ALCATEL OMNIPCX OFFICE
|
|
|
- Ethan Garrett
- 10 years ago
- Views:
Transcription
1 ALCATEL OMNIPCX OFFICE REF: 3EH21017BSAA Ed. 02
2
3 GENERAL INDEX Section ALCATEL OMNIPCX OFFICE REF: 3EH21017BSAA Ed. 02 Copyright ALCATEL All rights reserved. Alcatel Business Systems, in keeping with its policy of constant product improvement for the customer, reserves the right to modify product specifications without prior notice.
4
5 Alcatel OmniPCX Office GENERAL INDEX REF: 3EH21017BSAA Ed. 02
6
7 ALCATEL OMNIPCX OFFICE GENERAL INDEX General Index Symbols 'Please Wait' message Presentation of boards File 4 p. 4 Please wait message Connection File 6 p. 16 CPU boards File 6 p. 5 A Alarm Connection File 6 p. 17 CPU boards File 6 p. 5 Presentation of boards File 4 p. 4 Alcatel Reflexes terminals Connecting File 6 p. 11 Powering on File 6 p. 22 UAI board File 6 p. 6 Analog terminals Connecting File 6 p. 11 Doorphone File 6 p. 20 MIX X/Y/Z boards File 4 p. 8 Replacing File 15 p. 1 SLI board File 6 p. 6 SLI-X boards File 4 p. 8 Software key File 5 p. 3 B Background music Connection File 6 p. 17 CPU boards File 6 p. 5 Software key File 5 p. 4 Base stations File 8 p. 2 Batteries Characteristics File 16 p. 1 Maintenance File 16 p. 1 Recommendations File 3 p. 1 Replacing File 6 p. 21 Ed. 02 Ref. 3EH BSAA 1/6
8 ALCATEL OMNIPCX OFFICE GENERAL INDEX Battery maintenance File 16 p. 1 C Cables File 6 p. 7 Configuration Fast IP Reflexes File 9 p. 1 Network File 10 p. 1 PC File 13 p. 1 Web browser File 10 p. 1 Connecting Auxiliary equipment File 6 p. 16 CPU boards File 6 p. 8 Lan File 6 p. 15 Terminals File 6 p. 11 Connection Boards File 4 p. 4 DECT base stations File 8 p. 1 e-reflexes File 9 p. 1 mains File 6 p. 22 UPS File 6 p. 21 CPU-CPUe Boards Changing File 16 p. 3 D DECT base station ARI number File 12 p. 6 DECT Base Stations Installation File 8 p. 1 DECT base stations Positioning File 8 p. 3 DNS File 14 p. 5 Doorphone Connection File 6 p. 19 CPU boards File 6 p. 5 Presentation of boards File 4 p. 4 E Easy View File 13 p. 1 EasyPlus View File 13 p. 1 Expert View File 13 p. 1 Extension module Adding File 15 p. 6 Presentation of boards File 4 p. 4 Extension unit Transfer File 15 p. 2 Extension units 2/6 Ref. 3EH BSAA Ed. 02
9 ALCATEL OMNIPCX OFFICE GENERAL INDEX Adding File 7 p. 3 External loudspeaker Connection File 6 p. 18 CPU boards File 6 p. 5 G General bell Presentation of boards File 4 p. 4 General call ringer CPU boards File 6 p. 5 General ringer Connection File 6 p. 18 H Hard disk Maintenance File 16 p. 4 Hardware Reception File 4 p. 1 Vibrations File 6 p. 3 I Installation synopsis File 4 p. 3 Interfaces Classification File 3 p. 2 Internet Access File 14 p. 1 Boards File 4 p. 7 Client PCs File 10 p. 1 Connection test File 14 p. 7 Software key File 5 p. 3 Subscription File 14 p. 2 L LAN Internet File 14 p. 1 LAN boards File 4 p. 10 LEDs File 4 p. 6, 7 Software key File 5 p. 3 LEDs Function File 4 p. 6, 7 Loudspeaker Presentation of boards File 4 p. 4 Ed. 02 Ref. 3EH BSAA 3/6
10 ALCATEL OMNIPCX OFFICE GENERAL INDEX M Microswitches File 4 p. 6, 7 Module Racks File 4 p. 2, 12 Multi Reflexes DECT base stations File 15 p. 3 Use File 15 p. 3 music player Presentation of boards File 4 p. 4 P PM5 Fast IP Reflexes File 9 p. 2 Features File 13 p. 4 Installation File 13 p. 4 loading software key File 16 p. 3 Saving File 15 p. 4 Software key File 5 p. 2 Startup File 13 p. 1 R Recommendations Conformity File 3 p. 1 DECT File 8 p. 3 Directives File 3 p. 2 Earthing File 6 p. 22 Environmental protection File 8 p. 4 Environments File 6 p. 3 General File 3 p. 1 Site File 6 p. 3 Reflexes terminals Adding File 15 p. 4 Advanced terminals File 12 p. 1 Display File 12 p. 1 Fastening First and Easy terminals File 7 p. 5 First and Easy terminals File 11 p. 2 Installation File 7 p. 1 Installing Premium and Advanced terminals File 7 p. 1 Moving File 15 p. 2 Premium and Advanced terminals File 11 p. 1, 2 Presentation of boards File 4 p. 4 Profile File 11 p. 1 Replacing File 15 p. 1 Soft keys File 12 p. 1 Software key File 5 p. 3 4/6 Ref. 3EH BSAA Ed. 02
11 ALCATEL OMNIPCX OFFICE GENERAL INDEX UAI-X boards File 4 p. 8 S Software key Changing File 5 p. 2 Hardware reception File 4 p. 1 Services controlled File 5 p. 3 Wizard File 13 p. 6 Software keys Definition File 5 p. 1 U Using batteries File 6 p. 21 V Ventilation system Maintenance File 16 p. 1 Ed. 02 Ref. 3EH BSAA 5/6
12 ALCATEL OMNIPCX OFFICE GENERAL INDEX 6/6 Ref. 3EH BSAA Ed. 02
13 Alcatel OmniPCX Office Installation manual SECTION REF: 3EH21017BSAA Ed. 02
14
15 ALCATEL OMNIPCX OFFICE Section Installation manual REASONS FOR CHANGING ISSUE FILE 1 SYMBOLS USED IN THIS MANUAL FILE 2 SAFETY FILE 3 PRESENTATION OF THE HARDWARE FILE 4 SOFTWARE KEYS FILE 5 INSTALLATION / WIRING FILE 6 INSTALLING REFLEXES TERMINALS FILE 7 INSTALLING DECT BASE STATIONS FILE 8 INSTALLING FAST IP REFLEXES TERMINALS FILE 9 INSTALLING CLIENT PCS FILE 10 DEFAULT CONFIGURATION FILE 11 STARTING UP THE SYSTEM FROM AN ADVANCED TERMINAL FILE 12 STARTING UP THE SYSTEM WITH PM5 FILE 13 INSTALLATION OF AN INTERNET ACCESS FILE 14 UPGRADING YOUR SYSTEM FILE 15 FIRST-LEVEL MAINTENANCE FILE 16 GLOSSARY FILE 17 Ed. 02 Réf. 3EH21017BSAA 1/2
16 ALCATEL OMNIPCX OFFICE SECTION (INDEX) Section Installation manual (Index) DEFAULT CONFIGURATION FILE 11 FIRST-LEVEL MAINTENANCE FILE 16 GLOSSARY FILE 17 INSTALLATION / WIRING FILE 6 INSTALLATION OF AN INTERNET ACCESS FILE 14 INSTALLING CLIENT PCS FILE 10 INSTALLING DECT BASE STATIONS FILE 8 INSTALLING FAST IP REFLEXES TERMINALS FILE 9 INSTALLING REFLEXES TERMINALS FILE 7 PRESENTATION OF THE HARDWARE FILE 4 REASONS FOR CHANGING ISSUE FILE 1 SAFETY FILE 3 SOFTWARE KEYS FILE 5 STARTING UP THE SYSTEM FROM AN ADVANCED TERMINAL FILE 12 STARTING UP THE SYSTEM WITH PM5 FILE 13 SYMBOLS USED IN THIS MANUAL FILE 2 UPGRADING YOUR SYSTEM FILE 15 2/2 Réf. 3EH21017BSAA Ed. 02
17 REASONS FOR CHANGING ISSUE REASONS FOR CHANGING ISSUE File 1 In relation to issue 01 of the manual, this issue adds the following changes: - Sheet 4 "Hardware description": change in consumption for each model. - Sheet 6 "Installation/Cabling": adds the description of how to attach Rack1 and Rack 2 models to the wall. details on recommendations for choice of site. modification of characteristics of relay contacts used to connect auxiliary equipment. modification of the characteristics of the battery fuse. deletion of consumption. - modification of length of system downtime. - Sheet 14 "Installation of Internet access": add procedures for connection by DSL modem and LAN to LAN routing - Sheet 16 "First level maintenance": add recommendations on battery and cell maintenance. Ed. 02 Réf. 3EH21017BSAA 1/2
18 REASONS FOR CHANGING ISSUE 2/2 Réf. 3EH21017BSAA Ed. 02
19 SYMBOLS USED IN THIS MANUAL SYMBOLS USED IN THIS MANUAL File 2 Indicates a remark. Indicates important information. Ed. 02 Réf. 3EH21017BSAA 1/2
20 SYMBOLS USED IN THIS MANUAL 2/2 Réf. 3EH21017BSAA Ed. 02
21 SAFETY SAFETY File 3 DECLARATION OF CONFORMITY We, Alcatel Business Systems 32, avenue Kléber Colombes Cedex - France declare that the following products are deemed to comply with the requirements of Directive 1999/ CE/5 of the European Parliament and the Council. Any unauthorized modification of the products makes this declaration of conformity null and void. Pursuant to the directive, as published in the Official Journal of the European Community of April 7, 1999, these appliances can be used in all the countries of the European Community, Switzerland and Norway. Alcatel Business Systems All rights reserved. Alcatel Business Systems, in keeping with its policy of constant product improvement for the customer, reserves the right to modify product specifications without prior notice. Alcatel Business Systems - 32, avenue Kléber F Colombes Cedex RCS Paris GENERAL RECOMMENDATIONS It is vitally important to connect this product to a permanent ground connection installed in accordance with the rules of the art. Owing to the presence of hazardous voltages, the metal back plate may only be removed by suitably qualified personnel. In the event of a poor earth connection, it is IMPERATIVE to disconnect the telecommunications ports before reconnecting the earth. A check must then be made to ensure that all the connections have been made correctly. If it is necessary to intervene in the power supply unit, disconnect the mains cable before removing the metal panel on the power supply unit and disconnect the batteries. Ed. 02 Réf. 3EH21017BSAA 1/2
22 SAFETY DECLARATION OF CONFORMITY WITH DIRECTIVES This appliance is designed to be connected to the public telephone network through appropriate interfaces. The CE marking indicates that the product complies with prevailing community directives, in particular: - 89/336/CEE (Electromagnetic compatibility) - 73/23/CEE (Low voltage) /5/CE (R&TTE) CLASSIFICATION OF INTERFACES SELV: Safety Extra Low Voltage TNV-3: Telecommunications Network Voltage Alcatel OmniPCX Office UAI Reflexes 4070 base station SELV Mains power PS Z station SLI TNV-3 HSL CPU SELV 12 V/300 ma SELV SELV ISDN BRA PRA CPU Audio In/Out Management SELV SELV V24/MMC SELV TL TNV-3 ATA Ethernet CPU LanX 10/100 Base T SELV 2/2 Réf. 3EH21017BSAA Ed. 02
23 PRESENTATION OF THE HARDWARE PRESENTATION OF THE HARDWARE File 4 Alcatel OmniPCX Office is an "e-communication server", a new "All-in-One" concept combining proven telephony functions with access to all the resources of the Internet and data transmission. This "multipurpose" server is a turnkey global communications solution for small and medium-scale enterprises, with anything from 6 to 200 employees. RECEPTION OF THE HARDWARE The Alcatel OmniPCX Office module is delivered: - equipped with all the sub-assemblies necessary for your particular configuration. - configured with the software key corresponding to the desired levels of service (depending on country). The terminals are packed separately. Ed. 02 Réf. 3EH21017BSAA 1/14
24 PRESENTATION OF THE HARDWARE PRESENTATION OF THE MODULE Alcatel OmniPCX Office is available in three models. Rack 1-28 ports, - 1 CPU/CPUe slot and 2 reversible slots (no SLI16 board). - Energy consumption: 1A / 70 W. - Dimensions: H = 66 mm; W = 442 mm; D = 400 mm. - Weight: 6 kg. Rack 2-48 ports. - 1 CPU/CPUe slot and 5 reversible slots. - Energy consumption: 2 A / 100 W. - Dimensions: H = 110 mm; W = 442 mm; D = 400 mm. - Weight: 11 kg. Rack 3-96 ports. - 1 CPU/CPUe slot + 4 reversible slots + 4 specific slots (no UAI16 and MIX boards). - Energy consumption: 2,3 A / 150 W. - Dimensions: H = 154 mm; W = 442 mm; D = 400 mm. - Weight: 13 kg. 2/14 Réf. 3EH21017BSAA Ed. 02
25 File 4 PRESENTATION OF THE HARDWARE INSTALLATION SYNOPSIS Z Fax Private Network (Q SIG/ ISVPN) Analog station Analog Public Network 4970 IO/EO DECT base Z - Integrated voice server - Integrated CTI server Z Multi Reflexes LAN Integrated Internet applications: - Internet access - Proxy s erver - Cache s erver - Firewall -Mail server Z Reflexes Stations - First - Easy - Premium - Advanced Pulse metering - Elitecost - Printer Z PM5 General call ringer Doorphone Loudspeaker 10 base T Z e-reflexes "Please wait" music Background music Auxiliaries TAPI 2.1 or CSTA Server This equipment must be installed by a qualified installation technician. Ed. 02 Réf. 3EH21017BSAA 3/14
26 PRESENTATION OF THE HARDWARE DESCRIPTION OF THE BOARDS BOARDS FUNCTIONS OPTIONAL BOARDS CONNECTIONS ATA2 ATA4 BRA-2 BRA-4 BRA-8 2 or 4 analog trunk line terminals 2, 4 or 8 T0 basic accesses CPU, CPUe Processing Unit CoCPU, CoCPU@ LanX8 LanX16 MEX (with HSL1 board) MIX244 MIX484 MIX448 MIX044 MIX084 MIX044 PRA-T1 PRA-T2 DASS2 DLT2 CoProcessing Unit 8 or 16 ports 10/100 BT Ethernet Controller for extension modules 0, 2 or 4 T0 basic accesses + 4 or 8 UA interfaces + 4 or 8 Z interfaces PRA -T2, DASS2, DLT2: 30 B-channels + 1 D- channel; 2048 kbps) PRA-T1: 23 B-channels + 1 D-channel; 1544 kbps MET: pulse meter receiver HSL1, HSL2: interconnection with extension modules XMEM: extended memory and/or IDE interface for the hard disk VoIP: Voice over IP (e-xs model) AFU: auxiliary functions VoIP: Voice over IP SLANX: mini switch (CPU/CPUe - CoCPU/CoCPU@)link Analog Trunk Line (TL) and TL- SUBS diversion ISDN network Hub, Lan switch or Ethernet terminal "Please Wait" message device Background background music Alarm Doorphone Loudspeaker. General bell Pulse metering device PC PM5 Hub, LAN switch or Ethernet Phones, LAN switch, Hub, etc... ISDN network, Analog Z terminals and Alcatel Reflexes terminals PRA-T2: ISDN network DASS2 UK public/private network DLT2: QSIG private network PRA-T1: Hong-Kong ISDN network 4/14 Réf. 3EH21017BSAA Ed. 02
27 File 4 PRESENTATION OF THE HARDWARE SLI-4 SLI-8 SLI-16 UAI-4 UAI-8 UAI-16 4, 8 or 16 Z interfaces Z analog terminals 4, 8 or 16 UA interfaces Alcatel Reflexes terminals Multi Reflexes DECT 4070IO/EO base stations Ed. 02 Réf. 3EH21017BSAA 5/14
28 PRESENTATION OF THE HARDWARE CPU / CPUe Boards These boards perform the system's central processing unit functions. PROCESSING UNIT CPU PROCESSING UNIT CPUe LAN AUDIO-OUT CONFIG LAN WAN AUDIO-OUT CONFIG LAN FAN POWER LAN WAN FAN POWER MODULE 1 MODULE 2 AUDIO-IN DOORPHONE MODULE CPU MODULE 1 MODULE 2 AUDIO-IN DOORPHONE MODULE CPU The CPUe board of Alcatel OmniPCX Office's e-xs solution offers all of the following features: - System central processing unit - Voice over IP - Internet Access Function of the LEDs Name Color Function CPU Green CPU correct operation LED (flashing) POWER Two-colored Red/ Green - Running on mains power: green LED on steady - Running on battery: yellow LED on steady - Standby mode: red LED flashing FAN Two-colored Red/ Green - 2 fans operating correctly: green LED on steady - 1 or 2 fans KO: red LED on steady LAN Green LAN correct operation LED (flashes to signal traffic) MODULE Green HSL board installed WAN Green Not in use CPU/CPUe board microswitch settings On /14 Réf. 3EH21017BSAA Ed. 02
29 File 4 PRESENTATION OF THE HARDWARE CoCPU / CoCPU@ Boards These boards perform the following functions: - CoCPU: Voice over IP and IP Telephony - CoCPU@: Internet Access, server, Proxy and VPN. COPROCESSING UNIT CoCPU COPROCESSING UNIT CoCPU@ LAN LAN WAN LAN LAN WAN UNIT1 UNIT 2 UNIT 3 UP-LINK UNIT1 UNIT 2 UNIT 3 UP-LINK CPU UNIT1 UNIT 2 UNIT 3 UP-LINK UNIT1 UNIT 2 UNIT 3 UP-LINK CPU Function of the LEDs Name Color Function CPU Green CPU correct operation LED (flashing) LAN Green LAN correct operation LED (flashes to signal traffic) WAN Green WAN Correct operation LED (flashes to signal traffic); used if there is an ADSL modem connection. Available from release R1 onwards. UNIT 1-4 UPLINK Green LAN interfaces Switches 1 to 4 correct operation LED (flashing) Microswitch settings On On CoCPU board CoCPU@ board Ed. 02 Réf. 3EH21017BSAA 7/14
30 PRESENTATION OF THE HARDWARE SLI-X boards These boards allow for the connection of 4, 8 or 16 analog terminals. ANALOG INTERFACES SLI UAI-X boards These boards can connect up 4, 8 or 16 Alcatel Reflexes stations or DECT 4070 IO/EO base stations. DIGITAL INTERFACES UAI MIX X/Y/Z boards These boards can connect up 2 or 4 T0 basic accesses, 4 or 8 analog terminals and 4 or 8 Alcatel Reflexes stations. MIXED MIX 4/8/4 MIXED MIX 4/4/8 ISDN T0 ANALOG INTERFACES ISDN T0 ANALOG INTERFACES DIGITAL INTERFACES DIGITAL INTERFACES ANALOG INTERFACES 8/14 Réf. 3EH21017BSAA Ed. 02
31 File 4 PRESENTATION OF THE HARDWARE BRA-X boards These boards can connect up 2, 4 or 8 T0 basic accesses (2 B-channels+1 D-channel). ISDN ACCES - T0 BRA PRA boards This board connects up a primary access (PRA-E1: 30 B-channels + 1 D-channel; PRA-T1: 23 B-channels + 1 D-channel). ISDN ACCESS - E1 PRA- T2 BUSY RAI AIS NETW PBX NOS CRC LOS Function of the LEDs Name of T2 Name of T1 Function BUSY BUSY B-channels busy (red LED lit if at least 1 B-channel is busy) RAI (ATD) RAI Remote frame alarm (red LED lit if alarm) AIS (SIA2M) AIS Too many "1"s in the 2-megabit binary train (red LED lit if alarm) NOS (MS) NSIG 2-megabit signal missing (red LED lit if alarm) CRC (TE) CRC CRC error (red LED lit if alarm) LOS (PVT) NSYN Loss of frame alignment (red LED lit if alarm) Ed. 02 Réf. 3EH21017BSAA 9/14
32 PRESENTATION OF THE HARDWARE ATA-X boards This board allows for connection to the analog public network (2 or 4 TLs). ANALOG TRUNK ACCESS ATA SLI PHONE LAN X8, LAN X16 boards These boards allow for the creation of a local area network (LAN) by connecting client PCs, IP-Phone, external LAN switches and servers. ETHERNET LANSWITCH LAN X 8 ETHERNET LANSWITCH LANX UP-LINK UP-LINK Each RJ45 connector (category 5) incorporates 2 green LEDs: - Left LED = link and activity status: off: link disconnected on: link connected - flashing: link active - Right LED = full duplex/collision: off: Half Duplex on: Full Duplex - flashing: collision 10/14 Réf. 3EH21017BSAA Ed. 02
33 File 4 PRESENTATION OF THE HARDWARE EQUIPPING THE CPU BOARDS WITH DAUGHTER/SDRAM BOARDS The following table describes the different possibilities for fitting daughter boards on the various CPU boards. DAUGHTER CPU / CPUe CoCPU / CoCPU@ BOARDS CPU CPUe CoCPU CoCPU@ SDRAM32 Yes No Yes No SDRAM64 No Yes No No SDRAM128 No Yes, on CPUe model e-xs only No Yes XMEM Yes Yes No No VoIP No Yes on CPUe Yes No model e-xs HSL1 Yes Yes No No HSL2 Yes Yes No No AFU Yes Yes No No WAN No No No Yes SLANX4 No No Yes Yes HARD DISK Yes Yes No Yes Example of fitting daughter boards on a CPUe SDRAM module 2,5 hard disk on metal support (Option) VoIP or XMEM HSL1 (Option) AFU (Option) Ed. 02 Réf. 3EH21017BSAA 11/14
