Process Plant for Dairy Products (LE00) (with EDIBON Scada-Net "ESN" System for 30 students working simultaneously)

Size: px
Start display at page:

Download "Process Plant for Dairy Products (LE00) (with EDIBON Scada-Net "ESN" System for 30 students working simultaneously)"

Transcription

1 Issue 3 Process Plant for Dairy Products (LE00) (with EDIBON Scada-Net "ESN" System for 30 students working simultaneously) Index - Process Plant Diagram (Catalogue). - Where to use this Process Plant. - Items included in this Process Plant. - Technical specifications : a) EDIBON Scada Net System technical specifications. b) Items technical specifications. G:\G1-PROYECTOS\G1.6. LABORATORIOS ESPECIALES\PLANTAS PILOTO\INGLES\05MARCH-EDITION3 (actualizandose)\le00-process Plant for Milk\0.- index-le00.doc

2 EDIBON Technical teaching equipment Process Plant for Dairy Products Computer Controlled LE00 MILK Compressed Air Water Vapour Electric energy Cream Skim Pasteurization Powdered Milk Homogenization Dehydration Milk reception and control Filtration Refrigerated Pasteurization Unit UHT Milk UHT Pasteurization Ferments Curd Cheese Cheese Maker Curd Pressing and Molding Salting and Storage Freezed-Dried Packing Freeze Dried Milk Churner Packing Butter Ice-Cream Maker Packing Ice-Cream Homogenization Storing Packing Maturation Homogenization Packing Fermentation Maturation Packing Cheese Required services Pasteurized Milk Yogurt Final Product Specific Process Intermediate Product Initial Product General Process EDIBON Control Interface Box EDIBON PLC Module for Controlling Industrial Processes Software Software EDIBON Software for:: - Computer Control - Data Acquisition - Data Management EDIBON PLC Control Software Computer (PC) SCADA 30 Students post LOCAL NET Worlddidac Quality Charter ISO: Quality Certificate

3 SYSTEM CONFIGURATION ITEMS INCLUDED IN THE SUPPLY: -LE00 Process Plant for Dairy Products complete as - PLC Module for the Control of Industrial- specifications. - Control Interface Box. 7 - Processes with all neccesary accessories. PLC Control Software. - Data Acquisition Board. 8 - Computers and local network included. - Software for: Computer Control+ Data Acquisition 9 - Interconnection elements and all accessories included +Data Management. for normal working operation. -EDIBON SCADA-NET Software Package for 10 - Manuals for: Practices and Exercises, Required Services, classroom control and management. Assembly and Installation, Interface and Control Software, Starting-up, Safety, Maintenance, Calibration.etc. 1 6 EXERCISES TO BE DONE WITH THIS SYSTEM This Process Plant has the target of: Research, Teaching, Production and future businessman platform. It permitsthe following control and process aspects: Analysis of all phases of the product transformation, from reception to packaging. Qualitative evaluation of the finished product as function of the productive operations performed. Experimentation on the efficiency of the different chemical products used for the preservation process. Organization of procedures for continuous quality control of the production operations. TECHNICAL SPECIFICATIONS SUMMARY Execution of procedures for disinfection and sanification of the equipment. Evaluation of technical, legal and administrative aspects concerning food adulteration Manual and computer control operation. Sensors callibration systems. SCADA systems and local net. Anodized aluminium structure and stainless steel metallic elements. All elements needed are chemical resistant. Data Acquisition, Computer Control and Data Management Software. Flexible and open Control Software, compatible with any Windows operating system. PID analog and digital control. Sampling velocity up to data per second. Calibration system for all sensors. Registration of the state of the alarms. Control Interface with front panel process diagram. Real Time PID control and with shield and filtered signals. Sensors with signals of 4-20 ma, 0-5 V, microvolts and Hz, etc, prepared for 0-10 V computer output. 16 analog + 16 digital inlets and 16 digital + 2 analogl outlets. Up to 130 khz sampling velocity. Proportional position and on/off Control, for actuators and control instruments. - Sensors connections in interface with different number of pins, for avoiding student mistakes. PLC box for Industrial Control Processes, with front panel process diagram including PLC Control Software. Manual, semiautomatic and automatic controlled. All system is conected with a local net with 30 computers in which any student can control any block of the process. When the complete process plant is working synchronized,the control is unique and the rest of the computers in the net works as visualization screens. It has been design for a wide range of feed, since 11 to 300 liters, to provide the use for teaching, the production and research. The following units have been designed for optimization of all process involved: Plates Filter (Filtrade): Complementaries techniques specifications available. Refrigerated tank (Refrigeration): Complementaries techniques specifications available Pasteurization unit (Pasteurization): Complementaries techniques specifications available. Homogenization unit (Homogenization): Complementaries techniques specifications available. Yogurt maker (Obtain yogur): Complementaries techniques specifications available. Cheese maket (Obtain curd): Complementaries techniques specifications available. Ice-cream maker (Obtain ice-cream): Complementaries techniques specifications available. Freeze dryer (Freeze dried): Complementaries techniques specifications available. Dehydratation unit (Dehydration): Complementaries techniques specifications available. Press unit (Obtain cheese) : Complementaries techniques specifications available. Butter Maker unit (Obtain butter) : Complementaries techniques specifications available. Cream Separator unit (Skim): Complementaries techniques specifications available. Tank to salting, storage and maturation (Salting and maduration) : Complementaries techniques specifications available. Packing unit (Packing): Complementaries techniques specifications available. UHT unit(uht process) : Complementaries techniques specifications available. Bottling unit (Bottling): Complementaries techniques specifications available. Analysis and quality control laboratory. NOTE: Complete technical specifications and detailed additional information available. * REQUIRED SERVICES -Electrical supply: 220 V/ 50 Hz or 110 V/ 60 Hz. -Water supply. -Compressed air supply. -Vapour supply. DIMENSIONS & WEIGHTS -Dimensions approx. : 14 X 12 X 3 m. -Weight approx. : 3200 Kg. Specifications subject to change without previous notice, due to continuous improvements of the product. EDIBON Technical teaching equipment C/ San José 11-13, ALCORCON (Madrid) SPAIN. Phone: FAX: [email protected] WEB site: Issue: ED01/05 Date: April/2005 DISTRIBUTED BY:

