4: Circuit Diagram of Receiving stage. 12

4 2.2 Data Acquisition (DAQ) The purpose of data acquisition is to measure an electrical or physical phenomenon such as voltage, current, temperature, pressure, or sound. PC-based data acquisition uses a combination of modular hardware, application software, and a computer to take measurements. While each data acquisition system is defined by its application requirements, every system shares a common goal of acquiring, analyzing, and presenting information. Data acquisition systems incorporate signals, sensors, actuators, signal conditioning, data acquisition devices, and application software. In this work, Data Acquisition (DAQ) is used for acquiring signals from real-world phenomena, digitizing the signals and analyzing, presenting and for saving the EMG data. It offers a significant cost and power reduction compared to a traditional flash analog-to-digital converter (ADC). The DAQ system is described as in figure 5. that can be used for statistical or higher order analysis; figure 6 describes raw EMG signal processing. Fig 6: Raw EMG signal processing Normalization The task being studied may also need to be normalized in terms of time. A cyclic activity can be set at 100 N for each cycle. This procedure allows for comparisons of data which may vary slightly in duration. This type of normalization has been used in gait analysis and when carrying loads on the back [16]. While studying shoulder joint load and muscle activity during lifting of a box, arborelius and associates expressed each task as a working cycle ratio, figure 7 describes the normalization processing of EMG signal. Fig 5: The DAQ system. A portable DAQ (NI USB-6008) with a USB connection was used for being simple and low-cost multifunction I/O device from National Instruments that can real time the signal and present it in LabVIEW, buffers the signal, Feeds the circuit by + 5V and used as analog to digital converter. Typically, DAQ boards are installed in a PC with a high speed data bus like the PCI bus. IniLab1008 communicates with a PC via the USB protocol. Depending on the speed of the motherboard of the PC, the maximum data transfers can occur between microprocessor and memory at 20 MHz to 40 MHz's. Sampling frequency and resolution are very important factors in determining the performance of a DAQ card. In this paper, we used a surface electrodes wireless EMG, to get a clear signal and apply several EMG signal processing techniques using LabVIEW such as normalization, integration, Root Mean Square (RMS), frequency spectrum and linear envelop Raw Electromyography Signal The raw EMG signal is a random signal obtained from the surface electrodes and then amplified. The raw signal should be monitored for all investigations, because the investigator can pick up major artifacts and eliminate that area or part of the signal. The ergonomist should be aware that on-off information is nominal data but the relative amount of activity is ordinal data. Interpretations that can be made in ergonomic studies are dependent on the amplifier gain and the sensitivity settings of recording instruments. No current standards exist for instrument settings or interpretive rules; therefore, considerable judgment needs to be exercised in evaluating EMG records of raw data. Such a data form is of limited value when findings are to be related to muscle force or fatigue. Thus, the signal is processed to attain a quantitative estimate Fig 7: The normalization processing of EMG signals Integration Integration requires full wave rectification followed by filtering and the use of the integrator. Integration uses all parts of the signals and represents the total amount of energy of the signals. The processed signal represents the number of motor units firing, their firing rate, the area of motor unit Integration fails to discriminate between artifacts and motor units. Noise also is a problem when recording low force level contractions. Durations may detect an unacceptably large proportion of noise when investigating low force level contraction [17]. Figure 8 describes the integration processing of EMG signals. 13

5 there may not be much emphasis forthcoming on this form of analysis; figure 9 describes the frequency spectrum processing of EMG signals. Fig 8: The integration processing of EMG signals Root Mean Square (RMS) The root-mean-square (RMS) voltage is the effective value of the quantity of an alternating current. The true RMS value of a myoelectric signal measures the electrical power in the signal. To obtain the RMS value, a ballistic galvanometer, thermocouple, strongly damped voltmeter, or digital computer may be used. A nonlinear detector may be used instead of a linear detector. The RMS signal has immediate relationship to the power spectrum. The curve represents power of the myoelectric signals. The power value is equal to the area under the spectral curve. The signal amplitude is proportional to the square root of the total signal power. The RMS has a linear relationship with tension for a brief isometric contraction; figure 8 describes the RMS processing of EMG signal. Fig 8: The RMS processing of EMG signals Frequency Spectrum The square of the magnitude of fast Fourier transform (FFT) is used for analysis [18]. The center frequency is not affected by force of contraction except at low level where it increases with increase in force because the use of spectral changes in the myoelectric signal as a valid indicator of muscle fatigue has been questioned. Frequency analysis based on zero crossings is used to study shoulder and neck disorders in assembly line workers. The results are promising and suggest that the technique is valuable for ergonomic studies at the workplace give the availability of other techniques however Fig 9: The frequency spectrum processing of EMG signals Linear Envelope A linear envelope can be used to provide an envelope that represents a profile of the myoelectric activity of the muscle over time. 2.3 Implementation A wireless EMG system is proposed to acquire and analyze EMG signals in real-time. A good visualization and analysis of these signal is essential using a successful software package. This work is written and implemented in the LabVIEW language and has been tested on the WINDOWS platform with LabVIEW. Our GUI provides a number of functions that can be used to create graphic output. A simple graphical user interface (GUI) has been developed by using LabVIEW. It aids the usage of a visual programming language that suits very well for hardware integration, and suits for general purpose programming; a snap shot of the GUI is shown in figure 6. The graphical user interface (GUI) allows the users to identify patient ID and select bandpass filters as required. 3. RESULTS AND DISCUSSION The Electromyogram (EMG), based on changes in amplitude and frequency, can be qualified and used to classify the electrical activity level that produces a certain muscular tension. The change in the myoelectric signal is based on the requirement and firing rate of motor units within the muscle, in general, as more force is needed, more motor units are required, and the motor units already firing increase their frequency of firing. This general reaction, however, is not exactly the same for every muscle. The interpretation of the changes in requirement and changes in firing rate can provide information concerning the muscle's level of force or its level of fatigue [19]. The information in this work presents a variety of ways by which the ergonomist may analyze or subsequently interpret myoelectric activity for different workplace needs. Many different methods are used to reduce the data contained in the electrical signal and to present it in numerical form. 14

