1 AF2000 MT Mid Temperature Asymmetric Flow FFF The Most Powerful Temperature Controlled Asymmetric Flow FFF Separation Technology

2 POSTNOVA ANALYTICS Postnova Analytics is completely focused on Field-Flow Fractionation (FFF) and Light Scattering (LS) technology, offering a unique product portfolio of integrated FFF and LS systems. Postnova combines the heritage of Prof. Giddings, the inventor of FFF, with a unique 40 year long history in FFF science. The company has an unlimited commitment to Field-Flow Fractionation and Light Scattering excellence and always striving to represent the center of excellence in FFF and LS business. Our customers can expect the most advanced and reliable analytical solutions for their demanding applications from nanotechnology, polymers and bioscience. s o p t S v o n a 20 a n a n YEARS a l y INCE t i c s FFF HISTORY In 1966 Field-Flow Fractionation was invented by Prof. Calvin Giddings ( ) [01], an outstanding scientist and two-times Nobel-Price nominee (1984/1994), from University Utah at Salt Lake City, USA. He also was the founder of the FFFresearch Center at University of Utah, where he and his team developed the complete theory of FFF and the different sub-techniques, such as Thermal FFF [02] in 1969, Sedimentation FFF [03] in 1974, Flow FFF [04] in 1976 and SPLITT in 1985 [05]. In 1987 Giddings/Wahlund published the first Asymmetric Flow FFF [06], which later became the most popular FFF technology used today Prof. Michel Martin from Univ. Paris published the world s first online coupling of FFF with Light Scattering [7,8]. In 1986, Prof. Giddings and his co-workers founded the legendary FFFractionation Inc. in Salt Lake City, which was the first FFF company ever. FFFractionation developed and introduced the first commercial FFF instruments, which were the Model T100 Thermal FFF, S101 Sedimentation FFF, F1000 Flow FFF and SF1000 Split Thin Flow Cell Fractionation (SPLITT) [9,10,11,12]. In 1995 Dr. T. Klein developed a new type of Asymmetric Flow FFF after studies at Ciba- Geigy (now Novartis), in Basel, Switzerland and the Technical University of Munich, Germany. After that he founded Postnova Analytics in Munich in 1997, which introduced the first Asymmetrical Flow FFF into the market. In 2001 Postnova Analytics and FFFractionation merged together, forming the leading company in the area of FFF LS. Just recently, Postnova Analytics presented the world s first High Temperature [13] and Mid Temperature Asymmetric Flow FFF technology. Literature: [1] J.C. Giddings, New separation concept based on a coupling of concentration and flow non-uniformities, Separation Sci., (1966). [2] G.H. Thompson, M.N. Myers, and J.C. Giddings, "Thermal Field-Flow Fractionation of Polystyrene Samples", Anal. Chem., (1969). [3] J.C. Giddings, F.J.F. Yang, M.N. Myers, "Sedimentation Field-Flow Fractionation", Anal. Chem., (1974). [4] J.C. Giddings, F.J. Yang, M.N. Myers, "Flow Field-Flow Fractionation: A Versatile New Separation Method", Science, (1976). [5] J.C. Giddings, "A System Based on Split-Flow Lateral-Transport Thin (SPLITT) Separation Cells for Rapid and Continuous Particle Fractionation", Sep. Sci. Technol., (1985). [6] Wahlund, K.G.; Giddings, J.C.; Properties of an Asym. Flow FFF channel having one permeable wall, Anal. Chem., (1987). [7] Martin, M.; Polymer analysis by fractionation with on-line light scattering detectors, Sep. Sci. Technol.; Sep. Sci. Technol.; (1982). [8] Martin, M.; Hes, J.; On-line coupling of thermal field-flow fractionation with laser light scattering, Chromatographia; (1984). [9-12] FFFractionation, Inc., Salt Lake City, Utah, USA Model F1000, Model S101, Model T100, Model SF1000, Product Brochures, (1986). [13] H. DeJonge, E. Mes, T. Klein, R. Welz, High Molecular Weight Polyolefin Analysis by High Temperature Asymmetrical Flow Field-Flow Fractionation, Oral Presentation/Poster 1 st ICPC Conference, Houston, USA, Oct. 15 th -18 th (2006).

3 FFF PRINCIPLE Field-Flow Fractionation is a family of unique separation techniques, comprising of various different subtechniques, just like chromatography. All FFF versions utilize the same basic separation principle, but employ different separation fields. Depending on the used separation field, the technique is called Flow FFF, Sedimentation FFF, Thermal FFF, etc.. FFF is providing fast, gentle and high resolution separations of any particulate matter from 1 nm up to 100 µm in any liquid media. The sample is separated inside an open flow channel without the presence of any packing or stationary phase inside. Inside the channel a laminar flow with a parabolic stream profile is formed. The different used force fields, such as liquid flow, centrifugal force, temperature gradient or gravity, are applied perpendicular to the main flow which transports the sample through the channel. Under the influence of these force fields and the counteracting diffusion of the particles, different equilibrium layer heights are formed by the different particle size fractions. Smaller particles, with stronger diffusion are located higher in the channel in fast stream lines and elute first. Bigger particles with a lower diffusion coefficient are located in slow stream lines and elute later. ASYMMETRIC FLOW FFF Flow FFF has been the most important FFF technique since two decades now, whereas Asymmetric Flow FFF is subversion of Flow FFF. Postnova Analytics has been setting the standard in this area since the beginning. The company developed and introduced the first Flow FFF instrument (Model F1000) in 1986, launched the first commercial automated Asymmetric Flow FFF (Model HRFFF ) in 1997, first integrated Asym. Flow FFF in 2004 and finally invented and presented the first temperature controlled Mid Temperature Asymmetric Flow FFF in Today, Postnova s offers its customers the most advanced FFF technology, protected by and based on several patents. In Asymmetric Flow FFF the separation force is generated by a flow field (cross flow) inside the channel. The cross flow is divided from the main flow pumped through the channel and is directed through a semi-permeable membrane which is located at the bottom wall. The membrane pores size prevents the sample to pass through, but allows the solvent to exit the channel easily. The sample fractions are eluted out of the channel in direction to the detectors by the remaining channel flow.

