1 An In-Depth Look at Variable Stripe RAID (VSR) A white paper by Robbie Stevens, Senior Marketing/Technical Writer Westheimer Rd. Houston, TX Scan this QR code with your smartphone for more information on Variable Stripe RAID. Download a QR scanner here:
2 Table of Contents Introduction... 3 Background Information... 4 Flash Architecture... 4 Bad Blocks Lead to Plane Failure... 5 RAID Arrays... 5 Prior RamSan RAID Implementation... 5 Variable Stripe RAID... 7 Advantages vs. Traditional RAID... 7 Advantages vs. Competition... 8 Conclusion... 9 Variable Stripe RAID (VSR) 2 June 2011
3 Introduction Variable Stripe RAID (VSR) is a new feature from Texas Memory Systems (TMS) that reduces the risk of uncorrectable errors occurring in user data on a NAND Flash chip while preserving as much storage space as possible. VSR maximizes chip storage space since it is not necessary to relocate an entire stripe following a failure. TMS now offers products with VSR incorporated into their Flash controllers, allowing stripes containing bad planes to be seamlessly rebuilt and efficiently relocated. By dynamically altering the stripe size, VSR can drastically reduce wasted planes. Variable Stripe RAID (VSR) 3 June 2011
4 Background Information Flash Architecture Flash is a type of non-volatile, solid state storage technology. In enterprise applications, multiple Flash chips are used together to produce solid state disks (SSDs) in the form of external rackmount systems or internal cards or drives. A Flash memory chip is divided into multiple nested entities. The 32nm Toshiba Flash chips used by the TMS Series-7 RamSan systems are divided as follows: One chip: is divided into 8 dies: One die is divided into 2 planes: One plane is divided into 2,048 blocks: One block is divided into 64 pages: Variable Stripe RAID (VSR) 4 June 2011
5 One page is divided into 8,192 bytes: In total, each chip contains 8 dies, 16 planes, 32,768 blocks, 2,097,152 pages, and 17,179,869,184 bytes! Bad Blocks Lead to Plane Failure A block may fail for a number of reasons. While many of these errors are automatically corrected using an error-correcting code (ECC), sometimes errors occur that ECC cannot handle. For example, a block may be worn past its usable life or data may be unintentionally altered through instances called read-, write-, and erase-disturb errors. If a block cannot be erased or written to, or if a read fails with uncorrectable ECC errors (that is, ECC cannot correct errors because too many bytes have failed), the PowerPC CPU in the Series-7 Flash Controller marks the block as bad and attempts to recover its data, if possible. Plane failure occurs if enough blocks within a plane go bad (256 for TMS systems). Failed planes can no longer be used to store data. RAID Arrays RAID (Redundant Array of Independent Disks) arrays are a popular way to mitigate the risks of losing data on an SSD in the event of a failed chip. In many RAID implementations, data is striped across all chips in an SSD, and if one chip fails the information on the remaining chips can be used to rebuild the missing data. The types of RAID arrays used in RamSan systems stripe data across all chips. For example, a RamSan-70 uses 40 chips and four Flash controllers in its base configuration. Each RamSan-70 Flash controller connects to ten Flash chips and is initially set up to use a 9+1 rolling XOR RAID across all ten of its Flash chips. Nine data pages within each RAID stripe are protected by a tenth page of additional information that can be used to rebuild lost data in the event of uncorrectable data errors. Prior RamSan RAID Implementation All RamSan systems operate as RAID arrays (in most cases, they have used RAID-5). If a bad plane was detected, the controller automatically rebuilt the missing block and moved all data from that stripe to a new location. All blocks used by that stripe were then deactivated. Variable Stripe RAID (VSR) 5 June 2011
