Servers and two Client with failover
|
|
- Aubrie Garrett
- 8 years ago
- Views:
Transcription
1 How to create two VIO Servers and two Client with failover Author : Siddhartha S Sinha Rev : 1.0 Check my website for more technical stuffs.
2 Test Scenario: Two VIO servers will have these physical resources 4 GB of memory, 2 CPU (uncapped with weight of 128) 20 virtual processors 1 quad port Gigabit Ethernet adapter (Network cable only on port 0) Few SAS adapter with local disks Two VIO Clients will have these physical resources 4 GB of memory 4 CPU Virtual disk will be provided by logical volume created in each VIO Server. I will create one separate Volume Group for this purpose in each VIO Server. VG Name will be clientsrootvg and lvnames will be test1rootlv & test2rootlv In both VIO Server We will load the both VIO servers and two test VIOC LPARs from a NIM Server.
3 Once completed testvio1 will look like this testvio2 will look like this test1lpar will look like this
4 and test2lpar will look like this Now we have the plan so we will build the testvio1 server now. STEPS TO BUILD TESTVIO1 SERVER In the HMC I will click on the + sign beside Systems Management then again I will click on Servers and then ServerName. Next screen will be like this. Now I will expand Configuration > Create Logical Partition > VIO Server
5 I will type my first vio Partition name as testvio1, leave the partition id 2 alone and I will click Next. Next I selected Shared processor. This Server has 48 CPU but I wanted to try Shared CPU stuffs so I decided to use it. And I will click Next now.
6 Here I selected 2 minimum, 4 desired and 6 maximum. Then I selected minimum 20 virtual Processor (1 CPU=10 Virtual CPU), 40 Desired and 60 Maximum. And I checked the uncapped Weight 128.0, little Bit too much. Now I will click next Next screen I will straight select absolute 4GB memory requirement. So my minimum, Desired and Maximum Memory requirement is 4GB. Nothing more or less. I will click on the Next button once I am done.
7 Ok, I will select the Physical I/Os whatever I planned before for this Server. And then I will click on that little Add as required button before I click on next. If I forget to click on Add as required I will have no I/O at all and I will have to come back and do this again. As I did so I will click on Next Button.
8 Now I always like to add more numbers so I will bump Maximum Virtual Adapters to would be sufficient but I am planning to create some more VIOC Lpars to do some more test after this failover test.
9 I just clicked Next button here as I am not going to use any of these Logical Host Ethernet Adapters for my test. Same thing here. I will just click on Next.
10 I will not change anything here as I want Normal Mode as default. Looks good to me. So I will click the Finish Button.
11 Now I am going to activate it.
12 But I want it to boot to SMS Mode for this session so that I can go and configure the Network to load from my NIM Server and I want the console to be opened same time It is activated. So I checked Open a Terminal window or console session and then I will click on Advanced Button. Now it opened another windows and I will select SMS and will click OK.
13 Now it will open the console and I will setup the interface to boot from my NIM Server. In the mean time I will go to my NIM server and stage NIM Images for this Server. This is the screenshot from my NIM Server. So Installation type is mksysb and makesysb name I gave for this Image as VIOS2_2_mksysb. Also I need a spot so I created one and named it as vios_v2_2_spot and I created lpp_source to for this VIO Image as well as all the VIO images we have. I created the lpp_source to cover any missing driver. I will cover all those steps some other time. Also I have a Customization Script which basically copies extra drivers, softwares, my scripts etc to the client. Then two other files, BOSINST_DATA which I named as No_Prompt picks up some stuffs automatically so that I don t have to wait for selecting disks etc And then Customization FB script Install_Drivers actually install all sdd/sddpcm devices based on the AIX version and does lot of other stuffs automatically so that I don t have to be worry about anything missing. Anyway I already came back and started testvio1 server to boot from network and here is the screen shot
14 Now I can see how and why I needed that lpp_source. This VIO 2.2 version does missing some software or drivers required for this MMB ( latest Power7 ) Server and it is loading them now. Now I will go and build testvio2 same way I did testvio1 and load it from NIM Server. Now both of my VIO Servers built. I am going to login as padmin and it will ask me to Change the password. So I will change it.
15 First thing after logging in to both VIO servers I will do is run this command $ license accept Next thing I will do is to create both of my testlpars, test1lpar and test2lpar. I will go to Configuration > Create Logical Partition and will click on AIX or Linux.
16 I will name is as test1lpar and click Next button Profile name I will select as Normal and will click next.
17 I am going to use dedicated Processor for this lpar so I will click on Dedicated and then I will click on Next.
18 I will type 4 for all Minimum, Desired and Maximum processors and then I will click on Next. I will do same thing for Memory and click on next As all the I/Os will be provided by the VIO Servers I will select nothing here and will just Click on Next.
19 I will bump up the nos. of Maximum virtual adapters from 10 to 20 and click on Next I will select nothing here and click on Next.
20 I will select nothing here too and click on Next I won t change anything here and will just click on Next.
21 I will verify CPU and Memory from the screen and will click on Finish Here is my new lpar. I will leave it alone and will build the next one same way.
22 Now all of my lpars built. Now I will select test1vio and change the profile to add the virtual adapters. I will select The lpar and click on Manage Profiles under Configuration menu.
23 Now I will click on Normal. Sometimes for the older servers I had to click on the check Box under Select and then had to go to Actions Button and then Edit button to get into Next screen. I will click on Virtual Adapters Button here.
