PUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL LINEAR INFRASTRUCTURE
|
|
|
- Adam Carr
- 10 years ago
- Views:
Transcription
1 REGION OF PEEL PUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL LINEAR INFRASTRUCTURE Sanitary Sewer Design Criteria REVISED July 2009
2 PUBLIC WORKS SANITARY SEWER DESIGN CRITERIA TABLE OF CONTENTS 1. INTRODUCTION Geotechnical Investigation DESIGN FLOWS Population Equivalents Based on Land Use Peak Sanitary Flow Factor Infiltration Design Flows PIPE SIZE Pipe Classification FLOW VELOCITIES PIPE SELECTION AND DESIGN Sewer Pipes and Appurtenances Rigid Pipe Design Flexible Pipe Design Deflection Calculations PIPE DEPTH, LOCATION AND BEDDING Pipe Depth Location Bedding Easements MAINTENANCE HOLES... 14
3 8. SEWER LATERALS Residential Commercial Industrial Connection Protocol NON-PERMITTED USES Appendix Std. Dwg Std. Dwg Std. Dwg Std. Dwg Std. Dwg Std. Dwg Std. Dwg Std. Dwg Std. Dwg Flow Calculation Sheet Domestic Flow Chart Circular Drain Nomograph Discharge and Velocity Partially Full Pipe Flow Chart Pipe Class Requirements Concrete Pipe Deleted Computation Diagram For Soil Load on Trench Installation Values of B d /B c
4 Page: 1 1. INTRODUCTION The design of municipal services in the Region of Peel is to be based upon the current Public Works Design, Specification & Procedures Manual. All plans are to be reviewed by the Region prior to the construction of services. Such review shall not relieve the engineer from primary responsibility for the design to meet all Federal, Provincial, Regional, and local government requirements. Refer to the Environmental Assessment Process section of this manual for the steps required to fulfill the Class Environmental Assessment process Geotechnical Investigation The Consultant shall determine the need for soils investigation. However, if Regional staff requests a geotechnical investigation, the Consultant must supply one. The purpose of a geotechnical investigation would be to determine the soil s composition, bearing strength, and type, and to verify that no contamination is present; which would be determined by the consultant. The consultant shall recommend the appropriate bedding requirements based on the findings of the geotechnical investigation and state them on the drawings. Boreholes shall be taken to a minimum depth of one (1) metre below the anticipated depth of the sanitary sewer invert.
5 Page: 2 2. DESIGN FLOWS Design calculations for sanitary sewer systems shall be completed on Standard Drawing (appended hereto) Population Equivalents based on Land Use Residential Population equivalent densities are to be calculated based upon the following criteria: Density Single family (greater than 10m frontage) Single family (less than 10m frontage) Semi-detached Row dwellings Apartments Pop./Hectare 50 persons/hectare 70 persons/hectare 70 persons/hectare 175 persons/hectare 475 persons/hectare Apartments If the proposed population equivalent is greater than 475 persons/hectare, based on a rate of 2.7 people per unit (ppu), then the calculated population equivalent shall be used for design. 2.7 ppu x (# units) = pop/hectare area Standard Drawing (appended hereto) lists domestic sewage flows versus population including a peaking factor. Industrial For light industrial areas, use an equivalent population of 70 persons per hectare. Refer to Standard Drawing for sanitary sewage flows. Individual studies are to be made for special industries and major industrial areas.
6 Page: 3 Commercial For commercial areas, use an equivalent population of 50 persons per hectare. Refer to Standard Drawing for sanitary sewage flows. Individual studies are to be made for infill commercial development, redevelopment, land use intensification and areas where the equivalent population will be greater than 50 persons per hectare. Institutional Equivalent population per site as follows: Junior Public Schools 1/3 x number of students (600 students minimum) Senior Public Schools ½ x number of students (900 students minimum) Secondary Schools 2/3 x number of students (1,500 students minimum) Hospitals Apply a population equivalent of 3 persons per bed Peak Sanitary Flow Factor The peak sanitary flows in Standard Drawing were derived by applying the ratio established by the Harmon Formula to the average day sanitary flows as follows: 14 M = p where: M = ratio of peak flow to average flow P = the tributary equivalent population in thousands
7 Page: Infiltration Except for unusual circumstances, the infiltration portion of sewage flow shall be m 3 /sec/ha for all types of land use. This factor applies to the gross area of all lands. When designing sewers that accept flows from an area developed more than twenty five (25) years ago, or where evidence indicates, an additional allowance shall be made for foundation drains equal to 0.08 litres/sec/foundation drain ( m 3 /sec/drain). Additional allowance for maintenance hole inflow: m 3 /sec/mh or equivalent of m 3 /sec/m of sewer length shall be included Design Flows Design flows shall be based upon the equivalent population from Standard Drawing (peaking factor included). To this figure an infiltration allowance is added based upon the gross area. See section 2.3 above. Minimum sewer pipe grades to be as per Standard Drawing
8 Page: 5 3. PIPE SIZE To determine pipe size and its capacity, refer to Standard Drawing (Circular Drain Nomograph), or use Manning s Formula, expressed as follows: A Q = 3 n R S where: Q = Design flow (m 3 /sec) n = Coefficient of Roughness R = Hydraulic Radius (m) (A F /P W ) S = Slope (m/m) A F = Area of Pipe Flowing Full P W = Wetted Perimeter A = Cross-Sectional Area of Pipe (m 2 ) The coefficient of roughness for all pipes shall be: n = The minimum pipe size shall be 250mm diameter. Refer to Standard Drawing (Discharge and Velocity) to select a pipe size vs. slope and to determine the resultant capacity and velocity. 3.1 Pipe Classification Primary Collection System Major Trunk Sewers larger than 750mm diameter, dedicated to the conveyance of wastewater between local Trunk Sewers and Wastewater Treatment Plants. Local Trunk Sewer Collection System Large diameter pipes, 375mm diameter to 675mm diameter, used to transmit wastewater from local sanitary sewers within subdivisions to the Primary Collection System. Local Collection System Pipes 250mm diameter to 300mm diameter in size, used to collect wastewater within subdivisions. See paragraph 8.4 for Connection Protocol.
