1 Temperature Sensors with ATEX and IECEx approval, Ex e type ATEX / INSTRUMENTS
2 Temperature sensors with ATEX and IECEx approval, Ex e type Table of contents page About the manufacturer SKS Group 3 SKS Automaatio 3 SKS Sensors 3 General approval information ATEX certification 4 IECEx certification 4 ISO9001:2008 certification 5 Products and product certificates ATEX IECEx WT-BAJONETTI-6/XXX-YYYY/TDT-4J-KLA-EX X X 8 2XWT-BAJONETTI-8/XXX-YYYY/TDT-4J-KLA-EX X X 15 WT-KAAPELI-6/XXX-YYYY/TDT-4J-KLA-EX X X 22 WT-KAAPELI-6-XXX-YYYY/SDS-2J-KLA-EX X 29 2XWT-KAAPELI-6/XXX-YYYY/TDT-4J-KLA-EX X X 32 WT-MI-302-6/XXXXX-200/FEP-4J-KLA-EX X 39 WT-MI /FEP-4J-KLA-EX X 42 WT-MI-302-6/ /FEP-4J-KLA-EX X 45 WT-MI-302-3/ /FEP-4J-KLA-EX X 48 EX = ATEX and/or IECEx certified sensor type KLA = Pt100 resistor tolerance class A 2J, 4J = number of connection wires / resistor FEP, SDS, TDT = connection cable sheath material YYYY, 200 = connection cable length mm XXX, XXXXX, 2000, 1000 = sensor element length mm 3, 6, 8 = sensor element diameter mm BAJONETTI, KAAPELI, MI-302 = sensor structure, design WT = 1 Pt100 resistor, 2XWT = 2 Pt100 resistor SKS Sensors is a registered trade mark of SKS Automaatio Oy
3 SKS Group SKS is a comprehensive technical supplier having solid expertise and a comprehensive product range to be offered to the Finnish automation and machine building industry. The SKS Group consists of following companies: SKS Group Oy (Parent Company) SKS Automaatio Oy (Automation and Electrical Components) SKS Connecto Oy (Cable Harness, Design and Assembly Services) SKS Control Oy (Electric Drives and Motion Control Systems) SKS Mechatronics Oy (Stage Technology Systems) SKS Mekaniikka Oy (Mechanical and Power Transmission Components) SKS Toijala Works Oy (Contract Manufacturing) SKS China Co. Ltd. (China) SKS Connecto Polska Sp. z. o.o (Poland) SKS Group representative office St. Petersburg (Russia) SKS Sweden AB (Gears, Sweden) SKS Tehnika OÜ (Estonia). The SKS Group turnover in 2014 was million EUR with a staff of more than 685 employees. The operations have been ISO 9002 certified since January 1996, presently this certificate is updated to ISO 9001:2008. SKS Automaatio SKS Automaatio Oy is a member of the SKS Group. SKS Automaatio Oy manufactures, imports and sells electrical automation components. In addition to that we offer various services for automation industry and machine builders. Turnover was 16.4 million EUR in Products and services Our product groups include Components for Process Automation, Components and Special Cables, Cable Connectors and Connector Systems, Electrification and Control Systems. For the process industry sector we concentrate on temperature measurement. Our experience of instrumentation is focused on our own manufacturing of temperature sensors, and all the components needed within. SKS Sensors SKS Automaatio Oy offers state-of-the-art technology for temperature measuring sensor manufacturing. In addition to the wide standard products range we also provide individual, customer specific total solutions. The principles of our services are fast and high quality deliveries as well as cost-effectiveness and low risk for the customer. Quality with over 20 years of experience The SKS Sensors temperature sensors are manufactured with uncompromising expertise for the use of the process and machine building industries. SKS Automaatio is a temperature sensor manufacturing pioneer with its 20 years experience. The own manufacturing guarantees the short delivery times also for the application-specific special sensors, e.g. for our range of the ATEX and IECEx certified, Ex e, Ex t and Ex d type sensors for potentially explosive areas. All demanding precision welding is performed with the laser welding equipment in the SKS Connecto production facilities in Hyvinkää, Finland. Our manufacturing operations are ISO 9001:2008 certified. SKS Group Oy has acquired an ATEX quality certificate VTT 02 ATEX Q 001 according to the EU directive 94/9/EC. Our sensor manufacturing operations are also IECEx Quality Assessment Reported according to the standard EN ISO/IEC The IECEx QAR Reference No is FI/VTT/QAR /01. Contact info Mr. Seppo Ojanen, [email protected] SKS Automaatio Oy, Martinkyläntie 50, P.O. Box 122, FI Vantaa, Finland Tel. int , Fax int , [email protected], SKS Sensors is a registered trade mark of SKS Automaatio Oy
