Commercial Plumbing Engineer Quick-reference Guide
|
|
|
- Bonnie Jacobs
- 10 years ago
- Views:
Transcription
1 PLUMING SYSTEMS ND REFERENE GUIDE Uponor quapex with PEX-a Pipe Support ommercial Plumbing Engineer Quick-reference Guide This quick reference guide is designed for architects, building officials, engineers and mechanical contractors interested in Uponor ommercial Plumbing Systems. It describes general installation recommendations that use Uponor quapex crosslinked polyethylene (PEX-a) pipe and ProPEX fitting products. Uponor is not liable for installation practices that deviate from this guide or are not acceptable practices within the mechanical trades, codes or standards of practice. lways refer to local codes for additional requirements. For further assistance, refer to the Uponor Plumbing Design ssistance Manual (PDM) or contact Uponor Technical Services at or Uponor quapex (PEX-a) Pipe The ore of Uponor Plumbing Systems Hydrostatic Temperature and Pressure Ratings Uponor maintains standard-grade ratings for Uponor quapex pipe as tested in accordance with PPI TR-. Uponor PEX products have the following temperature and pressure ratings: 00 F (9 ) at 80 psi (55 kpa) 80 F (8 ) at 00 psi (689 kpa) 7.4 F ( ) at 60 psi (,0 kpa) Excessive Short-term Temperature - Pressure apacity: 0 F (99 ) at 50 psi (,04 kpa) tested up to 70 hrs (STM F876) and 48 hr (S 7.5) In accordance with Section 6.6 of STM F876, the minimum hydrostatic burst pressure for " pipe is 480 psi (,09 kpa) at 7.4 F ( ). For 4" pipe and larger, the minimum burst pressure is 475 psi (,75 kpa) at 7.4 F ( ). Uponor s NSF-approved quality lab performs daily burst pressure testing on all pipe sizes above and beyond the STM F876 standard. ll samples are tested at 7.4 F ( ) and burst at an elevated pressure of 800 psi (+/- 0 psi) nearly twice the pressure requirement of STM F876. Not ll PEX is reated Equal Uponor PEX-a Highest degree of crosslinking (>80%) Highest modulus of elasticity Hot" crosslinking above the crystal melting temperature Shape memory ideal for cold-expansion ProPEX fittings Increased resistance to corrosion Most flexible; allows kink reparability; easily bendable against the coil; tight bend radius 6x O.D. PEX-b Lowest degree of crosslinking (>65%) ross linking performed in a secondary, post-extrusion process Stiffer product and no kink reparability PEX-c Lesser degree of crosslinking (>70%) old" crosslinking below the crystal melting temperature Less uniform, less consistent Stiffer, no kink reparability
2 ProPEX Fittings vs. Standard Insert Fittings Wall thickness Flow path " Internal diameter Uponor ProPEX old Expansion Fitting Standard Insert Fitting STM F960 rass STM F960 EP STM F807 rass STM F59 Plastic " 0.057" 0.057" 0.08" 0.056" 4" 0.057" 0.057" 0.07" 0.08" " 0.07" 0.07" 0.04" 0.00" 4" " 0. sq. inches.8 8 ft./sec. 4. ft./sec sq. inches ft./sec. 0.4 ft./sec sq. inches.4 8 ft./sec. 8.6 ft./sec. 0.6 sq. inches.9 8 ft./sec. 4.4 ft./sec. 0.7 sq. inches ft./sec. 0. ft./sec sq. inches. 8 ft./sec. 8. ft./sec sq. inches.4 8 ft./sec..6 ft./sec. 0. sq. inches ft./sec. 8. ft.sec sq. inches ft./sec. 4.8 ft./sec. " 0.78" 0.85" 0.50" 0.5" 4" 0.595" 0.590" 0.50" 0.460" " 0.795" 0.788" 0.70" 0.60" sq. inches.9 8 ft./sec..9 ft./sec sq. inches 4. 8 ft./sec. 6. ft./sec. 0.9 sq. inches 7. 8 ft./sec. 0.9 ft./sec. - Wall thickness - Flow path Double and 70% the wall thickness greater flow - Internal When comparing " F960 with F807 brass fittings diameter When comparing " F960 engineered polymer (EP) with F59 plastic fittings x ÿ.98 REF. S , UNLESS ED URR.00. /".5 REF..0 ±.0 SETION - 6 ProPEX F960 Expansion Fitting oncrete Floor/eiling 8 ssembly 7 6 (UL ITS 5Design No. 4 UW/F 0-0/0) Steel-stud x R.0 Wall ssembly (UL ITS Design No..60 UW/W REF. 60-0) x P050-6x 0? Non-rated wall D or non-load bearing wall /" assembly with Uponor quapex pipe installed per N/UL S0 (refer to UL x R.050 Design No. UW/W 60-0) For N/UL S0 steel-stud rated walls maximum Uponor quapex pipe of. lbs./ft. and not to exceed total weight per stud 6x 0? cavity of 8.0 lbs. Uponor quapex pipe riser Steel stud 5.0 REF. opper manifold or Uponor EP multi-port tee with a weight not exceeding NOTES: REVISIONS.0 lbs. per cavity LETTER EO (typical) # DTE F PV05 0//04 MH./ MOLDED Uponor PEX one G or five-loop PV080 0//04 DRILLED H PV044 06/8/04 OTHER MTERIL stand-up bracket I PV0505 or 0//04 metal/x4 RSS wood 6 pre-drilled 5 mounting 4 bracket on top side of slab 6½" minimum restrained or un-restrained Structural rebar (two layers) 4 UNLESS OTHERWISE SPEIFIED DIMENSIONS