34 PRESENTATION OF THE HARDWARE FITTING THE BASIC MODULE Rack 1 SLO T1 SLOT2 SLOT C PU BOARD SLOT 1 SLOT 2 CPU SLOT CPU, CPUe No No Obligatory MIX x/y/z Yes + Yes No UAI4, UAI8, UAI16 Yes + Yes No SLI4, SLI8 Yes + Yes No SLI16 No No No PRA-T2, PRA-T1, DASS2, Yes Yes + No DLT2 ATA2, ATA4 Yes Yes + No BRA2, BRA4, BRA8 Yes Yes + No CoCPU, CoCPU@ Yes Yes + No LANX8, LANX16 Yes Yes + No Empty slot blanking cover Yes Yes No Yes +: recommended slot Rack 2 SLO T1 SLO T2 SLO T CPU SLO T3 SLO T4 SLO T5 BOARD SLOT 1-3: SLOT 2-4 SLOT 5 CPU SLOT CPU, CPUe No No No Obligatory MIX x/y/z Yes + Yes Yes No UAI4, UAI8, UAI16 Yes + Yes Yes No SLI4, SLI8, SLI16 Yes + Yes Yes No PRA-T2, PRA-T1, DASS2, Yes Yes + Yes No DLT2 ATA2, ATA4 Yes Yes + Yes No 12/14 Réf. 3EH21017BSAA Ed. 02
35 File 4 PRESENTATION OF THE HARDWARE BRA2, BRA4, BRA8 Yes Yes + Yes No CoCPU, CoCPU@ Yes Yes Yes + No LANX8, LANX16 Yes Yes Yes + No Empty slot blanking cover Yes Yes Yes No Yes +: recommended slot Rack 3 SLO T1 SLO T2 SLO T C PU SLO T3 SLO T4 SLO T5 SLO T6 SLO T7 SLOT8 BOARD SLOT SLOT 5-8 SLOT 6-7 CPU SLOT CPU, CPUe No No No Obligatory MIX x/y/z Yes No No No UAI4, UAI8 Yes + Yes Yes No UAI16 Yes + No No No SLI4, SLI8, SLI16 Yes + Yes Yes No PRA-T2, PRA-T1, DASS2, Yes Yes Yes + No DLT2 ATA2, ATA4 Yes Yes Yes + No BRA2, BRA4, BRA8 Yes Yes Yes + No CoCPU, CoCPU@ Yes Yes + Yes No LANX8, LANX16 Yes Yes + Yes No Empty slot blanking cover Yes Yes Yes No Yes +: recommended slot Ed. 02 Réf. 3EH21017BSAA 13/14
36 PRESENTATION OF THE HARDWARE 14/14 Réf. 3EH21017BSAA Ed. 02
37 SOFTWARE KEYS SOFTWARE KEYS File 5 A software key identifies a list of authorized services and their modalities of use. Each system is assigned 2 software keys: Main (= essentially voice services) and CTI. Software keys are derived from - a serial number associated with the system CPU/CPUe board - a set of unction access rights (system or CTI) When the system is booted there are three possibilities: 1. The key present in the system is correct: the system starts with the level of services provided by this key. 2. There is a key in the system, but the serial number indicated in the key differs from the system CPU serial number: the system starts with the level of services provided by the key with temporary validity (30 days). The operator terminal display indicates "Software key problem"; pressing the Alarm key indicates the key expiry date. Entering a valid key (with the right serial number) during the period of temporary validity changes the system to state 1, otherwise the system switches to state 3 at the end of the period, resets itself and reboots in "limited" mode. 3. There is no key, or the time-out has expired: the system boots with the "limited" mode capabilities described below. Entering a valid key (with the right serial number) resets the system and switches it to state 1. Voice services available in "limited" mode - Terminals in the default Attendant Group and analog terminals with automatic call setup on going off-hook - No DECT terminals, including Reflexes DECT terminals - Voice server with name announcement, 2 ports and 20 minutes storage - 4 welcome messages (pre-announcement) - ARS - 2 system languages - "Please Wait" music: 2minutes max. - Personal Assistant - DISA - all the other services are closed. Ed. 02 Réf. 3EH21017BSAA 1/6
38 SOFTWARE KEYS CHANGING THE KEY In BTCO mode, the software key is pre-loaded by the maker; in "stock mode" (post-sale), the key has to be entered by the distributor. When updating the system, the installer has to modify the key to take on board new services. The key can be changed using PM5 or MMC-Station. PM5 procedure - To read the CPU board serial number: select Modification Typical -> System Software Key -> Hardware Serial Number - Indicate this serial number and the desired levels of services to Alcatel. - Load the key file Main.msl or CTI.csl from the Alcatel Business Partner web site (this file can also be downloaded by the maker). - Load the new key: Select Modification Typical -> System ->Software Key Click Import Key In the Open screen, select the file corresponding to the new key Confirm - In the System screen, click Apply. - To open some of the features requires a hot reset; a message is displayed. If the necessary hardware for the features unlocked by the software key is not present, the services are automatically reduced to adapt to the hardware available; an error message is displayed when the key is entered. It is possible to find out the access rights to the various services controlled by the key. In PM5, select Modification Typical -> System -> Software Key Click Details 2/6 Réf. 3EH21017BSAA Ed. 02
39 File 5 SOFTWARE KEYS SERVICES CONTROLLED BY THE "MAIN " SOFTWARE KEY The following table lists the services controlled by the "Main" software key, the "limited" mode values and the configuration modularity. Services controlled Number of Reflexes terminals Number of analog terminals Number of DECT + DECT Reflexes terminals Values in "limited" mode Modularity According to selected mode Max Limit without X-MEN STANDARD TELEPHONY Limit with X- MEN 64 Limit with HARD DISK MOBILITY CALL MANAGEMENT ARS open open open open open DISA / DISA transit open open open open open ISVPN on ISDN closed open open open open QSIG + closed open open open open NETWORKS Number of B-channels in digital networks Internet access closed open access Proxy: Web cache closed open and Access control E mail closed open Internet VPN closed open Internet access on CoCPU NO YES INTERNET ACCESS LAN TELEPHONY Ed. 02 Réf. 3EH21017BSAA 3/6
40 SOFTWARE KEYS Services controlled Number of IP Phones Number of PIM-telephony Multimedia terminals VoIP GATEWAY Number of VoIP channels VoIP VoIP on CoCPU NO YES VOICE MAIL AND AUTOMATED ATTENDANT Number of VMU 2 ports ports Storage capacity h 20 1h20 200h Automated attendant closed open closed open & nonconfigurable* open & configurable Audiotext closed open closed closed open Fax switching closed open open open open Mailbox welcome closed open open open open messages Name in the distribution closed open closed closed open lists Recording closed open closed closed open conversations WELCOME Number of messages (16") "PLEASE WAIT" MUSIC Duration 2 min. 2 min min. PULSE METERING Number of NMC tickets Values in "limited" mode Modularity Max Limit without X-MEN Limit with X- MEN 64 Limit with HARD DISK /6 Réf. 3EH21017BSAA Ed. 02
41 File 5 SOFTWARE KEYS Services controlled Number of languages Values in "limited" mode Modularity Max LANGUAGES Limit without X-MEN Limit with X- MEN 64 Limit with HARD DISK * The Automated Attendant cannot be configured; only the company welcome message can be recorded, with a maximum duration of 16. Ed. 02 Réf. 3EH21017BSAA 5/6
42 SOFTWARE KEYS 6/6 Réf. 3EH21017BSAA Ed. 02
43 INSTALLATION / WIRING INSTALLATION / WIRING File 6 INSTALLATION OF THE CASE The Alcatel OmniPCX Office case can be installed in three ways: - Placed on a table: a maximum of three cases can be mounted on top of one another. - Attached directly to the wall: a kit can be used to attach the Rack 1 and Rack 2 models to the wall. - Mounted in a computer bay (rack): the case is secured in the rack by means of the attaching brackets provided by the rack supplier, or using the optional 19" installation kit (there is a kit for each type of module). Wall mounting (Rack1 and Rack2 only) The wall-mounting kit is made up of 4 mechanical parts. After the case has been fitted, the space between it and the wall can be used to run cables through. Ed. 02 Réf. 3EH21017BSAA 1/22
44 INSTALLATION / WIRING Installation in the 19" rack Left-hand support rail Right-hand support rail Unit locking studs 2/22 Réf. 3EH21017BSAA Ed. 02
45 File 6 INSTALLATION / WIRING Recommendations: Before installing a system in a 19 rack it must be ensured that: - the maximum static load (given by the supplier) of the 19 rack is greater than the total weight of the appliances fitted to or to be fitted to the rack. - In addition, the weight of the appliances must be distributed uniformly throughout the height of the struts. - If the Alcatel OmniPCX Office module were to exceed the load on the front struts when fitted (in general it equates to the total load of the rack divided by 2), then the module must be placed on a tray attached to the 4 struts of the bay. ENVIRONMENT Climatic conditions Operation: - Temperature : to ensure optimum reliability, an ambient temperature range between 5 C and 40 C is recommended, with temperature variation not exceeding 5 C per hour. - Relative humidity: relative humidity must be between 10 % and 80 % (without condensation) with a variation rate not exceeding 10% per hour. Storage: - Temperature : storage temperature must be between -20 C and + 70 C. - Relative humidity: relative humidity must be between 10 % and 95 % (non-condensing). Vibrations The equipment must not be subjected to any vibration, even intermittent. Site - Choose a dry, clean and properly ventilated site. - Maintain an ambient air flow to ensure normal operation. If the air flow is blocked or restricted, or the incoming air is too warm, there is a risk of overheating. - When you install the equipment in a closed 19" rack, make sure that the rack is fitted with a ventilation system that is able to dissipate the heat of the installed equipment. Leave a minimum of 3 cm free space around the side ventilation slits (LH and RH side), and at least 10 cm around the ventilation slits at the back of the equipment. Make sure that the air flow is not blocked on the sides of the rack. - When you attach the system directly to the wall using the wall-mounting kit (Rack 1 and Rack 2 only), leave a free space of 15 cm all around the system. Take care that no objects are placed on Ed. 02 Réf. 3EH21017BSAA 3/22
46 INSTALLATION / WIRING the top part of the system, thus restricting the extraction of hot air. In the case where multi-cases are installed, choose horizontal alignment of the cases. If the cases are placed one on top of the other, leave at least 10 cm between them. - Make sure that the connecting cables of the Alcatel OmniPCX Office case or any other item of equipment, or the struts of the receiving structure (19" rack for example) do not obstruct the air flow through the case. - Have a 230 V or 110 V (depending on country) - 50Hz (2P+E) mains power outlet installed no more than one metre from the case if it is not installed in a rack (otherwise the cutout incorporated into the rack is used). - The room must have suitable lighting. 4/22 Réf. 3EH21017BSAA Ed. 02
47 File 6 INSTALLATION / WIRING OUTPUT CONNECTORS All outputs are made via RJ45 female connectors. CPU / CPUe boards Front panel RJ45 female connector RJ45 pin LAN TX+ TX- RX+ RX- AUDIO-OUT Audio Audio Alarm CenRg CenRg Alarm Ground +12 V Out A Out B A A B B CONFIG CTS DSR RX Ground Ground TX DTR RTS MODULE1 TX+ TX- RX+ RX- MODULE2 TX+ TX- RX+ RX- AUDIO-IN DOORPHONE Audio In A Audio In B Audio Ctrl A DoorPh B1 DoorPh A1 DoorPh A2 Audio Ctrl B DoorPh B2 - LAN: Ethernet 10/100 Base T (MDI-II/straight wiring), for interconnection with CoCPU or LAN. - AUDIO-OUT: Interfaces: External loudspeaker, alarm, general call ringer; 12V output - AUDIO-IN: Interfaces: "please wait" message, background music. - DOORPHONE: Interfaces: doorphone. - CONFIG : RS232 for PM5. - MODULE1: HSL link for interconnection with extension cabinet 1. - MODULE2: HSL link for interconnection with extension cabinet 2. Ed. 02 Réf. 3EH21017BSAA 5/22
48 INSTALLATION / WIRING CoCPU / CoCPU boards, RJ45 pin LAN/WAN TX+ TX- RX+ RX- Up-link TX+ TX- RX+ RX- Unit 1 to 3 RX+ RX- TX+ TX- - LAN: Ethernet 10/100 Base T (MDI-II/straight wiring). - WAN: Ethernet 10/100 Base T (MDI-II/straight wiring); connection of an ADSL modem (available from version R1.1) - UNIT1, UNIT2, UNIT3: ports of integrated LAN Switch (MDI-X/crossed wiring). - UPLINK: up-link of integrated LAN Switch (MDI-II/straight wiring). SLI board RJ45 pin to 16 ZA ZB - 1 to 16: connection of Z analog terminals. UAI board RJ45pin to 16 L1 L2-1 to 16: connection of Alcatel Reflexes terminals or Alcatel 4070 IO/EO DECT base sets. BRA board RJ45 pin to 8 TX+ RX+ RX- TX- - 1 to 8: connection of T0 basic access. PRA board RJ45 pin NETW II RX+ RX- TX+ TX- PBX X TX+ TX- RX+ RX- 6/22 Réf. 3EH21017BSAA Ed. 02
49 File 6 INSTALLATION / WIRING - NETW II: connection with public network (TNL). - PBX X: use in a private network with crossed TX and RX pairs. LAN X board RJ45 pin Ports 1 to 15 RX+ RX- TX+ TX- Up-Link TX+ TX- RX+ RX- - Port 1 to 15: internal ports. - Up-Link: LAN connection. ATA board RJ45 pin to 4 PEA PEB SLI ZA1 ZB1 PHONE ZSET A ZSET B - 1 to 4: connection of analog trunk lines. - SLI: connection of the SLI interface of the TL diversion terminal - PHONE: connection of the TL diversion terminal. TYPES OF CABLE TO USE Access Type Impedance Alcatel Reflexes, Z, UTP, FTP or STP, Category 3 or or 120 Ohms T0, LR T2 UTP, FTP or STP, Category 3 or Ohms T1 UTP, FTP or STP, Category 3 or Ohms Ethernet UTP, FTP or STP, Category Ohms HSL STP provided with the product, Category Ohms - UTP: Unshielded Twisted Pairs - FTP: Foiled Twisted Pairs - STP: Shielded Twisted Pairs Ed. 02 Réf. 3EH21017BSAA 7/22
50 INSTALLATION / WIRING CONNECTING THE CPU / CPUe AND CoCPU / CoCPU BOARDS Configuration without SLANX4 (recommended configuration) 8/22 Réf. 3EH21017BSAA Ed. 02
51 File 6 INSTALLATION / WIRING CoCPU board + SLanX4 board COPROCESSING UNIT CoCPU CPU board COPROCESSING UNIT CoCPU LANX board External LAN Switch ETHERNET LANSWITCH LANX8 CPU board PROCESSING UNIT CPU General bell Loudspeaker Alarm 12V serviceable voltage PC (PM5, NMC) Doorphone MEX board (extension unit 1) ADD-ON MODULE MEX "Please wait" message Background music MEX board (extension unit 2) ADD-ON MODULE MEX Ed. 02 Réf. 3EH21017BSAA 9/22
52 INSTALLATION / WIRING Configuration with SLANX4 CoCPU board + SLanX4 board COPROCESSING UNIT CoCPU CPU board COPROCESSING UNIT CoCPU OR LANX board External LAN Switch ETHERNET LANSWITCH LANX8 CPU board PROCESSING UNIT CPU General bell Loudspeaker Alarm 12V serviceable voltage PC (PM5, NMC) Doorphone MEX board (extension unit 1) ADD-ON MODULE MEX "Please wait" message Background music MEX board (extension unit 2) ADD-ON MODULE MEX 10/22 Réf. 3EH21017BSAA Ed. 02
53 File 6 INSTALLATION / WIRING CONNECTING THE TERMINALS Connecting the Alcatel Reflexes terminals The terminals are equipped with a cable and a telephone jack to be plugged into a wall socket. Each terminal is connected by means of a pair of 0.5 or 0.6 mm diameter wires. System - Alcatel Reflexes terminal distances: - cable type SYT 0.5 mm: 800 m (terminal with no option) or 600 m (terminal with option S0 or Z). - cable type mm: 1200 m (terminal with no option) or 850 m (terminal with option S0 or Z). Distribution panel DIGITAL INTERFACES UAI16 L1 (4) L2 (5) Connecting analog terminals The terminals are equipped with a cable and a telephone jack to be plugged into a wall socket. Each terminal is connected by means of a pair of 0.5 or 0.6 mm diameter wires (1.3 km max with the 0.5 mm cable). ZA (4) ZA Distribution panel ANALOG INTERFACES SLI or ZB (5) ZB Ed. 02 Réf. 3EH21017BSAA 11/22
54 INSTALLATION / WIRING CONNECTION TO THE PUBLIC NETWORK Digital public network through T0 connection The Alcatel OmniPCX Office system can be installed near the DNT or remoted up to a specific distance (350 m maximum) depending on requirements. Distribution panel ISDN ACCESS - T0 BRA 8 Transmission TX DNT Reception RX Digital public network through T2 connection Distribution panel ISDN ACCESS - E1 PRA-T2 BUSY RAI AIS Transmission TX NETW PBX NOS CRC LOS DLT Reception RX The PRA board is connected to a digital line termination (DLT) by 2 symmetrical twisted pairs. Cabling impedance: 120 Ohms +/-20% between 200 khz and 1 MHz; 120 Ohms +/-10 % at 1 MHz. Using the L120 series cable (or equivalent L204) is preferred. The T2-DLT distance is limited by the attenuation between DLT and T2 which must not exceed 6 db at 1024 khz. 12/22 Réf. 3EH21017BSAA Ed. 02
55 File 6 INSTALLATION / WIRING Analog public network Without TL diversion Distribution panel ANALOG TRUNK ACCESS ATA ANALOG PUBLIC NETWORK PEA PEB Ed. 02 Réf. 3EH21017BSAA 13/22
56 INSTALLATION / WIRING With TL diversion In the event of a power supply failure or a computer fault, this solution enables the trunk connected to the first equipment of the ATA board to be diverted to one of the system's analog terminals. ANALOG INTERFACES SLI ANALOG TRUNK ACCESS ATA 4 Distribution panel SLI PHONE ANALOG PUBLIC NETWORK PEA PEB Analog Station 14/22 Réf. 3EH21017BSAA Ed. 02
57 File 6 INSTALLATION / WIRING CONNECTION OF THE LAN The LANX8/LANX16 board can be used to connect servers, PCs, Fast IP Reflexes, and external Switches. Alcatel SWITCH Ethernet 10/100 Mbits Ethernet 10/100 Mbits Server 1 Server 2 ETHERNET LANSWITCH Up-Link LANX8 PRO CESSING UNIT CPU Port 4 Port 3 Ethernet 10/100 Mbits Port 2 Ethernet 10/100 Mbits Host 1 Port 1 Host 2 Ethernet 10/100 Mbits Host 3 Ed. 02 Réf. 3EH21017BSAA 15/22
58 INSTALLATION / WIRING CONNECTING ANCILLARY EQUIPMENT All items of ancillary equipment are to be connected to the AUDIO-IN, AUDIO-OUT and DOOR- PHONE of the CPU/CPUe board. Connection of a "please wait" message device The connection is made through the AUDCTRL output (normally-open control contact) and the AU- DIN input of the AUDIO-IN connector. Distribution panel PROCESSING UNIT CPU AudCrtl A LAN AUDIO-OUT CONFIG LAN FAN PO WER Control circuit AudCrtl B MODULE 1 MODULE 2 AUDIO -IN DOORPHONE MODULE CPU Audio Circuit Audio In A Audio In B Power supply Audio input characteristics: - Input impedance: 600 Ohms Contact characteristics: - Max. power: : 10 W - Max. voltage: : 60 V - Max. current: : 500 ma The contacts of the alarm and doorphone controls have the same electrical characteristics as those indicated above. 16/22 Réf. 3EH21017BSAA Ed. 02