4 Ex e / Ex t Temperature sensors Ex e - increased safety, for gas zones 1 or 2 Ex t - dust-protected enclosure, for dust areas. The sensor is an ATEX and/or IECEx-certified, Ex e-type, Pt100 or TC sensor, which can also be used for dust areas, thanks to its dust-protected Ex t enclosure. The measuring circuit can be cabled to a safe area and to a standard device (no ATEX/IECEx requirements). ATEX The SKS Group has been granted an ATEX Quality Assurance Notification (VTT 02 ATEX Q001) as required under EU directive 94/9/EC. The notification, issued by VTT Expert Services Ltd., gives the right to manufacture Ex e and Ex t temperature sensors and to assemble Ex d temperature sensors for use in explosive atmospheres. Please find a copy of the notification on our web site: When ATEX certified sensor types are needed, we will manufacture e.g. Ex II 2 GD Ex e II T1-T6 Ex td A21 IP66 approved sensors. Our currently certified products and copies of the product certificates are presented on next pages. We can manufacture and apply for authorization also for different kind of Ex e-designs, which are to be individually agreed. Please contact our Ex experts. IECEx The SKS Group's sensor manufacturing operations have been assessed in an IECEx Quality Assessment Report (FI/VTT/QAR /01) as required by the EN ISO/IEC standard. The auditing organization was VTT Expert Services Ltd. The report gives the right to manufacture Ex e, Ex t and Ex d type temperature sensors for use in explosive atmospheres and to apply for IECEx approval for them. Please find the IECEx QAR report through our web site: When IECEx product certified sensor types are needed, we will apply for authorization for existing sensor types or produce new ones. IECEx product certificates are applied for on request. SKS Sensors is a registered trade mark of SKS Automaatio Oy
5 Certificate No: AQ-FIN-FINAS Initial certification date: 12 January February 2012 Valid: 10 November September 2018 This is to certify that the management system of SKS Group Oy, SKS Automaatio Oy, SKS Connecto Oy, SKS Control Oy, SKS Mekaniikka Oy, SKS Toijala Works Oy Martinkyläntie 50, Vantaa, Finland and the sites as mentioned in the appendix accompanying this certificate has been found to conform to the Quality Management System standard: ISO 9001:2008 This certificate is valid for the following scope: Sales and marketing, importing, value adding services, storage and distribution of electrical, automation, mechanical and power transmission components, design and service of electrical components, automation components, electric drives and control systems, assembly of temperature sensors, cable harnesses, wire sets, electrifications and busbar trunking systems, manufacturing of welded constructions and system deliveries. Place and date: Espoo, 10 November 2015 For the issuing office: DNV GL Business Assurance Finland Oy Ab Kimmo Haarala Management Representative Lack of fulfilment of conditions as set out in the Certification Agreement may render this Certificate invalid. ACCREDITED UNIT: DNV GL BUSINESS ASSURANCE FINLAND OY AB, Keilasatama 5, Espoo, Finland. TEL: assurance.dnvgl.com
6 Certificate No: AQ-FIN-FINAS Place and date: Espoo, 10 November 2015 Appendix to Certificate SKS Group Oy, SKS Automaatio Oy, SKS Connecto Oy, SKS Control Oy, SKS Mekaniikka Oy, SKS Toijala Works Oy Locations included in the certification are as follows: Site Name Site Address Site Scope SKS Toijala Works Oy (Akaa) Tehtaantie 22, Akaa, Finland Sales and marketing, importing, value adding services, storage and distribution of electrical, automation, mechanical and power transmission components, design and service of electrical components, automation components, electric drives and control systems, assembly of temperature sensors, cable harnesses, wire sets, electrifications and busbar trunking systems, manufacturing of welded constructions and system deliveries. SKS Group Oy, SKS Automaatio Oy, SKS Connecto Oy (Hyvinkää) SKS Group Oy, SKS Automaatio Oy, SKS Connecto Oy, SKS Control Oy, SKS Mekaniikka Oy (Tampere) SKS Group Oy, SKS Automaatio Oy, SKS Mekaniikka Oy (Turku) Varastokatu 10, Hyvinkää, Finland Tammelan Puistokatu 21 A, Tampere, Finland Postikatu 2, Turku, Finland Sales and marketing, importing, value adding services, storage and distribution of electrical, automation, mechanical and power transmission components, design and service of electrical components, automation components, electric drives and control systems, assembly of temperature sensors, cable harnesses, wire