Review of the Cooling Technology for High-power Wind Turbines
|
|
|
- Mariah Cooper
- 9 years ago
- Views:
Transcription
1 5th International Conference on Advanced Design and Manufacturing Engineering (ICADME 2015) Review of the Cooling Technology for High-power Wind Turbines Sheng Jian a *, Meng Xiaoqian b, Chu Shuying c and Guo Huijing d School of Energy and Power Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Yangpu District, Shanghai, China, a [email protected], b @qq.com, c @qq.com, d @qq.com Keywords: wind turbine; cooling technology; heat pipe Abstract. With the increasing of wind turbine unit capacity, heat load of thermal dissipation components of the unit increase greatly. In order to make the unit long-term stably and efficiency operation, the research and development of cooling system with high efficiency and low energy consumption become particularly important. The main sources of waste heat and the widely used six kinds of cooling technology was described. Also there is a detailed analysis of the pros and cons of each one, and the gravity heat pipe was designed which is instead of the above cooling systems. This cooling technology have high heat transfer efficiency and no cooling medium delivery device and simple structure and low initial investment and operating costs. Introduction According to the Global Wind Energy Council statistics, 2014 global new capacity is 51477MW, and Chinese new capacity is 23351MW, 45.2% of the total. The global cumulative installed capacity is MW in 2014, while the cumulative installed capacity is MW in China, 31.0% of the total, ranking the first of the world. At present, 6MW offshore wind turbine has been developed and produced by Guodian United Power Technology (Baoding) Co., Ltd. which is the single most powerful wind turbine currently. Due to the rapid growth in unit capacity, the waste heat of wind turbine increases a lot. A more efficient cooling system is needed to timely discharge the heat to the environment, which is extremely important for a long-term stable operation of wind turbines. Currently, researchers focused on seismic measures, inverter technology and mechanical design and other fields in China, but the cooling technology of wind turbine is rarely researched [1]. In foreign, the introduction of high-power wind turbines are rarely reported due to technical protection. The present situation of cooling technology for wind turbine are summarized, and several kinds of typical cooling technology are comprehensive compared and a more energy efficient new wind turbine cooling system is designed. The heat load on the wind turbine The wind turbine generates electricity by wind, but about 5% power is changed to waste heat and the main heat-generating components include gear box, control inverter, generator, brake mechanism, direction adjust device and variable pitch system, etc. The heat load is related to the wind turbine s type, size and production process, etc. And in the MW wind turbines, the gear box, generator and control inverter are the main heating components. The waste heat produced by gear box. The heat load in the gear box mainly raises the oil temperature. The heat is mainly produced by gear box process to overcome the friction that part of kinetic energy change into heat energy, which causing temperature rise [2]. The viscosity of the oil will decline and become thin by the temperature increase, so lubricating oil film is destroyed, the gear s friction increases, and calorific value increase more, which resulting in a vicious cycle. And if the temperature is too high that makes the tooth surface gluing, so as to damage the gear, which may result in huge losses. Therefore, to ensure the normal operation, heat exchange between the gear box and cooling fluid must be good [3] The authors - Published by Atlantis Press 1798
2 The waste heat produced by generator. The heat load of the generator comes from: (1) Copper loss, namely generator components around the winding copper wires, due to the copper wire resistance, part of electrical energy is transformed into heat energy; (2) Iron loss, is due to the rotation of the core hysteresis effect of eddy current, resulting in hysteresis loss and eddy current loss; (3) Mechanical loss, that part of the energy is used during generator operation to overcome the friction. All of these energy loss will ultimately transformed into heat energy, distributed into the wind turbine nacelle [4]. The linear generator size, magnetic load and line load are the main ways to increase unit capacity. But increasing the linear dimension of generator, the losses will increase with the generator proportional to the cube of linear dimensions, resulting in a serious decline in generator efficiency. Therefore, reducing the temperature rise is very important [5~7]. The waste heat produced by control inverter. The heat of control inverter mainly comes from the electronic component with impedance, such as capacitors, thyristor, SCR. When the current through the impedance will convert part of the electrical energy into heat energy. Inverter prone to failure by power unit over-temperature, such as the control inverter working environment temperature increased every 10,will make control inverter life reduced by half, while greatly increasing failure rate. Therefore, the heat problem of inverter determines that inverter is working properly, in order to prevent temperature of the various components of the power unit is too high [8]. The cooling technology of wind turbine Wind turbine cooling technology can be divided for air cooling system and liquid cooling system. And air cooling system can be divided into natural ventilation cooling and forced air cooling. According to statistics, about 95% of the wind turbine using forced air cooling and liquid cooling [9]. The cooling technology commonly used at present in Tab.1 [10]. Table 1 Comparison of several cooling technology Cooling technology Cooling medium Volume Cost Cooling capacity Service Cooling life efficiency air-air air big low small short low liquid-air lubricating oil small low medium medium medium air-liquid-air antifreeze medium medium big medium high