9 Page: 6 4. FLOW VELOCITIES The flow velocities shall be determined from Standard Drawing or by Manning s Formula: V = Q A where: V = Flow velocity (m/sec) Q = Design flow (m 3 /sec) A = Cross sectional area of flow (m 2 ) The maximum flow velocity shall not be greater than 3.5 m/sec with the pipe flowing full and the minimum velocity shall not be less than 0.75 m/sec at actual flow. To determine sewage velocities based upon actual flow refer to Standard Drawing Values of Hydraulic Elements of a Circular Section for Various Depths of Flow. Use a minimum grade of 0.50% for sewers servicing less than 500 persons, except for the last leg of sewer where a minimum grade of 1.00% is required. Where depth is a problem, a 250mm diameter sewer at 0.40% grade can be used when servicing more than 500 persons up to the capacity of the sewer. Further, a 300mm diameter sewer at 0.35% grade can be used when servicing a minimum of 1,000 persons. Concrete pipe larger than 450mm diameter (including maintenance holes) where velocities are greater than 2.0 m/sec and drops across maintenance hole is greater than 0.3m shall be reviewed for protection against sulphuric acid (H 2 SO 4 ) and protected in a manner satisfactory to the Region of Peel.
10 Page: 7 5. PIPE SELECTION AND DESIGN 5.1. Sewer Pipes and Appurtenances Sewer pipes and appurtenances shall be in accordance with the current Manufactures Approved Products List, Sanitary Sewer and Appurtenances section of this manual Rigid Pipe Design Refer to Standard Drawings for pipe class requirements for rigid pipe. Special designs shall be completed in accordance with the following guidelines: Live Load For calculating transmitted live loads on sewer pipes, use Marston s Formula: W = 1. 0 L I C t C t where: W t = Average load per unit length of pipe (kg/linear metre) T L = Length of pipe (metres) on which the load is computed I c = Impact factor for a moving load C t = Load Coefficient T = A concentrated surface load (kg) For vehicular traffic, use loading in accordance with the Ontario Highways Bridge Design Code (OHBDC). For railroad traffic, use E-80 loading (1.75) or additional requirements per the respective rail road company.
11 Page: 8 Dead Load For calculating backfill loading on sewer pipes, use Marston s Formula: W d = C d W B 2 d W C = *For trench conditions (Standard Drawing 2-5-8) C C W B 2 C *For embankment conditions (Standard Drawing 2-5-9) where: W d = The soil backfill load in kg/linear metre W c = The soil backfill load in kg/linear metre C d = The load coefficient for trench condition C c = Coefficient (dimensionless) for positive projecting embankment condition (Standard Drawing 2-5-9) W = Unit weight of the backfill material in kg per metre 3 B d = Width of trench in metres, measured in a horizontal plane at the extreme top of the pipe Min. O.D. of the pipe +.45 m Max. O.D. of the pipe +.75 m B c = The O.D. of the pipe in metres For non-reinforced pipe, multiply the above loading by a factor of safety of The width of a trench at which a transition occurs between the trench condition and embankment condition can be determined by referring to Standard Drawing To determine the value of C c on Standard Drawing 2-5-9, the r sdp value is to be established. The term r sdp is made up of the projection ratio (P) and the settlement ratio ( r sd). These ratios form the shear component of the total load on a sewer under embankment conditions. If no other data are available, an r sdp ratio of 0.35 may be used.
12 Page: 9 Establish H/B c. Enter Standard Drawing to determine the ratio of B d /B c. Apply this ration to the OD of the pipe (B c ) to determine the installation conditions. The minimum A.S.T.M crack, three edge bearing strength requirements for reinforced concrete pipe and minimum A.S.T.M. three edge bearing crushing strength requirements for non-reinforced concrete pipe are to be used in determining pipe strength. Refer to Standard Drawing for standard pipe beddings and resultant load factors to determine field supporting strength Flexible Pipe Design Dead Load 1 P = WH 10,000cm 2 Where: P = Prism Load (kg/cm 2 ) Live Load W = Unit weight of the backfill soil (kg/m 3 ) H = Depth of cover (m) Live loads are calculated in the same manner as with rigid pipe (see section 5.2.).
13 Page: Deflection Calculations The maximum allowable deflection of PVC pipe under loadings shall be equal to 5% (five percent) of the nominal internal diameter, or as per 50% manufacturer s specifications. This percent deflection may be calculated using the following formula: Percent Deflection: % Y D = D K P 100 L 1 ( F ) + ( ) Y E Where: E 1 = Modulus of soil reaction (kpa) For main sewer line kpa For sanitary connections kpa D L = Deflection lag factor (1.50) K = Bedding constant (0.11) P = Prism Load WH x _1_ 10,000 cm 2 H = Depth of cover (m) W = Unit weight of backfill material (Min. 2,080 kg/m 3 ) F/ Y = Min kg/cm/cm
14 Page: PIPE DEPTH, LOCATION AND BEDDING 6.1. Pipe Depth The obvert of the sewer shall be a minimum of 2.5 m below the centre line of the road allowance. Where this is not possible, minimum basement elevations of 1.0 m above the sanitary pipe obvert are to be shown on the profile drawing, lot grading plans, and general underground servicing plan. These elevations are to be included in the Servicing Agreement. In commercial areas, the sewer obvert shall be a minimum of 3.5 m below the centre line of the road allowance where possible. In valleys, the sewer obvert shall be a minimum 1.4 m below the creek bottom. A permit from the Conservation Authority is required for creek crossing. In all cases the proposed sanitary sewers shall be installed at sufficient depth to service lands external to the site as determined by the Region of Peel. Special design consideration for water tight joints is to be applied when pipe is buried to a depth where significant hydrostatic pressures are anticipated. The Consulting Engineer shall support the selection of the type of pipe to be used with detailed design calculations, when requested Location The sanitary sewer shall be located 1.50 m north or east of the centreline of the road allowance unless conflicts with other utilities require a revised location. Curvilinear sewer alignments may be permitted for large diameter sewers only, provided it is parallel to the road centreline and compensation is provided for head losses due to curvature. A 2.0 m horizontal separation between the sanitary sewer and storm sewer (barrel to barrel) will be permitted to allow for common trench construction as long as the inverts of both sewers are at the same relative elevation. Should the sewer inverts vary by more than 1.0 m, a 3.0 m horizontal separation shall be maintained. Note: Allowance to be made for minimum basement elevation where storm sewers obvert impacts the serviceability of adjacent lands Bedding Sanitary sewers shall be installed with bedding as per Standard Drawing The sieve analysis for granular bedding materials can be seen in the standard drawings.