4 AF2000 MT MID TEMPERATURE ASYMMETRIC FLOW FFF Postnova has invented a new type of temperature controlled Asymmetric Flow FFF. Actually it is the first commercial Flow FFF instrument available with temperature control for advanced FFF studies. The system outperforms GPC, because of its huge separation range, high separation power and ability to separate proteins, polymers and nanoparticles at the same time. The AF2000 MT is setting a complete new standard in the characterization of macromolecules and marks a real break-through in FFF science. The system is using Postnova s patented channel cartridge design, which enables the user to access complete new applications and to overcome the limitations of the traditionally used other systems. UNIQUE FEATURES OF AF2000 MT Channel Cartridge The channel cartridges used in the AF2000 series system are based on Postnova s patented technology. Micro and analytical channels are available and can be exchanged easily by just replacing the cartridge. Broad Separation Range Other than as in HTGPC, the separation in MTFFF can also be performed for polymers up to molar masses of 10E9 Da. No size exclusion effect is observed, making MTFFF the ideal tool for the separation of large and ultra-large polymers or even nanoparticles. Gentle Separation Conditions Because of the open channel and the absence of any stationary phase the separation can be performed under the absence of shear forces and stress to the macromolecule. Typical HTGPC problems, such as filtering/adsorption effects, shear induced chain degradation and late elution effects can be avoided. Patented FOCUS Technology The AF2000 MT incorporates Postnova s patented FOCUS technology, to ensure a continuous and stable detector flow at any time. This is an absolute necessity, to be able to connect flow sensitive viscometers and RI detectors. Additionally to this, the technology provides also a higher sample recovery, higher resolution and a higher sensitivity. Another striking advantage of the Focus technology is that the channel outlet can be directly connected to the detector without any valve or T- piece build in between. This ensures short transfer line, low dead volumes and minimized band broadening. Patented Cross Flow System Postnova is using a patented technology for generating the cross flow inside the FFF channel, based on a double syringe pump. This pump is controlled in a special unique way avoiding any pulsation. The pump is completely inert and can easily produce constant and absolute flows ranging from 0,005 to 10 ml/min for different solvents. Using the volumetric based syringe pump technology, a certain volume per time is removed independent from the nature of the solvent and the temperature. NovaFFF Software Platform Postnova offers an integrated single software platform for system control, data acquisition and data evaluation of different FFF and detector systems. The software incorporates an advanced Light Scattering module for molar mass and particle size calculations. Flexibility & Interfaceability The AF2000 MT series was developed to be used as Stand-Alone system or interfaced with existing HTGPC systems from various manufacturers. This gives the advantage that FFF and GPC can be performed using the same set or detectors, using the same temperature chamber for GPC and FFF.

5 NOVAFFF SOFTWARE The NovaFFF software is based on a single platform strategy, incorporating system control, data collection and data evaluation as well as reporting. Set-up & Handling & Security The NovaFFF software is easy to use and incorporates the complete knowledge of over two decades in FFF and Light Scattering technology. It is very flexible, as different hardware components, such as autosampler, pumps and various detectors can be selected by the user with just a few mouse clicks. Various security and monitoring functions have been built into the software. The pump and channel pressure is actively monitored. The system can be shut down manually or automatically when a set maximum pressure value is exceeded. The main actions and controls done by the software are stored in a log history file. Also, all important data such as pressures, flows and additional analog detector signals are collected and stored with the run data. Modern System Control State-of-the-art modern communication protocols are standard in this software solution. The communication of the program with PC and the system components is achieved via TCP/IP Ethernet protocol and no data acquisition boards or external controllers are necessary. As the FFF system has it s own IP address, thus the complete system can be operated via the local network in the user s environment. Seamless FFF-LS Integration The software uniquely combines the system control of FFF and the selected Light Scattering detector in just one application. Start-up of two programs, copy and pasting of methods between the different programs or problems about the stability of the multitasking capabilities of the PC operating system are history when using NovaFFF. Data Evaluation and Calculation After finishing a sample measurement, immediately the data evaluation, molar mass and radius calculations can be performed. Also the corresponding mass and radius distributions, conformation plots and different reporting functions can be accessed, while the system is performing the next run. Unique Features at a Glance One software platform for different FFF techniques Single program for system control, data acquisition and evaluation Direct control and data acquisition of different light scattering detectors Easy to use software with fast start up procedure using run/method templates Highly flexible program, as different hardware can be selected Advanced Light Scattering data evaluation and reporting module incorporated Various built-in manual and automatic security options for safe and smooth operation