24 Now I am in Virtual Adapter screen. I will click on Actions button here then Create Virtual Adapter and then Ethernet Adapter
25 Here I will change Virtual Adapter ID to 10, I will leave VLAN ID to 1 I will check the box For This adapter is required for partition activation And I will select checkbox for Access external network and I will leave Trunk priority to 1. I am not selecting IEEE 802.1q compatible adapter for this test. I would select that if I had few CISCO tagged VLANS. After making all the necessary changes I will click OK. I will do again do the same again for next adapter Actions Create Virtual Adapter Ethernet Adapter And this time I will select Adapter ID as 11 and VLAN 99 and nothing else. This will be used as Control Channel Virtual Ethernet.
26 Now I will add the Virtual SCSI Adapters. So Actions Create Virtual Adapter SCSI Adapter Then I will use 20 for Virtual SCSI Adapter. I will click on the check box for This Adapter is Required for partition activation and then I will select Only selected client partition can connect and from the drop down menu I will select test1lpar(4) and then I will type Client Adapter ID 15 and then I will click OK button.
27 Now I will add another Virtual SCSI adapter using the same method. This time I will use Virtual SCSI Adapter ID 21 I will click on the check box on This adapter is required for partition activation and Then I will click on Only selected client partition can connect and from the drop down menu I will select test2lpar(5) and then I will type Client Adapter ID 15 and then I will click OK button. Final screen looks like this. Now I will click OK, and then I will shutdown testvio1 lpar. $shutdown force Once this lpar is down I will re activate it from HMC. Now I will select testvio2 and will do the same thing. For 1st Virtual Ethernet adapter id I will use 12, VLAN ID 1, I will check on This adapter is required for partition activation. I will also select This adapter is Required for partition activation check box. And most important for this box is Trunk Priority will be 2
28 Next adapter ID will be 13, VLAN ID 99 and I will select This adapter is required for partition activation Now I will add the Virtual SCSI Adapters. Final screen will be like this.
29 Now I will shutdown this lpar testvio2 $ shutdown force And then I will activate it from HMC. Now I will log in to testvio1 using padmin id and password I set before and will run this command $ lsdev virtual So I got ent4 and ent5 as virtual Ethernet and vhost0 and vhost1 as virtual scsi adapter Now I will create shared Ethernet adapter using ent4 and ent5. But before that I have to remove existing IP address as I installed this server from NIM Server. To do that I will run rmtcpip all and select y and enter.
30 $ rmtcpip all Parameters to be reset: Hostname yes Nameserver yes Effective immediately yes Routing yes Are you sure? (y/n) Y Now I will create the Shared Ethernet Adapter ( SEA) $ mkvdev sea ent0 vadapter ent4 default ent4 defaultid 1 attr \ ha_mode=auto ctl_chan=ent5 ent6 Available Now I will configure the IP address $ mktcpip hostname testvio1 inetaddr interface en5 start netmask \ gateway Now I will check whether I did it right or not using any of these two commands or using both. $ lstcpip interfaces $ netstat state num I will ping the gateway and check whether my network is working or not before I proceed further. Next thing I am going to do is create a separate Volume Group for test1lpar and test2lpar virtual disks. And I will mirror the rootvg. I can use telnet or ssh session too as I just configure the network. From another telnet/ssh session I will run $ extendvg f rootvg hdisk1 $ mirrorios defer hdisk1 ( you can use oem_setup_env and use mirrorvg as this command is going to call mirrorvg command anyway) Now back to console and I will create a Volume Group to use for test1lpar and test2lpar $ mkvg f vg clientsrootvg hdisk2 hdisk3 Verify what previous command did $ lsvg pv clientsrootvg Now I will create lvs to use as rootdisk for test1lpar1 and test2lpar. $ mklv lv test1lparrootlv clientsrootvg 70g hdisk2 ( Mirroring the lvs here was a bad idea I found later, client lpars were very slow because I used mirror option here) $ lsvg lv clientsrootvg $ mklv lv test2lparrootlv clientsrootvg 70g hdisk3
31 $ lsvg lv clientsrootvg Now I will start start assigning these lvs to the associated vhosts. $ lsdev slots # Slot Description Device(s) U9117.MMB.102DB3F V2 C0 Virtual I/O Slot vsa0 U9117.MMB.102DB3F V2 C10 Virtual I/O Slot ent4 U9117.MMB.102DB3F V2 C20 Virtual I/O Slot vhost0 U9117.MMB.102DB3F V2 C21 Virtual I/O Slot vhost1 Vhost0 is on slot 20 and we will use that for test1lpar and vhost1 is on slot21 and we associated that to test2lpar. Now we will run the following commands $ mkvdev vdev test1lparrootlv vadapter vhost0 dev test1lparroot test1lparroot Available $ mkvdev vdev test2lparrootlv vadapter vhost1 dev test2lparroot test2lparroot Available I will verify what I did on vhost0
32 Now on vhost1 Now I will go back to testvio2 and do the same things there before I start the client lpars. Now I will add the Virtual Adapters to test1lpar1 and test2lpar
33 I will add the Virtual Ethernet and both virtual scsi adapters using the same method I did for VIO Servers. Virtual Ethernet Adapter I did as below For the 1st Virtual SCSI Adapters I did as below which will be connected to testvio1
34 For the 2nd Virtual SCSI Adapters I did as below which will be connected to testvio2 Final setting will look like this.