RE IN INHES R SETION - TOLERNES RE:. RDIUS LL ORNERS , UNLESS.X OTHERWISE ±.06 SPEIFIED.XX ±.0 D WV008. REGRIND NOT LLOWED 05/9/0.XXX ±.005 NGLES ±? E PV00 8 //0 SURFE FINISH 7 UNLESS OTHERWISE SPEIFIED: x.00 ±.00. REF. D GENERTED DRWING, DO NOT MNULLY UPDTE DO NOT SLE DRWING THE INFORMTION ONTINED IN THIS DRWING IS THE SOLE PROPERTY OF UPONOR WIRSO. NY REPRODUTION IN PRT OR 6WHOLE WITHOUT THE WRITTEN PERMISSION OF UPONOR WIRSO IS PROHIITED. PPROVLS DTE DRWN Y LLZ 0//04 PPROVED Y KL 0//04 I ÿ.60 "Supplier ID" SETION - Markings Detail MRKING ORD TEXT EXTEND.008 REF..68 REF. K SIDE MRKINGS DETIL REVISIONS REF. LETTER EO # DTE NO DETIL PRINT PV /0/05 OTH SIDES MRKINGS PV078 09/06/06 WIRSO OMPNY TH STREET WEST PPLE VLLEY, MN 554 PHONE (95) FX (95) "Date ode".4 REF. UDEL 000 K97 Q&E/ProPEX rass Tee, /" PEX x /" PEX x /" PEX SIZE PRT NO. REV. Q I SLE D FILE: - Q SHEET OF D UNLESS OTHERWISE SPEIFIED DIMENSIONS RE IN INHES TOLERNES RE:.X ±.06.XX ±.0.XXX ±.005 NGLES ±? SURFE FINISH UNLESS OTHERWISE SPEIFIED: MH./ MOLDED 5 DRILLED OTHER MTERIL "ountry of Origin" F807/F59 Insert Fitting ÿ.485 ±.00 D GENERTED DRWING, DO NOT MNULLY UPDTE DO NOT SLE DRWING THE INFORMTION ONTINED IN THIS DRWING IS THE SOLE PROPERTY OF UPONOR WIRSO. NY REPRODUTION IN PRT OR WHOLE WITHOUT THE WRITTEN PERMISSION OF UPONOR WIRSO IS PROHIITED. PPROVLS DTE DRWN Y LP 07//05 PPROVED Y LDH 09//06. REF x.04 WIRSO OMPNY TH STREET WEST PPLE VLLEY, MN 554 PHONE (95) FX (95) SS EP TEE, /" PEX x /" PEX x /" PEX SIZE PRT NO. P SLE - D FILE: P Fire-resistant onstruction Ratings D onstruction Type Non-combustible oncrete/steel onstruction Wood Frame onstruction SHEET REV. OF N/UL S0 ssembly ITS Design No. Type UW/F 0-0/0 Floor/eiling G54 Walls UW/W 60-0 Floor/eiling UW/F 60-0 Walls UW/W 60-0 Mid-story guide (if required) (see riser detail on page 5) Riser clamp (see riser detail on page 5) Firestop listed to N/UL S0 (must be Uponor quapex pipe compatible) N/UL S0 slab listed with Uponor quapex pipe only (refer to UL ITS Design No. UW/F 0-0/0) Maximum tubing density is cubic inches with or without sleeve per one cubic foot of concrete (equivalent of " average spacing through slab between ½" Uponor quapex pipe) Polyethylene sleeve ¾" to " nominal tubing or PV conduit " to ¼" nominal and ½" to " Uponor quapex pipe
3 Minimum Distance etween ProPEX Fittings Nominal Fitting Size ut Length of Pipe " " 4" " " 4 " 4" 5 " " 6 " " 7 " Uponor quapex System odes and Standards STM, NSF, WW, UL, UL, I, IPMO, NH, PH, PPI, HUD, N, NP, S S 7.5 for PEX piping systems STM F876 for PEX pipe STM F876 for continuous hot water recirculation up to 40 F (60 ) Uponor quapex White listed to 506 for 00% recirculation at 40 F (60 ) and one () month UV resistance Uponor quapex Red and lue listed to 506 for 00% recirculation at 40 F (60 ) and three () months UV resistance STM F877 for PEX hot and cold water distribution systems STM F960 for cold expansion fittings for use with PEX pipe STM F0 for oxidative resistance to hot chlorinated water STM F657 for UV resistance of PEX material WW 904 for water service NSF 4 and 6 N/UL S0. for plenum applications up to " N/UL S5 for through-penetration fire stop up to " Pressure Loss (psi) per 00 Feet of Uponor quapex Pipe at 60 F/5.6º Pipe Sizing an Uponor quapex System Uponor recommends using the uniform friction loss method of pipe sizing. fter determining the system s friction loss (psi/00 ft.) by performing a building supply water calculation, develop a water size chart for each system s water temperature. Do this by referencing Uponor quapex flow charts and converting the gallons per minute (gpm) to fixture units for each nominal pipe size. Velocity ft./second " PEX Tubing Velocity ft./second Velocity 4 ft./second Velocity 5 ft./second Velocity ft./second Velocity ft./second Velocity 0 ft./second Velocity 9 ft./second Velocity 8 ft./second Velocity 7 ft./second Velocity 6 ft./second Note: The National Plumbing ode (NP) Section..6...() states the maximum velocities permitted in accordance with the manufacturers recommendations for the pipe and fittings chosen for the installation. Uponor recommends ft./sec. maximum velocity for hot and cold domestic water systems using Uponor quapex pipe and ProPEX fittings. ontact Uponor Technical Services at or [email protected] to determine the maximum velocities based on the use, geographical region and intended operating conditions for your project. 0. " PEX Tubing / " PEX Tubing / 4 " PEX Tubing " PEX Tubing / 4 " PEX Tubing / " PEX Tubing.0 / 8 " PEX Tubing Pressure Loss Flow Rate (gpm).0 0.