6 Which method to use depends on the reason for which the information is needed, that is, the purpose of the study. The interpretation of the EMG signal plays an important role in determining the relationship of muscle activity to task performance. The most basic information obtained from a myoelectric signal is: 1) whether or not the muscle is active on/off and 2) the relative amount of activity of the muscle. By using the appropriate process of normalization, a reasonable estimate of muscle function can be obtained by the ergonomist [20]. This information can be combined with an observation system or simply an event marker of some type to determine: 1) The time at which the muscle is active. 2) The time at which a peak of activity occurs. 3) The pattern of muscle activity during a movement between agonist and antagonist. The raw, or unprocessed, EMG signal is the basis of all methods of interpreting the myoelectric activity from muscles. The ergonomist should monitor the raw signal, even though other signal processing may be used, so that artifacts can be detected and controlled as necessary for spike counting or whatever. In the past, probably the most common way to interpret EMG was by visual inspection of the raw signal with training, experience, and the use of multiple gains and oscilloscope sweep vibration, the observer should be able to evaluate the raw EMG signal visually and effectively. The observer should be able to identify when the raw signal indicates that a muscle is active and when it is relaxed. The relative amount of activity may be classified either qualitative by words, such as nil, negligible, slight, moderate, marked, or very marked, or quantitative by numerical values, such as 0-5, with 0 being no activity and 5 being maximal activity. Figure 7 shows the GUI of the proposed Wireless EMG system with recorded and processed EMG data. Fig 10: The GUI of the proposed Wireless EMG system with recorded and processed EMG data. 4. CONCLUSIONS The monitoring of vital physiological signals has proven to be one of the most efficient ways for continuous and remote tracking of the health status of patients or performance. The aim of this work is to design a wireless EMG device to help eliminate the restrictions caused by lead wires in conventional systems by permitting the acquisition and wireless transmission of a signal from sensor to recorder. This work presents the implementation of the surface EMG device. The device is implemented in three stages; analogue signal processing, DAQ and computer EMG (GUI) Capture software. The EMG analogue signal processing stage is designed to amplify EMG signals from one biceps muscle. The EMG analogue signal processing stage consists of five major components: surface EMG electrodes, Instrumentation amplifier, Shift amplifier, low pass amplifier and full transmitter and receiver wireless. The surface EMG electrodes are used as input sensors to the EMG amplifier. The amplifier is a differential instrumental amplifier which amplifies the weak and noisy EMG signals to a stable TTL level for further processing. The low pass filters are used to select only the bandwidth of signals that is of interest for the application. The wireless used to transmit and receive the signal without any losing the valuable information of signals. The DAQ stage is used to digitalize the EMG signals using the built in 12bit A/D converter. The second function of the DAQ is to transmit the digitalized EMG signal using the USB Serial communication module built in the DAQ. The EMG capture GUI program LabVIEW is developed to read the save EMG data.. The program provides necessary functions such as reading the saved EMG data filter the EMG data and analyze it. The program also provides plotting function to be used to plot the processed EMG data on a graph. This work represent phase I of the muscle recognition scenario during dynamic activity. Phase II of this work will deal with agonist /antagonist relationship. 5. REFERENCES [1] A. Cohen, "Biomedical Signals: Origin and Dynamic Characteristics; Frequency Domain Analysis," in the Biomedical Engineering Handbook, J. Bronzino Ed. Boca Raton, CRC Press, [2] Antti T. Vehkaoja, Jarmo A. Verho, Merja M. Puurtinen, Niina M. Nöjd, Jukka O. Lekkala, and Jari A. Hyttinen, Member, IEEE, Wireless Head Cap for EOG and Facial EMG Measurements, Proceedings of the 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference Shanghai, China, September 1-4, 2005 [3] Webster, John G. (1998). Medical Instrumentation: Application and Design. [4] Crosbie, J. H., Lennon, S., Basford, J. R., & McDonough, S. M, Virtual reality in stroke rehabilitation: Still more virtual than real. Disability and Rehabilitation, 29(14), , [5] Y.T. Yu, M.F. Lau, "A comparison of MC/DC, MUMCUT and several other coverage criteria for logical decisions", Journal of Systems and Software, [6] Abbink, V. D. B., Glas, V. D., Detection of onset and termination of muscle activity in surface electromyograms, Journal of Oral Rehabilitation, 25(5), [7] Hassoun, M. H., Wang, C., Spitzer, A. R., NNERVE: Neural network extraction of repetitive vectors for electromyography II, performance analysis. IEEE Transactions on Biomedical Engineering, 41(11), , [8] Vehkaoja, A., Lekkala, J., Wearable Wireless Biopotential Measurement Device, in Proceedings of 15

