knk5 wmoep5 vtmpq NUNAVUT WATER BOARD NUNAVUT IMALIRIYIN
|
|
- Cordelia Norman
- 8 years ago
- Views:
Transcription
1 P.O. BOX 119 GJOA HAVEN, NU X0E 1J0 TEL: (867) FAX: (867) KATIMAYINGI knk5 wmoep5 vtmpq NUNAVUT WATER BOARD NUNAVUT IMALIRIYIN Application for: (check one) WATER LICENCE APPLICATION FORM _x_ New Amendment Renewal Assignment LICENCE NO: (for NWB use only) 1. NAME AND MAILING ADDRESS OF APPLICANT/LICENSEE Mosher Engineering Limited, 1869 Upper Water Street, Suite AH202 Halifax, NS B3J1S9 Phone:_ Fax: _ ADDRESS OF CORPORATE OFFICE IN CANADA (if applicable) Phone: Fax: 3. LOCATION OF UNDERTAKING (describe and attach a topographical map, indicating the main components of the Undertaking) See attached appendix A Latitude: N Longitude: W NTS Map No. Scale 4. DESCRIPTION OF UNDERTAKING (attach plans and drawings) Project summary: Upgrades & Expansion to the existing Fuel Storage Facility including two new 3064 cu.m Jet A-1 Vertical Tanks, two new 2565 cu.m. LSDL Vertical Tank, one new 1956 cu.m. LSDL vertical Tank, relocation of three 1351 cu.m LSDL Vertical Tanks including all appurtenances; re-supply pipeline, connection and spill basin; operator s shelter; LSDL/Gasoline Dispenser Building; Jet A-1 Dispenser Building; Fencing and Granular base and berms. Hydrostatic test procedure. Salt water will be used to hydrostatically test the tanks shown on drawing C3 in Appendix B. All tanks will be cleaned and gas freed prior to test. The salt water will be pump from the beach of Rankin Inlet using a 4 nominal size portable pump to the pipeline. The pipeline runs from the beach uphill to the tankfarm and is connected to all the tanks. The water will be disposed by pouring the water in a 45 gal drum cut in half, full of holes and hydrophobic pads. This will act as a filter for the water. The exiting Page 1 of 9
2 tanks will be tested in August and September 2009 and the new tanks will be tested in the summer of Approximately 5000cum will be used per year. 5. TYPE OF UNDERTAKING (A supplementary questionnaire must be submitted with the application for undertakings listed in bold ) _x Industrial Mine Development Advanced Exploration Exploratory Drilling Remote/Tourism Camps Municipal Power Other (describe): 6. WATER USE To obtain water To modify the bed or bank of a watercourse To alter the flow of, or store, water To cross a watercourse To divert a watercourse Flood control _x Other (describe): Hydrostatic test of fuel storage tanks. 7. QUANTITY OF WATER INVOLVED (litres per second, litres per day or cubic metres per year, including both quantity to be used and quality to be returned to source) 5000 cum/year for 2009 and WASTE (for each type of waste describe: composition, quantity, methods of treatment and disposal, etc.) Sewage Solid Waste Hazardous Bulky Items/Scrap Metal Waste oil Greywater Sludges _x_ Other (describe):hydrophobic Pads. 9. PERSONS OR PROPERTIES AFFECTED BY THIS UNDERTAKING (give name, mailing address and location; attach if necessary) Not Applicable Land Use Permit DIAND Yes No If no, date expected Regional Inuit Association Yes No If no, date expected Page 2 of 9
3 Commissioner Yes No If no, date expected 10. PREDICTED ENVIRONMENTAL IMPACTS OF UNDERTAKING AND PROPOSED MITIGATION MEASURES (direct, indirect, cumulative impacts, etc.) Not Applicable NIRB Screening Yes No If no, date expected 11. INUIT WATER RIGHTS Will the project or activity substantially affect the quality, quantity, or flow of water flowing through Inuit Owned Lands and the rights of Inuit under Article 20 of the Nunavut Land Claims Agreement? No. 11. (Continued) If yes, has the applicant entered into an agreement with the Designated Inuit organization to pay compensation for any loss or damage that may be caused by the alteration? If no compensation agreement has been made, how will compensation be determined? 12. CONTRACTORS AND SUB-CONTRACTORS (name, address and functions) Same as STUDIES UNDERTAKEN TO DATE (list and attach copies of studies, reports, research, etc.) Not applicable. 14. THE FOLLOWING DOCUMENTS MUST BE INCLUDED WITH THE APPLICATION FOR THE REGULATORY PROCESS TO BEGIN Supplementary Questionnaire (where applicable: see section 5) n/a Yes No If no, date expected Inuktitut/English Summary of Project Yes No If no, date expected Application fee $30.00 (c/o of Receiver General for Canada) Yes No If no, date expected 15. PROPOSED TIME SCHEDULE Annual (or) _x_ Multi Year Start Date: August 2009 Completion Date: October 2010 Page 3 of 9
4 Name (Print) Title (Print) Signature Date For Nunavut Water Board use only APPLICATION FEE Amount: $ Receipt No.: WATER USE DEPOSIT Amount: $ Receipt No.: Page 4 of 9