4 Suspended Piping For suspended runs of piping, Uponor quapex can be supported by the same conventional means as metallic pipe using copper tube size (TS) pipe hangers or supports. Uponor recommends using hangers and supports designed for use with plastic pipe. Use PEX-a pipe support channel that continuously supports the pipe to achieve the same support spacing as copper pipe. Per NP Table..4.5., the maximum horizontal support spacing for PEX is " (0.8m). If running pipe in a horizontal assembly requiring fire-resistant construction, pipe must be continuously supported or support spacing must not exceed 6" (0.4m) for " and smaller PEX and 4" (0.6m) for 4" and larger runs of PEX. Use of support channel or PEX-a pipe support in conjunction with TS hangers is an alternative to the " (0.8m) on-center support spacing requirements. Support channels allow for greater spacing between hangers; 5' to 8' (.5m to.4m) on-center spacing is achievable if the support channel is installed per the manufacturer s instructions. For more information regarding support solutions, contact Uponor Technical Services at or [email protected]. 8' (.4m) On-enter Suspended levis Support Strapping (optional) U-shapped support channel [available in 9' (.74m) lengths] 8' (.4m) On-enter Trapeze Support Strapping (optional) " (0.8m) On-enter Trapeze Support Steel joist eam clamp Threaded rod (size per load requirements) Standard TS U-shaped clevis hanger spaced at max. 8' (.4m) o.c. [allows for 6" (0.5m) overlap at each channel end] Steel joist eam clamp ll-threaded rod Rubber-lined strut clamp Uponor quapex pipe Steel support channel Steel strut or other hanging device Floor truss Wood framing member ll-threaded rod typical Strut or hanging device Uponor quapex pipe with insulation where required 4
5 Risers Risers typically feature Uponor quapex pipe in sizes from " to " with TS riser clamps at the base of each floor. The installation should also include a riser clamp at the top of every-other story to limit the expansion and contraction of the pipe to less than 5' (7.6m). This translates to an expansion of about " in 5' (7.6m) at a 60 F (4 ) Delta T [installed at 60 F (4 ) with an operating temperature of 0 F (48.9 )]. Detailed Riser Installation Uponor quapex pipe risers ppropriate firestop material (must be Uponor quapex compatible) In this application, the piping will snake slightly in areas where it is not constrained. Use discarded framing as a backer plate for the mid-story guide. Ensure the guide is metal with no sharp edges or fire-rated for risers in walls requiring fire-resistant construction. Through Penetrant Firestop The following firestop manufacturers offer PEX solutions as tested in accordance with N/UL S5. M TM Hilti HoldRite HydroFlame TM Metacaulk Nuo Passive Fire Protection Partners ProSet Systems Tremco See firestop manufacturer s website for selection of appropriate fire assembly and product. Plenum Rated Up to " piping in return-air plenums have no spacing limitations if covered with " fire-rated fiberglass insulation. Uninsulated 4" to " pipe in a return-air plenum must be separated by 8" (0.46m). Listing for " pipe does not specify restrictions on spacing requirements. Pipe larger than " may not be installed without " minimum fire-rated insulation. Exposed EP fittings are approved. Pipe in hallway drop-ceiling applications requires special attention due to variances and interpretations of anada building codes. lways check with local code officials before installing Uponor quapex in hallway drop ceilings. National uilding ode (N) Requirements for Plenums Materials exposed in plenums shall have a flame spread (FS) of 5 or less and a smoke developed (SD) of 50 or less when tested in accordance with N/UL S0.. " minimum fireresistant wrap, such as fiberglass insulation, will achieve 5 FS/50 SD classifications for Use appropriate floor assembly per code Use appropriate wall assembly per code Mid-story guide where required between each floor Riser clamp required at the base of each floor Wall-framing member Refer to appropriate fire assembly listing for penetration requirements Riser clamp at the top of every-other floor to limit expansion and contraction to 5' (7.6m) (if required) large-diameter Uponor quapex pipe, thus permitting installations in plenums, ceiling spaces and exposed locations. 5
