1 Steam oilers Low Water ut-offs are specially designed to protect steam boilers from the hazards of a low water condition. In operation they will interrupt the electrical current to the firing device, if the water in the system drops below the boiler manufacturers minimum safe water level. Our low water cut-offs also provide an additional circuit for a water feeder or a low water alarm, should you desire to install one, for additional protection. How to Select Low Water ut-offs for Steam oilers oiler pressure and the method of installation are the primary factors to consider when selecting a low water cut-off. We recommend that secondary (redundant) Low Water ut-off controls be installed on all steam boilers with heat input greater than 400,000 TU/hour or operating above 5 psi of steam pressure. t least two controls should be connected in series with the burner control circuit to provide safety redundancy protection should the boiler experience a low water condition. Moreover, at each annual outage, the low water cut-offs should be dismantled, inspected, cleaned, and checked for proper calibration and performance. oiler ontrols Maximum Method of Installation low own Valve oiler onnect to the Provided with Pressure irectly into oiler with " Product Size Low Water psi (kg/cm 2 ) oiler Tappings* qualizing Piping Series Required ut-off 5 () X X PS /750/750P X 67 4 No N/ 4 No N/ X 6 Yes No Yes Yes 20 (.4) X Yes Yes 50 (.5) 50 (0.5) X 69 2 No N/ X X 42S Yes No 42S- X 64- Yes Yes X 6 Yes No X 64 Yes No Yes Yes X Yes No X 9/9 Yes No X 50S/50 Yes No X 57S/57 Yes No 250 (8) 4 94/94 4 Yes No X 750-/4 Yes No * Use the tapping designated by the boiler manufacturer for low water cut-off installation. 27

2 oiler ontrols How to Select ontrols STM OILRS Steam Heating oilers are classified as boilers in closed heating systems where all condensate is returned to the boiler. est recommendation for all automatically fired boilers is a feeder cut-off combination. It adds water as needed to maintain a safe operating level, and stands by to interrupt circuit to burner if water level drops into emergency zone. Steam Process oilers are classified as boilers in systems where not all the condensate is returned, and some make-up water is needed. separate feeder and separate cut-off are recommended, so operating levels can be set for the wider differential required in such service. Selection of the correct feeder cut-off combination, or feeder depends upon:. Maximum boiler pressure. 2. ifferential between water supply pressure and the pressure setting of the steam safety valve.. oiler size HOT WTR OILRS est recommendation for all automatically fired boilers is a feeder cut-off combination. It adds water if needed to match the discharge capacity of the relief valve, and stands by to interrupt circuit to burner if water level drops into emergency zone. Selection of the correct feeder cut-off combination, or feeder depends upon:. Maximum boiler pressure. 2. ifferential between water supply pressure and the pressure setting of the safety relief valve.. oiler size oiler Rating TU HP R ond. Lb./Hr, , , ,06 7.5, ,750 0, ,48 2.5, ,25 5 2, , , , , ,875 25,500 86,004, ,200,05,7, ,900,208,9, ,600,80,506, ,00,55,67, ,000,725 onversion actors oiler Horsepower (HP) = Gallons of Water TUH R TUH = = = = R 9 Lbs. of Water 8. R x 240 TUH 240 HP x,479 oiler Steaming Rate (Gallons Per Minute) R GPM = 2000 GPM = (HP) x GPM = GPM = Pounds of condensate per hour = TU 480,000 R x R 4 Water eeders and ombination Water eeders/low Water ut-offs oiler Water eeders and eeder ut- Off ombinations are used to provide automatic operation, and to safeguard steam and hot water boilers against the hazards of a low water condition. feeder cut-off combination mechanically adds water as needed to maintain the required minimum water level, and electrically stops the firing device in case of an emergency. 28

3 How to Select Water eeders (continued) Steam oilers oiler Size Maximum (Mfr. Gross Rating Sq. t. of R) oiler Series haracteristics Pressure *ifferential Pressure psi (kg/cm 2 ) psi (kg/cm 2 ) 0 (.7) 20 (.4) 0 (2.) 40 (2.8) 50 (.5) 60 (4.2) 70 (4.9) Uni-Match or utomatic ired 5 (.0) Heating oilers ll oilers up to 2,000 sq. ft. 0 or utomatic ired 25 (.8) Heating oilers ll oilers up to 5,000 sq. ft. 47 or Heating or 25 (.8) Process oilers ll oilers up to 5,000 sq. ft or utomatic ired 25 (.8) Heating oilers ll oilers up to 5,000 sq. ft. 247 or Heating or 0 (2.) Process oilers ll oilers up to 5,000 sq. ft or utomatic ired 0 (2.) Heating oilers ll oilers up to 5,000 sq. ft. 5 or Heating or 5 (2.5) 8,600 2,000 5,000 7,600 20,000 2,800 2,400 Process oilers 5-2 or utomatic ired 5 (2.5) 8,600 2,000 5,000 7,600 20,000 2,800 2,400 Heating oilers 5S or Heating or 5 (2.5) 0,500 7,500 22,400 26,500 0,000 2,600 5,000 Process oilers 5S-2 or utomatic ired 5 (2.5) 0,500 7,500 22,400 26,500 0,000 2,600 5,000 Heating oilers 5 or Heating or 75 (5.) 8,600,600 4,600 7,000 8,800 20,600 22,00 Process oilers 5-2 or utomatic ired 75 (5.) 8,600,600 4,600 7,000 8,800 20,600 22,00 Heating oilers *ifferential pressure should be based on water supply pressure at boiler, minus pressure setting of steam safety valve oiler ontrols 29

4 Low Water ut-offs lectronic or Hot Water and Steam oilers Series 750 Low Water ut-offs with Remote Sensor or commercial or industrial applications Primary or secondary control on hot water boilers Secondary control (manual reset models only) on steam boilers oiler ontrols Manual reset models meet the requirements of SM Standard S-. If the control is in a low water condition when there is an interruption of power, the control will remain in a low water condition when power is restored. The reset button will need to be pressed when the water level is restored to a level above the probe to allow the burner to fire. Green L power indicating light Red L low water indicating light Test switch 20,000 ohms sensitivity Options: - Manual reset button - 750P-MT model includes P-800 probe - 750P-MT-U model includes P-800-U probe NM enclosure Maximum ambient temperature 20 (49 ) NOW WITH SL-LNING PRO! Series 750 ontrol Unit 750P-MT P-MT-U-20 (Remote sensor must be ordered separately ((see page 72-74) G 750-T uto reset 2 (.9) 750-MT Manual reset 2 (.9) 750P-MT Manual reset and P-800 probe 2.5 (.9) 750P-MT-U Manual reset and P-800-U probe 2.5 (.9) lectrical Ratings Motor Switch Rating (mperes) Voltage ull Load Locked Rotor Pilot uty 20 V V at 240 V or 240 V 50 or 60 Hz G Std. U Std U 6 8 (62) 5 8 (0) (65) 9 6 (40) 6 (78) 2 8 (54) 9 6 (40) 4 4 (20) 0

5 High Water ut-offs lectronic or Steam oilers Model 750-HW-MT-20 The 750-HW-MT-20 control provides continuous protection against a HIGH WTR condition in steam boilers and other water level applications. It can be wired to provide alarm, turn off boiler or turn off water feeder pumps when a HIGH WTR condition occurs. The manual reset function will require the unit be reset after water has dropped below the level of the probe. or commercial or industrial applications Primary or secondary control on hot water boilers Green L power indicating light Red L HIGH WTR indicating light Manual Reset Test switch 20,000 ohms sensitivity NM enclosure Maximum ambient temperature 20 (49 ) Model 750-HW-MT-20 ontrol Unit oiler ontrols (Remote sensor must be ordered separately (see page 72-74) 750-HW-MT Manual reset 2 (.9) lectrical Ratings Motor Switch Rating (mperes) Voltage ull Load Locked Rotor Pilot uty 20 V V at 240 V or 240 V 50 or 60 Hz 6 8 (62) 5 8 (0) (65) 4 (20)

6 oiler ontrols Low Water ut-offs lectronic or Steam oilers New and Improved Series PS-800 Low Water ut-offs or residential and commercial applications lectronic operation New eatures: User-friendly diagnostics - Red low water and shorted probe L - Green power and test L Probe sensitivity: 7,000 ohms No lock out with loss of power if probe is in water elay on Make (OM) feature (5 seconds) elay on reak (O) feature (0 seconds) No blow down of control required when mounted directly into boiler tappings Test button standard on all models Options available include Manual reset xtended barrel and remote sensor models 20 volt and 24 volt models (24 volt models meet NSI specification Z2.a) Power consumption.7 V Provisions to add alarm or automatic water feeder Maximum ambient temperature 20 (49 ) Maximum steam pressure 5 psi ( kg/cm 2 ) Maximum water temperature 250 (2 ) 2 PS Low water cut-off 20V 2.7 (.2) PS-80-M PS w/manual reset 2.7 (.2) PS-80-U PS w/ext. barrel 2.7 (.2) PS-80-M-U PS w/ext. barrel 2.7 (.2) & manual reset PS Low water cut-off 24V 2.7 (.2) PS-802-M PS w/manual reset 2.7 (.2) PS-802-U PS w/ext. barrel 2.7 (.2) PS-802-M-U PS w/ext. barrel 2.7 (.2) & manual reset PS-802-RX PS w/remote sensor 2.7 (.2) Series PS-800 lectrical Ratings NOW WITH SL-LNING PRO! Motor Switch Rating (mperes) Model Voltage ull Load Locked Rotor Pilot uty 24 V 24 V 50 V at 24 V 20 V 20 V V at 20 or 240 V 240 V or 60 Hz G H J K ll U Std SP RX2 U ll RX 4 4 (08) 9 6 (40) 6 (78) 2 8 (54) 8 (5) 2 8 (54) 9 6 (40) 4 (20) 6 (2) 5 6 (48) 8 (5) (7) 7 8 (22) J UTION o not use manual reset models with electric automatic water feeders. ailure to follow this caution can cause flooding and property damage. K G H