35 Same thing for test2lpar. Settings below for Ethernet And for 1st Virtual SCSI Adapter connected to testvio1
36 Here is what I did for the 2nd Virtual SCSI Adapter connected to testvio2 Now both of my VIOC Lpars built. I will load them from NIM Server. Now to make things easier for me I used hdisk0 for both test1lpar and test2lpar from testvio1 Server. Later I will mirror them with hdisk1 which comes from testvio2 server. NIM load completed now and I will log in to the console for test1lpar as root and no password. I will check the configuration now # lsdev Cc disk # lscfg vpl hdisk0 # lscfg vpl hdisk1
37 From testvio1 server From testvio2
38 Back to test1vio lpar and I will verify disk sizes Now I will login to test2lpar and will do the same
39 Now back to testvio1 and Now on tesvio2
40 Everything is looking good. Back to test2lpar and will check the disk sizes Next thing I will do I will go back to test1lpar and mirror the rootvg
41 So first I will extend the rootvg to hdisk1 # extendvg f rootvg hdisk1 # mirrorvg S m rootvg hdisk1 ( This command will run in the background and will take a while) Now I will go back to test2lpar and do the same thing. Once mirroring completed in both test1lpar and test2lpar I will change the bootlist # bootlist m normal hdisk0 hdisk1 Now I will run bootlist m normal if both entries doesn t look exactly the same then I willrun bosboot ad /dev/hdisk1 and rerun bootlist m normal Hopefully this time it will be OK. Now I will check the rootvg status on both test1lpar Now on test2lpar
42 I will shutdown viotest1 server now.
43 Will verify from HMC Screen
44 Now we will see if the servers still can ping outside or not.
45 So network failover working, server is also up. Now I will check with lsvg I will check test2lpar now
46 Now lsvg on testvio2 Now, I will reboot both test1lpar and test2lpar to check whether it can survive a reboot when test1vio failed. Now I will check how test1lpar looks like.
47 So hdisk0 is defined and not available any more. And it survived a reboot and network also working. Now test2lpar This lpar also survived a reboot though hdisk0 not available and network also working. So we know now that both of my VIOC lpars will work even when testvio1 failed. Now I will run the same test to check whether these two lpars can survive a reboot when testvio2 fails. But before that I need to bring testvio1 online, resync the mirror and then I will test. So I am activating testvio1 now. Once testvio1 is up I will run cfgmgr on both test1lpar and test2lpar and rerun those commands
48 Looks good, now on test2lpar
49 This one also looks good. Now I will check the mirror status. Needs re sync Same thing on test2lpar
50 I will resync them. hdisk0 may come as removed state. I will use chpv command to fix that and then I will run syncvg rootvg. Test1lpar is synced test2lpar is synced Now I will shutdown testvio2
51 test1lpar rootvg stale status
52 test2lpar lv stale status
53 Network still up Few more status after I rebooted test1lpar Conclusion: So finally I could test the VIO failover successfully.
Using Virtual Switches in PowerVM to Drive Maximum Value of 10 Gb Ethernet
Using Virtual Switches in PowerVM to Drive Maximum Value of 10 Gb Ethernet by Glenn E. Miller Certified IT Specialist Power Systems, AIX and PowerHA IBM Corporation and Kris Speetjens IT Architect Nobius
More informationHow to backup and restore the Virtual I/O Server
How to backup and restore the Virtual I/O Server Table of Contents Backing up the Virtual I/O Server... 1 Backing up to a tape or DVD-RAM...1 Backing up to a remote file system by creating a nim_resources.tar
More informationIntegrated Virtualization Manager ESCALA REFERENCE 86 A1 82FA 01
Integrated Virtualization Manager ESCALA REFERENCE 86 A1 82FA 01 ESCALA Integrated Virtualization Manager Hardware May 2009 BULL CEDOC 357 AVENUE PATTON B.P.20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE
More informationCentralize AIX LPAR and Server Management With NIM
Page 1 of 6 close window Print Centralize AIX LPAR and Server Management With NIM June July 2009 by Jaqui Lynch Available Downloads: Code Sample 1 Code Sample 2 NIM Resources In a previous article, Simplifying
More informationGetting started with IBM i on an IBM Flex System compute node.
F Getting started with IBM i on an IBM Flex System compute node. Mike Schambureck (schambur@us.ibm.com) IBM i Lab Services,Rochester, MN Jan 2013 Getting Started with IBM i on an IBM PureFlex System Compute
More informationStep-by-Step Guide. to configure Open-E DSS V7 Active-Active iscsi Failover on Intel Server Systems R2224GZ4GC4. Software Version: DSS ver. 7.
Step-by-Step Guide to configure on Intel Server Systems R2224GZ4GC4 Software Version: DSS ver. 7.00 up01 Presentation updated: April 2013 www.open-e.com 1 www.open-e.com 2 TECHNICAL SPECIFICATIONS OF THE
More informationSystemverwaltung 2009 AIX / LPAR
Systemverwaltung 2009 AIX / LPAR Course materials may not be reproduced in whole or in part without the prior written permission of IBM. 4.0.1 Integrated Virtualization Manager (IVM) (1 of 2) Provides
More informationVMWare Workstation 11 Installation MICROSOFT WINDOWS SERVER 2008 R2 STANDARD ENTERPRISE ED.