liquid-liquid-air antifreeze medium medium big medium high air-liquid-liquid antifreeze medium medium big medium high centralized cooling Water or air big high big long medium Air-air cooling technology. Air-air cooling technology is the outside cold air exchange heat with the hot air by natural air convection or forced air convection so as to cool the components. No cooling equipment is add in nature ventilation cooling system which the cold air outside and heated air inside exchanges heat by natural convection. Due to natural convection heat transfer coefficient is small, so it is only suitable for low-power wind turbines. Forced air cooling uses forced air convection, installing a blower or fan inside of the wind turbine, when the air passing the heat surface at a high speed, can destroy the boundary layer and reduce the thermal resistance and increase the convective heat transfer coefficient [8]. Generally, the unit capacity below 300kW, generator and control inverter has small amount of heat dissipation, heat mainly concentrated on the gear box. For generators, cooling fans can be set internal and external. For control inverter, cooling fans also be set in the inverter motor tail or the control cabinet outlet. And a fan is mounted in the high-speed shaft in the gear box, through the gear box shaft rotation drives fan to deliver cold air [3]. In theory, the more air volume and the faster air velocity, the better cooling effect, but the oversized cooling fan will cause generator wind friction loss increases, reducing the efficiency of the generator. Air-air cooling technology m is simple, the initial investment and operating costs are low, and easy to maintenance and management. But the cooling effect is influenced by the external environment, such as temperature, weather change, etc., with big restriction and small cooling capacity. Air circulation 1799
3 process will cause the corrosion problem of the cabin interior equipment, as well as by the impact of space heat and temperature distribution is not uniform and cause material deformation [11]. Liquid-air cooling technology. The waste heat transfers to circulate liquid coolant first in liquid-air cooling technology, then exchanges heat with the outside high speed forced convection air in a heat exchanger, after the coolant cools down and back to the internal equipment. Now most gear boxes use liquid-air cooling technology. When the capacity is more than 300kW, power dissipation greatly increases in gear box so as to forced air cooling cannot solve waste heat problem, and the only way is the lubricating oil circulating system which has a better cooling capacity. When the turbine runs at high speed, the heat will be taken away by the lubricating oil which pressurized by a mechanical pump into the heat exchanger, after the high speed air flowing through the other side of the heat exchanger to cool the oil that will back to the gear box (Fig.1). And it is different from the finned tube heat exchanger used by air-air cooling, to enhance heat transfer effect, aluminum plate-fin heat exchanger is widely used, which has small volume, light weight, high thermal efficiency, strong adaptability, and the heat transfer capacity of per unit volume is ten times than finned tube heat exchanger. Fig.1 Liquid-air cooling technology Fig.2 Air-liquid-air cooling technology Liquid-air cooling technology uses in high capacity wind turbine, whose structure is more complex. Due to the increase of the heat exchanger and the coolant, it rises the initial investment and maintenance costs. But its cooling effect improves significantly. Although the main components of the wind and rain erosion solves, but the corrosion problem of the heat exchanger comes. Due to plate-fin heat exchanger small volume and high efficiency, it can effectively solve the uneven distribution of heat and temperature problems, and reduce wind abrasion and improve efficiency. Air-liquid-air cooling technology. As the capacity of wind turbine is increasing, air-air cooling technology and liquid-air cooling technology are not enough to cooling load. Therefore higher heat transfer efficiency of air-liquid-air cooling technology is introduced. Air-liquid-air cooling technology means that the heat generated by the device is cooled by the coolant through two heat exchangers. For example, hot air in generator first exchanges heat with the circulating coolant A in the first heat exchanger, then the circulating coolant B with large heat flows to the second heat exchanger outside the engine cabin, and exchanges heat with external high-speed flow air by forced convection. After cooling, the coolants back to the generator to continue the next cycle (Fig.2). Now commonly used as coolant is antifreeze, mainly glycol water solution. The addition of stabilizers and preservatives make the coolant has a close thermal performance as water, but also has better freezing properties, when the volume concentration of 60%, with the lowest freezing point -50.1, which can meet the requirements of low-temperature unit [12]. Air-liquid-air cooling technology adds a cooling system and makes the structure more complex. Also the initial investment and maintenance costs significantly increased. But it has greater cooling capacity and efficiency. So no sand and water erosion problem, it provides the wind turbine a favorable working environment and extend its life. The structure is complex, but more compact, and a moderate volume between air-air cooling and liquid-air cooling. Liquid-liquid-air cooling technology. Liquid-liquid-air cooling technology and air-liquid-air cooling technology are similar. Also heat is exchanged by the circulating coolant in two runs, except liquid instead of air in the first run. For MW wind turbine, the waste heat of gear box surges, even liquid-air cooling is not enough. Then it is cooled by liquid-liquid-air that provides better heat transfer. Hot lubricating oil is pushed into the first liquid-liquid heat exchanger by mechanical pump, and cooled by 1800