5 Rankin Inlet Fuel Storage Facility Upgrade and Expansion Tank Hydrostatic Testing Procedure 1- Site of local area identifying areas of impact. The area of impact is the Rankin Inlet Fuel Storage Facility and the sea hose connection pipeline, see attached appendix A. 2- Location of water source Salt water from Rankin Inlet Beach located close to the sea hose connection 3-Total quantity of water to be withdrawn from source cubic meters. 4-Method to minimize volumes of water sources. The same water will be pumped from tank to tank. 5-Method of monitoring volumes of fresh water sources. The water will be pumped into known tank volumes. 6-Amount, method of disposal and location of waste and sludge to be disposed of. Prior to start filling, the tanks will be completely drained; cleaned using a pressure washer, and the dirty water used during the pressure washing will be stored in drums and considered as sludge. If hydrophobic pads or floor dry are used, they will be stored in drums. The drums will be shipped out by sealift to Montreal for proper disposal. Prior to discharge the water, a sample will be taken for the tank drain valve and sent to a laboratory for testing to ensure the water is not contaminated. The water (salt or fresh) well be pumped back through the temporary flexible hose running by the pipeline and be discharge through a solid particle collector as shown on Appendix C. The solid particle collector will discharge in the Repulse Bay. We expect to have approximately 24 drums of waste to be shipped south. 7- Provide a spill contingency action plan. All the tanks are located in a containment dyke with an HDPE liner that can contain move volume then the biggest tank. In the event of a spill, the water will be immediately pumped back in the tank. 8-Details of work to be completed and restoration work required. The project consists in building one new tank 3200cum vertical tank, relocate/refurbish two 947cum vertical tanks, and relocate two 92cum horizontal tanks. See attached Sketch 1 for the new tank farm layout. On completion all tanks will be hydrostatically tested. The tank containment will be enlarged, and a new HDPE Liner installed. New dispenser building and operator s shelter will be installed. 9-Waste disposal alternatives for contaminated liquid waste. Cleaning materials, absorbent material and sludge. All will be packed in drums and sent by sealift to Montreal for proper disposal. 10- Location of sumps or holding cells in relation to existing water bodies. Sumps and holding cell are located in the tank farm dyke. 11-Will these undertakings interfere with existing water users or waste depositors? No. Page 5 of 9
6 Marc Losier Technical Coordinator Mosher Engineering Limited 71 Wright Ave, Dartmouth, NS, B3B 1H4 Ph: (902) Fax: (902) Cell (902) Page 6 of 9
7 Appendix A Aerial View of Rankin Inlet Tank Farm Page 7 of 9
8
9
10 Appendix B Tender Drawing No. C3 Proposed Layout Page 8 of 9
11
12 Solid Particle Collector Appendix C Page 9 of 9
13 SKETCH #4 4" INLET 4" CROSS CONNECTION 4" OUTLET TEST WATER FROM TESTED TANK DISCHARGE TO PAWN HEAVY SOLID PARTICLE COLLECTS IN THE BOTTOM OF THE DRUMS 45 GAL DRUM 45 GAL DRUM TEST WATER SOLID PARTICLE COLLECTOR
Civil Engineering Sector Labour-Management Health and Safety Committee
PROCEDURE FOR THE STORAGE AND HANDLING OF FUEL ON CONSTRUCTION SITES Civil Engineering Sector Labour-Management Health and Safety Committee July 2008 PROCEDURE FOR THE STORAGE AND HANDLING OF FUEL ON CONSTRUCTION
More informationBest Management Practices
for The City of Paso Robles is required to implement a Phase II Municipal Water Program in order to reduce or eliminate the pollutants that enter our waterways from both storm water and non-storm water
More informationSPILL PREVENTION PLAN
SPILL PREVENTION PLAN ASPHALT BATCH PLANT NIRB FILE # 15XN046 Presented to NIRB September 2015 TABLE OF CONTENTS PAGE 1. SPILL CONTROL PLAN... 1 1.1 RESPONSE EQUIPMENT... 1 1.2 GENERAL PROCEDURES IN CASE
More informationAppendix VIII: Spill Prevention, Control and Countermeasure (SPCC) Plans
Appendix VIII: Spill Prevention, Control and Countermeasure (SPCC) Plans Background What is a Spill Prevention, Control and Countermeasure (SPCC) Plan? An SPCC plan is a written document that describes
More informationFlorida Department of Environmental Protection
Florida Department of Environmental Protection Background Mobile vehicle and equipment washing involves washing at a location where vehicles are based (such as a trucking company, warehouse, bus station,
More informationSPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN
SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN XXXX FARM (CITY OR COUNTY), MICHIGAN CONTACT (NAME), OWNER CERTIFICATION: I hereby certify that I have examined the facility, and being familiar with the
More informationMEMORANDUM. Further discussion regarding the Community s solid waste facility is described further in this memorandum.