6 Many RAID-5 controllers automatically detect plane failure and rebuild the data elsewhere much like VSR does, increasing data stability. However, the reduction in usable capacity within one device limits the overall number of stripes that can be created within the entire group. If a single device loses one eighth of its available blocks due to a failure, then all other devices within the RAID group also see a capacity reduction of one eighth. Once all available capacity in the failing device has been utilized, then no more stripes may be created, even if unused capacity still remains within the functioning devices. In the case of a 9+1 stripe, one bad plane results in nine good planes going to waste. In an extreme case, an entire chip may fail. Such a condition prevents the creation of any new stripes, and renders the entire RAID group unusable. Over time, the number of good planes trapped in bad stripes can reduce storage capacity by a significant amount. Variable Stripe RAID (VSR) 6 June 2011
7 Variable Stripe RAID When a bad plane occurs, VSR technology allows a plane to be removed from use without impacting the available capacity of other devices within the RAID stripe. Upon detection of a failure, the failing plane is removed from use (no further writes are allowed) and all used pages within the affected stripe are marked as critical to move. Information from the affected stripe is then gradually relocated to knowngood stripes, a process that is performed as a background task to minimize the required processing power. Unlike traditional RAID, the loss of capacity in one device does not affect other devices. The functioning devices those having more available capacity than that of the failing device simply create stripes with fewer pages (such as 8 +1 instead of 9+1) to work around the failing plane. Even in the event of complete chip loss, new stripes may be created across the remaining good chips and the failing chip is simply taken out of circulation. With VSR technology, device failures result in far less capacity loss than traditional RAID. Advantages vs. Traditional RAID In a traditional RAID-5 array, a stripe can only survive the failure of one plane used by the stripe. If a second plane in a stripe fails and the data has not been relocated by the controller, the entire stripe is corrupted, resulting in data loss. In addition, if the stripe is relocated by the controller, the planes used by the original stripe are deactivated. For example, suppose one plane in a 9+1 rolling XOR RAID-5 array fails (in this case, plane 6 1 ): When the failed plane is detected, the data is rebuilt and moved to a new stripe, along with the other data in the stripe: P 2 The original ten planes can then no longer be used: In a VSR array, when a plane fails, the data from that stripe is rebuilt and moved to a new stripe in a similar fashion. However, the failed plane is removed from the original stripe, allowing the stripe to be used for new data. While the failed plane cannot be reused, the other nine planes are retained and additional data can be striped across them. For example, if the stripe was originally set up using a 9+1 Variable Stripe RAID (VSR) 7 June 2011
8 rolling XOR RAID, once the failed plane is removed the stripe functions as an 8+1 rolling XOR stripe. Suppose one plane in a 9+1 rolling XOR VSR RAID array fails (again, plane 6 1 ): When the failed plane is detected, the data is rebuilt and moved (along with the other data in the stripe) to a new stripe, similar to RAID-5: P 2 However, VSR striping allows the original stripe to be reused. Only the failed plane is deactivated, resulting in an 8+1 rolling XOR VSR RAID stripe for new data: Furthermore, the new 8+1 RAID stripe can survive another bad plane. Suppose a plane fails in the new stripe: The stripe is rebuilt and moved to a new location, and the remaining 7+1 stripe is made available for new data P 3 Since VSR salvages the good planes in a stripe containing a failed plane, much more storage space is retained. Advantages vs. Competition This technology is only available from Texas Memory Systems, a company committed to producing the fastest, most reliable enterprise storage available. TMS uses only single-level cell (SLC) Flash chips, which have a much longer (10x) expected life than the multi-level cell (MLC) chips used in competing products. By reducing space lost to failed planes, VSR technology is another way TMS extends the usable life and value of its products. Variable Stripe RAID (VSR) 8 June 2011