sets, electrifications and busbar trunking systems, manufacturing of welded constructions and system deliveries. Sales and marketing, importing, value adding services, storage and distribution of electrical, automation, mechanical and power transmission components, design and service of electrical components, automation components, electric drives and control systems, assembly of temperature sensors, cable harnesses, wire sets, electrifications and busbar trunking systems, manufacturing of welded constructions and system deliveries. Sales and marketing, importing, value adding services, storage and distribution of electrical, automation, mechanical and power transmission components, design and service of electrical components, automation components, electric drives and control systems, assembly of temperature sensors, cable harnesses, wire sets, electrifications and busbar trunking systems, manufacturing of welded constructions and system deliveries. Lack of fulfilment of conditions as set out in the Certification Agreement may render this Certificate invalid. ACCREDITED UNIT: DNV GL BUSINESS ASSURANCE FINLAND OY AB, Keilasatama 5, Espoo, Finland. TEL: assurance.dnvgl.com Page 2 of 3
7 Certificate No: AQ-FIN-FINAS Place and date: Espoo, 10 November 2015 SKS Group Oy, SKS Automaatio Oy, SKS Connecto Oy, SKS Control Oy, SKS Mekaniikka Oy, SKS Toijala Works Oy Martinkyläntie 50, Vantaa, Finland Sales and marketing, importing, value adding services, storage and distribution of electrical, automation, mechanical and power transmission components, design and service of electrical components, automation components, electric drives and control systems, assembly of temperature sensors, cable harnesses, wire sets, electrifications and busbar trunking systems, manufacturing of welded constructions and system deliveries. SKS Connecto Oy (Vieremä) Lasertie 7, Vieremä, Finland Sales and marketing, importing, value adding services, storage and distribution of electrical, automation, mechanical and power transmission components, design and service of electrical components, automation components, electric drives and control systems, assembly of temperature sensors, cable harnesses, wire sets, electrifications and busbar trunking systems, manufacturing of welded constructions and system deliveries. SKS Toijala Works Oy (Viiala) Lumikintie 7, Viiala, Finland Sales and marketing, importing, value adding services, storage and distribution of electrical, automation, mechanical and power transmission components, design and service of electrical components, automation components, electric drives and control systems, assembly of temperature sensors, cable harnesses, wire sets, electrifications and busbar trunking systems, manufacturing of welded constructions and system deliveries. Lack of fulfilment of conditions as set out in the Certification Agreement may render this Certificate invalid. ACCREDITED UNIT: DNV GL BUSINESS ASSURANCE FINLAND OY AB, Keilasatama 5, Espoo, Finland. TEL: assurance.dnvgl.com Page 3 of 3
8 Muutokset sallittu vain sertifikaatin myöntäjän luvalla Changes in the drawing are allowed only by the permission of the authorities who have granted the certificate Piirustus on pätevä dokumentti vain allekirjoitettuna (Tark. ja Hyv.) The drawing is a valid document only with signatures (Chkd. and Appd. ) Kaapeli Cable FEP-Cu-FEP 4x0, C Suojaholkki Protection sleeve AISI 316 PT100 IEC 751 Class A Ilmaraon eriste Air gap insulation Elastomer C Jousi Spring Puristus Compression Johtimien eristeet Wire insulation PTFE C Lämmönjohtopasta Heat conductor paste C 10 Pääteholkki C End sleeve C ATEX- ja IECEx-merkintä ATEX- and IECEx-Marking Kaapeli Cable Jousi Spring Bajonettihattu Bayonet cap Suojaholkki Protection sleeve Ø6 75 YYYY 200 XXX 1xPt100, Luokka A, 2-, 3- ja 4-johdin, standardin IEC 751 mukaan. 1x Pt100, Class A, 2-, 3- and 4-wire, acc. to standard IEC 751. Punainen / Red Punainen / Red Punainen / Red Punainen / Red Punainen / Red - Maksimi käyttölämpötila C - Maksimi mittausvirta 10 ma - Sähköinen kytkentä sovelluksen mukaisesti hyväksyttyyn laitteeseen tai kytkentäkoteloon kytkentä paikan vaatimusten mukaistesti - Max operating temperature C - Max measuring current 10 ma - Electrical connections to approved unit according to application or to terminal box according to requirements at connecting site Tuote / Product θ Valkoinen / White WT-BAJONETTI-6/XXX-YYYY/TDT-4J-KLA-EX θ Valkoinen / White θ Valkoinen / White Valkoinen / White Prosessimateriaali(t) / Process Material(s) Piirt. / Drawn Tark. / Chk Hyväks. -pvm. / Aprvd -Date Suhde / Scal. J.Mikkonen R.Ahonen S.Ojanen Info. Koko / Size SKS Automaatio Oy Martinkyläntie 50, FI Vantaa VTT 14 ATEX 005X A4 Tel IECEx VTT X Fax [email protected] Piirustusnro / Drawing No. Rev AISI 316L