MEMORANDUM File: Sanikiluaq Improvement of the Existing Wastewater Treatment Facility To: Government of Nunavut Department of Community and Government Services Attention: Mr. Grigor Hope,, Project Officer
More informationGood Housekeeping Practices for DPW/Fleet Maintenance Facilities
Good Housekeeping Practices for DPW/Fleet Maintenance Facilities Kevin P. Walker C&S Engineers, Inc. Best Management Practices Best Management Practices (BMPs) are measures and/or controls used to prevent
More informationDRAFT Guidelines for Manually Diverting Outdoor Wastewater to the Sanitary Sewer
Only RAIN down the Storm Drain... DRAFT Guidelines for Manually Diverting Outdoor Wastewater to the Sanitary Sewer This publication applies to you if: You generate wastewater outdoors, and The wastewater
More informationOil and Gas Exploration and Production Oil and gas exploration and production... 22a-472-1
Department of Environmental Protection Sec. 22a-472 page 1 (4-97) TABLE OF CONTENTS Oil and Gas Exploration and Production Oil and gas exploration and production... 22a-472-1 Department of Environmental
More informationKEEPING PESTICIDES OUT OF WATER LOCAL ENVIRONMENT RISK ASSESSMENT FOR PESTICIDES (LERAP)
KEEPING PESTICIDES OUT OF WATER LOCAL ENVIRONMENT RISK ASSESSMENT FOR PESTICIDES (LERAP) Making it work together Introduction Most pesticide users are aware of the need for care in selecting and applying
More informationSafety Manual Title: Spill Prevention & Response Review Date: 6/1/2014
Operation s Purpose The purpose of this plan is to document spill prevention and response requirements. Each Elkhorn Construction, Inc. jobsite will develop a spill prevention and response plan based on
More informationCity of Shelbyville Site Inspection Checklist
City of Shelbyville Site Inspection Checklist General Information Project Name: KYR10 Permit Number: Date: Project Location: Contractor: Conractor Representative: Inspector's Name: Title: Signature : Weather
More informationSpill Control Prevention Plan (SCPP)
Spill Control Prevention Plan (SCPP) FACILITY INFORMATION PLEASE PRINT Facility Name: Mailing Address: Physical address if different: Owner Name: Owner Address: Primary Contact Name: Work Phone Number:
More informationAPPENDIX O. Spill Prevention and Emergency Response Plan. G3 Terminal Vancouver Port Metro Vancouver Project Permit Application APPENDIX O
APPENDIX O Spill Prevention and Emergency Response Plan APPENDIX O G3 Terminal Vancouver Port Metro Vancouver Project Permit Application G3 TERMINAL VANCOUVER: PORT METRO VANCOUVER SPILL PREVENTION AND
More informationTHE CORPORATION OF THE CITY OF COURTENAY BYLAW NO. 2182. A bylaw to amend Storm Sewer Bylaw No. 1402, 1986
THE CORPORATION OF THE CITY OF COURTENAY BYLAW NO. 2182 A bylaw to amend Storm Sewer Bylaw No. 1402, 1986 The Council of the Corporation of the City of Courtenay in open meeting assembled enacts as follows:
More informationWaste Handling & Disposal
Objectives Cover Contain Educate Reduce/Minimize Product Substitution Description Improper storage and handling of solid wastes can allow toxic compounds, oils and greases, heavy metals, nutrients, suspended
More informationUTILITIES DEPARTMENT
UTILITIES DEPARTMENT Dear Business Owner, As a Business owner or manager you know how important it is to provide a safe and reliable service or product. Similarly, the City of Brighton Utilities Department
More informationEnvironmental Management System Procedures
Environmental Management System s Plan Title Oils and Oil Contaminated Items Delivery, Storage, Use and Disposal Ref No Op-Proc-71 Related Documents EMS-Plan-7 Op-Proc-72 EMS-F-71 EMS-F-72 Record of Revisions
More informationENVIRONMENTAL CODE OF PRACTICE FOR CONCRETE BATCH PLANT & ROCK WASHING OPERATIONS
ENVIRONMENTAL CODE OF PRACTICE FOR CONCRETE BATCH PLANT & ROCK WASHING OPERATIONS PREPARED BY: DEPARTMENT OF ENVIRONMENT AND LANDS INDUSTRIAL ENVIRONMENTAL ENGINEERING DIVISION APRIL 16, 1992 - TABLE OF
More informationKurt Wilson Louisiana Dept. of Environmental Quality Business & Community Outreach Division Small Business/Small Community Assistance Program
Kurt Wilson Louisiana Dept. of Environmental Quality Business & Community Outreach Division Small Business/Small Community Assistance Program LDEQ Water Regulations Spill Prevention and Control (SPC) Authorized
More informationConstruction Site Inspection Checklist for OHC000004 By making use of some simple Best Management Practices (BMPs) a construction site operator can