15 Page: 12 In rock and shale excavation, the Consultant shall determine the required thickness of compressible material (minimum 50mm layer) between the trench walls and any concrete encasement Easements No Regional infrastructure shall be installed in a trench whose lines of influence encroach on the foundation of any present or proposed permanent structure. Line of influence An imaginary line at a slope of 1:1 taken from the deepest point of the permanent structure towards the easement in question. The zone of influence would therefore be all areas underneath the lines(s) of influence. Easements for Region of Peel sanitary sewers with a pipe invert between 2.5m to 3.6 m depth require a total easement width of 8.0 m. The sanitary sewer should be offset within the easement as illustrated. STANDARD EASEMENT Easement Limit 3m SANITARY SEWER 8m 5m Easement Limit * Width adjustment required for pipes where O.D. > 0.5m * 1.7m to 3.6m depth Certain restrictions apply with respect to easements as per the documents registered on title. The applicant must keep the easement clear of buildings, structures, or obstructions. The permitted use for the easement lands are restricted to lawn, flowerbed, roadway, driveway or parking area which can
16 Page: 13 not be paved with a hard concrete surface. Maintenance vehicles and equipment must be able to easily access infrastructure in the easement. NON STANDARD/DUAL USE EASEMENT Easement Limit 3m 3m UTILITY, BY OTHERS O.D. SANITARY SEWER O.D. 0.5m 1.2m or 2.5m if sewer SANITARY SEWER O.D. 5m 1.2m or 2.5m if sewer WATERMAIN O.D. Easement Limit 3m A width adjustment is required for infrastructure with an outside diameter (O.D.) greater than 500 mm. Required easement width is directly related to pipes outside diameter. Example: for pipe with an outside diameter of 800mm, assuming standard depth of bury, the minimum easement width shall be 8.3m (3m + 5m + (800mm 500mm)) For Region of Peel infrastructure with a pipe depth greater than 3.6 m, the easement width shall be designed such that the infrastructure can be installed by conventional excavation methods with the operation totally contained within the easement limits. Furthermore, the pipe location within the easement should not be within the zone of influence of any existing or proposed permanent structure. Considerations need to be made to accommodate 1:1 slope above the shoring box (3.6m). For each metre of depth below 3.6m, the width of the easement will need to increase by 2m.
17 Page: MAINTENANCE HOLES All maintenance holes shall conform to the current Manufacturer s Approved Products List, Sanitary Sewer and Appurtenances, Standard Drawings to and designed according to the following criteria: a) The maximum spacing shall be 120 m between maintenance holes for sewers up to 600mm diameter. For sewers greater than 600mm diameter spacing up to 170 metres may be used. Large trunk sewers may use greater spacing at the Region s approval. b) Drops through sanitary maintenance holes shall be calculated using the following formula: Velocity Head = 2 V 2g 90 o bends = ½ Velocity Head 45 o bends = ¼ Velocity Head Where: g = 9.8 m/sec 2 On 250 mm to 300 mm diameter pipes: minimum drop = m maximum drop = 0.20 m On larger pipes, drops to be calculated as per the above. c) At maintenance holes where pipe sizes change, the above criteria shall be altered such that the obverts of the pipe are matched. d) Where depth from the invert to top of a maintenance hole exceeds 5.0 m, a safety platform is to be provided as per Regional Standard The platform shall be located to allow 2.0 m below manhole cover and 2.6 m above benching. e) Drop maintenance holes shall be provided where the difference in invert elevation is greater than 0.90 m. The drop pipe shall be one size smaller than the sewer line (minimum 250mm diameter). The economic feasibility of providing a deeper sanitary sewer instead of a drop maintenance hole shall be explored. The use of 45 o bends and Y s for drops is acceptable. No drops will
18 Page: 15 be accepted between 0.9 m and the requirements in 7(b) above. See Standard Drawings and f) Watertight bolt down covers shall be provided on maintenance holes located in all easements and in areas where maintenance holes are susceptible to flooding and/or vandalism. Where significant sections of sanitary sewers are provided with watertight covers, extended vents will be required at every third maintenance hole as per STD DWG The elevation of the vents shall be above Regional flood lines as determined by the appropriate Conservation Authority and illustrated on the plan and profile drawings. Where possible, maintenance holes shall be accessible to maintenance vehicles and equipment and be positioned in a suitable location to allow for venting. g) When a PVC sewer is installed into a maintenance hole, one of the following methods is to be used: i) Couplings providing an elastomeric gasket seal are to be grouted into the maintenance hole wall. ii) A manufactured length of PVC that has been softened with solvent and covered with sand for adherence to grout in the wall of the maintenance hole. h) Even when an elastomeric gasket is used at the maintenance hole wall, the maximum distance to the first joint from the maintenance hole wall when using PVC pipe shall be 0.60 m. Special care shall be taken in compacting the overexcavated area at the maintenance hole wall. As an alternative, concrete fill may be used to 100 mm below the sanitary invert. Standard bedding is then used for the remaining depth. i) 90 changes of flow direction should be eliminat ed, where possible, by utilizing 2 x 45 bends within maintenance holes.