59 File 6 INSTALLATION / WIRING Connection of a background music tuner The background music tuner is connected through the AUDIN input of the AUDIO-IN connector. Distribution panel PROCESSING UNIT CPU LAN AUDIO -OUT CONFIG LAN FAN PO WER Audio In A MODULE 1 MODULE 2 AUDIO -IN DOORPHONE MODULE CPU TUNER Audio In B Power supply Audio input characteristics: - Input impedance: 600 Ohms - Input level: access + 10 dbr Connection of an alarm The alarm is activated in the event of a system failure. The alarm is connected through the ALARM output (normally-closed control contact) of the AUDIO- IN connector. Distribution panel PROCESSING UNIT LAN AUDIO-OUT CONFIG CPU LAN FAN PO WER Alarm system Alarm A MODULE 1 MODULE 2 AUDIO-IN DOORPHONE MODULE CPU Alarm B Power supply Ed. 02 Réf. 3EH21017BSAA 17/22
60 INSTALLATION / WIRING Connection of a external broadcasting loudspeaker The broadcasting loudspeaker is connected through the AUDOUT output of the AUDIO-OUT connector. Distribution panel PROCESSING UNIT CPU LAN AUDIO-OUT CONFIG LAN FAN PO WER Aud Out A MODULE 1 MODULE 2 AUDIO-IN DOORPHONE MODULE CPU Amplifier Aud Out B Power supply Audio output characteristics: - Output impedance: < 500 Ohms - Output level: access +3 dbr Connection of a general ringer The general ringer is connected through the CENRG output of the AUDIO-OUT connector. Distribution panel PROCESSING UNIT CPU LAN AUDIO-OUT CONFIG LAN FAN PO WER General call ringer CenRg A MODULE 1 MODULE 2 AUDIO-IN DOORPHONE MODULE CPU CenRg B Power supply 18/22 Réf. 3EH21017BSAA Ed. 02
61 File 6 INSTALLATION / WIRING Connection of a doorphone 2 families of doorphones are offered, depending on the operating mode used: - Type A: relay-controlled doorphones (for example: NPTT) - Type B: doorphones controlled by MF Q23 signals that require an SLI interface (for example: TE- LEMINI and UNIVERSAL DOORPHONE) The doorphone equipment comprises an interphone and an optional lock keeper supplied with mains power through a SELV-class transformer (Safety Extra Low Voltage). The doorphone is connected through the DOORPHA and DOORPHB outputs (normally-open control contacts) of the DOORPHONE connector. Connection of a type A doorphone Distribution panel PROCESSING UNIT CPU LAN AUDIO-OUT CONFIG DoorPhA1 LAN FAN POWER DOORPHONE DoorPhA2 MODULE 1 MODULE 2 AUDIO-IN DOORPHONE MODULE CPU To door ock keeper DoorPhB1 DoorPhB2 220V ANALOG INTERFACES SLI A - Only one doorphone with a lock keeper can be connected to the system. - The system allows the connection of 2 doorphones without lock keepers. Ed. 02 Réf. 3EH21017BSAA 19/22
62 INSTALLATION / WIRING Connection of a type B doorphone These doorphones require the use of a Z terminal interface. - Several doorphones of this type can be connected to the system; the limit is determined by the maximum number of analog terminals that the system can support. Distribution panel PROCESSING UNIT SLI16 A DOORPHONE B To door ock keeper DoorPhB1 DoorPhB2 220V Use of the 12 V outlet The GROUND and + 12V outlets of the AUDIO-OUT connector can be used to connect an external device supplied with 12 V where consumption does not exceed 150 ma (Rack 1 and Rack 2) or 300 ma (Rack 3). 20/22 Réf. 3EH21017BSAA Ed. 02
63 File 6 INSTALLATION / WIRING USING BATTERIES The system is supplied with its battery (batteries); these batteries are attached to a support and held in place by a collar that is part of the backpanel. Battery switch The batteries are isolated during transport by a switch soldered to the power supply board. Plugging the mains cable into the socket closes this switch by means of a lever integrated into the mains socket. Battery fuse The battery fuse is located on the board; the backpanel must be removed to access it. Fuse characteristics: - Rack1 and Rack2: 6.3 A quick-acting, low breaking capacity (F 6.3 AL/250 V) - Rack3: 10 A quick-acting, low breaking capacity (F 10 AL/250 V) Replacing the batteries Refer to this manual's Maintenance section. CONNECTION OF A UPS The UPS (Uninterruptible Power Supply) enables system data to be backed up for at least one hour in the event of a mains power failure. The UPS is connected through the mains connector at the back of the case. - UPS power supply: use the mains lead provided with the Alcatel OmniPCX Office module. - Connecting UPS - module: use the lead provided with the UPS If 3 Alcatel OmniPCX Office modules are to be installed, 2 UPS are required: one powering 2 modules and the other the third module. Ed. 02 Réf. 3EH21017BSAA 21/22
64 INSTALLATION / WIRING CONNECTION OF MAINS POWER - EARTHING The system can be connected to any type of electrical installation, including: - TT (local earth for each unit). - TN (common earth for all equipment). - IT with 230 V mesh voltage; possible only in Norway. Mains socket fuse: T2.5 AH / 250 V (time-delayed, high breaking capacity). The system is supplied with a 3-wire cable (length: 3 m) to be connected to the mains power socket. Permanent earth It is vital to connect the system permanently to earth because of the leakage currents that exceed 3.5 ma on all the trunk accesses (safety requirement CEI60950 ed.03). To achieve this, use the earthing wire provided with a minimum cross-sectional area of 4 mm 2 and connect it to the stud at the rear of the case (LH side). POWERING ON After making all the connections, power on the system. - Plug the mains cable into the socket at the back of the case. - Press the ON/OFF button of the CPU board. The system reboots (duration: 3 to 4 minutes). To switch off the system: - Press the ON/OFF button, the RED LED flashes. - Wait until the red LED stays on (between 15 seconds and 3 minutes depending on configurations): the system is powered off. Powering on Alcatel Reflexes terminals When switched on, Alcatel Reflexes terminals perform a test sequence: - Test of the display, - Test of the terminal LED or icons and extension unit if one is fitted, - Audio test. If this sequence is correct, the Alcatel Reflexes terminal display shows the system date: Monday 01 January After powering on, you can start using the system from an Advanced Reflexes terminal or by PM5 (refer to the specific section). 22/22 Réf. 3EH21017BSAA Ed. 02
65 INSTALLING REFLEXES TERMINALS INSTALLING REFLEXES TERMINALS File 7 REMINDER: DISTANCES FROM SYSTEM - cable type SYT, 0.5 mm: 800 m (terminal with no option) or 600 m (terminal with option S0 or Z). - cable type 278, 0.6 mm: 1200 m (terminal with no option) or 850 m (terminal with option S0 or Z). REFLEXES PREMIUM AND ADVANCED TERMINALS Installing the line cable - Turn the terminal upside down. - Remove the cover from the underside of the terminal (push inwards, then disengage it). - Plug in the line cable (connector ) and route it as shown below. - Reinstall the cover. Line cable (to wall socket) Cover Channel for line cable Receiver cord Installing the receiver cord - Turn the terminal upside down. - Plug in the receiver cord (connector ) and route it through the channel. Wall mounting Preparing Premium Reflexes terminals - Turn the terminal upside down. Ed. 02 Réf. 3EH21017BSAA 1/6
66 INSTALLING REFLEXES TERMINALS - Using a screwdriver, remove the two rubber studs from the top. Preparing Advanced Reflexes terminals - Turn the terminal upside down. - Using a screwdriver, remove only the left-hand rubber stud. Mounting the terminal - Use the mount as a drilling template and install the mount using the plugs and screws supplied. Terminal hanging lugs Mount for Reflexes Premium/ Advanced terminal Retaining lug - Hook the terminal onto the two lugs of the support: introduce these two lugs into the recesses previously occupied by the rubber studs (or left-hand stud and hole provided for this purpose, in the case of an Advanced Reflexes terminal). - Install the terminal on its mount by engaging the support lug in the bottom of the terminal. Mounting the optional module - Turn the terminal upside down. - Remove the cover at the rear of the terminal. - Slide the module into the terminal. - Connect the module to the terminal (connector ). - Attach the module to the terminal using the screw provided in the kit. - Connect the module cable (connector UA) to the terminal wall socket. 2/6 Réf. 3EH21017BSAA Ed. 02
67 File 7 INSTALLING REFLEXES TERMINALS Module output (to wall socket) Connection wiring between module and terminal UA Receiver cord Typical optional module application: connecting a pulse metering system To wall socket 15 m max. V24 Data rate: 9600 bits/s Format : 8N1 (8 significant bits, no parity, 1 stop bit) PULSE METERING SYSTEM (EliteCost, Printer) Advanced Reflexes with V24 option OV RD TD RTS CTS If the system does not accept RTS/ CTS signals, strap 7-8. Abbreviations used: - TD: Transmitting data - RD: Receiving data - RTS: Flow check output - CTS: Flow check input Adding an extension unit - Turn the terminal and unit upside down. - Connect the unit to the terminal. - Mount the unit on the terminal using the metal clamp and the four screws supplied in the kit. Ed. 02 Réf. 3EH21017BSAA 3/6
68 INSTALLING REFLEXES TERMINALS To other extension unit if necessary Line cable (to terminal wall socket) Metal flange Receiver cord 4/6 Réf. 3EH21017BSAA Ed. 02
69 File 7 INSTALLING REFLEXES TERMINALS REFLEXES FIRST AND EASY TERMINALS Installing the line cable - Turn the terminal upside down. - Plug in the line cable (connector ) and route it as shown in the figure. Installing the receiver cord - Turn the terminal upside down. - Plug in the receiver cord (connector ) and route it through the channel provided. Wall mounting Preparing the terminal - Turn the terminal upside down. - Unscrew A and remove the metal plate. - Reinstall this plate in the bottom groove and secure with screw B. - Extract the receiver hanging lug by turning the screw C through one half turn. Line cable (to wall socket) C screw A Metal plate B Receiver cord Channel Mounting the terminal - Drill two holes complying with the dimensions indicated below. - Position the mounting screws as shown below. - Mount the terminal. Ed. 02 Réf. 3EH21017BSAA 5/6
70 INSTALLING REFLEXES TERMINALS To p H2 Adjustment of attaching screws 143 mm H1 = 6 mm H2 = 6 mm - 1 turn of screw H1 Bottom Metal plate Mounting the optional module In the case of Reflexes First and Easy terminals, the optional module is external to the terminal. The module can stand on a table or be wall-mounted. The installation procedure in this case simply involves making the connection between the terminal, the module and the wall socket. Wall-mounting the optional module - Drill two holes (spacing = 105 mm, diameter = 6 mm). - Position the mounting screws. - Mount the module. 105 mm UA Module output (to wall socket) To Reflexes terminal (3 m max.) 6/6 Réf. 3EH21017BSAA Ed. 02
71 INSTALLING DECT BASE STATIONS INSTALLING DECT BASE STATIONS File 8 This sheet describes the rules to be applied for an installation comprising three or four DECT base stations. With larger installations, a prior study using coverage tools must be performed. The base stations are then installed in accordance with the results of this study. CONNECTION The 4070 IO base station is designed for internal installation in the building, while the 4070 EO base station is designed for external installation. A base station can be connected to 1 or 2 UA links (UAI boards) and allows for 3 or 6 simultaneous communications with DECT/GAP terminals. Whether three or six communication channels are required depends on the number of cordless terminals and the amount of DECT traffic to be managed. In the case of connection by two cables: - use two adjacent interfaces of a UAI board - use the even interface for the master link and the other interface for the slave link. The two cables must be of the same length. The first interface of the system UAI16 board must not be used, as the operator terminal uses these points. UAI-3 UAI-4 1 : L1 2 : L2 3 : L1 4 : L2 Distribution panel DIGITAL INTERFACES UAI Screw terminal block Ed. 02 Réf. 3EH21017BSAA 1/6
72 INSTALLING DECT BASE STATIONS NUMBER OF BASE STATIONS REQUIRED Radio signals are affected by various propagation phenomena: attenuation, reflection and diffraction. These phenomena are related to the environment of the Alcatel 4070 IO/EO base station and affect the system's radio performance. The effects can be favorable or detrimental to wave propagation. If we consider, for example, a building with a metal structure. In such a building, radio wave reflection will be considerable and system performance will be adversely affected. In addition, the range of the Alcatel 4070 IO/EO base station will be strongly dependent on the degree of attenuation of the radio waves as they pass through numerous partitions. The table below shows the overall area coverage (cell) values for an Alcatel 4070 IO/EO base station operating under normal environmental and topological conditions: Indoors Outdoors Coverage radius ~ 50 m ~ 400 m Area covered ~ m 2 ~ m 2 NUMBER OF USERS PER BASE STATION Type of base station connection Number of DECT users 3 channels 4 6 channels 12 2/6 Réf. 3EH21017BSAA Ed. 02
73 File 8 INSTALLING DECT BASE STATIONS POSITIONING OF DECT BASE STATIONS Certain environmental and infrastructure considerations should be taken into account when siting Alcatel 4070 IO/EO base stations: INDOOR COV- ERAGE OUTDOOR COVERAGE Positioning recommendations As far as possible from walls Do not mount the station directly on a metal structure Do not install in false ceilings or technical rooms Install as far as possible from industrial machinery or electrical cabinets Install the base stations in open spaces (as far from buildings as possible) Place the base stations above obstacles (trees, cars, etc.) Possible solutions Suspend the Alcatel 4070 IO/EO in a clear area Move the Alcatel 4070 IO/EO to another area Install the Alcatel 4070 IO/EO in favorable areas (corridors) Install the Alcatel 4070 IO/EO in favorable areas Install on pylons, for example On the top of buildings or on pylons, for example Ed. 02 Réf. 3EH21017BSAA 3/6
74 INSTALLING DECT BASE STATIONS ENVIRONMENTAL PROTECTION For outdoor installations, protection must be provided against lightning strikes, and this will depend on the positioning of the Alcatel 4070 IO/EO base station. Conditions requiring protection against lightning strikes The Alcatel 4070 IO/EO base station must be protected against lightning strikes when it: - is situated less than 1.5 m from a wall and more than 2 m below the antenna, - uses an outdoor overhead line connection between the base station and the system. INSTALLATION RECOMMENDATIONS Normal topology Building structures can have three basic shapes: ROUND coverage zones RECTANGULAR coverage zones ROUND coverage zones The distances indicated above give some idea of the approximate range of a radio base station. The comparison clearly shows that rectangular zones require more base stations to achieve the same coverage. Installation considerations In multi-floor buildings, various solutions must be envisaged, depending on: - the coverage obtained at each level. - the location of the Alcatel 4070 IO/EO base station (upper or lower floor). 4/6 Réf. 3EH21017BSAA Ed. 02
75 File 8 INSTALLING DECT BASE STATIONS Installation examples Square zone Rectangular zone st 1 1 floor terminals nd 2 2 floor terminals Example 1: square building Example 2: rectangular building 1 st floor 1 st floor 2nd floor 2 nd floor In this type of building it is possible to alternate the number of base stations used from one floor to the next. The technique is to alternate base station positioning from one floor to the next. This technique can be applied on every other floor, if a floor can be covered by the base stations on the adjacent floor. Ed. 02 Réf. 3EH21017BSAA 5/6
76 INSTALLING DECT BASE STATIONS Infrastructure-dependent coverage Description: st 1 floor: 66m x 42 m (1) offices (2) corridors (3) lifts (4) stairs 2 floors to cover The proposed solution is to install two relay units per floor, with the positioning alternating from one floor to the next. The solid-line circles show the zones covered by each relay unit (B1, B2, B3, B4). The shaded zones represent the predicted coverage on one floor provided by the relay unit installed on the floor above or below. 6/6 Réf. 3EH21017BSAA Ed. 02
77 INSTALLING FAST IP REFLEXES TERMINALS INSTALLING FAST IP REFLEXES TERMINALS File 9 CONNECTION Fast IP Reflexes terminals are connected through a 4098 FRE IP Enabler option. IP ENABLER 4098 FRE MAINS POWER UA LAN PC LAN PC LAN CPU CONFIGURATION Depending on the network typology, the configuring of the Fast IP Reflexes terminals can be: - fully automatic, if they are on the same subnet as Alcatel OmniPCX Office: simply connect the terminals to the LAN and then connect the power supply unit. The DHCP server allocates the dynamic IP addresses and the TFTP server built into the CPU/CPUe board downloads the software into the IP Enabler. - manual, when the terminals are connected to a different Alcatel OmniPCX Office subnet, or if the DHCP server integrated in the CoCPU VoIP board is deactivated: in this case the IP parameters and the TFTP server address must be entered on the devices. Registering Fast IP Reflexes terminals connected to a subnet other than Alcatel OmniPCX Office - Connect the power supply on the relevant Fast IP Reflexes terminal - Press i then # - Press 2 (IP Parameters) - Press 1 (Dynamic Mode) - Press 2 (IP Address) Ed. 02 Réf. 3EH21017BSAA 1/2