9 Conclusion Variable Stripe RAID technology from Texas Memory Systems extends the usable life of its storage solutions, helping enterprise SSD users retain as much storage space as possible while protecting the integrity of their data. When VSR striping is employed, data from a failed plane is rebuilt and the plane is relocated. More importantly, the stripe containing the failed plane is not discarded; instead the failed plane is simply removed from the stripe, allowing new data to be written to the stripe. Since VSR technology automatically and dynamically adjusts stripe width following plane failure, this new RAID strategy can reduce wasted planes and efficiently protect valuable data. Variable Stripe RAID (VSR) 9 June 2011
An In-Depth Look at the RamSan-810 Flash Solid State Disk
An In-Depth Look at the RamSan-810 Flash Solid State Disk A white paper by Robbie Stevens, Senior Marketing/Technical Writer Web: RamSan.com Facebook: facebook.com/texasmemorysystems Twitter: @TexasMemory
High-Performance SSD-Based RAID Storage. Madhukar Gunjan Chakhaiyar Product Test Architect
High-Performance SSD-Based RAID Storage Madhukar Gunjan Chakhaiyar Product Test Architect 1 Agenda HDD based RAID Performance-HDD based RAID Storage Dynamics driving to SSD based RAID Storage Evolution
PIONEER RESEARCH & DEVELOPMENT GROUP
SURVEY ON RAID Aishwarya Airen 1, Aarsh Pandit 2, Anshul Sogani 3 1,2,3 A.I.T.R, Indore. Abstract RAID stands for Redundant Array of Independent Disk that is a concept which provides an efficient way for
Advantages of e-mmc 4.4 based Embedded Memory Architectures
Embedded NAND Solutions from 2GB to 128GB provide configurable MLC/SLC storage in single memory module with an integrated controller By Scott Beekman, senior business development manager Toshiba America
The Technologies & Architectures. President, Demartek
Deep Dive on Solid State t Storage The Technologies & Architectures Dennis Martin Dennis Martin President, Demartek Demartek Company Overview Industry analysis with on-site test lab Lab includes servers,
Ensuring Robust Data Integrity
TECHNICAL WHITE PAPER Ensuring Robust Data Integrity www.tintri.com Executive Summary Purpose-built storage appliances serving enterprise workloads typically use commodity hardware with value-added OS
Important Differences Between Consumer and Enterprise Flash Architectures
Important Differences Between Consumer and Enterprise Flash Architectures Robert Sykes Director of Firmware Flash Memory Summit 2013 Santa Clara, CA OCZ Technology Introduction This presentation will describe
Understanding endurance and performance characteristics of HP solid state drives
Understanding endurance and performance characteristics of HP solid state drives Technology brief Introduction... 2 SSD endurance... 2 An introduction to endurance... 2 NAND organization... 2 SLC versus
Endurance Models for Cactus Technologies Industrial-Grade Flash Storage Products. White Paper CTWP006
Endurance Models for Cactus Technologies Industrial-Grade Flash Storage Products White Paper CTWP006 Cactus Technologies Limited Suite C, 15/F, Capital Trade Center 6 Tsun Yip Street, Kwun Tong Kowloon,
SSD Performance Tips: Avoid The Write Cliff
ebook 100% KBs/sec 12% GBs Written SSD Performance Tips: Avoid The Write Cliff An Inexpensive and Highly Effective Method to Keep SSD Performance at 100% Through Content Locality Caching Share this ebook
Trends in NAND Flash Memory Error Correction
Trends in NAND Flash Memory Error Correction June 2009 Eric Deal Cyclic Design Introduction NAND Flash is a popular storage media because of its ruggedness, power efficiency, and storage capacity. Flash
Don t Let RAID Raid the Lifetime of Your SSD Array
Don t Let RAID Raid the Lifetime of Your SSD Array Sangwhan Moon Texas A&M University A. L. Narasimha Reddy Texas A&M University Abstract Parity protection at system level is typically employed to compose
Database!Fatal!Flash!Flaws!No!One! Talks!About!!!