6 SPECIFICATIONS Temperature Range: Cooling real 5 C Heating max. 80 C Measurement Range: Polymers: Da / Nanoparticles: 1nm-10µm (Depending on membrane and sample material) Channel Cartridge System: Patented Postnova channel system: - Inner Volume: 0,5-1,5 ml depending on spacer - Inner Channel Thickness: 350 µm (others available) - Outer Dimensions: 335 x 60 x 40 mm Applicable Solvent Systems: All typical organic and aqueous solvents. Connected Detector Systems: The same well-known detection technologies which are used in HTGPC can also be used in HTFFF: - Low/Right/Multi Angle Light Scattering for MW/Rg - Viscometric Detection for MW/Rh - Refractive Index for Concentration - Infrared Detection for Polyolefin Concentration - Other Technologies: Please inquire on availability Flow Rate Ranges / Pressure: Detector Flow 0,01-2,0 ml/min at channel outlet Cross Flow 0 or 0, ml/min Channel Pressure up to 50 bar maximum Required Analysis Time: Typically min; shorter/longer times possible Electrical Power Requirements: 230V, 50Hz: Min-Max / 1,2 kw-3,6kw at 6,3-15,6A 110V, 60Hz: Min-Max / 0,6 kw-1,8kw at 6,3-15,6A 100V (Japan): Please inquire for power requirements. All values are for the basic set-up without detectors only. PC Requirements: Windows OS, min.1024 MB RAM, 2 Ethernet ports Software System: Unique NovaFFF software platform for complete system control (autosampler, pumps, detectors), data acquisition (detector signals, pressure, flows) and evaluation as well as reporting functions (static light scattering calculations, standard calibration). Maintenance Parts: Pump seals, pistons and check valves as usual. The channel cartridge itself is inert and made of special unique materials. It can be regenerated after heavy use and thus be re-used many times. Injection Volume: - Typically µl with autosampler injection / - Typically µl with manual injection Band broadening is not affected by injection volume because of patented focus technology used inside. Injected Sample Mass: Limiting parameter is channel overloading, which is primarily depending on the channel dimensions. Typical injected sample mass for given channel size is µg. The maximum sample mass can go up to 500 µg, depending on sample nature.

7 FFF & LS PRODUCTS Postnova Analytics is focused on products based on Field-Flow Fractionation and Light Scattering for applications in Biotechnology, Pharma, Chemistry and Environmental Science. We offer complete analytical systems, services and supplies from one hand. AF2000 AT/MT/HT Series Flow FFF The most advanced Flow FFF technology for the characterization of proteins, polymers and nanoparticles in aqueous and organic solvents at ambient (AT), middle (MT) and high temperatures (HT). Unbeaten reproducibility and resolution can be achieved easily with these kind of Flow FFF series. S101 Series Sedimentation FFF The benchmark in high resolution FFF separation of nanoparticles, such as emulsions, latexes and colloids in aqueous solvents. Model S101 is ideal for biological particles as well and can be applied in the range from 50nm to 100 µm. TF200 Series Thermal FFF Our brand new TF2000 Series is based on the Thermal FFF principle and is the technology of choice for characterization of polymers and gels in organic solvents. Thermal FFF can separate polymers by molar mass and by chemical composition. PN3000 Series Static-Dynamic Light Scattering (MALS/DLS) The PN3000 MALS series is the ideal LS detector for coupling with FFF, GPC and HPLC. The compact instrument is available as Single/Dual/Multi-Angle Static LS version for ambient and high temperature applications. Dynamic Light Scattering (DLS) as an extra option is available as well. Worldwide Class Support Postnova Analytics is located where its customers are located. Beside our facilities in Germany (HQs) and America (USA), we have established a local support network of highly qualified partner organizations. If you just need a spare part, if you are looking for a special training course, or if you need immediate help for a demanding application, Postnova can assist you like no other in the FFF - LS business. EAC European Application Center AAC American Application Center The European and the American Application Centers (EAC / AAC) which are located in our German and US offices are playing a central role in our support activities. These centers provide the highest quality application support to the scientific community and host the training and educational services, which are offered for all our product lines on a frequent basis, as well. The long history in FFF and the broad FFF product range are building the basis for this unsurpassed, extensive scientific support offered. This is underlined by the significant number of former scientists and PhDs coming from Prof. Giddings group, which have been employed by FFFractionation/Postnova over the years. CONTACT Postnova Analytics GmbH, Max-Planck-Str. 14, Landsberg, GER, T: , F: Postnova Analytics, Inc., 230 South, 500 East, S. 120, Salt Lake City, USA, T: , F: [email protected] - Web:

8 Postnova Product Portfolio Fax: Tel: Field-Flow Fractionation Systems for Protein, Particle and Polymer Separation & Characterization AF2000 AT: Asymmetric Flow Field-Flow Fractionation for Particle, Polymer, Protein Characterization AF2000 MT: Mid Temp Asymmetric Flow Field-Flow Fractionation for Particle, Polymer, Protein Characteriz. AF2000 HT: High Temperature Asymmetric Flow Field-Flow Fractionation for Polyolefin Characterization TF2000: Thermal Field-Flow Fractionation for advanced polymer characterization in organic solvents S101: Sedimentation Field-Flow Fractionation for high resolution particle size separation SF1000: SPLITT- Field-Flow Fractionation for continuously preparative scale particle separation HPLC & Syringe Pumps Laser Light Scattering/UV/RI/FL Detectors Degassers - Autosampler PN1130 Pump Series: Double piston pumps for HPLC, SEC, GPC and Micro Reaction technology PN1600 Pump Series: Double piston syringe pumps for HPLC, SEC, GPC and Micro Reaction technology PN3000 MALS Series: Multi Angle Laser Light Scattering (molecular weight, size determination) PN3000 DLS Series: Dynamic Laser Light Scattering (molecular/particle size determination) PN3000 XPT Series: Optical Particle Detection for Microparticles Size, number and shape determination PN3100 RI Series: Refractive Index detector with high sensitivity and base line stability PN3200 UV Series: 1-4-Channel variable wavelength detector for FFF, SEC and HPLC PN3400 FL Series: Fluorescence detector with proven sensitivity and performance PN5100 Manual Injectors: Manual Rheodyne sample injectors for FFF, SEC and HPLC PN5300 Automatic Injectors: Automatic sample injectors for FFF, SEC and HPLC PN7500 Degasser: On-line Degassers with 2 to 4 Channels for aqueous and organic solvents PN8000 Fraction Collectors Consumables for HPLC, GPC, CE, GC and Liquid Handling Upchurch Scientific: Chromatography consumables, tubings and fittings for fluid transfer applications Hamilton: Polymeric HPLC columns, GC columns, GC liner, micro syringes, pipettes and dispenser Rheodyne OEM: Sample injection valves, switching valves, fittings, degasser and debubbler Millipore: Analytical Sample Preparation and solvent filtration MicroSolv: CE Columns, capillaries, buffers, consumables, solutions for CEC, silica HPLC columns Ismatec: High quality peristaltic, tubing, gear pumps and supplies Spectral Lamps: Deuterium lamps, tungsten lamps, Xenon and hollow cathode lamps for LC and AAS Syringe Filters & Vials: Chromatography syringe filter, vials, GPC columns for various applications Fused Silica Tubings: Broadest range of fused silica capillaries with various dimensions (ID/OD) Nanoparticles: Catalog with more than 300 particle sizes, surfaces and materials Polymer Standards: Catalog with all kind of polymers and the broadest range available on the market GPC Columns: High quality GPC/SEC columns; high throughput, analytical and prep for various applications Analytical Services FFF and Light Scattering Application Development with Field-Flow Fractionation Static / Dynamic Laser Light Scattering Characterization of bio macromolecules, polymers and nanoparticles Trainings, Work Shops and Seminars in the European and American Application Centers - EAC / AAC Please send me information material I want to receive the Postnova Newsletter Please send a quotation Title: First Name: Last Name: Company: Department: Street/P.O. Box: ZIP/City/Country: Telephone: Fax: Web: Postnova Analytics GmbH (Europe,Asia,ROW) Max-Planck-Str Landsberg, Germany Postnova Analytics Inc. (The Americas) 230 South 500 East Suite 120 Salt Lake City/UT, USA [email protected]