VMWare Workstation 11 Installation MICROSOFT WINDOWS SERVER 2008 R2 STANDARD ENTERPRISE ED. Starting Vmware Workstation Go to the start menu and start the VMware Workstation program. *If you are using
More informationVirtualization Standards for Business Continuity: Part 1
The purpose of this series of articles is to define the policies, guidelines, standards, and procedures that provide the foundation of a virtualized environment enabling business continuity, disaster recovery,
More informationStep-by-Step Guide to Open-E DSS V7 Active-Active iscsi Failover
www.open-e.com 1 Step-by-Step Guide to Software Version: DSS ver. 7.00 up10 Presentation updated: June 2013 www.open-e.com 2 TO SET UP ACTIVE-ACTIVE ISCSI FAILOVER, PERFORM THE FOLLOWING STEPS: 1. Hardware
More informationHyper-V Installation Guide for Snare Server
Hyper-V Installation Guide for Snare Server Intersect Alliance International Pty Ltd. All rights reserved worldwide. Intersect Alliance Pty Ltd shall not be liable for errors contained herein or for direct,
More informationStep-by-Step Guide to Open-E DSS V7 Active-Active Load Balanced iscsi HA Cluster
www.open-e.com 1 Step-by-Step Guide to Open-E DSS V7 Active-Active Load Balanced iscsi HA Cluster (without bonding) Software Version: DSS ver. 7.00 up10 Presentation updated: May 2013 www.open-e.com 2
More informationHow To Run A Power5 On A Powerbook On A Mini Computer (Power5) On A Microsoft Powerbook (Power4) On An Ipa (Power3) On Your Computer Or Ipa On A Minium (Power2
Planning for Virtualization Jaqui Lynch Userblue Jaqui.lynch@mainline.com http://www.circle4.com/papers/ubvirtual.pdf Agenda Partitioning Concepts Virtualization Planning Hints and Tips References 1 Partitioning
More informationVirtualization 101 for Power Systems
Page 1 of 6 close window Virtualization 101 for Power Systems October November 2009 by Jaqui Lynch Print Table 1 Resources Since the introduction of POWER5* technology, virtualization has offered many
More informationEqualizer VLB Beta I. Copyright 2008 Equalizer VLB Beta I 1 Coyote Point Systems Inc.
Equalizer VLB Beta I Please read these instructions completely before you install and configure Equalizer VLB. After installation, see the Help menu for Release Notes and the Installation and Administration
More informationRed Hat Linux 7.2 Installation Guide
Red Hat Linux 7.2 Installation Guide Ryan Spangler spanglerrp22@uww.edu http://ceut.uww.edu April 2002 Department of Business Education/ Computer and Network Administration Copyright Ryan Spangler 2002
More information3.1 Connecting to a Router and Basic Configuration
3.1 Connecting to a Router and Basic Configuration Objective This lab will focus on the ability to connect a PC to a router in order to establish a console session and observe the user interface. A console
More informationBest Practices. AIX Operating System Level Backup and Recovery for an IBM Smart Analytics System
IBM Smart Analytics System Best Practices AIX Operating System Level Backup and Recovery for an IBM Smart Analytics System Garrett Fitzsimons IBM Smart Analytics Systems Best Practices Richard Lubell IBM
More informationThis techno knowledge paper can help you if: You need to setup a WAN connection between a Patton Router and a NetGuardian.
Problem: Patton / 240T WAN Setup Platform: NetGuardian 240T This TKP is a guide to setting up a PPP to T1 WAN connection between a Patton Model 2603 Router and a NetGuardian 240T. The example in this guide
More informationNOC PS manual. Copyright Maxnet 2009 2015 All rights reserved. Page 1/45 NOC-PS Manuel EN version 1.3
NOC PS manual Copyright Maxnet 2009 2015 All rights reserved Page 1/45 Table of contents Installation...3 System requirements...3 Network setup...5 Installation under Vmware Vsphere...8 Installation under
More informationF-SECURE MESSAGING SECURITY GATEWAY
F-SECURE MESSAGING SECURITY GATEWAY DEFAULT SETUP GUIDE This guide describes how to set up and configure the F-Secure Messaging Security Gateway appliance in a basic e-mail server environment. AN EXAMPLE
More informationF-Secure Internet Gatekeeper Virtual Appliance
F-Secure Internet Gatekeeper Virtual Appliance F-Secure Internet Gatekeeper Virtual Appliance TOC 2 Contents Chapter 1: Welcome to F-Secure Internet Gatekeeper Virtual Appliance.3 Chapter 2: Deployment...4
More informationLOCKSS on LINUX. CentOS6 Installation Manual 08/22/2013
LOCKSS on LINUX CentOS6 Installation Manual 08/22/2013 1 Table of Contents Overview... 3 LOCKSS Hardware... 5 Installation Checklist... 6 BIOS Settings... 9 Installation... 10 Firewall Configuration...
More informationReboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive
Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive This guide explains how to create and use a Rescue USB flash drive to reinstall and recover the ExtraHop system. When booting
More informationHOWTO: Set up a Vyatta device with ThreatSTOP in router mode
HOWTO: Set up a Vyatta device with ThreatSTOP in router mode Overview This document explains how to set up a minimal Vyatta device in a routed configuration and then how to apply ThreatSTOP to it. It is
More informationCreate a virtual machine at your assigned virtual server. Use the following specs
CIS Networking Installing Ubuntu Server on Windows hyper-v Much of this information was stolen from http://www.isummation.com/blog/installing-ubuntu-server-1104-64bit-on-hyper-v/ Create a virtual machine
More informationAP6511 First Time Configuration Procedure
AP6511 First Time Configuration Procedure Recommended Minimum Configuration Steps From the factory, all of the 6511 AP s should be configured with a shadow IP that starts with 169.254.xxx.xxx with the
More informationMAX T1/E1. Quick Start Guide. VoIP Gateway. Version 1.0
MAX T1/E1 TM VoIP Gateway Quick Start Guide Version 1.0 Contents INTRODUCTION 1 Hardware Needed Software Needed 1 1 NET2PHONE MAX SET UP Hardware Set Up Software Set Up Set Up Internet Protocol (IP) Address
More informationExinda How to Guide: Virtual Appliance. Exinda ExOS Version 6.3 2012 Exinda, Inc
Exinda How to Guide: Virtual Appliance Exinda ExOS Version 6.3 2 Virtual Appliance Table of Contents Part I Introduction 4 1 Using... this Guide 4 Part II Overview 6 Part III Deployment Options 8 Part
More informationALOHA Load Balancer Quickstart guide
ALOHA Load Balancer Quickstart guide Summary 1 Package contents... 3 2 Preparing your Aloha... 4 3 Cabling... 5 3.1 Howto... 5 3.2 ALBBOX Overview... 6 3.3 ALB2K Overview... 7 3.4 ALB4K, ALB8K and ALB16K
More informationNote: This case study utilizes Packet Tracer. Please see the Chapter 5 Packet Tracer file located in Supplemental Materials.
Note: This case study utilizes Packet Tracer. Please see the Chapter 5 Packet Tracer file located in Supplemental Materials. CHAPTER 5 OBJECTIVES Configure a router with an initial configuration. Use the
More informationIf you re not using Citrix XenCenter 6.0, your screens may vary. Required Virtual Interface Maps to... mgmt0. virtual network = mgmt0 wan0
If you re not using Citrix XenCenter 6.0, your screens may vary. VXOA VIRTUAL APPLIANCES Citrix XenServer Hypervisor In-Line Deployment (Bridge Mode) 2012 Silver Peak Systems, Inc. Support Limitations
More informationVirtual Appliance Setup Guide
The Virtual Appliance includes the same powerful technology and simple Web based user interface found on the Barracuda Web Application Firewall hardware appliance. It is designed for easy deployment on
More informationEXPRESSCLUSTER X for Windows Quick Start Guide for Microsoft SQL Server 2014. Version 1
EXPRESSCLUSTER X for Windows Quick Start Guide for Microsoft SQL Server 2014 Version 1 NEC EXPRESSCLUSTER X 3.x for Windows SQL Server 2014 Quick Start Guide Document Number ECX-MSSQL2014-QSG, Version
More informationSysPatrol - Server Security Monitor
SysPatrol Server Security Monitor User Manual Version 2.2 Sep 2013 www.flexense.com www.syspatrol.com 1 Product Overview SysPatrol is a server security monitoring solution allowing one to monitor one or
More informationSetup Cisco Call Manager on VMware
created by: Rainer Bemsel Version 1.0 Dated: July/09/2011 The purpose of this document is to provide the necessary steps to setup a Cisco Call Manager to run on VMware. I ve been researching for a while
More informationInstall Guide for JunosV Wireless LAN Controller
The next-generation Juniper Networks JunosV Wireless LAN Controller is a virtual controller using a cloud-based architecture with physical access points. The current functionality of a physical controller
More informationLOCKSS on LINUX. Installation Manual and the OpenBSD Transition 02/17/2011
LOCKSS on LINUX Installation Manual and the OpenBSD Transition 02/17/2011 1 Table of Contents Overview... 3 LOCKSS Hardware... 5 Installation Checklist... 7 BIOS Settings... 10 Installation... 11 Firewall
More informationIntroduction to AIX 6L System Administration Course Summary
Contact Us: (616) 875-4060 Introduction to AIX 6L System Administration Course Summary Length: 5 days Recommendation Statement: Basic computer skills Course Description: This course teaches introductory
More informationIntroduction to Operating Systems
Introduction to Operating Systems It is important that you familiarize yourself with Windows and Linux in preparation for this course. The exercises in this book assume a basic knowledge of both of these
More informationUsing the IPMI interface
Using the IPMI interface The T800, T1600 and T3200 server models are equipped with an IPMI interface with KVM / IP functionality. This enables you to access the server console if it becomes inaccessible
More informationSet Up Panorama. Palo Alto Networks. Panorama Administrator s Guide Version 6.0. Copyright 2007-2015 Palo Alto Networks
Set Up Panorama Palo Alto Networks Panorama Administrator s Guide Version 6.0 Contact Information Corporate Headquarters: Palo Alto Networks 4401 Great America Parkway Santa Clara, CA 95054 www.paloaltonetworks.com/company/contact-us
More informationQuick Start Guide. Citrix XenServer Hypervisor. Server Mode (Single-Interface Deployment) Before You Begin SUMMARY OF TASKS
Quick Start Guide VX VIRTUAL APPLIANCES If you re not using Citrix XenCenter 6.0, your screens may vary. Citrix XenServer Hypervisor Server Mode (Single-Interface Deployment) 2013 Silver Peak Systems,
More informationDeploying Windows Streaming Media Servers NLB Cluster and metasan
Deploying Windows Streaming Media Servers NLB Cluster and metasan Introduction...................................................... 2 Objectives.......................................................