7 Low Water ut-offs lectronic or Hot Water oilers New and Improved Series PS-850 Low Water ut-offs or residential, commercial and industrial applications lectronic operation New eatures: User-friendly diagnostics - Red low water and shorted probe L - Green power and test L Higher probe sensitivity: 7,000 ohms No lock out with loss of power if probe is in water No blow down of control required when mounted directly into boiler tappings Test button standard on all models Options available include Manual reset xtended barrel, remote and short probe models 20 volt and 24 volt models (24 volt models meet NSI specification Z2.a) Power consumption.7 V Provisions to add alarm Maximum ambient temperature 20 (49 ) Maximum water pressure 60 psi (.2 kg/cm 2 ) Maximum water temperature 250 (2 ) lectrical Ratings Switch Rating (mperes) Model Voltage ull Load Locked Rotor Pilot uty 24 V 24 V 50 V at 24 V 20 V 20 V V at 20 or 240 V 240 V or 60 Hz Series PS-850 NOW WITH SL-LNING PRO! PS Low water cut-off 20V 2.7 (.2) PS-85-U PS w/extended 2.7 (.2) barrel PS-85-M PS w/manual reset 2.7 (.2) PS-85-M-U PS w/extended 2.7 (.2) barrel & manual reset PS-85-RX PS w/remote probe 2.7 (.2) PS-85-M-RX PS w/remote probe 2.7 (.2) & manual reset PS-85-SP PS w/short probe 2.7 (.2) PS-85-SP-M PS w/short probe 2.7 (.2) & manual reset PS Low water cut-off 24V 2.7 (.2) PS-852-M PS w/manual reset 2.7 (.2) PS-852-SP PS w/short probe 2.7 (.2) PS-852-SP-M PS w/short probe 2.7 (.2) & manual reset G H J K ll U Std SP RX2 U ll RX 4 4 (08) 9 6 (40) 6 (78) 2 8 ( 54 ) 8 (5) 2 8 (54) 9 6 (40) 4 (20) 6 (2) 5 6 (48) 8 (5) 4 (20) (25) (7) 7 8 (22) J K G H oiler ontrols UTION o not use manual reset models with electric automatic water feeders. ailure to follow this caution can cause flooding and property damage.

8 Low Water ut-offs lectronic or Hot Water oilers R-24 Low Water ut-offs NOW WITH SL-LNING PRO! or residential applications ompact size oiler ontrols asy to install and wire utomatic reset feature resumes operation after a power outage when water is on probe Green power on indicating L Red low water indicating L Solid state operation 5,000 ohms probe sensitivity Maximum ambient temperature 20 (49 ) Maximum water temperature 250 (2 ) Maximum water pressure 50 psi (.5 kg/cm 2 ) 5 ft. harness cable included w/- and-s models Model R-24 lectrical Ratings Voltage Power onsumption Load Switching 24 V 2.5 V 2 at 24 V Note: 5 m minimum current draw is required. 4 4 (9) 4 (9) (76) 4 (9) R-24S UWH-R-24S R Residential LWO.7 (.2) R Residential LWO w/harness for atmospheric boilers with aquastats & vent dampers R-24S Residential LWO w/harness for sealed combustion HW boilers with integrated electronic burner controls or aquastats UWH-R Replacement cable for R-24 & () 6-pin harness and () 4-pin harness UWH-R-24-S Replacement cable for R-24 & (2) 2-pin power harness R-24 UWH-R-24 4

9 Low Water ut-offs lectronic or Hot Water oilers R-22- Low Water ut-offs NOW WITH SL-LNING PRO! or residential applications lectronic operation asy to install and wire Red low water indicating L Green power indicating L Now with test button utomatic reset No blow down required 20,000 ohms probe sensitivity Maximum ambient temperature 20 (49 ) Maximum water temperature 250 (2 ) Maximum water pressure 60 psi (.2 kg/cm 2 ) Series R-22- H G oiler ontrols lectrical Ratings Voltage Power Load Switching onsumption 20 V. V 5.8 at 20 V G H 2 4 (70) 5 8 (5) 8 (5) 4 (20) 7 8 (22) 6 (99) 4 6 (8) R Low water cut-off.7 (.78) 5

10 Low Water ut-offs lectronic or Hot Water oilers R-20 Low Water ut-offs oiler ontrols NOW WITH SL-LNING PRO! oiler ontrols or residential and (where codes allow) commercial applications lectro-mechanical operation utomatic reset feature resumes operation after a power outage when water is on probe No blow down required 6,000 ohms probe sensitivity Maximum ambient temperature 20 (49 ) Maximum water temperature 250 (2 ) Maximum water pressure 60 psi (.2 kg/cm 2 ) Series R-20 G lectrical Ratings Voltage Power Load Switching onsumption 20 V 5 V 5.8 at 20 V G 6 8 (62) 5 8 (0) (65) 5 8 (4) 8 (5) 4 (20) 7 8 R Low water cut-off.8 (.7) 6

11 Low Water ut-offs lectronic ombination Low Water ut-off/pump ontrollers for Steam oilers Series 50 Primary and secondary low water fuel cut-off protection and pump control for commercial and industrial steam boilers Motorized valve controller, low water cut-off, and alarm actuators for boilers, vessels and tanks Set points and differentials remain constant throughout pressure range iagnostic features incorporated in the control include: High ambient temperature protection Internal Ls that indicate water position and condition xternal Ls that indicate control activity Replacement head assemblies available for Model 50 and 50S Series upgrade ontrol unit can be mounted remotely from probes djustable 60-second burner-off time delays djustable /4 or -/6 pump differentials HP burner and pump relays NM enclosure Maximum ambient temperature 5 (57 ) Maximum operating pressure 50 psi (0.5 kg/cm 2 ) Maximum operating temperature 66 (85 ) at probes Manual reset models meet the requirements of SM Standard S-. If the control is in a low water condition when there is an interruption of power, the control will remain in a low water condition when power is restored. The reset button will need to be pressed when the water level is restored to a level above the probe to allow the burner to fire. 60,000 ohms probe sensitivity Number Number escription lbs. (kg.) ombination low water 22.9 (0.4) cut-off/pump controller 50-M w/manual reset 22.9 (0.4) w/water column 6.9 (6.7) 57-M w/manual reset 6.9 (6.7) w/alternate tappings 9.0 (7.5) 57-R w/alternate tappings 9.0 (7.5) 57-RM w/alternate tappings 9.0 (7.5) 57-RL w/alternate tappings 9.0 (7.5) 57-RLM w/alternate tappings 9.0 (7.5) Series 57 G H G H J J J J K UT O LVL Series 50 Series (69) 5 6 (286) 6 (52) 4 6 (59) 5 6 (84) G H J (275) 4 8 (05) 7 6 (87) Series (62) (59) (25) L UT-O LVL G H J K L (9) 6 (406) (292) (89) (49) oiler ontrols lectrical Rating and Switch Ratings Supply Probe ull load (mps) Locked Rotor (mps) Pilot uty (V) Motor (HP) Voltage Voltage NO (N), (V) NO (N), (V) NO (N), (V) NO (N), (V) 20 V 5 V 6 (5.8), (4.8), (290), 20 (/4), 20 50/60Hz Maximum 8 (4.9), (7.4), (290), (/2), 240 7

12 Low Water ut-offs Mechanical or Steam oilers Series 6 Low Water ut-offs or residential and commercial low pressure steam boiler applications oiler ontrols or boilers of any steaming capacity djustable X outlet for easy installation ual precision switches for dependable operation of the low water cut-off and alarm or electric water feeder Packless bellows " equalizing pipes and blow down valve required Maximum steam pressure 20 psi (.4 kg/cm 2 ) Series 6 UT-O LVL G lectrical Ratings Motor Switch Rating (mperes) 20 V. mp, 240 V.5 mp Voltage ull Load Locked Rotor Pilot uty 20 V V at V or 240 V G (252) (89) 6 (65) 8 (79) 5 8 (0) Low water cut-off.5 (6.) 8

13 Low Water ut-offs Mechanical or Steam and Hot Water oilers Series 6 Low Water ut-offs or residential, commercial, and industrial applications Heavy duty Includes No. 2 switch Optional manual reset available Maximum boiler pressure 50 psi (.5 kg/cm 2 ) Use with T-4 on hot water systems Series 6 UT O LVL G H J oiler ontrols lectrical Ratings Motor Switch Rating (mperes) 20 V.5 mp Voltage ull Load Locked Rotor Pilot uty 20 V V at 240 V or 240 V 60 Hz G H J 6 (65) (65) 5 5 () 9 8 (28) 8 (79) 0 (267) 5 8 (0) Low water cut-off.5 (6.) w/ float block 5.0 (6.8) 6-M w/float block & manual reset 5.0 (6.8) 6-M w/manual reset 4.0 (6.4) 9