9
10
11
12
13
14
15 Muutokset sallittu vain sertifikaatin myöntäjän luvalla Changes in the drawing are allowed only by the permission of the authorities who have granted the certificate Piirustus on pätevä dokumentti vain allekirjoitettuna (Tark. ja Hyv.) The drawing is a valid document only with signatures (Chkd. and Appd. ) Kaapeli Cable FEP-Cu-FEP 8x0, C Suojaholkki Protection sleeve AISI 316 PT100 IEC 751 Class A Ilmaraon eriste Air gap insulation Elastomer C Jousi Spring Puristus Compression Johtimien eristeet Wire insulation PTFE C Lämmönjohtopasta Heat conductor paste C 10 Pääteholkki C End sleeve C ATEX- ja IECEx-merkintä ATEX- and IECEx-Marking Kaapeli Cable Jousi Spring Bajonettihattu Bayonet cap Suojaholkki Protection sleeve Ø8 75 YYYY 200 XXX 2xPt100, Luokka A, 2-, 3- ja 4-johdin, standardin IEC 751 mukaan. Punainen / Red 2x Pt100, Class A, 2-, 3- and 4-wire, acc. to standard IEC 751. Punainen / Red Punainen / Red Punainen / Red Punainen / Red - Maksimi käyttölämpötila C - Maksimi mittausvirta 10 ma - Sähköinen kytkentä sovelluksen mukaisesti hyväksyttyyn laitteeseen tai kytkentäkoteloon kytkentä paikan vaatimusten mukaistesti - Max operating temperature C - Max measuring current 10 ma - Electrical connections to approved unit according to application or to terminal box according to requirements at connecting site Tuote / Product θ θ Valkoinen / White Sininen / Blue Keltainen / Yellow 2XWT-BAJONETTI-8/XXX-YYYY/TDT-4J-KLA-EX θ θ Valkoinen / White Sininen / Blue Sininen / Blue Keltainen / Yellow θ θ Valkoinen / White Valkoinen / White Sininen / Blue Sininen / Blue Keltainen / Yellow Keltainen / Yellow Prosessimateriaali(t) / Process Material(s) Piirt. / Drawn Tark. / Chk Hyväks. -pvm. / Aprvd -Date Suhde / Scal. J.Mikkonen R.Ahonen S.Ojanen Info. Koko / Size SKS Automaatio Oy Martinkyläntie 50, FI Vantaa VTT 14 ATEX 005X A4 Tel IECEx VTT X Fax [email protected] Piirustusnro / Drawing No. Rev AISI 316L
16
17
18
19
20
21
22 Muutokset sallittu vain sertifikaatin myöntäjän luvalla Changes in the drawing are allowed only by the permission of the authorities who have granted the certificate Piirustus on pätevä dokumentti vain allekirjoitettuna (Tark. ja Hyv.) The drawing is a valid document only with signatures (Chkd. and Appd. ) Kaapeli Cable FEP-Cu-FEP 4x0, C Suojaholkki Protection sleeve AISI 316 PT100 IEC 751 Class A Ilmaraon eriste Air gap insulation Elastomer C Puristus Compression Johtimien eristeet Wire insulation PTFE C Lämmönjohtopasta Heat conductor paste C 10 Pääteholkki C End sleeve C ATEX- ja IECEx-merkintä ATEX- and IECEx-Marking Kaapeli Cable Suojaholkki Protection sleeve Ø6 75 YYYY XXX 1xPt100, Luokka A, 2-, 3- ja 4-johdin, standardin IEC 751 mukaan. 1x Pt100, Class A, 2-, 3- and 4-wire, acc. to standard IEC 751. Punainen / Red Punainen / Red Punainen / Red Punainen / Red Punainen / Red - Maksimi käyttölämpötila C - Maksimi mittausvirta 10 ma - Sähköinen kytkentä sovelluksen mukaisesti hyväksyttyyn laitteeseen tai kytkentäkoteloon kytkentä paikan vaatimusten mukaistesti - Max operating temperature C - Max measuring current 10 ma - Electrical connections to approved unit according to application or to terminal box according to requirements at connecting site Tuote / Product θ Valkoinen / White WT-KAAPELI-6/XXX-YYYY/TDT-4J-KLA-EX θ Valkoinen / White θ Valkoinen / White Valkoinen / White Prosessimateriaali(t) / Process Material(s) Piirt. / Drawn Tark. / Chk Hyväks. -pvm. / Aprvd -Date Suhde / Scal. J.Mikkonen R.Ahonen S.Ojanen Info. Koko / Size SKS Automaatio Oy Martinkyläntie 50, FI Vantaa VTT 14 ATEX 004X A4 Tel IECEx VTT X Fax [email protected] Piirustusnro / Drawing No. Rev AISI 316L
23
24
25
26
27
28
29
30
31