MarcStaimer,President&CDSDragonSlayerConsulting W h i t e P A P E R DatabaseFatalFlashFlawsNoOne TalksAbout AndHowtoAvoidThem WHITEPAPER DatabaseFatalFlashFlawsNoOneTalksAbout AndHowtoAvoidThem DatabaseFatalFlashFlawsNoOneTalksAbout
Solid State Storage in Massive Data Environments Erik Eyberg
Solid State Storage in Massive Data Environments Erik Eyberg Senior Analyst Texas Memory Systems, Inc. Agenda Taxonomy Performance Considerations Reliability Considerations Q&A Solid State Storage Taxonomy
NAND Flash FAQ. Eureka Technology. apn5_87. NAND Flash FAQ
What is NAND Flash? What is the major difference between NAND Flash and other Memory? Structural differences between NAND Flash and NOR Flash What does NAND Flash controller do? How to send command to
Flash 101. Violin Memory Switzerland. Violin Memory Inc. Proprietary 1
Flash 101 Violin Memory Switzerland Violin Memory Inc. Proprietary 1 Agenda - What is Flash? - What is the difference between Flash types? - Why are SSD solutions different from Flash Storage Arrays? -
Flash s Role in Big Data, Past Present, and Future OBJECTIVE ANALYSIS. Jim Handy
Flash s Role in Big Data, Past Present, and Future Jim Handy Tutorial: Fast Storage for Big Data Hot Chips Conference August 25, 2013 Memorial Auditorium Stanford University OBJECTIVE ANALYSIS OBJECTIVE
Definition of RAID Levels
RAID The basic idea of RAID (Redundant Array of Independent Disks) is to combine multiple inexpensive disk drives into an array of disk drives to obtain performance, capacity and reliability that exceeds
NAND Basics Understanding the Technology Behind Your SSD
03 Basics Understanding the Technology Behind Your SSD Although it may all look the same, all is not created equal: SLC, 2-bit MLC, 3-bit MLC (also called TLC), synchronous, asynchronous, ONFI 1.0, ONFI
Yaffs NAND Flash Failure Mitigation
Yaffs NAND Flash Failure Mitigation Charles Manning 2012-03-07 NAND flash is one of very few types of electronic device which are knowingly shipped with errors and are expected to generate further errors
All-Flash Storage Solution for SAP HANA:
All-Flash Storage Solution for SAP HANA: Storage Considerations using SanDisk Solid State Devices WHITE PAPER 951 SanDisk Drive, Milpitas, CA 95035 www.sandisk.com Table of Contents Preface 3 Why SanDisk?
Solid State Drive Technology
Technical white paper Solid State Drive Technology Differences between SLC, MLC and TLC NAND Table of contents Executive summary... 2 SLC vs MLC vs TLC... 2 NAND cell technology... 2 Write amplification...
SLC vs MLC: Proper Flash Selection for SSDs in Industrial, Military and Avionic Applications. A TCS Space & Component Technology White Paper
SLC vs MLC: Proper Flash Selection for SSDs in Industrial, Military and Avionic Applications A TCS Space & Component Technology White Paper Introduction As with most storage technologies, NAND Flash vendors
Destroying Flash Memory-Based Storage Devices (draft v0.9)
Destroying Flash Memory-Based Storage Devices (draft v0.9) Dr. Steven Swanson Director, Non-volatile Systems Laboratory Department of Computer Science and Engineering University of California, San Diego
NAND Flash Media Management Through RAIN
Flash Media Management Through RAIN Scott Shadley, Senior roduct Marketing Manager Micron Technology, Inc. Technical Marketing Brief What Is RAIN, and Why Do SSDs Need It? This brief compares redundant
Data Retention in MLC NAND Flash Memory: Characterization, Optimization, and Recovery
Data Retention in MLC NAND Flash Memory: Characterization, Optimization, and Recovery Yu Cai, Yixin Luo, Erich F. Haratsch*, Ken Mai, Onur Mutlu Carnegie Mellon University, *LSI Corporation 1 Many use
SLC vs MLC: Which is best for high-reliability apps?
SLC vs MLC: Which is best for high-reliability apps? Here's an examination of trade-offs, with an emphasis on how they affect the reliability of storage targeted at industrial, military and avionic applications.
O&O Defrag and Solid State Drives
O&O Defrag Summary Solid State Drives (SSD or flash drives ) have become increasingly popular in recent years and have come to compete with traditional hard drives as very fast storage media. The sole
In-Block Level Redundancy Management for Flash Storage System
, pp.309-318 http://dx.doi.org/10.14257/ijmue.2015.10.9.32 In-Block Level Redundancy Management for Flash Storage System Seung-Ho Lim Division of Computer and Electronic Systems Engineering Hankuk University
Disks and RAID. Profs. Bracy and Van Renesse. based on slides by Prof. Sirer
Disks and RAID Profs. Bracy and Van Renesse based on slides by Prof. Sirer 50 Years Old! 13th September 1956 The IBM RAMAC 350 Stored less than 5 MByte Reading from a Disk Must specify: cylinder # (distance
Solid State Technology What s New?