7 the 26th Annual Engineering in Medicine and Biology Conference, San Francisco, pp , [9] [Hughes, E., Bell, A., A Wireless Surface Electromyography System, IEEE Southeast Conference Proceedings, 253, [10] Eisenhower, W., McMichael, S., Analog control with surface electromyography, Electrical and Computer Engineering. University of Maryland, College Park, [11] B. D. Farnsworth, R. J. Triolo and D. J. Young, Wireless Implantable EMG Sensing Microsystem, IEEE Sensors Conference, pp , [12] Noraxon, I. (2010). Zero-Wire - True Wireless EMG Retrieved 4 April [13] M. Suster, J. Guo, N. Chaimanonart, W. H. Ko, and D. J. Young, A Wireless Strain Sensing Microsystem with External RF Powering and Two-Channel Data Telemetry Capability, ISSCC, pp , [14] Op Amps for Everyone, Ron Mancini (Ed.), Chapter 12, Texas Instruments Literature Number SLOD006. [15] N. Chaimanonart, M. Suster, and D. J. Young, Two- Channel Data Telemetry with Remote RF Powering for High-Performance Wireless MEMS Strain Sensing Applications, IEEE Sensors Conference, pp , [16] Pelland, L., McKinley, P., A pattern recognition technique to characterize the differential modulation of co-activating muscles at the performer/environment interface, Journal of Electromyography and Kinesiology, 14, , [17] Raez, M. B. I., Hussain, S., Mohd-Yasin, F, Techniques of EMG signal analysis: Detection, processing, classification and applications, Biological Procedures Online, 8, 11-35, [18] De Michele, G., Sello, S., Carboncini, M. C., Rossi, B., & Strambi, S., Cross-correlation time-frequency analysis for multiple EMG signals in Parkinson's diease: A wavelet approach, Medical Engineering and Physics, 25(5), , [19] Jaskolska A, Kisiel-Sajewicz K, Brzenczek-Owczarzak W, Yue G H. c, Jaskolski A, EMG and MMG of agonist and antagonist muscles as a function of age and joint angle, Journal of Electromyography and Kinesiology 16, , [20] Evetovich T K, Naumann J, Conley D S, and Todd J B, Effect of Static Stretching of the Biceps Brachii on Torque, Electromyography, and Mechanomyography During Concentric Isokinetic Muscle Actions, Journal of Strength and Conditioning Research, 17(3), ,

INTRODUCTION TO COMMUNICATION SYSTEMS AND TRANSMISSION MEDIA

INTRODUCTION TO COMMUNICATION SYSTEMS AND TRANSMISSION MEDIA COMM.ENG INTRODUCTION TO COMMUNICATION SYSTEMS AND TRANSMISSION MEDIA 9/6/2014 LECTURES 1 Objectives To give a background on Communication system components and channels (media) A distinction between analogue

More information

RF Network Analyzer Basics

RF Network Analyzer Basics RF Network Analyzer Basics A tutorial, information and overview about the basics of the RF Network Analyzer. What is a Network Analyzer and how to use them, to include the Scalar Network Analyzer (SNA),

More information

Author: Dr. Society of Electrophysio. Reference: Electrodes. should include: electrode shape size use. direction.

Author: Dr. Society of Electrophysio. Reference: Electrodes. should include: electrode shape size use. direction. Standards for Reportin ng EMG Data Author: Dr. Roberto Merletti, Politecnico di Torino, Italy The Standards for Reporting EMG Data, written by Dr. Robertoo Merletti, are endorsed by the International Society

More information

SignalPad Data Logging and Analysis Software

SignalPad Data Logging and Analysis Software SignalPad Data Logging and Analysis Software Overview SignalPad is a data logging and analysis application developed with National Instruments LabVIEW. The configuration-based user interface provides ready-to-run

More information

Product Introduction MyoMuscle. Telemyo DTS-System. Telemetry system for EMG and Biomechanical Sensors. www.noraxon.com

Product Introduction MyoMuscle. Telemyo DTS-System. Telemetry system for EMG and Biomechanical Sensors. www.noraxon.com Product Introduction MyoMuscle Telemyo DTS-System Telemetry system for EMG and Biomechanical Sensors DTS Device Family 3 major device categories can be used for the Direct Transmission System technology

More information

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP Department of Electrical and Computer Engineering Ben-Gurion University of the Negev LAB 1 - Introduction to USRP - 1-1 Introduction In this lab you will use software reconfigurable RF hardware from National

More information

Timing Errors and Jitter

Timing Errors and Jitter Timing Errors and Jitter Background Mike Story In a sampled (digital) system, samples have to be accurate in level and time. The digital system uses the two bits of information the signal was this big

More information

MATRIX TECHNICAL NOTES

MATRIX TECHNICAL NOTES 200 WOOD AVENUE, MIDDLESEX, NJ 08846 PHONE (732) 469-9510 FAX (732) 469-0418 MATRIX TECHNICAL NOTES MTN-107 TEST SETUP FOR THE MEASUREMENT OF X-MOD, CTB, AND CSO USING A MEAN SQUARE CIRCUIT AS A DETECTOR

More information

Introduction to Data Acquisition

Introduction to Data Acquisition Introduction to Data Acquisition Overview This tutorial is part of the National Instruments Measurement Fundamentals series. Each tutorial in this series, will teach you a specific topic of common measurement

More information

RF Measurements Using a Modular Digitizer

RF Measurements Using a Modular Digitizer RF Measurements Using a Modular Digitizer Modern modular digitizers, like the Spectrum M4i series PCIe digitizers, offer greater bandwidth and higher resolution at any given bandwidth than ever before.

More information

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give

More information

Vibration analysis and monitoring Compact. Powerful. Modern technology.

