Designer Quality Control Plan Guidelines
|
|
|
- Kelley Todd
- 10 years ago
- Views:
Transcription
1 Designer Quality Control Plan Guidelines Guidelines, as defined for this manual, are detailed minimum requirement to implement a Designer Quality Control Plan 7/9/2014
2 Quality Control Plan Acknowledgement Form Project Name: Design Status: Project Number: The undersigned have read and concur with this Quality Control Plan: Date Date Date Date Date Date MSDGC Designer Quality Control Plan Guidelines Page 2 of 14 7/09/2014
3 Table of Contents Cover 1 Quality Control Plan Acknowledgement Form 2 Table of Contents 3 Section 1 Introduction 1.1 Purpose Roles and Responsibilities 4 Section 2 Minimum Requirements (Consultant QC Plan must have these EXACT headings in the order shown) 2.01 Project Description Lead Consultant s Quality Control Organization Project Team List of Deliverables, Responsible Persons, Completion Dates Design Review Process Document Control Sub Consultant Quality Control Computer Aided Design (CAD) Management Schedule Management Field Survey Quality Control Quality Control Check Process 7 Checklists/Forms Design Quality Control Checklist 8 MSDGC Easement Checklist 11 Quality Control Sign Offs Form for Design Submittals 13 QC Verification Letter Example 14 MSDGC Designer Quality Control Plan Guidelines Page 3 of 14 7/09/2014
4 Section 1 Introduction 1.1 Purpose The purpose of these guidelines is to assist the consultant led project team in creating a project specific Designer Quality Control Plan for preconstruction activities. These guidelines represent minimum requirements for plan implementation. The Design Consultant s corporate officer responsible for quality merges these guidelines with corporate Quality Assurance/Quality Control requirements. The Design Consultant is responsible for the overall quality of the final design product and is required to incorporate the review of all sub consultant s work into the project specific Designer Quality Control plan. A well structured Designer Quality Control Plan helps to ensure that designs are economical, constructible, maintainable and appropriate for their locations and surroundings. The project team is required to submit the project specific Designer Quality Control Plan to MSDGC Document Control. MSDGC s Quality Assurance Engineer approves the project specific Designer Quality Control Plan prior to the Consultant starting any design work. Adherence to the project specific Designer Quality Control Plan is required regardless of schedule or deadlines. The project specific Designer Quality Control Plan assists with the verification that the design and project documents are produced with due diligence using acceptable industry standards, appropriate techniques, available resources and reasonable decisions by competent professionals. The project specific Designer Quality Control Plan is a process tool and does not replace the sound judgment and experience of competent professionals. It is the project design team s responsibility to ensure the quality of project documents before they are submitted to MSDGC. MSDGC reserves the right to audit the Design Consultant for compliance with Quality Assurance/Quality Control procedures as provided in the Master/Professional Services Agreement. No additional compensation is provided to the Design Consultant for time or materials associated with the audit. 1.2 Roles and Responsibilities Designer s Corporate Officer Responsible for Quality: o Prepares and administers corporate quality standards. o Reviews project specific Designer Quality Control Plans for compliance with corporate policies/standards Quality Assurance Manager: o Verifies that all project documents were checked in accordance with the Quality Assurance/Quality Control procedures. o Cannot perform ANY of the Quality Control Procedures. MSDGC Designer Quality Control Plan Guidelines Page 4 of 14 7/09/2014
5 1.2.3 Engineer of Record: o Responsible for the design. o Stamps the final plans and calculations. o Licensed in the State of Ohio CAD Manager: o Verifies that all project drawings follow MSDGC s CAD Standards (conveyance projects) or National CAD Standards (treatment projects) and the project Specific CAD Management Plan. o Develops a CAD management strategy to unify the project teams CAD work (including sub consultants) Project Team Design Leader: o Typically is the Project Manager for the Design Consultant. o Implements the Quality Assurance/Quality Control Procedures Discipline Design Lead: o Ensures Quality Assurance/Quality Control procedure compliance within their specialized discipline (including sub consultants). o Monitors design activities for compliance with criteria and standards. o Verifies that assigned personnel are capable of performing the required analysis or calculations. o Releases the completed contract documents for their specialized discipline (Do not release any contract documents until the Quality Assurance/Quality Control process is complete) Originator (Designer): o Responsible for design completeness, accuracy, adequacy and inter disciplinary coordination. o Responsible to ensure quality control is performed and documented. o Cannot rely upon the Quality Assurance/Quality Control procedure to correct design or calculation deficiencies. o Presents all calculations in a neat and logical manner to facilitate checking. o Reviews the completed plan set to ensure that it satisfies the design intent. o Cannot function as the Checker or Quality Assurance Manager Checker: o Checks work product independently of the Originator. o Can only check work that he/she did not originate. o Must be competent and experienced in the type of element being checked. o Cannot function as the Originator, Back Checker or Quality Assurance Manager Back Checker: o Reviews corrections asserted by the Checker. o In most cases, the Back Checker is the Originator. o Cannot function as the Verifier or Quality Assurance Manager. MSDGC Designer Quality Control Plan Guidelines Page 5 of 14 7/09/2014