Solid State Technology What s New? Dennis Martin, President, Demartek www.storagedecisions.com Agenda: Solid State Technology What s New? Demartek About Us Solid-state storage overview Types of NAND flash
MCF54418 NAND Flash Controller
Freescale Semiconductor Application Note Document Number: AN4348 Rev. 0, 09/2011 MCF54418 NAND Flash Controller by: Liew Tsi Chung Applications Engineer 1 Introduction The ColdFire MCF5441x family is the
Choosing the Right NAND Flash Memory Technology
Choosing the Right NAND Flash Memory Technology A Basic Introduction to NAND Flash Offerings Dean Klein Vice President of System Memory Development Micron Technology, Inc. Executive Summary A 75% increase
Building Flexible, Fault-Tolerant Flash-based Storage Systems
Building Flexible, Fault-Tolerant Flash-based Storage Systems Kevin M. Greenan Darrell D.E. Long Ethan L. Miller Thomas J. E. Schwarz, S.J. Avani Wildani Univ. of California, Santa Cruz Santa Clara University
Impact of Stripe Unit Size on Performance and Endurance of SSD-Based RAID Arrays
1 Impact of Stripe Unit Size on Performance and Endurance of SSD-Based RAID Arrays Farzaneh Rajaei Salmasi Hossein Asadi Majid GhasemiGol [email protected] [email protected] [email protected]
21 st Century Storage What s New and What s Changing
21 st Century Storage What s New and What s Changing Randy Kerns Senior Strategist Evaluator Group Overview New technologies in storage - Continued evolution - Each has great economic value - Differing
COS 318: Operating Systems. Storage Devices. Kai Li and Andy Bavier Computer Science Department Princeton University
COS 318: Operating Systems Storage Devices Kai Li and Andy Bavier Computer Science Department Princeton University http://www.cs.princeton.edu/courses/archive/fall13/cos318/ Today s Topics! Magnetic disks!
A Flash Storage Technical. and. Economic Primer. and. By Mark May Storage Consultant, By James Green, vexpert Virtualization Consultant
A Flash Storage Technical and Economic Primer y Mark May Storage Consultant, y James Green, vexpert Virtualization Consultant and Scott D. Lowe, vexpert Co-Founder, ActualTech Media March, 2015 Table of
End to End Data Path Protection
End to End Data Path Protection Application Note AN004 February 2012 Corporate Headquarters: 39870 Eureka Dr., Newark, CA 94560, USA Tel:(510) 623 1231 Fax:(510) 623 1434 E mail: [email protected]
RAID Technology Overview
RAID Technology Overview HP Smart Array RAID Controllers HP Part Number: J6369-90050 Published: September 2007 Edition: 1 Copyright 2007 Hewlett-Packard Development Company L.P. Legal Notices Copyright
VERY IMPORTANT NOTE! - RAID
Disk drives are an integral part of any computing system. Disk drives are usually where the operating system and all of an enterprise or individual s data are stored. They are also one of the weakest links
Addressing Fatal Flash Flaws That Plague All Flash Storage Arrays
Addressing Fatal Flash Flaws That Plague All Flash Storage Arrays By Scott D. Lowe, vexpert Co-Founder, ActualTech Media February, 2015 Table of Contents Introduction: How Flash Storage Works 3 Flash Storage
Database Hardware Selection Guidelines
Database Hardware Selection Guidelines BRUCE MOMJIAN Database servers have hardware requirements different from other infrastructure software, specifically unique demands on I/O and memory. This presentation
Booting from NAND Flash Memory
Booting from NAND Flash Memory Introduction NAND flash memory technology differs from NOR flash memory which has dominated the embedded flash memory market in the past. Traditional applications for NOR
OCZ s NVMe SSDs provide Lower Latency and Faster, more Consistent Performance
OCZ s NVMe SSDs provide Lower Latency and Faster, more Consistent Performance by George Crump, Lead Analyst! When non-volatile flash memory-based solid-state drives (SSDs) were introduced, the protocol
RAID Implementation for StorSimple Storage Management Appliance
RAID Implementation for StorSimple Storage Management Appliance Alpa Kohli June, 2012 KB-00008 Document Revision 1 StorSimple knowledge base articles are intended to provide customers with the information
Storage Technologies for Video Surveillance
The surveillance industry continues to transition from analog to digital. This transition is taking place on two fronts how the images are captured and how they are stored. The way surveillance images
PowerProtector: Superior Data Protection for NAND Flash