Vibration analysis and monitoring Compact. Powerful. Modern technology. Vibration analysis and monitoring Compact. Powerful. Modern technology. Maximum performance Vibration measurement with state of the art processor technology Expert Vibro is Delphin Technology's new device

More information

Measuring Temperature withthermistors a Tutorial David Potter

Measuring Temperature withthermistors a Tutorial David Potter NATIONAL INSTRUMENTS The Software is the Instrument Application Note 065 Measuring Temperature withthermistors a Tutorial David Potter Introduction Thermistors are thermally sensitive resistors used in

More information

Laboratory Guide. Anatomy and Physiology

Laboratory Guide. Anatomy and Physiology Laboratory Guide Anatomy and Physiology TBME04, Fall 2010 Name: Passed: Last updated 2010-08-13 Department of Biomedical Engineering Linköpings Universitet Introduction This laboratory session is intended

More information

Type-D EEG System for Regular EEG Clinic

Type-D EEG System for Regular EEG Clinic Type-D EEG System for Regular EEG Clinic Type-D EEG amplifier Specifications 1. For Type-D Amplifier Input channels: 12/24/36/48 Monopolar EEG + 12channels Bipolar EEG+12 channels PSG. Power supply: Internal

More information

Making Accurate Voltage Noise and Current Noise Measurements on Operational Amplifiers Down to 0.1Hz

Making Accurate Voltage Noise and Current Noise Measurements on Operational Amplifiers Down to 0.1Hz Author: Don LaFontaine Making Accurate Voltage Noise and Current Noise Measurements on Operational Amplifiers Down to 0.1Hz Abstract Making accurate voltage and current noise measurements on op amps in

More information

Email: [email protected]

Email: tjohn@mail.nplindia.ernet.in USE OF VIRTUAL INSTRUMENTS IN RADIO AND ATMOSPHERIC EXPERIMENTS P.N. VIJAYAKUMAR, THOMAS JOHN AND S.C. GARG RADIO AND ATMOSPHERIC SCIENCE DIVISION, NATIONAL PHYSICAL LABORATORY, NEW DELHI 110012, INDIA

More information

Application Note Noise Frequently Asked Questions

Application Note Noise Frequently Asked Questions : What is? is a random signal inherent in all physical components. It directly limits the detection and processing of all information. The common form of noise is white Gaussian due to the many random

More information

PCM Encoding and Decoding:

PCM Encoding and Decoding: PCM Encoding and Decoding: Aim: Introduction to PCM encoding and decoding. Introduction: PCM Encoding: The input to the PCM ENCODER module is an analog message. This must be constrained to a defined bandwidth

More information

Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements. Application Note 1304-6

Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements. Application Note 1304-6 Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements Application Note 1304-6 Abstract Time domain measurements are only as accurate as the trigger signal used to acquire them. Often

More information

ONLINE HEALTH MONITORING SYSTEM USING ZIGBEE

ONLINE HEALTH MONITORING SYSTEM USING ZIGBEE ONLINE HEALTH MONITORING SYSTEM USING ZIGBEE S.Josephine Selvarani ECE Department, Karunya University, Coimbatore. Abstract - An on-line health monitoring of physiological signals of humans such as temperature

More information

The Development of a Pressure-based Typing Biometrics User Authentication System

The Development of a Pressure-based Typing Biometrics User Authentication System The Development of a Pressure-based Typing Biometrics User Authentication System Chen Change Loy Adv. Informatics Research Group MIMOS Berhad by Assoc. Prof. Dr. Chee Peng Lim Associate Professor Sch.

More information

Clock Recovery in Serial-Data Systems Ransom Stephens, Ph.D.

Clock Recovery in Serial-Data Systems Ransom Stephens, Ph.D. Clock Recovery in Serial-Data Systems Ransom Stephens, Ph.D. Abstract: The definition of a bit period, or unit interval, is much more complicated than it looks. If it were just the reciprocal of the data

More information

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

Product Information S N O. Portable VIP protection CCTV & Alarm System 2 Product Information S N O Portable VIP protection CCTV & Alarm System 2 G O V E R N M E N T A L S E C U R I T Y S O L U T I VIP KIT Rapid Deployment VIP Protection Kit The VIP KIT has been designed to

More information

Electrocardiogram (ECG) Monitoring System using Bluetooth technology

Electrocardiogram (ECG) Monitoring System using Bluetooth technology Electrocardiogram (ECG) Monitoring System using Bluetooth technology Zarina Md Amin, Suryani Ilias, Zunuwanas Mohamad Department of Electrical Engineering, Polytechnic of Sultan Abdul Salahuddin Abdul

More information

Siemens and National Instruments Deliver Integrated Automation and Measurement Solutions

Siemens and National Instruments Deliver Integrated Automation and Measurement Solutions Siemens and National Instruments Deliver Integrated Automation and Measurement Solutions The Need for Integrated Automation and Measurement Manufacturing lines consist of numerous decoupled systems for

More information

Engineering Sciences 151. Electromagnetic Communication Laboratory Assignment 3 Fall Term 1998-99

Engineering Sciences 151. Electromagnetic Communication Laboratory Assignment 3 Fall Term 1998-99 Engineering Sciences 151 Electromagnetic Communication Laboratory Assignment 3 Fall Term 1998-99 WAVE PROPAGATION II: HIGH FREQUENCY SLOTTED LINE AND REFLECTOMETER MEASUREMENTS OBJECTIVES: To build greater

More information

FREQUENCY RESPONSE ANALYZERS

FREQUENCY RESPONSE ANALYZERS FREQUENCY RESPONSE ANALYZERS Dynamic Response Analyzers Servo analyzers When you need to stabilize feedback loops to measure hardware characteristics to measure system response BAFCO, INC. 717 Mearns Road

More information

Real Time Monitoring using Surface Electromyography

Real Time Monitoring using Surface Electromyography Real Time Monitoring using Surface Electromyography Md. Shafivulla1 Vullanki Rajesh2 Ch. Raghava Prasad3 K. V. V. Kumar4 S. Sreedhar Babu5 1.5. Associate Professor, School of Electrical Sciences, Dept.