4 intermediate coolant. Then the intermediate coolant is circulated to the liquid-air heat exchanger which is cooled by the high-speed air by forced convection (Fig.3). Because it is similar to the air-liquid-air cooling, whose coolant is antifreeze, glycol water solution is often used. Liquid-liquid-air cooling technology is suitable for wind turbines with high-power gear box. Its structure similar as air-liquid-air cooling, but the initial investment and maintenance increased. However, heat change mediums in the first heat exchanger are both liquid, so the heat transfer coefficient of liquid and liquid is much greater than air and liquid, therefore a large cooling capacity. There is no sand and water erosion problems, so the equipment life will extend effectively. Fig.3 Liquid-liquid-air cooling technology Fig.4 Evaporation cycle cooling technology Air-liquid-air cooling technology. Air-liquid-liquid cooling technology is also known as evaporation cooling cycle technology [13]. And an evaporation cycle cooler is set in the extravehicular of wind turbines that intermediate circulating coolant is no longer simply using forced air, but by the special arrangement of the cooling system for cooling through evaporation and condensation processes. Evaporation cycle cooler may be disposed in the rear cabin, also can be placed on the top of the nacelle to reduce its weight [14], as shown in Fig.4. Air-liquid-liquid cooling technology is used in high-power wind turbine. The evaporation cycle refrigerator cooling effect is better, but the refrigerator will increase the cost of the initial investment and the operating power is far greater. Thereby it has a worse power generation efficiency. To enhance the effect of heat transfer, the refrigerator should be placed outside the nacelle, so wind and rain erosion problems inevitably, but require regular maintenance, and the life is short. Centralized cooling technology. Centralized cooling technology is different from the single cooling unit, which has a center cooling unit in the whole wind farm to provide cooling capacity for each wind turbine. The heat of gear box, generator and control inverter is still taken away by their external heat exchanger with the refrigerant. Then the coolant which has a higher temperature flows back to the center cooling unit to reduce the temperature. After cooling to designed temperature, the coolant is delivered by circulating pump to each unit. To avoid sand and rain erosion, the coolant and the recycling pipeline are generally fixed together with the electric cable in the tower interior (Fig.5). The coolant can be water or air. But the height of the tower is often ten meters to hundred meters, if water is chose as the coolant, although thermal effect is better, but more power is needed to pump it. Both from the economic and energy utilization aspects, it produces huge energy losses [15]. Centralized cooling technology can be regulated according to cooling capacity changes by equipment requirements and seasons. So it has strong flexibility and wide range. However, this cooling system needs long pipelines laid in the wind farm, not only refrigerant and pipe material cost more, but also the energy consumption of pump is huge and maintenance is difficult. 1801
5 The new wind turbine cooling technology Throughout the above cooling technologies, there are some problems. Due to the increased unit capacity, cooling equipment not only makes the efficiency decreased and costs increased, but also brings corrosion problems. In recent years, heat pipe cooling technology is intensive researched, which has excellent thermal conduction, heat flux variability, reversible flow direction, constant temperature properties, good environment adaptability, compact structure and low cost, etc.. If heat pipe is used to instead of the usual heat exchanger, not only high heat transfer rate can be required, but also corrosion problems and initial investment and maintenance cost will be effectively reduced. Fig.5 Centralized cooling technology Fig.6 Heat pipe cooling technology The heat pipe is made up of shell and wick and end cap. A negative pressure within the pipe which is filled with a proper amount of working medium. Heat pipe is divided into three sections: the evaporator section, adiabatic section and condenser section. The working medium is evaporated by hot resource in the evaporator section, thus there is a slight pressure difference at both ends. Working medium (gas) will pass through adiabatic section to condenser section with lots of heat by the pressure difference. Then the gas condensates to liquid in the condenser section and conducts heat to environment. Finally the liquid will flow back to the evaporator section by gravity. Heat pipe transfers heat with the phase change and its thermal capacity is more than any known metal, which has a very high heat transfer efficiency and excellent cooling effect [8, 16]. Many substances can be used as working medium in heat pipe, such as water, ammonia, methanol, acetone, R11, R113 and so on. So the most widely used is water, the scope of work is 30~200 [17]. Therefore, improvements are made as follows: intermediate cooling medium is cooled by heat pipe, this can increases the efficiency of cooling and reducing the cost and size of the volume (Fig.6). New cooling system is not only suitable for high-capacity wind turbine, but also its structure is greatly simplified, so its size and maintenance and operation cost. This system has low energy consumption and high efficiency. Conclusion The continuous development of high-power wind turbine makes the unit capacity of wind turbines increasing a lot, but this brings challenges to the cooling technology. The current advantages and disadvantages of the commonly used cooling technologies are summarized. So the new cooling technology with gravity heat pipe has designed to instead. The new technology has higher heat transfer efficiency, simpler structure, lower initial and operation costs. So it will be widely used in wind turbine cooling system. 1802