More informationInstallation of the On Site Server (OSS)
Installation of the On Site Server (OSS) rev 1.1 Step #1 - Initial Connection to the OSS Having plugged in power and an ethernet cable in the eth0 interface (see diagram below) you can connect to the unit
More informationDeployment Guide: Transparent Mode
Deployment Guide: Transparent Mode March 15, 2007 Deployment and Task Overview Description Follow the tasks in this guide to deploy the appliance as a transparent-firewall device on your network. This
More informationDisaster Recovery Cookbook Guide Using VMWARE VI3, StoreVault and Sun. (Or how to do Disaster Recovery / Site Replication for under $50,000)
Disaster Recovery Cookbook Guide Using VMWARE VI3, StoreVault and Sun. (Or how to do Disaster Recovery / Site Replication for under $50,000) By Scott Sherman, VCP, NACE, RHCT Systems Engineer Integrated
More informationGuide to Installing BBL Crystal MIND on Windows 7
Guide to Installing BBL Crystal MIND on Windows 7 Introduction The BBL Crystal MIND software can not be directly installed on the Microsoft Windows 7 platform, however it can be installed and run via XP
More informationBuilding a Penetration Testing Virtual Computer Laboratory
Building a Penetration Testing Virtual Computer Laboratory User Guide 1 A. Table of Contents Collaborative Virtual Computer Laboratory A. Table of Contents... 2 B. Introduction... 3 C. Configure Host Network
More informationBasic ESXi Networking
Basic ESXi Networking About vmnics, vswitches, management and virtual machine networks In the vsphere client you can see the network diagram for your ESXi host by clicking Networking on the Configuration
More informationCreating Custom Nameservers Contents
Creating Custom Nameservers Contents Goals... 2 Register Name Servers... 2 Setup Private NameServers in WHM... 4 Adding IP addresses for your name server... 5 Conclusion... 5 Goals This guide will help
More informationHOWTO: Set up a Vyatta device with ThreatSTOP in bridge mode
HOWTO: Set up a Vyatta device with ThreatSTOP in bridge mode Overview This document explains how to set up a minimal Vyatta device in a transparent bridge configuration and then how to apply ThreatSTOP
More informationHow To Set Up A Two Node Hyperv Cluster With Failover Clustering And Cluster Shared Volume (Csv) Enabled
Getting Started with Hyper-V and the Scale Computing Cluster Scale Computing 5225 Exploration Drive Indianapolis, IN, 46241 Contents Contents CHAPTER 1 Introduction to Hyper-V: BEFORE YOU START. vii Revision
More informationGX-V. Quick Start Guide. Microsoft Hyper-V Hypervisor. Before You Begin SUMMARY OF TASKS. Before You Begin WORKSHEET VIRTUAL GMS SERVER
Quick Start Guide GX-V VIRTUAL GMS SERVER Microsoft Hyper-V Hypervisor 2012 Silver Peak Systems, Inc. Before You Begin Windows 2008 server installed and Hyper-V is running Hyper-V management software is
More informationLinux. Installing Linux on Power Systems servers
Linux Installing Linux on Power Systems servers Linux Installing Linux on Power Systems servers Note Before using this information and the product it supports, read the information in Notices on page
More informationVELOCITY. Quick Start Guide. Citrix XenServer Hypervisor. Server Mode (Single-Interface Deployment) Before You Begin SUMMARY OF TASKS
If you re not using Citrix XenCenter 6.0, your screens may vary. VELOCITY REPLICATION ACCELERATOR Citrix XenServer Hypervisor Server Mode (Single-Interface Deployment) 2013 Silver Peak Systems, Inc. This
More informationF-Secure Messaging Security Gateway. Deployment Guide
F-Secure Messaging Security Gateway Deployment Guide TOC F-Secure Messaging Security Gateway Contents Chapter 1: Deploying F-Secure Messaging Security Gateway...3 1.1 The typical product deployment model...4
More informationDebugging Network Communications. 1 Check the Network Cabling
Debugging Network Communications Situation: you have a computer and your NetBurner device on a network, but you cannot communicate between the two. This application note provides a set of debugging steps
More informationiseries Logical Partitioning
iseries Logical Partitioning Logical Partition (LPAR) SYS1 1:00 Japan SYS2 10:00 USA SYS3 11:00 Brazil SYS4 15:00 UK ORD EMEPROGRESSO i5/os Linux i5/os AIX LPARs operate independently! iseries Partition
More informationCloud Infrastructure Management - IBM VMControl
Cloud Infrastructure Management - IBM VMControl IBM Systems Director 6.3 VMControl 2.4 Thierry Huche IBM France - Montpellier thierry.huche@fr.ibm.com 2010 IBM Corporation Topics IBM Systems Director /
More informationThe RT module VT6000 (VT6050 / VT6010) can be used to enhance the RT. performance of CANoe by distributing the real-time part of CANoe to a
Getting started with VT6000 and VT6104 The RT module VT6000 (VT6050 / VT6010) can be used to enhance the RT performance of CANoe by distributing the real-time part of CANoe to a dedicated RT execution
More informationUsing iscsi with BackupAssist. User Guide
User Guide Contents 1. Introduction... 2 Documentation... 2 Terminology... 2 Advantages of iscsi... 2 Supported environments... 2 2. Overview... 3 About iscsi... 3 iscsi best practices with BackupAssist...