14 Low Water ut-offs Mechanical or Steam and Hot Water oilers Series 64 Low Water ut-offs oiler ontrols or residential, commercial, and industrial boiler applications of any steaming capacity Heavy uty djustable X outlet for easy installation ual precision switches for dependable operation of the low water cut-off and alarm or electric water feeder Packless bellows Optional manual reset available " (25mm) equalizing pipes required Maximum boiler pressure 50 psi (.5 kg/cm 2 ) Use with T-4 on hot water systems SRIS 64 UT-O LVL (252) (65) 6 (65) 8 (79) Model 64- Low Water ut-offs Quick hook-up fittings provided for installation directly into gauge glass tappings G UT-O LVL Model 64- G min. max (66) (252) 4 () (72) 8 (9) 8 (79) Low water cut-off. (5.) w/quick hook-up fittings 8. (8.) w/float block.5 (5.2) 64-M w/manual reset 2.5 (5.7) lectrical Ratings Motor Switch Rating (mperes) Voltage ull Load Locked Rotor Pilot uty 20 V V at V or 240 V 40

15 Low Water ut-offs Mechanical or Steam and Hot Water oilers Series 764 Low Water ut-offs or residential, commercial, and industrial boiler applications of any steaming capacity Heavy duty djustable X outlet for easy installation ual precision switches for dependable operation of the low water cut-off and alarm or electric water feeder Packless bellows 2 " side tapping provided for installation with close nipple Maximum boiler pressure 50 psi (.5 kg/cm 2 ) Series 764 UT O LVL oiler ontrols lectrical Ratings Motor Switch Rating (mperes) Voltage ull Load Locked Rotor Pilot uty 20 V V at V or 240 V (75) 6 (65) 8 (79) Low water cut-off 2.5 (5.7) 4

16 Low Water ut-offs Mechanical or Steam oilers Series 67 Low Water ut-offs or residential and commercial applications or boilers of any steaming capacity K oiler ontrols Quick hook-up fittings provided Lever-operated, full port ball valve for easy blow down djustable X outlet for easy installation ual precision switches for dependable operation of the low water cut-off and alarm or electric water feeder Optional features Low voltage switches for self-generating millivolt circuits Manual reset switch Series 67 G J H Max Swing L M N Large float chamber Maximum steam pressure 20 psi (.4 kg/cm 2 ) K J lectrical Ratings Motor Switch Rating (mperes) Voltage ull Load Locked Rotor Pilot uty 20 V V at V or 240 V Model 67-LQHU (without quick hook-up fittings) G H Max Swing M N G H J K L M N min. max. 6 (65) 4 (56) 4 (45) 4 4 (2) 8 (86) 8 (29) (40) (247) 9 6 (90) 2 (64) 2 6 (7) Low water cut-off 0 (4.5) 67-G for millivolt service 0 (4.5) 67-LQHU without quick hook-up fittings 8 (.6) 67-M w/manual reset 0 (4.5) 42

17 Low Water ut-offs Mechanical or Steam oilers Series 767 Low Water ut-offs or residential and commercial low pressure boiler applications or boilers of any steaming capacity 2 " body tapping for side mounting on boilers Lever-operated, full port ball valve for easy blow down djustable X outlet for easy installation ual precision switches for dependable operation of the low water cut-off and alarm or electric water feeder Large float chamber Maximum steam pressure 20 psi (.4 kg/cm 2 ) Series 767 N J H G P (Max. Swing) K L M oiler ontrols lectrical Ratings Motor Switch Rating (mperes) Voltage ull Load Locked Rotor Pilot uty 20 V V at V or 240 V G H J K L M N P 5 (29.) (86.5) (7) 5 8 (7) (5.9) 5 8 (92) 8 5 (207) 9 6 (246.6) 5 (40) Low water cut-off 8.5 (.9) 4

18 Low Water ut-offs Mechanical or Steam oilers Series 69 uilt-in Low Water ut-offs or residential and commercial low pressure steam boiler applications oiler ontrols or boilers of any steaming capacity or mounting in 2 " boiler side tappings Insertion lengths available in 6-4 8" (0-05mm) Packless bellows djustable X outlet for easy installation ual precision switches for dependable operation of the low water cut-off and an alarm or electric water feeder Optional low voltage switches for self-generating millivolt circuits Series 69 UT-O LVL 2 4 Maximum steam pressure 20 psi (.4 kg/cm 2 ) lectrical Ratings Motor Switch Rating (mperes) Voltage ull Load Locked Rotor Pilot uty 20 V V at V or 240 V Insertion Model Length (05) 69 8 (79) (57) (25) 4 8 (05) 69 4 (45) 469, (0) 8 () 2 9 (24) Number Number escription lbs. (kg) Low water cut-off w/4 8" (05mm).7 (.7) insertion length 69-MV-P w/millivolt switch 4.0 (.8) w/ 8" (79mm) insertion length 4.0 (.8) w/2 4" (57mm) insertion length 4.0 (.8) w/ 4" (45mm) insertion length 4.0 (.8) 69-MV w/millivolt switch 4.0 (.8) w/ 6" (0mm) insertion length 4.0 (.8) w/ 6" (0mm) insertion length 4.0 (.8) w/ 4" tapping 44

19 Low Water ut-offs ombination Low Water ut-off/pump ontrollers for Steam oilers Series 42S Low Water ut-off/pump ontrollers or residential, commercial, and industrial low and medium pressure steam boilers with a separate water column or boilers of any steaming capacity Monel bellows provides corrosion resistance Single pole, single throw snap action switches nclosed junction box protects switches Optional features Quick hook-up fittings Gauge glass connector Maximum pressure 50 psi (.5 kg/cm 2 ) with MRURY R Snap-ction Switches SRIS 42S G UT-O LVL oiler ontrols lectrical Ratings Pump ircuit Rating (mperes) Voltage ull Load Locked Rotor Pilot uty 20 V V at 240 V or 240 V T UT-O LVL Voltage larm ircuit Rating (mperes) mps 20 V 240 V /2 42S 2902 ombination low water cut-off/ 5.5 (7.0) pump controller 42S S w/quick hook-up fittings 2. (9.7) 42S-N S w/glass connector 2. (9.7) MOL 42S- MOL 42S-N Model G 42S 2 4 () (65) (225) 6 (94) 8 (79) 42S- 2 4 () (65) (84-47) 2 4 (45) 8 (79) 42S-N 2 4 () (65) (225) 6 (94) 8 (79) L K J M G G H Q N P UT-O LVL S R Model H J K L M N P Q R S T 42S-N (65) (65) 4 (45) 6 (94) 6 (46) 6 (27) 6 (27) (8) (67) 45

20 Low Water ut-offs Mechanical or Steam oilers Series 50S Low Water ut-off/pump ontrollers or commercial and industrial low or high pressure boiler applications or boilers of any steaming capacity oiler ontrols Monel bellows provides corrosion resistance Snap action switches for high temperature service Single pole, single throw switch for pump control Single pole, double throw switch for low water cut-off and alarm actuation Optional features Manual reset 2 Single pole, single throw switches 2 Single pole, double throw switches loat block SPT threads Maximum pressure 50 psi (0.5 kg/cm 2 ) Series 50S with MRURY R Snap-ction Switches G H J J UT-O LVL or new electronic 50 Series see page 7 Model 50S-M Maximum differential operation Prevents nuisance burner shutdowns in low pressure applications Maximum operating pressure 50 psi (.5 kg/cm 2 ) UT-O LVL or additional information see page 48 lectrical Ratings Pump ircuit Rating (mperes) Voltage ull Load Locked Rotor Pilot uty 20 V V at 240 V or 240 V 50S 7702 ombination low water cut-off/ 24.7 (.2) pump controller 50S S w/float block 24.7 (.2) 50S--M S- w/manual reset 24.7 (.2) 50S-M S w/float block and max. dif (.2) 50S-M-M S-M w/manual reset 24.7 (.2) 50S-M S w/maximum differential 24.7 (.2) 50S-M S w/manual reset 24.7 (.2) 50S-M-M S-M w/maximum differential 24.7 (.2) 58S S w/2 SPT switches 26. (.9) 58S-M S w/manual reset 27. (2.4) 59S S w/2 SPST switches 26.0 (.8) larm ircuit Rating (mperes) Voltage mps 20 V 240 V / (49) (6) 6 (52) 4 (7) G H J 5 6 (84) (252) 4 8 (05) 7 6 (87) 46

21 Low Water ut-offs Mechanical or Steam oilers Series 57S Low Water ut-off/pump ontrollers or residential, commercial and industrial low or high pressure boiler applications or boilers of any steaming capacity Monel bellows provides corrosion resistance loat chamber with integral water column provided `Snap action for high temperature service Single pole, single throw switch for pump control Single pole, double throw switch for low water cut-off and alarm actuation Optional features Manual reset Integral conductance probes for additional levels and greater operating differential-model 57S-RP-M " or 4" equalizing tappings " or 4" tappings for gauge glass/tri-cock installations SPT threads Maximum pressure 50 psi (0.5 kg/cm 2 ) or new electronic 50 Series see page 7 Model 57S-M Maximum differential operation Prevents nuisance burner shutdowns in low pressure applications Maximum operating pressure 50 psi (.5 kg/cm 2 ) or additional information see page 48 lectrical Ratings ut-off and Pump ircuits Rating (mperes) Voltage ull Load Locked Rotor Pilot uty 20 V V at 240 V or 240 V Voltage larm ircuit Rating (mperes) mps 20 V 240 V /2 Series 57S Model 57S-R G J H J G L K J J L 57S S low water cut-off w/water column 9.7 (8.0) 57S-M S w/maximum differential 9.7 (8.0) 57S S w/alternate tappings 9.5 (7.9) 57S--M S- w/manual reset 9.5 (7.9) 57S-M S w/manual reset 9.7 (8.0) 57S-M-M S-M w/maximum differential 9.7 (8.0) 57S-R S w/alternate tappings 42.0 (9.0) 57S-R-M S-R w/manual reset 42.0 (9.0) 57S-RP-M S w/2 integral conductance probes 5.0 (2.) 57S-RL S w/alternate tappings 42.0 (9.0) 57S-RL-M S-RL w/manual reset 42.0 (9.0) Model G H J K L 57S 57S- 4 57S-R 57S-RL 4 8 (9) (59) (25) 4 (298) 6 (406) (292) (89) 4 8 (9) (59) (25) 4 (298) 6 (406) (292) (89) 8 (9) 2 4 (57) (49) 4 (298) 7 (42) (292) (89) 9 6 (45) (89) (49) 4 (298) 7 (42) 2 4 (24) (89) K (49) (49) (59) (59) oiler ontrols 47