4 Issue 3 Process Plant for Dairy Products (LE00) Where to use this Process Plant Universities and Polytechnics. Technicians Schools. Vocational Schools. Ministry of Labour. Ministry of Education. G:\G1-PROYECTOS\G1.6. LABORATORIOS ESPECIALES\PLANTAS PILOTO\INGLES\05MARCH-EDITION3 (actualizandose)\le00-process Plant for Milk\2.-where to use-le00.doc

5 Process Plant for Dairy Products (LE00) Issue 3 Items included in this Process Plant 1) Teaching, Research and Industrial units (16): Plates Filter (Filtrate) Refrigerated tank (Refrigeration) Pasteurisation unit (Pasteurisation) Homogenisation unit (Homogenisation) Yoghurt maker (Obtain yoghurt) Cheese maker (Obtain curd) Ice-cream maker (Obtain ice-cream) Freeze dryer (Freeze dried) Dehydration unit (dehydration) Press unit (Obtain cheese) Butter Maker unit (Obtain butter) Cream Separator unit (Skim) Tank to salting, storage and maturation (Salting and maturation) Packing unit (Packing) UHT unit (UHT Process) Bottling unit (Bottling). 2) Electronic Interface: Electronic Interface for all units indicated in the point 1 Teaching, Research and Industrial units. 3) 1 Central PLC-MASTER PLC. 4) PLC Unit: PLC Unit for all units indicated in the point 1 Teaching, Research and Industrial units. 5) EDIBON SCADA-NET Software Package (ESN-System) for classroom control and management 6) Software for units: Computer Control + Data Acquisition + Data Management Software for all units indicated in the point 1 Teaching, Research and Industrial units. 7) PLC Software: PLC Software for all units indicated in the point 1 Teaching, Research and Industrial units. 8) Computers System: Central Computer Computers Local Net. 9) Computers Complements: Set of connection cables Projection system for showing in real time any process Normal projector Projection screen Laser Pointer Shelf Accessories for 5 years operation. 10) Manuals: EDIBON Scada-Net Manual Manuals for each Teaching, Research and Industrial Unit. (8 manuals per unit) 11) 1 Week training locally and a trip to Spain are included. G:\G1-PROYECTOS\G1.6. LABORATORIOS ESPECIALES\PLANTAS PILOTO\INGLES\05MARCH-EDITION3 (actualizandose)\le00-process Plant for Milk\3.-items included-le00.doc

6 Issue 3 Technical specifications Process Plant for Dairy Products (LE00) a) EDIBON Scada Net System technical specifications - ESN system introduction: EDIBON SCADA NET (ESN) System reproduces an integrated model plant (CIM model) which defines the various levels of communication: Management design level: orientated towards production management, this level requires the installation of networks, which can handle a large amount of traffic with no restrictions on response time. Local area networks adapted for this level are based on an Ethernet architecture. Factory floor level: factory floors, which are made up of cells, exchange data and can therefore monitor production. At this level the data rate of the network must be high enough to allow to exchange large quantities of data. In this case the factory network is based on a Fipway architecture. Cell level: each device or group of devices are controlled by an overall control system (PLC). Machine or field level: each device includes a group of intelligent sensors, actuators and simple control systems that communicate at this level. Fieldbuses (FIPIO) are used. - ESN system advantages: Main EDIBON SCADA NET SYSTEM innovations: Industrial Ethernet information functionality. Central PLC (PLC NET interface) is used to coordinate large amounts of I/O or data transfers between PLCs. Ethernet network provides extremely fast data collection and control of the plant floor network. This design is very advantageous for anyone who needs real-time access to plant diagnostics (either locally or remote-controlled). Global availability of information. Optimised traffic load allows users to make tuning changes to achieve an optimal performance. Manufacturing data can be easily visualised. Synchronisation of distributed applications. Automation infrastructure is more flexible and adaptable. Any kind of PC and other electronic components can now be integrated into your automation infrastructure. Your plant will remain infinitely expansible and upgradable. - Main possibilities of the system: 30 students simultaneously work with 30 different units. Any student can work simultaneously doing Real Time Control. The teacher can see in his computer what any student is doing in any computer at any time. This system can be linked with any other ESN System (EDIBON Scada Net System). The ESN System is modular, open and expansible. Each unit of the system is open and expansible. Any unit and any system can be visualised simultaneously in n screens by using repro-projection multimedia system. The system is supplied with all necessary accessories, computers etc. COMPLETE SYSTEM FOR FULL RUNNING. Each unit is supplied with 8 manuals. The system has its own manual.

7 Issue 3 1/7 Technical specifications b) Items technical specifications 1) Teaching, Research and Industrial units (16): The technical specifications subject to change without previous notice, due to continuous improvements of the product Plates Filter (Filtrate), with the following technical specifications: - Built in stainless steel AISI 304 with structure in wheels. - Closed bar with stainless steel screw in every models with flying to a good closed to the plates always uniform. - Cardboard 20x20 mm without drill. - Plate of Moplen. - Manometer for pressure control. - Regulated liquid value. - Electropump in stainless steel and motor is built with special voltage. - Diameter connector portpump 20 mm, over order in stainless steel AISI These plates filter have 10 plates, their dimensions are (40x50x57mm). - Weight: 28 Kg. - Production: 600 b/h Refrigerated tank. (Refrigeration), with the following technical specifications: - Tank, covers and lining built in stainless steel. Also all the surfaces in contact with the milk are made of stainless steel, with degree of refined appropriated polishing. - Printed bottom with evaporator that assures the maximum efficiency and minimum comsuption (1,5 kw / 100 L 1,8 kw/100 L). - Effective isolation by means of injected polyurethane to increase, increments of temperature in the milk. - Inclination of the bottom to achieve a quick casting. - Started anti-air of the milk to archive the volume measurement, in the tank. - Automatic operation of the cooling group and the stire to assure a good homogenisation of the milk. - Coolant. - Adjustable legs. - Volume measurement of the milk. - Compresated hinge. - Frame of stainless steel. - Single phase 220 V Pasteurisation unit. (Pasteurisation), with the following technical specifications: - Anodised aluminium structure and stainless steel metallic elements. - Data Acquisition, Computer Control and Data Management Software. Flexible and open Control Software, compatible with any Windows operating system. PID analog and digital control. Sampling velocity up to data per second. Calibration system for all sensors. Registration of the state of the alarms. - Control Interface with front panel process diagram. Real Time PID control and with shield and filtered signals. Sensors with signals of 4-20 ma, 0-5 V, microvolts and Hz, etc, prepared for 0-10 V computer output. 16 analog + 16 digital inlets and 16 digital + 2 analog outlets. Up to 130 khz sampling velocity. Proportional position and on/off Control, for actuators and control instruments. - Sensors connections in interface with different number of pins, for avoiding student mistakes. - PLC box for Industrial Control Processes, with front panel process diagram including PLC Control Software. - Technical Data: Pasteurisation Capacity: 250 l/h. Flow of water in the exchange section: 750 l/h. Thermal Cycle: ºC. Time of retention: 20 seconds to 250 l/s of milk. Temperature of the water in the heating section: 79 ºC. Badges in the regeneration section and in the pasteurisation section. Temperature Sensors. Etc Homogeneization unit. (Homogenization), with the following technical specifications:

8 Issue 3 2/7 - Maximum capacity: 11 l/h. - Maximum pressure: 2000 bar. - Every part are built in stainless steel, this structure is resistance to the acids. - This model has a sanitary design, it permits the water or chemicals products recirculate in the washing process. - Suction valve and seats of the valves in tungsten carbure. - Homogenised simple phase with seat in tungsten carbure. - Digital manometer to indicate the homogenisation pressure, with overpressure meter. - Ceramic piston. Packing machine in PVDF/EPDM. - Pistons refrigeration system and packing machine for water recirculate. - Supply feed tank. - Recirculate tubes. - Electrical engine of 3.0 kw, x80, 460 V/50 Hz, internal cabling and running-stopping switch. - This equipment is included a packing to equipment working, manual services Yoghurt maker (Obtain yoghurt), with the following technical specifications: - Computer Control, Data Acquisition and Data Management Software. Flexible and open Control Software, compatible with any Windows operating system. PID analog and digital control. Sampling velocity up to data per second. Calibration system for all sensors. Registration of the state of the alarms. - Control Interface with front panel process diagram. Real Time PID control and with shield and filtered signals. Sensors with signals of 4-20 ma, 0-5 V, microvolts and Hz, etc, prepared for 0-10 V computer output. 16 analog + 16 digital inlets and 16 digital + 2 analog outlets. Up to 130 khz sampling velocity. Proportional position and on/off Control, for actuators and control instruments. - Sensors connections in interface with different number of pins, for avoiding student mistakes. - PLC box for Industrial Control Processes, with front panel process diagram including PLC Control Software. - The unit contains the following elements: Unit with enameled chassis and with reinforced isolation. Stainless steel AISI 304 main body. 3000KW resistance. 2 Temperature Sensors, type K. ph Sensor with electrolyte solution. Fan. 250ml vessel. 8 mobile grills. Safety switch (alarm open door). Temperature digital controller with sensor. Manual or Computer Control switch. Unit on/off switch. Unit on/off indicator Led. Safety indicator Led (alarm open door). Resistance on/off indicator Led. Diagram in the front panel. Sensors connectors and resistance and fan connectors to interface (computer control).etc Cheese maker (Obtain curd), with the following technical specifications: - Computer Control, Data Acquisition and Data Management Software. Flexible and open Control Software, compatible with any Windows operating system. PID analog and digital control. Sampling velocity up to data per second. Calibration system for all sensors. Registration of the state of the alarms. - Control Interface with front panel process diagram. Real Time PID control and with shield and filtered signals. Sensors with signals of 4-20 ma, 0-5 V, microvolts and Hz, etc, prepared for 0-10 V computer output. 16 analog + 16 digital inlets and 16 digital + 2 analog outlets. Up to 130 khz sampling velocity. Proportional position and on/off Control, for actuators and control instruments. - Sensors connections in interface with different number of pins, for avoiding student mistakes. - PLC box for Industrial Control Processes, with front panel process diagram including PLC Control Software. - The unit contains the following elements: AISI 304 stainless steel tank (45 litres), with water jacket. ph Sensor. Optic Level Sensor. Temperature Sensor, pt 100 type. Electric resistance with IP66 protection, 6KW. Whey outlet valve. Water outlet valve. Water inlet valve. Drain pipe and vapour outlet. Sealed box IP66 containing: digital temperature controller, manual or computer control switch, electric resistance on/off switch, resistance condition indicator Led, on/off unit switch, water level indicator Led, and diagram in the front panel. Required time for the process 45min. Work temperature between 70-90ºC. Etc Ice-cream maker. (Obtain ice-cream) Freeze dryer. (Freeze dried), with the following technical specifications: - Built in stainless steel. - Number of tray: 4 to 5.