19 Page: SEWER LATERALS 8.1. Residential All residential connections shall be in accordance with the current Manufacturer s Approved Products list, Sanitary Sewer/Forcemains. The minimum diameter within the road allowance shall be 125 mm. The minimum and maximum cover at street line shall be 2.30 m and 2.75 m respectively, unless circumstances require otherwise. If necessary, risers shall be provided for connection with the main sewer as per STD DWG to These risers are to be shown on the profile portion of the drawings. Grades of 1% minimum and 2% maximum shall be used for laterals. Connections directly into maintenance holes shall be minimized and reviewed on an individual basis Commercial In commercial areas, the minimum connection size shall be 150 mm in diameter, installed with a minimum grade of 1% and a maximum grade of 2%. The minimum cover at property line shall be 2.30 m, unless circumstances require otherwise. The maximum drop across the property line manhole shall be 0.03 m. The maximum depth is as required by design. A maintenance hole will be required if the lateral diameter is equal to or greater than half the diameter on the main line sewer, except for a 150 mm diameter pipe connecting to a 250 mm diameter mainline or a 200mm diameter pipe connecting to a 375 mm diameter (see matrix below). If necessary, risers shall be provided at the main sewer and shown on the profile drawings as per STD DWG to Connection numbers are to be established prior to construction of the lateral. Pipe materials shall be in accordance with the current Manufacturer s Approved Products List, Sanitary Sewer and Appurtenances Industrial The minimum connection size shall be 150 mm diameter, installed on a minimum grade of 1% and a maximum grade of 2%. The minimum and maximum cover at property line shall be 2.00 m and 2.75 m respectively, unless circumstances require otherwise. The maximum drop across the property line manhole shall be 0.03 m. A maintenance hole will be required if the lateral diameter is equal to or greater than half the diameter on the main line sewer, except for a 150mm diameter pipe connecting to a 250mm diameter mainline or a 200mm diameter pipe connecting to a 375mm diameter mainline (see matrix below). If necessary, risers shall be provided at the main sewer and shown on the profile drawings as per STD DWG. 2-
20 Page: to Connection numbers are to be established prior to construction of the lateral. Pipe materials shall be in accordance with the current Manufacturers Approved Products List, Sanitary Sewer and Appurtenances. Sampling manholes are required for industrial sites. Refer to STD DWG for industrial buildings and servicing for multiple building industrial sites (no frontage). Maintenance Hole Requirements Matrix MH required = Y MH not required = N Lateral 150 mm ø 200 mm ø 250 mm ø Mainline Sewer 250 mm ø N Y Y 300 mm ø N Y Y 375 mm ø N N Y 450 mm ø N N Y 8.4. Connection Protocol See paragraph 3.1. for Pipe Classification definitions Primary Collection System, larger than or equal to 750mm diameter: Connections with other Major Trunk Sewers and Local Sub-Trunk Sewers permitted No service connections are permitted Local Sub-Trunk Sewer Collection System, 375mm 675mm diameter: Connections with other Sub-Trunk Sewers and Local Sewers permitted Non-residential and residential connections may be permitted on an individual basis. Local Collection System, 250mm 300mm diameter: All types of service connections permitted.
21 Page: NON-PERMITTED USES New construction Connections from foundation, weeping tile drainage, roof drainage or any other storm source are not permitted to discharge into the sanitary sewer system.
22
23 Population Peak Flow Peak Flow Peak Flow (m 3 Population /sec) (m 3 Population /sec) (m 3 /sec) Notes: 1. Domestic sewage flows are based upon a unit sewage flow of Lpcd. 2. The flows in the above table include the Harmon Peaking Factor. 3. Domestic sewage flow for less than 1000 persons shall be 0.013m 3 /sec. 4. Domestic sewage flow for greater than 100,000 persons shall be 7.0 x 10-6 m 3 /sec per capita. 5. Lpcd = Litres per capita per day 1 Litre = metre 3 Date: June 2005 Rev: 1 Approved: SEWAGE FLOWS (EXCLUDING INFILTRATION) STD. DWG
24 Date: June 2005 Approved: Rev: 1 CIRCULAR DRAIN NOMOGRAPH Flowing Full STD. DWG
25 Date: June 2005 Approved: Rev: 1 DISCHARGE AND VELOCITY (FOR CIRCULAR PIPE n=0.013) STD. DWG
26 DEPTH OF FLOW (%) HYDRAULIC ELEMENTS Percent of Value for Full Pipe (Approx.) EXAMPLE : GIVEN: FIND: Discharge = m 3 /sec through a pipe which has capacity flowing full of m 3 /sec at velocity of 2.13m/sec V for Q = m 3 /sec Since percentage of full discharge = 0.341/0.426 = 80%, enter chart at 80% of value for full section of hydraulic elements Find V = 112.5% x 2.13m/sec = 2.4m/sec Date: June 2005 Rev: 1 Approved: VALUES OF HYDRAULIC ELEMENTS OF CIRCULAR SECTION FOR VARIOUS DEPTHS OF FLOW STD. DWG
27 DEPTH OF COVER PIPE SIZE - Inside Diameter (mm) (m) NOTES 1.8 S.S. CLASS II (50D) E.S. CLASS III (65D) CLASS IV (100D) 4.8 SEE NOTE No DESIGN CRITERIA - The table is based on a backfill weight of 2242 kg/m and a KU value of Safety factors: ASTM C14( ) 1.50, ASTM C76( ) Bedding factors: Class B = 1.9 Class A = 2.8 Class AA = MAXIMUM TRENCH WIDTH AT TOP OF PIPE: = O.D mm = O.D mm = O.D mm 3. TYPE B BEDDING UNLESS OTHERWISE NOTED. 4. PIPE MANUFACTURED TO CURRENT C.S.A STANDARD SPECIFICATION. 5. SPECIAL DESIGNS ARE REQUIRED BEYOND THE DEPTH LIMIT OF THE CHART AND WHEN TRENCH WIDTH AT TOP OF PIPE EXCEEDS THAT SPECIFIED BY NOTE AT DEPTHS > 3.7m, USE EITHER 250mm E.S. WITH A OR AA BEDDING, OR INVESTIGATE ASBESTOS CEMENT OR VIT. CLAY PIPE WITH B BEDDING 7. CLASS 5 (140D) ADEQUATE TO 12m DEPTH (DEPENDING ON EXISTING SOIL CONDITIONS) CLASS V (140D) Date: June 2005 Rev: 1 Approved: PIPE CLASS REQUIREMENTS For Concrete Pipe STD. DWG
28 Date: June 2005 Rev: 1 Approved: COMPUTATION DIAGRAM FOR SOIL LOADS ON TRENCH INSTALLATIONS (PIPE COMPLETELY BURIED IN TRENCHES) STD. DWG
29 Date: June 2005 Rev: 1 Approved: VALUES OF B d / B C AT WHICH PIPE IN TRENCH AND PROJECTING PIPE LOAD FORMULAES GIVE EQUAL LOADS STD. DWG
PUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL LINEAR INFRASTRUCTURE
REGION OF PEEL PUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL LINEAR INFRASTRUCTURE Storm Sewer Design Criteria REVISED July 2009 PUBLIC WORKS STORM SEWER DESIGN CRITERIA TABLE OF CONTENTS 1.0
SECTION 5: SANITARY SEWER SYSTEM DESIGN
SECTION 5: SANITARY SEWER SYSTEM DESIGN 5.01 GENERAL Sanitary sewer improvements shall be designed to serve the ultimate level of City development as defined in the General Plan and the Wastewater Facilities
SECTION 6A STORM DRAIN DESIGN Mar. 2002 S E C T I O N 6A STORM DRAIN - DESIGN
S E C T I O N 6A STORM DRAIN - DESIGN 6A.l Scope 6A.2 Storm Water Quantity 6A.3 Storm Drain Hydraulics 6A.4 Depths 6A.5 Locations 6A.6 Curved Storm Drains 6A.7 Manholes 6A.8 Catch basins 6A.9 Storm Drain
REGION OF PEEL PUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL
REGION OF PEEL PUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL LINEAR INFRASTRUCTURE Functional Servicing and Storm Water Management Report PUBLIC WORKS TABLE OF CONTENTS 1. INTRODUCTION...1 2.