32 Muutokset sallittu vain sertifikaatin myöntäjän luvalla Changes in the drawing are allowed only by the permission of the authorities who have granted the certificate Piirustus on pätevä dokumentti vain allekirjoitettuna (Tark. ja Hyv.) The drawing is a valid document only with signatures (Chkd. and Appd. ) Kaapeli Cable FEP-Cu-FEP 8x0, C Suojaholkki Protection sleeve AISI 316 PT100 IEC 751 Class A Ilmaraon eriste Air gap insulation Elastomer C Puristus Compression Johtimien eristeet Wire insulation PTFE C Lämmönjohtopasta Heat conductor paste C 10 Pääteholkki C End sleeve C ATEX- ja IECEx-merkintä ATEX- and IECEx-Marking Kaapeli Cable Suojaholkki Protection sleeve Ø6 75 YYYY XXX 2xPt100, Luokka A, 2-, 3- ja 4-johdin, standardin IEC 751 mukaan. Punainen / Red 2x Pt100, Class A, 2-, 3- and 4-wire, acc. to standard IEC 751. Punainen / Red Punainen / Red Punainen / Red Punainen / Red - Maksimi käyttölämpötila C - Maksimi mittausvirta 10 ma - Sähköinen kytkentä sovelluksen mukaisesti hyväksyttyyn laitteeseen tai kytkentäkoteloon kytkentä paikan vaatimusten mukaistesti - Max operating temperature C - Max measuring current 10 ma - Electrical connections to approved unit according to application or to terminal box according to requirements at connecting site Tuote / Product θ θ Valkoinen / White Sininen / Blue Keltainen / Yellow 2XWT-KAAPELI-6/XXX-YYYY/TDT-4J-KLA-EX θ θ Valkoinen / White Sininen / Blue Sininen / Blue Keltainen / Yellow θ θ Valkoinen / White Valkoinen / White Sininen / Blue Sininen / Blue Keltainen / Yellow Keltainen / Yellow Prosessimateriaali(t) / Process Material(s) Piirt. / Drawn Tark. / Chk Hyväks. -pvm. / Aprvd -Date Suhde / Scal. J.Mikkonen R.Ahonen S.Ojanen Info. Koko / Size SKS Automaatio Oy Martinkyläntie 50, FI Vantaa VTT 14 ATEX 004X A4 Tel IECEx VTT X Fax [email protected] Piirustusnro / Drawing No. Rev AISI 316L
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52 SKS Automaatio Oy Martinkyläntie 50, P.O.Box 122, FI Vantaa tel , fax Southern Finland Martinkyläntie 50, P.O.Box 122, FI Vantaa tel , fax Middle Finland Tammelan puistokatu 21 A, FI Tampere tel , fax Western Finland Postikatu 2, FI Turku tel , fax Warehouse address Varastokatu 10, FI Hyvinkää tel , fax SKS Group SKS Automaatio Oy SKS Connecto Oy SKS Control Oy SKS Mechatronics Oy SKS Mekaniikka Oy SKS Toijala Works Oy SKS Tehnika OÜ (Tallinn, Estonia) SKS Group Representative Office (St Petersburg, Russia) SKS China Co. Ltd. (Shanghai, China) SKS Connecto Polska Sp. z o.o. (Grudziadz, Poland) SKS Sweden AB (Lomma, Sweden) SKS Sensors global distributor network Please visit our web site: Publication version Right to changes reserved
Temperature Sensors with ATEX and IECEx approval, Ex d type
Temperature Sensors with ATEX and IECEx approval, Ex d type ATEX / INSTRUMENTS SKS Group SKS is a comprehensive technical supplier having solid expertise and a comprehensive product range to be offered
Technical data sheet TDS0070
Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier
Instructions for Safe Use
Instructions for Safe Use (Certification N:o VTT 08 ATEX 029) Thank you for choosing Slam Trans portable transformer for your job site. Purpose of this manual is to provide you all the necessary safety
Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success
Labkotec SET Labkotec separator alarm system protecting our environment Designed to comply EN 858-1&2 and PPG3 norms Warns of excessive levels of oil, sludge & liquids Prevents pollution incidents Fail-safe
Attachment to GB/FME/ExTR08.006/05 Electrical Apparatus FEP3** ProcessMaster Electromagnetic Flowmeter FEP5** ProcessMaster Electromagnetic Flowmeter FEH3** HygienicMaster Electromagnetic Flowmeter FEH5**
Explosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor
Special Features Wetted parts in stainless steel and PEEK Compact design Precise switching point with no requirement for calibration Process temperature 0... 5 C Measures media with DKvalues >.5 (DK =
Isolating Barriers for our sensors A5S1 in Ex-areas Series D461
D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex
Floodlight Range Installation Guide
SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected
Compact pressure switch Flameproof enclosure Ex d Model PCA
Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring
HARTING Ethernet Cabling 8-poles Overview
Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
ZS25 Screw Clamp Terminal Blocks Feed-through
Technical Datasheet SNK668D0 Catalogue Page SNK678S0 ZS Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to mm² AWG in just mm 0.47 in spacing. SNK68V004 SNK004F0000 D CAD
A good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,
Plug and Socket Devices SolConeX 16 A Series 8570
www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle
Secto Design Oy Kauppalantie 12 02700 Kauniainen Finland tel. +358 9 5050598 fax +358 9 5475 2535 [email protected] www.sectodesign.