More information

Optimizing IP3 and ACPR Measurements

Optimizing IP3 and ACPR Measurements Optimizing IP3 and ACPR Measurements Table of Contents 1. Overview... 2 2. Theory of Intermodulation Distortion... 2 3. Optimizing IP3 Measurements... 4 4. Theory of Adjacent Channel Power Ratio... 9 5.

More information

A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION

A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION 35'th Annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting San Diego, December 2-4, 2003 A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION Józef Kalisz and Ryszard Szplet

More information

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display

More information

Impedance 50 (75 connectors via adapters)

Impedance 50 (75 connectors via adapters) VECTOR NETWORK ANALYZER PLANAR TR1300/1 DATA SHEET Frequency range: 300 khz to 1.3 GHz Measured parameters: S11, S21 Dynamic range of transmission measurement magnitude: 130 db Measurement time per point:

More information

Use and Application of Output Limiting Amplifiers (HFA1115, HFA1130, HFA1135)

Use and Application of Output Limiting Amplifiers (HFA1115, HFA1130, HFA1135) Use and Application of Output Limiting Amplifiers (HFA111, HFA110, HFA11) Application Note November 1996 AN96 Introduction Amplifiers with internal voltage clamps, also known as limiting amplifiers, have

More information

Gage Applied Technologies

Gage Applied Technologies Copyright 2004 As seen in Evaluation Engineering/September 2004 1 Use of a PC-Based Digitizer in an Ultrasonic Flaw-Detection System Written by: Andrew Dawson, Ph.D. ABSTRACT: Use of modern high-speed

More information

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies Soonwook Hong, Ph. D. Michael Zuercher Martinson Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies 1. Introduction PV inverters use semiconductor devices to transform the

More information

Android based Alcohol detection system using Bluetooth technology

Android based Alcohol detection system using Bluetooth technology For more Project details visit: http://www.projectsof8051.com/android-based-alcohol-detection-system-usingbluetooth-technology/ Code 1435 Project Title Android based Alcohol detection system using Bluetooth

More information

MAINTENANCE & ADJUSTMENT

MAINTENANCE & ADJUSTMENT MAINTENANCE & ADJUSTMENT Circuit Theory The concept of PLL system frequency synthesization is not of recent development, however, it has not been a long age since the digital theory has been couplet with

More information

Reading: HH Sections 4.11 4.13, 4.19 4.20 (pgs. 189-212, 222 224)

Reading: HH Sections 4.11 4.13, 4.19 4.20 (pgs. 189-212, 222 224) 6 OP AMPS II 6 Op Amps II In the previous lab, you explored several applications of op amps. In this exercise, you will look at some of their limitations. You will also examine the op amp integrator and

More information

T = 1 f. Phase. Measure of relative position in time within a single period of a signal For a periodic signal f(t), phase is fractional part t p

T = 1 f. Phase. Measure of relative position in time within a single period of a signal For a periodic signal f(t), phase is fractional part t p Data Transmission Concepts and terminology Transmission terminology Transmission from transmitter to receiver goes over some transmission medium using electromagnetic waves Guided media. Waves are guided

More information

INSTRUMENTATION AND CONTROL TUTORIAL 3 SIGNAL PROCESSORS AND RECEIVERS

INSTRUMENTATION AND CONTROL TUTORIAL 3 SIGNAL PROCESSORS AND RECEIVERS INSTRUMENTATION AND CONTROL TUTORIAL 3 SIGNAL PROCESSORS AND RECEIVERS This tutorial provides an overview of signal processing and conditioning for use in instrumentation and automatic control systems.

More information

Non-Data Aided Carrier Offset Compensation for SDR Implementation

Non-Data Aided Carrier Offset Compensation for SDR Implementation Non-Data Aided Carrier Offset Compensation for SDR Implementation Anders Riis Jensen 1, Niels Terp Kjeldgaard Jørgensen 1 Kim Laugesen 1, Yannick Le Moullec 1,2 1 Department of Electronic Systems, 2 Center

More information

Frequency Response of Filters

Frequency Response of Filters School of Engineering Department of Electrical and Computer Engineering 332:224 Principles of Electrical Engineering II Laboratory Experiment 2 Frequency Response of Filters 1 Introduction Objectives To

More information

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card Machinery Protection Card Type FEATURES Continuous on-line Machinery Protection Card Real-time measurement and monitoring using state-of-the-art DSP techniques Fully VME-compatible slave interface Fully

More information

Demystifying Wireless for Real-World Measurement Applications

Demystifying Wireless for Real-World Measurement Applications Proceedings of the IMAC-XXVIII February 1 4, 2010, Jacksonville, Florida USA 2010 Society for Experimental Mechanics Inc. Demystifying Wireless for Real-World Measurement Applications Kurt Veggeberg, Business,

More information

THE INFLUENCE OF WALL PAINTING ON SHOULDER MUSCLE ACTIVITY AND HORIZONTAL PUSH FORCE

THE INFLUENCE OF WALL PAINTING ON SHOULDER MUSCLE ACTIVITY AND HORIZONTAL PUSH FORCE THE INFLUENCE OF WALL PAINTING ON SHOULDER MUSCLE ACTIVITY AND HORIZONTAL PUSH FORCE Background: Patricia M. Rosati and Clark R. Dickerson Department of Kinesiology, University of Waterloo, Waterloo, ON

More information

AM TRANSMITTERS & RECEIVERS

AM TRANSMITTERS & RECEIVERS Reading 30 Ron Bertrand VK2DQ http://www.radioelectronicschool.com AM TRANSMITTERS & RECEIVERS Revision: our definition of amplitude modulation. Amplitude modulation is when the modulating audio is combined