6 Acknowledgement The authors gratefully acknowledge the support by Teaching Reform Project (2015-JPBKY-030) of University of Shanghai for Science and Technology. References [1] Weiwei Yuan, Study on the cooling system of wind power generation, Nanjing: Nanjing University of Aeronautics and Astronautics, [2] Jian Zhang, Ruiqing Liu, Discuss of the gear box of wind turbine generator, Wind power, 2004, 72(1): [3] Daguang Wang. Thermal power calculation of gearbox for electric speed, Wind power, 2003, 15(3): [4] Shunnian Ding, Heating and cooling of large motor, Science Press, Beijing, [5] Yunqiu Tang, Nai Shi, Electrical machinery, China Machine Press, Beijing, [6] Tianjun Ni, Main Cooling mode and characteristics of large generator. Dongfang Electric Review, 2006, 20(1): [7] Tskhvirashvili D.G., Berishvili Z.D., Keshelava V.G., Tsagareli K., Experience in operating the water-cooling system of the generator stator windings at the inguri hydroelectric station, Power Technology and Engineering (Formerly Hydro Technical Construction), 1990, 24(8): [8] Helun Dong, Choice and performance of high-voltage inverter radiator, Fuxin: Liaoning University of Engineering and Technology, [9] Zhou Dao, Frede Blaabjerg, Mogens Lau, Michael Tonnes, Thermal profile analysis of double-fed induction generator based wind power converter with air and liquid cooling methods, Power Electronics and Applications, 2013, 15:1-10. [10] Bin Yuan, Yuhong Shen, Duo Zong, Research on cooling systems in high-power wind turbine, Dongfang Turbine, 2012, 4:6-9. [11] Zhili Liu, Design and experimental study of large-scale wind power generator cooling system, Ningjing: Nanjing University of Aeronautics and Astronautics, [12] Zhicheng Tan, Glycol and water binary system of physical and chemical properties data, Chemical Engineering (China), 1983(1): [13] Yanlong Jiang, Weiwei Yuan, Hualin Li, Wind turbine generator with evaporative cooling system. Patent application No [14] Wang Li, Haifeng Wang, Steady-state thermal simulation of the stator coil of the evaporative inner cooling system in wind turbines, Information and Automation for Sustainability, 2012: [15] Yanlong Jiang, Weiwei Yuan, Hualin Li, Centralized cooling wind generator system, Patent application No [16] Tianrong He, Heat pipe technology and its application in thermal engineering, Industrial Boilers, 2003, 78 (2): [17] David Reay, Peter Kew, Ryan Mc Glen. Heat Pipes (Theory, Design and Applications). Oxford: Elsevier Ltd, 2014:
How To Understand Evaporator
SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES After studying this unit, the reader should be able to Define high-, medium-, and low-temperature refrigeration.
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences
A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.
A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities. Richard L. Dornfeld, BSME, P.E. Staff Engineer September 25, 2014 Moisture can be a problem
The Second Law of Thermodynamics
Objectives MAE 320 - Chapter 6 The Second Law of Thermodynamics The content and the pictures are from the text book: Çengel, Y. A. and Boles, M. A., Thermodynamics: An Engineering Approach, McGraw-Hill,
Two-Phase Evaporative Precision Cooling Systems
Two-Phase Evaporative Precision Cooling Systems For heat loads from 3 to 300kW Using non-conductive refrigerant fluid, our patented Next-generation, two-phase evaporative precision cooling systems enable
Vapor Chambers. Figure 1: Example of vapor chamber. Benefits of Using Vapor Chambers
Vapor Chambers A vapor chamber is a high-end thermal management device that can evenly dissipate heat from a small source to a large platform of area (see Figure 1). It has a similar construction and mechanism
Crowne Plaza Copenhagen Towers The world s greenest hotel
Crowne Plaza Copenhagen Towers The world s greenest hotel The new Crowne Plaza Copenhagen Towers in Copenhagen, has been designed with sustainability in top of mind. The hotel is one of the first hotels
HEATER, AIR CONDITIONING AND VENTILATION
55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT
Why Daikin? 2015 Houston, Texas USA www.daikincomfort.com
Why Daikin? Daikin: The Premium Brand industry leader Daikin is recognized as the world s number one leader in the manufacture of HVAC equipment and refrigerants. For over 90 years, Daikin has grown consistently
Chilled Water HVAC Systems
Chilled Water HVAC Systems By Ron Prager, Brinco Mechanical Services, Inc. Types of water based systems: There are three types of HVAC systems that utilize water as a heat transfer medium. The first system,
KINETIC ENERGY RECOVERY SYSTEM BY MEANS OF FLYWHEEL ENERGY STORAGE
ADVANCED ENGINEERING 3(2009)1, ISSN 1846-5900 KINETIC ENERGY RECOVERY SYSTEM BY MEANS OF FLYWHEEL ENERGY STORAGE Cibulka, J. Abstract: This paper deals with the design of Kinetic Energy Recovery Systems
EFFICIENT ELECTRICAL ENERGY TRANSMISSION AND DISTRIBUTION INTERNATIONAL ELECTROTECHNICAL COMMISSION
EFFICIENT ELECTRICAL ENERGY TRANSMISSION AND DISTRIBUTION INTERNATIONAL ELECTROTECHNICAL COMMISSION EFFICIENT ELECTRICAL ENERGY TRANSMISSION AND DISTRIBUTION 1 EFFICIENT ELECTRICAL ENERGY TRANSMISSION
Heat Pipe Cooling of Concentrating Photovoltaic (CPV) Systems
Heat Pipe Cooling of Concentrating Photovoltaic (CPV) Systems William G. Anderson 1, Sanjida Tamanna 2, David B. Sarraf 3, and Peter M. Dussinger 4 Advanced Cooling Technologies, Inc., Lancaster, PA, 17601
Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"
Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A" Takahiro OUE *1, Kazuto OKADA *1 *1 Refrigeration System & Energy Dept., Compressor Div., Machinery Business Kobe Steel has developed an air-sourced
Heat Pipe Selection Revision 12/04/2001
Heat Pipe Selection Revision 12/04/2001 Heat pipes are being used very often in particular applications when conventional cooling methods are not suitable. Once the need for heat pipe arises, the most
Glossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur
Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur Lecture No. # 22 Refrigeration System Components: Compressor (Continued)
ENERGY TRANSFER SYSTEMS AND THEIR DYNAMIC ANALYSIS
ENERGY TRANSFER SYSTEMS AND THEIR DYNAMIC ANALYSIS Many mechanical energy systems are devoted to transfer of energy between two points: the source or prime mover (input) and the load (output). For chemical
How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.