More informationManagement Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.
Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of
More informationSmartFiler Backup Appliance User Guide 2.0
SmartFiler Backup Appliance User Guide 2.0 SmartFiler Backup Appliance User Guide 1 Table of Contents Overview... 5 Solution Overview... 5 SmartFiler Backup Appliance Overview... 5 Getting Started... 7
More informationTrend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice.
Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice. Before installing and using the software, please review the readme files,
More informationQuick Installation Guide Network Management Card
Rev.1.1 www.cyberpowersystems.com Quick Installation Guide Network Management Card Intelligent Network Management Card allows UPS to be managed, monitored, and configured via SNMP Card Configuration Tool
More informationSANtricity Storage Manager 11.25
SANtricity Storage Manager 11.25 Software Installation Reference NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888)
More informationConfiguring the Switch with the CLI Setup Program
APPENDIXC Configuring the Switch with the CLI Setup Program This appendix provides a command-line interface (CLI) setup procedure for a standalone switch. To set up the switch by using Express Setup, see
More informationShifting Gears: VMControl to PowerVC
ATS Experts Exchange November 2013 Shifting Gears: VMControl to PowerVC Glen Corneau, Agenda A review of VMControl Express, Standard and Enterprise Editions Image repositories System Pools PowerVC Based
More informationAdministering the Network Analysis Module. Cisco IOS Software. Logging In to the NAM with Cisco IOS Software CHAPTER
CHAPTER 4 How you administer the NAM on your Catalyst 6500 series switch or Cisco 7600 series router depends on whether you are using the Cisco IOS software or the Catalyst operating system software. Several
More informationeduc Office 365 email: Remove & create new Outlook profile
Published: 29/01/2015 If you have previously used Outlook the with the SCC/SWO service then once you have been moved into Office 365 your Outlook will need to contact the SCC/SWO servers one last time
More informationOptimum Business SIP Trunk Set-up Guide
Optimum Business SIP Trunk Set-up Guide For use with IP PBX only. SIPSetup 07.13 FOR USE WITH IP PBX ONLY Important: If your PBX is configured to use a PRI connection, do not use this guide. If you need
More informationOutlook Connector Installation & Configuration groupwaresolution.net Hosted MS Exchange Alternative On Linux
Outlook Connector Installation & Configuration groupwaresolution.net Hosted MS Exchange Alternative On Linux Page 1 of 5 DOWNLOAD Please download the connector installer msi file and save it to your computer.
More informationIP Phone Configuration and Troubleshooting Guide
IP Phone Configuration and Troubleshooting Guide NetVanta 7000 Series and IP 700 Series Phones Overview The purpose of this guide: Explain the default configuration. Explain how to configure the NetVanta
More informationClassroom Management network FAQ and troubleshooting
Classroom Management network FAQ and troubleshooting Author: Grant Kelly The concepts in this document are intended to be a guide to aid in the resolution of certain issues that occur with using the Classroom
More informationJob Aid: Replacing the Hard Drive on the Avaya S8710 Media Servers R2.2 or Later
Job Aid: Replacing the Hard Drive on the Avaya S8710 Media Servers R2.2 or Later This job aid describes the steps required to replace the hard drive on an Avaya S8710 Media Servers running Release 2.2
More informationGuide to the LBaaS plugin ver. 1.0.2 for Fuel
Guide to the LBaaS plugin ver. 1.0.2 for Fuel Load Balancing plugin for Fuel LBaaS (Load Balancing as a Service) is currently an advanced service of Neutron that provides load balancing for Neutron multi
More informationGeneral Tips: Page 1 of 20. By Khaled Elshaer. www.bimcentre.com
Page 1 of 20 This article shows in details how to install Primavera P6 on SQL server 2012. The same concept should apply to any other versions. Installation is divided into 3 Sections. A. Installing SQL
More informationSETTING UP REMOTE ACCESS ON EYEMAX PC BASED DVR.