Construction Site Inspection Checklist for OHC000004 By making use of some simple Best Management Practices (BMPs) a construction site operator can do his or her share to protect Ohio's water resources
More informationAppendix J3 - Outline Fuel Spill Contingency Response Plan. Control room receives call on fuel spill from staff or public
Appendix J3 - Outline Fuel Spill Contingency Response Plan Control room receives call on fuel spill from staff or public Initial Actions to be taken after Fuel Spill reported Identification of the source
More informationHow To Prevent Over Water Activities
Objectives Cover Contain Educate Reduce/Minimize Product Substitution Description Over-water activities occur at boat and ship repair yards, marinas, and yacht clubs. The discharge of pollutants to receiving
More informationFats, Oil and Grease. Best Management Practices Manual. Information, Pollution Prevention, and Compliance Information For Food Service Facilities
Fats, Oil and Grease Best Management Practices Manual Information, Pollution Prevention, and Compliance Information For Food Service Facilities Pinellas County Utilities Water Quality Management Division
More informationGUIDANCE FOR DEVELOPMENT OF SPILL AND SLUG PREVENTION CONTROL PLANS AND FACILITIES FOR THE CITY OF ATTLEBORO SEWER USERS
Company Name: Address: The City of Attleboro s Rules and Regulations for the use of Wastewater Facilities require each user to provide protection from accidental discharge of prohibited materials and substances
More informationA.M. FREDERICKS UNDERWRITING MANAGEMENT LTD. Limited Pollution Liability Insurance Questionnaire (Forming part of the Liability Survey of Hazards)
A.M. FREDERICKS UNDERWRITING MANAGEMENT LTD. Limited Pollution Liability Insurance Questionnaire (Forming part of the Liability Survey of Hazards) 1. Name of Applicant Date Agent/Broker Proposed Policy
More informationOIL CONTAINMENT AND SPILL MITIGATION M-04 ISSUE: F SEPTEMBER 2001
OIL CONTAINMENT AND SPILL MITIGATION Page: 1 of 8 OIL CONTAINMENT AND SPILL MITIGATION M-04 ISSUE: F SEPTEMBER 2001 Prepared and Maintained by: J Versluys Maintenance Manager Authorised and Approved by:
More informationN.J.A.C. 7:9A Amendments
N.J.A.C. 7:9A Amendments The Standards for Individual Subsurface Sewage Disposal Systems Issues Encountered in Our First Year NJEHA March 5, 2013 History of the Changes Proposed on March 7, 2011 Comment
More informationBASEMENT FLOODING. Prevention Guide for. Homeowners
BASEMENT FLOODING Prevention Guide for Homeowners 1 Did You Know? Floods are the most common hazards in Canada. Water damage is a common cause of loss for homeowner insurance. A heavy rainfall can result
More informationProtect Your Home From Flooding. A guide for Lethbridge Residents
Protect Your Home From Flooding A guide for Lethbridge Residents Every year, millions of litres of water flow into the City of Lethbridge s stormwater and wastewater collection systems from residential
More informationEnvironmental Regulations & Best Management Practices CARPET CLEANING OPERATIONS. Carpet Cleaning Operations in the Capital Regional District
Environmental Regulations & Best Management Practices CARPET CLEANING OPERATIONS Carpet Cleaning Operations in the Capital Regional District ENVIRONMENT ONMENTAL AL REGULATIONS & BEST MANAGEMENT PRACTICES
More informationCOMMERCIAL BUSINESS LICENSE APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT Code Administration Division 129 North Second Street, 2nd Floor Yakima, Washington 98901 (509) 575-6126 Fax (509) 576-6576 codes@yakimawa.gov www.buildingyakima.com COMMERCIAL
More informationInvestigms 2014 - The Mackenzie Valley Industrialrial Facility Inspection
6 October 2014 De Beers Group of Companies Suite 300, 5020 49 th Street Yellowknife, NT X1A 1P8 Water Licence MV2011L2-0004 Attn: Erica Bonhomme Environment Manager Re: September 10 th 2014 GNWT Lands
More informationWaste Oil Handling, Spill Containment & Lighting
58 Waste Oil Handling, Spill Containment & Lighting 372000 SAMOA Mobile Waste Oil Drainer & Extractor Drains and/or extracts waste oil from cars and light commercial vehicles Drain bowl capacity of 20
More informationDIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY. August 2012
DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY August 2012 SECTION 2 The storage requirements in Directive 055 apply to upstream petroleum facilities, well sites, and pipelines