6 ommercial Flush ank Section Detail Wall ssembly Uponor quapex pipe header (size varies) Support Uponor quapex pipe supply (size varies) Surge Pressure and Sound Intensity The main sources of sound in a water piping system are cavitation, surface roughness and water hammer caused by surge pressure. avitation is generally a design issue, so the question is which material will absorb more of the sound if it occurs? Typical polymers will absorb sound in the range of 0 d/cm, whereas metals are on the order of d/cm. For a given change in velocity, the intensity of sound from a copper pipe will be at least 8 times higher than that of PEX-a pipe and peak pressures caused by a quick-acting valve could be reduced by 8-40% by utilizing PEX-a in lieu of copper pipe. Surge Pressure Generated in Response to a Quick-acting Valve (PPI Report #85) Pipe Material Maximum Measured Pressure, psi Vent pipe Uponor ProPEX Lead-free (LF) rass Sweat dapter opper stub opper carrier bracket Water closet carrier quapex for Water Service pplications Uponor quapex Pipe is manufactured to meet the requirements of WW 904 rosslinked Polyethylene (PEX) Pressure Pipe, " (mm) Through " (76mm), for Water Service. This standard describes PEX pressure pipe made from materials having a minimum standard PEX material designation code of PEX 006 in STM F876 for use as underground water service lines in sizes ½" through " and conforms to a standard dimension ratio of SDR 9. Flow Rate, gpm " Uponor PEX-a " PEX-b " PV " Type L opper Pressure response measurements include 60 psi (44 kpa) static pressure. losing speed of quick-acting valve estimated at 5 milliseconds. Test performed at 54 F (. ) cold water temperature. PEX-a offers up to Install Uponor quapex pipe underground in a manner that ensures external loads will not subsequently cause a decrease in the vertical dimension of the cross section of the pipe that exceeds 5% of the outside diameter. Install Uponor quapex pipe in a snaking pattern with sufficient slack in the line to allow for contraction of the line due to temperature change prior to backfilling. Use ProPEX or approved WW 800 compression fittings to connect pipe to itself or to the corporation and curb stops. heck 40% reduction in surge pressure with Uponor or the fitting manufacturer for application suitability and proper usage instructions. Uponor EP and LF fittings are rated for direct burial in soil per NSF 4. Service Fitting Solution Providers Y McDonald ambridge rass Ford Pack Mueller 0 Philmac PolyGrip Fluorescent Lighting UV and Heat Exposure s a safety precaution against Ultraviolet (UV) exposure from fluorescent lighting, Uponor recommends that all PEX-a pipe be protected from UV by sleeving the pipe with a black material such as closed-cell pipe insulation or HDPE poly sheathing. Protection is recommended when pipe is directly exposed and within 6' (.8m) of the fluorescent light source. In such case, pipe should be protected 8" (0.46m) beyond direct exposure on each side of the fluorescent light source. Furthermore, Uponor requires that all PEX-a pipe be protected from excessive heat by insulating the pipe with closed-cell, fiberglass or other suitable pipe insulation. Insulation is required when pipe is within 6" (0.5m) of the fluorescent light source. In such case, pipe shall be protected 8" (0.46m) beyond each side of the fluorescent light source and maintain a minimum clearance of " (5.4mm). 6
7 " Uponor quapex Expansion Loop Expansion and ontraction ecause PEX pipe expands at a rate of." per 00' per 0 F (7.94mm per 0.48m per 5.56 ) temperature rise, an expansion joint, offset or change in direction is necessary to accommodate the expansion and contraction of the pipe. ompensation for expansion is typically needed every 65' for domestic hot water and every 50' for domestic cold water in a commercial domestic water plumbing system. Uponor offers a preformed " Uponor quapex Expansion Loop (F85000) to make expansion joint installations more efficient. Pre-insulated quapex R-value/Heat Loss Pipe Size R-value Heat Loss at 70 F ΔT ". 8.9 tu/(hr ft² F) 4".. tu/(hr ft² F) ".0. tu/(hr ft² F) 4".9 5. tu/(hr ft² F) ".8 7. tu/(hr ft² F) ".7.0 tu/(hr ft² F) Using " insulation Thermal onductivity PEX-a pipe has a very low coefficient of thermal conductivity, 0.9 tu/(hr ft² F), whereas copper has a coefficient of thermal conductivity between 00 and 400 tu/(hr ft² F) depending on wall thickness (Type K, L or M). Therefore, PEX-a pipe does not sweat like copper does. The thicker walls of PEX-a pipe act as an insulator (approx. R-0.9) whereas the heat transfer from copper is much greater than with PEX-a. Uponor recommends insulating all PEX-a domestic hot-water supply and return lines to conserve energy and insulating PEX-a domestic cold-water supply lines when installed in an unconditioned space or poorly ventilated areas with excessive moisture content. PEX-a vs. opper Heat Loss omparison tu/hr ft Pre-insulated Uponor quapex is available in: "-" pipe sizes with " PEX-foam insulation 4"-" pipe sizes with " PEX-foam insulation (special order) PEX-a offers up to 0% better insulation value Delta T ( F) FG Insulation Thickness (K=0.8) 0" " " " 0" " " " 0" " " " 0" " " " 0" " " " " 4" Uponor PEX-a Type L opper Uponor PEX-a Type L opper Nominal Pipe Sizes " 4" " Uponor PEX-a Type L opper Uponor PEX-a Type L opper Uponor PEX-a Type L opper " " Uponor PEX-a Type L opper Uponor PEX-a Type L opper
