Soil & Waste. Design & installation. Now includes: PVCu dblue HDPE. marley.co.uk MARLEY AKATHERM HDPE
|
|
|
- Gregory Byrd
- 10 years ago
- Views:
Transcription
1 Soil & Waste Design & installation Now includes: PVCu dblue HDPE marley.co.uk MARLEY AKATHERM HDPE
2 Innovation & Expertise Marley Soil & Waste systems Marley Plumbing & Drainage offer a comprehensive range of soil and waste systems. Available with a variety of jointing methods, Marley products are manufactured to exacting UK and European standards and are designed for use on commercial projects as well as housing developments. Product specification information This guide contains design and installation information for Marley PVCu soil & waste, HDPE and dblue acoustic drainage systems. Product specification information on these product ranges is available as a separate document. All documentation can be downloaded from marleypd.co.uk Production information Information on the complete range of Marley Plumbing and Drainage system solutions is available to download from marleypd.co.uk or via the literature hotline BS EN ISO 9001:2008 BS EN ISO 14001:2004 Contents 4 PVCu soil & waste systems 5 Commercial applications 6 Key components Design 8 Stack design 11 Design of waste systems 12 Waste traps 12 WC manifold system 14 Durgo air admittance valve 15 Fire protection Installation 16 PVCu jointing techniques 17 Pipe support 18 Marley dblue 19 Pipe support system 20 Boss branches 20 Boss pipe connections 21 WC connections 22 WC manifold system 23 Site work 24 HDPE jointing methods 31 HDPE installation 35 HDPE handling and storage 36 British & European Standards 37 Marley system solutions 2 MARLEY AKATHERM HDPE MARLEY Soil & Waste Systems 3
3 PVCu soil & waste systems Roof terminal SV42 88½ bend KB2 Bottle trap B040R Commercial applications 82, 110 and 160mm push-fit and solvent weld soil systems incorporating socketed and plain ended pipe s for all BS WC pans. Available with solvent weld or push-fit joints. WC manifold system allows ranges of toilets to be connected horizontally. Ideal for commercial applications. 50 and 82mm floor outlet components are available as separate components or as an all in one trapped floor outlet. Fire sleeves and pipe wraps, providing up to 4 hours rating. 110 and 160mm pipe support components designed specifically to meet the needs of supporting horizontal or vertical suspended PVCu pipework. Weathering slate SAS45 Pipe clip SC45 Pipe SL403 Branch SY401 Bent pan connector SWCB90 Pipe KP tee KT21 Boss connector SA421 Collar boss SCB41 Marley Akatherm HDPE The Marley Akatherm HDPE drainage range is certified to BS EN 1519: 2000 (licence number KM ) An extension of the Marley soil & waste portfolio, the HDPE range offers an alternative solution to cast iron. It is particularly suited for commercial applications or where a product with high impact or abrasion resistance is required, such as hospitals, hotels, schools, as well as residential buildings. HDPE will also cope with temperature variations of -40 C to 100 C. The combination of the excellent material properties of HDPE with homogenous welded joints provides greater installation flexibility with a wide range of jointing options Low level bath trap P , 110 and 160mm pipes and fittings are also suitable for use as internal and external rainwater pipes to drain flat roofs and metal gutter systems on commercial and industrial buildings. P trap P040 Waste pipe Key fitting: Akavent aerator Boss pipe SW40 Pipe SP403 Boss connector SA421 The need for secondary venting in high-rise buildings can be eliminated with the Akavent aerator. An Akavent aerator fitting breaks the fall on each floor and as a consequence the secondary vent pipe is not required as the pressure difference stays well within the limit of 3 mbar. The unique shape of the fitting increases the capacity of the stack. The soil and waste flow from the higher floors smoothly converges with the flow of the lower floor. Slip coupling SE405 Akavent Aerator Underground pipe Marley dblue acoustic system Now available from Solvent waste Push-fit waste Overflow Compression waste Traps PVCu ABS Polypropylene PVCu Polypropylene Polypropylene The Marley dblue acoustic system is a triple-layer drainage system designed for use where improved levels of soundproofing are required. Suitable for use in domestic applications as well as hospitals and hotels, where reduced noise levels are required. Used in conjunction with the acoustic pipe clips, the dblue system is designed to reduce noise and acoustic vibrations to a level of 19dB at 4 l/s discharge rate. It is also lightweight, resistant to temperature change and is jointed using the push-fit ring seal method. The dblue system is available in 40mm, 50mm, and 160mm diameters. It is also compatible with the Marley PVCu soil and waste system for branch connections. *40 mm and 160 mm pipe clips also available. 2 pipe clip diameters*: 50 mm 110 mm Pipe clip fastening Secure fixing to the building s structure. Elimination of the acoustic bridge between the soil stack and the building s structure Suitable for internal and external applications. Lightweight and cost effective for internal installation. Easy to cut joint and install. For internal use, ideally suited to fast installation. Cost effective solution where systems are being installed or modified. A complete range of pipework and fittings for overflow and boiler condensate applications. Multi-fit compression socket, for internal use. Easy installation to similar sized new or existing plastic and copper pipework. A range of traps, which enable quick & easy installation to any new or existing plastic or copper pipework. Solvent soil Acoustic inlays Suppression of vibrations between the system section Three contact surfaces with the pipe Special structure on the noise suppression surfaces Available in 32, 40 and 50 mm Available in 32, 40 and 50 mm Available in 32, 40 mm Available in 21.5 mm Available in 32, 40 mm Available in 32, 40 and 50 mm White & Black White, Black & Grey White, Black & Grey White White & Chrome White & Chrome ABS and polypropylene waste pipes and fittings are designed for internal use and should not be fitted externally as they will be subject to ultraviolet light degradation. If fitted externally it is recommended that they are protected by the application of a suitable paint or are boxed in. The Marley PVCu soil range has been extended with the addition of nine solvent fittings, offering further options for the installer. The range includes the new 8-way soil manifold which offers the flexibility of 4 top and 4 side entries, allowing for multiple inlet connections. At just 70mm above the floor slab, the manifold sits neatly at finished floor level in most typical applications. 4 MARLEY Soil & Waste Systems MARLEY Soil & Waste Systems 5
4 Key components The Marley soil & waste range offers an extensive choice of standard fittings for commercial and domestic projects. Pictured is a selection of key components within the range. Product specification information on the PVCu, HDPE drainage and dblue acoustic soil ranges is available as a separate document. All documentation can be downloaded from marleypd.co.uk PVCu Soil Push-fit or solvent weld Marley co-ex soil soil pipe with at least 30% recycled content 8-way collar boss The collar boss offers the flexibility of 4 top and 4 side entries, allowing multiple inlet connections. Specifically designed to prevent cross-flow and to allow multiple low level bath or shower waste pipes to be connected to the stack above floor level. Adjustable bends Available in 82, 110 and 160mm and can be adjusted by cutting the fitting at the required angle and solvent welding the two sections together. Code Angle achieved Push-fit soil range The Marley range offers a quick, straightforward solution. In up to three colour variants, pipe with a socket or spigot end and a wide range of fittings. Ideally suited for domestic and small commercial applications. Marley soil pipe now combines the environmental benefits of using recycled material with the quality and aesthetic advantages of co-extrusion technology. SB ½ SB SB SB BS EN 1329 certified Looks better, with higher gloss levels Has improved weathering performance Available in grey and black colour only Same list price as standard white pipe Colour matched to all standard Marley soil fittings Solvent Soil range 5 boss branch, 87½ push-fit sockets/spigot The Marley range of five boss branches are designed to allow multiple waste pipe connections to be made to the discharge stack from different directions. Four different side entry combinations are possible together with a rear, if required. Fire protection systems Universal fire collar (UFC1) & fire sleeves Fire sleeves and pipe wraps, providing up to 4 hours rating. The universal fire collar is designed to be surface mounted and is sufficient for 5 x pipe collars. s Connectors for all BS WC pans to accommodate a range of outlet sizes between 84 and. Available with solvent weld or push-fit joints. Durgo air admittance valve The Durgo valve is designed to reduce the number of roof penetrations. Suitable for use in sanitary pipework systems up to ten storeys high, the valve must be fitted in a vertical position above the flood level of the highest appliance connecting to the stack. Manifold system For use in sanitary pipework systems in schools, hospitals, public and commercial buildings, the manifold system allows ranges of toilets to be connected to a horizontal float above floor level and eliminates the need for specially fabricated fittings. The Marley range offers a secure method of jointing and includes the new eight-way collar boss for multiple connections to the stack, solvent socket bends, branches and access fittings. Ideally suited for commercial and horizontal pipework situations. 6 MARLEY Soil & Waste Systems All documentation is available to download from marley.co.uk Technical hotline: MARLEY Soil & Waste Systems 7
5 Design Sanitary pipework design All sanitary pipework systems should be designed to satisfy the following regulations and standards where applicable. The Building Regulations 2010: Approved Document H, Section 1. The Building Standards Technical Handbook (Scotland) 2010: Part M. The Building Regulations (Northern Ireland) 2000, Technical Handbook N. BS EN 12056: 2000, Parts 1 to 5. Regular consultation is essential between Architects and Plumbing Engineers throughout the building design stage as the careful arrangement of kitchen and bathroom appliances will simplify the final sanitary pipework layout. This will help to ensure that an efficient sanitary pipework system is installed at minimum cost. The design information provided in this catalogue is endorsed in the above publications and while every effort has been made to ensure accuracy, no responsibility can be accepted for errors or omissions. For detailed guidance please consult the relevant documents referred to above. Bends at the base of stacks Bends at the base of vertical stacks should be of long radius and have a minimum centre line radius of 200mm on a nominal size stack. Two 45 radius bends may also be used as an alternative to provide the change of direction and connection to the building drain. The same design principle should also be adopted where offsets occur in stacks of one or more storey height. Where pipework is suspended in a ceiling void or car park, it is recommended that two 45 solvent weld bends are used with a short piece of pipe between to ensure the radius exceeds that required. long radius bend UBL488 min 200mm radius Methods of jointing While the principal method of jointing 82, 110 and 160mm PVCu pipes and fittings is push-fit, many components in the PCVu range are also available with sockets that allow for solvent weld jointing. This particular technique is widely used on smaller diameter waste and overflow pipework although expansion and copper adaptor couplings include a push-fit joint to allow for thermal movement. As polypropylene cannot be solvent welded, the push-fit method of jointing is used throughout the system. Marley dblue is a push-fit acoustic drainage system HDPE can be jointed using one of the following methods: Electrofusion; Butt welding; Plug in, expansion or flange joints. solvent weld joint push-fit joint Branches at the base of stacks For single dwellings up to three storeys high, the distance between the centre line of the lowest branch connection and the invert of the drain should be at least 450mm. For multi-storey systems up to five storeys high, the minimum distance should be 740mm and for systems higher than five floors no connections are permissible at ground floor level. Where this occurs a separate