Design Specifications & Requirements Manual
3 SANITARY SEWER COLLECTIONS 3.1 DEFINITION... 1 3.1.1 Public Sewage Systems... 1 3.1.2 Private Sewage Systems... 1 3.2 NON-PERMITTED FLOWS... 1 3.3 LOCATION AND ALIGNMENT... 1 3.3.1 Sanitary Sewers on
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS While its use is not required, this checklist has been prepared to provide the field inspector a summary
Engineering Specifications February, 2004 Schedule H to Bylaw 7452, Subdivision Bylaw Page 18
Schedule H to Bylaw 7452, Subdivision Bylaw Page 18 3.4 Sanitary Sewers 3.4.1 Materials 3.4.1.1 The class and type of pipe and fittings, together with required class of bedding and trench widths, shall
SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)
SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701) 55-1 GENERAL The Contractor shall perform all work required by the plans for construction of pipe for storm drains, precast polymer trench drains
SECTION 3 SANITARY SEWER DESIGN
SECTION 3 SANITARY SEWER DESIGN 3.1 GENERAL DESIGN CRITERIA 3.1.1 Requirement for Sanitary Sewer 3.1.2 Design Approval 3.1.3 IEPA Permit Required 3.1.4 Differentiation Between Public and Private Sanitary
SECTION 7- STORM SEWER
SECTION 7- STORM SEWER 7.1. STORM SEWERS.... 7-1 7.2. SUMP DRAINS... 7-3 7.3. CATCH BASINS... 7-3 7.4. MANHOLES... 7-4 7.5. STORM SEWER CALCULATIONS... 7-4 7.6. CULVERTS AND BRIDGES... 7-5 7.7. OPEN CHANNELS...
STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY
STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY Approved and adopted as Official Document Number 800576 this 10th day of December, 1980 Donald R. Boyd, P.E., Director Water
OAR52 A-1 (September, 1981)
APPENDIX A SEWER PIPELINES (1) MINIMUM REQUIREMENTS FOR SEWER - PIPELINES (a) Capacity: Sewers shall be of such diameter as to pass without overflow, bypass, or back flow onto damageable property of a
SANITARY SEWER SPECIFICATIONS
SANITARY SEWER SPECIFICATIONS OCTOBER 2003 HARVEST-MONROVIA WATER, SEWER, AND FIRE PROTECTION AUTHORITY SECTION 1.00 1.10 Purpose The purpose of this document is to assemble the sewer specifications, policies,
CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT
Page 1 CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT CIVIC CENTRE 2141 MAJOR MACKENZIE DRIVE MAPLE ONTARIO L6A 1T1 905-832-2281 Page 2 SECTION 1 - GENERAL OBJECTIVES To provide
Chapter 9 Sanitary Sewers
Chapter 9 Sanitary Sewers S:/Engineering/Design Standards/Chapter 9 12/29/2014 Section 9.1 Topic General Requirements Chapter 9 Sanitary Sewers Page 9-1 9.2 Plan Submittals 9-1 9.3 Determination of Flow
SECTION 08000 STORM DRAINAGE TABLE OF CONTENTS
SECTION 08000 STORM DRAINAGE 08010 DESIGN A. Location B. Sizing TABLE OF CONTENTS 08020 MATERIALS A. Pipe Materials B. Structure Materials C. Installation D. Inlets and Outlets 08030 INSPECTIONS AND TESTING
SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE
6.01 SCOPE The work covered by this section of the specifications consists of the furnishing of all plant, labor, materials, equipment and supervision and performing all operations involved in the construction
DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL
DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL 1.01 DESCRIPTION A. Furnish and install all storm drains, including manholes, inlets, service lines and other appurtenant
THE CORPORATION OF THE CITY OF GUELPH. THEREFORE the council of the Corporation of the City of Guelph enacts as follows:
THE CORPORATION OF THE CITY OF GUELPH By-law (1993)-14515 A by-law respecting storm water disposal from private property in the City of Guelph, to amend By-law (1987)-12602 and to adopt Municipal Code
SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION
SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION 1. SCOPE Pipe subsoil drains shall be constructed in accordance with this specification and in conformity with the lines, grades and cross-sections shown
PART 6 - STANDARD DESIGN AND CALCULATION FORMS 6.1 SANITARY SEWER DATA SHEET
PART 6 - STANDARD DESIGN AND CALCULATION FORMS 6.1 SANITARY SEWER DATA SHEET Name of Municipality or Sewer District Name of Project Original Township and Lot Number Name of Engineer of Firm Preparing Plans
PART 5 : WASTEWATER DRAINAGE
Authorised by : City Waters Unit Manager Page 1 of 15 PART 5 : WASTEWATER DRAINAGE 5.1 INTRODUCTION This Manual sets out the basic design principles for drainage of wastewater. While some construction
CHAPTER 17: STORM SEWER STANDARDS. 17.00 Introduction. 17.01 Administration. 17.02 Standards 17.1
CHAPTER 17: STORM SEWER STANDARDS 17.00 Introduction 17.01 Administration 17.02 Standards 17.1 17.00 INTRODUCTION The purpose of this chapter is to provide guidance for the design and construction of storm
City of Edmonton Page 1 of 5 Foundation Drain Discharge Collection System Guideline November, 2005
City of Edmonton Page 1 of 5 This guideline will apply to all new developments involving singledetached, semi-detached or duplex houses in the City of Edmonton effective January 1, 2006. Preamble: This
SECTION 02612 NONREINFORCED CONCRETE SEWER PIPE
SECTION 02612 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Furnishing and installing nonreinforced concrete sewer pipe. Provide concrete sewer pipe less than 12 inches in diameter, and in other sizes
SERVICE LINE EXTENSION AND SERVICE LINE CONNECTION CONDENSED SANITARY SEWER SYSTEM INSTALLATION SPECIFICATIONS
1001 SOUTH LEECHBURG HILL LEECHBURG, PA 15656 Phone: 724-845-9355 Fax: 724-845-1186 SERVICE LINE EXTENSION AND SERVICE LINE CONNECTION CONDENSED SANITARY SEWER SYSTEM INSTALLATION SPECIFICATIONS 1. General
Beacon Hill Sewer District Standard Specifications
Beacon Hill Sewer District Standard Specifications Residential Gravity Side Sewer Including Design Criteria and Standard Construction Drawings Residential Gravity Side Sewer Design Criteria 1. Provisions
Pipes and Fittings for Gravity Sewer Mains. SewerMAX
SewerMAX High resistance to tree root intrusion and groundwater infiltration lightweight for ease of installation low embodied energy for environmental benefits long service life Excellent chemical resistance
Civil. 2. City of Seattle Supplement to the Specification for Road, Bridge and Municipal Construction, most current addition.