6 Corrector: o Incorporates all corrections. o In most cases, the Corrector is the Originator. o Cannot function as the Verifier or Quality Assurance Manager Verifier: o Verifies back checked corrections were accurately made. o Confirms all information is highlighted to verify that all information was checked. o In most cases, the Verifier is the Checker. o Cannot function as the Corrector or Quality Assurance Manager. Section 2 Minimum Requirements 2.01 Project Description Provide a general overview of the project and the various disciplines involved in the design. State what development phase the project specific Designer Quality Control Plan is for (Planning, Design or both) Lead Consultant s Quality Control Organization Provide identification, responsibility and authority of Design Consultant s corporate Quality Control officer/manager and an organizational chart describing the Consultant s quality assurance team/manager s interface with the project team Project Team Provide a list of the key personnel on the project for the prime and sub consultants. The list will include Originator (Designer), Checker, Back Checker, Corrector, Verifier, Cad Manager, Quality Assurance Manager and Engineer of Record. A brief resume shall be provided for personnel listed. It is important to note that if a personnel change occurs after initial submission of qualifications and resume, an amendment to the Quality Control Plan shall be submitted to Document Control including required information List of Deliverables, Responsible Persons, Completion Dates Provide a list of design submittals, individuals responsible for specific roles and completion dates Plan Design Review Process Provide all necessary detailed elements of the design review process including report, calculation, design and specification checking protocols (Track changes in Microsoft Word to be maintained). Specify detailed procedure for checking, revising and reviewing markups. Describe the manner by which the plans will be checked. For example, RED markings by the Checker, BLUE by the Back Checker, YELLOW by the Corrector and GREEN by the verifier. Maintain and organize all plan markups for future audits. Complete the Quality Control Check Process Form for each deliverable. It is not necessary to submit the Quality Control Check Process Form with your design deliverable. MSDGC Designer Quality Control Plan Guidelines Page 6 of 14 7/09/2014
7 2.06 Document Control Include Design Consultant procedures for Document Control. Include management of project files (and s) for all members of the project team Sub Consultant Quality Control Describe the sub consultant s quality control process. Describe the Design Consultant s process to review sub consultant s work. Maintain a quality control log of the review of the sub consultant s work CAD Management Describe the CAD Management Strategy to coordinate the work of the prime and sub consultants so that MSDGC CAD Standards are followed (conveyance projects should follow MSDGC CAD Standards, treatment projects should follow the National CAD Standard) Schedule Management Describe the quality control process of the project schedule to ensure all project team members (including MSDGC Branches) concur with the time required for design, estimates, review, value engineering, etc Field Survey Quality Control Describe the field survey quality control process. Items to consider may include instrument calibration, crew experience, surveyor of record coordination, benchmark & datum, courthouse & monumentation research, utility research & marking, Civil 3D coordination, field book review and basemap preparation Quality Control Check Process Distribute the Quality Control Plan Acknowledgement Form to the key personnel listed in this plan to sign/date the form for acceptance of this project specific Designer Quality Control Plan. This form will follow your cover sheet for your QC Plan. MSDGC Designer Quality Control Plan Guidelines Page 7 of 14 7/09/2014
8 Section 3 Checklists & Forms The following checklists & forms are provided to establish a minimum level of quality control and shall be used as a basis for the development of the project specific checklists DESIGN Quality Control Checklist Project Name: Design Status: Project Number: FORMAT All drawings are the correct size. All drawings have been prepared with the required CAD software. Project titles are correct and consistent for all documents. Prescribed title blocks have been used. Line weights are correct. Text size and font style are correct. Process, mechanical, electrical and Instrumentation &Controls symbology are correct. Graphic scales are shown. Drawing numbering system is correct and consistent between disciplines. Specifications are in the correct format (MSDGC Detailed Provisions or CSI). Completion of MSDGC CAD Standard Plan Checklist. Completion of MSDGC CAD Standard Profile Checklist. Drawings sealed by Engineer of Record. FUNCTIONAL DESIGN Proposed systems and processes meet the stated performance objectives. Design reflects the most effective solution to meeting the design criteria. MSDGC directions from previous meetings and reviews have been incorporated. Design has been analyzed for problematic secondary effects. Level of complexity of the design is appropriate. Operating staffing level is appropriate. Maintenance and training burden is appropriate. Lessons learned are incorporated. All existing conditions are shown and field verified for accuracy. Existing buried utilities are verified by survey of field markings. Design is appropriate for chosen equipment and procurement methodology. Geotechnical recommendations included in the plans and specifications. MSDGC Designer Quality Control Plan Guidelines Page 8 of 14 7/09/2014
9 DESIGN Quality Control Checklist (Continued) CONSISTENCY Physical drawings agree with diagrammatic drawings. General arrangement drawings are consistent across disciplines. Plan views are consistent within disciplines and consistently oriented. Plan drawings are to a consistent scale. Sectional views are oriented consistently and sectional references are clear. Equipment list is complete and tag numbers are consistent and correct. Drawn elements are consistent across matchlines. Dimensioning and survey control are sufficient for layout and construction. Technical specifications are complete and in accordance with standards. Specification requirements are explicit where required. Functional and performance based specifications are used where appropriate. Preferred vendors are listed appropriately to optimize competition. CONSTRUCTABILITY Proposed site affords sufficient material laydown space. Utility review information included. Locations and depths of excavations are feasible. Shoring requirements are feasible. Proposed site affords sufficient access for equipment. Conventional equipment may be used for lifting and placement operations. Required field welding is accessible and can be performed as shown. Piping and equipment layouts allow sufficient room for assembly. Confined space entry requirements are identified. Site is amenable for multiple contractor access if applicable. Impacts of process outages are identified. Proposed construction sequence is described and understood across disciplines. Soil (Top of rock) information shown. Construction methods are consistent with the Geotechnical Baseline Report. MSDGC Designer Quality Control Plan Guidelines Page 9 of 14 7/09/2014