stub stack should be provided to serve the ground floor or individual appliances should have their own separate connection to the building drain. SWS415/41 boss pipe L UBL488 or 2 UB455 bends Thermal movement The coefficient of linear expansion for PVCu is 0.06mm/m/ C. As a result a 3m length of pipe will increase in length by approximately 3.6mm when subjected to a 20 C temperature variation. Therefore, it is important to ensure that any movement is controlled and push-fit joints are installed to accommodate any expansion that may occur due to increases in ambient temperature or hot water discharges. L = 450mm up to three storeys high L = 740mm up to five storeys high L = one storey height, over five storeys Sizing of soil stacks Material and manufacture Dimensions and weights It is recommended that the guidance given within BS EN 12056, part 2 be adopted when sizing soil stacks. Marley Technical Services Department offer design and installation advice, including the sizing of soil stacks, for customers who use or specify Marley Plumbing & Drainage products. Soil stack capacity The capacity of a soil stack can be increased by the installation of a secondary ventilated stack. The following information is taken from tables 11 & 12 of BS EN : 2000 which illustrates this increase. Primary ventilated stack Stack size (mm) Maximum capacity (l/s) Swept entries Secondary ventilated stack Stack size Secondary vent Maximum capacity (l/s) (mm) (mm) Swept entries Secondary ventilated stack Marley Plumbing & Drainage pipes and fittings for domestic sanitary pipework systems are manufactured from different plastics materials including PVCu, PVCc, ABS and Polypropylene. The table right details the important dimensions and weights of each of the systems together with the relevant British and European Standard. All pipes are manufactured using a continuous extrusion process and fittings are produced by high-pressure injection moulding. Chemical and temperature resistance Most plastics used for sanitary pipework are highly resistant to those chemicals normally found in domestic waste water and sewerage systems. For applications where chemical discharges are likely to occur, the Marley Akatherm HDPE drainage range may be more suitable. Generally the maximum working temperature of Marley PVCu, dblue & HDPE soil and waste systems when subjected to continuous flow is 70 C and 75 C respectively. Higher intermittent discharges of up to 95 C may be accommodated by PVCu, dblue & HDPE provided the period of discharge does not exceed one minute duration. Alternatively, reference can be made to ISO publications TR10358 & TR7620 which provide comprehensive information on chemical and temperature resistance of plastics and rubber materials. Pipe Material Standard BS nominal size (mm/ inch) Min Max Wall thickness (mm) Min Weight kg/metre Soil PVCu BS BS EN Waste 36/1¼ PVC-c 43/1½ BS EN / Waste 36/1¼ ABS 43/1½ BS EN / Waste Polypropylene 34/1¼ BS EN /1½ Overflow PVCu 21.5/¾ BS EN MARLEY Soil & Waste Systems All documentation is available to download from marley.co.uk Technical hotline: MARLEY Soil & Waste Systems 9
6 Design Offsets in stacks Offsets in the wet portion of a discharge stack should be avoided wherever possible but where they have to be fitted a large radius or two 45 bends should be used to create each change of direction. Offsets in lightly loaded stacks up to three storeys high do not require offset venting but on multi-storey buildings this may be necessary depending on the loading of the stack and the numbers of floors above the offset. The principles previously described for bends and branches at the base of a stack should also be applied. Stub waste This technique is often used to connect isolated ground floor waste appliances such as basins, baths, shower trays and sinks to eliminate exposed pipework or low level ducting. The unventilated PVCu drain is terminated at finished floor level with a reducer and boss adaptor to suit the size of waste from the appliance. UB411 bend SA411/421/420 32mm/40mm or 50mm boss connector SRM402 eccentric reducer Stub stacks An unventilated stub stack terminated with an access fitting may be used to connect a group of ground floor appliances to the building drain provided the vertical drop to the invert level of the drain does not exceed 1.5m from a WC and 2.5m from a waste appliance. Where one or more stub stacks are connected to the same drain, the head of the run should be ventilated to atmosphere or air admittance valves fitted to each stub stack arrangement. SWS415/41 boss pipe 2.5m max 1.5m max SE40 access cap SY401 branch long radius bend UBL488 8-way collar boss SY401 Equal Branch Top & side waste connections for maximum flexibility, even in tight spaces. Design prevents any danger of cross-flow. Hole cutter locator Factory fitted, air tested joint ensuring long term integrity. No need for pipe to be cut on site, saving installation time. Comes complete with pre-chamfered spigot tail for easy jointing. SCBL41 350mm Long spigot tail, accommodating virtually all floor thicknesses. SFC44 fire collar, SFW44 pipe wrap can be used within the floor slab. SC41 clip fitted around socket. 61mm Branch pipe gradients The gradient of a branch pipe should be uniform and adequate to drain the pipe and appliance efficiently. A minimum gradient of 18mm/metre should be adopted for 32, 40 and 50mm nominal size pipes but larger diameter 82, 110 and 160mm branch runs may be laid flatter at 9mm/metre fall where the discharge flow rate exceeds 2.5litres/second. Branch pipe lengths The following information is taken from Table 8 of BS EN 12056: 2: 2000 and provides general guidance on the recommended lengths of unventilated branch pipes for a variety of sanitary appliances. Appliances Dia (mm) Min.trap seal depth (mm) Max. length of pipe (m) Pipe gradient (%) Max. bends (No.) Max. drop H (m) Washbasin or bidet Washbasin or bidet to Bath or shower No limit 1.8 to 9.0 No limit 1.5 Bowl urinal to 9.0 No limit 1.5 Trough urinal to 9.0 No limit 1.5 Kitchen sink No limit 1.8 to 9.0 No limit 1.5 Dishwasher or washing machine to 4.4 No limit 1.5 WC No limit 1.8 min No limit 1.5 Crescent flush actuation plate, Multikwik Sanitary Systems The maximum lengths given above may be increased where the branch pipe is ventilated or an air admittance valve is used. For further details refer to the above standard. Prevention of cross-flow Where small diameter branch waste pipes connect to a discharge stack they must be arranged to eliminate the risk of cross-flow from one branch to the other. A branch creates a no entry zone for opposing waste connections, which varies depending on the stack diameter. No connections should be made within the restricted zone although entry is permissible on the centre line of the boundary directly opposite or at right angles. SWS40 boss pipe To prevent cross-flow from a large diameter branch to a smaller waste connection, the latter should be made to the stack at or above the centre line of the larger branch, at right angles or at least 200mm below the restricted zone. Entry is permissible on the boundary centre line directly opposite or at right angles. The Marley Collar Boss was specifically designed to overcome installation problems imposed by the 200mm restricted zone and to allow multiple low level bath or shower waste pipes to be connected to the stack above floor level. Cross-flow is prevented as the circular annular chamber protects the small diameter waste connections from the WC discharge allowing waste water to flow freely and merge below the critical zone. Different combinations of branches can be used with the collar boss to accommodate various WC positions which may be up to 3 metres from the vertical stack. SY401 branch Stack size (mm) Height of zone 'H' (mm) SA421 boss adaptor H SY405 branch H SCB41 collar boss SA421 boss connector H = 200mm irrespective of stack diameter 10 MARLEY Soil & Waste Systems MARLEY Soil & Waste Systems 11
7 Design Combined branch waste A combined branch waste is often used to connect a bath and/or shower and basin to the discharge stack as this allows waste pipework to be neatly concealed in a low level duct. Where this technique is adopted a 45 entry tee must be used to ensure the basin discharge is swept in the direction of flow towards the stack. The minimum distance between the bath or shower and basin connection should not be less than 500mm and it is recommended that an anti-syphon bottle trap is fitted to the basin or a vent provided to protect the appliance from self-syphonage. It is recommended that the distance of the combined waste does not exceed 3 metres, however, experience has shown that longer runs using 40 or 50mm pipework has proved successful provided adequate fall can be obtained to ensure self-cleansing velocity is maintained Waste traps Generally appliances such as sinks, baths and showers do not suffer from self-syphonage as the trap seal is replenished at the end of the discharge due to the flat bottom design of the appliance. Tubular traps are recommended for such appliances as they ensure unrestricted discharge and reduce the risk of blockage and prevent the accumulation of sediment. Compression jointed polypropylene traps can be taken apart to remove a blockage or gain access to the waste system Range includes P-traps, S-traps, bottle traps, bath & shower traps and different configurations for washing machines, dishwashers, 1½ or 2 bowl sinks White with multiple seal depths Sizes: 32, 40 and 50mm B040V anti-vac bottle trap The Multikwik anti-vac bottle trap, B032V / B040V, was specially developed to prevent self-syphonage from basins, which can occur particularly where the waste pipe drops vertically from the appliance before falling at an even gradient to the discharge stack. The trap also eliminates the need for a secondary vent pipe where basins are located further than the recommended 3m maximum from the stack. Non-mechanical, the trap operates as air is drawn in through a by-pass tube to eliminate any syphonic action and ensure the trap seal is maintained. The P1940 low level shallow trap has a 19mm water seal and is supplied to satisfy customer demand. It is recommended its use is restricted to ground floor baths and showers that discharge directly to an external trapped gully. It should not be fitted to a bath or shower where the waste pipe is connected to a soil stack. Now available from WC manifold system Developed for use in sanitary pipework systems in schools, hospitals, public and commercial buildings, the manifold system allows ranges of toilets to be connected to a horizontal float above floor level and eliminate the need for specially fabricated fittings. The components are suitable for installation in a duct, or for fitting on the surface of the wall directly behind the pan. Where the manifold is fitted directly behind the range of toilets, the minimum distance between the end of the WC spigot and the face of the wall is 150mm. To facilitate varying angles and gradients the 110 x 90mm manifold branch has a radial socket to match both options of adjustable WC bend. When the selected bend is cut to the appropriate line and solvent welded into the socket on the manifold branch a uniform fall is obtained between each toilet on the horizontal float. centre line of WC outlet from finished floor level 190mm SM42W & SA323W SM41W To accommodate different dimensions between the WC spigot and horizontal float, the adjustable spigot bend SM43W may be trimmed by up to 35mm or the extension pipe SM45W can be used with the pan connector SM44W and SA323W cap & seal. The WC socket on both the SM42W and SM44W must be trimmed to suit the length of pan spigot before the SA323W is fitted. For installation details see page 18. bath/ shower P1940 low level trap KT21W entry tee KBA22W 45º bend SWS41 boss pipe float at 9mm/metre fall SY401/SY405 branch 500mm min 40mm A SM42W adjustable bend Manifold branch SM41W with SM42W Adjustable wall fixing 215mm minimum duct width Manifold branch SM41W with SM43W B Cut line A projection (mm) B drop (mm) W.C. cistern Flush plate Cut line SA323W cap & seal A projection (mm) SM41W B drop (mm) manifold 123branch 130 front panel W.C. frame SM42W adjustable WC bend SM41W Manifold branch W.C. seal & cap SA323W A SM42W adjustable bend WC bend Flush pipe SM43W WC spigot bend SM41W manifold branch SA323W cap & seal A SM43W SM43W adjustable adjustable spigot bend WC bend JB42 two peice pipe bracket with SC621 barrel clip collar 110 x 90mm branch SM41W Adjustable bend SM42W with socket trimmed to suit 50mm pan spigot SA323W cap cap && seal seal B SM41W manifold SM41W branch manifold branch float JB42 two peice pipe bracket with SC621 barrel clip collar Adjustable bend SM42W with socket trimmed to suit 50mm pan spigot SA323W SA323W cap cap & seal & seal SM44W pan connector SM44W pan connector B SM41W manifold branch SM41W manifold branch 12 MARLEY Soil & Waste Systems MARLEY Soil & Waste Systems 13