78 INSTALLING FAST IP REFLEXES TERMINALS - Enter the IP address of the terminal - Confirm by pressing # - Press 3 (Subnet Mask) - Enter the IP address for the subnet mask of the CoCPU VoIP board - Confirm by pressing # - Press 4 (Router Address) - Enter the IP address of the external router - Confirm by pressing # - Press 5 (TFTP Server) - Enter the IP address of the CoCPU VoIP board - Confirm by pressing # - Press End (NB: option 6 (Main CPU Address) is not used). - Press # to save; the terminal displays two screens in succession: Modification Saved and IPPhone will reset before resetting itself. The Fast IP Reflexes terminal will perform six registration phases at startup: - Phase 1: IP initialization - Phase 2: Downloading of the configuration file - Phase 3: Downloading of the binary file - Phase 4: Flashing of the binary - Phase 5: Downloading of the startup file - Phase 6: Establishing of IP signaling At the end of phase 6, the terminal is initialized and appears in the list of PM5 terminals. The use of Fast IP Reflexes terminals requires a degree of system configuration by PM5, specifically: - number of VoIP subscriber channels - activation / deactivation of the DHCP server (dynamic allocation or manual entry of IP addresses) Consult the Voice over IP section of the product technical documentation for further details. 2/2 Réf. 3EH21017BSAA Ed. 02
79 INSTALLING CLIENT PCS INSTALLING CLIENT PCs File 10 To access the Internet from a client terminal, the network configuration and Internet explorer configuration have to be modified. The client PC must be equipped with a web browser(netscape Navigator or Internet Explorer version 4 or later). CONFIGURING THE NETWORK Enter the IP address of the CoCPU@ board as the default gateway. Consult the documentation of the operating system used on the client terminal for further details. Exemple : Configuring a Windows 98 station - Right-click the Network Neighborhood icon in the Windows desktop. - Select the Properties option in the context menu. The Network window is displayed. - Double click on the TCP/IP topic. A new window appears: TCP/IP properties. - Click the Gateway tab. - Enter the IP address of the CoCPU@ board in the New Gateway topic. - Click Add, then OK. - Restart the computer for the modification to take effect. CONFIGURING THE WEB BROWSER For a simple Internet access, configure the web browser to send requests directly without passing via a proxy server. For further details, consult the relevant web browser documentation. Exemple : Configuring Internet Explorer Version Select the Internet Options... topic in the Tools menu. - Click the Connections tab. - Click the LAN Parameters button in the Internet Options window. - Configure the Local Area Network (LAN) Settings window as indicated below, and confirm by Ed. 02 Réf. 3EH21017BSAA 1/2
80 INSTALLING CLIENT PCS clicking OK. 2/2 Réf. 3EH21017BSAA Ed. 02
81 DEFAULT CONFIGURATION DEFAULT CONFIGURATION File 11 REFLEXES TERMINAL PROFILES - The first Reflexes terminal (extension 100) is the Operator station. This Reflexes Advanced terminal is included in all active operator station (Attendant) groups and the standby Attendant group. - The second terminal is a Secretary terminal and the third is a Manager terminal. - Only Reflexes Advanced or Premium terminals support the Manager/Secretary facility. The meanings of the symbols are explained below Redial Conference Automatic call-back Transfer Message Diversion Directory Next screen Call pickup Cancellation of 2 nd call-back Ed. 02 Réf. 3EH21017BSAA 1/4
82 DEFAULT CONFIGURATION Reflexes First terminal profile A Reflexes First terminal operates in single-line mode. Reflexes Easy terminal profile A Reflexes Easy terminal cannot be used as an Operator (Attendant), Manager or Secretary terminal. Reflexes Premium terminal profile Key system mode Operator Terminal Manager Terminal Secretary Terminal Normal Terminal Trunk 1 Trunk 2 Trunk 1 Trunk 2 Trunk 1 Trunk 2 Trunk 1 Trunk 2 Trunk 3 AttDiv Trunk 3 Secrtr Trunk 3 Managr Trunk 3 Trunk 4 Trunk 4 Trunk 4 ScrMgr Trunk 4 ScrMgr Trunk 5 Trunk 6 PABX mode Differences in relation to key system mode: - The first two line keys are replaced by CalExt keys (outside line obtained by dialing 0). - The other line keys are replaced by unassigned keys. You can program these for an internal extension (terminal) or an external number (preceded by the outside line prefix). 2/4 Réf. 3EH21017BSAA Ed. 02
83 File 11 DEFAULT CONFIGURATION Line key programming procedure: Key to be programmed Reflexes Advanced terminal profile Key system mode Clear Erase previous key assignment if necessary OK Confirm The terminal returns to inactive Operator Terminal Manager Terminal Trunk 11 Trunk 12 Trunk 11 Trunk 12 Trunk 1 Trunk 2 Trunk 13 Trunk 14 Trunk 1 Trunk 2 Trunk 13 Trunk 14 Trunk 3 Trunk 4 Trunk 15 AttDiv Trunk 3 Trunk 4 Trunk 15 Secrtr Trunk 5 Trunk 6 Normal/Restr Trunk 5 Trunk 6 ScrMgr Trunk 7 Trunk 8 Trunk 7 Trunk 8 Trunk 9 Trunk 10 Trunk 9 Trunk 10 Secretary Terminal Normal Terminal Trunk 11 Trunk 12 Trunk 11 Trunk 12 Trunk 1 Trunk 2 Trunk 13 Trunk 14 Trunk 1 Trunk 2 Trunk 13 Trunk 14 Trunk 3 Trunk 4 Trunk 15 Managr Trunk 3 Trunk 4 Trunk 15 Trunk 16 Trunk 5 Trunk 6 ScrMgr Trunk 5 Trunk 6 Call Trunk 7 Trunk 8 Trunk 7 Trunk 8 Trunk 9 Trunk 10 Trunk 9 Trunk 10 PABX mode The differences in relation to key system mode are the same as for a Reflexes Premium terminal (see previous page). OTHER PREDEFINED DATA - Level 1 dynamic routing of terminals: all calls are routed to recorded message mailboxes after ringing for 12 seconds unanswered. - Level 2 dynamic routing of terminals: outside calls only are routed to the Attendant group after ringing for 24 seconds unanswered. - Calls to the operator station overflow to the general level (backup Attendant group) after Ed. 02 Réf. 3EH21017BSAA 3/4
84 DEFAULT CONFIGURATION ringing for 24 seconds unanswered. - The backup Attendant group contains the first 2 ports of the integrated voice server, the general bell, remote XRA access and the first Reflexes (Operator Station) interface. - All the terminals (except the analog terminals) are assigned a voice mailbox. - The first analog interface is a fax. 4/4 Réf. 3EH21017BSAA Ed. 02
85 STARTING UP THE SYSTEM FROM AN ADVANCED TERMINAL STARTING UP THE SYSTEM FROM AN ADVANCED TERMINAL File 12 The startup session provides a simple means of configuring all the data you need for optimum operation of your system. The startup session is proposed automatically, after the first system power-up. To set up the system properly, you should have the following information available: - The telephone number of your system (international country prefix, national prefix, etc.). - The value of the basic metering unit. - the ranges of numbers assigned by the network operator to the direct public network (DDI) numbers for the terminals in your system. GENERAL SOFT KEYS Prev Return to previous menu. Next Go to next menu. Rubout Erase last character. Cancl Cancel. Change Go to another of the proposed options. OK Confirm an entry. Movement of the cursor. Browser for selecting the upper or lower line onthe Reflexes Advanced terminal display; also enables left and right scrolling. Ed. 02 Réf. 3EH21017BSAA 1/8
86 STARTING UP THE SYSTEM FROM AN ADVANCED TERMINAL FIRST POWER-UP System operation mode: Business "Define the basic system configuration" is displayed Go on Change Next Restarting the session during programming. Custom Restarting the session after using the Exit function to quit SYSTEM TYPE System operation mode: Business Change Next Change Defines system type: Business or Hotel. INSTALLATION NUMBER Public Netw Nbr: 33** Prev Rubout Split N ext This number must be entered and must be complete. The installation number can contain up to three fields, for a maximum overall total of 16 characters. Split Fields are separated by an asterisk. The various possible fields are: - International prefix of the country (for example: 44 for Britain): obligatory field. - National prefix: optional field (N/A for national calls). - Public installation number: obligatory field. 2/8 Réf. 3EH21017BSAA Ed. 02
87 File 12 STARTING UP THE SYSTEM FROM AN ADVANCED TERMINAL NUMBERING PLAN 3-digits internal numbering plan Prev Change N ext Change Used to select the system internal numbering plan (terminal numbers: 2 to 4 digits, national or *). Changing the numbering plan erases the existing DDI numbers. TERMINAL DDI NUMBERS This function is used to define the DDI (Direct Dialing Inward) numbers of all the terminals in a Business system and the Administrative (Reflexes) terminals in a Hotel system. Only one DDI number can be assigned to each internal extension number. Define public extension numbers Prev Change N ext Change To define the terminal DDI numbers; display of the 1st internal extension/ddi number. Internal N: 100 Public Ext: 100 Cancel Down Clear Up OkAll The number contains up to 4 digits and can be changed (the cursor is positioned at the beginning of the field). The DDI numbers are usually the last 3 or 4 digits of your line numbers. The telephone company informs you of the range of numbers assigned to you. Low or Up Scroll the list of internal extension numbers and validate the displayed entry. Clear Cancl OK All Delete the digits contained in the "Public Ext" field. Reject the complete list of DDI numbers as defined and return to the start of the function. Validate the complete list of DDI numbers. Ed. 02 Réf. 3EH21017BSAA 3/8
88 STARTING UP THE SYSTEM FROM AN ADVANCED TERMINAL The following error messages may be displayed during data entry: - "Extension number already used": the DDI number defined is already assigned to another extension. - "Extension number out of range": invalid DDI number (for example, it may contain a * or # character). - "List of public extensions full": public numbers table overflow (99 entries). The following function is only available in a Hotel system. Define guests public extension nbrs Prev Change Next Change Define DDI number pool. Display the 1st DDI number. Pool Entry: 1/99 Public Ext: 10 Cancel Down Clear Up OkAll 10: Quantity of numbers still available in the DDI table after defining the direct call numbers In a Hotel system, all Z terminals are used as room extensions (except the first, which is a fax, and the second, which is a callbox). The pool of DDI numbers allows a DDI number to be dynamically assigned to these extensions when a customer checks in. The number of DDI numbers available will depend on how many are used for staff extensions (a total of 99 numbers are available in the system public numbers table). The display indicates the table position of the selected entry and the number of entries available. Low or Up Scroll the pool of DDI numbers and validate the displayed entry. Clear Cancl OK All Delete the digits contained in the "Public Ext" field. Reject the complete list of DDI numbers as defined and return to the start of the function. Validate the complete list of DDI numbers. 4/8 Réf. 3EH21017BSAA Ed. 02
89 File 12 STARTING UP THE SYSTEM FROM AN ADVANCED TERMINAL NUMBER OF LINES CONNECTED TO THE PUBLIC NETWORK Number of Trunks to Public Network: 00 Prev Rubout N ext This function is used to indicate the number of lines or B-channels connected to the public network (max. 120 lines or 120 B-channels). These lines are then included in the main trunk group (following the board acceptance sequence) and are indicated by resource keys. On the operator station, a T2 access can contain up to 30 B-channels; a T1 access up to 23 B-channels; a T0 access up to 2 B-channels. The message "Number exceeds equipped boards" is displayed if the value entered exceeds the number of equipped B-channels. OPERATING MODE OF USER TERMINALS AND OPERATOR STATIONS Subscriber terminals: PBX mode Prev Change N ext This function is only available in a business system (in a hotel, only the PBX mode is used). Change "PBX mode" and "Key system mode". PBX mode: all the lines are represented by 2 RSB keys (resource keys dedicated to a trunk group). Key system mode: the terminal has as many RSP keys (resource keys dedicated to an external access) as there are lines in the system. See "Default Configuration " in this manual for an account of the function of the various keys on each type of terminal, depending on the selected operating mode. Operator terminals: Key system mode Prev Change N ext ARI NUMBER Access Right ID: Prev Rubout Next Ed. 02 Réf. 3EH21017BSAA 5/8
90 STARTING UP THE SYSTEM FROM AN ADVANCED TERMINAL This function is only available if your system has a DECT facility The ARI (Access Right Identifier) number identifies the system uniquely to mobiles. It consists of 11 octal (base-8) digits (values from 0 to 7). The number, keyed in on an ETSI base by the installer, should be entered as soon as the system is installed. The first digit cannot be modified and always takes the value 1. The cursor is positioned automatically on the second digit. The last digit always takes the value 0 or 4. USER INFORMATION LANGUAGE Terminal language: English Prev Change N ext Change Select the language used on all the system terminals (display and voice guides) BASIC PULSE METERING RATE Charge rate per unit: Prev Rubout N ext The value of the basic pulse metering rate is entered in order to calculate the cost of outside calls. In this case, the cost (not the duration) and the progress of the meter readings during the call are displayed. The value entered can comprise 5 digits (including 0 to 2 decimal places) in the selected currency. This service requires a specific subscription with the telephone company. Nota : Duration metering requires a third-party application. DATE AND TIME Date : 01/01/2000 Time: 00:00 Prev Rubout N ext It is obligatory to enter the date and time. Enter the date in the format DD/MM/YYYY and the time in the format HH/MM. The message "Date and time must be set" is displayed if the "Date" and "Time" fields are blank or contain default values. 6/8 Réf. 3EH21017BSAA Ed. 02
91 File 12 STARTING UP THE SYSTEM FROM AN ADVANCED TERMINAL SYSTEM RESET This menu is proposed for confirming the system reset. Restart the system in new configuration? Prev Finish Finish System reset; the display indicates "System restart in progress". After this reset phase, your system operates with the data newly entered. Ed. 02 Réf. 3EH21017BSAA 7/8
92 STARTING UP THE SYSTEM FROM AN ADVANCED TERMINAL 8/8 Réf. 3EH21017BSAA Ed. 02
93 STARTING UP THE SYSTEM WITH PM5 STARTING UP THE SYSTEM WITH PM5 File 13 PRESENTATION PM5 is the PC application used to program the Alcatel OmniPCX Office system via a local connection (V24 or LAN), or a remote connection (the PC modem is connected to the built-in Alcatel OmniPCX Office modem via a public network). PM5 provides three programming levels: - Easy View provides for Wizard configurations, i.e. the parameters vital for starting up the system. - EasyPlus View provides for Wizard configurations with extended possibilities offered by the Advanced key. This key opens a window equivalent to Expert View. - Expert View gives unrestricted access to all the configuration possibilities. The Wizard functions provide a user-friendly system programming facility that guides the user through each step. The Internet Access functions are configure d with the Wizard by entering the IP address of the CoCPU@ board in the PC navigator. MINIMUM PC CONFIGURATION - Pentium 166 MHz processor. - RAM: 32 MB for Windows 95, 98 and 2000; 64 MB for Windows NT. - Hard disk. - Screen: 800 x 600 pixels. - 1 mouse. - 1 serial port (connection to Alcatel OmniPCX Office for data transfer). - 1 Ethernet board (IP mode). - Operating system: Windows 95, 98, 2000 or NT4, pack 5 minimum. - 64K PPP-compatible ISDN or V34 modem for remote access. - Network board. Ed. 02 Réf. 3EH21017BSAA 1/8
94 STARTING UP THE SYSTEM WITH PM5 To use the serial port or a modem, the Remote Access Service (RAS) must be installed on the PC. It can be found on the operating system software CD. Installing RAS in Windows NT4 - Open the control panel. - Open the Network folder. - Select the Services tab. - Click Add. - Select Remote access service from the list. - On the NT prompt, open the modem installation program. - Check the Don't detect my modem... box and click Next. - In the list of modems, select the Dial-up networking serial cable modem. - When installation is completed, restart the PC. TYPES OF CONNECTION Local connection Distribution panel PROCESSING UNIT CPU LAN AUDIO-OUT CONFIG LAN FAN POWER MODULE 1 MODULE 2 AUDIO-IN DOORPHONE MODULE CPU OR PC - Local connection by LAN When connected to the LAN port on the CPU/CPUe board via a UTP Category Ohm crossover cable, or to the switch on which the CPU/CPUe board is connected via a straight cable, the default IP address for the main CPU/CPUe board is The PC IP address and network mask must be compatible with the address of Alcatel OmniPCX Office; for example: and /8 Réf. 3EH21017BSAA Ed. 02