Design Guide Basis of Design This section applies to the design and installation of earthwork and backfill. Design Criteria No stockpiling of excavation materials is allowed unless the Geotechnical Engineer
CHAPTER 2 HYDRAULICS OF SEWERS
CHAPTER 2 HYDRAULICS OF SEWERS SANITARY SEWERS The hydraulic design procedure for sewers requires: 1. Determination of Sewer System Type 2. Determination of Design Flow 3. Selection of Pipe Size 4. Determination
The Manitoba Water Services Board SECTION 022180 Standard Construction Specifications PIPE EXCAVATION, BEDDING AND BACKFILL Page 1 of 11
Page 1 of 11 Part 1 General 1.1 DESCRIPTION OF WORK.1 The work described herein shall consist of the excavation of trenches (or excavation of tunnels); the supply and placing of bedding and backfill materials;
3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.
The following shall serve as the minimum requirements for contractors performing work in relation to the Authority s potable water and sanitary sewer system(s), appurtenances and service connections. General:
Nebraska Department of Roads Drainage and Erosion Control Manual December 2011 Appendix C: Pipe Material Policy Page C-1 PIPE MATERIAL POLICY
Appendix C: Pipe Material Policy Page C-1 PIPE MATERIAL POLICY Policy: This policy will replace all previous policies regarding the selection of pipe material for cross drains, drive pipe, drop pipe, storm
SECTION 5 - STORM DRAINS
Drainage Criteria Manual SECTION 5 - STORM DRAINS 5.1.0 GENERAL This The purpose of this section discusses briefly is to consider the hydraulic aspects of storm drains and their appurtenances in a storm
LS 2540 SEWER LATERALS AND INSPECTION TEES
LS 2540 SEWER LATERALS AND INSPECTION TEES A. Summary B. Submittals C. Site Information D. Sewer Pipe and Fittings E. Lateral Locations F. Lateral Installation G. Inspection Tee Installation H. Removal
SECTION 33 41 13 PUBLIC STORM UTILITY DRAINAGE PIPING
SECTION 33 41 13 PUBLIC STORM PART 1 - GENERAL 1.01 SECTION INCLUDES A. Storm drainage piping, fittings, and accessories at proposed station areas and locations other than under and immediately adjacent
The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm:
Page 1 of 6 Section 1. PURPOSE This policy is an Engineering checklist of the Local Review Program for sanitary sewer improvement projects by the Bedford Regional Water Authority ( Authority ). Section
CHAPTER 5. Storm Sewer
CHAPTER 5 Storm Sewer A. Introduction All proposed developments shall have a properly designed and constructed storm water conveyance system. This chapter deals only with the conveyance system. Storm water
3A-1---------------------------------General Information A. Concepts... 1 B. Conditions... 1
Statewide Urban Design and Specifications Table of Contents Design Manual Chapter 3 Sanitary Sewers Table of Contents TOC Chapter 3 Sanitary Sewers 3A General Information 3A-1---------------------------------General
L4. Pipes Materials and Loads
The Islamic University of Gaza- Civil Engineering Department SanitaryEngineering- ECIV 4325 L4. Pipes Materials an Loas Base on Dr. Fahi Rabah lecture notes Pipes Materials an loas Materials use for pipes:
Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL
155 E. Front Street (rear) Lititz, PA 17543 Phone (717) 625-1930 Fax (717) 625-1931 Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL CONSTRUCTION SPECIFICATIONS AND DETAILS
Amendment to OPSS 415 (Nov 2008) Construction Specification for Pipeline and Utility Installation by Tunnelling
Engineering and Construction Services Division Standard Specifications for Sewers and Watermains TS 415 April 2013 Amendment to OPSS 415 (Nov 2008) Construction Specification for Pipeline and Utility Installation
UPDATED FUNCTIONAL SERVICING and STORMWATER MANAGEMENT REPORT
TRAFALGAR ENGINEERING LTD. #1-481 Morden Road Oakville Ontario L6K 3W6 UPDATED FUNCTIONAL SERVICING and STORMWATER MANAGEMENT REPORT Fernbrook Homes (Bronte 15) Limited 3059/3047 Lakeshore Road West TOWN
SECTION 33 31 00.11 GRAVITY SANITARY SEWERS
SECTION 33 31 00.11 GRAVITY SANITARY SEWERS PART 1: GENERAL 1.01 SCOPE A. Gravity sanitary sewers and appurtenances. 1.02 SUBMITTALS A. Conform to requirements of Section 01 33 00 Submittals. B. Submit
City of Regina Standard Construction Specification SECTION 1320 SEWERMAIN TESTING
1.0 GENERAL 1.1 Scope 2.0 PRODUCTS 1.1.1 The work shall consist of testing wastewater and/or storm mains to ensure construction conforms to the proper line, grade, cross section and performance. 2.1 The
SECTION G SEWERS (STORM, SANITARY AND FDC)
G-1 GENERAL SECTION G SEWERS (STORM, SANITARY AND FDC) The Consulting Engineer is to monitor all specified pipe and granular materials, pipe slopes and run lengths and ensure the outlined criteria below
Exhibit A. Rules and Regulations for House Connections and Sewer Extensions
The purpose of this application example is to provide assistance to small and medium sized rural communities in the drafting of documents necessary for the efficient operation of water, wastewater, and
Section 402. STORM SEWERS
402.02 Section 402. STORM SEWERS 402.01. Description. This work consists of constructing storm sewers of the size and class required, including excavation, bedding, and backfill. 402.02. Materials. Provide
EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines
EXHIBIT "A Technical Specifications for Water and Sewer Service Lines Water and Sewer Line Bedding and Backfill: Drawings show cross-section of trench, pipe laid on top of 6" min. bedding material, bedding
SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)
Page 1 of 7 STONE STRONG SYSTEMS SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised ) PART 1: GENERAL 1.01 Description A. Work includes furnishing and installing precast modular blocks
CHAPTER 3 STORM DRAINAGE SYSTEMS
CHAPTER 3 STORM DRAINAGE SYSTEMS 3.7 Storm Drains 3.7.1 Introduction After the tentative locations of inlets, drain pipes, and outfalls with tail-waters have been determined and the inlets sized, the next
Prepare a drainage system layout and specification notes for a low- rise building.