More information

AND9035/D. BELASIGNA 250 and 300 for Low-Bandwidth Applications APPLICATION NOTE

AND9035/D. BELASIGNA 250 and 300 for Low-Bandwidth Applications APPLICATION NOTE BELASIGNA 250 and 300 for Low-Bandwidth Applications APPLICATION NOTE Introduction This application note describes the use of BELASIGNA 250 and BELASIGNA 300 in low bandwidth applications. The intended

More information

Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B)

Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B) Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B) 1. Description and Specifications Contents 1.1 Description 1.2 1.2 Specifications 1.3 1.3 Tested parameters in production

More information

Propagation Channel Emulator ECP_V3

Propagation Channel Emulator ECP_V3 Navigation simulators Propagation Channel Emulator ECP_V3 1 Product Description The ECP (Propagation Channel Emulator V3) synthesizes the principal phenomena of propagation occurring on RF signal links

More information

Design of a Wireless Medical Monitoring System * Chavabathina Lavanya 1 G.Manikumar 2

Design of a Wireless Medical Monitoring System * Chavabathina Lavanya 1 G.Manikumar 2 Design of a Wireless Medical Monitoring System * Chavabathina Lavanya 1 G.Manikumar 2 1 PG Student (M. Tech), Dept. of ECE, Chirala Engineering College, Chirala., A.P, India. 2 Assistant Professor, Dept.

More information

THE BASICS OF PLL FREQUENCY SYNTHESIS

THE BASICS OF PLL FREQUENCY SYNTHESIS Supplementary Reading for 27 - Oscillators Ron Bertrand VK2DQ http://www.radioelectronicschool.com THE BASICS OF PLL FREQUENCY SYNTHESIS The phase locked loop (PLL) method of frequency synthesis is now

More information

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus Please do not remove this manual from from the lab. It is available at www.cm.ph.bham.ac.uk/y2lab Optics Introduction Optical fibres are widely used for transmitting data at high speeds. In this experiment,

More information

Process Control and Automation using Modbus Protocol

Process Control and Automation using Modbus Protocol Process Control and Automation using Modbus Protocol Modbus is the fundamental network protocol used in most industrial applications today. It is universal, open and an easy to use protocol. Modbus has

More information

Op Amp Circuit Collection

Op Amp Circuit Collection Op Amp Circuit Collection Note: National Semiconductor recommends replacing 2N2920 and 2N3728 matched pairs with LM394 in all application circuits. Section 1 Basic Circuits Inverting Amplifier Difference

More information

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER W. Li, J. Vandewege Department of Information Technology (INTEC) University of Gent, St.Pietersnieuwstaat 41, B-9000, Gent, Belgium Abstract: Precision

More information

Ultrasound Distance Measurement

Ultrasound Distance Measurement Final Project Report E3390 Electronic Circuits Design Lab Ultrasound Distance Measurement Yiting Feng Izel Niyage Asif Quyyum Submitted in partial fulfillment of the requirements for the Bachelor of Science

More information

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display

More information

Software Defined Radio

Software Defined Radio Software Defined Radio GNU Radio and the USRP Overview What is Software Defined Radio? Advantages of Software Defined Radio Traditional versus SDR Receivers SDR and the USRP Using GNU Radio Introduction

More information

Understanding the Effect of Uncorrelated Phase Noise on Multi-channel RF Vector Signal Generators and Analysers

Understanding the Effect of Uncorrelated Phase Noise on Multi-channel RF Vector Signal Generators and Analysers Understanding the Effect of Uncorrelated Phase Noise on Multi-channel RF Vector Signal Generators and Analysers David A. Hall, Product Marketing Manager Andy Hinde, RF Systems Engineer Introduction With

More information

Analog Signal Conditioning

Analog Signal Conditioning Analog Signal Conditioning Analog and Digital Electronics Electronics Digital Electronics Analog Electronics 2 Analog Electronics Analog Electronics Operational Amplifiers Transistors TRIAC 741 LF351 TL084

More information

11. High-Speed Differential Interfaces in Cyclone II Devices

11. High-Speed Differential Interfaces in Cyclone II Devices 11. High-Speed Differential Interfaces in Cyclone II Devices CII51011-2.2 Introduction From high-speed backplane applications to high-end switch boxes, low-voltage differential signaling (LVDS) is the

More information

Chapter 6. Components of Elasticity. Musculotendinous Unit. Behavioral Properties of the Musculotendinous Unit. Biomechanics of Skeletal Muscle

Chapter 6. Components of Elasticity. Musculotendinous Unit. Behavioral Properties of the Musculotendinous Unit. Biomechanics of Skeletal Muscle Chapter 6 Behavioral Properties of the Musculotendinous Unit 1) extensibility: ability to be stretched or to increase in length 2) elasticity: ability to return to normal resting length following a stretch

More information

ANIMA: Non-Conventional Interfaces in Robot Control Through Electroencephalography and Electrooculography: Motor Module

ANIMA: Non-Conventional Interfaces in Robot Control Through Electroencephalography and Electrooculography: Motor Module Ninth LACCEI Latin American and Caribbean Conference (LACCEI 2011), Engineering for a Smart Planet, Innovation, Information Technology and Computational Tools for Sustainable Development, August 3-5, 2011,

More information

Hello and welcome to this training module for the STM32L4 Liquid Crystal Display (LCD) controller. This controller can be used in a wide range of

Hello and welcome to this training module for the STM32L4 Liquid Crystal Display (LCD) controller. This controller can be used in a wide range of Hello and welcome to this training module for the STM32L4 Liquid Crystal Display (LCD) controller. This controller can be used in a wide range of applications such as home appliances, medical, automotive,

More information

Data Acquisition Basics Lab

Data Acquisition Basics Lab Data Acquisition Basics Lab Introduction Many systems in the body can be modeled as electrical systems that interact with various organs, such as the heart, the brain, and body muscle. These systems communicate

More information

The front end of the receiver performs the frequency translation, channel selection and amplification of the signal.