95 File 13 STARTING UP THE SYSTEM WITH PM5 - Local connection by V24 The connection is made using an RJ45 - SUB D 9 point female cable between the CONFIG connector on the CPU/CPUe board and the PC serial port. Wiring of the connection cable: RJ SUB D 9-point (F) During the first run, after launching PM5: Select the Comm menu and then Connector. Click Local then start the NT Modem Wizard. Select Don't detect. In the list of makers, select Alcatel and in models, select OmniPCX Direct V24. In the next screen, select the COM port and click Finish. Close the modem window. - Then select OmniPCX Direct V24 created. In subsequent sessions, all you have to do to get connected is to select Local then OK in the Communication screen. Remote connection - Remote connection by ISDN modem The ISDN modem must support 64K PPP. Follow the instructions in the installation manual supplied with the modem. Once installed, configure the modem for RAS. To use it, simply select Modem Direct and click OK. - Remote connection by analog V34 modem The modem must be V34 compatible. The installation and utilization procedures are the same as for the ISDN modem. Ed. 02 Réf. 3EH21017BSAA 3/8
96 STARTING UP THE SYSTEM WITH PM5 INSTALLING THE PM5 SOFTWARE The PM5 software is installed from a CD-ROM. The application is installed by making selections from the options proposed in the various windows. When installation is completed, you access the application by double-clicking on the new icon created on the Windows desktop. - Select Start then Program then Alcatel OmniPCX Office then PM5. - The window Welcome to PM5 appears. PM5 FEATURES Access to modes 2, 3 and 4 is protected by a password: pbxk DATA COLLECTION AND TOOLS This mode is used to create.crp files (client collective speed dial files) off-line, for use in the Installation Typical menu. 2 - INSTALLATION TYPICAL This mode enables manual on-line programming by choosing between Business and Hotel and automatic on-line programming using.crp files. Nota : The Business/Hotel choice is only proposed once. To obtain the choice again, you have to perform a cold reset. Initial Installation Wizard (Business) - Default numbering plans - Installation number. - Operation mode - Channels and trunk groups - DECT ARI - Creation of DECT terminals - Pulse metering - Date and time - List of subscribers - Misc. subscribers - Collective speed dial numbers - Attendant groups - Hunting groups - Broadcast groups - Pickup groups - Screening 4/8 Réf. 3EH21017BSAA Ed. 02
97 File 13 STARTING UP THE SYSTEM WITH PM5 Initial Installation Wizard (Hotel) In addition to the Business possibilities, this Wizard configures the room extension numbers. Installation Wizard This Wizard uses.crp files created in Data Collection and Tools -> Wizard for Data Collection Follow the instructions; at the end, if the settings are accepted, the data are transmitted to the system, which then reboots. 3 - MODIFICATION TYPICAL The 5 icons in this mode (Subscribers, Groups, System, Collective Speed Dialing and External Access) call up Wizards for the straightforward modification or configuration of a range of parameters, as detailed below. The data are registered in the system by clicking OK. Subscribers - List of subscribers: public network number, name, barring level, accessible trunk groups. - Call distribution in normal and restricted mode. - EasyPlus View: detailed parameters for each subscriber: keys, languages, authorized operation, personal code, diversions, dynamic routing, personal directory, etc. Groups Attendant groups - Composition: entry of the members of each group. - Assigning a welcome message to each group. Hunting groups - Name and type (parallel, cyclic or sequential). - Composition: entry of the members of each group. - Assigning a welcome message to each group. Broadcast groups - Name of each group. - Composition: entry of the members of each group. Ed. 02 Réf. 3EH21017BSAA 5/8
98 STARTING UP THE SYSTEM WITH PM5 Call pickup groups - Composition: entry of the members of each group. Collective Speed Dialing - For each entry: name and number of called party. System Default numbering plans - Choice between national numbering plans or star numbering plans with 2, 3 or 4 digits. - EasyPlus View: Normal mode public network numbering plan. - EasyPlus View: Restricted mode public network numbering plan. - EasyPlus View: Features in conversation. - EasyPlus View: Internal numbering plan. Installation numbers - International code. - Intercity code. - Installation number. - EasyPlus View: Callback prefix. - EasyPlus View: Personalized caller's number. - EasyPlus View: Private installation number. Pulse metering - Cost of telephone metering. - EasyPlus View: Hotel pulse metering for the standard currency unit (VAT, prepaid sum, etc.) - EasyPlus View: Pulse metering options for the standard currency unit. - EasyPlus View: Print settings. - EasyPlus View: Pulse metering options for the replacement currency unit (Euro). Date and time Software keys - System key. 6/8 Réf. 3EH21017BSAA Ed. 02
99 File 13 STARTING UP THE SYSTEM WITH PM5 - CTI key. External access - B-channel number. - Outside number for incoming calls (DISA). - Dialing type. 4 - EXPERT This mode authorizes all possible system maintenance and modification operations. The Wizards proposed in modes 2 and 3 are also available. Ed. 02 Réf. 3EH21017BSAA 7/8
100 STARTING UP THE SYSTEM WITH PM5 8/8 Réf. 3EH21017BSAA Ed. 02
101 INSTALLATION OF AN INTERNET ACCESS INSTALLATION OF AN INTERNET ACCESS File 14 To take advantage of the shared Internet access on a client terminal, several steps have to be undertaken: - Connect the Alcatel OmniPCX Office system to the existing LAN or via the integrated LAN (LANX8 or LANX16 board). - Creation and configuration of an Internet connection. - Configuration of the client terminal INSTALLING THE ALCATEL OMNIPCX OFFICE SYSTEM - CONNECTING TO THE LAN Hardware required on Alcatel OmniPCX Office - a CPUe card (Internet access only) or a CoCPU@ card (Internet access + Proxy, E mail, etc...), in the case of an ISDN connection. In the case of an ADSL or LAN to LAN routing connection, a CoCPU@ card fitted with a 2nd Ethernet interface is added. - an ISDN T0 or T2 connection in the case of Internet access via ISDN. - a client terminal connected to the LAN. - a LAN switch (LANX8, LAN X16 or external switch). Items required on the client terminal - the latest version of the PM5 software. - an Internet navigator (Netscape Navigator or Internet Explorer version 4 or higher). Installation procedure 1. Connect the CPU card using an Ethernet cable: either to an RJ45 jack available on the company's LAN. - or to the internal switch in the Alcatel OmniPCX Office cabinet. This switch can then be connected to another switch if Alcatel OmniPCX Office has several switches. Ed. 02 Réf. 3EH21017BSAA 1/10
102 INSTALLATION OF AN INTERNET ACCESS 2. If necessary, change the default IP addresses ( for CPUe, for and the mask of the sub-network to IP addresses that are compatible with the existing LAN (for more information, contact the company's network and system administrator). The IP addresses of the different cards can be accessed through the heading PM5 -> PABX Client -> Hardware and limits-> IP cards. 3. Internet access configuration: either via the Internet navigator of a customer terminal connected to the LAN by entering the IP address of the CPU Main or CoCPU@ card in the address bar. - or via the PM5 software, from the PM5 -> PABX Client -> Internet access configuration menu. Subscription to the Internet access provider (IAP) A subscription with an IAP is necessary to access the Internet.. After you have subscribed, the IAP sends you back the information vital for installing you Internet access. This information must be entered when configuring Alcatel OmniPCX Office. ISDN type connection Parameters Definitions Connection account IP addresses of the primary and secondary DNS server Type of connection IP address allocation Telephone number Bandwidth Account used during connection to the access service provider. this is a unique account that is used to identify you when connecting. The login and an associated password are provided. They correspond to the IP addresses of the DNS servers used by the access service provider (DNS is optional item of data that can be negotiated during connection). The type of link between Alcatel OmniPCX Office and the access supplier can be established as "On-demand call", as "Permanent" or as "Callback". The IP address is allocated to Alcatel OmniPCX Office by the access provider. This address is public. The access provider manages or does not manage IP address negotiation. Call number of the Internet service provider. This is the number dialed when an ISDN type connection is requested. The speed of this connection must be 64 or 128 Kbps. it must be an ISDN type connection. 2/10 Réf. 3EH21017BSAA Ed. 02
103 File 14 INSTALLATION OF AN INTERNET ACCESS Connection of a DSL type modem Parameters Connection account IP addresses of the primary and secondary DNS server IP address allocation Connection protocol Connection property Definitions Account used during connection to the access service provider. this is a unique account that is used to identify you when connecting. The login and an associated password are provided. They correspond to the IP addresses of the DNS servers used by the access service provider (DNS is optional item of data that can be negotiated during connection). The IP address is allocated to Alcatel OmniPCX Office by the access provider. This address is public. The access provider manages or does not manage IP address negotiation. This information is provided by the IAP for a connection using a DSL modem. Two types of communication protocols are available to manage this connection: PPPoE or PPTP. To define the connection parameters, the IAP gives the following elements: address of the DSL modem, network mask and IP address of the system. LAN to LAN Routing type connection Parameters Definitions IP addresses of the primary and secondary DNS server Connection property IP addresses of the DNS servers used by the access provider (DNS is an optional item of data that can be negotiated during connection) if the IAP gives it, or if this is the case, the IP addresses of the external router. To define the connection parameters, the IAP gives the following elements: address of the Router, network mask and IP address of the system. Ed. 02 Réf. 3EH21017BSAA 3/10
104 INSTALLATION OF AN INTERNET ACCESS CREATING AND CONFIGURING AN INTERNET CONNECTION. An Internet connection is created using the Internet Wizard. To configure a connection, apply the following procedure. 1. Click on Assistants then on Internet Access. 2. Enter the following parameters: IAP profile name: this name identifies the new Internet connection managed by Alcatel OmniPCX Office. It holds all the parameters linked to this connection. It is recommended that a name that is representative of the created connection is entered, such as the name of the access provider. - Type: this field is used to define the type of connection. Alcatel OmniPCX Office provides three types of connection to access the Internet: ISDN, DSL modem or LAN to LAN Routing 3. Click on Next to display the IAP Configuration screen. Configuration of an ISDN connection 1. Enter the following parameters in the IAP configurationscreen. Login: connection account given by the service provider. Password: password given by the service provider. Confirm Password : enter password again. This confirmation step is used to verify that the password entered is correct. - Main Number : local telephone number given in the subscription. This number must include the external line prefix. Callback: to take account of barring, traffic distribution mechanisms, etc. 2. Click on Next to display the Access configuration screen. 3. Enter the following parameters: ISDN B Channel management: - 1 B channel (64 Kbps): this option is selected if the data rate of the subscription is 64 Kbps. - on demand ( Kbps): this option is selected if the data rate of the subscription is 128 Kbps, and provides dynamic use of the B channels. This option is used to allocate one or two B channels to meet traffic needs, and to reduce telephone costs by not using the two B channels permanently. 4/10 Réf. 3EH21017BSAA Ed. 02
105 File 14 INSTALLATION OF AN INTERNET ACCESS - two B channels (128 Kbps): this option is chosen if the data rate of the subscription is 128 Kbps, and for the permanent static use of two B channels. The charges generated by using this option correspond to two telephone calls. ISDN connection: - On demand: this option is selected to make a connection according to user connection demands. The connection with the service provider is established on demand and automatically terminated when there is no more traffic over the ISDN link. - Permanent: this option is selected in order to have a permanent connection with the service provider. Consequently, the call to the service provider is permanent. - Callback: this option is selected when using VPN. Consequently, it is not recommended for Internet access use only. 4. Click on Next to display the Internet configuration screen. 5. Enter the following parameters: IP address: public IP address assigned to OmniPCX Office. - Dynamic: this option is selected if an IP address is assigned to each connection by the service provider. - Fixed: this option is selected if a fixed IP address is assigned to OmniPCX Office. This address is then provided with the service provider's subscription. The fixed IP address is needed to install other functions, but is not necessary for a simple Internet access. Domain Name Server: - Dynamic: this option is checked if the DNS resolution is set automatically when connection is established. - Fixed: enter the IP address of the service provider's primary DNS server if the option is selected. 6. Click on Next to access the Summaryscreen. 7. Click on Apply to accept these parameters and enable the profile. Click on Back to return to the previous screens and modify the desired parameters. This stage is used to verify the connection properties. A connection test is possible, and can be done by clicking on Test the connection after accepting the configuration. The test runs all the steps involved in connecting to a service provider, and indicates the causes of any problems and the corresponding solutions in the event of failure. Configuration of a DSL modem connection 1. Enter the following parameters in the IAP configurationscreen. Ed. 02 Réf. 3EH21017BSAA 5/10
106 INSTALLATION OF AN INTERNET ACCESS Login: connection account given by the service provider. Password: password given by the service provider. - Confirm Password : enter password again. This confirmation step is used to verify that the password entered is correct. 2. Click on Next to display the Access configuration screen. 3. Choose the type of connection Over Ethernet Protocol (PPPoE) option Choose on Demand if your access is not permanent. Click on Next to display the Internet configuration screen. Enter the following parameters: Allocation of IP address: two choices are possible: - if the IAP gives an IP address, enter it in the fixedfield - Otherwise select the dynamic option. Primary DNS server: two choices are possible: - Check the Dynamic option if the resolution of the DNS is automatic during connection. - Enter the IP address of the access provider's primary DNS. It is recommended that recognition of the IAP's DNS is left at automatic. Click on Next to access the Summaryscreen. Click on Apply to accept these parameters and enable the profile. Click on Back to return to the previous screens and modify the desired parameters. A connection test is possible, and can be done by clicking on Test the connection after accepting the configuration. The test runs all the steps involved in connecting to a service provider, and indicates the causes of any problems and the corresponding solutions in the event of failure. Tunelling Protocol (PPTP)option Click on Next to display the Access configuration screen. Enter the following parameters: - DSL Modem IP address: enter the IP address of the external modem. - System IP address: enter the IP address of the WAN interface. - Network mask: enter the defined mask. Click on Next to access the Summaryscreen. Click on Apply to accept these parameters and enable the profile. Click on Back to return to the previous screens and modify the desired parameters. 6/10 Réf. 3EH21017BSAA Ed. 02
107 File 14 INSTALLATION OF AN INTERNET ACCESS A connection test is possible, and can be done by clicking on Test the connection after accepting the configuration. The test runs all the steps involved in connecting to a service provider, and indicates the causes of any problems and the corresponding solutions in the event of failure. Configuration of a LAN to LAN routing connection 1. Click on Next to display the Connection configuration screen. 2. Enter the following parameters: Router address: enter the IP address of the external router. - Network mask: enter the mask provided. 3. Click on Next to display the Internet Settings screen. 4. Enter the following parameters: System IP address: enter the IP address of the WAN interface. Primary DNS: Enter the IP address of the access provider's primary DNS. - Secondary DNS: Enter the IP address of the access provider's secondary DNS. 5. Click on Next to access the Summaryscreen. 6. Click on Apply to accept these parameters and enable the profile. Click on Back to return to the previous screens and modify the desired parameters. This stage is used to verify the connection properties. A connection test is possible, and can be done by clicking on Test the connection after accepting the configuration. The test runs all the steps involved in connecting to a service provider, and indicates the causes of any problems and the corresponding solutions in the event of failure. CLIENT TERMINAL CONFIGURATION The client terminal needs to be configured in order to use Alcatel OmniPCX Office's shared Internet Access The changes must be made to the network configuration (TCP/IP configuration ), and to Internet navigator. Configuration varies depending on whether or not a proxy is used to access the Internet. with proxy You must configure the Internet navigator using the settings of the proxy. in contrast, it is not vital to enter the default gateway of the client terminal. Ed. 02 Réf. 3EH21017BSAA 7/10