8 Design Durgo air admittance valve Fire protection The Durgo valve is designed to reduce the number of ventilating pipes and subsequent roof penetrations in domestic, commercial and public buildings. Suitable for use in sanitary pipework systems up to ten storeys high, the valve must be fitted in a vertical position above the flood level of the highest appliance connecting to the stack. Valves should be installed within the building in a ventilated duct or roof space where there is no risk of freezing and must be accessible for inspection and testing. The 50, 82 and size valves have been assessed by the British Board of Agrément and awarded Certificate No 06/4325 which permits their use in accordance with the Building Regulations. A copy of the full certificate is available and provides comprehensive information on their use and installation. 11 to 20 dwellings SVP at head and mid point When installed the valve will remain closed unless the system is subject to negative pressure whereby the diaphragm will lift and allow air to be drawn in to eliminate syphonic action. Positive pressure ensures the valve closes and prevents foul air escaping from the system. Each valve is supplied boxed with a polystyrene insulation cover that should remain in position after installation, as this will protect the valve against freezing, particularly when installed in a roof space. To ventilate the underground drainage system and to minimise the effects of back pressure should a blockage occur, the branch or main drain serving a stack or stacks fitted with Durgo valves may require conventional venting at a point upstream of the stack connection. 5 to 10 dwellings SVP at head Up to 4 dwellings no SVP required SVP Durgo SVP Durgo Durgo Durgo For up to and including four dwellings, 1, 2, or 3 storeys in height, additional drain venting is not required. Where a drain serves more than four such dwellings equipped with the valve, the drain should be vented according to the following rules: 5 to 10 such dwelling conventional ventilation to be provided at the head of the system. 11 to 20 such dwellings conventional ventilation to be provided at the mid-point and at the head of the system. For multi-storey domestic dwellings (other than those referred to previously) and non-domestic buildings, conventional drain venting should be provided if more than one such building, each equipped with the valves, is connected to a common drain which itself is not vented by means of a ventilating stack or a discharge stack not fitted with a valve. Stacks should not be fitted with valves when the connecting drain is subject to periodic surcharging or is fitted with an intercepting trap. An open vent must be provided and this also applies to stacks that discharge to a cesspool or septic tank. The Building Regulations 1991 (as amended) require that a building shall be sub-divided into compartments where necessary to inhibit the spread of fire. Plastics pipework is permitted to penetrate separating walls, compartment walls and floors provided the appropriate measures are taken to prevent the spread of fire in accordance with Part B of the Approved Document (2010). To comply with this, pipes must be enclosed within a fire resistant enclosure which extends from floor to ceiling within each storey. The enclosure must have a class O internal surface and have each side formed by a separating wall, external wall or by casing. Any casing must have a minimum ½ hour fire resistance and penetrations of the duct must be limited to 160mm vertical and horizontal. Where longer periods of fire resistance are required, Marley fire collars or pipe wraps can be fitted to provide a fire rating of up to 4 hours depending on the actual construction detail. Tests carried out at the Warrington Fire Research Centre in accordance with BS 476: Part 20: 1987 verified the integrity of each construction detail shown opposite in respect of fire spread. In addition to the above, tests carried out at FIRTO on a variety of typical sanitary pipework arrangements proved that it was possible to achieve up to 1½ hour fire rating through a compartment floor without a fire collar or pipe wrap where the stack was terminated by an air admittance valve. Various other arrangements were also tested and achieved a minimum of 2 hours integrity. The test work and technical evaluation was independently assessed by the British Board of Agrément who issued an Agrément Certificate. Copies of this original certificate and the detail sheets are available from Marley Plumbing & Drainage. SW40 boss pipe SY401 branch The construction illustrated below achieved a 1½ hour fire resistance rating without the need for a fire resistance enclosure. The enclosure is necessary to achieve a 2 hour rating. SVD4 Durgo air admittance valve SE400 pipe socket SGS41/SA323W WC pan connector 20th 11th 10th 5th 4th 1st Indicative row of 20 dwellings 3 storeys high (maximum) fitted with Durgo valves Floor and enclosure fire stopped at all openings using materials meeting building regulation requirements BASIN FLOOD LEVEL SE400 Coupling or pipe socket SC45 Pipe clip SVD4- B1 rated valve fitted above flood level of basin Fire protection Marley Fire Protection Products provide up to 4 hours resistance. Suitable for use with all Marley plastic drainage systems B032V anti syphon bottle trap KR210 reducer SWCB90 90 connector PVCu pipe SRM x82mm Level invert reducer SVD3-82mm A1 rated valve fitted below flood level of basin mm 40mm dia BATH/SHOWER P1940 low level 'p' trap KBA22 45º bend 40mm dia SYS Branch UFC Universal fire collar SFC44 fire collar SFW44 pipe wrap SFC44 fire sleeve SFW44 pipe wrap F.F.L. Universal fire collar fixed to soffit of concrete floor Fire collar fixed to soffit of concrete floor Pipe wrap fixed within concrete floor Fire collar fixed to exposed side of fire compartment wall Pipe wrap fixed within fire compartment wall KT21 45º tee 2no 45 Bend KBA22/KB22 SA421 Boss connector SCBL41 Collar boss 14 MARLEY Soil & Waste Systems MARLEY Soil & Waste Systems 15
9 Installation data Jointing techniques The ring seal has been successfully employed as the principal method of jointing large diameter PVCu pipes and fittings since their introduction over thirty years ago. This particular technique has proved extremely reliable as the joint can accommodate thermal movement that will occur as a result of temperature variations. An expansion gap of between 5-10mm should be allowed within each ring seal socket as each full length of pipe is installed and fixed using socket and barrel pipe clips. Solvent weld jointing is also widely used and many components in the range are available with this facility to provide an effective alternative. By selecting these fittings a solvent weld system can be installed, however, ring seal joints must be incorporated to control thermal movement. While the most popular method of jointing larger size PVCu pipes and fittings is by ring seal, with small diameter waste pipework the principal choice is usually solvent weld. Where this technique is used expansion couplings must be introduced where pipe lengths exceed 2 metres or between fixed points. The same principle should also be adopted when the polypropylene push-fit waste system is installed. It should be noted that polypropylene cannot be solvent welded and together with the ABS waste system must not be fitted externally unless painted to protect it from ultra-violet degradation. Pipe support Experience has proved that an efficient and reliable PVCu sanitary pipework system depends considerably on the attention that is placed on the correct provision of pipe support brackets. This is particularly important in multistorey buildings where care must be taken to ensure clips are positioned to control thermal movement at each floor level. Plastic coated metal socket clips are designed to fit ring seal sockets and act as anchor brackets. These used in conjunction with PVCu intermediate pipe clips, control expansion and contraction and maintain the vertical alignment of the stack. Two piece socket clips SC41/61 may be adapted to suit the appropriate pipe size by using a section of barrel clip collar SC621 to provide the necessary spacer sleeve. The table opposite indicates the maximum recommended support centres of different size plastic pipe systems. ring seal joint solvent weld joint 40mm waste pipe expansion coupling KEC2 pipe clips barrel pipe clip SC45 socket pipe clip SC41 Solvent soil stack installation The addition of the SE409 ring seal adaptor allows for thermal movement required in a solvent soil installation 5 to 10mm Expansion gap 5 to 10mm Expansion gap SES401 Double solvent coupling SC41 SES401 Socket/support clip Double Anchor point solvent coupling SC41 Socket/support clip Anchor point SFS41 Access pipe SFS41 Access pipe Connection from W.C Connection Connection from from W.C bath/shower Connection from bath/shower MAX 2000mm MAX 2000mm SC45 Pipe/barrel clip Guide bracket SC45 Pipe/barrel SE409 clip Guide Ring seal bracket adaptor SE409 SYS405 Ring seal branch adaptor SCB41 SYS405 Collar boss branch SCB41 Collar boss Push-fit soil stack installation 5 to 10mm Expansion gap 5 to 10mm Expansion gap SC41 Socket/support clip Anchor point SC41 Socket/support clip Anchor point SFS41 Access pipe SFS41 Access pipe Connection from W.C Connection Connection from from W.C bath/shower Connection from bath/shower Pipe material BS Nominal pipe size Horizontal support (m) Vertical support (m) PVCu Polypropylene PVCc ABS PVCu MAX 2000mm MAX 2000mm SC45 Pipe/barrel clip Guide bracket SC45 Pipe/barrel clip Guide bracket SY401 branch SC41SY401 Collar boss branch SC41 Collar boss 16 MARLEY Soil & Waste Systems MARLEY Soil & Waste Systems 17
10 Installation data Marley dblue Marley dblue is a push-fit system and is installed in the same way as PVCu soil pipe. The only minor difference is type of clips used, which are integral to the effectiveness of the system. Marley pipe support system The Marley pipe support range was developed to meet the specific requirements of PVCu suspended sanitary pipework and drainage systems. Manufactured in zinc electro plated mild steel for internal use, the versatile range of components can be assembled to provide a robust, lightweight system suitable for most applications. The system also provides suitable control of expansion and contraction. The arrangements of brackets and channel supports have been extensively tested and the assembly techniques used have been successfully employed on many domestic and commercial installations. Single support Drill holes applicable for the diameter of the fixing. Fix a rawlbolt into the wall and insert the pipe clip, rotating it clockwise until it is flush with the wall and secure. Recommended for waste or larger diameter pipework fixed within 500mm of the floor soffit. Double support Developed for use with larger diameter pipework fixed within 1.0m of the floor soffit. Pipe brackets 500mm max. The two piece pipe brackets are designed to fit round the ring seal socket of or a 600mm pipe with or fitting. Where intermediate support brackets are located, the SC621 PVC barrel clip collar side bracing is used as a spacer sleeve between the pipe and bracket. Angle and side bracing Angle braces should be provided at 6m centres to prevent lineal and thermal movement. Side bracing may also be necessary on long runs where there are no side connections to eliminate lateral movement. see table intermediate bracket angle brace pipe anchor bracket Vertical pipes The transition between vertical and horizontal pipework should be achieved using two 45 bends or a single 87½ long radius bend with a support bracket positioned as close as possible. Branch connections Put the pipe or fitting inside the pipe clip under socket and connect the two parts of the open pipe clip with a drill. All branch connections into horizontal pipework should be made at 45 to ensure the discharge is swept in the direction of flow. Structural fixings It is recommended that 6mm rawlbolt or similar proprietary fixings are used to secure base plate and angle cleats to the structure. 750mm max. or 1.0m with side bracing 1.2m max. angle brace intermediate bracket pipe anchor bracket 1.0m Marley dblue boss connections Single support Double support Marley boss connectors are available in white, black & grey. The blue colour variant is not only a different colour, but it is a different size, which should be used to connect to dblue metric waste pipe only. Please note that this applies to the boss connections on all Marley dblue fittings, including the collar boss, branches and boss pipe. For integrity, all boss adaptors must be solvent welded into boss upstands. SW40BL boss branch SA421BL (40mm) / SA420BL (50mm) dblue boss connector 40mm dblue pipe (PPA D) or 50mm dblue pipe (PPA D) SW40BL boss branch SA411/421/420 boss connector 32, 40 or 50mm pipe ABS or PVCc waste pipe 500mm max. or 600mm with side bracing see table anchor bracket angle brace pipe 1.0m max. or 1.2m with side bracing see table angle brace pipe anchor bracket intermediate bracket intermediate bracket To connect a Marley dblue soil stack to Marley dblue waste pipe, use the SA421BL (40mm) or SA420BL (50mm) To connect a Marley dblue soil stack to Marley ABS & PVCc waste systems use the SA411 (32mm), SA421 (40mm) or SA420 (50mm) in white, black or grey. 1.2m max. angle brace 18 MARLEY Soil & Waste Systems MARLEY Soil & Waste Systems 19