Chapter 28: High-Performance Liquid Chromatography (HPLC)

Chapter 28: High-Performance Liquid Chromatography (HPLC) Chapter 28: High-Performance Liquid Chromatography (HPLC) Scope Instrumentation eluants, injectors, columns Modes of HPLC Partition chromatography Adsorption chromatography Ion chromatography Size exclusion

More information

Amino Acid Analyzer L-8900

Amino Acid Analyzer L-8900 Amino Acid Analyzer L-8900 VWR - Hitachi Your Partner in Amino Acid Analysis Hitachi has manufactured more than 1800 Amino Acid Analysers for over 40 years. The new Amino Acid Analyser Model L-8900 is

More information

Smartline HPLC by design

Smartline HPLC by design HPLC SMB Osmometry Smartline Systems Smartline HPLC by design Smartline high performance liquid chromatography instruments are designed to provide reliable separation solutions for routine tasks such as

More information

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent

More information

High-Throughput 3-D Chromatography Through Ion Exchange SPE

High-Throughput 3-D Chromatography Through Ion Exchange SPE High-Throughput 3-D Chromatography Through Ion Exchange SPE Application Note 205 Luke Roenneburg and Alan Hamstra (Gilson, Inc.) Introduction 2-dimensional (2-D) separation is the separation of a sample

More information

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry. IFC A new perspective i l ifi ti Medicinal Chemistry p p CombiChem Compound Isolation Autopurification Drug Discovery y y q p p p p g p Single softw FractPAL software plug-in for Agilent ChemStation The

More information

Tips & Tricks GPC/SEC: Analysis and Calibration For Low Molar Mass Macromolecules

Tips & Tricks GPC/SEC: Analysis and Calibration For Low Molar Mass Macromolecules GPC/SEC: Analysis and Calibration For Low Molar Mass Macromolecules Daniela Held, Silvia Fugmann, and Peter Kilz, PSS Polymer Standards Service GmbH, Mainz, Germany. Macromolecules can range from several

More information

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies Application Note Small Molecule Pharmaceuticals Authors Jignesh Shah, Tiantian Li, and Anil Sharma Agilent Technologies,

More information

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation Application Note Determination of Nitrite and Nitrate in Fruit Juices by UV Detection Category Food Matrix Fruit Juice Method HPLC Keywords Ion pair chromatography, fruit juice, inorganic anions AZURA

More information

Protocol: HPLC (amino acids)

Protocol: HPLC (amino acids) Page 1 of 6 1. Chemicals Composition M MW gram volume (ml) product code 0-pthaldialdehyde C 8H 6O 2 134.13 Sigma P0657 Perchloric acid HClO 4 3.5 100.46 Dilute 70% stock solution 1:1 with demi to obtain

More information

Diffusion and Fluid Flow

Diffusion and Fluid Flow Diffusion and Fluid Flow What determines the diffusion coefficient? What determines fluid flow? 1. Diffusion: Diffusion refers to the transport of substance against a concentration gradient. ΔS>0 Mass

More information

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep Guide to Reverse Phase SpinColumns Chromatography for Sample Prep www.harvardapparatus.com Contents Introduction...2-3 Modes of Separation...4-6 Spin Column Efficiency...7-8 Fast Protein Analysis...9 Specifications...10

More information

Western Blot Analysis with Cell Samples Grown in Channel-µ-Slides

Western Blot Analysis with Cell Samples Grown in Channel-µ-Slides Western Blot Analysis with Cell Samples Grown in Channel-µ-Slides Polyacrylamide gel electrophoresis (PAGE) and subsequent analyses are common tools in biochemistry and molecular biology. This Application

More information

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography INTRODUCTION The analysis of soft drinks for caffeine was able to be performed using UV-Vis. The complex sample

More information

On-line Dissolved Gas Analysis

On-line Dissolved Gas Analysis On-line Dissolved Gas Analysis accord. to IEC 567/ASTM 3612 Online-Monitoring of transformers Automatic on-line analysis of 11 gases The analysis is done in 2 steps with high selectivity and accuracy fully