108 INSTALLATION OF AN INTERNET ACCESS Without proxy You must enter the default gateway of the client terminal (enter the IP address of the ; in contrast, there is no need to configure the Internet navigator using the proxy settings. TCP/IP configuration Alcatel OmniPCX Office is a routing element between LAN and Internet. Alcatel OmniPCX Office needs to be configured as the default gateway on the client terminal to access the Internet. Exemple : configuration of a Windows 98 client terminal - Click on the Network neighbourhood icon, and choose the Properties option from the context menu. - In the Network window, double-click the TCP/IP icon under the Configuration tab. - Enter Alcatel OmniPCX Office's IP address in the New gateway field (Tab Gateway of the TCP/ IP propertieswindow). - Click on Add then shut the windows by clicking OK. - Re-boot the client terminal to have the changes take effect. Nota : This configuration is valid only if Alcatel OmniPCX Office is the main router in relation to the client terminal. In the case of other network configurations, contact the company's system administrator. 8/10 Réf. 3EH21017BSAA Ed. 02
109 File 14 INSTALLATION OF AN INTERNET ACCESS Configuring the Internet navigator The Internet navigator must be configured to take account of the existing LAN. Exemple : configuring Internet Explorer Run an Internet Explorer session. - Choose the Internet options...heading from the Tools menu. - Click on the Connections tab of the Internet options window. - Click on LAN settings... - Change the options in the Local network (LAN) settings window. - Click on OK to accept the changes. Nota : If the proxy server is active on Alcatel OmniPCX Office, enter the IP address of the CoCPU@ card, otherwise enter the IP address of the client's proxy server. Ed. 02 Réf. 3EH21017BSAA 9/10
110 INSTALLATION OF AN INTERNET ACCESS 10/10 Réf. 3EH21017BSAA Ed. 02
111 UPGRADING YOUR SYSTEM UPGRADING YOUR SYSTEM File 15 REPLACING A TERMINAL You can replace your Reflexes terminal by connecting another terminal of the same family, but of a different type, to your telephone socket. This replacement can be temporary or permanent. Replacing an analog terminal by another analog terminal, or replacing a Reflexes terminal by another of the same type, does not require any special procedure (just a simple hardware exchange). Temporary replacement The replacement terminal keeps the basic functions (customization is not transferred). The data that are not transferred are saved by the Alcatel OmniPCX Office until a terminal of the same type as the initial terminal is connected. Your terminal is unserviceable Your terminal is repaired Unplug Plug in Unplug Plug in Defective terminal Replacement terminal Replacement terminal Repaired terminal Permanent replacement A maximum amount of data is transferred from the initial terminal to the replacement terminal. Nontransferred data are erased. Unplug Plug in "Terminal replacement" code + password Defective terminal Replacement terminal Ed. 02 Réf. 3EH21017BSAA 1/10
112 UPGRADING YOUR SYSTEM Data conserved following the temporary or permanent replacement of a terminal - Service categories (supervised systems). - Barring criteria. - Metering data. - Messages and list of recent calls. - Subscribers receiving MTR, diversion and/or monitoring. - Subscribers included in a group and/or a manager/secretary relation. - Appointment reminder. - Terminal locked or unlocked. - Callbacks received. - Active diversions. - Last number dialed. Data kept during permanent replacement of a terminal Replacing Reflexes terminals Irrespective of the initial and the replacement type of Reflexes terminal, the function and resource keys are not conserved. Directory numbers may be conserved, depending on the volume of the directories for the terminals concerned (for example, if a Reflexes Advanced terminal is replaced by a Reflexes Premium terminal, only the first 10 numbers are conserved). Extension units are always transferred, providing the unit concerned is supported by the replacement terminal. MOVING A TERMINAL If you move to another office, you can move your terminal from one socket to another and conserve its configuration (fully or partially). Before moving the terminal: - You must change your password, and it must differ from the default password. - It is recommended that you lock the terminal. 2/10 Réf. 3EH21017BSAA Ed. 02
113 File 15 UPGRADING YOUR SYSTEM Moving a terminal to an unused socket Unplug Plug in Movement "Terminal movement" code + Dir. P1 + password (not default password) ADDING TERMINALS When adding terminals, the limitations on the number of terminals and the possibilities provided by the system software key must be taken into account. Plug in The terminal is recognized immediately when plugged into socket. USING THE 4099 MULTI-REFLEXES HUB The Multi Reflexes 4099 allows for the connection of 3 Alcatel Reflexes terminals using just one UA link with the system; this option makes it easy to add further Reflexes terminals to the system. 2 3 UA UA/ Reflexes 1 UA/ Reflexes 1 UA/ Reflexes 1 UA/ PBX LED This option does not allow for the connection of DECT 4070 IO/EO base stations or Reflexes terminals with the V24, S0 or Z options. Ed. 02 Réf. 3EH21017BSAA 3/10
114 UPGRADING YOUR SYSTEM UA/PBX Reflexes terminal Multi-Reflexes hub Reflexes terminal 2 Interface classification - UA/PBX: SELV - UA/Reflexes 1 to 3: SELV Maximum system-terminal distances with a 4099 Multi-Reflexes Hub mm cable: 325 m mm cable: 500 m mm cable: 730 m 3-m and 10-m cables are available for connecting the terminals to the hub. ADDING / REPLACING BOARDS All replacements (CPU board, interface boards) must be performed with the system powered off. To do this: - Press the ON/OFF button: the RED LED flashes. - Wait for the LED to change to steady red (about 30 seconds): the system is powered off. PM5 allows the configuration to be saved and then restored after replacing the CPU board. 4/10 Réf. 3EH21017BSAA Ed. 02
115 File 15 UPGRADING YOUR SYSTEM ADDING A HARD DISK A hard disk is added to a CPU/CPUe or CoCPU/CoCPU@ board by means of an XMEN board. Hard disk Support XMEM board CPU board 44-point connectors connected by a flat cable A system can contain two hard disks at the most. During installation, always take anti-static precautions (wristband, heelpiece, etc.) before handling the hard disk. Electrostatic discharges can shorten the life of the disk. When going into stand-by mode, wait for red Power LED to stop flashing before you remove the module's CPU board. Extracting the disk before the switch to standby is completed can destroy part of the disk or damage its contents. Never handle the hard disk until the motor has stopped completely (about 4 seconds after the red Power LED stops flashing). Ed. 02 Réf. 3EH21017BSAA 5/10
116 UPGRADING YOUR SYSTEM ADDING AN EXTENSION MODULE One or two extension modules can be added to the basic module. PROCESSING UNIT CPU LAN AUDIO- OUT CONFIG LAN FAN POWER MODULE 1 MODULE 2 AUDIO-IN DOORPHONE MODULE CPU CPU / CPUe board STP 100-Ohm cables Category 5 (provided) Length 5m ADD-ON MODULE MAIN FAN POWER MEX MEX board (extension cabinet 1) ADD-ON MODULE MEX FAN POWER MAIN MEX board (extension cabinet 2) Fitting an extension module - The CPU slot of the extension module must be equipped with a MEX board (with an HSL1 daughter board). - Fit the CPU/CPUe board of the main module with an HSL daughter board. - Extension modules cannot contain synchronizing digital network interfaces (BRA, PRA) or Co boards. - For other boards, the same rules apply as for the basic module. 6/10 Réf. 3EH21017BSAA Ed. 02
117 File 15 UPGRADING YOUR SYSTEM MEX board ADD- ON MODULE MEX FAN PO WER MAIN RJ45 pin MAIN TX+ TX- RX+ RX- - MAIN: HSL link to the main module. Function of the LED Name Color Function POWER Two-colored Red/ - Running on mains power: green LED on steady Green - Running on battery: yellow LED on steady FAN Two-colored Red/ Green - Standby: red LED flashing - The 2 fans are operating correctly: green LED on steady - 1 or 2 fans not operating correctly: red LED on steady Adding a third module - Replace the HSL1 board of the CPU/CPUe board with an HSL2 board. - Reuse the HSL1 board, installing it on the board of the third module. In a system with two modules, the CPU/CPUe (basic module) and MEX (extension module) boards are equipped with an HSL1 board. Ed. 02 Réf. 3EH21017BSAA 7/10
118 UPGRADING YOUR SYSTEM ADDING APPLICATIONS FEATURES The table below sets out the operations that need to be performed (adding hardware, new software key required, etc.) when you want to add features such as VoIP, Internet services or CTI to a Voice installation. The VoIP and Internet features require the software applications package to be loaded, in addition to the hardware configuration changes. APPLICATIONS Hardware Software keys To order Extension to system with CPUe Extension to system with CPU VOICE FEATURES 2 system languages No special hardware requirements No key 4 system languages CPU + XMEM64 or CPUe No additional hardware XMEM64 Add2 system languages 4 pre-announcement messages No special hardware requirements No key 8 pre-announcement messages CPU + XMEM64 or CPUe No additional hardware XMEM64 No key Default "Please Wait" music:16 seconds Customized "Please Wait" music: 2 minutes NMC with 1000 metering tickets No special hardware requirements No special hardware requirements No special hardware requirements No key No key 1000 NMC tickets ARS features No special hardware requirements No key Reflexes terminal users UAI boards Add Reflexes users DECT (or Reflexes DECT) users 4070 IO/EO base stations DECT users Analog terminals users SLI boards Add analog users VOICE MAIL VMU: 2 ports - 20 minutes No special hardware requirements No key Name announcement No special hardware requirements No key Mailbox welcome messages CPU = 10 mailboxes with welcome messages or CPU + XMEM64/CPUe = 50 mailboxes with welcome messages or Hard disk = up to 200 mailboxes with welcome messages Welcome messages VMU: 4 ports - 20 minutes No special hardware requirements Add2 ports VMU: 4 ports - 80 minutes CPU + XMEM64 or CPUe No special hardware requirements XMEM64 Add2 ports + up to 80 minutes VMU: 6 ports - 80 minutes CPUe No special hardware requirements IMPOSSIBLE Add4 ports + up to 80 minutes VMU: 6 ports - 8 or 200 hours CPUe + Hard disk Hard disk IMPOSSIBLE Add4 ports + up to 8 or 200 hours VMU: 8 ports - 8 hours CPUe + Hard disk Hard disk IMPOSSIBLE Add6 ports + up to 8 hours VMU: 8 ports hours CPUe + Hard disk Hard disk IMPOSSIBLE Open all VMU features 8/10 Réf. 3EH21017BSAA Ed. 02
119 File 15 UPGRADING YOUR SYSTEM Distribution lists CPUe + Hard disk Hard disk IMPOSSIBLE Open all VMU features Recording of conversations CPUe + Hard disk Hard disk IMPOSSIBLE Open all VMU features Pre-configured Automatic Attendant & Fax/Modem Switching CPU + Hard disk No special hardware requirements XMEM64 Basic Automatic Attendant Customized Automatic Attendant & Audiotex INTERNET SERVICES CPU + XMEM64 or CPUe Hard disk Hard disk Full Automatic Attendant Internet access CPUe No additional hardware CoCPU@, XMEM64 Internet access Proxy/Cache server CoCPU@, Hard disk, SLanX4 XMEM64, CoCPU@, Hard disk, SLanX4 VPN CoCPU@, SLan X4 XMEM64, CoCPU@, SLanX4 server CoCPU@, Hard disk, SLanX4 XMEM64, CoCPU@, Hard disk, SLanX4 Full Internet service offering Full Internet service offering Full Internet service offering CTI Integrated CTI server No special hardware requirements TAPI 2.0 interface External TAPI 2.1 server No special hardware requirements TAPI 2.1 server (4 sessions, 10 monitoring) CSTA interface No special hardware requirements Client CSTA (25 sessions, 25 monitoring) PIMphony Basic No special hardware requirements PIMphony Basic PIMphony Pro No special hardware requirements PIMphony Pro PIMphony Team No special hardware requirements PIMphony Team VoIP Voice over IP network IP Telephony with Fast IP Reflexes CPU + XMEM64, CoCPU, SLanX4, VoIP daughter boards CoCPU, SLanX4 XMEM64, CoCPU, SLanX4 IP channels e-reflexes IP Telephony with e-pimphony PIMphony Pro or Team + e-pimphony Reflexes NETWORK Private access DLT2 or BRA Add B-channels ISVPN ISVPN Ed. 02 Réf. 3EH21017BSAA 9/10
120 UPGRADING YOUR SYSTEM 10/10 Réf. 3EH21017BSAA Ed. 02
121 FIRST-LEVEL MAINTENANCE FIRST-LEVEL MAINTENANCE File 16 BATTERY MAINTENANCE The batteries are replaced with the system powered off after removing the mains lead, unscrewing the back panels and undoing the battery rack. To guarantee correct balancing, replace all the batteries at the same time, using batteries of the same type, from the same supplier and the same batch. To guarantee system shutdown without data loss in the event of a mains power failure or the mains plug is unplugged at the wall socket, replace the batteries every two years. This maintenance operation is vital to guarantee sufficient power autonomy to allow the files to be saved before the system shuts down. The batteries are not charged when delivered. Saving the files in the event of a power failure cannot be guaranteed unless the batteries have been charged, which takes about 12 hours from the time when the system is powered up (CPU/CPUe switch in ON position). Battery characteristics - number: 1 (Rack 1), 2 in parallel (Rack 2) or 3 in series(rack 3) - sealed lead battery Ah / 12 V - fire resistance better than or equal to UL94-V2 - pay attention to the connection polarities Incorrect replacement of the batteries risks causing an explosion. Used batteries must be disposed of in accordance with the manufacturer's instructions. BATTERY MAINTENANCE It is recommended that the batteries of the CPU/CPUe and CoCPU/CoCPU boards are replaced by the same type of battery every 2 years. Used batteries must be disposed of in accordance with the manufacturer's instructions. MAINTENANCE OF THE VENTILATION SYSTEM Take advantage of the periodic replacement of the batteries to clean the system ventilation louvers using a brush or a cloth. Ed. 02 Réf. 3EH21017BSAA 1/4
122 FIRST-LEVEL MAINTENANCE When the system is functioning with only one fan (Rack 2 or Rack 3) or none (Rack 1) in working order, only the T0/T2 external digital accesses and the first two interfaces of the Alcatel Reflexes terminals remain operational. 2/4 Réf. 3EH21017BSAA Ed. 02
123 File 16 FIRST-LEVEL MAINTENANCE REPLACING THE CPU/CPUe BOARD The software key must be adjusted after a CPU/CPUe board has been replaced. 1. The new CPU board does not have a software key: You know the new software key corresponding to the new CPU: - start the system with the new CPU: the system works with the default settings. - load the new key via PM5or via MMC station. - execute a cold reset: the system works with the settings offered by the new key. - restore the configuration (not the old key). - If you do not know the new software key corresponding to the new CPU, use the old key while waiting to enter the new one (30 day delay). The procedure is the same as the previous one. 2. The new CPU board has a software key corresponding to the serial number: The new key offers the desired level of service: - start the system with the new CPU: the system works with the desired level of service - restore the configuration (not the old key). - The new key does not offer the desired level of service: modify the key. 3. The new CPU board has a software key that does not correspond to the serial number: you are then in situation 1, but the system starts with the level of service offered by the CPU's key with temporary validity Ed. 02 Réf. 3EH21017BSAA 3/4
124 FIRST-LEVEL MAINTENANCE MAINTENANCE OF THE HARD DISK Please follow the recommendations below: any improper treatment of the hard disk (handling, transport, storage) may result in a reduction of its service life and may also cause malfunctions of your system. Handling - Wear a device (strap, heels, etc..) to protect yourself against electrostatic discharges. - Avoid knocking the hard drive. - Do not touch the connector. - Handle the disk by holding it by the edges. Storage: - every hard disk must be stored in an anti-static bag. - Avoid all contact between hard disks. - Do not place them one on top of the other (even when packed). Transport - A hard disk cannot be transported unless packed in an electrostatic bag. - Avoid all contact between hard disks. - When transporting hard disks, use standard packaging for this purpose. 4/4 Réf. 3EH21017BSAA Ed. 02