9 Issue 3 3/7 - Surface of work in every tray: mm. - Total surface of work: 1.8 m 2. - Capacity of condenser: 18 Kg. - Energy required: 20 Amps; one-phase, 50 Hz. - Open door is built in acrylic glass. - Range of temperature in plate: -25 to +60. Celsius grades. - Heat power:2 kw. - Power of equipment: 800 Kg. - Condenser material: Stainless steel. - Heat transfer medium: Glicol. - Liquid of condenser: Water Dehydration unit (dehydratation) Press unit. (Obtain cheese) Butter Maker unit (Obtain butter), with the following technical specifications: - Anodised aluminium structure and stainless steel metallic elements. - Data Acquisition, Computer Control and Data Management Software. Flexible and open Control Software, compatible with any Windows operating system. PID analog and digital control. Sampling velocity up to data per second. Calibration system for all sensors. Registration of the state of the alarms. - Control Interface with front panel process diagram. Real Time PID control and with shield and filtered signals. Sensors with signals of 4-20 ma, 0-5 V, microvolts and Hz, etc, prepared for 0-10 V computer output. 16 analog + 16 digital inlets and 16 digital + 2 analog outlets. Up to 130 khz sampling velocity. Proportional position and on/off Control, for actuators and control instruments. - Sensors connections in interface with different number of pins, for avoiding student mistakes. - PLC box for Industrial Control Processes, with front panel process diagram including PLC Control Software. - The unit contains the following elements: Tank for Cream. Lactic Thermometer. Nylon Sieve. Plastic Gloves. A Muslin Roll. Etc. Approximately 0.5 l of cream could be obtained from 4 l of milk, depending on the grease contained in the milk. And approximately 0.5 kg of butter could be obtained from 1.5 l of cream Cream Separator unit (Skim), with the following technical specifications: - Anodised aluminium structure and stainless steel metallic elements. - Data Acquisition, Computer Control and Data Management Software. Flexible and open Control Software, compatible with any Windows operating system. PID analog and digital control. Sampling velocity up to data per second. Calibration system for all sensors. Registration of the state of the alarms. - Control Interface with front panel process diagram. Real Time PID control and with shield and filtered signals. Sensors with signals of 4-20 ma, 0-5 V, microvolts and Hz, etc, prepared for 0-10 V computer output. 16 analog + 16 digital inlets and 16 digital + 2 analog outlets. Up to 130 khz sampling velocity. Proportional position and on/off Control, for actuators and control instruments. - Sensors connections in interface with different number of pins, for avoiding student mistakes. - PLC box for Industrial Control Processes, with front panel process diagram including PLC Control Software. - The unit contains the following elements: Separation Bowl. Motor. Velocity regulator. Digital indicator. Milk Reservoir and Separation Bowl. Feed Reservoir. Etc Tank to salting, storage and maturation (Salting and maduration) Packing unit (packing), with the following technical specifications: - Dose time programming. - With possibility or creating a small aspiration after each dose, to avoid leak ages. - Possible to adjust the doses directly on the front keyboard. - Possible to work in continuous. - Possible to work in automatic way with regulation of the time of stop among almost dose.cadence settles down. - Possible to work in manual, by means of switch off button. - Possible to program certain quantity of dose with systematic counts of the doses.

10 Issue 3 4/7 - Dose accountant. - Capability of 10 memories to establish the parameters of the doses or memorisation of the regulations of the doser for 10 products and different volumes. - Visualisation of the dosage memories. - Possible to dose liquids, and mash products of different densities, auxiliary coupling and discupling elements as the product, needs (Yoghurt, butter, sauces, pates, juices, etc..) UHT unit (UHT Process), with the following technical specifications: - Anodised aluminium structure and stainless steel metallic elements. - Data Acquisition, Computer Control and Data Management Software. Flexible and open Control Software, compatible with any Windows operating system. PID analog and digital control. Sampling velocity up to data per second. Calibration system for all sensors. Registration of the state of the alarms. - Control Interface with front panel process diagram. Real Time PID control and with shield and filtered signals. Sensors with signals of 4-20 ma, 0-5 V, microvolts and Hz, etc, prepared for 0-10 V computer output. 16 analog + 16 digital inlets and 16 digital + 2 analog outlets. Up to 130 khz sampling velocity. Proportional position and on/off Control, for actuators and control instruments. - Sensors connections in interface with different number of pins, for avoiding student mistakes. - PLC box for Industrial Control Processes, with front panel process diagram including PLC Control Software. - The unit contains the following elements: Feed tanks (2 litres capacity). Steam heating vessel with atomiser spray head. Vacuum vessel with vapour/liquid separator. These process vessels are mounted in series. Vacuum pump with variable vacuum. Control valves. Pressure Sensors. Temperature Sensors. Etc Bottling unit (bottling), with the following technical specifications: - Built in stainless steel AISI Skeleton dismantled and articulates mouthpieces to easier of introduction and extraction of the bottles. - Level meter to electrovalves. - Model with pump in stainless steel, there a version without pump. - Regulated vat to collect of drops. - Unloading area to empty the machine. - Production: 300 l/h - Dimensions: 90x60x170 - Weight: 115 Kg. 2) Electronic Interface: Electronic Interface for all units indicated in the point 1 "Teaching, Research and Industrial units", with the following technical specifications: - Interface of 500x300x350 mm. with the process diagram in the frontal and with the same distribution that the different elements located in the equipment, for an easy understanding by the student. - All sensors, with its respective signals (4-20 ma, 0-5 V, microvolts, Hz., etc.), are properly manipulated for 0-10 V. computer output. - The connectors of the sensors to the interface have different pines numbers (from 2 to 16), to avoid connection errors. Single cable between the interface and the computer. - The equipment control elements are permanently computer controlled, without necessity of changes or connections during the whole test process procedure. - Real time PID control, with flexibility of modifications, from the computer keyboard, of the PID parameters, at any moment of the process. - Shield and filtered signals to avoid external interferences. - All the electrical units (pumps, compressors, resistances, etc.) are computer controlled, for on/off, speed regulation and power. - Conventional mechanical and electrical protection systems, and also, computer protection and in a simultaneous way. - Inputs: 16 analogical and 16 digital. - Outputs: 16 digital and 2 analogical, adjustable from 0-10 volts. - Sampling velocity up to 130 khz. - Proportional position control with feed back system, Total PID control as much in velocity as in

11 Issue 3 5/7 position (proportional band and proportional error). On/off control for actuators and other control types. - 5 Cables (minimum) with sensors of pressure, level, temperature, etc. - Power Supply. - 5 Signal Conditioning Cards. - 3 Connection Cables (minimum) for PC to interface and Interface to main supply. 3) 1 Central PLC-MASTER PLC. - Electric PLC Premium TSX - P5736 with Ethernet TSX ETY 410 module and PCMCIA card enables to connect to fipway network: 10/100 Mbps with autosensing (FSTP RJ45). Support of legacy protocols on TCP/IP-UNI-TE-MODBUS. I/O Scanner service - The Central PLC-Master PLC is part of an integrated model plant that uses X-WAY networks and it can be perfectly integrated into the CIM model. - Several networks operating on different levels and on sites which may reach a considerable size, can only work together and provide total communications if the networks are connected together in hierarchical (multi-network) architecture. - The Central PLC-Master PLC provides the connection between two network types, Ethernet and Fipway, by a common PLC (network node) in a bridge type architecture where the PLC routes messages from one network to another. - The elements are: Ethernet connection. Provides the connection to the Ethernet network that is the communication to the PCs. Fipway connection. Provides the connection to the fipway network, that is the communication to the PLCs. An end of line is connected to one of them, because the PLC are in cascada architecture. Unitelway connection. This type of connection is necessary to charge the programme and PLC, including the Central PLC-Master PLC, have a unitelway connection. Power supply. 4) PLC Unit: PLC Unit for all units indicated in the point 1 "Teaching, Research and Industrial units", with the following technical specifications: - Electric PLC Micro TSX 3721 with PCMCIA card. - Power supply V (AC). - RAM memory (20 Kword+memory data) + Flash EPROM (15 Kword). - 8 integrated analogic input (0-10V). - 1 integrated analogic output (0-10V) digital input/output module (24V). 5) EDIBON SCADA-NET Software Package (ESN-System) for classroom control and management. - The ESN-Software (EDIBON SCADA-NET System) is an acquisition and control software developed entirely by technicians of EDIBON. In its development, we have been taken into account the experience accumulated in more than 20 years developing teaching equipment. - The system is prepared to communicate with Electric PLC's, through OFS Software. OFS (OPC Factory Server) is a multi-plc data Server that uses the OPC (OLE for Process Control) standard which allows ESN-Software (data processing application) to access the control system variables in Electric PLCs (Micro and Premium PLC models). - In this system, there are different configuration levels that allow the professor to design in the fair measure the execution of the different practical exercises. The basic level is prepared for the capture and storage of data that the student will process and will work with later. The medium level allows the student the use of the graphic tools that allows, in real time, the visualisation of the data experiment. Finally, it has an advanced level specially designed for the capture configuration, the sensors device calibration and to change the PLCs parameters. This system is subject to a key provided by EDIBON. 6) Software for units:

12 Issue 3 6/7 Computer Control + Data Acquisition + Data Management Software for all units indicated in the point 1 "Teaching, Research and Industrial units", with the following Technical Specifications: - Compatible with any Windows operating system. Graphic and intuitive simulation of the process in screen. Equivalent distribution of the elements to the real process. Registration and visualisation of all the process variables in an automatic way. - Flexible Control Software, developed with actual windows graphic systems, acting on all process parameters. Data acquisition and also with PID analogical and digital control and other control types. Menu for PID and the set point selection required in the whole work range. It provides the management, processing, comparison and storage of all the data, with a sampling velocity up to data per second. Nested loops control system. - Calibration system, for the student's use of all the sensors that work in the process. - It allows the registration of the state of the alarms and the graphic representation in real time. Comparative analysis of the obtained data, after to the process and modification of the conditions, during the process. - Open software, allowing to the teacher to modify texts, instructions, etc. Teacher's and student s passwords to facilitate the teacher's control on the student, and that it allows the access at different work levels. - This software is prepared to be adapted to this particular process, with capacity for doing all the exercises indicated in the Fluid Friction in Pipes Unit. 7) PLC Software PLC Software for all units indicated in the point 1 "Teaching, Research and Industrial units" for doing all the exercises and practical possibilities indicated in units catalogues and technical information of this laboratory. 8) Computers System Central Computer, with the following basic technical specifications: - Intel Pentium IV processor 2.8 GHz MB RAM DDR GB HD. - CD R/W. - Ethernet card. - 17" Screen. - O.S. Windows Computers, with the following basic technical specifications: - Intel Pentium IV processor 2.6 GHz MB RAM DDR GB HD. - CD R/W. - Ethernet card. - 15" Screen. - O.S. Windows Local Net: - Couple braided cable, gage AWG, 4 leads. - Wire with RJ-45 connectors. - Switch. - Maximum segment length: 100 meters. - Maximum attenuation: -11.5dB. - Characteristics impedance: 85 to 111 ohm. - Velocity: 10 Mbips per second. - Base-band transmission - Propagation delay: 5.7 ns/ km. - Maximum delay by segment: 1000 ns. - Star topology. 9) Computers Complements.

13 Issue 3 7/ Set of connection cables Projection system for showing in real time any process Normal projector Projection screen Laser pointer Shelf Accessories for 5 years operation. 10) Manuals EDIBON Scada-Net Manual Manuals for each Teaching, Research and Industrial Unit. (8 manuals) - Required services manual. - Assembly and installation manual. - Interface and software/control console manual - Set in operation manual. - Safety norms manual. - Practices manual. - Maintenance manual. - Calibration manual. 11) 1 Week training locally and a trip to Spain are included.

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC Technical Teaching Equipment Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC Teaching Technique used EDIBON SCADA System 2 Control Interface Box 5 Cables and Accessories 6 Manuals 3

More information

Computer Controlled Capacity Control Methods in Refrigeration, with SCADA and PID Control THARA2C/1

Computer Controlled Capacity Control Methods in Refrigeration, with SCADA and PID Control THARA2C/1 Technical Teaching Equipment Computer Controlled Capacity Control Methods in Refrigeration, with SCADA and PID Control THARA2C/1 EDIBON SCADA System and PID CONTROL included Teaching Technique used 5 6

More information

Computer Controlled Automobile Air Conditioning Trainer, with SCADA TAAUC

Computer Controlled Automobile Air Conditioning Trainer, with SCADA TAAUC Technical Teaching Equipment Computer Controlled Automobile Air Conditioning Trainer, with SCADA TAAUC EDIBON SCADA System Teaching Technique used 1 Unit: TAAUC. Automobile Air Conditioning Trainer 5 6

More information

Computer Controlled Nozzle Performance Test Unit, with SCADA TFTC

Computer Controlled Nozzle Performance Test Unit, with SCADA TFTC Technical Teaching Equipment Computer Controlled Nozzle Performance Test Unit, with SCADA TFTC EDIBON SCADA System Teaching Technique used 1 Unit: TFTC. Nozzle Performance Test Unit 5 6 2 Control Interface

More information

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE Technical Teaching Equipment Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE EDIBON SCADA System Teaching Technique used 4 5 2 Data Acquisition Board Cables and

More information

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Visions become real. Temperature control and cooling systems. The innovative and reliable solution Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature

More information

OT 40L / 90L. Laboratory Steam Sterilizers

OT 40L / 90L. Laboratory Steam Sterilizers OT 40L / 90L Laboratory Steam Sterilizers OT 40L / 90L LABORATORY STEAM STERILIZERS OT 40L / OT 90L laboratory steam sterilizers are specially designed for the steam sterilization of liquid and culture

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric energy and heat -

ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric energy and heat - Doc. : 08C00031_e Date : 10.02.2009 Page : 1 / 9 ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric - (Preliminary) Doc. : 08C00031_e