Demystifying HVAC Test Your HVAC Knowledge By Ron Prager How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page. 1)
Mechanical shaft seal types and sealing systems
Chapter 2 Mechanical shaft seal types and sealing systems 1. Mechanical shaft seal types 2. Sealing systems 3. Selecting a mechanical shaft seal Mechanical shaft seal types and sealing systems 1. Mechanical
Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures
Data Realty Colocation Data Center Ignition Park, South Bend, IN Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures Project Overview Data Realty is a data center service provider for middle
Chapter 3.4: HVAC & Refrigeration System
Chapter 3.4: HVAC & Refrigeration System Part I: Objective type questions and answers 1. One ton of refrigeration (TR) is equal to. a) Kcal/h b) 3.51 kw c) 120oo BTU/h d) all 2. The driving force for refrigeration
DOWFROST GEO 20: Propylene Glycol-Based Heat Transfer Fluid for Geothermal Heat Pump Systems
DOWFROST GEO 20: Propylene Glycol-Based Heat Transfer Fluid for Geothermal Heat Pump Systems Geothermal coils eight feet underground. This is the end of a system used to heat and cool a large residential
The Second Law of Thermodynamics
The Second aw of Thermodynamics The second law of thermodynamics asserts that processes occur in a certain direction and that the energy has quality as well as quantity. The first law places no restriction
Optimization Design for Sulfur Dioxide Flow Monitoring Apparatus in Thermal Power Plants Hao-wei Hu 1, a, Xue Yang 1, b and Xiao-wei Song 1, c
International Conference on Information Sciences, Machinery, Materials and Energy (ICISMME 2015) Optimization Design for Sulfur Dioxide Flow Monitoring Apparatus in Thermal Power Plants Hao-wei Hu 1, a,
LESSON 1. HEAT EXCHANGERS
LESSON 1. HEAT EXCHANGERS 1 Contents (I) Definition. Classification. Regenerators. Mixers or direct contact heat exchangers. Packed bed heat exchangers (Intercambiadores de lecho compacto). Direct flame
5. State the function of pulveriser. The pulverisers are the equipments which are used to powdered coal.
413 POWER PLANT ENGINEERING PART-A 1. Define Power. Power is the rate at which energy is used (or) Energy/time. 2. What are the types of fuels? Solid fuel Liquid fuel Gaseous fuel (Any one among the above
GEOTHERMAL POWER GENERATION A PRIMER ON LOW-TEMPERATURE, SMALL-SCALE APPLICATIONS
GEOTHERMAL POWER GENERATION A PRIMER ON LOW-TEMPERATURE, SMALL-SCALE APPLICATIONS by Kevin Rafferty Geo-Heat Center January 2000 REALITY CHECK Owners of low-temperature geothermal resources are often interested
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
Il Peso del Thermal Management nei LED
Il Peso del Thermal Management nei LED Heat Pipe: high performance thermal solution Ing. Manca Claudio F.lli POLI S.r.l. Padova 10-12 Ottobre 2013 Titolo Intervento 1/N Heat pipes in the history The Heat
Drives and motors. A guide to using variable-speed drives and motors in retail environments
Drives and motors A guide to using variable-speed drives and motors in retail environments Improving energy efficiency and lowering the carbon footprint Retailers across the UK take their corporate responsibility
Energy Savings through Electric-assist Turbocharger for Marine Diesel Engines
36 Energy Savings through Electric-assist Turbocharger for Marine Diesel Engines KEIICHI SHIRAISHI *1 YOSHIHISA ONO *2 YUKIO YAMASHITA *3 MUSASHI SAKAMOTO *3 The extremely slow steaming of ships has become
جامعة البلقاء التطبيقية
AlBalqa Applied University تا سست عام 997 The curriculum of associate degree in Air Conditioning, Refrigeration and Heating Systems consists of (7 credit hours) as follows: Serial No. Requirements First
International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS
International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU Technical Paper (13 December 2013) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES
Heat-Pipe Heat Exchanger
Heat-Pipe Heat Exchanger Heat Pipe Heat Exchanger For air-air 1 Heat Pipe Heat Exchanger Heat exchanger, which transfers the heat from one medium to another, is the most common thermal equipment in various
Motor-CAD Software for Thermal Analysis of Electrical Motors - Links to Electromagnetic and Drive Simulation Models