PowerProtector: Superior Data Protection for NAND Flash Introduction The unstable power conditions of outdoor applications such as transportation, telecommunications/networking and embedded systems run
SSDs and RAID: What s the right strategy. Paul Goodwin VP Product Development Avant Technology
SSDs and RAID: What s the right strategy Paul Goodwin VP Product Development Avant Technology SSDs and RAID: What s the right strategy Flash Overview SSD Overview RAID overview Thoughts about Raid Strategies
Samsung 3bit 3D V-NAND technology
White Paper Samsung 3bit 3D V-NAND technology Yield more capacity, performance and power efficiency Stay abreast of increasing data demands with Samsung's innovative vertical architecture Introduction
RAID Overview 91.520
RAID Overview 91.520 1 The Motivation for RAID Computing speeds double every 3 years Disk speeds can t keep up Data needs higher MTBF than any component in system IO Performance and Availability Issues!
DELL SOLID STATE DISK (SSD) DRIVES
DELL SOLID STATE DISK (SSD) DRIVES STORAGE SOLUTIONS FOR SELECT POWEREDGE SERVERS By Bryan Martin, Dell Product Marketing Manager for HDD & SSD delltechcenter.com TAB LE OF CONTENTS INTRODUCTION 3 DOWNFALLS
XtremIO DATA PROTECTION (XDP)
White Paper XtremIO DATA PROTECTION (XDP) Flash-Specific Data Protection, Provided by XtremIO (Ver..0) Abstract This white paper introduces the and discusses its benefits and advantages over RAID, with
Technologies Supporting Evolution of SSDs
Technologies Supporting Evolution of SSDs By TSUCHIYA Kenji Notebook PCs equipped with solid-state drives (SSDs), featuring shock and vibration durability due to the lack of moving parts, appeared on the
The What, Why and How of the Pure Storage Enterprise Flash Array
The What, Why and How of the Pure Storage Enterprise Flash Array Ethan L. Miller (and a cast of dozens at Pure Storage) What is an enterprise storage array? Enterprise storage array: store data blocks
Introduction. What is RAID? The Array and RAID Controller Concept. Click here to print this article. Re-Printed From SLCentral
Click here to print this article. Re-Printed From SLCentral RAID: An In-Depth Guide To RAID Technology Author: Tom Solinap Date Posted: January 24th, 2001 URL: http://www.slcentral.com/articles/01/1/raid
Physical Data Organization
Physical Data Organization Database design using logical model of the database - appropriate level for users to focus on - user independence from implementation details Performance - other major factor
DELL RAID PRIMER DELL PERC RAID CONTROLLERS. Joe H. Trickey III. Dell Storage RAID Product Marketing. John Seward. Dell Storage RAID Engineering
DELL RAID PRIMER DELL PERC RAID CONTROLLERS Joe H. Trickey III Dell Storage RAID Product Marketing John Seward Dell Storage RAID Engineering http://www.dell.com/content/topics/topic.aspx/global/products/pvaul/top
Technology Update White Paper. High Speed RAID 6. Powered by Custom ASIC Parity Chips
Technology Update White Paper High Speed RAID 6 Powered by Custom ASIC Parity Chips High Speed RAID 6 Powered by Custom ASIC Parity Chips Why High Speed RAID 6? Winchester Systems has developed High Speed
enabling Ultra-High Bandwidth Scalable SSDs with HLnand
www.hlnand.com enabling Ultra-High Bandwidth Scalable SSDs with HLnand May 2013 2 Enabling Ultra-High Bandwidth Scalable SSDs with HLNAND INTRODUCTION Solid State Drives (SSDs) are available in a wide
Fault Tolerance & Reliability CDA 5140. Chapter 3 RAID & Sample Commercial FT Systems
Fault Tolerance & Reliability CDA 5140 Chapter 3 RAID & Sample Commercial FT Systems - basic concept in these, as with codes, is redundancy to allow system to continue operation even if some components
Advanced Knowledge and Understanding of Industrial Data Storage
Dec. 3 rd 2013 Advanced Knowledge and Understanding of Industrial Data Storage By Jesse Chuang, Senior Software Manager, Advantech With the popularity of computers and networks, most enterprises and organizations
Solid State Drives Data Reliability and Lifetime. Abstract
Solid State Drives Data Reliability and Lifetime White Paper Alan R. Olson & Denis J. Langlois April 7, 2008 Abstract The explosion of flash memory technology has dramatically increased storage capacity
SLC vs. MLC: An Analysis of Flash Memory
SLC vs. MLC: An Analysis of Flash Memory Examining the Quality of Memory: Understanding the Differences between Flash Grades Table of Contents Abstract... 3 Introduction... 4 Flash Memory Explained...