More information

Lovis 2000 M/ME. Microviscometer. ::: Viscometry at its best

Lovis 2000 M/ME. Microviscometer. ::: Viscometry at its best Lovis 2000 M/ME Microviscometer ::: Viscometry at its best Lovis 2000 M/ME is a rolling ball viscometer which unites an established measuring principle (Höppler, DIN 53015 and ISO 12058) with innovative

More information

ORGANIC SAMPLE PREPARATION

ORGANIC SAMPLE PREPARATION ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,

More information

Mitos P-Pump. product datasheet

Mitos P-Pump. product datasheet product datasheet page Product description 2 Main benefits 3 Why choose the Mitos P-Pump? 3 Closed-loop flow control 4 Product specifications 5 Accessories - overview 6 Mitos P-Pump Basic 7 Mitos P-Pump

More information

GC-xt. The most flexible GC /GC-MS liquid sample injector

GC-xt. The most flexible GC /GC-MS liquid sample injector GC-xt Prep and Load Platform The most flexible GC /GC-MS liquid sample injector Environmental Foods/Beverages Consumer Products Forensics Petrochemicals/Polymers Pharmaceuticals GC-xt Liquid mode Prep

More information

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC. Gas Chromatography Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC. Samples in 10mL sealed glass vials were placed in the MPS-2

More information

Wyatt Technology Corporation. The Eclipse. The ultimate system for separating macromolecules, proteins, colloids, and nanoparticles

Wyatt Technology Corporation. The Eclipse. The ultimate system for separating macromolecules, proteins, colloids, and nanoparticles Wyatt Technology Corporation The Eclipse AF4 The ultimate system for separating macromolecules, proteins, colloids, and nanoparticles The Eclipse AF4 The ultimate system for separating macromolecules,

More information

INSTRUCTIONS 56-1190-98. Edition AC

INSTRUCTIONS 56-1190-98. Edition AC Sephacryl S-100 High Resolution Sephacryl S-200 High Resolution Sephacryl S-300 High Resolution Sephacryl S-400 High Resolution Sephacryl S-500 High Resolution INSTRUCTIONS Sephacryl High Resolution chromatography

More information

Filter Vials. Product Knowledge. PTFE PVDF Nylon PES. Pat. US #7,790,117 Worldwide patents pending. Thomson Instrument Company Toll Free 800 541.

Filter Vials. Product Knowledge. PTFE PVDF Nylon PES. Pat. US #7,790,117 Worldwide patents pending. Thomson Instrument Company Toll Free 800 541. Product Knowledge Filter Vials PTFE PVDF Nylon PES.2µm.45µm.2µm.45µm.2µm.45µm.2µm.45µm Pat. US #7,790,117 Worldwide patents pending Thomson Instrument Company Toll Free 800 541.4792 Email [email protected]

More information

Innovative vs Traditional

Innovative vs Traditional And in the red corner, introducing the challenger NASDAQ April 4 2011 243.47 $ 1.38 $ 0.58 % 0.07 $ 0.02 $ 39.4 % Technology DVD Digital Streamline Instant Play Internet Access Unlimited Selection No Late

More information

ChromQuest 5.0 Chromatography Data System

ChromQuest 5.0 Chromatography Data System ChromQuest 5.0 Chromatography Data System User Guide for the Surveyor LC CHROM-97257 Revision A March 2008 2008 Thermo Fisher Scientific Inc. All rights reserved. Surveyor and ChromQuest are trademarks

More information

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water Sjaak de Koning 1, Mark van Lieshout 2, Hans-Gerd Janssen 2 and Wil van Egmond 1 1 ATAS, De Run 4334, PO Box

More information

Appendix 5 Overview of requirements in English

Appendix 5 Overview of requirements in English Appendix 5 Overview of requirements in English This document is a translation of Appendix 4 (Bilag 4) section 2. This translation is meant as a service for the bidder and in case of any differences between

More information

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder Lecture Chromo-3: Gas Chromatography CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder Outline Introduction Instrument overview Carrier gas Sample

More information

A Complete Solution for Method Linearity in HPLC and UHPLC

A Complete Solution for Method Linearity in HPLC and UHPLC Now sold under the Thermo Scientific brand A Complete Solution for Method Linearity in HPLC and UHPLC Frank Steiner, Fraser McLeod, Tobias Fehrenbach, and Andreas Brunner Dionex Corporation, Germering,

More information

Gas Chromatography Liner Selection Guide

Gas Chromatography Liner Selection Guide Gas Chromatography Liner Selection Guide Peter Morgan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20551 Key Words Liner, focus Abstract The liner serves an important function in allowing

More information

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates Paula Hong and Kenneth J. Fountain Waters Corporation, 34 Maple St., Milford, MA, USA APPLICATION

More information

Chemical Structure of the polymer showing end groups: CH 3 CH 2 CH H

Chemical Structure of the polymer showing end groups: CH 3 CH 2 CH H Polymer Reference Materials-Polystyrene Introduction Reference materials are used for calibration and performance evaluation of instruments used as part of overall quality assurance programs of polymer.