Secto Design Oy Kauppalantie 12 02700 Kauniainen Finland tel. +358 9 5050598 fax +358 9 5475 2535 [email protected] www.sectodesign.fi Aspiro 8000 pendant natural birch A freely falling spiral shaped
Terminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
Technical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
FGM 160 ATEX EC type examination certificate
Document number: 75.120.223 Document title: FGM 160 ATEX EC type examination certificate Scope: EN 60079-0, 1, 7, 11, 26 Additional Information (when applicable) F 2015.06.03 New certificate issue Nemko
Micro Motion 3098 Gas Specific Gravity Meter
Product Data Sheet PS-001161, Rev. D April 2013 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.
BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009
d BRÖCKSKES BRÖCKSKES D-VIERSEN D-VIERSEN PV1-F PV1-F 4,0 mm 4,0 2 mm VDE-REG.-Nr. 2 C 8292 10/2009 s - THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control
Thermocoax Isopad Heating Solutions for Hazardous Areas
Thermocoax Isopad Heating Solutions for Hazardous Areas We design and manufacture state of the art customized solutions following latest ATEX and IECEx norms and requirements. Our design capabilities range
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
Terminal Box. Specifications TNCN
Terminal box The /TNCC range comprises many standard sizes of enclosures manufactured in stainless steel 316L for maximum environmental protection. The main body is manufactured from minimum 1,5 mm sheet
CABLE GLANDS AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND ATEX 95 CMP PRODUCTS. Triple Certified
IECEx & ATEX 95 CMP PRODUCTS S AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND Triple Certified Single Solution Three Forms of Protection Ex d / Ex e / Ex nr N O O T H E R M A CONTENTS Leading
Threaded Resistance Thermometers Model TR10-D, Miniature Design
Electrical Temperature Measurement Threaded Resistance Thermometers Model TR10-D, Miniature Design WIKA Data Sheet TE 60.04 Applications Machine building, plant and tank construction Power transmission
IMVIB. Online vibration monitoring for Ariel compressors
IMVIB Online vibration monitoring for Ariel compressors The cost-effective way to add spectral vibration measurement & trending on critical machinery Monitoring vibration trends of your industrial equipment
Operating Instructions
Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4
Linear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:
Oil & Gas / Heavy Industry EX-Proof Stainless Steel Shaft Encoder - Ø 68 mm Shaft - Ø 10 mm to Ø 5/8 inch Resolution up to 10,000 ppr IP 66 (IP 67 option) ATEX certified EX-Proof IECEx certified EX-Proof
Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.
> Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The
Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications
Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
Products Solutions Services. CompEx training From the process safety experts
Products Solutions Services CompEx training From the process safety experts 1 CompEx Training The process safety experts Endress+Hauser is a global leader in measurement instrumentation, services and solutions
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF) Please read these instructions thoroughly before installation and ensure they are passed
Plug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
1788 Linking Device Specifications
Technical Data 1788 Linking Device Specifications Catalog Numbers 1788-EN2DNROM, 1788-EN2DNR, 1788-EN2FFR, 1788-EN2PAR, 1788-CN2DN, 1788-CN2FFR, 1788-CN2PAR, 1788-FBJB4R, 1788-FBJB6 Topic Page 1788-EN2DNR
din din-s 90Ah/plate 155Ah/plate 115Ah/plate 140Ah/plate
traction BATTERIES din 50Ah/plate [h1 = 282, h2 = 305 mm length = b = 198 mm] 2 EPzS 100 L 2 Pg 190 L 100 45 6,8 5,7 3 EPzS 150 L 3 Pg 190 L 150 63 9,6 7,7 4 EPzS 200 L 4 Pg 190 L 200 81 12,4 9,9 5 EPzS
Operating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
Solenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
Chemical resistance Accidental
Industrial flexible cable, insulation and outer sheath in elastomer Description Application TITANEX flexible cable is intended for installations with moving equipment, electric appliances and for building
distributing & controlling system solutions
distributing & controlling system solutions your safety our reality Users > Oil and gas industry production storage transport > Petrochemical industry > Chemical industry > Pharmaceutical industry > Food
Givare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
Cables. Accessories. For Force, Torque and Strain Sensors
Accessories Cables For Force, Torque and Strain Sensors Charge mode, high impedance piezoelectric measurement demands highly insulated coaxial cables and connectors to ensure an insulation resistance greater
ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket
Technical Datasheet SNK636D00 Catalogue Page SNK636S00 ZS-SF-T Screw Clamp Terminal Blocks For x 0 and x fuses - with test socket - Protect your circuit with x and x0 fuse terminal blocks (fuse not supplied
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush
Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB
Air Sensor SAC Ex Manual AQ Elteknik AB ATEX Air Sensor SAC Ex ATEX Certified model Manual version 2.0 Oct 2010 AQ Elteknik AB 2 Table of contents 1. Manufacturer information... 4 Manufacture Declaration
UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.