10 DESIGN Quality Control Checklist (Continued) CALCULATIONS Calculations include title, date, preparer s name and checker s name. Manual calculations are on computation paper in clear and legible print. Calculation pages are sequentially numbered. Record calculations bear the stamp of a qualified professional engineer, architect or surveyor as applicable. Assumptions and design criteria are listed. References to text books or technical papers are included as appropriate. Clarifying sketches, maps or diagrams are included. Computer software is identified by name and revision date. Input and output data are clearly indicated. Computer calculations include a narrative of the computational process. Electronic versions of input and output files are provided. Calculations contain a summary of conclusions and results. Sealed by the Engineer of Record. MSDGC Designer Quality Control Plan Guidelines Page 10 of 14 7/09/2014
11 EASEMENT QUALITY CONTROL CHECKLIST Located on plans. PRINT DATE FOR DRAWING Property owner names. Parcel numbers. Transfer dates. Transfer references. PROPERTY OWNER INFORMATION Easement language block. Property owner signature block. Notary block. County Administrator block. Sewers Chief Engineer block. EASEMENT COMPONENTS MSD COMPONENTS Project name block. Project identification block. Township, Section, Range (Military Survey). Accession number. Construction accession reference. Take area calculation tables. MSD CAD standards followed. PDF only submitted at review stages. MSDGC Designer Quality Control Plan Guidelines Page 11 of 14 7/09/2014
12 EASEMENT QUALITY CONTROL CHECKLIST (Continued) SURVEY COMPONENTS CL sewer easement property corner references. Metes & bounds easement references. Property line references. Easement take area references. Survey stamp & signature. Basis of bearings at north arrow. Topo and buildings not displayed. MSDGC Designer Quality Control Plan Guidelines Page 12 of 14 7/09/2014
13 Quality Control Sign Off Form for Design Submittals Project Name: Design Status: Project Number: Deliverable to be Checked: QA Manager (Print Name) Signature Date Engineer of Record (Print Name) Signature Date Project Team Design Lead (Print Name) Signature Date Checker (Print Name) Signature Date Back Checker (Print Name) Signature Date Corrector (Print Name) Signature Date Verifier (Print Name) Signature Date MSDGC Designer Quality Control Plan Guidelines Page 13 of 14 7/09/2014
14 QC Verification Letter Example <Date> Wastewater Engineering Building MSDGC Document Control 1035 Woodrow Street Cincinnati, Ohio Attention: <Project Manager> Re: <Project Number> <Project Name> Task Order Number <TO Number> <X%> Design Submission QC Verification Dear <Project Manager>: <Consultant> has performed a quality control review of the above referenced documents for the subject project. This review is in accordance with the QC Plan reviewed and approved by MSDGC Quality Assurance. If you have questions or comments, please feel free to contact me. Sincerely, <Consultant> <Consultant Project Manager Signature> <Consultant Project Manager> Senior Project Manager MSDGC Designer Quality Control Plan Guidelines Page 14 of 14 7/09/2014
SECTION 01 78 29 AS-BUILT DOCUMENTATION
SECTION 01 78 29 AS-BUILT DOCUMENTATION PART 1: GENERAL 1.01 AS-BUILTS Where identified as a product of the Work, provide as-built drawings adhering to the criteria provided here and in the special conditions.
CQR-1 CONTRACTOR QUALITY REQUIREMENTS for CONSTRUCTION SERVICES
1.0 SCOPE CQR-1 CONTRACTOR QUALITY REQUIREMENTS for CONSTRUCTION SERVICES This document establishes the minimum quality program requirements for a contractor providing equipment, material, and construction
Haulsey Engineering, Inc. Quality Management System (QMS) Table of Contents
Haulsey Engineering, Inc. Quality Management System (QMS) Table of Contents 1.0 Introduction 1.1 Quality Management Policy and Practices 2.0 Quality System Components 2.1 Quality Management Plans 2.2 Quality
UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Civil. Topographical Survey. Design Evaluation. Construction Submittals
This section applies to design standards and procedures involved in the field location and plotting of all natural objects and surface improvements. This section also includes the requirements for submittal
Capital Project Closeout. Construction Documentation Requirements
Capital Project Closeout Construction Documentation Requirements Guidelines for Architects, Contractors, and Project Managers For further information about this document contact: HARVARD UNIVERSITY PROPERTY
VDOT GOVERNANCE DOCUMENT
VDOT GOVERNANCE DOCUMENT Minimum Requirements for Quality Assurance and Quality Control on Design Build and Public-Private Transportation Act Projects Location and Design Division Alternate Project Delivery
Appendix A Contractor Quality Control Plan The Contractor Quality Control Plan is the Contractor s management plan for executing the contract.
Appendix A Contractor Quality Control Plan The Contractor Quality Control Plan is the Contractor s management plan for executing the contract. The Contractor QCP describes the way in which the Contractor
SCRRA Design Quality Assurance Plan
SCRRA Design Quality Assurance Plan JUNE 2015 (PAGE INTENTIONALLY LEFT BLANK) TABLE OF CONTENTS 1.0 FORWARD... 1 1.1 PURPOSE... 1 1.2 CHANGES/UPDATES... 1 1.3 ACRONYMS... 1 1.4 DEFINITIONS... 2 2.0 SOUTHERN
PIPING DRAWINGS BASICS N.P.TODKAR
PIPING DRAWINGS BASICS N.P.TODKAR There are two types of views used in the piping drawings: a) Orthographic- Plans and Elevations b) Pictorial - Isometric Views Piping layout is developed in both plan
SECTION 5 DRAFTING STANDARDS
SECTION 5 DRAFTING STANDARDS 1 SECTION FIVE TABLE OF CONTENTS Description Page TABLE OF CONTENTS... 5-2 GENERAL... 5-3 DRAFTING STANDARDS... 5-5 DRAFTING MINIMUM REQUIREMENTS HANDOUT... 5-8 2 GENERAL 1.