More information

Analysis of Vegetable Oils by High Performance Liquid Chromatography

Analysis of Vegetable Oils by High Performance Liquid Chromatography Analysis of Vegetable Oils by High Performance Liquid Chromatography Using Evaporative Light Scattering Detection and Normal Phase Eluents Andrew J. Aubin, Cecilia B. Mazza, Donald A. Trinite, and Patricia

More information

Split / Splitless Injection for Capillary GC

Split / Splitless Injection for Capillary GC Split / Splitless Injection for Capillary GC Speakers John V Hinshaw CHROMacademy GC Dean GC Connections editor Moderator Tony Taylor CHROMacademy Trainer Technical Director, Crawford Scientific Dave Walsh

More information

Application Note. Purifying common light-chain bispecific antibodies using MCSGP. Summary

Application Note. Purifying common light-chain bispecific antibodies using MCSGP. Summary Application Note Purifying common light-chain bispecific antibodies using MCSGP Category Matrix Method Keywords Analytes ID Continuous chromatography, biochromatography Antibodies MCSGP Bispecific antibody,

More information

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs Thermo Scientific Prelude SPLC System FPO Making LC/MS accessible to clinical research and toxicology labs Specifically designed to make the power of LC/MS accessible Analysis of target compounds in complex

More information

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS EKSIGENT EKSPERT NANOLC 4 Unmatched flexibility for low flow LC/MS EKSIGENT EKSPERT NANOLC 4 Focused ekspertise In 23, Eksigent changed the way scientists looked at nanoscale chromatography with the introduction

More information

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension International Journal of PharmTech Research CODEN (USA): IJPRIF ISSN : 0974-4304 Vol.2, No.2, pp 1634-1638, April-June 2010 Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination

More information

How To Test For Contamination In Large Volume Water

How To Test For Contamination In Large Volume Water Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples Keywords Application Note ENV0212 This collaboration study was performed

More information

ÄKTA system Training Guide

ÄKTA system Training Guide ÄKTA system Training Guide Explorer 00 / 0 amersham bioscience amersham bioscience amersham bioscience amersham bioscience ÄKTAexplorer ÄKTAexplorer Buffers Injector Box amersham bioscience Monitor Conductivity

More information

designed to never let you down PerkinElmer Series 200 HPLC Systems

designed to never let you down PerkinElmer Series 200 HPLC Systems designed to never let you down PerkinElmer Series 200 HPLC Systems an inside look at the Series 200 HPLC systems PerkinElmer knows you need to rely on your high performance liquid chromatography (HPLC)

More information

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008) Method OIV-MA-AS313-22 Type II method Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008) 1. Introduction

More information

Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC

Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC Abstract: High performance liquid chromatography (HPLC) was used to determine the identity and concentrations of food dyes

More information

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research J. Jones, J. Denbigh, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20581 Key Words SPE, SOLA,

More information

Application Note. Separation of three monoclonal antibody variants using MCSGP. Summary

Application Note. Separation of three monoclonal antibody variants using MCSGP. Summary Application Note Separation of three monoclonal antibody variants using MCSGP Category Matrix Method Keywords Analytes ID Continuous chromatography, Biochromatography; FPLC Protein A-purified monoclonal

More information

Gel Filtration Standard

Gel Filtration Standard Gel Filtration Standard Instruction Manual Catalog # 151-1901 Table of Contents Section 1 Introduction... 1 1.1 Instructions... 1 1.2 Recommended Volume of Standard... 2 1.3 Shelf Life... 5 1.4 Storage...

More information

Designed for multi-injector endurance testing, the

Designed for multi-injector endurance testing, the Designed for multi-injector endurance testing, the ETB Test Bench can optionally provide shot-to-shot mass measurement. The injectors are precisely subject to variable controls and hydraulic pressures

More information

Lecture 24 - Surface tension, viscous flow, thermodynamics

Lecture 24 - Surface tension, viscous flow, thermodynamics Lecture 24 - Surface tension, viscous flow, thermodynamics Surface tension, surface energy The atoms at the surface of a solid or liquid are not happy. Their bonding is less ideal than the bonding of atoms

More information

Enhancing Utility and Throughput of SPME using Advanced Automation Strategies

Enhancing Utility and Throughput of SPME using Advanced Automation Strategies Supelco Innovation Seminars November 11 th, 2010 Atlanta, GA Enhancing Utility and Throughput of SPME using Advanced Automation Strategies Presented by Tom Tobien, Ph.D. Analytical Chemist, LEAP Technologies,

More information

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port APPLICATION NOTE Gas Chromatography/ Mass Spectrometry Authors: Andrew Tipler Sheila Eletto PerkinElmer, Inc. Shelton, CT The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory

More information

Background Information

Background Information 1 Gas Chromatography/Mass Spectroscopy (GC/MS/MS) Background Information Instructions for the Operation of the Varian CP-3800 Gas Chromatograph/ Varian Saturn 2200 GC/MS/MS See the Cary Eclipse Software

More information

1 Four Robotic Platforms to Choose From. 2 Custom Solutions. 3 Do-It-Yourself Robotics

1 Four Robotic Platforms to Choose From. 2 Custom Solutions. 3 Do-It-Yourself Robotics Custom Laboratory Robotics Eclipse Workstation With four robot styles and multiple software options, J-KEM is uniquely positioned to offer custom robotic solutions for virtually any lab automation need.

More information

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax. Standard Method for Analysis of Benzene and Toluene Content in Hydrocarbon Waxes by Headspace Gas Chromatography EWF METHOD 002/03 (Version 1 Reviewed 2015) 1 Scope 1.1 This test method covers the qualitative

More information

EQuan MAX Getting Connected Field Service Guide

EQuan MAX Getting Connected Field Service Guide EQuan MAX Getting Connected Field Service Guide This guide provides procedures to connect the various components for the Thermo Scientific EQuan MAX automated high-throughput LC-MS system. Contents Hardware

More information

Dionex ICS-1100 Ion Chromatography System

Dionex ICS-1100 Ion Chromatography System IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Dionex ICS-1100 Ion Chromatography

More information

Introduction to HPLC. Basic Module in Bioorganic Chemistry January 16, 2007 Johannes Ranke. Introduction to HPLC p.1/17