More informationCITY OF WASHINGTON SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN
CITY OF WASHINGTON SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN Adopted October 5, 2009 Table of Contents Chapter Description Page 1 Facility Descriptions... 3 1.1 Municipal Power Plant, 1001 Park
More informationSECTION 15 FLOODPLAIN MANAGEMENT
SECTION 15 15.1 Purpose Certain areas of the City of Gardiner, Maine, are subject to periodic flooding, causing serious damages to properties within these areas. Relief is available in the form of flood
More informationIncident Reporting Requirements
Incident Reporting Requirements Directive PNG014 February 2016 Revision 1.0 Governing Legislation: Acts: The Oil and Gas Conservation Act The Pipelines Act, 1998 Regulations: The Oil and Gas Conservation
More informationFact sheet 6: for farmers
Fact sheet 6: for farmers Fuel Oil Storage June 2013 Are you planning to substantially alter your fuel oil store, or add a new one? If so, this fact sheet will help you meet the requirements of The Water
More informationCONTENT COPY OF ORIGINAL
Ministry of the Environment Ministère de l Environnement Access Self Storage Inc. 100 Canadian Road Toronto, Ontario M1R 4Z5 AMENDED ENVIRONMENTAL COMPLIANCE APPROVAL NUMBER 8701-9A4QC7 Issue Date: August
More informationSEPTIC TANKS FOR THE COLLECTION & SETTLEMENT OF DOMESTIC SEWAGE
SEPTIC TANKS FOR THE COLLECTION & SETTLEMENT OF DOMESTIC SEWAGE Let us help! Free professional site visit with friendly support and advice. helpingyou@klargester.com to make the right decision or call
More informationSpill Contingency Plan. Hamlet of Aklavik
Spill Contingency Plan Hamlet of Aklavik Section 1.8 There is 1 hazardous materials storage areas in the Hamlet of Aklavik, Table 1.2 presents a list of hazardous materials onsite, the type of storage
More informationDemo Permit Guide For Homeowners
Demo Permit Guide For Homeowners Building Services Tel: 705-436-3710 ext. 3504 or 3506 Fax: 705-436-7120 2101 Innisfil Beach Road, Innisfil, ON L9S 1A1 Website: www.innisfil.ca A Demo Permit Guide for
More informationYOUR GUIDE TO PRACTICAL METHODS THAT PROTECT
POLLUTION PREVENTION PRACTICES FOR SURFACE CLEANING YOUR GUIDE TO PRACTICAL METHODS THAT PROTECT OUR LOCAL CREEKS, RIVERS, LAKES, AND THE SAN FRANCISCO BAY. DECEMBER 2004 CREATED BY THE NAPA-SOLANO-SONOMA
More informationMAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT
Record MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT Abandoned Gravity Private Combined Gravity Private Foul Gravity Private Surface Water Gravity Public Combined Gravity Public Foul Gravity Public
More informationPOLLUTION PREVENTION FACT SHEET: AUTOMOBILE MAINTENANCE
POLLUTION PREVENTION FACT SHEET: AUTOMOBILE MAINTENANCE Description This pollution prevention measure involves creating a program of targeted outreach and training for businesses involved in automobile
More informationMAINTENANCE OF SMALL WATER SUPPLY, SANITATION AND IRRIGATION SCHEMES
MAINTENANCE OF SMALL WATER SUPPLY, SANITATION AND IRRIGATION SCHEMES John van Rijn INDEVELOPMENT MAINTENANCE OF SMALL WATER SUPPLY, SANITATION AND IRRIGATION SCHEMES Any part of this publication may be
More informationABOVE-GROUND STORAGE TANKS
ABOVE-GROUND STORAGE TANKS Above-ground storage tanks in Georgia are regulated by the State Fire Marshall and by the EPA. Above-ground tanks containing 1,100 gallons or less do not require any secondary
More informationConstruction Specification for Sewer Bypass Flow Pumping
Engineering and Construction Services Division Standard Specifications for Sewers and Watermains TS 4.01 April 2013 Pumping Table of Contents TS 4.01.01 SCOPE... 2 TS 4.01.02 REFERENCES... 2 TS 4.01.03
More informationWASTE WATER TREATMENT for surface treatment applications
WASTE WATER TREATMENT for surface treatment applications Effluent an important cost factor Effluent cannot be avoided Water and compound are essential for vibratory mass finishing. During the finishing
More informationChapter 8 Water and Sewage Systems
Chapter 8 Water and Sewage Systems Proper sanitary controls pertaining to the water supply system and sewage and liquid waste disposal systems are necessary in all types of food establishments to prevent
More informationUDOT SPILL PREVENTION and RESPONSE PLAN for CONSTRUCTION SITES