SETTING UP REMOTE ACCESS ON EYEMAX PC BASED DVR. 1. Setting up your network to allow incoming connections on ports used by Eyemax system. Default ports used by Eyemax system are: range of ports 9091~9115
More informationCisco - Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW)
Page 1 of 20 Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW) Document ID: 50036 Contents Introduction Prerequisites Requirements Components Used Network Diagram The Role of Switched
More informationStarWind iscsi SAN Software Hands- On Review
StarWind iscsi SAN Software Hands- On Review Luca Dell'Oca April 2011 I ve always been fascinated by those software that let you transform a computer into a SAN appliance. The available uses of this kind
More informationRequired Virtual Interface Maps to... mgmt0. virtual network = mgmt0 wan0. virtual network = wan0 mgmt1. network adapter not connected lan0
VXOA VIRTUAL APPLIANCES Microsoft Hyper-V Hypervisor Router Mode (Out-of-Path Deployment) 2013 Silver Peak Systems, Inc. Assumptions Windows 2008 server is installed and Hyper-V server is running. This
More informationQLogic 10GbE 3GCNA Lab
QLogic 10GbE 3GCNA Lab Lab Overview Designed to provide an overview of the QLogic 8200 Series converged Network Adapter (CNA), this guide outlines the setup, installation, configuration and instructions
More informationUltra Thin Client TC-401 TC-402. Users s Guide
Ultra Thin Client TC-401 TC-402 Users s Guide CONTENT 1. OVERVIEW... 3 1.1 HARDWARE SPECIFICATION... 3 1.2 SOFTWARE OVERVIEW... 4 1.3 HARDWARE OVERVIEW...5 1.4 NETWORK CONNECTION... 7 2. INSTALLING THE
More informationScanShell.Net Install Guide
ScanShell.Net Install Guide Please install the software first - DO NOT PLUG IN THE SCANNER The scanner has been carefully packaged to avoid damage during transportation. Before operating the scanner, please
More informationAmahi Instruction Manual
History of Amahi Chapter 1 Installing fedora 12 and Amahi Home Digital Assistant (HDA) Chapter 2 Your DHCP/DNS options Chapter 3 Network Troubleshooting Chapter 4 Getting Started Appendix: Advanced Hard
More informationCautions When Using BitLocker Drive Encryption on PRIMERGY
Cautions When Using BitLocker Drive Encryption on PRIMERGY July 2008 Fujitsu Limited Table of Contents Preface...3 1 Recovery mode...4 2 Changes in hardware configurations...5 3 Prior to hardware maintenance
More informationEnterprise Remote Control 5.6 Manual
Enterprise Remote Control 5.6 Manual Solutions for Network Administrators Copyright 2015, IntelliAdmin, LLC Revision 3/26/2015 http://www.intelliadmin.com Page 1 Table of Contents What is Enterprise Remote
More informationefolder BDR for Veeam Cloud Connection Guide
efolder BDR for Veeam Cloud Connection Guide Setup Connect Preload Data uh6 efolder BDR Guide for Veeam Page 1 of 36 INTRODUCTION Thank you for choosing the efolder Cloud for Veeam. Using the efolder Cloud
More informationHOMEROOM SERVER INSTALLATION & NETWORK CONFIGURATION GUIDE
HOMEROOM SERVER INSTALLATION & NETWORK CONFIGURATION GUIDE Level 1, 61 Davey St Hobart, TAS 7000 T (03) 6165 1555 www.getbusi.com Table of Contents ABOUT THIS MANUAL! 1 SYSTEM REQUIREMENTS! 2 Hardware
More informationInstallation Guide for WebSphere Application Server (WAS) and its Fix Packs on AIX V5.3L
Installation Guide for WebSphere Application Server (WAS) and its Fix Packs on AIX V5.3L Introduction: This guide is written to help any person with little knowledge in AIX V5.3L to prepare the P Server
More informationIntelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)
Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2) Hyper-V Manager Hyper-V Server R1, R2 Intelligent Power Protector Main
More informationAhsay Replication Server v5.5. Administrator s Guide. Ahsay TM Online Backup - Development Department
Ahsay Replication Server v5.5 Administrator s Guide Ahsay TM Online Backup - Development Department October 9, 2009 Copyright Notice Ahsay Systems Corporation Limited 2008. All rights reserved. Author:
More informationNetwork Detector Setup and Configuration
339 N. Bernardo Avenue, Suite 200 Mountain View, CA 94043 www.airtightnetworks.net MODE SYST RPS MASTR STAT SPEDUPLX STACK 1 2 3 4 5 6 7 8 91 0 11 12 1X 2X 11X 12X 13 14 15 16 1718 19 20 2122 23 24 13X
More informationHardware Information Managing your server, adapters, and devices ESCALA POWER5 REFERENCE 86 A1 00EW 00
86 A1 00EW 00 86 A1 00EW 00 Table of Contents Managing your server, adapters, and devices...1 Managing your server using the Hardware Management Console...1 What's new...1 Printable PDFs...2 HMC concepts
More informationDell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com
CHAPTER: Introduction Microsoft virtual architecture: Hyper-V 6.0 Manager Hyper-V Server (R1 & R2) Hyper-V Manager Hyper-V Server R1, Dell UPS Local Node Manager R2 Main Operating System: 2008Enterprise
More informationPlexxi Control Installation Guide Release 2.1.0
Plexxi Control Installation Guide Release 2.1.0 702-20002-10 Rev 1.2 February 19, 2015 100 Innovative Way - Suite 3322 Nashua, NH 03062 Tel. +1.888.630.PLEX (7539) www.plexxi.com Notices The information
More informationMobility System Software Quick Start Guide
Mobility System Software Quick Start Guide Version 8.0 P/N 530-041387 Rev.05 Table of Contents About this Guide Using the Web Quick Start (WLC2, WLC8, WLC200,WLC800R, and WLC880R) Remotely Configuring
More informationIBM AIX 7 Administration
IBM AIX 7 Administration Number: 000-221 Passing Score: 800 Time Limit: 120 min File Version: 1.0 http://www.gratisexam.com/ IBM EXAM 000-221 AIX 7 Administration Exam A QUESTION 1 The following information
More informationEnterprise Erase LAN
Enterprise Erase LAN Network Erasing and Asset Management Server Version 2.0 Users Guide 888.700.8560 toll free www.tabernus.com 11130 Jollyville Rd Suite 301 Austin, TX 78757 Table of Contents 1 Product
More information