22 M Model Setpoints oiler ontrols The bellows on the 50 units are sensitive to pressure. t higher pressures the bellows is stiffer requiring more force to move it. t lower pressures the bellows is more pliable (less stiff) requiring less force to move it. onsequently, the on/off points tend to narrow at lower pressures. (Less distance between on and off). arly versions of the 50 units with mercury bulb switches were able to be adjusted. These units had knurled adjustment screws that could be used to raise, lower or widen the setpoints. lthough the available adjustment was small (usually 6" to 8 " total), it was enough to compensate in the field for lower pressure systems. Later versions of the 50 with mercury bulb switches and all snap switch units are not adjustable in the field. The M models were created to provide a 50 control with factory settings to compensate for the narrowing of setpoints on new and existing installations. On M models the distance between pump off and burner off is increased by approximately 7 6 ". Note that the pump on/off differential on both standard and M models is set at 4". This larger differential is accomplished by lowering the burner off setpoint 8 " below the casting line on M models when setting the burner on/off points at 50 psi. This compensates for the narrowing of the setpoints at lower operating pressures because the burner off point will move upward (closer to the casting line) at lower pressures. Operating Levels Series 50/57 & Series 50S/57S Standard Models /4" ifferential "M" Models PUMP O PUMP ON /8" ifferential urner Off Switch setpoints at 50psi urner Off /6" ifferential 48

23 low own Piping SRIS 50S, 50 N SRIS 9/94 ONTROLS Larger LWO/Pump controller units are installed on equalizing lines. The piping must be full size and include cross connections where pipes change direction. ach control should include its own blow down piping and valves. Recommended ual Valve low-own Piping These controls should be blown down daily when installed on commercial/industrial boilers and weekly in residential applications. Regular blow down keeps the control free of sediment and ensures it operates properly. When blowing down a control at pressure, the blow down valve should be opened slowly. The piping needs to be warmed up and stagnant water in the drain piping needs to be pushed out. Suddenly opening a blow down valve causes steam to condense, which creates water hammer. rushed floats and damaged linkages can occur when water hammer occurs due to improper blow down piping. onnecting lines to boiler should be straight runs Positive Shutoff Valve (all Valve) Slow Opening Valve "Throttling Valve" (Gate Valve) oiler ontrols or these reasons, recommends a dual valve blow-down system for each control. Proper low-down Procedure: (Using dual valve system). With water in the boiler at its normal level, open Positive Shut-off all Valve. 2. Open Throttling Gate Valve slowly until drain piping heats up and then open fully. Observe that the water level starts falling in the gauge glass.. lose Throttling Gate Valve after verifying that the pump contacts have closed and the burner contacts have opened thus shutting down the boiler. Note: If this does not happen, immediately close all valves, turn off burner and correct the problem. 4. lose Positive Shut-off all Valve. 5. Observe that the water level returns to its normal level before leaving site. Piping must be pitched to drain with no restrictions or reduction in pipe size 49

24 L ow Water ut-offs Mech a n i c a l ombination Low Water ut-off/pump ontro l l e rs for Steam oilers Series 9 Low Water ut-off/pump ontrollers or commercial and industrial low or high pressure steam boilers Maintains consistent water level regardless of pressure or boilers of any steaming capacity No. 5 Switch included Magnetic repulsion eliminates need for bellows Optional features Manual reset 7 switch (5ohm proportional control signal) to maintain constant boiler water level " connections Maximum pressure 50 psi (0.5 kg/cm 2 ) SRIS 9 lectrical Ratings 45 V at 20 or 240 V G H (256) (47) 5 9 (42) 4 5 (.5) (225) (27) O rdering Info r m a t i o n ombination low water cut-off/ 5.0 (5.9) pump controller w/no. 5 switch 9 - M w/manual reset 5.0 (5.9) w/no. 7 switch 5.5 (6.0) M W/manual reset 5.5 (6.0) 50

25 L ow Water ut-offs Mech a n i c a l ombination Low Water ut-off/pump ontro l l e rs for Steam oilers Series 9 Low Water ut-off/pump ontrollers or commercial and industrial low or high pressure steam boilers Maintains consistent water level regardless of pressure Water column with integral tappings for gauge glass and tri-cock installations or boilers of any steaming capacity No. 5 Switch included Magnetic repulsion eliminates need for bellows Optional features Manual reset 7 switch (5ohm proportional control signal) to maintain constant boiler water level " connections Maximum pressure 50 psi (0.5 kg/cm 2 ) lectrical Ratings 45 V at 20 or 240 V SRIS 9 O rdering Info r m a t i o n ombination low water cut-off/ pump controller w/no. 5 switch 52.5 (2.8) w/alternate tappings 52.5 (2.8) w/no. 7 switch 52.5 (2.8) M w/manual reset 52.5 (2.8) M w/manual reset 52.5 (2.8) w/alternate tappings 52.5 (2.8) M w/manual reset 52.5 (2.8) w/no. 7 switch 52.5 (2.8) w/alternate tappings 52.5 (2.8) w/no. 7 switch 52.5 (2.8) 9 - M w/manual reset 52.5 (2.8) w/no. 7 switch 52.5 (2.8) 9-7 M w/manual reset 52.5 (2.8) M w/manual reset 52.5 (2.8) 9 - G w/alternate tappings 52.5 (2.8) Model G H J K G 4 Model L M N P Q R (24) 0 6 (274) (0) (7) 9- (292) 0 6 (274) (0) 2 4 (57) (24) 0 6 (274) (0) (7) 9- (292) 0 6 (274) (0) 2 4 (57) 9-G (292) 0 6 (274) (0) 2 4 (57) Model S T U V W X (7.4) 7 (445) 20 (52) (89) (89) 6 (52) (7.4) 7 (445) 20 (52) (89) (89) 6 (52) (7.4) 7 (445) 20 (52) (89) (89) 6 (52) (7.4) 7 (445) 20 (52) (89) (89) 6 (52) 9-G 6 4 (7.4) 7 (445) 20 (52) (89) (89) 6 (52) 5

26 L ow Water ut-offs Mech a n i c a l ombination Low Water ut-off/pump ontro l l e rs for Steam oilers Series 94 Low Water ut-off/pump ontrollers or commercial and industrial low or high pressure steam boilers Maintains consistent water level regardless of pressure or boilers of any steaming capacity No. 5 Switch included Magnetic repulsion eliminates need for bellows Optional features Manual reset 7 switch (5ohm proportional control signal) to maintain constant boiler water level SPT threads 4" connections Maximum pressure 250 psi (7.6 kg/cm 2 ) Ten bolt flange SRIS 94 lectrical Ratings 45 V at 20 or 240 V O rdering Info r m a t i o n ombination low water cut-off/ 52.5 (2.8) pump controller w/no. 5 switch w/alternate tappings 50. (22.8) 94 - M w/manual reset 50. (22.8) M w/no. 7 switch 52.5 (2.8) 94 - M w/manual reset 52.5 (2.8) w/no. 7 switch 52.0 (2.6) Model 94 6 (52) 7 (78) (268) 8 6 (478) 94-6 (52) 7 (78) (268) 8 6 (478) Model G H (49) 4 6 (9) 8 4 (222) ( ) (49) 4 6 (9) 8 4 (222) ( ) Model J K L M N (5) 4 4 (5) (52) 4 (2)

27 L ow Water ut-offs Mech a n i c a l ombination Low Water ut-off/pump ontro l l e rs for Steam oilers Series 94 Low Water ut-off/pump ontrollers or commercial, and industrial low or high pressure steam boilers Maintains consistent water level regardless of pressure or boilers of any steaming capacity Water column with integral tappings for gauge glass and tri-cock installations No. 5 Switch included Magnetic repulsion eliminates need for bellows Optional features Manual reset 7 switch proportional 0-5 ohm control to maintain constant boiler water level 4" connections Maximum pressure 250 psi (7.6 kg/cm 2 ) Ten bolt flange lectrical Ratings 45 V at 20 or 240 V Model G H J K SRIS 94 O rdering Info r m a t i o n ombination low water cut-off/ 72.0 (2.7) pump controller w/series 5 switch w/alternate tappings 72.0 (2.7) w/series 7 switch 72.0 (2.7) 94 - M w/manual reset 72.0 (2.7) w/series 7 switch 72.0 (2.7) 94-7 M w/manual reset 72.0 (2.7) w/alternate tappings 72.0 ( Y 4 4 Model L M N P Q R S (295) 6 4 (7.4) 6 (2) 2 6 (7) 4 (2) 2 8 (60) (27) 6 4 (7.4) 6 (2) 2 6 (7) 4 (2) 2 8 (60) (27) 6 4 (7.4) 6 (2) 2 6 (7) 4 (2) 2 8 (60) Model T U V W X Y (48) 20 (52) (76) (76) 6 (52) 0 6 (274) (48) 20 (52) (76) (76) 6 (52) 0 6 (274) (48) 20 (52) (76) (76) 6 (52) 0 6 (274) 5