STUDENT MATERIALS Prepare a drainage system layout and specification notes for a low- Outcome 1 - rise building. In this outcome you will study the technology of below and above ground drainage systems.
CITY UTILITIES DESIGN STANDARDS MANUAL
CITY UTILITIES DESIGN STANDARDS MANUAL Book 2 (SW) SW9 June 2015 SW9.01 Purpose This Chapter provides information for the design of open channels for the conveyance of stormwater in the City of Fort Wayne.
Native InDesign 2890 SaniTite Brochure 1/8" 100 300 CMYK April 17, 07
Sanitary Sewer Pipe Tough pipe for a tough environment SaniTite Sanitary Sewer Pipe delivers the features that engineers, contractors and municipalities demand durability, performance, handling, toughness
Minimum Design Criteria for the permitting of Gravity Sewers
Minimum Design Criteria for the permitting of Gravity Sewers Adopted by the Division of Water Quality on February 12, 1996 Updated to 15A NCAC 2T Regulations on March 2008 1,400 copies of this document
Introduction. Contents. General. Materials and workmanship. Diagrams. Other regulations. References
Introduction General This Technical Booklet has been prepared by the Department of the Environment for Northern Ireland and provides for certain methods and standards of building which, if followed, will
CW 2130 - GRAVITY SEWERS TABLE OF CONTENTS
August 2010 CW 2130 - GRAVITY SEWERS TABLE OF CONTENTS 1. DESCRIPTION... 1 1.1 General... 1 1.2 Definitions... 1 1.3 Referenced Standard Construction Specifications... 1 1.4 Referenced Standard Details...
APPLICATION PROCEDURES FOR PLACEMENT OF UNDERGROUND WATER AND SEWER PIPELINES IN THE VICINITY OF TRANSPORTATION FACILITIES UNDER THE
APPLICATION PROCEDURES FOR PLACEMENT OF UNDERGROUND WATER AND SEWER PIPELINES IN THE VICINITY OF TRANSPORTATION FACILITIES UNDER THE JURISDICTION OF ALBERTA TRANSPORTATION 1.0 Application Procedures 2.0
Section 2100-Trenching and Tunneling
SECTION 5200 - STORM SEWER PART 1 - GENERAL 1.01 SCOPE: This Section covers installation of storm sewer mains and culverts. Topics include permits and fees, trench widths, pipe laying, bedding, initial
SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT
SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT The following are minimum requirements for installation of conventional trench sewage disposal systems in St. Mary s County,
SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.
SECTION LS 2530 SANITARY SEWERS PART 1 GENERAL 1.1 SUBMITTALS A. General: Submit the following in accordance with The General Conditions. 1. Product data for drainage piping specialties. 2. Shop drawings
The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.
Section 33 0200- Page 1 of 4 PART 1 - GENERAL 1.1 DESCRIPTION OF WORK The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.
DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES 33 00 00 SITE UTILITIES
SECTION INCLUDES Domestic Water Fire Water Service Water Well Sanitary Sewer Storm Drains Foundation Drainage RELATED SECTIONS 03 30 00 Concrete 21 00 00 Fire Suppression - Sprinklers 22 00 00 Plumbing
APPLICATION FOR DEMOLITION & RIGHT-OF OF-WAY PERMIT
APPLICATION FOR DEMOLITION & RIGHT-OF OF-WAY PERMIT City of Swartz Creek 8083 Civic Drive Swartz Creek, MI 48473 810-635-4464 Fee Received: $ Date: / / Receipt No: Demolition Permit (including Right of
CHAPTER 11 STORM DRAINAGE
CHAPTER 11 STORM DRAINAGE SECTION 11 GENERAL 11.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. 11.2 Where required. All roofs,
CITY OF ANN ARBOR PUBLIC SERVICES PLAN REVIEW CHECKLIST
CITY OF ANN ARBOR PUBLIC SERVICES PLAN REVIEW CHECKLIST NOTE: The following list shall only be used as a guide and shall not be used in lieu of the specifications found in the CITY OF ANN ARBOR PUBLIC
SECTION 02630 STORM DRAINAGE SYSTEM
SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE
ARTICLE II (2) ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH 020001 Purpose and Application.
ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH 020001 Purpose and Application. Article II provides rules governing the allowable connection to the City POTW and the construction and inspection of
Specifications for Residential Property Owners Connection to New Public Sewer
Specifications for Residential Property Owners Connection to New Public Sewer Spalding Tract property owners are required to connect to the community sewer system when construction is complete and the
89 Avenue Road GP Ltd. Functional Servicing and Stormwater Management Report for 89 Avenue Road Re-Development City of Toronto
89 Avenue Road GP Ltd. Functional Servicing and Stormwater Management Report for 89 Avenue Road Re-Development City of Toronto Prepared By: R.J. Burnside & Associates Limited 6990 Creditview Road, Unit
CITY OF ST. CA THARINE S. cn- Olc.4 BY-LAW NO. WHEREAS the Council of the Corporation of the City of St. Catharines, is
~: ~,,' " CITY OF ST. CA THARINE S BY-LAW NO. cn- Olc.4 A By-law to regulate sanitary and storm drainage. WHEREAS the Council of the Corporation of the City of St. Catharines, is authorized by the provisions
Module 7: Hydraulic Design of Sewers and Storm Water Drains. Lecture 7 : Hydraulic Design of Sewers and Storm Water Drains
1 P age Module 7: Hydraulic Design of Sewers and Storm Water Drains Lecture 7 : Hydraulic Design of Sewers and Storm Water Drains 2 P age 7.1 General Consideration Generally, sewers are laid at steeper
Module 6 : Quantity Estimation of Storm Water. Lecture 6 : Quantity Estimation of Storm Water
1 P age Module 6 : Quantity Estimation of Storm Water Lecture 6 : Quantity Estimation of Storm Water 2 P age 6.1 Factors Affecting the Quantity of Stormwater The surface run-off resulting after precipitation
Index. protection. excavated drop inlet protection (Temporary) 6.50.1 6.51.1. Block and gravel inlet Protection (Temporary) 6.52.1
6 Index inlet protection excavated drop inlet protection (Temporary) 6.50.1 HARDWARE CLOTH AND GRAVEL INLET PROTECTION Block and gravel inlet Protection (Temporary) sod drop inlet protection ROCK DOUGHNUT
32-02.05 Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.