UDOT SPILL PREVENTION and RESPONSE PLAN for CONSTRUCTION SITES February 2014 The plan contained in the following pages was developed in part from UDOT Construction Division s Safety and Health Manual,
More informationFloodplain Development Land Use Review
COMMUNITY DEVELOPMENT DEPARTMENT Planning Division P.O. Box 490 333 Broadalbin Street SW Albany, OR 97321 Phone 541-917-7550 Fax 541-791-0150 www.cityofalbany.net Floodplain Development Land Use Review
More informationStandard terms and conditions
Standard terms and conditions INTRODUCTION For the provision of a water service (Water Supply, Wastewater and Drainage) Under Section 73(2)(a) of the Water Services Act 2012, landowners may be entitled
More informationONSITE WASTEWATER TREATMENT SYSTEM Property Transfer Certification Instructions and Inspection Report
ONSITE WASTEWATER TREATMENT SYSTEM Property Transfer Certification Instructions and Inspection Report These instructions are for homeowners and inspectors completing the onsite wastewater treatment system
More informationWASTEWATER TREATMENT OBJECTIVES
WASTEWATER TREATMENT OBJECTIVES The student will do the following: 1. Define wastewater and list components of wastewater. 2. Describe the function of a wastewater treatment plant. 3. Create a wastewater
More informationMarch 2006 DIVISION 3 - CW 2140-R3 TABLE OF CONTENTS
March 2006 CW 2140 - SEWER AND MANHOLE CLEANING TABLE OF CONTENTS 1. DESCRIPTION... 1 1.1 General... 1 1.2 Definitions... 1 1.3 Referenced Standard Constructions... 1 3. CONSTRUCTION METHODS... 1 3.1 High
More informationFLOOD DAMAGE PREVENTION ORDINANCE
FLOOD DAMAGE PREVENTION ORDINANCE SECTION 1.0 STATUTORY AUTHORIZATION, FINDINGS FO FACT, PURPOSE, AND OBJECTIVES 1.1 STATUTORY AUTHORIZATION The Legislature of the State of Washington has in RCW delegated
More informationHazardous Waste Determination and Management Plan
Hazardous Waste Determination and Management Plan Prepared By: Triumvirate Environmental Developed: November 2014 Updated: Program Approval Associate Vice President of Public Safety & Administrative Services
More informationEXISTING STRUCTURES 1) FAIR MARKET VALUE OF STRUCTURE(s) BEFORE IMPROVEMENT: 2) COST OF IMPROVEMENTS:
Date Received: Received By: Project/Permit Number: Fee: (To be Completed by MOA) FLOOD HAZARD PERMIT APPLICATION (Please fill out application completely; Indicate NA if necessary. Property information
More informationFOOD SERVICE FACILITIES Best Management Practices Stormwater Management Program City of Bluff City P.O. Box 70, Bluff City, TN 37618 423-538-7144
FOOD SERVICE FACILITIES Best Management Practices Stormwater Management Program City of Bluff City P.O. Box 70, Bluff City, TN 37618 423-538-7144 This document may be printed and used for reference by
More informationAppendix J Spill Prevention and Response Plan
Appendix J Spill Prevention and Response Plan This page intentionally left blank SPILL PREVENTION AND RESPONSE PLAN THE LUCERNE SOLAR PROJECT SAN BERNARDINO COUNTY, CALIFORNIA Revision 1 dated: January
More informationAsbestos Storage Facility Plan Examples
Asbestos Storage Facility Plan Examples The purpose of this document This document contains examples of what an operational plan, plans and specification, contingency plan and closure plan should look
More informationTemporary Batch Plants
Categories EC SE TC WE NS WM Erosion Control Sediment Control Tracking Control Wind Erosion Control Non-Stormwater Management Control Waste Management and Materials Pollution Control Legend: Primary Category
More informationFUEL & OIL SPILL CONTINGENCY PLAN
FUEL & OIL SPILL CONTINGENCY PLAN For Labiche 2006 2D SEISMIC PROGRAM Summer 2006 FUEL AND OIL SPILL CONTINGENCY PLAN NORTHWEST TERRITORIES & YUKON INTRODUCTION Purpose of Plan The purpose of this plan
More informationApplication & Customer Site Management Plan to Use Recycled Water from a Standpipe
Application & Customer Site Management Plan to Use Recycled Water from a Standpipe This application forms part of Western Waters Recycled Water Temporary Supply Agreement (TSA) as a Customer Site Management
More informationEnvironmental guidelines for preparation of an Environment Management Plan
Environmental guidelines for preparation of an Environment Management Plan Environment Protection Authority MAY 2013 Australian Capital Territory, Canberra 2013 This work is copyright. Apart from any use
More informationseptic systems What is a Septic System? How does a Septic System Work?