28 Water eeders lectric Series W Uni-Match lectric Water eeders or low pressure steam boilers with cold water feed Slide switch allows the timing cycle to be matched to that of the boiler size and operation lectronic operation provides consistent, accurate cycleto-cycle repeatability Universal design simplifies selection and reduces stock an be used with mechanical or electronic low water cut-off controls Manual feed button Includes 8 thread x " (mm) tubing adapters for quick installation with " (mm) copper tubing asy to clean strainer Maximum water pressure 50 psi (0.5 kg/cm 2 ) Maximum boiler pressure 5 psi ( kg/cm 2 ) Maximum water temperature 20 (49 ) Maximum ambient temperature 00 (8 ) Maximum power consumption (during water feed only) 5 V at 24 V 20 V at 20 V (50 or 60 Hz) U n i - M a t c h G H J K (7) 6 4 (59) (24) 4 4 (08) 8 7 (9) 6 (78) 8 (26) 5 6 (48) O rdering Info r m a t i o n W U lectric Water eeder, 24V 2.8 (.) W U lectric Water eeder, 20V 2.8 (.) 54

29 Water eeders lectric Series 0- lectric Water eeders or low pressure steam boilers with cold water feed liminates necessity to manually add water to the boiler an be used with mechanical or electronic low water cut-off controls Quick-change replaceable cartridge valve and strainer Manual feed button Model 0- features a 20 V solenoid Model features a 24 V solenoid and a separate 50V transformer Maximum water supply pressure 50 psi (0.5 kg/cm 2 ) Maximum boiler pressure 25 psi (.8 kg/cm 2 ) Maximum inlet water temperature 20 (49 ) Maximum power consumption 40 V at 24 V 40 V at 20 V Series 0- l ow ata Pressure ifferential psi (kg/cm 2 ) low Rate gpm (lpm) 5 (. 4 ). 4 ( 5. ) 0 (. 7 ). 7 ( 6. 4 ) 20 (. 4 ) 2. ( 7. 9 ) 40 ( 2. 8 ) 2. 9 (. 0 ) 60 ( 4. 2 ). 4 ( 2. 9 ) 80 ( 5. 6 ) 4. 0 ( 5. ) G H 4 6 (0) (75) 5 8 (0) (92) 5 6 (76) O rdering Info r m a t i o n lectric water feeder, 20V 2. 8 (. ) 0-24 V lectric water feeder, 24V 2. 8 (. ) 55

30 Water eeders Mech a n i c a l Series 47/47-2 M e chanical Water eeders / L ow Water ut-offs or steam and hot water boilers with cold water feed ontinuous maintenance of minimum safe water level, independent of electrical service Proportional feed action Quick hook-up fittings provided Quick-change replaceable cartridge valve and strainer Optional features No. 2 switch Manual reset Model 47 can be field upgraded with a No. 2 switch to add low water cut-off function Maximum water supply pressure 50 psi (0.5 kg/cm 2 ) Maximum inlet water temperature 20 (49 ) Maximum boiler pressure 25 psi (.8 kg/cm 2 ) Series 47 Series 47-2 lectrical Ratings Motor Switch Rating (mperes) Voltage ull Load Locked Rotor Pilot uty 20 V V at 20 or 240 V 240 V Hz G 7 8 (02) 5 4 () 7 8 (87) min (67) H J K L M N P (86) (7) 4 (56) max (0) (270) 29 (58.4) (5.7) (76) (5) 56

31 Water eeders Mech a n i c a l Series 47 (continued) Mechanical Water eeders a p a c i t i e s O rdering Info r m a t i o n Mechanical water feeder 27.5 (2.5) w/no. 2 switch 28.5 (.0) M w/manual reset 28.5 (.0) 47 - X w/o quick hook-up fittings 25.0 (.4) 47-2 X w/o quick hook-up fittings 26.0 (.8) 57

32 Water eeders Mech a n i c a l Series 247/247-2 Mechanical Water eeders/low Water ut-offs or steam and hot water boilers with cold water feed ontinuous maintenance of minimum safe water level, independent of electrical service Proportional feed action Quick-change replaceable cartridge valve and strainer Quiet, durable operation Isolated feed valve minimizes lime and scale build-up Optional features No. 2 switch Manual reset Model 247 can be field upgraded with a No. 2 switch to add low water cut-off function Maximum water supply pressure 50 psi (0.5 kg/cm 2 ) Maximum inlet water temperature 20 (49 ) Maximum vessel pressure 0 psi (2. kg/cm 2 ) Series 247 Series lectrical Ratings Motor Switch Rating (mperes) Voltage ull Load Locked Rotor Pilot uty 20 V V at 20 or 240 V 240 V Hz G H J K 6 (65) 9 8 (22) 5 8 (0) (7) (67) (86) (5.7) 29 (48.4) 58

33 Water eeders Mech a n i c a l Series 247 (continued) Mechanical Water eeders a p a c i t i e s O rdering Info r m a t i o n Mechanical water feeder 22.0 (0.0) w/no. 2 switch 22.5 (0.2) M w/manual reset 22.5 (0.2) 59

34 Water eeders Mech a n i c a l Series 5/5-2 Mechanical Water eeders/low Water ut-offs or low pressure steam and hot water boilers larger than 5,000 sq. ft. (465m 2 ) capacity with cold water feed Quick-change replaceable cartridge valve and strainer Optional features No. 2 switch Manual reset loat block Proportional feed action Model 5 can be field upgraded with a No. 2 switch to add low water cut-off function Maximum water supply pressure 50 psi (0.5 kg/cm 2 ) Maximum inlet water temperature 20 (49 ) Maximum vessel pressure 5 psi (2.5 kg/cm 2 ) Series 5 lectrical Ratings Motor Switch Rating (mperes) Voltage ull Load Locked Rotor Pilot uty 20 V V at 20 or 240 V 240 V Hz 8 (20) 0 8 ( ) 5 4 (46) 4 Series 5-2 a p a c i t i e s O rdering Info r m a t i o n Mechanical water feeder 5. (6.0) w/float block 8.5 (7.5) w/series 2 switch 8. (7.4) M w/manual reset 8. (7.4) w/series 2 switch 5.8 (6.2) M w/manual reset 5.7 (6.2) 60

35 Water eeders Mech a n i c a l Series 5-S/5-S-2 Mechanical Water eeders/low Water ut-offs or high capacity [up to 5,000 sq. ft. (250m 2 )] low pressure steam and hot water boilers with cold water feed Optional features No. 2 switch Manual reset loat block Proportional feed action Maximum water supply pressure 00 psi (7 kg/cm 2 ) Maximum inlet water temperature 20 (49 ) Maximum vessel pressure 5 psi (2.5 kg/cm 2 ) Series 5-S lectrical Ratings Motor Switch Rating (mperes) Voltage ull Load Locked Rotor Pilot uty 20 V V at 20 or 240 V 240 V Hz 8 8 (20) 0 8 ( ) 5 4 (46) Series 5-S-2 4 a p a c i t i e s O rdering Info r m a t i o n 5-S 5600 Mechanical water feeder 6.5 (6.6) 5-S S w/no. 2 switch 7. (6.9) 5-S-2-M S-2 w/manual reset 7. (6.9) 5-S S w/float block 4.8 (9.0) 5-S S w/no. 2 switch 4.8 (9.0) 5-S-2-M S-2 w/manual reset 4.7 (9.8) 6

36 Water eeders Mechanical Series 5/5-2 Mechanical Water eeders/low Water ut-offs or low pressure steam and hot water boilers larger than 5,000 sq. ft. (465m 2 ) with hot or cold water feed Optional features No. 2 switch Manual reset loat block LOSING LVL oiler ontrols Proportional feed action Model 5 can be field upgraded with a No. 2 switch to add low water cut-off function Maximum water supply pressure 50 psi (0.5 kg/cm 2 ) Maximum inlet water temperature 20 (49 ) Maximum vessel pressure 75 psi (5. kg/cm 2 ) Series 5 lectrical Ratings Motor Switch Rating (mperes) Voltage ull Load Locked Rotor Pilot uty 20 V V at 20 or 240 V 240 V Hz LOSING LVL Series (206) 0 8 (264) 5 4 (46) 4 apacities Number Number escription lbs. (kg) Mechanical water feeder 8.0 (7.2) w/float block 42.0 (9.0) w/no. 2 switch 42.0 (9.0) 5--2-M w/no. 2 switch & manual reset 42.0 (9.0) w/no. 2 switch 8.5 (7.5) 5-2-M w/manual reset 8.5 (7.5) R ISHRG gpm (kg/hr.) lbs./hr. 20 (456) 0, (4082) (629) (75) (2722) (2268) (84) (6) (907) (454) 9,000 8,000 7,000 6,000 5,000 4,000,000 2,000,000 Maximum apacity apacity at Switch ut-off IRNTIL PRSSUR IN POUNS PR SQ. IN. (Water pressure less boiler pressure) STM Sq.t. 40,000 6,000 2,000 28,000 24,000 20,000 6,000 2,000 8,000 4,000 (0) 0 0 psi (kg/cm 2 ) (0) (.7) (.4) (2.) (2.8) (.5) (4.2) (4.9) (5.6) (6.) (7.0) OILR hp (Kilowatts) 290 (284) 26 (2559) 22 (2274) 20 (990) 74 (706) 45 (42) 6 (7) 87 (85) 58 (569) 29 (284) 0 62