SECTION 32: SANITARY SEWER INSTALLATION 32-01 SCOPE. The Work shall consist of furnishing and installing sewer mains, manholes, laterals, cleanout fittings and appurtenances; and testing, flushing and
CCU Engineering Specifications. Section 003300 PRECAST CONCRETE PRODUCTS
CCU Engineering Specifications Section 003300 Effective Date: Nov. 1st, 2011 Page 1 of 5 PRECAST CONCRETE PRODUCTS PART 1 - GENERAL The following specification is intended for use for the design, selection
Wastewater Capital Projects Management Standard Construction Specification
CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 Precast Concrete Pipe 10.1.1 General This section covers material requirements,
Section 02702 SEWER PIPE INSTALLATION AND TESTING
PART 1 - GENERAL Section 02702 SEWER PIPE INSTALLATION AND TESTING 1-1. SCOPE. This section covers the installation and testing of all sewer pipe furnished under the following specification sections: Concrete
Pipeline design. concrete for life
Pipeline design concrete for life Pipeline Design Pipeline design - hydraulic Graph showing relative velocity and discharge in a circular pipe for any depth of flow 1.0 0.9 0.8 0.7 Proportional depth of
See Appendix A for additional information, or contact ASTM directly.
DEFINITIONS Wherever used in these specification guidelines, the following words and terms have the meanings indicated. AREAWAY: A paved surface, serving as an entry area to a basement or subsurface portion
550 PIPE CULVERTS, SEWERS AND DRAINS
551.01 550 PIPE CULVERTS, SEWERS AND DRAINS 551 GENERAL 551.01 Description 551.02 Materials 551.03 Excavation 551.04 Protection of Excavation 551.05(a) Bedding for Rigid Pipe 551.05(b) Bedding for Non-Rigid
Royal Seal Gasketed Sewer Pipe
Royal Seal Gasketed Sewer Pipe Royal Seal Gasketed Sewer Pipe Royal Seal gasketed sewer pipe with our specially designed Double Seal Locked-In (DSLI ) gasket is an extremely durable pipe with a leak proof
The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe
The Most Advanced Name in Drainage Systems Sanitary Sewer Pipe SaniTite Sanitary Sewer Pipe delivers the features that engineers, contractors and municipalities demand durability, performance, handling,
The Manitoba Water Services Board SECTION 027030 Standard Construction Specifications September 2013 Page 1 of 21
September 2013 Page 1 of 21 Part 1 General 1.1 DESCRIPTION OF WORK.1 The work described herein shall consist of the construction of sewers including: the supply and installation of pipe, saddles, tees,
Greater Dublin Strategic Drainage Study Regional Drainage Policies - Volume 2 New Development
7 SPECIFICATIONS There is currently no Irish specification for construction of drainage works, or water supply works. There are several publications that give guidance on drainage works, such as the Building
Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS
Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS TABLE OF CONTENTS I. RULES AND REGULATIONS A. TABLE OF CONTENTS... 2 B. TERMS AND DEFINITIONS... 3 C. DEVELOPER S/CONTRACTOR S RESPONSIBILITIES...
STANDARD SPECIFICATIONS SECTION 02701 INSTALLATION OF GRAVITY SEWER PIPELINES. 1. Trenching, Backfilling and Compacting: 02223
STANDARD SPECIFICATIONS SECTION 02701 INSTALLATION OF GRAVITY SEWER PIPELINES PART 1 - GENERAL A. Description This section describes the installation of gravity sewer pipelines fabricated of vitrified
M6a: Open Channel Flow (Manning s Equation, Partially Flowing Pipes, and Specific Energy)
M6a: Open Channel Flow (, Partially Flowing Pipes, and Specific Energy) Steady Non-Uniform Flow in an Open Channel Robert Pitt University of Alabama and Shirley Clark Penn State - Harrisburg Continuity
CHAPTER 11 STORM DRAINAGE
CHAPTER STORM DRAINAGE SECTION PC 0 GENERAL 0. Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. Storm water discharge shall be
Guide to working on Public Sewers
Guide to working on Public Sewers affected by Building Works Introduction Severn Trent Water Ltd requires the work to be done in order to protect the public sewer and minimise the risk of us having to
DIVISION 4300 STORM DRAINAGE
DIVISION 4300 STORM DRAINAGE SECTION 4305 STORM SEWER PART 1 - GENERAL 1.01 SCOPE This section covers the construction of storm sewers for the collection and transport of stormwater runoff. 1.02 REFERENCES
DIVISION OF WATER QUALITY CONSTRUCTION GRANTS & LOANS SECTION FAST TRACK AUDIT CHECKLIST
DIVISION OF WATER QUALITY CONSTRUCTION GRANTS & LOANS SECTION FAST TRACK AUDIT CHECKLIST CERTIFICATION 1. Did the engineer submit a certificate of completion utilizing the appropriate page of the issued
SECTION 33 31 00.13 ABANDONMENT OF SEWER MAINS
SECTION 33 31 00.13 ABANDONMENT OF SEWER MAINS PART 1: GENERAL 1.01 SECTION INCLUDES A. Abandonment in place, by cutting and capping, of existing sewers, junction structures, manholes, service lines, and
ENGINEERING STANDARDS MANUAL SECTION 5 WASTEWATER DRAINAGE
CODE OF PRACTICE FOR CITY INFRASTRUCTURE & LAND DEVELOPMENT ENGINEERING STANDARDS MANUAL SECTION 5 WASTEWATER DRAINAGE Issue 4.6 Sept 2008 Section 5 Page 1 SECTION 5.0 WASTEWATER DRAINAGE Note: The adoption
CHAPTER 6 SEWER SYSTEM DESIGN STANDARDS
CHAPTER 6 SEWER SYSTEM DESIGN STANDARDS TABLE OF CONTENTS CHAPTER 6 SEWER SYSTEM DESIGN STANDARDS 6.00 Objective Page 1 6.01 Additional Referenced Standards Page 2 6.02 Special Design Problems Page 2 6.03
STORM DRAINS CHAPTER 7
CHAPTER 7 Chapter 7 - Storm Drains A storm drain is a drainage system that conveys water or stormwater, consisting of two or more pipes in a series connected by one or more structures. Storm drains collect