Motor-CAD Software for Thermal Analysis of Electrical Motors - Links to Electromagnetic and Drive Simulation Models Dave Staton, Douglas Hawkins and Mircea Popescu Motor Design Ltd., Ellesmere, Shropshire,
How To Save Energy With High Pressure Control
Energy savings in commercial refrigeration equipment : High Pressure Control July 2011/White paper by Christophe Borlein AFF and IIF-IIR member Make the most of your energy Summary Executive summary I
01-3 6820-11 6820-11 AIR CONDITIONER GENERAL 1. SPECIFICATIONS AIR CONDITIONER REXTON 2010.01
682011 013 GENERAL 1. SPECIFICATIONS 682011 014 682011 2. REPAIR INSTRUCTIONS 1) Precautions for Working with R134a R12 refrigerant and R134a refrigerant are not compatible. These refrigerants must never
Investigation into the energy consumption of a data center with a thermosyphon heat exchanger
Article Mechanical Engineering July 2011 Vol.56 No.20: 2185 2190 doi: 10.1007/s11434-011-4500-5 SPECIAL TOPICS: Investigation into the energy consumption of a data center with a thermosyphon heat exchanger
Low Profile Unit Cooler
Super-Flo Now available with EC Motors High Efficiency / High Reliability Low Profile Unit Cooler Publication No. 411.4 November, 2008 S A N I T A T I O N F O U N D A T I O N A L N A T I O N Air Defrost
Thermal Modeling and Analysis of a Wind Turbine Generator
Thermal Modeling and Analysis of a Wind Turbine Generator Authors: Dr Bogi Bech Jensen (Associate Professor) Technical University of Denmark Mathew Lee Henriksen (PhD student) Technical University of Denmark
Questions to be responded to by the firm submitting the application. Why do you think this project should receive an award? How does it demonstrate:
Questions to be responded to by the firm submitting the application Why do you think this project should receive an award? How does it demonstrate: innovation, quality, and professional excellence transparency
Yijun Gao, Wei Wu, Zongwei Han, Xianting Li *
Study on the performance of air conditioning system combining heat pipe and vapor compression based on ground source energy-bus for commercial buildings in north China Yijun Gao, Wei Wu, Zongwei Han, Xianting
Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE
Hot Water Boilers and Controls Why Condensing Boilers are Different Presented Oct. 14, 2008 Long Island Chapter, ASHRAE H.W. Boilers and Controls Major types of boilers Advantages and disadvantages Resistance
How Ground/Water Source Heat Pumps Work
How Ground/Water Source s Work Steve Kavanaugh, Professor Emeritus of Mechanical Engineering, University of Alabama Ground Source s (a.k.a. Geothermal s) are becoming more common as the costs of energy
1150 hp motor design, electromagnetic and thermal analysis
115 hp motor design, electromagnetic and thermal analysis Qasim Al Akayshee 1, and David A Staton 2 1 Mawdsley s Ltd., The Perry Centre, Davey Close, Waterwells, Gloucester GL2 4AD phone: +44 1452 888311
COMMON EQUIPMENT FAILURES AND CAUSES. How breakdowns can impact the bottom line. A handy reference guide from Hartford Steam Boiler.
COMMON EQUIPMENT FAILURES AND CAUSES How breakdowns can impact the bottom line. A handy reference guide from Hartford Steam Boiler. A WORLD THAT DEPENDS ON EQUIPMENT. Businesses, institutions and municipalities
Comparison of Heat Transfer between a Helical and Straight Tube Heat Exchanger
International Journal of Engineering Research and Technology. ISSN 0974-3154 Volume 6, Number 1 (2013), pp. 33-40 International Research Publication House http://www.irphouse.com Comparison of Heat Transfer
COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.
COIL INPUT SCREENS Example of a Water Coil Input Screen: (*please see the appendix for an example of an Evaporator, Steam or Condenser Coil input screen) PHYSICAL DATA ITEM NUMBER: Always use a 1 through?
Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany
Life Cycle Costing Analysis of Water-cooled Chillers Chillventa Nuremburg, Germany Spring 2012 Description Life Cycle Cost Analysis is a method of determining and comparing the total costs of investment
How To Use A Water Source Heat Pump
Geothermal Energy Using Water-Source Heat Pumps By VIRSTAR Corporation Geothermal Expertise Since 1978 All information contained herein is the exclusive property of VIRSTAR Corporation, all rights reserved.
Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard
Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Introduction SRU s (Sulfur Recovery Units) are critical pieces of equipment in refineries and gas plants. SRUs remove sulfur compounds from certain
Energy Transformations
Energy Transformations Concept Sheet Energy Transformations PS.6: The student will investigate and understand states and forms of energy and how energy is transferred and transformed. 1. Energy is the
Computational Fluid Dynamic Investigation of Liquid Rack Cooling in Data Centres
School of something School of Mechanical Engineering FACULTY OF OTHER ENGINEERING Computational Fluid Dynamic Investigation of Liquid Rack Cooling in Data Centres A. Almoli 1, A. Thompson 1, N. Kapur 1,
Lesson 36 Selection Of Air Conditioning Systems
Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section
Refrigeration Basics 101. By: Eric Nelson
Refrigeration Basics 101 By: Eric Nelson Basics Refrigeration is the removal of heat from a material or space, so that it s temperature is lower than that of it s surroundings. When refrigerant absorbs
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries Hot tips and cool ideas to save energy and money! Air conditioning units or systems are often used by foundries
Product Data Bulletin
Product Data Bulletin Adjustable Frequency Drives and HVAC Systems An Application Guide September, 1994 Raleigh, NC, U.S.A. INTRODUCTION All buildings pose the same problem: how to heat or cool the air
Name: Class: Date: 10. Some substances, when exposed to visible light, absorb more energy as heat than other substances absorb.
Name: Class: Date: ID: A PS Chapter 13 Review Modified True/False Indicate whether the statement is true or false. If false, change the identified word or phrase to make the statement true. 1. In all cooling
Ground Source Heat Pumps The Fundamentals. Southington, Connecticut 860 628 4622 John F. Sima III P.E.
Ground Source Heat Pumps The Fundamentals Southington, Connecticut 860 628 4622 John F. Sima III P.E. Winter/Spring 2010 Ground Source Heat Pumps The Fundamentals TOPICS: Heat Pump Terminology Basic Physics
Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets
2 Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets - Extending Use of New Heat Pump System in Cold Regions
Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling
Water Fired Chiller/Chiller-Heater WFC-S Series: 1, 2 and 3 RT Cooling W E A R E F R I E N D L Y T O T H E E A R T H Water Fired SINGLE-EFFECT Chiller or Chiller-Heater Absorption Principle Cooling Cycle
imagine SOLAR AIR CONDITIONING MADE EASY
imagine SOLAR AIR CONDITIONING MADE EASY WHY SOLAR COOLING? Imagine...being able to fit a solar air conditioning system to your building that would result in dramatic reductions in electricity consumption
Calculation of Temperature in a Large Turbine Generator with Multilayer Roebel Transposition Coils
Calculation of Temperature in a Large Turbine Generator with Multilayer Roebel Transposition Coils Kenichi Hattori *, Kazuhiko Takahashi, Kazumasa Ide, Keiji Kobashi, Hiroshi Okabe, and Takashi Watanabe
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
Generating Current Electricity: Complete the following summary table for each way that electrical energy is generated. Pros:
P a g e 1 Generating Current Electricity: Complete the following summary table for each way that electrical energy is generated. Generating Electrical Energy Using Moving Water: Hydro-Electric Generation
DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS
DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS J J Brasz, Carrier Corporation, Syracuse, NY, 13221, USA [email protected] I K Smith and N Stosic
INFO HTK. Hybrid dry cooler. The reference for hybrid dry cooling. 100 4,000 kw
INFO HTK Hybrid dry cooler The reference for hybrid dry cooling 4, kw JAEGGI The Original Since 929, JAEGGI has been engaged in the development, production and sale of heat exchangers. Since 995, the company
Passive Cooling Systems Air Conditioning Without the Need of Energy
Passive Cooling Systems Air Conditioning Without the Need of Energy 1 Introduction and Abstract PCS Shelter for ADCO SAS project in the UAE/Sahil and Shah Pipe Lines and Supply Networks often run through
525-MVA Generator-motor and Thyristor Starter Put into Service at the Tokyo Electric Power Co., Inc. s Kannagawa Hydroelectric Power Station
525-MVA Generator-motor and Thyristor Starter Put into Service at the Tokyo Electric Power Co., Inc. s Kannagawa Hydroelectric Power Station 114 525-MVA Generator-motor and Thyristor Starter Put into Service
COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers
COMMERCIAL HVAC CHILLER EQUIPMENT Air-Cooled Chillers Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application topics. They
ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM
ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM J.S. Hu, Philip C.W. Kwong, and Christopher Y.H. Chao Department of Mechanical Engineering, The Hong Kong University of Science and Technology Clear Water Bay,
State of the Art Energy Efficient Data Centre Air Conditioning
- White Paper - State of the Art Energy Efficient Data Centre Air Conditioning - Dynamic Free Cooling - Release 2, April 2008 Contents ABSTRACT... 3 1. WHY DO I NEED AN ENERGY EFFICIENT COOLING SYSTEM...