septic systems What is a Septic System? A septic system is a private sewage treatment system. They are common in rural areas where there are no municipal sewage pipes for homes, farms, businesses or other
More informationRepair and Renew Grant. Croydon RRG Scheme
Repair and Renew Grant Croydon RRG Scheme Development & Environment April 2014 Croydon Repair and Renew Grant Scheme Support for independent businessess and property owners affected by flooding December
More informationACTIVITY NAME. Training Requirements for Spill Prevention Control and Countermeasures (SPCC) 40 CFR Part 112 Naval Air Station Corpus Christi Texas
ACTIVITY NAME Training Requirements for Spill Prevention Control and Countermeasures (SPCC) 40 CFR Part 112 Naval Air Station Corpus Christi Texas CY 2014 BOTTOM LINE UP FRONT To prevent oil discharges
More informationChapter 2 Stormwater Pollution Prevention Plan (SWPPP) for Park Operations
SWPPP for Park Operations 2 Chapter 2 Stormwater Pollution Prevention Plan (SWPPP) for Park Operations Bordered by Lake Washington & Lake Sammamish, the City of Bellevue has more than 60 miles of streams,
More informationCompliance Guidance for Motor Vehicle Waste Disposal Wells in Oregon September 2015
Compliance Guidance for Motor Vehicle Waste Disposal Wells in Oregon September 2015 Underground Injection Control Program 700 NE Multnomah Street Suite 600 Portland, OR 97232 Phone: 503-229-6371 800-452-4011
More informationIC24. DISPOSAL OF WASTEWATER GENERATED BY MOBILE BUSINESSES AND OUTDOOR ACTIVITIES
IC24. DISPOSAL OF WASTEWATER GENERATED BY MOBILE BUSINESSES AND OUTDOOR ACTIVITIES BEST MANAGEMENT PRACTICES (BMP) A BMP is a technique, measure, or structural control that is used for a given set of conditions
More informationVEHICLE SERVICE FACILITIES. Best Management Practices
VEHICLE SERVICE FACILITIES Best Management Practices Chapter 1 of the Best Management Practices Manual for the City s Storm Water Management Program Public Works Department 809 Center Street, Santa Cruz,
More informationItem No. 10.1.1 Halifax Regional Council September 28, 2010
PO Box 1749 Halifax, Nova Scotia B3J 3A5, Canada Item No. 10.1.1 Halifax Regional Council September 28, 2010 TO: Mayor Kelly and Members of Halifax Regional Council SUBMITTED BY: Mike Labrecque, Acting
More informationSUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES TOXIC/HAZARDOUS MATERIAL TRANSFER FACILITY DESIGN GUIDELINES
SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES TOXIC/HAZARDOUS MATERIAL TRANSFER FACILITY DESIGN GUIDELINES 1.0 GENERAL 1.1 Article 12 of the Suffolk County Sanitary Code requires that toxic/hazardous material
More informationBest Environmental Management Practices
Save money and prevent costly utility increases by protecting our environment and our Publicly Owned Treatment Works. Read this pamphlet to find out how. Vehicle Service Facility Best Environmental Management
More informationInstallation and Service Instructions. Neutralization System Part no. 7441823 Grünbeck part no. 410480
Installation and Service Instructions for use by heating contractors Neutralization System Part no. 7441823 Grünbeck part no. 410480 Safety and Installation Requirements Please ensure that these instructions
More informationDischarge of Water & Waste from Marine Vessels Standards & Regulations (MARPOL Convention)
Discharge of Water & Waste from Marine Vessels Standards & Regulations (MARPOL Convention) August 2010 Disclaimer: The standards & regulations provided here are attributable to the named source and are
More informationPollution Prevention And Best Management Practices For Dry Cleaners Operating In Broward County
FORWARD In 1991, the Broward County Environmental Protection and Growth Management Department, who was then known as the Department of Natural Resource Protection (DNRP), initiated the development of Pollution
More informationENERGY, MINES AND RESOURCES (EMR) ASSESSMENT REGULATORY GUIDE:
Energy, Mines and Resources Energy, Mines and Resources Energy, Mines and Resources Energy, Mines and Resources ENERGY, MINES AND RESOURCES (EMR) ASSESSMENT REGULATORY GUIDE: A guide to explain how EMR
More informationSPILL PREVENTION, CONTROL, AND COUNTER MEASURES PLAN (SPCC)
SPILL PREVENTION, CONTROL, AND COUNTER MEASURES PLAN (SPCC) UNIVERSITY RISK MANAGEMENT Occupational and Health Programs 19 Hagood Avenue, Suite 908 Charleston SC 29425 843-792-3604 Revised: June 2015 Spill
More informationPollution Incident Response Management Plan (PIRMP)
Pollution Incident Response Management Plan (PIRMP) For NSW Ports For Construction of Berth 103 Stage 2 Extension WATERWAY CONSTRUCTIONS PTY LTD ABN 74 061 311 395 Po Box 290, Annandale NSW 2038 TELEPHONE:
More informationThe Town of Lakeshore Basement Flooding Information to Residents
The Town of Lakeshore Basement Flooding Information to Residents The following information is intended for residents that have homes connected to Municipal storm and sanitary sewers. However, rural residents
More informationSPILL CONTAINMENT AND CONTROL PLAN
SPILL CONTAINMENT AND CONTROL PLAN PUD NO. 1 TREATMENT PLANT 1257 GLASS ROAD PORT ANGELES, WASHINGTON PUD No. 1 Treatment Plant 2431 East Highway 101 P.O. Box 1090 Port Angeles, WA 98362 Facility Description:
More informationFor an Incidental Oil Spill:
Table 2 Oil Spill Procedural Checklist In the event of a spill or accidental release of fuel oil or other combustible material on premises, WWU personnel follow the procedural checklist outlined below.