37 Make-Up Water eeders In boiler feed systems with higher pressures, a make-up feeder is usually provided on the condensate receiver. It adds water to the receiver when necessary so there is always an adequate supply for boiler demand. ITT Make-up feeders provide large feeding capacity. Unless otherwise stated, valves and seats are of stainless steel and protected by a large integral strainer. Positive alignment of the valve is assured by cam & roller, straight thrust action. These feeders can be used for many other liquid control applications such as: Pharmaceutical Laboratory Industrial istillation equipment Receiver tanks vaporative coolers Humidifiers quariums Steam baths Wet and dry hygrometers oiler ontrols Water eeding apacity lbs./hr. (kg/hr.) Model ity Water Supply Pressure with /4" Pipe and No Tank Pressure, 0 psi (kg/cm 2 ) Number 0 (.7) 20 (.4) 0 (2.) 40 (2.8) 50 (.5) 60 (4.) 70 (4.8) 80 (5.5) 90 (6.2) (406) 4500 (204) 5600 (2540) 6550 (297) 7400 (57) 850 (697) 8800 (992) 9400 (4264) 0200 (4627) 2 & (860) 6000 (2722) 7500 (402) 8600 (90) 9600 (455) 0500 (476) 00 (526) 2000 (544) 200 (5988) (454) 500 (680) 800 (86) 200 (95) 2400 (089) 2600 (79) 2800 (270) 000 (6) 00 (497) (907) 000 (6) 700 (678) 400 (850) 4800 (277) 85-S 000 (6) 4000 (84) 5000 (2268) 6200 (282) 55-S 2500 (4) 600 (6) 4500 (204) 5200 (259) 5800 (26) 6500 (2948) 7000 (75) 7600 (447) 8800 (992) 6

38 Water eeders Make-Up Series 25- Make-Up Water eeder or boiler receiver tanks loat operated Proportional feed action oiler ontrols Soft seat provides positive seal Seal between float chamber and valve chamber is not a positive seal Maximum water supply pressure 00 psi (7 kg/cm 2 ) Maximum inlet water temperature 20 (49 ) Maximum vessel pressure 5 psi (2.5 kg/cm 2 ) Series 25- G H J G H J 6 (2) () 8 8 (206) (2.7) 0 8 (264) Make-up water feeder 7.5 (7) w/float block 4.8 (9) apacities R ISHRG (kg/hr.) lbs./hr. (4990),000 gpm (lpm) OILR hp (Kilowatts) 22 (8.27) 9 (27) (456) 0, (75.70) 290 (284) (4082) 9,000 8 (68.) 26 (2559) (629) (75) (2722) 8,000 7,000 6,000 Maximum apacity 6 (60.56) 4 (52.99) 2 (45.42) 22 (2274) 20 (990) 74 (706) (2268) 5,000 0 (7.85) 45 (42) (84) 4,000 8 (0.28) 6 (7) (6),000 6 (22.7) 87 (85) (907) 2,000 4 (5.4) 58 (569) (454),000 2 (7.57) 29 (284) (0) 0 0 psi (kg/cm 2 ) (0) (.7) (.4) (2.) (2.8) (.5) (4.2) (4.9) (5.6) (6.) (7.0) (0) 0 (0) WTR SUPPLY PRSSUR IN LS. PR SQ. IN. 64

39 Water eeders Make-Up Series 2 Make-Up Water eeder or boiler receiver tanks irect mounting eliminates need for equalizing connections Proportional feed action Mounting lange six 7 6" (.mm) bolt holes on a 5 4" (46mm) bolt circle Soft seat provides positive seal Maximum water supply pressure 50 psi (0.5 kg/cm 2 ) Maximum inlet water temperature 20 (49 ) Maximum vessel pressure 5 psi (2.5 kg/cm 2 ) Series 2 G H 8 (26) 5 6 (84) (4) 8 6 (224) 4 4 (2) 6 4 (59) (86) H G oiler ontrols Series 22 Make-Up Water eeder or boiler receiver tanks irect mounting eliminates need for equalizing connections Proportional feed action Mounting lange six 7 " (.5mm) bolt holes on a 8 " (26mm) bolt circle Soft seat provides positive seal Maximum water supply pressure 50 psi (0.5 kg/cm 2 ) Maximum inlet water temperature 20 (49 ) Maximum vessel pressure 5 psi (2.5 kg/cm 2 ) apacities (kg/hr.) lbs./hr. PITY URV 6, , ,000 28, ,000 24, , , , , , , ,000 8, ,000 4, psi (kg/cm 2 ) (0) (0.7)(.4)(2.) (2.8)(.5)(4.2)(4.9) (5.6)(6.)(7.0)(7.7) (8.4)(9.)(9.8)(0.5) (7258) (6804) (650) (5897) (544) (4990) (456) (4082) (629) (75) (2722) (2268) (84) (6) (907) (454) (0) WTR SUPPLY PRSSUR IN LS. PR SQ. IN. gpm (lpm) OILR (2.2) (.55) (05.98) (98.4) (90.84) (8.27) (75.70) (68.) (60.56) (52.99) (45.42) (7.85) (0.28) (22.7) (5.4) (7.57) (0) hp (Kilowatts) 464 (4549) 45 (4264) 406 (980) 77 (696) 48 (4) 9 (27) 290 (284) 26 (2559) 22 (2274) 20 (990) 74 (706) 45 (42) 6 (7) 87 (85) 58 (569) 29 (284) 0 (0) Series 22 G H 8 (26) 4 6 (84) (4) 8 6 (224) 4 4 (2) 6 4 (59) 4 (20) 9 (24) Make-up water feeder 5. (6.9) Make-up water feeder 2. (9.7) H G 65

40 Water eeders Make-Up Series 847 Make-Up Water eeder or receiver tanks in commercial or industrial applications Mounts directly on the receiver, eliminating need for equalizing connections Quick-change replaceable cartridge valve and strainer WTR LIN oiler ontrols Proportional feed action Mounting lange six 7 6" (.mm) bolt holes on a 5 4" (46mm) bolt circle Optional features No. 2 switch lternate valve orientation Maximum supply pressure 50 psi (0.5 kg/cm 2 ) Series 847 Maximum inlet water temperature 20 (49 ) Maximum receiver pressure 25 psi (.8 kg/cm 2 ) (86) (25) (7) 9 6 (90) 7 6 (87) Make-up water feeder (5.0) w/alternate valve orientation 2 (5.4) w/no. 2 switch 2 (5.4) apacities gpm (kg/hr.) lbs./hr. STM Sq. t. OILR tu/hr. (K-alories/Hr.) OILR hp (Kilowatts) 8 (84) 4,000 6,000 4,000,000 (5,800) 6 (7) (6) (907) (454),000 2,000,000 Maximum apacity apacity at Switch ut-off 2,000 8,000 4,000,000,000 (,900) 2,000,000 (7,900),000,000 (4,000) 87 (85) 58 (569) 29 (284) 0 (0) 0 psi (kg/cm 2 ) (0) (.7) (.4) (2.) (2.8) (.5) (4.2) (4.9) (5.6) (6.) (7.0) IRNTIL PRSSUR IN POUNS PR SQ. IN. (Water pressure less boiler pressure) 66

41 Water eeders Make-Up Series 85 Make-Up Water eeder or receiver tanks in commercial or industrial applications Mounts directly on the receiver, eliminating need for equalizing connections Quick-change replaceable cartridge valve and strainer Proportional feed action Mounting lange six 7 6" (.mm) bolt holes on a 5 4" (46mm) bolt circle Maximum water supply pressure 50 psi (0.5 kg/cm 2 ) Maximum inlet water temperature 20 (49 ) Maximum receiver pressure 5 psi (2.5 kg/cm 2 ) Model 85-S Make-Up Water eeder xtended float and rod assembly Wider operating range Maximum water supply pressure 00 psi (7 kg/cm 2 ) Maximum inlet water temperature 20 (49 ) Maximum receiver pressure 5 psi (2.5 kg/cm 2 ) Make-up water feeder 4 (6.4) 85-S w/extended float & rod assy. 6 (7.) Series 85 Model 85-S WTR LIN 4 (298) (25) (7) 9 6 (90) (87) WTR LIN 2 4 (24) (25) 6 (8) 9 6 (90) (87) oiler ontrols apacities Model 85 apacities Model 85-S R ISHRG gpm (kg/hr.) lbs./hr. 20 (456) 0, (4082) (629) (75) (2722) (2268) (84) (6) (907) (454) 9,000 8,000 7,000 6,000 5,000 4,000,000 2,000,000 Maximum apacity apacity at Switch ut-off IRNTIL PRSSUR IN POUNS PR SQ. IN. (Water pressure less boiler pressure) STM Sq.t. 40,000 6,000 2,000 28,000 24,000 20,000 6,000 2,000 8,000 4,000 (0) 0 0 psi (kg/cm 2 ) (0) (.7) (.4) (2.) (2.8) (.5) (4.2) (4.9) (5.6) (6.) (7.0) OILR hp (Kilowatts) 290 (284) 26 (2559) 22 (2274) 20 (990) 74 (706) 45 (42) 6 (7) 87 (85) 58 (569) 29 (284) 0 R ISHRG gpm (kg/hr.) lbs./hr. 20 (456) 0, (4082) (629) (75) (2722) (2268) (84) (6) (907) (454) 9,000 8,000 7,000 6,000 5,000 4,000,000 2,000,000 Maximum apacity apacity at Switch ut-off IRNTIL PRSSUR IN POUNS PR SQ. IN. (Water pressure less boiler pressure) STM Sq.t. 40,000 6,000 2,000 28,000 24,000 20,000 6,000 2,000 8,000 4,000 (0) 0 0 psi (kg/cm 2 ) (0) (.7) (.4) (2.) (2.8) (.5) (4.2) (4.9) (5.6) (6.) (7.0) OILR hp (Kilowatts) 290 (284) 26 (2559) 22 (2274) 20 (990) 74 (706) 45 (42) 6 (7) 87 (85) 58 (569) 29 (284) 0 67

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions

More information

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions. B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary

More information

Considering the alternatives to the McDonnell & Miller Series 150 mercury LWCO?