8 uilding Information Modeling (IM) utodesk Seek Uponor parts now available in utodesk Seek; search Uponor" on For use with Revit, utod, ds Max, Maya and other D applications uilding-dt.net/tsi Uponor parts now included in the uilding Data ontent Library for use with TSI MEP modeling software PLUMING SYSTEMS ommplu_refguide_p454_06_, opyright 0 Uponor. Printed in the United States 8 For more information, see the Uponor Plumbing Design ssistance Manual (PDM) Uponor, Inc th Street West pple Valley, MN 554 US Phone: Fax: Uponor Ltd. 000 rgentia Rd., Plaza, Ste. 00 Mississauga, ON L5N W ND Phone: Fax: Plumbing Design ssistance Manual (PDM) PDM_P_7-08, opyright 008 Uponor. Printed in the United States PLUMING D E S I G N S S I S T N E MNUL (PDM) Uponor Plumbing Design ssistance Manual (PDM) Uponorengineering.com The Engineer s Resource Portal The Uponor Engineering Resource enter is your single destination for designing and creating a desirable, cost-effective and energy-efficient structure. This portal is custom-made especially for you, the engineer, to help you meet all your goals. Whether it s meeting specific LEED or other green-building certification standards or incorporating value engineering into a project, Uponor can provide all the tools and resources, including specifications, submittals, D details, instructional manuals, design guidelines and even industry resource links to get you moving and on your way to a successful build. Uponor Ltd. 000 rgentia Rd., Plaza, Ste. 00 Mississauga, ON L5N W ND Tel: Fax:
PEX Pipes for Plumbing Applications
PEX Pipes for Plumbing Applications Introduction How PEX pipes are made Reasons for using PEX systems Industry standards and tests PEX joining systems Code acceptance Design considerations Installation
Engineering Specifications
PUREFLOW PEX PRODUCTS PART 1 GENERAL 1.1 SUMMARY 1.1.1 This specification covers Branch & Main, Parallel Water Distribution Systems (MANABLOC), Cross-linked Polyethylene tubing and fittings using PEX Press
4 Installation Requirements
4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming
PEX Pipes for Service Line Applications
PEX Pipes for Service Line Applications Introduction to PPI Introduction to PEX pipes for water service Industry standards and tests Reasons for using PEX pipes for water service PEX installation for water
Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls
Pre- insulated pipe systems ecoflex Wall Penetration installation guide Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls Pre-insulated Pipe Systems
OUTLINE. How PEX pipes are made Capabilities of PEX pipes, standards, testing PEX pipes for Plumbing and other applications
PEX Pipes for Plumbing Presented at the 40 th ASPE Convention, Oct 2004 Lance MacNevin, Chair, PPI High Temperature Plastics Division Camille George Rubeiz, P.E., Director of Engineering, PPI OUTLINE How
Zurn PEX Chlorine Resistance PEX 5006 Designation Generally a continuously circulating hot water plumbing loop @ 140 F.
The Zurn PEX Commercial Plumbing System This manual is an addendum to the Zurn PEX Plumbing Installation Guide, ZPM07199. Its purpose is to provide customers with addi - tional information relevant to
Tremco Fire Protection Systems Group Technical Bulletin
Compartmentalization products and design play a key role in protecting lives and property from fire. Understanding the tools and techniques available for firestopping is of utmost importance to designers,
DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS
DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS A. SCOPE 1. This information is intended to assist contractors, installers and code officials in the proper design and installation of flexible
C I T Y O F S E L M A F I R E D E P A R T M E N T
C I T Y O F S E L M A F I R E D E P A R T M E N T Informational Bulletin Regarding Residential Fire Sprinkler Systems for One and Two Family Homes: Frequently Asked Questions ADMINISTRATIVE PROVISIONS:
Excerpts from the Canadian National Building Code (NBC)
Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more
Draft Specification PEX tubing. Section 23 83 16. Radiant-Heating Hydronic Piping. (Roth Radiant Heating Systems)
This draft specification is for hydronic radiant heating systems using PEX tubing in slab, floor, wall and ceiling applications, and as distribution piping. Roth Industries supplies these systems under
PLUMBING SYSTEMS. Uponor Professional Plumbing Installation Guide
PLUMBING SYSTEMS Uponor Professional Plumbing Installation Guide Table of Contents Section 1: The Uponor Plumbing System..............1 Applications 1 Ratings, Standards, Listings and Codes 2 Ratings
Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector
Plumbing Helpful Hints Residential Construction Bert Polk Plumbing Inspector Lincoln County 2015 Waste and vent fittings Vent 90 medium 90 long 90 1/16 bend,1/8 bend,1/6 bend, medium 90 san tee combination
STRONG FLEXIBLE. HyperPure PURE
STRONG FLEXIBLE PURE TM HyperPure TM HyperPure 1954 HDPE (HIGH DENSITY POLYETHYLENE) TUBE FIRST TESTED 1965 ENGEL PATENT, PEXa 1967 PEXa PRODUCTION FOR POTABLE WATER SYSTEMS BIMODAL POLYETHYLENE RAISED