Introduction to HPLC. Basic Module in Bioorganic Chemistry January 16, 2007 Johannes Ranke. Introduction to HPLC p.1/17 Introduction to HPLC Basic Module in Bioorganic Chemistry January 16, 2007 Johannes Ranke Introduction to HPLC p.1/17 Sources R. Kellner, J.-M. Mermet, M. Otto, H. M. Widmer (Eds.), Analytical Chemistry,

More information

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process Save Hours in Sample Preparation Reduce the time to prepare and inject samples

More information

Temperature. LumaSense Technologies, Inc. supplies a unique selection of very precise calibration

Temperature. LumaSense Technologies, Inc. supplies a unique selection of very precise calibration Temperature Calibration Sources Highly accurate calibration equipment for pyrometers, thermal imaging cameras, radiometers, heatflux and spectrographic measurement sytems. Calibration sources are infrared

More information

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY 9.1 POLICY This test method may be used to confirm the presence of zolpidem (ZOL), with diazepam-d 5 (DZP-d 5 ) internal standard, in

More information

for IonSwift TM MONOLITH ANION CONCENTRATOR (MAC)

for IonSwift TM MONOLITH ANION CONCENTRATOR (MAC) for IonSwift TM MONOLITH ANION CONCENTRATOR (MAC) IonSwift MAC-100 & MAC-200 Product Manual Page 1 of 16 PRODUCT MANUAL for IonSwift TM MONOLITH ANION CONCENTRATOR (MAC) MAC-100, 0.5 x 80mm (P/N 074702)

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

Fractional Distillation and Gas Chromatography

Fractional Distillation and Gas Chromatography Fractional Distillation and Gas Chromatography Background Distillation The previous lab used distillation to separate a mixture of hexane and toluene based on a difference in boiling points. Hexane boils

More information

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography) ACETA.02-1 ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography) PRINCIPLE Isovaleraldehyde (IVA) and acetaldehyde are released from the syrup with the aid of dilute phosphoric acid and heat. The liberated

More information

Innovation and Progress in Water Treatment Technology

Innovation and Progress in Water Treatment Technology Innovation and Progress in Water Treatment Technology Degree of separation of ultrafiltration Summary of the various processes The water will be pressed through the between the raw water side and the filtrate

More information

FORMATION DAMAGE AND WELL TREATMENT SYSTEM

FORMATION DAMAGE AND WELL TREATMENT SYSTEM FORMATION DAMAGE AND WELL TREATMENT SYSTEM FDWTS-10K Includes ability to test Liquid Permeability & Gas Permeability Fines migration & critical velocity Static Filtration Drilling mud invasion evaluation

More information

Thermo Scientific Barnstead TII Pure Water Systems. Pure water. Pure research. Total confidence.

Thermo Scientific Barnstead TII Pure Water Systems. Pure water. Pure research. Total confidence. Thermo Scientific Barnstead TII Pure Water Systems Pure water. Pure research. Total confidence. Thermo Scientific Barnstead TII Pure Water Systems Ideal for any daily application needs for pure water,

More information

ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC)

ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC) ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC) 1 Fast Analysis of C1 to C8 hydrocarbons for mud logging applications within 2 minutes using a temperature programmable Micro GC Fusion NEN GAS2015 Debbie

More information

Material test chamber with mechanical convection

Material test chamber with mechanical convection FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and

More information

Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems

Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES FIMS 100 and 400 Flow Injection Mercury Systems Delivering the Performance You Need The determination and monitoring of sub-ppb concentrations

More information

Washing. Sterilising. Filling. Closing. Inspecting. Labelling

Washing. Sterilising. Filling. Closing. Inspecting. Labelling Washing. Sterilising. Filling. Closing. Inspecting. Labelling Washing Page 4/5 Sterilising Page 6/7 Filling Page 8/9, 10/11 Closing Page 8/9, 10/11 Inspecting Page 12/13 Labelling Page 14/15 Syringe processing

More information

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns Product Manual for SolEx TM HRP Cartridges and SolEx TM HRP RSLC Columns Page 1 of 15 Product Manual for SolEx TM HRP Cartridges SolEx HRP (P/N 074400)

More information

The Theory of HPLC. Gradient HPLC

The Theory of HPLC. Gradient HPLC The Theory of HPLC Gradient HPLC i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference manual. Aims

More information

ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES

ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES The Gold Standard Cardiovascular QUADROX PLS and ROTAFLOW 3 QUADROX PLS AND ROTAFLOW INNOVATIVE PERFORMANCE AND RELIABILITY

More information

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method G8 GALILEO High-End Melt-extraction Analyzer Innovation with Integrity Inert Gas Method Determination of O, N and H The market demands Metals, minerals, and inorganic compound markets demand high-quality

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

endless One platform possibilities for DNA, RNA, protein and cell analysis Agilent 2100 Bioanalyzer Our measure is your success.

endless One platform possibilities for DNA, RNA, protein and cell analysis Agilent 2100 Bioanalyzer Our measure is your success. One platform endless possibilities for DNA, RNA, protein and cell analysis Agilent 2100 Bioanalyzer Our measure is your success. products applications software services Agilent 2100 bioanalyzer Applied

More information

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles THERMAL DESORPTION Introduction and Principles Thermal Desorption Thermal desorption is a simple extension of the technique of gas chromatography (GC) It involves the use of heat and a flow of inert gas

More information

Expectations for GC-MS Lab

Expectations for GC-MS Lab Expectations for GC-MS Lab Since this is the first year for GC-MS to be used in Dr. Lamp s CHEM 322, the lab experiment is somewhat unstructured. As you move through the two weeks, I expect that you will

More information

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES SEPTEMBER 2012, V 1.1 4878 RONSON CT STE K SAN DIEGO, CA 92111 858-565 - 4227 NANOCOMPOSIX.COM Note to the Reader: We at nanocomposix have published this