The front end of the receiver performs the frequency translation, channel selection and amplification of the signal. Many receivers must be capable of handling a very wide range of signal powers at the input while still producing the correct output. This must be done in the presence of noise and interference which occasionally

More information

QAM Demodulation. Performance Conclusion. o o o o o. (Nyquist shaping, Clock & Carrier Recovery, AGC, Adaptive Equaliser) o o. Wireless Communications

QAM Demodulation. Performance Conclusion. o o o o o. (Nyquist shaping, Clock & Carrier Recovery, AGC, Adaptive Equaliser) o o. Wireless Communications 0 QAM Demodulation o o o o o Application area What is QAM? What are QAM Demodulation Functions? General block diagram of QAM demodulator Explanation of the main function (Nyquist shaping, Clock & Carrier

More information

Basics of Simulation Technology (SPICE), Virtual Instrumentation and Implications on Circuit and System Design

Basics of Simulation Technology (SPICE), Virtual Instrumentation and Implications on Circuit and System Design Basics of Simulation Technology (SPICE), Virtual Instrumentation and Implications on Circuit and System Design Patrick Noonan Business Development Manager National Instruments Electronics Workbench Group

More information

APPLICATION NOTE ULTRASONIC CERAMIC TRANSDUCERS

APPLICATION NOTE ULTRASONIC CERAMIC TRANSDUCERS APPLICATION NOTE ULTRASONIC CERAMIC TRANSDUCERS Selection and use of Ultrasonic Ceramic Transducers The purpose of this application note is to aid the user in the selection and application of the Ultrasonic

More information

A DESIGN OF DSPIC BASED SIGNAL MONITORING AND PROCESSING SYSTEM

A DESIGN OF DSPIC BASED SIGNAL MONITORING AND PROCESSING SYSTEM ISTANBUL UNIVERSITY JOURNAL OF ELECTRICAL & ELECTRONICS ENGINEERING YEAR VOLUME NUMBER : 2009 : 9 : 1 (921-927) A DESIGN OF DSPIC BASED SIGNAL MONITORING AND PROCESSING SYSTEM Salih ARSLAN 1 Koray KÖSE

More information

How PLL Performances Affect Wireless Systems

How PLL Performances Affect Wireless Systems May 2010 Issue: Tutorial Phase Locked Loop Systems Design for Wireless Infrastructure Applications Use of linear models of phase noise analysis in a closed loop to predict the baseline performance of various

More information

Maximizing Receiver Dynamic Range for Spectrum Monitoring

Maximizing Receiver Dynamic Range for Spectrum Monitoring Home Maximizing Receiver Dynamic Range for Spectrum Monitoring Brian Avenell, National Instruments Corp., Austin, TX October 15, 2012 As consumers continue to demand more data wirelessly through mobile

More information

Chapter 1. Introduction. 1.1 The Challenge of Computer Generated Postures

Chapter 1. Introduction. 1.1 The Challenge of Computer Generated Postures Chapter 1 Introduction 1.1 The Challenge of Computer Generated Postures With advances in hardware technology, more powerful computers become available for the majority of users. A few years ago, computer

More information

Computer Networks and Internets, 5e Chapter 6 Information Sources and Signals. Introduction

Computer Networks and Internets, 5e Chapter 6 Information Sources and Signals. Introduction Computer Networks and Internets, 5e Chapter 6 Information Sources and Signals Modified from the lecture slides of Lami Kaya ([email protected]) for use CECS 474, Fall 2008. 2009 Pearson Education Inc., Upper

More information

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry

More information

Cell Phone Vibration Experiment

Cell Phone Vibration Experiment Objective Cell Phone Vibration Experiment Most cell phones are designed to vibrate. But at what frequency do they vibrate? With an accelerometer, data acquisition and signal analysis the vibration frequency

More information

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics Jeff Thomas Tom Holmes Terri Hightower Learn RF Spectrum Analysis Basics Agenda Overview: Spectrum analysis and its measurements Theory of Operation: Spectrum analyzer hardware Frequency Specifications

More information

Application Note Receiving HF Signals with a USRP Device Ettus Research

Application Note Receiving HF Signals with a USRP Device Ettus Research Application Note Receiving HF Signals with a USRP Device Ettus Research Introduction The electromagnetic (EM) spectrum between 3 and 30 MHz is commonly referred to as the HF band. Due to the propagation

More information

SmartDiagnostics Application Note Wireless Interference

SmartDiagnostics Application Note Wireless Interference SmartDiagnostics Application Note Wireless Interference Publication Date: May 27, 2015 KCF Technologies, Inc. Background The SmartDiagnostics wireless network is an easy to install, end-to-end machine

More information

Digital Single Axis Controller

Digital Single Axis Controller Digital Single Axis Controller The concept of intelligent hydraulic drive a vision? DSAC (Digital Single Axis Controller) Do you need hydraulic servo drive for your machine/system? What would it be like

More information

Microcontroller-based experiments for a control systems course in electrical engineering technology

Microcontroller-based experiments for a control systems course in electrical engineering technology Microcontroller-based experiments for a control systems course in electrical engineering technology Albert Lozano-Nieto Penn State University, Wilkes-Barre Campus, Lehman, PA, USA E-mail: [email protected]

More information

Honeywell Primus HF 1050 HF Radio System

Honeywell Primus HF 1050 HF Radio System Honeywell Primus HF 1050 HF Radio System 1 HF Technical Description Honeywell s new 28Vdc HF radio advances the performance and capability of our HF systems to meet the emerging needs of the HF market