125 GLOSSARY GLOSSARY File 17 A AFU "Auxiliary Function Unit". Daughter board of the CPU/CPUe board supporting ancillary functions such as general bell, doorphone, audio In, audio Out, etc. ARI "Access Right Identifier". System identification number (DECT function). ARS "Automatic Route Selection". A logic direction is a set of trunks used for a call with the following facilities: seeking out the optimal path for a call, using the least-cost operator or network; overflow management: enables a PBX to find a new route to make an outgoing call when there are no resources available in the initial trunk. ATA "Analog Trunk Access". Board for connecting analog network lines (switched network). B BACKGROUND MUSIC Device (e.g. radio tuner) that can broadcast music over the loudspeakers of idle terminals; broadcasting is stopped automatically if there is an incoming call to the terminal or if the user makes a call. BRA "Basic Rate Access". Board allowing for the connection of T0 digital basic accesses; each access supports a data rate of 144 kbps, structured in 2 B-channels at 64 kbps for voice and data transmission, and 1 D-channel at 16 kbps for signaling. C CPU "Central Processing Unit". Term designating the processor or microprocessor. The central processing unit executes computer program instructions. CTI "Computer-Telephone Integration". Interaction mechanism between 2 sections, namely a data processing section (computer) and a telecommunications section (PABX), independently of the physical layout of the 2 sections. D DASS2 "Digital Access Signaling Specification number 2" Ed. 02 Réf. 3EH21017BSAA 1/7
126 GLOSSARY DDI "Direct Dialing In". Direct external call number for the system terminals (depending on the configuration with the public network operator). DECT "Digital Enhanced Cordless Telecommunication". European cordless telephony standard. DECT terminal: cordless terminal that complies with this standard. DHCP "Dynamic Host Configuration Protocol". Protocol that manages IP address allocation dynamically so that addresses can be reassigned when no longer being used by LAN hosts. DISA "Direct Inward Station Access". Services (analog DISA and Transit DISA) enabling outside callers to dial a specific number giving direct access to the system. DNS "Domain Name Server". System used on the Internet for converting domain names or machine names into IP addresses. A domain name, unlike an IP address, is an easily memorized Internet address. E ETHERNET Local network (LAN) operating at 10 or 100 Mbps (10 base T or 100 base T) over a coaxial cable. Ethernet is similar to the IEEE series standards. F FTP/STP/UTP "Foiled Twisted Pairs/Shielded Twisted Pairs/Unshielded Twisted Pairs". Types of connection cables to be used between Alcatel OmniPCX Office and an external distribution panel. G GENERAL BELL If the operator is absent, internal and external calls to the operator are directed to an external signaling device that lets any authorized terminal take these calls. H HSL "High Speed links". Link between the basic module and the extension module; requires the CPU and MEX boards to be equipped with an HSL daughter board. I IPSec "Internet Protocol Security". Standard taking network security into account. Protocol used in the implementation of VPNs, and for remote access by connection to a VPN. 2/7 Réf. 3EH21017BSAA Ed. 02
127 File 17 GLOSSARY ISDN "Integrated Services Digital Network". Standard for the transmission of digital data over telephone cables or other communication vectors. ISP "Internet Service Provider". A company that provides Internet access for individuals and enterprises, along with other services, such as web site construction and hosting. ISVPN "Integrated Services Virtual Private Network". Protocol used in a private virtual digital network; it offers functions such as transfer optimization and the transmission of information such as the name, busy status or diversions. K KEY SYSTEM (mode) Reflexes terminal operating mode in which the terminal features as many resource keys (RSP: Physical resource) as there are network lines in the system. L LAN "Local Area Network". Network of interconnected machines that share the resources of a processor or server in a relatively restricted geographical area, usually the premises of a company. LOUDSPEAKER External loudspeaker used for the broadcasting messages. M MANAGER/SECRETARY Set of specific services (profile, filtering, diversion) between a manager terminal and a secretary terminal. MEX Add-on module. Controller board for extension module. MIX Mixed equipment board: T0 access, analog and reflexes terminal connection interfaces. MULTILINE TERMINAL Terminal that has several lines for managing several calls at the same time. Ed. 02 Réf. 3EH21017BSAA 3/7
128 GLOSSARY N NMC "Network Management Center". Workstation allowing a telephone system administrator to remotely manage, administer (storage of call metering tickets for example) and optimize one or more Alcatel OmniPCX Office systems. O OS "Operator Station". Dedicated Reflexes terminal for answering incoming calls from the public network. P PASSWORD Code acting as a password controlling access to voice mail and locking of terminals. PBX (mode) Mode of operation of Reflexes terminals; in this mode, all the network lines are materialized by general-purpose resource keys (RSB). PLEASE WAIT MESSAGE An audio component of the system (or an external device, such as a cassette player) which plays a message or piece of music while keeping an external correspondent on hold. POP3 "Post Office Protocol". Standard Internet protocol for receiving electronic messages. POP3 is a client/server protocol in which the messages are received and hosted by the ISP. When a message is read, it is transferred to the client terminal and is no longer hosted by the ISP. PPP "Point to Point Protocol". Protocol used in communication between two computers using a serial interface (typically between a PC connected to a server via a telephone line). PRA "Primary Rate Access". Board allowing for the connection of a T2 digital primary access; the access supports 48 kbps structured in 30 B-channels at 64 kbps for voice and data transmission, and 1 D- channel at 64 kbps for signaling. PROXY A proxy server is used as an interface between a user and the external Internet network. Q QSIG "Q Signaling Protocol". Set of standard signaling protocols between the private PBXs of a telephone network (Q reference point) interconnected by digital ATLs. 4/7 Réf. 3EH21017BSAA Ed. 02
129 File 17 GLOSSARY S S0 BUSES Types of connection for S0 digital terminals (passive short bus, long bus/short point-to-point bus, extended bus); the connection between the S0 buses and terminals is made via an optional S0 embedded in an Alcatel Reflexes terminal. SELV "Safety Extra Low Voltage". Classification of interfaces in accordance with standards EN60950 and IEC 950. SLAN "LAN switch". Daughter board for mounting on a CoCPU/CoCPU@ board to enable it to communicate with the CPU/CPUe. SLI "Single Line Interface". Board allowing the connection of analog terminals (still called Z terminals). T TCP/IP "Transmission Control Protocol/Internet Protocol". Standard protocol used on the Internet. TERMINAL GROUPS Series of terminals grouped under the same directory number. A call to the number is routed to one of the free terminal lines. TFTP "Trivial File Transfer Protocol". The simplest network application allowing file transfer. TL "Analog trunk line" connecting the system to the public switched network. U UAI "Universal Alcatel Interface". Board used for the connection of Alcatel Reflexes terminals or DECT 4070 IO/EO base stations. V VMU Voice Mail Unit. The integrated voice server provides a voice mailbox for each user as well as a general voice mailbox and features such as Personal Assistant, Automatic Attendant and Audiotex. VoIP "Voice over IP". Term designating voice transmission over a data network using the Internet protocol. VPN "Virtual Private Network". Private data network that uses the public telecommunications infrastructure (e.g. the Internet) while maintaining confidentiality by means of tunneling protocols and security procedures. Ed. 02 Réf. 3EH21017BSAA 5/7
130 GLOSSARY W WAN "Wide Area Network". A geographically dispersed telecommunications network. The term WAN is used in contrast to LAN. 6/7 Réf. 3EH21017BSAA Ed. 02
131 File 17 GLOSSARY X XMEM "EXpansion Memory". Daughter board of the CPU board that extends the memory capacity and allows a hard disk to be connected. Ed. 02 Réf. 3EH21017BSAA 7/7
SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3
SIP Proxy Server Administrator Installation and Configuration Guide V2.31b 09SIPXM.SY2.31b.EN3 DSG, DSG logo, InterPBX, InterServer, Blaze Series, VG5000, VG7000, IP590, IP580, IP500, IP510, InterConsole,
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
Quick Start Guide. Cisco SPA232D Mobility Enhanced ATA
Quick Start Guide Cisco SPA232D Mobility Enhanced ATA Package Contents Analog Telephone Adapter Ethernet Cable Phone Cable Power Adapter Quick Start Guide Product CD-ROM Welcome Thank you for choosing
PCS300 Universal IP Reporting Module V1.0
PCS300 Universal IP Reporting Module V1.0 Reference and Installation Manual Patents: One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111,
IP DSLAM IDL-2402. Quick Installation Guide
IP DSLAM IDL-2402 Quick Installation Guide Table of Contents Package Contents... 3 Overview... 4 Setup the IDL series IP DSLAM... 5 Safety Instruction... 5 Hardware Installation... 6 WEB Configuration...
P-2024. Quick Start Guide. VoIP Analog Telephone Adaptor DEFAULT LOGIN. IP Address http://192.168.5.1 Password 1234. Version 3.60 7/2007 Edition 1
P-2024 VoIP Analog Telephone Adaptor Quick Start Guide Version 3.60 7/2007 Edition 1 DEFAULT LOGIN IP Address http://192.168.5.1 Password 1234 Copyright 2007. All rights reserved. Overview Use your P-2024
MyPBX U510 Installation Guide
MyPBX U510 Installation Guide Version 1.1 Date: 9th, Aug, 2013 Yeastar Information Technology Co. Ltd Contents 1. PREPARATION BEFORE INSTALLATION... 4 2. HARDWARE SPECIFICATIONS... 5 2.1 Overview... 5
Setting Up the Cisco Unified IP Phone
CHAPTER 3 This chapter includes the following topics, which help you install the Cisco Unified IP Phone on an IP telephony network: Before You Begin, page 3-1 Understanding the Cisco Unified IP Phone 7962G
Setting Up the Cisco Unified IP Phones
CHAPTER 3 This chapter includes the following topics, which help you install the Cisco Unified IP Phones on an IP telephony network: Before You Begin, page 3-1 Understanding the Cisco Unified IP Phone
DECT Gigaset N510 IP PRO
DECT Gigaset N510 IP PRO SUMMARY Summary... 1 1. System Features of the DECT Gigaset N510 IP Pro... 2 Base Station Gigaset N510 IP Pro... 2 Environmental Requirements... 3 The base should be placed in
NeoGate TA Series Quick Installation Guide
NeoGate TA Series Quick Installation Guide Version: V1.1 Yeastar Technology Co., Ltd. Date: November 18, 2014 http://www.yeastar.com 1/15 Contents NeoGate TA Series Quick Installation Guide 1. Preparation
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
MyPBX U100 & U200 Installation Guide
MyPBX U100 & U200 Installation Guide Version: V1.0 Yeastar Technology Co., Ltd Date: 25 th February, 2013 http://www.yeastar.com 1/14 Contents MyPBX U100 & U200 Installation Guide 1. PREPARATION BEFORE
ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
Phone Adapter. with 2 Ports for Voice-over-IP. Installation and Troubleshooting Guide. Model No. PAP2 Ver. 2. Voice
Phone Adapter with 2 Ports for Voice-over-IP Voice Installation and Troubleshooting Guide Model No. PAP2 Ver. 2 Copyright and Trademarks Specifications are subject to change without notice. Linksys is
SL1100 Installation Instructions. This Installation Packet is Organized into Five Chapters:
Thank you for choosing NEC SL1100 Distributors! This Installation Packet is Organized into Five Chapters: BLUE: Hardware Installation Overview (Block Wiring, Music On-Hold, Paging, Door Box & Relays) GREEN:
Wireless Router Setup Manual
Wireless Router Setup Manual NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10082-02 2006-04 2006 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear,
Setting Up and Testing the MAX Hardware
Page 1 of 12 Setting Up and Testing the MAX Hardware This chapter covers these topics: Planning the hardware installation Inserting an expansion card Setting up the hardware Connecting to input power Connecting
Broadband Router ESG-103. User s Guide
Broadband Router ESG-103 User s Guide FCC Warning This equipment has been tested and found to comply with the limits for Class A & Class B digital device, pursuant to Part 15 of the FCC rules. These limits
Connecting the DG-102S VoIP Gateway to your network
Contents of Package: DG-102S VoIP Station Gateway Power adapter CD-ROM, including User s Manual Quick Install Guide Requirements: RS-232 Console Cable Two RJ-45 CAT-5 Straight-Through Cables For more information
Quick Start Guide. Cisco SPA100 Series Analog Telephone Adapters. SPA112 Two Port Phone Adapter SPA122 ATA with Router
Quick Start Guide Cisco SPA100 Series Analog Telephone Adapters SPA112 Two Port Phone Adapter SPA122 ATA with Router Package Contents Analog Telephone Adapter Ethernet Cable Power Adapter Quick Start Guide
Setting Up the Cisco IP Phone
CHAPTER 3 This chapter includes this following topics, which help you install the Cisco IP Phone on an IP telephony network: Before You Begin, page 3-1 Installing the Cisco IP Phone, page 3-6 Adjusting
VOICE RECORDING SYSTEM ISDN PRI / BRI
Sense Box VOICE RECORDING SYSTEM ISDN PRI / BRI / Analog SUB-SYSTEM ISDN2, ISDN30 Sense Box USER MANUAL TABLE OF CONTENTS 1. STATUTORY INFORMATION... 3 1.1 SAFETY WARNING... 3 1.2 SAFETY EXTRA LOW VOLTAGE
Frontier DSL SelfConnect Guide
Frontier DSL SelfConnect Guide Frontier DSL Self-Installation Guide Table of Contents Getting Started...2 Customer and Computer Requirements...2...3 STEP 1: Install Microfilters...3 STEP 2: Install Your
Quick Start Guide. RV0xx Series Routers
Quick Start Guide RV0xx Series Routers RV042 Dual WAN VPN Router RV042G Gigabit Dual WAN VPN Router RV082 Dual WAN VPN Router RV016 Multi-WAN VPN Router Package Contents VPN Router Power Adapter (Cisco
ADSL Modem Installation Guide. Model # 36R515 Part # 030-300108 Rev. D Revision Date 12/2000. ADSL Modem Installation Guide
ADSL Modem Installation Guide Model # 36R515 Part # 030-300108 Rev. D Revision Date 12/2000 ADSL Modem Installation Guide Installation Instructions Westell ADSL Modem 1. Package Inspection and Contents...2
Alcatel Easy Reflexes. Alcatel OmniPCX Enterprise
Alcatel Easy Reflexes Alcatel OmniPCX Enterprise How to use this guide You have an Alcatel Easy REFLEXES digital telephone. Actions Off-hook Display Hang up Description of an action or context Partial
Ultra Thin Client TC-401 TC-402. Users s Guide
Ultra Thin Client TC-401 TC-402 Users s Guide CONTENT 1. OVERVIEW... 3 1.1 HARDWARE SPECIFICATION... 3 1.2 SOFTWARE OVERVIEW... 4 1.3 HARDWARE OVERVIEW...5 1.4 NETWORK CONNECTION... 7 2. INSTALLING THE
Alcatel-Lucent OmniPCX Enterprise Communication Server TA-MMK (MMK V2)
Alcatel-Lucent OmniPCX Enterprise Communication Server TA-MMK (MMK V2) Legal notice: Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are
Quick Start Guide. RV 120W Wireless-N VPN Firewall. Cisco Small Business
Quick Start Guide Cisco Small Business RV 120W Wireless-N VPN Firewall Package Contents Wireless-N VPN Firewall Ethernet Cable Power Adapter Quick Start Guide Documentation and Software on CD-ROM Welcome
CPEi 800/825 Series. User Manual. * Please see the Introduction Section
CPEi 800/825 Series User Manual * Please see the Introduction Section Contents Introduction...iii Chapter 1: CPEi 800/825 User Guide Overview... 1-1 Powerful Features in a Single Unit... 1-2 Front of the
3.5 EXTERNAL NETWORK HDD. User s Manual
3.5 EXTERNAL NETWORK HDD User s Manual Table of Content Before You Use Key Features H/W Installation Illustration of Product LED Definition NETWORK HDD Assembly Setup the Network HDD Home Disk Utility
Alcatel Premium Reflexes Alcatel Easy Reflexes. Alcatel OmniPCX Office ARCHITECTS OF AN INTERNET WORLD
Alcatel Premium Reflexes Alcatel Easy Reflexes Alcatel OmniPCX Office ARCHITECTS OF AN INTERNET WLD User guide how Thank you for choosing one of our Reflexes, range of telephones, and for your confidence
PRImaGate Switch RACK 3U
From 8 to 32 channels Integrated LCR / Router Voice Call Back SMS Server VOIP RACK 3U SMS PRESENTATION Specially designed for big companies, call-centres and companies whom GSM traffic is high, PRImaGate
LifeSize Networker Installation Guide
LifeSize Networker Installation Guide November 2008 Copyright Notice 2006-2008 LifeSize Communications Inc, and its licensors. All rights reserved. LifeSize Communications has made every effort to ensure
Model PBX 308 Plus System Administration Guide
Model PBX 308 Plus System Administration Guide Introduction 4 Installation Hints 4 System Programming 5 - System Password 5 - Changing Password 5 Exchange Line Set up 6 - Caller Display 6 - Setting Date
PBX System. Installation Manual AS 200 IT
PBX System Installation Manual AS 200 IT Safety Notes - Installation and Maintenance of the System only by trained personnel. - Important! To prevent personal injury and damage to equipment please ensure
Linksys Gateway SPA2100-SU Manual
Linksys Gateway SPA2100-SU Manual Manuel de l'utilisateur Table of Contents Looking for Basic Setup Instructions?... 3 Most Recent Version of this Manual... 3 Advanced Setup Instructions... 4 Wiring Your
System Administration Guide. Model KS 832. Expandable up to 1664
System Administration Guide Model KS 832 Expandable up to 1664 Introduction 4 Installation Hints 4 System Programming 5 - System Password 5 - Changing Password 5 Exchange Line Set up 6 - Caller Display
Contents. Section A Networking Basics... 1. 1 Learning the Basics... 3. Section B Wired Ethernet Networking... 17
Contents Section A Networking Basics...................................... 1 1 Learning the Basics............................................. 3 Selecting a network connection........................................