More information

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

Automation of Solid Phase Extraction and Column Chromatographic Cleanup Automation of Solid Phase Extraction and Column Chromatographic Cleanup Haibin Wan Ltd. Problems with Manual Operation 1. Unstable flow rate affects reproducibility and throughput. 2. Not convenient for

More information

University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence)

University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence) University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence) For this laboratory exercise, you will explore a variety of spectroscopic methods used in an analytical

More information

ENrich SEC 70 ENrich SEC 650 High-Resolution Size Exclusion Columns Instruction Manual

ENrich SEC 70 ENrich SEC 650 High-Resolution Size Exclusion Columns Instruction Manual ENrich SEC 70 ENrich SEC 650 High-Resolution Size Exclusion Columns Instruction Manual Catalog numbers 780-1070 780-1650 Please read these instructions before you use ENrich SEC high-resolution size exclusion

More information

Application Note. Determination of Amino acids by UHPLC with automated OPA- Derivatization by the Autosampler. Summary. Fig. 1.

Application Note. Determination of Amino acids by UHPLC with automated OPA- Derivatization by the Autosampler. Summary. Fig. 1. Application Note Determination of Amino acids by UHPLC with automated PA- Derivatization by the Autosampler Category Bio Analysis Matrix - Method UHPLC Keywords Proteinogenic Amino acids, Canonical Amino

More information

Purification of reaction mixtures using flash chromatography.

Purification of reaction mixtures using flash chromatography. Purification of reaction mixtures using flash chromatography. This technical note details the use of ISOLUTE Flash chromatography columns for the purification of reaction mixtures. What is flash chromatography?

More information

Waters 2695 Separations Module

Waters 2695 Separations Module Waters 2695 Separations Module Quick Start Guide 34 Maple Street Milford, MA 01757 71500269503, Revision A NOTICE The information in this document is subject to change without notice and should not be

More information

HPLC Basics, Equipment, and Troubleshooting

HPLC Basics, Equipment, and Troubleshooting HPLC Basics, Equipment, and Troubleshooting HPLC Basics, Equipment, and Troubleshooting explains chromatography in practical terms from the ground up HPLC Basics, Equipment, and Troubleshooting HPLC Basics,

More information

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING PREMIUM HIGH-PRESSURE DRYING HIGH QUALITY COMPRESSED AIR FROM BEKO The quality of your compressed air. RELIABLE The highest level of operational reliability is guaranteed with every product that BEKO manufactures.

More information

Technical Note. Roche Applied Science. No. LC 19/2004. Color Compensation

Technical Note. Roche Applied Science. No. LC 19/2004. Color Compensation Roche Applied Science Technical Note No. LC 19/2004 Purpose of this Note Color The LightCycler System is able to simultaneously detect and analyze more than one color in each capillary. Due to overlap

More information

An In-Gel Digestion Protocol

An In-Gel Digestion Protocol An In-Gel Digestion Protocol This protocol describes the digestion of a protein present in an SDS-PAGE gel band with trypsin. The band can be taken from either a 1D or 2D electrophoresis gel. Reagents

More information

All the prepared formulations were subjected for following. evaluation parameters and obtained results were showed in Tables 6.3 &

All the prepared formulations were subjected for following. evaluation parameters and obtained results were showed in Tables 6.3 & 105 6.1 CHARACTERIZATION OF TABLETS All the prepared formulations were subjected for following evaluation parameters and obtained results were showed in Tables 6.3 & 6.4. 6.1.1 Description (Size, Shape,

More information

MOLECULAR DRAG PUMPS MDP SERIES

MOLECULAR DRAG PUMPS MDP SERIES MOLECULAR DRAG PUMPS MDP SERIES MOLECULAR DRAG PUMPS MDP SERIES If you need: to replace a rotary vane pump with a dry pump for an application at 10-3 a turbopump that can operate up to 10 a pump that can

More information

KR25i HIGH SPEED, HIGH CAPACITY REFRIGERATED CENTRIFUGE AUTO-LOCK. CQCS Traceability System VIDEOset Display!

KR25i HIGH SPEED, HIGH CAPACITY REFRIGERATED CENTRIFUGE AUTO-LOCK. CQCS Traceability System VIDEOset Display! KR25i HIGH SPEED, HIGH CAPACITY REFRIGERATED CENTRIFUGE AUTO-LOCK CQCS Traceability System VIDEOset Display! A CENTRIFUGE FOR ALL YOUR HIGH SPEED APPLICATIONS CLINICAL BIOLOGY, RESEARCH, INDUSTRY The KR25i

More information

Protein Separation Technology

Protein Separation Technology [ ] Protein Separation Technology Protein Separation Technology The analysis and characterization of protein samples requires the detection of small chemical differences between large molecules. Most often

More information

HiTrap Heparin HP, 1 ml and 5 ml

HiTrap Heparin HP, 1 ml and 5 ml Instructions 71-7004-00 AU HiTrap affinity columns HiTrap Heparin HP, 1 ml and 5 ml HiTrap Heparin HP is a prepacked ready to use, column for preparative affinity chromatography. The special design of

More information

Oasis HLB Cartridges and 96-Well Plates

Oasis HLB Cartridges and 96-Well Plates CONTENTS I. INTRODUCTION II. SAMPLE PRE-TREATMENT a. Biological Samples b. Solid Samples: Soil, Whole Foods, Tissue c. Aqueous Samples: Water, Beverages d. Non-Aqueous Liquid III. SOLID PHASE EXTRACTION

More information

How to reduce the cure time without damaging the rubber compound during injection molding?

How to reduce the cure time without damaging the rubber compound during injection molding? How to reduce the cure time without damaging the rubber compound during injection molding? 0Introduction This article aims at analyzing the rubber injection process and highlighting the limits that prevent

More information