Considering the alternatives to the McDonnell & Miller Series 150 mercury LWCO? Considering the alternatives to the McDonnell & Miller Series 150 mercury LWCO? Series 150E Series 150S Which one is best for me? 1 150S or 150E? WHICH IS THE BETTER ALTERNATIVE TO MERCURY? The McDonnell

More information

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual QUALITY STEAM SPECIALTIES SINCE ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual Section: C500 Bulletin: C500.40 Date: 06-26-01 Supersedes: New PRODUCT DESCRIPTION: The Clark-Reliance

More information

! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions. McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes

More information

Electrical Circuits... 2. Types of Electrical Switches... 3. Switch Operation... 4. Standard Combinations... 6

Electrical Circuits... 2. Types of Electrical Switches... 3. Switch Operation... 4. Standard Combinations... 6 TEIAL AD GEERAL IFORMATIO BASI WIRIG LIK O DESIRED PAGE Electrical ircuits........................................................................... 2 Types of Electrical Switches..................................................................

More information

Float and Thermostatic Traps Series H, C and X

Float and Thermostatic Traps Series H, C and X Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT

More information

Features and Benefits

Features and Benefits SPC 1000 Single Point Control ABC-1000 Retropak Section: F100 Bulletin: 100.2 Date: 03/09 Supercedes: 5/01 Features and Benefits Design pressure to 450 WSP Meets ASME, CSD-1 Requirements LED Monitoring

More information

Automatic Control Valves WATTS EU 100 Series

Automatic Control Valves WATTS EU 100 Series utomatic ontrol Valves WTTS U Series The Watts Industries range of automatic control valves consist of a hydraulically operated valve, which is controlled by a pilot circuit. The main valve (U ) is the

More information

BASIC WIRING Electrical Circuits...141. Types of Electrical Switches...142. Switch Operation...143. Standard Combinations...144

BASIC WIRING Electrical Circuits...141. Types of Electrical Switches...142. Switch Operation...143. Standard Combinations...144 TEIAL AD GEERAL IFORMATIO ontents BASI WIRIG Electrical ircuits...........................................................................141 Types of Electrical Switches..................................................................142

More information

Factory owners must ensure the boiler is:

Factory owners must ensure the boiler is: Factory owners must ensure the boiler is: * Registered with the Boilers and Pressure Vessels Division, Labour Department * Examined by an appointed examiner and has a valid certificate of fitness * Supervised

More information

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE Hot Water Boilers and Controls Why Condensing Boilers are Different Presented Oct. 14, 2008 Long Island Chapter, ASHRAE H.W. Boilers and Controls Major types of boilers Advantages and disadvantages Resistance

More information

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI). SECTION 23 52 30 PART 1 - GENERAL 1.01 RELATED WORK A. Section 23 05 00: Common Work Results for HVAC B. Section 23 25 00: Chemical Water Treatment C. Section 23 51 23: Flue Piping 1.02 QUALITY ASSURANCE

More information

FLASH TANK ECONOMIZER PRODUCT GUIDE

FLASH TANK ECONOMIZER PRODUCT GUIDE FLASH TANK ECONOMIZER PRODUCT GUIDE Overview A flash tank is used to recover blowdown energy in the form of flash steam and blowdown. This can only be used with a deaerator or some other pressurized device.

More information

REGULATORS 175/153 Series

REGULATORS 175/153 Series 175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed

More information

Series IDU/IDF. Refrigerated Air Dryer

Series IDU/IDF. Refrigerated Air Dryer Refrigerated ir ryer Series IU/IF The models IF1 to 11 and IU3 to 6 have been revised. For details, refer to catalog no. S30-8. Similar updating for other IF/IU models is scheduled to follow shortly. In

More information

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00 RESIDENTIAL HEATING OIL SERVICE CONTRACT This service contract covers all routine service and maintenance of your residential oil fired furnace or boiler. In addition this contract covers all service calls

More information

BERMAD Fire Protection

BERMAD Fire Protection 400E-2M/700E-2M IOM Bermad Electrically Controlled Deluge Valve with EasyLock Manual Reset Model: 400E-2M/700E-2M INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 400E-2M/700E-2M Bermad

More information

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage

More information

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

TANKLESS WATER HEATER INSTALLATION DIAGRAMS TANKLESS WATER HEATER INSTALLATION DIAGRAMS Installation Diagrams Tankless Installation / Optional Return Small 10-15 Gallon Point-of-Use Water Single and Optional Return : One single, small capacity water

More information

Some Criteria for Choosing a Steam Boiler for a Microbrewery

Some Criteria for Choosing a Steam Boiler for a Microbrewery Some Criteria for Choosing a Steam Boiler for a Microbrewery Jack Coe Rite Engineering and Manufacturing Corporation Breweries rely on steam heating for a number of functions, primarily to heat the brew

More information

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE 2008-36 TSG-PRESTIGE Date revised: 12/6/10

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE 2008-36 TSG-PRESTIGE Date revised: 12/6/10 prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE Date revised: 12/6/10 2008-36 TSG-PRESTIGE Table of Contents INTRODUCTION Page 1-2 SERVICING TIPS AND INSTRUCTIONS Page 3-4

More information

Preventing Overheated Boiler Incidents

Preventing Overheated Boiler Incidents Preventing Overheated Boiler Incidents PSE&G Appliance Service October 2012 Runaway Boiler Explosion Review Items Hazard Background Past Incidents PSE&G Emergency Response Future Process Improvements What

More information

Fossil fuel heating equipment

Fossil fuel heating equipment Fossil fuel heating equipment principles and troubleshooting techniques Application Note This application note was written to provide you with an understanding of the basic principles of fossil fuel heating

More information

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing) CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.

More information

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose: PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,

More information

MM-825(A) McDonnell & Miller General Catalog

MM-825(A) McDonnell & Miller General Catalog MM-825(A) General Catalog ITT the industry leader. Delivering reliable performance and safety in boiler and level control products for over 80 years. Whether it s ease of serviceability, continuous improvement,

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE. SIT Group 820 NOVA mv MULTIFUNCTIONAL CONTROL FOR GAS THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE PIN 3AP700/2 SINGLE-KNOB MULTIFUNCTIONAL

More information

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger

More information

Fire Pump Plan Review March 2010

Fire Pump Plan Review March 2010 Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:

More information

Blowdown vessels Meeting the requirements of HSE PM60

Blowdown vessels Meeting the requirements of HSE PM60 Blowdown vessels Meeting the requirements of HSE PM60 BDV60 blowdown vessels complete range of equipment for the safe disposal of boiler blowdown Boiler blowdown Steam boilers must be blown down to remove

More information

SIOUX HYBRID WATER HEATER

SIOUX HYBRID WATER HEATER SIOUX Hybrid Water Heater for the Concrete Industry SIOUX HYBRID WATER HEATER Patent Pending Maximizing the Benefits of Coil and Direct-Fired Heating Technologies Higher Discharge Temperature True High-Efficiency

More information

Steam System Efficiency. Bill Lumsden Leidos Engineering

Steam System Efficiency. Bill Lumsden Leidos Engineering Steam System Efficiency Bill Lumsden Leidos Engineering Steam System Efficiency Steam System Efficiency Key Take-aways: Review of the properties of ice, water, and steam Learn the basics of steam trap

More information

TYPE E Main Valve Sizes 3 /8 through 12

TYPE E Main Valve Sizes 3 /8 through 12 SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,

More information

Boiler Preparation, Start-Up and Shutdown

Boiler Preparation, Start-Up and Shutdown Boiler Preparation, Start-Up and Shutdown Learning Outcome When you complete this module you will be able to: Describe the basic preparation of a boiler for start-up, and the start-up and shutdown procedures.