GE Measurement & Control UNIK 5800/5900 Flameproof/Explosion-Proof Pressure Sensing Platform The 5800 and 5900 are compact and rugged versions of the high performance UNIK 5000 pressure sensing platform
2CMC300001D0003 November 2007. Enclosed switches ATEX
2CMC300001D0003 November 2007 Enclosed switches ATEX Products for use in explosive atmospheres ATEX ABB offers switches for use within dust explosive atmospheres, Category 3 for use in Zone 22. Here is
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
Lockout Specification BW Clip Maintenance-free single gas detector
Lockout Specification BW Clip Maintenance-free single gas detector The gas detector must satisfy the following. Physical Specifications Size (d x w x h ) Physical detector size shall be no larger than
Ammeter / Voltmeter Series 8402, 8403, 8405, 8404
/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,
IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel
Explosion protection Description Flameproof enclosures BARTEC B or EJB series are designed to be installed in industrial plants, where potential hazardous atmospheres occur. These areas are either classified
Ammeter / Voltmeter Series 8402, 8403, 8405, 8404
/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,
System Integration 0 1 2 3 4 5
System Integration 0 1 2 3 4 5 Integration levels Schroff capabilities range from Level 0 (the supply of individual piece parts) to Level 5 (fullsystem integration, providing enclosures with backplanes,
ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors
Installation Instructions P/N MMI-20015054, Rev. AA May 2009 ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors For ATEX-approved sensor installations Note: For hazardous installations
Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
Quality Manual. This Quality Manual complies with the Requirements of ISO 9001:2008 and ISO/IEC 80079-34, Explosive Atmospheres - Edition 1.
This complies with the Requirements of ISO 9001:2008 and ISO/IEC 80079-34, Explosive Atmospheres - Edition 1.0 2011-04 Prepared By: Phyllis Olsen Release Date: 10/28/15 Certificate No: CERT-08776-2006-AQ-HOU-RvA
Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.
egment Protector for Cabinet nstallation Features Assembly 4... 12 outputs Ex ic (FCO or Entity) or non-incendive (Div 2) Advanced fault isolation at the spur egment Protector in Zone 2/Div. 2 nstruments
Product Brochure. Certified Mining Motors
Product Brochure Certified Mining Motors Profile Baldor Electric Company (a member of the ABB group) is a world leader in motors for the mining industry. In the continuous (24/7) operation of underground
1756 ControlLogix Chassis Specifications
Technical Data 1756 ControlLogix Chassis Specifications Catalog Numbers 1756-A4/B, 1756-A4K/B, 1756-A4/C, 1756-A4K/C, 1756-A7/B, 1756-A7K/B, 1756-A7/C, 1756-A7K/C, 1756-A10/B, 1756-A10K/B, 1756-A10/C,
Control- and feedback head for integrated mounting on Robolux valves Type 2036
Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated
ZS6-S Screw Clamp Terminal Blocks Disconnect with blade
Technical Datasheet SNK646D00 Catalogue Page SNK646S00 ZS6-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,
Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)
Features Variants options Glass fiber reinforced polyester (GRP) enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 16 enclosure size options Various terminal
Linear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
Implosive Connectors. for overhead transmission lines
Implosive Connectors Implosive Connectors for overhead transmission lines VP metall is situated in Raufoss Industrial Park, where you find the leading know-how in metallurgy and machining technology in
Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc
Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
TTF300 Field-mount temperature transmitter
Operating Instruction OI/TTF300-EN Rev. F TTF300 Field-mount temperature transmitter Measurement made easy Change from one to two columns Short product description Field-mount temperature transmitter for
ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket
Technical Datasheet SNK64D00 Catalogue Page SNK64S00 ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket - Ease your test operations with the built-in test sockets, - Screwdriver
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
Safety along the complete line: SIRIUS 3SE7 cable-operated switches. sirius COMMANDING & SIGNALING
Safety along the complete line: 3SE7 cable-operated switches sirius COMMANDING & SIGNALING Everything well under control. 3SE7 cable-operated switches With cable-operated switches from our 3SE7 product
L-LAS-TB-CL serie. laser light curtains for inline measuring tasks
L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output
Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,