an analysis of RAID 5DP
an analysis of RAID 5DP a qualitative and quantitative comparison of RAID levels and data protection hp white paper for information about the va 7000 series and periodic updates to this white paper see
Comparison of NAND Flash Technologies Used in Solid- State Storage
An explanation and comparison of SLC and MLC NAND technologies August 2010 Comparison of NAND Flash Technologies Used in Solid- State Storage By Shaluka Perera IBM Systems and Technology Group Bill Bornstein
Industrial Flash Storage Module
April 9, 2012 Version 1. 1 Industrial Flash Storage Module Author: Precyan Lee E-mail: [email protected] April 9, 2012 Version 1. 1 Table of Contents Current Market Trends for Flash Storage...
HP Smart Array Controllers and basic RAID performance factors
Technical white paper HP Smart Array Controllers and basic RAID performance factors Technology brief Table of contents Abstract 2 Benefits of drive arrays 2 Factors that affect performance 2 HP Smart Array
How To Create A Flash-Enabled Storage For Virtual Desktop 2.5 (Vdi) And 3.5D (Vdi) With Nimble Storage
WHITE PAPER Risk-Free Storage for Virtual Desktop Infrastructure (VDI) VDI has unique performance characteristics that legacy storage architectures were never designed to support. This paper explains how
Technical Note Memory Management in NAND Flash Arrays
Technical Note Memory Management in NAND Flash Arrays TN-29-28: Memory Management in NAND Flash Arrays Overview Overview NAND Flash devices have established a strong foothold in solid-state mass storage,
Flash Fabric Architecture
Flash Fabric Architecture Violin Memory s Flash Fabric Architecture is the foundation for the next generation of enterprise storage Version 2.0 Abstract Purpose- built flash technology impacts data center
Operating Systems. RAID Redundant Array of Independent Disks. Submitted by Ankur Niyogi 2003EE20367
Operating Systems RAID Redundant Array of Independent Disks Submitted by Ankur Niyogi 2003EE20367 YOUR DATA IS LOST@#!! Do we have backups of all our data???? - The stuff we cannot afford to lose?? How
Price/performance Modern Memory Hierarchy
Lecture 21: Storage Administration Take QUIZ 15 over P&H 6.1-4, 6.8-9 before 11:59pm today Project: Cache Simulator, Due April 29, 2010 NEW OFFICE HOUR TIME: Tuesday 1-2, McKinley Last Time Exam discussion
NAND Flash Memory Reliability in Embedded Computer Systems
WHITE PAPER NAND Flash Memory Reliability in Embedded Computer Systems Ian Olson INTRODUCTION NAND flash memory named after the NAND logic gates it is constructed from is used for nonvolatile data storage
Enterprise Flash Drive
Enterprise Flash Drive A evolução do armazenamento de dados Tutorial sobre as tecnonologias SSD (Solid State Disk) e sua implantação pela engenharia da EMC, denominado EFD (Enterprise Flash Drive), onde
RAID Made Easy By Jon L. Jacobi, PCWorld
9916 Brooklet Drive Houston, Texas 77099 Phone 832-327-0316 www.safinatechnolgies.com RAID Made Easy By Jon L. Jacobi, PCWorld What is RAID, why do you need it, and what are all those mode numbers that
The Evolving NAND Flash Business Model for SSD. Steffen Hellmold VP BD, SandForce
The Evolving NAND Flash Business Model for SSD Steffen Hellmold VP BD, SandForce Flash Forward: Flash Flash Memory Memory Storage Storage Solutions Solutions Solid State Storage - Vision Solid State Storage
COS 318: Operating Systems. Storage Devices. Kai Li Computer Science Department Princeton University. (http://www.cs.princeton.edu/courses/cos318/)