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

Computer Controlled Axial Fan Teaching Trainer, with SCADA HVAC

Computer Controlled Axial Fan Teaching Trainer, with SCADA HVAC Technical Teaching Equipment Computer Controlled Axial Fan Teaching Trainer, with SCADA HVAC Teaching Technique used EDIBON SCADA System 2 Control Interface Box 5 Cables and Accessories 6 Manuals 3 Data

More information

Computer Controlled Photovoltaic Solar Energy Unit, with SCADA EESFC

Computer Controlled Photovoltaic Solar Energy Unit, with SCADA EESFC Technical Teaching Equipment Computer Controlled Photovoltaic Solar Energy Unit, with SCADA EESFC EDIBON SCADA System Teaching Technique used 2 Control Interface Box 5 Cables and Accessories 6 Manuals

More information

Computer Controlled Stirling Motor, with SCADA TMSC

Computer Controlled Stirling Motor, with SCADA TMSC Technical Teaching Equipment Computer Controlled Stirling Motor, with SCADA TMSC EDIBON SCADA System Teaching Technique used 2 Control Interface Box 5 Cables and Accessories 6 Manuals 3 4 Data Acquisition

More information

LABOKLAV. Autoclaves Made in Germany. www.shp-steriltechnik.de

LABOKLAV. Autoclaves Made in Germany. www.shp-steriltechnik.de LABOKLAV Autoclaves Made in Germany www.shp-steriltechnik.de 2 LABOKLAV STEAM STERILIZERS Steam sterilization is the sterilization method with the widest range of applications efficient, safe, reproducible

More information

Material test chamber with mechanical convection

Material test chamber with mechanical convection FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Power consumption (kw)

Power consumption (kw) OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components

More information

Photovoltaic Solar Energy Unit EESFB

Photovoltaic Solar Energy Unit EESFB Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality

More information

BB-18 Black Body High Vacuum System Technical Description

BB-18 Black Body High Vacuum System Technical Description BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The

More information

Kompressoren. Adsorption Dryer AD

Kompressoren. Adsorption Dryer AD Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated

More information

CRAC Precision climate control units for data centres

CRAC Precision climate control units for data centres CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have

More information

HEINRICH FRINGS INFORMATION

HEINRICH FRINGS INFORMATION THE MODERN PRODUCTION OF ALCOHOL VINEGAR FRINGS offers a number of fermentation processes for the production of just that individual product which suits your market needs. The main difference between these

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing

More information

Electric Flow Boiler

Electric Flow Boiler Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler

More information

Cooking at the Speed of light!

Cooking at the Speed of light! Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide

More information

Audio and Video Door Entry System LIELBA - AD14

Audio and Video Door Entry System LIELBA - AD14 Technical Teaching Equipment Audio and Video Door Entry System LIELBA - AD14 Products Products range Units 4.-Electricity ELEMENTS ALLOCATION ALI02 POR06 POR05 and POR07 POR04 POR08 Modules: ALI02= Main

More information

FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS

FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS The key difference between a small vertical or bench-top sterilizer and industrial sterilizer is performance. Small saturated-steam sterilizers with vertical or horizontal chambers were devised many years

More information

Computer Controlled Process Control System (with electronic control valve), with SCADA and PID Control UCP

Computer Controlled Process Control System (with electronic control valve), with SCADA and PID Control UCP Technical Teaching Equipment led System (with electronic control valve), with SCADA and PID UCP EDIBON SCADA System and PID CONTROL included Teaching Technique used 1 UCP-UB. Base Unit 2 Interface Box

More information

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines On customer request it is possible to supply: Benches for PCB Oven for PCB Chemicals

More information

EDIBON SCADA-NET System (ESN) for Chemical Engineering ESN-CHEMICAL ENGINEERING

EDIBON SCADA-NET System (ESN) for Chemical Engineering ESN-CHEMICAL ENGINEERING Technical Equipment EDIBON SCADA-NET System (ESN) for Chemical Engineering ESN-CHEMICAL ENGINEERING ESN. SCADA-NET TEACHING SYSTEM New concept of Laboratories SCADA-NE T Teacher computer OPEN CONTROL +

More information

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service: www.novairmedical.com

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service: www.novairmedical.com MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM Designed for centralized medical air production in hospitals and clinics, NOVAIR medical air stations ensure the continuous supply of the medical gas

More information

FVA/A1 saturated-steam sterilizer

FVA/A1 saturated-steam sterilizer FVA/A1 where technology innovation and design come together FVA/A1 saturated-steam sterilizer www.fedegariautoklaven.ch Fedegari's new FVA/A1 series of automatic vertical sterilizers has been expressly

More information

Morgue refrigeration unit

Morgue refrigeration unit Morgue refrigeration unit The Morgue refrigeration units are made of sturdy, self-supporting walls, floor and ceiling elements. They are delivered in separate components and are to be assembled on site

More information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

Titan Makina Ltd. Şti. 1160. Sok. No: 9 Ostim 06370 Ankara Tel: + 90 312 354 9977 Fax: + 90 312 385 5611 Web: www.titanltd.com.

Titan Makina Ltd. Şti. 1160. Sok. No: 9 Ostim 06370 Ankara Tel: + 90 312 354 9977 Fax: + 90 312 385 5611 Web: www.titanltd.com. IS26 Concrete Spraying Machine IS26 Concrete Spraying Machine TECHNICAL SPECIFICATIONS Manipulator Max. vertical spraying reach : Max. horizontal spraying reach : Working lights : Spraying Head Rotation

More information

Climate chamber with illumination

Climate chamber with illumination KBWF series (E5.2) Climate chambers with illumination Climate chamber with illumination The BINDER climate chamber with illumination of the KBW series achieves homogeneous light distribution with its natural

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

BSL3 and BSL4 Autoclaves. Laboratory Line

BSL3 and BSL4 Autoclaves. Laboratory Line BSL3 and BSL4 Autoclaves Laboratory Line BSL3 and BSL4 Autoclaves In today s society the need for safe bio-containment systems is increasingly important. This is especially true in the sterilization process

More information

Remote Control Station Via Telephone

Remote Control Station Via Telephone Technical Teaching Equipment Remote Control Station Via Telephone LIELBA - AD40 Products Products range Units 4.-Electricity ELEMENTS ALLOCATION ALI02 Modules: ALI02=Main Power Supply. CTR01=Basic Control