Quality Assurance QUALITY ASSURANCE PLAN
Revision 2 Page 1 of 40 QUALITY ASSURANCE PLAN PLAN APPROVALS: Jeff Shouse Signature on File DIRECTOR OF QUALITY ASSURANCE DIRECTOR OF QUALITY ASSURANCE (signature) DATE Rodney Baltzer Signature on File
CHECKLIST TO DESIGNATE AREAS OF EVALUATION FOR REQUESTS FOR PROPOSAL (RFP)
Michigan Department Of Transportation 5100B (05/13) CHECKLIST TO DESIGNATE AREAS OF EVALUATION FOR REQUESTS FOR PROPOSAL (RFP) Page 1 of 2 REQUISITION NUMBER DUE DATE TIME DUE MDOT PROJECT MANAGER JOB
Quality Control and Quality Assurance Guide
Quality Control and Quality Assurance Guide Bridge Division, Design Section October 2013 Table of Contents Chapter 1 About this Guide... 3 Chapter 2 Goals and Objectives... 5 Chapter 3 Participants...
LOUISIANA DEPARTMENT OF TRANSPORTATION AND DEVELOPMENT CONSTRUCTION PLANS QUALITY CONTROL / QUALITY ASSURANCE MANUAL
LOUISIANA DEPARTMENT OF TRANSPORTATION AND DEVELOPMENT CONSTRUCTION PLANS QUALITY CONTROL / QUALITY ASSURANCE MANUAL August 2008 TABLE OF CONTENTS Section 1 - Introduction... 3 1.1 Defining Plan Quality...
ISO 9001: 2008 Construction Quality Management System Sample - Selected pages (not a complete plan)
ISO 9001: 2008 Construction Quality Management System Sample - Selected pages (not a complete plan) Part 1: Project-Specific Quality Plan Part 2: Company Quality Manual Part 3: Submittal Forms Part 4:
Electronic Plan Submittal Application Process
Electronic Plan Submittal Application Process 1. Complete the appropriate Permit Application and associated checklist. 2. If applicable, complete the Single Family Cover Sheet. 3. Prepare your drawings
Animal Health Center for Reid Park Zoo, Tucson, Arizona
Reid Park Zoological Society Request for Qualifications Professional Architectural and Engineering Services for Animal Health Center for Reid Park Zoo, Tucson, Arizona SUBMITTAL DUE DATE: March 21, 2014
Brevard County Public Works Finance and Contracts Administration
Brevard County Public Works Finance and Contracts Administration Public Works Survey & Mapping Division Review Check Sheet for Land Acquisition, Drainage, Roadway and Pedway Expansion, Asbuilts, Maintenance
Section 100 Contractor Quality Control Program
7/21/2014 AC 150/5370-10G Section 100 Contractor Quality Control Program 100-01 General. When the specification requires a Contractor Quality Control Program, the Contractor shall establish, provide, and
G.S. 47-30 Mapping Requirements for Recordable Maps
G.S. 47-30 Mapping Requirements for Recordable Maps 47-30. Plats and subdivisions; mapping requirements. (a) Size Requirements. All land plats presented to the register of deeds for recording in the registry
REQUEST FOR PROPOSALS FOR CONSTRUCTION MANAGEMENT AT-RISK FOR LOGANVILLE ELEMENTARY SCHOOL (REPLACEMENT) FOR THE WALTON COUNTY SCHOOL DISTRICT
ADVERTISEMENT: REQUEST FOR PROPOSALS FOR CONSTRUCTION MANAGEMENT AT-RISK FOR LOGANVILLE ELEMENTARY SCHOOL (REPLACEMENT) FOR THE WALTON COUNTY SCHOOL DISTRICT The WALTON COUNTY SCHOOL DISTRICT will receive
Change Management Plan Template
Change Management Plan Template Project Name: U.S. Department of Housing and Urban Development October, 2010 Change Management Plan Template (V1.0) Notes to the Author [This document is a template of a
Design Consultant Project Management Requirements
Design Consultant Project Management Requirements Version 2 April 25, 2013 AWTP Program Design Consultant Contents 1.0 Introduction... 1 2.0 General Management... 1 3.0 Project Management Plan... 1 4.0
CAD Standards Guideline For Facility Documentation and Construction Projects
CAD Standards Guideline For Facility Documentation and Construction Projects Page 1 of 12 Table of Contents A. Software B. CAD Methods 1. Layer Standards 2. Font 3. Lineweights 4. External References 5.