Dynamic Process Modeling. Process Dynamics and Control
Dynamic Process Modeling Process Dynamics and Control 1 Description of process dynamics Classes of models What do we need for control? Modeling for control Mechanical Systems Modeling Electrical circuits
Station #1 Interpreting Infographs
Energy Resources Stations Activity Page # 1 Station #1 Interpreting Infographs 1. Identify and explain each of the energy sources (5) illustrated in the infograph. 2. What do the white and black circles
AIR CONDITIONING TECHNOLOGY
AIR CONDITIONING TECHNOLOGY PART 9 Water Cooled Condensers & Cooling Towers IN LAST month s article we looked at how Air Cooled Condensers are used to transfer the total heat of rejection from the air
Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling
Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling Joshua Grimshaw Director of Engineering, Nova Corporation
Electric Coolant Pumps. Always at the Correct Temperature
Electric Coolant Pumps Always at the Correct Temperature Electric coolant pumps Conventional pumps for engine cooling are driven by toothed belts and hence their output is coupled to engine RPM. Coolant
In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil
In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil Answer: (1) Condenser coil See the video. A.R.E. Building Systems Study Guide
MEETING AGENDA. Project Administrator:
MEETING AGENDA Project Administrator: To: Ann Green M. Baker, SLCS C. Bullinger, SLCS R. Clark, SLCS Board C. Cox, SLCS S. Dotinga, Granger J. Graham, SLCS J. Gusick, SLCS, Board C. Hanshaw, SLCS Board
Dr.A.K.Shaik Dawood. N.V.Kamalesh. Department of Mechanical Engineering, Associate Professor, Karpagam University, Coimbatore 641202, India.
CFD Analysis of cooling channels in built-in motorized high speed spindle K.MadhanMuthuGanesh Department of Mechanical Engineering, Research scholar, PSG College of Technology, Coimbatore 641107, India.
High Density Data Centers Fraught with Peril. Richard A. Greco, Principal EYP Mission Critical Facilities, Inc.
High Density Data Centers Fraught with Peril Richard A. Greco, Principal EYP Mission Critical Facilities, Inc. Microprocessors Trends Reprinted with the permission of The Uptime Institute from a white
Waste Heat Recovery through Air Conditioning System
International Journal of Engineering Research and Development e-issn: 2278-067X, p-issn : 2278-800X, www.ijerd.com Volume 5, Issue 3 (December 2012), PP. 87-92 Waste Heat Recovery through Air Conditioning
Integrated Solar Radiant Systems
Integrated Solar Radiant Systems William Shady PE President Topics Radiant heating Indoor air quality Radiant Cooling Project Photos Questions and answers The goal for our clients Healthy Comfort Why Radiant
Basics of Electricity
Basics of Electricity Generator Theory PJM State & Member Training Dept. PJM 2014 8/6/2013 Objectives The student will be able to: Describe the process of electromagnetic induction Identify the major components
THE CASE FOR A REFRIGERATION PREVENTATIVE MAINTENACE PROGRAM
THE CASE FOR A REFRIGERATION PREVENTATIVE MAINTENACE PROGRAM Prepared and Presented By: Don Langston President & CEO, Aire Rite Air Conditioning & Refrigeration Inc Setting the Foundation The Refrigeration
16. Heat Pipes in Electronics Cooling (2)
16. Heat Pipes in Electronics Cooling (2) 16.1 Pulsating Heat Pipes 16.1.1Introduction Conventional heat pipe technology has been successfully applied in the last thirty years for the thermal management
Variable Capacity Compressors, a new dimension for refrigeration engineers to explore
Variable Capacity Compressors, a new dimension for refrigeration engineers to explore By: Marcos G. Schwarz, VCC Group Leader Corporate Research & Development, EMBRACO SA Abstract: This paper presents
The Different Types of Air Conditioning Equipment for IT Environments
The Different Types of Air Conditioning Equipment for IT Environments By Tony Evans White Paper #59 Executive Summary Cooling equipment for an IT environment can be implemented in 10 basic configurations.
How air conditioning works
1 How air conditioning works The essential ingredients in an air conditioning system are a fan to blow air around, a cold surface to cool and dehumidify the air, a warm surface and a source of water vapour.
Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty
Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp
understanding medium frequency induction melting furnace and its components
understanding medium frequency induction melting furnace and its components 9 Spruce Street, Jersey City, NJ 07306 USA [email protected] INDUCTION MELTING FURNACE AND ITS COMPONENTS The purpose
Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2008 Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications
LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_071015. Products that provide lasting solutions.
LH and GH/GL Series UNIT COOLERS Technical Bulletin: LHGH_001_07101 Products that provide lasting solutions. LH Series Unit Coolers Dual Discharge Low Hite Series At 9 1/ maximum height, the LH Series
GEOTHERMAL HEATING AND COOLING INTRODUCTION
GEOTHERMAL HEATING AND COOLING INTRODUCTION Geothermal Heating and Cooling Systems provide space conditioning -- heating, cooling, and humidity control. They may also provide water heating -- either to
MUELLER FALLING FILM CHILLERS
MUELLER FALLING FILM CHILLERS MUELLER FALLING FILM CHILLERS ARE DESIGNED TO COOL ANY FLUID TO WITHIN 2 F OF ITS FREEZE POINT. The primary application for Mueller s falling film chiller is to cool food-grade
Automobile Air Conditioning Primer
Automobile Air Conditioning Primer An air conditioner is basically a refrigerator without the insulated box. It uses the evaporation of a refrigerant, like Freon, to provide cooling. The mechanics of the
Energy savings in commercial refrigeration. Low pressure control
Energy savings in commercial refrigeration equipment : Low pressure control August 2011/White paper by Christophe Borlein AFF and l IIF-IIR member Make the most of your energy Summary Executive summary