More information

Programmable Logic Controller PLC

Programmable Logic Controller PLC Programmable Logic Controller PLC UPCO ICAI Departamento de Electrónica y Automática 1 PLC Definition PLC is a user friendly, microprocessor based, specialized computer that carries out control functions

More information

Designed for multi-injector endurance testing, the

Designed for multi-injector endurance testing, the Designed for multi-injector endurance testing, the ETB Test Bench can optionally provide shot-to-shot mass measurement. The injectors are precisely subject to variable controls and hydraulic pressures

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

LyoBeta. R+D Freeze-Dryers

LyoBeta. R+D Freeze-Dryers LyoBeta R+D Freeze-Dryers LyoBeta series A Responsible Choice New demands in R+D centers are related to scale-up feasibility and quality of procedures and research methods. FDA investigators consider that

More information

ORGANIC SAMPLE PREPARATION

ORGANIC SAMPLE PREPARATION ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of

More information

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None 1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements

More information

Adsorption air dryers ADS 1 215

Adsorption air dryers ADS 1 215 Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that

More information

Customer: Cardiff Hospital NHS (United Kingdom) Machine:

Customer: Cardiff Hospital NHS (United Kingdom) Machine: Customer: Cardiff Hospital NHS (United Kingdom) Machine: Bench for leak test Model: Easy TS Page 1 of 7 Date: 6 th March 2012 1. Introduction. Easy TS is a compact and reliable table top bench designed

More information

SERVICE MANUAL REFRIGERATION

SERVICE MANUAL REFRIGERATION SERVICE MANUAL REFRIGERATION ELECTROLUX HOME PRODUCTS S.p.A. Publication no. Spares Operations Italy 599 36 16-90 Corso Lino Zanussi, 30 031117 I - 33080 PORCIA / PN (ITALY) ITZ/SERVICE/AA Fax +39 0434

More information

NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER

NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER Understanding what a PAC is starts from the understanding of PLC. A PLC is a Programmable Logic while

More information

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009 Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal

More information

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK CL - CH - CK Direct driven solution for industry Proven technology, solid construction The CL - CH - CK units are directly driven air-cooled, single

More information

EcoCWave. The all-round talent for aqueous part cleaning. www.durr.com

EcoCWave. The all-round talent for aqueous part cleaning. www.durr.com EcoCWave The all-round talent for aqueous part cleaning www.durr.com Part cleaning as a value-adding value-adding process process Increasing demands on cleanliness in component manufacturing impose a need

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection

More information

System integration oriented data center. planning. In terms of ATEN's eco Sensors DCIM solution

System integration oriented data center. planning. In terms of ATEN's eco Sensors DCIM solution System integration oriented data center planning In terms of ATEN's eco Sensors DCIM solution 1. Introduction The reliability of an enterprise data center servicing either external or internal clients

More information

A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing.

A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing. Appro HyperBlade A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing. Appro HyperBlade clusters are flexible, modular scalable offering a high-density

More information

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp

More information

On-line Machine Condition Monitoring [The CMS System]

On-line Machine Condition Monitoring [The CMS System] On-line Machine Condition Monitoring [The CMS System] Strategic monitoring control your costs Avoid unplanned downtime Monitor your plant stoppers Early warning maintains profit Efficient and profitable

More information

Vibration Monitoring System Adash 3600

Vibration Monitoring System Adash 3600 " User's guide Application: Vibration Monitoring System Adash 3600! Vibration diagnostics, monitoring and protective on-line system! On-line vibration monitoring system of engines, fans, pumps, gearboxes,

More information

GenStore Archive Cabinet

GenStore Archive Cabinet GenStore Archive Cabinet Setup and Maintenance Manual Version A April 2014 Two GenStore Archives shown mounted on optional table stand. 2 Contents Getting Started... 4 Using this Manual...4 Safety Precautions...4

More information

SWISS MADE. Series 320 XB MASTER. Analytical. Precision

SWISS MADE. Series 320 XB MASTER. Analytical. Precision SWISS MADE MASTER Series Analytical Precision MASTER Series The Precisa 320 high performance series combines precision and quality, and offers the highest metrological performance and advanced integrated

More information

Silicone oil is as the medium and the drying effect is uniform. The Temperature error is less than or equal 1.

Silicone oil is as the medium and the drying effect is uniform. The Temperature error is less than or equal 1. Characteristic: The process of pre-freezing and drying finishes in situ. The freeze dryer is equipped with observation windows and the drying process is intuitive. Silicone oil is as the medium and the

More information

Conlift1, Conlift2, Conlift2 ph+

Conlift1, Conlift2, Conlift2 ph+ GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications

More information

Partnership. Medical Waste Autoclaves. Medical Waste Autoclaves

Partnership. Medical Waste Autoclaves. Medical Waste Autoclaves Partnership Medical Waste Autoclaves Medical Waste Autoclaves Safe, Cost-Effective, Medical Waste Sterilization Keep your environment safe from Medical Waste with high performance Tuttnauer Medical Waste

More information

Heating oven with mechanical convection

Heating oven with mechanical convection FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous

More information

Laboratory & Scientific Line. Bulk Steam Sterilizers. Since

Laboratory & Scientific Line. Bulk Steam Sterilizers. Since Laboratory & Scientific Line Bulk Steam Sterilizers Since 1925 Bulk Steam Sterilizers for Laboratory & Scientific Applications The Tuttnauer line of bulk autoclaves are designed to handle the most critical

More information

RPV - RP - RA air handling units

RPV - RP - RA air handling units APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

Telephony Systems Trainer CODITEL

Telephony Systems Trainer CODITEL Technical Teaching Equipment Telephony Systems Trainer CODITEL Always included in the supply: Teaching Technique used EDIBON Computer Control System 2 Computer Control Software Computer (not included in

More information

AutoLog ControlMan. Remote Monitoring & Controlling Service

AutoLog ControlMan. Remote Monitoring & Controlling Service AutoLog 1 AutoLog ControlMan Remote Monitoring & Controlling Service Web browser based HMI / SCADA interface Server is hosted by Internet server hosting company Control units communicate wirelessly via