More information

Model 43AP Pneumatic Controller, Style B

Model 43AP Pneumatic Controller, Style B Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set

More information

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

ELECTRIC/DIESEL FIRE PUMP CHECK LIST BUILDING NAME: DESIGNER: SCO REPRESENTATIVE: PUMP MANUF.: LOCATION: INSTALLER: DATE: OWNER NAME: INSTALLATION Certificate for flushing and hydrostatic test furnished Piping been hydrostatically tested

More information

Electronic Flow Switches

Electronic Flow Switches Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

Commercial Gas Water Heaters

Commercial Gas Water Heaters POWERED BURNER MODELS LARGE-VOLUME POWERED BURNER FEATURES The large-volume powered burner line includes the largest, most powerful A. O. Smith tanktype gas water heaters. With tank capacities up to 600

More information

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

3, 4, 6 & 8 Model H Series Alarm Check Valve Installation and Maintenance Guide ", ", " & " Model H Series Alarm Check Valve Installation and Maintenance Guide 077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE 99-- 00-2-0 FAX 99--92 www.globesprinkler.com OCTOBER 2 C- BULLETIN A.C.V.I.M.,

More information

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business

More information

REGULATORS D& HD Series

REGULATORS D& HD Series Watson McDaniel reserves the right to change the designs and/or materials of its products out notice. 2002 Watson McDaniel Company Ductile Iron body - HD Series Full port strainer & blowdown valve on pilot

More information

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The

More information

HYDROSTATIC TEST PUMPS

HYDROSTATIC TEST PUMPS HYDROSTATIC TEST PUMPS MANUAL HYDROSTATIC TEST PUMPS Ideal for testing residential water lines. Also for pressure testing small pressure tanks, sprinkler, boiler and solar systems. Lightweight and easy

More information

PBX Series Quick Fit Connector Bimetallic Steam Traps

PBX Series Quick Fit Connector Bimetallic Steam Traps 6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge

More information

OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SE

OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SE OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SE HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203) 378-2659 FAX: (203)

More information

Medical Air Systems: Scroll

Medical Air Systems: Scroll GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing

More information

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. Tankless Electric (RTE) Troubleshooting

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. Tankless Electric (RTE) Troubleshooting Sequence of Operations 1 Power supply and field wiring block 2 Energy Cut Off (ECO) 3 Water flow plunger and cold inlet 4 Magnetic flow switch 5 Water temperature thermistor 6 Control panel and circuit

More information

Morrison Bros. Co. General Product Specifications

Morrison Bros. Co. General Product Specifications Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage

More information

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER Installation and service must be performed by a qualified service installer, service agency or the gas supplier. Oil Gas/Oil

More information

PLP - TERMS AND CONDITIONS

PLP - TERMS AND CONDITIONS PLP - TERMS AND CONDITIONS 2014-2015 Philadelphia Gas Works Residential Parts & Labor Plan Contract This Residential Parts & Labor Plan Contract (this Plan ) is available to customers of the Philadelphia

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

How To Clean Up A Reactor Water Cleanup

How To Clean Up A Reactor Water Cleanup General Electric Systems Technology Manual Chapter 2.8 Reactor Water Cleanup System TABLE OF CONTENTS 2.8 REACTOR CLEANUP SYSTEM... 1 2.8.1 Introduction... 2 2.8.2 System Description... 2 2.8.3 Component

More information

FAIRBANKS NIJHUIS FIRE PUMPS. www.fairbanksnijhuis.com

FAIRBANKS NIJHUIS FIRE PUMPS. www.fairbanksnijhuis.com FAIRBANKS NIJHUIS FIRE PUMPS www.fairbanksnijhuis.com FAIRBANKS NIJHUIS Long established as a leading fire pump manufacturer, Fairbanks Nijhuis offers a broad range of horizontal and vertical split case,

More information

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Installation, Operating and Maintenance Instructions 90/4.5.5 Rev. 0 Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Table of Contents SECTION I... 2 INSTALLATION...

More information

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual Manual No. 5EP-OM1-1 Electric Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION... 2 SEQUENCE

More information

High efficiency, cast-iron gas boiler

High efficiency, cast-iron gas boiler SENTRY High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler A smarter choice for informed The boiler you choose for your home

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) WARNING - HIGH VOLTAGE AC electrical circuits are connected to this heater. Do not attempt any service work on the

More information

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing 408-409

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing 408-409 Engineering Data Table of Contents Page No. I II Formulas, Conversions & Guidelines Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Sizing 408-409 Steam

More information

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS SECTION 1001 GENERAL 1001.1 Scope. This chapter shall govern the installation, alteration and repair of boilers, water heaters and pressure vessels.

More information

HS-901(A) BASIC STEAM HEATING SYSTEMS

HS-901(A) BASIC STEAM HEATING SYSTEMS HS-901(A) BASIC HEATING SYSTEMS One-Pipe Two-Pipe Basic Steam Heating Systems One-pipe steam heating system EQUALIZER SAFETY FACTOR STATIC HEAD PRESSURE DROP 2" HEATING UNIT 15" DRIP CONNECTION In a one-pipe,

More information

Commercial Semi-Instantaneous Water Heaters

Commercial Semi-Instantaneous Water Heaters FEATURES HWI Models A. O. Smith s HWI models are available for operation with steam or boiler water as the energy source. They are factory assembled with components sized, piped and checked at the factory

More information

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

CARING FOR YOUR WATER HEATER

CARING FOR YOUR WATER HEATER http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected

More information

TS93 EMR T/PT/TDE. Surface applied door closer

TS93 EMR T/PT/TDE. Surface applied door closer TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double

More information

Automation & Sanitization REPLACEMENT PARTS

Automation & Sanitization REPLACEMENT PARTS & Sanitization PROLOGIC GLX-PCB-PRO Main PCB, ProLogic GLX-PL-LOC-P-4 Display, Local, ProLogic, P-4 GLX-PL-LOC-PS4 Display, Local, ProLogic, PS-4 GLX-PL-LOC-PS8 Display, Local, ProLogic, PS-8 GLX-PL-LOC-PS16

More information

Electro-Pneumatic Bus Door Control Mechanism

Electro-Pneumatic Bus Door Control Mechanism Electro-Pneumatic Bus Door Control Mechanism Application and Feature 1. Pneumatic Door Mechanism actuates the open/close movements of bus door through two double acting cylinders and two linkages with

More information

TECHNICAL DATA. Dry 122a. November 12, 2013

TECHNICAL DATA. Dry 122a. November 12, 2013 Dry 122a 1. PRODUCT DESCRIPTION The Viking is a quick-opening device. When installed with the required external Anti-flood Device, the assembly is designed to increase the operating speed of Viking Model

More information

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, 1060. Instruction No.

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, 1060. Instruction No. Instruction No. AERCO INTERNATIONAL, Inc., Northvale, New Jersey, 07647 USA PIPING GUIDE GF-115-P Modulex Gas Fired Boiler Systems Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909,

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY 82-13-1 O-Ring (Rear) The Lead Screw Assembly is shipped separately. Note: Install Electrical and Pneumatic Circuitry. Be Sure electrical and pneumatic

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

Model 5600SE Downflow

Model 5600SE Downflow Service Manual IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specification Sheet...................................................................................

More information

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES SECTION 15062 STEAM AND CONDENSATE PIPING PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. Comply with the provisions of the following: 1.2 DESIGN CRITERIA 1. ASME B 31.9 Building Services Piping : for

More information

Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information

Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information Steam Humidifier Model 800 Residential Steam Humidifier Owner s Manual Includes Safety & Operating Instructions and Warranty Information READ AND SAVE THESE INSTRUCTIONS TABLE OF CONTENTS Safety Cautions...

More information

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459 SECTION 15459 PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work

More information

Expert Report. History of the development of water level control in steam- and hot water boilers

Expert Report. History of the development of water level control in steam- and hot water boilers Expert Report Dipl.-Ing. Jochen Loos Dipl.-Wirtschaftsing. (FH), Dipl.-Informationswirt (FH) Markus Tuffner, Bosch Industriekessel GmbH History of the development of water level control in steam- and hot

More information

Commercial Gas Furnace Upflow

Commercial Gas Furnace Upflow Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted

More information

DC400 Dispensing Cutoff System

DC400 Dispensing Cutoff System DC400 Dispensing Cutoff System DC404 and DC406 Installation Instructions Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838 6433 www.franklinfueling.com

More information

ASME Packaged Indirect Fired Water Heater

ASME Packaged Indirect Fired Water Heater Utilizes Or HTHW To Heat Domestic Water, Semi-Instantaneous or Storage Type Model BW Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining

More information

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide Water Circulation Pumps & Circulators Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide Taco Catalog # 100-41 Supersedes: 08/07/15 Effective Date: 09/01/15 Printed in

More information

G234X-55 Conventional Gas Boiler

G234X-55 Conventional Gas Boiler Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus G234X-55 fl oor standing hot water boiler(s), suitable with natural

More information

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps (20-100 GPM) 10 to 34 KW Stainless Steel Heaters

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps (20-100 GPM) 10 to 34 KW Stainless Steel Heaters Temperature Control Units Water & Oil - 00 F Portable Chillers Air & Water-Cooled 0-70 F Central Chillers Air & Water-Cooled Packages & Modules 0-70 F Pump Tank Stations Chilled or Tower Water 00-00 gallons

More information

Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4

More information

MONO BLOCK DIRECTIONAL CONTROL VALVE TS

MONO BLOCK DIRECTIONAL CONTROL VALVE TS SHIPPING: 2332 S 25TH STREET (ZIP 6815) MAILING: P.O. BOX #669 OMAHA, NE 6816 PHONE: (42) 344-4434 FAX: (42) 341-5419 HTTP://WWW.BRAND-HYD.COM MONO BLOCK DIRECTIONAL CONTROL VALVE TS TS312TSDTSTKJB TS2

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS SERVICE MANUAL Troubleshooting Guide and Instructions for Service (To be performed ONLY by qualified service providers) Models Covered

More information

VOYAGER 570G. 744A Sprayer Control

VOYAGER 570G. 744A Sprayer Control VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER

More information

MODEL 9000. Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.

MODEL 9000. Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference. MODEL 9000 Service Manual IMPORTANT: Fill in pertinent information on page for future reference. Job Specification Sheet * JOB NO. * MODEL NO. * WATER TEST * CAPACITY PER UNIT MAX. PER REGENERATION * MINERAL

More information

FRL/AirCare Air Controls & Accessories

FRL/AirCare Air Controls & Accessories FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor

More information

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance Bench Autoclave Standard Operating Procedure For Installation, Use and Maintenance 1. Introduction This SOP is intended for use with the following model, in a laboratory context: Type: Nuve Bench Top Steam

More information