11 Installation data Boss branches The Marley range of five boss branches are designed to allow multiple waste pipe connections to be made to the discharge stack from different directions. Four different side entry combinations are possible together with a rear if required. Staggered waste pipe connections, directly opposite are not permitted as cross-flow could occur. 32, 40 or 50mm pipe SA411/421/420 boss connector ST40W solvent SWCB pushconn Compatibility Boss pipes, boss connectors and strap-on bosses fitted with multi-fit T ring seals are suitable for use with PVCc or ABS waste systems to BS EN 1566 or BS EN , polypropylene to BS EN and metric size copper to BS EN Un-perforated boss upstands on boss pipes, branches and reducers may be drilled to accept 32, 40 and 50mm boss connectors SA411, SA421 and SA420 using a 51mm diameter hole saw. Knuckle bends KBK25 and KBK35 may also be used as 90 boss connectors for 40 and 50mm PVCc or ABS waste pipework. Horizontal connections The SWS4135 boss pipe is recommended for use in horizontal situations where connections to diameter pipe is made at 45. This fitting has a 50mm solvent weld socket to accept PVCc or ABS waste pipes. SY405 branch SA411/421/420 boss connector SY405 branch SA411/421/420 boss connector SY405 branch SY405 branch KBK25 or KBK35 knuckle bend SA411/421/420 boss connector 32, 40 or 50mm pipe WC connections Two different types of connectors are available to allow connection to vitreous china or stainless steel WC pans, slop hoppers and other similar sanitary equipment. Manufactured in PVC and eva (ethylene vinyl acetate) to accommodate a range of outlet sizes between 84 and sanitary pipework or undergound drainage. The 90º ST40W, ST41W and SG40W connectors are supplied complete with flexible seal and retaining cap. Where the SGS41W or STS41W pan connectors are used, the WC socket must be trimmed to suit the length of pan spigot before the SA323W is solvent welded in position. Ground floor toilets often have their own connection to the building drain to eliminate pipework and ducting. Where this occurs both types of connector are suitable for push-fit or solvent weld jointing to the PVC drain. SWCB90 ST40W SGS41W push-fit WC solvent solvent connector SGS41W solvent ST40W solvent SA323W WC seal and retaining cap SA323W WC seal and retaining cap SWCB90 push-fit WC connector SWC11 push-fit SWC11 push-f WC co Boss pipe connections Four different types of fitting are available to provide alternative methods of connecting small diameter waste pipes to 82, 110 and 160mm vertical discharge stacks. Single boss pipes. Available with ring seal or solvent weld sockets for push-fit or solvent weld jointing, single boss pipes allow 32, 40 and 50mm waste pipe connections to be made at 87½ direct to the vertical stack. Multiple entry boss pipes. Supplied in ring seal or solvent weld options, all have 90 boss upstands moulded on each fitting with one inlet port open. Connection is made using the appropriate size Marley boss connector to suit 32, 40 or 50mm waste pipes. SWS415/ SWS41 SW30/40 boss branch SA411/421/420 boss connector 32, 40 or 50mm pipe Strap-on-bosses. Primarily designed to permit 32, 40 and 50mm waste pipe connections to be made to existing PVCu discharge stacks, strap-on-bosses can also be used on new systems to provide flexibility of installation during different stages of construction. Patch bosses. Suitable for solvent weld jointing to new and existing 82mm diameter PVCu discharge stacks to accept 32, 40 and 50mm size PVCc or ABS waste pipework. SWS4150 /410/420 82mm SWS332 /340/350 ST40W solvent SGS41W solvent SWCB90 ST40W push-fit WC solvent connector SGS41W solvent SA323W WC seal and retaining cap ST40W solvent SA323W WC seal and retaining cap SWCB90 SGS41W push-fit WC solvent connector SA323W WC seal and retaining cap SWC11 push-fit PVCu drain SWCB90 push-fit WC connector SWC11 push-fit ST40W solvent ST40W solvent SWC11 push-fit PVCu drain SWCB90 push-fit PVCu drain SWCB90 push-fit WC conne 11 PV SGS41W 20 MARLEY Soil & Waste Systems MARLEY Soil & Waste Systems 21 solvent
12 Installation data Site Work Up to six WCs can be connected to a soil stack using the WC manifold system and a single branch NUMBER ANGLE OF MANIFOLD BRANCH connection. By using a double branch connection, an additional six WCs can be connected. OF WCs WC 1 WC 2 WC 3 WC 4 WC 5 WC 6 The table, right, details the angles of the manifolds for this installation WC manifold system Inspection and testing Inspection and testing should be carried out in accordance with BS 12056: 2000 and Building Regulations noting especially the details given in respect of air testing and the fact that smoke testing of plastics pipework should be avoided as the materials can be adversely affected. Air test The installation should be capable of withstanding an air test of positive pressure of at least 38mm water gauge for at least 3 minutes. During this time every trap should maintain a water seal of at least 25mm. Handling PVCu pipes are strong, though lightweight and therefore very easily handled. However, reasonable care should be exercised while handling, particularly in extremely cold conditions. Pipes should preferably be loaded and unloaded by hand but if mechanical handling is used, protected slings are recommended. Maintenance Provided that the system is designed and installed correctly, no maintenance will be required. If blockage does occur, use only flexible or roller type rods. Pointed or bearing type metal fittings are not recommended. Tests have been carried out on PVCu pipes and fittings using equipment from specialist drain cleaning contractors and their standard equipment is suitable. Safety The relevant regulations are outlined in the Health and Safety At Work Act 1974 and The Construction (Design and Management) Regulations 1994 and should be followed. Hazard sheets, dealing with the correct storage, use, and any hazards of working with solvent cement, silicone lubricant and fire protection products are available from Marley Plumbing & Drainage. Dimension (*) based on 230mm centre outlet WC pans and SM43W adjustable spigot bends cut to the angles shown. 1. Select the adjustable bend angle required from the above diagram according to the WC position. Cut the bend with a hacksaw, removing the unwanted portion. 2. File away any rough edges from the face of the fitting and wipe clean the bend and branch, with a dry cloth. Before jointing, the bend and branch should be checked for position and alignment, both parts being marked to ensure accurate assembly. 3. Apply a uniform coat of Marley solvent cement, to the short branch radial socket and to the external surface of the bend body. SM41 Storage Pipes should be stacked on a reasonably flat, level surface on timber battens not less than 75mm wide spaced at a maximum of 1m centres. Side support should also be provided at intervals of not more than 1.5m. Different size pipes should be stacked separately. However, where this is not possible, larger diameter pipes should be placed at the bottom. Spigot and socket pipes should be stacked separately. However, where this is not possible, larger diameter pipes should be stacked with sockets at alternate ends protruding to ensure pipes are evenly supported along their length. Pipes should not be stacked more than 7 high and when stored in the open for long periods, or exposed to strong sunlight, they should be covered with an opaque sheet. Fittings supplied in cardboard boxes or polythene bags should be stored under cover and kept packed until required. Solvent cement should be stored in a cool place out of direct sunlight and away from any heat source. 4. Assemble the branch immediately, insuring that the marked lines on the fitting coincide. Do not twist the two parts of the branch during this operation, but maintain steady pressure until the spigot of the bend comes to rest against the internal surface of the branch socket. Quickly wipe off any surplus solvent cement from the inside and outside of the completed joint and hold in position for approximately 15 seconds. SM41 SM42/SM43 SM42/SM43 SM42/SM43 SM42/SM43 5. Trim the WC socket to suit the toilet pan spigot length and remove any swarf with a file. Place the seal in the socket, apply a uniform coat of solvent cement about 15mm wide to the outside of the socket and inside the retaining cap. Push onto the socket and wipe off any surplus solvent cement. SM41 SM42/SM43 SA323 cap and seal To accommodate varying dimensions between the WC spigot and the centre line of the horizontal pipe run, the adjustable spigot bend SM43 or extension pipe SM45 can be used with SM44. Packing, storage and transportation specific to Marley dblue In order to facilitate transport and storage, all the fittings are packed in cardboard boxes. Pipes are packed in bundles on pallets. Marley dblue pipes and fittings must not be transported unpacked (in bulk) along with other construction materials to prevent damage during transportation. The pipes must be transported in a horizontal position. During unloading they must be protected against damage, particularly at temperatures below freezing. Never throw, drag or bend pipes and fittings when unloading them. Pipes should be stored horizontally on even surfaces up to 1.5m high. All products should be protected against sunlight. Their outdoor storage time should not exceed 12 months. 22 MARLEY Soil & Waste Systems MARLEY Soil & Waste Systems 23
13 HDPE jointing methods Electrofusion Electrofusion, the most simple and rapid jointing technique, is mainly used on construction sites for a highly efficient method of assembly for pipes, fittings and prefabricated sections. Electrofusion couplers The PE range includes couplers in the diameters 40 to 315 mm. The couplers are extremely suitable for applications in waste water and rainwater drainage, with the following features: 1. Injection molded with excellent dimensional accuracy and stability. 2. One welding indicator on each welding surface for checking both welding connections. 3. Centre stops easy to remove in order to use the coupler as a slideover coupler. 4. Resistance wires fixed to the surface for an optimal heat transfer and therefore a high quality welding connection. 5. Yellow edge surrounding the welding indicators of the diameters 200, 250 and 315 mm for better visibility. Electrofusion control box The Akafusion control box CB315 can not only weld Akatherm electrofusion couplers in the diameter range 40 to 160 mm but also the diameters 200, 250 and 315 mm. The new techniques applied in the electronics (such as integrated circuit boards) and the case material make it a solid and reliable control box. Multiple welding The CB315 is capable of welding several electrofusion couplers simultaneously in the same time that is needed for producing one electrofusion weld. The combined diameters of the couplers to be joined should not exceed 200 mm. For example in the case of a 45 75/50 mm tee, both the diameters 75 mm and the branch 50 mm can be welded at once. Jointing procedure 1. Cut the pipe square The pipe ends must be cut square to ensure that the heating element in the coupler is completely covered by the pipe or fitting. 2. Mark insertion depth + 10 mm This is to ensure that across the full welding zone the oxidised layer will be removed. 3. Scrape pipe and 10 mm mark insertion depth again The outer surface of the pipe (approx. 0.2 mm deep) must be scraped 10 mm for the full distance 10 mmthat will be covered by the coupler to remove any 10 mm surface 'oxidation'. The insertion depth should be marked again to safeguard full insertion. 4. Clean coupler Before assembling the pipes into the coupler ensure that all surfaces are clean and dry. 5. Insert pipe and/or fitting up to pipe stop Ensure that the pipe is pushed as straight as possible into the fitting. 