2 Setting Up the Hardware for a Wired Ethernet Network... 13. 3 Setting Up the Software for an Ethernet Network... 21
Contents 1 Networking Basics............................................... 1 Selecting a network connection........................................ 2 Wired Ethernet network...........................................
Ethernet Radio Configuration Guide
Ethernet Radio Configuration Guide for Gateway, Endpoint, and Repeater Radio Units April 20, 2015 Customer Service 1-866-294-5847 Baseline Inc. www.baselinesystems.com Phone 208-323-1634 FAX 208-323-1834
Users manual. TCW181B-CM_R1 Page 1
Ethernet controller TCW181B-CM Users manual 1. Short description TCW181B-CM is 8-channel Ethernet relay board, which is designed to work in IP-based networks and managed by WEB interface or SNMP programs.
IPG/7700 Hardware Manual SYSTECH. Document number 80-001099-7 Revision A
IPG/7700 Hardware Manual SYSTECH C O R P O R A T I O N Document number 80-001099-7 Revision A Created 2010, and Protected Under the U.S. Copyright Act of 1976. Copyright 2010, SYSTECH Corporation All Rights
OmniAccess 5320 BG. Business Gateway. User s Guide
OmniAccess 5320 BG Business Gateway User s Guide Important Information Loss of Power/DSL Service Safety Disposal Alternative arrangements should be made to enable you to contact the emergency services
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
How To Use An Ip Phone With A Sim Sim Sims 2 (Iphone) Or Ip Phone (Ip Phone) With A Microsoft Ip Phone 2 (Ipphone) With An Ipro (Ipro) Or Sims 1 (Ip
Thomson Telecom S.A.S with a capital of 130 037 460 RCS 390 546 059 Copyright THOMSON 2005 All rights reserved 09/2005-1 www.speedtouchpartner.com ST2030 TM SIP European Community Declaration of Conformity
Clino Call DECTplus. Wireless communication
Clino Call DECTplus Wireless communication System overview Clino Call DECTplus is a cordless communication solution that can be extended significantly both with respect to its expansion options as well
NeoGate TA Series Installation Guide
NeoGate TA Series Installation Guide Version 1.2 Date: April 1, 2015 Yeastar Information Technology Co. Ltd Contents 1. Preparation before Installation... 3 2. Hardware Specifications... 5 2.1 Overview...
OM2260VW2 USER MANUAL VERIZON WIRELESS HOME PHONE CONNECT
OM2260VW2 USER MANUAL VERIZON WIRELESS HOME PHONE CONNECT Welcome to Verizon Wireless Thank you for choosing Verizon Wireless Home Phone Connect. You re now connected to the power of America s most reliable
TIME BOX BIOMETRIC TECHNICAL INSTRUCTIONS AND QUICK START GUIDE IT IS RECOMMENDED TO READ THIS MANUAL BEFORE OPERATING THE SYSTEM
TIME BOX BIOMETRIC TECHNICAL INSTRUCTIONS AND QUICK START GUIDE IT IS RECOMMENDED TO READ THIS MANUAL BEFORE OPERATING THE SYSTEM BODET Software B.P. 402 Boulevard du Cormier F-49302 CHOLET Cedex www.bodet.com
MAX T1/E1. Quick Start Guide. VoIP Gateway. Version 1.0
MAX T1/E1 TM VoIP Gateway Quick Start Guide Version 1.0 Contents INTRODUCTION 1 Hardware Needed Software Needed 1 1 NET2PHONE MAX SET UP Hardware Set Up Software Set Up Set Up Internet Protocol (IP) Address
Rousseau 10. User Guide
Rousseau 10 User Guide Base station overview ➀ LED signals White, permanent light: - Base station ready, you can register a handset Slow flashing white light: - Paging call in progress - Active call (you
TrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
Wireless VoIP Phone User s Manual
Wireless VoIP Phone User s Manual Table of Contents Chapter 1 Overview of the WiFi phone... 5 1.1 Front Panel and Keypad...5 1.2 Removing and Installing the Battery...7 1.3 Charging the WIFI PHONE...8
Getting Started KX-TDA5480
4-Channel VoIP Gateway Card Getting Started KX-TDA5480 Model KX-TDA0484 Thank you for purchasing the Panasonic 4-Channel VoIP Gateway Card, KX-TDA5480/KX-TDA0484. Please read this manual carefully before
Cisco Unified IP Conference Phone 8831 Installation
Cisco Unified IP Conference Phone 8831 Installation Cisco Unified IP Conference Phone 8831 Installation Overview, page 1 Before You Begin, page 1 Cisco Unified IP Conference Phone 8831 Components, page
Getting Started. Table of Contents. Hybrid IP-PBX
Hybrid IP-PBX Getting Started Model no. KX-TDA30 Table of Contents 1 Before Installation... 2 2 Installation... 4 3 Starting the Hybrid IP-PBX... 11 4 Customising the Hybrid IP-PBX... 14 5 Confirming the
Model PBX 308 Plus System Administration Guide
Model PBX 308 Plus System Administration Guide Introduction 3 Installation Hints 4 System Programming 5 IMPORTANT Exchange Lines 6 Assign Incoming calls to ring Nominated Extensions 7 Cascade Ringing Of
PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.
Trademarks Copyright PLANET Technology Corp. 2004 Contents subject to revise without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective
How To Set Up A Gxp280 Ip Phone On A Cell Phone On Your Computer Or Ip Phone (Siphone) On A Sim Sim Sim Or Ipro (Cell Phone) On Your Ipro Or Ipo (Cellphone) On
GXP280 Small Business IP Phone Quick Installation Guide Part Number: 9620001302A Document Version Number: 1.0 1 GXP280 IP Phone Quick Installation Guide WARNING: Please DO NOT power cycle the GXP280 when
PRO 5000 CPE 1D Quick Installation Guide
PRO 5000 CPE 1D Quick Installation Guide Introduction This Quick Installation Guide covers the basic installation of the PRO 5000 CPE. For more information, refer to the relevant sections in the Product
Chapter 15: Advanced Networks
Chapter 15: Advanced Networks IT Essentials: PC Hardware and Software v4.0 1 Determine a Network Topology A site survey is a physical inspection of the building that will help determine a basic logical
Pancode VoIP/Pantel VoIP Access Control Door Phones. Installation and Programming Manual Release 1.0 June 2006
Pancode VoIP/Pantel VoIP Access Control Door Phones Installation and Programming Manual Release 1.0 June 2006 Table of Contents 1 Introduction... 2 1.1 Pancode VoIP/Pantel VoIP Kit Contents... 3 2 Physical
Ericsson W25. Mobile Networks. Quick Installation Guide
Ericsson W25 Fixed Wireless Terminal for WCDMA/HSDPA Mobile Networks Quick Installation Guide Table of Contents INTRODUCTION... 3 Package Contents... 3 Requirements... 3 INSTALLATION... 4 Unit Preparation...
Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.
TA Instruments TRIOS Software Installation Instructions Installation Requirements Your TRIOS Instrument Control software includes all the components necessary to install or update the TRIOS software, as
User Manual. PePWave Surf / Surf AP Indoor Series: Surf 200, E200, AP 200, AP 400. PePWave Mesh Connector Indoor Series: MC 200, E200, 400
User Manual PePWave Surf / Surf AP Indoor Series: Surf 200, E200, AP 200, AP 400 PePWave Mesh Connector Indoor Series: MC 200, E200, 400 PePWave Surf AP Series: Surf AP 200-X, E200-X, 400-X PePWave Surf
Ethernet Adapter Owner's Manual
Corinex Intelligent PowerNet Corinex Intelligent PowerNet Ethernet Adapter Owner's Manual This Owner s Manual, as well as the software described in it, is furnished under license and may be used or copied
GXP-2020 6-line SIP Enterprise Phone Quick Installation Guide
1 GXP-2020 6-line SIP Enterprise Phone Quick Installation Guide WARNING: Please DO NOT power cycle the GXP-2020 when LED lights are flashing during system boot up or firmware upgrade. You may corrupt firmware
GEU-0822 8-Port Gigabit Switch
GEU-0822 8-Port Gigabit Switch 1 V1. 1_20150622 1. INTRODUCTION... 3 1.1 Product Briefs... 3 1.2 Product Features... 3 1.3 Hardware Introduction... 4 2. CONNECTING THE SWITCH... 5 2.1 Package Contents...
InnoMedia ESBC 9580-4B. Quick Install Guide. www.innomedia.com 1
InnoMedia ESBC 9580-4B Quick Install Guide www.innomedia.com 1 Table of Contents Introduction 2 Package Contents 2 CAUTION 2 Installation 3 Wall-Mounting Instructions 5 Troubleshooting 6 Appendix A. LED
USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog
USER MANUAL PingBrother EPIW104 managed passive poe switch & IP watchdog CONTENT Content... 2 Chapter 1... 3 1.1 Preface... 3 1.2 CE mark warning... 3 1.3 FCC warning... 4 Chapter 2... 5 2.1 Physical description...
P-2302HWUDL-P1. Quick Start Guide. 802.11g Wireless VoIP Station Gateway. with Built-in DECT Base Station
P-2302HWUDL-P1 802.11g Wireless VoIP Station Gateway with Built-in DECT Base Station Quick Start Guide Version 3.60 Edition 1 3/2007 Overview The P-2302HWUDL-P1 model is a router with IEEE 802.11g wireless
AXIS 291 1U Video Server Rack Installation Guide
AXIS 291 1U Video Server Rack Installation Guide About This Document This document describes how to install Axis blade video servers in the AXIS 291 1U Video Server Rack. Updated versions of this document
10/2011 - English Edition 1. Quick Start Guide. NWA1100N-CE CloudEnabled Business N Wireless Access Point
10/2011 - English Edition 1 Quick Start Guide NWA1100N-CE CloudEnabled Business N Wireless Access Point Package Contents - 1 x ZyXEL NWA1100N-CE Access Point - 2 x Detachable Antennas - 1 x Power Adapter
Link Link sys E3000 sys RE1000
User Guide High Performance Extender Wireless-N Router Linksys Linksys RE1000 E3000Wireless-N Table of Contents Contents Chapter 1: Product Overview 1 Front 1 Top 1 Bottom 1 Back 2 Chapter 2: Advanced
User Manual 821121-ATA-PAK
User Manual 821121-ATA-PAK IMPORTANT SAFETY INSTRUCTIONS When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to
How To Use A Modem On A Pc Or Mac Or Ipad (For A Laptop)
CLEAR MODEM with Wi-Fi USER GUIDE GET TO KNOW YOUR CLEAR MODEM WITH WI-FI 3 WHAT S IN THE BOX? 3 INFORMATIVE LED INDICATORS 3 USE WITH CARE 3 SET UP THE MODEM 4 PLACE THE MODEM ON A FLAT, STABLE SURFACE
User Guide. Guide d utilisation Guida dell'utente Benutzerhandbuch Guía del usuario Guia do Usuário WNA-100. Wireless Network Adapter
WNA-100 Wireless Network Adapter User Guide Guide d utilisation Guida dell'utente Benutzerhandbuch Guía del usuario Guia do Usuário www.xerox.com/office/wna Copyright 2007 Xerox Corporation. All Rights
Table of Contents. Chapter1. Introduction...1. 1.1 Before Installation... 1 1.2 System Requirements... 1
Table of Contents Chapter1. Introduction...1 1.1 Before Installation... 1 1.2 System Requirements... 1 Chapter2. IVS-110 1-Channel Internet Video Server...2 2.1 Package Content... 2 2.2 Physical Installation...
SAGEM F@st TM 1201/1241 V2
SAGEM F@st TM 1201/1241 V2 Quick Installation Guide 253156400-A_GIR 1201 V2 STD-gb.i1 1 14/10/2008 16:59:35 Contents 1 contents of the pack...2 2 connecting YOUR MODEM...3 2.1 Connecting your router...3
User manual Rev 1.3 Contents
User manual Rev 1.3 Contents 1. Introduction...4 2. System specifications...5 2.1.. General overview...5 2.2. Maximum capacity...6 2.3. Electrical specifications...6 2.4. Mechanical specifications...6
Model PBX 416 Plus System Administration Guide
Model PBX 416 Plus System Administration Guide Introduction 4 Installation Hints 4 System Programming 5 - System Password 5 - Changing Password 5 - Entering password in Direct 5 Dial Mode Exchange Line
N300 WiFi Range Extender
Model EX2700 User Manual July 2014 202-11395-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on
TD-8610/TD-8610B External ADSL2+ MODEM
TD-8610/TD-8610B External ADSL2+ MODEM Rev: 1.0.2 1910010011 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other
IEEE 802.11b WLAN PC Card
IEEE 802.11b WLAN PC Card User s Guide Version: 1.3 August 2001 Please install the Utility/Driver first before inserting the PCMCIA Card. FCC Class B Radio Frequency Interference Statement The manufacturer
Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220
Installation Guide Wireless N Access Point EAP110/EAP120/EAP220 CONTENTS Network Topology 01 Hardware Overview 02 Hardware Installation 05 1. Installation Requirements... 05 2. Mounting Bracket... 05
Quick Start Guide. Cisco Small Business. 300 Series Managed Switches
Quick Start Guide Cisco Small Business 300 Series Managed Switches Welcome Thank you for choosing the Cisco 300 Series Managed Switch, a Cisco Small Business network communications device. This device
Link Gate SIP. (Firmware version 1.20)
Link Gate SIP (Firmware version 1.20) User guide v1.0 1 Content 2 1. Technical parameters - Dimensions 133 x 233 x 60 mm - Weight 850 g - Operating position various - Operating condition temperature: +5
Actiontec GT784WN Router
Table of Contents General Information...1 Verify Computer Settings...1 Router Installation...3 Configuring Your Router...3 Configuring Your Computer...7 Configuring Your Email...9 General Information Router
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273
Prestige 202H Plus. Quick Start Guide. ISDN Internet Access Router. Version 3.40 12/2004
Prestige 202H Plus ISDN Internet Access Router Quick Start Guide Version 3.40 12/2004 Table of Contents 1 Introducing the Prestige...3 2 Hardware Installation...4 2.1 Rear Panel...4 2.2 The Front Panel
SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems
SNMP Web card User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Overlook... 3 1.4 Installation and
Model PBX 416+ Programming & User Guide
Model PBX 416+ Programming & User Guide 1 Introduction... 5 Installation hints... 5 Wall mounting... 5 System programming... 6 System password... 6 Changing the password... 6 Exchange line set up... 6
16-Port and 24-Port 10/100 Switches
16-Port and 24-Port 10/100 Switches Use this guide to install the following products: SR216 SR224 16-Port 10/100 Switch 24-Port 10/100 Switch User Guide COPYRIGHT & TRADEMARKS Specifications are subject
WLAN600 Wireless IP Phone Administrator s Guide
WLAN600 Wireless IP Phone Administrator s Guide Trademark Acknowledgement All brand names are trademarks or registered trademarks of their respective companies. Disclaimer This document is supplied by
PU-USBX. USB over Ethernet Extender OPERATION MANUAL
PU-USBX USB over Ethernet Extender OPERATION MANUAL Safety Precautions Please read all instructions before attempting to unpack or install or operate this equipment, and before connecting the power supply.
HG659 Home Gateway. User Guide HUAWEI TECHNOLOGIES CO., LTD.
HG659 Home Gateway User Guide HUAWEI TECHNOLOGIES CO., LTD. Product Overview...................................... 1 Ports and Buttons.................................................. Indicators.........................................................
T3 Mux M13 Multiplexer
T3 Mux M13 Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The abstract