Construction Management Program
Use and Limitation: The Sponsor may use this document as a guide in preparing a construction management program for their specific project. Sponsors and Consultants are cautioned that the provision of
QUALITY MANUAL ISO 9001. Quality Management System
Page 1 of 20 QUALITY MANUAL ISO 9001 Quality Management System Printed copies are not controlled unless marked "CONTROLLED". Upon receipt of this document, discard all previous copies. Page 2 of 20 Approval
Construction Management Standards of Practice
Construction Management Standards of Practice 2010 Edition Advancing Professional Construction/ Program Management Worldwide. 7926 Jones Branch Drive, Suite 800 McLean, VA 22102-3303 USA 703.356.2622 703.356.6388
Superconducting Magnet Division
Magnet Division Specification Specification Number: SMD-MAG-1001 Superconducting Magnet Division Revision: A Procedure for Preparation and Processing of ECR/ECN Prepared by: Design Group Supervisor: Production
CITY OF POWAY REQUEST FOR PROPOSALS (RFP) FOR GEOGRAPHIC INFORMATION SYSTEM (GIS) WATER / WASTEWATER SYSTEM DATA CONVERSION PROJECT ADDENDUM SIX
CITY OF POWAY REQUEST FOR PROPOSALS (RFP) FOR GEOGRAPHIC INFORMATION SYSTEM (GIS) WATER / WASTEWATER SYSTEM DATA CONVERSION PROJECT ADDENDUM SIX In reference to the Request for Proposals for Geographic
Building Plans: Electronic Submission Process and Requirements
PLANNING AND BUILDING DEVELOPMENT MANAGEMENT Development Application Management System Building Plans: Electronic Submission Process and Requirements From 1 January 2015 the City of Cape Town s Planning
CAD Standards. Design Guidelines and Standards. June 2004. Office of the University Architect
Design Guidelines and Standards CAD Standards June 2004 Office of the University Architect Construction Management P.O. Box 210181 Cincinnati, Ohio 45221-0181 Table of Contents Contents CAD STANDARDS Introduction...
BASE CONSTRUCTION INC
BASE CONSTRUCTION INC 14252 CULVER DRIVE A-630 IRVINE,CA 92604-0326 OFFICE:949 387-3471 Shop 714 994 9563 CELL:949 735-5292 FAX:949 786-8753 QUALITY ASSURANCE and QUALITY CONTROL MANUAL 1 TABLE OF CONTENTS
REQUEST FOR PROPOSAL CONSTRUCTION MANAGEMENT SERVICES
REQUEST FOR PROPOSAL CONSTRUCTION MANAGEMENT SERVICES Big Rapids Public Schools Building Program 2005 OWNER Big Rapids Public Schools 21034 15-Mile Road Big Rapids, Michigan 49307 PHONE: (231) 796-2627
Quality Assurance/Quality Control Plan. Division of Transportation Solutions
Quality Assurance/Quality Control Plan Division of Transportation Solutions January 2009 Table of Contents MISSION STATEMENT 3 GENERAL POLICY 3 QA/QC RESPONSIBILITIES 4 PROJECT DESIGNER 4 DELDOT S PROJECT
Design Deliverables Checklist
S a n i tary Sewer Overflow (SSO) Control a n d Wastewater Facilities Program Deliverables Checklist City of Baton Rouge/Parish of East Baton Rouge Department of Public Works Submitted by Prepared by:
Software Project Management Plan (SPMP)
Software Project Management Plan (SPMP) The basic template to be used is derived from IEEE Std 1058-1998, IEEE Standard for Software Project Management Plans. The following is a template for the SPMP.
CAD Standards Guideline For Facility Documentation and Construction Projects
CAD Standards Guideline For Facility Documentation and Construction Projects Implemented March 2010 Page 1 of 9 Table of Contents A. Software B. CAD Methods 1. Layer Standards 2. Font 3. Lineweights 4.
SCOPE OF WORK FOR PERFORMING INTERNAL CONTROL AND STATUTORY/REGULATORY COMPLIANCE AUDITS FOR RECIPIENTS OF SPECIAL MUNICIPAL AID
SCOPE OF WORK FOR PERFORMING INTERNAL CONTROL AND STATUTORY/REGULATORY COMPLIANCE AUDITS FOR RECIPIENTS OF SPECIAL MUNICIPAL AID State of New Jersey Department of Community Affairs Division of Local Government
MEAT GRADING AND CERTIFICATION BRANCH QUALITY MANUAL
United States Department of Agriculture Marketing and Regulatory Programs Agricultural Marketing Service Livestock and Seed Program Meat Grading & Certification Branch MGC Instruction 800 May 9, 2005 Page
1.0 INTRODUCTION 1.1 Overview
Guidance document for the writing of standard operating procedures (Taken from United States Environmental Protection Agency Guidance for Preparing Standard Operating Procedures (SOPs) EPA QA/G- 6 [EPA/600/B-
STATE OF NEW HAMPSHIRE APPLICATION FOR LICENSURE AS A LAND SURVEYOR. $120.00 Application Fee. 1. General lnformation
STATE OF NEW HAMPSHIRE APPL# For Office Use Only APPLICATION FOR LICENSURE AS A LAND SURVEYOR $120.00 Application Fee The application must be filled out completely and typewritten Check Payable to Treasurer,
Develop Project Charter. Develop Project Management Plan
Develop Charter Develop Charter is the process of developing documentation that formally authorizes a project or a phase. The documentation includes initial requirements that satisfy stakeholder needs
TROUP COUNTY COMPREHENSIVE HIGH SCHOOL