6. Prevent joint movement during welding 10 mm 10 mm 7. Prevent misalignment 8. Prevent coupler from sliding down when installed vertical 9. Prevent load on vertical pipesystem After connecting the cables of the control box the welding process 42 can be commenced by pushing the start button. The CB315 control box adapts the welding time to the ambient temperature. When it is colder than 20 C the welding time is extended and when the ambient 2x temperature exceeds 20 C the welding time is shortened. For welding times and cooling down time see table below. The joint assembly should not be disturbed during the fusion cycle and for the specified cooling time afterwards. KG dimension d 1 system weld time cooling time mm sec min Constant current 5A Constant voltage 220V Don't weld coupler twice 42 KG 2x KG 2x 2x KG Butt-welding Butt-welding is a very economical and reliable jointing technique for making welded joints, requiring only butt-welding equipment. All Akatherm pipes and fittings can be joined by this welding method. Fittings for which a k-dimension is shown in the table can be shortened by not more than this amount. Butt-welding is extremely suitable for prefabricating pipe sections and for making special fittings. Preparations The following guidelines are of importance when making a proper butt-weld: Establish a work space where the jointing can be done without being effected by major weather conditions. Check the equipment functions properly. Welding equipment used on site deserves special attention. The fittings and or pipes need to be aligned in the welding machine. Mis-alignment can be up to 10% of the wall thickness. Clean the heating element before each jointing operation with a lintfree cloth and suitable cleaner (see instructions welding machine). Cut the pipe and/or fitting with a pipe cutter to make the end square. Make sure that once the pipe and/or fitting ends have been machined, they do not get dirty. Do not touch them with your hands. The surface needs to be clear of oil, grease and dirt. Put the pipe parts into the welding machine to facilitate a firm hold during the jointing process. A digital thermometer can be used to check the temperature of the heating plate. The temperature should be checked at several points around the plate and should be between 200ºC and 220ºC. Maximum deviation between points is given in the table. Used surface of heating element for welding diameter d 1 Δttot d 1 = ºC d 1 = ºC Maximum temperature variation heating element 24 MARLEY Soil & Waste Systems MARLEY Soil & Waste Systems 25
14 HDPE jointing methods Welding process The butt-welding of Akatherm HDPE operates according to the following steps: Machining the surface Both sides should be machined until they run parallel. When the machining is finished, open the carriages (the plastic shavings must be continuous and uniform in both sides to weld). Take off the milling cutter. Verify the alignment between the machined surfaces. Remove the plastic shaving. Do not dirty or touch the machined surfaces. Heating up with less pressure HDPE is a good insulator, therefore at this stage it is necessary that the correct heating depth of the pipe ends is obtained. Only a small amount of pressure 0.01 N/mm 2 is required to maintain the contact of the pipe ends with the heating element. The heat will gradually spread through the pipe/ fitting end. The size of the bead will increase a little. The time and pressure needed for this phase can be found in the table on the next page. pressure N/mm 2 HDPE (PE) 0,15 preheating pressure (F o ) welding pressure (F L ) heating pressure (F d ) 0,01 time Machining the surface preheating time heating time changeover time building-up pressure time cooling time Preheating under pressure Press the two ends to be jointed gradually to the heating element until a bead is created. The size of the bead is a good indication that the appropriate pressure and time is used. For pressure and bead size see the table on the next page. Preheating under pressure Obtaining correct heating depth Change over Remove the heating element from the jointing areas and immediately make those areas touch each other. Do not push the pipe ends abruptly onto each other. The removal of the heating element needs to be done quickly to prevent the pipe ends from cooling down. The times for changing over can be found in the table on the next page. Welding and cooling After the jointing areas have made contact they should be joined with a gradual increase in pressure up to the specified value. Keep the specified welding pressure at a constant level during the cooling period. Do not cool artificially. Welding and cooling The welded components can be removed from the machine when 50% of the cooling period has elapsed, providing that this is done carefully, with no load or strain being placed on the joint. The joint must then be left undisturbed for the remainder of the cooling period. Preheating pressure / welding pressure (0,15 N/mm 2 ) Heating pressure (0,01 N/mm 2 ) Diameter Wall thickness Height Changeover Building-up d 1 e welding bead Heating time time pressure time Cooling time mm mm F O /F L N F d N mm sec sec sec min Welding parameters Akatherm HDPE drainage height welding bead In this table the welding parameters can be found for Akatherm HDPE. The exact regulation of the welding machine depends on its mechanical resistance. The tables provided with the machine are to be used for regulating the machine. total time welding process total welding time 26 MARLEY Soil & Waste Systems MARLEY Soil & Waste Systems 27
15 HDPE jointing methods Evaluating the butt-weld joint Plug-in joint Expansion joint The butt-weld can be evaluated using destructive and non destructive evaluation methods. For these evaluations special equipment has to be used. Butt-welds can easily be judged by a visual inspection making this the recommended method for a first evaluation. The shape of the welding bead is an indication for the proper operation of the welding process. Both welding beads should have the same shape and size. The width of the welding bead should approximately be 0.5 x the height. Differences between the beads can be caused by the difference in HDPE material used in the welded components. Despite the differences in welding bead the butt can be of sufficient strength. When there is either insufficient heating up or too low welding pressure there are hardly any beads. In cases like this thick walled pipes often form shrinking cavities. The weld must be classified as "not acceptable". Butt-weld (not acceptable) A plug-in joint is an easy to make, detachable and non pull-tight jointing method. Expansion sockets can absorb length changes of pipes with a maximum length of 5 m. In the next illustration a good weld is shown with a uniform welding bead. At a visual inspection this would be classified as an "acceptable" weld. Jointing process: Jointing process: Butt-weld with even welding beads (acceptable) In the next illustration a cross-section of a regular, round fusion bead, free of notches or sagging is shown. Special attention should be paid to the fact that the collar value 'K' is greater than 0. Cut pipe square and remove burr Cut pipe square and remove burr Cross section of a good butt-weld Mark insertion depth Mark insertion depth Mis-alignment between fittings and pipe can occur for several reasons. Oval pipe ends or irregular necking of the pipe can cause an incomplete fit. If this is less than 10% of the wall thickness the weld can still be clas- sified as "acceptable"(see next illustration). Butt-weld with mis-alignment of pipe (acceptable) Plug in socket: The pipe needs to be inserted in the plug in socket using the full insertion depth. A plug-in joint is not to be used to accommodate the expansion and contraction of a pipe system. An expansion socket counteracts the variation in length caused by the thermal expansion and shrinkage of the pipe. Depending on the ambient temperature the insertion depth varies. The right insertion depth for both 0 C and 20 C is indicated on the expansion socket. The next illustration shows a joint with beads that are too big. The uniformity indicates a good joint preparation. Heat supply and jointing pressure settings, however, are too high. A purely visual assessment would still classify the weld as "acceptable". Chamfer pipe end The pipe-end needs to be chamfered under an angle of 15. To get an even cut and chamfer a chamfering tool should be used. Chamfer pipe end The pipe-end needs to be chamfered under an angle of 15. To get an even cut and chamfer a chamfering tool should be used. Butt-weld with big welding beads (acceptable) Make joint Lubricate the pipe end and insert the pipe up to the marked insertion depth. Make joint Lubricate the pipe end and insert the pipe up to the marked insertion depth. 28 MARLEY Soil & Waste Systems MARLEY Soil & Waste Systems 29
16 HDPE jointing methods HDPE installation Flange joint Contraction sleeve Tempered Pipe The Marley Akatherm HDPE pipe is tempered. This pipe is produced according to the standards EN 1519 and ISO 8770 but has undergone a heat treatment after extrusion. The result is less shrinkage when cooled down from high operational temperature. This gives less stress on joints resulting in a longer life for the pipe system. For the installation of Akatherm PE pipe systems several bracketing systems can be used: Anchor point bracket This method of bracketing is used for rigid installations. The expansion forces are transferred to the building structure. Shrinkage according to EN 1519 (3%) Maximum shrinkage tempered Akatherm pipe (1%) The flanged joint is a detachable joint not that common in soil and waste systems. It is the ideal jointing method to connect the system onto flanged equipment and to install valves. The joint can be made by the following steps: Mount backing ring over pipe or fitting Pipe length after production Support bracket fixed to building structure- brackets must be of sufficient strength to resist forces generated by thermal movement of the PE pipes Electrofusion coupler either side of support bracket Weld stub flange to fitting or pipe Apply seal Mount bolts, nuts and washers and tighten nuts with the bolt torque mentioned in the next table. d 1 (mm) Bolt torque (Nm) A simple transition to other materials than HDPE can be made using the contraction sleeve. The sleeve provides a non pull-tight connection and is installed as follows: Mark insertion depth on the connecting pipe. Connect contraction sleeve to HDPE pipe or fitting using electrofusion or butt fusion. Mount the O-ring in the middle of the insertion zone. Heat up the contraction sleeve evenly with a torch or an industrial heater. Diameters above 125 mm are best heated up using a second heat source. Linear expansion The Marley Akatherm HDPE material has a linear expansion coefficient of mm/mk. We calculate with an expansion of 0.2 mm per meter pipe for every C temperature difference. The total length variation can be calculated as follows: Δl = L x λ x Δt Δl = length change in mm L = total length of pipe λ = linear expansion coefficient Δt = temperature difference in C Example: Pipe 10 metres with a maximum temperature of 60 C and a minimum temperature of -20 C. This results in an expansion of: Δl = 10 x 0,2 x 80 = 160 mm Length changes can be accommodated by the expansion socket which can take up the expansion and contraction of a 5 meter length of pipe for temperatures between -20 C and 70 C. Anchor bracket with 2 electrofusion couplers Art. Nr. 41xx95 Anchor bracket with expansion socket This method of installation is used for flexible installations where the expansion force is not transferred to the building structure. Only the force caused by the internal resistance of the expansion socket is transferred. Support bracket fixed to building structure-brackets to be of sufficient strength to resist forces caused by the internal resistance of the expansion socket Anchor with expansion socket Thermal movement of PE pipework Bolt torque for non-pressure applications Electrofusion The Marley Akatherm products can be welded by electrofusion unless stated differently in the product table. This is the preferred method of on-site jointing. Butt welding and k-dimension All Marley Akatherm products can be welded using this jointing method. Fittings can be shortened by up to the k-dimension (indicated in the specification guide), still allowing butt-welding on a standard butt-welding machine. Guide bracket The guide bracket is used to support the pipe and to prevent the pipe from buckling sideways when in a rigid installation. The pipe can freely move in the bracket. The sliding bracket is used to support the pipe and to prevent the pipe from buckling sideways (snaking). The pipe should be able to move freely in the bracket Guide bracket 30 MARLEY Soil & Waste Systems MARLEY Soil & Waste Systems 31