Accessories Temperature Sensors for Injection Molding Types 6192B, 6193B, 6194B, 6195B Temperature sensors for measuring the contact temperature directly in the cavity at the surface of the solidified
Thermometer in stainless steel with capillary and switch contacts
Design Type Case diameter Thermometer in and switch contacts 7308 = back flange for wall mounting 7312 = front flange for panel mounting 7310 = mounting bracket for wall mounting Dim 100 mm or 160 mm Accuracy
EPHY-MESS GmbH phone: +49 6122 9228-0 Berta-Cramer-Ring 1 fax: +49 6122 9228-99 65205 Wiesbaden email: [email protected] Germany
Temperature sensor PR-SPA-EX-WKF 1. Manufacturer and distributor EPHY-MESS GmbH phone: +49 6122 9228-0 Berta-Cramer-Ring 1 fax: +49 6122 9228-99 65205 Wiesbaden email: [email protected] Germany 2. Applied
Flameproof Audible Signal 115 db (A) Series YA90
Clifford Snell www.stahl.de > Max sound output 115 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > 32 selectable tones meeting international regulations > Light
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
MAGTROL. ZS Series Load Cell. ZS Data Sheet. Features. Description
Data Sheet Series Load Cell Note: Not available in U.S. Features 0.5 t to 5 t (2 kn to 50 kn) Approved for use in calibrated weighing systems High accuracy (C1, C3 or 0.1 and 0.05) Hermetically-sealed
Simpler all over. Simpler all round. 500 MHz. 10 GB ether. fully shielded. Poe+ Cat.6 A. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug
Simpler all over. Simpler all round. No special tools required for field ASSEMBLY Cat.6 A 10 GB ether. 500 MHz fully shielded Poe+ Data Voice MFP8 Cat.6 A Field assembly RJ45 plug Less fuss. More flexibility.
Bypass level indicator With magnetic display Model BNA
Level measurement Bypass level indicator With magnetic display Model BNA WIKA data sheet LM 10.01 Applications Continuous level indication without power supply Indication of the level proportional to height
D.C. Motors. Products and specifications subject to change without notice.
D.C. Motors Order/Technical Support - Tel: (8) 677-5 / FAX: (8) 677-865 / www.crouzet-usa.com / DC Motors Selection guide Gearbox Speed Torque max (Nm).5. Type of Gearbox 8 8 8. Power usable (w) Torque
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
Control and Distribution Boxes made of Stainless Steel Series 8150
www.stahl.de > Circumferential protection channel prevents water entry > Extended temperature range due to high-quality seal s > Optionally with hinges / cam locks or screw-on cover > Hinge versions with
KAM 25-32 A Lighting Busbar System KAP 40-63 A Plug-in Busbar Distribution System
2-32 A Lighting Busbar System 4-63 A Plug-in Busbar Distribution System / E-LINE KX Compact Busbar Distribution System 63...63 A E-LINE KB Compact Busbar Distribution System 8...63 A E-LINE KO Plug-in
Speed sensor MiniCoder GEL 247
Speed sensor MiniCoder GEL 47 Flange assembly Technical information version 08.0 The MiniCoder family from Lenord + Bauer offers spacesaving solutions for the contactless measurement of rotational movements
Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)
Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
S-series Mass Connection Solutions
DeltaV Distributed Control System Product Data Sheet March 2015 S-series Mass Connection Solutions Fast, easy and error-free cabinet wiring Modular design, improves reliability Lowers overall termination
HARTING Ethernet Cabling 4-poles Overview
Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs
Threaded resistance thermometer Model TR10-C, with protection tube
Electrical temperature measurement Threaded resistance thermometer Model TR10-C, with protection tube WIKA data sheet TE 60.03 for further approvals see page 2 Applications Machine building, plant and
LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE
LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE 380/415/690 Volt AC 50/65/80/100 ka 1. Product Guide Low Voltage Motor Control Centre CONTSTRUCTION Continuous "poured in place" gasket
Relative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the
NI 9423. NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module
DATASHEET NI 9423 8-Channel Sinking Digital Input Module 8-channel, 100 µs digital input 24 V logic, sinking digital input Compatible with NI CompactDAQ counters 250 Vrms, CAT II isolation 10-position
Technical Data Sheet. 3DLevelScanner
Changing the market from level to volume Technical Data Sheet APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
Hazardous Locations Training
Hazardous Locations Training If you are involved with projects associated with hazardous locations, which involves the installation or inspection and maintenance of electrical or non-electrical e.g. mechanical;
HARAX circular connector
Show navigation HARAX circular connector Technical characteristics Specifications IEC 60 352-4 IEC 60 9475-2 Approvals HARAX M8-S/M12-S Rated voltage Rated current Diameter of individual strands Conductor
Remote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the