TROUP COUNTY BOARD OF EDUCATION REQUEST FOR SEALED COMPETITIVE PROPOSALS FOR CONSTRUCTION OF: RE-FLOORING TO: TROUP COUNTY COMPREHENSIVE HIGH SCHOOL LAGRANGE, GEORGIA TROUP COUNTY SCHOOL SYSTEM LAGRANGE,
RESIDENTIAL REAL ESTATE AGENT SERVICES FOR NEIGHBORHOOD STABILIZATION PROGRAM
Mark A. Cowart Chief Information Officer DEPARTMENT OF ADMINISTRATIVE SERVICES PURCHASING 2222 M Street Merced, CA 95340 (209) 385-7331 (209) 725-3535 Fax www.co.merced.ca.us Equal Opportunity Employer
Spec. Standard: 11/27/06 01310-1 Revision: 11/27/06
SECTION 01310 CONSTRUCTION SCHEDULES PART 1 - GENERAL 1.01 SCOPE: A. Construction Progress Schedule: The CONTRACTOR shall submit a detailed work progress schedule showing all work in a graphic format suitable
Professional Engineers Using Software-Based Engineering Tools
GUIDELINE Professional Engineers Using Software-Based Engineering Tools CONTRIBUTORS Eric Brown, P. Eng. Colin Cantlie, P. Eng. Norm Fisher, P. Eng. Jeremy Jackson, P. Eng. Tibor Palinko, P. Eng. Daniel
Independent Third-Party Review Guidelines
Colorado Division of Water Resources Dam Safety Branch Independent Third-Party Review Guidelines Policy Memorandum No. 01-03 February 10, 2003 1.0 INTRODUCTION Colorado Statutes (C.R.S. 37-87-105) require
REQUEST FOR QUALIFICATIONS
A. Instructions for the Request of Qualifications 1. Interested professional services are invited to submit one (1) comprehensive Statement of Qualifications (SOQ) by responding to the items below. Responses
Request for Proposals PROFESSIONAL SERVICES FOR DRINKING WATER, WASTEWATER AND STORMWATER PROJECTS OPEN-END CONTRACTS 2016-18
Request for Proposals PROFESSIONAL SERVICES FOR DRINKING WATER, WASTEWATER AND STORMWATER PROJECTS OPEN-END CONTRACTS 2016-18 Page 2 of 8 1. INTRODUCTION Capital Region Water (CRW) is requesting proposals
REQUEST FOR PROPOSALS CENTRAL NEW YORK ECONOMIC DEVELOPMENT REAL ESTATE SITE PROFILE DATA BASE SYRACUSE, NEW YORK MARCH 25, 2013
REQUEST FOR PROPOSALS CENTRAL NEW YORK ECONOMIC DEVELOPMENT REAL ESTATE SITE PROFILE DATA BASE SYRACUSE, NEW YORK MARCH 25, 2013 CENTRAL NEW YORK REGIONAL PLANNING AND DEVELOPMENT BOARD 126 NORTH SALINA
Project Management Plan for
Project Management Plan for [Project ID] Prepared by: Date: [Name], Project Manager Approved by: Date: [Name], Project Sponsor Approved by: Date: [Name], Executive Manager Table of Contents Project Summary...
RESIDENTIAL ON-SITE WASTEWATER TREATMENT SYSTEM (OWTS) INSTALLATION PERMIT (New or Repair) Instructions and Application Form
DEPARTMENT OF PUBLIC HEALTH AND ENVIRONMENT 1555 North 17 th Avenue Greeley, CO 80631 Web: www.weldhealth.org Health Administration Vital Records Tele: 970.304.6410 Fax: 970.304.6412 Public Health & Clinical
Checklist 26: How Owners Can Avoid Litigation on Construction Projects
Checklist 26: How Owners Can Avoid Litigation on Construction Projects While it is impossible to completely avoid litigation on construction projects, certain steps can be taken to minimize the potential
San Antonio Water System Standard Specifications for Construction ITEM NO. 903 CONSTRUCTION QC/QA PROGRAM
ITEM NO. 903 CONSTRUCTION QC/QA PROGRAM 903.1 DESCRIPTION: This item shall govern the preparation and implementation of the Contractor s Construction Quality Control/Quality Assurance (QC/QA) Program for
STATE OF ALASKA DEPARTMENT OF NATURAL RESOURCES DIVISION OF MINING, LAND AND WATER. GENERAL SURVEY INSTRUCTIONS EASEMENTS Authority 11 AAC 53
STATE OF ALASKA DEPARTMENT OF NATURAL RESOURCES DIVISION OF MINING, LAND AND WATER GENERAL SURVEY INSTRUCTIONS EASEMENTS Authority 11 AAC 53 These instructions define the survey and platting criteria unique
Guidelines for the Acceptance of Manufacturer's Quality Assurance Systems for Welding Consumables
(1987) Guidelines for the Acceptance of Manufacturer's Quality Assurance Systems for Welding Consumables 1. General 1.1 Introduction 1.1.1 The present guidelines are to serve as a supplement to the IACS
REQUEST FOR PROPOSALS ( RFP ) FOR FINANCIAL ADVISOR TO IMPLEMENT USE AGREEMENT(S) PROCESS AS DESCRIBED IN STRATEGIC AND CAPITAL NEEDS STUDY
REQUEST FOR PROPOSALS ( RFP ) FOR FINANCIAL ADVISOR TO IMPLEMENT USE AGREEMENT(S) PROCESS AS DESCRIBED IN STRATEGIC AND CAPITAL NEEDS STUDY Required for use by: Illinois International Port District (IIPD)
Quality Manual. This manual is proprietary and no part thereof shall be copied without written authorisation from the company. Ref: Quality Manual.
This manual is proprietary and no part thereof shall be copied without written authorisation from the company Ref: Quality Manual.ind Issue: June 2009 INDEX 1 Amendment Status 2 Controlled Distribution
REQUEST FOR QUALIFICATIONS
Qualification packets and updates will be accepted at, Mitchell Elementary 1350 E. 33 rd Ave. Denver, CO. 80205, until January 3, 2013 at 2:00 PM Local Denver Time. Attn: Strategic Sourcing/ Department.