COS 318: Operating Systems Storage Devices Kai Li Computer Science Department Princeton University (http://www.cs.princeton.edu/courses/cos318/) Today s Topics Magnetic disks Magnetic disk performance
Flash for Databases. September 22, 2015 Peter Zaitsev Percona
Flash for Databases September 22, 2015 Peter Zaitsev Percona In this Presentation Flash technology overview Review some of the available technology What does this mean for databases? Specific opportunities
Disk Storage & Dependability
Disk Storage & Dependability Computer Organization Architectures for Embedded Computing Wednesday 19 November 14 Many slides adapted from: Computer Organization and Design, Patterson & Hennessy 4th Edition,
1 / 25. CS 137: File Systems. Persistent Solid-State Storage
1 / 25 CS 137: File Systems Persistent Solid-State Storage Technology Change is Coming Introduction Disks are cheaper than any solid-state memory Likely to be true for many years But SSDs are now cheap
RAID Overview: Identifying What RAID Levels Best Meet Customer Needs. Diamond Series RAID Storage Array
ATTO Technology, Inc. Corporate Headquarters 155 Crosspoint Parkway Amherst, NY 14068 Phone: 716-691-1999 Fax: 716-691-9353 www.attotech.com [email protected] RAID Overview: Identifying What RAID Levels
Factors rebuilding a degraded RAID
Whitepaper Abstract This whitepaper introduces the procedure rebuilding a degraded RAID. You will find information about RAID levels and their rebuild procedures; rebuild time and its dependent factors.
Solid State Drives. Separating myths from facts
ELECTRONIC COMPONENTS solid state storage MLC performance endurance capacity reliability Solid State Drives Separating myths from facts SSD vs HDD? MLC vs SLC? Determine the right technology for the right
Storage and File Structure
Storage and File Structure Chapter 10: Storage and File Structure Overview of Physical Storage Media Magnetic Disks RAID Tertiary Storage Storage Access File Organization Organization of Records in Files
Solid State Drive Architecture
Solid State Drive Architecture A comparison and evaluation of data storage mediums Tyler Thierolf Justin Uriarte Outline Introduction Storage Device as Limiting Factor Terminology Internals Interface Architecture
Understanding Flash SSD Performance
Understanding Flash SSD Performance Douglas Dumitru CTO EasyCo LLC August 16, 2007 DRAFT Flash based Solid State Drives are quickly becoming popular in a wide variety of applications. Most people think
NAND Flash Architecture and Specification Trends
NAND Flash Architecture and Specification Trends Michael Abraham ([email protected]) NAND Solutions Group Architect Micron Technology, Inc. August 2012 1 Topics NAND Flash Architecture Trends The Cloud
STORAGE SOLID-STATE STORAGE ARRAYS BUYER S CHECKLIST
Managing the information that drives the enterprise STORAGE BUYER S CHECKLIST SOLID-STATE STORAGE ARRAYS storage is fast, cool and consumes little power but it s still pricey, so determining the best place
File System Design and Implementation
Transactions and Reliability Sarah Diesburg Operating Systems CS 3430 Motivation File systems have lots of metadata: Free blocks, directories, file headers, indirect blocks Metadata is heavily cached for
Flash-optimized Data Progression
A Dell white paper Howard Shoobe, Storage Enterprise Technologist John Shirley, Product Management Dan Bock, Product Management Table of contents Executive summary... 3 What is different about Dell Compellent