More informationFact sheet 6: for farmers
Fact sheet 6: for farmers Fuel Oil Storage February 2011 Are you planning to substantially alter your fuel oil store, or add a new one? If so, this fact sheet will help you meet the requirements of The
More informationK A N S A S DEPARTMENT OF HEALTH AND ENVIRONMENT PERMIT APPLICATION FOR A RECLAMATION FACILITY. 1. Applicant's Name
K A N S A S DEPARTMENT OF HEALTH AND ENVIRONMENT PERMIT APPLICATION FOR A RECLAMATION FACILITY 1. Applicant's Name Address (Street or Rural Route) (City & State) (Zip) Person to contact Title Phone Fax
More informationContingency Plan. Community College of Denver - Auraria Campus Facility Name
Contingency Plan Community College of Denver - Auraria Campus Facility Name This plan is reviewed annually and amended whenever changes occur that will significantly affect the ability of this facility
More informationALLEGANY WIND POWER PROJECT CONSTRUCTION SPILL PREVENTION PLAN
ALLEGANY WIND POWER PROJECT CONSTRUCTION SPILL PREVENTION PLAN Best Management Practices (BMPs) will be implemented during construction of the Allegany Wind Power Project to prevent and contain spills.
More informationHomeowners and Home Buyers Guide to Wells and Private Sewage Systems
Homeowners and Home Buyers Guide to Wells and Private Sewage Systems What every homeowner should know about living with a well and a private sewage system. YOUR ENVIRONMENTAL SYSTEMS Out of sight out of
More informationCHAPTER 62-740 PETROLEUM CONTACT WATER
CHAPTER 62-740 PETROLEUM CONTACT WATER 62-740.010 Declaration of Intent (Repealed) 62-740.020 Applicability 62-740.030 Definitions 62-740.040 General 62-740.100 Management Practices for Producers of PCW
More informationSEPTIC SYSTEM. Taking care of your. ... what you need to know
Taking care of your SEPTIC SYSTEM... what you need to know For more information, please call: WATER & WASTE MANAGEMENT PROGRAM (909) 387-4666 Visit our web site: www.sbcounty.gov/dehs A:\Septic System
More informationGrease Trap Maintenance, Procedures and Cleaning Logs
SAWS Grease Reduction Program Grease Trap Maintenance, Procedures and Cleaning Logs Don t Feed the Grease Monster Best Management Practices for Commercial Food and Restaurant Facilities Train kitchen staff
More informationENVIRONMENTAL IMPACT ASSESSMENT PROCESS
ENVIRONMENTAL IMPACT ASSESSMENT PROCESS PROPOSED SOLIDS REMOVAL AND TREATMENT FACILITIES UPGRADE AT THE SOUTHERN WASTE WATER TREATMENT WORKS, MEREWENT, IN THE ETHEKWINI METROPOLITAN MUNICIPALITY BACKGROUND
More informationManaging Floor Drains and Flammable Traps
Managing Floor Drains and Flammable Traps Contents: Problem... 1 Solution... 2 Maintenance... 2 Waste Management Options... 2 For More Information... 4 BMP Chart... 5 This fact sheet discusses recommended
More informationDrum Dispensing Stations
Drum Dispensing Stations O Safely Dispense from 55 Gallon Drums over a Spill Compliant Sump. 1-2-and 4 drum models available Drums are securely held on racks by galvanized positioners Sump and frame constructed
More informationTOWN OF MANSFIELD STORMWATER POLLUTION PREVENTION PLAN. for the TOWN GARAGE (230 CLOVER MILL ROAD) REVISED JANUARY, 1997 REVISED SEPTEMBER, 2003
TOWN OF MANSFIELD STORMWATER POLLUTION PREVENTION PLAN for the TOWN GARAGE (230 CLOVER MILL ROAD) REVISED JANUARY, 1997 REVISED SEPTEMBER, 2003 REVISED JANUARY, 2005 REVISED MARCH, 2007 REVISED MAY, 2011
More informationResidential Plumbing BCN 1058
Residential Plumbing BCN 1058 CHAPTER 7 Plumbing Fixtures and Sizing the Drain, Waste, and Vent System MICHAEL KNOTEK 74 Plumbing Fixtures and Sizing the Drain, Waste, and Vent System PLUMBING FIXTURES
More information