More information

data sheet DONATELLO Rev. I emiss - 25/10/2013 52PRO03 code Automatic tissue processor DONATELLO

data sheet DONATELLO Rev. I emiss - 25/10/2013 52PRO03 code Automatic tissue processor DONATELLO Rev. I emiss - /0/0 DONATELLO Automatic floor closed cycle processor for histological specimens Automatic tissue processor DONATELLO code PRO0 General characteristics DONATELLO is a closed cycle processor

More information

Intelligent Vibration Monitoring

Intelligent Vibration Monitoring Diagnostic Systems Condition Based Monitoring Diagnostic Systems Condition Based Monitoring Intelligent Vibration Monitoring efector Octavis for real-time vibration monitoring Solutions for Predictive

More information

Atlas Copco Stationary air compressors

Atlas Copco Stationary air compressors Atlas Copco Stationary air compressors Oil-free and oil lubricated piston compressor 2.2 - kw / 3-7.5 hp QUALITY COMPRESSORS DESIGNED SPECIFICALLY FOR THE SNOW MAKING INDUSTRY Atlas Copco's L-range of

More information

Turbine Flow Sensor Series VTR

Turbine Flow Sensor Series VTR Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

Programming Logic controllers

Programming Logic controllers Programming Logic controllers Programmable Logic Controller (PLC) is a microprocessor based system that uses programmable memory to store instructions and implement functions such as logic, sequencing,

More information

HYDRAULICS. H91.8D/C - Computerized Open Surface Tilting Flow Channel - 10, 12.5, 15 and 20 m long

HYDRAULICS. H91.8D/C - Computerized Open Surface Tilting Flow Channel - 10, 12.5, 15 and 20 m long HYDRAULICS H91.8D/C - Computerized Open Surface Tilting Flow Channel - 10, 12.5, 15 and 20 m long 1. General The series of channels H91.8D has been designed by Didacta Italia to study the hydrodynamic

More information

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while

More information

Terms of Reference. to INQUIRY No: 04/2014

Terms of Reference. to INQUIRY No: 04/2014 Nowa Sól, 26.05.2014. Terms of Reference to INQUIRY No: 04/2014 For the investment project " EGG WHITE PROTEIN MEMBRANE UNTRAFILTRATION DEVICE in the project titled: "Getting new products by isolation

More information

TEMPERATURE MEASURING GALVANIC SEPARATORS CONVERTORS, PRESSURE MEASURING

TEMPERATURE MEASURING GALVANIC SEPARATORS CONVERTORS, PRESSURE MEASURING DELIVERY PROGRAMME TEMPERATURE MEASURING - Resistance temperature sensors into a reservoir, - with a reservoir, with protection tube, with cable - Resistance temperature sensors Ex to zones 2, 1 - - and

More information

Backflush filter R8-30W

Backflush filter R8-30W Backflush filter R8-30W With internal pressure segment cleaning, rated pressure to 40 bar (580 psi) Connection sizes: DN 200 to DN 500, welded design 1. Features Powerful, fully automatic filtration _

More information

Medical Waste Autoclaves. Medical Waste Autoclaves

Medical Waste Autoclaves. Medical Waste Autoclaves Medical Waste Autoclaves Medical Waste Autoclaves Safe, Cost-Effective, Medical Waste Sterilization Treat Medical Waste with high performance Tuttnauer Medical Waste autoclave systems designed for small,

More information

Partner for automation Water technology

Partner for automation Water technology Partner for automation Water technology Your objective: Economy in plant engineering and plant lifecycle management Energy prices today are high and rising even further, forcing you as municipal or industrial

More information

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power: PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV

More information

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC HOJA TÉCNICA 1400H101 Edición 01 (02 de 08) www.ako.es GENERAL TECHNICAL SPECIFICATIONS Temperature range: -50ºC to +99ºC type: NTC Total accuracy ( + controller): ±1ºC lead extension with cable AKO-15586:

More information

OPERATING AND MAINTENANCE MANUAL

OPERATING AND MAINTENANCE MANUAL OPERATING AND MAINTENANCE MANUAL AUTOMATIC SCREEN FILTER FMA SERIE 5000 Sistemas de Filtrado y Tratamiento de Fluidos S.A. Pol. Industrial La Armentera Parc. 86 INDEX INTRODUCTION...3 TECHNICAL CHARACTERISTICS...5

More information

Incubator with mechanical convection

Incubator with mechanical convection BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,

More information

Display units With alphanumeric screen

Display units With alphanumeric screen Display units With alphanumeric screen Compact display units Display Capacity lines, 0 characters 4 lines, 0 characters Back-lit LCD, green Back-lit LCD, green Back-lit LCD, 3 colours: green, orange, red

More information

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method G8 GALILEO High-End Melt-extraction Analyzer Innovation with Integrity Inert Gas Method Determination of O, N and H The market demands Metals, minerals, and inorganic compound markets demand high-quality

More information

6.2.2 TECHNICAL ARGUMENTS FOR OWN SCADA AND OWN SCADA WITH PID CONTROL.

6.2.2 TECHNICAL ARGUMENTS FOR OWN SCADA AND OWN SCADA WITH PID CONTROL. 1/9 www.edibon.com Ref: 6.2.2 TECHNICAL ARGUMENTS FOR OWN SCADA AND OWN SCADA WITH PID CONTROL. About 600 units in EDIBON product range are considered as advanced units. Why do we consider them advanced

More information

Refrigeration Compressed Air Dryer Buran Ultrapulse

Refrigeration Compressed Air Dryer Buran Ultrapulse Refrigeration Compressed Air Dryer Buran Ultrapulse There is more to compressed air than just compressing air Compressed air is an indispensable source of operating and processing power in all areas of

More information

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system FIRE ALARM SYSTEM reliable fire detection and alarm signalling system Satel fire alarm devices allow to implement reliable and modern systems responsible for fire safety. A combination of 20-year experience

More information

Computer Controlled Chemical Reactors Trainer, with SCADA and PID Control QRC

Computer Controlled Chemical Reactors Trainer, with SCADA and PID Control QRC Technical Teaching Equipment Computer Controlled Chemical Reactors Trainer, with SCADA and PID Control QRC EDIBON SCADA System and PID CONTROL included Teaching Technique used 1 QUSC. Service Unit 5 6

More information