More information

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V 14.5GHZ 2.2KW CW GENERATOR GKP 22KP 14.5GHz WR62 3x400V UTILIZATION OF GKP 22KP GENERATOR With its characteristics of power stability whatever the load, very fast response time at a pulse, low ripple,

More information

APSYN420A/B Specification 1.24. 0.65-20.0 GHz Low Phase Noise Synthesizer

APSYN420A/B Specification 1.24. 0.65-20.0 GHz Low Phase Noise Synthesizer APSYN420A/B Specification 1.24 0.65-20.0 GHz Low Phase Noise Synthesizer 1 Introduction The APSYN420 is a wideband low phase-noise synthesizer operating from 0.65 to 20 GHz. The nominal output power is

More information

INTERFERENCE OF SOUND WAVES

INTERFERENCE OF SOUND WAVES 1/2016 Sound 1/8 INTERFERENCE OF SOUND WAVES PURPOSE: To measure the wavelength, frequency, and propagation speed of ultrasonic sound waves and to observe interference phenomena with ultrasonic sound waves.

More information

Active Vibration Isolation of an Unbalanced Machine Spindle

Active Vibration Isolation of an Unbalanced Machine Spindle UCRL-CONF-206108 Active Vibration Isolation of an Unbalanced Machine Spindle D. J. Hopkins, P. Geraghty August 18, 2004 American Society of Precision Engineering Annual Conference Orlando, FL, United States

More information

AM/FM/ϕM Measurement Demodulator FS-K7

AM/FM/ϕM Measurement Demodulator FS-K7 Data sheet Version 02.00 AM/FM/ϕM Measurement Demodulator FS-K7 July 2005 for the Analyzers FSQ/FSU/FSP and the Test Receivers ESCI/ESPI AM/FM/ϕM demodulator for measuring analog modulation parameters

More information

Introduction to Receivers

Introduction to Receivers Introduction to Receivers Purpose: translate RF signals to baseband Shift frequency Amplify Filter Demodulate Why is this a challenge? Interference (selectivity, images and distortion) Large dynamic range

More information

Electrical Resonance

Electrical Resonance Electrical Resonance (R-L-C series circuit) APPARATUS 1. R-L-C Circuit board 2. Signal generator 3. Oscilloscope Tektronix TDS1002 with two sets of leads (see Introduction to the Oscilloscope ) INTRODUCTION

More information

Increase System Efficiency with Condition Monitoring. Embedded Control and Monitoring Summit National Instruments

Increase System Efficiency with Condition Monitoring. Embedded Control and Monitoring Summit National Instruments Increase System Efficiency with Condition Monitoring Embedded Control and Monitoring Summit National Instruments Motivation of Condition Monitoring Impeller Contact with casing and diffuser vanes Bent

More information

INTRODUCTION: ABSTRACT:

INTRODUCTION: ABSTRACT: INDUSTRIAL INTELLIGENT LINE FOLLOWER ROBOT WITH AUTO GO DOWN DETECTION, AUTO OBSTACLES DETECTION, WIRELESS VEHICLE STATUS DATA TRANFER TO SERVER AND MANY MORE FEATURES INTRODUCTION: This project is based

More information

Technical Note Series

Technical Note Series Technical Note Series SKIN CONDUCTANCE SENSOR (SA9309M) S TN0 0 0 8-0 0 S k i n C o n d u c t a n c e S e n s o r Page 2 IMPORTANT OPERATION INFORMATION WARNING Type BF Equipment Internally powered equipment

More information

Section 3. Sensor to ADC Design Example

Section 3. Sensor to ADC Design Example Section 3 Sensor to ADC Design Example 3-1 This section describes the design of a sensor to ADC system. The sensor measures temperature, and the measurement is interfaced into an ADC selected by the systems

More information

RECOMMENDATION ITU-R F.1113. (Question ITU-R 157/9) b) that systems using this mode of propagation are already in service for burst data transmission,

RECOMMENDATION ITU-R F.1113. (Question ITU-R 157/9) b) that systems using this mode of propagation are already in service for burst data transmission, Rec. ITU-R F.1113 1 RECOMMENDATION ITU-R F.1113 RADIO SYSTEMS EMPLOYING METEOR-BURST PROPAGATION (Question ITU-R 157/9) (1994) Rec. ITU-R F.1113 The ITU Radiocommunication Assembly, considering a) that

More information

Various Technics of Liquids and Solids Level Measurements. (Part 3)

Various Technics of Liquids and Solids Level Measurements. (Part 3) (Part 3) In part one of this series of articles, level measurement using a floating system was discusses and the instruments were recommended for each application. In the second part of these articles,

More information

Benefits and Potential Dangers of Using USB for Test & Measurement Applications. Benefits of Using USB for Test and Measurement

Benefits and Potential Dangers of Using USB for Test & Measurement Applications. Benefits of Using USB for Test and Measurement Benefits and Potential Dangers of Using USB for Test & Measurement Applications What is USB? USB (Universal Serial Bus) is a standard that was developed by a group of manufacturers (including Intel, Microsoft,

More information

Application Note SAW-Components

Application Note SAW-Components Application Note SAW-Components Principles of SAWR-stabilized oscillators and transmitters. App: Note #1 This application note describes the physical principle of SAW-stabilized oscillator. Oscillator

More information

Human Detection Robot using PIR Sensors

Human Detection Robot using PIR Sensors Human Detection Robot using PIR Sensors Saravana Kumar K, Priscilla P, Germiya K Jose, Balagopal G Abstract: Human Detection Robot is a robot that can detect the presence of human; it sends the signal

More information