2014 British Columbia Building Code Changes
District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials
Cost Estimation for Materials and Installation of Hot Water Piping Insulation
Cost Estimation for Materials and Installation of Hot Water Piping Insulation Prepared for Pacific Northwest National Laboratory Under Contract Number: 18O9O2 By Gary Klein, Managing Partner Affiliated
SECTION 15140 - PIPE HANGERS AND SUPPORTS
Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the
SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT
SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe hangers and supports. 2. Hanger rods. 3. Inserts. 4. Flashing. 5. Equipment
Built to Last. Built for Beauty. Good. Solid. Logix. TM
Built to Last. Built for Beauty. Good. Solid. Logix. TM Quality, Value and Service Introducing LOGIX Insulated Concrete Forms. Based on the simple concept of interlocking blocks, LOGIX ICF gives you a
POTABLE PIPING SYSTEM
P R O D U C T I N S TA L L AT I O N G U I D E POTABLE PIPING SYSTEM Designed Especially for Contractors BOW SUPERPEX JANUARY 2008 PRODUCT INSTALLATION GUIDE IMPORTANT NOTICE The information in this manual
NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
EcoTouch Insulation with PureFiber Technology
PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
SECTION 15190 HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section 15010.
SECTION 15190 HVAC INSULATION PART ONE - GENERAL PART 1 - GENERAL 1.01 DESCRIPTION A. All work specified in this Section is subject to the provisions of Section 15010. B. All insulation products shall
SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS
SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such
Retardants Inc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318
Fire Barrier Moldable Putty+ Pads 123 Columbia Court North Suite 201 Chaska, MN 55318 952-448-7377 FAX:952-448-2613 e-mail: [email protected] Visit Our Web Site at www.fireretardantsinc.com Protecting
Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware.
14 gauge stainless steel The Original, Long Life Sanitary Guide Rail Valu Guide rail incorporates two outstanding materials: stainless steel and UHMW. The 14 ga. stainless steel sheath provides rigid streamlined
Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit
R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed
This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD
SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board, vapor retarder and air and moisture barrrier. 1.2 RELATED WORK A. Installation
One of the fundamental design elements that every
Preliminary Design Information Before starting the water system design, you must assemble a collection of information. This includes information from the owner, the local utility, and the architect. Things
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT
PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT GENERAL INFORMATION 1.1 This section applies to piping systems for chilled water, hot water, condenser water, steam, condensate return, fuel oil, refrigerant
Fiberglas, Exterior Wall Thermal Insulation
PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
800 Communications Circuits
ARTICLE 800 Communications Circuits INTRODUCTION TO ARTICLE 800 COMMUNICATIONS CIRCUITS This article has its roots in telephone technology. Consequently, it addresses telephone and related systems that
FLEX-WRAP Foam Pipe Wrap
FLEX-WRAP Foam Pipe Wrap Flex-wrap Inexpensive Used to wrap all pipes in a concrete pour Satisfies UPC Code Sec.315.7 Provides true expansion space between pipe and a concrete pour Product # Dimesions
PEX TUBING FAQ WHAT IS PEX?
PEX TUBING FAQ WHAT IS PEX? Pex is cross-linked polyethylene. Through one of several processes, links between polyethylene macromolecules are formed to create bridges between PE molecules (thus the term
Final inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability
1/9/13 By Brett T. Fagan, P.E. Presented by Marie Horan, P.E. Building Diagnostics, Inc. Building Diagnostics Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability
MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water
MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water 105 Decker Court, Suite 825, Irving, TX 75062 P: 469-499-1044 F: 469-499-1063 www.plasticpipe.org HDPE
All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition.
DIVISION 15 MECHANICAL SECTION 15100 - PLUMBING PART 1 - GENERAL SCOPE Plumbing work includes all domestic water, gas, and sanitary sewer systems as shown on plans. Also all fixtures and equipment which
DESIGN GUIDE Residential PEX Water Supply Plumbing Systems
DESIGN GUIDE Residential PEX Water Supply Plumbing Systems Prepared for Plastics Pipe Institute, Inc (PPI) 105 Decker Court Suite 825 Irving, TX 75062 www.plasticpipe.org and Plastic Pipe and Fittings
Saves time. Saves money. Up to 2 size for commercial gas piping.