17 HDPE installation Bracket distance The bracket distances for Akatherm PE pipes are largely dependent on the working temperature of the pipe system. Also the filling rate of the pipe plays a role. A fully filled pipe has a different bracket distance. Horizontal installation with expansion sockets and support trays In this kind of installation the pipe is extra supported by support trays. The distance between the brackets can be larger. The support shells are installed on to the pipe with straps. For distances see table below. Vertical installation: to the wall For the vertical installation the bracketing distance is in general 1,5 times the distance of the horizontal bracketing. There is no separate bracketing distance for immediately in front of the expansion socket because there is no sagging of the pipe and the insertion is always in line. Horizontal pipework with support tray GB= guide bracket LA= bracket distance FP= fixed point LA*= bracket distance for expansion unit B= tray band LBA = spacing for bands d 1 L A L A * LBA Vertical installation GB = guide bracket FP = fixed point LV = vertical support distance Bracket distances for vertical and horizontal PE pipe systems with standard filling m 0.6 m 0.5 m m 0.7 m 0.5 m m 0.9 m 0.5 m m 1.0 m 0.5 m m 1.2 m 0.5 m m 1.5 m 0.5 m m 1.5 m 0.5 m m 1.5 m 0.5 m Bracket distances horizontal installation with expansion sockets and support trays d1 LV m m m m m m m m m m m Horizontal installation with expansion sockets without support trays The bracket directly in front of the expansion socket has a shorter bracket distance (LA*) This makes a better guidance into the expansion socket possible (see image). The bracketing distances for this application can be found in table below. The maximum distance between 2 expansion sockets is 5 m. d 1 L A L A * m 0.4 m m 0.5 m m 0.6 m m 0.7 m m 0.8 m m 1.0 m m 1.0 m m 1.0 m Bracket distances vertical installation with expansion sockets Bracket distances horizontal installation with expansion sockets 32 MARLEY Soil & Waste Systems MARLEY Soil & Waste Systems 33
18 HDPE expansion socket insertion depths HDPE handling and storage 75mm Expansion Socket (S420720) * 40mm Expansion Socket (S400420) Fittings The fittings and electrofusion couplers need to be stored at a dry place. To prevent oxidation and contamination it is recommended to leave the fittings in their original packaging as long as possible. Pipes The high impact strength of Akatherm HDPE provides some protection against damage but care should be taken at all stages of handling, transportation and storage. Storage of loose pipes 200mm Expansion Socket (S402020) Without Protection Plug 90mm Expansion Socket (S420920) * Expansion Socket (S421120) * 50mm Expansion Socket (S400520) 56mm Expansion Socket (S405620) Pipe must be transported by a suitable vehicle and properly loaded and unloaded, e.g. wherever possible moved by hand or mechanical lifting equipment. It must not be dragged across the ground. The storage should be flat, level and free from sharp stones. Bundles Bundled packs of pipe should be stored on clear, level ground with the battens supported from the outside by timber or concrete blocks. For safety, bundled packs should not be stacked more than three high. Smaller pipes may be nested inside larger pipes. Side bracing should be provided to prevent stack collapse. Similar precautions should be taken with fittings and these should be kept packaged until required for use. Tools Tools need to be protected against moisture. Health and safety at work act and COSHH regulations Attention is drawn to the requirement in the UK of this act and to the 1988 Control of Substances Hazardous to Health (COSHH) Regulations. Marley cannot accept responsibility for accidents arising from the misuse of its products because of bad installation or incorrect application. Handling of HDPE has no detrimental health impact. It is recommended, however, that HDPE is not ingested or dust inhaled. 250mm Expansion Socket (S402520) Without Protection Plug Storage of bundles Personal Protective Equipment (PPE) When welding HDPE, molten material is formed, which can cause burns to skin. Appropriated PPE should be worn. Physical contact HDPE is not considered to be a skin irritant. Where HDPE dust is generated by cutting of machining pipe of fittings, powder particles of HDPE dust may cause eye irritation by abrasion. 125mm Expansion Socket (S421220) * 63mm Expansion Socket (S400620) Butt Weld Only Behaviour in Fire HDPE is a flammable material. It has, however, been installed throughout Europe for over 35 years and presents no greater risk of fire propogation than similar plastic based systems when installed in accordance with local regulations. Marley Unicollar firecollars are suitable for use with Akatherm HDPE (up to 200mm) and these should be installed in accordance with the instructions provided. 315mm Expansion Socket (S403120) Without Protection Plug Diameter HDPE Expansion Details Total Length Min. Insertion 20 C 160mm Expansion Socket (S421620) * Max. Expansion Type A (No White Retaining Ring) * Insertion depth and expansion details indicated on fitting Type B (With White Retaining Ring) 40mm 132mm 76mm 56mm Type B 50mm 132mm 76mm 56mm Type B 56mm 132mm 76mm 56mm Type B 63mm 132mm 76mm 56mm Type B 75mm On Fitting On Fitting Type A 90mm On Fitting On Fitting Type A On Fitting On Fitting Type A 125mm On Fitting On Fitting Type A 160mm On Fitting On Fitting Type A 200mm 230mm 120mm Type A 250mm 250mm 125mm 125mm Type A 315mm 270mm 126mm 144mm Type A Lengths Pipe lengths stored individually should be stacked in a pyramid not more that one metre high, with the bottom layer fully restrained by wedges. Where possible, the bottom layer of pipes should be laid on timber battens at one-metre centres. On site, pipes may be laid out individually in strings (where appropriate, protective barriers should be placed with adequate warning signs and lamps). 34 MARLEY Soil & Waste Systems MARLEY Soil & Waste Systems 35
19 Standards Marley system solutions British & European Standards BS EN : 2014 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure PVCu. BS EN : 2000 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure polypropylene. BS EN : 2000 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure polyethylene. BS 4514: 2001 Specification for PVCu soil and ventilating pipes, fittings and accessories. BS EN : 2000 Specification for thermoplastics waste pipe and fittings. BS 5255: 1989 Specification for thermoplastics waste pipe and fittings. BS EN : 2000 Plastics piping systems for soil and waste (low and high temperature) within the building structure ABS. BS 5627: 1984 Specification for plastics connectors for use with horizontal outlet vitreous china WC pans. BS EN 14680: 2006 Specification for adhesives for non-pressure thermoplastics pipe systems. BS EN 681-1: 1996 Elastomeric seals. Material requirements for pipe joint seals used in water and drainage applications. Part 1 vulcanised rubber. BS EN ISO 9001: 2008 Quality systems. Model for Quality Assurance in Design, Development, Production, Installation and Servicing. BS EN ISO 14001: 2004 Environmental management systems. Requirements with guidance for use. Marley HDPE Marley Akatherm HDPE is a drainage system which offers an alternative solution to cast iron. It is particularly suited for commercial applications or where a product with high impact or abrasion resistance is required, such as hospitals, hotels, schools, as well as residential buildings. HDPE will also cope with temperature variations of -40 C to 100 C making it ideal for external as well as internal installations. Marley dblue An acoustic soil and waste range with a triple layered pipe providing quick, hygienic removal of sanitary waste water. The noise generated by the flow of water is dramatically reduced making it perfect for multi-occupancy apartment blocks and high specification developments. Marley waste systems A wide range of PVC-u, ABS and polypropylene waste ranges from 32mm to 50mm and in a variety of colours. Available with polypropylene solvent weld and push fit jointing. Accreditations Marley rainwater Five gutter profiles and three downpipe options provide a rainwater solution for any application. Advanced Life 4 technology on four of the key profiles, coupled with the benefits of the Easyclip and notching capability combine to make the Marley rainwater range the most comprehensive available. Marley underground systems The Marley Plumbing & Drainage range of underground systems include the solid wall range, predominately for round the house drainage and Quantum structured wall range for sewer and highway drainage applications. Marley sustainable drainage The Waterloc250 cell is ideal for use in either an underground infiltration or attenuation system. 96% of the cell volume is available to store water, minimising the extent of excavation required for the installation. The range includes Flowloc, a vortex control device, which controls the rate at which water is discharged to a surface water drain or water course. TO WATER CERTIFIED INDUSTRY SPECIFICATION Certificate No. 06/4325 BS EN : 2000 BS 4514 : 2001 BS EN : 2000 BS 5255: 1989 BS EN : 2000 BS EN : 2000 BS EN : 2000 BS EN ISO 9001: 2008 BS EN ISO 14001: 2004 Marley Equator Equator is ideal for hot & cold water or central heating installations. A tamperproof fitting with a unique grip release mechanism ensuring that the system can only be disassembled through the use of a special de-mounting tool. Equator has been designed to meet the requirements of BS 7291: Parts 1 & 3; Class S. The complete Equator system is backed by a 30 year guarantee. Alutec Alutec offer modern and traditional aluminium rainwater profiles, providing solutions for any type of building. Aluminium has high visual appeal and durability, lasting for 50 years or more. The product portfolio includes Evolve; easy to install, low cost gutter systems in four profiles. The rainwater ranges are complemented by aluminium soffit and fascia systems and roof & floor outlets. Multikwik The Multikwik brand is known and trusted by plumbers for its sanitary frames, cisterns, traps, compression waste systems and market leading range of pan connectors. Complementing the Marley range it provides an excellent solution to modern bathroom design with a wide choice of product options. 36 MARLEY Soil & Waste Systems MARLEY Soil & Waste Systems 37
20 Notes Notes
21 marley.co.uk For general enquiries and details of your nearest stockist please call the customer services department: Tel: To place an order For delivery to England & Wales Fax: For delivery to Scotland Fax: For all estimate requests For Technical advice please call Head Office Lenham, Maidstone Kent ME17 2DE Tel: Fax: Scotland Birkenshaw Industrial Estate Uddingston, Glasgow G71 5PA Tel: Fax: Export Division Lenham, Maidstone Kent ME17 2DE England Tel: +44 (0) Fax: +44 (0) April 2014
Introduction. Contents. General. Materials and workmanship. Diagrams. Other regulations. References
Introduction General This Technical Booklet has been prepared by the Department of the Environment for Northern Ireland and provides for certain methods and standards of building which, if followed, will
Shower and Floor Gullies Channel Drain and Tile Drain SECTION
Shower and Floor Gullies Channel Drain and Tile Drain SECTION 2 Shower and Floor Gullies, Channel Drain and Tile Drain 29 General Information Shower and Floor Gullies McAlpine has responded to market conditions
Soil and waste for high-rise
1.2 Soil and waste systems for high-rise Because skyscrapers are designed evermore extreme, a single stack soil and waste system offers you the possibility to aim higher. Today, whether a consultant or
Hunter Plastics Ltd Nathan Way London SE28 0AE Tel: 0181-855 9851 Fax: 0181-317 7764
CI/SfB (52.9) Xn6 Designated by overnment to issue European Technical pprovals Product THIS CERTIFICTE REPLCES CERTIFICTE No 83/1066 ND RELTES TO THE HUNTER NOUEU IR DMITTNCE LE ND HUNTER NTI-SIPHON UNIT,
Mechanical Services Standard Specification 9.0 - Above Ground Soil, Waste and Ventilation Pipes
Mechanical Services Standard Specification 9.0 - Above Ground Soil, Waste and Ventilation Pipes May 2010 For ROYAL HOLLOWAY UNIVERSITY OF LONDON Prepared For The Estates Division By: Hulley & Kirkwood
INDUSTRY GUIDANCE FOR INSTALLERS ON CONDENSATE DRAINAGE PIPE INSTALLATION. This guidance is endorsed by HHIC members.