REQUEST FOR QUALIFICATIONS FOR CONSTRUCTION MANAGER-AT-RISK (CMAR)
REQUEST FOR QUALIFICATIONS FOR CONSTRUCTION MANAGER-AT-RISK (CMAR) For the Project: CITY OF KATY NEW KATY FIRE STATION #2 Issued: August 13, 2015 Katy Fire Station #2 August 13, 2015 Page 1 of 17 Request
SUPPLIER QUALITY SYSTEM AUDIT
Company Name: Date: Company Address: Quality Assurance Mgr: President: Number of employees: Is your company receptive to source inspection? List all standards the quality system is based on Web Page: Company
Software Quality Subcontractor Survey Questionnaire INSTRUCTIONS FOR PURCHASE ORDER ATTACHMENT Q-201
PURCHASE ORDER ATTACHMENT Q-201A Software Quality Subcontractor Survey Questionnaire INSTRUCTIONS FOR PURCHASE ORDER ATTACHMENT Q-201 1. A qualified employee shall be selected by the Software Quality Manager
CITY OF JERSEY CITY REQUEST FOR PROPOSALS: AUDITING SERVICES: FORENSIC AUDIT OF FINANCIAL ACTIVITIES OF PROPERTY OWNER GRANTED PILOT AGREEMENT
CITY OF JERSEY CITY REQUEST FOR PROPOSALS: AUDITING SERVICES: FORENSIC AUDIT OF FINANCIAL ACTIVITIES OF PROPERTY OWNER GRANTED PILOT AGREEMENT SUBMISSION DEADLINE: 4:00 p.m. November 13, 2013 ADDRESS ALL
Standard Practice for Quality Control Systems for Nondestructive Testing Agencies 1
Designation: E 1212 99 AMERICAN SOCIETY FOR TESTING AND MATERIALS 100 Barr Harbor Dr., West Conshohocken, PA 19428 Reprinted from the Annual Book of ASTM Standards. Copyright ASTM Standard Practice for
Classification Appeal Decision Under Section 5112 of Title 5, United States Code
U.S. Office of Personnel Management Office of Merit Systems Oversight and Effectiveness Classification Appeals and FLSA Programs Washington Oversight Division 1900 E Street, NW Washington, DC 20415 Classification
REQUEST FOR PROPOSAL FOR GENERAL CONTRACTOR FOR AFFORDABLE MULTI-FAMILY HOUSING BREVARD COUNTY, FLORIDA. Issue Date: March 10, 2015
REQUEST FOR PROPOSAL FOR GENERAL CONTRACTOR FOR AFFORDABLE MULTI-FAMILY HOUSING BREVARD COUNTY, FLORIDA Issue Date: March 10, 2015 CLOSING DATE: Tuesday, March 31st, 2015, 2:00 p.m. EST Housing Authority
Construction Management Services Delmar School District RFP No. DSD16001-CONSTR_MAN
Construction Management Services Delmar School District RFP No. DSD16001-CONSTR_MAN The Delmar School District (DSD) is seeking the professional services of a Construction Management (CM) firm for the
SAMPLE. CONTRACT FOR PROFESSIONAL SERVICES: Lump Sum by Phase. Federal Identification (I.D.) Number
Lump Sum A/E R 12/16/13 STATE OF MICHIGAN DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET This contract authorizes the professional services contractor to provide professional services. (Authority: 1984
Template K Implementation Requirements Instructions for RFP Response RFP #
Template K Implementation Requirements Instructions for RFP Response Table of Contents 1.0 Project Management Approach... 3 1.1 Program and Project Management... 3 1.2 Change Management Plan... 3 1.3 Relationship
Applicant. User Guide. www.beverlyhills.org/electronicreview
Applicant User Guide Quick References Page 2 Table of Contents Page 3 How to submit eplans. Page 7 Preparing eplans. Page 9-10 eplan File Names. Page 18 Resubmit Plans. www.beverlyhills.org/electronicreview
CORPORATE QUALITY MANUAL
Corporate Quality Manual Preface The following Corporate Quality Manual is written within the framework of ISO 9001:2008 Quality System by the employees of CyberOptics. CyberOptics recognizes the importance
Request for Qualifications for Program Management Support Services for The Greenville-Spartanburg International Airport Terminal Improvement Program
Request for Qualifications for Program Management Support Services for The Greenville-Spartanburg International Airport Terminal Improvement Program SECTION 1 - GENERAL INFORMATION The Greenville-Spartanburg
Independent School District No. 1 Strive Achieve Succeed Go Beyond Lewiston, Idaho
Independent School District No. 1 Strive Achieve Succeed Go Beyond Lewiston, Idaho REQUEST FOR QUALIFICATIONS Independent School District No. 1, Lewiston, Idaho ( District ) is seeking responses from individuals
Project Management Manual Update 2006. Transportation Department City of Edmonton
Project Management Manual Update 2006 Transportation Department City of Edmonton Project Management Manual for Transportation Projects EXECUTIVE SUMMARY This document has been updated to fulfill the requirements
ISO 9001:2008 STANDARD OPERATING PROCEDURES MANUAL
8200 Brownleigh Drive Raleigh, NC 27617-7423 Phone: (919) 510-9696 Fax: (919) 510-9668 ISO 9001:2008 STANDARD OPERATING PROCEDURES MANUAL ALLIANCE OF PROFESSIONALS & CONSULTANTS, INC. - 1 - Table of Contents
Quality Management System Manual
Quality Management System Manual This manual has been reviewed and approved for use by: Jack Zazulak President, Aurora Machine Limited March 07, 2011 Date - Copyright Notice - This document is the exclusive
REQUEST FOR PROPOSALS FOR DISASTER RECOVERY ADMINISTRATIVE SERVICES