Flexible Gas Piping by OmegaFlex Saves time. Saves money. Up to 2 size for commercial gas piping. Cost-effective, safe and completely reliable, TracPipe/CounterStrike is the ideal pipe for new construction,
Heating Load Calculation
Heating Load Calculation ME 425 Air Conditioning System Design Keith E. Elder, P.E. Heating Load Calculation The heating load calculation begins with the determination of heat loss through a variety of
DESIGN GUIDE Residential PEX Water Supply Plumbing Systems
DESIGN GUIDE Residential PEX Water Supply Plumbing Systems Second Edition Prepared for Plastics Pipe Institute, Inc (PPI) 105 Decker Court Suite 825 Irving, TX 75062 www.plasticpipe.org and Plastic Pipe
ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:
ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to
Value Engineering Considerations for Cast Iron Soil Pipe and PVC in Commercial Sanitary and Storm Drainage Applications
Value Engineering Considerations for Cast Iron Soil Pipe and PVC in Commercial Sanitary and Storm Drainage Applications BR-VEC (2-14-13) The Correct Material for the Correct Application Plumbing design
Complete Firestop Systems Guide
Complete Firestop Systems Guide Passive Fire Protection products are tested to various test requirements, please check with your local building code for the requirements within your municipality. Firestop
Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings
BUILDING ENVELOPE DESIGN BY ROXUL Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB Fire Rated Board Insulation for Pre-Engineered Metal Buildings ROXUL FIREWALL & ROXUL PLUS MB Exterior
APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM
APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM Because of the variable conditions encountered, it is impractical to lay down definite detailed rules of procedure for determining the sizes
Green Thread Product Data
Green Thread Product Data Applications Dilute Acids Caustics Produced Water Industrial Waste Hot Water Condensate Return Materials and Construction All pipe manufactured by filament winding process using
Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork
Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork HVAC - Fire protection of metal ductwork Fire protection Thermal insulation Isover ULTIMATE TM Protect - Fire protection
WHI 90-Minute Rated Veneered Door Frame Installation Instructions
No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,
Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings
Building Envelope Design using ROXUL Building Envelope Design using ROXUL (BEDR ) FIREWALL and ROXUL PLUS MB Fire Rated Board Insulation for Pre-Engineered Metal Buildings ROXUL FIREWALL & ROXUL PLUS MB
INTER-NOISE 2006 3-6 DECEMBER 2006 HONOLULU, HAWAII, USA
INTER-NOISE 2006 3-6 DECEMBER 2006 HONOLULU, HAWAII, USA An effective new approach to isolate plumbing stub-outs in residential construction Jeffrey P. Kwolkoski, P.E., INCE Bd. Cert. a D. L. Adams Associates,
2006 Codes. Please verify the following before calling for inspection
INSPECTION CHECKLIST RESIDENTIAL PLUMBING ROUGH IN 2006 Codes This checklist is intended for use to prepare for an inspection. This is only a general list and is not intended to address all possible conditions.
STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual
STATFlow Direct-to-Drain System For use with STATIM 2000 and STATIM 5000 Autoclaves Installation Guide and Operator s Manual STATFlow Installation Guide and Operator s Manual 95-113193 Rev 2.0. Copyright
Chapter 7 Plumbing Connections
Chapter 7 Plumbing Connections 7-1 General All plumbing equipment and installations must be designed, constructed, and installed in accordance with this code and where not specific, to the applicable provisions
Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in
REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory
Formwork for Concrete
UNIVERSITY OF WASHINGTON DEPARTMENT OF CONSTRUCTION MANAGEMENT CM 420 TEMPORARY STRUCTURES Winter Quarter 2007 Professor Kamran M. Nemati Formwork for Concrete Horizontal Formwork Design and Formwork Design
60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING
60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed
Residential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
BUILDING SAFETY UNIT
POLICY Page 1 of 5 SUBMITTAL REQUIREMENTS FOR ONE AND TWO FAMILY DWELLINGS, ADDITIONS AND RENOVATIONS All submittals shall be site specific and designed to the provisions of the 2012 International Residential
HVAC Air Duct Leakage. Eli P. Howard, III Group Director Technical Resources SMACNA
HVAC Air Duct Leakage Eli P. Howard, III Group Director Technical Resources SMACNA Key Variables that Affect the Amount of Leakage Static Pressure Amount of Duct Openings in the Duct Surface Seams, Joints,
505.3.6 For a building with a crawl space, see Figure 10. 505-1
505 WATER SERVICE INSTALLATION 505.1 DEFINITION A service line is comprised of the piping and related appurtenances including the connection installed from the Des Moines Water Works water main to the
Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers
City of Duluth Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers Thank you for taking the time to join us today. We know you are busy and your time is valuable.
CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM
Pyrotenax SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM Contents Introduction This section provides an overview of general circuit design considerations and installation guidelines for a Pyrotenax System
Electrical Wiring Technical Bulletin
Electrical Wiring Technical Bulletin Overview In general, SIP construction is easier and more cost effective when things are planned and thought out before the panels are manufactured. This process will
INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings
INSULATION FOR PRE-ENGINEERED METAL BUILDINGS ROXUL SAFE 55 & 65 and ROXUL PLUS MB Insulation for Pre-Engineered Metal Buildings ROXUL SAFE AND ROXUL PLUS MB Exterior Wall Insulation for Pre-Engineered
HOW TO INSULATE A CRAWLSPACE
HOW TO INSULATE A CRAWLSPACE Many homes throughout the United States have what are commonly referred to as crawlspaces. Crawlspaces are open spaces underneath a portion of a home. They are very common
Top 10+ Mistakes of DWV plumbing design
Top 10+ Mistakes of DWV plumbing design Listed below are the some of the most frequently missed items, noticed by our inspectors, at plumbing rough-in when non-plumbers attempt plumbing design. Most of
Refrigeration Installation 101
Refrigeration Installation 101 Hundreds of Installations Refrigerated Cases 2 Compressor Racks 3 Condensing Units 4 Walk-in Boxes 5 Some were done very well 6 Some had some issues... 7 8 Some seemingly
Fire Barrier Duct Wrap 15A
3 Fire Barrier Duct Wrap 15A Commerical Kitchen Grease Duct Fire Protection System Product Data and Installation Instructions Compliance 1998 Edition Complies with International Mechanical Code Complies
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders
BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.
SUBMERSIBLE PUMP selection A submersible pump consists of the following basic elements: < Bowl Assembly < Motor < Cable < Drop Pipe < Surface Plate (with)(without) discharge elbow DATA REQUIRED FOR SELECTION
Building Code Clarifications - 7. Fire Resistance
Building Code Clarifications - 7. Fire Resistance 7.1 (15-12-030) Use of combustibles in Type III construction roof assemblies Code Section (15-12-030) Use of Combustibles was revised on May 17, 2000,
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS 1. SCOPE 1.1 This specification covers the type, physical properties and dimensions of Expanded Polystyrene Insulation Board intended for use
Uponor Professional Plumbing Installation Guide Hot and Cold Potable Water Systems PLUMBING SYSTEMS HOT AND COLD POTABLE WATER SYSTEMS
PLUMBING SYSTEMS HOT AND COLD POTABLE WATER SYSTEMS INSTALLATION GUIDE Uponor Professional Plumbing Installation Guide Hot and Cold Potable Water Systems Uponor Professional Plumbing Installation Guide
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,
The surface roughness of the polyurethane lining is 10 times lower than cement-lined pipes.
QUALITY INSIDE When it comes to long life piping for drinking water, sewage, industrial water or gas, there is one name that continues to lead the way - ECOPUR by vonroll. Delivering precision-engineered
HV AC CODE CHECKLISTS
The following text is informational only and shall serve as an informational guide for HV AC contractors, journeymen, and apprentices working in the Heating, Ventilation, and Air Conditioning industry.
SIZING OF WATER PIPING SYSTEM
SIZING OF WATER PIPING SYSTEM SECTION E101 GENERAL E101.1 Scope. E101.1.1 This appendix outlines two procedures for sizing a water piping system (see Sections E103.3 and E201.1). The design procedures
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines
EXHIBIT "A Technical Specifications for Water and Sewer Service Lines Water and Sewer Line Bedding and Backfill: Drawings show cross-section of trench, pipe laid on top of 6" min. bedding material, bedding
INSTALLATION GUIDE. americanwick.com 800.242.WICK (9425)
INSTALLATION GUIDE americanwick.com 800.242.WICK (9425) American Wick Drain SITEDRAIN prefabricated drainage products may be installed in a variety of civil construction applications including: retaining
Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes
CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL
Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996
CITY OF SAN JOSE BUILDING DIVISION POLICY Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996 All new and replacement water heaters installed
Fire Barriers & Fire Stopping
Presented by: Bill Lauzon, PE Lauzon Life Safety Consulting, LLC 262-945-4567 [email protected] Web: Lauzon-LSC.com Environmental Part 2 Life Safety Code Chapter 8 Fire Barriers & Fire Stopping 1 Fire
Surge Pressure in Plumbing Pipe Materials
Surge Pressure in Plumbing Pipe Materials Prepared for Plastics Pipe Institute, Inc. 15 Decker Court, Suite 825 Irving, Texas 7562 Prepared by NAHB Research Center 4 Prince George s Blvd. Upper Marlboro,
Solid shape molding is not desired in injection molding due to following reasons.
PLASTICS PART DESIGN and MOULDABILITY Injection molding is popular manufacturing method because of its high-speed production capability. Performance of plastics part is limited by its properties which
Zurn PEX Plumbing Design and Application Guide. Zurn PEX Tubing and Fittings. Certified
Zurn PEX Tubing and Fittings Certified Notice: This manual contains recommended installation instructions for Zurn PEX hot and cold water systems. Failure to observe these installation instructions may
B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
TEXAS A&M CENTRAL ACADEMIC BUILDIING & PATRIOT S CASA SUBMITTAL. 23 21 13.19 Pre-Insulated Piping 4-8-13
TEXAS A&M CENTRAL ACADEMIC BUILDIING & PATRIOT S CASA SUBMITTAL 23 21 13.19 Pre-Insulated Piping 4-8-13 MATERIAL SUBMITTAL JOB NAME: TEXAS A&M SAN ANTONIO CENTRAL ACADEMIC BUILDING & PATRIOTS CASA CONTRACTOR:
building applications copper - redefined
building applications copper - redefined copper - redefined The task The development of an innovative tube for the future: economical, environmentally friendly, ecological, completely safe and easy to