1. BACKGROUND INDUSTRY GUIDANCE FOR INSTALLERS ON CONDENSATE DRAINAGE PIPE INSTALLATION This guidance is endorsed by HHIC members. During recent winters the UK has experienced prolonged spells of extremely
This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular
CI/SfB (52.6) In6 September 2005 SW207. Design & Installation Guide. Soil & Waste Systems FOR RESIDENTIAL, COMMERCIAL AND INDUSTRIAL APPLICATIONS
Uniclass JR11 L7313 EPIC B52 X71 CI/SfB (52.6) In6 September 2005 SW207 Soil & Waste Systems Design & Installation Guide FOR RESIDENTIAL, COMMERCIAL AND INDUSTRIAL APPLICATIONS Intelligent Solutions for
Syphonic Roof Drainage
Page 1 T E C H N O L O G Y 2:39 pm Syphonic Roof Drainage P L U M B I N G 23/5/03 A D V A N C E D Prod & Price Gd.for PDF Product Guide SYPHONICS Advanced Roof Drainage Technology Geberit Syphonics Geberit
1. Description. 2. List of Accessories included A B C F G H
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin. The unit will start automatically. Please pay particular attention to the following: Possible danger to
Syphonic Roof Drainage
Syphonic Roof Drainage A D V A N C E D P L U M B I N G T E C H N O L O G Y Design Guide SYPHONICS Advanced Roof Drainage Technology Design, Manufacture and Installation TSB Call Centre, Cardiff. Millenium
Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling
Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling February 2001 contents General Information 3 Inspection 4 New Drain and Vent Installations
Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk
1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance
Top 10+ Mistakes of DWV plumbing design
Top 10+ Mistakes of DWV plumbing design Listed below are the some of the most frequently missed items, noticed by our inspectors, at plumbing rough-in when non-plumbers attempt plumbing design. Most of
Saferand easierinstallation
EN 85-07 Saferand easierinstallation IföSigninstallationsystem andifösignbuilt-incistern www.ifosanitar.com/sign Aneffectivesolution withmanyadvantages. Ifö Sign installation system makes life a little
Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling
PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling October 2014 contents General Information
ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.
1. Description The macerating system of this unit is installed in a case, specifically designed for horizontal outlet spigots. This macerator is manufactured in a factory which is quality certified to
ISSUE 08/08. KEEP INFORMED Look for other Good Idea Leaflets that could help you with your current project.
7648_GIL_074_07_08.qxd:GIL 074 01 06 27/8/08 16:47 Page 1 ISSUE 08/08 74 UNDERGROUND DRAINAGE Wickes stock a wide range of drainage products, whether it s to replace old drainage systems in the event of
Services Enclosures and Protected Shafts - Maintaining Compartmentation
Introduction When a fire resisting element is used to provide fire compartmentation, every opening that allows services to pass through the element must be adequately protected by sealing, or fire stopping
Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector
Plumbing Helpful Hints Residential Construction Bert Polk Plumbing Inspector Lincoln County 2015 Waste and vent fittings Vent 90 medium 90 long 90 1/16 bend,1/8 bend,1/6 bend, medium 90 san tee combination
STATE BANK OF INDIA.
Page 1 of 5 B SANITARY, PLUMBING & DRAINAGE STATE BANK OF INDIA. PROPOSED RURAL SELF EMPLOYMENT TRAINING INSTITUTE AT RAIGARH IN C.G. DIRECTOR'S BUNGALOW SCHEDULE OF ITEMS-PLUMBING AND SANITARY WORK 1
plumbing products guide
plumbing products guide radiator pipe guide & seals A significant development in the drive to reduce air leakage and heat loss. Installations such as that shown are all too common. The detail is poorly
C1/Sfb (52.5) In6 DECEMBER 1999
C1/Sfb (52.5) In6 DECEMBER 1999 When you select a soil or waste system, you need to be sure of its pedigree, convinced of its ability to perform and confident of enduring quality. The excellence of Brett
Prepare a drainage system layout and specification notes for a low- rise building.
STUDENT MATERIALS Prepare a drainage system layout and specification notes for a low- Outcome 1 - rise building. In this outcome you will study the technology of below and above ground drainage systems.
SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
Rooflight INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Rooflight These instructions should be used for: Installing Permanent Trickle Ventilation: Constructing & Waterproofing a Timber Upstand Curb: Installing & Waterproofing Proprietary
Flue Installation. High Efficiency Condensing Boilers
Flue Installation High Efficiency Condensing Boilers Table of contents INTRODUCTION 1 Instruction guidance...4 1.1 Product documentation...4 1.2 Explanation of symbols...4 1.3 Important Notes...4 INSTALLATION
WC flushing cistern single or dual flush 0.13 0.05 2 to fill in 2 minutes WC trough cistern 0.15 per WC 0.10 2 Wash basin tap size 1 2
HAC_C0.qxd 7/4/08 9: Page 74 Chapter Pipe sizing Pipes and fittings should be sized so that the flow rates for individual draw-offs are equal to the design flow rates shown in table.. During simultaneous
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
CUBICLE SYSTEMS LTD. CI/SfB 74 X IPS. Pre-plumbed Wall Duct Access Panel System
CUBICLE SYSTEMS LTD CI/SfB 74 X IPS Pre-plumbed Wall Duct Access Panel System ISO 9001:2000 IPS the perfect washroom solution plumbing wall duct panel system and cubicles installed in one operation Cubicle
Drainage and waste disposal
13 Drainage and waste disposal 13.1 Introduction This chapter describes Part H of Schedule 1 to the Building Regulations 2000 as amended) and the associated Approved Document H. Together, these documents
GENERAL RUBBER LINING PRINCIPLES
GENERAL RUBBER LINING PRINCIPLES I. METAL PREREQUISITES Metal to be lined should meet the requirements as stated in section 8 Metal Fabrication and section 12 Blasting and Cementing Procedures. The surface
BOQ for Plumbing, Sanitary Works
BOQ for Plumbing, Sanitary Works Page 1 of 6 Sr.No Item Description Quantity Unit Rate Amount (Rs.) 1 SANITARY FIXTURES Providing & Fixing star white colour vitreous china wall mounted wc with 1a heavy
Reticulation sewers in basements Technical guidelines
Reticulation sewers in basements Technical guidelines Overview What These guidelines explain our technical requirements for laying sewers in building basements. The scope of the guide is restricted to
Packaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
Installation Guide. Bath and Wall Surrounds SERIES 7104 1021861-2-B
Installation Guide and Wall Surrounds SERIES 7104 1021861-2-B Thank You For Choosing Sterling We appreciate your commitment to Sterling value. Please take a few minutes to review this manual before you
This section gives you some helpful information and tips on running your home and the equipment in it.
67 This section gives you some helpful information and tips on running your home and the equipment in it. Electricity Fuse board (electrical consumer unit) Make sure you know where your fuse board is and
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery
Part 3 Ancillary technologies Chapter CONTENTS SCOPE Clause Page DESIGN Design standards D1 1 Statutory requirements D2 1 System design D3 1 Building integration D4 2 Noise D5 2 Access and controls D6
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
FIX TURE CARRI ERS. 140(a) MPB-2011-USA
FIXTURE CARRIERS STRUCTURAL FEET The feet are heavy duty cast ductile iron and invertible. No distinction is necessary between right and left hand. Each foot wraps around the specially formed edge of the
Technical Information
Technical Information This section of the catalogue provides technical information that will help specify, install and maintain Surelock McGill devices and components. The topics are listed below: Blast
ACO Water Management: Civils + Infrastructure
ACO Water Management: Civils + Infrastructure Uniclass L3 + L735 CI/SfB (5.5) EPIC J343 ACO MultiDrain MD ACO MultiDrain MD channel drainage system Technical Data ACO MultiDrain MD Introduction to the
necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the
Chapter 7 PLUMBING AND ELECTRICAL 7.1 Introduction to Plumbing and Electrical Consideration of support services such as plumbing and electrical systems from the preliminary schematics phase through final
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
CEILING SYSTEMS. CI/SfB (35) Xy April 2006. [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design
CEILING SYSTEMS [Between us, ideas become reality.] CI/SfB (35) Xy April 2006 ULTIMA CANOPY Data sheet Acoustic performance meets High Design ULTIMA CANOPY Installation Instructions I. GENERAL 1. Product
50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance
02/15 Labko GRP cesspools Instructions for installation, operation and maintenance Reliable solutions Wastewater treatment systems Contents 1 LABKO CESSPOOLS... 3 1.1 GENERAL... 3 1.2 IMPORTANT TO KNOW
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow
PLUMBING ROUGH IN INSPECTION
This Program is made Possible through the Code Officials Education & Training Fund. Revenue for the Fund comes from Assessments on Building Permits. Please turn down cell phones and put pagers on vibrate.
Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions
Close Coupled & Back To Wall WC Saintaryware Fitting Instructions Before starting any installation project please consider the following: Prior to drilling into walls, check there are no hidden electrical
building engineering services association specification for: Domestic Heating www.thebesa.com
building engineering services association specification for: Domestic central Heating installation www.thebesa.com building engineering services association acknowledgments Guide to good practice: Domestic
Mechanical Services Standard Specification 5.0 - Compressed Air Systems. May 2010. For ROYAL HOLLOWAY UNIVERSITY OF LONDON
Mechanical Services Standard Specification 5.0 - Compressed Air Systems May 2010 For ROYAL HOLLOWAY UNIVERSITY OF LONDON Prepared For The Estates Division By: Hulley & Kirkwood Consulting Engineers Ltd
T H A N K Y OU F O R Y OUR P U R C H A S E O F A N E S S E N T I A V A N I T Y, P L E A S E R E A D T H E S E V A N I T Y C A R E A N D I N S T A L L
T H A N K Y OU F O R Y OUR P U R C H A S E O F A N E S S E N T I A V A N I T Y, P L E A S E R E A D T H E S E V A N I T Y C A R E A N D I N S T A L L AT I O N I N S T R U C T I O N S C A R E F U L LY CAR
Value Engineering Considerations for Cast Iron Soil Pipe and PVC in Commercial Sanitary and Storm Drainage Applications
Value Engineering Considerations for Cast Iron Soil Pipe and PVC in Commercial Sanitary and Storm Drainage Applications BR-VEC (2-14-13) The Correct Material for the Correct Application Plumbing design
Compliance Document for New Zealand Building Code Clause G13 Foul Water Second Edition
Compliance Document for New Zealand Building Code Clause G13 Foul Water Second Edition Prepared by the Department of Building and Housing This Compliance Document is prepared by the Department of Building
REGISTRATION EXAMINATION, NOVEMBER 2013 CERTIFYING PLUMBER ANSWER SCHEDULE
No. 9195 REGISTRATION EXAMINATION, NOVEMBER 2013 CERTIFYING PLUMBER ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2013. All rights reserved. No part of this publication may be reproduced
What to Expect From the Examination. How to Study the Plumbing Codes
Texas State Board of Plumbing Examiners Plumbing Inspector Examination Review Course The following Examination Review Course is designed to assist an applicant in preparing for the Plumbing Inspector examination.
4 Installation Requirements
4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming
Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW
Installation, Operating and Maintenance Instructions 90/4.5.5 Rev. 0 Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Table of Contents SECTION I... 2 INSTALLATION...
REGISTRATION EXAMINATION, JUNE 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours
Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 99 REGISTRATION EXAMINATION, JUNE 009 PLUMBING INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed THREE
SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION
SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION 1. SCOPE Pipe subsoil drains shall be constructed in accordance with this specification and in conformity with the lines, grades and cross-sections shown
Guidelines for Earthquake Bracing of Residential Water Heaters
Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)
Guernsey Technical Standard
Development & Planning Authority Guernsey Technical Standard Sanitation, Drainage and hot waste water disposal safety & water efficiency The Building (Guernsey) Regulations, 2012 HH1 Foul Water Drainage
Heating and Domestic Hot Water Systems for dwellings Achieving compliance with Part L 2008
Heating and Domestic Hot Water Systems for dwellings Achieving compliance with Part L 2008 Appendix: Guide to the Condensing Boiler Installation Assessment Procedure for Existing Dwellings CONTENTS PAGE
2010 Residential Water Heater Replacement Check List
2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This
SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE
31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE Edited 21/12/01 Wyong Shire Council has many non sewered areas that
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression
40 ltr Domestic Grease Trap GTO1. 200 ltr Commercial Grease Trap GTO2. Rotational Moulders providing State of the Art Product Design and Developement.
Rotational Moulders providing State of the Art Product Design and Developement. The JFC Grease Trap system is designed: GREASE TRAPS A major problem in the drainage systems of dwelling houses, restaurants,
PLUMBING MAINTENANCE WORK FOR TOILETS IN HEAD OFFICE, SUPPLYCO ESTIMATE
Sl.No. PLUMBING MAINTENANCE WORK FOR TOILETS IN HEAD OFFICE, SUPPLYCO ESTIMATE Description of item Qty Unit Rate Amount 1 Demolishing tile work/cement concrete/( carefully taking out the closet and other
HDA -----------------------------------------------------------
----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS
The Worcester Greenstar System Filter. An innovative solution for reducing system contaminants
The Worcester Greenstar System Filter An innovative solution for reducing system contaminants Protect your customer s heating system with the Greenstar System Filter Modern condensing boilers are precision
EFFECTIVE FEBRUARY 2014. note: drainage permit required to call for a dampproof inspection
EFFECTIVE FEBRUARY 2014 note: drainage permit required to call for a dampproof inspection 1. ROOF DRAINS/DECK DRAINS (INTERIOR ) All roof and deck drains within the perimeter of the building shall be APPROVED
DYKA BV P O Box 33 NL-8330 AA Steenwijk Netherlands Tel: 00 31 521 534 917 Fax: 00 31 521 534 989 e-mail: [email protected] website: www.dyka.
CI/SfB (52) DYKA BV P O Box 33 NL-8330 AA Steenwijk Netherlands Tel: 00 31 521 534 917 Fax: 00 31 521 534 989 e-mail: [email protected] website: www.dyka.com Designated by Government to issue European Technical
Colonnade Security Pipe
Description: Round & Square downpipe formed from extruded 6060 T4 aluminium in various sizes (Ø83mm, Ø108mm, 83x83 mm & 108x108mm*) & supplied with a complete range of accessories i.e. Offsets, bends,
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths Operating instructions Universal water baths SUB6: 6 litres SUB14: 14 litres SUB28: 28 litres SUB36: 36 litres Boiling baths SBB6:
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced
Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.
CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,
MAXFLOW SYPHONIC DRAINAGE SYSTEM
Tamakiş Sifonik Yagmur Suyu Toplama Sistemleri Inşaat San.ve Tic Ltd, STI Park Maya Sitesi Maya Meridyen Iş Merkezi No 2 Kat:7 Akatlar Istanbul 34335 Turkey Tel: 00 90 212 352 4600 Fax: 00 90 212 352 3666
GYPSUM AREA SEPARATION FIREWALLS GA-620-2011
GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GA-620-2011 Copyright 2011 Gypsum Association All rights reserved. Printed in U.S.A. Characteristics, properties, or performance of materials or systems herein
SECTION 08000 STORM DRAINAGE TABLE OF CONTENTS
SECTION 08000 STORM DRAINAGE 08010 DESIGN A. Location B. Sizing TABLE OF CONTENTS 08020 MATERIALS A. Pipe Materials B. Structure Materials C. Installation D. Inlets and Outlets 08030 INSPECTIONS AND TESTING
Residential Inspection Guidelines
Residential Inspection Guidelines 201 Pre-Pour Foundation Dimensions Building Location Certificate - if required in the building consent Construction and Advice Notes Check the building dimensions against
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 [email protected]
CARDOK CARLIFT Fast access to underground garages Fast, Silent, Discreet, Design, High-Tech Installation to replace an access ramp on private property Dimensions: (Built to measure, all dimensions can
A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.
PART 1 GENERAL 1.1 SCOPE A. This item shall include the work necessary for the installation of storm sewer line construction. B. Reference Section 3800 Trenching and Backfill and the General Conditions,
WATER LEAKS AND DAMAGE
WATER LEAKS AND DAMAGE OUTLINE A quarter of all insurance claims made on flats are for damage caused by water leaks. The damage caused costs millions of pounds, heartache to those involved and disputes
DRAINAGE SYSTEMS FOR BEVERAGE INDUSTRIES
DRAINAGE SYSTEMS FOR BEVERAGE INDUSTRIES K E E P I N G U P T H E F L O W S T A I N L E S S S T E E L D R A I N A G E S Y S T E M S BREWERIES & DAIRIES BLÜCHER provides drainage solutions for removing
2006 Codes. Please verify the following before calling for inspection
INSPECTION CHECKLIST RESIDENTIAL PLUMBING ROUGH IN 2006 Codes This checklist is intended for use to prepare for an inspection. This is only a general list and is not intended to address all possible conditions.
Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association
Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-
SECTION 02630 STORM DRAINAGE SYSTEM
SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE
SECTION 221413 FACILITY STORM DRAINAGE PIPING
SECTION 221413 FACILITY STORM DRAINAGE PIPING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
CHAPTER 9 VENTS. copper drainage tube Type DWV, Schedule 40 plastic piping, or borosilicate glass.
CHAPTER 9 VENTS 901 GENERAL 901.1 Scope The provisions of this chapter shall govern the materials, design, construction, and installation of vents. 901.2 Protection of Trap Seals The protection of trap
Installation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized
Installation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized Gravity Solar System Installation Manual: This manual explains how to install a system of evacuated
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials
Installation Instructions 4508 4508S
SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect
Timber Decks. Technical Note. March 2007
Timber Decks Technical Note. March 2007 This Technical Note contains general information for residential timber decks and floor frame structures for veranda s, patios etc which are exposed to the weather.
Coolflo Safe Touch Shower Mixing Valve ST20015CP
Coolflo Safe Touch Shower Mixing Valve ST20015CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept
Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
Qualification Guide. BPEC 601/2514/7 - Level 1 Diploma in Plumbing Foundation. BPEC 600/9432/1 - Level 2 Diploma in Plumbing Foundation
Qualification Guide BPEC 601/2514/7 - Level 1 Diploma in Plumbing Foundation BPEC 600/9432/1 - Level 2 Diploma in Plumbing Foundation BPEC 600/5270/3 - Level 2 NVQ Diploma in Plumbing and Heating BPEC
When Should Examination Preparation Begin?
Texas State Board of Plumbing Examiners Tradesman Plumber-Limited Licensee Examination Review Course The following Examination Review Course is designed to assist a registered Plumber s Apprentice in preparing