REQUEST FOR PROPOSALS FOR DISASTER RECOVERY ADMINISTRATIVE SERVICES Notice is hereby given that the Santa Rosa County Board of County Commissioners is calling for and requesting proposals from qualified
Energy Design Resources Commissioning Plan Outline Template
IMPORTANT NOTICE: This sample document is provided for instructional purposes only. CCC is not rendering advice concerning any commission project or practices. This document is neither approved nor intended
GUIDELINES FOR AUGUST 1995
GUIDELINES FOR ELECTRICAL ENGINEERING SERVICES AUGUST 1995 PUBLISHED BY: PROFESSIONAL ENGINEERS AND GEOSCIENTISTS OF NEWFOUNDLAND & LABRADOR (PEGNL) P.O. Box 21207, St. John's, NL A1A 5B2 Telephone: (709)
How to implement a Quality Management System
How to implement a Quality Management System This whitepaper will help you to implement a Quality Management System (QMS), based on Good Manufacturing Practice (GMP), ISO 9001 or ISO 13485 within your
QUALITY MANAGEMENT SYSTEM MANUAL
The online version of this document is controlled. Therefore, all printed versions of this document are unofficial copies. QUALITY MANAGEMENT SYSTEM MANUAL 6901 Charles Street Towson, Maryland 21204 Manual
Contract Administration
Chapter 5 Contract Administration Section 3 Change Orders 5-301 General 5-302 Change Order Policy 5-303 Purpose of Change Orders 5-304 Initiation of Change Orders 5-305 Preliminary Considerations 5-306
A/E Consultant Handbook Engineering Department. Facilities Engineering Services Section April 2008
A/E Consultant Handbook April 2008 The primary objective at Fermilab is that operations be conducted in a safe, deliberate and controlled manner. The role of the FESS/E procedures is to provide the best
THIS PAGE INTENTIONALLY LEFT BLANK
Facilities Management June 29, 2015 THIS PAGE INTENTIONALLY LEFT BLANK Page 2 of 31 CAD Guidelines and Standards Table of Contents SECTION 1: THE PURPOSE OF USING CAD DATA STANDARDS... 5 1.1 Industry Standards...
QUOTE OPENING MEETING: Sealed Quotes will be opened at 9:00 a.m (eastern standard time) on Wednesday, May 1, 2013 at the County of Muskegon.
COUNTY OF MUSKEGON REQUEST FOR QUOTES (RFQ) FOR PROFESSIONAL REAL ESTATE SERVICES The County of Muskegon, through its County Administration Department, Office of Grant Services, is seeking contractors
Quality Process in Engineering ISO 9000 and Beyond. Presented by: Roxanne L. Pillar, P.E. October 2014
Quality Process in Engineering ISO 9000 and Beyond Presented by: Roxanne L. Pillar, P.E. October 2014 Good morning Introductions: Quality Management Systems (QMS) What are they? Where do they come from?
LANSING COMMUNITY COLLEGE 14205.00 TLC BUILDING SERVER ROOM UPGRADES SECTION 013300 - SUBMITTAL PROCEDURES PART 1 - GENERAL 1.
SECTION 013300 - SUBMITTAL PROCEDURES PART 1 - GENERAL 1.1 SUMMARY A. Section includes requirements for the submittal schedule and administrative and procedural requirements for submitting Shop Drawings,
Quick Reference Guide Interactive PDF Project Management Processes for a Project
Project Processes for a Project Click the Knowledge Area title (below and left in blue underline) to view the details of each Process Group. Project Process Groups and Knowledge Areas Mapping Project Process
PROJECT CONTROL PROCEDURE (PROJECT STANDARDS AND SPECIFICATIONS)
TABLE OF CONTENTS Page 1 of 18 PURPOSE 2 SCOPE 2 DEFINITION 2 ORGANIZATION AND RESPONSIBILITIES 2 Organization and Function 2 Integration of Control Functions 5 7 Introduction 7 Planning and Scheduling
Quality Manual TABLE OF CONTENTS APPROVAL SIGNATURE PAGE 1.1 1 AMENDMENT RECORD 1.2 2 SCOPE 2.0 3 EXCLUSIONS 2.1 3
TABLE OF CONTENTS DESCRIPTION SECTION PAGE INTRODUCTION 1.0 1 APPROVAL SIGNATURE PAGE 1.1 1 AMENDMENT RECORD 1.2 2 SCOPE 2.0 3 EXCLUSIONS 2.1 3 CORPORATE POLICY 3.0 3 QUALITY MANAGEMENT SYSTEM 4.0 4 GENERAL
DEVELOPMENT OF BEST MANAGEMENT PRACTICES TO EXECUTE A SUCCESSFUL CAPITAL IMPROVEMENT PROGRAM
DEVELOPMENT OF BEST MANAGEMENT PRACTICES TO EXECUTE A SUCCESSFUL CAPITAL IMPROVEMENT PROGRAM 2015 Business Plan Chapter 3, Water Facilities Focus Area, Goal Number 4 June 2011 CAPITAL IMPROVEMENT PROGRAM
INSTRUCTIONS TO OFFERORS
INSTRUCTIONS TO OFFERORS Date To: CIO-SP3 Qualified Offerors From: US Technology Agency Subject: Request for Proposal (RFP) Project No. 12345, IT Enterprise-Wide Systems Support The Agency is issuing this
Overview of Land Construction Courses at Kansas State University
Overview of Land Construction Courses at Kansas State University Developed by Professor Day in the mid 1960 s at KSU, continuing to present time, is a vision of a Land Construction course series that examines
{ { { Meeting Date 08/03/10. City of Largo Agenda Item 24. Leland Dicus, P.E., City Engineer
City of Largo Agenda Item 24 Form Revision Date: 10/19/09: Meeting Date 08/03/10 Presenter: Leland Dicus, P.E., City Engineer Department: CD Community Development TITLE: GIS PROGRAM UPDATE The implementation